Sample records for alarm set points

  1. Alarm points for fixed oxygen monitors

    SciTech Connect

    Miller, G.C.

    1987-05-01

    Oxygen concentration monitors were installed in a vault where numerous pipes carried inert cryogens and gases to the Mirror Fusion Test Facility (MFTF-B) experimental vessel at Lawrence Livermore National Laboratory (LLNL). The problems associated with oxygen-monitoring systems and the reasons why such monitors were installed were reviewed. As a result of this review, the MFTF-B monitors were set to sound an evacuation alarm when the oxygen concentration fell below 18%. We chose the 18% alarm criterion to minimize false alarms and to allow time for personnel to escape in an oxygen-deficient environment.

  2. Alarms Philosophy

    SciTech Connect

    White, Karen S; Kasemir, Kay

    2009-01-01

    An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits. In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.

  3. Building Temperature Set Point

    SciTech Connect

    Meincke, Carol L.; Evans, Christopher A.

    2014-09-01

    This white paper provides information and recommendations for an actionable and enforceable corporate policy statement on temperature set points for office and related spaces at Sandia and presents a strategy that balances the need to achieve the energy goals with optimizing employee comfort and productivity.

  4. Point set registration: coherent point drift.

    PubMed

    Myronenko, Andriy; Song, Xubo

    2010-12-01

    Point set registration is a key component in many computer vision tasks. The goal of point set registration is to assign correspondences between two sets of points and to recover the transformation that maps one point set to the other. Multiple factors, including an unknown nonrigid spatial transformation, large dimensionality of point set, noise, and outliers, make the point set registration a challenging problem. We introduce a probabilistic method, called the Coherent Point Drift (CPD) algorithm, for both rigid and nonrigid point set registration. We consider the alignment of two point sets as a probability density estimation problem. We fit the Gaussian mixture model (GMM) centroids (representing the first point set) to the data (the second point set) by maximizing the likelihood. We force the GMM centroids to move coherently as a group to preserve the topological structure of the point sets. In the rigid case, we impose the coherence constraint by reparameterization of GMM centroid locations with rigid parameters and derive a closed form solution of the maximization step of the EM algorithm in arbitrary dimensions. In the nonrigid case, we impose the coherence constraint by regularizing the displacement field and using the variational calculus to derive the optimal transformation. We also introduce a fast algorithm that reduces the method computation complexity to linear. We test the CPD algorithm for both rigid and nonrigid transformations in the presence of noise, outliers, and missing points, where CPD shows accurate results and outperforms current state-of-the-art methods.

  5. Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project

    PubMed Central

    Gomez, Tiffany Michelle; Tarriela, Albert Fajardo; Reed, Charles Calhoun; Paper, Bruce Michael

    2016-01-01

    Background Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians’ attitudes and practices toward clinical alarms and alarm fatigue are scarce. Objective To examine if (1) a change in default alarm settings of the cardiac monitors and (2) in-service nursing education on cardiac monitor use in an ICU would result in reducing alarm rate and in improving nurses’ attitudes and practices toward clinical alarms. Methods This quality improvement project took place in a 20-bed transplant/cardiac ICU with a total of 39 nurses. We implemented a unit-wide change of default alarm settings involving 17 parameters of the cardiac monitors. All nurses received an in-service education on monitor use. Alarm data were collected from the audit log of the cardiac monitors 10 weeks before and 10 weeks after the change in monitors’ parameters. Nurses’ attitudes and practices toward clinical alarms were measured using the Healthcare Technology Foundation National Clinical Alarms Survey, pre- and postintervention. Results Alarm rate was 87.86 alarms/patient day (a total of 64,500 alarms) at the preintervention period compared to 59.18 alarms/patient day (49,319 alarms) postintervention (P=.01). At baseline, Arterial Blood Pressure (ABP), Pair Premature Ventricular Contractions (PVCs), and Peripheral Capillary Oxygen Saturation (SpO2) alarms were the highest. ABP and SpO2 alarms remained among the top three at the postproject period. Out of the 39 ICU nurses, 24 (62%) provided complete pre- and postproject survey questionnaires. Compared to the preintervention survey, no remarkable changes in the postproject period were reported in nurses’ attitudes. Themes in the narrative data were related to poor usability of cardiac monitors and the frequent alarms. The data showed

  6. Multiple Kernel Point Set Registration.

    PubMed

    Nguyen, Thanh Minh; Wu, Q M Jonathan

    2015-12-22

    The finite Gaussian mixture model with kernel correlation is a flexible tool that has recently received attention for point set registration. While there are many algorithms for point set registration presented in the literature, an important issue arising from these studies concerns the mapping of data with nonlinear relationships and the ability to select a suitable kernel. Kernel selection is crucial for effective point set registration. We focus here on multiple kernel point set registration. We make several contributions in this paper. First, each observation is modeled using the Student's t-distribution, which is heavily tailed and more robust than the Gaussian distribution. Second, by automatically adjusting the kernel weights, the proposed method allows us to prune the ineffective kernels. This makes the choice of kernels less crucial. After parameter learning, the kernel saliencies of the irrelevant kernels go to zero. Thus, the choice of kernels is less crucial and it is easy to include other kinds of kernels. Finally, we show empirically that our model outperforms state-of-the-art methods recently proposed in the literature.

  7. Multiple Kernel Point Set Registration.

    PubMed

    Nguyen, Thanh Minh; Wu, Q M Jonathan

    2016-06-01

    The finite Gaussian mixture model with kernel correlation is a flexible tool that has recently received attention for point set registration. While there are many algorithms for point set registration presented in the literature, an important issue arising from these studies concerns the mapping of data with nonlinear relationships and the ability to select a suitable kernel. Kernel selection is crucial for effective point set registration. We focus here on multiple kernel point set registration. We make several contributions in this paper. First, each observation is modeled using the Student's t-distribution, which is heavily tailed and more robust than the Gaussian distribution. Second, by automatically adjusting the kernel weights, the proposed method allows us to prune the ineffective kernels. This makes the choice of kernels less crucial. After parameter learning, the kernel saliencies of the irrelevant kernels go to zero. Thus, the choice of kernels is less crucial and it is easy to include other kinds of kernels. Finally, we show empirically that our model outperforms state-of-the-art methods recently proposed in the literature.

  8. Statistical criteria to set alarm levels for continuous measurements of ground contamination.

    PubMed

    Brandl, A; Jimenez, A D Herrera

    2008-08-01

    In the course of the decommissioning of the ASTRA research reactor at the site of the Austrian Research Centers at Seibersdorf, the operator and licensee, Nuclear Engineering Seibersdorf, conducted an extensive site survey and characterization to demonstrate compliance with regulatory site release criteria. This survey included radiological characterization of approximately 400,000 m(2) of open land on the Austrian Research Centers premises. Part of this survey was conducted using a mobile large-area gas proportional counter, continuously recording measurements while it was moved at a speed of 0.5 ms(-1). In order to set reasonable investigation levels, two alarm levels based on statistical considerations were developed. This paper describes the derivation of these alarm levels and the operational experience gained by detector deployment in the field.

  9. Set point calculations for RAPID project

    SciTech Connect

    HICKMAN, G.L.

    1999-08-27

    The Respond and Pump in Days (RAPID) project was initiated to pump part of the contents of tank 241-SY-101 into tank 241-SY-102. This document establishes the basis for all set points and ranges used in the RAPID project. There are 23 instrument and/or control loops utilized by the RAPID project. These range from the simple indication loop with two components to complex indication, control, and alarm loops with up to eight components. Several loops include safety class elements. This document is intended to describe the loops in full and to provide the basis for each of the element setpoints, ranges and accuracies identified in the RAPID project Master Equipment List (MEL). These values are developed in two steps. First, the base value is identified with reference to the supporting document providing that value. Second, a spreadsheet calculation is performed on each element and loop, utilizing a standard methodology described below, that takes into account known and suspected variance in output and establishes the actual setpoint used on a given element. The results of the spreadsheet are reported directly in this document.

  10. Implementation of Steiner point of fuzzy set.

    PubMed

    Liang, Jiuzhen; Wang, Dejiang

    2014-01-01

    This paper deals with the implementation of Steiner point of fuzzy set. Some definitions and properties of Steiner point are investigated and extended to fuzzy set. This paper focuses on establishing efficient methods to compute Steiner point of fuzzy set. Two strategies of computing Steiner point of fuzzy set are proposed. One is called linear combination of Steiner points computed by a series of crisp α-cut sets of the fuzzy set. The other is an approximate method, which is trying to find the optimal α-cut set approaching the fuzzy set. Stability analysis of Steiner point of fuzzy set is also studied. Some experiments on image processing are given, in which the two methods are applied for implementing Steiner point of fuzzy image, and both strategies show their own advantages in computing Steiner point of fuzzy set.

  11. Comparison of the identification and ease of use of two alarm sound sets by critical and acute care nurses with little or no music training: a laboratory study.

    PubMed

    Atyeo, J; Sanderson, P M

    2015-07-01

    The melodic alarm sound set for medical electrical equipment that was recommended in the International Electrotechnical Commission's IEC 60601-1-8 standard has proven difficult for clinicians to learn and remember, especially clinicians with little prior formal music training. An alarm sound set proposed by Patterson and Edworthy in 1986 might improve performance for such participants. In this study, 31 critical and acute care nurses with less than one year of formal music training identified alarm sounds while they calculated drug dosages. Sixteen nurses used the IEC and 15 used the Patterson-Edworthy alarm sound set. The mean (SD) percentage of alarms correctly identified by nurses was 51.3 (25.6)% for the IEC alarm set and 72.1 (18.8)% for the Patterson-Edworthy alarms (p = 0.016). Nurses using the Patterson-Edworthy alarm sound set reported that it was easier to distinguish between alarm sounds than did nurses using the IEC alarm sound set (p = 0.015). Principles used to construct the Patterson-Edworthy alarm sounds should be adopted for future alarm sound sets.

  12. Neurobiology: Setting the Set Point for Neural Homeostasis.

    PubMed

    Truszkowski, Torrey L S; Aizenman, Carlos D

    2015-12-07

    Neural homeostasis allows neural networks to maintain a dynamic range around a given set point. How this set point is determined remains unknown. New evidence shows that alterations of activity during a critical developmental period can alter the homeostatic set point, resulting in epilepsy-like activity.

  13. Set point calculations for RAPID project

    SciTech Connect

    HICKMAN, G.L.

    1999-11-19

    This change modifies accuracies of the water skid temperature indicators and controllers TIC-410. TI-412, TI-413, TIC-413, TIC-414, TIC-415. Acknowledges ability to calibrate PQIT-367 and modifies the accuracy of that instrument loop. Adjusts the allowable dilution dater temperature from 110-130F to 102-130F based on PCP Rev.2 and adjusts alarm and other points to reflect that change. Removes revision numbers for all references. Numerous additional changes (fixing typos, more detailed explanations etc.) throughout.

  14. A Novel Enuresis Alarm for Toilet Training Students with Intellectual Disability: An Initial Evaluation in a School Setting

    ERIC Educational Resources Information Center

    Mruzek, Daniel W.; McAleavey, Stephen; Engel, Suzanne; Smith, Tristram

    2016-01-01

    In this study, a novel enuresis alarm device using a miniaturized radio frequency module and disposable sensors made with inexpensive conductive ink was used to teach toilet use for urination with three participants with severe intellectual disability (two males and one female; aged 7-15 years) in a private special education school setting. At…

  15. Remote Monitor Alarm System

    NASA Technical Reports Server (NTRS)

    Stute, Robert A. (Inventor); Galloway, F. Houston (Inventor); Medelius, Pedro J. (Inventor); Swindle, Robert W. (Inventor); Bierman, Tracy A. (Inventor)

    1996-01-01

    A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

  16. Ocular stability and set-point adaptation.

    PubMed

    Zee, D S; Jareonsettasin, P; Leigh, R J

    2017-04-19

    A fundamental challenge to the brain is how to prevent intrusive movements when quiet is needed. Unwanted limb movements such as tremor impair fine motor control and unwanted eye drifts such as nystagmus impair vision. A stable platform is also necessary to launch accurate movements. Accordingly, nature has designed control systems with agonist (excitation) and antagonist (inhibition) muscle pairs functioning in push-pull, around a steady level of balanced tonic activity, the set-point Sensory information can be organized similarly, as in the vestibulo-ocular reflex, which generates eye movements that compensate for head movements. The semicircular canals, working in coplanar pairs, one in each labyrinth, are reciprocally excited and inhibited as they transduce head rotations. The relative change in activity is relayed to the vestibular nuclei, which operate around a set-point of stable balanced activity. When a pathological imbalance occurs, producing unwanted nystagmus without head movement, an adaptive mechanism restores the proper set-point and eliminates the nystagmus. Here we used 90 min of continuous 7 T magnetic field labyrinthine stimulation (MVS) in normal humans to produce sustained nystagmus simulating vestibular imbalance. We identified multiple time-scale processes towards a new zero set-point showing that MVS is an excellent paradigm to investigate the neurobiology of set-point adaptation.This article is part of the themed issue 'Movement suppression: brain mechanisms for stopping and stillness'.

  17. Remote temperature-set-point controller

    DOEpatents

    Burke, William F.; Winiecki, Alan L.

    1986-01-01

    An instrument for carrying out mechanical strain tests on metallic samples with the addition of an electrical system for varying the temperature with strain, the instrument including opposing arms and associated equipment for holding a sample and varying the mechanical strain on the sample through a plurality of cycles of increasing and decreasing strain within predetermined limits, circuitry for producing an output signal representative of the strain during the tests, apparatus including a set point and a coil about the sample for providing a controlled temperature in the sample, and circuitry interconnected between the strain output signal and set point for varying the temperature of the sample linearly with strain during the tests.

  18. Confidence Sets for a Change-Point.

    DTIC Science & Technology

    1986-10-01

    probability credible set for j. In fact, even without the explicit evaluation in (1), one knows from a general theorem of Stein (1965) and Hora and...confidence sets with smallest expected measure, Ann. Statist. , 10, 1283-94. Hora , R. B. and Buehler, R. J. (1966), Fiducial theory and invariant...simple cumulative sum type statistic for the change-point problem -’-"C with zero -one observations, Biometrika 67, 79-84. Raferty, A. E. and Akman, V

  19. Criticality accident alarm system

    SciTech Connect

    Malenfant, R.E.

    1991-01-01

    The American National Standard ANSI/ANS-8.3-1986, Criticality Accident Alarm System provides guidance for the establishment and maintenance of an alarm system to initiate personnel evacuation in the event of inadvertent criticality. In addition to identifying the physical features of the components of the system, the characteristics of accidents of concern are carefully delineated. Unfortunately, this ANSI Standard has led to considerable confusion in interpretation, and there is evidence that the minimum accident of concern'' may not be appropriate. Furthermore, although intended as a guide, the provisions of the standard are being rigorously applied, sometimes with interpretations that are not consistent. Although the standard is clear in the use of absorbed dose in free air of 20 rad, at least one installation has interpreted the requirement to apply to dose in soft tissue. The standard is also clear in specifying the response to both neutrons and gamma rays. An assembly of uranyl fluoride enriched to 5% {sup 235}U was operated to simulate a potential accident. The dose, delivered in a free run excursion 2 m from the surface of the vessel, was greater than 500 rad, without ever exceeding a rate of 20 rad/min, which is the set point for activating an alarm that meets the standard. The presence of an alarm system would not have prevented any of the five major accidents in chemical operations nor is it absolutely certain that the alarms were solely responsible for reducing personnel exposures following the accident. Nevertheless, criticality alarm systems are now the subject of great effort and expense. 13 refs.

  20. Set point calculations for RAPID project

    SciTech Connect

    HICKMAN, G.L.

    1999-10-18

    The Respond and Pump in Days (RAPID) project was initiated to pump part of the contents of tank 241-SY-101 into tank 241-SY-102. This document establishes the basis for all set points and ranges used in the RAPID project.

  1. Medical audible alarms: a review

    PubMed Central

    Edworthy, Judy

    2013-01-01

    Objectives This paper summarizes much of the research that is applicable to the design of auditory alarms in a medical context. It also summarizes research that demonstrates that false alarm rates are unacceptably high, meaning that the proper application of auditory alarm design principles are compromised. Target audience Designers, users, and manufacturers of medical information and monitoring systems that indicate when medical or other parameters are exceeded and that are indicated by an auditory signal or signals. Scope The emergence of alarms as a ‘hot topic’; an outline of the issues and design principles, including IEC 60601-1-8; the high incidence of false alarms and its impact on alarm design and alarm fatigue; approaches to reducing alarm fatigue; alarm philosophy explained; urgency in audible alarms; different classes of sound as alarms; heterogeneity in alarm set design; problems with IEC 60601-1-8 and ways of approaching this design problem. PMID:23100127

  2. Remote temperature-set-point controller

    DOEpatents

    Burke, W.F.; Winiecki, A.L.

    1984-10-17

    An instrument is described for carrying out mechanical strain tests on metallic samples with the addition of means for varying the temperature with strain. The instrument includes opposing arms and associated equipment for holding a sample and varying the mechanical strain on the sample through a plurality of cycles of increasing and decreasing strain within predetermined limits, circuitry for producing an output signal representative of the strain during the tests, apparatus including a a set point and a coil about the sample for providing a controlled temperature in the sample, and circuitry interconnected between the strain output signal and set point for varying the temperature of the sample linearly with strain during the tests.

  3. False alarm reduction in critical care.

    PubMed

    Clifford, Gari D; Silva, Ikaro; Moody, Benjamin; Li, Qiao; Kella, Danesh; Chahin, Abdullah; Kooistra, Tristan; Perry, Diane; Mark, Roger G

    2016-08-01

    High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 PhysioNet/Computing in Cardiology Challenge provides a set of 1250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A total of 750 data segments were made available for training and 500 were held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program's performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year's Challenge. This editorial reviews the background issues for this challenge, the design of the challenge itself, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement. Additionally we make some recommendations for future changes in the field of patient monitoring as a result of the Challenge.

  4. Cold Vacuum Drying (CVD) Set Point Determination

    SciTech Connect

    PHILIPP, B.L.

    2000-01-12

    This document provides the calculations used to determine the error of safety class signals used for the CVD process These errors are used with the Parameter limits to arrive at the initial set point. The Safety Class Instrumentation and Control (SCIC) system provides active detection and response to process anomalies that, if unmitigated would result in a safety event. Specifically actuation of the SCIC system includes two portions. The portion which isolates the MCO and initiates the safety-class helium (SCHe) purge, and the portion which detects and stops excessive heat input to the MCO on high tempered water MCO inlet temperature. For the MCO isolation and purge the SCIC receives signals from MCO pressure (both positive pressure and vacuum) helium flow rate, bay high temperature switches, seismic trips and time under vacuum trips.

  5. Functional relationship-based alarm processing

    DOEpatents

    Corsberg, D.R.

    1987-04-13

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). 11 figs.

  6. Understanding Clinical Alarm Safety.

    PubMed

    Lukasewicz, Carol L; Mattox, Elizabeth Andersson

    2015-08-01

    Patient safety organizations and health care accreditation agencies recognize the significance of clinical alarm hazards. The Association for the Advancement of Medical Instrumentation, a nonprofit organization focused on development and use of safe and effective medical equipment, identifies alarm management as a major issue for health care organizations. ECRI Institute, a nonprofit organization that researches approaches for improving patient safety and quality of care, identifies alarm hazards as the most significant of the "Top Ten Health Technology Hazards" for 2014. A new Joint Commission National Patient Safety Goal focusing on clinical alarm safety contains new requirements for accredited hospitals to be fully implemented by 2016. Through a fictional unfolding case study, this article reviews selected contributing factors to clinical alarm hazards present in inpatient, high-acuity settings. Understanding these factors improves contributions by nurses to clinical alarm safety practice.

  7. On the structure of the set of coincidence points

    NASA Astrophysics Data System (ADS)

    Arutyunov, A. V.; Gel'man, B. D.

    2015-03-01

    We consider the set of coincidence points for two maps between metric spaces. Cardinality, metric and topological properties of the coincidence set are studied. We obtain conditions which guarantee that this set (a) consists of at least two points; (b) consists of at least n points; (c) contains a countable subset; (d) is uncountable. The results are applied to study the structure of the double point set and the fixed point set for multivalued contractions. Bibliography: 12 titles.

  8. Cold Vacuum Drying (CVD) Set Point Determination

    SciTech Connect

    PHILIPP, B.L.

    2000-09-04

    oxygen ingress unless a purge of adequate volume has been completed. During bulk water draining, the MCO must remain above atmospheric pressure.) (7) Seismic event of sufficient magnitude is detected. (Trip point is below the Uniform Building Code levels). Setpoint determination is required for trips C through H. Sensor error determination for additional safety-significant sensors used by the HVAC system or the SCHe system are also required.

  9. Improved process control alarm operation.

    PubMed

    Bristol, E H

    2001-01-01

    Alarms are the main connection from the automation to the operator, when addressing process operation outside of its normal function. They are often as much a source of operator overload and consternation as help. Better engineering of the relative role of the operator and automation would materially help overcome the difficulties. Expert systems have been proposed as a solution. But Expert systems are really another form of automation. There remains that aspect of the alarms, which must address our inability to cover and understand a possibly larger domain of the operation not appropriate to traditional controls or present-day automation. Appropriate tools for this domain must support operator discretion and initiative. The paper suggests a set of such general, computer science based, tools requiring only the most basic configuration. They are viewed as implemented on top of those properly detailed alarm displays and interlocks, which reflect the more formal plant operating policies. They include: (a) Various forms of alarm logging and trending; (b) Short, automatically generated, word summaries of alarm activity, which allow low level data to propagate to the highest levels, including: one word and priority summaries; (c) Causal alarm pattern analyses that help the operator to predict or diagnose alarm behavior; (d) Automatic adaptation of alarms and alarm limits to varying process situations; (e) Uniform use of alarm policies to simplify alarm configuration.

  10. Functional relationship-based alarm processing

    DOEpatents

    Corsberg, Daniel R.

    1988-01-01

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously oupdated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on caussal factors between two alarms); (3) required action (system response or action) expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.

  11. Functional relationship-based alarm processing system

    DOEpatents

    Corsberg, Daniel R.

    1989-01-01

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.

  12. Functional relationship-based alarm processing system

    DOEpatents

    Corsberg, D.R.

    1988-04-22

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary. 12 figs.

  13. The PhysioNet/Computing in Cardiology Challenge 2015: Reducing False Arrhythmia Alarms in the ICU.

    PubMed

    Clifford, Gari D; Silva, Ikaro; Moody, Benjamin; Li, Qiao; Kella, Danesh; Shahin, Abdullah; Kooistra, Tristan; Perry, Diane; Mark, Roger G

    2015-09-01

    High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 Physio-Net/Computing in Cardiology Challenge provides a set of 1,250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A collection of 750 data segments was made available for training and a set of 500 was held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program's performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year's Challenge.

  14. Modeling sets of unordered points using highly eccentric ellipses

    NASA Astrophysics Data System (ADS)

    Gerogiannis, Demetrios; Nikou, Christophoros; Likas, Aristidis

    2014-12-01

    An algorithm for modeling a set of unordered two-dimensional points by line segments is presented. The points are modeled by highly eccentric ellipses, and line segments are extracted by the major axes of these elongated ellipses. At first, a single ellipse is fitted to points which is then iteratively split to a large number of highly eccentric ellipses to cover the set of points. Then, a merge process follows in order to combine neighboring ellipses with almost collinear major axes to reduce the complexity of the model. Experimental results on various databases show that the proposed scheme is an efficient technique for modeling unordered sets of points and shapes by line segments. A computer vision application of the method is also presented regarding the detection of retinal fundus image features, such as end-points, junctions, and crossovers.

  15. a Description of the Sets of Lebesgue Points and Points of Summability of a Fourier Series

    NASA Astrophysics Data System (ADS)

    D'yachkov, A. M.

    1993-02-01

    The set of Lebesgue points of a locally integrable function on N-dimensional Euclidean space \\mathbf{R}^N, N\\geq1, is an F_{\\sigma\\delta}-set of full measure. In this article it is shown that every F_{\\sigma\\delta}-set of full measure is the set of Lebesgue points of some measurable bounded function, and, further, that a set with these properties is the set of points of convergence and nontangential (stable) convergence of a singular integral of convolution type: \\displaystyle \\varphi_\\varepsilon*f(x),\\quad \\varphi_\\varepsilon(t)=\\varepsilon^{-N}\\varphi(t/\\varepsilon)\\in L(\\mathbf{R}^N), \\quad\\varepsilon\\to+0,for some measurable bounded function f. On the basis of this result the set of points of summability of a multiple Fourier series by methods of Abel, Riesz, and Picard types is described.

  16. The triangular maps with closed sets of periodic points

    NASA Astrophysics Data System (ADS)

    Kupka, Jiri

    2006-07-01

    In a recent paper we provided a characterization of triangular maps of the square, i.e., maps given by F(x,y)=(f(x),gx(y)), satisfying condition (P1) that any chain recurrent point is periodic. For continuous maps of the interval, there is a list of 18 other conditions equivalent to (P1), including (P2) that there is no infinite [omega]-limit set, (P3) that the set of periodic points is closed and (P4) that any regularly recurrent point is periodic, for instance. We provide an almost complete classification among these conditions for triangular maps, improve a result given by C. Arteaga [C. Arteaga, Smooth triangular maps of the square with closed set of periodic points, J. Math. Anal. Appl. 196 (1995) 987-997] and state an open problem concerning minimal sets of the triangular maps. The paper solves partially a problem formulated by A.N. Sharkovsky in the eighties. The mentioned open problem, the validity of (P4) => (P3), is related to the question whether some regularly recurrent point lies in the fibres over an f-minimal set possessing a regularly recurrent point. We answered this question in the positive for triangular maps with nondecreasing fiber maps. Consequently, the classification is completed for monotone triangular maps.

  17. Adjustable electronic load-alarm relay

    DOEpatents

    Mason, Charles H.; Sitton, Roy S.

    1976-01-01

    This invention is an improved electronic alarm relay for monitoring the current drawn by an AC motor or other electrical load. The circuit is designed to measure the load with high accuracy and to have excellent alarm repeatability. Chattering and arcing of the relay contacts are minimal. The operator can adjust the set point easily and can re-set both the high and the low alarm points by means of one simple adjustment. The relay includes means for generating a signal voltage proportional to the motor current. In a preferred form of the invention a first operational amplifier is provided to generate a first constant reference voltage which is higher than a preselected value of the signal voltage. A second operational amplifier is provided to generate a second constant reference voltage which is lower than the aforementioned preselected value of the signal voltage. A circuit comprising a first resistor serially connected to a second resistor is connected across the outputs of the first and second amplifiers, and the junction of the two resistors is connected to the inverting terminal of the second amplifier. Means are provided to compare the aforementioned signal voltage with both the first and second reference voltages and to actuate an alarm if the signal voltage is higher than the first reference voltage or lower than the second reference voltage.

  18. Point Set Registration via Particle Filtering and Stochastic Dynamics

    PubMed Central

    Sandhu, Romeil; Dambreville, Samuel; Tannenbaum, Allen

    2013-01-01

    In this paper, we propose a particle filtering approach for the problem of registering two point sets that differ by a rigid body transformation. Typically, registration algorithms compute the transformation parameters by maximizing a metric given an estimate of the correspondence between points across the two sets of interest. This can be viewed as a posterior estimation problem, in which the corresponding distribution can naturally be estimated using a particle filter. In this work, we treat motion as a local variation in pose parameters obtained by running a few iterations of a certain local optimizer. Employing this idea, we introduce stochastic motion dynamics to widen the narrow band of convergence often found in local optimizer approaches for registration. Thus, the novelty of our method is threefold: First, we employ a particle filtering scheme to drive the point set registration process. Second, we present a local optimizer that is motivated by the correlation measure. Third, we increase the robustness of the registration performance by introducing a dynamic model of uncertainty for the transformation parameters. In contrast with other techniques, our approach requires no annealing schedule, which results in a reduction in computational complexity (with respect to particle size) as well as maintains the temporal coherency of the state (no loss of information). Also unlike some alternative approaches for point set registration, we make no geometric assumptions on the two data sets. Experimental results are provided that demonstrate the robustness of the algorithm to initialization, noise, missing structures, and/or differing point densities in each set, on several challenging 2D and 3D registration scenarios. PMID:20558877

  19. Unemployment alters the set point for life satisfaction.

    PubMed

    Lucas, Richard E; Clark, Andrew E; Georgellis, Yannis; Diener, Ed

    2004-01-01

    According to set-point theories of subjective well-being, people react to events but then return to baseline levels of happiness and satisfaction over time. We tested this idea by examining reaction and adaptation to unemployment in a 15-year longitudinal study of more than 24,000 individuals living in Germany. In accordance with set-point theories, individuals reacted strongly to unemployment and then shifted back toward their baseline levels of life satisfaction. However, on average, individuals did not completely return to their former levels of satisfaction, even after they became reemployed. Furthermore, contrary to expectations from adaptation theories, people who had experienced unemployment in the past did not react any less negatively to a new bout of unemployment than did people who had not been previously unemployed. These results suggest that although life satisfaction is moderately stable over time, life events can have a strong influence on long-term levels of subjective well-being.

  20. Computational investigations of low-discrepancy point sets

    NASA Technical Reports Server (NTRS)

    Warnock, T. T.

    1971-01-01

    The quasi-Monte Carlo method of integration offers an attractive solution to the problem of evaluating integrals in a large number of dimensions; however, the associated error bounds are difficult to obtain theoretically. Since these bounds are associated with the L2 discrepancy of the set of points used in the integration. Numerical calculations of the L2 discrepancy for several types of quasi-Monte Carlo formulae are presented.

  1. A Time-Domain CMOS Oscillator-Based Thermostat with Digital Set-Point Programming

    PubMed Central

    Chen, Chun-Chi; Lin, Shih-Hao

    2013-01-01

    This paper presents a time-domain CMOS oscillator-based thermostat with digital set-point programming [without a digital-to-analog converter (DAC) or external resistor] to achieve on-chip thermal management of modern VLSI systems. A time-domain delay-line-based thermostat with multiplexers (MUXs) was used to substantially reduce the power consumption and chip size, and can benefit from the performance enhancement due to the scaling down of fabrication processes. For further cost reduction and accuracy enhancement, this paper proposes a thermostat using two oscillators that are suitable for time-domain curvature compensation instead of longer linear delay lines. The final time comparison was achieved using a time comparator with a built-in custom hysteresis to generate the corresponding temperature alarm and control. The chip size of the circuit was reduced to 0.12 mm2 in a 0.35-μm TSMC CMOS process. The thermostat operates from 0 to 90 °C, and achieved a fine resolution better than 0.05 °C and an improved inaccuracy of ± 0.6 °C after two-point calibration for eight packaged chips. The power consumption was 30 μW at a sample rate of 10 samples/s. PMID:23385403

  2. A time-domain CMOS oscillator-based thermostat with digital set-point programming.

    PubMed

    Chen, Chun-Chi; Lin, Shih-Hao

    2013-01-29

    This paper presents a time-domain CMOS oscillator-based thermostat with digital set-point programming [without a digital-to-analog converter (DAC) or external resistor] to achieve on-chip thermal management of modern VLSI systems. A time-domain delay-line-based thermostat with multiplexers (MUXs) was used to substantially reduce the power consumption and chip size, and can benefit from the performance enhancement due to the scaling down of fabrication processes. For further cost reduction and accuracy enhancement, this paper proposes a thermostat using two oscillators that are suitable for time-domain curvature compensation instead of longer linear delay lines. The final time comparison was achieved using a time comparator with a built-in custom hysteresis to generate the corresponding temperature alarm and control. The chip size of the circuit was reduced to 0.12 mm2 in a 0.35-mm TSMC CMOS process. The thermostat operates from 0 to 90 °C, and achieved a fine resolution better than 0.05 °C and an improved inaccuracy of ± 0.6 °C after two-point calibration for eight packaged chips. The power consumption was 30 µW at a sample rate of 10 samples/s.

  3. Improved alarm tracking for better accountability

    SciTech Connect

    Nemesure, S.; Marr, G.; Shrey, T.; Kling, N.; Hammons, L.; Ingrassia, P.; D'Ottavio, T.

    2011-03-28

    An alarm system is a vital component of any accelerator, as it provides a warning that some element of the system is not functioning properly. The severity and age of the alarm may sometimes signify whether urgent or deferred attention is required. For example, older alarms may be given a lower priority if an assumption is made that someone else is already investigating it, whereas those of higher severity or alarms that are more current may indicate the need for an immediate response. The alarm history also provides valuable information regarding the functionality of the overall system, thus careful tracking of these data is likely to improve response time, remove uncertainty about the current status and assist in the ability to promptly respond to the same warning/trigger in the future. Since one goal of every alarm display is to be free of alarms, a clear and concise presentation of an alarm along with useful historic annotations can help the end user address the warning more quickly, thus expediting the elimination of such alarm conditions. By defining a discrete set of very specific alarm management states and by utilizing database resources to maintain a complete and easily accessible alarm history, we anticipate facilitated work flow due to more efficient operator response and management of alarms.

  4. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  5. IMPEDANCE ALARM SYSTEM

    DOEpatents

    Cowen, R.G.

    1959-09-29

    A description is given of electric protective systems and burglar alarm systems of the capacitance type in which the approach of an intruder at a place to be protected varies the capacitance in an electric circuit and the change is thereafter communicated to a remote point to actuate an alarm. According to the invention, an astable transitor multi-vibrator has the amplitude at its output voltage controlled by a change in the sensing capacitance. The sensing capacitance is effectively connected between collector and base of one stage of the multivibrator circuit through the detector-to-monitor line. The output of the detector is a small d-c voltage across the detector-to-monitor line. This d- c voltage is amplified and monitored at the other end of the line, where an appropriate alarm is actuated if a sudden change in the voltage occurs. The present system has a high degree of sensitivity and is very difficult to defeat by known techniques.

  6. Robust Point Set Matching for Partial Face Recognition.

    PubMed

    Weng, Renliang; Lu, Jiwen; Tan, Yap-Peng

    2016-03-01

    Over the past three decades, a number of face recognition methods have been proposed in computer vision, and most of them use holistic face images for person identification. In many real-world scenarios especially some unconstrained environments, human faces might be occluded by other objects, and it is difficult to obtain fully holistic face images for recognition. To address this, we propose a new partial face recognition approach to recognize persons of interest from their partial faces. Given a pair of gallery image and probe face patch, we first detect keypoints and extract their local textural features. Then, we propose a robust point set matching method to discriminatively match these two extracted local feature sets, where both the textural information and geometrical information of local features are explicitly used for matching simultaneously. Finally, the similarity of two faces is converted as the distance between these two aligned feature sets. Experimental results on four public face data sets show the effectiveness of the proposed approach.

  7. Stabilization and set-point regulation of underactuated mechanical systems

    NASA Astrophysics Data System (ADS)

    Loccufier, Mia

    2016-09-01

    Mechanical systems are referred to as underactuated if the number of independent actuators are fewer than the number of degrees of freedom, a general encountered problem in engineering applications. The considered mechanical systems belong to the class of Euler- Lagrange systems where both kinetic energy and potential energy are modeled in their most general form and energy dissipation is modeled according to the dissipation function of Rayleigh, i.e. viscous damping forces are assumed. The control objectives are stabilization and set-point regulation. The structure of the controller is a parallel combination of static output feedback with dynamic output feedback where nonlinear amplifiers are included. An energy based approach with Liapunov functions and the Kalman-Yacubovich-Popov main lemma yields alternative stability theorems. A number of conditions are introduced with respect to the controller's structure in order to guarantee stability. However, sufficient design freedom is left to choose a proper tuning principle and obtain the specified control objectives such as fast convergence to a set-point combined with disturbance rejection. A restriction on the control input energy can be incorporated as well. The applicability of the method will be illustrated with planar manipulators. The main contribution is that a methodology is developed which incorporates many controllers and tuning facilities.

  8. Systematic review of physiologic monitor alarm characteristics and pragmatic interventions to reduce alarm frequency

    PubMed Central

    Paine, Christine Weirich; Goel, Veena V.; Ely, Elizabeth; Stave, Christopher D.; Stemler, Shannon; Zander, Miriam; Bonafide, Christopher P.

    2016-01-01

    Background Alarm fatigue from frequent nonactionable physiologic monitor alarms is frequently named as a threat to patient safety. Purpose To critically examine the available literature relevant to alarm fatigue. Data Sources Articles published in English, Spanish, or French between January 1980 and April 2015 indexed in PubMed, CINAHL, Scopus, Cochrane Library, Google Scholar, and ClinicalTrials.gov. Study Selection Articles focused on hospital physiologic monitor alarms addressing any of the following: 1) the proportion of alarms that are actionable, 2) the relationship between alarm exposure and nurse response time, and 3) the effectiveness of interventions in reducing alarm frequency. Data Extraction We extracted data on setting, collection methods, proportion of alarms determined to be actionable, nurse response time, and associations between interventions and alarm rates. Data Synthesis Our search produced 24 observational studies focused on alarm characteristics and response time and 8 studies evaluating interventions. Actionable alarm proportion ranged from <1% to 36% across a range of hospital settings. Two studies showed relationships between high alarm exposure and longer nurse response time. Most intervention studies included multiple components implemented simultaneously. While studies varied widely, and many had high risk of bias, promising but still unproven interventions include widening alarm parameters, instituting alarm delays, and using disposable electrocardiographic wires or frequently changed electrocardiographic electrodes. Conclusions Physiologic monitor alarms are commonly nonactionable, and evidence supporting the concept of alarm fatigue is emerging. Several interventions have the potential to reduce alarms safely, but more rigorously designed studies with attention to possible unintended consequences are needed. PMID:26663904

  9. The PhysioNet/Computing in Cardiology Challenge 2015: Reducing False Arrhythmia Alarms in the ICU

    PubMed Central

    Clifford, Gari D; Silva, Ikaro; Moody, Benjamin; Li, Qiao; Kella, Danesh; Shahin, Abdullah; Kooistra, Tristan; Perry, Diane; Mark, Roger G.

    2016-01-01

    High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 Physio-Net/Computing in Cardiology Challenge provides a set of 1,250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A collection of 750 data segments was made available for training and a set of 500 was held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program’s performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year’s Challenge. PMID:27331073

  10. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, A.; Moses, H. R.

    2016-01-01

    Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were

  11. T-Farm complex alarm upgrades

    SciTech Connect

    Roberts, J.B.

    1995-01-01

    The alarm and controls associated with the T, TX, and TY farms are located in the 242-T control room. The design data for replacement and upgrades of the alarm panels is in this document. This task was canceled previous to the 90% design review point.

  12. Bed exit alarms.

    PubMed

    2004-09-01

    Bed-exit alarms alert caregivers that a patient who should not get out of bed unassisted is doing so. These alarms can help reduce the likelihood of falls and can promote speedy assistance to patients who have already fallen. But as we described in our May 2004 Guidance Article on bed-exit alarms, they don't themselves prevent falls. They are only effective if used as part of an overall fall-prevention program and with a clear understanding of their limitations. This Evaluation examines the effectiveness of 16 bed-exit alarms from seven suppliers. Our ratings focus primarily on each product's reliability in detecting bed-exit events and alerting caregivers, its ability to minimize nuisance alarms (alarms that sound even though the patient isn't leaving the bed or that sound while a caregiver is helping the patient to leave the bed), and its resistance to deliberate or inadvertent tampering. Twelve of the products use pressure-sensor-activated alarms (mainly sensor pads placed on or under the mattress); three use a cord that can attach to the patient's garment, alarming if the cord is pulled loose from the control unit; and one is a position-sensitive alarm attached to a leg cuff. All the products reliably detect attempted or successful bed exits. But they vary greatly in how effectively they alert staff, minimize nuisance alarms, and resist tampering. Ease of use and battery performance also vary for many units. Of the pressure-sensor units, three are rated Preferred. Those units meet most of our criteria and have no significant disadvantages. Five of the other pressure-sensor products are Acceptable, and the remaining four are Not Recommended. All three cord-activated alarms are rated Acceptable, as is the patient-worn alarm.

  13. On Motivating Operations at the Point of Online Purchase Setting

    ERIC Educational Resources Information Center

    Fagerstrom, Asle; Arntzen, Erik

    2013-01-01

    Consumer behavior analysis can be applied over a wide range of economic topics in which the main focus is the contingencies that influence the behavior of the economic agent. This paper provides an overview on the work that has been done on the impact from motivating operations at the point of online purchase situation. Motivating operations, a…

  14. Registration of 2D point sets by complex translation and rotation operations.

    PubMed

    Sahin, Ismet

    2010-01-01

    Alignment of two sets containing two dimensional vectors (2D points) constitutes an important problem in medical imaging, remote sensing, and computer vision. We assume that the points in one set, called the transformed set, are constructed by translating and rotating the points in the other set, called the original set. The points in both sets are represented by complex numbers. In order to translate and then rotate a point, we add a complex constant and then multiply by a complex exponential respectively. We construct a cost function which tries to achieve the least-squares differences between a given transformed set and the set containing transformed points with respect to optimization parameters. We implement the Newton-Raphson optimization algorithm with polynomial line search in order to minimize this cost function. Simulation results with multiple datasets demonstrate that the proposed method aligns two sets efficiently and reliably.

  15. Turning point sets the stage for emergency preparedness planning.

    PubMed

    Bekemeier, Betty; Dahl, Jan

    2003-01-01

    Nearly a billion dollars were made available to state health departments through federal grants in the spring of 2002 for public health emergency preparedness plans. Twenty-one states had already been participating for some years in The Robert Wood Johnson Foundation's Turning Point Initiative. This article illustrates how earlier practice and experience in developing cross-sector collaborations and institutionalizing a model of broad-based partnerships for public health decision making can increase effectiveness and efficiency in responding to a call for action around an emergency.

  16. Personal Alarm System

    SciTech Connect

    2015-04-17

    Software that runs on smartphones and desktop web browsers and notifies border officials of radiation alarms. It displays images and data associated with an alarm and provides a variety of reports. DOE had a need for discrete notification. PAS replaces the lights and sounds of a Radiation Portal Monitor.

  17. 78 FR 24816 - Pricing for the 2013 American Eagle West Point Two-Coin Silver Set

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-26

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF THE TREASURY United States Mint Pricing for the 2013 American Eagle West Point Two-Coin Silver Set AGENCY: United... the price of the 2013 American Eagle West Point Two-Coin Silver Set. The coin set will be offered...

  18. VISUAL ALARM SYSTEM

    DOEpatents

    Morris, J.M.

    1958-11-01

    A vlsual alarm system, particularly a system incorporating a gas-fllled diode glow bulb, for indicating a minor alarm and also a major alarm is presented. In operation, the disclosed system responds to a signal indlcative of a caution condition by applying a d-c voltage across the glow bulb to induce a glow at one electrode. If a signal indicative of a critlcal condition is received, the system applies an a-c voltage across tbe glow bulb to produce a glow discharge at each electrode.

  19. Smart smoke alarm

    DOEpatents

    Warmack, Robert J. Bruce; Wolf, Dennis A; Frank, Steven Shane

    2015-04-28

    Methods and apparatus for smoke detection are disclosed. In one embodiment, a smoke detector uses linear discriminant analysis (LDA) to determine whether observed conditions indicate that an alarm is warranted.

  20. Alarm Notification System

    SciTech Connect

    1995-03-12

    AN/EMS, the Alarm Notification Energy Management System, is used to monitor digital sensors in PETC buildings and to notify the safety/security operator by both a video and an audio system when a possibly hazardous condition arises.

  1. Joint Clustering and Component Analysis of Correspondenceless Point Sets: Application to Cardiac Statistical Modeling.

    PubMed

    Gooya, Ali; Lekadir, Karim; Alba, Xenia; Swift, Andrew J; Wild, Jim M; Frangi, Alejandro F

    2015-01-01

    Construction of Statistical Shape Models (SSMs) from arbitrary point sets is a challenging problem due to significant shape variation and lack of explicit point correspondence across the training data set. In medical imaging, point sets can generally represent different shape classes that span healthy and pathological exemplars. In such cases, the constructed SSM may not generalize well, largely because the probability density function (pdf) of the point sets deviates from the underlying assumption of Gaussian statistics. To this end, we propose a generative model for unsupervised learning of the pdf of point sets as a mixture of distinctive classes. A Variational Bayesian (VB) method is proposed for making joint inferences on the labels of point sets, and the principal modes of variations in each cluster. The method provides a flexible framework to handle point sets with no explicit point-to-point correspondences. We also show that by maximizing the marginalized likelihood of the model, the optimal number of clusters of point sets can be determined. We illustrate this work in the context of understanding the anatomical phenotype of the left and right ventricles in heart. To this end, we use a database containing hearts of healthy subjects, patients with Pulmonary Hypertension (PH), and patients with Hypertrophic Cardiomyopathy (HCM). We demonstrate that our method can outperform traditional PCA in both generalization and specificity measures.

  2. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Moses, Haifa

    2016-01-01

    Speech alarms have been used extensively in aviation and included in International Building Codes (IBC) and National Fire Protection Association's (NFPA) Life Safety Code. However, they have not been implemented on space vehicles. Previous studies conducted at NASA JSC showed that speech alarms lead to faster identification and higher accuracy. This research evaluated updated speech and tone alerts in a laboratory environment and in the Human Exploration Research Analog (HERA) in a realistic setup.

  3. On the Number of Generator Sets of the Non-Cubic Symmetry Point Groups.

    ERIC Educational Resources Information Center

    Kouyoumdjian, E. R.

    1983-01-01

    The generator set of a group is the subset of the set of elements of the group. The nature and use of generator sets is discussed, focusing on generator sets for the noncubic symmetry point groups containing one, two, and three symmetry elements. (JN)

  4. The problem of alarm fatigue.

    PubMed

    Tanner, Tanya

    2013-01-01

    Up to 99 percent of alarms sounding on hospital units are false alarms signaling no real danger to patients. These false alarms can lead to alarm fatigue and alarm burden, and may divert health care providers' attention away from significant alarms heralding actual or impending harm. As the health care environment continues to become more dependent upon technological monitoring devices used for patient care, nurses must become aware of the possibility and consequences of alarm fatigue and ways to prevent it from negatively affecting their practice, as well as the possible consequences for patient care.

  5. Clinical Alarms in Intensive Care Units: Perceived Obstacles of Alarm Management and Alarm Fatigue in Nurses

    PubMed Central

    Cho, Ok Min; Lee, Young Whee; Cho, Insook

    2016-01-01

    Objectives The purpose of this descriptive study was to investigate the current situation of clinical alarms in intensive care unit (ICU), nurses' recognition of and fatigue in relation to clinical alarms, and obstacles in alarm management. Methods Subjects were ICU nurses and devices from 48 critically ill patient cases. Data were collected through direct observation of alarm occurrence and questionnaires that were completed by the ICU nurses. The observation time unit was one hour block. One bed out of 56 ICU beds was randomly assigned to each observation time unit. Results Overall 2,184 clinical alarms were counted for 48 hours of observation, and 45.5 clinical alarms occurred per hour per subject. Of these, 1,394 alarms (63.8%) were categorized as false alarms. The alarm fatigue score was 24.3 ± 4.0 out of 35. The highest scoring item was "always get bothered due to clinical alarms". The highest scoring item in obstacles was "frequent false alarms, which lead to reduced attention or response to alarms". Conclusions Nurses reported that they felt some fatigue due to clinical alarms, and false alarms were also obstacles to proper management. An appropriate hospital policy should be developed to reduce false alarms and nurses' alarm fatigue. PMID:26893950

  6. Floating point only SIMD instruction set architecture including compare, select, Boolean, and alignment operations

    DOEpatents

    Gschwind, Michael K.

    2011-03-01

    Mechanisms for implementing a floating point only single instruction multiple data instruction set architecture are provided. A processor is provided that comprises an issue unit, an execution unit coupled to the issue unit, and a vector register file coupled to the execution unit. The execution unit has logic that implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA). The floating point vector registers of the vector register file store both scalar and floating point values as vectors having a plurality of vector elements. The processor may be part of a data processing system.

  7. FIRE ALARM SYSTEM OUTDATED.

    ERIC Educational Resources Information Center

    CHANDLER, L.T.

    AN EFFICIENT FIRE ALARM SYSTEM SHOULD--(1) PROVIDE WARNING OF FIRES THAT START IN HIDDEN OR UNOCCUPIED LOCATIONS, (2) INDICATE WHERE THE FIRE IS, (3) GIVE ADVANCE WARNING TO FACULTY AND ADMINISTRATION SO THAT PANIC AND CONFUSION CAN BE AVOIDED AND ORDERLY EVACUATION OCCUR, (4) AUTOMATICALLY NOTIFY CITY FIRE HEADQUARTERS OF THE FIRE, (5) OPERATE BY…

  8. An Optimal Set of Flesh Points on Tongue and Lips for Speech-Movement Classification

    ERIC Educational Resources Information Center

    Wang, Jun; Samal, Ashok; Rong, Panying; Green, Jordan R.

    2016-01-01

    Purpose: The authors sought to determine an optimal set of flesh points on the tongue and lips for classifying speech movements. Method: The authors used electromagnetic articulographs (Carstens AG500 and NDI Wave) to record tongue and lip movements from 13 healthy talkers who articulated 8 vowels, 11 consonants, a phonetically balanced set of…

  9. Dynamic alarm response procedures

    SciTech Connect

    Martin, J.; Gordon, P.; Fitch, K.

    2006-07-01

    The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache{sup R}, IIS{sup R}, TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphics (SVG), such as Netscape{sup R}, Microsoft Internet Explorer{sup R}, Mozilla Firefox{sup R}, Opera{sup R}, and others. (authors)

  10. Control of ELT false alarms

    NASA Technical Reports Server (NTRS)

    Toth, S.; Gershkoff, I.

    1979-01-01

    The statistics of emergency locator transmitter (ELT) alarms are presented. The primary sources of data include ELT Incident Logs, Service Difficulty Reports, and Frequency Interference Reports. The number of reported and unreported alarms is discussed, as are seasonal variations, duration of ELT transmissions, and cost of silencing. Origin, causes, and possible strategies for reducing the impact of alarms on the aviation community are considered.

  11. You Cannot Always Blame the Equipment for False Alarms

    ERIC Educational Resources Information Center

    Smith, Ray T.

    1976-01-01

    Discusses the need for school administrators to establish definite security objectives before shopping for an electronic alarm system and points out that most problems with alarm systems result from people problems, rather than faulty equipment. (For availability see EA 507 081.) (JG)

  12. Pressurized security barrier and alarm system

    DOEpatents

    Carver, Don W.

    1995-01-01

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder's making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed.

  13. Pressurized security barrier and alarm system

    DOEpatents

    Carver, D.W.

    1995-04-11

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder`s making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed. 7 figures.

  14. Improved detection and false alarm rejection for chemical vapors using passive hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Marinelli, William J.; Miyashiro, Rex; Gittins, Christopher M.; Konno, Daisei; Chang, Shing; Farr, Matt; Perkins, Brad

    2013-05-01

    Two AIRIS sensors were tested at Dugway Proving Grounds against chemical agent vapor simulants. The primary objectives of the test were to: 1) assess performance of algorithm improvements designed to reduce false alarm rates with a special emphasis on solar effects, and 3) evaluate performance in target detection at 5 km. The tests included 66 total releases comprising alternating 120 kg glacial acetic acid (GAA) and 60 kg triethyl phosphate (TEP) events. The AIRIS sensors had common algorithms, detection thresholds, and sensor parameters. The sensors used the target set defined for the Joint Service Lightweight Chemical Agent Detector (JSLSCAD) with TEP substituted for GA and GAA substituted for VX. They were exercised at two sites located at either 3 km or 5 km from the release point. Data from the tests will be presented showing that: 1) excellent detection capability was obtained at both ranges with significantly shorter alarm times at 5 km, 2) inter-sensor comparison revealed very comparable performance, 3) false alarm rates < 1 incident per 10 hours running time over 143 hours of sensor operations were achieved, 4) algorithm improvements eliminated both solar and cloud false alarms. The algorithms enabling the improved false alarm rejection will be discussed. The sensor technology has recently been extended to address the problem of detection of liquid and solid chemical agents and toxic industrial chemical on surfaces. The phenomenology and applicability of passive infrared hyperspectral imaging to this problem will be discussed and demonstrated.

  15. A review of statistical methods for data sets with multiple censoring points

    SciTech Connect

    Gilbert, R.O.

    1995-07-06

    This report reviews and summarizes recent literature on statistical methods for analyzing data sets that are censored by multiple censoring points. This report is organized as follows. Following the introductory comments in Section 2, a brief discussion of detection limits is given in Section 3. Sections 4 and 5 focus on data analysis methods for estimating parameters and testing hypotheses, respectively, when data sets are left censored with multiple censoring points. A list of publications that deal with a variety of other applications for censored data sets is provided in Section 6. Recommendations on future research for developing new or improved tools for statistically analyzing multiple left-censored data sets are provided in Section 7. The list of references is in Section 8.

  16. Neurocomputing model for computation of an approximate convex hull of a set of points and spheres.

    PubMed

    Pal, Srimanta; Bhattacharya, Sabyasachi

    2007-03-01

    In this letter, a two-layer neural network is proposed for computation of an approximate convex hull of a set of given points in 3-D or a set of spheres of different sizes. The algorithm is designed based on an elegant concept-shrinking of a spherical rubber balloon surrounding the set of objects in 3-D. Logically, a set of neurons is orderly placed on a spherical mesh i.e., on a rubber balloon surrounding the objects. Each neuron has a parameter vector associated with its current position. The resultant force of attraction between a neuron and each of the given points/objects, determines the direction of a movement of the neuron lying on the rubber balloon. As the network evolves, the neurons (parameter vectors) approximate the convex hull more and more accurately.

  17. Hypo- and Hyperglycemic Alarms

    PubMed Central

    Howsmon, Daniel; Bequette, B. Wayne

    2015-01-01

    Soon after the discovery that insulin regulates blood glucose by Banting and Best in 1922, the symptoms and risks associated with hypoglycemia became widely recognized. This article reviews devices to warn individuals of impending hypo- and hyperglycemia; biosignals used by these devices include electroencephalography, electrocardiography, skin galvanic resistance, diabetes alert dogs, and continuous glucose monitors (CGMs). While systems based on other technology are increasing in performance and decreasing in size, CGM technology remains the best method for both reactive and predictive alarming of hypo- or hyperglycemia. PMID:25931581

  18. Alarm toe switch

    DOEpatents

    Ganyard, Floyd P.

    1982-01-01

    An alarm toe switch inserted within a shoe for energizing an alarm circuit n a covert manner includes an insole mounting pad into which a miniature reed switch is fixedly molded. An elongated slot perpendicular to the reed switch is formed in the bottom surface of the mounting pad. A permanent cylindrical magnet positioned in the forward portion of the slot with a diameter greater than the pad thickness causes a bump above the pad. A foam rubber block is also positioned in the slot rearwardly of the magnet and holds the magnet in normal inoperative relation. A non-magnetic support plate covers the slot and holds the magnet and foam rubber in the slot. The plate minimizes bending and frictional forces to improve movement of the magnet for reliable switch activation. The bump occupies the knuckle space beneath the big toe. When the big toe is scrunched rearwardly the magnet is moved within the slot relative to the reed switch, thus magnetically activating the switch. When toe pressure is released the foam rubber block forces the magnet back into normal inoperative position to deactivate the reed switch. The reed switch is hermetically sealed with the magnet acting through the wall so the switch assembly S is capable of reliable operation even in wet and corrosive environments.

  19. Robust group-wise rigid registration of point sets using t-mixture model

    NASA Astrophysics Data System (ADS)

    Ravikumar, Nishant; Gooya, Ali; Frangi, Alejandro F.; Taylor, Zeike A.

    2016-03-01

    A probabilistic framework for robust, group-wise rigid alignment of point-sets using a mixture of Students t-distribution especially when the point sets are of varying lengths, are corrupted by an unknown degree of outliers or in the presence of missing data. Medical images (in particular magnetic resonance (MR) images), their segmentations and consequently point-sets generated from these are highly susceptible to corruption by outliers. This poses a problem for robust correspondence estimation and accurate alignment of shapes, necessary for training statistical shape models (SSMs). To address these issues, this study proposes to use a t-mixture model (TMM), to approximate the underlying joint probability density of a group of similar shapes and align them to a common reference frame. The heavy-tailed nature of t-distributions provides a more robust registration framework in comparison to state of the art algorithms. Significant reduction in alignment errors is achieved in the presence of outliers, using the proposed TMM-based group-wise rigid registration method, in comparison to its Gaussian mixture model (GMM) counterparts. The proposed TMM-framework is compared with a group-wise variant of the well-known Coherent Point Drift (CPD) algorithm and two other group-wise methods using GMMs, using both synthetic and real data sets. Rigid alignment errors for groups of shapes are quantified using the Hausdorff distance (HD) and quadratic surface distance (QSD) metrics.

  20. Public Data Set: Control and Automation of the Pegasus Multi-point Thomson Scattering System

    SciTech Connect

    Bodner, Grant M.; Bongard, Michael W.; Fonck, Raymond J.; Reusch, Joshua A.; Rodriguez Sanchez, Cuauhtemoc; Schlossberg, David J.

    2016-08-12

    This public data set contains openly-documented, machine readable digital research data corresponding to figures published in G.M. Bodner et al., 'Control and Automation of the Pegasus Multi-point Thomson Scattering System,' Rev. Sci. Instrum. 87, 11E523 (2016).

  1. PIV study of the wake of a model wind turbine transitioning between operating set points

    NASA Astrophysics Data System (ADS)

    Houck, Dan; Cowen, Edwin (Todd)

    2016-11-01

    Wind turbines are ideally operated at their most efficient tip speed ratio for a given wind speed. There is increasing interest, however, in operating turbines at other set points to increase the overall power production of a wind farm. Specifically, Goit and Meyers (2015) used LES to examine a wind farm optimized by unsteady operation of its turbines. In this study, the wake of a model wind turbine is measured in a water channel using PIV. We measure the wake response to a change in operational set point of the model turbine, e.g., from low to high tip speed ratio or vice versa, to examine how it might influence a downwind turbine. A modified torque transducer after Kang et al. (2010) is used to calibrate in situ voltage measurements of the model turbine's generator operating across a resistance to the torque on the generator. Changes in operational set point are made by changing the resistance or the flow speed, which change the rotation rate measured by an encoder. Single camera PIV on vertical planes reveals statistics of the wake at various distances downstream as the turbine transitions from one set point to another. From these measurements, we infer how the unsteady operation of a turbine may affect the performance of a downwind turbine as its incoming flow. National Science Foundation and the Atkinson Center for a Sustainable Future.

  2. Hysteresis and calcium set-point for the calcium parathyroid hormone relationship in healthy horses.

    PubMed

    Toribio, Ramiro E; Kohn, Catherine W; Sams, Richard A; Capen, Charles C; Rosol, Thomas J

    2003-02-15

    Abnormalities in calcium (Ca(2+)) homeostasis are reported in horses with several pathological conditions; however, there is little information on Ca(2+) regulation in horses. The objectives of the present study were to determine the Ca(2+) set-point in healthy horses, to determine whether the Ca(2+)/parathyroid hormone (PTH) response curves were characterized by hysteresis, and to determine if the order of experimentally induced hypocalcemia or hypercalcemia had an effect on PTH secretion. The Ca(2+) set-point and hysteresis were determined in 12 healthy horses by infusing Na(2)EDTA and calcium gluconate. The Ca(2+) set-point was 1.37 +/- 0.05 mmol/L, which is higher than values reported for humans and dogs (1.0-1.2 mmol/L). Hysteresis was present during hypocalcemia and hypercalcemia. Horses in which hypocalcemia was followed by hypercalcemia secreted more PTH (7440 +/- 740 pmol min/L) than horses in which hypercalcemia was followed by hypocalcemia (5990 +/- 570 pmol min/L). This study has demonstrated that the Ca(2+) set-point in the horse is higher than in other domestic animals and man. We have shown that the Ca(2+)/PTH relationship in horses is sigmoidal and displays hysteresis during both hypocalcemia and hypercalcemia, and that extracellular Ca(2+) concentrations may affect the response of the parathyroid gland to hypocalcemia.

  3. Integrating monitor alarms with laboratory test results to enhance patient deterioration prediction.

    PubMed

    Bai, Yong; Do, Duc H; Harris, Patricia Rae Eileen; Schindler, Daniel; Boyle, Noel G; Drew, Barbara J; Hu, Xiao

    2015-02-01

    Patient monitors in modern hospitals have become ubiquitous but they generate an excessive number of false alarms causing alarm fatigue. Our previous work showed that combinations of frequently co-occurring monitor alarms, called SuperAlarm patterns, were capable of predicting in-hospital code blue events at a lower alarm frequency. In the present study, we extend the conceptual domain of a SuperAlarm to incorporate laboratory test results along with monitor alarms so as to build an integrated data set to mine SuperAlarm patterns. We propose two approaches to integrate monitor alarms with laboratory test results and use a maximal frequent itemsets mining algorithm to find SuperAlarm patterns. Under an acceptable false positive rate FPRmax, optimal parameters including the minimum support threshold and the length of time window for the algorithm to find the combinations of monitor alarms and laboratory test results are determined based on a 10-fold cross-validation set. SuperAlarm candidates are generated under these optimal parameters. The final SuperAlarm patterns are obtained by further removing the candidates with false positive rate>FPRmax. The performance of SuperAlarm patterns are assessed using an independent test data set. First, we calculate the sensitivity with respect to prediction window and the sensitivity with respect to lead time. Second, we calculate the false SuperAlarm ratio (ratio of the hourly number of SuperAlarm triggers for control patients to that of the monitor alarms, or that of regular monitor alarms plus laboratory test results if the SuperAlarm patterns contain laboratory test results) and the work-up to detection ratio, WDR (ratio of the number of patients triggering any SuperAlarm patterns to that of code blue patients triggering any SuperAlarm patterns). The experiment results demonstrate that when varying FPRmax between 0.02 and 0.15, the SuperAlarm patterns composed of monitor alarms along with the last two laboratory test results

  4. An affine point-set and line invariant algorithm for photo-identification of gray whales

    NASA Astrophysics Data System (ADS)

    Chandan, Chandan; Kehtarnavaz, Nasser; Hillman, Gilbert; Wursig, Bernd

    2004-05-01

    This paper presents an affine point-set and line invariant algorithm within a statistical framework, and its application to photo-identification of gray whales (Eschrichtius robustus). White patches (blotches) appearing on a gray whale's left and right flukes (the flattened broad paddle-like tail) constitute unique identifying features and have been used here for individual identification. The fluke area is extracted from a fluke image via the live-wire edge detection algorithm, followed by optimal thresholding of the fluke area to obtain the blotches. Affine point-set and line invariants of the blotch points are extracted based on three reference points, namely the left and right tips and the middle notch-like point on the fluke. A set of statistics is derived from the invariant values and used as the feature vector representing a database image. The database images are then ranked depending on the degree of similarity between a query and database feature vectors. The results show that the use of this algorithm leads to a reduction in the amount of manual search that is normally done by marine biologists.

  5. Generating and executing programs for a floating point single instruction multiple data instruction set architecture

    DOEpatents

    Gschwind, Michael K

    2013-04-16

    Mechanisms for generating and executing programs for a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA) are provided. A computer program product comprising a computer recordable medium having a computer readable program recorded thereon is provided. The computer readable program, when executed on a computing device, causes the computing device to receive one or more instructions and execute the one or more instructions using logic in an execution unit of the computing device. The logic implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA), based on data stored in a vector register file of the computing device. The vector register file is configured to store both scalar and floating point values as vectors having a plurality of vector elements.

  6. Keypoint-based 4-Points Congruent Sets - Automated marker-less registration of laser scans

    NASA Astrophysics Data System (ADS)

    Theiler, Pascal Willy; Wegner, Jan Dirk; Schindler, Konrad

    2014-10-01

    We propose a method to automatically register two point clouds acquired with a terrestrial laser scanner without placing any markers in the scene. What makes this task challenging are the strongly varying point densities caused by the line-of-sight measurement principle, and the huge amount of data. The first property leads to low point densities in potential overlap areas with scans taken from different viewpoints while the latter calls for highly efficient methods in terms of runtime and memory requirements. A crucial yet largely unsolved step is the initial coarse alignment of two scans without any simplifying assumptions, that is, point clouds are given in arbitrary local coordinates and no knowledge about their relative orientation is available. Once coarse alignment has been solved, scans can easily be fine-registered with standard methods like least-squares surface or Iterative Closest Point matching. In order to drastically thin out the original point clouds while retaining characteristic features, we resort to extracting 3D keypoints. Such clouds of keypoints, which can be viewed as a sparse but nevertheless discriminative representation of the original scans, are then used as input to a very efficient matching method originally developed in computer graphics, called 4-Points Congruent Sets (4PCS) algorithm. We adapt the 4PCS matching approach to better suit the characteristics of laser scans. The resulting Keypoint-based 4-Points Congruent Sets (K-4PCS) method is extensively evaluated on challenging indoor and outdoor scans. Beyond the evaluation on real terrestrial laser scans, we also perform experiments with simulated indoor scenes, paying particular attention to the sensitivity of the approach with respect to highly symmetric scenes.

  7. Articulated Non-Rigid Point Set Registration for Human Pose Estimation from 3D Sensors

    PubMed Central

    Ge, Song; Fan, Guoliang

    2015-01-01

    We propose a generative framework for 3D human pose estimation that is able to operate on both individual point sets and sequential depth data. We formulate human pose estimation as a point set registration problem, where we propose three new approaches to address several major technical challenges in this research. First, we integrate two registration techniques that have a complementary nature to cope with non-rigid and articulated deformations of the human body under a variety of poses. This unique combination allows us to handle point sets of complex body motion and large pose variation without any initial conditions, as required by most existing approaches. Second, we introduce an efficient pose tracking strategy to deal with sequential depth data, where the major challenge is the incomplete data due to self-occlusions and view changes. We introduce a visible point extraction method to initialize a new template for the current frame from the previous frame, which effectively reduces the ambiguity and uncertainty during registration. Third, to support robust and stable pose tracking, we develop a segment volume validation technique to detect tracking failures and to re-initialize pose registration if needed. The experimental results on both benchmark 3D laser scan and depth datasets demonstrate the effectiveness of the proposed framework when compared with state-of-the-art algorithms. PMID:26131673

  8. An Optimal Set of Flesh Points on Tongue and Lips for Speech-Movement Classification

    PubMed Central

    Samal, Ashok; Rong, Panying; Green, Jordan R.

    2016-01-01

    Purpose The authors sought to determine an optimal set of flesh points on the tongue and lips for classifying speech movements. Method The authors used electromagnetic articulographs (Carstens AG500 and NDI Wave) to record tongue and lip movements from 13 healthy talkers who articulated 8 vowels, 11 consonants, a phonetically balanced set of words, and a set of short phrases during the recording. We used a machine-learning classifier (support-vector machine) to classify the speech stimuli on the basis of articulatory movements. We then compared classification accuracies of the flesh-point combinations to determine an optimal set of sensors. Results When data from the 4 sensors (T1: the vicinity between the tongue tip and tongue blade; T4: the tongue-body back; UL: the upper lip; and LL: the lower lip) were combined, phoneme and word classifications were most accurate and were comparable with the full set (including T2: the tongue-body front; and T3: the tongue-body front). Conclusion We identified a 4-sensor set—that is, T1, T4, UL, LL—that yielded a classification accuracy (91%–95%) equivalent to that using all 6 sensors. These findings provide an empirical basis for selecting sensors and their locations for scientific and emerging clinical applications that incorporate articulatory movements. PMID:26564030

  9. A Stochastic Approach to Diffeomorphic Point Set Registration With Landmark Constraints

    PubMed Central

    Kolesov, Ivan; Lee, Jehoon; Sharp, Gregory; Vela, Patricio; Tannenbaum, Allen

    2016-01-01

    This work presents a deformable point set registration algorithm that seeks an optimal set of radial basis functions to describe the registration. A novel, global optimization approach is introduced composed of simulated annealing with a particle filter based generator function to perform the registration. It is shown how constraints can be incorporated into this framework. A constraint on the deformation is enforced whose role is to ensure physically meaningful fields (i.e., invertible). Further, examples in which landmark constraints serve to guide the registration are shown. Results on 2D and 3D data demonstrate the algorithm’s robustness to noise and missing information. PMID:26761731

  10. Distributed Computation of the knn Graph for Large High-Dimensional Point Sets

    PubMed Central

    Plaku, Erion; Kavraki, Lydia E.

    2009-01-01

    High-dimensional problems arising from robot motion planning, biology, data mining, and geographic information systems often require the computation of k nearest neighbor (knn) graphs. The knn graph of a data set is obtained by connecting each point to its k closest points. As the research in the above-mentioned fields progressively addresses problems of unprecedented complexity, the demand for computing knn graphs based on arbitrary distance metrics and large high-dimensional data sets increases, exceeding resources available to a single machine. In this work we efficiently distribute the computation of knn graphs for clusters of processors with message passing. Extensions to our distributed framework include the computation of graphs based on other proximity queries, such as approximate knn or range queries. Our experiments show nearly linear speedup with over one hundred processors and indicate that similar speedup can be obtained with several hundred processors. PMID:19847318

  11. Robust set-point regulation for ecological models with multiple management goals.

    PubMed

    Guiver, Chris; Mueller, Markus; Hodgson, Dave; Townley, Stuart

    2016-05-01

    Population managers will often have to deal with problems of meeting multiple goals, for example, keeping at specific levels both the total population and population abundances in given stage-classes of a stratified population. In control engineering, such set-point regulation problems are commonly tackled using multi-input, multi-output proportional and integral (PI) feedback controllers. Building on our recent results for population management with single goals, we develop a PI control approach in a context of multi-objective population management. We show that robust set-point regulation is achieved by using a modified PI controller with saturation and anti-windup elements, both described in the paper, and illustrate the theory with examples. Our results apply more generally to linear control systems with positive state variables, including a class of infinite-dimensional systems, and thus have broader appeal.

  12. Talking Fire Alarms Calm Kids.

    ERIC Educational Resources Information Center

    Executive Educator, 1984

    1984-01-01

    The new microprocessor-based fire alarm systems can help to control smoke movement throughout school buildings by opening vents and doors, identify the burning section, activate voice alarms, provide firefighters with telephone systems during the fire, and release fire-preventing gas. (KS)

  13. Cinacalcet Reduces the Set Point of the PTH-Calcium Curve

    PubMed Central

    Valle, Casimiro; Rodriguez, Mariano; Santamaría, Rafael; Almaden, Yolanda; Rodriguez, Maria E.; Cañadillas, Sagrario; Martin-Malo, Alejandro; Aljama, Pedro

    2008-01-01

    The calcimimetic cinacalcet increases the sensitivity of the parathyroid calcium-sensing receptor to calcium and therefore should produce a decrease in the set point of the parathyroid hormone (PTH)-calcium curve. For investigation of this hypothesis, nine long-term hemodialysis patients with secondary hyperparathyroidism were given cinacalcet for 2 mo, the dosage was titrated per a protocol based on intact PTH and plasma calcium concentrations. Dialysis against low- and high-calcium (0.75 and 1.75 mM) dialysate was used to generate curves describing the relationship between PTH and calcium. Compared with precinacalcet levels, cinacalcet significantly reduced mean serum calcium, intact PTH and whole PTH (wPTH; all P < 0.001). The set points for PTH-calcium curves were significantly reduced, and both maximum and minimum levels of PTH (intact and whole) were significantly decreased. The calcium-mediated inhibition of PTH secretion was more marked after cinacalcet treatment. In addition, cinacalcet shifted the inverse sigmoidal curve of wPTH/non-wPTH ratio versus calcium to the left (i.e., less calcium was required to reduce the wPTH/non-wPTH ratio). In conclusion, cinacalcet increases the sensitivity of the parathyroids to calcium, causing a marked reduction in the set point of the PTH-calcium curve, in hemodialysis patients with secondary hyperparathyroidism. PMID:18632847

  14. Robust CPD Algorithm for Non-Rigid Point Set Registration Based on Structure Information

    PubMed Central

    Peng, Lei; Li, Guangyao; Xiao, Mang; Xie, Li

    2016-01-01

    Recently, the Coherent Point Drift (CPD) algorithm has become a very popular and efficient method for point set registration. However, this method does not take into consideration the neighborhood structure information of points to find the correspondence and requires a manual assignment of the outlier ratio. Therefore, CPD is not robust for large degrees of degradation. In this paper, an improved method is proposed to overcome the two limitations of CPD. A structure descriptor, such as shape context, is used to perform the auxiliary calculation of the correspondence, and the proportion of each GMM component is adjusted by the similarity. The outlier ratio is formulated in the EM framework so that it can be automatically calculated and optimized iteratively. The experimental results on both synthetic data and real data demonstrate that the proposed method described here is more robust to deformation, noise, occlusion, and outliers than CPD and other state-of-the-art algorithms. PMID:26866918

  15. Substation alarm multiplexing system (SAMS)

    SciTech Connect

    ElBadaly, H.; Gaughan, J.; Ward, G.; Amengual, S.

    1996-03-01

    This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creek substation in the Bronx for the purpose of a three month field evaluation.

  16. Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics

    PubMed Central

    Sharma, Shikha; Zapatero-Rodríguez, Julia; Estrela, Pedro; O’Kennedy, Richard

    2015-01-01

    The inability to diagnose numerous diseases rapidly is a significant cause of the disparity of deaths resulting from both communicable and non-communicable diseases in the developing world in comparison to the developed world. Existing diagnostic instrumentation usually requires sophisticated infrastructure, stable electrical power, expensive reagents, long assay times, and highly trained personnel which is not often available in limited resource settings. This review will critically survey and analyse the current lateral flow-based point-of-care (POC) technologies, which have made a major impact on diagnostic testing in developing countries over the last 50 years. The future of POC technologies including the applications of microfluidics, which allows miniaturisation and integration of complex functions that facilitate their usage in limited resource settings, is discussed The advantages offered by such systems, including low cost, ruggedness and the capacity to generate accurate and reliable results rapidly, are well suited to the clinical and social settings of the developing world. PMID:26287254

  17. Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics.

    PubMed

    Sharma, Shikha; Zapatero-Rodríguez, Julia; Estrela, Pedro; O'Kennedy, Richard

    2015-08-13

    The inability to diagnose numerous diseases rapidly is a significant cause of the disparity of deaths resulting from both communicable and non-communicable diseases in the developing world in comparison to the developed world. Existing diagnostic instrumentation usually requires sophisticated infrastructure, stable electrical power, expensive reagents, long assay times, and highly trained personnel which is not often available in limited resource settings. This review will critically survey and analyse the current lateral flow-based point-of-care (POC) technologies, which have made a major impact on diagnostic testing in developing countries over the last 50 years. The future of POC technologies including the applications of microfluidics, which allows miniaturisation and integration of complex functions that facilitate their usage in limited resource settings, is discussed The advantages offered by such systems, including low cost, ruggedness and the capacity to generate accurate and reliable results rapidly, are well suited to the clinical and social settings of the developing world.

  18. A point cloud based pipeline for depth reconstruction from autostereoscopic sets

    NASA Astrophysics Data System (ADS)

    Niquin, Cédric; Prévost, Stéphanie; Remion, Yannick

    2010-02-01

    This is a three step pipeline to construct a 3D mesh of a scene from a set of N images, destined to be viewed on auto-stereoscopic displays. The first step matches the pixels to create a point cloud using a new algorithm based on graph-cuts. It exploits the data redundancy of the N images to ensure the geometric consistency of the scene and to reduce the graph complexity, in order to speed up the computation. It performs an accurate detection of occlusions and its results can then be used in applications like view synthesis. The second step slightly moves the points along the Z-axis to refine the point cloud. It uses a new cost including both occlusion positions and light variations deduced from the matching. The Z values are selected using a dynamic programming algorithm. This step finally generates a point cloud, which is fine enough for applications like augmented reality. From any of the two previously defined point clouds, the last step creates a colored mesh, which is a convenient data structure to be used in graphics APIs. It also generates N depth maps, allowing a comparison between the results of our method with those of other methods.

  19. Touch and gravitropic set-point angle interact to modulate gravitropic growth in roots

    NASA Technical Reports Server (NTRS)

    Massa, G. D.; Gilroy, S.

    2003-01-01

    Plant roots must sense and respond to a variety of environmental stimuli as they grow through the soil. Touch and gravity represent two of the mechanical signals that roots must integrate to elicit the appropriate root growth patterns and root system architecture. Obstacles such as rocks will impede the general downwardly directed gravitropic growth of the root system and so these soil features must be sensed and this information processed for an appropriate alteration in gravitropic growth to allow the root to avoid the obstruction. We show that primary and lateral roots of Arabidopsis do appear to sense and respond to mechanical barriers placed in their path of growth in a qualitatively similar fashion. Both types of roots exhibited a differential growth response upon contacting the obstacle that directed the main axis of elongation parallel to the barrier. This growth habit was maintained until the obstacle was circumvented, at which point normal gravitropic growth was resumed. Thus, the gravitational set-point angle of the primary and lateral roots prior to encountering the barrier were 95 degrees and 136 degrees respectively and after growing off the end of the obstacle identical set-point angles were reinstated. However, whilst tracking across the barrier, quantitative differences in response were observed between these two classes of roots. The root tip of the primary root maintained an angle of 136 degrees to the horizontal as it traversed the barrier whereas the lateral roots adopted an angle of 154 degrees. Thus, this root tip angle appeared dependent on the gravitropic set-point angle of the root type with the difference in tracking angle quantitatively reflecting differences in initial set-point angle. Concave and convex barriers were also used to analyze the response of the root to tracking along a continuously varying surface. The roots maintained the a fairly fixed angle to gravity on the curved surface implying a constant resetting of this tip angle

  20. Go-ICP: A Globally Optimal Solution to 3D ICP Point-Set Registration.

    PubMed

    Yang, Jiaolong; Li, Hongdong; Campbell, Dylan; Jia, Yunde

    2016-11-01

    The Iterative Closest Point (ICP) algorithm is one of the most widely used methods for point-set registration. However, being based on local iterative optimization, ICP is known to be susceptible to local minima. Its performance critically relies on the quality of the initialization and only local optimality is guaranteed. This paper presents the first globally optimal algorithm, named Go-ICP, for Euclidean (rigid) registration of two 3D point-sets under the L2 error metric defined in ICP. The Go-ICP method is based on a branch-and-bound scheme that searches the entire 3D motion space SE(3). By exploiting the special structure of SE(3) geometry, we derive novel upper and lower bounds for the registration error function. Local ICP is integrated into the BnB scheme, which speeds up the new method while guaranteeing global optimality. We also discuss extensions, addressing the issue of outlier robustness. The evaluation demonstrates that the proposed method is able to produce reliable registration results regardless of the initialization. Go-ICP can be applied in scenarios where an optimal solution is desirable or where a good initialization is not always available.

  1. Performance of a Blood Glucose Monitoring System in a Point-of-Care Setting

    PubMed Central

    Ottiger, Cornelia; Gygli, Nicole; Huber, Andreas R.; Fernandez-Tresguerres, Beatriz; Pardo, Scott; Petruschke, Thorsten

    2016-01-01

    This study assesses and demonstrates that CONTOUR® XT-BGMS (CXT-BGMS) complies with the requirements of the German (RiliBÄK) and Swiss (QUALAB) quality control guidelines for point-of-care testing (POCT) and fulfills the ISO15197:2013 accuracy limits criteria under the routine conditions of a hospital point-of care setting. This single-center study was conducted in Switzerland using 105 venous blood samples from hospitalized patients. Each sample was tested in comparison to the hexokinase reference method. Compliance with POCT guidelines was assessed by daily BGMS measurements using control solutions. Accuracy of CXT-BGMS according to ISO limits was 98.41%. All control measurements were within the limits defined by RiliBÄK (within ± 11% of target values and root mean square error [RMSE] within RMSE limits), and QUALAB (within ± 10% of target values). PMID:26989068

  2. Emerging technologies in point-of-care molecular diagnostics for resource-limited settings.

    PubMed

    Peeling, Rosanna W; McNerney, Ruth

    2014-06-01

    Emerging molecular technologies to diagnose infectious diseases at the point at which care is delivered have the potential to save many lives in developing countries where access to laboratories is poor. Molecular tests are needed to improve the specificity of syndromic management, monitor progress towards disease elimination and screen for asymptomatic infections with the goal of interrupting disease transmission and preventing long-term sequelae. In simplifying laboratory-based molecular assays for use at point-of-care, there are inevitable compromises between cost, ease of use and test performance. Despite significant technological advances, many challenges remain for the development of molecular diagnostics for resource-limited settings. There needs to be more advocacy for these technologies to be applied to infectious diseases, increased efforts to lower the barriers to market entry through streamlined and harmonized regulatory approaches, faster policy development for adoption of new technologies and novel financing mechanisms to enable countries to scale up implementation.

  3. Advances in addressing technical challenges of point-of-care diagnostics in resource-limited settings.

    PubMed

    Wang, ShuQi; Lifson, Mark A; Inci, Fatih; Liang, Li-Guo; Sheng, Ye-Feng; Demirci, Utkan

    2016-01-01

    The striking prevalence of HIV, TB and malaria, as well as outbreaks of emerging infectious diseases, such as influenza A (H7N9), Ebola and MERS, poses great challenges for patient care in resource-limited settings (RLS). However, advanced diagnostic technologies cannot be implemented in RLS largely due to economic constraints. Simple and inexpensive point-of-care (POC) diagnostics, which rely less on environmental context and operator training, have thus been extensively studied to achieve early diagnosis and treatment monitoring in non-laboratory settings. Despite great input from material science, biomedical engineering and nanotechnology for developing POC diagnostics, significant technical challenges are yet to be overcome. Summarized here are the technical challenges associated with POC diagnostics from a RLS perspective and the latest advances in addressing these challenges are reviewed.

  4. Advances in addressing technical challenges of point-of-care diagnostics in resource-limited settings

    PubMed Central

    Wang, ShuQi; Lifson, Mark A.; Inci, Fatih; Liang, Li-Guo; Sheng, Ye-Feng; Demirci, Utkan

    2016-01-01

    The striking prevalence of HIV, TB and malaria, as well as outbreaks of emerging infectious diseases, such as influenza A (H7N9), Ebola and MERS, poses great challenges for patient care in resource-limited settings (RLS). However, advanced diagnostic technologies cannot be implemented in RLS largely due to economic constraints. Simple and inexpensive point-of-care (POC) diagnostics, which rely less on environmental context and operator training, have thus been extensively studied to achieve early diagnosis and treatment monitoring in non-laboratory settings. Despite great input from material science, biomedical engineering and nanotechnology for developing POC diagnostics, significant technical challenges are yet to be overcome. Summarized here are the technical challenges associated with POC diagnostics from a RLS perspective and the latest advances in addressing these challenges are reviewed. PMID:26777725

  5. Ultrasonic Technology in Duress Alarms.

    ERIC Educational Resources Information Center

    Lee, Martha A.

    2000-01-01

    Provides the pros and cons of the most commonly used technologies in personal duress alarm systems in the school environment. Discussed are radio frequency devices, infrared systems, and ultrasonic technology. (GR)

  6. Automated Information System (AIS) Alarm System

    SciTech Connect

    Hunteman, W.

    1997-05-01

    The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.

  7. Alarming increase in refugees.

    PubMed

    1992-01-01

    Over the past decade and half there has been an alarming worldwide increase in refugees. The total rose form 2.8 million in 1976 to 8.2 million in 1980, to 17.3 million in 1990. Africa's refugees rose from 1.2 million in 1976 to 5.6 million in 1990. Asia's increase over this period was much more rapid--from a mere 180,000 to 8 million. In the Americas the numbers more than trebled, from 770,000 to 2.7 million. Europe was the smallest increase, from 570,000 to 894,000. International law defines a refugee as someone outside of their own country, who has a well-founded fear of persecution because of their political or religious beliefs or ethnic origin, and who cannot turn to their own country for protection. Most refugees are genuine by this definition. The increase reflects, in part, fallout from the cold war. Ethiopia, Mozambique and Angola accounted for almost 1/2 of Africa's refugees; Afghanistan alone for 3/4 of Asia's total. They fled, for the most part, from 1 poor country into another, where they added to shortages of land and fuelwood, and intensified environmental pressure. Malawi, 1 of the poorest countries in the world, is sheltering perhaps as many as 750,000 refugees from the war in Mozambique. But among these refugees--especially among those who turned to the rich countries for asylum--were an increasing number of people who were not suffering political persecution. Driven out of their homes by the collapse of their environment or economic despair, and ready to take any means to get across borders, they are a new category: economic and environmental refugees. The most spectacular attempts hit the television screens: the Vietnamese boat people, ships festooned with Albanians. Behind the headlines there was a growing tide of asylum seekers. The numbers rose 10-fold in Germany from 1983 to 1990. In Switzerland they multiplied by 4 times. In Europe, as a whole, they grew from 71,000 in 1983 to an estimated 550,000 in 1990. In 1990 the numbers threatened to

  8. A point-of-care PCR test for HIV-1 detection in resource-limited settings.

    PubMed

    Jangam, Sujit R; Agarwal, Abhishek K; Sur, Kunal; Kelso, David M

    2013-04-15

    A low-cost, fully integrated sample-to-answer, quantitative PCR (qPCR) system that can be used for detection of HIV-1 proviral DNA in infants at the point-of-care in resource-limited settings has been developed and tested. The system is based on a novel DNA extraction method, which uses a glass fiber membrane, a disposable assay card that includes on-board reagent storage, provisions for thermal cycling and fluorescence detection, and a battery-operated portable analyzer. The system is capable of automated PCR mix assembly using a novel reagent delivery system and performing qPCR. HIV-1 and internal control targets are detected using two spectrally separated fluorophores, FAM and Quasar 670. In this report, a proof-of-concept of the platform is demonstrated. Initial results with whole blood demonstrate that the test is capable of detecting HIV-1 in blood samples containing greater than 5000 copies of HIV-1. In resource-limited settings, a point-of-care HIV-1 qPCR test would greatly increase the number of test results that reach the infants caregivers, allowing them to pursue anti-retroviral therapy.

  9. Efficient measurement of point-to-set correlations and overlap fluctuations in glass-forming liquids

    NASA Astrophysics Data System (ADS)

    Berthier, Ludovic; Charbonneau, Patrick; Yaida, Sho

    2016-01-01

    Cavity point-to-set correlations are real-space tools to detect the roughening of the free-energy landscape that accompanies the dynamical slowdown of glass-forming liquids. Measuring these correlations in model glass formers remains, however, a major computational challenge. Here, we develop a general parallel-tempering method that provides orders-of-magnitude improvement for sampling and equilibrating configurations within cavities. We apply this improved scheme to the canonical Kob-Andersen binary Lennard-Jones model for temperatures down to the mode-coupling theory crossover. Most significant improvements are noted for small cavities, which have thus far been the most difficult to study. This methodological advance also enables us to study a broader range of physical observables associated with thermodynamic fluctuations. We measure the probability distribution of overlap fluctuations in cavities, which displays a non-trivial temperature evolution. The corresponding overlap susceptibility is found to provide a robust quantitative estimate of the point-to-set length scale requiring no fitting. By resolving spatial fluctuations of the overlap in the cavity, we also obtain quantitative information about the geometry of overlap fluctuations. We can thus examine in detail how the penetration length as well as its fluctuations evolve with temperature and cavity size.

  10. Efficient measurement of point-to-set correlations and overlap fluctuations in glass-forming liquids

    SciTech Connect

    Berthier, Ludovic; Charbonneau, Patrick; Yaida, Sho

    2016-01-14

    Cavity point-to-set correlations are real-space tools to detect the roughening of the free-energy landscape that accompanies the dynamical slowdown of glass-forming liquids. Measuring these correlations in model glass formers remains, however, a major computational challenge. Here, we develop a general parallel-tempering method that provides orders-of-magnitude improvement for sampling and equilibrating configurations within cavities. We apply this improved scheme to the canonical Kob-Andersen binary Lennard-Jones model for temperatures down to the mode-coupling theory crossover. Most significant improvements are noted for small cavities, which have thus far been the most difficult to study. This methodological advance also enables us to study a broader range of physical observables associated with thermodynamic fluctuations. We measure the probability distribution of overlap fluctuations in cavities, which displays a non-trivial temperature evolution. The corresponding overlap susceptibility is found to provide a robust quantitative estimate of the point-to-set length scale requiring no fitting. By resolving spatial fluctuations of the overlap in the cavity, we also obtain quantitative information about the geometry of overlap fluctuations. We can thus examine in detail how the penetration length as well as its fluctuations evolve with temperature and cavity size.

  11. A formula on the pressure for a set of generic points

    NASA Astrophysics Data System (ADS)

    Meson, A. M.; Vericat, F.

    2011-03-01

    Let (X, ƒ) be a dynamical system, with X a compact metric space and ƒ:X→X a continuous map. For any xɛX, let us consider the empirical measures En(x) = 1/n ∑ i=1n-1δfi(x)⊂M(X), where δ is the Dirac point mass measure. The limit set of the sequence {En(x)} will be denoted by V(x) A particularly interesting case is when V(x) = {μ}, i.e. the points for which the time-average along their orbits of any continuous potential ψ agrees with the average of ψ with respect to μ. This kind of points are called generic for the measure μ and let us denote Gμ = {x: V(x) = {μ}}. A measure μ is called a physical measure if there is a Lebesgue measure m such that m(Gμ)>0. In the case of considering C2 -maps ƒ :M→ M with a negative Lyapunov exponent, where M is a compact Riemannian manifold, the Sinai-Ruelle-Bowen measures (SRB-measures) are physical measures. In the context of Lattice Statistical Mechanics the scheme is the following: the phase space X is a subset of the space {x: x = (xi)iɛzd,xiɛω = {1,2, …,k}}, i.e.a space of configurations with spin ω and sites in the lattice L = Zd, the dynamics are given by the shift σ(x)i = xi+d, for any iɛZd and the measures (states) are En(x) = 1/Δn ∑ i = 0n-1δƒi(x), where Δn is the volume of the lattice [-n,n]d. The goal is to find an expression for PGμ (ψ), the topological pressure for the set Gμ of the potential ψ. Our analysis is more general, in the sense that we obtain a variational expression for sets GK = {x: V(x) = K}, with K a compact set of measures in X instead of working just in Gμ The condition imposed on the dynamical system is the so called almost property product, which is weaker than specification. Equilibrium case is when the dynamics have the properties of expansiveness and specification. This work generalizes previous results obtained for ψ≡0, i.e. for the topological entropy, (C.E. Pfister and W.G. Sullivan, Ergod. Th. and Dynam. Sys. 27, 929

  12. The contribution of viral genotype to plasma viral set-point in HIV infection.

    PubMed

    Hodcroft, Emma; Hadfield, Jarrod D; Fearnhill, Esther; Phillips, Andrew; Dunn, David; O'Shea, Siobhan; Pillay, Deenan; Leigh Brown, Andrew J

    2014-05-01

    Disease progression in HIV-infected individuals varies greatly, and while the environmental and host factors influencing this variation have been widely investigated, the viral contribution to variation in set-point viral load, a predictor of disease progression, is less clear. Previous studies, using transmission-pairs and analysis of phylogenetic signal in small numbers of individuals, have produced a wide range of viral genetic effect estimates. Here we present a novel application of a population-scale method based in quantitative genetics to estimate the viral genetic effect on set-point viral load in the UK subtype B HIV-1 epidemic, based on a very large data set. Analyzing the initial viral load and associated pol sequence, both taken before anti-retroviral therapy, of 8,483 patients, we estimate the proportion of variance in viral load explained by viral genetic effects to be 5.7% (CI 2.8-8.6%). We also estimated the change in viral load over time due to selection on the virus and environmental effects to be a decline of 0.05 log10 copies/mL/year, in contrast to recent studies which suggested a reported small increase in viral load over the last 20 years might be due to evolutionary changes in the virus. Our results suggest that in the UK epidemic, subtype B has a small but significant viral genetic effect on viral load. By allowing the analysis of large sample sizes, we expect our approach to be applicable to the estimation of the genetic contribution to traits in many organisms.

  13. The Set Point Theory of Well-Being Has Serious Flaws: On the Eve of a Scientific Revolution?

    ERIC Educational Resources Information Center

    Headey, Bruce

    2010-01-01

    Set-point theory is the main research paradigm in the field of subjective well-being (SWB). It has been extended and refined for 30 years to take in new results. The central plank of the theory is that adult set-points do not change, except temporarily in the face of major life events. There was always some "discordant data," including…

  14. Blood pressure long term regulation: A neural network model of the set point development

    PubMed Central

    2011-01-01

    Background The notion of the nucleus tractus solitarius (NTS) as a comparator evaluating the error signal between its rostral neural structures (RNS) and the cardiovascular receptor afferents into it has been recently presented. From this perspective, stress can cause hypertension via set point changes, so offering an answer to an old question. Even though the local blood flow to tissues is influenced by circulating vasoactive hormones and also by local factors, there is yet significant sympathetic control. It is well established that the state of maturation of sympathetic innervation of blood vessels at birth varies across animal species and it takes place mostly during the postnatal period. During ontogeny, chemoreceptors are functional; they discharge when the partial pressures of oxygen and carbon dioxide in the arterial blood are not normal. Methods The model is a simple biological plausible adaptative neural network to simulate the development of the sympathetic nervous control. It is hypothesized that during ontogeny, from the RNS afferents to the NTS, the optimal level of each sympathetic efferent discharge is learned through the chemoreceptors' feedback. Its mean discharge leads to normal oxygen and carbon dioxide levels in each tissue. Thus, the sympathetic efferent discharge sets at the optimal level if, despite maximal drift, the local blood flow is compensated for by autoregulation. Such optimal level produces minimum chemoreceptor output, which must be maintained by the nervous system. Since blood flow is controlled by arterial blood pressure, the long-term mean level is stabilized to regulate oxygen and carbon dioxide levels. After development, the cardiopulmonary reflexes play an important role in controlling efferent sympathetic nerve activity to the kidneys and modulating sodium and water excretion. Results Starting from fixed RNS afferents to the NTS and random synaptic weight values, the sympathetic efferents converged to the optimal values

  15. Neural set point for the control of arterial pressure: role of the nucleus tractus solitarius

    PubMed Central

    2010-01-01

    Background Physiological experiments have shown that the mean arterial blood pressure (MAP) can not be regulated after chemo and cardiopulmonary receptor denervation. Neuro-physiological information suggests that the nucleus tractus solitarius (NTS) is the only structure that receives information from its rostral neural nuclei and from the cardiovascular receptors and projects to nuclei that regulate the circulatory variables. Methods From a control theory perspective, to answer if the cardiovascular regulation has a set point, we should find out whether in the cardiovascular control there is something equivalent to a comparator evaluating the error signal (between the rostral projections to the NTS and the feedback inputs). The NTS would function as a comparator if: a) its lesion suppresses cardiovascular regulation; b) the negative feedback loop still responds normally to perturbations (such as mechanical or electrical) after cutting the rostral afferent fibers to the NTS; c) perturbation of rostral neural structures (RNS) to the NTS modifies the set point without changing the dynamics of the elicited response; and d) cardiovascular responses to perturbations on neural structures within the negative feedback loop compensate for much faster than perturbations on the NTS rostral structures. Results From the control theory framework, experimental evidence found currently in the literature plus experimental results from our group was put together showing that the above-mentioned conditions (to show that the NTS functions as a comparator) are satisfied. Conclusions Physiological experiments suggest that long-term blood pressure is regulated by the nervous system. The NTS functions as a comparator (evaluating the error signal) between its RNS and the cardiovascular receptor afferents and projects to nuclei that regulate the circulatory variables. The mean arterial pressure (MAP) is regulated by the feedback of chemo and cardiopulmonary receptors and the baroreflex

  16. Research on the fire alarming system of fiber grating

    NASA Astrophysics Data System (ADS)

    Qi, Yaobin

    2007-09-01

    The application of fiber grating sensing technology in fire alarming based on temperature detection has the advantages of high accuracy, high reliability and strong immunity from electronic and magnetic fields. It is especially advantageous to use this system in the petroleum and chemistry industry because it can provide an extraordinary safe means for the fire alarm. But due to the traditional optical Wavelength Division Multiplexing (WDM) technology is limited by the optic source bandwidth, the number of its multiplexing points is few. In this paper WDM technology will be developed mixing with Identified Bragg, which is called Identified and Wavelength Multiplexing, to build the Fiber Grating (FBG) fire alarm system integrated with computers. Some technologies applied in fire alarming system of fiber grating such as the transmission of test signals which pass through modulate and demodulate, the disposal of software system, the output of control signal and the strong ability of anti-disturbance have been studied and discussed.

  17. Students' Understanding of Limiting Behavior at a Point for Functions from [Set of Real Numbers][superscript 2] to [Set of Real Numbers

    ERIC Educational Resources Information Center

    Mamona-Downs, Joanna K.; Megalou, Foteini J.

    2013-01-01

    The aim of this paper is to examine students' understanding of the limiting behavior of a function from [set of real numbers][superscript 2] to [set of real numbers] at a point "P." This understanding depends on which definition is used for a limit. Several definitions are considered; two of these concern the notion of a neighborhood of "P", while…

  18. The ALARM Experiment

    ERIC Educational Resources Information Center

    Gerhardt, Ira

    2015-01-01

    An experiment was conducted over three recent semesters of an introductory calculus course to test whether it was possible to quantify the effect that difficulty with basic algebraic and arithmetic computation had on individual performance. Points lost during the term were classified as being due to either algebraic and arithmetic mistakes…

  19. Molecular mass dependence of point-to-set correlation length scale in polymers

    NASA Astrophysics Data System (ADS)

    Hanson, Ben; Pryamitsyn, Victor; Ganesan, Venkat

    2012-08-01

    We use a recently proposed metric, termed the point-to-set correlation functions, to probe the molecular weight dependence of the relevant static length scales in glass-forming oligomeric chain liquids of 4, 5, 8, and 10 repeat units. In agreement with the results for simple, monatomic fluids, we find that static length scales of the oligomers increase monotonically when the temperature is lowered towards the glass transition temperature of the fluid. More interestingly, the static length scale increases with increasing chain length. Within the bounds of error in our simulations, the static length scale appears to scale as the radius of gyration of the oligomer, but with a prefactor, which is much larger than unity and which grows with the temperature. The preceding behavior contrasts with the length scales extracted from the radial distribution function of the oligomer system, which is practically independent of the chain length.

  20. Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Paiva, Kleber; Mantelli, Marcia

    2011-01-01

    Loop heat pipes (LHPs) have been used for thermal control of several NASA and commercial orbiting spacecraft. The LHP operating temperature is governed by the saturation temperature of its compensation chamber (CC). Most LHPs use the CC temperature for feedback control of its operating temperature. There exists a thermal resistance between the heat source to be cooled by the LHP and the LHP's CC. Even if the CC set point temperature is controlled precisely, the heat source temperature will still vary with its heat output. For most applications, controlling the heat source temperature is of most interest. A logical question to ask is: "Can the heat source temperature be used for feedback control of the LHP operation?" A test program has been implemented to answer the above question. Objective is to investigate the LHP performance using the CC temperature and the heat source temperature for feedback control

  1. Actuation of elastomeric microvalves in point-of-care settings using handheld, battery-powered instrumentation.

    PubMed

    Addae-Mensah, Kweku A; Cheung, Yuk Kee; Fekete, Veronika; Rendely, Matthew S; Sia, Samuel K

    2010-06-21

    Although advanced fluid handling using elastomeric valves is useful for a variety of lab-on-a-chip procedures, their operation has traditionally relied on external laboratory infrastructure (such as gas tanks, computers, and ground electricity). This dependence has held back the use of elastomeric microvalves for point-of-care settings. Here, we demonstrate that microfabricated microvalves, via liquid-filled control channels, can be actuated using only a handheld instrument powered by a 9 V battery. This setup can achieve on-off fluid control with fast response times, coordinated switching of multiple valves, and operation of a biological assay. In the future, this technique may enable the widely used elastomeric microvalves (made by multilayer soft lithography) to be increasingly adopted for portable sensors and lab-on-a-chip systems.

  2. Salty solutions: their effects on thermal set points in behavioral repertoires of albino rats.

    PubMed

    Vitulli, W F; Aker, R; Howard, S W; Jones, W M; Kimball, M W; Quinn, J M

    1994-08-01

    Salt (sodium chloride) has been linked to increased blood pressure and a rise in core body temperature. The objective of this study was to investigate the role played by salt in altering behavioral thermoregulation in albino rats. Different doses of sodium chloride were administered (ip) prior to fixed-interval 2-min. schedules of microwave reinforcement in rats tested in a cold Skinner Box. Three Sprague-Dawley rats were conditioned to regulate their thermal environment with 5-sec. exposures of MW reinforcement in a repeated-measures reversal design. Friedman's non-parametric test showed significant differences among sodium chloride doses and physiologically normal saline. Post hoc sign tests showed that all doses of NaCl suppressed operant behavior for heat except 60 mg/kg. The hypothesis that sodium chloride lowers hypothalamic set point for heat was partially supported.

  3. Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Paiva, Kleber; Mantelli, Marcia

    2011-01-01

    The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

  4. Smart container UWB sensor system for situational awareness of intrusion alarms

    DOEpatents

    Romero, Carlos E.; Haugen, Peter C.; Zumstein, James M.; Leach, Jr., Richard R.; Vigars, Mark L.

    2013-06-11

    An in-container monitoring sensor system is based on an UWB radar intrusion detector positioned in a container and having a range gate set to the farthest wall of the container from the detector. Multipath reflections within the container make every point on or in the container appear to be at the range gate, allowing intrusion detection anywhere in the container. The system also includes other sensors to provide false alarm discrimination, and may include other sensors to monitor other parameters, e.g. radiation. The sensor system also includes a control subsystem for controlling system operation. Communications and information extraction capability may also be included. A method of detecting intrusion into a container uses UWB radar, and may also include false alarm discrimination. A secure container has an UWB based monitoring system

  5. Analysis of constant false alarm rate sidelobe canceller criterion

    NASA Astrophysics Data System (ADS)

    Reed, I. S.; Brennan, L. E.

    1985-05-01

    In this final report, the constant false alarm rate (CFAR) detection criterion for a sidelobe canceller (SLC) system, introduced in the last quarterly progress report, is found completely and analyzed. This new detection test for radar exhibits the desirable CFAR property that its probability of a false alarm (PFA) is functionally independent of the covariance of the actual noise field encountered. As a consequence, such a CFAR SLC system is ideally suited to cope with the newly evolving smart jammer threat to radar. An important objective, set in the last quarterly progress report, was to find both the false alarm and signal detection probabilities of this test. The first and most important of these two goals has been met. The probability of a false alarm (or PFA) of this CFAR SLC detection criterion is derived in closed form in this report. The success in finding the PFA is due primarily to the use of a generalization of Cochran's theorem.

  6. The Relationship between Population T4/TSH Set Point Data and T4/TSH Physiology.

    PubMed

    Fitzgerald, Stephen Paul; Bean, Nigel Geoffrey

    2016-01-01

    Context. Population studies of the distribution of T4/TSH set points suggest a more complex inverse relationship between T4 and TSH than that suggested by physiological studies. The reasons for the similarities and differences between the curves describing these relationships are unresolved. Methods. We subjected the curve, derived from empiric data, describing the TSH suppression response to T4, and the more mathematically derived curve describing the T4 response to TSH, to the different possible models of population variation. The implied consequences of these in terms of generating a population distribution of T4/TSH equilibrium points (a "population curve") were generated and compared to the empiric population curve. The physiological responses to primary hypothyroidism and hyperthyroidism were incorporated into the analysis. Conclusions. Though the population curve shows a similarly inverse relationship, it is describing a different relationship than the curve describing the suppression of TSH by T4. The population curve is consistent with the physiological studies of the TSH response to T4 and implies a greater interindividual variation in the positive thyroid T4 response to TSH than in the central inhibitory TSH response to T4. The population curve in the dysthyroid states is consistent with known physiological responses to these states.

  7. Feasibility of HIV point-of-care tests for resource-limited settings: challenges and solutions.

    PubMed

    Stevens, Wendy; Gous, Natasha; Ford, Nathan; Scott, Lesley E

    2014-09-08

    Improved access to anti-retroviral therapy increases the need for affordable monitoring using assays such as CD4 and/or viral load in resource-limited settings. Barriers to accessing treatment, high rates of loss to initiation and poor retention in care are prompting the need to find alternatives to conventional centralized laboratory testing in certain countries. Strong advocacy has led to a rapidly expanding repertoire of point-of-care tests for HIV. point-of-care testing is not without its challenges: poor regulatory control, lack of guidelines, absence of quality monitoring and lack of industry standards for connectivity, to name a few. The management of HIV increasingly requires a multidisciplinary testing approach involving hematology, chemistry, and tests associated with the management of non-communicable diseases, thus added expertise is needed. This is further complicated by additional human resource requirements and the need for continuous training, a sustainable supply chain, and reimbursement strategies. It is clear that to ensure appropriate national implementation either in a tiered laboratory model or a total decentralized model, clear country-specific assessments need to be conducted.

  8. A new method for defining and managing process alarms and for correcting process operation when an alarm occurs.

    PubMed

    Brooks, Robin; Thorpe, Richard; Wilson, John

    2004-11-11

    A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice.

  9. An updated global grid point surface air temperature anomaly data set: 1851--1990

    SciTech Connect

    Sepanski, R.J.; Boden, T.A.; Daniels, R.C.

    1991-10-01

    This document presents land-based monthly surface air temperature anomalies (departures from a 1951--1970 reference period mean) on a 5{degree} latitude by 10{degree} longitude global grid. Monthly surface air temperature anomalies (departures from a 1957--1975 reference period mean) for the Antarctic (grid points from 65{degree}S to 85{degree}S) are presented in a similar way as a separate data set. The data were derived primarily from the World Weather Records and the archives of the United Kingdom Meteorological Office. This long-term record of temperature anomalies may be used in studies addressing possible greenhouse-gas-induced climate changes. To date, the data have been employed in generating regional, hemispheric, and global time series for determining whether recent (i.e., post-1900) warming trends have taken place. This document also presents the monthly mean temperature records for the individual stations that were used to generate the set of gridded anomalies. The periods of record vary by station. Northern Hemisphere station data have been corrected for inhomogeneities, while Southern Hemisphere data are presented in uncorrected form. 14 refs., 11 figs., 10 tabs.

  10. Detection of autoantibodies in a point-of-care rheumatology setting.

    PubMed

    Konstantinov, Konstantin N; Tzamaloukas, Antonios; Rubin, Robert L

    2013-08-01

    Autoimmune rheumatic diseases are common and confront society with serious medical, social, and financial burdens imposed by their debilitating nature. Many autoimmune diseases are associated with a particular set of autoantibodies, which have emerged as highly useful to define and classify disease, predict flares, or monitor efficacy of therapy. However, current practice for monitoring autoantibodies is protracted, labor-intensive, and expensive. This review provides an overview on the value of point-of-care (POC) biosensor technology in the diagnosis and management of patients with autoimmune rheumatic diseases. Real-time measurement of autoantibodies will clearly benefit the rheumatology practice in emergency and urgent care settings, where definitive diagnosis is essential for initiation of correct critical care therapy. Immediate serological information in clinic will provide considerable value for long-term patient care and an opportunity for an instant, result-deduced therapeutic action, avoiding delays and improving compliance, especially in field-based and remote areas. We describe the particular autoantibodies that are useful disease and activity markers and would, therefore, be attractive to POC applications. Already existing biosensors and platforms that show promise for autoantibody testing are summarized and comparatively evaluated. As POC assessment is gaining momentum in several areas of patient care, we propose that rheumatology is poised to benefit from this innovative and affordable technology.

  11. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    PubMed Central

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  12. Nurses' experiences with bed exit alarms may lead to ambivalence about their effectiveness.

    PubMed

    Hubbartt, Beth; Davis, Sarah G; Kautz, Donald D

    2011-01-01

    The literature reports conflicting evidence regarding the effectiveness of any single intervention, including bed exit alarms, in preventing falls. Yet bed exit alarms are widely used in healthcare settings as part of comprehensive fall-prevention programs even though no large-scale randomized controlled trials have demonstrated their effectiveness. As a part of a quality improvement project, bed alarms were piloted on two nursing units in a Level I trauma center. Nurses' patterns of use, their experiences and beliefs about bed alarms, and the literature regarding bed exit alarms were explored. Alarms were used with confused and agitated patients who did not fall. Nurses said that bed alarms may have helped prevent falls, but, even with bed alarms in use, nurses still needed to monitor their patients hourly. The conflicting experiences of nurses using the alarms, combined with nurses' comments and literature both supporting and not supporting bed alarms, shed light on the dilemma nurses face when prioritizing safe patient care and the ambivalence some nurses experience regarding bed alarms.

  13. The Best Ever Alarm System Toolkit

    SciTech Connect

    Kasemir, Kay; Chen, Xihui; Danilova, Katia

    2009-01-01

    Learning from our experience with the standard Experimental Physics and Industrial Control System (EPICS) alarm handler (ALH) as well as a similar intermediate approach based on script-generated operator screens, we developed the Best Ever Alarm System Toolkit (BEAST). It is based on Java and Eclipse on the Control System Studio (CSS) platform, using a relational database (RDB) to store the configuration and log actions. It employs a Java Message Service (JMS) for communication between the modular pieces of the toolkit, which include an Alarm Server to maintain the current alarm state, an arbitrary number of Alarm Client user interfaces (GUI), and tools to annunciate alarms or log alarm related actions. Web reports allow us to monitor the alarm system performance and spot deficiencies in the alarm configuration. The Alarm Client GUI not only gives the end users various ways to view alarms in tree and table, but also makes it easy to access the guidance information, the related operator displays and other CSS tools. It also allows online configuration to be simply modified from the GUI. Coupled with a good "alarm philosophy" on how to provide useful alarms, we can finally improve the configuration to achieve an effective alarm system.

  14. Sun-glint false alarm mitigation in a maritime scenario

    NASA Astrophysics Data System (ADS)

    Rossi, Alessandro; Riccobono, Aldo; Landini, Stefano

    2014-10-01

    Airborne hyperspectral imaging can be exploited to detect anomalous objects in the maritime scenario. Due to the objects high contrast with respect to the sea surface, detection can be easily accomplished by means of local anomaly detectors, such as the well-known Reed-Xiaoli (RX) algorithm. During the development of a real-time system for the detection of anomalous pixels, it has been noticed that the performance of detection is deeply affected by the presence of sun-glint. The reflection on the sea surface of the solar radiation produces a high density of alarms, that makes challenging the task of detecting the objects of interest. In this paper, it is introduced a strategy aimed at discriminating the sun-glint false alarms from the effective alarms related to targets of potential interest. False alarms due to glint are mitigated performing a local spatio-spectral analysis on each alarm furnished by the anomaly detector. The technique has been tested on hyperspectral images collected during a measurement campaign carried out near Pisa, Italy. The Selex ES SIMGA hyperspectral sensor was mounted on board of an airplane to collect high spectral resolution images in both the VNIR and SWIR spectral channels. Several experiments were carried out, setting up scenarios with small man-made objects deployed on the sea surface, so as to simulate search and rescue operations. The results have highlighted the effectiveness of the proposed solution in terms of mitigation of false alarms due to sun-glints on the maritime scenario.

  15. Genetic analysis of the gravitropic set-point angle in lateral roots of arabidopsis

    NASA Astrophysics Data System (ADS)

    Mullen, J. L.; Hangarter, R. P.

    2003-05-01

    Research on gravity responses in plants has mostly focused on primary roots and shoots, which typically orient to a vertical orientation. However, the distribution of lateral organs and their characteristically non-vertical growth orientation are critical for the determination of plant form. For example, in Arabidopsis, when lateral roots emerge from the primary root, they grow at a nearly horizontal orientation. As they elongate, the roots slowly curve until they eventually reach a vertical orientation. The regulation of this lateral root orientation is an important component affecting overall root system architecture. We found that this change in orientation is not simply due to the onset of gravitropic competence, as non-vertical lateral roots are capable of both positive and negative gravitropism. Thus, the horizontal growth of new lateral roots appears to be determined by what is called the gravitropic set-point angle (GSA). This developmental control of the GSA of lateral roots in Arabidopsis provides a useful system for investigating the components involved in regulating gravitropic responses. Using this system, we have identified several Arabidopsis mutants that have altered lateral root orientations but maintain normal primary root orientation.

  16. Criticality as a Set-Point for Adaptive Behavior in Neuromorphic Hardware

    PubMed Central

    Srinivasa, Narayan; Stepp, Nigel D.; Cruz-Albrecht, Jose

    2015-01-01

    Neuromorphic hardware are designed by drawing inspiration from biology to overcome limitations of current computer architectures while forging the development of a new class of autonomous systems that can exhibit adaptive behaviors. Several designs in the recent past are capable of emulating large scale networks but avoid complexity in network dynamics by minimizing the number of dynamic variables that are supported and tunable in hardware. We believe that this is due to the lack of a clear understanding of how to design self-tuning complex systems. It has been widely demonstrated that criticality appears to be the default state of the brain and manifests in the form of spontaneous scale-invariant cascades of neural activity. Experiment, theory and recent models have shown that neuronal networks at criticality demonstrate optimal information transfer, learning and information processing capabilities that affect behavior. In this perspective article, we argue that understanding how large scale neuromorphic electronics can be designed to enable emergent adaptive behavior will require an understanding of how networks emulated by such hardware can self-tune local parameters to maintain criticality as a set-point. We believe that such capability will enable the design of truly scalable intelligent systems using neuromorphic hardware that embrace complexity in network dynamics rather than avoiding it. PMID:26648839

  17. A Smartphone-Based Genotyping Method for Hepatitis B Virus at Point-of-Care Settings.

    PubMed

    Jiang, Huiqin; Wu, Di; Song, Liuwei; Yuan, Quan; Ge, Shengxiang; Min, Xiaoping; Xia, Ningshao; Qian, Shizhi; Qiu, Xianbo

    2017-04-01

    We reported a rapid, convenient, and easy-to-use genotyping method for hepatitis B virus (HBV) based on the smartphone at point-of-care (POC) settings. To perform HBV genotyping especially for genotypes A, B, C, and D, a smartphone is used to image and analyze a one-step immunoassay lateral flow strip functionalized with genotype-specific monoclonal antibodies (mAbs) on multiple capture lines. A light-emitting diode (LED) positioned on the top of the lateral flow strip is used to shine the multiple capture lines for excitation. Fluorescence detection is obtained with a smartphone whose camera is used to take the fluorescent images. An intelligent algorithm is developed to first identify each capture line from the fluorescent image and then determine the HBV genotype based on a genotyping model. Based on the pattern of the detection signal from different samples, a custom HBV genotyping model is developed. Custom application software running on a smartphone is developed with Java to collect and analyze the fluorescent image, display the genotyping result, and transmit it if necessary. Compared with the existing methods with nucleic acid analysis, more convenient, instant, and efficient HBV genotyping with significantly lower cost and a simpler procedure can be obtained with the developed smartphone POC HBV genotyping method.

  18. Genetic analysis of the gravitropic set-point angle in lateral roots of Arabidopsis

    NASA Technical Reports Server (NTRS)

    Mullen, J. L.; Hangarter, R. P.; Kiss, J. Z. (Principal Investigator)

    2003-01-01

    Research on gravity responses in plants has mostly focused on primary roots and shoots, which typically orient to a vertical orientation. However, the distribution of lateral organs and their characteristically non-vertical growth orientation are critical for the determination of plant form. For example, in Arabidopsis, when lateral roots emerge from the primary root, they grow at a nearly horizontal orientation. As they elongate, the roots slowly curve until they eventually reach a vertical orientation. The regulation of this lateral root orientation is an important component affecting overall root system architecture. We found that this change in orientation is not simply due to the onset of gravitropic competence, as non-vertical lateral roots are capable of both positive and negative gravitropism. Thus, the horizontal growth of new lateral roots appears to be determined by what is called the gravitropic set-point angle (GSA). This developmental control of the GSA of lateral roots in Arabidopsis provides a useful system for investigating the components involved in regulating gravitropic responses. Using this system, we have identified several Arabidopsis mutants that have altered lateral root orientations but maintain normal primary root orientation. c2003 COSPAR. Published by Elsevier Ltd. All rights reserved.

  19. Onsite Portable Alarm System - Its Merit and Application

    NASA Astrophysics Data System (ADS)

    Saita, J.; Sato, T.; Nakamura, Y.

    2007-12-01

    Recently an existence of the earthquake early warning system (EEWS) becomes popular. In general, the EEWS will be installed in a fixed observation site and it may consist of several separated components such as a sensing portion, A/D converter, an information processing potion and so on. The processed information for warning may be transmitted to network via fixed communication line, and therefore this kind of alarm system is called as Network Alarm System. On the other hand, after the severe earthquake damage, it is very important to save the disaster victims immediately. These rescue staffs are also under the risk of aftershocks and need a local alarm not depending on the network, so this kind of alarm can be called as Onsite Alarm. But the common early warning system is too complex to set onsite temporary, and even if possible to install, the alarm is too late to receive at the epicentral area. However, the new generation earthquake early warning system FREQL can issue the P wave alarm by minimum 0.2 seconds after P wave detection. And FREQL is characterized as the unique all-in-one seismometer with power unit. At the time of the 2004 Niigata-Ken-Chuetsu earthquake, a land slide attacked a car just passing. A hyper rescue team of Tokyo Fire Department pulled the survivor, one baby, from the land slide area. During their activity the rescue team was exposed to the risk of secondary hazards caused by the aftershocks. It was clear that it is necessary to use a portable warning system to issue the onsite P wave alarm. Because FREQL was originally developed as portable equipment, Tokyo Fire Department asked us to modify it to the portable equipment with the loud sound and the light signal. In this moment, this portable FREQL has equipped in nation wide. When the hyper rescue team of Tokyo Fire Department was sent to Pakistan as a task force for rescue work of the 2005 Pakistan earthquake, the portable FREQL was used as important onsite portable warning system and P

  20. Pointing Sets the Stage for Learning Language--and Creating Language

    ERIC Educational Resources Information Center

    Goldin-Meadow, Susan

    2007-01-01

    Tomasello, Carpenter, and Liszkowski (2007) have argued that pointing gestures do much more than single out objects in the world. Pointing gestures function as part of a system of shared intentionality even at early stages of development. As such, pointing gestures form the platform on which linguistic communication rests, paving the way for later…

  1. Genetics of the gravitropic set-point angle in lateral organs of Arabidopsis

    NASA Astrophysics Data System (ADS)

    Mullen, J.; Hangarter, R.

    Research on gravity responses in plants has mostly focused on primary roots and shoots, which typically orient to a vertical orientation. However, the distribution of lateral organs and their typically non-vertical growth orientation are critical for the determination of plant form. For example, in Arabidopsis, when lateral roots emerge from the primary root, they grow at a nearly horizontal orientation. As they elongate, the roots slowly curve until they eventually reach a vertical orientation. The regulation of this lateral root orientation is an important component affecting the overall root system architecture. We found that this change in orientation is not simply due to the onset of gravitropic competence, as non-vertical lateral roots are capable of both positive and negative gravitropism. Thus, the horizontal growth the new lateral roots is determined by what is called the gravitropic set-point angle (GSA). This developmental control of the GSA of lateral roots in Arabidopsis provides a useful system for investigating the components involved in regulating gravitropic responses. Using this system, we have identified several Arabidopsis mutants that have altered lateral root orientations but maintain normal primary root orientation. Two of these mutants also have altered orientation of their rosette leaves, indicating some common mechanisms in the positioning of root and shoot lateral organs. Rosette leaves and lateral roots also have in common a regulation of orientation by red light that may be due to red-light-dependent changes in the GSA. Further molecular and physiological analyses of the GSA mutants will provide insight into the basis of GSA regulation and, thus, a better understanding of how gravity controls plant architecture. [This work was supported by the National Aeronautics and Space Administration through grant no. NCC 2-1200.

  2. An application of a dynamical set point policy to main irrigation canals using in-line storage

    NASA Astrophysics Data System (ADS)

    Hashemy Shahdany, S. M.; Maestre, J. M.; Van Overloop, P. J.; Monem, M. J.

    2012-04-01

    In this study a set of different set points are taken into account for several pools of the Dez irrigation canal. The set points are calculated according to the water demands that are expected during the next hours. The rationale behind considering a group of set points is that it can be interesting to store water into different pools, as in-line reservoirs, in order to reduce the delay time and to compensate possible mismatches between upstream supply and downstream demand. A severe and sudden increasing - decreasing flow schedule has been applied by using Sobek hydrodynamic model for normal operation and operation with using in-line storage. A controller is used to choose between these set points in order to obtain the highest possible control performance. To this end, we consider a model predictive controller that follows each of the set points. As a consequence, different control vectors are calculated and only the one that minimizes the expected cost is implemented. This policy is repeated in a receding horizon fashion each time step. Finally, in order to test the proposed technique, we have carried out different simulations that compare it with other popular techniques such as local feedback PI and standard MPC. The proposed method enables main irrigation canals continue to flow at night in large and medium size main canals.

  3. Priority coding for control room alarms

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    Indicating the priority of a spatially fixed, activated alarm tile on an alarm tile array by a shape coding at the tile, and preferably using the same shape coding wherever the same alarm condition is indicated elsewhere in the control room. The status of an alarm tile can change automatically or by operator acknowledgement, but tones and/or flashing cues continue to provide status information to the operator.

  4. Make an Alarm! Grades 3-5.

    ERIC Educational Resources Information Center

    Rushton, Erik; Ryan, Emily; Swift, Charles

    After reading the story "Dear Mr. Henshaw" by Beverly Cleary, students build an alarm system for something in the classroom as the main character, Leigh, does to protect his lunchbox from thieves. Students learn about alarms and use their creativity to create an alarm system to protect their lockers, desk, or classroom door. This activity uses a…

  5. 21 CFR 876.2040 - Enuresis alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Enuresis alarm. 876.2040 Section 876.2040 Food and... GASTROENTEROLOGY-UROLOGY DEVICES Monitoring Devices § 876.2040 Enuresis alarm. (a) Identification. An enuresis... type of device includes conditioned response enuresis alarms. (b) Classification. Class II...

  6. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  7. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  8. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  9. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  10. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  11. 46 CFR 129.530 - General alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm. 129.530 Section 129.530 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Miscellaneous Electrical Systems § 129.530 General alarm. Each vessel must be fitted with a general alarm...

  12. 46 CFR 129.530 - General alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm. 129.530 Section 129.530 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Miscellaneous Electrical Systems § 129.530 General alarm. Each vessel must be fitted with a general alarm...

  13. Non-rigid point set registration of curves: registration of the superficial vessel centerlines of the brain

    NASA Astrophysics Data System (ADS)

    Marreiros, Filipe M. M.; Wang, Chunliang; Rossitti, Sandro; Smedby, Örjan

    2016-03-01

    In this study we present a non-rigid point set registration for 3D curves (composed by 3D set of points). The method was evaluated in the task of registration of 3D superficial vessels of the brain where it was used to match vessel centerline points. It consists of a combination of the Coherent Point Drift (CPD) and the Thin-Plate Spline (TPS) semilandmarks. The CPD is used to perform the initial matching of centerline 3D points, while the semilandmark method iteratively relaxes/slides the points. For the evaluation, a Magnetic Resonance Angiography (MRA) dataset was used. Deformations were applied to the extracted vessels centerlines to simulate brain bulging and sinking, using a TPS deformation where a few control points were manipulated to obtain the desired transformation (T1). Once the correspondences are known, the corresponding points are used to define a new TPS deformation(T2). The errors are measured in the deformed space, by transforming the original points using T1 and T2 and measuring the distance between them. To simulate cases where the deformed vessel data is incomplete, parts of the reference vessels were cut and then deformed. Furthermore, anisotropic normally distributed noise was added. The results show that the error estimates (root mean square error and mean error) are below 1 mm, even in the presence of noise and incomplete data.

  14. The homeostatic set point of the hypothalamus-pituitary-thyroid axis – maximum curvature theory for personalized euthyroid targets

    PubMed Central

    2014-01-01

    Background Despite rendering serum free thyroxine (FT4) and thyrotropin (TSH) within the normal population ranges broadly defined as euthyroidism, many patients being treated for hyperthyroidism and hypothyroidism persistently experience subnormal well-being discordant from their pre-disease healthy euthyroid state. This suggests that intra-individual physiological optimal ranges are narrower than laboratory-quoted normal ranges and implies the existence of a homeostatic set point encoded in the hypothalamic-pituitary-thyroid (HPT) axis that is unique to every individual. Methods We have previously shown that the dose–response characteristic of the hypothalamic-pituitary (HP) unit to circulating thyroid hormone levels follows a negative exponential curve. This led to the discovery that the normal reference intervals of TSH and FT4 fall within the ‘knee’ region of this curve where the maximum curvature of the exponential HP characteristic occurs. Based on this observation, we develop the theoretical framework localizing the position of euthyroid homeostasis over the point of maximum curvature of the HP characteristic. Results The euthyroid set points of patients with primary hypothyroidism and hyperthyroidism can be readily derived from their calculated HP curve parameters using the parsimonious mathematical model above. It can be shown that every individual has a euthyroid set point that is unique and often different from other individuals. Conclusions In this treatise, we provide evidence supporting a set point-based approach in tailoring euthyroid targets. Rendering FT4 and TSH within the laboratory normal ranges can be clinically suboptimal if these hormone levels are distant from the individualized euthyroid homeostatic set point. This mathematical technique permits the euthyroid set point to be realistically computed using an algorithm readily implementable for computer-aided calculations to facilitate precise targeted dosing of patients in this modern

  15. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  16. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  17. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  18. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  19. Sets meeting isometric copies of the lattice Z2 in exactly one point

    PubMed Central

    Jackson, Steve; Mauldin, R. Daniel

    2002-01-01

    The construction of a subset S of ℝ2 such that each isometric copy of ℤ2 (the lattice points in the plane) meets S in exactly one point is indicated. This provides a positive answer to a problem of H. Steinhaus [Sierpiński, W. (1958) Fund. Math. 46, 191–194]. PMID:12466499

  20. Eye-Tracking Students' Attention to PowerPoint Photographs in a Science Education Setting

    ERIC Educational Resources Information Center

    Slykhuis, David A.; Wiebe, Eric N.; Annetta, Len A.

    2005-01-01

    Eye-tracking technology allows for the determination of the exact location of the point of gaze of a subject's eye. This study sought to take advantage of this ability to determine how students attend to science related photographs. Pre-service science teachers were shown a PowerPoint[TM] Presentation with embedded photographs. The photographs…

  1. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  2. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  3. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  4. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  5. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  6. SUBSURFACE VISUAL ALARM SYSTEM ANALYSIS

    SciTech Connect

    D.W. Markman

    2001-08-06

    The ''Subsurface Fire Hazard Analysis'' (CRWMS M&O 1998, page 61), and the document, ''Title III Evaluation Report for the Surface and Subsurface Communication System'', (CRWMS M&O 1999a, pages 21 and 23), both indicate the installed communication system is adequate to support Exploratory Studies Facility (ESF) activities with the exception of the mine phone system for emergency notification purposes. They recommend the installation of a visual alarm system to supplement the page/party phone system The purpose of this analysis is to identify data communication highway design approaches, and provide justification for the selected or recommended alternatives for the data communication of the subsurface visual alarm system. This analysis is being prepared to document a basis for the design selection of the data communication method. This analysis will briefly describe existing data or voice communication or monitoring systems within the ESF, and look at how these may be revised or adapted to support the needed data highway of the subsurface visual alarm. system. The existing PLC communication system installed in subsurface is providing data communication for alcove No.5 ventilation fans, south portal ventilation fans, bulkhead doors and generator monitoring system. It is given that the data communication of the subsurface visual alarm system will be a digital based system. It is also given that it is most feasible to take advantage of existing systems and equipment and not consider an entirely new data communication system design and installation. The scope and primary objectives of this analysis are to: (1) Briefly review and describe existing available data communication highways or systems within the ESF. (2) Examine technical characteristics of an existing system to disqualify a design alternative is paramount in minimizing the number of and depth of a system review. (3) Apply general engineering design practices or criteria such as relative cost, and degree of

  7. HYBRID ALARM SYSTEMS: COMBINING SPATIAL ALARMS AND ALARM LISTS FOR OPTIMIZED CONTROL ROOM OPERATION

    SciTech Connect

    Ronald L. Boring; J.J. Persensky

    2012-07-01

    The US Department of Energy (DOE) is sponsoring research, development, and deployment on Light Water Reactor Sustainability (LWRS), in which the Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe operational life extension of current nuclear power plants. One of the main areas of focus is control room modernization. Within control room modernization, alarm system upgrades present opportunities to meet the broader goals of the LWRS project in demonstrating the use and safety of the advanced instrumentation and control (I&C) technologies and the short-term and longer term objectives of the plant. In this paper, we review approaches for and human factors issues behind upgrading alarms in the main control room of nuclear power plants.

  8. Multiple Time Courses of Vestibular Set-Point Adaptation Revealed by Sustained Magnetic Field Stimulation of the Labyrinth.

    PubMed

    Jareonsettasin, Prem; Otero-Millan, Jorge; Ward, Bryan K; Roberts, Dale C; Schubert, Michael C; Zee, David S

    2016-05-23

    A major focus in neurobiology is how the brain adapts its motor behavior to changes in its internal and external environments [1, 2]. Much is known about adaptively optimizing the amplitude and direction of eye and limb movements, for example, but little is known about another essential form of learning, "set-point" adaptation. Set-point adaptation balances tonic activity so that reciprocally acting, agonist and antagonist muscles have a stable platform from which to launch accurate movements. Here, we use the vestibulo-ocular reflex-a simple behavior that stabilizes the position of the eye while the head is moving-to investigate how tonic activity is adapted toward a new set point to prevent eye drift when the head is still [3, 4]. Set-point adaptation was elicited with magneto-hydrodynamic vestibular stimulation (MVS) by placing normal humans in a 7T MRI for 90 min. MVS is ideal for prolonged labyrinthine activation because it mimics constant head acceleration and induces a sustained nystagmus similar to natural vestibular lesions [5, 6]. The MVS-induced nystagmus diminished slowly but incompletely over multiple timescales. We propose a new adaptation hypothesis, using a cascade of imperfect mathematical integrators, that reproduces the response to MVS (and more natural chair rotations), including the gradual decrease in nystagmus as the set point changes over progressively longer time courses. MVS set-point adaptation is a biological model with applications to basic neurophysiological research into all types of movements [7], functional brain imaging [8], and treatment of vestibular and higher-level attentional disorders by introducing new biases to counteract pathological ones [9].

  9. False alarm rates of three third-generation pulse oximeters in PACU, ICU and IABP patients.

    PubMed

    Lutter, Norbert O; Urankar, Sabine; Kroeber, Steffi

    2002-01-01

    The objective of this clinical study was to determine alarm rates--in particular the frequency of false positive alarms--of three third-generation pulse oximeters in the postanesthesia care unit (PACU), the intensive care unit (ICU), and in patients with an intra-aortic balloon pump (IABP): Nellcor Symphony N-3000, a Masimo IVY 2000, and Agilent Viridia CMS 2000. All alarms were classified into technical/physiological and false/correct. 235 consecutive ASA physical status I-IV patients after surgery were included into the study. In the PACU false positive alarms were rare: CMS n = 60, N-3000 n = 60, Masimo n = 87. Bland-Altman testing discovered only negligible differences of alarm rates and dropout times. Out of a total of 728 alarms 67.3% were classified as false positive in ICU-patients: 97 alarms by CMS, 176 by N-3000 and 218 by Masimo SET. If IABP was present, CMS indicated a significant smaller number of false positive alarms (n = 35, 7.2%) when compared to Masimo SET (n = 188, 38.9%) and N-3000 (n = 229, 47.4%), consecutively the majority of false positive alarms (76.2%) can be rated as a result of the interference of IABP. Unless IABP (and to a considerably smaller extent cardiac arrhythmia) is present the pulse oximeters do not differ significantly regarding sensitivity and specificity.

  10. Testing Set-Point Theory in a Swiss National Sample: Reaction and Adaptation to Major Life Events

    PubMed Central

    Anusic, Ivana; Yap, Stevie C. Y.; Lucas, Richard E.

    2014-01-01

    Set-point theory posits that individuals react to the experience of major life events, but quickly adapt back to pre-event baseline levels of subjective well-being in the years following the event. A large, nationally representative panel study of Swiss households was used to examine set-point theory by investigating the extent of adaptation following the experience of marriage, childbirth, widowhood, unemployment, and disability. Our results demonstrate that major life events are associated with marked change in life satisfaction and, for some events (e.g., marriage, disability), these changes are relatively long lasting even when accounting for normative, age related change. PMID:25419036

  11. Set points, settling points and some alternative models: theoretical options to understand how genes and environments combine to regulate body adiposity

    PubMed Central

    Speakman, John R.; Levitsky, David A.; Allison, David B.; Bray, Molly S.; de Castro, John M.; Clegg, Deborah J.; Clapham, John C.; Dulloo, Abdul G.; Gruer, Laurence; Haw, Sally; Hebebrand, Johannes; Hetherington, Marion M.; Higgs, Susanne; Jebb, Susan A.; Loos, Ruth J. F.; Luckman, Simon; Luke, Amy; Mohammed-Ali, Vidya; O’Rahilly, Stephen; Pereira, Mark; Perusse, Louis; Robinson, Tom N.; Rolls, Barbara; Symonds, Michael E.; Westerterp-Plantenga, Margriet S.

    2011-01-01

    The close correspondence between energy intake and expenditure over prolonged time periods, coupled with an apparent protection of the level of body adiposity in the face of perturbations of energy balance, has led to the idea that body fatness is regulated via mechanisms that control intake and energy expenditure. Two models have dominated the discussion of how this regulation might take place. The set point model is rooted in physiology, genetics and molecular biology, and suggests that there is an active feedback mechanism linking adipose tissue (stored energy) to intake and expenditure via a set point, presumably encoded in the brain. This model is consistent with many of the biological aspects of energy balance, but struggles to explain the many significant environmental and social influences on obesity, food intake and physical activity. More importantly, the set point model does not effectively explain the ‘obesity epidemic’ – the large increase in body weight and adiposity of a large proportion of individuals in many countries since the 1980s. An alternative model, called the settling point model, is based on the idea that there is passive feedback between the size of the body stores and aspects of expenditure. This model accommodates many of the social and environmental characteristics of energy balance, but struggles to explain some of the biological and genetic aspects. The shortcomings of these two models reflect their failure to address the gene-by-environment interactions that dominate the regulation of body weight. We discuss two additional models – the general intake model and the dual intervention point model – that address this issue and might offer better ways to understand how body fatness is controlled. PMID:22065844

  12. Process is the point: justice and human rights: priority setting and fair deliberative process.

    PubMed

    Gruskin, Sofia; Daniels, Norman

    2008-09-01

    Most people responsible for setting priorities in health have considerable expertise relevant to deciding how to use resources effectively and the kinds of improvements that should be emphasized. Most are also concerned with distributing improvements equitably. Accordingly, they often invoke human rights or principles of distributive justice to legitimize choices that create winners and losers. We propose an approach that draws on the strengths of both perspectives as a way to add legitimacy to efforts to set priorities in health. Our proposal provides a process for setting priorities but is not a formula or an algorithm for generating particular priorities. We propose an approach that would do away with the process through which priorities are set and decisions made, and suggest the value of a focus on the process of legitimizing these decisions.

  13. HOME INSECURITY: NO ALARMS, FALSE ALARMS, AND SIGINT

    SciTech Connect

    Lamb, Logan M

    2014-01-01

    The market share of home security systems has substantially increased as vendors incorporate more desirable features: intrusion detection, automation, wireless, and LCD touch panel controls. Wireless connectivity allows vendors to manufacture cheaper, more featureful products that require little to no home modification to install. Consumer win, since adding devices is easier. The result: an ostensibly more secure, convenient, and connected home for a larger number of citizens. Sadly, this hypothesis is flawed; the idea of covering a home with more security sensors does not translate into a more secure home. Additionally, the number of homes using these vulnerable systems is large, and the growth rate is increasing producing a even larger problem. In this talk, I will demonstrate a generalized approach for compromising three systems: ADT, the largest home security dealer in North America; Honeywell, one of the largest manufacturers of security devices; and Vivint, a top 5 security dealer. We will suppress alarms, create false alarms, and collect artifacts that facilitate tracking the movements of individuals in their homes.

  14. Estimation of melting points of large set of persistent organic pollutants utilizing QSPR approach.

    PubMed

    Watkins, Marquita; Sizochenko, Natalia; Rasulev, Bakhtiyor; Leszczynski, Jerzy

    2016-03-01

    The presence of polyhalogenated persistent organic pollutants (POPs), such as Cl/Br-substituted benzenes, biphenyls, diphenyl ethers, and naphthalenes has been identified in all environmental compartments. The exposure to these compounds can pose potential risk not only for ecological systems, but also for human health. Therefore, efficient tools for comprehensive environmental risk assessment for POPs are required. Among the factors vital for environmental transport and fate processes is melting point of a compound. In this study, we estimated the melting points of a large group (1419 compounds) of chloro- and bromo- derivatives of dibenzo-p-dioxins, dibenzofurans, biphenyls, naphthalenes, diphenylethers, and benzenes by utilizing quantitative structure-property relationship (QSPR) techniques. The compounds were classified by applying structure-based clustering methods followed by GA-PLS modeling. In addition, random forest method has been applied to develop more general models. Factors responsible for melting point behavior and predictive ability of each method were discussed.

  15. MRDIS Standalone Central Alarm Station

    SciTech Connect

    2012-09-12

    The MRDIS Standalone Central Alarm Station(MRDIS-CAS} is a software system for receiving, storing, and reviewing radiation data collected by the Mobile Radiation Detection and Identification System (MRDIS}, a mobile radiation scanning system developed for use in foreign ports for the DOE Megaports Initiative. It is designed to run on one of the on board computers in the MRDIS cab. It will collect, store, and display data from the MRDIS without the need for wireless communications or centralized server technology. It is intended to be a lightweight replacement for a distributed Megaports communication system in ports where the necessary communications infrastructure does not exist for a full Megaports communications system.

  16. Alarm sensor apparatus for closures

    DOEpatents

    Carlson, J.A.; Stoddard, L.M.

    1984-01-31

    An alarm sensor apparatus for closures such as doors and windows, and particularly for closures having loose tolerances such as overhead doors, garage doors or the like, the sensor apparatus comprising a pair of cooperating bracket members, one being attached to the door facing or framework and the other to the door member, two magnetic sensor elements carried by said bracket members, the bracket members comprising a pair of cooperating orthogonal guide slots and plates and a stop member engageable with one of the sensors for aligning the sensors with respect to each other in all three orthogonal planes when the door is closed.

  17. Video systems for alarm assessment

    SciTech Connect

    Greenwoll, D.A.; Matter, J.C. ); Ebel, P.E. )

    1991-09-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing closed-circuit television systems for video alarm assessment. There is a section on each of the major components in a video system: camera, lens, lighting, transmission, synchronization, switcher, monitor, and recorder. Each section includes information on component selection, procurement, installation, test, and maintenance. Considerations for system integration of the components are contained in each section. System emphasis is focused on perimeter intrusion detection and assessment systems. A glossary of video terms is included. 13 figs., 9 tabs.

  18. Alarm sensor apparatus for closures

    DOEpatents

    Carlson, James A.; Stoddard, Lawrence M.

    1986-01-01

    An alarm sensor apparatus for closures such as doors and windows, and particularly for closures having loose tolerances such as overhead doors, garage doors or the like, the sensor apparatus comprising a pair of cooperating bracket members, one being attached to the door facing or frame work and the other to the door member, two magnetic sensor elements carried by said bracket members, the bracket members comprising a pair of cooperating orthogonal guide slots and plates and a stop member engageable with one of the sensors for aligning the sensors with respect to each other in all three orthogonal planes when the door is closed.

  19. Public Data Set: A Novel, Cost-Effective, Multi-Point Thomson Scattering System on the Pegasus Toroidal Experiment

    SciTech Connect

    Schlossberg, David J.; Bodner, Grant M.; Reusch, Joshua A.; Bongard, Michael W.; Fonck, Raymond J.; Rodriguez Sanchez, Cuauhtemoc

    2016-09-16

    This public data set contains openly-documented, machine readable digital research data corresponding to figures published in D.J. Schlossberg et. al., 'A Novel, Cost-Effective, Multi-Point Thomson Scattering System on the Pegasus Toroidal Experiment,' Rev. Sci. Instrum. 87, 11E403 (2016).

  20. Set Point Calculations for RAPID Project [Removal of Hold for HNF-5087 and HNF-5088 and HNF-5089

    SciTech Connect

    HICKMAN, G.L.

    1999-09-02

    The Respond and Pump in Days (RAPID) project was initiated to pump part of the contents of tank 241-SY-101 into tanks 241-SY-102. This document establishes the basis for all set points and ranges used in the RAPID project.

  1. Progress in the development of paper-based diagnostics for low-resource point-of-care settings

    PubMed Central

    Byrnes, Samantha; Thiessen, Gregory; Fu, Elain

    2014-01-01

    This Review focuses on recent work in the field of paper microfluidics that specifically addresses the goal of translating the multistep processes that are characteristic of gold-standard laboratory tests to low-resource point-of-care settings. A major challenge is to implement multistep processes with the robust fluid control required to achieve the necessary sensitivity and specificity of a given application in a user-friendly package that minimizes equipment. We review key work in the areas of fluidic controls for automation in paper-based devices, readout methods that minimize dedicated equipment, and power and heating methods that are compatible with low-resource point-of-care settings. We also highlight a focused set of recent applications and discuss future challenges. PMID:24256361

  2. The Set-Point Theory of Well-Being: Negative Results and Consequent Revisions

    ERIC Educational Resources Information Center

    Headey, Bruce

    2008-01-01

    An adequate theory of happiness or subjective well-being (SWB) needs to link at least three sets of variables: stable person characteristics (including personality traits), life events and measures of well-being (life satisfaction, positive affects) and ill-being (anxiety, depression, negative affects). It also needs to be based on long-term data…

  3. Alarm toe switch. [Patent application

    DOEpatents

    Ganyard, F.P.

    1980-11-18

    An alarm toe switch inserted within a shoe for energizing an alarm circuit in a covert manner includes an insole mounting pad into which a miniature reed switch is fixedly molded. An elongated slot perpendicular to the reed switch is formed in the bottom surface of the mounting pad. A permanent cylindrical magnet positioned in the forward portion of the slot with a diameter greater than the pad thickness causes a bump above the pad. A foam rubber block is also positioned in the slot rearwardly of the magnet and holds the magnet in normal inoperative relation. A non-magnetic support plate covers the slot and holds the magnet and foam rubber in the slot. The plate minimizes bending and frictional forces to improve movement of the magnet for reliable switch activation. The bump occupies the knuckle space beneath the big toe. When the big toe is scrunched rearwardly the magnet is moved within the slot relative to the reed switch, thus magnetically activating the switch. When toe pressure is released the foam rubber block forces the magnet back into normal inoperative position to deactivate the reed switch.

  4. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    PubMed

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  5. The serial position, distance, and congruity effects of reference point setting in comparative judgments.

    PubMed

    Jou, Jerwen

    2010-01-01

    This study tested the hypothesis that the serial position function in serial order memory derives from a gradient of activation strength, with the end anchor point having the highest strength and accessibility. Subjects memorized an ordered series of names and were tested on their memory of the order with a comparative judgment task. In Experiment 1, a traditional comparative judgment task was used in which they chose the one member in a pair that was either higher or lower in the ranking on the attribute dimension. The 3 typical effects from comparative judgment for serial items--the bowed serial position function, the distance effect, and the congruity effect--were obtained. In Experiment 2, subjects were instructed to choose the item either closer to or farther from the middle reference point of the series. Remarkably different forms of the 3 effects were obtained. Most notable was a deep drop in the middle of the RT function, supporting the activation gradient hypothesis but further separating the role of the reference point from that of the endpoints in the assumption of the activation strength gradient theories. The findings also generalized the concept of each of these 3 effects.

  6. Beyond Maximum Independent Set: AN Extended Model for Point-Feature Label Placement

    NASA Astrophysics Data System (ADS)

    Haunert, Jan-Henrik; Wolff, Alexander

    2016-06-01

    Map labeling is a classical problem of cartography that has frequently been approached by combinatorial optimization. Given a set of features in the map and for each feature a set of label candidates, a common problem is to select an independent set of labels (that is, a labeling without label-label overlaps) that contains as many labels as possible and at most one label for each feature. To obtain solutions of high cartographic quality, the labels can be weighted and one can maximize the total weight (rather than the number) of the selected labels. We argue, however, that when maximizing the weight of the labeling, interdependences between labels are insufficiently addressed. Furthermore, in a maximum-weight labeling, the labels tend to be densely packed and thus the map background can be occluded too much. We propose extensions of an existing model to overcome these limitations. Since even without our extensions the problem is NP-hard, we cannot hope for an efficient exact algorithm for the problem. Therefore, we present a formalization of our model as an integer linear program (ILP). This allows us to compute optimal solutions in reasonable time, which we demonstrate for randomly generated instances.

  7. The Impact of Systematic Point-of-Care Ultrasound on Management of Patients in a Resource-Limited Setting.

    PubMed

    Stanley, Alastair; Wajanga, Bahati M K; Jaka, Hyasinta; Purcell, Rachael; Byrne, Lauren; Williams, Felicity; Rypien, Candace; Sharpe, Abigail; Laws, Patrick; Faustine, Lucas; Leeme, Tshepo; Mwabutwa, Emmanuel; Peck, Robert; Stephens, Matthew; Kaminstein, Daniel

    2017-02-08

    Although target point-of-care (POC) ultrasonography has been shown to benefit patients in resource-limited settings, it is not clear whether a systematic POC ultrasound assessment in these settings can also lead to similar changes in patient management. A predefined systematic set of POC ultrasound scans were performed on inpatients at a tertiary referral hospital in Tanzania to see if this resulted in changes to patient management. Of the 55 patients scanned, an abnormality was detected in 75% (N = 41), and a change in patient management was recommended or implemented on the basis of POC ultrasound findings in 53% (N = 29). The main impact was earlier initiation of treatment due to more rapid and accurate diagnosis. Further research is warranted to determine whether systematic POC ultrasonography would result in improved patient outcomes in resource-limited settings.

  8. A short guide to pure point diffraction in cut-and-project sets

    NASA Astrophysics Data System (ADS)

    Richard, Christoph; Strungaru, Nicolae

    2017-04-01

    We briefly review the diffraction of quasicrystals and then give an elementary alternative proof of the diffraction formula for regular cut-and-project sets, which is based on Bochner’s theorem from Fourier analysis. This clarifies a common view that the diffraction of a quasicrystal is determined by the diffraction of its underlying lattice. To illustrate our approach, we will also treat a number of well-known explicitly solvable examples. We dedicate this work to Tony Guttmann on the occasion of his 70th birthday

  9. Barriers to Point-of-Care Testing in India: Results from Qualitative Research across Different Settings, Users and Major Diseases

    PubMed Central

    Engel, Nora; Ganesh, Gayatri; Patil, Mamata; Yellappa, Vijayashree; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar

    2015-01-01

    Background Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems. Methods In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers), patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors. Results In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is ‘relationships’ among providers and between providers and patients, influenced by the cross-cutting theme of ‘infrastructure’. Challenges with both result in ‘modified practices’ often favouring empirical (symptomatic) treatment over treatment guided by testing. Conclusions Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined

  10. Application of the Reactor Analysis Support Package LWR set-point analysis guidelines

    SciTech Connect

    Engel, R.E.; Sorensen, J.M.; May, R.S.; Doran, K.J.; Trikouros, N.G.; Mozzias, E.S.

    1989-07-01

    Frequently, a situation is encountered in which the technical specification setpoints established by the plant safety analysis are judged to be unacceptable from a plant operational standpoint. This report documents the application of the Electric Power Research Institute (EPRI) Reactor Analysis Support Package (RASP) Light Water Reactor (LWR) setpoint analysis guidelines to provide justification for relaxing the high pressure setpoints at the Oyster Creek Nuclear Generation Station. More Specifically, the plant operation's staff determined that it was desirable to provide increased margin for measurement uncertainties in the high pressure instrument and safety valve setpoints. Previous experience had indicated that there was insufficient margin to justify the desired setpoints using conventional deterministic inputs to the safety analysis and plant performance evaluation process. Therefore, it was determined that the RASP LWR setpoint analysis guidelines, which incorporated the use of a statistical combination of uncertainties methodology, would be used to establish an acceptable set of high pressure setpoints. This report documents the results of applying the RASP setpoint analysis guidelines to provide justification for an acceptable set of high pressure setpoints for the Oyster Creek station. 14 refs., 53 figs., 28 tabs.

  11. Clowning in Health Care Settings: The Point of View of Adults.

    PubMed

    Dionigi, Alberto; Canestrari, Carla

    2016-08-01

    Within the past decade, there has been a surge of interest in investigating the effects of clown intervention in a large variety of clinical settings. Many studies have focused on the effects of clown intervention on children. However, few studies have investigated clowning effects on adults. This paper presents an overview of the concept of medical clowning followed by a literature review conducted on the empirical studies drawn from three data bases (PubMed, PsycINFO, and Google Scholar), with the aim of mapping and discussing the evidence of clowning effects on non-children, namely adults. The following areas were investigated: Adult and elderly patients (mainly those with dementia), observers of clowning, namely non-hospitalized adults who are at the hospital as relatives of patients or health-care staff, and finally clowns themselves. The main results are that 1) clown intervention induces positive emotions, thereby enhancing the patient's well-being, reduces psychological symptoms and emotional reactivity, and prompts a decrease in negative emotions, such as anxiety and stress; 2) clown doctors are also well-perceived by relatives and healthcare staff and their presence appears to be useful in creating a lighter atmosphere in the health setting; 3) few pilot studies have been conducted on clown doctors and this lacuna represents a subject for future research.

  12. Clowning in Health Care Settings: The Point of View of Adults

    PubMed Central

    Dionigi, Alberto; Canestrari, Carla

    2016-01-01

    Within the past decade, there has been a surge of interest in investigating the effects of clown intervention in a large variety of clinical settings. Many studies have focused on the effects of clown intervention on children. However, few studies have investigated clowning effects on adults. This paper presents an overview of the concept of medical clowning followed by a literature review conducted on the empirical studies drawn from three data bases (PubMed, PsycINFO, and Google Scholar), with the aim of mapping and discussing the evidence of clowning effects on non-children, namely adults. The following areas were investigated: Adult and elderly patients (mainly those with dementia), observers of clowning, namely non-hospitalized adults who are at the hospital as relatives of patients or health-care staff, and finally clowns themselves. The main results are that 1) clown intervention induces positive emotions, thereby enhancing the patient’s well-being, reduces psychological symptoms and emotional reactivity, and prompts a decrease in negative emotions, such as anxiety and stress; 2) clown doctors are also well-perceived by relatives and healthcare staff and their presence appears to be useful in creating a lighter atmosphere in the health setting; 3) few pilot studies have been conducted on clown doctors and this lacuna represents a subject for future research. PMID:27547261

  13. On Chinese earthquake history - An attempt to model an incomplete data set by point process analysis

    USGS Publications Warehouse

    Lee, W.H.K.; Brillinger, D.R.

    1979-01-01

    Since the 1950s, the Academia Sinica in Peking, People's Republic of China, has carried out extensive research on the Chinese earthquake history. With a historical record dating back some 3000 years, a wealth of information on Chinese earthquakes exists. Despite this monumental undertaking by the Academia Sinica, much work is still necessary to correct the existing earthquake data for historical changes in population, customs, modes of communication, and dynasties. In this paper we report on the status of our investigation of Chinese earthquake history and present some preliminary results. By applying point process analysis of earthquakes in 'Central China', we found suggestions of (1) lower earthquake activity at intervals of about 175 years and 375 years, and (2) higher earthquake activity at an interval of about 300 years. ?? 1979 Birkha??user Verlag.

  14. Sampling Point Compliance Tests for 325 Building at Set-Back Flow Conditions

    SciTech Connect

    Ballinger, Marcel Y.; Glissmeyer, John A.; Barnett, J. Matthew; Recknagle, Kurtis P.; Yokuda, Satoru T.

    2011-05-31

    The stack sampling system at the 325 Building (Radiochemical Processing Laboratory [RPL]) was constructed to comply with the American National Standards Institute’s (ANSI’s) Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities (ANSI N13.1-1969). This standard provided prescriptive criteria for the location of radionuclide air-sampling systems. In 1999, the standard was revised (Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities [ANSI/Health Physics Society [HPS] 13.1-1999]) to provide performance-based criteria for the location of sampling systems. Testing was conducted for the 325 Building stack to determine whether the sampling system would meet the updated criteria for uniform air velocity and contaminant concentration in the revised ANSI/HPS 13.1-1999 standard under normal operating conditions (Smith et al. 2010). Measurement results were within criteria for all tests. Additional testing and modeling was performed to determine whether the sampling system would meet criteria under set-back flow conditions. This included measurements taken from a scale model with one-third of the exhaust flow and computer modeling of the system with two-thirds of the exhaust flow. This report documents the results of the set-back flow condition measurements and modeling. Tests performed included flow angularity, uniformity of velocity, gas concentration, and particle concentration across the duct at the sampling location. Results are within ANSI/HPS 13.1-1999 criteria for all tests. These tests are applicable for the 325 Building stack under set-back exhaust flow operating conditions (980 - 45,400 cubic feet per minute [cfm]) with one fan running. The modeling results show that criteria are met for all tests using a two-fan configuration exhaust (flow modeled at 104,000 cfm). Combined with the results from the earlier normal operating conditions, the ANSI/HPS 13.1-1999 criteria for all tests

  15. Complementary lowering of the behavioural and physiological thermoregulatory set-points by tetrodotoxin and saxitoxin in the cat.

    PubMed

    Clark, W G; Lipton, J M

    1974-04-01

    1. Injections of tetrodotoxin or saxitoxin (25 ng in 0.10 ml.) into a lateral cerebral ventricle caused deep body temperature of cats to fall approximately the same amount (2 degrees C) whether the animals were resting in the cold (4 degrees C) or were responding to escape heat.2. Continuous exposure to heat either prevented the hypothermic response or enhanced the level of tachypnoea required to lower body temperature. Tetrodotoxin also caused hypothermia when an animal was lever pressing to obtain heat in the cold environment.3. These results provide evidence that agents which alter the set-point for physiological thermoregulatory activity produce a complementary shift in the behavioural set-point as well.

  16. LiveWire interactive boundary extraction algorithm based on Haar wavelet transform and control point set direction search

    NASA Astrophysics Data System (ADS)

    Cheng, Jun; Zhang, Jun; Tian, Jinwen

    2015-12-01

    Based on deep analysis of the LiveWire interactive boundary extraction algorithm, a new algorithm focusing on improving the speed of LiveWire algorithm is proposed in this paper. Firstly, the Haar wavelet transform is carried on the input image, and the boundary is extracted on the low resolution image obtained by the wavelet transform of the input image. Secondly, calculating LiveWire shortest path is based on the control point set direction search by utilizing the spatial relationship between the two control points users provide in real time. Thirdly, the search order of the adjacent points of the starting node is set in advance. An ordinary queue instead of a priority queue is taken as the storage pool of the points when optimizing their shortest path value, thus reducing the complexity of the algorithm from O[n2] to O[n]. Finally, A region iterative backward projection method based on neighborhood pixel polling has been used to convert dual-pixel boundary of the reconstructed image to single-pixel boundary after Haar wavelet inverse transform. The algorithm proposed in this paper combines the advantage of the Haar wavelet transform and the advantage of the optimal path searching method based on control point set direction search. The former has fast speed of image decomposition and reconstruction and is more consistent with the texture features of the image and the latter can reduce the time complexity of the original algorithm. So that the algorithm can improve the speed in interactive boundary extraction as well as reflect the boundary information of the image more comprehensively. All methods mentioned above have a big role in improving the execution efficiency and the robustness of the algorithm.

  17. 46 CFR 95.16-45 - Pre-discharge alarms and time delay devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of -0/+20 percent of the rated time delay period throughout the operating temperature range and range of delay settings. (b) The pre-discharge alarm must: (1) Sound for the duration of the time delay;...

  18. 46 CFR 95.16-45 - Pre-discharge alarms and time delay devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of -0/+20 percent of the rated time delay period throughout the operating temperature range and range of delay settings. (b) The pre-discharge alarm must: (1) Sound for the duration of the time delay;...

  19. Mouse alarm pheromone shares structural similarity with predator scents

    PubMed Central

    Brechbühl, Julien; Moine, Fabian; Klaey, Magali; Nenniger-Tosato, Monique; Hurni, Nicolas; Sporkert, Frank; Giroud, Christian; Broillet, Marie-Christine

    2013-01-01

    Sensing the chemical warnings present in the environment is essential for species survival. In mammals, this form of danger communication occurs via the release of natural predator scents that can involuntarily warn the prey or by the production of alarm pheromones by the stressed prey alerting its conspecifics. Although we previously identified the olfactory Grueneberg ganglion as the sensory organ through which mammalian alarm pheromones signal a threatening situation, the chemical nature of these cues remains elusive. We here identify, through chemical analysis in combination with a series of physiological and behavioral tests, the chemical structure of a mouse alarm pheromone. To successfully recognize the volatile cues that signal danger, we based our selection on their activation of the mouse olfactory Grueneberg ganglion and the concomitant display of innate fear reactions. Interestingly, we found that the chemical structure of the identified mouse alarm pheromone has similar features as the sulfur-containing volatiles that are released by predating carnivores. Our findings thus not only reveal a chemical Leitmotiv that underlies signaling of fear, but also point to a double role for the olfactory Grueneberg ganglion in intraspecies as well as interspecies communication of danger. PMID:23487748

  20. When one is not enough: prevalence and characteristics of homes not adequately protected by smoke alarms

    PubMed Central

    Peek-Asa, C; Allareddy, V; Yang, J; Taylor, C; Lundell, J; Zwerling, C

    2005-01-01

    Objective: The National Fire Protection Association (NFPA) has specific recommendations about the number, location, and type of smoke alarms that are needed to provide maximum protection for a household. No previous studies have examined whether or not homes are completely protected according to these guidelines. The authors describe the prevalence and home characteristics associated with compliance to recommendations for smoke alarm installation by the NFPA. Design, setting, and subjects: Data are from the baseline on-site survey of a randomized trial to measure smoke alarm effectiveness. The trial was housed in a longitudinal cohort study in a rural Iowa county. Of 1005 homes invited, 691 (68.8%) participated. Main outcome measures: Information about smoke alarm type, placement, and function, as well as home and occupant characteristics, was collected through an on-site household survey. Results: Although 86.0% of homes had at least one smoke alarm, only 22.3% of homes (approximately one in five) were adequately protected according to NFPA guidelines. Fourteen percent of homes had no functioning smoke alarms. More than half of the homes with smoke alarms did not have enough of them or had installed them incorrectly, and 42.4% of homes with alarms had at least one alarm that did not operate. Homes with at least one high school graduate were nearly four times more likely to be fully protected. Homes that had multiple levels, a basement, or were cluttered or poorly cleaned were significantly less likely to be fully protected. Conclusion: These findings indicate that consumers may not be knowledgeable about the number of alarms they need or how to properly install them. Occupants are also not adequately maintaining the alarms that are installed. PMID:16326772

  1. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) Spaces which are protected by a carbon... audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to... sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and...

  2. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  3. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  4. Display-And-Alarm Circuit For Accelerometer

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  5. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  6. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  7. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  8. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  9. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  10. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  11. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) Spaces which are protected by a carbon... audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to... sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and...

  12. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  13. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  14. Residential smoke alarms and fire escape plans.

    PubMed Central

    Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F

    1998-01-01

    OBJECTIVE: To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. METHODS: The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. RESULTS: Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. CONCLUSIONS: Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household. PMID:9769771

  15. Evaluation of criticality alarm response at the WEMCO Fernald site

    SciTech Connect

    Broadhead, B.L.; Childs, R.L.; Westfall, R.M.; Parks, C.V.

    1992-11-01

    This work quantifies the expected dose rates at a series of criticality alarm locations due to several postulated criticality accidents at the Westinghouse Environmental MANAGEMENT COMPANY OF OHIO (WEMCO) Fernald site. One- and two-dimensional discrete- ordinates calculations were performed for seven different shielding configurations using leakage spectra corresponding to two specific postulated critical events. In addition, an estimate of the gaseous fission products released during the hypothetical accident was made using ORIGEN-S point-depletion code.

  16. Design of portable valuables touch alarm circuit

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao

    2017-03-01

    In this paper, the name of the alarm is portable touch burglar alarm. It not only has the advantages of high sensitivity, small size and light weight, but it is easy on the trigger, the circuit is simple and easy to be implemented, besides, it works stably. This alarm is featured with simple design, convenient use, strong flexibility and reliable performance, thus it can be installed on the door or window and even can be carried on human's body. When the human body touches the metal valuables that need to be protected, the device will start the alarm equipment so as to make the bell keep ringing, and the alarm sound stops until the power is cut off.

  17. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Audible and visual alarms. 154.1365 Section 154.1365... Instrumentation § 154.1365 Audible and visual alarms. (a) Each audible alarm must have an arrangement that allows... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only...

  18. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1... ALARM SYSTEMS AND EQUIPMENT Automatic Sprinkler Systems § 113.20-1 Sprinkler alarm system. Each sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart...

  19. Alarming features: birds use specific acoustic properties to identify heterospecific alarm calls

    PubMed Central

    Fallow, Pamela M.; Pitcher, Benjamin J.; Magrath, Robert D.

    2013-01-01

    Vertebrates that eavesdrop on heterospecific alarm calls must distinguish alarms from sounds that can safely be ignored, but the mechanisms for identifying heterospecific alarm calls are poorly understood. While vertebrates learn to identify heterospecific alarms through experience, some can also respond to unfamiliar alarm calls that are acoustically similar to conspecific alarm calls. We used synthetic calls to test the role of specific acoustic properties in alarm call identification by superb fairy-wrens, Malurus cyaneus. Individuals fled more often in response to synthetic calls with peak frequencies closer to those of conspecific calls, even if other acoustic features were dissimilar to that of fairy-wren calls. Further, they then spent more time in cover following calls that had both peak frequencies and frequency modulation rates closer to natural fairy-wren means. Thus, fairy-wrens use similarity in specific acoustic properties to identify alarms and adjust a two-stage antipredator response. Our study reveals how birds respond to heterospecific alarm calls without experience, and, together with previous work using playback of natural calls, shows that both acoustic similarity and learning are important for interspecific eavesdropping. More generally, this study reconciles contrasting views on the importance of alarm signal structure and learning in recognition of heterospecific alarms. PMID:23303539

  20. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  1. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  2. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  3. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  4. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  5. Point-of-care testing for HIV in an Irish prison setting: results from three major Irish prisons.

    PubMed

    Bannan, Ciaran L; Lynch, Pamela A; Conroy, Emmett P; O'Dea, Siobhan; Surah, Saloni; Betts-Symonds, Graham; Lyons, Fiona E

    2016-10-01

    HIV is more prevalent in the prison population compared to the general population. Prison inmates are at an increased risk of blood-borne infections. Considerable stigma has been documented amongst inmates with HIV infection. In collaboration with the schools, healthcare facilities, prison authorities and inmate Irish Red Cross groups in Wheatfield, Cloverhill and Mountjoy prisons in Dublin, Ireland, the Department of Genito Urinary Medicine and Infectious Diseases at St James' Hospital in Dublin developed a campaign for raising awareness of HIV, educating inmates about HIV and tackling HIV stigma. Following this campaign, large-scale point-of-care testing for HIV was offered over a short period. In total, 741 inmates were screened for HIV. One inmate tested positive for HIV. We experienced a large number of invalid test results, requiring formal laboratory serum testing, and a small number of false positive results. Large-scale point-of-care testing in the Irish prison setting is acceptable and achievable.

  6. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Access to the bilge alarm must require the breaking of a seal, except when— (1) Re-zeroing the instrument...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing...

  7. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Access to the bilge alarm must require the breaking of a seal, except when— (1) Re-zeroing the instrument...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing...

  8. Evaluation of alarm systems for medical equipment.

    PubMed

    Hyman, W A

    1982-01-01

    The provision of automatic alarm systems on medical equipment is generally designed to supplement the user's ability to monitor a variety of device and patient variables simultaneously. The potential value of such systems in improving the safety and efficacy of medical care is accompanied by the potential for false reliance on or other misuse of the alarm systems. Therefore the alarm provisions become an important aspect of clinical engineering assessment of equipment with respect to selection, user training, hazard analysis, and the provision of effective and appropriate preventive maintenance programs.

  9. Multiple pass collaborative search in the presence of false alarms

    NASA Astrophysics Data System (ADS)

    Baylog, John G.; Wettergren, Thomas A.

    2015-05-01

    This paper addresses the planning of multiple collaborative searchers that are seeking to find hidden objects (i.e. mines) in environments where the sensor detection process is prone to false alarms. In such situations it is anticipated that collaboration between searchers that are examining the same sub-regions may be used to mitigate the impact of false alarms. A standard Receiver Operator Characteristic (ROC) analysis is conducted and the mapping between a single search pass ROC curve and an equivalent multiple search pass representation within a cumulative probability space is discussed. This mapping produces an analogous family of ROC curves for an increasing number of search passes using either a first detection or multiple occurrence performance criteria. The migration of ROC operating points is analyzed as additional search passes are included within a search plan and suggests the need to coordinate search effort with operating point selection. The mapping from waiting time event probabilities to a total error performance criterion weighted according to the cumulative probabilities of missed detection and false alarm is developed. Details of its application for threshold optimization within search planning is discussed and numerical results are provided to demonstrate the usefulness of the models in evaluating performance trade-offs.

  10. Uranyl nitrate source characterization for criticality alarm placement analysis

    SciTech Connect

    Scott, C.T.; Pevey, R.E.; Angelo, P.L.

    2000-07-01

    This work concerns the development of an equivalent point source to represent the radiation release from a highly enriched uranyl nitrate criticality accident. This source will be used in a subsequent deep penetration criticality alarm placement analysis. It is more efficient to separate the source characterization analysis from the alarm placement analysis because (a) the industry standard tools for doing the two analyses are different (criticality safety code versus deep penetration shielding code), (b) the industry standard libraries commonly used for the two analyses are different (neutron library versus coupled neutron/photon library), and (c) the calculational approaches for the two analyses are different (neutronic critical {kappa}{sub eff} eigenvalue search versus deep penetration dose determination).

  11. Testosterone Induces Erythrocytosis via Increased Erythropoietin and Suppressed Hepcidin: Evidence for a New Erythropoietin/Hemoglobin Set Point

    PubMed Central

    Travison, Thomas G.; Basaria, Shehzad; Davda, Maithili N.; Guo, Wen; Li, Michelle; Connor Westfall, John; Bae, Harold; Gordeuk, Victor; Bhasin, Shalender

    2014-01-01

    Background. The mechanisms by which testosterone increases hemoglobin and hematocrit remain unclear. Methods. We assessed the hormonal and hematologic responses to testosterone administration in a clinical trial in which older men with mobility limitation were randomized to either placebo or testosterone gel daily for 6 months. Results. The 7%–10% increase in hemoglobin and hematocrit, respectively, with testosterone administration was associated with significantly increased erythropoietin (EPO) levels and decreased ferritin and hepcidin levels at 1 and 3 months. At 6 months, EPO and hepcidin levels returned toward baseline in spite of continued testosterone administration, but EPO levels remained nonsuppressed even though elevated hemoglobin and hematocrit higher than at baseline, suggesting a new set point. Consistent with increased iron utilization, soluble transferrin receptor (sTR) levels and ratio of sTR/log ferritin increased significantly in testosterone-treated men. Hormonal and hematologic responses were similar in anemic participants. The majority of testosterone-treated anemic participants increased their hemoglobin into normal range. Conclusions. Testosterone-induced increase in hemoglobin and hematocrit is associated with stimulation of EPO and reduced ferritin and hepcidin concentrations. We propose that testosterone stimulates erythropoiesis by stimulating EPO and recalibrating the set point of EPO in relation to hemoglobin and by increasing iron utilization for erythropoiesis. PMID:24158761

  12. Alarm Systems: Library Confounds Criminal Capers.

    ERIC Educational Resources Information Center

    Gjettum, Pamela

    1978-01-01

    Tells the story of a small town library faced with the problem of preventing nuisance burglaries of the type becoming more and more common. The problems of selecting the right type of alarm system are discussed. (JPF)

  13. Giving radioiodine? Think about airport security alarms.

    PubMed

    Kaniuka-Jakubowska, S; Lewczuk, A; Mizan-Gross, K; Obołończyk, L; Lass, P; Sworczak, K

    2012-01-01

    An increased sensitivity of airport detectors, a growing number of isotopic tests, and globalization of the society have raised a number of false positive radioactive alarms at airports and public places. This paper presents two new cases of patients who triggered airport security alarms after receiving 740MBq of (131)I for non-toxic goitre and attempts to compare surprisingly limited literature concerning this problem. A 57-year-old man triggered a security alarm at three different airports on the 17th, 28th, and 31st day after radioiodine exposure. Interestingly enough, in the meantime, on the 18th and 22nd day, no radiation was detected in him at the airport where he was twice detained as a source of radiation later on. The second case presents a 45-year-old woman who activated security alarm detectors while crossing a border on her coach trip 28 days after radioiodine administration.

  14. SU-E-P-08: Alarming Range of Seed Activities Ordered for I-125 Plaque Brachytherapy

    SciTech Connect

    Merz, B

    2014-06-01

    Purpose: To investigate the variation in I-125 seed activities ordered by various clinics for their plaque brachytherapy cases under a standardized set of assumptions. Methods: A majority of the plaque programs in North America were contacted and a survey was designed to give a few standardized cases to allow inter-comparison of seed activities ordered. Tumor dose, treatment duration, number of seeds, plaque, and tumor apex were held constant in order to reveal differences in prescription point, seed type, and seed activity. Results: While the survey is presently underway, preliminary results show alarmingly wide variations between centers. Differences up to 45% have been found with 15% differences being common. Conclusion: Though knowledge of the TG-43 dose calculation formalism is common, a number of factors in the field of plaque brachytherapy lead to alarming differences in activity of I-125 seeds being ordered for a given tumor. Knowledge of the present reality of widely varying treatment activities, and thus doses to tumor and normal structures, should serve as motivation for centers involved in this modality to review their programs with others in the community and share their experiences.

  15. Method and basis set dependence of anharmonic ground state nuclear wave functions and zero-point energies: application to SSSH.

    PubMed

    Kolmann, Stephen J; Jordan, Meredith J T

    2010-02-07

    One of the largest remaining errors in thermochemical calculations is the determination of the zero-point energy (ZPE). The fully coupled, anharmonic ZPE and ground state nuclear wave function of the SSSH radical are calculated using quantum diffusion Monte Carlo on interpolated potential energy surfaces (PESs) constructed using a variety of method and basis set combinations. The ZPE of SSSH, which is approximately 29 kJ mol(-1) at the CCSD(T)/6-31G* level of theory, has a 4 kJ mol(-1) dependence on the treatment of electron correlation. The anharmonic ZPEs are consistently 0.3 kJ mol(-1) lower in energy than the harmonic ZPEs calculated at the Hartree-Fock and MP2 levels of theory, and 0.7 kJ mol(-1) lower in energy at the CCSD(T)/6-31G* level of theory. Ideally, for sub-kJ mol(-1) thermochemical accuracy, ZPEs should be calculated using correlated methods with as big a basis set as practicable. The ground state nuclear wave function of SSSH also has significant method and basis set dependence. The analysis of the nuclear wave function indicates that SSSH is localized to a single symmetry equivalent global minimum, despite having sufficient ZPE to be delocalized over both minima. As part of this work, modifications to the interpolated PES construction scheme of Collins and co-workers are presented.

  16. Conspecific injury raises an alarm in medaka

    PubMed Central

    Mathuru, Ajay S.

    2016-01-01

    In the late 1930s, Karl von Frisch reported that semiochemicals released upon injury, act as alarm substances (Schreckstoff) in fish. In Ostariophysi species, club cells in the epidermis are believed to contain cues related to alarm substance; however, the function of club cells, primarily as reservoirs of alarm substance has been debated. Here, I describe an alarm response in the Japanese rice fish Oryzias latipes (medaka), a member of the order Beloniformes. The response to alarm substance (Schreckreaction) in medaka is characterized by bouts of immobility and an increase in cortisol levels within minutes of exposure to conspecific skin extract. Histological analysis, however, suggests that club cells are either rare or absent in the medaka epidermis. In addition to describing an uncharacterized behavior in a vertebrate popular for genetic and developmental studies, these results support the hypothesis that the primary function of epidermal club cells may be unrelated to a role as alarm substance cells. The existence of similar behavioral responses in two evolutionarily distant but well established laboratory models, the zebrafish and the medaka, offers the possibility of comparative analyses of neural circuits encoding innate fear. PMID:27824153

  17. A rule-based approach for the correlation of alarms to support Disaster and Emergency Management

    NASA Astrophysics Data System (ADS)

    Gloria, M.; Minei, G.; Lersi, V.; Pasquariello, D.; Monti, C.; Saitto, A.

    2009-04-01

    Key words: Simple Event Correlator, Agent Platform, Ontology, Semantic Web, Distributed Systems, Emergency Management The importance of recognition of emergency's typology to control the critical situation for security of citizens has been always recognized. It follows this aspect is very important for proper management of a hazardous event. In this work we present a solution for the recognition of emergency's typology adopted by an Italian research project, called CI6 (Centro Integrato per Servizi di Emergenza Innovativi). In our approach, CI6 receives alarms by citizen or people involved in the work (for example: police, operator of 112, and so on). CI6 represents any alarm by a set of information, including a text that describes it and obtained when the user points out the danger, and a pair of coordinates for its location. The system realizes an analysis of text and automatically infers information on the type of emergencies by means a set of parsing rules and rules of inference applied by a independent module: a correlator of events based on their log and called Simple Event Correlator (SEC). SEC, integrated in CI6's platform, is an open source and platform independent event correlation tool. SEC accepts input both files and text derived from standard input, making it flexible because it can be matched to any application that is able to write its output to a file stream. The SEC configuration is stored in text files as rules, each rule specifying an event matching condition, an action list, and optionally a Boolean expression whose truth value decides whether the rule can be applied at a given moment. SEC can produce output events by executing user-specified shell scripts or programs, by writing messages to files, and by various other means. SEC has been successfully applied in various domains like network management, system monitoring, data security, intrusion detection, log file monitoring and analysis, etc; it has been used or integrated with many

  18. An Set-Free, All Digital Controlled Point-of-Load Regulator for Next Generation Power Systems: ADC-POL

    NASA Technical Reports Server (NTRS)

    Adell, Philippe C.; Liu, Tao; Vermeire, Bert; Bakkaloglu, Bertan; Aveline, David

    2011-01-01

    This paper presents a digitally controlled programmable point-of-load regulator for next-generation power systems. A novel digital control scheme was designed to minimize single-event effect (SEE)-induced transient effects. By effectively programming the loop transmission, the POL can trade off transient response time with SET robustness. The IC works with 1 to 5.5 V input voltage, 1-4.5V regulated output voltage, high efficiency (peak efficiency at 94%) and power of up to 5 W. The design was fabricated in the AMI i2t100 0.7 mu m complimentary, metal-oxide semiconductor (CMOS) process and characterized with the Jet Propulsion Laboratory (JPL) pulsed laser system.

  19. HIV DNA Set Point is Rapidly Established in Acute HIV Infection and Dramatically Reduced by Early ART.

    PubMed

    Ananworanich, Jintanat; Chomont, Nicolas; Eller, Leigh Ann; Kroon, Eugene; Tovanabutra, Sodsai; Bose, Meera; Nau, Martin; Fletcher, James L K; Tipsuk, Somporn; Vandergeeten, Claire; O'Connell, Robert J; Pinyakorn, Suteeraporn; Michael, Nelson; Phanuphak, Nittaya; Robb, Merlin L

    2016-09-01

    HIV DNA is a marker of HIV persistence that predicts HIV progression and remission, but its kinetics in early acute HIV infection (AHI) is poorly understood. We longitudinally measured the frequency of peripheral blood mononuclear cells harboring total and integrated HIV DNA in 19 untreated and 71 treated AHI participants, for whom 50 were in the earliest Fiebig I/II (HIV IgM-) stage, that is ≤2weeks from infection. Without antiretroviral therapy (ART), HIV DNA peaked at 2weeks after enrollment, reaching a set-point 2weeks later with little change thereafter. There was a marked divergence of HIV DNA values between the untreated and treated groups that occurred within the first 2weeks of ART and increased with time. ART reduced total HIV DNA levels by 20-fold after 2weeks and 316-fold after 3years. Therefore, very early ART offers the opportunity to significantly reduce the frequency of cells harboring HIV DNA.

  20. A New Set of Chemical Starting Points with Plasmodium falciparum Transmission-Blocking Potential for Antimalarial Drug Discovery

    PubMed Central

    Almela, Maria Jesus; Lozano, Sonia; Lelièvre, Joël; Colmenarejo, Gonzalo; Coterón, José Miguel; Rodrigues, Janneth; Gonzalez, Carolina; Herreros, Esperanza

    2015-01-01

    The discovery of new antimalarials with transmission blocking activity remains a key issue in efforts to control malaria and eventually eradicate the disease. Recently, high-throughput screening (HTS) assays have been successfully applied to Plasmodium falciparum asexual stages to screen millions of compounds, with the identification of thousands of new active molecules, some of which are already in clinical phases. The same approach has now been applied to identify compounds that are active against P. falciparum gametocytes, the parasite stage responsible for transmission. This study reports screening results for the Tres Cantos Antimalarial Set (TCAMS), of approximately 13,533 molecules, against P. falciparum stage V gametocytes. Secondary confirmation and cytotoxicity assays led to the identification of 98 selective molecules with dual activity against gametocytes and asexual stages. Hit compounds were chemically clustered and analyzed for appropriate physicochemical properties. The TCAMS chemical space around the prioritized hits was also studied. A selection of hit compounds was assessed ex vivo in the standard membrane feeding assay and demonstrated complete block in transmission. As a result of this effort, new chemical structures not connected to previously described antimalarials have been identified. This new set of compounds may serve as starting points for future drug discovery programs as well as tool compounds for identifying new modes of action involved in malaria transmission. PMID:26317851

  1. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  2. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  3. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  4. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  5. Alarm acknowledgement in a nuclear plant control room

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    Alarm acknowledgment can be made not only at the alarm tile array of a given console but via other touch sensitive alarm indications in the screen displays of the monitoring system at the same or other consoles; also, touching one tile can acknowledge multiple alarm sources.

  6. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  7. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b)...

  8. 46 CFR 169.732 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.”...

  9. 46 CFR 108.627 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next...

  10. 46 CFR 169.732 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.”...

  11. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b)...

  12. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  13. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  14. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  15. 46 CFR 108.627 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next...

  16. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Bilge alarm: Design specification. 162.050-33 Section....050-33 Bilge alarm: Design specification. (a) This section contains requirements that apply to bilge alarms. (b) Each bilge alarm must be designed to meet the requirements for an oil content meter in §...

  17. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Bilge alarm: Design specification. 162.050-33 Section....050-33 Bilge alarm: Design specification. (a) This section contains requirements that apply to bilge alarms. (b) Each bilge alarm must be designed to meet the requirements for an oil content meter in §...

  18. Design of a Novel Low Cost Point of Care Tampon (POCkeT) Colposcope for Use in Resource Limited Settings

    PubMed Central

    Lam, Christopher T.; Krieger, Marlee S.; Gallagher, Jennifer E.; Asma, Betsy; Muasher, Lisa C.; Schmitt, John W.; Ramanujam, Nimmi

    2015-01-01

    Introduction Current guidelines by WHO for cervical cancer screening in low- and middle-income countries involves visual inspection with acetic acid (VIA) of the cervix, followed by treatment during the same visit or a subsequent visit with cryotherapy if a suspicious lesion is found. Implementation of these guidelines is hampered by a lack of: trained health workers, reliable technology, and access to screening facilities. A low cost ultra-portable Point of Care Tampon based digital colposcope (POCkeT Colposcope) for use at the community level setting, which has the unique form factor of a tampon, can be inserted into the vagina to capture images of the cervix, which are on par with that of a state of the art colposcope, at a fraction of the cost. A repository of images to be compiled that can be used to empower front line workers to become more effective through virtual dynamic training. By task shifting to the community setting, this technology could potentially provide significantly greater cervical screening access to where the most vulnerable women live. The POCkeT Colposcope’s concentric LED ring provides comparable white and green field illumination at a fraction of the electrical power required in commercial colposcopes. Evaluation with standard optical imaging targets to assess the POCkeT Colposcope against the state of the art digital colposcope and other VIAM technologies. Results Our POCkeT Colposcope has comparable resolving power, color reproduction accuracy, minimal lens distortion, and illumination when compared to commercially available colposcopes. In vitro and pilot in vivo imaging results are promising with our POCkeT Colposcope capturing comparable quality images to commercial systems. Conclusion The POCkeT Colposcope is capable of capturing images suitable for cervical lesion analysis. Our portable low cost system could potentially increase access to cervical cancer screening in limited resource settings through task shifting to community

  19. Critical control points for avian influenza A H5N1 in live bird markets in low resource settings.

    PubMed

    Samaan, Gina; Gultom, Anita; Indriani, Risa; Lokuge, Kamalini; Kelly, Paul M

    2011-06-01

    Live bird markets can become contaminated with and become a source of transmission for avian influenza viruses including the highly pathogenic H5N1 strain. Many countries affected by the H5N1-virus have limited resources for programs in environmental health, sanitation and disease control in live bird markets. This study proposes five critical control points (CCPs) to reduce the risk of H5N1-virus contamination in markets in low resource settings. The CCPs were developed based on three surveys conducted in Indonesia: a cross-sectional survey in 119 markets, a knowledge, attitudes and practice survey in 3 markets and a microbiological survey in 83 markets. These surveys assessed poultry workflow, market infrastructure, hygiene and regulatory practices and microbiological contamination with the H5N1-virus. The five CCPs identified were (1) reducing risk of receiving infected birds into the market, (2) reducing the risk of virus spread between different bird flocks in holding cages, (3) reducing surface contamination by isolating slaughter processes from other poultry-related processes, (4) minimizing the potential for contamination during evisceration of carcasses and (5) reducing the risk of surface contamination in the sale zone of the market. To be relevant for low resource settings, the CCPs do not necessitate large infrastructure changes. The CCPs are suited for markets that slaughter poultry and have capacity for daily disposal and removal of solid waste from the market. However, it is envisaged that the CCPs can be adapted for the development of risk-based programs in various settings.

  20. Low Voltage Alarm Apprenticeship. Related Training Modules. 7.1-26.10 Alarm Basics.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet of 70 learning modules on alarm basics is 1 of 8 such packets developed for apprenticeship training for low voltage alarm. Introductory materials are a complete listing of all available modules and a supplementary reference list. Each module contains some or all of these components: goal, performance indicators, study guide (a check…

  1. Low Voltage Alarm Apprenticeship. Related Training Modules. 0.1 History of Alarms.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet of one learning module on the history of alarms is one of eight such packets developed for apprenticeship training for low voltage alarm. Introductory materials are a complete listing of all available modules and a supplementary reference list. Each module contains some or all of these components: goal, performance indicators, study…

  2. Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients

    PubMed Central

    Drew, Barbara J.; Harris, Patricia; Zègre-Hemsey, Jessica K.; Mammone, Tina; Schindler, Daniel; Salas-Boni, Rebeca; Bai, Yong; Tinoco, Adelita; Ding, Quan; Hu, Xiao

    2014-01-01

    Purpose Physiologic monitors are plagued with alarms that create a cacophony of sounds and visual alerts causing “alarm fatigue” which creates an unsafe patient environment because a life-threatening event may be missed in this milieu of sensory overload. Using a state-of-the-art technology acquisition infrastructure, all monitor data including 7 ECG leads, all pressure, SpO2, and respiration waveforms as well as user settings and alarms were stored on 461 adults treated in intensive care units. Using a well-defined alarm annotation protocol, nurse scientists with 95% inter-rater reliability annotated 12,671 arrhythmia alarms. Results A total of 2,558,760 unique alarms occurred in the 31-day study period: arrhythmia, 1,154,201; parameter, 612,927; technical, 791,632. There were 381,560 audible alarms for an audible alarm burden of 187/bed/day. 88.8% of the 12,671 annotated arrhythmia alarms were false positives. Conditions causing excessive alarms included inappropriate alarm settings, persistent atrial fibrillation, and non-actionable events such as PVC's and brief spikes in ST segments. Low amplitude QRS complexes in some, but not all available ECG leads caused undercounting and false arrhythmia alarms. Wide QRS complexes due to bundle branch block or ventricular pacemaker rhythm caused false alarms. 93% of the 168 true ventricular tachycardia alarms were not sustained long enough to warrant treatment. Discussion The excessive number of physiologic monitor alarms is a complex interplay of inappropriate user settings, patient conditions, and algorithm deficiencies. Device solutions should focus on use of all available ECG leads to identify non-artifact leads and leads with adequate QRS amplitude. Devices should provide prompts to aide in more appropriate tailoring of alarm settings to individual patients. Atrial fibrillation alarms should be limited to new onset and termination of the arrhythmia and delays for ST-segment and other parameter alarms should be

  3. Electronic Prescribing at the Point of Care: A Time–Motion Study in the Primary Care Setting

    PubMed Central

    Devine, Emily Beth; Hollingworth, William; Hansen, Ryan N; Lawless, Nathan M; Wilson-Norton, Jennifer L; Martin, Diane P; Blough, David K; Sullivan, Sean D

    2010-01-01

    Objective To evaluate the impact of an ambulatory computerized provider order entry (CPOE) system on the time efficiency of prescribers. Two primary aims were to compare prescribing time between (1) handwritten and electronic (e-) prescriptions and (2) e-prescriptions using differing hardware configurations. Data Sources/Study Setting Primary data on prescribers/staff were collected (2005–2007) at three primary care clinics in a community based, multispecialty health system. Study Design This was a quasi-experimental, direct observation, time–motion study conducted in two phases. In phase 1 (n=69 subjects), each site used a unique combination of CPOE software/hardware (paper-based, desktops in prescriber offices or hallway workstations, or laptops). In phase 2 (n=77), all sites used CPOE software on desktops in examination rooms (at point of care). Data Collection Methods Data were collected using TimerPro software on a Palm device. Principal Findings Average time to e-prescribe using CPOE in the examination room was 69 seconds/prescription-event (new/renewed combined)—25 seconds longer than to handwrite (99.5 percent confidence interval [CI] 12.38), and 24 seconds longer than to e-prescribe at offices/workstations (99.5 percent CI 8.39). Each calculates to 20 seconds longer per patient. Conclusions E-prescribing takes longer than handwriting. E-prescribing at the point of care takes longer than e-prescribing in offices/workstations. Improvements in safety and quality may be worth the investment of time. PMID:19929963

  4. A hybrid semi-automatic method for liver segmentation based on level-set methods using multiple seed points.

    PubMed

    Yang, Xiaopeng; Yu, Hee Chul; Choi, Younggeun; Lee, Wonsup; Wang, Baojian; Yang, Jaedo; Hwang, Hongpil; Kim, Ji Hyun; Song, Jisoo; Cho, Baik Hwan; You, Heecheon

    2014-01-01

    The present study developed a hybrid semi-automatic method to extract the liver from abdominal computerized tomography (CT) images. The proposed hybrid method consists of a customized fast-marching level-set method for detection of an optimal initial liver region from multiple seed points selected by the user and a threshold-based level-set method for extraction of the actual liver region based on the initial liver region. The performance of the hybrid method was compared with those of the 2D region growing method implemented in OsiriX using abdominal CT datasets of 15 patients. The hybrid method showed a significantly higher accuracy in liver extraction (similarity index, SI=97.6 ± 0.5%; false positive error, FPE = 2.2 ± 0.7%; false negative error, FNE=2.5 ± 0.8%; average symmetric surface distance, ASD=1.4 ± 0.5mm) than the 2D (SI=94.0 ± 1.9%; FPE = 5.3 ± 1.1%; FNE=6.5 ± 3.7%; ASD=6.7 ± 3.8mm) region growing method. The total liver extraction time per CT dataset of the hybrid method (77 ± 10 s) is significantly less than the 2D region growing method (575 ± 136 s). The interaction time per CT dataset between the user and a computer of the hybrid method (28 ± 4 s) is significantly shorter than the 2D region growing method (484 ± 126 s). The proposed hybrid method was found preferred for liver segmentation in preoperative virtual liver surgery planning.

  5. Identifying the turning point: using the transtheoretical model of change to map intimate partner violence disclosure in emergency department settings.

    PubMed

    Catallo, Cristina; Jack, Susan M; Ciliska, Donna; Macmillan, Harriet L

    2012-01-01

    Background. The transtheoretical model of change (TTM) was used as a framework to examine the steps that women took to disclose intimate partner violence (IPV) in urban emergency departments. Methods. Mapping methods portrayed the evolving nature of decisions that facilitated or inhibited disclosure. This paper is a secondary analysis of qualitative data from a mixed methods study that explored abused women's decision making process about IPV disclosure. Findings. Change maps were created for 19 participants with movement from the precontemplation to the maintenance stages of the model. Disclosure often occurred after a significant "turning point event" combined with a series of smaller events over a period of time. The significant life event often involved a weighing of options where participants considered the perceived risks against the potential benefits of disclosure. Conclusions. Abused women experienced intrusion from the chaotic nature of the emergency department. IPV disclosure was perceived as a positive experience when participants trusted the health care provider and felt control over their decisions to disclose IPV. Practice Implications. Nurses can use these findings to gauge the readiness of women to disclose IPV in the emergency department setting.

  6. Design of set-point weighting PIλ + Dμ controller for vertical magnetic flux controller in Damavand tokamak.

    PubMed

    Rasouli, H; Fatehi, A

    2014-12-01

    In this paper, a simple method is presented for tuning weighted PI(λ) + D(μ) controller parameters based on the pole placement controller of pseudo-second-order fractional systems. One of the advantages of this controller is capability of reducing the disturbance effects and improving response to input, simultaneously. In the following sections, the performance of this controller is evaluated experimentally to control the vertical magnetic flux in Damavand tokamak. For this work, at first a fractional order model is identified using output-error technique in time domain. For various practical experiments, having desired time responses for magnetic flux in Damavand tokamak, is vital. To approach this, at first the desired closed loop reference models are obtained based on generalized characteristic ratio assignment method in fractional order systems. After that, for the identified model, a set-point weighting PI(λ) + D(μ) controller is designed and simulated. Finally, this controller is implemented on digital signal processor control system of the plant to fast/slow control of magnetic flux. The practical results show appropriate performance of this controller.

  7. Poison and alarm: the Asian hornet Vespa velutina uses sting venom volatiles as an alarm pheromone.

    PubMed

    Cheng, Ya-Nan; Wen, Ping; Dong, Shi-Hao; Tan, Ken; Nieh, James C

    2017-02-15

    In colonial organisms, alarm pheromones can provide a key fitness advantage by enhancing colony defence and warning of danger. Learning which species use alarm pheromone and the key compounds involved therefore enhances our understanding of how this important signal has evolved. However, our knowledge of alarm pheromones is more limited in the social wasps and hornets compared with the social bees and ants. Vespa velutina is an economically important and widespread hornet predator that attacks honey bees and humans. This species is native to Asia and has now invaded Europe. Despite growing interest in V. velutina, it was unknown whether it possessed an alarm pheromone. We show that these hornets use sting venom as an alarm pheromone. Sting venom volatiles were strongly attractive to hornet workers and triggered attacks. Two major venom fractions, consisting of monoketones and diketones, also elicited attack. We used gas chromatography coupled to electroantennographic detection (GC-EAD) to isolate 13 known and 3 unknown aliphatic ketones and alcohols in venom that elicited conspicuous hornet antennal activity. Two of the unknown compounds may be an undecen-2-one and an undecene-2,10-dinone. Three major compounds (heptan-2-one, nonan-2-one and undecan-2-one) triggered attacks, but only nonan-2-one did so at biologically relevant levels (10 hornet equivalents). Nonan-2-one thus deserves particular attention. However, the key alarm releasers for V. velutina remain to be identified. Such identification will help to illuminate the evolution and function of alarm compounds in hornets.

  8. A revival of the alarm system: Making the alarm list useful during incidents

    SciTech Connect

    Larsson, J. E.; Oehman, B.; Calzada, A.; Nihlwing, C.; Jokstad, H.; Kristianssen, L. I.; Kvalem, J.; Lind, M.

    2006-07-01

    In control rooms there are often problems with information overload, which means that the operators may receive more information than they are able to interpret. The most serious information overload occurs in two types of situations. The first is when the operating state of the plant changes, which often gives raise to a shower of alarms and events. Such an alarm shower is expected, but can be dangerous, because it may hide other alarms originating from unrelated faults. The second problem occurs when a fault causes several consequential faults, leading to a so-called alarm cascade. Because the alarms seldom arrive in correct time order, it can be very difficult to analyze such a cascade, and the information overload occurs in exactly the moment when a potentially dangerous situation starts. In an ongoing project, GoalArt and IFE are cooperating in testing and evaluating GoalArt's methods for alarm reduction and root cause analysis. The testing comprises two specific algorithms, root cause analysis and state-based alarm priority. The GoalArt system has been integrated with the HAMBO simulator so that operators can evaluate the algorithms on-line. (authors)

  9. ALARM STRATEGY AND COMPLEXITY: PREDICTIONS OF OPERATOR RESPONSE

    SciTech Connect

    Austin Ragsdale; Roger Lew; Brian Dyre; Ronald Boring; David Gertman

    2012-07-01

    Decision support for operators is not new, and much has been written regarding the potential usefulness of digital support systems and alarm filtering strategies. However, determining the appropriate characteristics of decision support tools is difficult, especially when alarms can vary in the manner which diagnostic information is formulated and displayed and when event scenario types are complex and numerous. When first reviewed, the advantages or disadvantages of a particular alarm approach may not be apparent to the designer or analyst. The present research focuses on the review of two particular alarm strategies, binary alarm type (BAT) and likelihood alarm type (LAT), and reviews their influence upon accuracy, bias, and trust for tasks performed at a computer workstation capable of replicating a series of control-room-like alarms. The findings are discussed in terms of the of the performance advantages of likelihood alarm technology and related research as an aid to the alarm design process.

  10. Mianserin affects alarm reaction to conspecific chemical alarm cues in Nile tilapia.

    PubMed

    Barreto, Rodrigo Egydio

    2017-02-01

    In this study, I show that mianserin, a chemical with serotonin and adrenoceptor antagonist activities, increases fish vulnerability to a potential predator threat, when prey fish must deal with this threat based on conspecific chemical alarm cues. For that, I evaluated whether mianserin, diluted in the water, influences the behavioral responses of Nile tilapia (Oreochromis niloticus) to conspecific skin extract (chemical alarm cues). I found that, while mianserin did not abolished antipredator responses, this drug mitigates some components of this defensive reaction. Thus, a potential decrease in serotonin and adrenergic activities reduces the ability of dealing with predators when perceiving conspecific chemical alarm cues.

  11. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  12. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... board while the vessel is being navigated which are protected by a carbon dioxide extinguishing system... when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally... as to sound during the 20-second delay period prior to the discharge of carbon dioxide into the...

  13. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  14. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to persons on board while the vessel is being navigated which are protected by a carbon dioxide... automatically sounded when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and... arranged as to sound during the 20-second delay period prior to the discharge of carbon dioxide into...

  15. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  16. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  17. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... board while the vessel is being navigated which are protected by a carbon dioxide extinguishing system... when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally... as to sound during the 20-second delay period prior to the discharge of carbon dioxide into the...

  18. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to persons on board while the vessel is being navigated which are protected by a carbon dioxide... automatically sounded when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and... arranged as to sound during the 20-second delay period prior to the discharge of carbon dioxide into...

  19. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  20. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... automatically and audibly for at least 20 seconds before carbon dioxide is discharged into the space; (2) Be..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) A protected space must be fitted with...

  1. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reset. (c) For steam boilers, operation of the lower low water cutoff must automatically sound an..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General... periodically unattended machinery space, the auxiliary boiler trip alarm required by 46 CFR 62.35-50, Table...

  2. SAMBA HIV semiquantitative test, a new point-of-care viral-load-monitoring assay for resource-limited settings.

    PubMed

    Ritchie, Allyson V; Ushiro-Lumb, Ines; Edemaga, Daniel; Joshi, Hrishikesh A; De Ruiter, Annemiek; Szumilin, Elisabeth; Jendrulek, Isabelle; McGuire, Megan; Goel, Neha; Sharma, Pia I; Allain, Jean-Pierre; Lee, Helen H

    2014-09-01

    Routine viral-load (VL) testing of HIV-infected individuals on antiretroviral therapy (ART) is used to monitor treatment efficacy. However, due to logistical challenges, implementation of VL has been difficult in resource-limited settings. The aim of this study was to evaluate the performance of the SAMBA semi-Q (simple amplification-based assay semiquantitative test for HIV-1) in London, Malawi, and Uganda. The SAMBA semi-Q can distinguish between patients with VLs above and below 1,000 copies/ml. The SAMBA semi-Q was validated with diluted clinical samples and blinded plasma samples collected from HIV-1-positive individuals. SAMBA semi-Q results were compared with results from the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test, v2.0. Testing of 96 2- to 10-fold dilutions of four samples containing HIV-1 subtype C as well as 488 samples from patients in the United Kingdom, Malawi, and Uganda yielded an overall accuracy for the SAMBA semi-Q of 99% (95% confidence interval [CI], 93.8 to 99.9%) and 96.9% (95% CI 94.9 to 98.3%), respectively, compared to to the Roche test. Analysis of VL data from patients in Malawi and Uganda showed that the SAMBA cutoff of 1,000 copies/ml appropriately distinguished treated from untreated individuals. Furthermore, analysis of the viral loads of 232 patients on ART in Malawi and Uganda revealed similar patterns for virological control, defined as either <1,000 copies/ml (SAMBA cutoff) or <5,000 copies/ml (WHO 2010 criterion; WHO, Antiretroviral Therapy for HIV Infection in Adults and Adolescents: Recommendations for a Public Health Approach, 2010). This study suggests that the SAMBA semi-Q has adequate concurrency with the gold standard measurements for viral load. This test can allow VL monitoring of patients on ART at the point of care in resource-limited settings.

  3. Nuclear power plant alarm systems: Problems and issues

    SciTech Connect

    O'Hara, J.M.; Brown, W.S.

    1991-01-01

    Despite the incorporation of advanced technology into nuclear power plant alarm systems, human factors problems remain. This paper identifies to be addressed in order to allow advanced technology to be used effectively in the design of nuclear power plant alarm systems. The operator's use and processing of alarm system information will be considered. Based upon a review of alarm system research, issues related to general system design, alarm processing, display and control are discussed. It is concluded that the design of effective alarm systems depends on an understanding of the information processing capabilities and limitations of the operator. 39 refs.

  4. Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Paiva, Kleber; Mantelli, Marcia

    2011-01-01

    The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

  5. A Model of Clinical Alarm Errors in Hospital.

    PubMed

    Busch-Vishniac, Ilene

    2015-01-01

    Although there has been much attention paid recently to clinical alarms, research has primarily focused on particular aspects of the clinical alarm problem, such as how to reduce nuisance alarms. This paper takes a broad view of clinical alarms and develops a model of errors in alarm handling and how they affect patients directly. Based on reports in the literature, I estimate that alarms that should sound by current standards do not sound about 9% of the time. Additionally, about 3% of alarms that are clinically significant are ignored, either intentionally or because they were inaudible. However, these errors produce a very low rate of reported alarm-related deaths and other adverse effects (on the order of a couple adverse effects per 10 million alarm errors). While it is not yet possible to estimate the probabilities of clinical alarms having an adverse impact on patients other than the patient whose alarm is sounding, such indirect adverse effects likely occur at a low level as a result of disruption of staff workflow, creation of a noisy hospital environment, and contribution to communication difficulties. Consideration of alarms should include not only the patient connected to the device that is sounding, but also the impact of the alarm on other patients in the vicinity.

  6. 8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), FROM ENTRYWAY, LOOKING NORTH, SHOWING ADDITIONAL 'GAMEWELL' FIRE ALARM SYSTEMS. - Oakland Naval Supply Center, Firehouse, East of Fourth Street, between A & B Streets, Oakland, Alameda County, CA

  7. Alarm guided critical function and success path monitoring

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    The use of alarm indication on the overview (IPSO) display to initiate diagnosis of challenges to critical functions or unavailability of success paths, and further alarm-based guidance toward ultimate diagnosis.

  8. 46 CFR 183.550 - General alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) ELECTRICAL INSTALLATION Miscellaneous Systems and Requirements § 183.550 General alarm systems. All vessels... required by § 184.610 of this chapter may be used to sound the general alarm signal....

  9. Criticality accident alarm system at the Fernald Environmental Management Project

    SciTech Connect

    Marble, R.C.; Brown, T.D.; Wooldridge, J.C.

    1994-12-31

    This paper describes the staus of the Fernald Environmental Management Project (FEMP) criticality alarm system. A new radiation detection alarm system was installed in 1990. The anunciation system, calibration and maintenance, and detector placement is described.

  10. Immuno-epidemiological modeling of HIV-1 predicts high heritability of the set-point virus load, while selection for CTL escape dominates virulence evolution.

    PubMed

    van Dorp, Christiaan H; van Boven, Michiel; de Boer, Rob J

    2014-12-01

    It has been suggested that HIV-1 has evolved its set-point virus load to be optimized for transmission. Previous epidemiological models and studies into the heritability of set-point virus load confirm that this mode of adaptation within the human population is feasible. However, during the many cycles of replication between infection of a host and transmission to the next host, HIV-1 is under selection for escape from immune responses, and not transmission. Here we investigate with computational and mathematical models how these two levels of selection, within-host and between-host, are intertwined. We find that when the rate of immune escape is comparable to what has been observed in patients, immune selection within hosts is dominant over selection for transmission. Surprisingly, we do find high values for set-point virus load heritability, and argue that high heritability estimates can be caused by the 'footprints' left by differing hosts' immune systems on the virus.

  11. 46 CFR 78.47-10 - Manual alarm boxes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Manual alarm boxes. 78.47-10 Section 78.47-10 Shipping... and Emergency Equipment, Etc. § 78.47-10 Manual alarm boxes. (a) In all new installations, manual alarm boxes shall be clearly and permanently marked “IN CASE OF FIRE BREAK GLASS.” Existing boxes not...

  12. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  13. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  14. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  15. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  16. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  17. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  18. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  19. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  20. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  1. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  2. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Manual fire alarm systems. 161.002-12 Section 161.002-12...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-12 Manual fire alarm systems. (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which...

  3. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  4. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  5. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  6. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  7. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  8. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  9. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.201 Sensing and alarm systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms...

  10. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  11. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Alarm and means of escape. (a) Each CO2 system that has a supply of more than 136 kilograms (300 pounds) of CO2, except a system that protects a tank, must have an alarm that sounds for at least 20 seconds before the CO2 is released into the space. (b) Each audible alarm for a CO2 system must have the...

  12. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  13. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  14. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  15. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  16. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Alarm and means of escape. (a) Each CO2 system that has a supply of more than 136 kilograms (300 pounds) of CO2, except a system that protects a tank, must have an alarm that sounds for at least 20 seconds before the CO2 is released into the space. (b) Each audible alarm for a CO2 system must have the...

  17. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Alarm and means of escape. (a) Each CO2 system that has a supply of more than 136 kilograms (300 pounds) of CO2, except a system that protects a tank, must have an alarm that sounds for at least 20 seconds before the CO2 is released into the space. (b) Each audible alarm for a CO2 system must have the...

  18. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... mixture causing actuation of the alarm is taken. (2) If the alarm has a positive displacement mixture pump... centrifugal mixture pump or is not equipped with a mixture pump, the mixture flow rate is reduced to one-half of the alarm's maximum design flow rate. After reduction of pressure or flow rate, the oil content...

  19. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... mixture causing actuation of the alarm is taken. (2) If the alarm has a positive displacement mixture pump... centrifugal mixture pump or is not equipped with a mixture pump, the mixture flow rate is reduced to one-half of the alarm's maximum design flow rate. After reduction of pressure or flow rate, the oil content...

  20. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... mixture causing actuation of the alarm is taken. (2) If the alarm has a positive displacement mixture pump... centrifugal mixture pump or is not equipped with a mixture pump, the mixture flow rate is reduced to one-half of the alarm's maximum design flow rate. After reduction of pressure or flow rate, the oil content...

  1. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  2. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  3. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  4. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  5. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  6. 46 CFR 196.37-7 - General alarm bells.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bells. 196.37-7 Section 196.37-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-7 General alarm bells. (a) All general alarm...

  7. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  8. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  9. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  10. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  11. 46 CFR 119.530 - Bilge high level alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge high level alarms. 119.530 Section 119.530... Bilge and Ballast Systems § 119.530 Bilge high level alarms. (a) Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the...

  12. 46 CFR 76.05-5 - Manual alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Manual alarm system. 76.05-5 Section 76.05-5 Shipping... Fire Detecting and Extinguishing Equipment, Where Required § 76.05-5 Manual alarm system. (a) An approved manual alarm system shall be installed in all areas, other than the main machinery spaces,...

  13. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Manual fire alarm systems. 161.002-12 Section 161.002-12...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-12 Manual fire alarm systems. (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which...

  14. Multiple meter monitoring circuits served by single alarm

    NASA Technical Reports Server (NTRS)

    Bandini, U.

    1967-01-01

    Circuitry for multiple meter relay circuits provides complete isolation for each circuit served by a single alarm and permits alarm reset after an out-of-tolerance event in one relay circuit so that the remaining relay circuits continue to be alarm protected.

  15. Alarm annunciation in a graphical environment

    SciTech Connect

    Adams, D.G.

    1994-08-01

    Well-designed graphical user interfaces, such as Microsoft Windows{trademark} or UNIX{trademark} -- based X-Windows, provide a capability for enhanced display of security alarm information. Conversely, a poorly designed interface can quickly overwhelm an operator. This paper describes types of graphical information that can be displayed and offers guidance on how to best display that information. Limits are proposed for the complexity of the user interface, and guidelines are suggested for the display of maps and sensors.

  16. Smart alarms from medical devices in the OR and ICU.

    PubMed

    Imhoff, Michael; Kuhls, Silvia; Gather, Ursula; Fried, Roland

    2009-03-01

    Alarms in medical devices are a matter of concern in critical and perioperative care. The high rate of false alarms is not only a nuisance for patients and caregivers, but can also compromise patient safety and effectiveness of care. The development of alarm systems has lagged behind the technological advances of medical devices over the last 20 years. From a clinical perspective, major improvements in alarm algorithms are urgently needed. This review gives an overview of the current clinical situation and the underlying problems, and discusses different methods from statistics and computational science and their potential for clinical application. Some examples of the application of new alarm algorithms to clinical data are presented.

  17. LBTO Alarm Notification/Management and Error Diagnostic Tools

    NASA Astrophysics Data System (ADS)

    De La Peña, M. D.; Biddick, C.; Summers, K.; Summers, D.

    2015-09-01

    The Large Binocular Telescope Observatory (LBTO) Telescope Control System (TCS) is comprised of fifteen subsystems and accepts commands from the operator, as well as from six pairs of instruments. To the operator the TCS presents as a high-level set of GUIs with each GUI corresponding to one specific subsystem and providing full state information and varying degrees of control. The TCS GUIs not only provide the operators with broad control over all aspects of the telescope, but each individual GUI also reports problems within its domain through the use of color-coded messages and widgets indicating the seriousness of the issue. While there is significant problem reporting available to the operator, until recently there was no centralized and persistent visual indication or “annunciator” display for issues. In order to provide a way to present problems in a centralized and persistent fashion with “on-the-spot guidance” to ease the job of the operator and to have an acknowledge capability, the LBTO project decided to leverage an existing Alarm Handler which is a GUI client application associated with the Experimental Physics and Industrial Control System (EPICS)1. This paper briefly describes the TCS sources of problem reporting information and how the EPICS Alarm Handler supplements the current system.

  18. Las Matematicas: Lenguaje Universal. Grados Intermedios, Nivel 5a: Geometria - Conjuntos de Puntos (Mathematics: A Universal Language. Intermediate Grades, Level 5a: Geometry - Sets of Points).

    ERIC Educational Resources Information Center

    Dissemination and Assessment Center for Bilingual Education, Austin, TX.

    This is one of a series of student booklets designed for use in a bilingual mathematics program in grades 6-8. The general format is to present each page in both Spanish and English. The mathematical topics in the booklet include points, lines, planes, space, angles, and intersection and union of sets. (MK)

  19. A Case Example of the Implementation of Schoolwide Positive Behavior Support in a High School Setting Using Change Point Test Analysis

    ERIC Educational Resources Information Center

    Bohanon, Hank; Fenning, Pamela; Hicks, Kira; Weber, Stacey; Thier, Kimberly; Aikins, Brigit; Morrissey, Kelly; Briggs, Alissa; Bartucci, Gina; McArdle, Lauren; Hoeper, Lisa; Irvin, Larry

    2012-01-01

    The purpose of this case study was to expand the literature base regarding the application of high school schoolwide positive behavior support in an urban setting for practitioners and policymakers to address behavior issues. In addition, the study describes the use of the Change Point Test as a method for analyzing time series data that are…

  20. Public Data Set: Erratum: "Multi-point, high-speed passive ion velocity distribution diagnostic on the Pegasus Toroidal Experiment" [Rev. Sci. Instrum. 83, 10D516 (2012)

    SciTech Connect

    Burke, Marcus G.; Fonck, Raymond J.; Bongard, Michael W.; Schlossberg, David J.; Winz, Gregory R.

    2016-07-18

    This data set contains openly-documented, machine readable digital research data corresponding to figures published in M.G. Burke et al., 'Erratum: "Multi-point, high-speed passive ion velocity distribution diagnostic on the Pegasus Toroidal Experiment" [Rev. Sci. Instrum. 83, 10D516 (2012)],' Rev. Sci. Instrum. 87, 079902 (2016).

  1. Estimation of influential points in any data set from coefficient of determination and its leave-one-out cross-validated counterpart.

    PubMed

    Tóth, Gergely; Bodai, Zsolt; Héberger, Károly

    2013-10-01

    Coefficient of determination (R (2)) and its leave-one-out cross-validated analogue (denoted by Q (2) or R cv (2) ) are the most frequantly published values to characterize the predictive performance of models. In this article we use R (2) and Q (2) in a reversed aspect to determine uncommon points, i.e. influential points in any data sets. The term (1 - Q (2))/(1 - R (2)) corresponds to the ratio of predictive residual sum of squares and the residual sum of squares. The ratio correlates to the number of influential points in experimental and random data sets. We propose an (approximate) F test on (1 - Q (2))/(1 - R (2)) term to quickly pre-estimate the presence of influential points in training sets of models. The test is founded upon the routinely calculated Q (2) and R (2) values and warns the model builders to verify the training set, to perform influence analysis or even to change to robust modeling.

  2. Specification of business rules for the development of hospital alarm system: application to the pharmaceutical validation.

    PubMed

    Boussadi, Abdelali; Bousquet, Cedric; Sabatier, Brigitte; Colombet, Isabelle; Degoulet, Patrice

    2008-01-01

    Although clinical alarm systems are part of the knowledge management setting within healthcare organisations, modelling of business processes related to decision support and knowledge representation of decision rules are seldom described. We propose a customization of the Unified Process that takes into account user requirements for clinical alarm systems by introducing the Semantics of Business Vocabulary and Business Rules (SBVR). This methodology was applied to the design and implementation of a clinical alarm system for pharmaceutical validation at the European Hospital Georges Pompidou (HEGP). Rules were implemented using the IlogJRules Business Rule Management System. We produced 3 business rules patterns and 427 instances of rules. As SBVR is close to natural language, pharmacists were able to understand rules and participate to their design.

  3. On Alarm Protocol in Wireless Sensor Networks

    NASA Astrophysics Data System (ADS)

    Cichoń, Jacek; Kapelko, Rafał; Lemiesz, Jakub; Zawada, Marcin

    We consider the problem of efficient alarm protocol for ad-hoc radio networks consisting of devices that try to gain access for transmission through a shared radio communication channel. The problem arise in tasks that sensors have to quickly inform the target user about an alert situation such as presence of fire, dangerous radiation, seismic vibrations, and more. In this paper, we present a protocol which uses O(logn) time slots and show that Ω(logn/loglogn) is a lower bound for used time slots.

  4. Density functional theory calculations of the lowest energy quintet and triplet states of model hemes: role of functional, basis set, and zero-point energy corrections.

    PubMed

    Khvostichenko, Daria; Choi, Andrew; Boulatov, Roman

    2008-04-24

    We investigated the effect of several computational variables, including the choice of the basis set, application of symmetry constraints, and zero-point energy (ZPE) corrections, on the structural parameters and predicted ground electronic state of model 5-coordinate hemes (iron(II) porphines axially coordinated by a single imidazole or 2-methylimidazole). We studied the performance of B3LYP and B3PW91 with eight Pople-style basis sets (up to 6-311+G*) and B97-1, OLYP, and TPSS functionals with 6-31G and 6-31G* basis sets. Only hybrid functionals B3LYP, B3PW91, and B97-1 reproduced the quintet ground state of the model hemes. With a given functional, the choice of the basis set caused up to 2.7 kcal/mol variation of the quintet-triplet electronic energy gap (DeltaEel), in several cases, resulting in the inversion of the sign of DeltaEel. Single-point energy calculations with triple-zeta basis sets of the Pople (up to 6-311G++(2d,2p)), Ahlrichs (TZVP and TZVPP), and Dunning (cc-pVTZ) families showed the same trend. The zero-point energy of the quintet state was approximately 1 kcal/mol lower than that of the triplet, and accounting for ZPE corrections was crucial for establishing the ground state if the electronic energy of the triplet state was approximately 1 kcal/mol less than that of the quintet. Within a given model chemistry, effects of symmetry constraints and of a "tense" structure of the iron porphine fragment coordinated to 2-methylimidazole on DeltaEel were limited to 0.3 kcal/mol. For both model hemes the best agreement with crystallographic structural data was achieved with small 6-31G and 6-31G* basis sets. Deviation of the computed frequency of the Fe-Im stretching mode from the experimental value with the basis set decreased in the order: nonaugmented basis sets, basis sets with polarization functions, and basis sets with polarization and diffuse functions. Contraction of Pople-style basis sets (double-zeta or triple-zeta) affected the results

  5. A hybrid approach to the fusion of partially coinciding alarms from asynchronous or specialized detectors

    NASA Astrophysics Data System (ADS)

    Smock, Brandon; Wilson, Joseph; Glenn, Taylor

    2014-06-01

    The accurate detection of a diverse set of targets often requires the use of multiple sensor modalities and algorithms. Fusion approaches can be used to combine information from multiple sensors or detectors. But typical fusion approaches are not suitable when detectors do not operate on all of the same locations of interest, or when detectors are specialized to detect disjoint sets of target types. Run Packing is an algorithm we developed previously to optimally combine detectors when their output never coincides, which can be expected when the detectors are specialized to detect different target types. But when asynchronous detectors sometimes coincide, or specialized detectors sometimes detect the same target, Run Packing ignores this coincidence information and thus may be suboptimal in certain cases. In this paper, we show how multi-detector fusion involving partially­ coinciding alarms can be re-framed as an equivalent fusion problem that is optimally addressed by Run Packing. This amounts to a hierarchical or hybrid approach involving fusion methods to join coinciding alarms at the same location into a single unified alarm and then using Run Packing to optimally fuse the resulting set of non­ coinciding alarms. We report preliminary results of applying the method in a few typical landmine detection scenarios to demonstrate its potential utility.

  6. A novel connectionist framework for computation of an approximate convex-hull of a set of planar points, circles and ellipses.

    PubMed

    Pal, Srimanta; Bhattacharya, Sabyasachi; Pal, Nikhil R

    2006-02-01

    We propose a two layer neural network for computation of an approximate convex-hull of a set of points or a set of circles/ellipses of different sizes. The algorithm is based on a very elegant concept - shrinking of a rubber band surrounding the set of planar objects. Logically, a set of neurons is placed on a circle (rubber band) surrounding the objects. Each neuron has a parameter vector associated with it. This may be viewed as the current position of the neuron. The given set of points/objects exerts a force of attraction on every neuron, which determines how its current position will be updated (as if, the force determines the direction of movement of the neuron lying on the rubber band). As the network evolves, the neurons (parameter vectors) approximate the convex-hull more and more accurately. The scheme can be applied to find the convex-hull of a planar set of circles or ellipses or a mixture of the two. Some properties related to the evolution of the algorithm are also presented.

  7. Alarm handler for the advanced photon source control system

    SciTech Connect

    Kraimer, M.R.; Cha, B.K.; Anderson, M.

    1991-01-01

    The Advanced Photon Source (APS), now under construction at Argonne National Laboratory, will have a control system employing graphics workstations at the operator interface level and VME-based microprocessors operating with a distributed database at the field level. The alarm handler is an application utilizing X-Windows running on one or more operator interface workstations which monitors alarms generated by the VME-based microprocessors. Alarms can be grouped in a hierarchical manner. The operator can monitor, acknowledge, and mask alarms either individually or aggregately. Alarm changes of state and all operator modifications are logged. When alarms occur, display windows are automatically generated conveying system and subsystem relationships and severity. Menus are used to modify the alarm action configuration files and to obtain help. Since alarm groups are defined via an alarm configuration file, the alarm handler is a general purpose application which can be customized to monitor a single subsystem or configured to monitor the entire accelerator complex. 2 refs., 2 figs.

  8. Development of net cage acoustic alarm system

    NASA Astrophysics Data System (ADS)

    Hong, Shih-Wei; Wei, Ruey-Chang

    2001-05-01

    In recent years, the fishery production has been drastically decreased in Taiwan, mainly due to overfishing and coast pollution; therefore, fishermen and corporations are encouraged by government to invest in ocean net cage aquaculture. However, the high-price fishes in the net cage are often coveted, so incidences of fish stealing and net cage breaking were found occasionally, which cause great economical loss. Security guards or a visual monitoring system has limited effect, especially in the night when these intrusions occur. This study is based on acoustic measure to build a net cage alarm system, which includes the sonobuoy and monitor station on land. The sonobuoy is a passive sonar that collects the sounds near the net cage and transmits the suspected signal to the monitor station. The signals are analyzed by the control program on the personal computer in the monitor station, and the alarms at different stages could be activated by the sound levels and durations of the analyzed data. To insure long hours of surveillance, a solar panel is applied to charge the battery, and a photodetector is used to activate the system.

  9. Alarm system for a nuclear control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  10. False alarm reduction during landmine detection

    NASA Astrophysics Data System (ADS)

    Prado, P. J.; Chongpison, A.; Doraisamy, L.

    2007-04-01

    Quadrupole Resonance sensors have the unique capability of detecting explosives from buried, plastic-cased antipersonnel and antitank landmines. The chemical specificity of this radio-frequency technique provides the potential to deliver remarkably low false alarm rates during landmine detection. This is of particular importance to deminers, who frequently come across numerous clutter items before uncovering a mine. Quadrupole Resonance is typically utilized in a confirmation mode; preceded by rapid primary scans carried out by, for example, metal detectors, ground penetrating radars or a fusion of these. Significant technical and scientific advances have resulted in the fabrication of handheld and vehicle mounted Quadrupole Resonance landmine detectors in compact, power-efficient configurations. The development work is focused on baseline sensitivity increase, as well as the achievement of high detection performance under field conditions. The mine detection capability of Quadrupole Resonance detectors has been evaluated during various blind tests. A modular handheld unit, combining primary and confirmation sensors, was designed to be operated by a single person. A series of field tests demonstrate the unique capability of Quadrupole Resonance for significant false alarm reduction.

  11. Opposite responses by different chemoreceptors set a tunable preference point in Escherichia coli pH taxis.

    PubMed

    Yang, Yiling; Sourjik, Victor

    2012-12-01

    In bacterial habitats, the ability to follow spatial gradients of environmental factors that affect growth and survival can be largely advantageous. The bacterial strategy for unidirectional chemotactic movement in gradients of typical attractants or repellents, such as nutrients or toxins, is well understood. Optimal levels of other factors, however, may be found at intermediate points of a gradient and thus require a bidirectional tactic movement towards the optimum. Here we investigate the chemotactic response of Escherichia coli to pH as an example of such bidirectional taxis. We confirm that E. coli uses chemotaxis to avoid both extremes of low and high pH and demonstrate that the sign of the response is inverted from base-seeking to acid-seeking at a well-defined value of pH. Such inversion is enabled by opposing pH sensing by the two major chemoreceptors, Tar and Tsr, such that the relative strength of the response is modulated by adaptive receptor methylation. We further demonstrate that the inversion point of the pH response can be adjusted in response to changes in the cell density.

  12. Jena Reference Air Set (JRAS): a multi-point scale anchor for isotope measurements of CO2 in air

    NASA Astrophysics Data System (ADS)

    Wendeberg, M.; Richter, J. M.; Rothe, M.; Brand, W. A.

    2013-03-01

    The need for a unifying scale anchor for isotopes of CO2 in air was brought to light at the 11th WMO/IAEA Meeting of Experts on Carbon Dioxide in Tokyo 2001. During discussions about persistent discrepancies in isotope measurements between the worlds leading laboratories, it was concluded that a unifying scale anchor for Vienna Pee Dee Belemnite (VPDB) of CO2 in air was desperately needed. Ten years later, at the 2011 Meeting of Experts on Carbon Dioxide in Wellington, it was recommended that the Jena Reference Air Set (JRAS) become the official scale anchor for isotope measurements of CO2 in air (Brailsford, 2012). The source of CO2 used for JRAS is two calcites. After releasing CO2 by reaction with phosphoric acid, the gases are mixed into CO2-free air. This procedure ensures both isotopic stability and longevity of the CO2. That the reference CO2 is generated from calcites and supplied as an air mixture is unique to JRAS. This is made to ensure that any measurement bias arising from the extraction procedure is eliminated. As every laboratory has its own procedure for extracting the CO2, this is of paramount importance if the local scales are to be unified with a common anchor. For a period of four years, JRAS has been evaluated through the IMECC1 program, which made it possible to distribute sets of JRAS gases to 13 laboratories worldwide. A summary of data from the six laboratories that have reported the full set of results is given here along with a description of the production and maintenance of the JRAS scale anchors. 1 IMECC refers to the EU project "Infrastructure for Measurements of the European Carbon Cycle" (http://imecc.ipsl.jussieu.fr/).

  13. Recurrent hamstring muscle injury: applying the limited evidence in the professional football setting with a seven-point programme

    PubMed Central

    Brukner, Peter; Nealon, Andrew; Morgan, Christopher; Burgess, Darren; Dunn, Andrew

    2014-01-01

    Recurrent hamstring injuries are a major problem in sports such as football. The aim of this paper was to use a clinical example to describe a treatment strategy for the management of recurrent hamstring injuries and examine the evidence for each intervention. A professional footballer sustained five hamstring injuries in a relatively short period of time. The injury was managed successfully with a seven-point programme—biomechanical assessment and correction, neurodynamics, core stability, eccentric strengthening, an overload running programme, injection therapies and stretching/relaxation. The evidence for each of these treatment options is reviewed. It is impossible to be definite about which aspects of the programme contributed to a successful outcome. Only limited evidence is available in most cases; therefore, decisions regarding the use of different treatment modalities must be made by using a combination of clinical experience and research evidence. PMID:23322894

  14. An investigation of training strategies to improve alarm reactions.

    PubMed

    Bliss, James P; Chancey, Eric T

    2014-09-01

    Researchers have suggested that operator training may improve operator reactions; however, researchers have not documented this for alarm reactions. The goal of this research was to train participants to react to alarms using sensor activity patterns. In Experiment 1, 80 undergraduates monitored a simulated security screen while completing a primary word search task. They received spatial, temporal, single sensor, or no training to respond to alarms of differing reliability levels. Analyses revealed more appropriate and quicker reactions when participants were trained and when the alarms were reliable. In Experiment 2, 56 participants practiced time estimation by simple repetition, performance feedback, or performance feedback and temporal subdivision. They then reacted to alarms based on elapsed time between sensor activity and alarm onset. Surprisingly, results indicated that participants did not benefit differentially from temporal interval training, focusing instead on advertised system reliability. Researchers should replicate these findings with realistic tasks and real-world complex task operators.

  15. Classification of alarm processing techniques and human performance issues

    SciTech Connect

    Kim, I.S.; O`Hara, J.M.

    1993-05-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance.

  16. Classification of alarm processing techniques and human performance issues

    SciTech Connect

    Kim, I.S.; O'Hara, J.M.

    1993-01-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance.

  17. The alarm system and a possible way forward.

    PubMed

    Alm, Håkan; Osvalder, Anna-Lisa

    2012-01-01

    The aim of this paper is to make a review of studies concerning problems with alarm systems and to make a theoretical analysis of these problems. The aim is also to show some general design ideas to improve alarm presentation in process descriptions. Using research results from situation awareness and decision making a number of suggestions for further development of alarm systems are presented. Recommendations include providing operators of complex systems feedback that can support their mental models and situational awareness. Furthermore a recommendation is to design alarm systems that can learn from experience.

  18. Medical History of Elderly Patients in the Emergency Setting: Not an Easy Point-of-Care Diagnostic Marker.

    PubMed

    Lindner, Tobias; Slagman, Anna; Senkin, Arthur; Möckel, Martin; Searle, Julia

    2015-01-01

    Background. Medical histories are a crucially important diagnostic tool. Elderly patients represent a large and increasing group of emergency patients. Due to cognitive deficits, taking a reliable medical history in this patient group can be difficult. We sought to evaluate the medical history-taking in emergency patients above 75 years of age with respect to duration and completeness. Methods. Anonymous data of consecutive patients were recorded. Times for the defined basic medical history-taking were documented, as were the availability of other sources and times to assess these. Results. Data of 104 patients were included in the analysis. In a quarter of patients (25%, n = 26) no complete basic medical history could be obtained. In the group of patients where complete data could be gathered, only 16 patients were able to provide all necessary information on their own. Including other sources like relatives or GPs prolonged the time until complete medical history from 7.3 minutes (patient only) to 26.4 (+relatives) and 56.3 (+GP) minutes. Conclusions. Medical histories are important diagnostic tools in the emergency setting and are prolonged in the elderly, especially if additional documentation and third parties need to be involved. New technologies like emergency medical cards might help to improve the availability of important patient data but implementation of these technologies is costly and faces data protection issues.

  19. [The alarming increase of incapacity for work].

    PubMed

    Thibaut, P

    2013-09-01

    The alarming increase of incapacity for work The increase of incapacity for work in Belgium and in Europe is not a new phenomenon but only the transposition of an experience already lived on others continents (Canada--USA). The bio-psycho-social model proves to be, on the international level, as the more efficient view for the understanding of the mechanisms production of the disability and therefore of the incapacity for work. Following this approach, the chronic pain is the result of the dynamic interaction between physiological, psychological and social factors. It mentions also an existing link between the pain and the depression itself being a determining factor in the persistence of the incapacity for work. The bio-psycho-social model can only be conceived in the interdisciplinary approach, and will for sure allow to optimize the support and the use of medicines with a painkiller and depressive aim. The socio-economic impact created represents actually a real health problem.

  20. Using integrated bio-physiotherapy informatics in home health-care settings: A qualitative analysis of a point-of-care decision support system.

    PubMed

    Canally, Culum; Doherty, Sean; Doran, Diane M; Goubran, Rafik A

    2015-06-01

    The growing need to gain efficiencies within a home care setting has prompted home care practitioners to focus on health informatics to address the needs of an aging clientele. The remote and heterogeneous nature of the home care environment necessitates the use of non-intrusive client monitoring and a portable, point-of-care graphical user interface. Using a grounded theory approach, this article examines the simulated use of a graphical user interface by practitioners in a home care setting to explore the salient features of monitoring the activity of home care clients. The results demonstrate the need for simple, interactive displays that can provide large amounts of geographical and temporal data relating to patient activity. Additional emerging themes from interviews indicate that home care professionals would use a graphical user interface of this type for patient education and goal setting as well as to assist in the decision-making process of home care practitioners.

  1. The chemistry of eavesdropping, alarm, and deceit.

    PubMed Central

    Stowe, M K; Turlings, T C; Loughrin, J H; Lewis, W J; Tumlinson, J H

    1995-01-01

    Arthropods that prey on or parasitize other arthropods frequently employ those chemical cues that reliably indicate the presence of their prey or hosts. Eavesdropping on the sex pheromone signals emitted to attract mates allows many predators and parasitoids to find and attack adult insects. The sex pheromones are also useful signals for egg parasitoids since eggs are frequently deposited on nearby plants soon after mating. When the larval stages of insects or other arthropods are the targets, a different foraging strategy is employed. The larvae are often chemically inconspicuous, but when they feed on plants the injured plants respond by producing and releasing defensive chemicals. These plant chemicals may also serve as "alarm signals" that are exploited by predators and parasitoids to locate their victims. There is considerable evidence that the volatile "alarm signals" are induced by interactions of substances from the herbivore with the damaged plant tissue. A very different strategy is employed by several groups of spiders that remain stationary and send out chemical signals that attract prey. Some of these spiders prey exclusively on male moths. They attract the males by emitting chemicals identical to the sex pheromones emitted by female moths. These few examples indicate the diversity of foraging strategies of arthropod predators and parasitoids. It is likely that many other interesting chemically mediated interactions between arthropod hunters and their victims remain to be discovered. Increased understanding of these systems will enable us to capitalize on natural interactions to develop more ecologically sound, environmentally safe methods for biological control of insect pests of agriculture. PMID:7816823

  2. Transformation of ground vibration signal for debris-flow monitoring and detection in alarm systems.

    PubMed

    Abancó, Clàudia; Hürlimann, Marcel; Fritschi, Bruno; Graf, Christoph; Moya, José

    2012-01-01

    Debris flows are fast mass movements formed by a mix of water and solid materials, which occur in steep torrents, and are a source of high risks for human settlements. Geophones are widely used to detect the ground vibration induced by passing debris flows. However, the recording of geophone signals usually requires storing a huge amount of data, which leads to problems in storage capacity and power consumption. This paper presents a method to transform and simplify the signals measured by geophones. The key input parameter is the ground velocity threshold, which removes the seismic noise that is not related to debris flows. A signal conditioner was developed to implement the transformation and the ground velocity threshold was set by electrical resistors. The signal conditioner was installed at various European monitoring sites to test the method. Results show that data amount and power consumption can be greatly reduced without losing much information on the main features of the debris flows. However, the outcome stresses the importance of choosing a ground vibration threshold, which must be accurately calibrated. The transformation is also suitable to detect other rapid mass movements and to distinguish among different processes, which points to a possible implementation in alarm systems.

  3. Transformation of Ground Vibration Signal for Debris-Flow Monitoring and Detection in Alarm Systems

    PubMed Central

    Abancó, Clàudia; Hürlimann, Marcel; Fritschi, Bruno; Graf, Christoph; Moya, José

    2012-01-01

    Debris flows are fast mass movements formed by a mix of water and solid materials, which occur in steep torrents, and are a source of high risks for human settlements. Geophones are widely used to detect the ground vibration induced by passing debris flows. However, the recording of geophone signals usually requires storing a huge amount of data, which leads to problems in storage capacity and power consumption. This paper presents a method to transform and simplify the signals measured by geophones. The key input parameter is the ground velocity threshold, which removes the seismic noise that is not related to debris flows. A signal conditioner was developed to implement the transformation and the ground velocity threshold was set by electrical resistors. The signal conditioner was installed at various European monitoring sites to test the method. Results show that data amount and power consumption can be greatly reduced without losing much information on the main features of the debris flows. However, the outcome stresses the importance of choosing a ground vibration threshold, which must be accurately calibrated. The transformation is also suitable to detect other rapid mass movements and to distinguish among different processes, which points to a possible implementation in alarm systems. PMID:22666064

  4. The response of the temperature of cold-point mesopause to solar activity based on SABER data set

    NASA Astrophysics Data System (ADS)

    Tang, Chaoli; Liu, Dong; Wei, Heli; Wang, Yingjian; Dai, Congming; Wu, Pengfei; Zhu, Wenyue; Rao, Ruizhong

    2016-07-01

    The thermal structure and energy balance of upper atmosphere are dominated by solar activity. The response of cold-point mesopause (CPM) to solar activity is an important form. This article presents the response of the temperature of CPM (T-CPM) to solar activity using 14 year Sounding of the Atmosphere using Broadband Emission Radiometry data series over 80°S-80°N regions. These regions are divided into 16 latitude zones with 10° interval, and the spatial areas of 80°S-80°N, 180°W-180°E are divided into 96 lattices with 10°(latitude) × 60°(longitude) grid. The annual-mean values of T-CPM and F10.7 are calculated. The least squares regression method and correlation analysis are applied to these annual-mean series. First, the results show that the global T-CPM is significantly correlated to solar activity at the 0.05 level of significance with correlation coefficient of 0.90. The global solar response of T-CPM is 4.89 ± 0.67 K/100 solar flux unit. Then, for each latitude zone, the solar response of T-CPM and its fluctuation are obtained. The solar response of T-CPM becomes stronger with increasing latitude. The fluctuation ranges of solar response at middle-latitude regions are smaller than those of the equator and high-latitude regions, and the global distribution takes on W shape. The corelationship analysis shows that the T-CPM is significantly correlated to solar activity at the 0.05 level of significance for each latitude zone. The correlation coefficients at middle-latitude regions are higher than those of the equator and high-latitude regions, and the global distribution takes on M shape. At last, for each grid cell, the response of T-CPM to solar activity and their correlation coefficient are presented.

  5. An Approach to Alleviate the False Alarm in Building Change Detection from Urban Vhr Image

    NASA Astrophysics Data System (ADS)

    Chen, J.; Hou, J. L.; Deng, M.

    2016-06-01

    Building change detection from very-high-resolution (VHR) urban remote sensing image frequently encounter the challenge of serious false alarm caused by different illumination or viewing angles in bi-temporal images. An approach to alleviate the false alarm in urban building change detection is proposed in this paper. Firstly, as shadows casted by urban buildings are of distinct spectral and shape feature, it adopts a supervised object-based classification technique to extract them in this paper. Secondly, on the opposite direction of sunlight illumination, a straight line is drawn along the principal orientation of building in every extracted shadow region. Starting from the straight line and moving toward the sunlight direction, a rectangular area is constructed to cover partial shadow and rooftop of each building. Thirdly, an algebra and geometry invariant based method is used to abstract the spatial topological relationship of the potential unchanged buildings from all central points of the rectangular area. Finally, based on an oriented texture curvature descriptor, an index is established to determine the actual false alarm in building change detection result. The experiment results validate that the proposed method can be used as an effective framework to alleviate the false alarm in building change detection from urban VHR image.

  6. Evidence from catch-up growth and hoarding behavior of rats that exposure to hypobaric air lowers the body-mass set point.

    PubMed

    Bozzini, Carlos E; Lezón, Christian E; Norese, María F; Conti, María I; Martínez, María P; Olivera, María I; Alippi, Rosa M

    2005-01-01

    The depression of body growth rate and the reduction of body mass for chronological age and gender in growing experimental animals exposed to hypobaric air (simulated high altitude = SHA) have been associated with hypophagia because of reduced appetite. Catch-up growth during protein recovery after a short period of protein restriction only occurs if food intake becomes super-normal, which should not be possible under hypoxic conditions if the set-point for appetite is adjusted by the level of SHA. The present investigation was designed to test the hypothesis that growth retardation during exposure to SHA is due to an alteration of the neural mechanism for setting body mass size rather than a primary alteration of the central set-point for appetite. One group of female rats aged 35 d were exposed to SHA (5460m) in a SHA chamber for 27 d (HX rats). Other group was maintained under local barometric pressure conditions (NX rats). One half of both NX and HX rats were fed a protein-free diet for the initial 9 d of the experimental period. From this time on, they were fed a diet containing 20% protein, as were the remaining rats of both groups during the entire experimental period. The growth rates of both mass and length of the body were significantly depressed in well-nourished rats exposed to SHA during the entire observation period when compared to normoxic ones. At its end, body mass and body length were 24% and 21% less in HX than in NX rats. Growth rates were negatively affected by protein restriction in both NX and HX rats. During protein recovery, they reached supernormal values in response to supernormal levels of energy intake that allowed a complete catch-up of both body mass and length. The finding that energy intake during the period of protein rehabilitation in HX rats previously stunted by protein restriction was markedly higher than in HX control ones at equal levels of hypoxia demonstrates that the degree of hypoxia does not determine directly the

  7. [Citalopram, escitalopram and prolonged QT: warning or alarm?].

    PubMed

    Alvarez, Enric; Vieira, Sara; Garcia-Moll, Xavier

    2014-01-01

    The alerts issued by regulatory agencies on the potential cardiac toxicity of citalopram and escitalopram have caused alarm among clinicians. A review of the data concerning this topic shows that the alarm should be limited to patients with a history of syncope or poisoning. As a precautionary measure, an electrocardiogram should be performed on elderly patients.

  8. 46 CFR 154.1842 - Cargo system: Controls and alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Cargo system: Controls and alarms. 154.1842 Section 154.1842 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... system: Controls and alarms. The master shall ensure that the cargo emergency shut-down system and...

  9. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  10. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  11. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  12. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  13. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  14. Successful Use of the Nocturnal Urine Alarm for Diurnal Enuresis.

    ERIC Educational Resources Information Center

    Friman, Patrick C.; Vollmer, Dennis

    1995-01-01

    A urine alarm, typically used to treat nocturnal enuresis, was effectively used to treat diurnal enuresis in a 15-year-old female with depression, attention deficit hyperactivity disorder, and conduct disorder. The study indicated that the alarm eliminated wetting in both treatment phases and that continence was maintained at three-month and…

  15. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  16. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  17. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  18. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... alarm signaling systems used for alerting employees regardless of the other functions of the system. (3... 29 Labor 5 2011-07-01 2011-07-01 false Employee alarm systems. 1910.165 Section 1910.165 Labor... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Fire Protection Other Fire Protection Systems § 1910.165...

  19. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  20. 46 CFR 154.1842 - Cargo system: Controls and alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo system: Controls and alarms. 154.1842 Section 154... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1842 Cargo system: Controls and alarms. The master shall ensure that the cargo emergency shut-down system and...

  1. 33 CFR 401.17 - Pitch indicators and alarms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Pitch indicators and alarms. 401... indicators and alarms. Every vessel of 1600 gross registered tons or integrated tug and barge or articulated... propeller shall be equipped with— (a) A pitch indicator in the wheelhouse and the engine room; and...

  2. 33 CFR 157.440 - Autopilot alarm or indicator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Autopilot alarm or indicator. 157.440 Section 157.440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... § 157.440 Autopilot alarm or indicator. (a) A tankship owner or operator shall ensure that...

  3. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  4. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  5. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  6. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  7. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  8. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  9. 46 CFR 182.530 - Bilge high level alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Bilge high level alarms. 182.530 Section 182.530... TONS) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.530 Bilge high level alarms. (a) On a... operating station to indicate a high water level in each of the following normally unmanned spaces: (1)...

  10. 33 CFR 157.440 - Autopilot alarm or indicator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Autopilot alarm or indicator. 157.440 Section 157.440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... § 157.440 Autopilot alarm or indicator. (a) A tankship owner or operator shall ensure that...

  11. 33 CFR 401.17 - Pitch indicators and alarms.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Pitch indicators and alarms. 401... indicators and alarms. Every vessel of 1600 gross registered tons or integrated tug and barge or articulated... propeller shall be equipped with— (a) A pitch indicator in the wheelhouse and the engine room; and...

  12. 1. Photographic copy of fire alarm plan for Control and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of fire alarm plan for Control and Recording Center Building 4221/E-22, showing layout of rooms. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Edwards Test Station, Fire Alarm Plan, Bldg. E-22,' drawing no. EFA/11-1, December 15, 1961. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA

  13. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  14. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  15. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  16. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  17. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  18. 46 CFR 183.550 - General alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false General alarm systems. 183.550 Section 183.550 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Miscellaneous Systems and Requirements § 183.550 General alarm systems. All...

  19. Sensor fusion methods for reducing false alarms in heart rate monitoring.

    PubMed

    Borges, Gabriel; Brusamarello, Valner

    2016-12-01

    Automatic patient monitoring is an essential resource in hospitals for good health care management. While alarms caused by abnormal physiological conditions are important for the delivery of fast treatment, they can be also a source of unnecessary noise because of false alarms caused by electromagnetic interference or motion artifacts. One significant source of false alarms is related to heart rate, which is triggered when the heart rhythm of the patient is too fast or too slow. In this work, the fusion of different physiological sensors is explored in order to create a robust heart rate estimation. A set of algorithms using heart rate variability index, Bayesian inference, neural networks, fuzzy logic and majority voting is proposed to fuse the information from the electrocardiogram, arterial blood pressure and photoplethysmogram. Three kinds of information are extracted from each source, namely, heart rate variability, the heart rate difference between sensors and the spectral analysis of low and high noise of each sensor. This information is used as input to the algorithms. Twenty recordings selected from the MIMIC database were used to validate the system. The results showed that neural networks fusion had the best false alarm reduction of 92.5 %, while the Bayesian technique had a reduction of 84.3 %, fuzzy logic 80.6 %, majority voter 72.5 % and the heart rate variability index 67.5 %. Therefore, the proposed algorithms showed good performance and could be useful in bedside monitors.

  20. A correlation consistency based multivariate alarm thresholds optimization approach.

    PubMed

    Gao, Huihui; Liu, Feifei; Zhu, Qunxiong

    2016-11-01

    Different alarm thresholds could generate different alarm data, resulting in different correlations. A new multivariate alarm thresholds optimization methodology based on the correlation consistency between process data and alarm data is proposed in this paper. The interpretative structural modeling is adopted to select the key variables. For the key variables, the correlation coefficients of process data are calculated by the Pearson correlation analysis, while the correlation coefficients of alarm data are calculated by kernel density estimation. To ensure the correlation consistency, the objective function is established as the sum of the absolute differences between these two types of correlations. The optimal thresholds are obtained using particle swarm optimization algorithm. Case study of Tennessee Eastman process is given to demonstrate the effectiveness of proposed method.

  1. Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

    SciTech Connect

    Zakariaee, R; Brown, C J; Hamarneh, G; Parsons, C A; Spadinger, I

    2014-08-15

    Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

  2. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Location and spacing of manual alarm boxes. 76.35-10... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in...

  3. Carbon dioxide analysers: accuracy, alarm limits and effects of interfering gases.

    PubMed

    Lauber, R; Seeberger, B; Zbinden, A M

    1995-07-01

    Six mainstream and twelve sidestream infrared carbon dioxide (CO2) analysers were tested for accuracy of the CO2 display value, alarm activation and the effects of nitrous oxide (N2O), oxygen (O2) and water vapour according to the ISO Draft International Standard (DIS)#9918. Mainstream analysers (M-type): Novametrix Capnogard 1265; Hewlett Packard HP M1166A (CO2-module HP M1016A); Datascope Passport; Marquette Tramscope 12; Nellcor Ultra Cap N-6000; Hellige Vicom-sm SMU 611/612 ETC. Sidestream analysers: Brüel & Kjaer Type 1304; Datex Capnomac II; Marquette MGA-AS; Datascope Multinex; Ohmeda 4700 OxiCap (all type S1: respiratory cycles not demanded); Biochem BCI 9000; Bruker BCI 9100; Dräger Capnodig and PM 8020; Criticare Poet II; Hellige Vicom-sm SMU 611/612 A-GAS (all type S2: respiratory cycles demanded). The investigations were performed with premixed test gases (2.5, 5, 10 vol%, error < or = 1% rel.). Humidification (37 degrees C) of gases were generated by a Dräger Aquapor. Respiratory cycles were simulated by manually activated valves. All monitors complied with the tolerated accuracy bias in CO2 reading (< or = 12% or 4 mmHg of actual test gas value) for wet and dry test gases at all concentrations, except that the Marquette MGA-AS exceeded this accuracy limit with wet gases at 5 and 10 vol% CO2. Water condensed in the metal airway adapter of the HP M1166A at 37 degrees C gas temperature but not at 30 degrees C. The Servomex 2500 (nonclinical reference monitor), Passport (M-type), Multinex (S1-type) and Poet II (S2-type) showed the least bias for dry and wet gases. Nitrous oxide and O2 had practically no effect on the Capnodig and the errors in the others were max. 3.4 mmHg, still within the tolerated bias in the DIS (same as above). The difference between the display reading at alarm activation and the set point was in all monitors (except in the Capnodig: bias 1.75 mmHg at 5 vol% CO2) below the tolerated limit of the DIS (difference < or = 0.2 vol

  4. Alarm symptoms and identification of non-cancer diagnoses in primary care: cohort study

    PubMed Central

    Charlton, Judith; Latinovic, Radoslav; Gulliford, Martin C

    2009-01-01

    Objective To evaluate the predictive value of alarm symptoms for specified non-cancer diagnoses and cancer diagnoses in primary care. Design Cohort study using the general practice research database. Setting 128 general practices in the UK contributing data, 1994-2000. Participants 762 325 patients aged 15 or older. Main outcome measures Up to 15 pre-specified, non-cancer diagnoses associated with four alarm symptoms (haematuria, haemoptysis, dysphagia, rectal bleeding) at 90 days and three years after the first recorded alarm symptom. For each outcome analyses were implemented separately in a time to event framework. Data were censored if patients died, left the practice, or reached the end of the study period. Results We analysed data on first episodes of haematuria (11 108), haemoptysis (4812), dysphagia (5999), or rectal bleeding (15 289). Non-cancer diagnoses were common in patients who presented with alarm symptoms. The proportion diagnosed with either cancer or non-cancer diagnoses generally increased with age. In patients presenting with haematuria, the proportions diagnosed with either cancer or non-cancer diagnoses within 90 days were 17.5% (95% confidence interval 16.4% to 18.6%) in women and 18.3% (17.4% to 19.3%) in men. For the other symptoms the proportions were 25.7% (23.8% to 27.8%) and 24% (22.5% to 25.6%) for haemoptysis, 17.2% (16% to 18.5%) and 22.6% (21% to 24.3%) for dysphagia, and 14.5% (13.7% to 15.3%) and 16.7% (15.8% to 17.5%) for rectal bleeding. Conclusion Clinically relevant diagnoses are made in a high proportion of patients presenting with alarm symptoms. For every four to seven patients evaluated for haematuria, haemoptysis, dysphagia, or rectal bleeding, relevant diagnoses will be identified in one patient within 90 days. PMID:19679615

  5. Collection and evaluation of false alarm signatures in background data

    NASA Astrophysics Data System (ADS)

    Agarwal, Sanjeev; Vulli, Shivakar; Malloy, Neil J.; Lord, Elizabeth M.; Fairley, Josh R.; Sabol, Bruce M.; Johnson, Wesley; Ess, Richard; Trang, Anh H.

    2009-05-01

    A significant amount of background airborne data was collected as part of May 2005 tests for airborne minefield detection at an arid site. The locations of false alarms which occurred consistently during different runs, were identified and geo-referenced by MultiSensor Science LLC. Ground truth information, which included pictures, type qualifiers and some hyperspectral data for these identified false alarm locations, was surveyed by ERDC-WES. This collection of background data, and subsequent survey of the false alarm locations, is unique in that it is likely the first such airborne data collection with ground truthed and documented false alarm locations. A library of signatures for different sources of these false alarms was extracted in the form of image chips and organized into a self-contained database by Missouri S&T. The library contains target chips from airborne mid wave infrared (MWIR) and multispectral imaging (MSI) sensors, representing data for different days, different times of day and different altitudes. Target chips for different surface mines were also added to the database. This database of the target signatures is expected to facilitate evaluation of spectral and shape characteristics of the false alarms, to achieve better false alarm mitigation and improve mine and minefield detection for airborne applications. The aim of this paper is to review and summarize the data collection procedure used, present the currently available database of target chips and make some recommendations regarding future data collections.

  6. Computational Human Performance Modeling For Alarm System Design

    SciTech Connect

    Jacques Hugo

    2012-07-01

    The introduction of new technologies like adaptive automation systems and advanced alarms processing and presentation techniques in nuclear power plants is already having an impact on the safety and effectiveness of plant operations and also the role of the control room operator. This impact is expected to escalate dramatically as more and more nuclear power utilities embark on upgrade projects in order to extend the lifetime of their plants. One of the most visible impacts in control rooms will be the need to replace aging alarm systems. Because most of these alarm systems use obsolete technologies, the methods, techniques and tools that were used to design the previous generation of alarm system designs are no longer effective and need to be updated. The same applies to the need to analyze and redefine operators’ alarm handling tasks. In the past, methods for analyzing human tasks and workload have relied on crude, paper-based methods that often lacked traceability. New approaches are needed to allow analysts to model and represent the new concepts of alarm operation and human-system interaction. State-of-the-art task simulation tools are now available that offer a cost-effective and efficient method for examining the effect of operator performance in different conditions and operational scenarios. A discrete event simulation system was used by human factors researchers at the Idaho National Laboratory to develop a generic alarm handling model to examine the effect of operator performance with simulated modern alarm system. It allowed analysts to evaluate alarm generation patterns as well as critical task times and human workload predicted by the system.

  7. Frog Swarms: Earthquake Precursors or False Alarms?

    PubMed Central

    Grant, Rachel A.; Conlan, Hilary

    2013-01-01

    Simple Summary Media reports linking unusual animal behaviour with earthquakes can potentially create false alarms and unnecessary anxiety among people that live in earthquake risk zones. Recently large frog swarms in China and elsewhere have been reported as earthquake precursors in the media. By examining international media reports of frog swarms since 1850 in comparison to earthquake data, it was concluded that frog swarms are naturally occurring dispersal behaviour of juveniles and are not associated with earthquakes. However, the media in seismic risk areas may be more likely to report frog swarms, and more likely to disseminate reports on frog swarms after earthquakes have occurred, leading to an apparent link between frog swarms and earthquakes. Abstract In short-term earthquake risk forecasting, the avoidance of false alarms is of utmost importance to preclude the possibility of unnecessary panic among populations in seismic hazard areas. Unusual animal behaviour prior to earthquakes has been reported for millennia but has rarely been scientifically documented. Recently large migrations or unusual behaviour of amphibians have been linked to large earthquakes, and media reports of large frog and toad migrations in areas of high seismic risk such as Greece and China have led to fears of a subsequent large earthquake. However, at certain times of year large migrations are part of the normal behavioural repertoire of amphibians. News reports of “frog swarms” from 1850 to the present day were examined for evidence that this behaviour is a precursor to large earthquakes. It was found that only two of 28 reported frog swarms preceded large earthquakes (Sichuan province, China in 2008 and 2010). All of the reported mass migrations of amphibians occurred in late spring, summer and autumn and appeared to relate to small juvenile anurans (frogs and toads). It was concluded that most reported “frog swarms” are actually normal behaviour, probably caused by

  8. SCADA alarms processing for wind turbine component failure detection

    NASA Astrophysics Data System (ADS)

    Gonzalez, E.; Reder, M.; Melero, J. J.

    2016-09-01

    Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.

  9. Male rats respond to their own alarm pheromone.

    PubMed

    Inagaki, Hideaki; Kiyokawa, Yasushi; Takeuchi, Yukari; Mori, Yuji

    2012-01-01

    Pheromones are defined as substances released from an individual (donor) that influence a second individual (recipient) of the same species. However, it is unclear whether mammalian pheromones can affect the donor itself. To address this question, the effect of self-exposure to an alarm pheromone was examined. Exposure to the alarm pheromone resulted in an enhanced anxiety response, which was not different between recipients that perceived their own pheromone and those that perceived another individual's pheromone. The present results suggest that the alarm pheromone influences the emotional system of the recipient as well as induces similar anxiogenic effects on the donor rat that released the alarm pheromone. This is the first evidence demonstrating the effectiveness of mammalian pheromone self-exposure.

  10. Audibility of patient clinical alarms to hospital nursing personnel.

    PubMed

    Sobieraj, Josef; Ortega, Claudia; West, Iris; Voepel, Leo; Battle, Steven; Robinson, DaShawn

    2006-04-01

    The audibility of patient clinical alarms to nursing personnel was tested during the first shift on a medical/surgical in-patient ward at William Beaumont Army Medical Center. This study was conducted during normal hospital operations, and we tested the Joint Commission on Accreditation of Healthcare Organizations 2004 National Patient Safety Goal, Section 6b to determine whether patient alarms could sufficiently compete against environmental background noises. Patient clinical alarms were audible at distances of > or = 95 feet with room doors open but were not sufficiently audible to hospital staff members when room doors were closed or during floor-buffing activities. This study suggests that, under these circumstances, hospitals may not meet Joint Commission on Accreditation of Healthcare Organizations 2004 National Patient Safety Goal, Section 6b. Because the audibility of patient clinical alarms directly affects patient safety, satisfaction, and quality of care, we provide recommendations for engineering controls and modifications to work routines.

  11. Wireless intelligent alarm technology with pyroelectric infrared sensor

    NASA Astrophysics Data System (ADS)

    Chen, Xiao

    2009-07-01

    Aiming at the defects of monitoring conducted by man in the conventional practice, we study the passive intelligent automatic alarm technology based on the pyroelectric infrared sensor and wireless communication technology. The designed passive infrared wireless alarm is composed of pyroelectric infrared sensors, infrared special chip BISS0001 and their peripheral circuits. When someone enters into the detecting and monitoring range, the alarm will detect the infrared ray of the human radiation by the contactless form and detect the signals of circuit output. Then it translates them into low frequency signals relative with human sports speed, distance and direction, produce corresponding output signals through amplifying by the back state controller, switch on the work power of the wireless transmitting circuit and make it emit the alarm signals. The system enhances the monitoring level and effects and possesses many advantages such as wide detecting range, long detecting distance and high reliability.

  12. Measurement of the Portsmouth Gaseous Diffusion Plant criticality accident alarm

    SciTech Connect

    Tayloe, R.W. Jr. ); McGinnis, B. )

    1990-08-31

    Measurements of the Portsmouth Gaseous Diffusion Plant's nuclear criticality accident radiation alarm signal response time, sound wave frequency, and sound volume levels were made to demonstrate compliance with ANSI/ANS-8.3-1986. A steady-state alarm signal is produced within one-half second of obtaining a two-out-of-three detector trip. The fundamental alarm sound wave frequency is 440 hertz. The sound volume levels are greater than 10 decibels above background and ranged from 100 to 125 A-weighted decibels. The requirements of the standard were met; however the recommended maximum sound volume level of 115 dBA was exceeded. Emergency procedures require immediate evacuation upon initiation of a facility's radiation alarm. Comparison with standards for allowable time of exposure at different noise levels indicate that the elevated noise level at this location does not represent an occupational injury hazard. 8 refs., 5 figs.

  13. 18. DETAIL VIEW OF FIRE ALARM SYSTEM BOARD THAT LISTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. DETAIL VIEW OF FIRE ALARM SYSTEM BOARD THAT LISTS AREAS IN SHOPS COMPLEX. - Baltimore & Ohio Railroad, Mount Clare Shops, South side of Pratt Street between Carey & Poppleton Streets, Baltimore, Independent City, MD

  14. Design and development of a personal alarm monitor for use by first responders

    NASA Astrophysics Data System (ADS)

    Ehntholt, Daniel J.; Louie, Alan S.; Marenchic, Ingrid G.; Forni, Ronald J.

    2004-03-01

    This paper describes the design and development of a small, portable alarm device that can be used by first responders to an emergency event to warn of the presence of low levels of a toxic nerve gas. The device consists of a rigid reusable portion and a consumable packet that is sensitive to the presence of acetylcholinesterase inhibitors such as the nerve gases Sarin or Soman. The sensitivity level of the alarm is set to be at initial physiological response at the meiosis level, orders of magnitude below lethal concentrations. The AChE enzyme used is specific for nerve-type toxins. A color development reaction is used to demonstrate continued activity of the enzyme over its twelve-hour operational cycle.

  15. Heterospecific alarm call recognition in a non-vocal reptile.

    PubMed

    Vitousek, Maren N; Adelman, James S; Gregory, Nathan C; Clair, James J H St

    2007-12-22

    The ability to recognize and respond to the alarm calls of heterospecifics has previously been described only in species with vocal communication. Here we provide evidence that a non-vocal reptile, the Galápagos marine iguana (Amblyrhynchus cristatus), can eavesdrop on the alarm call of the Galápagos mockingbird (Nesomimus parvulus) and respond with anti-predator behaviour. Eavesdropping on complex heterospecific communications demonstrates a remarkable degree of auditory discrimination in a non-vocal species.

  16. The calibration and the monitoring/alarm system

    NASA Astrophysics Data System (ADS)

    Cappella, F.; Caracciolo, V.; Cerulli, R.; Bussolotti, A.; Mattei, A.

    2016-10-01

    Two important parts of the DAMA/LIBRA setup are the calibration system and the monitoring/alarm system. The calibration system allows to perform detector calibrations without changing the running condition of the experiment; the monitoring/alarm system allows to record several parameters to control the running status and its stability. In this paper, we will describe the two system reporting some related obtained results.

  17. Open-source point-of-care electronic medical records for use in resource-limited settings: systematic review and questionnaire surveys

    PubMed Central

    Bru, Juan; Berger, Christopher A

    2012-01-01

    Background Point-of-care electronic medical records (EMRs) are a key tool to manage chronic illness. Several EMRs have been developed for use in treating HIV and tuberculosis, but their applicability to primary care, technical requirements and clinical functionalities are largely unknown. Objectives This study aimed to address the needs of clinicians from resource-limited settings without reliable internet access who are considering adopting an open-source EMR. Study eligibility criteria Open-source point-of-care EMRs suitable for use in areas without reliable internet access. Study appraisal and synthesis methods The authors conducted a comprehensive search of all open-source EMRs suitable for sites without reliable internet access. The authors surveyed clinician users and technical implementers from a single site and technical developers of each software product. The authors evaluated availability, cost and technical requirements. Results The hardware and software for all six systems is easily available, but they vary considerably in proprietary components, installation requirements and customisability. Limitations This study relied solely on self-report from informants who developed and who actively use the included products. Conclusions and implications of key findings Clinical functionalities vary greatly among the systems, and none of the systems yet meet minimum requirements for effective implementation in a primary care resource-limited setting. The safe prescribing of medications is a particular concern with current tools. The dearth of fully functional EMR systems indicates a need for a greater emphasis by global funding agencies to move beyond disease-specific EMR systems and develop a universal open-source health informatics platform. PMID:22763661

  18. Perimeter security alarm system based on fiber Bragg grating

    NASA Astrophysics Data System (ADS)

    Zhang, Cui; Wang, Lixin

    2010-11-01

    With the development of the society and economy and the improvement of living standards, people need more and more pressing security. Perimeter security alarm system is widely regarded as the first line of defense. A highly sensitive Fiber Bragg grating (FBG) vibration sensor based on the theory of the string vibration, combined with neural network adaptive dynamic programming algorithm for the perimeter security alarm system make the detection intelligently. Intelligent information processing unit identify the true cause of the vibration of the invasion or the natural environment by analyzing the frequency of vibration signals, energy, amplitude and duration. Compared with traditional perimeter security alarm systems, such as infrared perimeter security system and electric fence system, FBG perimeter security alarm system takes outdoor passive structures, free of electromagnetic interference, transmission distance through optical fiber can be as long as 20 km It is able to detect the location of event within short period of time (high-speed response, less than 3 second).This system can locate the fiber cable's breaking sites and alarm automatically if the cable were be cut. And the system can prevent effectively the false alarm from small animals, birds, strong wind, scattering things, snowfalls and vibration of sensor line itself. It can also be integrated into other security systems. This system can be widely used in variety fields such as military bases, nuclear sites, airports, warehouses, prisons, residence community etc. It will be a new force of perimeter security technology.

  19. A case of shotgun injury which occurred while an unconventional home security alarm system was being checked.

    PubMed

    Asirdizer, Mahmut; Yavuz, Mehmet Sunay

    2009-11-20

    Installation of devices involving shotguns is rarely encountered in forensic medicine practice. In this case report, authors aimed to present an unusual and rare case of shotgun injury due to a home security alarm system and its legal assessment. An electrical technician was invited to a summer house to check a home security alarm system installed by another firm which he worked for previously. It was an unconventional home security alarm system attached to a shotgun. The technician was injured with 18 buckshot pellets (no: 4) while checking the system. The host was convicted of a possible intent to cause a life-threatening injury to the technician. We think that this verdict will set a precedent for similar cases.

  20. Point-of-Care Diagnostics in Low-Resource Settings and Their Impact on Care in the Age of the Noncommunicable and Chronic Disease Epidemic.

    PubMed

    Weigl, Bernhard H; Neogi, Tina; McGuire, Helen

    2014-06-01

    The emergence of point-of-care (POC) diagnostics specifically designed for low-resource settings coupled with the rapid increase in need for routine care of patients with chronic diseases should prompt reconsideration of how health care can be delivered most beneficially and cost-effectively in developing countries. Bolstering support for primary care to provide rapid and appropriate integrated acute and chronic care treatment may be a possible solution. POC diagnostics can empower local and primary care providers and enable them to make better clinical decisions. This article explores the opportunity for POC diagnostics to strengthen primary care and chronic disease diagnosis and management in a low-resource setting (LRS) to deliver appropriate, consistent, and integrated care. We analyze the requirements of resource-appropriate chronic disease care, the characteristics of POC diagnostics in LRS versus the developed world, the many roles of diagnostics in the care continuum in LRS, and the process and economics of developing LRS-compatible POC diagnostics.

  1. Automatic sets and Delone sets

    NASA Astrophysics Data System (ADS)

    Barbé, A.; von Haeseler, F.

    2004-04-01

    Automatic sets D\\subset{\\bb Z}^m are characterized by having a finite number of decimations. They are equivalently generated by fixed points of certain substitution systems, or by certain finite automata. As examples, two-dimensional versions of the Thue-Morse, Baum-Sweet, Rudin-Shapiro and paperfolding sequences are presented. We give a necessary and sufficient condition for an automatic set D\\subset{\\bb Z}^m to be a Delone set in {\\bb R}^m . The result is then extended to automatic sets that are defined as fixed points of certain substitutions. The morphology of automatic sets is discussed by means of examples.

  2. 46 CFR 108.627 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 108.627 Section... UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide and clean agent alarms. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT...

  3. 46 CFR 108.627 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 108.627 Section... UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide and clean agent alarms. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT...

  4. 46 CFR 108.627 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 108.627 Section... UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide and clean agent alarms. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT...

  5. Effect of setting high APRV guided by expiratory inflection point of pressure-volume curve on oxygen delivery in canine models of severe acute respiratory distress syndrome

    PubMed Central

    Li, Jia-Qiong; Xu, Hong-Yang; Li, Mao-Qin; Chen, Jing-Yu

    2016-01-01

    In the present study, the effect of setting high airway pressure release ventilation (APRV) pressure guided by an expiratory inflection point of pressure-volume (PV) curve following lung recruitment maneuver (RM) on oxygen delivery (DO2) in canine models of severe acute respiratory distress syndrome (ARDS) was examined. Canine models of severe ARDS were established by intravenous injection of oleic acid. After injection of sedative muscle relaxants, a PV curve plotted using the super-syringe technique, and the pressure at lower inflection point (LIP) at the inhale branch and the pressure at the point of maximum curvature (PMC) at the exhale branch were measured. The ventilation mode was biphasic positive airway pressure (BiPAP), an inspiration to expiration ratio of 1:2, and Phigh 40 cm H2O, Plow 25 cm H2O. Phigh was decreased to 30 cm H2O after 90 sec. The dogs were randomized into 3 groups after RM, i.e., Blip group, BiPAP Plow = LIP+2 cm H2O; Bpmc group, BiPAP Plow = PMC; and Apmc group. In the APRV group, Phigh was set as PMC, with an inspiratory duration of 4 sec and expiratory duration of 0.4 sec. PMC was 18±1.4 cm H2O, and LIP was 11±1.3 cm H2O. Thirty seconds after RM was stabilized, it was set as 0 h. Hemodynamics, oxygenation and DO2 were measured at 0, 1, 2 and 4 h after RM in ARDS dogs. The results demonstrated: i) cardiac index (CI) in the 3 groups, where CI was significantly decreased in the Bpmc group at 0, 1, 2 and 4 h after RM compared to prior to RM (P<0.05) as well as in the Blip and Apmc groups (P<0.05). CI in the Blip and Apmc groups was not significantly altered prior to and after RM. ii) Oxygenation at 0, 1, 2 and 4 h in the 3 groups was improved after RM and the oxygenation indices for the 3 groups at 1 and 2 h were not significantly different (P>0.05). However, the oxygenation index in the Blip group at 4 h was significantly lower than those at 0 h for the Apmc and Bpmc groups (P<0.05). Oxygenation for the Apmc group at 4 h was higher

  6. Fault Diagnosis with Multi-State Alarms in a Nuclear Power Control Simulation

    SciTech Connect

    Stuart A. Ragsdale; Roger Lew; Ronald L. Boring

    2014-09-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effects of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized the use of three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. Sensitivity and criterion based on the Signal Detection Theory were used to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

  7. FAULT DIAGNOSIS WITH MULTI-STATE ALARMS IN A NUCLEAR POWER CONTROL SIMULATOR

    SciTech Connect

    Austin Ragsdale; Roger Lew; Brian P. Dyre; Ronald L. Boring

    2012-10-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effect of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. We used sensitivity and criterion based on Signal Detection Theory to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

  8. Reducing SCADA System Nuisance Alarms in the Water Industry in Northern Ireland.

    PubMed

    O'Donoghue, Nigel; Phillips, Debra H; Nicell, Ciaran

    2015-08-01

    The advancement of telemetry control for the water industry has increased the difficulty of managing large volumes of nuisance alarms (i.e., alarms that do not require a response). The aim of this study was to identify and reduce the number of nuisance alarms that occur for Northern Ireland (NI) Water by carrying out alarm duration analysis to determine the appropriate length of persistence (an advanced alarm management tool) that could be applied. All data were extracted from TelemWeb (NI Water's telemetry monitoring system) and analyzed in Excel. Over a 6-week period, an average of 40 000 alarms occurred per week. The alarm duration analysis, which has never been implemented before by NI Water, found that an average of 57% of NI Water alarms had a duration of <5 minutes. Applying 5-minute persistence, therefore, could prevent an average 26 816 nuisance alarms per week. Most of these alarms were from wastewater assets.

  9. Nuclear-power-plant perimeter-intrusion alarm systems

    SciTech Connect

    Halsey, D.J.

    1982-04-01

    Timely intercept of an intruder requires the examination of perimeter barriers and sensors in terms of reliable detection, immediate assessment and prompt response provisions. Perimeter security equipment and operations must at the same time meet the requirements of the Code of Federal Regulations, 10 CFR 73.55 with some attention to the performance and testing figures of Nuclear Regulatory Guide 5.44, Revision 2, May 1980. A baseline system is defined which recommends a general approach to implementing perimeter security elements: barriers, lighting, intrusion detection, alarm assessment. The baseline approach emphasizes cost/effectiveness achieved by detector layering and logic processing of alarm signals to produce reliable alarms and low nuisance alarm rates. A cost benefit of layering along with video assessment is reduction in operating expense. The concept of layering is also shown to minimize testing costs where detectability performance as suggested by Regulatory Guide 5.44 is to be performed. Synthesis of the perimeter intrusion alarm system and limited testing of CCTV and Video Motion Detectors (VMD), were performed at E-Systems, Greenville Division, Greenville, Texas during 1981.

  10. Panic, Suffocation False Alarms, Separation Anxiety and Endogenous Opioids

    PubMed Central

    Preter, Maurice; Klein, Donald F.

    2008-01-01

    This review paper presents an amplification of the suffocation false alarm theory (SFA) of spontaneous panic (Klein, 1993). SFA postulates the existence of an evolved physiologic suffocation alarm system that monitors information about potential suffocation. Panic attacks maladaptively occur when the alarm is erroneously triggered. That panic is distinct from Cannon’s emergency fear response and Selye’s General Alarm Syndrome is shown by the prominence of intense air hunger during these attacks. Further, panic sufferers have chronic sighing abnormalities outside of the acute attack. Another basic physiologic distinction between fear and panic is the counter-intuitive lack of hypothalamic-pituitary-adrenal (HPA) activation in panic. Understanding panic as provoked by indicators of potential suffocation, such as fluctuations in pCO2 and brain lactate, as well as environmental circumstances fits the observed respiratory abnormalities. However, that sudden loss, bereavement and childhood separation anxiety are also antecedents of “spontaneous” panic requires an integrative explanation. Because of the opioid system’s central regulatory role in both disordered breathing and separation distress, we detail the role of opioidergic dysfunction in decreasing the suffocation alarm threshold. We present results from our laboratory where the naloxone-lactate challenge in normals produces supportive evidence for the endorphinergic defect hypothesis in the form of a distress episode of specific tidal volume hyperventilation paralleling challenge-produced and clinical panic. PMID:17765379

  11. Controlling misses and false alarms in a machine learning framework for predicting uniformity of printed pages

    NASA Astrophysics Data System (ADS)

    Nguyen, Minh Q.; Allebach, Jan P.

    2015-01-01

    In our previous work1 , we presented a block-based technique to analyze printed page uniformity both visually and metrically. The features learned from the models were then employed in a Support Vector Machine (SVM) framework to classify the pages into one of the two categories of acceptable and unacceptable quality. In this paper, we introduce a set of tools for machine learning in the assessment of printed page uniformity. This work is primarily targeted to the printing industry, specifically the ubiquitous laser, electrophotographic printer. We use features that are well-correlated with the rankings of expert observers to develop a novel machine learning framework that allows one to achieve the minimum "false alarm" rate, subject to a chosen "miss" rate. Surprisingly, most of the research that has been conducted on machine learning does not consider this framework. During the process of developing a new product, test engineers will print hundreds of test pages, which can be scanned and then analyzed by an autonomous algorithm. Among these pages, most may be of acceptable quality. The objective is to find the ones that are not. These will provide critically important information to systems designers, regarding issues that need to be addressed in improving the printer design. A "miss" is defined to be a page that is not of acceptable quality to an expert observer that the prediction algorithm declares to be a "pass". Misses are a serious problem, since they represent problems that will not be seen by the systems designers. On the other hand, "false alarms" correspond to pages that an expert observer would declare to be of acceptable quality, but which are flagged by the prediction algorithm as "fails". In a typical printer testing and development scenario, such pages would be examined by an expert, and found to be of acceptable quality after all. "False alarm" pages result in extra pages to be examined by expert observers, which increases labor cost. But "false

  12. Projections onto Convex Sets Super-Resolution Reconstruction Based on Point Spread Function Estimation of Low-Resolution Remote Sensing Images

    PubMed Central

    Fan, Chong; Wu, Chaoyun; Li, Grand; Ma, Jun

    2017-01-01

    To solve the problem on inaccuracy when estimating the point spread function (PSF) of the ideal original image in traditional projection onto convex set (POCS) super-resolution (SR) reconstruction, this paper presents an improved POCS SR algorithm based on PSF estimation of low-resolution (LR) remote sensing images. The proposed algorithm can improve the spatial resolution of the image and benefit agricultural crop visual interpolation. The PSF of the high-resolution (HR) image is unknown in reality. Therefore, analysis of the relationship between the PSF of the HR image and the PSF of the LR image is important to estimate the PSF of the HR image by using multiple LR images. In this study, the linear relationship between the PSFs of the HR and LR images can be proven. In addition, the novel slant knife-edge method is employed, which can improve the accuracy of the PSF estimation of LR images. Finally, the proposed method is applied to reconstruct airborne digital sensor 40 (ADS40) three-line array images and the overlapped areas of two adjacent GF-2 images by embedding the estimated PSF of the HR image to the original POCS SR algorithm. Experimental results show that the proposed method yields higher quality of reconstructed images than that produced by the blind SR method and the bicubic interpolation method. PMID:28208837

  13. Adaptive Changes of the Insig1/SREBP1/SCD1 Set Point Help Adipose Tissue to Cope With Increased Storage Demands of Obesity

    PubMed Central

    Carobbio, Stefania; Hagen, Rachel M.; Lelliott, Christopher J.; Slawik, Marc; Medina-Gomez, Gema; Tan, Chong-Yew; Sicard, Audrey; Atherton, Helen J.; Barbarroja, Nuria; Bjursell, Mikael; Bohlooly-Y, Mohammad; Virtue, Sam; Tuthill, Antoinette; Lefai, Etienne; Laville, Martine; Wu, Tingting; Considine, Robert V.; Vidal, Hubert; Langin, Dominique; Oresic, Matej; Tinahones, Francisco J.; Fernandez-Real, Jose Manuel; Griffin, Julian L.; Sethi, Jaswinder K.; López, Miguel; Vidal-Puig, Antonio

    2013-01-01

    The epidemic of obesity imposes unprecedented challenges on human adipose tissue (WAT) storage capacity that may benefit from adaptive mechanisms to maintain adipocyte functionality. Here, we demonstrate that changes in the regulatory feedback set point control of Insig1/SREBP1 represent an adaptive response that preserves WAT lipid homeostasis in obese and insulin-resistant states. In our experiments, we show that Insig1 mRNA expression decreases in WAT from mice with obesity-associated insulin resistance and from morbidly obese humans and in in vitro models of adipocyte insulin resistance. Insig1 downregulation is part of an adaptive response that promotes the maintenance of SREBP1 maturation and facilitates lipogenesis and availability of appropriate levels of fatty acid unsaturation, partially compensating the antilipogenic effect associated with insulin resistance. We describe for the first time the existence of this adaptive mechanism in WAT, which involves Insig1/SREBP1 and preserves the degree of lipid unsaturation under conditions of obesity-induced insulin resistance. These adaptive mechanisms contribute to maintain lipid desaturation through preferential SCD1 regulation and facilitate fat storage in WAT, despite on-going metabolic stress. PMID:23919961

  14. Aging is a simple deprivation syndrome driven by a quasi-programmed preventable and reversible drift of control system set points due to inappropriate organism-environment interaction.

    PubMed

    Khalyavkin, A V; Krutko, V N

    2014-10-01

    There are two well-known but opposing concepts of the reason for aging. The first supposes that senescence is programmed similarly to the genetic program of development from a zygote up to a mature organism. Genetically determined senile wasting is thought to be associated with the necessity to renovate the population to ensure its adaptation and survival. According to the concept of the stochastic aging (due to accumulation of occasional error and damage), there is no built-in program of aging. There is only a program of development up to the state of maturity, and then the organism should be able to maintain itself limitlessly. However, although the efficiency of repair systems is assumed to be rather high, it is less than 100%. Just this has to result in aging because of accumulation of various errors. We have continued and developed another approach that considers both programmed and stochastic concepts to be incorrect. Aging is a simple deprivation syndrome driven by preventable and even reversible drifts of control systems set points because of an inappropriate "organism-environment" interaction.

  15. Projections onto Convex Sets Super-Resolution Reconstruction Based on Point Spread Function Estimation of Low-Resolution Remote Sensing Images.

    PubMed

    Fan, Chong; Wu, Chaoyun; Li, Grand; Ma, Jun

    2017-02-13

    To solve the problem on inaccuracy when estimating the point spread function (PSF) of the ideal original image in traditional projection onto convex set (POCS) super-resolution (SR) reconstruction, this paper presents an improved POCS SR algorithm based on PSF estimation of low-resolution (LR) remote sensing images. The proposed algorithm can improve the spatial resolution of the image and benefit agricultural crop visual interpolation. The PSF of the highresolution (HR) image is unknown in reality. Therefore, analysis of the relationship between the PSF of the HR image and the PSF of the LR image is important to estimate the PSF of the HR image by using multiple LR images. In this study, the linear relationship between the PSFs of the HR and LR images can be proven. In addition, the novel slant knife-edge method is employed, which can improve the accuracy of the PSF estimation of LR images. Finally, the proposed method is applied to reconstruct airborne digital sensor 40 (ADS40) three-line array images and the overlapped areas of two adjacent GF-2 images by embedding the estimated PSF of the HR image to the original POCS SR algorithm. Experimental results show that the proposed method yields higher quality of reconstructed images than that produced by the blind SR method and the bicubic interpolation method.

  16. Design of set-point weighting PI{sup λ} + D{sup μ} controller for vertical magnetic flux controller in Damavand tokamak

    SciTech Connect

    Rasouli, H.; Fatehi, A.

    2014-12-15

    In this paper, a simple method is presented for tuning weighted PI{sup λ} + D{sup μ} controller parameters based on the pole placement controller of pseudo-second-order fractional systems. One of the advantages of this controller is capability of reducing the disturbance effects and improving response to input, simultaneously. In the following sections, the performance of this controller is evaluated experimentally to control the vertical magnetic flux in Damavand tokamak. For this work, at first a fractional order model is identified using output-error technique in time domain. For various practical experiments, having desired time responses for magnetic flux in Damavand tokamak, is vital. To approach this, at first the desired closed loop reference models are obtained based on generalized characteristic ratio assignment method in fractional order systems. After that, for the identified model, a set-point weighting PI{sup λ} + D{sup μ} controller is designed and simulated. Finally, this controller is implemented on digital signal processor control system of the plant to fast/slow control of magnetic flux. The practical results show appropriate performance of this controller.

  17. The function of nonlinear phenomena in meerkat alarm calls.

    PubMed

    Townsend, Simon W; Manser, Marta B

    2011-02-23

    Nonlinear vocal phenomena are a ubiquitous feature of human and non-human animal vocalizations. Although we understand how these complex acoustic intrusions are generated, it is not clear whether they function adaptively for the animals producing them. One explanation is that nonlinearities make calls more unpredictable, increasing behavioural responses and ultimately reducing the chances of habituation to these call types. Meerkats (Suricata suricatta) exhibit nonlinear subharmonics in their predator alarm calls. We specifically tested the 'unpredictability hypothesis' by playing back naturally occurring nonlinear and linear medium-urgency alarm call bouts. Results indicate that subjects responded more strongly and foraged less after hearing nonlinear alarm calls. We argue that these findings support the unpredictability hypothesis and suggest this is the first study in animals or humans to show that nonlinear vocal phenomena function adaptively.

  18. The "suffocation alarm" theory of panic attacks: a critical commentary.

    PubMed

    Ley, R

    1994-12-01

    In 1993 Klein proposed a "false suffocation alarm" theory of panic attacks, claiming that many spontaneous panic attacks are due to a "suffocation monitor" in the brain erroneously signaling a lack of useful air, and triggering an evolved "suffocation alarm system". He proposed that carbon dioxide acts as a panic stimulus because rising arterial CO2 suggests suffocation may be imminent." The present paper provides a critical analysis of Klein's theory and concludes that there is neither empirical evidence nor compelling argument to support the assumptions or the proposed neurological mechanism of a "suffocation alarm", true or false, or a CO2 "suffocation monitor." Data relevant to the role of breathing in the phenomenon of panic can be parsimoniously subsumed within the domain of dyspnea.

  19. The function of nonlinear phenomena in meerkat alarm calls

    PubMed Central

    Townsend, Simon W.; Manser, Marta B.

    2011-01-01

    Nonlinear vocal phenomena are a ubiquitous feature of human and non-human animal vocalizations. Although we understand how these complex acoustic intrusions are generated, it is not clear whether they function adaptively for the animals producing them. One explanation is that nonlinearities make calls more unpredictable, increasing behavioural responses and ultimately reducing the chances of habituation to these call types. Meerkats (Suricata suricatta) exhibit nonlinear subharmonics in their predator alarm calls. We specifically tested the ‘unpredictability hypothesis’ by playing back naturally occurring nonlinear and linear medium-urgency alarm call bouts. Results indicate that subjects responded more strongly and foraged less after hearing nonlinear alarm calls. We argue that these findings support the unpredictability hypothesis and suggest this is the first study in animals or humans to show that nonlinear vocal phenomena function adaptively. PMID:20659926

  20. Field response of tadpoles to conspecific and heterospecific alarm

    USGS Publications Warehouse

    Adams, M.J.; Claeson, S.

    1998-01-01

    Many organisms use chemical cues from a variety of sources to mediate predator avoidance. Response to heterospecific alarm cues has been demonstrated for tadpoles within but not among taxa and alarm response behavior has seldom been examined under field conditions. This study examined the response of three sympatric amphibian larvae and predaceous larval Dytiscus sp. (diving beetle) to damage-release signals in natural ponds by using capture rates from treated funnel traps as an index of larval behavior. Hyla regilla (Pacific tree frog) tadpoles avoided traps treated with either crushed conspecifics or with Rana aurora (red-legged frog) tadpoles but the larger ranids and Arabystoma macrodactylum (long-toed salamander) did not respond to either treatment. H. regilla tadpoles were likely susceptible to any potential predators of ranid tadpoles in these ponds and this result is consistent with the hypothesis that a response to heterospecific alarm occurs in sympatric prey with shared predators.

  1. Neural Network False Alarm Filter. Volume 1.

    DTIC Science & Technology

    1994-12-01

    This effort identified, developed and demonstrated a set of approaches for applying neural network learning techniques to the development of a real... neural network models, 9 fault report causes and 12 common groups of BIT techniques was identified. From this space, 4 unique, high-potential...of their strengths and weaknesses were performed along with cost/ benefit analyses. This study concluded that the best candidates for neural network insert

  2. Anthropogenic noise alters dwarf mongoose responses to heterospecific alarm calls.

    PubMed

    Morris-Drake, Amy; Bracken, Anna M; Kern, Julie M; Radford, Andrew N

    2017-04-01

    Anthropogenic noise is an evolutionarily novel and widespread pollutant in both terrestrial and aquatic habitats. Despite increasing evidence that the additional noise generated by human activities can affect vocal communication, the majority of research has focused on the use of conspecific acoustic information, especially sexual signals. Many animals are known to eavesdrop on the alarm calls produced by other species, enhancing their likelihood of avoiding predation, but how this use of heterospecific information is affected by anthropogenic noise has received little empirical attention. Here, we use two field-based playback experiments on a habituated wild population of dwarf mongooses (Helogale parvula) to determine how anthropogenic noise influences the response of foragers to heterospecific alarm calls. We begin by demonstrating that dwarf mongooses respond appropriately to the alarm calls of sympatric chacma baboons (Papio ursinus) and tree squirrels (Paraxerus cepapi); fleeing only to the latter. We then show that mongoose foragers are less likely to exhibit this flee response to tree squirrel alarm calls during road-noise playback compared to ambient-sound playback. One explanation for the change in response is that noise-induced distraction or stress result in maladaptive behaviour. However, further analysis revealed that road-noise playback results in increased vigilance and that mongooses showing the greatest vigilance increase are those that do not subsequently exhibit a flee response to the alarm call. These individuals may therefore be acting appropriately: if the greater gathering of personal information indicates the absence of an actual predator despite an alarm call, the need to undertake costly fleeing behaviour can be avoided. Either way, our study indicates the potential for anthropogenic noise to interfere with the use of acoustic information from other species, and suggests the importance of considering how heterospecific networks are

  3. Molecular recognition in a diverse set of protein-ligand interactions studied with molecular dynamics simulations and end-point free energy calculations.

    PubMed

    Wang, Bo; Li, Liwei; Hurley, Thomas D; Meroueh, Samy O

    2013-10-28

    End-point free energy calculations using MM-GBSA and MM-PBSA provide a detailed understanding of molecular recognition in protein-ligand interactions. The binding free energy can be used to rank-order protein-ligand structures in virtual screening for compound or target identification. Here, we carry out free energy calculations for a diverse set of 11 proteins bound to 14 small molecules using extensive explicit-solvent MD simulations. The structure of these complexes was previously solved by crystallography and their binding studied with isothermal titration calorimetry (ITC) data enabling direct comparison to the MM-GBSA and MM-PBSA calculations. Four MM-GBSA and three MM-PBSA calculations reproduced the ITC free energy within 1 kcal·mol(-1) highlighting the challenges in reproducing the absolute free energy from end-point free energy calculations. MM-GBSA exhibited better rank-ordering with a Spearman ρ of 0.68 compared to 0.40 for MM-PBSA with dielectric constant (ε = 1). An increase in ε resulted in significantly better rank-ordering for MM-PBSA (ρ = 0.91 for ε = 10), but larger ε significantly reduced the contributions of electrostatics, suggesting that the improvement is due to the nonpolar and entropy components, rather than a better representation of the electrostatics. The SVRKB scoring function applied to MD snapshots resulted in excellent rank-ordering (ρ = 0.81). Calculations of the configurational entropy using normal-mode analysis led to free energies that correlated significantly better to the ITC free energy than the MD-based quasi-harmonic approach, but the computed entropies showed no correlation with the ITC entropy. When the adaptation energy is taken into consideration by running separate simulations for complex, apo, and ligand (MM-PBSAADAPT), there is less agreement with the ITC data for the individual free energies, but remarkably good rank-ordering is observed (ρ = 0.89). Interestingly, filtering MD snapshots by prescoring

  4. Results of LLNL investigation of NYCT data sets

    SciTech Connect

    Sale, K; Harrison, M; Guo, M; Groza, M

    2007-08-01

    Upon examination we have concluded that none of the alarms indicate the presence of a real threat. A brief history and results from our examination of the NYCT ASP occupancy data sets dated from 2007-05-14 19:11:07 to 2007-06-20 15:46:15 are presented in this letter report. When the ASP data collection campaign at NYCT was completed, rather than being shut down, the Canberra ASP annunciator box was unplugged leaving the data acquisition system running. By the time it was discovered that the ASP was still acquiring data about 15,000 occupancies had been recorded. Among these were about 500 alarms (classified by the ASP analysis system as either Threat Alarms or Suspect Alarms). At your request, these alarms have been investigated. Our conclusion is that none of the alarm data sets indicate the presence of a real threat (within statistics). The data sets (ICD1 and ICD2 files with concurrent JPEG pictures) were delivered to LLNL on a removable hard drive labeled FOUO. The contents of the data disk amounted to 53.39 GB of data requiring over two days for the standard LLNL virus checking software to scan before work could really get started. Our first step was to walk through the directory structure of the disk and create a database of occupancies. For each occupancy, the database was populated with the occupancy date and time, occupancy number, file path to the ICD1 data and the alarm ('No Alarm', 'Suspect Alarm' or 'Threat Alarm') from the ICD2 file along with some other incidental data. In an attempt to get a global understanding of what was going on, we investigated the occupancy information. The occupancy date/time and alarm type were binned into one-hour counts. These data are shown in Figures 1 and 2.

  5. Development of an Indicator Displacement Based Detection of Malaria Targeting HRP-II as Biomarker for Application in Point-of-Care Settings.

    PubMed

    Chakma, Babina; Jain, Priyamvada; Singh, Naveen K; Goswami, Pranab

    2016-10-18

    A novel label free spectrophotometric detection of malarial biomarker HRP-II following an indicator displacement assay has been developed. The assay is based on competitive displacement of murexide dye from its complex with Ni(2+) by HRP-II present in serum samples. The binding constant (Kd) discerned for the dye and HRP-II to Ni(2+) were 1.4 × 10(-6) M(-1) and 6.8 × 10(-9) M(-1), respectively. The progress of the reaction could be monitored from the change of color from orange (∼λ482 nm) to pink (∼λ515 nm) with the concomitant increase in HRP-II concentration in the mixture. A linear response (R(2) = 0.995) curve was generated by plotting the ratio of absorbance (λ515 nm/λ482 nm) against the HRP-II concentrations. The method offers to detect HRP-II as low as 1 pM without any interference from some common salts and the major protein, HSA, present in the blood serum. The detection method was reproduced in a microfluidic paper based analytical device (μPAD), fabricated by printing hydrophobic alkyl ketene dimer on a chromatographic paper to create hydrophilic microchannels, test zone, and sample application zone. The device offers to use a maximum sample volume of 20 ± 0.06 μL and detects HRP-II within 5 min with LOD of 30 ± 9.6 nM in a dynamic range of 10 to 100 nM. The method has thus immense potential to develop as rapid, selective, simple, portable, and inexpensive malarial diagnostic device for point-of-care and low resource setting applications.

  6. Evaluation of fire-safety programs that use 10-year smoke alarms.

    PubMed

    Jackson, Mark; Wilson, Jonathan; Akoto, Judith; Dixon, Sherry; Jacobs, David E; Ballesteros, Michael F

    2010-10-01

    The Centers for Disease Control and Prevention began funding a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in 1998. This program involves the installation of lithium-powered "10-year" smoke alarms in homes at high risk for fires and injuries. This study aimed to (1) determine among original SAIFE homes if the lithium-powered alarms were still present and functional 8-10 years after installation and (2) understand factors related to smoke alarm presence and functionality. Data on a total of 384 homes and 601 smoke alarms in five states were collected and analyzed. Only one-third of alarms were still functional; 37% of installed alarms were missing; and 30% of alarms were present, but not functioning. Alarms were less likely to be functioning if they were installed in the kitchen and if homes had a different resident at follow-up. Of the 351 alarms that were present and had a battery at the time of the evaluation, only 21% contained lithium-powered batteries. Of these, 78% were still functioning. Programs that install lithium-powered alarms should use units that have sealed-in batteries and "hush" buttons. Additionally, education should be given on smoke alarm maintenance that includes a message that batteries in these alarms should not be replaced. Lithium-powered smoke alarms should last up to 10 years if maintained properly.

  7. Combining Gravitational Wave Events with their Electromagnetic Counterparts: A Realistic Joint False-Alarm Rate

    NASA Astrophysics Data System (ADS)

    Ackley, Kendall; Eikenberry, Stephen; Klimenko, Sergey; LIGO Team

    2017-01-01

    We present a false-alarm rate for a joint detection of gravitational wave (GW) events and associated electromagnetic (EM) counterparts for Advanced LIGO and Virgo (LV) observations during the first years of operation. Using simulated GW events and their recostructed probability skymaps, we tile over the error regions using sets of archival wide-field telescope survey images and recover the number of astrophysical transients to be expected during LV-EM followup. With the known GW event injection coordinates we inject artificial electromagnetic (EM) sources at that site based on theoretical and observational models on a one-to-one basis. We calculate the EM false-alarm probability using an unsupervised machine learning algorithm based on shapelet analysis which has shown to be a strong discriminator between astrophysical transients and image artifacts while reducing the set of transients to be manually vetted by five orders of magnitude. We also show the performance of our method in context with other machine-learned transient classification and reduction algorithms, showing comparability without the need for a large set of training data opening the possibility for next-generation telescopes to take advantage of this pipeline for LV-EM followup missions.

  8. 46 CFR 119.530 - Bilge high level alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... visual and audible alarm at the operating station to indicate a high water level in each of the following... flooding from sea water piping within the space; and (3) A space with a non-watertight closure , such as a... operating station to indicate when any automatic bilge pump is operating....

  9. The Lighthouse Alarm and Locator trial - a pilot study.

    PubMed

    Melander-Wikman, A; Jansson, M; Hallberg, J; Mörtberg, C; Gard, G

    2007-01-01

    An important factor for health is the possibility to be active and mobile. To make this possible various kinds of support are needed. Integrating geographical information systems technology and user experiences is important in the development of more user-friendly positioning devices. The Lighthouse Alarm and Locator trial aimed to test a new mobile alarm system with additional functionality such as positioning and monitoring of vital signs which can be used regardless of location (in hospital, at home). The system was tested by elderly persons from a pensioner organisation and home care personnel answered up on the alarms. After the tests qualitative interviews were performed with the two groups. The results showed that their experiences of the new mobile alarm system could be described in three main categories: to be supervised, to feel safe and to be mobile. These categories formed a theme: Positioning - an ethical dilemma. The clients' mobility was perceived to increase. The personnel did not think that positioning was ethical but the clients (elderly) did.

  10. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems §...

  11. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  12. 47 CFR 80.317 - Radiotelegraph and radiotelephone alarm signals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress... attract the attention of the operator when there is no listening watch on the distress frequency. (b) The... attention of the person on watch or to actuate automatic devices giving the alarm....

  13. 47 CFR 80.317 - Radiotelegraph and radiotelephone alarm signals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress... attract the attention of the operator when there is no listening watch on the distress frequency. (b) The... attention of the person on watch or to actuate automatic devices giving the alarm....

  14. 47 CFR 80.317 - Radiotelegraph and radiotelephone alarm signals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress... attract the attention of the operator when there is no listening watch on the distress frequency. (b) The... attention of the person on watch or to actuate automatic devices giving the alarm....

  15. 47 CFR 80.317 - Radiotelegraph and radiotelephone alarm signals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress... attract the attention of the operator when there is no listening watch on the distress frequency. (b) The... attention of the person on watch or to actuate automatic devices giving the alarm....

  16. 47 CFR 80.317 - Radiotelegraph and radiotelephone alarm signals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress... attract the attention of the operator when there is no listening watch on the distress frequency. (b) The... attention of the person on watch or to actuate automatic devices giving the alarm....

  17. A Nonmonotonic Lag Function for False Alarms to Associates

    ERIC Educational Resources Information Center

    MacLeod, Colin M.; Nelson, Thomas O.

    1976-01-01

    Of all the studies examining recognition of semantically related words, none has systematically varied lag to test the straightforward prediction of a monotonic decrease in false alarms to new words semantically related to prior words. The present experiment, using semantic associates, tested this prediction. (Author)

  18. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  19. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  20. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  1. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems §...

  2. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  3. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emergency action plan, or for reaction time for safe escape of employees from the workplace or the immediate... light levels by all employees in the affected portions of the workplace. Tactile devices may be used to... communication system also serves as the employee alarm system, all emergency messages shall have priority...

  4. Cost-Effective School Alarm Systems. Security Topics Series.

    ERIC Educational Resources Information Center

    Kaufer, Steve

    This document outlines considerations in the selection of a cost-effective school-alarm system. Steps in the planning process include: conducting a district needs assessment; gathering input from all staff levels; consulting technical expertise; and selecting a security system that can be integrated with other site needs. It further describes the…

  5. Advanced Alarm Systems: Revision of Guidance and Its Technical Basis

    DTIC Science & Technology

    2000-11-01

    bulletins and information notices; inspection and investigative reports; licensee event reports; and Commission papers and their attachments. NRC...List System CANDU Canadian Deuterium Uranium CE Combustion Engineering CPIAS Critical Parameter Indication and Alarm System CRT cathode ray tube...strategy for CANDU plants, Davey et al., (1995) noted that warning of conditions potentially leading to upsets is enhanced by including rate and margin

  6. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  7. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... equipped or designed for future installation of a roof-mounted evaporative cooler or other equipment...) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed for use with a...

  8. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  9. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  10. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  11. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... performed using test fluids described in § 162.050-20. (3) The oil content of each sample must be measured... paragraphs (b)(2) of this section first using Test Fluid B and then again with Test Fluid C. Collect samples.... Any change in the bilge alarm reading is recorded. (d) Test No. 3A Sample Pressure or Flow Test....

  12. Integrated alarm annunciation and entry control systems -- Survey results

    SciTech Connect

    Clever, J.J.; Arakaki, L.H.; Monaco, F.M.; Juarros, L.E.; Quintana, G.R.

    1993-10-01

    This report provides the results and analyses of a detailed survey undertaken in Summer 1993 to address integrated intrusion detection alarm annunciation and entry control system issues. This survey was undertaken as a first attempt toward beginning to answer questions about integrated systems and commercial capabilities to meet or partially meet US Department of Energy (DOE) site needs.

  13. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... paragraph (d)(1) of this section are repeated. (2) The metering and water pumps of the test rig are stopped... alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15 minutes and then with a mixture of Test Fluid A and water in the following concentrations: 0 ppm, 15...

  14. 46 CFR 153.409 - High level alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... audible and visual alarm before the tank fills to 97 percent of its capacity; (b) That can be seen and heard where cargo transfer is controlled and on the open deck; (c) Whose operation can be checked prior to each loading; and (d) That must be marked as described in § 153.408(c)(6) with the legend...

  15. 46 CFR 153.409 - High level alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... audible and visual alarm before the tank fills to 97 percent of its capacity; (b) That can be seen and heard where cargo transfer is controlled and on the open deck; (c) Whose operation can be checked prior to each loading; and (d) That must be marked as described in § 153.408(c)(6) with the legend...

  16. Role of Large Clinical Datasets From Physiologic Monitors in Improving the Safety of Clinical Alarm Systems and Methodological Considerations: A Case From Philips Monitors

    PubMed Central

    Reed, Charles Calhoun; Staggers, Nancy

    2016-01-01

    Background Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. Objective This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. Methods At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Results Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. Conclusions The audit log is a function of current capabilities of the physiologic monitoring systems, monitor’s configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices’ log capacity. PMID:27694097

  17. Sounding the Alarm: Health in the Anthropocene.

    PubMed

    Butler, Colin D

    2016-06-30

    There is growing scientific and public recognition that human actions, directly and indirectly, have profoundly changed the Earth system, in a still accelerating process, increasingly called the "Anthropocene". Planetary transformation, including of the atmosphere, climate, ecosystems and biodiversity, has enormous implications for human health, many of which are deeply disturbing, especially in low-income settings. A few health consequences of the Anthropocene have been partially recognized, including within environmental epidemiology, but their long-term consequences remain poorly understood and greatly under-rated. For example Syria could be a "sentinel" population, giving a glimpse to a much wider dystopian future. Health-Earth is a research network, co-founded in 2014, which seeks, with other groups, to catalyse a powerful curative response by the wider health community. This paper builds on a symposium presented by Health-Earth members at the 2015 conference of the International Society for Environmental Epidemiology. It reviews and synthesizes parts of the large literature relevant to the interaction between the changing Earth system and human health. It concludes that this topic should be prominent within future environmental epidemiology and public health. Created by our species, these challenges may be soluble, but solutions require far more understanding and resources than are currently being made available.

  18. Sounding the Alarm: Health in the Anthropocene

    PubMed Central

    Butler, Colin D.

    2016-01-01

    There is growing scientific and public recognition that human actions, directly and indirectly, have profoundly changed the Earth system, in a still accelerating process, increasingly called the “Anthropocene”. Planetary transformation, including of the atmosphere, climate, ecosystems and biodiversity, has enormous implications for human health, many of which are deeply disturbing, especially in low-income settings. A few health consequences of the Anthropocene have been partially recognized, including within environmental epidemiology, but their long-term consequences remain poorly understood and greatly under-rated. For example Syria could be a “sentinel” population, giving a glimpse to a much wider dystopian future. Health-Earth is a research network, co-founded in 2014, which seeks, with other groups, to catalyse a powerful curative response by the wider health community. This paper builds on a symposium presented by Health-Earth members at the 2015 conference of the International Society for Environmental Epidemiology. It reviews and synthesizes parts of the large literature relevant to the interaction between the changing Earth system and human health. It concludes that this topic should be prominent within future environmental epidemiology and public health. Created by our species, these challenges may be soluble, but solutions require far more understanding and resources than are currently being made available. PMID:27376314

  19. A patterned and un-patterned minefield detection in cluttered environments using Markov marked point process

    NASA Astrophysics Data System (ADS)

    Trang, Anh; Agarwal, Sanjeev; Regalia, Phillip; Broach, Thomas; Smith, Thomas

    2007-04-01

    A typical minefield detection approach is based on a sequential processing employing mine detection and false alarm rejection followed by minefield detection. The current approach does not work robustly under different backgrounds and environment conditions because target signature changes with time and its performance degrades in the presence of high density of false alarms. The aim of this research will be to advance the state of the art in detection of both patterned and unpatterned minefield in high clutter environments. The proposed method seeks to combine false alarm rejection module and the minefield detection module of the current architecture by spatial-spectral clustering and inference module using a Markov Marked Point Process formulation. The approach simultaneously exploits the feature characteristics of the target signature and spatial distribution of the targets in the interrogation region. The method is based on the premise that most minefields can be characterized by some type of distinctive spatial distribution of "similar" looking mine targets. The minefield detection problem is formulated as a Markov Marked Point Process (MMPP) where the set of possible mine targets is divided into a possibly overlapping mixture of targets. The likelihood of the minefield depends simultaneously on feature characteristics of the target and their spatial distribution. A framework using "Belief Propagation" is developed to solve the minefield inference problem based on MMPP. Preliminary investigation using simulated data shows the efficacy of the approach.

  20. SILENE Benchmark Critical Experiments for Criticality Accident Alarm Systems

    SciTech Connect

    Miller, Thomas Martin; Reynolds, Kevin H.

    2011-01-01

    In October 2010 a series of benchmark experiments was conducted at the Commissariat a Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE [1] facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems (CAASs). This presentation will discuss the geometric configuration of these experiments and the quantities that were measured and will present some preliminary comparisons between the measured data and calculations. This series consisted of three single-pulsed experiments with the SILENE reactor. During the first experiment the reactor was bare (unshielded), but during the second and third experiments it was shielded by lead and polyethylene, respectively. During each experiment several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor, and some of these detectors were themselves shielded from the reactor by high-density magnetite and barite concrete, standard concrete, and/or BoroBond. All the concrete was provided by CEA Saclay, and the BoroBond was provided by Y-12 National Security Complex. Figure 1 is a picture of the SILENE reactor cell configured for pulse 1. Also included in these experiments were measurements of the neutron and photon spectra with two BICRON BC-501A liquid scintillators. These two detectors were provided and operated by CEA Valduc. They were set up just outside the SILENE reactor cell with additional lead shielding to prevent the detectors from being saturated. The final detectors involved in the experiments were two different types of CAAS detectors. The Babcock International Group provided three CIDAS CAAS detectors, which measured photon dose and dose rate with a Geiger-Mueller tube. CIDAS detectors are currently in

  1. Citing reports of alarm-related deaths, the Joint Commission issues a sentinel event alert for hospitals to improve medical device alarm safety.

    PubMed

    2013-06-01

    As medical devices become more widely used in hospitals, there is evidence that providers are becoming overwhelmed by the alarms that emanate from these machines. Experts link the problem with 566 alarm-related deaths reported in an FDA database between January 2005 and June 2010, and 80 alarm-related deaths reported in The Joint Commission's (TJC) own sentinel event database between January 2009 and June 2012. The ED is among the hospital sites where the adverse events reported to TJC most often occurred. Providers in some hospital units have to deal with thousands of alarm signals every day, and an estimated 85% to 95% of these alerts don't require any intervention, according to TJC. Experts say with so much noise and so many false alarms, clinicians can become desensitized to the medical-device alarms. The types of alarms that administrators should be most concerned about in the ED are dysrhythmia alarms on heart monitors, oxygen saturation alarms, and signals that a patient has a low respiratory rate. Experts urge hospitals to develop cross-disciplinary teams to address alarm safety on an ongoing basis, and to assemble action plans for improvement that contain baseline metrics that can be used to chart progress.

  2. 21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits....

  3. 21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits....

  4. 21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits....

  5. 21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits....

  6. 21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits....

  7. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20...) Automation alarms must be separate and independent of the following: (i) The fire detection and alarm...

  8. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20...) Automation alarms must be separate and independent of the following: (i) The fire detection and alarm...

  9. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20...) Automation alarms must be separate and independent of the following: (i) The fire detection and alarm...

  10. Chimpanzee Alarm Call Production Meets Key Criteria for Intentionality

    PubMed Central

    Schel, Anne Marijke; Townsend, Simon W.; Machanda, Zarin; Zuberbühler, Klaus; Slocombe, Katie E.

    2013-01-01

    Determining the intentionality of primate communication is critical to understanding the evolution of human language. Although intentional signalling has been claimed for some great ape gestural signals, comparable evidence is currently lacking for their vocal signals. We presented wild chimpanzees with a python model and found that two of three alarm call types exhibited characteristics previously used to argue for intentionality in gestural communication. These alarm calls were: (i) socially directed and given to the arrival of friends, (ii) associated with visual monitoring of the audience and gaze alternations, and (iii) goal directed, as calling only stopped when recipients were safe from the predator. Our results demonstrate that certain vocalisations of our closest living relatives qualify as intentional signals, in a directly comparable way to many great ape gestures. We conclude that our results undermine a central argument of gestural theories of language evolution and instead support a multimodal origin of human language. PMID:24146908

  11. 40 CFR 264.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operation must have immediate access to an internal alarm or emergency communication device, either directly... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Access to communications or alarm... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a)...

  12. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  13. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  14. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  15. 46 CFR 131.815 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire extinguishing alarm must be conspicuously marked:...

  16. 46 CFR 97.37-9 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 97.37-9 Section... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire extinguishing alarm must be conspicuously...

  17. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  18. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  19. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  20. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...