DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Karen S; Kasemir, Kay
2009-01-01
An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits.more » In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.« less
40 CFR 63.11527 - What are the monitoring requirements for new and existing sources?
Code of Federal Regulations, 2011 CFR
2011-07-01
... alarm that will sound when an increase in relative PM loadings is detected over the alarm set point... operating a bag leak detection system, if an alarm sounds, conduct visual monitoring of the monovent or... maintain a continuous parameter monitoring system (CPMS) to measure and record the 3-hour average pressure...
Mondor, Todd A; Finley, G Allen
2003-03-01
To examine the perceived urgency of 13 auditory warning alarms commonly occurring in the hospital operating room. Undergraduate students, who were naïve with respect to the clinical situation associated with the alarms, judged perceived urgency of each alarm on a ten-point scale. The perceived urgency of the alarms was not consistent with the actual urgency of the clinical situation that triggers it. In addition, those alarms indicating patient condition were generally perceived as less urgent than those alarms indicating the operation of equipment. Of particular interest were three sets of alarms designed by equipment manufacturers to indicate specific priorities for action. Listeners did not perceive any differences in the urgency of the 'information only', 'medium' and 'high' priority alarms of two of the monitors with all judged as low to moderate in urgency. In contrast, the high priority alarm of the third monitor was judged as significantly more urgent than its low and medium urgency counterparts. The alarms currently in use do not convey the intended sense of urgency to naïve listeners, and this holds even for two sets of alarms designed specifically by manufacturers to convey different levels of urgency.
40 CFR 1065.659 - Removed water correction.
Code of Federal Regulations, 2011 CFR
2011-07-01
... know that saturated water vapor conditions exist. Use good engineering judgment to measure the... absolute pressure based on an alarm set point, a pressure regulator set point, or good engineering judgment... from raw exhaust, you may determine the amount of water based on intake-air humidity, plus a chemical...
40 CFR 1065.659 - Removed water correction.
Code of Federal Regulations, 2010 CFR
2010-07-01
... know that saturated water vapor conditions exist. Use good engineering judgment to measure the... absolute pressure based on an alarm set point, a pressure regulator set point, or good engineering judgment... from raw exhaust, you may determine the amount of water based on intake-air humidity, plus a chemical...
Adjustable electronic load-alarm relay
Mason, Charles H.; Sitton, Roy S.
1976-01-01
This invention is an improved electronic alarm relay for monitoring the current drawn by an AC motor or other electrical load. The circuit is designed to measure the load with high accuracy and to have excellent alarm repeatability. Chattering and arcing of the relay contacts are minimal. The operator can adjust the set point easily and can re-set both the high and the low alarm points by means of one simple adjustment. The relay includes means for generating a signal voltage proportional to the motor current. In a preferred form of the invention a first operational amplifier is provided to generate a first constant reference voltage which is higher than a preselected value of the signal voltage. A second operational amplifier is provided to generate a second constant reference voltage which is lower than the aforementioned preselected value of the signal voltage. A circuit comprising a first resistor serially connected to a second resistor is connected across the outputs of the first and second amplifiers, and the junction of the two resistors is connected to the inverting terminal of the second amplifier. Means are provided to compare the aforementioned signal voltage with both the first and second reference voltages and to actuate an alarm if the signal voltage is higher than the first reference voltage or lower than the second reference voltage.
Atyeo, J; Sanderson, P M
2015-07-01
The melodic alarm sound set for medical electrical equipment that was recommended in the International Electrotechnical Commission's IEC 60601-1-8 standard has proven difficult for clinicians to learn and remember, especially clinicians with little prior formal music training. An alarm sound set proposed by Patterson and Edworthy in 1986 might improve performance for such participants. In this study, 31 critical and acute care nurses with less than one year of formal music training identified alarm sounds while they calculated drug dosages. Sixteen nurses used the IEC and 15 used the Patterson-Edworthy alarm sound set. The mean (SD) percentage of alarms correctly identified by nurses was 51.3 (25.6)% for the IEC alarm set and 72.1 (18.8)% for the Patterson-Edworthy alarms (p = 0.016). Nurses using the Patterson-Edworthy alarm sound set reported that it was easier to distinguish between alarm sounds than did nurses using the IEC alarm sound set (p = 0.015). Principles used to construct the Patterson-Edworthy alarm sounds should be adopted for future alarm sound sets. © 2015 The Association of Anaesthetists of Great Britain and Ireland.
Leandro, G; Rolando, N; Gallus, G; Rolles, K; Burroughs, A
2005-01-01
Background: Monitoring clinical interventions is an increasing requirement in current clinical practice. The standard CUSUM (cumulative sum) charts are used for this purpose. However, they are difficult to use in terms of identifying the point at which outcomes begin to be outside recommended limits. Objective: To assess the Bernoulli CUSUM chart that permits not only a 100% inspection rate, but also the setting of average expected outcomes, maximum deviations from these, and false positive rates for the alarm signal to trigger. Methods: As a working example this study used 674 consecutive first liver transplant recipients. The expected one year mortality set at 24% from the European Liver Transplant Registry average. A standard CUSUM was compared with Bernoulli CUSUM: the control value mortality was therefore 24%, maximum accepted mortality 30%, and average number of observations to signal was 500—that is, likelihood of false positive alarm was 1:500. Results: The standard CUSUM showed an initial descending curve (nadir at patient 215) then progressively ascended indicating better performance. The Bernoulli CUSUM gave three alarm signals initially, with easily recognised breaks in the curve. There were no alarms signals after patient 143 indicating satisfactory performance within the criteria set. Conclusions: The Bernoulli CUSUM is more easily interpretable graphically and is more suitable for monitoring outcomes than the standard CUSUM chart. It only requires three parameters to be set to monitor any clinical intervention: the average expected outcome, the maximum deviation from this, and the rate of false positive alarm triggers. PMID:16210461
The Recognizability and Localizability of Auditory Alarms: Setting Global Medical Device Standards.
Edworthy, Judy; Reid, Scott; McDougall, Siné; Edworthy, Jonathan; Hall, Stephanie; Bennett, Danielle; Khan, James; Pye, Ellen
2017-11-01
Objective Four sets of eight audible alarms matching the functions specified in IEC 60601-1-8 were designed using known principles from auditory cognition with the intention that they would be more recognizable and localizable than those currently specified in the standard. Background The audible alarms associated with IEC 60601-1-8, a global medical device standard, are known to be difficult to learn and retain, and there have been many calls to update them. There are known principles of design and cognition that might form the basis of more readily recognizable alarms. There is also scope for improvement in the localizability of the existing alarms. Method Four alternative sets of alarms matched to the functions specified in IEC 60601-1-8 were tested for recognizability and localizability and compared with the alarms currently specified in the standard. Results With a single exception, all prototype sets of alarms outperformed the current IEC set on both recognizability and localizability. Within the prototype sets, auditory icons were the most easily recognized, but the other sets, using word rhythms and simple acoustic metaphors, were also more easily recognized than the current alarms. With the exception of one set, all prototype sets were also easier to localize. Conclusion Known auditory cognition and perception principles were successfully applied to an existing audible alarm problem. Application This work constitutes the first (benchmarking) phase of replacing the alarms currently specified in the standard. The design principles used for each set demonstrate the relative ease with which different alarm types can be recognized and localized.
Lansdowne, Krystal; Strauss, David G; Scully, Christopher G
2016-01-01
The cacophony of alerts and alarms in a hospital produced by medical devices results in alarm fatigue. The pulse oximeter is one of the most common sources of alarms. One of the ways to reduce alarm rates is to adjust alarm settings at the bedside. This study is aimed to retrospectively examine individual pulse oximeter alarm settings on alarm rates and inter- and intra- patient variability. Nine hundred sixty-two previously collected intensive care unit (ICU) patient records were obtained from the Multiparameter Intelligent Monitoring in Intensive Care II Database (Beth Israel Deaconess Medical Center, Boston, MA). Inclusion criteria included patient records that contained SpO2 trend data sampled at 1 Hz for at least 1 h and a matching clinical record. SpO2 alarm rates were simulated by applying a range of thresholds (84, 86, 88, and 90 %) and delay times (10 to 60 s) to the SpO2 data. Patient records with at least 12 h of SpO2 data were examined for the variability in alarm rate over time. Decreasing SpO2 thresholds and increasing delay times resulted in decreased alarm rates. A limited number of patient records accounted for most alarms, and this number increased as alarm settings loosened (the top 10 % of patient records were responsible for 57.4 % of all alarms at an SpO2 threshold of 90 % and 15 s delay and 81.6 % at an SpO2 threshold of 84 % and 45 s delay). Alarm rates were not consistent over time for individual patients with periods of high and low alarms for all alarm settings. Pulse oximeter SpO2 alarm rates are variable between patients and over time, and the alarm rate and the extent of inter- and intra-patient variability can be affected by the alarm settings. Personalized alarm settings for a patient's current status may help to reduce alarm fatigue for nurses.
Christensen, Martin; Dodds, Andrew; Sauer, Josh; Watts, Nigel
2014-08-01
The aim of this survey was to assess registered nurse's perceptions of alarm setting and management in an Australian Regional Critical Care Unit. The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms. This study contributes to what is known about alarm fatigue, setting and management within a critical care environment. In addition it gives an insight as to what nurses' within a regional context consider the key factors which contribute to alarm fatigue. Clearly nursing burnout and potential patient harm are important considerations for practice especially when confronted with alarm fatigue and desensitisation. Therefore, promoting and maintaining an environment of ongoing intra-professional communication and alarm surveillance are crucial in alleviating these potential problems. Copyright © 2014. Published by Elsevier Ltd.
McGarraugh, Geoffrey
2010-01-01
Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG). Alarm evaluation in the Clinical and Laboratory Standards Institute (CLSI) guideline for CGM does not specifically address devices that employ both CGM and SMBG. In this report, an alarm evaluation method is proposed for these devices. The proposed method builds on the CLSI method using data from an in-clinic study of subjects with type 1 diabetes. CGM was used to detect glycemic events, and SMBG was used to determine treatment. To optimize detection of a single glucose level, such as 70 mg/dl, a range of alarm threshold settings was evaluated. The alarm characterization provides a choice of alarm settings that trade off detection and false alarms. Detection of a range of high glucose levels was similarly evaluated. Using low glucose alarms, detection of 70 mg/dl within 30 minutes increased from 64 to 97% as alarm settings increased from 70 to 100 mg/dl, and alarms that did not require treatment (SMBG >85 mg/dl) increased from 18 to 52%. Using high glucose alarms, detection of 180 mg/dl within 30 minutes increased from 87 to 96% as alarm settings decreased from 180 to 165 mg/dl, and alarms that did not require treatment (SMBG <180 mg/dl) increased from 24 to 42%. The proposed alarm evaluation method provides information for choosing appropriate alarm thresholds and reflects the clinical utility of CGM alarms. 2010 Diabetes Technology Society.
14 CFR 171.315 - Azimuth monitor system requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System... system must cause the radiation to cease and a warning must be provided at the designated control point... following procedure. The integral monitor alarm limit should be set to the angular equivalent of ±10 ft. at...
14 CFR 171.315 - Azimuth monitor system requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System... system must cause the radiation to cease and a warning must be provided at the designated control point... following procedure. The integral monitor alarm limit should be set to the angular equivalent of ±10 ft. at...
NASA Technical Reports Server (NTRS)
Stute, Robert A. (Inventor); Galloway, F. Houston (Inventor); Medelius, Pedro J. (Inventor); Swindle, Robert W. (Inventor); Bierman, Tracy A. (Inventor)
1996-01-01
A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.
Smart container UWB sensor system for situational awareness of intrusion alarms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romero, Carlos E.; Haugen, Peter C.; Zumstein, James M.
An in-container monitoring sensor system is based on an UWB radar intrusion detector positioned in a container and having a range gate set to the farthest wall of the container from the detector. Multipath reflections within the container make every point on or in the container appear to be at the range gate, allowing intrusion detection anywhere in the container. The system also includes other sensors to provide false alarm discrimination, and may include other sensors to monitor other parameters, e.g. radiation. The sensor system also includes a control subsystem for controlling system operation. Communications and information extraction capability maymore » also be included. A method of detecting intrusion into a container uses UWB radar, and may also include false alarm discrimination. A secure container has an UWB based monitoring system« less
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2013 CFR
2013-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2012 CFR
2012-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2011 CFR
2011-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2014 CFR
2014-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
29 CFR 1910.126 - Additional requirements for special dipping and coating operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sprinklers; or (ii) An automatic fire-extinguishing system conforming to the requirements of subpart L of... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...
29 CFR 1910.126 - Additional requirements for special dipping and coating operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operations from fire, you must have in place: (i) Automatic sprinklers; or (ii) An automatic fire... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...
29 CFR 1910.126 - Additional requirements for special dipping and coating operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operations from fire, you must have in place: (i) Automatic sprinklers; or (ii) An automatic fire... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...
29 CFR 1910.126 - Additional requirements for special dipping and coating operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sprinklers; or (ii) An automatic fire-extinguishing system conforming to the requirements of subpart L of... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...
Remote glucose monitoring in cAMP setting reduces the risk of prolonged nocturnal hypoglycemia.
DeSalvo, Daniel J; Keith-Hynes, Patrick; Peyser, Thomas; Place, Jérôme; Caswell, Kim; Wilson, Darrell M; Harris, Breanne; Clinton, Paula; Kovatchev, Boris; Buckingham, Bruce A
2014-01-01
This study tested the feasibility and effectiveness of remote continuous glucose monitoring (CGM) in a diabetes camp setting. Twenty campers (7-21 years old) with type 1 diabetes were enrolled at each of three camp sessions lasting 5-6 days. On alternating nights, 10 campers were randomized to usual wear of a Dexcom (San Diego, CA) G4™ PLATINUM CGM system, and 10 were randomized to remote monitoring with the Dexcom G4 PLATINUM communicating with the Diabetes Assistant, a cell phone platform, to allow wireless transmission of CGM values. Up to 15 individual graphs and sensor values could be displayed on a single remote monitor or portable tablet. An alarm was triggered for values <70 mg/dL, and treatment was given for meter-confirmed hypoglycemia. The primary end point was to decrease the duration of hypoglycemic episodes <50 mg/dL. There were 320 nights of CGM data and 197 hypoglycemic events. Of the remote monitoring alarms, 79% were true (meter reading of <70 mg/dL). With remote monitoring, 100% of alarms were responded to, whereas without remote monitoring only 54% of alarms were responded to. The median duration of hypoglycemic events <70 mg/dL was 35 min without remote monitoring and 30 min with remote monitoring (P=0.078). Remote monitoring significantly decreased prolonged hypoglycemic events, eliminating all events <50 mg/dL lasting longer than 30 min as well as all events <70 mg/dL lasting more than 2 h. Remote monitoring is feasible at diabetes camps and effective in reducing the risk of prolonged nocturnal hypoglycemia. This technology will facilitate forthcoming studies to evaluate the efficacy of automated closed-loop systems in the camp setting.
Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.
McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George
2016-07-01
The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.
Improved detection and false alarm rejection for chemical vapors using passive hyperspectral imaging
NASA Astrophysics Data System (ADS)
Marinelli, William J.; Miyashiro, Rex; Gittins, Christopher M.; Konno, Daisei; Chang, Shing; Farr, Matt; Perkins, Brad
2013-05-01
Two AIRIS sensors were tested at Dugway Proving Grounds against chemical agent vapor simulants. The primary objectives of the test were to: 1) assess performance of algorithm improvements designed to reduce false alarm rates with a special emphasis on solar effects, and 3) evaluate performance in target detection at 5 km. The tests included 66 total releases comprising alternating 120 kg glacial acetic acid (GAA) and 60 kg triethyl phosphate (TEP) events. The AIRIS sensors had common algorithms, detection thresholds, and sensor parameters. The sensors used the target set defined for the Joint Service Lightweight Chemical Agent Detector (JSLSCAD) with TEP substituted for GA and GAA substituted for VX. They were exercised at two sites located at either 3 km or 5 km from the release point. Data from the tests will be presented showing that: 1) excellent detection capability was obtained at both ranges with significantly shorter alarm times at 5 km, 2) inter-sensor comparison revealed very comparable performance, 3) false alarm rates < 1 incident per 10 hours running time over 143 hours of sensor operations were achieved, 4) algorithm improvements eliminated both solar and cloud false alarms. The algorithms enabling the improved false alarm rejection will be discussed. The sensor technology has recently been extended to address the problem of detection of liquid and solid chemical agents and toxic industrial chemical on surfaces. The phenomenology and applicability of passive infrared hyperspectral imaging to this problem will be discussed and demonstrated.
Physiologic Monitor Alarm Rates at 5 Children's Hospitals.
Schondelmeyer, Amanda C; Brady, Patrick W; Goel, Veena V; Cvach, Maria; Blake, Nancy; Mangeot, Colleen; Bonafide, Christopher P
2018-06-01
Alarm fatigue has been linked to patient morbidity and mortality in hospitals due to delayed or absent responses to monitor alarms. We sought to describe alarm rates at 5 freestanding children's hospitals during a single day and the types of alarms and proportions of patients monitored by using a point-prevalence, cross-sectional study design. We collected audible alarms on all inpatient units and calculated overall alarm rates and rates by alarm type per monitored patient per day. We found a total of 147,213 alarms during the study period, with 3-fold variation in alarm rates across hospitals among similar unit types. Across hospitals, onequarter of monitored beds were responsible for 71%, 61%, and 63% of alarms in medical-surgical, neonatal intensive care, and pediatric intensive care units, respectively. Future work focused on addressing nonactionable alarms in patients with the highest alarm counts may decrease alarm rates. © 2018 Society of Hospital Medicine.
Composing alarms: considering the musical aspects of auditory alarm design.
Gillard, Jessica; Schutz, Michael
2016-12-01
Short melodies are commonly linked to referents in jingles, ringtones, movie themes, and even auditory displays (i.e., sounds used in human-computer interactions). While melody associations can be quite effective, auditory alarms in medical devices are generally poorly learned and highly confused. Here, we draw on approaches and stimuli from both music cognition (melody recognition) and human factors (alarm design) to analyze the patterns of confusions in a paired-associate alarm-learning task involving both a standardized melodic alarm set (Experiment 1) and a set of novel melodies (Experiment 2). Although contour played a role in confusions (consistent with previous research), we observed several cases where melodies with similar contours were rarely confused - melodies holding musically distinctive features. This exploratory work suggests that salient features formed by an alarm's melodic structure (such as repeated notes, distinct contours, and easily recognizable intervals) can increase the likelihood of correct alarm identification. We conclude that the use of musical principles and features may help future efforts to improve the design of auditory alarms.
Hypoglycemia alarm enhancement using data fusion.
Skladnev, Victor N; Tarnavskii, Stanislav; McGregor, Thomas; Ghevondian, Nejhdeh; Gourlay, Steve; Jones, Timothy W
2010-01-01
The acceptance of closed-loop blood glucose (BG) control using continuous glucose monitoring systems (CGMS) is likely to improve with enhanced performance of their integral hypoglycemia alarms. This article presents an in silico analysis (based on clinical data) of a modeled CGMS alarm system with trained thresholds on type 1 diabetes mellitus (T1DM) patients that is augmented by sensor fusion from a prototype hypoglycemia alarm system (HypoMon). This prototype alarm system is based on largely independent autonomic nervous system (ANS) response features. Alarm performance was modeled using overnight BG profiles recorded previously on 98 T1DM volunteers. These data included the corresponding ANS response features detected by HypoMon (AiMedics Pty. Ltd.) systems. CGMS data and alarms were simulated by applying a probabilistic model to these overnight BG profiles. The probabilistic model developed used a mean response delay of 7.1 minutes, measurement error offsets on each sample of +/- standard deviation (SD) = 4.5 mg/dl (0.25 mmol/liter), and vertical shifts (calibration offsets) of +/- SD = 19.8 mg/dl (1.1 mmol/liter). Modeling produced 90 to 100 simulated measurements per patient. Alarm systems for all analyses were optimized on a training set of 46 patients and evaluated on the test set of 56 patients. The split between the sets was based on enrollment dates. Optimization was based on detection accuracy but not time to detection for these analyses. The contribution of this form of data fusion to hypoglycemia alarm performance was evaluated by comparing the performance of the trained CGMS and fused data algorithms on the test set under the same evaluation conditions. The simulated addition of HypoMon data produced an improvement in CGMS hypoglycemia alarm performance of 10% at equal specificity. Sensitivity improved from 87% (CGMS as stand-alone measurement) to 97% for the enhanced alarm system. Specificity was maintained constant at 85%. Positive predictive values on the test set improved from 61 to 66% with negative predictive values improving from 96 to 99%. These enhancements were stable within sensitivity analyses. Sensitivity analyses also suggested larger performance increases at lower CGMS alarm performance levels. Autonomic nervous system response features provide complementary information suitable for fusion with CGMS data to enhance nocturnal hypoglycemia alarms. 2010 Diabetes Technology Society.
Microprocessor-based multichannel flutter monitor using dynamic strain gage signals
NASA Technical Reports Server (NTRS)
Smalley, R. R.
1976-01-01
Two microprocessor-based multichannel monitors for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines were described. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs. frequency limit profiles. Each system design is described with details on design trade-offs, hardware, software, and operating experience.
Next-Generation Undersea Warfare and Undersea Distributed Networked Systems
2007-01-31
Probability of false alarm R5 Redeployment, refueling, repositioning, replacement, and recovery ROE Rules of engagement RSTA Reconnaissance, surveillance...and decision aids) at a given point, considering mission, tasks, rules of engagement (ROE), objectives, and other appropriate factors. " Manning within...trajectories are important and must occur concurrently; they must, however, be governed by different rule sets.21 II Mission Capability Centric .•UDNS
Functional relationship-based alarm processing
Corsberg, D.R.
1987-04-13
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). 11 figs.
Nishite, Yoshiaki; Takesawa, Shingo
2016-01-01
Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training.
Functional relationship-based alarm processing system
Corsberg, D.R.
1988-04-22
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary. 12 figs.
Functional relationship-based alarm processing
Corsberg, Daniel R.
1988-01-01
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously oupdated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on caussal factors between two alarms); (3) required action (system response or action) expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.
Functional relationship-based alarm processing system
Corsberg, Daniel R.
1989-01-01
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.
Classification Model for Forest Fire Hotspot Occurrences Prediction Using ANFIS Algorithm
NASA Astrophysics Data System (ADS)
Wijayanto, A. K.; Sani, O.; Kartika, N. D.; Herdiyeni, Y.
2017-01-01
This study proposed the application of data mining technique namely Adaptive Neuro-Fuzzy inference system (ANFIS) on forest fires hotspot data to develop classification models for hotspots occurrence in Central Kalimantan. Hotspot is a point that is indicated as the location of fires. In this study, hotspot distribution is categorized as true alarm and false alarm. ANFIS is a soft computing method in which a given inputoutput data set is expressed in a fuzzy inference system (FIS). The FIS implements a nonlinear mapping from its input space to the output space. The method of this study classified hotspots as target objects by correlating spatial attributes data using three folds in ANFIS algorithm to obtain the best model. The best result obtained from the 3rd fold provided low error for training (error = 0.0093676) and also low error testing result (error = 0.0093676). Attribute of distance to road is the most determining factor that influences the probability of true and false alarm where the level of human activities in this attribute is higher. This classification model can be used to develop early warning system of forest fire.
Berman, Mitchell F; Iyer, Nikhil; Freudzon, Leon; Wang, Shuang; Freundlich, Robert E; Housey, Michelle; Kheterpal, Sachin
2017-10-01
Continuous medication infusions are commonly used during surgical procedures. Alarm settings for infusion pumps are considered important for patient safety, but limits are not created in a standardized manner from actual usage data. We estimated 90th and 95th percentile infusion rates from a national database for potential use as upper limit alarm settings. We extracted infusion rate data from 17 major hospitals using intraoperative records provided by Multicenter Perioperative Outcomes Group for adult surgery between 2008 and 2014. Seven infusions were selected for study: propofol, remifentanil, dexmedetomidine, norepinephrine, phenylephrine, nitroglycerin, and esmolol. Each dosage entry for an infusion during a procedure was included. We estimated the 50th, 90th, and 95th percentile levels for each infusion across institutions, and performed quantile regression to examine factors that might affect the percentiles rates, such as use in general anesthesia versus sedation. The median 90th and 95th percentile infusion rates (with interquartile range) for propofol were 150 (140-150) and 170 (150-200) μg/kg/min. Quantile regression demonstrated higher 90th and 95th percentile rates during sedation for gastrointestinal endoscopy than for all surgical procedures performed under general anesthesia. For selected vasoactive medications, the corresponding median 90th and 95th percentile rates (with interquartile range) were norepinephrine 14.0 (9.8-18.1) and 18.3 (12.6-23.9) μg/min, and phenylephrine 60 (55-80) and 80 (75-100) μg/min. Alarm settings based on infusion rate percentile limits would be triggered at predictable rates; ie, the 95th percentile would be exceeded and an alarm sounded during 1 in 20 infusion rate entries. As a result, institutions could establish pump alarm settings consistent with desired alarm frequency using their own or externally validated usage data. Further study will be needed to determine the optimal percentile for infusion alarm settings.
Nishite, Yoshiaki; Takesawa, Shingo
2016-01-01
Background: Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. Objectives: The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. Materials and Methods: In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. Results: The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Conclusions: Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training. PMID:26981503
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2014 CFR
2014-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2013 CFR
2013-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2011 CFR
2011-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2012 CFR
2012-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
Joshi, Rohan; Mortel, Heidi van de; Feijs, Loe; Andriessen, Peter; Pul, Carola van
2017-01-01
Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient's room within the 90s of the alarm being generated. Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20-52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21-1.78; <0.001) while that of responding to a ventilator alarm was lower at 0.35 (95% CI = 0.27-0.46; p <0.001). For every 20s increase in the duration of an alarm, the odds of responding to the alarm (within 90s) increased to 1.15 (95% CI = 1.1-1.2; p <0.001). The random effect per infant improved the fit of the model to the data with the response times being slower for infants suffering from chronic illnesses while being faster for infants who were clinically unstable. Even though nurses respond to only a fraction of all critical alarms, they consider the vast majority of critical and yellow alarms as useful and relevant. When notified of a critical alarm, they seek waveform information and employ heuristics in determining whether or not to respond to the alarm. Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms.
van de Mortel, Heidi; Feijs, Loe; Andriessen, Peter; van Pul, Carola
2017-01-01
Aim Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. Methods The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient’s room within the 90s of the alarm being generated. Results Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20–52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21–1.78; <0.001) while that of responding to a ventilator alarm was lower at 0.35 (95% CI = 0.27–0.46; p <0.001). For every 20s increase in the duration of an alarm, the odds of responding to the alarm (within 90s) increased to 1.15 (95% CI = 1.1–1.2; p <0.001). The random effect per infant improved the fit of the model to the data with the response times being slower for infants suffering from chronic illnesses while being faster for infants who were clinically unstable. Discussion Even though nurses respond to only a fraction of all critical alarms, they consider the vast majority of critical and yellow alarms as useful and relevant. When notified of a critical alarm, they seek waveform information and employ heuristics in determining whether or not to respond to the alarm. Conclusion Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms. PMID:28981515
Perceptual evaluation of visual alerts in surveillance videos
NASA Astrophysics Data System (ADS)
Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun
2015-03-01
Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.
A novel algorithm for reducing false arrhythmia alarms in intensive care units.
Srivastava, Chandan; Sharma, Sonal; Jalali, Ali
2016-08-01
Alarm fatigue in intensive care units (ICU) is one of the top healthcare issues in the US. False alarms in ICU will decrease the quality of care and staff response time over the alarms. Normally, false alarm will cause desensitization of the clinical staff which leads to warnings and misleading, if the triggered alarm is true. In this study, we have proposed a multi-model ensemble approach to reduce the false alarm rate in monitoring systems. We have used 750 patient records from PhysioNet database. At First arrhythmia based features from electrocardiogram (ECG), arterial blood pressure (ABP) and photoplethysmogram (PPG) features were extracted from the records. Next, the dataset has been separated into two subsets on the basis of available features information. The first dataset (DS1) is the combination of ECG physiological, ABP and PPG features. Their correlation coefficient and p-values criteria have been applied for relevant alarm-wise feature-set selection, and random forest classifier was used for model development and validation. The threshold based approach was used on second dataset (DS2) which is the combination of arrhythmia, ABP and PPG features. The developed ensemble model is able to achieve sensitivity 83.33-100 % (average 95.56 %) being true alarms and suppress false alarms rate 66.67-89% (average 77.25%). The predictability of classifier shows the advantage to deal with unbalanced set of information, therefore overall model performance has reached to 83.96% accuracy.
Designing a SCADA system simulator for fast breeder reactor
NASA Astrophysics Data System (ADS)
Nugraha, E.; Abdullah, A. G.; Hakim, D. L.
2016-04-01
SCADA (Supervisory Control and Data Acquisition) system simulator is a Human Machine Interface-based software that is able to visualize the process of a plant. This study describes the results of the process of designing a SCADA system simulator that aims to facilitate the operator in monitoring, controlling, handling the alarm, accessing historical data and historical trend in Nuclear Power Plant (NPP) type Fast Breeder Reactor (FBR). This research used simulation to simulate NPP type FBR Kalpakkam in India. This simulator was developed using Wonderware Intouch software 10 and is equipped with main menu, plant overview, area graphics, control display, set point display, alarm system, real-time trending, historical trending and security system. This simulator can properly simulate the principle of energy flow and energy conversion process on NPP type FBR. This SCADA system simulator can be used as training media for NPP type FBR prospective operators.
Clinically relevant hypoglycemia prediction metrics for event mitigation.
Harvey, Rebecca A; Dassau, Eyal; Zisser, Howard C; Bevier, Wendy; Seborg, Dale E; Jovanovič, Lois; Doyle, Francis J
2012-08-01
The purpose of this study was to develop a method to compare hypoglycemia prediction algorithms and choose parameter settings for different applications, such as triggering insulin pump suspension or alerting for rescue carbohydrate treatment. Hypoglycemia prediction algorithms with different parameter settings were implemented on an ambulatory dataset containing 490 days from 30 subjects with type 1 diabetes mellitus using the Dexcom™ (San Diego, CA) SEVEN™ continuous glucose monitoring system. The performance was evaluated using a proposed set of metrics representing the true-positive ratio, false-positive rate, and distribution of warning times. A prospective, in silico study was performed to show the effect of using different parameter settings to prevent or rescue from hypoglycemia. The retrospective study results suggest the parameter settings for different methods of hypoglycemia mitigation. When rescue carbohydrates are used, a high true-positive ratio, a minimal false-positive rate, and alarms with short warning time are desired. These objectives were met with a 30-min prediction horizon and two successive flags required to alarm: 78% of events were detected with 3.0 false alarms/day and 66% probability of alarms occurring within 30 min of the event. This parameter setting selection was confirmed in silico: treating with rescue carbohydrates reduced the duration of hypoglycemia from 14.9% to 0.5%. However, for a different method, such as pump suspension, this parameter setting only reduced hypoglycemia to 8.7%, as can be expected by the low probability of alarming more than 30 min ahead. The proposed metrics allow direct comparison of hypoglycemia prediction algorithms and selection of parameter settings for different types of hypoglycemia mitigation, as shown in the prospective in silico study in which hypoglycemia was alerted or treated with rescue carbohydrates.
Yue, Liqing; Plummer, Virginia; Cross, Wendy
2017-09-01
To identify the effectiveness of education interventions provided for nurses for clinical alarm response and management. Some education has been undertaken to improve clinical alarm response, but the evidence for evaluating effectiveness for nurse education interventions is limited. Systematic review. A systematic review of experimental studies published in English from 2005-2015 was conducted in four computerised databases (MEDLINE, EMBASE, CINAHL and Scopus). After identification, screening and appraisal using Joanna Briggs Institute instruments, quality research papers were selected, data extraction and analysis followed. Five studies met the inclusion criteria for alarm response and no articles were concerned with clinical alarm education for management. All had different types and methods of interventions and statistical pooling was not possible. Response accuracy, response time and perceptions were consistent when different interventions were adopted. A positive effect was identified when learning about general alarms, single alarms, sequential alarms and medium-level alarms for learning as the primary task. Nurses who were musically trained had a faster and more accurate alarm response. Simulation interventions had a positive effect, but the effect of education provided in the care unit was greater. Overall, clinical alarm awareness was improved through education activities. Nurses are the main users of healthcare alarms and work in complex environments with high numbers of alarms, including nuisance alarms and other factors. Alarm-related adverse events are common. The findings of a small number of experimental studies with diverse evidence included consideration of various factors when formulating education strategies. The factors which influence effectiveness of nurse education are nurse demographics, nurse participants with musical training, workload and characteristics of alarms. Education interventions based in clinical practice settings increase education effectiveness, although simulation can be effective. No study shows any type of intervention results in sustained improvement. There are workload implications in education and the matching of load, number and type of alarms with nurse demographics which should be evaluated. There also needs to be a connection between education and the clinical setting to contribute to clinical alarm awareness for undergraduate nurses and practicing nurses. Education solely supported by employers is insufficient. Patient safety and long-term effects must be further explored. © 2016 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwantes, Jon M.; Douglas, Matthew; Morley, Shannon M.
[Participants will serve as border guards for Reimerland. They will be given brief instruction on the operation of hand-held RadioIsotope DetectorS (RIDS) and be provided an intelligence briefing that tells them to be on the lookout for suspicious activity at their post. Their instruction will include directing suspicious vehicles to a location for secondary screening. If, after secondary screening, suspicions of a criminal act involving nuclear and or radioactive materials remain, participants have been instructed to request assistance from the NLEA, who will then setup and manage a radiological crime scene. Participants will watch a demonstration of two vehicles containingmore » radioactive materials driving through and setting off a portal monitor. The first vehicle, a semi-tractor trailer, sets off only a gamma alarm. After the driver provides a shipping manifest of fertilizer, participants, posing as border guards, are expected to waive this vehicle through inspection. The second vehicle, an SUV, set off both gamma and 2 neutron alarms. The alarming of the neutron monitor should prompt participants to set up a secondary inspection of the vehicle immediately. The driver of the vehicle indicates he is in legal possession of an industrial instrument containing an old 133Ba source that has decayed to a level no longer requiring official paperwork according to the IAEA and internationally accepted transportation regulations. Authorities have verified that the industrial source does fit the description of one that is sold commercially. However, upon setting up a secondary screening, participants will use hand-held detectors to locate several other radioactive sources emanating from a black duffle bag in the rear of the vehicle (Figure 1). Hand held detectors detect the presence of 133Ba, and Pu. Upon questioning, the driver only commits to having the 133Ba industrial source and cannot account for the detection of neutrons within his vehicle. Since neutron alarms also sounded, participants should indicate that a neutron alarm would be inconsistent with a 133Ba source alone and should therefore conclude further investigation is warranted. This will prompt participants to call in a response team from the NLEA to set up a radiological crime scene around the vehicle in question. The response team is able to shoot a 3-D X-ray radiograph of the duffle bag without moving it to ensure it is rendered safe and moveable without disturbing the contents in the field (Figure 2). At this point, the duffle bag is entered into inventory as evidence and a chain of custody form is initiated. Swipes are taken from the outer bag to confirm there is no dispersible contamination. The bag and its contents are considered valuable for the investigation by the lead investigator. He determines the duffle bag is safe to transport to RRL for evidence inventory and analysis. The duffle bag and its contents are packaged and sent off to the RRL.]« less
Detection and quantification system for monitoring instruments
Dzenitis, John M [Danville, CA; Hertzog, Claudia K [Houston, TX; Makarewicz, Anthony J [Livermore, CA; Henderer, Bruce D [Livermore, CA; Riot, Vincent J [Oakland, CA
2008-08-12
A method of detecting real events by obtaining a set of recent signal results, calculating measures of the noise or variation based on the set of recent signal results, calculating an expected baseline value based on the set of recent signal results, determining sample deviation, calculating an allowable deviation by multiplying the sample deviation by a threshold factor, setting an alarm threshold from the baseline value plus or minus the allowable deviation, and determining whether the signal results exceed the alarm threshold.
Anomaly detection in forward looking infrared imaging using one-class classifiers
NASA Astrophysics Data System (ADS)
Popescu, Mihail; Stone, Kevin; Havens, Timothy; Ho, Dominic; Keller, James
2010-04-01
In this paper we describe a method for generating cues of possible abnormal objects present in the field of view of an infrared (IR) camera installed on a moving vehicle. The proposed method has two steps. In the first step, for each frame, we generate a set of possible points of interest using a corner detection algorithm. In the second step, the points related to the background are discarded from the point set using an one class classifier (OCC) trained on features extracted from a local neighborhood of each point. The advantage of using an OCC is that we do not need examples from the "abnormal object" class to train the classifier. Instead, OCC is trained using corner points from images known to be abnormal object free, i.e., that contain only background scenes. To further reduce the number of false alarms we use a temporal fusion procedure: a region has to be detected as "interesting" in m out of n, m
Fidler, Richard L; Pelter, Michele M; Drew, Barbara J; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J Matt; Hu, Xiao
2017-01-01
Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.
Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing
2016-08-01
False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2.
DiGuiseppi, Carolyn; Roberts, Ian; Wade, Angie; Sculpher, Mark; Edwards, Phil; Godward, Catherine; Pan, Huiqi; Slater, Suzanne
2002-01-01
Objective To measure the effect of giving out free smoke alarms on rates of fires and rates of fire related injury in a deprived multiethnic urban population. Design Cluster randomised controlled trial. Setting Forty electoral wards in two boroughs of inner London, United Kingdom. Participants Primarily households including elderly people or children and households that are in housing rented from the borough council. Intervention 20 050 smoke alarms, fittings, and educational brochures distributed free and installed on request. Main outcome measures Rates of fires and related injuries during two years after the distribution; alarm ownership, installation, and function. Results Giving out free smoke alarms did not reduce injuries related to fire (rate ratio 1.3; 95% confidence interval 0.9 to 1.9), admissions to hospital and deaths (1.3; 0.7 to 2.3), or fires attended by the fire brigade (1.1; 0.96 to 1.3). Similar proportions of intervention and control households had installed alarms (36/119 (30%) v 35/109 (32%); odds ratio 0.9; 95% confidence interval 0.5 to 1.7) and working alarms (19/118 (16%) v 18/108 (17%); 0.9; 0.4 to 1.8). Conclusions Giving out free smoke alarms in a deprived, multiethnic, urban community did not reduce injuries related to fire, mostly because few alarms had been installed or were maintained. What is already known on this topicIn the United Kingdom, residential fires caused 466 deaths and 14 600 non-fatal injuries in 1999The risk of death from fire is associated with socioeconomic classOne study reported an 80% decline in hospitalisations and deaths from residential fires after free smoke alarms were distributed in an area at high risk, but these results may not apply in other settings, and evidence from randomised controlled trials is lackingWhat this study addsGiving out free smoke alarms in a multiethnic poor urban population did not reduce injuries related to fire or firesGiving smoke alarms away may be a waste of resources and of little benefit unless alarm installation and maintenance is assured PMID:12411355
Understanding heart rate alarm adjustment in the intensive care units through an analytical approach
Pelter, Michele M.; Drew, Barbara J.; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J. Matt; Hu, Xiao
2017-01-01
Background Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. Objectives To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Methods Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). Results There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). Conclusions HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision. PMID:29176776
2012-07-01
cross track direction is calculated. This is accomplished by taking a 101 point horizontal slice of pixels centered on the alarm. Then, a 101 point...Hamming window, is the 101 -length row vector of FLGPR image pixels surrounding alarm A. We then store the first 50 frequency values (excluding the...Figure 3. Illustration of spectral features in the cross track direction and the difference between actual targets and FAs. Eleven rows of 101
Johnson, Kendall R; Hagadorn, James I; Sink, David W
2018-05-21
To reduce nonactionable oximeter alarms by 80% without increasing time infants were hypoxemic (oxygen saturation [SpO 2 ] ≤ 80%) or hyperoxemic (SpO 2 > 95% while on supplemental oxygen). In 2015, a multidisciplinary team at Connecticut Children's Medical Center initiated a quality improvement project to reduce nonactionable oximeter alarms in two referral neonatal intensive care units (NICUs). Changes made through improvement cycles included reduction of the low oximeter alarm limit for specific populations, increased low alarm delay, development of postmenstrual age-based alarm profiles, and updated bedside visual reminders. Manual alarm tallies and electronic SpO 2 data were collected throughout the project. Alarm tallies were collected for 158 patient care hours with SpO 2 data available for 138 of those hours. Mean number of total nonactionable alarms per patient per hour decreased from 9 to 2 (78% decrease) and the mean number of nonactionable low alarms per patient per hour decreased from 5 to 1 (80% decrease). No change was noted in the balancing measures of percentage time with SpO 2 ≤ 80% (mean 4.3%) or SpO 2 > 95% (mean 23.7%). Through small changes in oximeter alarm settings, including revision of alarm limits, alarm delays, and age-specific alarm profiles, our NICUs significantly reduced nonactionable alarms without increasing hypoxemia. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
[Research on early fire detection with CO-CO2 FTIR-spectroscopy].
Du, Jian-hua; Zhang, Ren-cheng; Huang, Xiang-ying; Gong, Xue; Zhang, Xiao-hua
2007-05-01
A new fire detection method is put forward based on the theory of FTIR spectroscopy through analyzing all kinds of detection methods, in which CO and CO2 are chosen as early fire detection objects, and an early fire experiment system has been set up. The concentration characters of CO and CO2 were obtained through early fire experiments including real alarm sources and nuisance alarm sources. In real alarm sources there are abundant CO and CO2 which change regularly. In nuisance alarm sources there is almost no CO. So it's feasible to reduce the false alarms and increase the sensitivity of early fire detectors through analyzing the concentration characters of CO and CO2.
ERIC Educational Resources Information Center
Mruzek, Daniel W.; McAleavey, Stephen; Engel, Suzanne; Smith, Tristram
2016-01-01
In this study, a novel enuresis alarm device using a miniaturized radio frequency module and disposable sensors made with inexpensive conductive ink was used to teach toilet use for urination with three participants with severe intellectual disability (two males and one female; aged 7-15 years) in a private special education school setting. At…
Reducing false asystole alarms in intensive care.
Dekimpe, Remi; Heldt, Thomas
2017-07-01
High rates of false monitoring alarms in intensive care can desensitize staff and therefore pose a significant risk to patient safety. Like other critical arrhythmia alarms, asystole alarms require immediate attention by the care providers as a true asystole event can be acutely life threatening. Here, it is illustrated that most false asystole alarms can be attributed to poor signal quality, and we propose and evaluate an algorithm to identify data windows of poor signal quality and thereby help suppress false asystole alarms. The algorithm combines intuitive signal-quality features (degree of signal saturation and baseline wander) and information from other physiological signals that might be available. Algorithm training and testing was performed on the MIMIC II and 2015 PhysioNet/Computing in Cardiology Challenge databases, respectively. The algorithm achieved an alarm specificity of 81.0% and sensitivity of 95.4%, missing only one out of 22 true asystole alarms. On a separate neonatal data set, the algorithm was able to reject 89.7% (890 out of 992) of false asystole alarms while keeping all 22 true events. The results show that the false asystole alarm rate can be significantly reduced through basic signal quality evaluation.
PT-SAFE: a software tool for development and annunciation of medical audible alarms.
Bennett, Christopher L; McNeer, Richard R
2012-03-01
Recent reports by The Joint Commission as well as the Anesthesia Patient Safety Foundation have indicated that medical audible alarm effectiveness needs to be improved. Several recent studies have explored various approaches to improving the audible alarms, motivating the authors to develop real-time software capable of comparing such alarms. We sought to devise software that would allow for the development of a variety of audible alarm designs that could also integrate into existing operating room equipment configurations. The software is meant to be used as a tool for alarm researchers to quickly evaluate novel alarm designs. A software tool was developed for the purpose of creating and annunciating audible alarms. The alarms consisted of annunciators that were mapped to vital sign data received from a patient monitor. An object-oriented approach to software design was used to create a tool that is flexible and modular at run-time, can annunciate wave-files from disk, and can be programmed with MATLAB by the user to create custom alarm algorithms. The software was tested in a simulated operating room to measure technical performance and to validate the time-to-annunciation against existing equipment alarms. The software tool showed efficacy in a simulated operating room environment by providing alarm annunciation in response to physiologic and ventilator signals generated by a human patient simulator, on average 6.2 seconds faster than existing equipment alarms. Performance analysis showed that the software was capable of supporting up to 15 audible alarms on a mid-grade laptop computer before audio dropouts occurred. These results suggest that this software tool provides a foundation for rapidly staging multiple audible alarm sets from the laboratory to a simulation environment for the purpose of evaluating novel alarm designs, thus producing valuable findings for medical audible alarm standardization.
System and method for statistically monitoring and analyzing sensed conditions
Pebay, Philippe P [Livermore, CA; Brandt, James M [Dublin, CA; Gentile, Ann C [Dublin, CA; Marzouk, Youssef M [Oakland, CA; Hale, Darrian J [San Jose, CA; Thompson, David C [Livermore, CA
2011-01-04
A system and method of monitoring and analyzing a plurality of attributes for an alarm condition is disclosed. The attributes are processed and/or unprocessed values of sensed conditions of a collection of a statistically significant number of statistically similar components subjected to varying environmental conditions. The attribute values are used to compute the normal behaviors of some of the attributes and also used to infer parameters of a set of models. Relative probabilities of some attribute values are then computed and used along with the set of models to determine whether an alarm condition is met. The alarm conditions are used to prevent or reduce the impact of impending failure.
System and method for statistically monitoring and analyzing sensed conditions
Pebay, Philippe P [Livermore, CA; Brandt, James M [Dublin, CA; Gentile, Ann C [Dublin, CA; Marzouk, Youssef M [Oakland, CA; Hale, Darrian J [San Jose, CA; Thompson, David C [Livermore, CA
2011-01-25
A system and method of monitoring and analyzing a plurality of attributes for an alarm condition is disclosed. The attributes are processed and/or unprocessed values of sensed conditions of a collection of a statistically significant number of statistically similar components subjected to varying environmental conditions. The attribute values are used to compute the normal behaviors of some of the attributes and also used to infer parameters of a set of models. Relative probabilities of some attribute values are then computed and used along with the set of models to determine whether an alarm condition is met. The alarm conditions are used to prevent or reduce the impact of impending failure.
System and method for statistically monitoring and analyzing sensed conditions
Pebay, Philippe P [Livermore, CA; Brandt, James M. , Gentile; Ann C. , Marzouk; Youssef M. , Hale; Darrian J. , Thompson; David, C [Livermore, CA
2010-07-13
A system and method of monitoring and analyzing a plurality of attributes for an alarm condition is disclosed. The attributes are processed and/or unprocessed values of sensed conditions of a collection of a statistically significant number of statistically similar components subjected to varying environmental conditions. The attribute values are used to compute the normal behaviors of some of the attributes and also used to infer parameters of a set of models. Relative probabilities of some attribute values are then computed and used along with the set of models to determine whether an alarm condition is met. The alarm conditions are used to prevent or reduce the impact of impending failure.
Carpenter, Tim E; Chrièl, Mariann; Greiner, Matthias
2007-01-16
Emergency preparedness relies on the ability to detect patterns in rare incidents in an early stage of an outbreak in order to implement relevant actions. Early warning of an abortion storm as a result of infection with a notifiable disease, e.g. brucellosis, bovine viral diarrhea (BVD) or infectious bovine rhinotracheitis (IBR), is a significant surveillance tool. This study used data from 507 large Danish dairy herds. A modified two-stage method for detecting an unusual increase in the abortion incidence was applied to the data. An alarm was considered true if an abortion were detected in the month following the alarm month, otherwise false. The total number of abortions that could potentially be avoided if effective action were taken ranged from 769 (22.9%) to 10 (0.3%), as the number of abortions required to set the alarm increased from 1 to 6. The vast majority of abortions could, however, not be predicted, much less prevented, given this early-warning system. The false to true alarm ratio was reduced when the number of abortions that set the alarm increased. The financial scenarios evaluated demonstrated that the value of an abortion, the cost of responding to an alarm and the efficiency of the actions are important for decision making when reporting an alarm. The presented model can readily be extended to other disease problems and multiple-time periods.
Design of remote car anti-theft system based on ZigBee
NASA Astrophysics Data System (ADS)
Fang, Hong; Yan, GangFeng; Li, Hong Lian
2015-12-01
A set of remote car anti-theft system based on ZigBee and GPRS with ARM11 built-in chip S3C6410 as the controller is designed. This system can detect the alarm information of the car with vibration sensor, pyroelectric sensor and infrared sensor. When the sensor detects any alarm signal, the ZigBee node in sleep will be awakened and then directly send the alarm signal to the microcontroller chip S3C6410 in the control room of the parking lot through ZigBee wireless transceiver module. After S3C6410 processes and analyzes the alarm signal, when any two sensors of the three collect the alarm signal, the LCD will display and generate an alarm and meanwhile it will send the alarm signal to the phone of the user in a wireless manner through the form of short message through GPRS module. Thus, the wireless remote monitoring of the system is realized.
A rule-based approach for the correlation of alarms to support Disaster and Emergency Management
NASA Astrophysics Data System (ADS)
Gloria, M.; Minei, G.; Lersi, V.; Pasquariello, D.; Monti, C.; Saitto, A.
2009-04-01
Key words: Simple Event Correlator, Agent Platform, Ontology, Semantic Web, Distributed Systems, Emergency Management The importance of recognition of emergency's typology to control the critical situation for security of citizens has been always recognized. It follows this aspect is very important for proper management of a hazardous event. In this work we present a solution for the recognition of emergency's typology adopted by an Italian research project, called CI6 (Centro Integrato per Servizi di Emergenza Innovativi). In our approach, CI6 receives alarms by citizen or people involved in the work (for example: police, operator of 112, and so on). CI6 represents any alarm by a set of information, including a text that describes it and obtained when the user points out the danger, and a pair of coordinates for its location. The system realizes an analysis of text and automatically infers information on the type of emergencies by means a set of parsing rules and rules of inference applied by a independent module: a correlator of events based on their log and called Simple Event Correlator (SEC). SEC, integrated in CI6's platform, is an open source and platform independent event correlation tool. SEC accepts input both files and text derived from standard input, making it flexible because it can be matched to any application that is able to write its output to a file stream. The SEC configuration is stored in text files as rules, each rule specifying an event matching condition, an action list, and optionally a Boolean expression whose truth value decides whether the rule can be applied at a given moment. SEC can produce output events by executing user-specified shell scripts or programs, by writing messages to files, and by various other means. SEC has been successfully applied in various domains like network management, system monitoring, data security, intrusion detection, log file monitoring and analysis, etc; it has been used or integrated with many application as CiscoWorks, HP OpenView NNM and Operation, BMC Patrol, etc. Analysis of text of an alarm can detect some keywords that allow to classify the particular event. The inference rules were developed by means an analysis about news regard real emergency found by web reaserches. We have seen that often a kind of emergency is characterized by more keyword. Keywords are not uniquely associated with a specific emergency, but they can be shared by different types of emergencies (such as. keyword "landslide" can be associated both emergency "landslide" and emergency "Flood"). However, the identification of two or more keywords associated with a particular type of emergency identified in most cases the correct type of emergency. So, for example, if text contains words as "water", "flood", "overflowing", "landslide" o other words belonging to the set of defined keywords or words that have some root of keywords, the system "decides" that this alarm belongs to specific typology, in this case "flood typology". The system has the memory of this information, so if a new alarm is reported and belongs to one of the typology already identified, it proceeds with the comparison of coordinates. The comparison between the centers of the alarms allows to see if they describe an area inscribed in an ideal circle that has centered on the first alarm and radius defined by the typology above mentioned. If this happens the system CI6 creates an emergency that has centered on the centre of that area and typology equal to that of the alarms. It follows that an emergency is represented by at least two alarms. Thus, the system suggests to manager (CI6's user) the possibility that most alarms can concern same events and makes a classification of this event. It is important to stress that CI6 is a system of decision support, hence also this service is limited to providing advice to the user to facilitate his task, leaving him the decision to accept it or not. REFERENCES SEC (Simple Event Correlator), http://kodu.neti.ee/~risto/sec/ M. Gloria,V. Lersi, G. Minei, D. Pasquariello, C. Monti, A. Saitto, "A Semantic WEB Services Platform to support Disaster and Emergency Management", 4th biennial Meeting of International Environmental Modelling and Software Society (iEMSs), 2008
Rowland, Diane; DiGuiseppi, Carolyn; Roberts, Ian; Curtis, Katherine; Roberts, Helen; Ginnelly, Laura; Sculpher, Mark; Wade, Angela
2002-01-01
Objectives To identify which type of smoke alarm is most likely to remain working in local authority inner city housing, and to identify an alarm tolerated in households with smokers. Design Randomised controlled trial. Setting Two local authority housing estates in inner London. Participants 2145 households. Intervention Installation of one of five types of smoke alarm (ionisation sensor with a zinc battery; ionisation sensor with a zinc battery and pause button; ionisation sensor with a lithium battery and pause button; optical sensor with a lithium battery; or optical sensor with a zinc battery). Main outcome measure Percentage of homes with any working alarm and percentage in which the alarm installed for this study was working after 15 months. Results 54.4% (1166/2145) of all households and 45.9% (465/1012) of households occupied by smokers had a working smoke alarm. Ionisation sensor, lithium battery, and there being a smoker in the household were independently associated with whether an alarm was working (adjusted odds ratios 2.24 (95% confidence interval 1.75 to 2.87), 2.20 (1.77 to 2.75), and 0.62 (0.52 to 0.74)). The most common reasons for non-function were missing battery (19%), missing alarm (17%), and battery disconnected (4%). Conclusions Nearly half of the alarms installed were not working when tested 15 months later. Type of alarm and power source are important determinants of whether a household had a working alarm. What is already known on this topicFunctioning smoke alarms can reduce the risk of death in the event of a house fireMany local authorities install smoke alarms in their propertiesSeveral different types of smoke alarm are availableWhat this study addsOnly half of the smoke alarms installed in local authority housing were still working 15 months laterIonising smoke alarms with long life lithium batteries were most likely to remain functioningInstalling smoke alarms may not be an effective use of resources PMID:12411356
Tarriela, Albert Fajardo; Gomez, Tiffany Michelle; Reed, Charles Calhoun; Rapp, Kami Marie
2015-01-01
Background Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step toward this requirement is identifying ICU nurses’ perceptions and common clinical practices toward clinical alarms, where little information is available. Objective Our aim was to determine perceptions and practices of transplant/cardiac ICU (TCICU) nurses toward clinical alarms and benchmark the results against the 2011 Healthcare Technology Foundation’s (HTF) Clinical Alarms Committee Survey. Methods A quality improvement project was conducted on a 20-bed TCICU with 39 full- and part-time nurses. Nurses were surveyed about their perceptions and attitudes toward and practices on clinical alarms using an adapted HTF clinical alarms survey. Results were compared to the 2011 HTF data. Correlations among variables were examined. Results All TCICU nurses provided usable responses (N=39, 100%). Almost all nurses (95%-98%) believed that false alarms are frequent, disrupt care, and reduce trust in alarm systems, causing nurses to inappropriately disable them. Unlike the 2011 HTF clinical alarms survey results, a significantly higher percentage of our TCICU nurses believed that existing devices are complex, questioned the ability and adequacy of the new monitoring systems to solve alarm management issues, pointed to the lack of prompt response to alarms, and indicated the lack of clinical policy on alarm management (P<.01). Major themes in the narrative data focused on nurses’ frustration related to the excessive number of alarms and poor usability of the cardiac monitors. A lack of standardized approaches exists in changing patients’ electrodes and individualizing parameters. Around 60% of nurses indicated they received insufficient training on bedside and central cardiac monitors. A correlation also showed the need for training on cardiac monitors, specifically for older nurses (P=.01). Conclusions False and non-actionable alarms continue to desensitize TCICU nurses, perhaps resulting in missing fatal alarms. Nurses’ attitudes and practices related to clinical alarms are key elements for designing contextually sensitive quality initiatives to fight alarm fatigue. Alarm management in ICUs is a multidimensional complex process involving usability of monitoring devices, and unit, clinicians, training, and policy-related factors. This indicates the need for a multi-method approach to decrease alarm fatigue and improve alarm systems safety. PMID:27025940
The application of machine vision in fire protection system
NASA Astrophysics Data System (ADS)
Rong, Jiang
2018-04-01
Based on the previous research, this paper introduces the theory of wavelet, collects the situation through the video system, and calculates the key information needed in the fire protection system. That is, through the algorithm to collect the information, according to the flame color characteristics and smoke characteristics were extracted, and as the characteristic information corresponding processing. Alarm system set the corresponding alarm threshold, when more than this alarm threshold, the system will alarm. This combination of flame color characteristics and smoke characteristics of the fire method not only improve the accuracy of judgment, but also improve the efficiency of judgments. Experiments show that the scheme is feasible.
Siebig, Sylvia; Kuhls, Silvia; Imhoff, Michael; Langgartner, Julia; Reng, Michael; Schölmerich, Jürgen; Gather, Ursula; Wrede, Christian E
2010-03-01
Monitoring of physiologic parameters in critically ill patients is currently performed by threshold alarm systems with high sensitivity but low specificity. As a consequence, a multitude of alarms are generated, leading to an impaired clinical value of these alarms due to reduced alertness of the intensive care unit (ICU) staff. To evaluate a new alarm procedure, we currently generate a database of physiologic data and clinical alarm annotations. Data collection is taking place at a 12-bed medical ICU. Patients with monitoring of at least heart rate, invasive arterial blood pressure, and oxygen saturation are included in the study. Numerical physiologic data at 1-second intervals, monitor alarms, and alarm settings are extracted from the surveillance network. Bedside video recordings are performed with network surveillance cameras. Based on the extracted data and the video recordings, alarms are clinically annotated by an experienced physician. The alarms are categorized according to their technical validity and clinical relevance by a taxonomy system that can be broadly applicable. Preliminary results showed that only 17% of the alarms were classified as relevant, and 44% were technically false. The presented system for collecting real-time bedside monitoring data in conjunction with video-assisted annotations of clinically relevant events is the first allowing the assessment of 24-hour periods and reduces the bias usually created by bedside observers in comparable studies. It constitutes the basis for the development and evaluation of "smart" alarm algorithms, which may help to reduce the number of alarms at the ICU, thereby improving patient safety. Copyright 2010 Elsevier Inc. All rights reserved.
Alarm pheromone is detected by the vomeronasal organ in male rats.
Kiyokawa, Yasushi; Kodama, Yuka; Kubota, Takahiro; Takeuchi, Yukari; Mori, Yuji
2013-10-01
It is widely known that a stressed animal releases specific pheromones, possibly for alarming nearby conspecifics. We previously investigated an alarm pheromone in male rats and found that this alarm pheromone evokes several responses, including increases in the defensive and risk assessment behaviors in a modified open-field test, and enhancement of the acoustic startle reflex. However, the role of the vomeronasal organ in these pheromone effects remains unclear. To clarify this point, vomeronasal organ-excising or sham surgeries were performed in male rats for use in 2 experimental models, after which they were exposed to alarm pheromone. We found that the vomeronasal organ-excising surgery blocked the effects of this alarm pheromone in both the modified open-field test and acoustic startle reflex test. In addition, the results of habituation/dishabituation test and soybean agglutinin binding to the accessory olfactory bulb suggested that the vomeronasal organ-excising surgery completely ablated the vomeronasal organ while preserving the functioning of the main olfactory system. From the above results, we showed that the vomeronasal organ plays an important role in alarm pheromone effects in the modified open-field test and acoustic startle reflex test.
Alali, Khaled; Casali, John G
2012-01-01
The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them more time to react to approaching vehicles. The results of this study suggest that as the attenuation of the hearing protectors increases, precautions should be considered by safety professionals. This is because, as it was the case with the Bilsom passive earmuff and E-A-R/3M Combat ArmsTM earplug-passive steady state, high attenuation minimizes the detection distance and as a result on-foot workers will have less time to react to any approaching vehicle. The main effects of the type of backup alarm signal demonstrated a statistically-significant advantage of the standard backup alarm over the broadband backup alarm on detection distance in feet. The magnitude of the improvement produced by the standard backup alarm was 221.5 feet, a very large margin. For example, with a vehicle backing at 10 mph, the 221.5 ft decrease in detection distance with the Brigade alarm equates to the vehicle arriving 15 seconds sooner at the worker from the point at which its alarm was first heard.
NASA Technical Reports Server (NTRS)
Dejesusparada, N. (Principal Investigator); Mattoso, S. D. Q.; Paradella, W. R.; Meneses, P. R.
1979-01-01
The author has identified the following significant results. Classification results point out 600 alarm areas of high potentiality of titanium occurrence. Almost 80 of these 600 alarm areas were checked by field work, and in 56 of them, titanium occurrences were confirmed and four new ore deposits were found.
Khan, Naveed; McClean, Sally; Zhang, Shuai; Nugent, Chris
2016-01-01
In recent years, smart phones with inbuilt sensors have become popular devices to facilitate activity recognition. The sensors capture a large amount of data, containing meaningful events, in a short period of time. The change points in this data are used to specify transitions to distinct events and can be used in various scenarios such as identifying change in a patient’s vital signs in the medical domain or requesting activity labels for generating real-world labeled activity datasets. Our work focuses on change-point detection to identify a transition from one activity to another. Within this paper, we extend our previous work on multivariate exponentially weighted moving average (MEWMA) algorithm by using a genetic algorithm (GA) to identify the optimal set of parameters for online change-point detection. The proposed technique finds the maximum accuracy and F_measure by optimizing the different parameters of the MEWMA, which subsequently identifies the exact location of the change point from an existing activity to a new one. Optimal parameter selection facilitates an algorithm to detect accurate change points and minimize false alarms. Results have been evaluated based on two real datasets of accelerometer data collected from a set of different activities from two users, with a high degree of accuracy from 99.4% to 99.8% and F_measure of up to 66.7%. PMID:27792177
Solvoll, Terje; Arntsen, Harald; Hartvigsen, Gunnar
2017-01-01
Surveys and research show that mobile communication systems in hospital settings are old and cause frequent interruptions. In the quest to remedy this, an Android based communication system called CallMeSmart tries to encapsulate most of the frequent communication into one hand held device focusing on reducing interruptions and at the same time make the workday easier for healthcare workers. The objective of CallMeSmart is to use context-awareness techniques to automatically monitor the availability of physicians' and nurses', and use this information to prevent or route phone calls, text messages, pages and alarms that would otherwise compromise patient care. In this paper, we present the results from interviewing nurses on alarm fatigue and their expectations regarding context-aware alarm handling using CallMeSmart.
NASA Astrophysics Data System (ADS)
Mu, Kai
2017-02-01
The established “Map World” on the National Geographic Information Public Service Platform offers free access to many geographic information in the Core Area of the Silk Road Economic Belt. Considering the special security situation and severe splittism and anti-splittism struggles in the Core Area of the Silk Road Economic Belt, a set of moving target positioning and alarming platform based on J2EE platform and B/S structure was designed and realized by combining the “Map World” data and global navigation satellite system. This platform solves various problems, such as effective combination of Global Navigation Satellite System (GNSS) and “Map World” resources, moving target alarming setting, inquiry of historical routes, system management, etc.
NASA Astrophysics Data System (ADS)
Marble, Jay A.; Gorman, John D.
1999-08-01
A feature based approach is taken to reduce the occurrence of false alarms in foliage penetrating, ultra-wideband, synthetic aperture radar data. A set of 'generic' features is defined based on target size, shape, and pixel intensity. A second set of features is defined that contains generic features combined with features based on scattering phenomenology. Each set is combined using a quadratic polynomial discriminant (QPD), and performance is characterized by generating a receiver operating characteristic (ROC) curve. Results show that the feature set containing phenomenological features improves performance against both broadside and end-on targets. Performance against end-on targets, however, is especially pronounced.
Organic Scintillation Detectors for Spectroscopic Radiation Portal Monitors
NASA Astrophysics Data System (ADS)
Paff, Marc Gerrit
Thousands of radiation portal monitors have been deployed worldwide to detect and deter the smuggling of nuclear and radiological materials that could be used in nefarious acts. Radiation portal monitors are often installed at bottlenecks where large amounts of people or goods must traverse. Examples of use include scanning cargo containers at shipping ports, vehicles at border crossings, and people at high profile functions and events. Traditional radiation portal monitors contain separate detectors for passively measuring neutron and gamma ray count rates. 3He tubes embedded in polyethylene and slabs of plastic scintillators are the most common detector materials used in radiation portal monitors. The radiation portal monitor alarm mechanism relies on measuring radiation count rates above user defined alarm thresholds. These alarm thresholds are set above natural background count rates. Minimizing false alarms caused by natural background and maximizing sensitivity to weakly emitting threat sources must be balanced when setting these alarm thresholds. Current radiation portal monitor designs suffer from frequent nuisance radiation alarms. These radiation nuisance alarms are most frequently caused by shipments of large quantities of naturally occurring radioactive material containing cargo, like kitty litter, as well as by humans who have recently undergone a nuclear medicine procedure, particularly 99mTc treatments. Current radiation portal monitors typically lack spectroscopic capabilities, so nuisance alarms must be screened out in time-intensive secondary inspections with handheld radiation detectors. Radiation portal monitors using organic liquid scintillation detectors were designed, built, and tested. A number of algorithms were developed to perform on-the-fly radionuclide identification of single and combination radiation sources moving past the portal monitor at speeds up to 2.2 m/s. The portal monitor designs were tested extensively with a variety of shielded and unshielded radiation sources, including special nuclear material, at the European Commission Joint Research Centre in Ispra, Italy. Common medical isotopes were measured at the C.S. Mott Children's Hospital and added to the radionuclide identification algorithms.
Multi-parameter vital sign database to assist in alarm optimization for general care units.
Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs
2016-12-01
Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.
Kobayashi, Leo; Gosbee, John W; Merck, Derek L
2017-07-01
(1) To develop a clinical microsystem simulation methodology for alarm fatigue research with a human factors engineering (HFE) assessment framework and (2) to explore its application to the comparative examination of different approaches to patient monitoring and provider notification. Problems with the design, implementation, and real-world use of patient monitoring systems result in alarm fatigue. A multidisciplinary team is developing an open-source tool kit to promote bedside informatics research and mitigate alarm fatigue. Simulation, HFE, and computer science experts created a novel simulation methodology to study alarm fatigue. Featuring multiple interconnected simulated patient scenarios with scripted timeline, "distractor" patient care tasks, and triggered true and false alarms, the methodology incorporated objective metrics to assess provider and system performance. Developed materials were implemented during institutional review board-approved study sessions that assessed and compared an experimental multiparametric alerting system with a standard monitor telemetry system for subject response, use characteristics, and end-user feedback. A four-patient simulation setup featuring objective metrics for participant task-related performance and response to alarms was developed along with accompanying structured HFE assessment (questionnaire and interview) for monitor systems use testing. Two pilot and four study sessions with individual nurse subjects elicited true alarm and false alarm responses (including diversion from assigned tasks) as well as nonresponses to true alarms. In-simulation observation and subject questionnaires were used to test the experimental system's approach to suppressing false alarms and alerting providers. A novel investigative methodology applied simulation and HFE techniques to replicate and study alarm fatigue in controlled settings for systems assessment and experimental research purposes.
Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C
2016-01-01
The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F(20,442) = 9.140, P < 0.001) and night (F(23,459) = 8.356, P < 0.001) alarm conditions compared to the respective control conditions. There was no difference in saliva cortisol between day alarm and day control conditions. Cortisol was higher (F(6,183) = 2.450, P < 0.001) following the night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F(6,174) = 4.071, P < 0.001) than the magnitude of difference between the day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants' ability to interpret the alarm when sleeping versus when awake.
Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C
2016-01-01
The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F20,442 = 9.140, P < 0.001) and night (F23,459 = 8.356, P < 0.001) alarm conditions compared to the respective control conditions. There was no difference in saliva cortisol between day alarm and day control conditions. Cortisol was higher (F6,183 = 2.450, P < 0.001) following the night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F6,174 = 4.071, P < 0.001) than the magnitude of difference between the day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants’ ability to interpret the alarm when sleeping versus when awake. PMID:27157688
A Time-Domain CMOS Oscillator-Based Thermostat with Digital Set-Point Programming
Chen, Chun-Chi; Lin, Shih-Hao
2013-01-01
This paper presents a time-domain CMOS oscillator-based thermostat with digital set-point programming [without a digital-to-analog converter (DAC) or external resistor] to achieve on-chip thermal management of modern VLSI systems. A time-domain delay-line-based thermostat with multiplexers (MUXs) was used to substantially reduce the power consumption and chip size, and can benefit from the performance enhancement due to the scaling down of fabrication processes. For further cost reduction and accuracy enhancement, this paper proposes a thermostat using two oscillators that are suitable for time-domain curvature compensation instead of longer linear delay lines. The final time comparison was achieved using a time comparator with a built-in custom hysteresis to generate the corresponding temperature alarm and control. The chip size of the circuit was reduced to 0.12 mm2 in a 0.35-μm TSMC CMOS process. The thermostat operates from 0 to 90 °C, and achieved a fine resolution better than 0.05 °C and an improved inaccuracy of ± 0.6 °C after two-point calibration for eight packaged chips. The power consumption was 30 μW at a sample rate of 10 samples/s. PMID:23385403
Proposed patient motion monitoring system using feature point tracking with a web camera.
Miura, Hideharu; Ozawa, Shuichi; Matsuura, Takaaki; Yamada, Kiyoshi; Nagata, Yasushi
2017-12-01
Patient motion monitoring systems play an important role in providing accurate treatment dose delivery. We propose a system that utilizes a web camera (frame rate up to 30 fps, maximum resolution of 640 × 480 pixels) and an in-house image processing software (developed using Microsoft Visual C++ and OpenCV). This system is simple to use and convenient to set up. The pyramidal Lucas-Kanade method was applied to calculate motions for each feature point by analysing two consecutive frames. The image processing software employs a color scheme where the defined feature points are blue under stable (no movement) conditions and turn red along with a warning message and an audio signal (beeping alarm) for large patient movements. The initial position of the marker was used by the program to determine the marker positions in all the frames. The software generates a text file that contains the calculated motion for each frame and saves it as a compressed audio video interleave (AVI) file. We proposed a patient motion monitoring system using a web camera, which is simple and convenient to set up, to increase the safety of treatment delivery.
Spering, C; Roessler, M; Kurlemann, T; Dresing, K; Stürmer, K M; Lehmann, W; Sehmisch, S
2017-12-12
The treatment of severely injured patients in the trauma resuscitation unit (TRU) requires an interdisciplinary and highly professional trauma team approach. The complete team needs to be waiting for the patient in the TRU on arrival. Treating severely injured patients in the TRU, the trauma team connects the initial preclinical emergency stabilization with the subsequent sophisticated treatment. Thus, the trauma team depends on concise information from the emergency personnel at the scene to provide its leader with further information as well as an accurate alarm including all departments necessary to stabilize the patient in the TRU. Aiming at an accurate and most efficient trauma team alarm, this study was designed to provide and analyze an alarm system which mobilizes the trauma team in a stepwise fashion depending on the pattern of injuries and the threat to life. The trauma team alarm system was analyzed in a prospective data acquisition at a level I trauma center over a period of 12 months. Evaluation followed the acquisition phase and provided comparison to the status prior to the establishment of the alarm system. All items underwent statistical testing using t‑tests (p < 0.05). The data of 775 TRU patients showed a significant reduction of false information on the patients status prior to arrival. It also showed an increase in punctual arrival in the TRU of the emergency teams. False alarms were significantly reduced (from 11.9% to 2.7%, p > 0.01). The duration from arrival of the patient in the TRU to the initial multislice computed tomography (CT) scan was reduced by 6 min while the total period of treatment in the TRU was reduced by 17 min. After the alarm system to gradually mobilize the trauma team was put into action, team members left the TRU if unneeded prior to finishing the initial treatment in only 4% of the cases. The patient fatality rate was 8.8% (injury severity score, ISS = 23 points) after establishment of the alarm system compared to 12.9% (ISS = 25 points) before. The implementation of an accurate and patient status-based alarm system to mobilize the trauma team can improve the quality of treatment while the duration of treatment of the severely injured patients in the TRU can be decreased. It also provides a most efficient mobilization of personnel resources while sustaining patient safety.
Multi-level scanning method for defect inspection
Bokor, Jeffrey; Jeong, Seongtae
2002-01-01
A method for performing scanned defect inspection of a collection of contiguous areas using a specified false-alarm-rate and capture-rate within an inspection system that has characteristic seek times between inspection locations. The multi-stage method involves setting an increased false-alarm-rate for a first stage of scanning, wherein subsequent stages of scanning inspect only the detected areas of probable defects at lowered values for the false-alarm-rate. For scanning inspection operations wherein the seek time and area uncertainty is favorable, the method can substantially increase inspection throughput.
Study of Threat Scenario Reconstruction based on Multiple Correlation
NASA Astrophysics Data System (ADS)
Yuan, Xuejun; Du, Jing; Qin, Futong; Zhou, Yunyan
2017-10-01
The emergence of intrusion detection technology has solved many network attack problems, ensuring the safety of computer systems. However, because of the isolated output alarm information, large amount of data, and mixed events, it is difficult for the managers to understand the deep logic relationship between the alarm information, thus they cannot deduce the attacker’s true intentions. This paper presents a method of online threat scene reconstruction to handle the alarm information, which reconstructs of the threat scene. For testing, the standard data set is used.
Ship cabin leakage alarm based on ARM SCM
NASA Astrophysics Data System (ADS)
Qu, Liyan
2018-03-01
If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.
Standardisation of radiation portal monitor controls and readouts.
Tinker, M
2010-10-01
There is an urgent need to standardise the numbering configuration of radiation portal monitor sensing panels. Currently, manufacturers use conflicting numbering schemes that may confuse operators of these varied systems. There is a similar problem encountered with the varied choices of coloured indicator lights and coloured print lines designated for gamma and neutron alarms. In addition, second-party software that changes the alarm colour scheme may also have been installed. Furthermore, no provision exists for the colour blind or to provide work stations with only black ink on alarm printouts. These inconsistencies and confusing set-ups could inadvertently cause a misinterpretation of the alarm, resulting in the potential release of a radiological hazard into a sovereign country. These issues are discussed, and a proposed solution is offered.
A description of nurses' decision-making in managing electrocardiographic monitor alarms.
Gazarian, Priscilla K; Carrier, Natalie; Cohen, Rachel; Schram, Haley; Shiromani, Samara
2015-01-01
To describe the cues and factors that nurses use in their decision-making when responding to clinical alarms. Alarms are designed to be very sensitive, and as a result, they are not very specific. Lack of adherence to the practice standards for electrocardiographic monitoring in hospital settings has been observed, resulting in overuse of the electrocardiographic monitoring. Monitoring without consideration of clinical indicators uses scarce healthcare resources and may even produce untoward circumstances because of alarm fatigue. With so many false alarms, alarm fatigue represents a symptom of a larger problem. It cannot be fixed until all of the factors that contribute to its existence have been examined. This was a qualitative descriptive study. This study was conducted at an academic medical centre located in the Northeast United States. Eight participants were enrolled using purposive sampling. Nurses were observed for two three-hour periods. Following each observation, the nurse was interviewed using the critical decision method to describe the cognitive processes related to the alarm activities. Qualitative data from the conducted interviews were analysed via an a priori framework founded in the critical decision method. This study reveals information, experience, guidance and decision-making as the four prominent categories contributing to nurses' decision-making in relation to alarm management. Managing technology was a category not identified a priori that emerged in the data analysis. Nurses revealed a breadth of information needed to adequately identify and interpret monitor alarms, and how they used that information to put the alarms into the particular context of an individual patient's situations. Understanding the cues and factors nurses use when responding to cardiac alarms will guide the development of learning experiences and inform policies to guide practice. © 2014 John Wiley & Sons Ltd.
User acceptance of intelligent avionics: A study of automatic-aided target recognition
NASA Technical Reports Server (NTRS)
Becker, Curtis A.; Hayes, Brian C.; Gorman, Patrick C.
1991-01-01
User acceptance of new support systems typically was evaluated after the systems were specified, designed, and built. The current study attempts to assess user acceptance of an Automatic-Aided Target Recognition (ATR) system using an emulation of such a proposed system. The detection accuracy and false alarm level of the ATR system were varied systematically, and subjects rated the tactical value of systems exhibiting different performance levels. Both detection accuracy and false alarm level affected the subjects' ratings. The data from two experiments suggest a cut-off point in ATR performance below which the subjects saw little tactical value in the system. An ATR system seems to have obvious tactical value only if it functions at a correct detection rate of 0.7 or better with a false alarm level of 0.167 false alarms per square degree or fewer.
Cowen, R.G.
1959-09-29
A description is given of electric protective systems and burglar alarm systems of the capacitance type in which the approach of an intruder at a place to be protected varies the capacitance in an electric circuit and the change is thereafter communicated to a remote point to actuate an alarm. According to the invention, an astable transitor multi-vibrator has the amplitude at its output voltage controlled by a change in the sensing capacitance. The sensing capacitance is effectively connected between collector and base of one stage of the multivibrator circuit through the detector-to-monitor line. The output of the detector is a small d-c voltage across the detector-to-monitor line. This d- c voltage is amplified and monitored at the other end of the line, where an appropriate alarm is actuated if a sudden change in the voltage occurs. The present system has a high degree of sensitivity and is very difficult to defeat by known techniques.
Robinson, Gene E.; Jakobsson, Eric
2016-01-01
The emerging field of sociogenomics explores the relations between social behavior and genome structure and function. An important question is the extent to which associations between social behavior and gene expression are conserved among the Metazoa. Prior experimental work in an invertebrate model of social behavior, the honey bee, revealed distinct brain gene expression patterns in African and European honey bees, and within European honey bees with different behavioral phenotypes. The present work is a computational study of these previous findings in which we analyze, by orthology determination, the extent to which genes that are socially regulated in honey bees are conserved across the Metazoa. We found that the differentially expressed gene sets associated with alarm pheromone response, the difference between old and young bees, and the colony influence on soldier bees, are enriched in widely conserved genes, indicating that these differences have genomic bases shared with many other metazoans. By contrast, the sets of differentially expressed genes associated with the differences between African and European forager and guard bees are depleted in widely conserved genes, indicating that the genomic basis for this social behavior is relatively specific to honey bees. For the alarm pheromone response gene set, we found a particularly high degree of conservation with mammals, even though the alarm pheromone itself is bee-specific. Gene Ontology identification of human orthologs to the strongly conserved honey bee genes associated with the alarm pheromone response shows overrepresentation of protein metabolism, regulation of protein complex formation, and protein folding, perhaps associated with remodeling of critical neural circuits in response to alarm pheromone. We hypothesize that such remodeling may be an adaptation of social animals to process and respond appropriately to the complex patterns of conspecific communication essential for social organization. PMID:27359102
Liu, Hui; Robinson, Gene E; Jakobsson, Eric
2016-06-01
The emerging field of sociogenomics explores the relations between social behavior and genome structure and function. An important question is the extent to which associations between social behavior and gene expression are conserved among the Metazoa. Prior experimental work in an invertebrate model of social behavior, the honey bee, revealed distinct brain gene expression patterns in African and European honey bees, and within European honey bees with different behavioral phenotypes. The present work is a computational study of these previous findings in which we analyze, by orthology determination, the extent to which genes that are socially regulated in honey bees are conserved across the Metazoa. We found that the differentially expressed gene sets associated with alarm pheromone response, the difference between old and young bees, and the colony influence on soldier bees, are enriched in widely conserved genes, indicating that these differences have genomic bases shared with many other metazoans. By contrast, the sets of differentially expressed genes associated with the differences between African and European forager and guard bees are depleted in widely conserved genes, indicating that the genomic basis for this social behavior is relatively specific to honey bees. For the alarm pheromone response gene set, we found a particularly high degree of conservation with mammals, even though the alarm pheromone itself is bee-specific. Gene Ontology identification of human orthologs to the strongly conserved honey bee genes associated with the alarm pheromone response shows overrepresentation of protein metabolism, regulation of protein complex formation, and protein folding, perhaps associated with remodeling of critical neural circuits in response to alarm pheromone. We hypothesize that such remodeling may be an adaptation of social animals to process and respond appropriately to the complex patterns of conspecific communication essential for social organization.
NASA Astrophysics Data System (ADS)
Moradi, Saed; Moallem, Payman; Sabahi, Mohamad Farzan
2018-03-01
False alarm rate and detection rate are still two contradictory metrics for infrared small target detection in an infrared search and track system (IRST), despite the development of new detection algorithms. In certain circumstances, not detecting true targets is more tolerable than detecting false items as true targets. Hence, considering background clutter and detector noise as the sources of the false alarm in an IRST system, in this paper, a false alarm aware methodology is presented to reduce false alarm rate while the detection rate remains undegraded. To this end, advantages and disadvantages of each detection algorithm are investigated and the sources of the false alarms are determined. Two target detection algorithms having independent false alarm sources are chosen in a way that the disadvantages of the one algorithm can be compensated by the advantages of the other one. In this work, multi-scale average absolute gray difference (AAGD) and Laplacian of point spread function (LoPSF) are utilized as the cornerstones of the desired algorithm of the proposed methodology. After presenting a conceptual model for the desired algorithm, it is implemented through the most straightforward mechanism. The desired algorithm effectively suppresses background clutter and eliminates detector noise. Also, since the input images are processed through just four different scales, the desired algorithm has good capability for real-time implementation. Simulation results in term of signal to clutter ratio and background suppression factor on real and simulated images prove the effectiveness and the performance of the proposed methodology. Since the desired algorithm was developed based on independent false alarm sources, our proposed methodology is expandable to any pair of detection algorithms which have different false alarm sources.
NASA Astrophysics Data System (ADS)
Franke, M.; Skolnik, D. A.; Harvey, D.; Lindquist, K.
2014-12-01
A novel and robust approach is presented that provides near real-time earthquake alarms for critical structures at distributed locations and large facilities using real-time estimation of response spectra obtained from near free-field motions. Influential studies dating back to the 1980s identified spectral response acceleration as a key ground motion characteristic that correlates well with observed damage in structures. Thus, monitoring and reporting on exceedance of spectra-based thresholds are useful tools for assessing the potential for damage to facilities or multi-structure campuses based on input ground motions only. With as little as one strong-motion station per site, this scalable approach can provide rapid alarms on the damage status of remote towns, critical infrastructure (e.g., hospitals, schools) and points of interests (e.g., bridges) for a very large number of locations enabling better rapid decision making during critical and difficult immediate post-earthquake response actions. Details on the novel approach are presented along with an example implementation for a large energy company. Real-time calculation of PSA exceedance and alarm dissemination are enabled with Bighorn, an extension module based on the Antelope software package that combines real-time spectral monitoring and alarm capabilities with a robust built-in web display server. Antelope is an environmental data collection software package from Boulder Real Time Technologies (BRTT) typically used for very large seismic networks and real-time seismic data analyses. The primary processing engine produces continuous time-dependent response spectra for incoming acceleration streams. It utilizes expanded floating-point data representations within object ring-buffer packets and waveform files in a relational database. This leads to a very fast method for computing response spectra for a large number of channels. A Python script evaluates these response spectra for exceedance of one or more specified spectral limits, reporting any such exceedances via alarm packets that are put in the object ring-buffer for use by any alarm processes that need them. The web-display subsystem allows alert dissemination, interactive exploration, and alarm cancellation via the WWW.
Perimeter intrusion alarm systems - May 1980 (Rev. 2)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-01-01
This guide describes six types of perimeter intrusion alarm systems and sets forth criteria for their performance and use as a means acceptable to the NRC staff for meeting specified portions of the Commission's regulations. It also references a document (SAND 76-0554) that provides additional information in this area, especially on the subject of combining sensors to yield a better overall performance.
Strategies for Managing Smart Pump Alarm and Alert Fatigue: A Narrative Review.
Shah, Parth K; Irizarry, Jamie; O'Neill, Sean
2018-06-08
Although smart infusion pumps are intended to prevent medication errors by alerting users about doses that exceed set thresholds, a large number of clinically insignificant alarms and alerts create the potential for alert and alarm fatigue. We searched the PubMed, Scopus, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases for peer-reviewed literature (January 1, 2004-August 31, 2017) on managing smart pump alerts, alarms, and related fatigue. Twenty-nine articles that met the inclusion criteria were reviewed and organized into themes. Smart pumps give users two types of signals: alarms that indicate mechanical issues such as occlusion, air in the line, or low battery; and clinical alerts that indicate that a programmed dose exceeds a predefined safety limit. Mechanical alarms occur with greater frequency than clinical alerts, but alarms and alerts vary widely by pump model, patient population, time of day, month, and type of drug. Several causes of clinically insignificant alerts and alarms may be actionable, and strategies proposed in the literature include development of a multidisciplinary team to oversee the quality improvement effort with involvement of end users, standardization of medication administration practices, widening of drug limit library thresholds when clinically appropriate, maintaining up-to-date drug limit libraries, and interoperability. Whereas many strategies have been proposed, and case studies have been reported, none have been rigorously evaluated. In addition, more research is needed related to managing occlusion and air-in-line alarms, especially for complicated infusions. Future work should focus on the evaluation of specific and replicable alert and alarm reduction strategies with a greater emphasis on quantitative metrics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Symposium on Toxic Substance Control: Decontamination, April 22 - 24, 1980, Columbus, Ohio.
1981-06-01
standard decontaminants is used. TABLE 1. Standard Chemical Decontaminants Decontaminant Agents Used On STB Blister and nerve agents DS-2 All chemical... agents M258 Kit Sodium Hydroxide, Ethanol, G-Series nerve agents Phenol, Water Chloramine B, ZnCI2, Blister ana V-Series Ethanol, Water nerve agents A...is a point source alarm that actively samples ambient air and reacts to low concentrations of nerve agents . The M-8 alarm detector also detects several
Sowan, Azizeh Khaled; Reed, Charles Calhoun; Staggers, Nancy
2016-09-30
Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. The audit log is a function of current capabilities of the physiologic monitoring systems, monitor's configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices' log capacity.
Use of the Cygnus GlucoWatch biographer at a diabetes camp.
Gandrud, Laura M; Paguntalan, Helen U; Van Wyhe, M Michelle; Kunselman, Betsy L; Leptien, Amy D; Wilson, Darrell M; Eastman, Richard C; Buckingham, Bruce A
2004-01-01
Detection and prevention of nocturnal hypoglycemia is a major medical concern at diabetes camps. We conducted an open-label trial of the Cygnus GlucoWatch biographer to detect nocturnal hypoglycemia in a diabetes camp, a nonclinical environment with multiple activities. Forty-five campers (7-17 years old) wore a biographer. The biographer was placed on the arm at 6:00 PM, with the low alarm set to 85 mg/dL (4.7 mmol/L). Overnight glucose monitoring occurred per usual camp protocol. Counselors were to check and record blood glucose values if the biographer alarmed. Biographers were worn for 154 nights by 45 campers. After a 3-hour warm-up period, 67% of biographers were calibrated, of which 28% were worn the entire night (12 hours). Thirty-four percent of readings were skipped because of: "data errors" (65%), sweat (20%), and temperature change (16%). Reported biographer values correlated with meter glucose values measured 11 to 20 minutes later (r = 0.90). Of 20 low-glucose alarms with corresponding meter values measured within 20 minutes, there were 10 true-positive alarms, 10 false-positive alarms, and no false-negative alarms. Campers reported sleep disruption 32% of the nights, and 74% found the biographer helpful. Campers reported they would wear the biographer 4 to 5 nights each week. Half of the biographer low-glucose alarms that had corresponding blood meter values were true-positive alarms, and the remaining were false-positive alarms. There was close correlation between the biographer and meter glucose values. The majority of campers found the biographer helpful and would use it at home.
NASA Astrophysics Data System (ADS)
Noh, Hae Young; Rajagopal, Ram; Kiremidjian, Anne S.
2012-04-01
This paper introduces a damage diagnosis algorithm for civil structures that uses a sequential change point detection method for the cases where the post-damage feature distribution is unknown a priori. This algorithm extracts features from structural vibration data using time-series analysis and then declares damage using the change point detection method. The change point detection method asymptotically minimizes detection delay for a given false alarm rate. The conventional method uses the known pre- and post-damage feature distributions to perform a sequential hypothesis test. In practice, however, the post-damage distribution is unlikely to be known a priori. Therefore, our algorithm estimates and updates this distribution as data are collected using the maximum likelihood and the Bayesian methods. We also applied an approximate method to reduce the computation load and memory requirement associated with the estimation. The algorithm is validated using multiple sets of simulated data and a set of experimental data collected from a four-story steel special moment-resisting frame. Our algorithm was able to estimate the post-damage distribution consistently and resulted in detection delays only a few seconds longer than the delays from the conventional method that assumes we know the post-damage feature distribution. We confirmed that the Bayesian method is particularly efficient in declaring damage with minimal memory requirement, but the maximum likelihood method provides an insightful heuristic approach.
An Electronic Worker Service System of the Pig House Based on ATmega16
NASA Astrophysics Data System (ADS)
Li, Liu-An; Jin, Tian-Ming; Yu, Ya-Ping; Zhang, Guo-Qiang; Hong, Tao
Pork is very important for people in daily life. Quality of livestock environment is closely related to the growth of animals. To improve environmental quality, the paper designed an electronic worker service system of the pig house based on ATmega16, which consisted of 6 detection modules, wireless data collecting, GSM, time circuit, display, anti-th alarm and music player, etc. A small LAN was constructed by wireless transceiver module to test and collect data of temperature, humidity and harmful gas concentration in the pig house. If one detection point exists that harmful pollutant gases concentration exceeds the standard value, GSM module took a message for livestock farmers, so that farmers can promptly arrive at the pig house to ventilate or deal with manure in the pig house, which can effectively prevent from bad things. Time of pyroelectric detector deployment can be freely set, and intrusion information was timely sent to the users. The anti-th alarm function was achieved by the auxiliary light. The music playing module is open by timer module in order to soothing pigs' life state. All are suitable for small farms and can save human resources.
Pressurized security barrier and alarm system
Carver, Don W.
1995-01-01
A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder's making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed.
Pressurized security barrier and alarm system
Carver, D.W.
1995-04-11
A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder`s making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed. 7 figures.
NASA Astrophysics Data System (ADS)
Zhang, Zaixuan; Wang, Kequan; Kim, Insoo S.; Wang, Jianfeng; Feng, Haiqi; Guo, Ning; Yu, Xiangdong; Zhou, Bangquan; Wu, Xiaobiao; Kim, Yohee
2000-05-01
The DOFTS system that has applied to temperature automatically alarm system of coal mine and tunnel has been researched. It is a real-time, on line and multi-point measurement system. The wavelength of LD is 1550 nm, on the 6 km optical fiber, 3000 points temperature signal is sampled and the spatial position is certain. Temperature measured region: -50 degree(s)C--100 degree(s)C; measured uncertain value: +/- 3 degree(s)C; temperature resolution: 0.1 degree(s)C; spatial resolution: <5 cm (optical fiber sensor probe); <8 m (spread optical fiber); measured time: <70 s. In the paper, the operated principles, underground test, test content and practical test results have been discussed.
Brooks, Robin; Thorpe, Richard; Wilson, John
2004-11-11
A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice.
Differential diagnosis of apneas in preterm infants.
Paul, Karel; Melichar, Jan; Miletín, Jan; Dittrichová, Jaroslava
2009-02-01
Clinically relevant apneas, which are common in preterm infants, may adversely affect later neuropsychological condition in this group of patients. Pharmacotherapy to stimulate respiratory functions may be unsuccessful. Polygraphic recording may help in the differential diagnosis of these clinically relevant events. Twenty-nine preterm neonates born before 36 weeks of gestational age were examined using polygraphic recording (respiration--two channels, perioral electromyography, oxygen saturation, heart rate, electroencephalography, electrocardiography, electrooculography). The examination was ordered by the attending physician after an unsuccessful treatment of apnea by Aminophylline, and it should contribute to the clarification of the causes of these events. In the course of the polygraphic examinations, altogether 63 episodes were recorded during which the pulse oximeter alarm signal was set off. In 42 cases, the alarm signal was set off in events during which SaO(2) fell below 85%. In the remaining 21 cases, the alarm signal was set off in episodes during which early bradycardia below 90/min occurred. The onset of apnea was very often associated with the phasic increase of the perioral electromyography and with electroencephalography arousal reaction. Because of suspicion that these apneas may be triggered by episodes of gastroesophageal reflux, the interruption of the Aminophylline treatment and setting up an antireflux regimen were recommended. These therapeutic measures had a positive effect: The frequency of alarm signals decreased within 48 h by a statistically significant 50%. In cases where the pharmacotherapy of apnea by stimulation of respiratory functions is not successful, differential diagnostic analysis should be performed. Polygraphy may contribute to the clarification of the causes underlying clinically relevant apneas in a view of newly described polygraphic signs. It is feasible to suspect, based on these signs, that gastroesophageal reflux is the cause for clinically significant apneas in that case.
Görges, Matthias; West, Nicholas C; Christopher, Nancy A; Koch, Jennifer L; Brodie, Sonia M; Lowlaavar, Nasim; Lauder, Gillian R; Ansermino, J Mark
2016-04-01
Respiratory depression in children receiving postoperative opioid infusions is a significant risk because of the interindividual variability in analgesic requirement. Detection of respiratory depression (or apnea) in these children may be improved with the introduction of automated acoustic respiratory rate (RR) monitoring. However, early detection of adverse events must be balanced with the risk of alarm fatigue. Our objective was to evaluate the use of acoustic RR monitoring in children receiving opioid infusions on a postsurgical ward and identify the causes of false alarm and optimal alarm thresholds. A video ethnographic study was performed using an observational, mixed methods approach. After surgery, an acoustic RR sensor was placed on the participant's neck and attached to a Rad87 monitor. The monitor was networked with paging for alarms. Vital signs data and paging notification logs were obtained from the central monitoring system. Webcam videos of the participant, infusion pump, and Rad87 monitor were recorded, stored on a secure server, and subsequently analyzed by 2 research nurses to identify the cause of the alarm, response, and effectiveness. Alarms occurring within a 90-second window were grouped into a single-alarm response opportunity. Data from 49 patients (30 females) with median age 14 (range, 4.4-18.8) years were analyzed. The 896 bedside vital sign threshold alarms resulted in 160 alarm response opportunities (44 low RR, 74 high RR, and 42 low SpO2). In 141 periods (88% of total), for which video was available, 65% of alarms were deemed effective (followed by an alarm-related action within 10 minutes). Nurses were the sole responders in 55% of effective alarms and the patient or parent in 20%. Episodes of desaturation (SpO2 < 90%) were observed in 9 patients: At the time of the SpO2 paging trigger, the RR was >10 bpm in 6 of 9 patients. Based on all RR samples observed, the default alarm thresholds, to serve as a starting point for each patient, would be a low RR of 6 (>10 years of age) and 10 (4-9 years of age). In this study, the use of RR monitoring did not improve the detection of respiratory depression. An RR threshold, which would have been predictive of desaturations, would have resulted in an unacceptably high false alarm rate. Future research using a combination of variables (e.g., SpO2 and RR), or the measurement of tidal volumes, may be needed to improve patient safety in the postoperative ward.
Children's response to a commercial back-up warning device.
Sapien, R E; Widman Roux, J; Fullerton-Gleason, L
2003-03-01
To determine preschool children's response to a commercial back-up warning alarm in a mock setting of an automobile backing up. Preschool parking lot in Albuquerque, New Mexico, USA. With subjects acting as their own controls, 33 preschoolers were asked to walk behind a stationary vehicle twice. The first time, the control, no warning sound was emitted from the vehicle. The second time, the vehicle was placed in reverse gear triggering an alarm. Children's responses were recorded by a hidden video camera. Avoidance behavior by the child was considered a positive response. Location and distance to where the response occurred was measured. Thirty three children, 38-61 months, were studied. None responded to the alarm with avoidance behavior but 18 looked toward the vehicle or hesitated in their gait. Although over half of the children acknowledged the warning alarm, the device did not elicit avoidance behavior. Mere acknowledgment of the warning device would not prevent injury.
Assessing the home fire safety of urban older adults: a case study.
Twyman, Stephanie; Fahey, Erin; Lehna, Carlee
2014-01-01
Older adults are at a higher risk for fatal house fire injury due to decreased mobility, chronic illness, and lack of smoke alarms. The purpose of this illustrative case study is to describe the home fire safety (HFS) status of an urban older adult who participated in a large study funded by the Federal Emergency Management Agency (FEMA). During a home visit with the participant, HFS data were collected from documents, observation, physical artifacts, reflective logs, and interviews. Numerous HFS hazards were identified including non-working smoke alarms, inadequate number and inappropriate placement of smoke alarms, lack of carbon monoxide (CO) alarms, inability to identify a home fire escape plan, hot water heater temperature set too high, and cooking hazards. Identification of HFS risk factors will assist in the development of educational materials that can be tailored to the older adult population to decrease their risk of fire-related injuries and death.
Predictive Modeling of Cardiac Ischemia
NASA Technical Reports Server (NTRS)
Anderson, Gary T.
1996-01-01
The goal of the Contextual Alarms Management System (CALMS) project is to develop sophisticated models to predict the onset of clinical cardiac ischemia before it occurs. The system will continuously monitor cardiac patients and set off an alarm when they appear about to suffer an ischemic episode. The models take as inputs information from patient history and combine it with continuously updated information extracted from blood pressure, oxygen saturation and ECG lines. Expert system, statistical, neural network and rough set methodologies are then used to forecast the onset of clinical ischemia before it transpires, thus allowing early intervention aimed at preventing morbid complications from occurring. The models will differ from previous attempts by including combinations of continuous and discrete inputs. A commercial medical instrumentation and software company has invested funds in the project with a goal of commercialization of the technology. The end product will be a system that analyzes physiologic parameters and produces an alarm when myocardial ischemia is present. If proven feasible, a CALMS-based system will be added to existing heart monitoring hardware.
NASA Astrophysics Data System (ADS)
Ackley, Kendall; Eikenberry, Stephen; Klimenko, Sergey; LIGO Team
2017-01-01
We present a false-alarm rate for a joint detection of gravitational wave (GW) events and associated electromagnetic (EM) counterparts for Advanced LIGO and Virgo (LV) observations during the first years of operation. Using simulated GW events and their recostructed probability skymaps, we tile over the error regions using sets of archival wide-field telescope survey images and recover the number of astrophysical transients to be expected during LV-EM followup. With the known GW event injection coordinates we inject artificial electromagnetic (EM) sources at that site based on theoretical and observational models on a one-to-one basis. We calculate the EM false-alarm probability using an unsupervised machine learning algorithm based on shapelet analysis which has shown to be a strong discriminator between astrophysical transients and image artifacts while reducing the set of transients to be manually vetted by five orders of magnitude. We also show the performance of our method in context with other machine-learned transient classification and reduction algorithms, showing comparability without the need for a large set of training data opening the possibility for next-generation telescopes to take advantage of this pipeline for LV-EM followup missions.
Design of the intelligent smoke alarm system based on photoelectric smoke
NASA Astrophysics Data System (ADS)
Ma, Jiangfei; Yang, Xiufang; Wang, Peipei
2017-02-01
This paper designed a kind of intelligent smoke alarm system based on photoelectric smoke detector and temperature, The system takes AT89C51 MCU as the core of hardware control and Labview as the host computer monitoring center.The sensor system acquires temperature signals and smoke signals, the MCU control A/D by Sampling and converting the output analog signals , and then the two signals will be uploaded to the host computer through the serial communication. To achieve real-time monitoring of smoke and temperature in the environment, LabVIEW monitoring platform need to hold, process, analysis and display these samping signals. The intelligent smoke alarm system is suitable for large scale shopping malls and other public places, which can greatly reduce the false alarm rate of fire, The experimental results show that the system runs well and can alarm when the setting threshold is reached,and the threshold parameters can be adjusted according to the actual conditions of the field. The system is easy to operate, simple in structure, intelligent, low cost, and with strong practical value.
Baxter, Gordon D; Monk, Andrew F; Tan, Kenneth; Dear, Peter R F; Newell, Simon J
2005-11-01
New medical systems may be rejected by staff because they do not integrate with local practice. An expert system, FLORENCE, is being developed to help staff in a neonatal intensive care unit (NICU) make decisions about ventilator settings when treating babies with respiratory distress syndrome. For FLORENCE to succeed it must be clinically useful and acceptable to staff in the context of local work practices. The aim of this work was to identify those contextual factors that would affect FLORENCE's success. A cognitive task analysis (CTA) of the NICU was performed. First, work context analysis was used to identify how work is performed in the NICU. Second, the critical decision method (CDM) was used to analyse how staff make decisions about changing the ventilator settings. Third, naturalistic observation of staff's use of the ventilator was performed. A. The work context analysis identified the NICU's hierarchical communication structure and the importance of numerous types of record in communication. B. It also identified important ergonomic and practical requirements for designing the displays and positioning the computer. C. The CDM interviews suggested instances where problems can arise if the data used by FLORENCE, which is automatically read, is not manually verified. D. Observation showed that most alarms cleared automatically. When FLORENCE raises an alarm, staff will normally be required to intervene and make a clinical judgement, even if the ventilator settings are not subsequently changed. FLORENCE must not undermine the NICU's hierarchical communication channels (A). The re-design of working practices to incorporate FLORENCE, reinforced through its user interface, must ensure that expert help is called on when appropriate (A). The procedures adopted with FLORENCE should ensure that the data the advice is based upon is valid (C). For example, FLORENCE could prompt staff to manually verify the data before implementing any suggested changes. FLORENCE's audible alarm should be clearly distinguishable from other NICU alarms (D); new procedures should be established to ensure that FLORENCE alarms receive attention (D), and false alarms from FLORENCE should be minimised (B, D). FLORENCE should always provide the data and reasoning underpinning its advice (A, C, D). The methods used in the CTA identified several contextual issues that could affect FLORENCE's acceptance. These issues, which extend beyond FLORENCE's capability to suggest changes to the ventilator settings, are being addressed in the design of the user interface and plans for FLORENCE's subsequent deployment.
A Signal Detection Theory Approach to Evaluating Oculometer Data Quality
NASA Technical Reports Server (NTRS)
Latorella, Kara; Lynn, William, III; Barry, John S.; Kelly, Lon; Shih, Ming-Yun
2013-01-01
Currently, data quality is described in terms of spatial and temporal accuracy and precision [Holmqvist et al. in press]. While this approach provides precise errors in pixels, or visual angle, often experiments are more concerned with whether subjects'points of gaze can be said to be reliable with respect to experimentally-relevant areas of interest. This paper proposes a method to characterize oculometer data quality using Signal Detection Theory (SDT) [Marcum 1947]. SDT classification results in four cases: Hit (correct report of a signal), Miss (failure to report a ), False Alarm (a signal falsely reported), Correct Reject (absence of a signal correctly reported). A technique is proposed where subjects' are directed to look at points in and outside of an AOI, and the resulting Points of Gaze (POG) are classified as Hits (points known to be internal to an AOI are classified as such), Misses (AOI points are not indicated as such), False Alarms (points external to AOIs are indicated as in the AOI), or Correct Rejects (points external to the AOI are indicated as such). SDT metrics describe performance in terms of discriminability, sensitivity, and specificity. This paper presentation will provide the procedure for conducting this assessment and an example of data collected for AOIs in a simulated flightdeck environment.
Continuous glucose monitoring: quality of hypoglycaemia detection.
Zijlstra, E; Heise, T; Nosek, L; Heinemann, L; Heckermann, S
2013-02-01
To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70 mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4 h and in case of a hypoglycaemic alarm. A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A + B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia. © 2012 Blackwell Publishing Ltd.
Lactic Acidosis in a Patient with Type 2 Diabetes Mellitus
2015-01-01
Lactic acidosis occurs when lactate production exceeds its metabolism. There are many possible causes of lactic acidosis, and in any given patient, several causes may coexist. This Attending Rounds presents a case in point. Metformin’s role in the pathogenesis of lactic acidosis in patients with diabetes mellitus is complex, as the present case illustrates. The treatment of lactic acidosis is controversial, except for the imperative to remedy its underlying cause. The use of sodium bicarbonate to treat the often alarming metabolic derangements may be quite efficacious in that regard but is of questionable benefit to patients. Renal replacement therapies (RRTs) have particular appeal in this setting for a variety of reasons, but their effect on clinical outcomes is untested. PMID:25762524
A pipeline leakage locating method based on the gradient descent algorithm
NASA Astrophysics Data System (ADS)
Li, Yulong; Yang, Fan; Ni, Na
2018-04-01
A pipeline leakage locating method based on the gradient descent algorithm is proposed in this paper. The method has low computing complexity, which is suitable for practical application. We have built experimental environment in real underground pipeline network. A lot of real data has been gathered in the past three months. Every leak point has been certificated by excavation. Results show that positioning error is within 0.4 meter. Rate of false alarm and missing alarm are both under 20%. The calculating time is not above 5 seconds.
Repetition increases false recollection in older people.
Pitarque, Alfonso; Sales, Alicia; Meléndez, Juan Carlos; Algarabel, Salvador
2015-02-01
Aging is accompanied by an increase in false alarms on recognition tasks, and these false alarms increase with repetition in older people (but not in young people). Traditionally, this increase was thought to be due to a greater use of familiarity in older people, but it was recently pointed out that false alarms also have a clear recollection component in these people. The main objective of our study is to analyze whether the expected increase in the rate of false alarms in older people due to stimulus repetition is produced by an inadequate use of familiarity, recollection, or both processes. To do so, we carried out an associative recognition experiment using pairs of words and pairs of images (faces associated with everyday contexts), in which we analyzed whether the repetition of some of the pairs increases the rate of false alarms in older people (compared to what was found in a sample of young people), and whether this increase is due to familiarity or recollection (using a remember-know paradigm). Our results show that the increase in false alarms in older people due to repetition is produced by false recollection, calling into question both dual and single-process models of recognition. Also, older people falsely recollect details of never studied stimuli, a clear case of perceptual illusions. These results are better explained in terms of source-monitoring errors, mediated by people's retrieval expectations. © 2014 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
McVey, Elaine; Keith, Steven; Herr, Joshua K.; Sutter, Diane; Pettis, Ronald J.
2015-01-01
Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjects received 4 of 8 infusion set combinations (ID: microneedle design A or B, with 2 pump brands [Animas or MiniMed]; SC: Teflon Quickset or steel Rapid-D, Animas pump only, with or without overtaping) and were evaluated for pump occlusion alarms, fluid leakage, pain, and tissue tolerability. A novel algorithm was developed to determine flow consistency based on fluid pressure, and the duration and occurrence rate for periods of unalarmed but interrupted flow (“silent occlusions’”) were compared. Results: ID delivery was successfully maintained over the 24-hour infusion period. The number of silent occlusions was lower for ID microneedle cannula design B than A (P < .01) and lower for Rapid-D SC device compared to Quick-set (P = .03). There was no significant difference in the number of occlusion alarms between the ID and SC devices with the Animas pump. However, the pumps tested with ID devices had significantly different alarm rates (MiniMed 29.5%, Animas 0%, P < .001). Leakage and tissue tolerability were comparable across devices. Conclusion: The ID infusion set reliably delivered diluent for an extended 24-hour period in healthy subjects and was well tolerated. Silent occlusion flow interruptions could be detected in both ID and SC infusion sets using a proprietary algorithm. This algorithm is a promising method for quantitatively evaluating infusion set flow performance. PMID:26319228
The double slit experiment and the time reversed fire alarm
NASA Astrophysics Data System (ADS)
Halabi, Tarek
2011-03-01
When both slits of the double slit experiment are open, closing one paradoxically increases the detection rate at some points on the detection screen. Feynman famously warned that temptation to "understand" such a puzzling feature only draws us into blind alleys. Nevertheless, we gain insight into this feature by drawing an analogy between the double slit experiment and a time reversed fire alarm. Much as closing the slit increases probability of a future detection, ruling out fire drill scenarios, having heard the fire alarm, increases probability of a past fire (using Bayesian inference). Classically, Bayesian inference is associated with computing probabilities of past events. We therefore identify this feature of the double slit experiment with a time reversed thermodynamic arrow. We believe that much of the enigma of quantum mechanics is simply due to some variation of time's arrow.
Design of DroDeASys (Drowsy Detection and Alarming System)
NASA Astrophysics Data System (ADS)
Juvale, Hrishikesh B.; Mahajan, Anant S.; Bhagwat, Ashwin A.; Badiger, Vishal T.; Bhutkar, Ganesh D.; Dhabe, Priyadarshan S.; Dhore, Manikrao L.
The paper discusses the Drowsy Detection & Alarming System that has been developed, using a non-intrusive approach. The system is basically developed to detect drivers dozing at the wheel at night time driving. The system uses a small infra-red night vision camera that points directly towards the driver`s face and monitors the driver`s eyes in order to detect fatigue. In such a case when fatigue is detected, a warning signal is issued to alert the driver. This paper discusses the algorithms that have been used to detect drowsiness. The decision whether the driver is dozing or not is taken depending on whether the eyes are open for a specific number of frames. If the eyes are found to be closed for a certain number of consecutive frames then the driver is alerted with an alarm.
A wireless sensor network deployment for rural and forest fire detection and verification.
Lloret, Jaime; Garcia, Miguel; Bri, Diana; Sendra, Sandra
2009-01-01
Forest and rural fires are one of the main causes of environmental degradation in Mediterranean countries. Existing fire detection systems only focus on detection, but not on the verification of the fire. However, almost all of them are just simulations, and very few implementations can be found. Besides, the systems in the literature lack scalability. In this paper we show all the steps followed to perform the design, research and development of a wireless multisensor network which mixes sensors with IP cameras in a wireless network in order to detect and verify fire in rural and forest areas of Spain. We have studied how many cameras, sensors and access points are needed to cover a rural or forest area, and the scalability of the system. We have developed a multisensor and when it detects a fire, it sends a sensor alarm through the wireless network to a central server. The central server selects the closest wireless cameras to the multisensor, based on a software application, which are rotated to the sensor that raised the alarm, and sends them a message in order to receive real-time images from the zone. The camera lets the fire fighters corroborate the existence of a fire and avoid false alarms. In this paper, we show the test performance given by a test bench formed by four wireless IP cameras in several situations and the energy consumed when they are transmitting. Moreover, we study the energy consumed by each device when the system is set up. The wireless sensor network could be connected to Internet through a gateway and the images of the cameras could be seen from any part of the world.
A Wireless Sensor Network Deployment for Rural and Forest Fire Detection and Verification
Lloret, Jaime; Garcia, Miguel; Bri, Diana; Sendra, Sandra
2009-01-01
Forest and rural fires are one of the main causes of environmental degradation in Mediterranean countries. Existing fire detection systems only focus on detection, but not on the verification of the fire. However, almost all of them are just simulations, and very few implementations can be found. Besides, the systems in the literature lack scalability. In this paper we show all the steps followed to perform the design, research and development of a wireless multisensor network which mixes sensors with IP cameras in a wireless network in order to detect and verify fire in rural and forest areas of Spain. We have studied how many cameras, sensors and access points are needed to cover a rural or forest area, and the scalability of the system. We have developed a multisensor and when it detects a fire, it sends a sensor alarm through the wireless network to a central server. The central server selects the closest wireless cameras to the multisensor, based on a software application, which are rotated to the sensor that raised the alarm, and sends them a message in order to receive real-time images from the zone. The camera lets the fire fighters corroborate the existence of a fire and avoid false alarms. In this paper, we show the test performance given by a test bench formed by four wireless IP cameras in several situations and the energy consumed when they are transmitting. Moreover, we study the energy consumed by each device when the system is set up. The wireless sensor network could be connected to Internet through a gateway and the images of the cameras could be seen from any part of the world. PMID:22291533
Design and development of a personal alarm monitor for use by first responders
NASA Astrophysics Data System (ADS)
Ehntholt, Daniel J.; Louie, Alan S.; Marenchic, Ingrid G.; Forni, Ronald J.
2004-03-01
This paper describes the design and development of a small, portable alarm device that can be used by first responders to an emergency event to warn of the presence of low levels of a toxic nerve gas. The device consists of a rigid reusable portion and a consumable packet that is sensitive to the presence of acetylcholinesterase inhibitors such as the nerve gases Sarin or Soman. The sensitivity level of the alarm is set to be at initial physiological response at the meiosis level, orders of magnitude below lethal concentrations. The AChE enzyme used is specific for nerve-type toxins. A color development reaction is used to demonstrate continued activity of the enzyme over its twelve-hour operational cycle.
Automated Information System (AIS) Alarm System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunteman, W.
1997-05-01
The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, themore » assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.« less
Sequential structural damage diagnosis algorithm using a change point detection method
NASA Astrophysics Data System (ADS)
Noh, H.; Rajagopal, R.; Kiremidjian, A. S.
2013-11-01
This paper introduces a damage diagnosis algorithm for civil structures that uses a sequential change point detection method. The general change point detection method uses the known pre- and post-damage feature distributions to perform a sequential hypothesis test. In practice, however, the post-damage distribution is unlikely to be known a priori, unless we are looking for a known specific type of damage. Therefore, we introduce an additional algorithm that estimates and updates this distribution as data are collected using the maximum likelihood and the Bayesian methods. We also applied an approximate method to reduce the computation load and memory requirement associated with the estimation. The algorithm is validated using a set of experimental data collected from a four-story steel special moment-resisting frame and multiple sets of simulated data. Various features of different dimensions have been explored, and the algorithm was able to identify damage, particularly when it uses multidimensional damage sensitive features and lower false alarm rates, with a known post-damage feature distribution. For unknown feature distribution cases, the post-damage distribution was consistently estimated and the detection delays were only a few time steps longer than the delays from the general method that assumes we know the post-damage feature distribution. We confirmed that the Bayesian method is particularly efficient in declaring damage with minimal memory requirement, but the maximum likelihood method provides an insightful heuristic approach.
Onsite Portable Alarm System - Its Merit and Application
NASA Astrophysics Data System (ADS)
Saita, J.; Sato, T.; Nakamura, Y.
2007-12-01
Recently an existence of the earthquake early warning system (EEWS) becomes popular. In general, the EEWS will be installed in a fixed observation site and it may consist of several separated components such as a sensing portion, A/D converter, an information processing potion and so on. The processed information for warning may be transmitted to network via fixed communication line, and therefore this kind of alarm system is called as Network Alarm System. On the other hand, after the severe earthquake damage, it is very important to save the disaster victims immediately. These rescue staffs are also under the risk of aftershocks and need a local alarm not depending on the network, so this kind of alarm can be called as Onsite Alarm. But the common early warning system is too complex to set onsite temporary, and even if possible to install, the alarm is too late to receive at the epicentral area. However, the new generation earthquake early warning system FREQL can issue the P wave alarm by minimum 0.2 seconds after P wave detection. And FREQL is characterized as the unique all-in-one seismometer with power unit. At the time of the 2004 Niigata-Ken-Chuetsu earthquake, a land slide attacked a car just passing. A hyper rescue team of Tokyo Fire Department pulled the survivor, one baby, from the land slide area. During their activity the rescue team was exposed to the risk of secondary hazards caused by the aftershocks. It was clear that it is necessary to use a portable warning system to issue the onsite P wave alarm. Because FREQL was originally developed as portable equipment, Tokyo Fire Department asked us to modify it to the portable equipment with the loud sound and the light signal. In this moment, this portable FREQL has equipped in nation wide. When the hyper rescue team of Tokyo Fire Department was sent to Pakistan as a task force for rescue work of the 2005 Pakistan earthquake, the portable FREQL was used as important onsite portable warning system and P wave alarms was actually issued by three times during the rescue work. Although this is one example for the actual application of portable onsite alarm, it is possible to apply the other field as the construction field. In this presentation, Portable Onsite Alarm is discussed from views of its necessity and application.
SeaQuest/E906 Shift Alarm System
NASA Astrophysics Data System (ADS)
Kitts, Noah
2014-09-01
SeaQuest, Fermilab E906, is a fixed target experiment that measures the Drell-Yan cross-section ratio of proton-proton to proton-deuterium collisions in order to extract the sea anti-quark structure of the proton. SeaQuest will extend the measurements made by E866/NuSea with greater precision at higher Bjorken-x. The continuously running experiment is always being monitored. Those on shift must keep track of all of the detector readouts in order to make sure the experiment is running correctly. As an experiment that is still in its early stages of running, an alarm system for people on shift is being created to provide warnings, such as a plot showing a detector's performance is sufficiently different to need attention. This plan involves python scripts that track live data. When the data shows a problem within the experiment, a corresponding alarm ID is sent to the MySQL database which then sets off an alarm. These alarms, which will alert the person on shift through both an audible and visual response, are important for ensuring that issues do not go unnoticed, and to help make sure the experiment is recording good data.
False recognition depends on depth of prior word processing: a magnetoencephalographic (MEG) study.
Walla, P; Hufnagl, B; Lindinger, G; Deecke, L; Imhof, H; Lang, W
2001-04-01
Brain activity was measured with a whole head magnetoencephalograph (MEG) during the test phases of word recognition experiments. Healthy young subjects had to discriminate between previously presented and new words. During prior study phases two different levels of word processing were provided according to two different kinds of instructions (shallow and deep encoding). Event-related fields (ERFs) associated with falsely recognized words (false alarms) were found to depend on the depth of processing during the prior study phase. False alarms elicited higher brain activity (as reflected by dipole strength) in case of prior deep encoding as compared to shallow encoding between 300 and 500 ms after stimulus onset at temporal brain areas. Between 500 and 700 ms we found evidence for differences in the involvement of neural structures related to both conditions of false alarms. Furthermore, the number of false alarms was found to depend on depth of processing. Shallow encoding led to a higher number of false alarms than deep encoding. All data are discussed as strong support for the ideas that a certain level of word processing is performed by a distinct set of neural systems and that the same neural systems which encode information are reactivated during the retrieval.
McGarraugh, Geoffrey; Bergenstal, Richard
2009-03-01
The objective of the analysis was to compare detection of hypoglycemic episodes (glucose <70 mg/dL lasting >15 min) with the FreeStyle Navigator Continuous Glucose Monitoring System (FSN-CGM) (Abbott Diabetes Care, Alameda, CA) alarms to detection with traditional finger stick testing at an average frequency of eight tests per day. The performance of FSN-CGM alarms was evaluated in a clinic setting using 58 subjects with type 1 diabetes mellitus (T1DM) monitoring interstitial glucose concentration over a 5-day period compared to reference YSI measurements (instrument manufactured by YSI, Yellow Springs, OH) at 15-min intervals. Finger stick glucose testing was evaluated in the home environment with 91 subjects with TIDM monitoring with the blood glucose meter integrated into the FreeStyle Navigator (FSN-BG) over a 20-day period. The reference was FSN-CGM with results masked from the subjects. Blood glucose values <=85 mg/dL were considered the optimal treatment level to avoid or reverse hypoglycemia. With a threshold alarm setting of 85 mg/dL, 90.6% of hypoglycemic episodes were detected within +/- 30 min by FSN-CGM in the clinic study. When the alarm was activated, YSI glucose was <= 85 mg/dL 77.2% of the time. In the home environment, the average FSN-BG testing frequency was 7.9 tests per day. Hypoglycemia was verified within +/- 30 min by FSN-BG measurements <= 85 mg/dL at a rate of 27.5%. Even with a high rate of FSN-BG testing, hypoglycemia detected by FSN-CGM was verified by patients with T1DM very infrequently. A high rate of hypoglycemia detection with a moderate rate of unnecessary alarms can be attained using FSN-CGM.
The potential benefit of a home fire safety intervention during emergency medical services calls.
Pirrallo, R G; Rubin, J M; Murawsky, G A
1998-03-01
To determine how often house fires occur at 1- and 2-family dwellings visited previously by emergency medical services (EMS) personnel and whether these visits were missed opportunities for a point-of-contact home fire safety intervention. A retrospective, consecutive, case series analysis of all Milwaukee Fire Department alarm responses during 1994 was performed. Measurements included date of service, type of response, property type, dollar loss estimate, number of injuries and fatalities, cause of alarm, and presence of an operational smoke detector. Descriptive, chi2, and relative risk statistics were used to describe the relationship between EMS responses and fire responses at 1- and 2-family dwellings. The Milwaukee Fire Department dispatched 94,378 requests for service to 43,556 addresses. 16,150 addresses generated multiple requests; 7.2% (1,162/16,150) were for an "alarm of fire" response [relative risk 1.83 (95% CI: 1.69-1.99) for addresses with multiple requests vs those with a single request for service]. Most [62% (721/1,162)] of the addresses were visited by EMS personnel prior to the alarm; 28% (205/721) were 1- and 2-family dwellings. A mean of 1.8 (376/205) EMS responses occurred prior to the "alarm of fire" response; 121 addresses received 1 response, 46 received 2, 18 received 3, and 20 received > or = 4 responses. Of 169 addresses with complete data, there was a total fire dollar loss of $1,963,020 (1994) along with 32 injuries and 0 fatalities. While 47% (80/169) of the 1- and 2-family dwellings had a smoke detector present, only 17% (29/169) of the dwellings had an operational smoke detector. A point-of-contact home fire safety intervention appears of potential benefit for frequent users of EMS care. Determination of the presence of an operational smoke detector in 1- and 2-family dwellings may be a useful injury prevention act during such EMS calls.
The impact of workload on the ability to localize audible alarms.
Edworthy, Judy; Reid, Scott; Peel, Katie; Lock, Samantha; Williams, Jessica; Newbury, Chloe; Foster, Joseph; Farrington, Martin
2018-10-01
Very little is known about people's ability to localize sound under varying workload conditions, though it would be expected that increasing workload should degrade performance. A set of eight auditory clinical alarms already known to have relatively high localizability (the ease with which their location is identified) when tested alone were tested in six conditions where workload was varied. Participants were required to indicate the location of a series of alarms emanating at random from one of eight speaker locations. Additionally, they were asked to read, carry out mental arithmetic tasks, be exposed to typical ICU noise, or carry out either the reading task or the mental arithmetic task in ICU noise. Performance in the localizability task was best in the control condition (no secondary task) and worst in those tasks which involved both a secondary task and noise. The data does therefore demonstrate the typical pattern of increasing workload affecting a primary task in an area where there is little data. In addition, the data demonstrates that performance in the control condition results in a missed alarm on one in ten occurrences, whereas performance in the heaviest workload conditions results in a missed alarm on every fourth occurrence. This finding has implications for the understanding of both 'inattentional deafness' and 'alarm fatigue' in clinical environments. Copyright © 2018 Elsevier Ltd. All rights reserved.
Detection of gas plumes in cluttered environments using long-wave infrared hyperspectral sensors
NASA Astrophysics Data System (ADS)
Broadwater, Joshua B.; Spisz, Thomas S.; Carr, Alison K.
2008-04-01
Long-wave infrared hyperspectral sensors provide the ability to detect gas plumes at stand-off distances. A number of detection algorithms have been developed for such applications, but in situations where the gas is released in a complex background and is at air temperature, these detectors can generate a considerable amount of false alarms. To make matters more difficult, the gas tends to have non-uniform concentrations throughout the plume making it spatially similar to the false alarms. Simple post-processing using median filters can remove a number of the false alarms, but at the cost of removing a significant amount of the gas plume as well. We approach the problem using an adaptive subpixel detector and morphological processing techniques. The adaptive subpixel detection algorithm is able to detect the gas plume against the complex background. We then use morphological processing techniques to isolate the gas plume while simultaneously rejecting nearly all false alarms. Results will be demonstrated on a set of ground-based long-wave infrared hyperspectral image sequences.
ISHM Decision Analysis Tool: Operations Concept
NASA Technical Reports Server (NTRS)
2006-01-01
The state-of-the-practice Shuttle caution and warning system warns the crew of conditions that may create a hazard to orbiter operations and/or crew. Depending on the severity of the alarm, the crew is alerted with a combination of sirens, tones, annunciator lights, or fault messages. The combination of anomalies (and hence alarms) indicates the problem. Even with much training, determining what problem a particular combination represents is not trivial. In many situations, an automated diagnosis system can help the crew more easily determine an underlying root cause. Due to limitations of diagnosis systems,however, it is not always possible to explain a set of alarms with a single root cause. Rather, the system generates a set of hypotheses that the crew can select from. The ISHM Decision Analysis Tool (IDAT) assists with this task. It presents the crew relevant information that could help them resolve the ambiguity of multiple root causes and determine a method for mitigating the problem. IDAT follows graphical user interface design guidelines and incorporates a decision analysis system. I describe both of these aspects.
Setting the Alarm: Word Emotional Attributes Require Consolidation to be Operational.
Dumay, Nicolas; Sharma, Dinkar; Kellen, Nora; Abdelrahim, Sarah
2018-01-25
Demonstrations of emotional Stroop in conditioned made-up words are flawed because of the lack of task ensuring similar word encoding across conditions. Here, participants were trained on associations between made-up words (e.g., 'drott') and pictures with an alarming or neutral content (e.g., 'a dead sheep' vs. 'a munching cow') in a situation that required attention to both ends of each association. To test whether word emotional attributes need to consolidate before they can hijack attention, one set of associations was learned seven days before the test, whereas the other set was learned either six hrs or immediately before the test. The novel words' ability to evoke their emotional attributes was assessed by using both Stroop and an auditory analogue called pause detection. Matching words and pictures was harder for alarming associations. However, similar learning rate and forgetting at seven days were observed for both types of associations. Pause detection revealed no emotion effect for same-day (i.e., unconsolidated) associations, but robust interference for seven-day-old (i.e., consolidated) alarming associations. Attention capture was found in the emotional Stroop as well, though only when trial n-1 referred to a same-day association. This task also showed stronger response repetition priming (independently of emotion) when trials n and n-1 both tapped into seven-day-old associations. Word emotional attributes hence take between six hrs and seven days to be operational. Moreover, age interactions between consecutive trials can be used to gauge implicitly the indirect (relational) episodic associations that develop in the meantime between the memories of individual items. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Gielen, Andrea C; Perry, Elise C; Shields, Wendy C; McDonald, Eileen; Frattaroli, Shannon; Jones, Vanya
2014-12-01
Door-to-door canvassing and installation of smoke alarms have been found to be effective at increasing the number of homes protected. This analysis reports on how smoke alarm coverage changes six months after a home visiting program in a large urban sample, and how this change varies by characteristics of the residents and characteristics of the services delivered during the home visit. Fire department Standard and Enhanced home visiting programs were compared. During the home visit, fire fighters installed lithium battery smoke alarms. Residents in the Enhanced program received tailored education about fire safety. Six months after the home visit, participating residences were visited to complete a follow-up survey and to have the installed alarms checked. 81% of the 672 homes that had a working smoke alarm on every level of the home at the end of the home visit remained safe at follow-up, and 87% of the residents found the home visit was very useful, and these rates did not differ between the Enhanced and Standard programs. The degree to which firefighters delivered their services varied, although households in which the resident's engagement with the fire department team was rated as excellent were 3.96 times as likely to be safe at follow-up compared to those with poor or fair resident engagement (p=0.03). There is a need to better understand how to maximize the time spent with residents during smoke alarm home visiting programs. This study helps with the development of methods needed for implementing and evaluating such programs in real-world settings.
Callan, Daniel E; Gateau, Thibault; Durantin, Gautier; Gonthier, Nicolas; Dehais, Frédéric
2018-06-01
Individuals often have reduced ability to hear alarms in real world situations (e.g., anesthesia monitoring, flying airplanes) when attention is focused on another task, sometimes with devastating consequences. This phenomenon is called inattentional deafness and usually occurs under critical high workload conditions. It is difficult to simulate the critical nature of these tasks in the laboratory. In this study, dry electroencephalography is used to investigate inattentional deafness in real flight while piloting an airplane. The pilots participating in the experiment responded to audio alarms while experiencing critical high workload situations. It was found that missed relative to detected alarms were marked by reduced stimulus evoked phase synchrony in theta and alpha frequencies (6-14 Hz) from 120 to 230 ms poststimulus onset. Correlation of alarm detection performance with intertrial coherence measures of neural phase synchrony showed different frequency and time ranges for detected and missed alarms. These results are consistent with selective attentional processes actively disrupting oscillatory coherence in sensory networks not involved with the primary task (piloting in this case) under critical high load conditions. This hypothesis is corroborated by analyses of flight parameters showing greater maneuvering associated with difficult phases of flight occurring during missed alarms. Our results suggest modulation of neural oscillation is a general mechanism of attention utilizing enhancement of phase synchrony to sharpen alarm perception during successful divided attention, and disruption of phase synchrony in brain networks when attentional demands of the primary task are great, such as in the case of inattentional deafness. © 2018 Wiley Periodicals, Inc.
Rossum, Huub H van; Kemperman, Hans
2017-07-26
General application of a moving average (MA) as continuous analytical quality control (QC) for routine chemistry assays has failed due to lack of a simple method that allows optimization of MAs. A new method was applied to optimize the MA for routine chemistry and was evaluated in daily practice as continuous analytical QC instrument. MA procedures were optimized using an MA bias detection simulation procedure. Optimization was graphically supported by bias detection curves. Next, all optimal MA procedures that contributed to the quality assurance were run for 100 consecutive days and MA alarms generated during working hours were investigated. Optimized MA procedures were applied for 24 chemistry assays. During this evaluation, 303,871 MA values and 76 MA alarms were generated. Of all alarms, 54 (71%) were generated during office hours. Of these, 41 were further investigated and were caused by ion selective electrode (ISE) failure (1), calibration failure not detected by QC due to improper QC settings (1), possible bias (significant difference with the other analyzer) (10), non-human materials analyzed (2), extreme result(s) of a single patient (2), pre-analytical error (1), no cause identified (20), and no conclusion possible (4). MA was implemented in daily practice as a continuous QC instrument for 24 routine chemistry assays. In our setup when an MA alarm required follow-up, a manageable number of MA alarms was generated that resulted in valuable MA alarms. For the management of MA alarms, several applications/requirements in the MA management software will simplify the use of MA procedures.
Design of indoor temperature and humidity detection system based on single chip microcomputer
NASA Astrophysics Data System (ADS)
Fu, Xiuwei; Fu, Li; Ma, Tianhui
2018-03-01
The indoor temperature and humidity detection system based on STC15F2K60S2 is designed in this paper. The temperature and humidity sensor DHT22 to monitor the indoor temperature and humidity are used, and the temperature and humidity data to the user's handheld device are wirelessly transmitted, when the temperature reaches or exceeds the user set the temperature alarm value, and the system sound and light alarm, to remind the user.
lidar change detection using building models
NASA Astrophysics Data System (ADS)
Kim, Angela M.; Runyon, Scott C.; Jalobeanu, Andre; Esterline, Chelsea H.; Kruse, Fred A.
2014-06-01
Terrestrial LiDAR scans of building models collected with a FARO Focus3D and a RIEGL VZ-400 were used to investigate point-to-point and model-to-model LiDAR change detection. LiDAR data were scaled, decimated, and georegistered to mimic real world airborne collects. Two physical building models were used to explore various aspects of the change detection process. The first model was a 1:250-scale representation of the Naval Postgraduate School campus in Monterey, CA, constructed from Lego blocks and scanned in a laboratory setting using both the FARO and RIEGL. The second model at 1:8-scale consisted of large cardboard boxes placed outdoors and scanned from rooftops of adjacent buildings using the RIEGL. A point-to-point change detection scheme was applied directly to the point-cloud datasets. In the model-to-model change detection scheme, changes were detected by comparing Digital Surface Models (DSMs). The use of physical models allowed analysis of effects of changes in scanner and scanning geometry, and performance of the change detection methods on different types of changes, including building collapse or subsistence, construction, and shifts in location. Results indicate that at low false-alarm rates, the point-to-point method slightly outperforms the model-to-model method. The point-to-point method is less sensitive to misregistration errors in the data. Best results are obtained when the baseline and change datasets are collected using the same LiDAR system and collection geometry.
Lactic Acidosis in a Patient with Type 2 Diabetes Mellitus.
Weisberg, Lawrence S
2015-08-07
Lactic acidosis occurs when lactate production exceeds its metabolism. There are many possible causes of lactic acidosis, and in any given patient, several causes may coexist. This Attending Rounds presents a case in point. Metformin's role in the pathogenesis of lactic acidosis in patients with diabetes mellitus is complex, as the present case illustrates. The treatment of lactic acidosis is controversial, except for the imperative to remedy its underlying cause. The use of sodium bicarbonate to treat the often alarming metabolic derangements may be quite efficacious in that regard but is of questionable benefit to patients. Renal replacement therapies (RRTs) have particular appeal in this setting for a variety of reasons, but their effect on clinical outcomes is untested. Copyright © 2015 by the American Society of Nephrology.
Combining Sense and Intelligence for Smart Structures
NASA Technical Reports Server (NTRS)
2002-01-01
IFOS developed the I*Sense technology with assistance from a NASA Langley Research Center SBIR contract. NASA and IFOS collaborated to create sensing network designs that have high sensitivity, low power consumption, and significant potential for mass production. The joint- research effort led to the development of a module that is rugged, compact and light-weight, and immune to electromagnetic interference. These features make the I*Sense multisensor arrays favorable for smart structure applications, including smart buildings, bridges, highways, dams, power plants, ships, and oil tankers, as well as space vehicles, space stations, and other space structures. For instance, the system can be used as an early warning and detection device, with alarms being set to monitor the maximum allowable strain and stress values at various points of a given structure.
ERIC Educational Resources Information Center
Biggs, Mary Jo Garcia; Simpson, Cynthia; Gaus, Mark D.
2010-01-01
The rate of bullying among individuals with disabilities is alarming. Because of the social and motor deficiencies that individuals with Asperger's syndrome (AS) often display, they are frequently targets of bullying. The physical education setting often consists of a larger number of students than the typical academic instructional setting. This…
Campus Facilities: A Diminishing Endowment.
ERIC Educational Resources Information Center
Rush, Sean; Johnson, Sandra
1990-01-01
Alarming findings were reported in a recent study of facility conditions. Two of the more common terms for describing the facilities problem are "capital renewal" and "deferred maintenance." How and why higher education reached this critical point is discussed. (MLW)
Hypoglycemia prediction with subject-specific recursive time-series models.
Eren-Oruklu, Meriyan; Cinar, Ali; Quinn, Lauretta
2010-01-01
Avoiding hypoglycemia while keeping glucose within the narrow normoglycemic range (70-120 mg/dl) is a major challenge for patients with type 1 diabetes. Continuous glucose monitors can provide hypoglycemic alarms when the measured glucose decreases below a threshold. However, a better approach is to provide an early alarm that predicts a hypoglycemic episode before it occurs, allowing enough time for the patient to take the necessary precaution to avoid hypoglycemia. We have previously proposed subject-specific recursive models for the prediction of future glucose concentrations and evaluated their prediction performance. In this work, our objective was to evaluate this algorithm further to predict hypoglycemia and provide early hypoglycemic alarms. Three different methods were proposed for alarm decision, where (A) absolute predicted glucose values, (B) cumulative-sum (CUSUM) control chart, and (C) exponentially weighted moving-average (EWMA) control chart were used. Each method was validated using data from the Diabetes Research in Children Network, which consist of measurements from a continuous glucose sensor during an insulin-induced hypoglycemia. Reference serum glucose measurements were used to determine the sensitivity to predict hypoglycemia and the false alarm rate. With the hypoglycemic threshold set to 60 mg/dl, sensitivity of 89, 87.5, and 89% and specificity of 67, 74, and 78% were reported for methods A, B, and C, respectively. Mean values for time to detection were 30 +/- 5.51 (A), 25.8 +/- 6.46 (B), and 27.7 +/- 5.32 (C) minutes. Compared to the absolute value method, both CUSUM and EWMA methods behaved more conservatively before raising an alarm (reduced time to detection), which significantly decreased the false alarm rate and increased the specificity. 2010 Diabetes Technology Society.
Real-Time Continuous Response Spectra Exceedance Calculation
NASA Astrophysics Data System (ADS)
Vernon, Frank; Harvey, Danny; Lindquist, Kent; Franke, Mathias
2017-04-01
A novel approach is presented for near real-time earthquake alarms for critical structures at distributed locations using real-time estimation of response spectra obtained from near free-field motions. Influential studies dating back to the 1980s identified spectral response acceleration as a key ground motion characteristic that correlates well with observed damage in structures. Thus, monitoring and reporting on exceedance of spectra-based thresholds are useful tools for assessing the potential for damage to facilities or multi-structure campuses based on input ground motions only. With as little as one strong-motion station per site, this scalable approach can provide rapid alarms on the damage status of remote towns, critical infrastructure (e.g., hospitals, schools) and points of interests (e.g., bridges) for a very large number of locations enabling better rapid decision making during critical and difficult immediate post-earthquake response actions. Real-time calculation of PSA exceedance and alarm dissemination are enabled with Bighorn, a module included in the Antelope software package that combines real-time spectral monitoring and alarm capabilities with a robust built-in web display server. Examples of response spectra from several M 5 events recorded by the ANZA seismic network in southern California will be presented.
Long-term monitoring of cardiorespiratory patterns in drug-resistant epilepsy.
Goldenholz, Daniel M; Kuhn, Amanda; Austermuehle, Alison; Bachler, Martin; Mayer, Christopher; Wassertheurer, Siegfried; Inati, Sara K; Theodore, William H
2017-01-01
Sudden unexplained death in epilepsy (SUDEP) during inpatient electroencephalography (EEG) monitoring has been a rare but potentially preventable event, with associated cardiopulmonary markers. To date, no systematic evaluation of alarm settings for a continuous pulse oximeter (SpO 2 ) has been performed. In addition, evaluation of the interrelationship between the ictal and interictal states for cardiopulmonary measures has not been reported. Patients with epilepsy were monitored using video-EEG, SpO 2 , and electrocardiography (ECG). Alarm thresholds were tested systematically, balancing the number of false alarms with true seizure detections. Additional cardiopulmonary patterns were explored using automated ECG analysis software. One hundred ninety-three seizures (32 generalized) were evaluated from 45 patients (7,104 h recorded). Alarm thresholds of 80-86% SpO 2 detected 63-73% of all generalized convulsions and 20-28% of all focal seizures (81-94% of generalized and 25-36% of focal seizures when considering only evaluable data). These same thresholds resulted in 25-146 min between false alarms. The sequential probability of ictal SpO 2 revealed a potential common seizure termination pathway of desaturation. A statistical model of corrected QT intervals (QTc), heart rate (HR), and SpO 2 revealed close cardiopulmonary coupling ictally. Joint probability maps of QTc and SpO 2 demonstrated that many patients had baseline dysfunction in either cardiac, pulmonary, or both domains, and that ictally there was dissociation-some patients exhibited further dysfunction in one or both domains. Optimal selection of continuous pulse oximetry thresholds involves a tradeoff between seizure detection accuracy and false alarm frequency. Alarming at 86% for patients that tend to have fewer false alarms and at 80% for those who have more, would likely result in a reasonable tradeoff. The cardiopulmonary findings may lead to SUDEP biomarkers and early seizure termination therapies. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.
Jose, Bipin; Lodha, Rakesh; Kabra, S K
2014-12-01
To compare the performance of two new generation pulse oximeters, one with enhanced signal extraction technology (SET) and other without enhanced SET in detecting hypoxemia and to correlate it with arterial blood gas analysis. Forty-eight patients, admitted to pediatric intensive care unit (PICU) of a teritiary care teaching hospital in India for critical care and support during the study period, who had an arterial catheter in situ were included. Children with those disease conditions known to interfere with pulse oximetry and blood gas analysis were excluded.184 set of observations were made during the study period. Each set had oxygen saturation (SpO2) measured from both the pulse oximeters and the corresponding arterial oxygen saturation (SaO2). The values were compared for occurrence of true and false alarms during periods of normal BP, hypotension and varying degrees of hypoxia. The mean arterial SaO2 in the study was 94.4 % ± 4.9. The mean SpO2 recorded in conventional and enhanced signal extraction technology (SET) pulse oximeters were 94.9 % ± 4.5 and 97.2 % ± 4.7 respectively. Enhanced signal extraction technology pulse oximeter detected 4/27 (15 %) of true hypoxemic events and 1 event was a false alarm. Conventional pulse oximeter detected 11/27 (41 %) true hypoxemic events but recorded 6 false alarms. Both pulse oximeters were not found to be performing satisfactorily in picking up hypoxemia in the study. There was good correlation with mean SpO2 from pulse oximeters and arterial SaO2. The reliability of pulse oximetry decreases with worsening hypoxemia and hypotension, and the sensitivity for picking up hypoxemia can be as low as 15 %.
NASA Astrophysics Data System (ADS)
Pignaton de Freitas, Edison; Heimfarth, Tales; Pereira, Carlos Eduardo; Morado Ferreira, Armando; Rech Wagner, Flávio; Larsson, Tony
2010-04-01
A current trend that is gaining strength in the wireless sensor network area is the use of heterogeneous sensor nodes in one coordinated overall network, needed to fulfill the requirements of sophisticated emerging applications, such as area surveillance systems. One of the main concerns when developing such sensor networks is how to provide coordination among the heterogeneous nodes, in order to enable them to efficiently respond the user needs. This study presents an investigation of strategies to coordinate a set of static sensor nodes on the ground cooperating with wirelessly connected Unmanned Aerial Vehicles (UAVs) carrying a variety of sensors, in order to provide efficient surveillance over an area of interest. The sensor nodes on the ground are set to issue alarms on the occurrence of a given event of interest, e.g. entrance of a non-authorized vehicle in the area, while the UAVs receive the issued alarms and have to decide which of them is the most suitable to handle the issued alarm. A bio-inspired coordination strategy based on the concept of pheromones is presented. As a complement of this strategy, a utility-based decision making approach is proposed.
2011-02-01
vacuum swing adsorption (VSA). This system would also be extremely quiet while operating. In applications where a pressurized air feed is available...review of the latest data set. 02 Apr 10, Friday - Status: OK. Tinker AFB reported a FAL alarm occurs when the compressor isn’t pumping oxygen. The...FAL alarm terminates when the compressor starts pumping oxygen. APCI/Ceramatec confirmed this occurrence is normal operation, however, it isn’t
Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang
2013-02-01
To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in incidence of barotraumas during CPR.
Understanding reliance on automation: effects of error type, error distribution, age and experience
Sanchez, Julian; Rogers, Wendy A.; Fisk, Arthur D.; Rovira, Ericka
2015-01-01
An obstacle detection task supported by “imperfect” automation was used with the goal of understanding the effects of automation error types and age on automation reliance. Sixty younger and sixty older adults interacted with a multi-task simulation of an agricultural vehicle (i.e. a virtual harvesting combine). The simulator included an obstacle detection task and a fully manual tracking task. A micro-level analysis provided insight into the way reliance patterns change over time. The results indicated that there are distinct patterns of reliance that develop as a function of error type. A prevalence of automation false alarms led participants to under-rely on the automation during alarm states while over relying on it during non-alarms states. Conversely, a prevalence of automation misses led participants to over-rely on automated alarms and under-rely on the automation during non-alarm states. Older adults adjusted their behavior according to the characteristics of the automation similarly to younger adults, although it took them longer to do so. The results of this study suggest the relationship between automation reliability and reliance depends on the prevalence of specific errors and on the state of the system. Understanding the effects of automation detection criterion settings on human-automation interaction can help designers of automated systems make predictions about human behavior and system performance as a function of the characteristics of the automation. PMID:25642142
Understanding reliance on automation: effects of error type, error distribution, age and experience.
Sanchez, Julian; Rogers, Wendy A; Fisk, Arthur D; Rovira, Ericka
2014-03-01
An obstacle detection task supported by "imperfect" automation was used with the goal of understanding the effects of automation error types and age on automation reliance. Sixty younger and sixty older adults interacted with a multi-task simulation of an agricultural vehicle (i.e. a virtual harvesting combine). The simulator included an obstacle detection task and a fully manual tracking task. A micro-level analysis provided insight into the way reliance patterns change over time. The results indicated that there are distinct patterns of reliance that develop as a function of error type. A prevalence of automation false alarms led participants to under-rely on the automation during alarm states while over relying on it during non-alarms states. Conversely, a prevalence of automation misses led participants to over-rely on automated alarms and under-rely on the automation during non-alarm states. Older adults adjusted their behavior according to the characteristics of the automation similarly to younger adults, although it took them longer to do so. The results of this study suggest the relationship between automation reliability and reliance depends on the prevalence of specific errors and on the state of the system. Understanding the effects of automation detection criterion settings on human-automation interaction can help designers of automated systems make predictions about human behavior and system performance as a function of the characteristics of the automation.
Data-based Considerations in Portal Radiation Monitoring of Cargo Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weier, Dennis R.; O'Brien, Robert F.; Ely, James H.
2004-07-01
Radiation portal monitoring of cargo vehicles often includes a configuration of four-panel monitors that record gamma and neutron counts from vehicles transporting cargo. As vehicles pass the portal monitors, they generate a count profile over time that can be compared to the average panel background counts obtained just prior to the time the vehicle entered the area of the monitors. Pacific Northwest National Laboratory has accumulated considerable data regarding such background radiation and vehicle profiles from portal installations, as well as in experimental settings using known sources and cargos. Several considerations have a bearing on how alarm thresholds are setmore » in order to maintain sensitivity to radioactive sources while also controlling to a manageable level the rate of false or nuisance alarms. False alarms are statistical anomalies while nuisance alarms occur due to the presence of naturally occurring radioactive material (NORM) in cargo, for example, kitty litter. Considerations to be discussed include: • Background radiation suppression due to the shadow shielding from the vehicle. • The impact of the relative placement of the four panels on alarm decision criteria. • Use of plastic scintillators to separate gamma counts into energy windows. • The utility of using ratio criteria for the energy window counts rather than simply using total window counts. • Detection likelihood for these various decision criteria based on computer simulated injections of sources into vehicle profiles.« less
Taking medicine at home - create a routine
... page: //medlineplus.gov/ency/patientinstructions/000613.htm Taking medicine at home - create a routine To use the ... teeth. Find Ways to Help You Remember Your Medicines You can: Set the alarm on your clock, ...
Sequential CFAR detectors using a dead-zone limiter
NASA Astrophysics Data System (ADS)
Tantaratana, Sawasd
1990-09-01
The performances of some proposed sequential constant-false-alarm-rate (CFAR) detectors are evaluated. The observations are passed through a dead-zone limiter, the output of which is -1, 0, or +1, depending on whether the input is less than -c, between -c and c, or greater than c, where c is a constant. The test statistic is the sum of the outputs. The test is performed on a reduced set of data (those with absolute value larger than c), with the test statistic being the sum of the signs of the reduced set of data. Both constant and linear boundaries are considered. Numerical results show a significant reduction of the average number of observations needed to achieve the same false alarm and detection probabilities as a fixed-sample-size CFAR detector using the same kind of test statistic.
Maximino, Caio; Lima, Monica Gomes; Costa, Carina Cardoso; Guedes, Iêda Maria Louzada; Herculano, Anderson Manoel
2014-09-01
Alarm reactions to a substance secreted by the damaged skin of conspecifics and closely-related species are increasingly being recognized as fear-like responses in fish. The neurochemical underpinnings of these effects are so far unknown; however, given the role of the serotonergic system on defensive behavior, it is possible that the alarm reaction is mediated by this monoamine. Exposure to conspecific alarm substance (CAS) increased anxiety-like behavior in the light/dark test in zebrafish and decreased nocifensive behavior. These effects were accompanied by increases in blood glucose, hemoglobin, epinephrine and norepinephrine levels, as well as extracellular levels of serotonin in the brain. Pretreatment with fluoxetine blocked the anxiogenic effects of CAS on the light/dark test as well as all physiological parameters and the increase in extracellular brain 5-HT, but not the reduction in nocifensive behavior. Conversely, pretreatment with the 5-HT1AR antagonist WAY 100635 blocked the effects on nocifensive behavior, but not the effects on anxiety-like behavior nor on physiological parameters. These results point to an important and complex role of the serotonergic system in the mediation of fear-potentiated behavior in the light/dark test and in fear-induced analgesia in zebrafish. Copyright © 2014 Elsevier Inc. All rights reserved.
Learning and signal copying facilitate communication among bird species
Wheatcroft, David; Price, Trevor D.
2013-01-01
Signals relevant to different sets of receivers in different contexts create a conflict for signal design. A classic example is vocal alarm signals, often used both during intraspecific and interspecific interactions. How can signals alert individuals from a variety of other species in some contexts, while also maintaining efficient communication among conspecifics? We studied heterospecific responses to avian alarm signals that drive the formation of anti-predator groups but are also used during intraspecific interactions. In three species-rich communities in the western Himalayas, alarm signals vary drastically across species. We show that, independently of differences in their calls, birds respond strongly to the alarm signals of other species with which they co-occur and much more weakly to those of species with which they do not co-occur. These results suggest that previous exposure and learning maintain heterospecific responses in the face of widespread signal divergence. At an area where only two species regularly interact, one species' calls incorporate the call of the other. We demonstrate experimentally that signal copying allows strong responses even without previous exposure and suggest that such hybrid calls may be especially favoured when pairwise interactions between species are strong. PMID:23446529
Decisional Bias as Implicit Moral Judgment
ERIC Educational Resources Information Center
Spring, Toni; Saltzstein, Herbert D.
2017-01-01
Decisional bias (false alarm rate) when judging the guilt/innocence of a suspect is offered as an implicit measure of moral judgment. Combining two data sets, 215 participants, ages 10-12, 13-15, and 16-18 watched the visually identical film involving a person setting a fire, framed either as (1) intentional but not resulting in a fire (BI-NF),…
Evaluation of pre-hospital transport time of stroke patients to thrombolytic treatment.
Simonsen, Sofie Amalie; Andresen, Morten; Michelsen, Lene; Viereck, Søren; Lippert, Freddy K; Iversen, Helle Klingenberg
2014-11-13
Effective treatment of stroke is time dependent. Pre-hospital management is an important link in reducing the time from occurrence of stroke symptoms to effective treatment. The aim of this study was to evaluate time used by emergency medical services (EMS) for stroke patients during a five-year period in order to identify potential delays and evaluate the reorganization of EMS in Copenhagen in 2009. We performed a retrospective analysis of ambulance records from stroke patients suitable for thrombolysis from 1 January 2006 to 7 July 2011. We noted response time from dispatch of the ambulance to arrival at the scene, on-scene time and transport time to the hospital-in total, alarm-to-door time. In addition, we noted baseline characteristics. We reviewed 481 records (58% male, median age 66 years). The median (IQR) alarm-to-door time in minutes was 41 (33-52), of which 18 (12-24) minutes were spent on scene. Response time was reduced from the period before to the period after reorganization (7 vs. 5 minutes, p <0.001). In a linear multiple regression model, higher patient age and longer distance to the hospital correlated with significantly longer transportation time (p <0.001). This study shows an unchanged alarm-to-door time of 41 minutes over a five-year period. Response time, but not total alarm-to-door time, was reduced during the five years. On-scene time constituted nearly half of the total alarm-to-door time and is thus a point of focus for improvement.
McGrath, Susan P; Pyke, Joshua; Taenzer, Andreas H
2017-06-01
Technology advances make it possible to consider continuous acoustic respiratory rate monitoring as an integral component of physiologic surveillance systems. This study explores technical and logistical aspects of augmenting pulse oximetry-based patient surveillance systems with continuous respiratory rate monitoring and offers some insight into the impact on patient deterioration detection that may result. Acoustic respiratory rate sensors were introduced to a general care pulse oximetry-based surveillance system with respiratory rate alarms deactivated. Simulation was used after 4324 patient days to determine appropriate alarm thresholds for respiratory rate, which were then activated. Data were collected for an additional 4382 patient days. Physiologic parameters, alarm data, sensor utilization and patient/staff feedback were collected throughout the study and analyzed. No notable technical or workflow issues were observed. Sensor utilization was 57 %, with patient refusal leading reasons for nonuse (22.7 %). With respiratory rate alarm thresholds set to 6 and 40 breaths/min., the majority of nurse pager clinical notifications were triggered by low oxygen saturation values (43 %), followed by low respiratory rate values (21 %) and low pulse rate values (13 %). Mean respiratory rate collected was 16.6 ± 3.8 breaths/min. The vast majority (82 %) of low oxygen saturation states coincided with normal respiration rates of 12-20 breaths/min. Continuous respiratory rate monitoring can be successfully added to a pulse oximetry-based surveillance system without significant technical, logistical or workflow issues and is moderately well-tolerated by patients. Respiratory rate sensor alarms did not significantly impact overall system alarm burden. Respiratory rate and oxygen saturation distributions suggest adding continuous respiratory rate monitoring to a pulse oximetry-based surveillance system may not significantly improve patient deterioration detection.
The INTELSAT VI SSTDMA network diagnostic system
NASA Astrophysics Data System (ADS)
Tamboli, Satish P.; Zhu, Xiaobo; Wilkins, Kim N.; Gupta, Ramesh K.
The system-level design of an expert-system-based, near-real-time diagnostic system for INTELSAT VI satellite-switched time-division multiple access (SSTDMA) network is described. The challenges of INTELSAT VI diagnostics are discussed, along with alternative approaches for network diagnostics and the rationale for choosing a method based on burst unique-word detection. The focal point of the diagnostic system is the diagnostic processor, which resides in the central control and monitoring facility known as the INTELSAT Operations Center TDMA Facility (IOCTF). As real-time information such as burst unique-word detection data, reference terminal status data, and satellite telemetry alarm data are received at the IOCTF, the diagnostic processor continuously monitors the data streams. When a burst status change is detected, a 'snapshot' of the real-time data is forwarded to the expert system. Receipt of the change causes a set of rules to be invoked which associate the traffic pattern with a set of probable causes. A user-friendly interface allows a graphical view of the burst time plan and provides the ability to browse through the knowledge bases.
ERIC Educational Resources Information Center
Gerhardt, Ira
2015-01-01
An experiment was conducted over three recent semesters of an introductory calculus course to test whether it was possible to quantify the effect that difficulty with basic algebraic and arithmetic computation had on individual performance. Points lost during the term were classified as being due to either algebraic and arithmetic mistakes…
Safety analysis of proposed data-driven physiologic alarm parameters for hospitalized children.
Goel, Veena V; Poole, Sarah F; Longhurst, Christopher A; Platchek, Terry S; Pageler, Natalie M; Sharek, Paul J; Palma, Jonathan P
2016-12-01
Modification of alarm limits is one approach to mitigating alarm fatigue. We aimed to create and validate heart rate (HR) and respiratory rate (RR) percentiles for hospitalized children, and analyze the safety of replacing current vital sign reference ranges with proposed data-driven, age-stratified 5th and 95th percentile values. In this retrospective cross-sectional study, nurse-charted HR and RR data from a training set of 7202 hospitalized children were used to develop percentile tables. We compared 5th and 95th percentile values with currently accepted reference ranges in a validation set of 2287 patients. We analyzed 148 rapid response team (RRT) and cardiorespiratory arrest (CRA) events over a 12-month period, using HR and RR values in the 12 hours prior to the event, to determine the proportion of patients with out-of-range vitals based upon reference versus data-driven limits. There were 24,045 (55.6%) fewer out-of-range measurements using data-driven vital sign limits. Overall, 144/148 RRT and CRA patients had out-of-range HR or RR values preceding the event using current limits, and 138/148 were abnormal using data-driven limits. Chart review of RRT and CRA patients with abnormal HR and RR per current limits considered normal by data-driven limits revealed that clinical status change was identified by other vital sign abnormalities or clinical context. A large proportion of vital signs in hospitalized children are outside presently used norms. Safety evaluation of data-driven limits suggests they are as safe as those currently used. Implementation of these parameters in physiologic monitors may mitigate alarm fatigue. Journal of Hospital Medicine 2015;11:817-823. © 2015 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.
Sensor fusion methods for reducing false alarms in heart rate monitoring.
Borges, Gabriel; Brusamarello, Valner
2016-12-01
Automatic patient monitoring is an essential resource in hospitals for good health care management. While alarms caused by abnormal physiological conditions are important for the delivery of fast treatment, they can be also a source of unnecessary noise because of false alarms caused by electromagnetic interference or motion artifacts. One significant source of false alarms is related to heart rate, which is triggered when the heart rhythm of the patient is too fast or too slow. In this work, the fusion of different physiological sensors is explored in order to create a robust heart rate estimation. A set of algorithms using heart rate variability index, Bayesian inference, neural networks, fuzzy logic and majority voting is proposed to fuse the information from the electrocardiogram, arterial blood pressure and photoplethysmogram. Three kinds of information are extracted from each source, namely, heart rate variability, the heart rate difference between sensors and the spectral analysis of low and high noise of each sensor. This information is used as input to the algorithms. Twenty recordings selected from the MIMIC database were used to validate the system. The results showed that neural networks fusion had the best false alarm reduction of 92.5 %, while the Bayesian technique had a reduction of 84.3 %, fuzzy logic 80.6 %, majority voter 72.5 % and the heart rate variability index 67.5 %. Therefore, the proposed algorithms showed good performance and could be useful in bedside monitors.
[Evaluation of the analyzer of hematology Beckman Coulter® HmX™ in the university hospital of Oran].
Zmouli, N; Moulasserdoun, K; Seghier, F
2013-11-01
The choice of an automaton of haematology is a determining stage, which has to take into account at the same time the quality of the results and the economic imperatives: workload, structure and organization of the laboratory. [corrected] It is in this spirit that we estimated during a period of 3 months the analyzer of haematology: the HmX™ Coulter with boatman of samples of the company Beckman. This automaton realizes the blood numeration, the formula leukocytic and the reticulocyte count. At first, we estimated the appropriate characteristics of device. Secondly, we estimated the relevance, the sensibility and the specificity of the alarms by comparing with the reference method, which is the optical microscopy. For that purpose, 125 blood smears resulting from service of haematology and from resuscitation were examined in optical microscopy. The technical tests were realized according to the recommendations of the International committee for evaluation of automatons of haematology. The analytical performances were satisfactory in particular the big interval of linearity and the absence of contamination. As regards the evaluation of the alarms system: rate of rejection is 63%, the sensibility 86%, the specificity 70%, the positive predictive value 80%, the negative predictive value 78% and the efficiency 80%. The alarms myelaemia and atypical lymphocytes were never sources of false negatives. The alarms erythroblasts and platelet aggregates did not engendered positive forgery. The blast cell alarm was responsible for a single case of false negative. The faithfulness of automaton is satisfactory: the absence of contamination, the big interval of linearity for the leukocytes, the red blood cells and the platelets as well as a good relevance of the alarms with regard to the anomalies found on the peripheral blood smear. From the user-friendliness and practicability point of view, the HmX™ Coulter was deeply appreciated. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Saving Quality from Quality Assurance. Perspective
ERIC Educational Resources Information Center
Stephenson, Sandra L.
2004-01-01
The word 'quality' has become a 'central term in the lexicon of contemporary higher education and a major point of interest to various interest groups'. As quality assurance systems have developed around the world, certain assumptions are becoming alarmingly widespread: for example that quality assurance is new to higher education, that quality…
An Information Security Control Assessment Methodology for Organizations
ERIC Educational Resources Information Center
Otero, Angel R.
2014-01-01
In an era where use and dependence of information systems is significantly high, the threat of incidents related to information security that could jeopardize the information held by organizations is more and more serious. Alarming facts within the literature point to inadequacies in information security practices, particularly the evaluation of…
Improving the Achievement of Minority Students.
ERIC Educational Resources Information Center
Murphy, John A.
1988-01-01
In 1984, a Maryland elementary school publicized standardized test scores showing black students trailing white students by 25 points. Alarmed by this gap, a district task force found the root cause--negative attitudes about black students' potential--and launched an effective schools process in 171 schools. Two supporting programs are described.…
Disrupting the School-to-Prison Pipeline
ERIC Educational Resources Information Center
Bahena, Sofía, Ed.; Cooc, North, Ed.; Currie-Rubin, Rachel, Ed.; Kuttner, Paul, Ed.; Ng, Monica, Ed.
2012-01-01
A trenchant and wide-ranging look at this alarming national trend, "Disrupting the School-to-Prison Pipeline" is unsparing in its account of the problem while pointing in the direction of meaningful and much-needed reforms. The "school-to-prison pipeline" has received much attention in the education world over the past few…
40 CFR 63.1367 - Recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and time, with a brief explanation of the cause of the alarm and the corrective action taken. (6) The...) All maintenance performed on the air pollution control equipment. (11) If the owner or operator elects... human health or the environment than if the emission points were controlled according to the provisions...
Pattern recognition by wavelet transforms using macro fibre composites transducers
NASA Astrophysics Data System (ADS)
Ruiz de la Hermosa González-Carrato, Raúl; García Márquez, Fausto Pedro; Dimlaye, Vichaar; Ruiz-Hernández, Diego
2014-10-01
This paper presents a novel pattern recognition approach for a non-destructive test based on macro fibre composite transducers applied in pipes. A fault detection and diagnosis (FDD) method is employed to extract relevant information from ultrasound signals by wavelet decomposition technique. The wavelet transform is a powerful tool that reveals particular characteristics as trends or breakdown points. The FDD developed for the case study provides information about the temperatures on the surfaces of the pipe, leading to monitor faults associated with cracks, leaks or corrosion. This issue may not be noticeable when temperatures are not subject to sudden changes, but it can cause structural problems in the medium and long-term. Furthermore, the case study is completed by a statistical method based on the coefficient of determination. The main purpose will be to predict future behaviours in order to set alarm levels as a part of a structural health monitoring system.
Automatic classification of visual evoked potentials based on wavelet decomposition
NASA Astrophysics Data System (ADS)
Stasiakiewicz, Paweł; Dobrowolski, Andrzej P.; Tomczykiewicz, Kazimierz
2017-04-01
Diagnosis of part of the visual system, that is responsible for conducting compound action potential, is generally based on visual evoked potentials generated as a result of stimulation of the eye by external light source. The condition of patient's visual path is assessed by set of parameters that describe the time domain characteristic extremes called waves. The decision process is compound therefore diagnosis significantly depends on experience of a doctor. The authors developed a procedure - based on wavelet decomposition and linear discriminant analysis - that ensures automatic classification of visual evoked potentials. The algorithm enables to assign individual case to normal or pathological class. The proposed classifier has a 96,4% sensitivity at 10,4% probability of false alarm in a group of 220 cases and area under curve ROC equals to 0,96 which, from the medical point of view, is a very good result.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palazzo, S.; Vagliasindi, G.; Arena, P.
2010-08-15
In the past years cameras have become increasingly common tools in scientific applications. They are now quite systematically used in magnetic confinement fusion, to the point that infrared imaging is starting to be used systematically for real-time machine protection in major devices. However, in order to guarantee that the control system can always react rapidly in case of critical situations, the time required for the processing of the images must be as predictable as possible. The approach described in this paper combines the new computational paradigm of cellular nonlinear networks (CNNs) with field-programmable gate arrays and has been tested inmore » an application for the detection of hot spots on the plasma facing components in JET. The developed system is able to perform real-time hot spot recognition, by processing the image stream captured by JET wide angle infrared camera, with the guarantee that computational time is constant and deterministic. The statistical results obtained from a quite extensive set of examples show that this solution approximates very well an ad hoc serial software algorithm, with no false or missed alarms and an almost perfect overlapping of alarm intervals. The computational time can be reduced to a millisecond time scale for 8 bit 496x560-sized images. Moreover, in our implementation, the computational time, besides being deterministic, is practically independent of the number of iterations performed by the CNN - unlike software CNN implementations.« less
On some methods for assessing earthquake predictions
NASA Astrophysics Data System (ADS)
Molchan, G.; Romashkova, L.; Peresan, A.
2017-09-01
A regional approach to the problem of assessing earthquake predictions inevitably faces a deficit of data. We point out some basic limits of assessment methods reported in the literature, considering the practical case of the performance of the CN pattern recognition method in the prediction of large Italian earthquakes. Along with the classical hypothesis testing, a new game approach, the so-called parimutuel gambling (PG) method, is examined. The PG, originally proposed for the evaluation of the probabilistic earthquake forecast, has been recently adapted for the case of 'alarm-based' CN prediction. The PG approach is a non-standard method; therefore it deserves careful examination and theoretical analysis. We show that the PG alarm-based version leads to an almost complete loss of information about predicted earthquakes (even for a large sample). As a result, any conclusions based on the alarm-based PG approach are not to be trusted. We also show that the original probabilistic PG approach does not necessarily identifies the genuine forecast correctly among competing seismicity rate models, even when applied to extensive data.
Evaluation of continuous air monitor placement in a plutonium facility.
Whicker, J J; Rodgers, J C; Fairchild, C I; Scripsick, R C; Lopez, R C
1997-05-01
Department of Energy appraisers found continuous air monitors at Department of Energy plutonium facilities alarmed less than 30% of the time when integrated room plutonium air concentrations exceeded 500 DAC-hours. Without other interventions, this alarm percentage suggests the possibility that workers could be exposed to high airborne concentrations without continuous air monitor alarms. Past research has shown that placement of continuous air monitors is a critical component in rapid and reliable detection of airborne releases. At Los Alamos National Laboratory and many other Department of Energy plutonium facilities, continuous air monitors have been primarily placed at ventilation exhaust points. The purpose of this study was to evaluate and compare the effectiveness of exhaust register placement of workplace continuous air monitors with other sampling locations. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories at Los Alamos National Laboratory. An array of laser particle counters positioned in the rooms measured time-resolved aerosol dispersion. Results showed alternative placement of air samplers generally resulted in aerosol detection that was faster, often more sensitive, and equally reliable compared with samplers at exhaust registers.
NASA Astrophysics Data System (ADS)
Tsutsumi, Shigeyoshi; Wada, Takahiro; Akita, Tokihiko; Doi, Shun'ichi
Driver's workload tends to be increased during driving under complicated traffic environments like a lane change. In such cases, rear collision warning is effective for reduction of cognitive workload. On the other hand, it is pointed out that false alarm or missing alarm caused by sensor errors leads to decrease of driver' s trust in the warning system and it can result in low efficiency of the system. Suppose that reliability information of the sensor is provided in real-time. In this paper, we propose a new warning method to increase driver' s trust in the system even with low sensor reliability utilizing the sensor reliability information. The effectiveness of the warning methods is shown by driving simulator experiments.
Development of an alarm sound database and simulator.
Takeuchi, Akihiro; Hirose, Minoru; Shinbo, Toshiro; Imai, Megumi; Mamorita, Noritaka; Ikeda, Noriaki
2006-10-01
The purpose of this study was to develop an interactive software package of alarm sounds to present, recognize and share problems about alarm sounds among medical staff and medical manufactures. The alarm sounds were recorded in variable alarm conditions in a WAV file. The alarm conditions were arbitrarily induced by modifying attachments of various medical devices. The software package that integrated an alarm sound database and simulator was used to assess the ability to identify the monitor that sounded the alarm for the medical staff. Eighty alarm sound files (40MB in total) were recorded from 41 medical devices made by 28 companies. There were three pairs of similar alarm sounds that could not easily be distinguished, two alarm sounds which had a different priority, either low or high. The alarm sound database was created in an Excel file (ASDB.xls 170 kB, 40 MB with photos), and included a list of file names that were hyperlinked to alarm sound files. An alarm sound simulator (AlmSS) was constructed with two modules for simultaneously playing alarm sound files and for designing new alarm sounds. The AlmSS was used in the assessing procedure to determine whether 19 clinical engineers could identify 13 alarm sounds only by their distinctive sounds. They were asked to choose from a list of devices and to rate the priority of each alarm. The overall correct identification rate of the alarm sounds was 48%, and six characteristic alarm sounds were correctly recognized by beetween 63% to 100% of the subjects. The overall recognition rate of the alarm sound priority was only 27%. We have developed an interactive software package of alarm sounds by integrating the database and the alarm sound simulator (URL: http://info.ahs.kitasato-u.ac.jp/tkweb/alarm/asdb.html ). The AlmSS was useful for replaying multiple alarm sounds simultaneously and designing new alarm sounds interactively.
Ansari, A H; Cherian, P J; Dereymaeker, A; Matic, V; Jansen, K; De Wispelaere, L; Dielman, C; Vervisch, J; Swarte, R M; Govaert, P; Naulaers, G; De Vos, M; Van Huffel, S
2016-09-01
After identifying the most seizure-relevant characteristics by a previously developed heuristic classifier, a data-driven post-processor using a novel set of features is applied to improve the performance. The main characteristics of the outputs of the heuristic algorithm are extracted by five sets of features including synchronization, evolution, retention, segment, and signal features. Then, a support vector machine and a decision making layer remove the falsely detected segments. Four datasets including 71 neonates (1023h, 3493 seizures) recorded in two different university hospitals, are used to train and test the algorithm without removing the dubious seizures. The heuristic method resulted in a false alarm rate of 3.81 per hour and good detection rate of 88% on the entire test databases. The post-processor, effectively reduces the false alarm rate by 34% while the good detection rate decreases by 2%. This post-processing technique improves the performance of the heuristic algorithm. The structure of this post-processor is generic, improves our understanding of the core visually determined EEG features of neonatal seizures and is applicable for other neonatal seizure detectors. The post-processor significantly decreases the false alarm rate at the expense of a small reduction of the good detection rate. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
ECG signal quality during arrhythmia and its application to false alarm reduction.
Behar, Joachim; Oster, Julien; Li, Qiao; Clifford, Gari D
2013-06-01
An automated algorithm to assess electrocardiogram (ECG) quality for both normal and abnormal rhythms is presented for false arrhythmia alarm suppression of intensive care unit (ICU) monitors. A particular focus is given to the quality assessment of a wide variety of arrhythmias. Data from three databases were used: the Physionet Challenge 2011 dataset, the MIT-BIH arrhythmia database, and the MIMIC II database. The quality of more than 33 000 single-lead 10 s ECG segments were manually assessed and another 12 000 bad-quality single-lead ECG segments were generated using the Physionet noise stress test database. Signal quality indices (SQIs) were derived from the ECGs segments and used as the inputs to a support vector machine classifier with a Gaussian kernel. This classifier was trained to estimate the quality of an ECG segment. Classification accuracies of up to 99% on the training and test set were obtained for normal sinus rhythm and up to 95% for arrhythmias, although performance varied greatly depending on the type of rhythm. Additionally, the association between 4050 ICU alarms from the MIMIC II database and the signal quality, as evaluated by the classifier, was studied. Results suggest that the SQIs should be rhythm specific and that the classifier should be trained for each rhythm call independently. This would require a substantially increased set of labeled data in order to train an accurate algorithm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasemir, Kay; Hartman, Steven M
2009-01-01
A new alarm system toolkit has been implemented at SNS. The toolkit handles the Central Control Room (CCR) 'annunciator', or audio alarms. For the new alarm system to be effective, the alarms must be meaningful and properly configured. Along with the implementation of the new alarm toolkit, a thorough documentation and rationalization of the alarm configuration is taking place. Requirements and maintenance of a robust alarm configuration have been gathered from system and operations experts. In this paper we present our practical experience with the vacuum system alarm handling configuration of the alarm toolkit.
Smoke alarm tests may not adequately indicate smoke alarm function.
Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Young, Tracy
2011-01-01
Smoke alarms are one of the most promoted prevention strategies to reduce residential fire deaths, and they can reduce residential fire deaths by half. Smoke alarm function can be measured by two tests: the smoke alarm button test and the chemical smoke test. Using results from a randomized trial of smoke alarms, we compared smoke alarm response to the button test and the smoke test. The smoke alarms found in the study homes at baseline were tested, as well as study alarms placed into homes as part of the randomized trial. Study alarms were tested at 12 and 42 months postinstallation. The proportion of alarms that passed the button test but not the smoke test ranged from 0.5 to 5.8% of alarms; this result was found most frequently among ionization alarms with zinc or alkaline batteries. These alarms would indicate to the owner (through the button test) that the smoke alarm was working, but the alarm would not actually respond in the case of a fire (as demonstrated by failing the smoke test). The proportion of alarms that passed the smoke test but not the button test ranged from 1.0 to 3.0%. These alarms would appear nonfunctional to the owner (because the button test failed), even though the alarm would operate in response to a fire (as demonstrated by passing the smoke test). The general public is not aware of the potential for inaccuracy in smoke alarm tests, and burn professionals can advocate for enhanced testing methods. The optimal test to determine smoke alarm function is the chemical smoke test.
The cognitive activation theory of stress.
Ursin, Holger; Eriksen, Hege R
2004-06-01
This paper presents a cognitive activation theory of stress (CATS), with a formal system of systematic definitions. The term "stress" is used for four aspects of "stress", stress stimuli, stress experience, the non-specific, general stress response, and experience of the stress response. These four meanings may be measured separately. The stress response is a general alarm in a homeostatic system, producing general and unspecific neurophysiological activation from one level of arousal to more arousal. The stress response occurs whenever there is something missing, for instance a homeostatic imbalance, or a threat to homeostasis and life of the organism. Formally, the alarm occurs when there is a discrepancy between what should be and what is-between the value a variable should have (set value (SV)), and the real value (actual value (AV)) of the same variable. The stress response, therefore, is an essential and necessary physiological response. The unpleasantness of the alarm is no health threat. However, if sustained, the response may lead to illness and disease through established pathophysiological processes ("allostatic load"). The alarm elicits specific behaviors to cope with the situation. The level of alarm depends on expectancy of the outcome of stimuli and the specific responses available for coping. Psychological defense is defined as a distortion of stimulus expectancies. Response outcome expectancies are defined as positive, negative, or none, to the available responses. This offers formal definitions of coping, hopelessness, and helplessness that are easy to operationalize in man and in animals. It is an essential element of CATS that only when coping is defined as positive outcome expectancy does the concept predict relations to health and disease.
Analysis of Engineering Discipline Grade Trends
ERIC Educational Resources Information Center
McAllister, Charles D.; Jiang, Xiaoyue; Aghazadeh, Fereydoun
2008-01-01
Among the academic community, there is a perception that there is an upward shift in grade point average over an extended period of time without a corresponding increase in achievement. This trend has become an alarming topic among educators, industry and the general public. Some attribute increases in GPA to improvements in student quality while…
Implementing Peer-Assisted Writing Support in German Secondary Schools
ERIC Educational Resources Information Center
Rensing, Julia; Vierbuchen, Marie-Christine; Hillenbrand, Clemens; Grünke, Matthias
2016-01-01
The alarming results of large studies such as the National Assessment of Educational Progress (NAEP; National Center for Education Statistics, 2012) point to an urgent need for writing support and call for specific and effective methods to foster writing competencies. The main purpose of this paper is to describe an innovative peer-assisted…
Childhood Obesity in the Testing Era: What Teachers and Schools Can Do!
ERIC Educational Resources Information Center
Winter, Suzanne M.
2009-01-01
In this era of increasing accountability and high-stakes testing in schools, a serious paradox has surfaced. Children are becoming overweight at an alarming rate, and mounting evidence points to a relationship between obesity and poor school performance. Ironically, pressure to improve children's academic achievement has led many schools to adopt…
Soviet Computers and Cybernetics: Shortcomings and Military Applications.
1980-06-01
FOOTNOTES.......................................24 BIBLIOGRAPHY......................................28 INTRODUCTION Military scientific technological...exploration which have alarmed some Western analysts. America’s scientific and technological advantages are integral elements in the delicate world balance...inferior quantity only up to a point, where superior numbers take over. A major element in the military scientific technological competition between
Yang, Jingzhen; Jones, Michael P; Cheng, Gang; Ramirez, Marizen; Taylor, Craig; Peek-Asa, Corinne
2011-06-01
Many home fires begin in the kitchen. Kitchen smoke alarms are more likely to produce nuisance alarms, but few previous studies have examined the role of alarm sensor and battery types on the functionality of smoke alarms located nearest to the kitchen. Data were analysed from a 2×2 factorial randomised controlled trial conducted in rural Iowa homes (n=628). Enrolled households were randomly assigned into one of four smoke alarm/battery combinations: ionisation/zinc, ionisation/lithium, photoelectric/zinc and photoelectric/lithium. Alarm functionality was determined using a smoke test. Alarm type and battery type were compared using an intent-to-treat analysis. Logistic regression was used to identify factors that might impact the functionality of smoke alarms located nearest to the kitchen 42 months after installation. Photoelectric alarms with lithium batteries had the highest rate of functionality (90.2%), whereas ionisation alarms with carbon/zinc batteries had the lowest (76.5%). Forty-two months following installation, 6.4% more of photoelectric alarms were functional than ionisation alarms, and 7.9% more of alarms with lithium batteries were functional than those with carbon/zinc batteries. Logistic regression revealed that when the indicator of nuisance alarms was included, the effect of alarm type became statistically insignificant and ionisation alarms were less likely to be functional at 42 months, partly due to increased nuisance alarms. Alarm type is an important consideration for certain locations. Photoelectric alarms may be more appropriate for installation nearest to the kitchen despite their increased cost. These findings can help guide consumer choices to increase protection against home fire-related injuries and deaths.
False Alarms and Overmonitoring: Major Factors in Alarm Fatigue Among Labor Nurses.
Simpson, Kathleen Rice; Lyndon, Audrey
2018-06-08
Nurses can be exposed to hundreds of alarms during their shift, contributing to alarm fatigue. The purposes were to explore similarities and differences in perceptions of clinical alarms by labor nurses caring for generally healthy women compared with perceptions of adult intensive care unit (ICU) and neonatal ICU nurses caring for critically ill patients and to seek nurses' suggestions for potential improvements. Nurses were asked via focus groups about the utility of clinical alarms from medical devices. There was consensus that false alarms and too many devices generating alarms contributed to alarm fatigue, and most alarms lacked clinical relevance. Nurses identified certain types of alarms that they responded to immediately, but the vast majority of the alarms did not contribute to their clinical assessment or planned nursing care. Monitoring only those patients who need it and only those physiologic values that are warranted, based on patient condition, may decrease alarm burden.
Using modeling and rehearsal to teach fire safety to children with autism.
Garcia, David; Dukes, Charles; Brady, Michael P; Scott, Jack; Wilson, Cynthia L
2016-09-01
We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to novel settings and maintained during a 5-week follow-up in both training and generalization settings. © 2016 Society for the Experimental Analysis of Behavior.
Studies of recognition with multitemporal remote sensor data
NASA Technical Reports Server (NTRS)
Malila, W. A.; Hieber, R. H.; Cicone, R. C.
1975-01-01
Characteristics of multitemporal data and their use in recognition processing were investigated. Principal emphasis was on satellite data collected by the LANDSAT multispectral scanner and on temporal changes throughout a growing season. The effects of spatial misregistration on recognition performance with multitemporal data were examined. A capability to compute probabilities of detection and false alarm was developed and used with simulated distributions for misregistered pixels. Wheat detection was found to be degraded and false alarms increased by misregistration effects. Multitemporal signature characteristics and multitemporal recognition processing were studied to gain insights into problems associated with this approach and possible improvements. Recognition performance with one multitemporal data set displayed marked improvements over results from single-time data.
van den Heuvel, Maria Elisabeth Nicoletta; van Zanten, Henriette A; Bachman, Tom E; Te Pas, Arjan B; van Kaam, Anton H; Onland, Wes
2018-06-01
To investigate the effect of different pulse oximetry (SpO 2 ) target range settings during automated fraction of inspired oxygen control (A-FiO 2 ) on time spent within a clinically set SpO 2 alarm range in oxygen-dependent infants on noninvasive respiratory support. Forty-one preterm infants (gestational age [median] 26 weeks, age [median] 21 days) on FiO 2 >0.21 receiving noninvasive respiratory support were subjected to A-FiO 2 using 3 SpO 2 target ranges (86%-94%, 88%-92%, or 89%-91%) in random order for 24 hours each. Before switching to the next target range, SpO 2 was manually controlled for 24 hours (washout period). The primary outcome was the time spent within the clinically set alarm limits of 86%-94%. The percent time within the 86%-94% SpO 2 alarm range was similar for all 3 A-FiO 2 target ranges (74%). Time spent in hyperoxemia was not significantly different between target ranges. However, the time spent in severe hypoxemia (SpO 2 <80%) was significantly reduced during the narrowed target ranges of A-FiO 2 (88%-92%; 1.9%, 89%-91%; 1.7%) compared with the wide target range (86%-94%; 3.4%, P < .001). There were no differences between the 88%-92% and 89-91% target range. Narrowing the target range of A-FiO 2 to the desired median ±2% is effective in reducing the time spent in hypoxemia, without increasing the risk of hyperoxemia. www.trialregister.nl: NTR4368. Copyright © 2018 Elsevier Inc. All rights reserved.
Closed-loop control of SaO2 in the neonate.
Morozoff, P E; Evans, R W
1992-01-01
A microprocessor-based device has been designed to control oxygen saturation (SaO2) in neonates by adjusting the inspired air-oxygen mixture (FiO2) delivered by a mechanical blender. The user sets a target SaO2, which the controller attempts to maintain. Alarms are actuated if the neonate's SaO2 is outside predefined limits. SaO2 levels are extracted from a commercial pulse oximeter and analyzed by an eight-bit microprocessing unit (MPU). Delivered percentages of FiO2 are adjusted by a motorized air-oxygen blender. The controller has a menu-driven user interface and can graphically present four-hour trends of the SaO2, FiO2, or blender setting. Sixteen hours of collected data can be stored and later downloaded to a personal computer. A real-time multitasking operating system forms the nucleus of the controller's software. Major tasks that share MPU time are control, filtering, user display, data collection, data archiving, alarm monitoring, and user input. Analog SaO2 levels are read and converted to digital values, which are then filtered to extract noise. A differential control algorithm is used to determine the required FiO2 blender setting. The blender is then adjusted to the new setting, after which the controller waits to repeat the process of sampling SaO2 and adjusting FiO2. System response time and blender increments are adjustable to allow a user to tune the controller to the patient's needs. Alarm conditions of concern within the device are SaO2 and FiO2 sensor disconnection, blender disconnection, and SaO2 limiting errors. In preliminary trials, for a target of 92.0% SaO2, a prototype controller maintained an average of 91.6% with a standard deviation of 5.0% over a one-hour period.(ABSTRACT TRUNCATED AT 250 WORDS)
Gambling score in earthquake prediction analysis
NASA Astrophysics Data System (ADS)
Molchan, G.; Romashkova, L.
2011-03-01
The number of successes and the space-time alarm rate are commonly used to characterize the strength of an earthquake prediction method and the significance of prediction results. It has been recently suggested to use a new characteristic to evaluate the forecaster's skill, the gambling score (GS), which incorporates the difficulty of guessing each target event by using different weights for different alarms. We expand parametrization of the GS and use the M8 prediction algorithm to illustrate difficulties of the new approach in the analysis of the prediction significance. We show that the level of significance strongly depends (1) on the choice of alarm weights, (2) on the partitioning of the entire alarm volume into component parts and (3) on the accuracy of the spatial rate measure of target events. These tools are at the disposal of the researcher and can affect the significance estimate. Formally, all reasonable GSs discussed here corroborate that the M8 method is non-trivial in the prediction of 8.0 ≤M < 8.5 events because the point estimates of the significance are in the range 0.5-5 per cent. However, the conservative estimate 3.7 per cent based on the number of successes seems preferable owing to two circumstances: (1) it is based on relative values of the spatial rate and hence is more stable and (2) the statistic of successes enables us to construct analytically an upper estimate of the significance taking into account the uncertainty of the spatial rate measure.
Campollo-Ovalle, A; Sánchez, D
2018-03-16
Lestrimelitta spp. are stingless bees that steal food and nesting materials from other highly social bees to survive. Though most of their victim species respond, either aggressively or submissively, to cephalic components of Lestrimelitta, little is known about if such response changes at some point during extended periods of exposure. Moreover, potential synergistic effects due to a mixture of victim's alarm/defense pheromones and Lestrimelitta mandibular pheromones, like in an actual attack, have not been examined so far. In this paper, we investigated the response of two species of non-robber stingless bees, Scaptotrigona mexicana (Guérin) and Tetragonisca angustula (Latreille), to (a) cephalic compounds from crushed heads of nestmates, (b) cephalic compounds of Lestrimelitta niitkib (Ayala), and (c) a mixture of (a) and (b). We found that even though T. angustula did not react to nestmates' crushed head, its response towards L. niitkib cephalic compounds was stronger and lasted longer than that of S. mexicana. Interestingly, the addition of crushed heads of the non-robber species to L. niitkib crushed heads caused no significant increase in the alarm response of both species. It may be that the absence of an alarm pheromone in T. angustula made this species more receptive to extraneous odors, which is not the case for S. mexicana; however, more species must be studied to elucidate any pattern regarding the absence/presence of alarm pheromones and the corresponding response to intruders' pheromones.
Machine learning for real time remote detection
NASA Astrophysics Data System (ADS)
Labbé, Benjamin; Fournier, Jérôme; Henaff, Gilles; Bascle, Bénédicte; Canu, Stéphane
2010-10-01
Infrared systems are key to providing enhanced capability to military forces such as automatic control of threats and prevention from air, naval and ground attacks. Key requirements for such a system to produce operational benefits are real-time processing as well as high efficiency in terms of detection and false alarm rate. These are serious issues since the system must deal with a large number of objects and categories to be recognized (small vehicles, armored vehicles, planes, buildings, etc.). Statistical learning based algorithms are promising candidates to meet these requirements when using selected discriminant features and real-time implementation. This paper proposes a new decision architecture benefiting from recent advances in machine learning by using an effective method for level set estimation. While building decision function, the proposed approach performs variable selection based on a discriminative criterion. Moreover, the use of level set makes it possible to manage rejection of unknown or ambiguous objects thus preserving the false alarm rate. Experimental evidences reported on real world infrared images demonstrate the validity of our approach.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...
21st Century Apprenticeships: Embracing Nontraditional Partnerships and Technologies
ERIC Educational Resources Information Center
Stoner, Gayla; Bird, Bruce; Gaal, John
2011-01-01
While concerns for skill shortages within the world of trades workers have been a focal point of a variety of recent studies and reports, the reactive alarm has not been sounded in the modernized registered apprenticeship program. Registered apprenticeship is a combination of on-the-job learning (OJL) and related classroom and shop instruction. A…
ERIC Educational Resources Information Center
Holburn, C. Steven; Dougher, Michael J.
1985-01-01
Techniques for training a severely retarded blind client to exit his living unit during a fire drill used a combination of negative and positive reinforcement. Following a shaping procedure, the client learned to leave his living unit from any internal point through generalization training and subsequent test probes. (Author/CL)
An integrated logit model for contamination event detection in water distribution systems.
Housh, Mashor; Ostfeld, Avi
2015-05-15
The problem of contamination event detection in water distribution systems has become one of the most challenging research topics in water distribution systems analysis. Current attempts for event detection utilize a variety of approaches including statistical, heuristics, machine learning, and optimization methods. Several existing event detection systems share a common feature in which alarms are obtained separately for each of the water quality indicators. Unifying those single alarms from different indicators is usually performed by means of simple heuristics. A salient feature of the current developed approach is using a statistically oriented model for discrete choice prediction which is estimated using the maximum likelihood method for integrating the single alarms. The discrete choice model is jointly calibrated with other components of the event detection system framework in a training data set using genetic algorithms. The fusing process of each indicator probabilities, which is left out of focus in many existing event detection system models, is confirmed to be a crucial part of the system which could be modelled by exploiting a discrete choice model for improving its performance. The developed methodology is tested on real water quality data, showing improved performances in decreasing the number of false positive alarms and in its ability to detect events with higher probabilities, compared to previous studies. Copyright © 2015 Elsevier Ltd. All rights reserved.
A random forest algorithm for nowcasting of intense precipitation events
NASA Astrophysics Data System (ADS)
Das, Saurabh; Chakraborty, Rohit; Maitra, Animesh
2017-09-01
Automatic nowcasting of convective initiation and thunderstorms has potential applications in several sectors including aviation planning and disaster management. In this paper, random forest based machine learning algorithm is tested for nowcasting of convective rain with a ground based radiometer. Brightness temperatures measured at 14 frequencies (7 frequencies in 22-31 GHz band and 7 frequencies in 51-58 GHz bands) are utilized as the inputs of the model. The lower frequency band is associated to the water vapor absorption whereas the upper frequency band relates to the oxygen absorption and hence, provide information on the temperature and humidity of the atmosphere. Synthetic minority over-sampling technique is used to balance the data set and 10-fold cross validation is used to assess the performance of the model. Results indicate that random forest algorithm with fixed alarm generation time of 30 min and 60 min performs quite well (probability of detection of all types of weather condition ∼90%) with low false alarms. It is, however, also observed that reducing the alarm generation time improves the threat score significantly and also decreases false alarms. The proposed model is found to be very sensitive to the boundary layer instability as indicated by the variable importance measure. The study shows the suitability of a random forest algorithm for nowcasting application utilizing a large number of input parameters from diverse sources and can be utilized in other forecasting problems.
Performance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.
Nizami, Shermeen; Greenwood, Kim; Barrowman, Nick; Harrold, JoAnn
2015-09-01
This crossover observational study compares the data characteristics and performance of new-generation Nellcor OXIMAX and Masimo SET SmartPod pulse oximeter technologies. The study was conducted independent of either original equipment manufacturer (OEM) across eleven preterm infants in a Neonatal Intensive Care Unit (NICU). The SmartPods were integrated with Dräger Infinity Delta monitors. The Delta monitor measured the heart rate (HR) using an independent electrocardiogram sensor, and the two SmartPods collected arterial oxygen saturation (SpO2) and pulse rate (PR). All patient data were non-Gaussian. Nellcor PR showed a higher correlation with the HR as compared to Masimo PR. The statistically significant difference found in their median values (1% for SpO2, 1 bpm for PR) was deemed clinically insignificant. SpO2 alarms generated by both SmartPods were observed and categorized for performance evaluation. Results for sensitivity, positive predictive value, accuracy and false alarm rates were Nellcor (80.3, 50, 44.5, 50%) and Masimo (72.2, 48.2, 40.6, 51.8%) respectively. These metrics were not statistically significantly different between the two pulse oximeters. Despite claims by OEMs, both pulse oximeters exhibited high false alarm rates, with no statistically or clinically significant difference in performance. These findings have a direct impact on alarm fatigue in the NICU. Performance evaluation studies can also impact medical device purchase decisions made by hospital administrators.
Six-month follow-up of lithium-battery smoke alarms and self-reported reasons for disabling.
Omaki, Elise; Shields, Wendy C; Frattaroli, Shannon; McDonald, Eileen; Jones, Vanya; Gielen, Andrea
2017-02-01
Although smoke alarms with lithium batteries are often marketed as '10-year alarms', on average, these alarms do not remain functional for 10 years. This paper describes self-reported reasons for non-working lithium-battery alarms 6-9 months following a smoke alarm installation programme. Data presented are for a cohort of 754 homes that participated in the installation programme and subsequently completed follow-up. A total of 1487 smoke alarms were installed. At follow-up, 126 alarms (8%) were missing and 37 (3%) were observed to be non-working. Of the non-working alarms, residents reported that they had been disabled 57% of the time. Reasons for disabling the alarms most often included that the battery was chirping (38%) or that it sounded while someone was cooking (24%). Smoke alarm installation programmes using lithium-battery alarms should consider highlighting education about smoke alarm maintenance, the hush feature and resources to replace alarms that malfunction soon after installation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Essential childbirth and postnatal interventions for improved maternal and neonatal health
2014-01-01
Childbirth and the postnatal period, spanning from right after birth to the following several weeks, presents a time in which the number of deaths reported still remain alarmingly high. Worldwide, about 800 women die from pregnancy- or childbirth-related complications daily while almost 75% of neonatal deaths occur within the first seven days of delivery and a vast majority of these occur in the first 24 hours. Unfortunately, this alarming trend of mortality persists, as287,000 women lost their lives to pregnancy and childbirth related causes in 2010. Almost all of these deaths were preventable and occurred in low-resource settings, pointing towards dearth of adequate facilities in these parts of the world. The main objective of this paper is to review the evidence based childbirth and post natal interventions which have a beneficial impact on maternal and newborn outcomes. It is a compilation of existing, new and updated interventions designed to help physicians and policy makers and enable them to reduce the burden of maternal and neonatal morbidities and mortalities. Interventions during the post natal period that were found to be associated with a decrease in maternal and neonatal morbidity and mortality included: advice and support of family planning, support and promotion of early initiation and continued breastfeeding; thermal care or kangaroo mother care for preterm and/or low birth weight babies; hygienic care of umbilical cord and skin following delivery, training health personnel in basic neonatal resuscitation; and postnatal visits. Adequate delivery of these interventions is likely to bring an unprecedented decrease in the number of deaths reported during childbirth. PMID:25177795
Kun, Sheila S; Beas, Virginia N; Keens, Thomas G; Ward, Sally S L; Gold, Jeffrey I
2015-07-01
To assess the pediatric home health nurses' knowledge in tracheostomy and ventilator emergency care on home mechanical ventilation (HMV). Emergencies are frightening experiences for solo home health nurses and require advanced skills in emergency response and care, especially in pediatric patients who pose unique challenges. Nurses with greater years of nursing experience would perform better on emergency HMV case-based scenarios than nurses with less years of experience. An exploratory online survey was used to evaluate emergency case-based pediatric scenarios. Demographic and professional experiences were profiled. Seventy-nine nurses had an average of 6.73 (SD = 1.41) years in pediatric nursing. Over 70% received their HMV training in their agency, 41% had less than 4 years of experience, and 30.4% had encountered at least one emergency situation at home. The online survey was distributed by managers of 22 home health agencies to nurses providing pediatric HMV care. Nurses scored an average of 4.87 out of 10 possible points. There were no significant differences between nurses with <4 years of experience versus those with more experience on ventilator alarms knowledge or total knowledge. Ninety-seven percent of the nurses favored more training in HMV from a variety of settings (e.g., agency, on-line training). Nurses did not perform well in case-based ventilator alarm scenarios. Length of nursing experience did not differentiate greater knowledge. It is clear that nurses require and want more training in emergency-based HMV. Recommendations for an enhanced curriculum are suggested. © 2014 Wiley Periodicals, Inc.
Controlled trial of standard pad and bell alarm against mini alarm for nocturnal enuresis.
Fordham, K E; Meadow, S R
1989-01-01
Fifty six children aged from 6-16 years who wet their beds at night were entered into a controlled trial of two alarm devices: a traditional alarm using a wet sensor mat on the bed attached to an alarm bell out of reach of the child, and a mini alarm system incorporating a tiny perineal wet sensor attached to a small alarm worn on the child's clothing. A quota allocation system ensured comparability between the two treatment groups. The children were encouraged to use the alarm for four months. Both alarms were equally effective in helping children to become dry. There was no significant difference between the number of children unable to comply with treatment or to be helped by each alarm. The rate of acquisition of dryness was similar for the two groups. The traditional standard alarm was sturdier, more dependable, and easier to maintain, but the mini alarm had some advantages, particularly for girls. Both types of alarm are recommended for general use. Images Fig 1 Fig 2 PMID:2658853
The robustness of false memory for emotional pictures.
Bessette-Symons, Brandy A
2018-02-01
Emotional material is commonly reported to be more accurately recognised; however, there is substantial evidence of increased false alarm rates (FAR) for emotional material and several reports of stronger influences on response bias than accuracy. This pattern is more frequently reported for words than pictures. Research on the mechanisms underlying bias differences has mostly focused on word lists under short retention intervals. This article presents four series of experiments examining recognition memory for emotional pictures while varying arousal and the control over the content of the pictures at two retention intervals, and one study measuring the relatedness of the series picture sets. Under the shorter retention interval, emotion increased false alarms and reduced accuracy. Under the longer retention interval emotion increased hit rates and FAR, resulting in reduced accuracy and/or bias. At both retention intervals, the pattern of valence effects differed based on the arousal associated with the picture sets. Emotional pictures were found to be more related than neutral pictures in each set; however, the influence of relatedness alone does not provide an adequate explanation for all emotional differences. The results demonstrate substantial emotional differences in picture recognition that vary based on valence, arousal and retention interval.
McCoy, Mary A; Roper, Carey; Campa, Emily; Stephens-Stidham, Shelli; Carlin, Debra K; Istre, Gregory R
2014-04-01
To assess the functionality of lithium-powered smoke alarms that had been installed through a community-based programme called Operation Installation (OI). A random sample was chosen of homes that had received smoke alarms through OI, 2, 4, 6, 8 and 10 years previously. Sampled homes were visited, and information collected included functional status of smoke alarms. For homes in the 6-, 8- and 10-year sample, smoke alarms were removed and tested for battery and alarm function. 800 homes were included in the survey results; 1884 smoke alarms had been installed through OI. The proportion of homes that had at least one functioning OI smoke alarm ranged from 91.8% for year 2 sample to 19.8% for year 10. Of the originally installed smoke alarms in year 10 sample, 45.5% had been removed and 59% (64/108) of those that were still installed were not functioning. Multivariate analysis showed that the presence of at least one working alarm in the home was associated positively with the number of smoke alarms that were originally installed and whether the original occupant was still living in the home, and negatively with the length of time since the smoke alarm was installed, and whether there was a smoker in the home. Testing of the smoke alarms revealed that most non-functioning alarms had missing or dead batteries. Less than a quarter of the originally installed smoke alarms were still present and functioning by year 10. These findings have important implications for smoke alarm installation programmes.
28. SONAR CONTROL ROOM FORWARD LOOKING AFT SHOWING AN/SQS23G ...
28. SONAR CONTROL ROOM - FORWARD LOOKING AFT SHOWING AN/SQS-23G DETECTING-RANGING SET, MARK & CONTROL PANEL, CAN-55134 RECORDER, SPEED INDICATOR, VARIOUS ALARMS AND INTERNAL COMMUNICATION CIRCUITS. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA
DOE Office of Scientific and Technical Information (OSTI.GOV)
SMITH, S.G.
1999-10-21
The following Acceptance Test Procedure was written to test the ENRAF series 854 ATG with SPU II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and alarms functionality.
Perspectives on Pap Test Follow Up Care Among Rural Appalachian Women
Schoenberg, Nancy; Baltisberger, Julie; Bardach, Shoshana; Dignan, Mark
2010-01-01
Approximately one to three quarters of women notified of abnormal Pap test results do not receive appropriate follow up care, dramatically elevating their risk for invasive cervical cancer (ICC). We explored barriers to/facilitators of follow up care for women in two counties in Appalachian Kentucky, where ICC incidence and mortality are significantly higher than the national average. In-depth interviews were conducted among 27 Appalachian women and seven local health department personnel. Those who had been told of an atypical Pap test result tended to have one of three reactions; (1) not alarmed and generally did not obtain follow-up care; (2) alarmed and obtained follow up care; or (3) alarmed, but did not obtain care. Each of these typologies appeared to be shaped by a differing set of three categories of influences: personal factors; procedure/provider/system factors; and ecological/community factors. Recommendations to increase appropriate follow up care included pursuing research on explanations for these typologies and developing tailored interventions specific to women in each of the response types. PMID:20981638
NASA Technical Reports Server (NTRS)
Sandor, A.; Moses, H. R.
2016-01-01
Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were asked to identify the alert as quickly and as accurately as possible. Reaction time and accuracy were measured. Participants identified speech alerts significantly faster than tone alerts. The HERA study investigated the performance of participants in a flight-like environment. Participants were instructed to complete items on a task list and respond to C&W alerts as they occurred. Reaction time and accuracy were measured to determine if the benefits of speech alarms are still present in an applied setting.
Reducing SCADA System Nuisance Alarms in the Water Industry in Northern Ireland.
O'Donoghue, Nigel; Phillips, Debra H; Nicell, Ciaran
2015-08-01
The advancement of telemetry control for the water industry has increased the difficulty of managing large volumes of nuisance alarms (i.e., alarms that do not require a response). The aim of this study was to identify and reduce the number of nuisance alarms that occur for Northern Ireland (NI) Water by carrying out alarm duration analysis to determine the appropriate length of persistence (an advanced alarm management tool) that could be applied. All data were extracted from TelemWeb (NI Water's telemetry monitoring system) and analyzed in Excel. Over a 6-week period, an average of 40 000 alarms occurred per week. The alarm duration analysis, which has never been implemented before by NI Water, found that an average of 57% of NI Water alarms had a duration of <5 minutes. Applying 5-minute persistence, therefore, could prevent an average 26 816 nuisance alarms per week. Most of these alarms were from wastewater assets.
Fault Diagnosis with Multi-State Alarms in a Nuclear Power Control Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuart A. Ragsdale; Roger Lew; Ronald L. Boring
2014-09-01
This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effects of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized the use of three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. Sensitivity and criterion based on the Signal Detection Theory were used to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed bettermore » and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.« less
Evaluation of fire-safety programs that use 10-year smoke alarms.
Jackson, Mark; Wilson, Jonathan; Akoto, Judith; Dixon, Sherry; Jacobs, David E; Ballesteros, Michael F
2010-10-01
The Centers for Disease Control and Prevention began funding a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in 1998. This program involves the installation of lithium-powered "10-year" smoke alarms in homes at high risk for fires and injuries. This study aimed to (1) determine among original SAIFE homes if the lithium-powered alarms were still present and functional 8-10 years after installation and (2) understand factors related to smoke alarm presence and functionality. Data on a total of 384 homes and 601 smoke alarms in five states were collected and analyzed. Only one-third of alarms were still functional; 37% of installed alarms were missing; and 30% of alarms were present, but not functioning. Alarms were less likely to be functioning if they were installed in the kitchen and if homes had a different resident at follow-up. Of the 351 alarms that were present and had a battery at the time of the evaluation, only 21% contained lithium-powered batteries. Of these, 78% were still functioning. Programs that install lithium-powered alarms should use units that have sealed-in batteries and "hush" buttons. Additionally, education should be given on smoke alarm maintenance that includes a message that batteries in these alarms should not be replaced. Lithium-powered smoke alarms should last up to 10 years if maintained properly.
Winters, Bradford D; Cvach, Maria M; Bonafide, Christopher P; Hu, Xiao; Konkani, Avinash; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; Pelter, Michele M; McLean, Barbara; Kane-Gill, Sandra L
2018-01-01
Alarm fatigue is a widely recognized safety and quality problem where exposure to high rates of clinical alarms results in desensitization leading to dismissal of or slowed response to alarms. Nonactionable alarms are thought to be especially problematic. Despite these concerns, the number of clinical alarm signals has been increasing as an everincreasing number of medical technologies are added to the clinical care environment. PubMed, SCOPUS, Embase, and CINAHL. We performed a systematic review of the literature focused on clinical alarms. We asked a primary key question; "what interventions have been attempted and resulted in the success of reducing alarm fatigue?" and 3-secondary key questions; "what are the negative effects on patients/families; what are the balancing outcomes (unintended consequences of interventions); and what human factor approaches apply to making an effective alarm?" Articles relevant to the Key Questions were selected through an iterative review process and relevant data was extracted using a standardized tool. We found 62 articles that had relevant and usable data for at least one key question. We found that no study used/developed a clear definition of "alarm fatigue." For our primary key question 1, the relevant studies focused on three main areas: quality improvement/bundled activities; intervention comparisons; and analysis of algorithm-based false and total alarm suppression. All sought to reduce the number of total alarms and/or false alarms to improve the positive predictive value. Most studies were successful to varying degrees. None measured alarm fatigue directly. There is no agreed upon valid metric(s) for alarm fatigue, and the current methods are mostly indirect. Assuming that reducing the number of alarms and/or improving positive predictive value can reduce alarm fatigue, there are promising avenues to address patient safety and quality problem. Further investment is warranted not only in interventions that may reduce alarm fatigue but also in defining how to best measure it.
Objective Analysis of Oceanic Data for Coast Guard Trajectory Models Phase II
1997-12-01
as outliers depends on the desired probability of false alarm, Pfa values, which is the probability of marking a valid point as an outlier. Table 2-2...constructed to minimize the mean-squared prediction error of the grid point estimate under the constraint that the estimate is unbiased . The...prediction error, e= Zl(S) _oizl(Si)+oC1iZz(S) (2.44) subject to the constraints of unbiasedness , • c/1 = 1,and (2.45) i SCC12 = 0. (2.46) Denoting
Smith, Gary A; Splaingard, Mark; Hayes, John R; Xiang, Huiyun
2006-10-01
Conventional residential tone smoke alarms fail to awaken the majority of children during slow wave sleep. With the objective of identifying a more effective smoke alarm for children, we compared a personalized parent voice smoke alarm with a conventional residential tone smoke alarm, both presented at 100 dB, with respect to their ability to awaken children 6- to 12-years-old from stage 4 sleep and prompt their performance of a simulated self-rescue escape procedure. Using a randomized, nonblinded, clinical research design, a volunteer sample of healthy children 6- to 12-years-old was enrolled in the study. Children were trained how to perform a simulated self-rescue escape procedure when they heard a smoke alarm. Each child's mother recorded a voice alarm message, "First name! First name! Wake up! Get out of bed! Leave the room!" For each child, either the voice or tone smoke alarm was randomly selected and triggered during the first cycle of stage 4 sleep, and then the other alarm was triggered during the second cycle of stage 4 sleep. Children's sleep stage was monitored by electroencephalography, electro-oculography, and chin electromyography. The 4 main outcome measures included the number of children who awakened, the number of children who escaped, the time to awakening, and the time to escape. Twenty-four children were enrolled. The median age was 9 years, and 11 (46%) were boys. One half of the children received the parent voice alarm first, and one half received the tone alarm first; however, the order that the alarm stimuli were presented was not statistically associated with awakening or escaping. Twenty-three (96%) of the 24 subjects awakened to the parent voice alarm compared with 14 (58%) to the tone alarm. One child did not awaken to either stimulus. Nine children awakened to their parent's voice but not to the tone, whereas none awakened to only the tone and not the voice. Twenty (83%) of the subjects in the parent voice alarm group successfully performed the escape procedure within 5 minutes of alarm onset compared with 9 (38%) in the tone alarm group. The median time to awaken was 20 seconds in the voice alarm group compared with 3 minutes in the tone alarm group. The median time to escape was 38 seconds in the voice alarm group compared with the maximum allowed 5 minutes in the tone alarm group. When exposed to the tone alarm, older children were more likely to awaken and were more likely to escape than younger children. There was no association between child's age and awakening or escaping for children exposed to the parent voice alarm. There was no association between child's gender and awakening or escaping for either alarm type. To our knowledge, this study is the first to compare the ability of different types of smoke alarms to awaken children while monitoring sleep stage. The personalized parent voice smoke alarm at 100 dB successfully awakened 96% of children 6- to 12-years-old from stage 4 sleep with 83% successfully performing a simulated self-rescue escape procedure, significantly outperforming the 100-dB conventional residential tone smoke alarm. These findings suggest a clear direction for future research, as well as important fundamental changes in smoke alarm design, that address the unique developmental needs of children. The development of a more effective smoke alarm for use in homes and other locations where children sleep provides an opportunity to reduce fire-related morbidity and mortality among children.
Orr, Stanley G.
2000-01-01
A hardwired, fail-safe rack protection monitor utilizes electromechanical relays to respond to the detection by condition sensors of abnormal or alarm conditions (such as smoke, temperature, wind or water) that might adversely affect or damage equipment being protected. When the monitor is reset, the monitor is in a detection mode with first and second alarm relay coils energized. If one of the condition sensors detects an abnormal condition, the first alarm relay coil will be de-energized, but the second alarm relay coil will remain energized. This results in both a visual and an audible alarm being activated. If a second alarm condition is detected by another one of the condition sensors while the first condition sensor is still detecting the first alarm condition, both the first alarm relay coil and the second alarm relay coil will be de-energized. With both the first and second alarm relay coils de-energized, both a visual and an audible alarm will be activated. In addition, power to the protected equipment will be terminated and an alarm signal will be transmitted to an alarm central control. The monitor can be housed in a separate enclosure so as to provide an interface between a power supply for the protected equipment and the protected equipment.
Spiny lobsters detect conspecific blood-borne alarm cues exclusively through olfactory sensilla.
Shabani, Shkelzen; Kamio, Michiya; Derby, Charles D
2008-08-01
When attacked by predators, diverse animals actively or passively release molecules that evoke alarm and related anti-predatory behavior by nearby conspecifics. The actively released molecules are alarm pheromones, whereas the passively released molecules are alarm cues. For example, many insects have alarm-signaling systems that involve active release of alarm pheromones from specialized glands and detection of these signals using specific sensors. Many crustaceans passively release alarm cues, but the nature of the cues, sensors and responses is poorly characterized. Here we show in laboratory and field experiments that injured Caribbean spiny lobsters, Panulirus argus, passively release alarm cues via blood (hemolymph) that induce alarm responses in the form of avoidance and suppression of feeding. These cues are detected exclusively through specific olfactory chemosensors, the aesthetasc sensilla. The alarm cues for Caribbean spiny lobsters are not unique to the species but do show some phylogenetic specificity: P. argus responds primarily with alarm behavior to conspecific blood, but with mixed alarm and appetitive behaviors to blood from the congener Panulirus interruptus, or with appetitive behaviors to blood from the blue crab Callinectes sapidus. This study lays the foundation for future neuroethological studies of alarm cue systems in this and other decapod crustaceans.
Airport detectors and orthopaedic implants.
van der Wal, Bart C H; Grimm, Bernd; Heyligers, Ide C
2005-08-01
As a result of the rising threats of terrorism, airport security has become a major issue. Patients with orthopaedic implants are concerned that they may activate alarms at airport security gates. A literature overview showed that the activation rate of the alarm by hand-held detectors is higher than for arch detectors (100% versus 56%). Arch detection rate has significantly increased from 0% before 1995 up to 83.3% after 1994. Reported factors which influence detection rates are implant mass, implant combinations, implant volume, transfer speed, side of implant, detector model, sensitivity settings, material and tissue masking. Detection rate has been improved by more sensitive devices and improved filter software. Doctors should be able to objectively inform patients. A form is presented which will easily inform the airport security staff.
Sidman, Elanor A; Grossman, David C; Mueller, Beth A
2011-08-01
The objectives of this study are to estimate smoke alarm coverage and adherence with national guidelines in low- to mid-value owner-occupied residences, and to identify resident demographic, behavioral, and building characteristics and other fire and burn safety practices associated with smoke alarm utilization. Baseline visits were conducted with 779 households in King County, Washington, for a randomized trial of smoke alarm functionality. Presence, functionality, features, and location of pre-existing smoke alarms were ascertained by staff observation and testing. Household and building descriptors were collected using questionnaires. Households were classified by presence of smoke alarms, functional alarms, and functional and properly mounted alarms placed in hallways and on each floor but not in recommended avoidance locations. Smoke alarms were present in 89%, and functional units in 78%, of households. Only 6-38% met all assessed functionality and placement recommendations. Homes frequently lacked alarms in any bedrooms or on each floor. Building age, but not renovation status, was associated with all dimensions of smoke alarm coverage; post-1980 constructions were 1.7 times more likely to comply with placement recommendations than were pre-1941 homes (95% CI: 1.1-2.6). Respondent education and race/ethnicity, children <5 years, residency duration, number of floors, wood stoves and fireplaces, number of smoke alarms, recency of smoke alarm testing, carbon monoxide monitors, and fire ladders displayed varying relationships with alarm presence, functionality, and placement. Strategies for maintaining smoke alarms in functional condition and improving compliance with placement recommendations are necessary to achieve universal coverage, and will benefit the majority of households.
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...
Nurses' Perceptions and Practices Related to Alarm Management: A Quality Improvement Initiative.
Cameron, Hannah L; Little, Barbara
2018-05-01
The purpose of this quality improvement project was to develop, implement, and assess the effects of an alarm management policy and educational program on nurses' perceptions and practices of alarm management in an acute care hospital. Nurses from an acute care hospital in the southeastern United States attended a mandatory alarm management education program. The hospital implemented the evidence-based alarm management education to achieve the NPSG.06.01.01: Alarm Management. Pre- and posttests were administered to evaluate the education and the changes in nurses' perceptions and practices of clinical alarms. A total of 417 nurses received the educational intervention. All participants completed the pretest, and 215 (51%) completed the voluntary posttest. Significant improvements were made in alarm perceptions and practices. Nurses suggested unit-specific alarm education, improved staffing, and updated equipment. Findings support the benefits of continued education in alarm management for nurses. Bedside nurses are a critical member of a multidisciplinary alarm management team because they are at the forefront of patient safety and most at risk for experiencing alarm fatigue. J Contin Educ Nurs. 2018;49(5):207-215. Copyright 2018, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Nguyen, Minh Q.; Allebach, Jan P.
2015-01-01
In our previous work1 , we presented a block-based technique to analyze printed page uniformity both visually and metrically. The features learned from the models were then employed in a Support Vector Machine (SVM) framework to classify the pages into one of the two categories of acceptable and unacceptable quality. In this paper, we introduce a set of tools for machine learning in the assessment of printed page uniformity. This work is primarily targeted to the printing industry, specifically the ubiquitous laser, electrophotographic printer. We use features that are well-correlated with the rankings of expert observers to develop a novel machine learning framework that allows one to achieve the minimum "false alarm" rate, subject to a chosen "miss" rate. Surprisingly, most of the research that has been conducted on machine learning does not consider this framework. During the process of developing a new product, test engineers will print hundreds of test pages, which can be scanned and then analyzed by an autonomous algorithm. Among these pages, most may be of acceptable quality. The objective is to find the ones that are not. These will provide critically important information to systems designers, regarding issues that need to be addressed in improving the printer design. A "miss" is defined to be a page that is not of acceptable quality to an expert observer that the prediction algorithm declares to be a "pass". Misses are a serious problem, since they represent problems that will not be seen by the systems designers. On the other hand, "false alarms" correspond to pages that an expert observer would declare to be of acceptable quality, but which are flagged by the prediction algorithm as "fails". In a typical printer testing and development scenario, such pages would be examined by an expert, and found to be of acceptable quality after all. "False alarm" pages result in extra pages to be examined by expert observers, which increases labor cost. But "false alarms" are not nearly as catastrophic as "misses", which represent potentially serious problems that are never seen by the systems developers. This scenario motivates us to develop a machine learning framework that will achieve the minimum "false alarm" rate subject to a specified "miss" rate. In order to construct such a set of receiver operating characteristic2 (ROC) curves, we examine various tools for the prediction, ranging from an exhaustive search over the space of the nonlinear discriminants to a Cost-Sentitive SVM3 framework. We then compare the curves gained from those methods. Our work shows promise for applying a standard framework to obtain a full ROC curve when it comes to tackling other machine learning problems in industry.
Developing a Campus-Wide Print Strategy: A Call for Consistency.
ERIC Educational Resources Information Center
Hawkins, Brian L.
1989-01-01
The advent of microcomputers, laser printers, FAX machines, and desktop publishing has brought about an alarming increase in the amount and variation of printing. Coordination between service units is essential to create a coherent set of print choices, pricing options, and policies for the campus as a whole. (MLW)
Correlation between Identification Accuracy and Response Confidence for Common Environmental Sounds
set of environmental sounds with stimulus control and precision. The present study is one in a series of efforts to provide a baseline evaluation of a...sounds from six broad categories: household items, alarms, animals, human generated, mechanical, and vehicle sounds. Each sound was presented five times
Protect Your Health as You Grow Older
... smoke alarms if possible. These alarms use lithium batteries and last longer than regular smoke alarms. They ... If you use regular smoke alarms, replace the batteries every year. (Tip: Change smoke alarm batteries when ...
Smoke alarm and battery function 42 months after installation: a randomized trial.
Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Jones, Michael P; Young, Tracy; Zwerling, Craig
2010-10-01
This randomized trial presents findings from the longest follow-up study of smoke alarm and battery function to date. The purpose of this study is to examine differences in long-term function of smoke alarm and battery combinations. A total of 691 households in an ongoing cohort study were randomly allocated into smoke alarm groups of ionizing and photoelectric and battery groups of zinc and lithium. Smoke alarm function was measured in 633 (91.6%) households from January 2007 through February 2008, 42 months following original smoke alarm/battery installation. Data analyses were conducted in 2009. After 3.5 years, 81.9% of the 1898 smoke alarms were functional. Ionizing alarms with zinc batteries were the least likely to function (72.7%). In comparison, photoelectric alarms with lithium batteries were 2.9 times (95% CI=1.8, 4.5) more likely to function; ionizing alarms with lithium batteries were 2.0 times (95% CI=1.3, 3.1) more likely to function; and photoelectric alarms with zinc batteries were 1.7 times (95% CI=1.1, 2.5) more likely to function. Functionality was strongly tied to number of reports of nuisance alarms, which was higher for ionizing than photoelectric alarms. Photoelectric smoke alarms and lithium batteries are the most likely to function long after smoke alarm installation, and may be worthwhile investments despite their increased cost. Copyright © 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Nässelqvist, Mattias; Gustavsson, Rolf; Aidanpää, Jan-Olov
2013-07-01
It is important to monitor the radial loads in hydropower units in order to protect the machine from harmful radial loads. Existing recommendations in the standards regarding the radial movements of the shaft and bearing housing in hydropower units, ISO-7919-5 (International Organization for Standardization, 2005, "ISO 7919-5: Mechanical Vibration-Evaluation of Machine Vibration by Measurements on Rotating Shafts-Part 5: Machine Sets in Hydraulic Power Generating and Pumping Plants," Geneva, Switzerland) and ISO-10816-5 (International Organization for Standardization, 2000, "ISO 10816-5: Mechanical Vibration-Evaluation of Machine Vibration by Measurements on Non-Rotating Parts-Part 5: Machine Sets in Hydraulic Power Generating and Pumping Plants," Geneva, Switzerland), have alarm levels based on statistical data and do not consider the mechanical properties of the machine. The synchronous speed of the unit determines the maximum recommended shaft displacement and housing acceleration, according to these standards. This paper presents a methodology for the alarm and trip levels based on the design criteria of the hydropower unit and the measured radial loads in the machine during operation. When a hydropower unit is designed, one of its design criteria is to withstand certain loads spectra without the occurrence of fatigue in the mechanical components. These calculated limits for fatigue are used to set limits for the maximum radial loads allowed in the machine before it shuts down in order to protect itself from damage due to high radial loads. Radial loads in hydropower units are caused by unbalance, shape deviations, dynamic flow properties in the turbine, etc. Standards exist for balancing and manufacturers (and power plant owners) have recommendations for maximum allowed shape deviations in generators. These standards and recommendations determine which loads, at a maximum, should be allowed before an alarm is sent that the machine needs maintenance. The radial bearing load can be determined using load cells, bearing properties multiplied by shaft displacement, or bearing bracket stiffness multiplied by housing compression or movement. Different load measurement methods should be used depending on the design of the machine and accuracy demands in the load measurement. The methodology presented in the paper is applied to a 40 MW hydropower unit; suggestions are presented for the alarm and trip levels for the machine based on the mechanical properties and radial loads.
Roberts, Kristin J; Fowler, Erica; Comstock, R Dawn; Fernandez, Soledad; Abdel-Rasoul, Mahmoud; Mihalov, Leslie; Casavant, Marcel J; McKenzie, Lara B
2018-02-01
Although the proper installation and maintenance of carbon monoxide (CO) and smoke alarms can protect individuals from residential CO-related and fire-related injuries, these devices are underutilized. We describe characteristics associated with self-reported CO and smoke alarm use of parents recruited from a pediatric emergency department to improve CO alarm use. Parents of children ≤ 18 years (N = 299) reported socio-demographic characteristics and CO and smoke alarm ownership and practices. We assigned participants to a behavioral profile and a Precaution Adoption Process Model stage based on their self-reported CO and smoke alarm use. Most participants (71%) did not have CO alarms in their homes, but reported owning at least one working smoke alarm (98%). Participants who reported "perfect" CO alarm behavior (defined as having a working CO alarm, one near a sleeping area, with batteries replaced every 6 months; 9%) were more likely to earn a higher income, own their home, and have lived at their current residence for at least 2 years. Participants who reported "perfect" smoke alarm behavior (defined as having a working smoke alarm on every level, with batteries replaced every 6 months; 49%) were more likely to rent their home, receive federal assistance, and have lived at their current residence for at least 2 years. Interventions to increase correct CO alarm use are necessary.
Frame synchronization methods based on channel symbol measurements
NASA Technical Reports Server (NTRS)
Dolinar, S.; Cheung, K.-M.
1989-01-01
The current DSN frame synchronization procedure is based on monitoring the decoded bit stream for the appearance of a sync marker sequence that is transmitted once every data frame. The possibility of obtaining frame synchronization by processing the raw received channel symbols rather than the decoded bits is explored. Performance results are derived for three channel symbol sync methods, and these are compared with results for decoded bit sync methods reported elsewhere. It is shown that each class of methods has advantages or disadvantages under different assumptions on the frame length, the global acquisition strategy, and the desired measure of acquisition timeliness. It is shown that the sync statistics based on decoded bits are superior to the statistics based on channel symbols, if the desired operating region utilizes a probability of miss many orders of magnitude higher than the probability of false alarm. This operating point is applicable for very large frame lengths and minimal frame-to-frame verification strategy. On the other hand, the statistics based on channel symbols are superior if the desired operating point has a miss probability only a few orders of magnitude greater than the false alarm probability. This happens for small frames or when frame-to-frame verifications are required.
Fast Vessel Detection in Gaofen-3 SAR Images with Ultrafine Strip-Map Mode
Liu, Lei; Qiu, Xiaolan; Lei, Bin
2017-01-01
This study aims to detect vessels with lengths ranging from about 70 to 300 m, in Gaofen-3 (GF-3) SAR images with ultrafine strip-map (UFS) mode as fast as possible. Based on the analysis of the characteristics of vessels in GF-3 SAR imagery, an effective vessel detection method is proposed in this paper. Firstly, the iterative constant false alarm rate (CFAR) method is employed to detect the potential ship pixels. Secondly, the mean-shift operation is applied on each potential ship pixel to identify the candidate target region. During the mean-shift process, we maintain a selection matrix recording which pixels can be taken, and these pixels are called as the valid points of the candidate target. The l1 norm regression is used to extract the principal axis and detect the valid points. Finally, two kinds of false alarms, the bright line and the azimuth ambiguity, are removed by comparing the valid area of the candidate target with a pre-defined value and computing the displacement between the true target and the corresponding replicas respectively. Experimental results on three GF-3 SAR images with UFS mode demonstrate the effectiveness and efficiency of the proposed method. PMID:28678197
46 CFR 113.43-3 - Alarm system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...
46 CFR 113.43-3 - Alarm system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...
46 CFR 113.43-3 - Alarm system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...
Increasing smoke alarm operability through theory-based health education: a randomised trial
Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S
2015-01-01
Background Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Methods Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm’s hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005–2008. Followup visits checked alarm operability in 370 homes (85%) 1–3.5 years after installation. Main outcome measures: number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Results Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Conclusions Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. Trial registration number http://www.clinicaltrials.gov number NCT00139126. PMID:25165090
Tracking initially unresolved thrusting objects in 3D using a single stationary optical sensor
NASA Astrophysics Data System (ADS)
Lu, Qin; Bar-Shalom, Yaakov; Willett, Peter; Granström, Karl; Ben-Dov, R.; Milgrom, B.
2017-05-01
This paper considers the problem of estimating the 3D states of a salvo of thrusting/ballistic endo-atmospheric objects using 2D Cartesian measurements from the focal plane array (FPA) of a single fixed optical sensor. Since the initial separations in the FPA are smaller than the resolution of the sensor, this results in merged measurements in the FPA, compounding the usual false-alarm and missed-detection uncertainty. We present a two-step methodology. First, we assume a Wiener process acceleration (WPA) model for the motion of the images of the projectiles in the optical sensor's FPA. We model the merged measurements with increased variance, and thence employ a multi-Bernoulli (MB) filter using the 2D measurements in the FPA. Second, using the set of associated measurements for each confirmed MB track, we formulate a parameter estimation problem, whose maximum likelihood estimate can be obtained via numerical search and can be used for impact point prediction. Simulation results illustrate the performance of the proposed method.
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2014-10-01 2014-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2013-10-01 2013-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2011-10-01 2011-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2012-10-01 2012-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2010-10-01 2010-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
Increasing smoke alarm operability through theory-based health education: a randomised trial.
Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S
2014-12-01
Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm's hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005-2008. Follow-up visits checked alarm operability in 370 homes (85%) 1-3.5 years after installation. number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. http://www.clinicaltrials.gov number NCT00139126. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Cammaerts, Marie-Claire
2014-01-01
Abstract Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants’ ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. PMID:25525102
Maternal depressive symptoms and infant health practices among low-income women.
Chung, Esther K; McCollum, Kelly F; Elo, Irma T; Lee, Helen J; Culhane, Jennifer F
2004-06-01
To determine the relationships between maternal depressive symptoms and the use of infant health services, parenting practices, and injury-prevention measures. A prospective, community-based survey of women attending Philadelphia public health centers between February 2000 and November 2001 was conducted. Women were surveyed at 3 time points before and after parturition. Depressive symptoms were determined with the Center for Epidemiologic Studies Depression Scale at each time point. We studied 6 outcomes, clustered into 3 categories: 1) infant health service use (adequate well-child care and ever being hospitalized); 2) parenting practices (breastfeeding for > or =1 month and use of corporal punishment); and 3) injury-prevention measures (having a smoke alarm and using the back sleep position). The sample consisted of 774 largely single (74%), uninsured (63%), African American (65%) women, with a mean age of 24 +/- 6 years and a mean annual income of 8063 dollars. Forty-eight percent of women had depressive symptoms at 1 or 2 time points (ever symptoms) and 12% had depressive symptoms at all points (persistent symptoms). Compared with women who never had depressive symptoms (without symptoms), women with persistent symptoms were nearly 3 times as likely to have their child ever hospitalized (adjusted odds ratio: 2.89; 95% confidence interval: 1.61-5.07) and twice as likely to use corporal punishment (adjusted odds ratio: 1.90; 95% confidence interval: 1.08-3.34). Mothers with persistent depressive symptoms were nearly three-quarters less likely to have smoke alarms in their homes (adjusted odds ratio: 0.28; 95% confidence interval: 0.11-0.70) and one-half as likely to use the back sleep position (adjusted odds ratio: 0.56; 95% confidence interval: 0.35-0.91), compared with women without symptoms. There was no association between maternal depressive symptoms and infant receipt of well-child care or the likelihood of breastfeeding for > or =1 month. Maternal depressive symptoms persisting from the prepartum to postpartum periods were associated with increased risks of infant hospitalization and use of corporal punishment and with lower likelihood of having a smoke alarm and using the back sleep position. Additional efforts are needed to identify and evaluate mothers with depressive symptoms to improve the health and safety of young infants.
Patient characteristics associated with false arrhythmia alarms in intensive care.
Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao
2017-01-01
A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients' annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years ( P =0.013; P =0.034), confused mental status ( P <0.001 for both comparisons), cardiovascular diagnoses ( P <0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) ( P =0.003; P =0.004) or ventricular paced rhythm ( P =0.002 for both comparisons), respiratory diagnoses ( P =0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones ( P <0.001 for both comparisons). Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management.
Wang, Xiaolin; Ioacara, Sorin; DeHennis, Andrew
2015-11-01
This study analyzed the overall nocturnal performance during home use of a long-term subcutaneous implantable continuous glucose monitoring (CGM) sensor. In this study, 12 subjects with type 1 diabetes mellitus (T1DM) (mean±SD age, 37±8 years; mean±SD disease duration, 11±6 years) were implanted with an investigational continuous glucose sensor in the upper arm for up to 90 days. All subjects received full access to real-time glucose display and user programmable hypo- and hyperglycemic alarms. Subjects calibrated the sensors with a self-monitoring of blood glucose (SMBG) meter and continued to rely on their regular SMBG measurements for their diabetes management. Accuracy of the sensors during the home-use study was calculated using SMBG as the reference. The nocturnal sensor attenuation (NSA) concept was tested. Sensitivity and specificity of the nocturnal hypoglycemic alarm were calculated. Mean±SD glucose sensor life span was 87±7 days. The mean±SE absolute relative difference over the range of 40-400 mg/dL for the sensors in this home-use study was 12.3±0.7% using SMBG as the reference. The hypoglycemia alarms were set to be triggered when the glucose level went below 70 mg/dL. Percentage of nights with hypoglycemic alarms triggered for at least 10 min was 13.6%. Recovery into euglycemia within 30 min from the timestamp of the immediate confirmatory SMBG testing was obtained in 74% of all episodes (n=20). The implanted continuous glucose sensor showed a hypoglycemia detection sensitivity and specificity of 77% and 96%, respectively. The NSA-associated high negative rate of change of at least -4 mg/dL/min was not encountered during night use of the system. This home-use study of a fully implantable, long-term continuous glucose sensor shows excellent performance in nocturnal hypoglycemia detection in T1DM patients. The apparent lack of NSA affecting the implanted sensor and the high specificity of the hypoglycemic alarm expedite the recovery from nighttime hypoglycemia.
Dual sensitivity mode system for monitoring processes and sensors
Wilks, Alan D.; Wegerich, Stephan W.; Gross, Kenneth C.
2000-01-01
A method and system for analyzing a source of data. The system and method involves initially training a system using a selected data signal, calculating at least two levels of sensitivity using a pattern recognition methodology, activating a first mode of alarm sensitivity to monitor the data source, activating a second mode of alarm sensitivity to monitor the data source and generating a first alarm signal upon the first mode of sensitivity detecting an alarm condition and a second alarm signal upon the second mode of sensitivity detecting an associated alarm condition. The first alarm condition and second alarm condition can be acted upon by an operator and/or analyzed by a specialist or computer program.
Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus).
Deng, Huaiqing; Gao, Kai; Zhou, Jiang
2016-09-30
Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002-2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7-10 min) followed by longer variable-frequency mobbing calls lasting 5-12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520-1000 Hz and 690-3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates' species. The system of vocal alarm behavior described in this critically endangered species is simple and effective.
A cost analysis of a smoke alarm installation and fire safety education program.
Parmer, John E; Corso, Phaedra S; Ballesteros, Michael F
2006-01-01
While smoke alarm installation programs can help prevent residential fire injuries, the costs of running these programs are not well understood. We conducted a retrospective cost analysis of a smoke alarm installation program in 12 funded communities across four states. Costs included financial and economic resources needed for training, canvassing, installing, and following-up, within four cost categories: (a) personnel, (b) transportation, (c) facility, and (d) supplies. Local cost per completed home visit averaged 214.54 dollars, with an average local cost per alarm installed of 115.02 dollars. Combined state and local cost per alarm installed across all four states averaged 132.15 dollars. For every 1% increase in alarm installation, costs per alarm decrease by 1.32 dollars. As more smoke alarms are installed, the average installation cost per alarm decreases. By demonstrating effective economies of scale, this study suggests that smoke alarm programs can be implemented efficiently and receive positive economic returns on investment.
Gender roles for Alice and Bob
NASA Astrophysics Data System (ADS)
Harris, Philip
2013-04-01
As the head of a department that is striving to achieve bronze status under the Athena SWAN (Scientific Women's Academic Network) programme, I have become extremely sensitive to gender stereotyping, and I am afraid that the "Alice and Bob" image on the cover of your March issue on quantum frontiers set off some alarm bells.
Cocaine, Glamorous Status Symbol of the 'Jet Set,' Is Fast Becoming Many Students' Drug of Choice.
ERIC Educational Resources Information Center
Greene, Elizabeth
1985-01-01
Cocaine, the highly addictive substance, is being used by alarming numbers of undergraduates, and many are selling it on their campuses to support their own habits. A questionnaire for students who might be in trouble with cocaine and don't know it is provided. (MLW)
What Can We Do to Strengthen the Teacher Workforce?
ERIC Educational Resources Information Center
Gorard, Stephen; See, Beng Huat; Smith, Emma; White, Patrick
2007-01-01
This paper considers recurrent alarms in England, Wales and other developed countries concerning shortages of teachers. It summarises the conclusions from a mixed-methods international study of teacher supply, quality and retention. The research used large-scale secondary data sets from a variety of sources, at both the individual and aggregate…
Something Every Teacher and Counselor Needs to Know about African-American Children
ERIC Educational Resources Information Center
Davis, Patrick E.
2007-01-01
African-American student academic performance, as a group, in most educational settings causes alarm to educators, policymakers, and laypeople, alike. Some suggest that the problems associated with the academic under-achievement of many African-American students are perhaps the most pressing issues facing both educators and researchers. Much…
Regulatory Conformance Checking: Logic and Logical Form
ERIC Educational Resources Information Center
Dinesh, Nikhil
2010-01-01
We consider the problem of checking whether an organization conforms to a body of regulation. Conformance is studied in a runtime verification setting. The regulation is translated to a logic, from which we synthesize monitors. The monitors are evaluated as the state of an organization evolves over time, raising an alarm if a violation is…
46 CFR 169.815 - Emergency signals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Emergency signals. 169.815 Section 169.815 Shipping... Operations § 169.815 Emergency signals. (a) The station bill must set forth the various signals used for... vessels of 100 gross tons and over the following signals must be used. (1) The first alarm signal must be...
46 CFR 169.815 - Emergency signals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Emergency signals. 169.815 Section 169.815 Shipping... Operations § 169.815 Emergency signals. (a) The station bill must set forth the various signals used for... vessels of 100 gross tons and over the following signals must be used. (1) The first alarm signal must be...
46 CFR 169.815 - Emergency signals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Emergency signals. 169.815 Section 169.815 Shipping... Operations § 169.815 Emergency signals. (a) The station bill must set forth the various signals used for... vessels of 100 gross tons and over the following signals must be used. (1) The first alarm signal must be...
[Discuss about Alarm Requirements of Standards for Tests of Patient Monitor].
Feng, Ting
This paper introduces the alarm requirements of standards of patient monitor and expounds their significance for tests and guidance for patient monitor, then discusses whether technical alarm should not be closed and it latching alarm and non-latching alarm can not exist together.
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground alarm systems. 57.4360 Section 57...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground alarm systems. 57.4360 Section 57...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground alarm systems. 57.4360 Section 57...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground alarm systems. 57.4360 Section 57...
Alarm acknowledgement in a nuclear plant control room
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
Alarm acknowledgment can be made not only at the alarm tile array of a given console but via other touch sensitive alarm indications in the screen displays of the monitoring system at the same or other consoles; also, touching one tile can acknowledge multiple alarm sources.
Detection with Enhanced Energy Windowing Phase I Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bass, David A.; Enders, Alexander L.
2016-12-01
This document reviews the progress of Phase I of the Detection with Enhanced Energy Windowing (DEEW) project. The DEEW project is the implementation of software incorporating an algorithm which reviews data generated by radiation portal monitors and utilizes advanced and novel techniques for detecting radiological and fissile material while not alarming on Naturally Occurring Radioactive Material. Independent testing indicated that the Enhanced Energy Windowing algorithm showed promise at reducing the probability of alarm in the stream of commerce compared to existing algorithms and other developmental algorithms, while still maintaining adequate sensitivity to threats. This document contains a brief description ofmore » the project, instructions for setting up and running the applications, and guidance to help make reviewing the output files and source code easier.« less
Local ICA for the Most Wanted face recognition
NASA Astrophysics Data System (ADS)
Guan, Xin; Szu, Harold H.; Markowitz, Zvi
2000-04-01
Facial disguises of FBI Most Wanted criminals are inevitable and anticipated in our design of automatic/aided target recognition (ATR) imaging systems. For example, man's facial hairs may hide his mouth and chin but not necessarily the nose and eyes. Sunglasses will cover the eyes but not the nose, mouth, and chins. This fact motivates us to build sets of the independent component analyses bases separately for each facial region of the entire alleged criminal group. Then, given an alleged criminal face, collective votes are obtained from all facial regions in terms of 'yes, no, abstain' and are tallied for a potential alarm. Moreover, and innocent outside shall fall below the alarm threshold and is allowed to pass the checkpoint. Such a PD versus FAR called ROC curve is obtained.
Combating Terrorism Technology Support Office 2006 Review
2006-01-01
emplaced beyond the control point, activated manually or automatically , with warning lights and an audible alarm to alert innocent pedestrians. The...throughout a vehicle. When a tamper event is detected, SERVANT automatically records sensor data and surveillance video and sends an alert to the security...exposure to organophosphate nerve agents, botulinum toxin, cyanide, and carbon monoxide and will be packaged into a portable , lightweight, mobile hand
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 108.627 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next to...
46 CFR 169.732 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...
46 CFR 169.732 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
Building Security. Honeywell Planning Guide.
ERIC Educational Resources Information Center
Honeywell, Inc., Minneapolis, Minn.
A general discussion of building detection and alarm systems to provide security against burglary and vandalism is provided by a manufacturer of automated monitoring and control systems. Security systems are identified as--(1) local alarm system, (2) central station alarm system, (3) proprietary alarm system, and (4) direct connect alarm system..…
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
Alarm Fatigue: Use of an Evidence-Based Alarm Management Strategy.
Turmell, Jacob W; Coke, Lola; Catinella, Rachel; Hosford, Tracy; Majeski, Amy
The purpose of this article is to describe the impact of an evidence-based alarm management strategy on patient safety. An alarm management program reduced alarms up to 30%. Evaluation of patients on continuous cardiac monitoring showed a 3.5% decrease in census. This alarm management strategy has the potential to save $136 500 and 841 hours of registered nurses' time per year. No patient harm occurred during the 2-year project.
Hornbills can distinguish between primate alarm calls.
Rainey, Hugo J.; Zuberbühler, Klaus; Slater, Peter J. B.
2004-01-01
Some mammals distinguish between and respond appropriately to the alarm calls of other mammal and bird species. However, the ability of birds to distinguish between mammal alarm calls has not been investigated. Diana monkeys (Cercopithecus diana) produce different alarm calls to two predators: crowned eagles (Stephanoaetus coronatus) and leopards (Panthera pardus). Yellow-casqued hornbills (Ceratogymna elata) are vulnerable to predation by crowned eagles but are not preyed on by leopards and might therefore be expected to respond to the Diana monkey eagle alarm call but not to the leopard alarm call. We compared responses of hornbills to playback of eagle shrieks, leopard growls, Diana monkey eagle alarm calls and Diana monkey leopard alarm calls and found that they distinguished appropriately between the two predator vocalizations as well as between the two Diana monkey alarm calls. We discuss possible mechanisms leading to these responses. PMID:15209110
Development and experimental evaluation of an alarm concept for an integrated surgical workstation.
Zeißig, Eva-Maria; Janß, Armin; Dell'Anna-Pudlik, Jasmin; Ziefle, Martina; Radermacher, Klaus
2016-04-01
Alarm conditions of the technical equipment in operating rooms represent a prevalent cause for interruptions of surgeons and scrub nurses, resulting in an increase of workload and potential reduction of patient safety. In this work, an alarm concept for an integrated operating room system based on open communication standards is developed and tested. In a laboratory experiment, the reactions of surgeons were analysed, comparing the displaying of alarms on an integrated workstation and on single devices: disruptive effects of alarm handling on primary task (ratings of perceived distraction, resumption lag, deterioration of speed, accuracy, and prospective memory), efficiency and effectiveness of identification of alarms, as well as perceived workload were included. The identification of the alarm cause is significantly more efficient and effective with the integrated alarm concept. Moreover, a slightly lower deterioration of performance of the primary task due to the interruption of alarm handling was observed. Displaying alarms on an integrated workstation supports alarm handling and consequently reduces disruptive effects on the primary task. The findings show that even small changes can reduce workload in a complex work environment like the operating room, resulting in improved patient safety.
Cammaerts, Marie-Claire
2014-01-01
Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants' ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.
Patient characteristics associated with false arrhythmia alarms in intensive care
Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao
2017-01-01
Introduction A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. Results A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients’ annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years (P=0.013; P=0.034), confused mental status (P<0.001 for both comparisons), cardiovascular diagnoses (P<0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) (P=0.003; P=0.004) or ventricular paced rhythm (P=0.002 for both comparisons), respiratory diagnoses (P=0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones (P<0.001 for both comparisons). Conclusion Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management. PMID:28458554
NASA Astrophysics Data System (ADS)
Knox, H. A.; Draelos, T.; Young, C. J.; Lawry, B.; Chael, E. P.; Faust, A.; Peterson, M. G.
2015-12-01
The quality of automatic detections from seismic sensor networks depends on a large number of data processing parameters that interact in complex ways. The largely manual process of identifying effective parameters is painstaking and does not guarantee that the resulting controls are the optimal configuration settings. Yet, achieving superior automatic detection of seismic events is closely related to these parameters. We present an automated sensor tuning (AST) system that learns near-optimal parameter settings for each event type using neuro-dynamic programming (reinforcement learning) trained with historic data. AST learns to test the raw signal against all event-settings and automatically self-tunes to an emerging event in real-time. The overall goal is to reduce the number of missed legitimate event detections and the number of false event detections. Reducing false alarms early in the seismic pipeline processing will have a significant impact on this goal. Applicable both for existing sensor performance boosting and new sensor deployment, this system provides an important new method to automatically tune complex remote sensing systems. Systems tuned in this way will achieve better performance than is currently possible by manual tuning, and with much less time and effort devoted to the tuning process. With ground truth on detections in seismic waveforms from a network of stations, we show that AST increases the probability of detection while decreasing false alarms.
NASA Astrophysics Data System (ADS)
Tejera, F.; Reyes, A.; Altshuler, E.
2016-07-01
It is well established that danger information can be transmitted by ants through relatively small distances, provoking either a state of alarm when they move away from potentially dangerous stimulus, or charge toward it aggressively. There is almost no knowledge if danger information can be transmitted along large distances. In this paper, we abduct leaf cutting ants of the species Atta insularis while they forage in their natural environment at a certain point of the foraging line, so ants make a "U" turn to escape from the danger zone and go back to the nest. Our results strongly suggest that those ants do not transmit "danger information" to other nestmates marching towards the abduction area. The individualistic behavior of the ants returning from the danger zone results in a depression of the foraging activity due to the systematic sacrifice of non-informed individuals.
Tank Monitoring and Document control System (TMACS) As Built Software Design Document
DOE Office of Scientific and Technical Information (OSTI.GOV)
GLASSCOCK, J.A.
This document describes the software design for the Tank Monitor and Control System (TMACS). This document captures the existing as-built design of TMACS as of November 1999. It will be used as a reference document to the system maintainers who will be maintaining and modifying the TMACS functions as necessary. The heart of the TMACS system is the ''point-processing'' functionality where a sample value is received from the field sensors and the value is analyzed, logged, or alarmed as required. This Software Design Document focuses on the point-processing functions.
An intelligent surveillance platform for large metropolitan areas with dense sensor deployment.
Fernández, Jorge; Calavia, Lorena; Baladrón, Carlos; Aguiar, Javier M; Carro, Belén; Sánchez-Esguevillas, Antonio; Alonso-López, Jesus A; Smilansky, Zeev
2013-06-07
This paper presents an intelligent surveillance platform based on the usage of large numbers of inexpensive sensors designed and developed inside the European Eureka Celtic project HuSIMS. With the aim of maximizing the number of deployable units while keeping monetary and resource/bandwidth costs at a minimum, the surveillance platform is based on the usage of inexpensive visual sensors which apply efficient motion detection and tracking algorithms to transform the video signal in a set of motion parameters. In order to automate the analysis of the myriad of data streams generated by the visual sensors, the platform's control center includes an alarm detection engine which comprises three components applying three different Artificial Intelligence strategies in parallel. These strategies are generic, domain-independent approaches which are able to operate in several domains (traffic surveillance, vandalism prevention, perimeter security, etc.). The architecture is completed with a versatile communication network which facilitates data collection from the visual sensors and alarm and video stream distribution towards the emergency teams. The resulting surveillance system is extremely suitable for its deployment in metropolitan areas, smart cities, and large facilities, mainly because cheap visual sensors and autonomous alarm detection facilitate dense sensor network deployments for wide and detailed coverage.
NASA Astrophysics Data System (ADS)
Vio, R.; Vergès, C.; Andreani, P.
2017-08-01
The matched filter (MF) is one of the most popular and reliable techniques to the detect signals of known structure and amplitude smaller than the level of the contaminating noise. Under the assumption of stationary Gaussian noise, MF maximizes the probability of detection subject to a constant probability of false detection or false alarm (PFA). This property relies upon a priori knowledge of the position of the searched signals, which is usually not available. Recently, it has been shown that when applied in its standard form, MF may severely underestimate the PFA. As a consequence the statistical significance of features that belong to noise is overestimated and the resulting detections are actually spurious. For this reason, an alternative method of computing the PFA has been proposed that is based on the probability density function (PDF) of the peaks of an isotropic Gaussian random field. In this paper we further develop this method. In particular, we discuss the statistical meaning of the PFA and show that, although useful as a preliminary step in a detection procedure, it is not able to quantify the actual reliability of a specific detection. For this reason, a new quantity is introduced called the specific probability of false alarm (SPFA), which is able to carry out this computation. We show how this method works in targeted simulations and apply it to a few interferometric maps taken with the Atacama Large Millimeter/submillimeter Array (ALMA) and the Australia Telescope Compact Array (ATCA). We select a few potential new point sources and assign an accurate detection reliability to these sources.
Randomized controlled trial of ionization and photoelectric smoke alarm functionality.
Mueller, B A; Sidman, E A; Alter, H; Perkins, R; Grossman, D C
2008-04-01
To compare functionality, reasons for non-function, and nuisance alarm levels of two common types of smoke alarms after installation in low- to mid-level income households in King County, Washington. Randomized controlled trial of 761 households. An ionization or photoelectric smoke alarm was installed between June 1, 2000 and July 31, 2002. Main outcome measures were: percentage of study alarms that were working, observed reasons for non-functional status, and self-reported frequency of nuisance alarms at 9 and 15 months of follow-up. At 9 months after installation, 20% of ionization, vs 5% of photoelectric alarms were non-functional, a difference that persisted at 15 months, with the most common reasons for both types being a disconnected or absent battery. The risk ratio for ionization, relative to photoelectric alarms, being non-functional or removed was 2.7 (95% CI 1.8 to 4.1) at 15 months of follow-up. These findings were not altered by educational level, or the presence of smokers, children <5 years, or adults > or =65 years. Burn prevention efforts are geared towards increasing smoke alarm ownership and improving maintenance of functional status. Results suggest that the selective use of photoelectric alarms by fire injury prevention programs or consumers may provide longer-term protection in similar populations. Designing smoke alarms that minimize nuisance alarming may also result in longer term functionality.
Smoke alarm ownership and installation: a comparison of a rural and a suburban community in Georgia.
Jones, A R; Thompson, C J; Davis, M K
2001-10-01
As part of a smoke alarm giveaway and installation program (The Get-Alarmed Campaign), a total of 454 households were surveyed in two counties in Georgia, one metropolitan and one nonmetropolitan. The targeted communities in these counties had a high prevalence of low-income and minority populations and thus were at high risk of house fire-related morbidity and mortality. The objectives of the program were to determine the prevalence of and predictors for installed, functioning smoke alarms, and to install at least one smoke alarm and/or smoke alarm batteries in 100% of participating homes in need. Characteristics associated with smoke alarm ownership included home ownership, having a higher income, and having a central heating source, factors which should be considered in targeting future intervention strategies. At onset, 159/454 households (35.0%) had no smoke alarms installed and 56/275 households with existing smoke alarms (20.4%) had none that were functional. Regardless of ownership status, a free smoke alarm was installed in the household of 93.8% of participants and new batteries were installed in existing smoke alarms for 31.7% of participants. This project illustrates the usefulness of a door-to-door campaign in increasing smoke alarm ownership in both a rural and a suburban community with a high concentration of residents at high risk of house fire-related morbidity and mortality.
78 FR 21567 - Installation of Radiation Alarms for Rooms Housing Neutron Sources
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... [Docket No. PRM-73-15; NRC-2011-0251] Installation of Radiation Alarms for Rooms Housing Neutron Sources... amend its regulations to require the installation of radiation alarms for rooms housing neutron sources... alarms for rooms housing neutron sources. The petitioner stated that the use of alarms can be effective...
46 CFR 78.47-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b) [Reserved] ...
46 CFR 196.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...
46 CFR 97.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...
46 CFR 196.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...
47 CFR 80.318 - Use of alarm signals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...
47 CFR 80.318 - Use of alarm signals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...
46 CFR 108.627 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM...
47 CFR 80.318 - Use of alarm signals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...
47 CFR 80.318 - Use of alarm signals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...
47 CFR 80.318 - Use of alarm signals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...
Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus)
Deng, Huaiqing; Gao, Kai; Zhou, Jiang
2016-01-01
Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002–2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7–10 min) followed by longer variable-frequency mobbing calls lasting 5–12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520–1000 Hz and 690–3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates’ species. The system of vocal alarm behavior described in this critically endangered species is simple and effective. PMID:27686623
Types and Frequency of Infusion Pump Alarms: Protocol for a Retrospective Data Analysis.
Glover, Kevin R; Vitoux, Rachel R; Schuster, Catherine; Curtin, Christopher R
2018-06-14
The variety of alarms from all types of medical devices has increased from 6 to 40 in the last three decades, with today's most critically ill patients experiencing as many as 45 alarms per hour. Alarm fatigue has been identified as a critical safety issue for clinical staff that can lead to potentially dangerous delays or nonresponse to actionable alarms, resulting in serious patient injury and death. To date, most research on medical device alarms has focused on the nonactionable alarms of physiological monitoring devices. While there have been some reports in the literature related to drug library alerts during the infusion pump programing sequence, research related to the types and frequencies of actionable infusion pump alarms remains largely unexplored. The objectives of this study protocol are to establish baseline data related to the types and frequency of infusion pump alarms from the B. Braun Outlook 400ES Safety Infusion System with the accompanying DoseTrac Infusion Management Software. The most recent consecutive 60-day period of backup hospital data received between April 2014 and February 2017 from 32 United States-based hospitals will be selected for analysis. Microsoft SQL Server (2012 - 11.0.5343.0 X64) will be used to manage the data with unique code written to sort data and perform descriptive analyses. A validated data management methodology will be utilized to clean and analyze the data. Data management procedures will include blinding, cleaning, and review of existing infusion data within the DoseTrac Infusion Management Software databases at each hospital. Patient-identifying data will be removed prior to merging into a dedicated and secure data repository. This pooled data will then be analyzed. This exploratory study will analyze the aggregate alarm data for each hospital by care area, drug infused, time of day, and day of week, including: overall infusion pump alarm frequency (number of alarms per active infusion), duration of alarms (average, range, median), and type and frequency of alarms distributed by care area. Infusion pump alarm data collected and analyzed in this study will be used to help establish a baseline of infusion pump alarm types and relative frequencies. Understanding the incidences and characteristics of infusion pump alarms will result in more informed quality improvement recommendations to decrease and/or modify infusion pump alarms, and potentially reduce clinical staff alarm fatigue and improve patient safety. . RR1-10.2196/10446. ©Kevin R Glover, Rachel R Vitoux, Catherine Schuster, Christopher R Curtin. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 14.06.2018.
Li, Jianjun; Wang, Zhengwei; Tan, Ken; Qu, Yufeng; Nieh, James C
2014-10-01
Social pollinators such as honey bees face attacks from predators not only at the nest, but also during foraging. Pollinating honey bees can therefore release alarm pheromones that deter conspecifics from visiting dangerous inflorescences. However, the effect of alarm pheromone and its chemical components upon bee avoidance of dangerous food sources remains unclear. We tested the responses of giant honey bee foragers, Apis dorsata, presented with alarm pheromone at a floral array. Foragers investigated the inflorescence with natural alarm pheromone, but 3.3-fold more foragers preferred to land on the 'safe' inflorescence without alarm pheromone. Using gas chromatography-mass spectrometry analysis, we identified eight chemical components in the alarm pheromone, of which three components (1-octanol, decanal and gamma-octanoic lactone) have not previously been reported in this species. We bioassayed six major compounds and found that a synthetic mixture of these compounds elicited behaviors statistically indistinguishable from responses to natural alarm pheromone. By testing each compound separately, we show that gamma-octanoic lactone, isopentyl acetate and (E)-2-decen-1-yl acetate are active compounds that elicit significant alarm responses. Gamma-octanoic lactone elicited the strongest response to a single compound and has not been previously reported in honey bee alarm pheromone. Isopentyl acetate is widely found in the alarm pheromones of sympatric Asian honey bee species, and thus alarmed A. dorsata foragers may produce information useful for conspecifics and heterospecifics, thereby broadening the effects of alarm information on plant pollination. © 2014. Published by The Company of Biologists Ltd.
Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring.
Nassi, N; Piumelli, R; Lombardi, E; Landini, L; Donzelli, G; de Martino, M
2008-02-01
To compare transthoracic impedance (TTI/ECG) and pulse oximetry alarm traces detected during home monitoring in infants at risk of apnoea, bradycardia and hypoxaemia. A retrospective evaluation of the monitor downloads of 67 infants who had undergone either TTI/ECG or pulse oximetry home monitoring using a device which can detect both parameters. The patients were categorised as: apparent life-threatening events (n = 39), preterm infants (n = 21) and miscellaneous (n = 7). TTI/ECG and pulse oximetry alarm traces were scored as either true or false alarms. Classification criteria were based on visual analysis of the impedance and plethysmographic waveforms captured by the memory monitor every time alarm thresholds were violated. 5242 alarms occurred over 3452 days of monitoring: 4562 (87%) were false and 680 (13%) true. The mean duration of monitoring was 51 days (range 5-220 days). There were 2982 TTI/ECG false alarms (65% of the total) and 1580 pulse oximetry false alarms (35%) (p = 0.0042). Of the 680 true alarms, 507 (74%) were desaturations not attributable to central apnoea and 173 (26%) were true TTI/ECG alarms (p = 0.0013). Comparison of pulse oximetry and TTI/ECG alarm traces shows that true events were mostly attributable to desaturations, while false alarms were mainly provoked by TTI/ECG. The total number of false alarms is lower than reported in other studies using TTI/ECG only, thus indicating that monitoring using both pulse oximetry and TTI/ECG is suitable for home use. When the combination of both techniques is not feasible or not required, we recommend the use of motion resistant pulse oximetry alone.
Locomotor effects of a low-frequency fire alarm on C57BL/6 male mice: a preliminary study.
Povroznik, Jessica M; Faith, Robert E; Kessler, Matthew J; Ali, Frank N; Kosik, James; Prince, Stephen; Engler-Chiurazzi, Elizabeth B
2017-12-01
Maintaining appropriate acoustic conditions for animal welfare and data collection are crucial in biomedical research facilities. Negative impacts of disruptive sound are known and can include auditory damage, immune function changes, and behavioral alterations. One type of disruptive sound occurring in research facilities is that of fire alarms. To ameliorate this problem, many facilities have incorporated the use of low-frequency fire alarms that emit tones outside the rodent audible range. The impact of these devices has been assumed to be negligible. However, this has yet to be evaluated with controlled behavioral experiments. Thus, our objective was to investigate the impact of low-frequency fire alarm exposure on locomotor behavior in the open field, a test sensitive to acoustic stimuli disruption. Male mice were randomized to three alarm exposure groups (No-Alarm; Alarm-During; and Alarm-After) and placed in individual photobeam-activated locomotor chambers. The Alarm-During group displayed significantly reduced horizontal locomotion, with a trend towards reduced vertical locomotion. These data suggest that a low-frequency brief alarm tone can temporarily disrupt movement, a valuable insight should an alarm be deployed. Further, findings support close collaboration between researchers and institutional facility staff to ensure appropriate acoustic conditions are maintained, whenever possible, for research animals.
Isolation of a pyrazine alarm pheromone component from the fire ant, Solenopsis invicta.
Vander Meer, Robert K; Preston, Catherine A; Choi, Man-Yeon
2010-02-01
Alarm pheromones in social insects are an essential part of a complex of pheromone interactions that contribute to the maintenance of colony integrity and sociality. The alarm pheromones of ants were among the first examples of animal pheromones identified, primarily because of the large amount of chemical produced and the distinctive responses of ants to the pheromone. However, the alarm pheromone of the fire ant, Solenopsis invicta, eluded identification for over four decades. We identified 2-ethyl-3,6-dimethylpyrazine as an alarm pheromone component of S. invicta. Worker fire ants detect the pyrazine alarm pheromone at 30 pg/ml, which is comparable to alarm pheromone sensitivities reported for other ant species. The source of this alarm pheromone are the mandibular glands, which, in fire ants, are not well developed and contain only about 300 pg of the compound, much less than the microgram quantities of alarm pheromones reported for several other ant species. Female and male sexuals and workers produce the pyrazine, which suggests that it may be involved in fire ant mating flight initiation, as well as the typical worker alarm response. This is the first report of 2-ethyl-3,6-dimethylpyrazine from a Solenopsis species and the first example of this alkaloid functioning as an alarm pheromone.
Hättenschwiler, Nicole; Sterchi, Yanik; Mendes, Marcia; Schwaninger, Adrian
2018-10-01
Bomb attacks on civil aviation make detecting improvised explosive devices and explosive material in passenger baggage a major concern. In the last few years, explosive detection systems for cabin baggage screening (EDSCB) have become available. Although used by a number of airports, most countries have not yet implemented these systems on a wide scale. We investigated the benefits of EDSCB with two different levels of automation currently being discussed by regulators and airport operators: automation as a diagnostic aid with an on-screen alarm resolution by the airport security officer (screener) or EDSCB with an automated decision by the machine. The two experiments reported here tested and compared both scenarios and a condition without automation as baseline. Participants were screeners at two international airports who differed in both years of work experience and familiarity with automation aids. Results showed that experienced screeners were good at detecting improvised explosive devices even without EDSCB. EDSCB increased only their detection of bare explosives. In contrast, screeners with less experience (tenure < 1 year) benefitted substantially from EDSCB in detecting both improvised explosive devices and bare explosives. A comparison of all three conditions showed that automated decision provided better human-machine detection performance than on-screen alarm resolution and no automation. This came at the cost of slightly higher false alarm rates on the human-machine system level, which would still be acceptable from an operational point of view. Results indicate that a wide-scale implementation of EDSCB would increase the detection of explosives in passenger bags and automated decision instead of automation as diagnostic aid with on screen alarm resolution should be considered. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
46 CFR 78.47-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM...
Luhring, Thomas M; Meckley, Trevor D.; Johnson, Nicholas S.; Siefkes, Michael J.; Hume, John B.; Wagner, C. Michael
2016-01-01
Animals make trade-offs between predation risk and pursuit of opportunities such as foraging and reproduction. Trade-offs between antipredator behaviours and foraging are well suited to manipulation in laboratory and field settings and have generated a vast compendium of knowledge. However, much less is known about how animals manage trade-offs between predation risk and pursuit of reproductive opportunities in the absence of the confounding effects of foraging. In the present study, we investigated how the nonfeeding migratory life stage of sea lamprey, Petromyzon marinus, responds to odour from dead conspecifics (a cue that induces avoidance behaviours in laboratory and field studies). We released groups of PIT-tagged sea lamprey 65 m from the shore of Lake Michigan or 287 m upstream in Carp Lake River and used antennas to detect their movements in the river. As the breeding season progressed, sea lamprey initiated upstream movement earlier and were more likely to enter the river. Sea lamprey that began the night in Lake Michigan entered Carp Lake River at higher rates and accelerated upstream when exposed to high concentrations of alarm cue, consistent with animals attempting to minimize time spent in risky areas. Sea lampreys that began the night in the river delayed upstream movement when exposed to alarm cue, consistent with animals sheltering and gathering information about a source of risk. We attribute this context-specific reaction to alarm cue to differences in perceived vulnerability to predation in sheltered positions in the river versus exposed positions in the lake. Once in the river, the vast majority of sea lamprey moved upstream independent of alarm cue or Julian date. Although life-history-induced time and energy budgets place rigid constraints on the direction of migration, sea lamprey attend to predation risk by modifying movement timing and speed.
Bonneville Power Administration Communication Alarm Processor expert system:
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goeltz, R.; Purucker, S.; Tonn, B.
This report describes the Communications Alarm Processor (CAP), a prototype expert system developed for the Bonneville Power Administration by Oak Ridge National Laboratory. The system is designed to receive and diagnose alarms from Bonneville's Microwave Communications System (MCS). The prototype encompasses one of seven branches of the communications network and a subset of alarm systems and alarm types from each system. The expert system employs a backward chaining approach to diagnosing alarms. Alarms are fed into the expert system directly from the communication system via RS232 ports and sophisticated alarm filtering and mailbox software. Alarm diagnoses are presented to operatorsmore » for their review and concurrence before the diagnoses are archived. Statistical software is incorporated to allow analysis of archived data for report generation and maintenance studies. The delivered system resides on a Digital Equipment Corporation VAX 3200 workstation and utilizes Nexpert Object and SAS for the expert system and statistical analysis, respectively. 11 refs., 23 figs., 7 tabs.« less
Ballesteros, Michael F; Kresnow, Marcie-Jo
2007-01-01
This study was conducted to estimate (1) the proportion of U.S. homes with installed smoke alarms and fire escape plans, and (2) the frequency of testing home smoke alarms and of practicing the fire escape plans. The authors analyzed data on smoke alarms and fire escape plans from a national cross-sectional random-digit dialed telephone survey of 9,684 households. Ninety-five percent of surveyed households reported at least one installed smoke alarm and 52% had a fire escape plan. The prevalence of alarms varied by educational level, income, and the presence of a child in the home. Only 15% tested their alarms once a month and only 16% of homes with an escape plan reported practicing it every six months. While smoke alarm prevalence in U.S. homes is high, only half of homes have a fire escape plan. Additional emphasis is needed on testing of installed smoke alarms and on preparedness for fire escape plans.
10th Annual School Construction Report, 2005
ERIC Educational Resources Information Center
Abramson, Paul
2005-01-01
School construction in the United States dipped below $20 billion in 2003, the first time that had happened in the 21st Century, setting off alarm bells that the school construction boom might be fading. That concern appears to be unfounded. In 2004, school districts in the United States once again completed more than $20 billion worth of…
Investing in High Quality Preschool: Lessons from an Urban Setting
ERIC Educational Resources Information Center
Dorman, Rebekah L.; Anthony, Elizabeth; Osborne-Fears, Billie; Fischer, Robert L.
2017-01-01
Large numbers of children of low income families in the United States arrive at kindergarten already far behind their more affluent peers on measures of school readiness. In the absence of any federal preschool policy and amidst alarm about this growing divide, universal prekindergarten (UPK) programs have been launched around the United States,…
Using Modeling and Rehearsal to Teach Fire Safety to Children with Autism
ERIC Educational Resources Information Center
Garcia, David; Dukes, Charles; Brady, Michael P.; Scott, Jack; Wilson, Cynthia L.
2016-01-01
We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to…
Implementation of a light-route TDMA communications satellite system for advanced business networks
NASA Astrophysics Data System (ADS)
Hanson, B.; Smalley, A.; Zuliani, M.
The application of Light Route TDMA systems to various business communication requirements is discussed. It is noted that full development of this technology for use in advanced business networks will be guided by considerations of flexibility, reliability, security, and cost. The implementation of the TDMA system for demonstrating these advantages to a wide range of public and private organizations is described in detail. Among the advantages offered by this system are point-to-point and point-to-multipoint (broadcast) capability; the ability to vary the mix and quantity of services between destinations in a fully connected mesh network on an almost instantaneous basis through software control; and enhanced reliability with centralized monitor, alarm and control functions by virtue of an overhead channel.
Frattaroli, Shannon; McDonald, Eileen M; Tran, Nhan T; Trump, Alison R; OʼBrocki, Raymond C; Gielen, Andrea C
2012-01-01
Smoke alarm canvassing is recognized as an empirically based, effective intervention for increasing access to and the presence of smoke alarms in homes. We sought to inform the implementation of an intervention designed to enhance an existing fire department smoke alarm canvassing program through an empirically grounded, participatory process. We conducted a series of focus groups with fire union leaders and firefighters involved with the canvassing program in 1 US city, shared the results with the participants, and presented the resulting recommendations to fire department leadership. This research occurred in Baltimore, Maryland. Focus group participants included firefighters who participate in the Fire Department's smoke alarm canvassing program and representatives from the local firefighters' union. The focus groups sought to capture firefighters' experiences with and opinions about the canvassing program and how to improve it as well as challenges to canvassing work. We conducted 10 focus groups with 65 participants. Firefighters' perspectives on the canvassing program and their recommendations for improving it were expressed through 3 categories of themes concerning program management, canvassing challenges, and attitudes about the program and the community. We also discuss the process of presenting these findings and recommendations to the participants and the fire department leadership, and describe how implementation of some of the recommendations has progressed. Both the process and outcomes of this formative work inform how to develop and implement community-based public health interventions in real-world settings through academic-community partnerships. The findings also have implications for how canvassing programs are being implemented.
The Roots and Implications of East Asian Regionalism
2004-09-01
Despite earlier imperialist ventures, most Americans looked askance at European colonial empires and subscribed to the idea of national self ... Malaysian Prime Minister Mahathir–alarmed by the establishment of the North American Free Trade Area (NAFTA) which seemed to portend a new era The Roots...wisdom.) Still other pan-Asianists pointed to basic cultural commonalities among Asians such as their closeness to nature and esteem of group values
Smoke alarms in the home: what every physician should know
Sultan, Mohammed A.; Feldman, William M.
1985-01-01
Primary care physicians interested in health education and accident prevention should be knowledgeable about smoke alarms (smoke detectors with built-in alarms). Either ionization or photoelectric smoke alarms can help save lives if they are properly installed and maintained. The number, site and maintenance of smoke alarms in the home and the steps a person should take in the event of a fire are discussed. Considering the rates of death, disability and disfigurement associated with residential fires, early warning devices such as smoke alarms make sense. PMID:4063931
Cristaldo, Paulo F.; Jandák, Vojtĕch; Kutalová, Kateřina; Rodrigues, Vinícius B.; Brothánek, Marek; Jiříček, Ondřej; DeSouza, Og; Šobotník, Jan
2015-01-01
ABSTRACT Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae), confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S)-α-pinene and myrcene, along with a minor component, (E)-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards) resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant) increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through vibratory signals, and higher levels causing general alarm or retreat being communicated through the alarm pheromone. PMID:26538635
Priority coding for control room alarms
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
Indicating the priority of a spatially fixed, activated alarm tile on an alarm tile array by a shape coding at the tile, and preferably using the same shape coding wherever the same alarm condition is indicated elsewhere in the control room. The status of an alarm tile can change automatically or by operator acknowledgement, but tones and/or flashing cues continue to provide status information to the operator.
An experimental investigation of the effects of alarm processing and display on operator performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Hara, J.; Brown, W.; Hallbert, B.
1998-03-01
This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluatemore » the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance, operator task performance, situation awareness, and workload were obtained. In addition, operator opinions and evaluations of the alarm processing and display conditions were collected. No deficient performance was observed in any of the experimental conditions, providing confirmatory support for many design review guidelines. The operators identified numerous strengths and weaknesses associated with individual alarm design characteristics.« less
GNSS Signal Authentication Via Power and Distortion Monitoring
NASA Astrophysics Data System (ADS)
Wesson, Kyle D.; Gross, Jason N.; Humphreys, Todd E.; Evans, Brian L.
2018-04-01
We propose a simple low-cost technique that enables civil Global Positioning System (GPS) receivers and other civil global navigation satellite system (GNSS) receivers to reliably detect carry-off spoofing and jamming. The technique, which we call the Power-Distortion detector, classifies received signals as interference-free, multipath-afflicted, spoofed, or jammed according to observations of received power and correlation function distortion. It does not depend on external hardware or a network connection and can be readily implemented on many receivers via a firmware update. Crucially, the detector can with high probability distinguish low-power spoofing from ordinary multipath. In testing against over 25 high-quality empirical data sets yielding over 900,000 separate detection tests, the detector correctly alarms on all malicious spoofing or jamming attacks while maintaining a <0.6% single-channel false alarm rate.
Algorithm of reducing the false positives in IDS based on correlation Analysis
NASA Astrophysics Data System (ADS)
Liu, Jianyi; Li, Sida; Zhang, Ru
2018-03-01
This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.
... allow CO to come indoors. In addition, install battery-operated CO alarms or plug-in CO alarms with battery back-up in your home. Every home should ... Test your CO alarms frequently and replace dead batteries. A CO alarm can provide added protection, but ...
Rowland, Diane; Afolabi, Elizabeth; Roberts, Ian
2002-09-01
Despite an increased risk of fire in disadvantaged households, smoke alarm ownership is considerably lower than in the general population. The government currently recommends that local authorities install battery-operated smoke alarms in all public sector properties regardless of tenure. However, the extent to which local authorities comply is currently not known. We conducted a survey of local authorities to establish the extent of their smoke alarm provision to public sector households. A telephone survey of all 405 local authorities within England and Wales was carried out. We obtained responses from 390 (97 per cent) local authorities, 266 of which had responsibility for housing. Over half of all public-sector households are offered smoke alarms by the local authorities. The majority of local authorities offer ionization and/or optical sensor alarm types (78 per cent), with many local authorities providing battery-operated alarms alone (17 per cent) or in combination with hardwired alarms (31 per cent). Many local authorities offer smoke alarm provision to their public-sector households. Whether this represents an effective and cost-effective use of resources requires further investigation.
Residential smoke alarms and fire escape plans.
Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F
1998-01-01
To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household.
Using behavioral science to improve fire escape behaviors in response to a smoke alarm.
Thompson, N J; Waterman, M B; Sleet, D A
2004-01-01
Although the likelihood of fire-related death in homes with smoke alarms is about one-half that in homes without alarms, alarm effectiveness is limited by behavior. Only 16% of residents of homes with alarms have developed and practiced plans for escape when the alarm sounds. We reviewed literature to identify behavioral constructs that influence smoke alarm use. We then convened experts in the behavioral aspects of smoke alarms who reviewed the constructs and determined that the appropriate areas for behavioral focus were formulating, practicing, and implementing escape plans should an alarm sound. They subsequently identified important behaviors to be addressed by burn-prevention programs and incorporated the constructs into a behavioral model for use in such programs. Finally, we organized the available literature to support this model and make programmatic recommendations. Many gaps remain in behavioral research to improve fire escape planning and practice. Future research must select the target behavior, apply behavioral theories, and distinguish between initiation and maintenance of behaviors associated with planning, practicing, and implementing home fire escape plans.
Residential smoke alarms and fire escape plans.
Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F
1998-01-01
OBJECTIVE: To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. METHODS: The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. RESULTS: Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. CONCLUSIONS: Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household. PMID:9769771
Effect of station-specific alerting and ramp-up tones on firefighters' alarm time heart rates.
MacNeal, James J; Cone, David C; Wistrom, Christopher L
2016-11-01
A number of long-term health effects are suffered by emergency responders, some influenced by psychological stress and fatigue. This study explored if stress and fatigue can be reduced by changing the method by which firefighters are alerted to emergency responses. Over several months, the method by which responders at a fire department were alerted was altered. Firefighter heart rates were measured first with standard alerting as a control (phase 1: all stations alerted simultaneously, with high-volume tones). The department then implemented station-specific (phase 2) and gradual volume ramp-up (phase 3) tone alerting, and heart rate increases were compared. The Fatigue Severity Score was used to examine firefighter fatigue, and the department administered a follow-up survey on personnel preferences. Individual heart rate increases (Δbpm) ranged from 2-48 bpm. Median increases were 7 bpm (IQR 4-11 bpm) during phase 1 (72.2% of alarms Δbpm<10), 7 bpm (IQR 5-12 bpm) during phase 2 (60.7% of alarms Δbpm<10), and 5 bpm (IQR 3-8 bpm) during phase 3 (82.7% of alarms Δbpm<10). The difference in medians was lower for phases 1 and 2 than for phase 3 (p = 0.0069), and more alarms in phase 3 resulted in increases of <10 bpm than in phase 2 (p = 0.0089). The Fatigue Severity Scale showed little variability: median scores 7 in phase 1, 8 in phase 2, and 7 in phase 3. Firefighters reported a strong preference for the "ramp-up" tones, and were roughly evenly divided between preferring alerting all stations simultaneously 24/7 (40% rating this 4 or 5 on a five-point Likert scale), station-specific alerting 24/7 (47.5%), or all stations during the day but station-specific at night (40%). Ramp-up tones were perceived as the best method to reduce stress during the day and overnight. Small but significant decreases in the amount of tachycardic response to station alerting are associated with simple alterations in alerting methods. Station-specific and ramp-up tones improve perceived working conditions for emergency responders.
Joshi, Rohan; Straaten, Henrica van; Mortel, Heidi van de; Long, Xi; Andriessen, Peter; Pul, Carola van
2018-06-30
To determine differences in alarm pressure between two otherwise comparable neonatal intensive care units (NICUs) differing in architectural layout-one of a single-family room (SFR) design and the other of an open bay area (OBA) design. Retrospective audit of more than 2000 patient days from each NICU cataloguing the differences in the number and duration of alarms for critical and alerting alarms, as well as the interaction of clinicians with the patient monitor. Two level 3 NICUs. A total of more than 150 000 critical and 1.2 million alerting alarms were acquired from the two NICUs. The number of audible alarms and the associated noise pollution varied considerably with the OBA NICU generating 44% more alarms per infant per day even though the SFR NICU generated 2.5 as many critical desaturation alarms per infant per day. Differences in the architectural layout of NICUs and the consequent differences in delays, thresholds and distribution systems for alarms are associated with differences in alarm pressure. © Author(s) (or their employer(s)) 2018. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.
Receivers matter: the meaning of alarm calls and competition for nest sites in a bird community.
Parejo, Deseada; Avilés, Jesús M; Expósito-Granados, Mónica
2018-04-11
Animal communities may constitute information networks where individuals gain information on predation risk by eavesdropping on alarm calls of other species. However, communities include species in different trophic levels, and it is not yet known how the trophic level of the receiver influences the informative value of a call. Furthermore, no empirical study has yet tested how increased competition may influence the value of alarm calls for distinct receivers. Here, we identify the importance of alarm calls emitted by a small owl, the little owl (Athene noctua), on the structure of a cavity-nesting bird community including mesopredators and primary prey under variable levels of competition for nest holes. Competitors sharing top predators with the callers and prey of the callers interpreted alarm and non-alarm calls differently. Competitors chose preferentially alarm and non-alarm patches over control patches to breed, while prey selected alarm patches. In contrast, competition for nest sites affected habitat selection of prey species more than that of competitors of the callers. This study provides support for a changing value of alarm calls and competition for nest sites for distinct receivers related to niche overlapping among callers and eavesdroppers, therefore, calling attention to possible cascading effects by the use of information in natural communities.
Design of multi-function sensor detection system in coal mine based on ARM
NASA Astrophysics Data System (ADS)
Ge, Yan-Xiang; Zhang, Quan-Zhu; Deng, Yong-Hong
2017-06-01
The traditional coal mine sensor in the specific measurement points, the number and type of channel will be greater than or less than the number of monitoring points, resulting in a waste of resources or cannot meet the application requirements, in order to enable the sensor to adapt to the needs of different occasions and reduce the cost, a kind of multi-functional intelligent sensor multiple sensors and ARM11 the S3C6410 processor is used to design and realize the dust, gas, temperature and humidity sensor functions together, and has storage, display, voice, pictures, data query, alarm and other new functions.
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4360 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm...
Meno, Whitney; Coss, Richard G; Perry, Susan
2013-03-01
Young animals are known to direct alarm calls at a wider range of animals than adults. If social cues are safer and/or more reliable to use than asocial cues for learning about predators, then it is expected that the development of this behavior will be affected by the social environment. Our study examined the influence of the social environment on antipredator behavior in infant, juvenile, and adult wild white-faced capuchin monkeys (Cebus capucinus) at Lomas Barbudal Biological Reserve in Costa Rica during presentations of different species of model snakes and novel models. We examined (a) the alarm calling behavior of the focal animal when alone versus in the vicinity of conspecific alarm callers and (b) the latency of conspecifics to alarm call once the focal animal alarm called. Focal animals alarm called more when alone than after hearing a conspecific alarm call. No reliable differences were found in the latencies of conspecifics to alarm call based on age or model type. Conspecifics were more likely to alarm call when focal individuals alarm called at snake models than when they alarm called at novel models. Results indicate (a) that alarm calling may serve to attract others to the predator's location and (b) that learning about specific predators may begin with a generalized response to a wide variety of species, including some nonthreatening ones, that is winnowed down via Pavlovian conditioned inhibition into a response directed toward specific dangerous species. This study reveals that conspecifics play a role in the development of antipredator behavior in white-faced capuchins. © 2012 Wiley Periodicals, Inc.
Smoke alarm installation and function in inner London council housing.
DiGuiseppi, C; Roberts, I; Speirs, N
1999-11-01
To determine the prevalence of and predictors for installed, functioning smoke alarms in council (public) housing in a low income, multi-ethnic urban area. Cross sectional study. 40 materially deprived electoral wards in two inner London boroughs. Occupants of 315 addresses randomly selected from council housing lists, with 75% response rate. Installation and function of smoke alarms based on inspection and testing. 39% (95% confidence interval (CI) 33% to 46%) of council tenants owned a smoke alarm, 31% (95% CI 25% to 38%) had an installed alarm (of which 54% were correctly installed), and 16% (95% CI 12% to 22%) had at least one installed, functioning alarm. Alarms most commonly failed because they lacked batteries (72%). In multivariate modelling, having an installed, functioning alarm was most strongly associated with living in a house versus a flat (apartment) (odds ratio (OR) 3.2, 95% CI 1.1 to 10.0), having two resident adults versus one (OR 2.8, 95% CI 1.2 to 6.5), and recognising stills from a Home Office television smoke alarm campaign (OR 2.4, 95% CI 1.1 to 5.5). Fires are a leading cause of child injury and death, particularly among those younger than 5 years of age and those in social classes IV and V. Smoke alarms are associated with a significantly reduced risk of death in residential fires, and are more protective in households with young children. Few council properties in a multi-ethnic, materially deprived urban area had any installed, functioning smoke alarms, despite a high risk of residential fires and fire related injuries in such areas. Effective methods to increase the prevalence of installed and functioning alarms must be identified.
Smoke alarm installation and function in inner London council housing
DiGuiseppi, C.; Roberts, I.; Speirs, N.
1999-01-01
AIM—To determine the prevalence of and predictors for installed, functioning smoke alarms in council (public) housing in a low income, multi-ethnic urban area. DESIGN—Cross sectional study. SETTING—40 materially deprived electoral wards in two inner London boroughs. PARTICIPANTS—Occupants of 315 addresses randomly selected from council housing lists, with 75% response rate. MAIN OUTCOME MEASURES—Installation and function of smoke alarms based on inspection and testing. RESULTS—39% (95% confidence interval (CI) 33% to 46%) of council tenants owned a smoke alarm, 31% (95% CI 25% to 38%) had an installed alarm (of which 54% were correctly installed), and 16% (95% CI 12% to 22%) had at least one installed, functioning alarm. Alarms most commonly failed because they lacked batteries (72%). In multivariate modelling, having an installed, functioning alarm was most strongly associated with living in a house versus a flat (apartment) (odds ratio (OR) 3.2, 95% CI 1.1 to 10.0), having two resident adults versus one (OR 2.8, 95% CI 1.2 to 6.5), and recognising stills from a Home Office television smoke alarm campaign (OR 2.4, 95% CI 1.1 to 5.5). CONCLUSIONS—Fires are a leading cause of child injury and death, particularly among those younger than 5 years of age and those in social classes IV and V. Smoke alarms are associated with a significantly reduced risk of death in residential fires, and are more protective in households with young children. Few council properties in a multi-ethnic, materially deprived urban area had any installed, functioning smoke alarms, despite a high risk of residential fires and fire related injuries in such areas. Effective methods to increase the prevalence of installed and functioning alarms must be identified. PMID:10519711
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
Inta, R; Evans, T A; Lai, J C S
2009-02-01
Termite soldiers produce a vibratory alarm signal to warn conspecific workers. This study recorded and characterized the alarm signals of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae) and then investigated the effect of playing these recorded alarm signals on C. acinaciformis feeding activity. Foraging groups of termites were offered paired wooden blocks: either one block, continuously stimulated with a vibratory alarm signal, paired with a nonstimulated block (the alarm treatment), continuously stimulated with a pink noise signal, paired with a nonstimulated block (control for nonspecific vibrations) or two nonstimulated blocks (control for environmental effects), for 4 wk. The amount of wood eaten in the blocks stimulated by the alarm signals was significantly less than the paired nonstimulated blocks, while there seemed to be no preference in the case of the pink noise playback or control for direction. Importantly, the termites seemed not to have adapted to the recorded alarm signal over the 4-wk duration of the experiment, unlike previous studies using nonbiologically derived signals.
One Common Future, Two Education Systems: The Case of Syrian Children of Istanbul
ERIC Educational Resources Information Center
Ozer, Y. Yesim; Komsuoglu, Aysegul; Atesok, Z. Ozde
2017-01-01
The unexpected and vast Syrian refugee crisis with an ever-growing number of young Syrians appears to be one of the greatest challenges for the Turkish education system. While low enrollment rates are alarming, the dual system that emerged in the urban settings creates a main challenge to a comprehensive and supportive education system and…
New Ratings of Humanities Journals Do More than Rank--They Rankle
ERIC Educational Resources Information Center
Howard, Jennifer
2008-01-01
This paper reports that a large-scale, multinational attempt in Europe to rank humanities journals has set off a revolt. In a protest letter, some journal editors have called it "a dangerous and misguided exercise." The project has also started a drumbeat of alarm in this country, as U.S.-based scholars begin to grasp the implications…
Early Intervention in a Child Care Setting Using Play and Family Therapy
ERIC Educational Resources Information Center
Matte, Rebecca L.; Messmore, Carol
2013-01-01
At an alarming rate, preschoolers are being expelled from child care centers because of disruptive behavior, and elementary schools are dealing with social-emotional behaviors that affect the entire classroom. The authors share the story of a child who would have been one of those expelled from child care and at risk in the elementary school…
Alarms Sounded as Federal-Aid Ax Heaves into View
ERIC Educational Resources Information Center
Klein, Alyson
2012-01-01
Education advocates and the Obama administration are anxiously eyeing a series of across-the-board cuts set to hit a broad swath of federal domestic and military spending programs early next year, unless a sharply divided Congress can agree on a long-term plan to put the nation's fiscal house in order. Most education lobbyists expect such a deal…
ERIC Educational Resources Information Center
Finkelhor, David
2014-01-01
This commentary on Livingstone and Smith (2014) suggests that more attention should be paid to a set of hypotheses about technology that contrasts with those that have animated much of the current research interest: (a) That the digital environment is no more perilous and perhaps less perilous than other offline environments youth inhabit; (b)…
Space-Time Earthquake Prediction: The Error Diagrams
NASA Astrophysics Data System (ADS)
Molchan, G.
2010-08-01
The quality of earthquake prediction is usually characterized by a two-dimensional diagram n versus τ, where n is the rate of failures-to-predict and τ is a characteristic of space-time alarm. Unlike the time prediction case, the quantity τ is not defined uniquely. We start from the case in which τ is a vector with components related to the local alarm times and find a simple structure of the space-time diagram in terms of local time diagrams. This key result is used to analyze the usual 2-d error sets { n, τ w } in which τ w is a weighted mean of the τ components and w is the weight vector. We suggest a simple algorithm to find the ( n, τ w ) representation of all random guess strategies, the set D, and prove that there exists the unique case of w when D degenerates to the diagonal n + τ w = 1. We find also a confidence zone of D on the ( n, τ w ) plane when the local target rates are known roughly. These facts are important for correct interpretation of ( n, τ w ) diagrams when we discuss the prediction capability of the data or prediction methods.
Human detection and motion analysis at security points
NASA Astrophysics Data System (ADS)
Ozer, I. Burak; Lv, Tiehan; Wolf, Wayne H.
2003-08-01
This paper presents a real-time video surveillance system for the recognition of specific human activities. Specifically, the proposed automatic motion analysis is used as an on-line alarm system to detect abnormal situations in a campus environment. A smart multi-camera system developed at Princeton University is extended for use in smart environments in which the camera detects the presence of multiple persons as well as their gestures and their interaction in real-time.
Change-based threat detection in urban environments with a forward-looking camera
NASA Astrophysics Data System (ADS)
Morton, Kenneth, Jr.; Ratto, Christopher; Malof, Jordan; Gunter, Michael; Collins, Leslie; Torrione, Peter
2012-06-01
Roadside explosive threats continue to pose a significant risk to soldiers and civilians in conflict areas around the world. These objects are easy to manufacture and procure, but due to their ad hoc nature, they are difficult to reliably detect using standard sensing technologies. Although large roadside explosive hazards may be difficult to conceal in rural environments, urban settings provide a much more complicated background where seemingly innocuous objects (e.g., piles of trash, roadside debris) may be used to obscure threats. Since direct detection of all innocuous objects would flag too many objects to be of use, techniques must be employed to reduce the number of alarms generated and highlight only a limited subset of possibly threatening regions for the user. In this work, change detection techniques are used to reduce false alarm rates and increase detection capabilities for possible threat identification in urban environments. The proposed model leverages data from multiple video streams collected over the same regions by first applying video aligning and then using various distance metrics to detect changes based on image keypoints in the video streams. Data collected at an urban warfare simulation range at an Eastern US test site was used to evaluate the proposed approach, and significant reductions in false alarm rates compared to simpler techniques are illustrated.
An Intelligent Surveillance Platform for Large Metropolitan Areas with Dense Sensor Deployment
Fernández, Jorge; Calavia, Lorena; Baladrón, Carlos; Aguiar, Javier M.; Carro, Belén; Sánchez-Esguevillas, Antonio; Alonso-López, Jesus A.; Smilansky, Zeev
2013-01-01
This paper presents an intelligent surveillance platform based on the usage of large numbers of inexpensive sensors designed and developed inside the European Eureka Celtic project HuSIMS. With the aim of maximizing the number of deployable units while keeping monetary and resource/bandwidth costs at a minimum, the surveillance platform is based on the usage of inexpensive visual sensors which apply efficient motion detection and tracking algorithms to transform the video signal in a set of motion parameters. In order to automate the analysis of the myriad of data streams generated by the visual sensors, the platform's control center includes an alarm detection engine which comprises three components applying three different Artificial Intelligence strategies in parallel. These strategies are generic, domain-independent approaches which are able to operate in several domains (traffic surveillance, vandalism prevention, perimeter security, etc.). The architecture is completed with a versatile communication network which facilitates data collection from the visual sensors and alarm and video stream distribution towards the emergency teams. The resulting surveillance system is extremely suitable for its deployment in metropolitan areas, smart cities, and large facilities, mainly because cheap visual sensors and autonomous alarm detection facilitate dense sensor network deployments for wide and detailed coverage. PMID:23748169
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
1983-06-30
activating a separate transmitter, audible alarm, or contact closure. This sensor is compatible with any device that utilizes an input pulse or...transmitter, audible alarm, or contact closure. This sensor is compatible *i with any device that utilizes an output to produce an alarm. 110-4769-002. This...used to generate an alarm by activating a separate transmitter, audible alarm, or contact closure. This sensor is compatible with any device that
Spilki, Fernando Rosado; da Luz, Roger Bordin; Fabres, Rafael Bandeira; Soliman, Mayra Cristina; Kluge, Mariana; Fleck, Juliane Deise; Rodrigues, Manoela Tressoldi; Comerlato, Juliana; Cenci, Alexander; Cerva, Cristine; Dasso, Maurício Gautério; Roehe, Paulo Michel
2013-01-01
Viral gastroenteritis and other waterborne diseases are a major concern for health in Brazil. A number of studies were conducted about the presence of viruses on water samples from Brazilian areas. However, the knowledge about the occurrence of viral contamination of drinking water sources in rural settings of the country is insufficient. On the present work, 15 samples from 5 dairy farms located at the municipality of Tenente Portela were collected and analysed for the presence of human adenoviruses (HAdV), as well as human enteroviruses (EV) and rotaviruses (RV). HAdV was present on 66.66% of the water samples, and have been found in all samples from artesian wells and springs, which are used as sources of drinking water for the individuals inhabiting those farms. EV and RV found only in one sample each. The detection rates of HAdV on the water from these dairy farms are alarming and point towards a situation of elevated environmental contamination by fecal microorganisms of human origin and poor basic sanitation conditions. PMID:24516464
Combining multiple earthquake models in real time for earthquake early warning
Minson, Sarah E.; Wu, Stephen; Beck, James L; Heaton, Thomas H.
2017-01-01
The ultimate goal of earthquake early warning (EEW) is to provide local shaking information to users before the strong shaking from an earthquake reaches their location. This is accomplished by operating one or more real‐time analyses that attempt to predict shaking intensity, often by estimating the earthquake’s location and magnitude and then predicting the ground motion from that point source. Other EEW algorithms use finite rupture models or may directly estimate ground motion without first solving for an earthquake source. EEW performance could be improved if the information from these diverse and independent prediction models could be combined into one unified, ground‐motion prediction. In this article, we set the forecast shaking at each location as the common ground to combine all these predictions and introduce a Bayesian approach to creating better ground‐motion predictions. We also describe how this methodology could be used to build a new generation of EEW systems that provide optimal decisions customized for each user based on the user’s individual false‐alarm tolerance and the time necessary for that user to react.
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
24 CFR 3280.208 - Smoke alarm requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. (a) Labeling. Each smoke alarm required under paragraph (b) of this section must conform with the...
24 CFR 3280.208 - Smoke alarm requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. (a) Labeling. Each smoke alarm required under paragraph (b) of this section must conform with the...
24 CFR 3280.208 - Smoke alarm requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. (a) Labeling. Each smoke alarm required under paragraph (b) of this section must conform with the...
24 CFR 3280.208 - Smoke alarm requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. Link to an amendment published at 78 FR 73982, Dec. 9, 2013. (a) Labeling. Each smoke alarm...
21 CFR 870.1100 - Blood pressure alarm.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...
21 CFR 870.1100 - Blood pressure alarm.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...
21 CFR 870.1100 - Blood pressure alarm.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...
21 CFR 870.1100 - Blood pressure alarm.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...
46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...
46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...
46 CFR 108.623 - General alarm bell switch.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing. ...
46 CFR 108.623 - General alarm bell switch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing. ...
46 CFR 108.623 - General alarm bell switch.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing. ...
46 CFR 108.623 - General alarm bell switch.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing. ...
46 CFR 108.623 - General alarm bell switch.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing. ...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
40 CFR 265.34 - Access to communications or alarm system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Access to communications or alarm..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm... involved in the operation must have immediate access to an internal alarm or emergency communication device...
40 CFR 264.34 - Access to communications or alarm system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Access to communications or alarm... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... operation must have immediate access to an internal alarm or emergency communication device, either directly...
NASA Astrophysics Data System (ADS)
Dong, Xiabin; Huang, Xinsheng; Zheng, Yongbin; Bai, Shengjian; Xu, Wanying
2014-07-01
Infrared moving target detection is an important part of infrared technology. We introduce a novel infrared small moving target detection method based on tracking interest points under complicated background. Firstly, Difference of Gaussians (DOG) filters are used to detect a group of interest points (including the moving targets). Secondly, a sort of small targets tracking method inspired by Human Visual System (HVS) is used to track these interest points for several frames, and then the correlations between interest points in the first frame and the last frame are obtained. Last, a new clustering method named as R-means is proposed to divide these interest points into two groups according to the correlations, one is target points and another is background points. In experimental results, the target-to-clutter ratio (TCR) and the receiver operating characteristics (ROC) curves are computed experimentally to compare the performances of the proposed method and other five sophisticated methods. From the results, the proposed method shows a better discrimination of targets and clutters and has a lower false alarm rate than the existing moving target detection methods.
NASA Astrophysics Data System (ADS)
Hagene, J. K.
2012-04-01
A gound based optical displacement monitoring system, "NIODIM", is being developed by Norsk Elektro Optikk in the framework of the activities of the European project "Integrated System for Transport Infrastructure surveillance and Monitoring by Electromagnetic Sensing" (ISTIMES), funded in the 7th Framework Programme (FP7/2007-2013). The optical displacement monitoring system has now participated in two real life field campaigns one in Switzerland and one in Italy. The latter, the tests in Potenza, Italy, will be presented in the following. The NIODIM system has undergone some development during the last year to adopt it for use in a somewhat higher frequency domain by changing the camera sensor part. This to make it more useful for monitoring of structures with oscillation frequencies tens of Hz. The original system was intended to a large extent to monitor land slides, quick clay and rock slides and similar phenomena typically having a relatively slow time response. The system has been significantly speeded up from the original 12 Hz. Current tests have been performed at a frame rate of 64 Hz i.e., the camera part and data processing unit have been running on 64Hz. In connection with the tests in Italy the data processing has been upgraded to include sub-pixel resolution i.e., the measurement results are no longer limited by pixel borders or single pixels. The main part of the NIODIM system is a camera capable of operating at a sufficiently high frame rate. This camera will typically be mounted on firm ground and will depict and monitor a reference point, typically a light emitting diode, LED, which will be mounted on the object susceptible to move. A processing unit will acquire the images from the camera part and find the position of the LED in the image and compare that to threshold values and if required raise a warning or an alarm. The NIODIM system can either be a standalone system or be an integrated part of the overall ISTIMES system, the ISTIMES system being a decision support system. Field trials as part of the ISTIMES project took place in Potenza, Italy, for a week in July 2011. The test target was Musmeci's bridge, a bridge with a design where aesthetic values have been just as important as traditional civil engineering aspects. Several technologies and techniques were tested at the same part of the bridge to allow for data correlation between different sensors. The camera and processing parts of the optical displacement monitoring system were mounted on a concrete wall at the one end of the bridge while the LED reference points were mounted on the bridge approximately 40 metres away. The tests at the Musmeci's bridge are successful and verifying some of the findings from the tests in Switzerland. However, we learned a lesson with regards to temporary mounting of the reference points using glossy stainless steel parts. A short period early in the morning, when illuminated by the sun, these stainless steel parts were just as bright as the LED reference point leading to potential noise in the measurements. Due to availability of the raw data this could be fixed later doing post processing on the stored data. One of the findings was that we have relatively large time of day variation that appear to be periodic with a cycle time of about 24 hours, at least with similar weather conditions. These displacements appear to be in the order of 10 mm and is probably due to thermal effects. Several shorter displacements have also been registered with amplitudes of a couple of mm and duration around 10 seconds. These shorter displacement peaks appear to be caused by heavy vehicles passing by on the bridge. The introduction of the processing using sub-pixel resolution looks very promising and appears to give a significant improvement of the actual resolution of the system. Even thought the measurements in the field are successfully completed we have noted larger slowly moving displacements than originally expected. This combined with shorter lasting peaks could lead to measurements above pre-set thresholds and could further on lead to a raised alarm. Such an alarm will most likely be regarded as a false alarm caused by the superposition of the long time constant thermal displacement and the short time constant peak possibly due to a vehicle. These results have made us re-think our system for handling warnings and alarms based on measurements done. There must be different thresholds for slow events and for quick event and the combination thereof. After taking into consideration the lessons learned our optical displacement monitoring system has potential of being a reliable and robust system solving the problem it was intended to solve. Acknowledgement: The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under Grant Agreement n° 225663.
Consequences of increasing convection onto patient care and protein removal in hemodialysis
Duranton, Flore; Guzman, Caroline; Szwarc, Ilan; Vetromile, Fernando; Cazevieille, Chantal; Brunet, Philippe; Servel, Marie-Françoise; Le Quintrec, Moglie
2017-01-01
Introduction Recent randomised controlled trials suggest that on-line hemodiafiltration (OL-HDF) improves survival, provided that it reaches high convective volumes. However, there is scant information on the feasibility and the consequences of modifying convection volumes in clinics. Methods Twelve stable dialysis patients were treated with high-flux 1.8 m2 polysulphone dialyzers and 4 levels of convection flows (QUF) based on GKD-UF monitoring of the system, for 1 week each. The consequences on dialysis delivery (transmembrane pressure (TMP), number of alarms, % of achieved prescribed convection) and efficacy (mass removal of low and high molecular weight compounds) were analysed. Results TMP increased exponentially with QUF (p<0.001 for N >56,000 monitoring values). Beyond 21 L/session, this resulted into frequent TMP alarms requiring nursing staff interventions (mean ± SEM: 10.3 ± 2.2 alarms per session, p<0.001 compared to lower convection volumes). Optimal convection volumes as assessed by GKD-UF-max were 20.6 ± 0.4 L/session, whilst 4 supplementary litres were obtained in the maximum situation (24.5 ± 0.6 L/session) but the proportion of sessions achieving the prescribed convection volume decreased from 94% to only 33% (p<0.001). Convection increased high molecular weight compound removal and shifted the membrane cut-off towards the higher molecular weight range. Conclusions Reaching high convection volumes as recommended by the recent RCTs (> 20L) is feasible by setting an HDF system at its optimal conditions based upon the GKD-UF monitoring. Prescribing higher convection volumes resulted in instability of the system, provoked alarms, was bothersome for the nursing staff and the patients, rarely achieved the prescribed convection volumes and increased removal of high molecular weight compounds, notably albumin. PMID:28166268
Consequences of increasing convection onto patient care and protein removal in hemodialysis.
Gayrard, Nathalie; Ficheux, Alain; Duranton, Flore; Guzman, Caroline; Szwarc, Ilan; Vetromile, Fernando; Cazevieille, Chantal; Brunet, Philippe; Servel, Marie-Françoise; Argilés, Àngel; Le Quintrec, Moglie
2017-01-01
Recent randomised controlled trials suggest that on-line hemodiafiltration (OL-HDF) improves survival, provided that it reaches high convective volumes. However, there is scant information on the feasibility and the consequences of modifying convection volumes in clinics. Twelve stable dialysis patients were treated with high-flux 1.8 m2 polysulphone dialyzers and 4 levels of convection flows (QUF) based on GKD-UF monitoring of the system, for 1 week each. The consequences on dialysis delivery (transmembrane pressure (TMP), number of alarms, % of achieved prescribed convection) and efficacy (mass removal of low and high molecular weight compounds) were analysed. TMP increased exponentially with QUF (p<0.001 for N >56,000 monitoring values). Beyond 21 L/session, this resulted into frequent TMP alarms requiring nursing staff interventions (mean ± SEM: 10.3 ± 2.2 alarms per session, p<0.001 compared to lower convection volumes). Optimal convection volumes as assessed by GKD-UF-max were 20.6 ± 0.4 L/session, whilst 4 supplementary litres were obtained in the maximum situation (24.5 ± 0.6 L/session) but the proportion of sessions achieving the prescribed convection volume decreased from 94% to only 33% (p<0.001). Convection increased high molecular weight compound removal and shifted the membrane cut-off towards the higher molecular weight range. Reaching high convection volumes as recommended by the recent RCTs (> 20L) is feasible by setting an HDF system at its optimal conditions based upon the GKD-UF monitoring. Prescribing higher convection volumes resulted in instability of the system, provoked alarms, was bothersome for the nursing staff and the patients, rarely achieved the prescribed convection volumes and increased removal of high molecular weight compounds, notably albumin.
The event notification and alarm system for the Open Science Grid operations center
NASA Astrophysics Data System (ADS)
Hayashi, S.; Teige and, S.; Quick, R.
2012-12-01
The Open Science Grid Operations (OSG) Team operates a distributed set of services and tools that enable the utilization of the OSG by several HEP projects. Without these services users of the OSG would not be able to run jobs, locate resources, obtain information about the status of systems or generally use the OSG. For this reason these services must be highly available. This paper describes the automated monitoring and notification systems used to diagnose and report problems. Described here are the means used by OSG Operations to monitor systems such as physical facilities, network operations, server health, service availability and software error events. Once detected, an error condition generates a message sent to, for example, Email, SMS, Twitter, an Instant Message Server, etc. The mechanism being developed to integrate these monitoring systems into a prioritized and configurable alarming system is emphasized.
Heideklang, René; Shokouhi, Parisa
2016-01-01
This article focuses on the fusion of flaw indications from multi-sensor nondestructive materials testing. Because each testing method makes use of a different physical principle, a multi-method approach has the potential of effectively differentiating actual defect indications from the many false alarms, thus enhancing detection reliability. In this study, we propose a new technique for aggregating scattered two- or three-dimensional sensory data. Using a density-based approach, the proposed method explicitly addresses localization uncertainties such as registration errors. This feature marks one of the major of advantages of this approach over pixel-based image fusion techniques. We provide guidelines on how to set all the key parameters and demonstrate the technique’s robustness. Finally, we apply our fusion approach to experimental data and demonstrate its capability to locate small defects by substantially reducing false alarms under conditions where no single-sensor method is adequate. PMID:26784200
Space debris detection in optical image sequences.
Xi, Jiangbo; Wen, Desheng; Ersoy, Okan K; Yi, Hongwei; Yao, Dalei; Song, Zongxi; Xi, Shaobo
2016-10-01
We present a high-accuracy, low false-alarm rate, and low computational-cost methodology for removing stars and noise and detecting space debris with low signal-to-noise ratio (SNR) in optical image sequences. First, time-index filtering and bright star intensity enhancement are implemented to remove stars and noise effectively. Then, a multistage quasi-hypothesis-testing method is proposed to detect the pieces of space debris with continuous and discontinuous trajectories. For this purpose, a time-index image is defined and generated. Experimental results show that the proposed method can detect space debris effectively without any false alarms. When the SNR is higher than or equal to 1.5, the detection probability can reach 100%, and when the SNR is as low as 1.3, 1.2, and 1, it can still achieve 99%, 97%, and 85% detection probabilities, respectively. Additionally, two large sets of image sequences are tested to show that the proposed method performs stably and effectively.
Entanglement-enhanced Neyman-Pearson target detection using quantum illumination
NASA Astrophysics Data System (ADS)
Zhuang, Quntao; Zhang, Zheshen; Shapiro, Jeffrey H.
2017-08-01
Quantum illumination (QI) provides entanglement-based target detection---in an entanglement-breaking environment---whose performance is significantly better than that of optimum classical-illumination target detection. QI's performance advantage was established in a Bayesian setting with the target presumed equally likely to be absent or present and error probability employed as the performance metric. Radar theory, however, eschews that Bayesian approach, preferring the Neyman-Pearson performance criterion to avoid the difficulties of accurately assigning prior probabilities to target absence and presence and appropriate costs to false-alarm and miss errors. We have recently reported an architecture---based on sum-frequency generation (SFG) and feedforward (FF) processing---for minimum error-probability QI target detection with arbitrary prior probabilities for target absence and presence. In this paper, we use our results for FF-SFG reception to determine the receiver operating characteristic---detection probability versus false-alarm probability---for optimum QI target detection under the Neyman-Pearson criterion.
Design of portable valuables touch alarm circuit
NASA Astrophysics Data System (ADS)
Li, Biqing; Li, Zhao
2017-03-01
In this paper, the name of the alarm is portable touch burglar alarm. It not only has the advantages of high sensitivity, small size and light weight, but it is easy on the trigger, the circuit is simple and easy to be implemented, besides, it works stably. This alarm is featured with simple design, convenient use, strong flexibility and reliable performance, thus it can be installed on the door or window and even can be carried on human's body. When the human body touches the metal valuables that need to be protected, the device will start the alarm equipment so as to make the bell keep ringing, and the alarm sound stops until the power is cut off.
Sensory Overload and Technology in Critical Care.
Wung, Shu-Fen; Malone, Daniel C; Szalacha, Laura
2018-06-01
In this focus group study, we identified issues associated with sensory overload from medical technology alarms/alerts for intensive care unit nurses. Participants indicated that alarms from cardiopulmonary monitors, ventilators, and intravenous pumps contributed the most to sensory overload and, yet, these alarms were also deemed the most helpful. Alerts/alarms from electronic health records and medication dispensing systems were rated low in contributing to sensory overload, as well as being the least helpful. Specific device/technology barriers, related to device alerts/alarms, are detailed. Future user-centered and integrated improvements in alarm systems associated with medical devices in the intensive care unit are needed. Copyright © 2018 Elsevier Inc. All rights reserved.
Substation alarm multiplexing system (SAMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
ElBadaly, H.; Gaughan, J.; Ward, G.
1996-03-01
This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less
Neural networks for computer-aided diagnosis: detection of lung nodules in chest radiograms.
Coppini, Giuseppe; Diciotti, Stefano; Falchini, Massimo; Villari, Natale; Valli, Guido
2003-12-01
The paper describes a neural-network-based system for the computer aided detection of lung nodules in chest radiograms. Our approach is based on multiscale processing and artificial neural networks (ANNs). The problem of nodule detection is faced by using a two-stage architecture including: 1) an attention focusing subsystem that processes whole radiographs to locate possible nodular regions ensuring high sensitivity; 2) a validation subsystem that processes regions of interest to evaluate the likelihood of the presence of a nodule, so as to reduce false alarms and increase detection specificity. Biologically inspired filters (both LoG and Gabor kernels) are used to enhance salient image features. ANNs of the feedforward type are employed, which allow an efficient use of a priori knowledge about the shape of nodules, and the background structure. The images from the public JSRT database, including 247 radiograms, were used to build and test the system. We performed a further test by using a second private database with 65 radiograms collected and annotated at the Radiology Department of the University of Florence. Both data sets include nodule and nonnodule radiographs. The use of a public data set along with independent testing with a different image set makes the comparison with other systems easier and allows a deeper understanding of system behavior. Experimental results are described by ROC/FROC analysis. For the JSRT database, we observed that by varying sensitivity from 60 to 75% the number of false alarms per image lies in the range 4-10, while accuracy is in the range 95.7-98.0%. When the second data set was used comparable results were obtained. The observed system performances support the undertaking of system validation in clinical settings.
NASA Astrophysics Data System (ADS)
Zhou, Anran; Xie, Weixin; Pei, Jihong; Chen, Yapei
2018-02-01
For ship targets detection in cluttered infrared image sequences, a robust detection method, based on the probabilistic single Gaussian model of sea background in Fourier domain, is put forward. The amplitude spectrum sequences at each frequency point of the pure seawater images in Fourier domain, being more stable than the gray value sequences of each background pixel in the spatial domain, are regarded as a Gaussian model. Next, a probability weighted matrix is built based on the stability of the pure seawater's total energy spectrum in the row direction, to make the Gaussian model more accurate. Then, the foreground frequency points are separated from the background frequency points by the model. Finally, the false-alarm points are removed utilizing ships' shape features. The performance of the proposed method is tested by visual and quantitative comparisons with others.
Liu, Ying; Holland, Amy E; Mack, Karin; Diekman, Shane
2011-10-01
Deaths from fires and burns are a leading cause of fatal home injury in the United States. Smoke alarms are one of the most effective interventions to prevent residential fire deaths. Nationwide, more than 95% of homes are estimated to have at least one smoke alarm. There is evidence that homes at highest risk of fire deaths lag behind national averages in smoke alarm use and maintenance. We compiled a comprehensive list of published studies that focus on smoke alarm prevalence in high-risk homes. Our findings show that there are substantial gaps in both smoke alarm presence and functional status between high-risk homes and national average estimates. To save more lives, improved efforts are needed to reduce the disparity in smoke alarm prevalence and functional use in the United States. Copyright © 2011 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Rushton, Erik; Ryan, Emily; Swift, Charles
After reading the story "Dear Mr. Henshaw" by Beverly Cleary, students build an alarm system for something in the classroom as the main character, Leigh, does to protect his lunchbox from thieves. Students learn about alarms and use their creativity to create an alarm system to protect their lockers, desk, or classroom door. This activity uses a…
33 CFR 155.380 - Oily water separating equipment and bilge alarm approval standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PREVENTION REGULATIONS FOR VESSELS Vessel Equipment § 155.380 Oily water separating equipment and bilge alarm approval standards. (a) On U.S. inspected ships, oily water separating equipment and bilge alarms must be... routine maintenance of the oily water separating equipment and the bilge alarm must be clearly defined by...
33 CFR 155.380 - Oily water separating equipment and bilge alarm approval standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PREVENTION REGULATIONS FOR VESSELS Vessel Equipment § 155.380 Oily water separating equipment and bilge alarm approval standards. (a) On U.S. inspected ships, oily water separating equipment and bilge alarms must be... routine maintenance of the oily water separating equipment and the bilge alarm must be clearly defined by...
33 CFR 155.380 - Oily water separating equipment and bilge alarm approval standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PREVENTION REGULATIONS FOR VESSELS Vessel Equipment § 155.380 Oily water separating equipment and bilge alarm approval standards. (a) On U.S. inspected ships, oily water separating equipment and bilge alarms must be... routine maintenance of the oily water separating equipment and the bilge alarm must be clearly defined by...
33 CFR 155.380 - Oily water separating equipment and bilge alarm approval standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PREVENTION REGULATIONS FOR VESSELS Vessel Equipment § 155.380 Oily water separating equipment and bilge alarm approval standards. (a) On U.S. inspected ships, oily water separating equipment and bilge alarms must be... routine maintenance of the oily water separating equipment and the bilge alarm must be clearly defined by...
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample... unit, fire detectors, smoke detectors, and audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. (c) Manual fire alarm systems. For the purpose of this...
False Fire Alarms: A Deviant Pattern of Seeking Help.
ERIC Educational Resources Information Center
Camblin, Louise; Weinland, Laura
1987-01-01
Discusses the phenomenon of false fire alarms, the deliberate, intentional false reporting of fires, by mentally troubled persons as a primitive kind of help-seeking behavior. Several common themes found by reviewing false alarm cases are presented. Suggests that identifying the intrapsychic dynamics of false alarm reporters could be useful in…
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
33 CFR 127.207 - Warning alarms.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Warning alarms. 127.207 Section... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.207 Warning alarms. (a) The marine... be located so that the warning alarm is not obstructed for a distance of 1.6 km (1 mile) in all...
33 CFR 127.207 - Warning alarms.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Warning alarms. 127.207 Section... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.207 Warning alarms. (a) The marine... be located so that the warning alarm is not obstructed for a distance of 1.6 km (1 mile) in all...
33 CFR 127.207 - Warning alarms.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Warning alarms. 127.207 Section... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.207 Warning alarms. (a) The marine... be located so that the warning alarm is not obstructed for a distance of 1.6 km (1 mile) in all...
33 CFR 127.207 - Warning alarms.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Warning alarms. 127.207 Section... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.207 Warning alarms. (a) The marine... be located so that the warning alarm is not obstructed for a distance of 1.6 km (1 mile) in all...
33 CFR 127.207 - Warning alarms.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Warning alarms. 127.207 Section... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.207 Warning alarms. (a) The marine... be located so that the warning alarm is not obstructed for a distance of 1.6 km (1 mile) in all...
46 CFR 78.47-75 - Ventilation alarm failure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72... FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15284, Dec. 6, 1966] ...
46 CFR 78.47-75 - Ventilation alarm failure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72... FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15284, Dec. 6, 1966] ...
46 CFR 78.47-75 - Ventilation alarm failure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72... FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15284, Dec. 6, 1966] ...
46 CFR 78.47-75 - Ventilation alarm failure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72... FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15284, Dec. 6, 1966] ...
46 CFR 78.47-75 - Ventilation alarm failure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72... FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15284, Dec. 6, 1966] ...
40 CFR 267.34 - When must personnel have access to communication equipment or an alarm system?
Code of Federal Regulations, 2010 CFR
2010-07-01
... to an internal alarm or emergency communication device, either directly or through visual or voice... communication equipment or an alarm system? 267.34 Section 267.34 Protection of Environment ENVIRONMENTAL... have access to communication equipment or an alarm system? (a) Whenever hazardous waste is being poured...
Code of Federal Regulations, 2010 CFR
2010-10-01
... than paint and lamp lockers and similar small spaces, shall be fitted with an approved audible alarm in... required to be fitted with a delayed discharge. Such alarms shall be so arranged as to sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and the alarm shall depend...
Application of the PageRank Algorithm to Alarm Graphs
NASA Astrophysics Data System (ADS)
Treinen, James J.; Thurimella, Ramakrishna
The task of separating genuine attacks from false alarms in large intrusion detection infrastructures is extremely difficult. The number of alarms received in such environments can easily enter into the millions of alerts per day. The overwhelming noise created by these alarms can cause genuine attacks to go unnoticed. As means of highlighting these attacks, we introduce a host ranking technique utilizing Alarm Graphs. Rather than enumerate all potential attack paths as in Attack Graphs, we build and analyze graphs based on the alarms generated by the intrusion detection sensors installed on a network. Given that the alarms are predominantly false positives, the challenge is to identify, separate, and ideally predict future attacks. In this paper, we propose a novel approach to tackle this problem based on the PageRank algorithm. By elevating the rank of known attackers and victims we are able to observe the effect that these hosts have on the other nodes in the Alarm Graph. Using this information we are able to discover previously overlooked attacks, as well as defend against future intrusions.
DiGuiseppi, Carolyn; Roberts, Ian; Wade, Angie; Sculpher, Mark; Edwards, Phil; Godward, Catherine; Pan, Huiqi; Slater, Suzanne
2002-11-02
To measure the effect of giving out free smoke alarms on rates of fires and rates of fire related injury in a deprived multiethnic urban population. Cluster randomised controlled trial. Forty electoral wards in two boroughs of inner London, United Kingdom. Primarily households including elderly people or children and households that are in housing rented from the borough council. 20 050 smoke alarms, fittings, and educational brochures distributed free and installed on request. Rates of fires and related injuries during two years after the distribution; alarm ownership, installation, and function. Giving out free smoke alarms did not reduce injuries related to fire (rate ratio 1.3; 95% confidence interval 0.9 to 1.9), admissions to hospital and deaths (1.3; 0.7 to 2.3), or fires attended by the fire brigade (1.1; 0.96 to 1.3). Similar proportions of intervention and control households had installed alarms (36/119 (30%) v 35/109 (32%); odds ratio 0.9; 95% confidence interval 0.5 to 1.7) and working alarms (19/118 (16%) v 18/108 (17%); 0.9; 0.4 to 1.8). Giving out free smoke alarms in a deprived, multiethnic, urban community did not reduce injuries related to fire, mostly because few alarms had been installed or were maintained.
The "Let's Get Alarmed!" initiative: a smoke alarm giveaway programme.
DiGuiseppi, C; Slater, S; Roberts, I; Adams, L; Sculpher, M; Wade, A; McCarthy, M
1999-09-01
To reduce fires and fire related injuries by increasing the prevalence of functioning smoke alarms in high risk households. The programme was delivered in an inner London area with above average material deprivation and below average smoke alarm ownership. The target population included low income and rental households and households with elderly persons or young children. Forty wards, averaging 4000 households each, were randomised to intervention or control status. Free smoke alarms and fire safety information were distributed in intervention wards by community groups and workers as part of routine activities and by paid workers who visited target neighbourhoods. Recipients provided data on household age distribution and housing tenure. Programme costs were documented from a societal perspective. Data are being collected on smoke alarm ownership and function, and on fires and related injuries and their costs. Community and paid workers distributed 20,050 smoke alarms, potentially sufficient to increase smoke alarm ownership by 50% in intervention wards. Compared with the total study population, recipients included greater proportions of low income and rental households and households including children under 5 years or adults aged 65 and older. Total programme costs were 145,087 Pounds. It is possible to implement a large scale smoke alarm giveaway programme targeted to high risk households in a densely populated, multicultural, materially deprived community. The programme's effects on the prevalence of installed and functioning alarms and the incidence of fires and fire related injuries, and its cost effectiveness, are being evaluated as a randomized controlled trial.
Differences in alarm events between disposable and reusable electrocardiography lead wires.
Albert, Nancy M; Murray, Terri; Bena, James F; Slifcak, Ellen; Roach, Joel D; Spence, Jackie; Burkle, Alicia
2015-01-01
Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. To examine differences in alarm events between disposable and reusable ECG-LWs. Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, assessed frequency and type of alarm events by using total counts and rates per 100 patient days. Event rates were compared by using generalized linear mixed-effect models for differences and noninferiority between wire types. In 1611 patients and 9385.5 patient days of ECG monitoring, patient characteristics were similar between groups. Rates of alarms for no telemetry, leads fail, or leads off were lower in disposable ECG-LWs (adjusted relative risk [95% CI], 0.71 [0.53-0.96]; noninferiority P < .001; superiority P = .03) and monitoring (artifact) alarms were significantly noninferior (adjusted relative risk [95% CI]: 0.88, [0.62-1.24], P = .02; superiority P = .44). No between-group differences existed in false or true crisis alarms. Disposable ECG-LWs were noninferior to reusable ECG-LWs for all false-alarm events (N [rate per 100 patient days], disposable 2029 [79.1] vs reusable 6673 [97.9]; adjusted relative risk [95% CI]: 0.81 [0.63-1.06], P = .002; superiority P = .12.) Disposable ECG-LWs with patented push-button design had superior performance in reducing alarms created by no telemetry, leads fail, or leads off and significant noninferiority in all false-alarm rates compared with reusable ECG-LWs. Fewer ECG alarms may save nurses time, decrease alarm fatigue, and improve patient safety. ©2015 American Association of Critical-Care Nurses.
Lessons learned from an emergency medical services fire safety intervention.
Pirrallo, Ronald G; Cady, Charles E
2004-01-01
The authors conducted a pilot study, finding that many households that experienced fires had received prior emergency medical services (EMS) visits, but few had operational smoke alarms. The study hypothesis is that dwellings that received smoke alarms and/or batteries during an EMS call were more likely to have an operational alarm, less property dollar loss, and decreased morbidity and mortality at the time of a subsequent fire. Smoke detectors and batteries were provided to an urban fire department for placement in unprotected homes at the time of an EMS call from March 1, 1999, through January 31, 2001. After addressing the reason for the 911 EMS call, verification or installation of an operational smoke alarm was performed. The authors examined records for dwellings that had a subsequent fire for outcomes of smoke alarm status, estimated property dollar loss, and number of injuries and fatalities. This program placed 1,335 smoke detectors. Of these, 99 dwellings were found to have a fire or smoke condition with 20 exclusions. Our final number was 79; 28 (35%) still had an operating smoke alarm. In homes with operational alarms, the mean dollar loss was 2,870 dollars (U.S. 2001) (95% confidence interval [CI], 143-5,596). In homes without operational alarms, mean loss was 10,468 dollars (U.S. 2001) (95% CI, 5,875-15,061). No injuries or fatalities occurred in either group. This program was successful in placing 1,335 smoke alarms in at-risk dwellings and reaffirmed that an operational smoke alarm significantly decreases property dollar loss. However, if the goal is to have all homes protected by smoke alarms, this program has long-term effectiveness limitations.
McFarlane, Daniel C; Doig, Alexa K; Agutter, James A; Brewer, Lara M; Syroid, Noah D; Mittu, Ranjeev
2018-01-01
This study evaluates the potential for improving patient safety by introducing a metacognitive attention aid that enables clinicians to more easily access and use existing alarm/alert information. It is hypothesized that this introduction will enable clinicians to easily triage alarm/alert events and quickly recognize emergent opportunities to adapt care delivery. The resulting faster response to clinically important alarms/alerts has the potential to prevent adverse events and reduce healthcare costs. A randomized within-subjects single-factor clinical experiment was conducted in a high-fidelity 20-bed simulated acute care hospital unit. Sixteen registered nurses, four at a time, cared for five simulated patients each. A two-part highly realistic clinical scenario was used that included representative: tasking; information; and alarms/alerts. The treatment condition introduced an integrated wearable attention aid that leveraged metacognition methods from proven military systems. The primary metric was time for nurses to respond to important alarms/alerts. Use of the wearable attention aid resulted in a median relative within-subject improvement for individual nurses of 118% (W = 183, p = 0.006). The top quarter of relative improvement was 3,303% faster (mean; 17.76 minutes reduced to 1.33). For all unit sessions, there was an overall 148% median faster response time to important alarms (8.12 minutes reduced to 3.27; U = 2.401, p = 0.016), with 153% median improvement in consistency across nurses (F = 11.670, p = 0.001). Existing device-centric alarm/alert notification solutions can require too much time and effort for nurses to access and understand. As a result, nurses may ignore alarms/alerts as they focus on other important work. There has been extensive research on reducing alarm frequency in healthcare. However, alarm safety remains a top problem. Empirical observations reported here highlight the potential of improving patient safety by supporting the meta-work of checking alarms.
Doig, Alexa K.; Agutter, James A.; Brewer, Lara M.; Syroid, Noah D.; Mittu, Ranjeev
2018-01-01
Objective This study evaluates the potential for improving patient safety by introducing a metacognitive attention aid that enables clinicians to more easily access and use existing alarm/alert information. It is hypothesized that this introduction will enable clinicians to easily triage alarm/alert events and quickly recognize emergent opportunities to adapt care delivery. The resulting faster response to clinically important alarms/alerts has the potential to prevent adverse events and reduce healthcare costs. Materials and methods A randomized within-subjects single-factor clinical experiment was conducted in a high-fidelity 20-bed simulated acute care hospital unit. Sixteen registered nurses, four at a time, cared for five simulated patients each. A two-part highly realistic clinical scenario was used that included representative: tasking; information; and alarms/alerts. The treatment condition introduced an integrated wearable attention aid that leveraged metacognition methods from proven military systems. The primary metric was time for nurses to respond to important alarms/alerts. Results Use of the wearable attention aid resulted in a median relative within-subject improvement for individual nurses of 118% (W = 183, p = 0.006). The top quarter of relative improvement was 3,303% faster (mean; 17.76 minutes reduced to 1.33). For all unit sessions, there was an overall 148% median faster response time to important alarms (8.12 minutes reduced to 3.27; U = 2.401, p = 0.016), with 153% median improvement in consistency across nurses (F = 11.670, p = 0.001). Discussion and conclusion Existing device-centric alarm/alert notification solutions can require too much time and effort for nurses to access and understand. As a result, nurses may ignore alarms/alerts as they focus on other important work. There has been extensive research on reducing alarm frequency in healthcare. However, alarm safety remains a top problem. Empirical observations reported here highlight the potential of improving patient safety by supporting the meta-work of checking alarms. PMID:29768477
Interventions for promoting smoke alarm ownership and function.
DiGuiseppi, C; Higgins, J P
2001-01-01
Residential fires caused at least 67 deaths and 2,500 non-fatal injuries to children aged 0-16 in the United Kingdom in 1998. Smoke alarm ownership is associated with a reduced risk of residential fire death. We evaluated interventions to promote residential smoke alarms, to assess their effect on smoke alarm ownership, smoke alarm function, fires and burns and other fire-related injuries. We searched the Cochrane Controlled Trials Register, Cochrane Injuries Group database, MEDLINE, EMBASE, PsycLIT, CINAHL, ERIC, Dissertation Abstracts, International Bibliography of Social Sciences, ISTP, FIREDOC and LRC. Conference proceedings, published case studies, and bibliographies were systematically searched, and investigators and relevant organisations were contacted, to identify trials. Randomised, quasi-randomised or nonrandomised controlled trials completed or published after 1969 evaluating an intervention to promote residential smoke alarms. Two reviewers independently extracted data and assessed trial quality. We identified 26 trials, of which 13 were randomised. Overall, counselling and educational interventions had only a modest effect on the likelihood of owning an alarm (OR=1.26; 95% CI: 0.87 to 1.82) or having a functional alarm (OR=1.19; 0.85 to 1.66). Counselling as part of primary care child health surveillance had greater effects on ownership (OR=1.96; 1.03 to 3.72) and function (OR=1.72; 0.78 to 3.80). Results were sensitive to trial quality, however, and effects on fire-related injuries were not reported. In two non randomised trials, direct provision of free alarms significantly increased functioning alarms and reduced fire-related injuries. Media and community education showed little benefit in non randomised trials. Counselling as part of child health surveillance may increase smoke alarm ownership and function, but its effects on injuries are unevaluated. Community smoke alarm give-away programmes apparently reduce fire-related injuries, but these trials were not randomised and results must be interpreted cautiously. Further efforts to promote smoke alarms in primary care or through give-away programmes should be evaluated by adequately designed randomised controlled trials measuring injury outcomes.
ERIC Educational Resources Information Center
Andelora, Jeffrey T.
2013-01-01
In the author's fifteen years as a subscriber to "TETYC," he has yet to read an article as alarming as Keith Kroll's "The End of the Community College English Profession." His argument that neoliberalism--a political ideology and set of economic policies that look to the free market and privatization for answers to questions great and small--is…
ERIC Educational Resources Information Center
Columbia Univ., New York, NY. National Center on Addiction and Substance Abuse.
Illegal drug use by adolescents is on the rise. This alarming trend was quantified in this national survey of the attitudes of teens and their parents (1,200 teens and 1,166 parents, including 819 sets of teens and parents from the same households) towards cigarettes, alcohol, inhalants, marijuana, LSD, cocaine, heroin, and other illegal drugs.…
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15... the end of the 5-minute period an oil content reading is obtained and recorded. (2) The bilge alarm is... concentration of iron oxide. Any change in the bilge alarm reading during the 5 minutes is recorded. (3) Repeat...
46 CFR 108.627 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 108.627 Section 108.627 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide and clean agent alarms. Each carbon dioxide alarm must be...
46 CFR 108.627 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 108.627 Section 108.627 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide and clean agent alarms. Each carbon dioxide alarm must be...
46 CFR 97.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN...
46 CFR 108.627 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 108.627 Section 108.627 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide and clean agent alarms. Each carbon dioxide alarm must be...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 153.409 - High level alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false High level alarms. 153.409 Section 153.409 Shipping... Systems § 153.409 High level alarms. When Table 1 refers to this section or requires a cargo to have a closed gauging system, the cargo's containment system must have a high level alarm: (a) That gives an...
46 CFR 119.530 - Bilge high level alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge high level alarms. 119.530 Section 119.530... Bilge and Ballast Systems § 119.530 Bilge high level alarms. (a) Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following...
Low Voltage Alarm Apprenticeship. Related Training Modules. 0.1 History of Alarms.
ERIC Educational Resources Information Center
Lane Community Coll., Eugene, OR.
This packet of one learning module on the history of alarms is one of eight such packets developed for apprenticeship training for low voltage alarm. Introductory materials are a complete listing of all available modules and a supplementary reference list. Each module contains some or all of these components: goal, performance indicators, study…
Low Voltage Alarm Apprenticeship. Related Training Modules. 7.1-26.10 Alarm Basics.
ERIC Educational Resources Information Center
Lane Community Coll., Eugene, OR.
This packet of 70 learning modules on alarm basics is 1 of 8 such packets developed for apprenticeship training for low voltage alarm. Introductory materials are a complete listing of all available modules and a supplementary reference list. Each module contains some or all of these components: goal, performance indicators, study guide (a check…
Justus, Alan L
2015-05-01
This paper presents technically-based techniques to deal with nuisance personnel contamination monitor (PCM) alarms. The techniques derive from the fundamental physical characteristics of radon progeny. Some PCM alarms, although valid alarms and not actually "false," could be due to nuisance naturally-occurring radionuclides (i.e., radon progeny). Based on certain observed characteristics of the radon progeny, several prompt techniques are discussed that could either remediate or at least mitigate the problem of nuisance alarms. Examples are provided which demonstrate the effective use of the techniques.
Realization of time keeping alarming system based on CTI technique
NASA Astrophysics Data System (ADS)
Cai, Cheng-Lin; Dong, Shao-Wu
2003-12-01
An application of CTI (Computer Telephone Integration) technique to fault alarming in time keeping system is presented in this paper. Two key parts of this alarming system, telephone phonic card and TTS (Text To Speech) are briefly introduced. A series of events and methods for programming interface based on ActiveX control (phonic.OCX) is discussed, and an alarming program module is developed. The alarming program module can be used in reporting accidents for time keeping system, and can also be applied to power supply system and environmental monitoring system.
Infrastructure Tsunami Could Easily Dwarf Climate Change
NASA Astrophysics Data System (ADS)
Lansing, Stephen
Compared to the physical and biological sciences, so far complexity has had far less impact on mainstream social science. This is not surprising, but it is alarming because we find ourselves in the midst of a planetary-scale transition from the Holocene to the Anthropocene. We have already breached some planetary boundaries for sustainability, but those tipping points are nearly invisible from the perspective of the linear equilibrium models that continue to hold sway in social science...
Military Role in Countering Terrorist Use of Weapons of Mass Destruction
1999-04-01
chemical and biological mobile point detection. “The M21 Remote Sensing Chemical Agent Alarm (RSCAAL) is an automatic scanning, passive infrared sensor...The M21 detects nerve and blister agent clouds based on changes in the background infrared spectra caused by the presence of the agent vapor.”15...required if greater than 3 years since last vaccine. VEE Yes Multiple vaccines required. VHF No Botulism Yes SEB No Ricin No Mycotoxin s No Source
Background suppression of infrared small target image based on inter-frame registration
NASA Astrophysics Data System (ADS)
Ye, Xiubo; Xue, Bindang
2018-04-01
We propose a multi-frame background suppression method for remote infrared small target detection. Inter-frame information is necessary when the heavy background clutters make it difficult to distinguish real targets and false alarms. A registration procedure based on points matching in image patches is used to compensate the local deformation of background. Then the target can be separated by background subtraction. Experiments show our method serves as an effective preliminary of target detection.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. Senate Committee on Governmental Affairs.
This document presents witness testimonies addressing the growing problem of Ecstasy use among American youth. All accounts point to the fact that youth are increasingly experimenting with the drug and experiencing seizures and other adverse affects at an alarming rate. Opening statements from Senators Lieberman, Bunning, and Akaka related the…
Presenting a model for dynamic facial expression changes in detecting drivers' drowsiness.
Karchani, Mohsen; Mazloumi, Adel; Saraji, Gebraeil Nasl; Gharagozlou, Faramarz; Nahvi, Ali; Haghighi, Khosro Sadeghniiat; Abadi, Bahador Makki; Foroshani, Abbas Rahimi
2015-01-01
Drowsiness while driving is a major cause of accidents. A driver fatigue detection system that is designed to sound an alarm, when appropriate, can prevent many accidents that sometime leads to the loss of life and property. In this paper, we classify drowsiness detection sensors and their strong and weak points. A compound model is proposed that uses image processing techniques to study the dynamic changes of the face to recognize drowsiness during driving.
Network Algorithms for Detection of Radiation Sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, Nageswara S; Brooks, Richard R; Wu, Qishi
In support of national defense, Domestic Nuclear Detection Office s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) amore » notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2 *2 NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.« less
Pilot Study of a Novel Partnership for Installing Smoke Alarms.
Omaki, Elise C; Frattaroli, Shannon; Shields, Wendy C; McDonald, Eileen M; Rizzutti, Nicholas; Appy, Meri-K; Voiles, Denise; Jamison, Shelly; Gielen, Andrea C
2018-02-07
Objectives To demonstrate the feasibility of partnering fire department personnel and home visiting nurses to increase the number of low-income homes protected by smoke alarms. Methods During a regularly scheduled home visit, nurses at the Nurse-Family Partnership of Maricopa County (NFP) informed their clients about an opportunity to have smoke alarms installed in their homes for free. For interested families, nurses sent a referral to the Phoenix Fire Department (PFD), scheduled an appointment, and accompanied the PFD volunteers during the installation. During the appointment, PFD personnel installed alarms and provided safety education. Clients completed a follow-up survey 1-3 months after the installation visit. In-depth interviews were completed with key informants from NFP and PFD to solicit feedback on the program. Results Fifty-two smoke alarm installation visits were completed. Before the fire department arrived, 55% of homes had no working smoke alarm. Almost all (94%) homes received at least one new smoke alarm, and every home had at least one working smoke alarm at the end of the fire department visit. At follow-up, all homes maintained at least one working smoke alarm. Members from both organizations were enthusiastic about, and supportive of the project. NFP nurses appreciated the skill and knowledge of the firefighters; PFD representatives noted that the nurses' relationships with clients made it easier for them to gain access to families who are often described as "hard-to-reach". Conclusions Partnering home visiting nurses and fire departments can be successful to increase the number of vulnerable homes with smoke alarms.
Persistent Females and Compliant Males Coordinate Alarm Calling in Diana Monkeys.
Stephan, Claudia; Zuberbühler, Klaus
2016-11-07
Sexual dimorphisms in animal vocal behavior have been successfully explained by sexual selection theory (e.g., mammals [1-5]; birds [6, 7]; anurans [8, 9]), but this does not usually include alarm calls, which are thought to be the product of kin or individual selection (e.g., [10, 11]). Here, we present the results of playback experiments with wild Diana monkeys, a species with highly dimorphic predator-specific alarms, to investigate the communication strategies of males and females during predator encounters. First, we simulated predator presence by broadcasting vocalizations of their main predators, leopards or eagles. We found that males only produced predator-specific alarms after the females had produced theirs, in response to which the females ceased alarm calling. In a second experiment, we created congruent and incongruent situations, so that the calls of a predator were followed by playbacks of male or female alarms with a matching or mismatching referent. For congruent conditions, results were the same as in the first experiment. For incongruent conditions, however, the males always gave predator-specific alarms that referentially matched the females' calls, regardless of the previously displayed predator. In contrast, females always gave predator-specific alarms that matched the predator type, regardless of their own male's subsequent calls. Moreover, the females persistently continued to alarm call until their own male produced calls with the matching referent. Results show that males and females attend to the informational content of each other's alarm calls but prioritize them differently relative to an experienced external event, a likely reflection of different underlying selection pressures. Copyright © 2016 Elsevier Ltd. All rights reserved.
Judging the urgency of non-verbal auditory alarms: a case study.
Arrabito, G Robert; Mondor, Todd; Kent, Kimberley
2004-06-22
When designed correctly, non-verbal auditory alarms can convey different levels of urgency to the aircrew, and thereby permit the operator to establish the appropriate level of priority to address the alarmed condition. The conveyed level of urgency of five non-verbal auditory alarms presently used in the Canadian Forces CH-146 Griffon helicopter was investigated. Pilots of the CH-146 Griffon helicopter and non-pilots rated the perceived urgency of the signals using a rating scale. The pilots also ranked the urgency of the alarms in a post-experiment questionnaire to reflect their assessment of the actual situation that triggers the alarms. The results of this investigation revealed that participants' ratings of perceived urgency appear to be based on the acoustic properties of the alarms which are known to affect the listener's perceived level of urgency. Although for 28% of the pilots the mapping of perceived urgency to the urgency of their perception of the triggering situation was statistically significant for three of the five alarms, the overall data suggest that the triggering situations are not adequately conveyed by the acoustic parameters inherent in the alarms. The pilots' judgement of the triggering situation was intended as a means of evaluating the reliability of the alerting system. These data will subsequently be discussed with respect to proposed enhancements in alerting systems as it relates to addressing the problem of phase of flight. These results call for more serious consideration of incorporating situational awareness in the design and assignment of auditory alarms in aircraft.
Sequence and batch language programs and alarm-related ``C`` programs for the 242-A MCS. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, J.F.
1995-03-01
A Distributive Process Control system was purchased by Project B-534, ``242-A Evaporator/Crystallizer Upgrades``. This control system, called the Monitor and Control System (MCS), was installed in the 242-A Evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict themore » overall process. To do this, WTSE developed a second alarm scheme which uses special programs, annunciator keys, and process graphics. The special programs are written in two languages; Sequence and Batch Language (SABL), and ``C`` language. The WTSE-developed alarm scheme works as described below: SABL relates signals and alarms to the annunciator keys, called SKID keys. When an alarm occurs, a SABL program causes a SKID key to flash, and if the alarm is of yellow or white priority then a ``C`` program turns on an audible horn (the D/3 system uses a different audible horn for the red priority alarms). The horn and flashing key draws the attention of the operator.« less
Risk and return: evaluating Reverse Tracing of Precursors earthquake predictions
NASA Astrophysics Data System (ADS)
Zechar, J. Douglas; Zhuang, Jiancang
2010-09-01
In 2003, the Reverse Tracing of Precursors (RTP) algorithm attracted the attention of seismologists and international news agencies when researchers claimed two successful predictions of large earthquakes. These researchers had begun applying RTP to seismicity in Japan, California, the eastern Mediterranean and Italy; they have since applied it to seismicity in the northern Pacific, Oregon and Nevada. RTP is a pattern recognition algorithm that uses earthquake catalogue data to declare alarms, and these alarms indicate that RTP expects a moderate to large earthquake in the following months. The spatial extent of alarms is highly variable and each alarm typically lasts 9 months, although the algorithm may extend alarms in time and space. We examined the record of alarms and outcomes since the prospective application of RTP began, and in this paper we report on the performance of RTP to date. To analyse these predictions, we used a recently developed approach based on a gambling score, and we used a simple reference model to estimate the prior probability of target earthquakes for each alarm. Formally, we believe that RTP investigators did not rigorously specify the first two `successful' predictions in advance of the relevant earthquakes; because this issue is contentious, we consider analyses with and without these alarms. When we included contentious alarms, RTP predictions demonstrate statistically significant skill. Under a stricter interpretation, the predictions are marginally unsuccessful.
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...