Functional relationship-based alarm processing system
Corsberg, D.R.
1988-04-22
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary. 12 figs.
Functional relationship-based alarm processing system
Corsberg, Daniel R.
1989-01-01
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.
Functional relationship-based alarm processing
Corsberg, Daniel R.
1988-01-01
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously oupdated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on caussal factors between two alarms); (3) required action (system response or action) expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.
Functional relationship-based alarm processing
Corsberg, D.R.
1987-04-13
A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). 11 figs.
Realization of time keeping alarming system based on CTI technique
NASA Astrophysics Data System (ADS)
Cai, Cheng-Lin; Dong, Shao-Wu
2003-12-01
An application of CTI (Computer Telephone Integration) technique to fault alarming in time keeping system is presented in this paper. Two key parts of this alarming system, telephone phonic card and TTS (Text To Speech) are briefly introduced. A series of events and methods for programming interface based on ActiveX control (phonic.OCX) is discussed, and an alarming program module is developed. The alarming program module can be used in reporting accidents for time keeping system, and can also be applied to power supply system and environmental monitoring system.
Hypoglycemia alarm enhancement using data fusion.
Skladnev, Victor N; Tarnavskii, Stanislav; McGregor, Thomas; Ghevondian, Nejhdeh; Gourlay, Steve; Jones, Timothy W
2010-01-01
The acceptance of closed-loop blood glucose (BG) control using continuous glucose monitoring systems (CGMS) is likely to improve with enhanced performance of their integral hypoglycemia alarms. This article presents an in silico analysis (based on clinical data) of a modeled CGMS alarm system with trained thresholds on type 1 diabetes mellitus (T1DM) patients that is augmented by sensor fusion from a prototype hypoglycemia alarm system (HypoMon). This prototype alarm system is based on largely independent autonomic nervous system (ANS) response features. Alarm performance was modeled using overnight BG profiles recorded previously on 98 T1DM volunteers. These data included the corresponding ANS response features detected by HypoMon (AiMedics Pty. Ltd.) systems. CGMS data and alarms were simulated by applying a probabilistic model to these overnight BG profiles. The probabilistic model developed used a mean response delay of 7.1 minutes, measurement error offsets on each sample of +/- standard deviation (SD) = 4.5 mg/dl (0.25 mmol/liter), and vertical shifts (calibration offsets) of +/- SD = 19.8 mg/dl (1.1 mmol/liter). Modeling produced 90 to 100 simulated measurements per patient. Alarm systems for all analyses were optimized on a training set of 46 patients and evaluated on the test set of 56 patients. The split between the sets was based on enrollment dates. Optimization was based on detection accuracy but not time to detection for these analyses. The contribution of this form of data fusion to hypoglycemia alarm performance was evaluated by comparing the performance of the trained CGMS and fused data algorithms on the test set under the same evaluation conditions. The simulated addition of HypoMon data produced an improvement in CGMS hypoglycemia alarm performance of 10% at equal specificity. Sensitivity improved from 87% (CGMS as stand-alone measurement) to 97% for the enhanced alarm system. Specificity was maintained constant at 85%. Positive predictive values on the test set improved from 61 to 66% with negative predictive values improving from 96 to 99%. These enhancements were stable within sensitivity analyses. Sensitivity analyses also suggested larger performance increases at lower CGMS alarm performance levels. Autonomic nervous system response features provide complementary information suitable for fusion with CGMS data to enhance nocturnal hypoglycemia alarms. 2010 Diabetes Technology Society.
Hypoglycemia early alarm systems based on recursive autoregressive partial least squares models.
Bayrak, Elif Seyma; Turksoy, Kamuran; Cinar, Ali; Quinn, Lauretta; Littlejohn, Elizabeth; Rollins, Derrick
2013-01-01
Hypoglycemia caused by intensive insulin therapy is a major challenge for artificial pancreas systems. Early detection and prevention of potential hypoglycemia are essential for the acceptance of fully automated artificial pancreas systems. Many of the proposed alarm systems are based on interpretation of recent values or trends in glucose values. In the present study, subject-specific linear models are introduced to capture glucose variations and predict future blood glucose concentrations. These models can be used in early alarm systems of potential hypoglycemia. A recursive autoregressive partial least squares (RARPLS) algorithm is used to model the continuous glucose monitoring sensor data and predict future glucose concentrations for use in hypoglycemia alarm systems. The partial least squares models constructed are updated recursively at each sampling step with a moving window. An early hypoglycemia alarm algorithm using these models is proposed and evaluated. Glucose prediction models based on real-time filtered data has a root mean squared error of 7.79 and a sum of squares of glucose prediction error of 7.35% for six-step-ahead (30 min) glucose predictions. The early alarm systems based on RARPLS shows good performance. A sensitivity of 86% and a false alarm rate of 0.42 false positive/day are obtained for the early alarm system based on six-step-ahead predicted glucose values with an average early detection time of 25.25 min. The RARPLS models developed provide satisfactory glucose prediction with relatively smaller error than other proposed algorithms and are good candidates to forecast and warn about potential hypoglycemia unless preventive action is taken far in advance. © 2012 Diabetes Technology Society.
Hypoglycemia Early Alarm Systems Based on Recursive Autoregressive Partial Least Squares Models
Bayrak, Elif Seyma; Turksoy, Kamuran; Cinar, Ali; Quinn, Lauretta; Littlejohn, Elizabeth; Rollins, Derrick
2013-01-01
Background Hypoglycemia caused by intensive insulin therapy is a major challenge for artificial pancreas systems. Early detection and prevention of potential hypoglycemia are essential for the acceptance of fully automated artificial pancreas systems. Many of the proposed alarm systems are based on interpretation of recent values or trends in glucose values. In the present study, subject-specific linear models are introduced to capture glucose variations and predict future blood glucose concentrations. These models can be used in early alarm systems of potential hypoglycemia. Methods A recursive autoregressive partial least squares (RARPLS) algorithm is used to model the continuous glucose monitoring sensor data and predict future glucose concentrations for use in hypoglycemia alarm systems. The partial least squares models constructed are updated recursively at each sampling step with a moving window. An early hypoglycemia alarm algorithm using these models is proposed and evaluated. Results Glucose prediction models based on real-time filtered data has a root mean squared error of 7.79 and a sum of squares of glucose prediction error of 7.35% for six-step-ahead (30 min) glucose predictions. The early alarm systems based on RARPLS shows good performance. A sensitivity of 86% and a false alarm rate of 0.42 false positive/day are obtained for the early alarm system based on six-step-ahead predicted glucose values with an average early detection time of 25.25 min. Conclusions The RARPLS models developed provide satisfactory glucose prediction with relatively smaller error than other proposed algorithms and are good candidates to forecast and warn about potential hypoglycemia unless preventive action is taken far in advance. PMID:23439179
Design of remote car anti-theft system based on ZigBee
NASA Astrophysics Data System (ADS)
Fang, Hong; Yan, GangFeng; Li, Hong Lian
2015-12-01
A set of remote car anti-theft system based on ZigBee and GPRS with ARM11 built-in chip S3C6410 as the controller is designed. This system can detect the alarm information of the car with vibration sensor, pyroelectric sensor and infrared sensor. When the sensor detects any alarm signal, the ZigBee node in sleep will be awakened and then directly send the alarm signal to the microcontroller chip S3C6410 in the control room of the parking lot through ZigBee wireless transceiver module. After S3C6410 processes and analyzes the alarm signal, when any two sensors of the three collect the alarm signal, the LCD will display and generate an alarm and meanwhile it will send the alarm signal to the phone of the user in a wireless manner through the form of short message through GPRS module. Thus, the wireless remote monitoring of the system is realized.
Perimeter security alarm system based on fiber Bragg grating
NASA Astrophysics Data System (ADS)
Zhang, Cui; Wang, Lixin
2010-11-01
With the development of the society and economy and the improvement of living standards, people need more and more pressing security. Perimeter security alarm system is widely regarded as the first line of defense. A highly sensitive Fiber Bragg grating (FBG) vibration sensor based on the theory of the string vibration, combined with neural network adaptive dynamic programming algorithm for the perimeter security alarm system make the detection intelligently. Intelligent information processing unit identify the true cause of the vibration of the invasion or the natural environment by analyzing the frequency of vibration signals, energy, amplitude and duration. Compared with traditional perimeter security alarm systems, such as infrared perimeter security system and electric fence system, FBG perimeter security alarm system takes outdoor passive structures, free of electromagnetic interference, transmission distance through optical fiber can be as long as 20 km It is able to detect the location of event within short period of time (high-speed response, less than 3 second).This system can locate the fiber cable's breaking sites and alarm automatically if the cable were be cut. And the system can prevent effectively the false alarm from small animals, birds, strong wind, scattering things, snowfalls and vibration of sensor line itself. It can also be integrated into other security systems. This system can be widely used in variety fields such as military bases, nuclear sites, airports, warehouses, prisons, residence community etc. It will be a new force of perimeter security technology.
Talking Fire Alarms Calm Kids.
ERIC Educational Resources Information Center
Executive Educator, 1984
1984-01-01
The new microprocessor-based fire alarm systems can help to control smoke movement throughout school buildings by opening vents and doors, identify the burning section, activate voice alarms, provide firefighters with telephone systems during the fire, and release fire-preventing gas. (KS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Karen S; Kasemir, Kay
2009-01-01
An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits.more » In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.« less
An experimental investigation of the effects of alarm processing and display on operator performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Hara, J.; Brown, W.; Hallbert, B.
1998-03-01
This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluatemore » the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance, operator task performance, situation awareness, and workload were obtained. In addition, operator opinions and evaluations of the alarm processing and display conditions were collected. No deficient performance was observed in any of the experimental conditions, providing confirmatory support for many design review guidelines. The operators identified numerous strengths and weaknesses associated with individual alarm design characteristics.« less
Fault Diagnosis with Multi-State Alarms in a Nuclear Power Control Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuart A. Ragsdale; Roger Lew; Ronald L. Boring
2014-09-01
This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effects of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized the use of three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. Sensitivity and criterion based on the Signal Detection Theory were used to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed bettermore » and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.« less
[Research on the Clinical Alarm Management Mechanism Based on Closed-loop Control Theory].
Lin, Zhongkuan; Zheng, Kun; Shen, Yunming; Wu, Yunyun
2018-05-30
This paper proposes a clinical alarm management system based on the theory of the closed loop control. The alarm management mechanism can be divided into the expected standard, improving execution rule, rule execution, medical devices with alarm functions, results analysis strategy and the output link. And, we make relevant application and discussion. Results showed that the mechanism can be operable and effective.
NASA Astrophysics Data System (ADS)
Mahmoud, Seedahmed S.; Visagathilagar, Yuvaraja; Katsifolis, Jim
2012-09-01
The success of any perimeter intrusion detection system depends on three important performance parameters: the probability of detection (POD), the nuisance alarm rate (NAR), and the false alarm rate (FAR). The most fundamental parameter, POD, is normally related to a number of factors such as the event of interest, the sensitivity of the sensor, the installation quality of the system, and the reliability of the sensing equipment. The suppression of nuisance alarms without degrading sensitivity in fiber optic intrusion detection systems is key to maintaining acceptable performance. Signal processing algorithms that maintain the POD and eliminate nuisance alarms are crucial for achieving this. In this paper, a robust event classification system using supervised neural networks together with a level crossings (LCs) based feature extraction algorithm is presented for the detection and recognition of intrusion and non-intrusion events in a fence-based fiber-optic intrusion detection system. A level crossings algorithm is also used with a dynamic threshold to suppress torrential rain-induced nuisance alarms in a fence system. Results show that rain-induced nuisance alarms can be suppressed for rainfall rates in excess of 100 mm/hr with the simultaneous detection of intrusion events. The use of a level crossing based detection and novel classification algorithm is also presented for a buried pipeline fiber optic intrusion detection system for the suppression of nuisance events and discrimination of intrusion events. The sensor employed for both types of systems is a distributed bidirectional fiber-optic Mach-Zehnder (MZ) interferometer.
Design of the intelligent smoke alarm system based on photoelectric smoke
NASA Astrophysics Data System (ADS)
Ma, Jiangfei; Yang, Xiufang; Wang, Peipei
2017-02-01
This paper designed a kind of intelligent smoke alarm system based on photoelectric smoke detector and temperature, The system takes AT89C51 MCU as the core of hardware control and Labview as the host computer monitoring center.The sensor system acquires temperature signals and smoke signals, the MCU control A/D by Sampling and converting the output analog signals , and then the two signals will be uploaded to the host computer through the serial communication. To achieve real-time monitoring of smoke and temperature in the environment, LabVIEW monitoring platform need to hold, process, analysis and display these samping signals. The intelligent smoke alarm system is suitable for large scale shopping malls and other public places, which can greatly reduce the false alarm rate of fire, The experimental results show that the system runs well and can alarm when the setting threshold is reached,and the threshold parameters can be adjusted according to the actual conditions of the field. The system is easy to operate, simple in structure, intelligent, low cost, and with strong practical value.
Ship cabin leakage alarm based on ARM SCM
NASA Astrophysics Data System (ADS)
Qu, Liyan
2018-03-01
If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.
McGrath, Susan P; Pyke, Joshua; Taenzer, Andreas H
2017-06-01
Technology advances make it possible to consider continuous acoustic respiratory rate monitoring as an integral component of physiologic surveillance systems. This study explores technical and logistical aspects of augmenting pulse oximetry-based patient surveillance systems with continuous respiratory rate monitoring and offers some insight into the impact on patient deterioration detection that may result. Acoustic respiratory rate sensors were introduced to a general care pulse oximetry-based surveillance system with respiratory rate alarms deactivated. Simulation was used after 4324 patient days to determine appropriate alarm thresholds for respiratory rate, which were then activated. Data were collected for an additional 4382 patient days. Physiologic parameters, alarm data, sensor utilization and patient/staff feedback were collected throughout the study and analyzed. No notable technical or workflow issues were observed. Sensor utilization was 57 %, with patient refusal leading reasons for nonuse (22.7 %). With respiratory rate alarm thresholds set to 6 and 40 breaths/min., the majority of nurse pager clinical notifications were triggered by low oxygen saturation values (43 %), followed by low respiratory rate values (21 %) and low pulse rate values (13 %). Mean respiratory rate collected was 16.6 ± 3.8 breaths/min. The vast majority (82 %) of low oxygen saturation states coincided with normal respiration rates of 12-20 breaths/min. Continuous respiratory rate monitoring can be successfully added to a pulse oximetry-based surveillance system without significant technical, logistical or workflow issues and is moderately well-tolerated by patients. Respiratory rate sensor alarms did not significantly impact overall system alarm burden. Respiratory rate and oxygen saturation distributions suggest adding continuous respiratory rate monitoring to a pulse oximetry-based surveillance system may not significantly improve patient deterioration detection.
The application of machine vision in fire protection system
NASA Astrophysics Data System (ADS)
Rong, Jiang
2018-04-01
Based on the previous research, this paper introduces the theory of wavelet, collects the situation through the video system, and calculates the key information needed in the fire protection system. That is, through the algorithm to collect the information, according to the flame color characteristics and smoke characteristics were extracted, and as the characteristic information corresponding processing. Alarm system set the corresponding alarm threshold, when more than this alarm threshold, the system will alarm. This combination of flame color characteristics and smoke characteristics of the fire method not only improve the accuracy of judgment, but also improve the efficiency of judgments. Experiments show that the scheme is feasible.
Nishite, Yoshiaki; Takesawa, Shingo
2016-01-01
Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training.
Kobayashi, Leo; Gosbee, John W; Merck, Derek L
2017-07-01
(1) To develop a clinical microsystem simulation methodology for alarm fatigue research with a human factors engineering (HFE) assessment framework and (2) to explore its application to the comparative examination of different approaches to patient monitoring and provider notification. Problems with the design, implementation, and real-world use of patient monitoring systems result in alarm fatigue. A multidisciplinary team is developing an open-source tool kit to promote bedside informatics research and mitigate alarm fatigue. Simulation, HFE, and computer science experts created a novel simulation methodology to study alarm fatigue. Featuring multiple interconnected simulated patient scenarios with scripted timeline, "distractor" patient care tasks, and triggered true and false alarms, the methodology incorporated objective metrics to assess provider and system performance. Developed materials were implemented during institutional review board-approved study sessions that assessed and compared an experimental multiparametric alerting system with a standard monitor telemetry system for subject response, use characteristics, and end-user feedback. A four-patient simulation setup featuring objective metrics for participant task-related performance and response to alarms was developed along with accompanying structured HFE assessment (questionnaire and interview) for monitor systems use testing. Two pilot and four study sessions with individual nurse subjects elicited true alarm and false alarm responses (including diversion from assigned tasks) as well as nonresponses to true alarms. In-simulation observation and subject questionnaires were used to test the experimental system's approach to suppressing false alarms and alerting providers. A novel investigative methodology applied simulation and HFE techniques to replicate and study alarm fatigue in controlled settings for systems assessment and experimental research purposes.
Enhanced, Partially Redundant Emergency Notification System
NASA Technical Reports Server (NTRS)
Pounds, Clark D.
2005-01-01
The Johnson Space Center Emergency Notification System (JENS) software utilizes pre-existing computation and communication infrastructure to augment a prior variable-tone, siren-based, outdoor alarm system, in order to enhance the ability to give notice of emergencies to employees working in multiple buildings. The JENS software includes a component that implements an administrative Web site. Administrators can grant and deny access to the administrative site and to an originator Web site that enables authorized individuals to quickly compose and issue alarms. The originator site also facilitates maintenance and review of alarms already issued. A custom client/server application program enables an originator to notify every user who is logged in on a Microsoft Windows-based desktop computer by means of a pop-up message that interrupts, but does not disrupt, the user s work. Alternatively or in addition, the originator can send an alarm message to recipients on an e-mail distribution list and/or can post the notice on an internal Web site. An alarm message can consist of (1) text describing the emergency and suggesting a course of action and (2) a replica of the corresponding audible outdoor alarm.
Chair alarm for patient fall prevention based on gesture recognition and interactivity.
Knight, Heather; Lee, Jae-Kyu; Ma, Hongshen
2008-01-01
The Gesture Recognition Interactive Technology (GRiT) Chair Alarm aims to prevent patient falls from chairs and wheelchairs by recognizing the gesture of a patient attempting to stand. Patient falls are one of the greatest causes of injury in hospitals. Current chair and bed exit alarm systems are inadequate because of insufficient notification, high false-alarm rate, and long trigger delays. The GRiT chair alarm uses an array of capacitive proximity sensors and pressure sensors to create a map of the patient's sitting position, which is then processed using gesture recognition algorithms to determine when a patient is attempting to stand and to alarm the care providers. This system also uses a range of voice and light feedback to encourage the patient to remain seated and/or to make use of the system's integrated nurse-call function. This system can be seamlessly integrated into existing hospital WiFi networks to send notifications and approximate patient location through existing nurse call systems.
Network-Based Real-time Integrated Fire Detection and Alarm (FDA) System with Building Automation
NASA Astrophysics Data System (ADS)
Anwar, F.; Boby, R. I.; Rashid, M. M.; Alam, M. M.; Shaikh, Z.
2017-11-01
Fire alarm systems have become increasingly an important lifesaving technology in many aspects, such as applications to detect, monitor and control any fire hazard. A large sum of money is being spent annually to install and maintain the fire alarm systems in buildings to protect property and lives from the unexpected spread of fire. Several methods are already developed and it is improving on a daily basis to reduce the cost as well as increase quality. An integrated Fire Detection and Alarm (FDA) systems with building automation was studied, to reduce cost and improve their reliability by preventing false alarm. This work proposes an improved framework for FDA system to ensure a robust intelligent network of FDA control panels in real-time. A shortest path algorithmic was chosen for series of buildings connected by fiber optic network. The framework shares information and communicates with each fire alarm panels connected in peer to peer configuration and declare the network state using network address declaration from any building connected in network. The fiber-optic connection was proposed to reduce signal noises, thus increasing large area coverage, real-time communication and long-term safety. Based on this proposed method an experimental setup was designed and a prototype system was developed to validate the performance in practice. Also, the distributed network system was proposed to connect with an optional remote monitoring terminal panel to validate proposed network performance and ensure fire survivability where the information is sequentially transmitted. The proposed FDA system is different from traditional fire alarm and detection system in terms of topology as it manages group of buildings in an optimal and efficient manner.Introduction
Chelliah, Pandian; Murgesan, Kasinathan; Samvel, Sosamma; Chelamchala, Babu Rao; Tammana, Jayakumar; Nagarajan, Murali; Raj, Baldev
2010-07-10
Optical-fiber-based sensors have inherent advantages, such as immunity to electromagnetic interference, compared to the conventional sensors. Distributed optical fiber sensor (DOFS) systems, such as Raman and Brillouin distributed temperature sensors are used for leak detection. The inherent noise of fiber-based systems leads to occasional false alarms. In this paper, a methodology is proposed to overcome this. This uses a looped back fiber mode in DOFS and voting logic is employed to considerably reduce the false alarm rate.
Nishite, Yoshiaki; Takesawa, Shingo
2016-01-01
Background: Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. Objectives: The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. Materials and Methods: In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. Results: The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Conclusions: Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training. PMID:26981503
124. FIRE ALARM SYSTEM PANEL AT WEST SIDE OF SOUTH ...
124. FIRE ALARM SYSTEM PANEL AT WEST SIDE OF SOUTH WALL, TRANSFORMER ROOM (112), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
NASA Astrophysics Data System (ADS)
Arkhipkin, D.; Lauret, J.
2017-10-01
One of the STAR experiment’s modular Messaging Interface and Reliable Architecture framework (MIRA) integration goals is to provide seamless and automatic connections with the existing control systems. After an initial proof of concept and operation of the MIRA system as a parallel data collection system for online use and real-time monitoring, the STAR Software and Computing group is now working on the integration of Experimental Physics and Industrial Control System (EPICS) with MIRA’s interfaces. This integration goals are to allow functional interoperability and, later on, to replace the existing/legacy Detector Control System components at the service level. In this report, we describe the evolutionary integration process and, as an example, will discuss the EPICS Alarm Handler conversion. We review the complete upgrade procedure starting with the integration of EPICS-originated alarm signals propagation into MIRA, followed by the replacement of the existing operator interface based on Motif Editor and Display Manager (MEDM) with modern portable web-based Alarm Handler interface. To achieve this aim, we have built an EPICS-to-MQTT [8] bridging service, and recreated the functionality of the original Alarm Handler using low-latency web messaging technologies. The integration of EPICS alarm handling into our messaging framework allowed STAR to improve the DCS alarm awareness of existing STAR DAQ and RTS services, which use MIRA as a primary source of experiment control information.
Siebig, Sylvia; Kuhls, Silvia; Imhoff, Michael; Langgartner, Julia; Reng, Michael; Schölmerich, Jürgen; Gather, Ursula; Wrede, Christian E
2010-03-01
Monitoring of physiologic parameters in critically ill patients is currently performed by threshold alarm systems with high sensitivity but low specificity. As a consequence, a multitude of alarms are generated, leading to an impaired clinical value of these alarms due to reduced alertness of the intensive care unit (ICU) staff. To evaluate a new alarm procedure, we currently generate a database of physiologic data and clinical alarm annotations. Data collection is taking place at a 12-bed medical ICU. Patients with monitoring of at least heart rate, invasive arterial blood pressure, and oxygen saturation are included in the study. Numerical physiologic data at 1-second intervals, monitor alarms, and alarm settings are extracted from the surveillance network. Bedside video recordings are performed with network surveillance cameras. Based on the extracted data and the video recordings, alarms are clinically annotated by an experienced physician. The alarms are categorized according to their technical validity and clinical relevance by a taxonomy system that can be broadly applicable. Preliminary results showed that only 17% of the alarms were classified as relevant, and 44% were technically false. The presented system for collecting real-time bedside monitoring data in conjunction with video-assisted annotations of clinically relevant events is the first allowing the assessment of 24-hour periods and reduces the bias usually created by bedside observers in comparable studies. It constitutes the basis for the development and evaluation of "smart" alarm algorithms, which may help to reduce the number of alarms at the ICU, thereby improving patient safety. Copyright 2010 Elsevier Inc. All rights reserved.
Volumetric Security Alarm Based on a Spherical Ultrasonic Transducer Array
NASA Astrophysics Data System (ADS)
Sayin, Umut; Scaini, Davide; Arteaga, Daniel
Most of the existent alarm systems depend on physical or visual contact. The detection area is often limited depending on the type of the transducer, creating blind spots. Our proposition is a truly volumetric alarm system that can detect any movement in the intrusion area, based on monitoring the change over time of the impulse response of the room, which acts as an acoustic footprint. The device depends on an omnidirectional ultrasonic transducer array emitting sweep signals to calculate the impulse response in short intervals. Any change in the room conditions is monitored through a correlation function. The sensitivity of the alarm to different objects and different environments depends on the sweep duration, sweep bandwidth, and sweep interval. Successful detection of intrusions also depends on the size of the monitoring area and requires an adjustment of emitted ultrasound power. Strong air flow affects the performance of the alarm. A method for separating moving objects from strong air flow is devised using an adaptive thresholding on the correlation function involving a series of impulse response measurements. The alarm system can be also used for fire detection since air flow sourced from heating objects differ from random nature of the present air flow. Several measurements are made to test the integrity of the alarm in rooms sizing from 834-2080m3 with irregular geometries and various objects. The proposed system can efficiently detect intrusion whilst adequate emitting power is provided.
The design of infrared information collection circuit based on embedded technology
NASA Astrophysics Data System (ADS)
Liu, Haoting; Zhang, Yicong
2013-07-01
S3C2410 processor is a 16/32 bit RISC embedded processor which based on ARM920T core and AMNA bus, and mainly for handheld devices, and high cost, low-power applications. This design introduces a design plan of the PIR sensor system, circuit and its assembling, debugging. The Application Circuit of the passive PIR alarm uses the invisibility of the infrared radiation well into the alarm system, and in order to achieve the anti-theft alarm and security purposes. When the body goes into the range of PIR sensor detection, sensors will detect heat sources and then the sensor will output a weak signal. The Signal should be amplified, compared and delayed; finally light emitting diodes emit light, playing the role of a police alarm.
Design of embedded intelligent monitoring system based on face recognition
NASA Astrophysics Data System (ADS)
Liang, Weidong; Ding, Yan; Zhao, Liangjin; Li, Jia; Hu, Xuemei
2017-01-01
In this paper, a new embedded intelligent monitoring system based on face recognition is proposed. The system uses Pi Raspberry as the central processor. A sensors group has been designed with Zigbee module in order to assist the system to work better and the two alarm modes have been proposed using the Internet and 3G modem. The experimental results show that the system can work under various light intensities to recognize human face and send alarm information in real time.
Smart container UWB sensor system for situational awareness of intrusion alarms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romero, Carlos E.; Haugen, Peter C.; Zumstein, James M.
An in-container monitoring sensor system is based on an UWB radar intrusion detector positioned in a container and having a range gate set to the farthest wall of the container from the detector. Multipath reflections within the container make every point on or in the container appear to be at the range gate, allowing intrusion detection anywhere in the container. The system also includes other sensors to provide false alarm discrimination, and may include other sensors to monitor other parameters, e.g. radiation. The sensor system also includes a control subsystem for controlling system operation. Communications and information extraction capability maymore » also be included. A method of detecting intrusion into a container uses UWB radar, and may also include false alarm discrimination. A secure container has an UWB based monitoring system« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasemir, Kay; Hartman, Steven M
2009-01-01
A new alarm system toolkit has been implemented at SNS. The toolkit handles the Central Control Room (CCR) 'annunciator', or audio alarms. For the new alarm system to be effective, the alarms must be meaningful and properly configured. Along with the implementation of the new alarm toolkit, a thorough documentation and rationalization of the alarm configuration is taking place. Requirements and maintenance of a robust alarm configuration have been gathered from system and operations experts. In this paper we present our practical experience with the vacuum system alarm handling configuration of the alarm toolkit.
NASA Astrophysics Data System (ADS)
Mu, Kai
2017-02-01
The established “Map World” on the National Geographic Information Public Service Platform offers free access to many geographic information in the Core Area of the Silk Road Economic Belt. Considering the special security situation and severe splittism and anti-splittism struggles in the Core Area of the Silk Road Economic Belt, a set of moving target positioning and alarming platform based on J2EE platform and B/S structure was designed and realized by combining the “Map World” data and global navigation satellite system. This platform solves various problems, such as effective combination of Global Navigation Satellite System (GNSS) and “Map World” resources, moving target alarming setting, inquiry of historical routes, system management, etc.
46 CFR 113.43-3 - Alarm system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...
46 CFR 113.43-3 - Alarm system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...
46 CFR 113.43-3 - Alarm system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...
Building Security. Honeywell Planning Guide.
ERIC Educational Resources Information Center
Honeywell, Inc., Minneapolis, Minn.
A general discussion of building detection and alarm systems to provide security against burglary and vandalism is provided by a manufacturer of automated monitoring and control systems. Security systems are identified as--(1) local alarm system, (2) central station alarm system, (3) proprietary alarm system, and (4) direct connect alarm system..…
Solvoll, Terje; Arntsen, Harald; Hartvigsen, Gunnar
2017-01-01
Surveys and research show that mobile communication systems in hospital settings are old and cause frequent interruptions. In the quest to remedy this, an Android based communication system called CallMeSmart tries to encapsulate most of the frequent communication into one hand held device focusing on reducing interruptions and at the same time make the workday easier for healthcare workers. The objective of CallMeSmart is to use context-awareness techniques to automatically monitor the availability of physicians' and nurses', and use this information to prevent or route phone calls, text messages, pages and alarms that would otherwise compromise patient care. In this paper, we present the results from interviewing nurses on alarm fatigue and their expectations regarding context-aware alarm handling using CallMeSmart.
Design of indoor temperature and humidity detection system based on single chip microcomputer
NASA Astrophysics Data System (ADS)
Fu, Xiuwei; Fu, Li; Ma, Tianhui
2018-03-01
The indoor temperature and humidity detection system based on STC15F2K60S2 is designed in this paper. The temperature and humidity sensor DHT22 to monitor the indoor temperature and humidity are used, and the temperature and humidity data to the user's handheld device are wirelessly transmitted, when the temperature reaches or exceeds the user set the temperature alarm value, and the system sound and light alarm, to remind the user.
Multiple-Parameter, Low-False-Alarm Fire-Detection Systems
NASA Technical Reports Server (NTRS)
Hunter, Gary W.; Greensburg, Paul; McKnight, Robert; Xu, Jennifer C.; Liu, C. C.; Dutta, Prabir; Makel, Darby; Blake, D.; Sue-Antillio, Jill
2007-01-01
Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.
Dynamic alarm response procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, J.; Gordon, P.; Fitch, K.
2006-07-01
The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache{sup R}, IIS{sup R}, TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphicsmore » (SVG), such as Netscape{sup R}, Microsoft Internet Explorer{sup R}, Mozilla Firefox{sup R}, Opera{sup R}, and others. (authors)« less
Cowen, R.G.
1959-09-29
A description is given of electric protective systems and burglar alarm systems of the capacitance type in which the approach of an intruder at a place to be protected varies the capacitance in an electric circuit and the change is thereafter communicated to a remote point to actuate an alarm. According to the invention, an astable transitor multi-vibrator has the amplitude at its output voltage controlled by a change in the sensing capacitance. The sensing capacitance is effectively connected between collector and base of one stage of the multivibrator circuit through the detector-to-monitor line. The output of the detector is a small d-c voltage across the detector-to-monitor line. This d- c voltage is amplified and monitored at the other end of the line, where an appropriate alarm is actuated if a sudden change in the voltage occurs. The present system has a high degree of sensitivity and is very difficult to defeat by known techniques.
Bonneville Power Administration Communication Alarm Processor expert system:
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goeltz, R.; Purucker, S.; Tonn, B.
This report describes the Communications Alarm Processor (CAP), a prototype expert system developed for the Bonneville Power Administration by Oak Ridge National Laboratory. The system is designed to receive and diagnose alarms from Bonneville's Microwave Communications System (MCS). The prototype encompasses one of seven branches of the communications network and a subset of alarm systems and alarm types from each system. The expert system employs a backward chaining approach to diagnosing alarms. Alarms are fed into the expert system directly from the communication system via RS232 ports and sophisticated alarm filtering and mailbox software. Alarm diagnoses are presented to operatorsmore » for their review and concurrence before the diagnoses are archived. Statistical software is incorporated to allow analysis of archived data for report generation and maintenance studies. The delivered system resides on a Digital Equipment Corporation VAX 3200 workstation and utilizes Nexpert Object and SAS for the expert system and statistical analysis, respectively. 11 refs., 23 figs., 7 tabs.« less
[Research on early fire detection with CO-CO2 FTIR-spectroscopy].
Du, Jian-hua; Zhang, Ren-cheng; Huang, Xiang-ying; Gong, Xue; Zhang, Xiao-hua
2007-05-01
A new fire detection method is put forward based on the theory of FTIR spectroscopy through analyzing all kinds of detection methods, in which CO and CO2 are chosen as early fire detection objects, and an early fire experiment system has been set up. The concentration characters of CO and CO2 were obtained through early fire experiments including real alarm sources and nuisance alarm sources. In real alarm sources there are abundant CO and CO2 which change regularly. In nuisance alarm sources there is almost no CO. So it's feasible to reduce the false alarms and increase the sensitivity of early fire detectors through analyzing the concentration characters of CO and CO2.
Development and experimental evaluation of an alarm concept for an integrated surgical workstation.
Zeißig, Eva-Maria; Janß, Armin; Dell'Anna-Pudlik, Jasmin; Ziefle, Martina; Radermacher, Klaus
2016-04-01
Alarm conditions of the technical equipment in operating rooms represent a prevalent cause for interruptions of surgeons and scrub nurses, resulting in an increase of workload and potential reduction of patient safety. In this work, an alarm concept for an integrated operating room system based on open communication standards is developed and tested. In a laboratory experiment, the reactions of surgeons were analysed, comparing the displaying of alarms on an integrated workstation and on single devices: disruptive effects of alarm handling on primary task (ratings of perceived distraction, resumption lag, deterioration of speed, accuracy, and prospective memory), efficiency and effectiveness of identification of alarms, as well as perceived workload were included. The identification of the alarm cause is significantly more efficient and effective with the integrated alarm concept. Moreover, a slightly lower deterioration of performance of the primary task due to the interruption of alarm handling was observed. Displaying alarms on an integrated workstation supports alarm handling and consequently reduces disruptive effects on the primary task. The findings show that even small changes can reduce workload in a complex work environment like the operating room, resulting in improved patient safety.
Yang, Kun; Perez, Manuela; Hossu, Gabriela; Hubert, Nicolas; Perrenot, Cyril; Hubert, Jacques
2017-01-01
In robotic surgery, the professional ergonomic habit of using an armrest reduces operator fatigue and increases the precision of motion. We designed and validated a pressure surveillance system (PSS) based on force sensors to investigate armrest use. The objective was to evaluate whether adding an alarm to the PSS system could shorten ergonomic training and improve performance. Twenty robot and simulator-naïve participants were recruited and randomized in two groups (A and B). The PSS was installed on a robotic simulator, the dV-Trainer, to detect contact with the armrest. The Group A members completed three tasks on the dV-Trainer without the alarm, making 15 attempts at each task. The Group B members practiced the first two tasks with the alarm and then completed the final tasks without the alarm. The simulator provided an overall score reflecting the trainees' performance. We used the new concept of an "armrest load" score to describe the ergonomic habit of using the armrest. Group B had a significantly higher performance score (p < 0.001) and armrest load score (p < 0.001) than Group A from the fifth attempt of the first task to the end of the experiment. Based on the conditioned reflex effect, the alarm associated with the PSS rectified ergonomic errors and accelerated professional ergonomic habit acquisition. The combination of the PSS and alarm is effective in significantly shortening the learning curve in the robotic training process.
A novel algorithm for reducing false arrhythmia alarms in intensive care units.
Srivastava, Chandan; Sharma, Sonal; Jalali, Ali
2016-08-01
Alarm fatigue in intensive care units (ICU) is one of the top healthcare issues in the US. False alarms in ICU will decrease the quality of care and staff response time over the alarms. Normally, false alarm will cause desensitization of the clinical staff which leads to warnings and misleading, if the triggered alarm is true. In this study, we have proposed a multi-model ensemble approach to reduce the false alarm rate in monitoring systems. We have used 750 patient records from PhysioNet database. At First arrhythmia based features from electrocardiogram (ECG), arterial blood pressure (ABP) and photoplethysmogram (PPG) features were extracted from the records. Next, the dataset has been separated into two subsets on the basis of available features information. The first dataset (DS1) is the combination of ECG physiological, ABP and PPG features. Their correlation coefficient and p-values criteria have been applied for relevant alarm-wise feature-set selection, and random forest classifier was used for model development and validation. The threshold based approach was used on second dataset (DS2) which is the combination of arrhythmia, ABP and PPG features. The developed ensemble model is able to achieve sensitivity 83.33-100 % (average 95.56 %) being true alarms and suppress false alarms rate 66.67-89% (average 77.25%). The predictability of classifier shows the advantage to deal with unbalanced set of information, therefore overall model performance has reached to 83.96% accuracy.
Improved security monitoring method for network bordary
NASA Astrophysics Data System (ADS)
Gao, Liting; Wang, Lixia; Wang, Zhenyan; Qi, Aihua
2013-03-01
This paper proposes a network bordary security monitoring system based on PKI. The design uses multiple safe technologies, analysis deeply the association between network data flow and system log, it can detect the intrusion activities and position invasion source accurately in time. The experiment result shows that it can reduce the rate of false alarm or missing alarm of the security incident effectively.
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground alarm systems. 57.4360 Section 57...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground alarm systems. 57.4360 Section 57...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground alarm systems. 57.4360 Section 57...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground alarm systems. 57.4360 Section 57...
NASA Astrophysics Data System (ADS)
Hanson, Jeffrey A.; McLaughlin, Keith L.; Sereno, Thomas J.
2011-06-01
We have developed a flexible, target-driven, multi-modal, physics-based fusion architecture that efficiently searches sensor detections for targets and rejects clutter while controlling the combinatoric problems that commonly arise in datadriven fusion systems. The informational constraints imposed by long lifetime requirements make systems vulnerable to false alarms. We demonstrate that our data fusion system significantly reduces false alarms while maintaining high sensitivity to threats. In addition, mission goals can vary substantially in terms of targets-of-interest, required characterization, acceptable latency, and false alarm rates. Our fusion architecture provides the flexibility to match these trade-offs with mission requirements unlike many conventional systems that require significant modifications for each new mission. We illustrate our data fusion performance with case studies that span many of the potential mission scenarios including border surveillance, base security, and infrastructure protection. In these studies, we deployed multi-modal sensor nodes - including geophones, magnetometers, accelerometers and PIR sensors - with low-power processing algorithms and low-bandwidth wireless mesh networking to create networks capable of multi-year operation. The results show our data fusion architecture maintains high sensitivities while suppressing most false alarms for a variety of environments and targets.
Dual sensitivity mode system for monitoring processes and sensors
Wilks, Alan D.; Wegerich, Stephan W.; Gross, Kenneth C.
2000-01-01
A method and system for analyzing a source of data. The system and method involves initially training a system using a selected data signal, calculating at least two levels of sensitivity using a pattern recognition methodology, activating a first mode of alarm sensitivity to monitor the data source, activating a second mode of alarm sensitivity to monitor the data source and generating a first alarm signal upon the first mode of sensitivity detecting an alarm condition and a second alarm signal upon the second mode of sensitivity detecting an associated alarm condition. The first alarm condition and second alarm condition can be acted upon by an operator and/or analyzed by a specialist or computer program.
Judging the urgency of non-verbal auditory alarms: a case study.
Arrabito, G Robert; Mondor, Todd; Kent, Kimberley
2004-06-22
When designed correctly, non-verbal auditory alarms can convey different levels of urgency to the aircrew, and thereby permit the operator to establish the appropriate level of priority to address the alarmed condition. The conveyed level of urgency of five non-verbal auditory alarms presently used in the Canadian Forces CH-146 Griffon helicopter was investigated. Pilots of the CH-146 Griffon helicopter and non-pilots rated the perceived urgency of the signals using a rating scale. The pilots also ranked the urgency of the alarms in a post-experiment questionnaire to reflect their assessment of the actual situation that triggers the alarms. The results of this investigation revealed that participants' ratings of perceived urgency appear to be based on the acoustic properties of the alarms which are known to affect the listener's perceived level of urgency. Although for 28% of the pilots the mapping of perceived urgency to the urgency of their perception of the triggering situation was statistically significant for three of the five alarms, the overall data suggest that the triggering situations are not adequately conveyed by the acoustic parameters inherent in the alarms. The pilots' judgement of the triggering situation was intended as a means of evaluating the reliability of the alerting system. These data will subsequently be discussed with respect to proposed enhancements in alerting systems as it relates to addressing the problem of phase of flight. These results call for more serious consideration of incorporating situational awareness in the design and assignment of auditory alarms in aircraft.
Optimal Sensor Location Design for Reliable Fault Detection in Presence of False Alarms
Yang, Fan; Xiao, Deyun; Shah, Sirish L.
2009-01-01
To improve fault detection reliability, sensor location should be designed according to an optimization criterion with constraints imposed by issues of detectability and identifiability. Reliability requires the minimization of undetectability and false alarm probability due to random factors on sensor readings, which is not only related with sensor readings but also affected by fault propagation. This paper introduces the reliability criteria expression based on the missed/false alarm probability of each sensor and system topology or connectivity derived from the directed graph. The algorithm for the optimization problem is presented as a heuristic procedure. Finally, a boiler system is illustrated using the proposed method. PMID:22291524
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample... unit, fire detectors, smoke detectors, and audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. (c) Manual fire alarm systems. For the purpose of this...
46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...
46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...
Early warning, warning or alarm systems for natural hazards? A generic classification.
NASA Astrophysics Data System (ADS)
Sättele, Martina; Bründl, Michael; Straub, Daniel
2013-04-01
Early warning, warning and alarm systems have gained popularity in recent years as cost-efficient measures for dangerous natural hazard processes such as floods, storms, rock and snow avalanches, debris flows, rock and ice falls, landslides, flash floods, glacier lake outburst floods, forest fires and even earthquakes. These systems can generate information before an event causes loss of property and life. In this way, they mainly mitigate the overall risk by reducing the presence probability of endangered objects. These systems are typically prototypes tailored to specific project needs. Despite their importance there is no recognised system classification. This contribution classifies warning and alarm systems into three classes: i) threshold systems, ii) expert systems and iii) model-based expert systems. The result is a generic classification, which takes the characteristics of the natural hazard process itself and the related monitoring possibilities into account. The choice of the monitoring parameters directly determines the system's lead time. The classification of 52 active systems moreover revealed typical system characteristics for each system class. i) Threshold systems monitor dynamic process parameters of ongoing events (e.g. water level of a debris flow) and incorporate minor lead times. They have a local geographical coverage and a predefined threshold determines if an alarm is automatically activated to warn endangered objects, authorities and system operators. ii) Expert systems monitor direct changes in the variable disposition (e.g crack opening before a rock avalanche) or trigger events (e.g. heavy rain) at a local scale before the main event starts and thus offer extended lead times. The final alarm decision incorporates human, model and organisational related factors. iii) Model-based expert systems monitor indirect changes in the variable disposition (e.g. snow temperature, height or solar radiation that influence the occurrence probability of snow avalanches) or trigger events (e.g. heavy snow fall) to predict spontaneous hazard events in advance. They encompass regional or national measuring networks and satisfy additional demands such as the standardisation of the measuring stations. The developed classification and the characteristics, which were revealed for each class, yield a valuable input to quantifying the reliability of warning and alarm systems. Importantly, this will facilitate to compare them with well-established standard mitigation measures such as dams, nets and galleries within an integrated risk management approach.
Bedubourg, Gabriel; Abat, Cédric; Colson, Philippe; Rolain, Jean Marc; Chaudet, Hervé; Fournier, Pierre Edouard; Raoult, Didier; Deparis, Xavier
2017-01-01
We describe the implementation of an automated infectious disease surveillance system that uses data collected from 210 microbiologic laboratories throughout the Provence-Alpes-Côte d’Azur region in France. Each week, these facilities report bacterial species that have been isolated from patients in their area. An alarm is triggered whenever the case count for a bacterial species infection exceeds 2 SDs of the historical mean for that species at the participating laboratory. At its inception in July 2013, the system monitored 611 bacterial species. During July 1, 2013–March 20, 2016, weekly analyses of incoming surveillance data generated 34 alarms signaling possible infectious disease outbreaks; after investigation, 14 (41%) of these alarms resulted in health alerts declared by the regional health authority. We are currently improving the system by developing an Internet-based surveillance platform and extending our surveillance to include more laboratories in the region. PMID:28322712
2009-09-01
Forecasts ECS East China Sea ESRL Earth Systems Research Laboratory FA False alarm FARate False alarm rate xviii GDEM Generalized Digital...uses a LTM based, global ocean climatology database called Generalized Digital Environment Model ( GDEM ), in tactical decision aid (TDA) software, such...environment for USW planning. GDEM climatology is derived using temperature and salinity profiles from the Modular Ocean Data Assimilation System
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
46 CFR 113.25-12 - Alarm signals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...
NASA Astrophysics Data System (ADS)
Cui, Yiqian; Shi, Junyou; Wang, Zili
2017-11-01
Built-in tests (BITs) are widely used in mechanical systems to perform state identification, whereas the BIT false and missed alarms cause trouble to the operators or beneficiaries to make correct judgments. Artificial neural networks (ANN) are previously used for false and missed alarms identification, which has the features such as self-organizing and self-study. However, these ANN models generally do not incorporate the temporal effect of the bottom-level threshold comparison outputs and the historical temporal features are not fully considered. To improve the situation, this paper proposes a new integrated BIT design methodology by incorporating a novel type of dynamic neural networks (DNN) model. The new DNN model is termed as Forward IIR & Recurrent FIR DNN (FIRF-DNN), where its component neurons, network structures, and input/output relationships are discussed. The condition monitoring false and missed alarms reduction implementation scheme based on FIRF-DNN model is also illustrated, which is composed of three stages including model training, false and missed alarms detection, and false and missed alarms suppression. Finally, the proposed methodology is demonstrated in the application study and the experimental results are analyzed.
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
46 CFR 113.20-1 - Sprinkler alarm system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...
Evaluation of a radar-based proximity warning system for off-highway dump trucks.
Ruff, Todd
2006-01-01
A radar-based proximity warning system was evaluated by researchers at the Spokane Research Laboratory of the National Institute for Occupational Safety and Health to determine if the system would be effective in detecting objects in the blind spots of an off-highway dump truck. An average of five fatalities occur each year in surface mines as a result of an equipment operator not being aware of a smaller vehicle, person or change in terrain near the equipment. Sensor technology that can detect such obstacles and that also is designed for surface mining applications is rare. Researchers worked closely with the radar system manufacturer to test and modify the system on large, off-highway dump trucks at a surface mine over a period of 2 years. The final system was thoroughly evaluated by recording video images from a camera on the rear of the truck and by recording all alarms from the rear-mounted radar. Data show that the system reliably detected small vehicles, berms, people and other equipment. However, alarms from objects that posed no immediate danger were common, supporting the assertion that sensor-based systems for proximity warning should be used in combination with other devices, such as cameras, that would allow the operator to check the source of any alarm.
Clinical evaluation of a noninvasive alarm system for nocturnal hypoglycemia.
Skladnev, Victor N; Ghevondian, Nejhdeh; Tarnavskii, Stanislav; Paramalingam, Nirubasini; Jones, Timothy W
2010-01-01
The aim of this study was to evaluate the performance of a prototype noninvasive alarm system (HypoMon) for the detection of nocturnal hypoglycemia. A prospective cohort study evaluated an alarm system that included a sensor belt, a radio frequency transmitter for chest belt signals, and a receiver. The receiver incorporated integrated "real-time" algorithms designed to recognize hypoglycemia "signatures" in the physiological parameters monitored by the sensor belt. Fifty-two children and young adults with type 1 diabetes mellitus (T1DM) participated in this blinded, prospective, in-clinic, overnight study. Participants had a mean age of 16 years (standard deviation 2.1, range 12-20 years) and were asked to follow their normal meal and insulin routines for the day of the study. Participants had physiological parameters monitored overnight by a single HypoMon system. Their BG levels were also monitored overnight at regular intervals via an intravenous cannula and read on two independent Yellow Springs Instruments analyzers. Hypoglycemia was not induced by any manipulations of diabetes management, rather the subjects were monitored overnight for "natural" occurrences of hypoglycemia. Performance analyses included comparing HypoMon system alarm times with allowed time windows associated with each hypoglycemic event. The primary recognition algorithm in the prototype alarm system performed at a level consistent with expectations based on prior user surveys. The HypoMon system correctly recognized 8 out of the 11 naturally occurring overnight hypoglycemic events and falsely alarmed on 13 out of the remaining 41 normal nights [sensitivity 73% (8/11), specificity 68% (28/41), positive predictive value 38%,negative predictive value 90%]. The prototype HypoMon shows potential as an adjunct method for noninvasive overnight monitoring for hypoglycemia events in young people with T1DM. 2010 Diabetes Technology Society.
Evaluated community fire safety interventions in the United States: a review of current literature.
Ta, Van M; Frattaroli, Shannon; Bergen, Gwendolyn; Gielen, Andrea Carlson
2006-06-01
The purpose of the study was to assess the state of fire prevention research, provide an updated synthesis of evaluated fire prevention programs, and discuss the role of fire fighters and data systems in prevention efforts. The review included all evaluations of U.S. based fire prevention interventions published between January 1998 and September 2004 and any earlier articles about U.S. fire prevention interventions not included in two prior review articles. We retrieved information from each identified study including evaluation findings, involvement of fire service personnel and use of existing data systems. We identified twelve articles: seven reported on smoke alarm interventions, three on multi-faceted programs, and two other programs. Five programs involved fire service personnel in the design, implementation, and/or evaluation, and three used existing data systems. Studies reviewed suggest that canvassing and smoke alarm installations are the most effective means of distributing alarms and increasing the functional status of distributed alarms. The functionality of smoke alarms, an issue noted in earlier reviews, remains a problem. Programs involving partnerships with fire departments have indicated success in preventing fires and deaths, improving smoke alarm ownership and functional status, and improving children's fire safety knowledge. Using existing data systems to target and to evaluate interventions was effective. In the years since prior reviews, some improvements in the rigor of evaluation designs have been made, but there is still a need for high quality evaluations that will inform fire injury prevention efforts.
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...
Alarm systems detect volcanic tremor and earthquake swarms during Redoubt eruption, 2009
NASA Astrophysics Data System (ADS)
Thompson, G.; West, M. E.
2009-12-01
We ran two alarm algorithms on real-time data from Redoubt volcano during the 2009 crisis. The first algorithm was designed to detect escalations in continuous seismicity (tremor). This is implemented within an application called IceWeb which computes reduced displacement, and produces plots of reduced displacement and spectrograms linked to the Alaska Volcano Observatory internal webpage every 10 minutes. Reduced displacement is a measure of the amplitude of volcanic tremor, and is computed by applying a geometrical spreading correction to a displacement seismogram. When the reduced displacement at multiple stations exceeds pre-defined thresholds and there has been a factor of 3 increase in reduced displacement over the previous hour, a tremor alarm is declared. The second algorithm was to designed to detect earthquake swarms. The mean and median event rates are computed every 5 minutes based on the last hour of data from a real-time event catalog. By comparing these with thresholds, three swarm alarm conditions can be declared: a new swarm, an escalation in a swarm, and the end of a swarm. The end of swarm alarm is important as it may mark a transition from swarm to continuous tremor. Alarms from both systems were dispatched using a generic alarm management system which implements a call-down list, allowing observatory scientists to be called in sequence until someone acknowledged the alarm via a confirmation web page. The results of this simple approach are encouraging. The tremor alarm algorithm detected 26 of the 27 explosive eruptions that occurred from 23 March - 4 April. The swarm alarm algorithm detected all five of the main volcanic earthquake swarm episodes which occurred during the Redoubt crisis on 26-27 February, 21-23 March, 26 March, 2-4 April and 3-7 May. The end-of-swarm alarms on 23 March and 4 April were particularly helpful as they were caused by transitions from swarm to tremor shortly preceding explosive eruptions; transitions which were detected much earlier by the swarm algorithm than they were by the tremor algorithm.
Spering, C; Roessler, M; Kurlemann, T; Dresing, K; Stürmer, K M; Lehmann, W; Sehmisch, S
2017-12-12
The treatment of severely injured patients in the trauma resuscitation unit (TRU) requires an interdisciplinary and highly professional trauma team approach. The complete team needs to be waiting for the patient in the TRU on arrival. Treating severely injured patients in the TRU, the trauma team connects the initial preclinical emergency stabilization with the subsequent sophisticated treatment. Thus, the trauma team depends on concise information from the emergency personnel at the scene to provide its leader with further information as well as an accurate alarm including all departments necessary to stabilize the patient in the TRU. Aiming at an accurate and most efficient trauma team alarm, this study was designed to provide and analyze an alarm system which mobilizes the trauma team in a stepwise fashion depending on the pattern of injuries and the threat to life. The trauma team alarm system was analyzed in a prospective data acquisition at a level I trauma center over a period of 12 months. Evaluation followed the acquisition phase and provided comparison to the status prior to the establishment of the alarm system. All items underwent statistical testing using t‑tests (p < 0.05). The data of 775 TRU patients showed a significant reduction of false information on the patients status prior to arrival. It also showed an increase in punctual arrival in the TRU of the emergency teams. False alarms were significantly reduced (from 11.9% to 2.7%, p > 0.01). The duration from arrival of the patient in the TRU to the initial multislice computed tomography (CT) scan was reduced by 6 min while the total period of treatment in the TRU was reduced by 17 min. After the alarm system to gradually mobilize the trauma team was put into action, team members left the TRU if unneeded prior to finishing the initial treatment in only 4% of the cases. The patient fatality rate was 8.8% (injury severity score, ISS = 23 points) after establishment of the alarm system compared to 12.9% (ISS = 25 points) before. The implementation of an accurate and patient status-based alarm system to mobilize the trauma team can improve the quality of treatment while the duration of treatment of the severely injured patients in the TRU can be decreased. It also provides a most efficient mobilization of personnel resources while sustaining patient safety.
Tarriela, Albert Fajardo; Gomez, Tiffany Michelle; Reed, Charles Calhoun; Rapp, Kami Marie
2015-01-01
Background Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step toward this requirement is identifying ICU nurses’ perceptions and common clinical practices toward clinical alarms, where little information is available. Objective Our aim was to determine perceptions and practices of transplant/cardiac ICU (TCICU) nurses toward clinical alarms and benchmark the results against the 2011 Healthcare Technology Foundation’s (HTF) Clinical Alarms Committee Survey. Methods A quality improvement project was conducted on a 20-bed TCICU with 39 full- and part-time nurses. Nurses were surveyed about their perceptions and attitudes toward and practices on clinical alarms using an adapted HTF clinical alarms survey. Results were compared to the 2011 HTF data. Correlations among variables were examined. Results All TCICU nurses provided usable responses (N=39, 100%). Almost all nurses (95%-98%) believed that false alarms are frequent, disrupt care, and reduce trust in alarm systems, causing nurses to inappropriately disable them. Unlike the 2011 HTF clinical alarms survey results, a significantly higher percentage of our TCICU nurses believed that existing devices are complex, questioned the ability and adequacy of the new monitoring systems to solve alarm management issues, pointed to the lack of prompt response to alarms, and indicated the lack of clinical policy on alarm management (P<.01). Major themes in the narrative data focused on nurses’ frustration related to the excessive number of alarms and poor usability of the cardiac monitors. A lack of standardized approaches exists in changing patients’ electrodes and individualizing parameters. Around 60% of nurses indicated they received insufficient training on bedside and central cardiac monitors. A correlation also showed the need for training on cardiac monitors, specifically for older nurses (P=.01). Conclusions False and non-actionable alarms continue to desensitize TCICU nurses, perhaps resulting in missing fatal alarms. Nurses’ attitudes and practices related to clinical alarms are key elements for designing contextually sensitive quality initiatives to fight alarm fatigue. Alarm management in ICUs is a multidimensional complex process involving usability of monitoring devices, and unit, clinicians, training, and policy-related factors. This indicates the need for a multi-method approach to decrease alarm fatigue and improve alarm systems safety. PMID:27025940
NASA Astrophysics Data System (ADS)
Molina-Jimenez, Teresa; Caballero-Aroca, Jose; Simón-Martín, Santiago; Hervás-Juan, Juan; García-Martínez, Jose-David; Pérez-Picazo, Emilio; Dolz-García, Ramón; Pons-Vila, Alejandro; Quintana-Rumbau, Salvador; Valiente Pardo, Jose Antonio; Estrela, Maria José; Pastor-Guzmán, Francisco
2005-09-01
We present results of a R&D project aimed to produce an environmental surveillance system that, working in wild areas, allows for a real-time observation and control of some ambient factors that could produce a natural disaster. The main objective of the project is the development of an open platform capable to work with several kinds of sensors, in order to adapt itself to the needs of each situation. The detection of environmental risks and management of this data to give a real-time response is the overall objective of the project. The main parts of the system are: 1.- Detection system: capable to perform real-time data and image communication, fully autonomous and designed to consider the environmental conditions. 2.- Alarm management headquaters: reception on real-time of data from the detector network. All the data is analysed to enable a decision about whether there is or not an alarm situation. 3.- Mobile alarm-reception system: portable system for reception of the alarm signal from the headquaters. The project was financed by the Science and Technology Ministry, National Research and Development Programme (TIC2000-0366-P4, 2001-2004).
105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
KINKEL, C.C.
1999-12-14
This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less
Study of Threat Scenario Reconstruction based on Multiple Correlation
NASA Astrophysics Data System (ADS)
Yuan, Xuejun; Du, Jing; Qin, Futong; Zhou, Yunyan
2017-10-01
The emergence of intrusion detection technology has solved many network attack problems, ensuring the safety of computer systems. However, because of the isolated output alarm information, large amount of data, and mixed events, it is difficult for the managers to understand the deep logic relationship between the alarm information, thus they cannot deduce the attacker’s true intentions. This paper presents a method of online threat scene reconstruction to handle the alarm information, which reconstructs of the threat scene. For testing, the standard data set is used.
40 CFR 267.34 - When must personnel have access to communication equipment or an alarm system?
Code of Federal Regulations, 2010 CFR
2010-07-01
... to an internal alarm or emergency communication device, either directly or through visual or voice... communication equipment or an alarm system? 267.34 Section 267.34 Protection of Environment ENVIRONMENTAL... have access to communication equipment or an alarm system? (a) Whenever hazardous waste is being poured...
Rapidly quantifying the relative distention of a human bladder
NASA Technical Reports Server (NTRS)
Companion, John A. (Inventor); Heyman, Joseph S. (Inventor); Mineo, Beth A. (Inventor); Cavalier, Albert R. (Inventor); Blalock, Travis N. (Inventor)
1991-01-01
A device and method was developed to rapidly quantify the relative distention of the bladder of a human subject. An ultrasonic transducer is positioned on the human subject near the bladder. A microprocessor controlled pulser excites the transducer by sending an acoustic wave into the human subject. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer where it is received, amplified, and processed by the receiver. The resulting signal is digitized by an analog to digital converter, controlled by the microprocessor again, and is stored in data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy. Based on programmed scientific measurements and the human subject's past history as contained in program memory, the microprocessor sends out a signal to turn on any or all of the available alarms. The alarm system includes and audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.
Substation alarm multiplexing system (SAMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
ElBadaly, H.; Gaughan, J.; Ward, G.
1996-03-01
This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
30 CFR 57.4360 - Underground alarm systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4360 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm...
NASA Astrophysics Data System (ADS)
Moradi, Saed; Moallem, Payman; Sabahi, Mohamad Farzan
2018-03-01
False alarm rate and detection rate are still two contradictory metrics for infrared small target detection in an infrared search and track system (IRST), despite the development of new detection algorithms. In certain circumstances, not detecting true targets is more tolerable than detecting false items as true targets. Hence, considering background clutter and detector noise as the sources of the false alarm in an IRST system, in this paper, a false alarm aware methodology is presented to reduce false alarm rate while the detection rate remains undegraded. To this end, advantages and disadvantages of each detection algorithm are investigated and the sources of the false alarms are determined. Two target detection algorithms having independent false alarm sources are chosen in a way that the disadvantages of the one algorithm can be compensated by the advantages of the other one. In this work, multi-scale average absolute gray difference (AAGD) and Laplacian of point spread function (LoPSF) are utilized as the cornerstones of the desired algorithm of the proposed methodology. After presenting a conceptual model for the desired algorithm, it is implemented through the most straightforward mechanism. The desired algorithm effectively suppresses background clutter and eliminates detector noise. Also, since the input images are processed through just four different scales, the desired algorithm has good capability for real-time implementation. Simulation results in term of signal to clutter ratio and background suppression factor on real and simulated images prove the effectiveness and the performance of the proposed methodology. Since the desired algorithm was developed based on independent false alarm sources, our proposed methodology is expandable to any pair of detection algorithms which have different false alarm sources.
46 CFR 153.409 - High level alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false High level alarms. 153.409 Section 153.409 Shipping... Systems § 153.409 High level alarms. When Table 1 refers to this section or requires a cargo to have a closed gauging system, the cargo's containment system must have a high level alarm: (a) That gives an...
Reducing SCADA System Nuisance Alarms in the Water Industry in Northern Ireland.
O'Donoghue, Nigel; Phillips, Debra H; Nicell, Ciaran
2015-08-01
The advancement of telemetry control for the water industry has increased the difficulty of managing large volumes of nuisance alarms (i.e., alarms that do not require a response). The aim of this study was to identify and reduce the number of nuisance alarms that occur for Northern Ireland (NI) Water by carrying out alarm duration analysis to determine the appropriate length of persistence (an advanced alarm management tool) that could be applied. All data were extracted from TelemWeb (NI Water's telemetry monitoring system) and analyzed in Excel. Over a 6-week period, an average of 40 000 alarms occurred per week. The alarm duration analysis, which has never been implemented before by NI Water, found that an average of 57% of NI Water alarms had a duration of <5 minutes. Applying 5-minute persistence, therefore, could prevent an average 26 816 nuisance alarms per week. Most of these alarms were from wastewater assets.
77 FR 551 - Privacy Act of 1974; Amended System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-05
... Act system of records entitled ``Treasury/BEP .027--Access Control and Alarm Monitoring Systems (ACAMS... .027--Access Control and Alarm Monitoring Systems (ACAMS).'' BEP proposes to amend that system of... records entitled ``BEP .027--Access Control and Alarm Monitoring Systems (ACAMS),'' as follows: Treasury...
Alarm Fatigue: Use of an Evidence-Based Alarm Management Strategy.
Turmell, Jacob W; Coke, Lola; Catinella, Rachel; Hosford, Tracy; Majeski, Amy
The purpose of this article is to describe the impact of an evidence-based alarm management strategy on patient safety. An alarm management program reduced alarms up to 30%. Evaluation of patients on continuous cardiac monitoring showed a 3.5% decrease in census. This alarm management strategy has the potential to save $136 500 and 841 hours of registered nurses' time per year. No patient harm occurred during the 2-year project.
Visual display and alarm system for wind tunnel static and dynamic loads
NASA Technical Reports Server (NTRS)
Hanly, Richard D.; Fogarty, James T.
1987-01-01
A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanisms, or tunnel shutdown.
Visual display and alarm system for wind tunnel static and dynamic loads
NASA Technical Reports Server (NTRS)
Hanly, Richard D.; Fogarty, James T.
1987-01-01
A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanism, or tunnel shutdown.
Controlled trial of standard pad and bell alarm against mini alarm for nocturnal enuresis.
Fordham, K E; Meadow, S R
1989-01-01
Fifty six children aged from 6-16 years who wet their beds at night were entered into a controlled trial of two alarm devices: a traditional alarm using a wet sensor mat on the bed attached to an alarm bell out of reach of the child, and a mini alarm system incorporating a tiny perineal wet sensor attached to a small alarm worn on the child's clothing. A quota allocation system ensured comparability between the two treatment groups. The children were encouraged to use the alarm for four months. Both alarms were equally effective in helping children to become dry. There was no significant difference between the number of children unable to comply with treatment or to be helped by each alarm. The rate of acquisition of dryness was similar for the two groups. The traditional standard alarm was sturdier, more dependable, and easier to maintain, but the mini alarm had some advantages, particularly for girls. Both types of alarm are recommended for general use. Images Fig 1 Fig 2 PMID:2658853
Representing Operational Modes for Situation Awareness
NASA Astrophysics Data System (ADS)
Kirchhübel, Denis; Lind, Morten; Ravn, Ole
2017-01-01
Operating complex plants is an increasingly demanding task for human operators. Diagnosis of and reaction to on-line events requires the interpretation of real time data. Vast amounts of sensor data as well as operational knowledge about the state and design of the plant are necessary to deduct reasonable reactions to abnormal situations. Intelligent computational support tools can make the operator’s task easier, but they require knowledge about the overall system in form of some model. While tools used for fault-tolerant control design based on physical principles and relations are valuable tools for designing robust systems, the models become too complex when considering the interactions on a plant-wide level. The alarm systems meant to support human operators in the diagnosis of the plant-wide situation on the other hand fail regularly in situations where these interactions of systems lead to many related alarms overloading the operator with alarm floods. Functional modelling can provide a middle way to reduce the complexity of plant-wide models by abstracting from physical details to more general functions and behaviours. Based on functional models the propagation of failures through the interconnected systems can be inferred and alarm floods can potentially be reduced to their root-cause. However, the desired behaviour of a complex system changes due to operating procedures that require more than one physical and functional configuration. In this paper a consistent representation of possible configurations is deduced from the analysis of an exemplary start-up procedure by functional models. The proposed interpretation of the modelling concepts simplifies the functional modelling of distinct modes. The analysis further reveals relevant links between the quantitative sensor data and the qualitative perspective of the diagnostics tool based on functional models. This will form the basis for the ongoing development of a novel real-time diagnostics system based on the on-line adaptation of the underlying MFM model.
40 CFR 264.34 - Access to communications or alarm system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Access to communications or alarm... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... operation must have immediate access to an internal alarm or emergency communication device, either directly...
An explosives detection system for airline security using coherent x-ray scattering technology
NASA Astrophysics Data System (ADS)
Madden, Robert W.; Mahdavieh, Jacob; Smith, Richard C.; Subramanian, Ravi
2008-08-01
L-3 Communications Security and Detection Systems (SDS) has developed a new system for automated alarm resolution in airline baggage Explosive Detection Systems (EDS) based on coherent x-ray scattering spectroscopy. The capabilities of the system were demonstrated in tests with concealed explosives at the Transportation Security Laboratory and airline passenger baggage at Orlando International Airport. The system uses x-ray image information to identify suspicious objects and performs targeted diffraction measurements to classify them. This extra layer of detection capability affords a significant reduction in the rate of false alarm objects that must presently be resolved by opening passenger bags for hand inspection.
Morris, J.M.
1958-11-01
A vlsual alarm system, particularly a system incorporating a gas-fllled diode glow bulb, for indicating a minor alarm and also a major alarm is presented. In operation, the disclosed system responds to a signal indlcative of a caution condition by applying a d-c voltage across the glow bulb to induce a glow at one electrode. If a signal indicative of a critlcal condition is received, the system applies an a-c voltage across tbe glow bulb to produce a glow discharge at each electrode.
Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa
2015-02-09
False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.
Detection and quantification system for monitoring instruments
Dzenitis, John M [Danville, CA; Hertzog, Claudia K [Houston, TX; Makarewicz, Anthony J [Livermore, CA; Henderer, Bruce D [Livermore, CA; Riot, Vincent J [Oakland, CA
2008-08-12
A method of detecting real events by obtaining a set of recent signal results, calculating measures of the noise or variation based on the set of recent signal results, calculating an expected baseline value based on the set of recent signal results, determining sample deviation, calculating an allowable deviation by multiplying the sample deviation by a threshold factor, setting an alarm threshold from the baseline value plus or minus the allowable deviation, and determining whether the signal results exceed the alarm threshold.
Recent Results on "Approximations to Optimal Alarm Systems for Anomaly Detection"
NASA Technical Reports Server (NTRS)
Martin, Rodney Alexander
2009-01-01
An optimal alarm system and its approximations may use Kalman filtering for univariate linear dynamic systems driven by Gaussian noise to provide a layer of predictive capability. Predicted Kalman filter future process values and a fixed critical threshold can be used to construct a candidate level-crossing event over a predetermined prediction window. An optimal alarm system can be designed to elicit the fewest false alarms for a fixed detection probability in this particular scenario.
ERIC Educational Resources Information Center
Rushton, Erik; Ryan, Emily; Swift, Charles
After reading the story "Dear Mr. Henshaw" by Beverly Cleary, students build an alarm system for something in the classroom as the main character, Leigh, does to protect his lunchbox from thieves. Students learn about alarms and use their creativity to create an alarm system to protect their lockers, desk, or classroom door. This activity uses a…
NASA Astrophysics Data System (ADS)
Segoni, Samuele; Rosi, Ascanio; Lagomarsino, Daniela; Fanti, Riccardo; Casagli, Nicola
2018-03-01
We communicate the results of a preliminary investigation aimed at improving a state-of-the-art RSLEWS (regional-scale landslide early warning system) based on rainfall thresholds by integrating mean soil moisture values averaged over the territorial units of the system. We tested two approaches. The simplest can be easily applied to improve other RSLEWS: it is based on a soil moisture threshold value under which rainfall thresholds are not used because landslides are not expected to occur. Another approach deeply modifies the original RSLEWS: thresholds based on antecedent rainfall accumulated over long periods are substituted with soil moisture thresholds. A back analysis demonstrated that both approaches consistently reduced false alarms, while the second approach reduced missed alarms as well.
Algorithm of reducing the false positives in IDS based on correlation Analysis
NASA Astrophysics Data System (ADS)
Liu, Jianyi; Li, Sida; Zhang, Ru
2018-03-01
This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.
Spiny lobsters detect conspecific blood-borne alarm cues exclusively through olfactory sensilla.
Shabani, Shkelzen; Kamio, Michiya; Derby, Charles D
2008-08-01
When attacked by predators, diverse animals actively or passively release molecules that evoke alarm and related anti-predatory behavior by nearby conspecifics. The actively released molecules are alarm pheromones, whereas the passively released molecules are alarm cues. For example, many insects have alarm-signaling systems that involve active release of alarm pheromones from specialized glands and detection of these signals using specific sensors. Many crustaceans passively release alarm cues, but the nature of the cues, sensors and responses is poorly characterized. Here we show in laboratory and field experiments that injured Caribbean spiny lobsters, Panulirus argus, passively release alarm cues via blood (hemolymph) that induce alarm responses in the form of avoidance and suppression of feeding. These cues are detected exclusively through specific olfactory chemosensors, the aesthetasc sensilla. The alarm cues for Caribbean spiny lobsters are not unique to the species but do show some phylogenetic specificity: P. argus responds primarily with alarm behavior to conspecific blood, but with mixed alarm and appetitive behaviors to blood from the congener Panulirus interruptus, or with appetitive behaviors to blood from the blue crab Callinectes sapidus. This study lays the foundation for future neuroethological studies of alarm cue systems in this and other decapod crustaceans.
33 CFR 146.105 - General alarm system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... manned facility must have a general alarm system. When operated, this system shall be audible in all... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false General alarm system. 146.105 Section 146.105 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
Predictive Modeling of Cardiac Ischemia
NASA Technical Reports Server (NTRS)
Anderson, Gary T.
1996-01-01
The goal of the Contextual Alarms Management System (CALMS) project is to develop sophisticated models to predict the onset of clinical cardiac ischemia before it occurs. The system will continuously monitor cardiac patients and set off an alarm when they appear about to suffer an ischemic episode. The models take as inputs information from patient history and combine it with continuously updated information extracted from blood pressure, oxygen saturation and ECG lines. Expert system, statistical, neural network and rough set methodologies are then used to forecast the onset of clinical ischemia before it transpires, thus allowing early intervention aimed at preventing morbid complications from occurring. The models will differ from previous attempts by including combinations of continuous and discrete inputs. A commercial medical instrumentation and software company has invested funds in the project with a goal of commercialization of the technology. The end product will be a system that analyzes physiologic parameters and produces an alarm when myocardial ischemia is present. If proven feasible, a CALMS-based system will be added to existing heart monitoring hardware.
NASA Technical Reports Server (NTRS)
Stute, Robert A. (Inventor); Galloway, F. Houston (Inventor); Medelius, Pedro J. (Inventor); Swindle, Robert W. (Inventor); Bierman, Tracy A. (Inventor)
1996-01-01
A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.
A Human Factors Perspective on Alarm System Research and Development 2000 to 2010
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curt Braun; John Grimes; Eric Shaver
By definition, alarms serve to notify human operators of out-of-parameter conditions that could threaten equipment, the environment, product quality and, of course, human life. Given the complexities of industrial systems, human machine interfaces, and the human operator, the understanding of how alarms and humans can best work together to prevent disaster is continually developing. This review examines advances in alarm research and development from 2000 to 2010 and includes the writings of trade professionals, engineering and human factors researchers, and standards organizations with the goal of documenting advances in alarms system design, research, and implementation.
Sequence and batch language programs and alarm-related ``C`` programs for the 242-A MCS. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, J.F.
1995-03-01
A Distributive Process Control system was purchased by Project B-534, ``242-A Evaporator/Crystallizer Upgrades``. This control system, called the Monitor and Control System (MCS), was installed in the 242-A Evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict themore » overall process. To do this, WTSE developed a second alarm scheme which uses special programs, annunciator keys, and process graphics. The special programs are written in two languages; Sequence and Batch Language (SABL), and ``C`` language. The WTSE-developed alarm scheme works as described below: SABL relates signals and alarms to the annunciator keys, called SKID keys. When an alarm occurs, a SABL program causes a SKID key to flash, and if the alarm is of yellow or white priority then a ``C`` program turns on an audible horn (the D/3 system uses a different audible horn for the red priority alarms). The horn and flashing key draws the attention of the operator.« less
Chancey, Eric T; Bliss, James P; Yamani, Yusuke; Handley, Holly A H
2017-05-01
This study provides a theoretical link between trust and the compliance-reliance paradigm. We propose that for trust mediation to occur, the operator must be presented with a salient choice, and there must be an element of risk for dependence. Research suggests that false alarms and misses affect dependence via two independent processes, hypothesized as trust in signals and trust in nonsignals. These two trust types manifest in categorically different behaviors: compliance and reliance. Eighty-eight participants completed a primary flight task and a secondary signaling system task. Participants evaluated their trust according to the informational bases of trust: performance, process, and purpose. Participants were in a high- or low-risk group. Signaling systems varied by reliability (90%, 60%) within subjects and error bias (false alarm prone, miss prone) between subjects. False-alarm rate affected compliance but not reliance. Miss rate affected reliance but not compliance. Mediation analyses indicated that trust mediated the relationship between false-alarm rate and compliance. Bayesian mediation analyses favored evidence indicating trust did not mediate miss rate and reliance. Conditional indirect effects indicated that factors of trust mediated the relationship between false-alarm rate and compliance (i.e., purpose) and reliance (i.e., process) but only in the high-risk group. The compliance-reliance paradigm is not the reflection of two types of trust. This research could be used to update training and design recommendations that are based upon the assumption that trust causes operator responses regardless of error bias.
Microprocessor-based multichannel flutter monitor using dynamic strain gage signals
NASA Technical Reports Server (NTRS)
Smalley, R. R.
1976-01-01
Two microprocessor-based multichannel monitors for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines were described. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs. frequency limit profiles. Each system design is described with details on design trade-offs, hardware, software, and operating experience.
Alarm acknowledgement in a nuclear plant control room
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
Alarm acknowledgment can be made not only at the alarm tile array of a given console but via other touch sensitive alarm indications in the screen displays of the monitoring system at the same or other consoles; also, touching one tile can acknowledge multiple alarm sources.
46 CFR 154.1842 - Cargo system: Controls and alarms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Cargo system: Controls and alarms. 154.1842 Section 154... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1842 Cargo system: Controls and alarms. The master shall ensure that the cargo emergency shut-down system and the...
46 CFR 154.1842 - Cargo system: Controls and alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo system: Controls and alarms. 154.1842 Section 154... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1842 Cargo system: Controls and alarms. The master shall ensure that the cargo emergency shut-down system and the...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2014-10-01 2014-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2013-10-01 2013-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2011-10-01 2011-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2012-10-01 2012-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
46 CFR 76.35-10 - Location and spacing of manual alarm boxes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2010-10-01 2010-10-01 false Location and spacing of manual alarm boxes. 76.35-10...
Textile sensors for stab and cut detection
NASA Astrophysics Data System (ADS)
Graßmann, C.; Obermann, M.; Lempa, E.; Bache, T.; Siegel, P. K.; Freyer, T.; Paschko, S.; Beyer, T.; Kirsche, M.; Schwarz-Pfeiffer, A.
2017-10-01
Manufacturers are aiming for more flexible and lightweight protective clothing to increase wearing comfort. A cardigan with a knitted stab-resistant inlay and an alarm system is presented. The stab-resistant inlay is based on a multilayer ultra-high molecular weight poly ethylene (UHMW-PE) fabric. Stab resistance was evaluated according to the standard of the Association of Test Laboratories for Bullet, Stab or Pike Resistant Materials and Construction Standard (VPAM 2011). Furthermore sensors for the detection of cuts and pressure were integrated. Both sensors can trigger alarms if the wearer is attacked. Normal pressure occurring through leaning on a wall or sitting is filtered out and does not trigger an alarm.
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...
46 CFR 169.732 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...
46 CFR 169.732 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...
Remote video assessment for missile launch facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, G.G.; Stewart, W.A.
1995-07-01
The widely dispersed, unmanned launch facilities (LFs) for land-based ICBMs (intercontinental ballistic missiles) currently do not have visual assessment capability for existing intrusion alarms. The security response force currently must assess each alarm on-site. Remote assessment will enhance manpower, safety, and security efforts. Sandia National Laboratories was tasked by the USAF Electronic Systems Center to research, recommend, and demonstrate a cost-effective remote video assessment capability at missile LFs. The project`s charter was to provide: system concepts; market survey analysis; technology search recommendations; and operational hardware demonstrations for remote video assessment from a missile LF to a remote security center viamore » a cost-effective transmission medium and without using visible, on-site lighting. The technical challenges of this project were to: analyze various video transmission media and emphasize using the existing missile system copper line which can be as long as 30 miles; accentuate and extremely low-cost system because of the many sites requiring system installation; integrate the video assessment system with the current LF alarm system; and provide video assessment at the remote sites with non-visible lighting.« less
Modelling the future Israel EEWS performance using synthetic catalogue
NASA Astrophysics Data System (ADS)
Pinsky, V.
2017-10-01
In 2012 June, Israel government decided about building an Earthquake Early Warning System (EEWS) in the country. The network configuration suggested was to be a staggered line of ˜100 stations along the regional main faults: Dead Sea fault and Carmel fault and additional ˜22 stations spread over the country. The EEWS alarm system should have to utilize two approaches: the P-wave-based algorithm combined with the S-threshold method. The former utilizes first wave arrivals to several closest stations for prompt location and the three initial seconds of the waveform data for magnitude estimation. The latter issues alarm when the surface shaking (velocity or acceleration) exceeds the relatively high threshold corresponding to a magnitude 5 earthquake at a short distance of about 10 km at least for the two neighbouring stations. For each of the approaches and for a reasonable combination of them, we simulate the EEWS performance based on a synthetic catalogue. The input seismicity parameters for the processing are extracted from the real instrumental catalogue. Using a general ground-motion prediction equations for peak ground accelaration, τc and Pd we then evaluate how false and missed alarm rates depend on the corresponding thresholds. Practically, in turn, these dependencies approve choosing initial thresholds for the EEWS providing suitable false and missed alarms rates.
2011-02-01
vacuum swing adsorption (VSA). This system would also be extremely quiet while operating. In applications where a pressurized air feed is available...review of the latest data set. 02 Apr 10, Friday - Status: OK. Tinker AFB reported a FAL alarm occurs when the compressor isn’t pumping oxygen. The...FAL alarm terminates when the compressor starts pumping oxygen. APCI/Ceramatec confirmed this occurrence is normal operation, however, it isn’t
33 CFR 149.665 - What are the requirements for a general alarm system?
Code of Federal Regulations, 2011 CFR
2011-07-01
...? Each pumping platform complex must have a general alarm system that: (a) Is capable of being manually... general alarm system? 149.665 Section 149.665 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT Design...
33 CFR 149.665 - What are the requirements for a general alarm system?
Code of Federal Regulations, 2010 CFR
2010-07-01
...? Each pumping platform complex must have a general alarm system that: (a) Is capable of being manually... general alarm system? 149.665 Section 149.665 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT Design...
Raboshchuk, Ganna; Nadeu, Climent; Jancovic, Peter; Lilja, Alex Peiro; Kokuer, Munevver; Munoz Mahamud, Blanca; Riverola De Veciana, Ana
2018-01-01
A large number of alarm sounds triggered by biomedical equipment occur frequently in the noisy environment of a neonatal intensive care unit (NICU) and play a key role in providing healthcare. In this paper, our work on the development of an automatic system for detection of acoustic alarms in that difficult environment is presented. Such automatic detection system is needed for the investigation of how a preterm infant reacts to auditory stimuli of the NICU environment and for an improved real-time patient monitoring. The approach presented in this paper consists of using the available knowledge about each alarm class in the design of the detection system. The information about the frequency structure is used in the feature extraction stage, and the time structure knowledge is incorporated at the post-processing stage. Several alternative methods are compared for feature extraction, modeling, and post-processing. The detection performance is evaluated with real data recorded in the NICU of the hospital, and by using both frame-level and period-level metrics. The experimental results show that the inclusion of both spectral and temporal information allows to improve the baseline detection performance by more than 60%.
Nadeu, Climent; Jančovič, Peter; Lilja, Alex Peiró; Köküer, Münevver; Muñoz Mahamud, Blanca; Riverola De Veciana, Ana
2018-01-01
A large number of alarm sounds triggered by biomedical equipment occur frequently in the noisy environment of a neonatal intensive care unit (NICU) and play a key role in providing healthcare. In this paper, our work on the development of an automatic system for detection of acoustic alarms in that difficult environment is presented. Such automatic detection system is needed for the investigation of how a preterm infant reacts to auditory stimuli of the NICU environment and for an improved real-time patient monitoring. The approach presented in this paper consists of using the available knowledge about each alarm class in the design of the detection system. The information about the frequency structure is used in the feature extraction stage, and the time structure knowledge is incorporated at the post-processing stage. Several alternative methods are compared for feature extraction, modeling, and post-processing. The detection performance is evaluated with real data recorded in the NICU of the hospital, and by using both frame-level and period-level metrics. The experimental results show that the inclusion of both spectral and temporal information allows to improve the baseline detection performance by more than 60%. PMID:29404227
46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned ocean...
46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned ocean...
46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned ocean...
46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned ocean...
46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned ocean...
Onsite Portable Alarm System - Its Merit and Application
NASA Astrophysics Data System (ADS)
Saita, J.; Sato, T.; Nakamura, Y.
2007-12-01
Recently an existence of the earthquake early warning system (EEWS) becomes popular. In general, the EEWS will be installed in a fixed observation site and it may consist of several separated components such as a sensing portion, A/D converter, an information processing potion and so on. The processed information for warning may be transmitted to network via fixed communication line, and therefore this kind of alarm system is called as Network Alarm System. On the other hand, after the severe earthquake damage, it is very important to save the disaster victims immediately. These rescue staffs are also under the risk of aftershocks and need a local alarm not depending on the network, so this kind of alarm can be called as Onsite Alarm. But the common early warning system is too complex to set onsite temporary, and even if possible to install, the alarm is too late to receive at the epicentral area. However, the new generation earthquake early warning system FREQL can issue the P wave alarm by minimum 0.2 seconds after P wave detection. And FREQL is characterized as the unique all-in-one seismometer with power unit. At the time of the 2004 Niigata-Ken-Chuetsu earthquake, a land slide attacked a car just passing. A hyper rescue team of Tokyo Fire Department pulled the survivor, one baby, from the land slide area. During their activity the rescue team was exposed to the risk of secondary hazards caused by the aftershocks. It was clear that it is necessary to use a portable warning system to issue the onsite P wave alarm. Because FREQL was originally developed as portable equipment, Tokyo Fire Department asked us to modify it to the portable equipment with the loud sound and the light signal. In this moment, this portable FREQL has equipped in nation wide. When the hyper rescue team of Tokyo Fire Department was sent to Pakistan as a task force for rescue work of the 2005 Pakistan earthquake, the portable FREQL was used as important onsite portable warning system and P wave alarms was actually issued by three times during the rescue work. Although this is one example for the actual application of portable onsite alarm, it is possible to apply the other field as the construction field. In this presentation, Portable Onsite Alarm is discussed from views of its necessity and application.
Development library of finite elements for computer-aided design system of reed sensors
NASA Astrophysics Data System (ADS)
Kozlov, A. S.; Shmakov, N. A.; Tkalich, V. L.; Labkovskaia, R. I.; Kalinkina, M. E.; Pirozhnikova, O. I.
2018-05-01
The article is devoted to the development of a modern highly reliable element base of devices for security and fire alarm systems, in particular, to the improvement of the quality of contact cores (reed and membrane) of reed sensors. Modeling of elastic sensitive elements uses quadrangular elements of plates and shells, considered in the system of curvilinear orthogonal coordinates. The developed mathematical models and the formed finite element library are designed for systems of automated design of reed switch detectors to create competitive devices alarms. The finite element library is used for the automated system production of reed switch detectors both in series production and in the implementation of individual orders.
Orthos, an alarm system for the ALICE DAQ operations
NASA Astrophysics Data System (ADS)
Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Denes, Ervin; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; von Haller, Barthelemy
2012-12-01
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.
46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... percent liquid full and without causing the pressure in the loading lines to exceed the design pressure... 46 Shipping 5 2010-10-01 2010-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under...
46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... percent liquid full and without causing the pressure in the loading lines to exceed the design pressure... 46 Shipping 5 2013-10-01 2013-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under...
46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... percent liquid full and without causing the pressure in the loading lines to exceed the design pressure... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under...
46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... percent liquid full and without causing the pressure in the loading lines to exceed the design pressure... 46 Shipping 5 2011-10-01 2011-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under...
46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... percent liquid full and without causing the pressure in the loading lines to exceed the design pressure... 46 Shipping 5 2014-10-01 2014-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under...
46 CFR 113.25-7 - Power supply overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply overcurrent protection. 113.25-7 Section... COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-7 Power supply overcurrent protection. (a) If the general emergency alarm system is the only load supplied by the general...
46 CFR 113.25-7 - Power supply overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Power supply overcurrent protection. 113.25-7 Section... COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-7 Power supply overcurrent protection. (a) If the general emergency alarm system is the only load supplied by the general...
Sensory Overload and Technology in Critical Care.
Wung, Shu-Fen; Malone, Daniel C; Szalacha, Laura
2018-06-01
In this focus group study, we identified issues associated with sensory overload from medical technology alarms/alerts for intensive care unit nurses. Participants indicated that alarms from cardiopulmonary monitors, ventilators, and intravenous pumps contributed the most to sensory overload and, yet, these alarms were also deemed the most helpful. Alerts/alarms from electronic health records and medication dispensing systems were rated low in contributing to sensory overload, as well as being the least helpful. Specific device/technology barriers, related to device alerts/alarms, are detailed. Future user-centered and integrated improvements in alarm systems associated with medical devices in the intensive care unit are needed. Copyright © 2018 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...
Types and Frequency of Infusion Pump Alarms: Protocol for a Retrospective Data Analysis.
Glover, Kevin R; Vitoux, Rachel R; Schuster, Catherine; Curtin, Christopher R
2018-06-14
The variety of alarms from all types of medical devices has increased from 6 to 40 in the last three decades, with today's most critically ill patients experiencing as many as 45 alarms per hour. Alarm fatigue has been identified as a critical safety issue for clinical staff that can lead to potentially dangerous delays or nonresponse to actionable alarms, resulting in serious patient injury and death. To date, most research on medical device alarms has focused on the nonactionable alarms of physiological monitoring devices. While there have been some reports in the literature related to drug library alerts during the infusion pump programing sequence, research related to the types and frequencies of actionable infusion pump alarms remains largely unexplored. The objectives of this study protocol are to establish baseline data related to the types and frequency of infusion pump alarms from the B. Braun Outlook 400ES Safety Infusion System with the accompanying DoseTrac Infusion Management Software. The most recent consecutive 60-day period of backup hospital data received between April 2014 and February 2017 from 32 United States-based hospitals will be selected for analysis. Microsoft SQL Server (2012 - 11.0.5343.0 X64) will be used to manage the data with unique code written to sort data and perform descriptive analyses. A validated data management methodology will be utilized to clean and analyze the data. Data management procedures will include blinding, cleaning, and review of existing infusion data within the DoseTrac Infusion Management Software databases at each hospital. Patient-identifying data will be removed prior to merging into a dedicated and secure data repository. This pooled data will then be analyzed. This exploratory study will analyze the aggregate alarm data for each hospital by care area, drug infused, time of day, and day of week, including: overall infusion pump alarm frequency (number of alarms per active infusion), duration of alarms (average, range, median), and type and frequency of alarms distributed by care area. Infusion pump alarm data collected and analyzed in this study will be used to help establish a baseline of infusion pump alarm types and relative frequencies. Understanding the incidences and characteristics of infusion pump alarms will result in more informed quality improvement recommendations to decrease and/or modify infusion pump alarms, and potentially reduce clinical staff alarm fatigue and improve patient safety. . RR1-10.2196/10446. ©Kevin R Glover, Rachel R Vitoux, Catherine Schuster, Christopher R Curtin. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 14.06.2018.
ERIC Educational Resources Information Center
Haworth-Roberts, A., Ed.
Greater use of expensive equipment by schools has also increased the potential for vandalism and theft, giving an increased role to intruder alarm systems. This document provides guidance on the management and technical aspects of forming policies for installing and operating intruder alarm systems in educational buildings. Also provided are…
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-14
... Bridge Navigational Watch Alarm Systems (BNWAS) Aboard U.S. Flagged Vessels AGENCY: Coast Guard, DHS... carriage standards for Bridge Navigational Watch Alarm Systems (BNWAS), in accordance with the Articles of... carriage of a BNWAS should not lead to a reduction in manning levels on the bridge. Consistent with the...
Model-Based Anomaly Detection for a Transparent Optical Transmission System
NASA Astrophysics Data System (ADS)
Bengtsson, Thomas; Salamon, Todd; Ho, Tin Kam; White, Christopher A.
In this chapter, we present an approach for anomaly detection at the physical layer of networks where detailed knowledge about the devices and their operations is available. The approach combines physics-based process models with observational data models to characterize the uncertainties and derive the alarm decision rules. We formulate and apply three different methods based on this approach for a well-defined problem in optical network monitoring that features many typical challenges for this methodology. Specifically, we address the problem of monitoring optically transparent transmission systems that use dynamically controlled Raman amplification systems. We use models of amplifier physics together with statistical estimation to derive alarm decision rules and use these rules to automatically discriminate between measurement errors, anomalous losses, and pump failures. Our approach has led to an efficient tool for systematically detecting anomalies in the system behavior of a deployed network, where pro-active measures to address such anomalies are key to preventing unnecessary disturbances to the system's continuous operation.
NASA Astrophysics Data System (ADS)
Strączkiewicz, M.; Barszcz, T.; Jabłoński, A.
2015-07-01
All commonly used condition monitoring systems (CMS) enable defining alarm thresholds that enhance efficient surveillance and maintenance of dynamic state of machinery. The thresholds are imposed on the measured values such as vibration-based indicators, temperature, pressure, etc. For complex machinery such as wind turbine (WT) the total number of thresholds might be counted in hundreds multiplied by the number of operational states. All the parameters vary not only due to possible machinery malfunctions, but also due to changes in operating conditions and these changes are typically much stronger than the former ones. Very often, such a behavior may lead to hundreds of false alarms. Therefore, authors propose a novel approach based on parameterized description of the threshold violation. For this purpose the novelty and severity factors are introduced. The first parameter refers to the time of violation occurrence while the second one describes the impact of the indicator-increase to the entire machine. Such approach increases reliability of the CMS by providing the operator with the most useful information of the system events. The idea of the procedure is presented on a simulated data similar to those from a wind turbine.
77 FR 33859 - Carbon Dioxide Fire Suppression Systems on Commercial Vessels
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-07
...-based systems under NFPA 12 and its wide and inexpensive availability. The success and availability of... because of the availability of better alternatives, and that we should ban gas- driven alarms and...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
Emergency Vehicle Alarm System for Deaf Drivers by Using LEDs and Vibration Devices
NASA Astrophysics Data System (ADS)
Kuwahara, Noriaki; Morimoto, Kazunari; Kozuki, Kazumasa; Kawamura, Tomonori
We are developing the emergency vehicle alarm system for deaf drivers by using LEDs and vibration devices. In order to design the alarm for deaf drivers, we have conducted basic experiment in order to evaluate perceptual characteristic on visibility of LED.
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
29 CFR 1910.165 - Employee alarm systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...
Accuracy of WAAS-Enabled GPS-RF Warning Signals When Crossing a Terrestrial Geofence
Grayson, Lindsay M.; Keefe, Robert F.; Tinkham, Wade T.; Eitel, Jan U. H.; Saralecos, Jarred D.; Smith, Alistair M. S.; Zimbelman, Eloise G.
2016-01-01
Geofences are virtual boundaries based on geographic coordinates. When combined with global position system (GPS), or more generally global navigation satellite system (GNSS) transmitters, geofences provide a powerful tool for monitoring the location and movements of objects of interest through proximity alarms. However, the accuracy of geofence alarms in GNSS-radio frequency (GNSS-RF) transmitter receiver systems has not been tested. To achieve these goals, a cart with a GNSS-RF locator was run on a straight path in a balanced factorial experiment with three levels of cart speed, three angles of geofence intersection, three receiver distances from the track, and three replicates. Locator speed, receiver distance and geofence intersection angle all affected geofence alarm accuracy in an analysis of variance (p = 0.013, p = 2.58 × 10−8, and p = 0.0006, respectively), as did all treatment interactions (p < 0.0001). Slower locator speed, acute geofence intersection angle, and closest receiver distance were associated with reduced accuracy of geofence alerts. PMID:27322287
Accuracy of WAAS-Enabled GPS-RF Warning Signals When Crossing a Terrestrial Geofence.
Grayson, Lindsay M; Keefe, Robert F; Tinkham, Wade T; Eitel, Jan U H; Saralecos, Jarred D; Smith, Alistair M S; Zimbelman, Eloise G
2016-06-18
Geofences are virtual boundaries based on geographic coordinates. When combined with global position system (GPS), or more generally global navigation satellite system (GNSS) transmitters, geofences provide a powerful tool for monitoring the location and movements of objects of interest through proximity alarms. However, the accuracy of geofence alarms in GNSS-radio frequency (GNSS-RF) transmitter receiver systems has not been tested. To achieve these goals, a cart with a GNSS-RF locator was run on a straight path in a balanced factorial experiment with three levels of cart speed, three angles of geofence intersection, three receiver distances from the track, and three replicates. Locator speed, receiver distance and geofence intersection angle all affected geofence alarm accuracy in an analysis of variance (p = 0.013, p = 2.58 × 10(-8), and p = 0.0006, respectively), as did all treatment interactions (p < 0.0001). Slower locator speed, acute geofence intersection angle, and closest receiver distance were associated with reduced accuracy of geofence alerts.
Justus, Alan L
2015-05-01
This paper presents technically-based techniques to deal with nuisance personnel contamination monitor (PCM) alarms. The techniques derive from the fundamental physical characteristics of radon progeny. Some PCM alarms, although valid alarms and not actually "false," could be due to nuisance naturally-occurring radionuclides (i.e., radon progeny). Based on certain observed characteristics of the radon progeny, several prompt techniques are discussed that could either remediate or at least mitigate the problem of nuisance alarms. Examples are provided which demonstrate the effective use of the techniques.
False Alarms and Overmonitoring: Major Factors in Alarm Fatigue Among Labor Nurses.
Simpson, Kathleen Rice; Lyndon, Audrey
2018-06-08
Nurses can be exposed to hundreds of alarms during their shift, contributing to alarm fatigue. The purposes were to explore similarities and differences in perceptions of clinical alarms by labor nurses caring for generally healthy women compared with perceptions of adult intensive care unit (ICU) and neonatal ICU nurses caring for critically ill patients and to seek nurses' suggestions for potential improvements. Nurses were asked via focus groups about the utility of clinical alarms from medical devices. There was consensus that false alarms and too many devices generating alarms contributed to alarm fatigue, and most alarms lacked clinical relevance. Nurses identified certain types of alarms that they responded to immediately, but the vast majority of the alarms did not contribute to their clinical assessment or planned nursing care. Monitoring only those patients who need it and only those physiologic values that are warranted, based on patient condition, may decrease alarm burden.
46 CFR 111.33-7 - Alarms and shutdowns.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power semiconductor...
46 CFR 111.33-7 - Alarms and shutdowns.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power semiconductor...
46 CFR 111.33-7 - Alarms and shutdowns.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power semiconductor...
46 CFR 111.33-7 - Alarms and shutdowns.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power semiconductor...
46 CFR 113.43-5 - Power supply.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm...
46 CFR 113.43-5 - Power supply.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm...
46 CFR 113.43-5 - Power supply.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm...
46 CFR 113.10-1 - Approved equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...
46 CFR 113.10-1 - Approved equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...
46 CFR 113.10-1 - Approved equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...
46 CFR 113.10-1 - Approved equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...
46 CFR 113.10-1 - Approved equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...
46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fire detecting, manual alarm, and supervised patrol... AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 95.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire detecting, manual alarm, and supervised patrol... AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 95.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fire detecting, manual alarm, and supervised patrol... AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 95.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humberto E. Garcia
This paper illustrates safeguards benefits that process monitoring (PM) can have as a diversion deterrent and as a complementary safeguards measure to nuclear material accountancy (NMA). In order to infer the possible existence of proliferation-driven activities, the objective of NMA-based methods is often to statistically evaluate materials unaccounted for (MUF) computed by solving a given mass balance equation related to a material balance area (MBA) at every material balance period (MBP), a particular objective for a PM-based approach may be to statistically infer and evaluate anomalies unaccounted for (AUF) that may have occurred within a MBP. Although possibly being indicativemore » of proliferation-driven activities, the detection and tracking of anomaly patterns is not trivial because some executed events may be unobservable or unreliably observed as others. The proposed similarity between NMA- and PM-based approaches is important as performance metrics utilized for evaluating NMA-based methods, such as detection probability (DP) and false alarm probability (FAP), can also be applied for assessing PM-based safeguards solutions. To this end, AUF count estimates can be translated into significant quantity (SQ) equivalents that may have been diverted within a given MBP. A diversion alarm is reported if this mass estimate is greater than or equal to the selected value for alarm level (AL), appropriately chosen to optimize DP and FAP based on the particular characteristics of the monitored MBA, the sensors utilized, and the data processing method employed for integrating and analyzing collected measurements. To illustrate the application of the proposed PM approach, a protracted diversion of Pu in a waste stream was selected based on incomplete fuel dissolution in a dissolver unit operation, as this diversion scenario is considered to be problematic for detection using NMA-based methods alone. Results demonstrate benefits of conducting PM under a system-centric strategy that utilizes data collected from a system of sensors and that effectively exploits known characterizations of sensors and facility operations in order to significantly improve anomaly detection, reduce false alarm, and enhance assessment robustness under unreliable partial sensor information.« less
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
46 CFR 113.27-1 - Engineers' assistance-needed alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
24 CFR 3285.703 - Smoke alarms.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...
NASA Astrophysics Data System (ADS)
Leahy, Kevin; Gallagher, Colm; Bruton, Ken; O'Donovan, Peter; O'Sullivan, Dominic T. J.
2017-11-01
Using 10-minute wind turbine SCADA data for fault prediction offers an attractive way of gaining additional prognostic capabilities without needing to invest in extra hardware. To use these data-driven methods effectively, the historical SCADA data must be labelled with the periods when the turbine was in faulty operation as well the sub-system the fault was attributed to. Manually identifying faults using maintenance logs can be effective, but is also highly time consuming and tedious due to the disparate nature of these logs across manufacturers, operators and even individual maintenance events. Turbine alarm systems can help to identify these periods, but the sheer volume of alarms and false positives generated makes analysing them on an individual basis ineffective. In this work, we present a new method for automatically identifying historical stoppages on the turbine using SCADA and alarms data. Each stoppage is associated with either a fault in one of the turbine’s sub-systems, a routine maintenance activity, a grid-related event or a number of other categories. This is then checked against maintenance logs for accuracy and the labelled data fed into a classifier for predicting when these stoppages will occur. Results show that the automated labelling process correctly identifies each type of stoppage, and can be effectively used for SCADA-based prediction of turbine faults.
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
46 CFR 130.460 - Placement of machinery alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST... MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a... must provide battery power for the alarm required by § 130.460(a)(8) of this subpart. ...
40 CFR 265.34 - Access to communications or alarm system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Access to communications or alarm..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm... involved in the operation must have immediate access to an internal alarm or emergency communication device...
Increasing smoke alarm operability through theory-based health education: a randomised trial
Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S
2015-01-01
Background Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Methods Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm’s hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005–2008. Followup visits checked alarm operability in 370 homes (85%) 1–3.5 years after installation. Main outcome measures: number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Results Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Conclusions Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. Trial registration number http://www.clinicaltrials.gov number NCT00139126. PMID:25165090
Sowan, Azizeh Khaled; Reed, Charles Calhoun; Staggers, Nancy
2016-09-30
Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. The audit log is a function of current capabilities of the physiologic monitoring systems, monitor's configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices' log capacity.
Intelligent agent-based intrusion detection system using enhanced multiclass SVM.
Ganapathy, S; Yogesh, P; Kannan, A
2012-01-01
Intrusion detection systems were used in the past along with various techniques to detect intrusions in networks effectively. However, most of these systems are able to detect the intruders only with high false alarm rate. In this paper, we propose a new intelligent agent-based intrusion detection model for mobile ad hoc networks using a combination of attribute selection, outlier detection, and enhanced multiclass SVM classification methods. For this purpose, an effective preprocessing technique is proposed that improves the detection accuracy and reduces the processing time. Moreover, two new algorithms, namely, an Intelligent Agent Weighted Distance Outlier Detection algorithm and an Intelligent Agent-based Enhanced Multiclass Support Vector Machine algorithm are proposed for detecting the intruders in a distributed database environment that uses intelligent agents for trust management and coordination in transaction processing. The experimental results of the proposed model show that this system detects anomalies with low false alarm rate and high-detection rate when tested with KDD Cup 99 data set.
Intelligent Agent-Based Intrusion Detection System Using Enhanced Multiclass SVM
Ganapathy, S.; Yogesh, P.; Kannan, A.
2012-01-01
Intrusion detection systems were used in the past along with various techniques to detect intrusions in networks effectively. However, most of these systems are able to detect the intruders only with high false alarm rate. In this paper, we propose a new intelligent agent-based intrusion detection model for mobile ad hoc networks using a combination of attribute selection, outlier detection, and enhanced multiclass SVM classification methods. For this purpose, an effective preprocessing technique is proposed that improves the detection accuracy and reduces the processing time. Moreover, two new algorithms, namely, an Intelligent Agent Weighted Distance Outlier Detection algorithm and an Intelligent Agent-based Enhanced Multiclass Support Vector Machine algorithm are proposed for detecting the intruders in a distributed database environment that uses intelligent agents for trust management and coordination in transaction processing. The experimental results of the proposed model show that this system detects anomalies with low false alarm rate and high-detection rate when tested with KDD Cup 99 data set. PMID:23056036
Tinnitus as an alarm bell: stress reaction tinnitus model.
Alpini, D; Cesarani, A
2006-01-01
Stress is a significant factor influencing the clinical course of tinnitus. Auditory system is particularly sensitive to the effects of different stress factors (chemical, oxidative, emotional, etc.). Different stages of reaction (alarm, resistance, exhaustion) lead to different characteristics of tinnitus and different therapeutic approaches. Individual characteristics of stress reaction may explain different aspects of tinnitus in various patients with different responses to treatment, despite similar audiological and etiological factors. A model based on individual reactions to stress factors (stress reaction tinnitus model) could explain tinnitus as an alarm signal, just like an 'alarm bell', informing the patient that something potentially dangerous for subject homeostasis is happening. Tinnitus could become a disabling symptom when the subject is chronically exposed to a stress factor and is unable to switch off the alarm. Stress signals, specific for each patient, have to be identified during the 'alarm' phase in order to prevent an evolution toward the 'resistance' and 'exhaustion' phases. In these phases, identification of stressor is no more sufficient, due to the organization of a 'paradoxical auditory memory' and a 'pathologically shifted attention to tinnitus'. Identification of stress reaction phase requires accurate otolaryngology and anamnesis combined with audiological matching tests (Feldman Masking Test, for example) and psychometric questionnaires (Tinnitus Reaction and Tinnitus Cognitive Questionnaires). Copyright (c) 2006 S. Karger AG, Basel.
Wireless boundary monitor system and method
Haynes, H.D.; Ayers, C.W.
1997-12-09
A wireless boundary monitor system used to monitor the integrity of a boundary surrounding an area uses at least two housings having at least one transmitting means for emitting ultrasonic pressure waves to a medium. Each of the housings has a plurality of receiving means for sensing the pressure waves in the medium. The transmitting means and the receiving means of each housing are aimable and communicably linked. At least one of the housings is equipped with a local alarm means for emitting a first alarm indication whereby, when the pressure waves propagating from a transmitting means to a receiving means are sufficiently blocked by an object a local alarm means or a remote alarm means or a combination thereof emit respective alarm indications. The system may be reset either manually or automatically. This wireless boundary monitor system has useful applications in both indoor and outdoor environments. 4 figs.
Wireless boundary monitor system and method
Haynes, Howard D.; Ayers, Curtis W.
1997-01-01
A wireless boundary monitor system used to monitor the integrity of a boundary surrounding an area uses at least two housings having at least one transmitting means for emitting ultrasonic pressure waves to a medium. Each of the housings has a plurality of receiving means for sensing the pressure waves in the medium. The transmitting means and the receiving means of each housing are aimable and communicably linked. At least one of the housings is equipped with a local alarm means for emitting a first alarm indication whereby, when the pressure waves propagating from a transmitting means to a receiving means are sufficiently blocked by an object a local alarm means or a remote alarm means or a combination thereof emit respective alarm indications. The system may be reset either manually or automatically. This wireless boundary monitor system has useful applications in both indoor and outdoor environments.
A rule-based approach for the correlation of alarms to support Disaster and Emergency Management
NASA Astrophysics Data System (ADS)
Gloria, M.; Minei, G.; Lersi, V.; Pasquariello, D.; Monti, C.; Saitto, A.
2009-04-01
Key words: Simple Event Correlator, Agent Platform, Ontology, Semantic Web, Distributed Systems, Emergency Management The importance of recognition of emergency's typology to control the critical situation for security of citizens has been always recognized. It follows this aspect is very important for proper management of a hazardous event. In this work we present a solution for the recognition of emergency's typology adopted by an Italian research project, called CI6 (Centro Integrato per Servizi di Emergenza Innovativi). In our approach, CI6 receives alarms by citizen or people involved in the work (for example: police, operator of 112, and so on). CI6 represents any alarm by a set of information, including a text that describes it and obtained when the user points out the danger, and a pair of coordinates for its location. The system realizes an analysis of text and automatically infers information on the type of emergencies by means a set of parsing rules and rules of inference applied by a independent module: a correlator of events based on their log and called Simple Event Correlator (SEC). SEC, integrated in CI6's platform, is an open source and platform independent event correlation tool. SEC accepts input both files and text derived from standard input, making it flexible because it can be matched to any application that is able to write its output to a file stream. The SEC configuration is stored in text files as rules, each rule specifying an event matching condition, an action list, and optionally a Boolean expression whose truth value decides whether the rule can be applied at a given moment. SEC can produce output events by executing user-specified shell scripts or programs, by writing messages to files, and by various other means. SEC has been successfully applied in various domains like network management, system monitoring, data security, intrusion detection, log file monitoring and analysis, etc; it has been used or integrated with many application as CiscoWorks, HP OpenView NNM and Operation, BMC Patrol, etc. Analysis of text of an alarm can detect some keywords that allow to classify the particular event. The inference rules were developed by means an analysis about news regard real emergency found by web reaserches. We have seen that often a kind of emergency is characterized by more keyword. Keywords are not uniquely associated with a specific emergency, but they can be shared by different types of emergencies (such as. keyword "landslide" can be associated both emergency "landslide" and emergency "Flood"). However, the identification of two or more keywords associated with a particular type of emergency identified in most cases the correct type of emergency. So, for example, if text contains words as "water", "flood", "overflowing", "landslide" o other words belonging to the set of defined keywords or words that have some root of keywords, the system "decides" that this alarm belongs to specific typology, in this case "flood typology". The system has the memory of this information, so if a new alarm is reported and belongs to one of the typology already identified, it proceeds with the comparison of coordinates. The comparison between the centers of the alarms allows to see if they describe an area inscribed in an ideal circle that has centered on the first alarm and radius defined by the typology above mentioned. If this happens the system CI6 creates an emergency that has centered on the centre of that area and typology equal to that of the alarms. It follows that an emergency is represented by at least two alarms. Thus, the system suggests to manager (CI6's user) the possibility that most alarms can concern same events and makes a classification of this event. It is important to stress that CI6 is a system of decision support, hence also this service is limited to providing advice to the user to facilitate his task, leaving him the decision to accept it or not. REFERENCES SEC (Simple Event Correlator), http://kodu.neti.ee/~risto/sec/ M. Gloria,V. Lersi, G. Minei, D. Pasquariello, C. Monti, A. Saitto, "A Semantic WEB Services Platform to support Disaster and Emergency Management", 4th biennial Meeting of International Environmental Modelling and Software Society (iEMSs), 2008
33 CFR 127.201 - Sensing and alarm systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms nearby. (b) Fixed sensors that continuously monitor for LNG vapors must— (1) Be in each enclosed area where vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously...
33 CFR 127.201 - Sensing and alarm systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms nearby. (b) Fixed sensors that continuously monitor for LNG vapors must— (1) Be in each enclosed area where vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously...
33 CFR 127.201 - Sensing and alarm systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms nearby. (b) Fixed sensors that continuously monitor for LNG vapors must— (1) Be in each enclosed area where vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously...
NASA Astrophysics Data System (ADS)
Tsutsumi, Shigeyoshi; Wada, Takahiro; Akita, Tokihiko; Doi, Shun'ichi
Driver's workload tends to be increased during driving under complicated traffic environments like a lane change. In such cases, rear collision warning is effective for reduction of cognitive workload. On the other hand, it is pointed out that false alarm or missing alarm caused by sensor errors leads to decrease of driver' s trust in the warning system and it can result in low efficiency of the system. Suppose that reliability information of the sensor is provided in real-time. In this paper, we propose a new warning method to increase driver' s trust in the system even with low sensor reliability utilizing the sensor reliability information. The effectiveness of the warning methods is shown by driving simulator experiments.
Multi-Target Camera Tracking, Hand-off and Display LDRD 158819 Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Robert J.
2014-10-01
Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn’t lead to more alarms, moremore » monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identify individual moving targets from the background imagery, and then display the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.« less
Multi-target camera tracking, hand-off and display LDRD 158819 final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Robert J.
2014-10-01
Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn't lead to more alarms, moremore » monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identifies individual moving targets from the background imagery, and then displays the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.« less
Hypo- and Hyperglycemic Alarms
Howsmon, Daniel; Bequette, B. Wayne
2015-01-01
Soon after the discovery that insulin regulates blood glucose by Banting and Best in 1922, the symptoms and risks associated with hypoglycemia became widely recognized. This article reviews devices to warn individuals of impending hypo- and hyperglycemia; biosignals used by these devices include electroencephalography, electrocardiography, skin galvanic resistance, diabetes alert dogs, and continuous glucose monitors (CGMs). While systems based on other technology are increasing in performance and decreasing in size, CGM technology remains the best method for both reactive and predictive alarming of hypo- or hyperglycemia. PMID:25931581
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 169.730 - General alarm bell switch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...
46 CFR 111.33-7 - Alarms and shutdowns.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power semiconductor rectifier must have a high temperature alarm or shutdown, except as provided in § 111.33-11. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumidu Wijayasekara; Ondrej Linda; Milos Manic
Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD)more » based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.« less
40 CFR 63.11527 - What are the monitoring requirements for new and existing sources?
Code of Federal Regulations, 2011 CFR
2011-07-01
... alarm that will sound when an increase in relative PM loadings is detected over the alarm set point... operating a bag leak detection system, if an alarm sounds, conduct visual monitoring of the monovent or... maintain a continuous parameter monitoring system (CPMS) to measure and record the 3-hour average pressure...
33 CFR 149.414 - What are the requirements for a fire detection and alarm system?
Code of Federal Regulations, 2011 CFR
2011-07-01
... national consensus standard, as that term is defined in 29 CFR 1910.2, for fire detection and fire alarm... fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... EQUIPMENT Firefighting and Fire Protection Equipment Firefighting Requirements § 149.414 What are the...
33 CFR 149.414 - What are the requirements for a fire detection and alarm system?
Code of Federal Regulations, 2013 CFR
2013-07-01
... national consensus standard, as that term is defined in 29 CFR 1910.2, for fire detection and fire alarm... fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... EQUIPMENT Firefighting and Fire Protection Equipment Firefighting Requirements § 149.414 What are the...
33 CFR 149.414 - What are the requirements for a fire detection and alarm system?
Code of Federal Regulations, 2012 CFR
2012-07-01
... national consensus standard, as that term is defined in 29 CFR 1910.2, for fire detection and fire alarm... fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... EQUIPMENT Firefighting and Fire Protection Equipment Firefighting Requirements § 149.414 What are the...
33 CFR 149.414 - What are the requirements for a fire detection and alarm system?
Code of Federal Regulations, 2014 CFR
2014-07-01
... national consensus standard, as that term is defined in 29 CFR 1910.2, for fire detection and fire alarm... fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... EQUIPMENT Firefighting and Fire Protection Equipment Firefighting Requirements § 149.414 What are the...
Increasing smoke alarm operability through theory-based health education: a randomised trial.
Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S
2014-12-01
Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm's hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005-2008. Follow-up visits checked alarm operability in 370 homes (85%) 1-3.5 years after installation. number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. http://www.clinicaltrials.gov number NCT00139126. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Joshi, Rohan; Mortel, Heidi van de; Feijs, Loe; Andriessen, Peter; Pul, Carola van
2017-01-01
Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient's room within the 90s of the alarm being generated. Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20-52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21-1.78; <0.001) while that of responding to a ventilator alarm was lower at 0.35 (95% CI = 0.27-0.46; p <0.001). For every 20s increase in the duration of an alarm, the odds of responding to the alarm (within 90s) increased to 1.15 (95% CI = 1.1-1.2; p <0.001). The random effect per infant improved the fit of the model to the data with the response times being slower for infants suffering from chronic illnesses while being faster for infants who were clinically unstable. Even though nurses respond to only a fraction of all critical alarms, they consider the vast majority of critical and yellow alarms as useful and relevant. When notified of a critical alarm, they seek waveform information and employ heuristics in determining whether or not to respond to the alarm. Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms.
van de Mortel, Heidi; Feijs, Loe; Andriessen, Peter; van Pul, Carola
2017-01-01
Aim Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. Methods The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient’s room within the 90s of the alarm being generated. Results Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20–52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21–1.78; <0.001) while that of responding to a ventilator alarm was lower at 0.35 (95% CI = 0.27–0.46; p <0.001). For every 20s increase in the duration of an alarm, the odds of responding to the alarm (within 90s) increased to 1.15 (95% CI = 1.1–1.2; p <0.001). The random effect per infant improved the fit of the model to the data with the response times being slower for infants suffering from chronic illnesses while being faster for infants who were clinically unstable. Discussion Even though nurses respond to only a fraction of all critical alarms, they consider the vast majority of critical and yellow alarms as useful and relevant. When notified of a critical alarm, they seek waveform information and employ heuristics in determining whether or not to respond to the alarm. Conclusion Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms. PMID:28981515
Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.
McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George
2016-07-01
The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.
Integrating physically based simulators with Event Detection Systems: Multi-site detection approach.
Housh, Mashor; Ohar, Ziv
2017-03-01
The Fault Detection (FD) Problem in control theory concerns of monitoring a system to identify when a fault has occurred. Two approaches can be distinguished for the FD: Signal processing based FD and Model-based FD. The former concerns of developing algorithms to directly infer faults from sensors' readings, while the latter uses a simulation model of the real-system to analyze the discrepancy between sensors' readings and expected values from the simulation model. Most contamination Event Detection Systems (EDSs) for water distribution systems have followed the signal processing based FD, which relies on analyzing the signals from monitoring stations independently of each other, rather than evaluating all stations simultaneously within an integrated network. In this study, we show that a model-based EDS which utilizes a physically based water quality and hydraulics simulation models, can outperform the signal processing based EDS. We also show that the model-based EDS can facilitate the development of a Multi-Site EDS (MSEDS), which analyzes the data from all the monitoring stations simultaneously within an integrated network. The advantage of the joint analysis in the MSEDS is expressed by increased detection accuracy (higher true positive alarms and fewer false alarms) and shorter detection time. Copyright © 2016 Elsevier Ltd. All rights reserved.
46 CFR 129.570 - Overfill protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... alarm system or failure of electrical circuitry to the tank level sensor; and (3) Be able to be checked... that monitors the condition of the alarm circuitry and sensor. (d) The high-level alarm required by...
46 CFR 119.530 - Bilge high level alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge high level alarms. 119.530 Section 119.530... Bilge and Ballast Systems § 119.530 Bilge high level alarms. (a) Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following...
The design of remote temperature monitoring system
NASA Astrophysics Data System (ADS)
Li, Biqing; Li, Zhao; Wei, Liuren
2017-08-01
This design is made on the basis of the single-chip microcomputer remote temperature monitoring system. STC89C51RC is the main core part, this design use the sensor DHT11 of temperature or humidity and wireless transceiver NRF24L01 the temperature of the test site for long-range wireless measurement and monitoring. The design contains the main system and the small system, of which the main system can show the actual test site temperature and humidity values, voice broadcast, out of control and receive data alarm function; The small system has the function of temperature and humidity, temperature monitoring and sending data. After debugging, the user customizable alarm upper and lower temperature, when the temperature exceeds limit value, the main system of buzzer alarm immediately. The system has simple structure, complete functions and can alarm in time, it can be widely used remote temperature acquisition and monitoring of the site.
User acceptance of intelligent avionics: A study of automatic-aided target recognition
NASA Technical Reports Server (NTRS)
Becker, Curtis A.; Hayes, Brian C.; Gorman, Patrick C.
1991-01-01
User acceptance of new support systems typically was evaluated after the systems were specified, designed, and built. The current study attempts to assess user acceptance of an Automatic-Aided Target Recognition (ATR) system using an emulation of such a proposed system. The detection accuracy and false alarm level of the ATR system were varied systematically, and subjects rated the tactical value of systems exhibiting different performance levels. Both detection accuracy and false alarm level affected the subjects' ratings. The data from two experiments suggest a cut-off point in ATR performance below which the subjects saw little tactical value in the system. An ATR system seems to have obvious tactical value only if it functions at a correct detection rate of 0.7 or better with a false alarm level of 0.167 false alarms per square degree or fewer.
A personalized health-monitoring system for elderly by combining rules and case-based reasoning.
Ahmed, Mobyen Uddin
2015-01-01
Health-monitoring system for elderly in home environment is a promising solution to provide efficient medical services that increasingly interest by the researchers within this area. It is often more challenging when the system is self-served and functioning as personalized provision. This paper proposed a personalized self-served health-monitoring system for elderly in home environment by combining general rules with a case-based reasoning approach. Here, the system generates feedback, recommendation and alarm in a personalized manner based on elderly's medical information and health parameters such as blood pressure, blood glucose, weight, activity, pulse, etc. A set of general rules has used to classify individual health parameters. The case-based reasoning approach is used to combine all different health parameters, which generates an overall classification of health condition. According to the evaluation result considering 323 cases and k=2 i.e., top 2 most similar retrieved cases, the sensitivity, specificity and overall accuracy are achieved as 90%, 97% and 96% respectively. The preliminary result of the system is acceptable since the feedback; recommendation and alarm messages are personalized and differ from the general messages. Thus, this approach could be possibly adapted for other situations in personalized elderly monitoring.
Sequence and batch language programs and alarm related C Programs for the 242-A MCS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, J.F.
1996-04-15
A Distributive Process Control system was purchased by Project B-534, 242-A Evaporator/Crystallizer Upgrades. This control system, called the Monitor and Control system (MCS), was installed in the 242-A evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict themore » overall process. To do this, WTSE developed a second alarm scheme.« less
Stand-alone tsunami alarm equipment
NASA Astrophysics Data System (ADS)
Katsumata, Akio; Hayashi, Yutaka; Miyaoka, Kazuki; Tsushima, Hiroaki; Baba, Toshitaka; Catalán, Patricio A.; Zelaya, Cecilia; Riquelme Vasquez, Felipe; Sanchez-Olavarria, Rodrigo; Barrientos, Sergio
2017-05-01
One of the quickest means of tsunami evacuation is transfer to higher ground soon after strong and long ground shaking. Ground shaking itself is a good initiator of the evacuation from disastrous tsunami. Longer period seismic waves are considered to be more correlated with the earthquake magnitude. We investigated the possible application of this to tsunami hazard alarm using single-site ground motion observation. Information from the mass media is sometimes unavailable due to power failure soon after a large earthquake. Even when an official alarm is available, multiple information sources of tsunami alert would help people become aware of the coming risk of a tsunami. Thus, a device that indicates risk of a tsunami without requiring other data would be helpful to those who should evacuate. Since the sensitivity of a low-cost MEMS (microelectromechanical systems) accelerometer is sufficient for this purpose, tsunami alarm equipment for home use may be easily realized. Amplitude of long-period (20 s cutoff) displacement was proposed as the threshold for the alarm based on empirical relationships among magnitude, tsunami height, hypocentral distance, and peak ground displacement of seismic waves. Application of this method to recent major earthquakes indicated that such equipment could effectively alert people to the possibility of tsunami.
Cognitive Radios Exploiting Gray Spaces via Compressed Sensing
NASA Astrophysics Data System (ADS)
Wieruch, Dennis; Jung, Peter; Wirth, Thomas; Dekorsy, Armin; Haustein, Thomas
2016-07-01
We suggest an interweave cognitive radio system with a gray space detector, which is properly identifying a small fraction of unused resources within an active band of a primary user system like 3GPP LTE. Therefore, the gray space detector can cope with frequency fading holes and distinguish them from inactive resources. Different approaches of the gray space detector are investigated, the conventional reduced-rank least squares method as well as the compressed sensing-based orthogonal matching pursuit and basis pursuit denoising algorithm. In addition, the gray space detector is compared with the classical energy detector. Simulation results present the receiver operating characteristic at several SNRs and the detection performance over further aspects like base station system load for practical false alarm rates. The results show, that especially for practical false alarm rates the compressed sensing algorithm are more suitable than the classical energy detector and reduced-rank least squares approach.
NASA Astrophysics Data System (ADS)
Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara
2015-07-01
We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.
33 CFR 149.414 - What are the requirements for a fire detection and alarm system?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the requirements for a fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... national consensus standard, as that term is defined in 29 CFR 1910.2, for fire detection and fire alarm...
[Digital acoustic burglar alarm system using infrared radio remote control].
Wang, Song-De; Zhao, Yan; Yao, Li-Ping; Zhang, Shuan-Ji
2009-03-01
Using butt emission infrared sensors, radio receiving and sending modules, double function integrated circuit with code and code translation, LED etc, a digital acoustic burglar alarm system using infrared radio to realize remote control was designed. It uses infrared ray invisible to eyes, composing area of radio distance. Once people and objects shelter the infrared ray, a testing signal will be output by the tester, and the sender will be triggered to work. The radio coding signal that sender sent is received by the receiver, then processed by a serial circuit. The control signal is output to trigger the sounder to give out an alarm signal, and the operator will be cued to notice this variation. At the same time, the digital display will be lighted and the alarm place will be watched. Digital coding technology is used, and a number of sub alarm circuits can joint the main receiver, so a lot of places can be monitored. The whole system features a module structure, with the property of easy alignment, stable operation, debug free and so on. The system offers an alarm range reaching 1 000 meters in all directions, and can be widely used in family, shop, storehouse, orchard and so on.
Detection of cat-eye effect echo based on unit APD
NASA Astrophysics Data System (ADS)
Wu, Dong-Sheng; Zhang, Peng; Hu, Wen-Gang; Ying, Jia-Ju; Liu, Jie
2016-10-01
The cat-eye effect echo of optical system can be detected based on CCD, but the detection range is limited within several kilometers. In order to achieve long-range even ultra-long-range detection, it ought to select APD as detector because of the high sensitivity of APD. The detection system of cat-eye effect echo based on unit APD is designed in paper. The implementation scheme and key technology of the detection system is presented. The detection performances of the detection system including detection range, detection probability and false alarm probability are modeled. Based on the model, the performances of the detection system are analyzed using typical parameters. The results of numerical calculation show that the echo signal-to-noise ratio is greater than six, the detection probability is greater than 99.9% and the false alarm probability is less tan 0.1% within 20 km detection range. In order to verify the detection effect, we built the experimental platform of detection system according to the design scheme and carry out the field experiments. The experimental results agree well with the results of numerical calculation, which prove that the detection system based on the unit APD is feasible to realize remote detection for cat-eye effect echo.
NASA Astrophysics Data System (ADS)
Havens, Timothy C.; Spain, Christopher J.; Ho, K. C.; Keller, James M.; Ton, Tuan T.; Wong, David C.; Soumekh, Mehrdad
2010-04-01
Forward-looking ground-penetrating radar (FLGPR) has received a significant amount of attention for use in explosivehazards detection. A drawback to FLGPR is that it results in an excessive number of false detections. This paper presents our analysis of the explosive-hazards detection system tested by the U.S. Army Night Vision and Electronic Sensors Directorate (NVESD). The NVESD system combines an FLGPR with a visible-spectrum color camera. We present a target detection algorithm that uses a locally-adaptive detection scheme with spectrum-based features. The remaining FLGPR detections are then projected into the camera imagery and image-based features are collected. A one-class classifier is then used to reduce the number of false detections. We show that our proposed FLGPR target detection algorithm, coupled with our camera-based false alarm (FA) reduction method, is effective at reducing the number of FAs in test data collected at a US Army test facility.
A bioinspired collision detection algorithm for VLSI implementation
NASA Astrophysics Data System (ADS)
Cuadri, J.; Linan, G.; Stafford, R.; Keil, M. S.; Roca, E.
2005-06-01
In this paper a bioinspired algorithm for collision detection is proposed, based on previous models of the locust (Locusta migratoria) visual system reported by F.C. Rind and her group, in the University of Newcastle-upon-Tyne. The algorithm is suitable for VLSI implementation in standard CMOS technologies as a system-on-chip for automotive applications. The working principle of the algorithm is to process a video stream that represents the current scenario, and to fire an alarm whenever an object approaches on a collision course. Moreover, it establishes a scale of warning states, from no danger to collision alarm, depending on the activity detected in the current scenario. In the worst case, the minimum time before collision at which the model fires the collision alarm is 40 msec (1 frame before, at 25 frames per second). Since the average time to successfully fire an airbag system is 2 msec, even in the worst case, this algorithm would be very helpful to more efficiently arm the airbag system, or even take some kind of collision avoidance countermeasures. Furthermore, two additional modules have been included: a "Topological Feature Estimator" and an "Attention Focusing Algorithm". The former takes into account the shape of the approaching object to decide whether it is a person, a road line or a car. This helps to take more adequate countermeasures and to filter false alarms. The latter centres the processing power into the most active zones of the input frame, thus saving memory and processing time resources.
46 CFR 154.1810 - Cargo manual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... leakage. (4) The use of the firefighting systems on the vessel. (5) The features of the cargo containment... detection systems. (x) Alarm or safety indication systems. (xi) Cargo jettisoning system. (xii) The system...) A description of gas detection systems and alarm or safety systems. (15) A description of the...
Application of the PageRank Algorithm to Alarm Graphs
NASA Astrophysics Data System (ADS)
Treinen, James J.; Thurimella, Ramakrishna
The task of separating genuine attacks from false alarms in large intrusion detection infrastructures is extremely difficult. The number of alarms received in such environments can easily enter into the millions of alerts per day. The overwhelming noise created by these alarms can cause genuine attacks to go unnoticed. As means of highlighting these attacks, we introduce a host ranking technique utilizing Alarm Graphs. Rather than enumerate all potential attack paths as in Attack Graphs, we build and analyze graphs based on the alarms generated by the intrusion detection sensors installed on a network. Given that the alarms are predominantly false positives, the challenge is to identify, separate, and ideally predict future attacks. In this paper, we propose a novel approach to tackle this problem based on the PageRank algorithm. By elevating the rank of known attackers and victims we are able to observe the effect that these hosts have on the other nodes in the Alarm Graph. Using this information we are able to discover previously overlooked attacks, as well as defend against future intrusions.
Alarm guided critical function and success path monitoring
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
The use of alarm indication on the overview (IPSO) display to initiate diagnosis of challenges to critical functions or unavailability of success paths, and further alarm-based guidance toward ultimate diagnosis.
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2014 CFR
2014-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2013 CFR
2013-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2011 CFR
2011-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2012 CFR
2012-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
Passive intrusion detection system
NASA Technical Reports Server (NTRS)
Laue, E. G. (Inventor)
1980-01-01
An intrusion detection system is described in which crystal oscillators are used to provide a frequency which varies as a function of fluctuations of a particular environmental property of the atmosphere, e.g., humidity, in the protected volume. The system is based on the discovery that the frequency of an oscillator whose crystal is humidity sensitive, varies at a frequency or rate which is within a known frequency band, due to the entry of an intruder into the protected volume. The variable frequency is converted into a voltage which is then filtered by a filtering arrangement which permits only voltage variations at frequencies within the known frequency band to activate an alarm, while inhibiting the alarm activation when the voltage frequency is below or above the known frequency band.
8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), ...
8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), FROM ENTRYWAY, LOOKING NORTH, SHOWING ADDITIONAL 'GAMEWELL' FIRE ALARM SYSTEMS. - Oakland Naval Supply Center, Firehouse, East of Fourth Street, between A & B Streets, Oakland, Alameda County, CA
Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus).
Deng, Huaiqing; Gao, Kai; Zhou, Jiang
2016-09-30
Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002-2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7-10 min) followed by longer variable-frequency mobbing calls lasting 5-12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520-1000 Hz and 690-3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates' species. The system of vocal alarm behavior described in this critically endangered species is simple and effective.
Development of a Low Cost Earthquake Early Warning System in Taiwan
NASA Astrophysics Data System (ADS)
Wu, Y. M.
2017-12-01
The National Taiwan University (NTU) developed an earthquake early warning (EEW) system for research purposes using low-cost accelerometers (P-Alert) since 2010. As of 2017, a total of 650 stations have been deployed and configured. The NTU system can provide earthquake information within 15 s of an earthquake occurrence. Thus, this system may provide early warnings for cities located more than 50 km from the epicenter. Additionally, the NTU system also has an onsite alert function that triggers a warning for incoming P-waves greater than a certain magnitude threshold, thus providing a 2-3 s lead time before peak ground acceleration (PGA) for regions close to an epicenter. Detailed shaking maps are produced by the NTU system within one or two minutes after an earthquake. Recently, a new module named ShakeAlarm has been developed. Equipped with real-time acceleration signals and the time-dependent anisotropic attenuation relationship of the PGA, ShakingAlarm can provide an accurate PGA estimation immediately before the arrival of the observed PGA. This unique advantage produces sufficient lead time for hazard assessment and emergency response, which is unavailable for traditional shakemap, which are based on only the PGA observed in real time. The performance of ShakingAlarm was tested with six M > 5.5 inland earthquakes from 2013 to 2016. Taking the 2016 M6.4 Meinong earthquake simulation as an example, the predicted PGA converges to a stable value and produces a predicted shake map and an isocontour map of the predicted PGA within 16 seconds of earthquake occurrence. Compared with traditional regional EEW system, ShakingAlarm can effectively identify possible damage regions and provide valuable early warning information (magnitude and PGA) for risk mitigation.
Consequences of increasing convection onto patient care and protein removal in hemodialysis
Duranton, Flore; Guzman, Caroline; Szwarc, Ilan; Vetromile, Fernando; Cazevieille, Chantal; Brunet, Philippe; Servel, Marie-Françoise; Le Quintrec, Moglie
2017-01-01
Introduction Recent randomised controlled trials suggest that on-line hemodiafiltration (OL-HDF) improves survival, provided that it reaches high convective volumes. However, there is scant information on the feasibility and the consequences of modifying convection volumes in clinics. Methods Twelve stable dialysis patients were treated with high-flux 1.8 m2 polysulphone dialyzers and 4 levels of convection flows (QUF) based on GKD-UF monitoring of the system, for 1 week each. The consequences on dialysis delivery (transmembrane pressure (TMP), number of alarms, % of achieved prescribed convection) and efficacy (mass removal of low and high molecular weight compounds) were analysed. Results TMP increased exponentially with QUF (p<0.001 for N >56,000 monitoring values). Beyond 21 L/session, this resulted into frequent TMP alarms requiring nursing staff interventions (mean ± SEM: 10.3 ± 2.2 alarms per session, p<0.001 compared to lower convection volumes). Optimal convection volumes as assessed by GKD-UF-max were 20.6 ± 0.4 L/session, whilst 4 supplementary litres were obtained in the maximum situation (24.5 ± 0.6 L/session) but the proportion of sessions achieving the prescribed convection volume decreased from 94% to only 33% (p<0.001). Convection increased high molecular weight compound removal and shifted the membrane cut-off towards the higher molecular weight range. Conclusions Reaching high convection volumes as recommended by the recent RCTs (> 20L) is feasible by setting an HDF system at its optimal conditions based upon the GKD-UF monitoring. Prescribing higher convection volumes resulted in instability of the system, provoked alarms, was bothersome for the nursing staff and the patients, rarely achieved the prescribed convection volumes and increased removal of high molecular weight compounds, notably albumin. PMID:28166268
Consequences of increasing convection onto patient care and protein removal in hemodialysis.
Gayrard, Nathalie; Ficheux, Alain; Duranton, Flore; Guzman, Caroline; Szwarc, Ilan; Vetromile, Fernando; Cazevieille, Chantal; Brunet, Philippe; Servel, Marie-Françoise; Argilés, Àngel; Le Quintrec, Moglie
2017-01-01
Recent randomised controlled trials suggest that on-line hemodiafiltration (OL-HDF) improves survival, provided that it reaches high convective volumes. However, there is scant information on the feasibility and the consequences of modifying convection volumes in clinics. Twelve stable dialysis patients were treated with high-flux 1.8 m2 polysulphone dialyzers and 4 levels of convection flows (QUF) based on GKD-UF monitoring of the system, for 1 week each. The consequences on dialysis delivery (transmembrane pressure (TMP), number of alarms, % of achieved prescribed convection) and efficacy (mass removal of low and high molecular weight compounds) were analysed. TMP increased exponentially with QUF (p<0.001 for N >56,000 monitoring values). Beyond 21 L/session, this resulted into frequent TMP alarms requiring nursing staff interventions (mean ± SEM: 10.3 ± 2.2 alarms per session, p<0.001 compared to lower convection volumes). Optimal convection volumes as assessed by GKD-UF-max were 20.6 ± 0.4 L/session, whilst 4 supplementary litres were obtained in the maximum situation (24.5 ± 0.6 L/session) but the proportion of sessions achieving the prescribed convection volume decreased from 94% to only 33% (p<0.001). Convection increased high molecular weight compound removal and shifted the membrane cut-off towards the higher molecular weight range. Reaching high convection volumes as recommended by the recent RCTs (> 20L) is feasible by setting an HDF system at its optimal conditions based upon the GKD-UF monitoring. Prescribing higher convection volumes resulted in instability of the system, provoked alarms, was bothersome for the nursing staff and the patients, rarely achieved the prescribed convection volumes and increased removal of high molecular weight compounds, notably albumin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenfield, Bryce A.
2009-12-01
A detailed instructional manual was created to guide criticality safety engineers through the process of designing a criticality alarm system (CAS) for Department of Energy (DOE) hazard class 1 and 2 facilities. Regulatory and technical requirements were both addressed. A list of design tasks and technical subtasks are thoroughly analyzed to provide concise direction for how to complete the analysis. An example of the application of the design methodology, the Criticality Alarm System developed for the Radioisotope Production Laboratory (RPL) of Richland, Washington is also included. The analysis for RPL utilizes the Monte Carlo code MCNP5 for establishing detector coveragemore » in the facility. Significant improvements to the existing CAS were made that increase the reliability, transparency, and coverage of the system.« less
A State-Space Approach to Optimal Level-Crossing Prediction for Linear Gaussian Processes
NASA Technical Reports Server (NTRS)
Martin, Rodney Alexander
2009-01-01
In many complex engineered systems, the ability to give an alarm prior to impending critical events is of great importance. These critical events may have varying degrees of severity, and in fact they may occur during normal system operation. In this article, we investigate approximations to theoretically optimal methods of designing alarm systems for the prediction of level-crossings by a zero-mean stationary linear dynamic system driven by Gaussian noise. An optimal alarm system is designed to elicit the fewest false alarms for a fixed detection probability. This work introduces the use of Kalman filtering in tandem with the optimal level-crossing problem. It is shown that there is a negligible loss in overall accuracy when using approximations to the theoretically optimal predictor, at the advantage of greatly reduced computational complexity. I
Benefit of an electronic medical record-based alarm in the optimization of stress ulcer prophylaxis.
Saad, Emanuel José; Bedini, Marianela; Becerra, Ana Florencia; Martini, Gustavo Daniel; Gonzalez, Jacqueline Griselda; Bolomo, Andrea; Castellani, Luciana; Quiroga, Silvana; Morales, Cristian; Leathers, James; Balderramo, Domingo; Albertini, Ricardo Arturo
2018-06-09
The use of stress ulcer prophylaxis (SUP) has risen in recent years, even in patients without a clear indication for therapy. To evaluate the efficacy of an electronic medical record (EMR)-based alarm to improve appropriate SUP use in hospitalized patients. We conducted an uncontrolled before-after study comparing SUP prescription in intensive care unit (ICU) patients and non-ICU patients, before and after the implementation of an EMR-based alarm that provided the correct indications for SUP. 1627 patients in the pre-intervention and 1513 patients in the post-intervention cohorts were included. The EMR-based alarm improved appropriate (49.6% vs. 66.6%, p<0.001) and reduced inappropriate SUP use (50.4% vs. 33.3%, p<0.001) in ICU patients only. These differences were related to the optimization of SUP in low risk patients. There was no difference in overt gastrointestinal bleeding between the two cohorts. Unjustified costs related to SUP were reduced by a third after EMR-based alarm use. The use of an EMR-based alarm improved appropriate and reduced inappropriate use of SUP in ICU patients. This benefit was limited to optimization in low risk patients and associated with a decrease in SUP costs. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.
Ultrasonic Technology in Duress Alarms.
ERIC Educational Resources Information Center
Lee, Martha A.
2000-01-01
Provides the pros and cons of the most commonly used technologies in personal duress alarm systems in the school environment. Discussed are radio frequency devices, infrared systems, and ultrasonic technology. (GR)
Nurses' Perceptions and Practices Related to Alarm Management: A Quality Improvement Initiative.
Cameron, Hannah L; Little, Barbara
2018-05-01
The purpose of this quality improvement project was to develop, implement, and assess the effects of an alarm management policy and educational program on nurses' perceptions and practices of alarm management in an acute care hospital. Nurses from an acute care hospital in the southeastern United States attended a mandatory alarm management education program. The hospital implemented the evidence-based alarm management education to achieve the NPSG.06.01.01: Alarm Management. Pre- and posttests were administered to evaluate the education and the changes in nurses' perceptions and practices of clinical alarms. A total of 417 nurses received the educational intervention. All participants completed the pretest, and 215 (51%) completed the voluntary posttest. Significant improvements were made in alarm perceptions and practices. Nurses suggested unit-specific alarm education, improved staffing, and updated equipment. Findings support the benefits of continued education in alarm management for nurses. Bedside nurses are a critical member of a multidisciplinary alarm management team because they are at the forefront of patient safety and most at risk for experiencing alarm fatigue. J Contin Educ Nurs. 2018;49(5):207-215. Copyright 2018, SLACK Incorporated.
On the Use of Low-Cost Radar Networks for Collision Warning Systems Aboard Dumpers
González-Partida, José-Tomás; León-Infante, Francisco; Blázquez-García, Rodrigo; Burgos-García, Mateo
2014-01-01
The use of dumpers is one of the main causes of accidents in construction sites, many of them with fatal consequences. These kinds of work machines have many blind angles that complicate the driving task due to their large size and volume. To guarantee safety conditions is necessary to use automatic aid systems that can detect and locate the different objects and people in a work area. One promising solution is a radar network based on low-cost radar transceivers aboard the dumper. The complete system is specified to operate with a very low false alarm rate to avoid unnecessary stops of the dumper that reduce its productivity. The main sources of false alarm are the heavy ground clutter, and the interferences between the radars of the network. This article analyses the clutter for LFM signaling and proposes the use of Offset Linear Frequency Modulated Continuous Wave (OLFM-CW) as radar signal. This kind of waveform can be optimized to reject clutter and self-interferences. Jointly, a data fusion chain could be used to reduce the false alarm rate of the complete radar network. A real experiment is shown to demonstrate the feasibility of the proposed system. PMID:24577521
On the use of low-cost radar networks for collision warning systems aboard dumpers.
González-Partida, José-Tomás; León-Infante, Francisco; Blázquez-García, Rodrigo; Burgos-García, Mateo
2014-02-26
The use of dumpers is one of the main causes of accidents in construction sites, many of them with fatal consequences. These kinds of work machines have many blind angles that complicate the driving task due to their large size and volume. To guarantee safety conditions is necessary to use automatic aid systems that can detect and locate the different objects and people in a work area. One promising solution is a radar network based on low-cost radar transceivers aboard the dumper. The complete system is specified to operate with a very low false alarm rate to avoid unnecessary stops of the dumper that reduce its productivity. The main sources of false alarm are the heavy ground clutter, and the interferences between the radars of the network. This article analyses the clutter for LFM signaling and proposes the use of Offset Linear Frequency Modulated Continuous Wave (OLFM-CW) as radar signal. This kind of waveform can be optimized to reject clutter and self-interferences. Jointly, a data fusion chain could be used to reduce the false alarm rate of the complete radar network. A real experiment is shown to demonstrate the feasibility of the proposed system.
Analysis and design of the ultraviolet warning optical system based on interference imaging
NASA Astrophysics Data System (ADS)
Wang, Wen-cong; Hu, Hui-jun; Jin, Dong-dong; Chu, Xin-bo; Shi, Yu-feng; Song, Juan; Liu, Jin-sheng; Xiao, Ting; Shao, Si-pei
2017-10-01
Ultraviolet warning technology is one of the important methods for missile warning. It provides a very effective way to detect the target for missile approaching alarm. With the development of modern technology, especially the development of information technology at high speed, the ultraviolet early warning system plays an increasingly important role. Compared to infrared warning, the ultraviolet warning has high efficiency and low false alarm rate. In the modern warfare, how to detect the threats earlier, prevent and reduce the attack of precision-guided missile has become a new challenge of missile warning technology. Because the ultraviolet warning technology has high environmental adaptability, the low false alarm rate, small volume and other advantages, in the military field applications it has been developed rapidly. For the ultraviolet warning system, the optimal working waveband is 250 nm 280 nm (Solar Blind UV) due to the strong absorption of ozone layer. According to current application demands for solar blind ultraviolet detection and warning, this paper proposes ultraviolet warning optical system based on interference imaging, which covers solar blind ultraviolet (250nm-280nm) and dual field. This structure includes a primary optical system, an ultraviolet reflector array, an ultraviolet imaging system and an ultraviolet interference imaging system. It makes use of an ultraviolet beam-splitter to achieve the separation of two optical systems. According to the detector and the corresponding application needs of two visual field of the optical system, the calculation and optical system design were completed. After the design, the MTF of the two optical system is more than 0.8@39lp/mm.A single pixel energy concentration is greater than 80%.
Low Power Wireless Smoke Alarm System in Home Fires
Luis, Juan Aponte; Galán, Juan Antonio Gómez; Espigado, Javier Alcina
2015-01-01
A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects. PMID:26307994
Low Power Wireless Smoke Alarm System in Home Fires.
Aponte Luis, Juan; Gómez Galán, Juan Antonio; Alcina Espigado, Javier
2015-08-21
A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects.
Fire Protection. Honeywell Planning Guide.
ERIC Educational Resources Information Center
Honeywell, Inc., Minneapolis, Minn.
A general discussion of fire alarms and protection is provided by a manufacturer of automated monitoring and control systems. Background information describes old and new fire alarm systems, comparing system components, wage savings, and cost analysis. Different kinds of automatic systems are listed, including--(1) local system, (2) auxiliary…
Accident diagnosis system based on real-time decision tree expert system
NASA Astrophysics Data System (ADS)
Nicolau, Andressa dos S.; Augusto, João P. da S. C.; Schirru, Roberto
2017-06-01
Safety is one of the most studied topics when referring to power stations. For that reason, sensors and alarms develop an important role in environmental and human protection. When abnormal event happens, it triggers a chain of alarms that must be, somehow, checked by the control room operators. In this case, diagnosis support system can help operators to accurately identify the possible root-cause of the problem in short time. In this article, we present a computational model of a generic diagnose support system based on artificial intelligence, that was applied on the dataset of two real power stations: Angra1 Nuclear Power Plant and Santo Antônio Hydroelectric Plant. The proposed system processes all the information logged in the sequence of events before a shutdown signal using the expert's knowledge inputted into an expert system indicating the chain of events, from the shutdown signal to its root-cause. The results of both applications showed that the support system is a potential tool to help the control room operators identify abnormal events, as accidents and consequently increase the safety.
Görges, Matthias; West, Nicholas C; Christopher, Nancy A; Koch, Jennifer L; Brodie, Sonia M; Lowlaavar, Nasim; Lauder, Gillian R; Ansermino, J Mark
2016-04-01
Respiratory depression in children receiving postoperative opioid infusions is a significant risk because of the interindividual variability in analgesic requirement. Detection of respiratory depression (or apnea) in these children may be improved with the introduction of automated acoustic respiratory rate (RR) monitoring. However, early detection of adverse events must be balanced with the risk of alarm fatigue. Our objective was to evaluate the use of acoustic RR monitoring in children receiving opioid infusions on a postsurgical ward and identify the causes of false alarm and optimal alarm thresholds. A video ethnographic study was performed using an observational, mixed methods approach. After surgery, an acoustic RR sensor was placed on the participant's neck and attached to a Rad87 monitor. The monitor was networked with paging for alarms. Vital signs data and paging notification logs were obtained from the central monitoring system. Webcam videos of the participant, infusion pump, and Rad87 monitor were recorded, stored on a secure server, and subsequently analyzed by 2 research nurses to identify the cause of the alarm, response, and effectiveness. Alarms occurring within a 90-second window were grouped into a single-alarm response opportunity. Data from 49 patients (30 females) with median age 14 (range, 4.4-18.8) years were analyzed. The 896 bedside vital sign threshold alarms resulted in 160 alarm response opportunities (44 low RR, 74 high RR, and 42 low SpO2). In 141 periods (88% of total), for which video was available, 65% of alarms were deemed effective (followed by an alarm-related action within 10 minutes). Nurses were the sole responders in 55% of effective alarms and the patient or parent in 20%. Episodes of desaturation (SpO2 < 90%) were observed in 9 patients: At the time of the SpO2 paging trigger, the RR was >10 bpm in 6 of 9 patients. Based on all RR samples observed, the default alarm thresholds, to serve as a starting point for each patient, would be a low RR of 6 (>10 years of age) and 10 (4-9 years of age). In this study, the use of RR monitoring did not improve the detection of respiratory depression. An RR threshold, which would have been predictive of desaturations, would have resulted in an unacceptably high false alarm rate. Future research using a combination of variables (e.g., SpO2 and RR), or the measurement of tidal volumes, may be needed to improve patient safety in the postoperative ward.
Remote monitoring and security alert based on motion detection using mobile
NASA Astrophysics Data System (ADS)
Suganya Devi, K.; Srinivasan, P.
2016-03-01
Background model does not have any robust solution and constitutes one of the main problems in surveillance systems. The aim of the paper is to provide a mobile based security to a remote monitoring system through a WAP using GSM modem. It is most designed to provide durability and versatility for a wide variety of indoor and outdoor applications. It is compatible with both narrow and band networks and provides simultaneous image detection. The communicator provides remote control, event driven recording, including pre-alarm and post-alarm and image motion detection. The web cam allowing them to be mounted either to a ceiling or wall without requiring bracket, with the use of web cam. We could continuously monitoring status in the client system through the web. If any intruder arrives in the client system, server will provide an alert to the mobile (what we are set in the message that message send to the authorized person) and the client can view the image using WAP.
Analysis of a SCADA System Anomaly Detection Model Based on Information Entropy
2014-03-27
20 Intrusion Detection...alarms ( Rem ). ............................................................................................................. 86 Figure 25. TP% for...literature concerning the focus areas of this research. The focus areas include SCADA vulnerabilities, information theory, and intrusion detection
A cost effective FBG-based security fence with fire alarm function
NASA Astrophysics Data System (ADS)
Wu, H. J.; Li, S. S.; Lu, X. L.; Wu, Y.; Rao, Y. J.
2012-02-01
Fiber Bragg Grating (FBG) is sensitive to the temperature as well when it is measuring the strain change, which is always avoided in most measurement applications. However, in this paper strain/temperature dual sensitivity is utilized to construct a special security fence with a second function of fire threat prediction. In an FBG-based fiber fence configuration, only by characteristics analysis and identification method, it can intelligently distinguish the different effects of personal threats and fires from their different trends of the wavelength drifts. Thus without any additional temperature sensing fittings or other fire alarm systems integrated, a normal perimeter security system can possess a second function of fire prediction, which can not only monitor the intrusion induced by personal actions but also predict fire threats in advance. The experimental results show the effectiveness of the method.
A Fault Alarm and Diagnosis Method Based on Sensitive Parameters and Support Vector Machine
NASA Astrophysics Data System (ADS)
Zhang, Jinjie; Yao, Ziyun; Lv, Zhiquan; Zhu, Qunxiong; Xu, Fengtian; Jiang, Zhinong
2015-08-01
Study on the extraction of fault feature and the diagnostic technique of reciprocating compressor is one of the hot research topics in the field of reciprocating machinery fault diagnosis at present. A large number of feature extraction and classification methods have been widely applied in the related research, but the practical fault alarm and the accuracy of diagnosis have not been effectively improved. Developing feature extraction and classification methods to meet the requirements of typical fault alarm and automatic diagnosis in practical engineering is urgent task. The typical mechanical faults of reciprocating compressor are presented in the paper, and the existing data of online monitoring system is used to extract fault feature parameters within 15 types in total; the inner sensitive connection between faults and the feature parameters has been made clear by using the distance evaluation technique, also sensitive characteristic parameters of different faults have been obtained. On this basis, a method based on fault feature parameters and support vector machine (SVM) is developed, which will be applied to practical fault diagnosis. A better ability of early fault warning has been proved by the experiment and the practical fault cases. Automatic classification by using the SVM to the data of fault alarm has obtained better diagnostic accuracy.
Designing a SCADA system simulator for fast breeder reactor
NASA Astrophysics Data System (ADS)
Nugraha, E.; Abdullah, A. G.; Hakim, D. L.
2016-04-01
SCADA (Supervisory Control and Data Acquisition) system simulator is a Human Machine Interface-based software that is able to visualize the process of a plant. This study describes the results of the process of designing a SCADA system simulator that aims to facilitate the operator in monitoring, controlling, handling the alarm, accessing historical data and historical trend in Nuclear Power Plant (NPP) type Fast Breeder Reactor (FBR). This research used simulation to simulate NPP type FBR Kalpakkam in India. This simulator was developed using Wonderware Intouch software 10 and is equipped with main menu, plant overview, area graphics, control display, set point display, alarm system, real-time trending, historical trending and security system. This simulator can properly simulate the principle of energy flow and energy conversion process on NPP type FBR. This SCADA system simulator can be used as training media for NPP type FBR prospective operators.
Cammaerts, Marie-Claire
2014-01-01
Abstract Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants’ ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. PMID:25525102
46 CFR 130.450 - Machinery alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms. (a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
2015-04-17
Software that runs on smartphones and desktop web browsers and notifies border officials of radiation alarms. It displays images and data associated with an alarm and provides a variety of reports. DOE had a need for discrete notification. PAS replaces the lights and sounds of a Radiation Portal Monitor.
2003-01-01
AFRL-IF-RS-TR-2002-315 Final Technical Report January 2003 THE EMERALD MISSION-BASED CORRELATION SYSTEM – AN EXPERIMENTAL DATA...2003 3. REPORT TYPE AND DATES COVERED Final Jan 02 – Jul 02 4. TITLE AND SUBTITLE THE EMERALD MISSION-BASED CORRELATION SYSTEM – AN EXPERIMENTAL...DISTRIBUTION CODE 13. ABSTRACT (Maximum 200 Words) This project was established to experiment on the efficacy of the SRI EMERALD Mission-based
Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus)
Deng, Huaiqing; Gao, Kai; Zhou, Jiang
2016-01-01
Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002–2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7–10 min) followed by longer variable-frequency mobbing calls lasting 5–12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520–1000 Hz and 690–3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates’ species. The system of vocal alarm behavior described in this critically endangered species is simple and effective. PMID:27686623
Schel, Anne Marijke; Tranquilli, Sandra; Zuberbühler, Klaus
2009-05-01
Vervet monkey alarm calling has long been the paradigmatic example of how primates use vocalizations in response to predators. In vervets, there is a close and direct relationship between the production of distinct alarm vocalizations and the presence of distinct predator types. Recent fieldwork has however revealed the use of several additional alarm calling systems in primates. Here, the authors describe playback studies on the alarm call system of two colobine species, the King colobus (Colobus polykomos) of Taï Forest, Ivory Coast, and the Guereza colobus (C. guereza) of Budongo Forest, Uganda. Both species produce two basic alarm call types, snorts and acoustically variable roaring phrases, when confronted with leopards or crowned eagles. Neither call type is given exclusively to one predator, but the authors found strong regularities in call sequencing. Leopards typically elicited sequences consisting of a snort followed by few phrases, while eagles typically elicited sequences with no snorts and many phrases. The authors discuss how these call sequences have the potential to encode information at different levels, such as predator type, response-urgency, or the caller's imminent behavior. (PsycINFO Database Record (c) 2009 APA, all rights reserved).
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-5 Zoning. (a) The zoning of the manual alarm system shall meet the same requirements as for the electric fire detecting system, § 76.27-5. (b) [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-5 Zoning. (a) The zoning of the manual alarm system shall meet the same requirements as for the electric fire detecting system, § 76.27-5. (b) [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-5 Zoning. (a) The zoning of the manual alarm system shall meet the same requirements as for the electric fire detecting system, § 76.27-5. (b) [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-5 Zoning. (a) The zoning of the manual alarm system shall meet the same requirements as for the electric fire detecting system, § 76.27-5. (b) [Reserved] ...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-5 Zoning. (a) The zoning of the manual alarm system shall meet the same requirements as for the electric fire detecting system, § 76.27-5. (b) [Reserved] ...
Fire protection for launch facilities using machine vision fire detection
NASA Astrophysics Data System (ADS)
Schwartz, Douglas B.
1993-02-01
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
Fire protection for launch facilities using machine vision fire detection
NASA Technical Reports Server (NTRS)
Schwartz, Douglas B.
1993-01-01
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
Very long apnea events in preterm infants
Vergales, Brooke D.; Lee, Hoshik; Clark, Matthew T.; Lake, Douglas E.; Mennen, Anne C.; Kattwinkel, John; Sinkin, Robert A.; Moorman, J. Randall; Fairchild, Karen D.; Delos, John B.
2014-01-01
Apnea is nearly universal among very low birth weight (VLBW) infants, and the associated bradycardia and desaturation may have detrimental consequences. We describe here very long (>60 s) central apnea events (VLAs) with bradycardia and desaturation, discovered using a computerized detection system applied to our database of over 100 infant years of electronic signals. Eighty-six VLAs occurred in 29 out of 335 VLBW infants. Eighteen of the 29 infants had a clinical event or condition possibly related to the VLA. Most VLAs occurred while infants were on nasal continuous positive airway pressure, supplemental oxygen, and caffeine. Apnea alarms on the bedside monitor activated in 66% of events, on average 28 s after cessation of breathing. Bradycardia alarms activated late, on average 64 s after cessation of breathing. Before VLAs oxygen saturation was unusually high, and during VLAs oxygen saturation and heart rate fell unusually slowly. We give measures of the relative severity of VLAs and theoretical calculations that describe the rate of decrease of oxygen saturation. A clinical conclusion is that very long apnea (VLA) events with bradycardia and desaturation are not rare. Apnea alarms failed to activate for about one-third of VLAs. It appears that neonatal intensive care unit (NICU) personnel respond quickly to bradycardia alarms but not consistently to apnea alarms. We speculate that more reliable apnea detection systems would improve patient safety in the NICU. A physiological conclusion is that the slow decrease of oxygen saturation is consistent with a physiological model based on assumed high values of initial oxygen saturation. PMID:25549762
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
An improved PCA method with application to boiler leak detection.
Sun, Xi; Marquez, Horacio J; Chen, Tongwen; Riaz, Muhammad
2005-07-01
Principal component analysis (PCA) is a popular fault detection technique. It has been widely used in process industries, especially in the chemical industry. In industrial applications, achieving a sensitive system capable of detecting incipient faults, which maintains the false alarm rate to a minimum, is a crucial issue. Although a lot of research has been focused on these issues for PCA-based fault detection and diagnosis methods, sensitivity of the fault detection scheme versus false alarm rate continues to be an important issue. In this paper, an improved PCA method is proposed to address this problem. In this method, a new data preprocessing scheme and a new fault detection scheme designed for Hotelling's T2 as well as the squared prediction error are developed. A dynamic PCA model is also developed for boiler leak detection. This new method is applied to boiler water/steam leak detection with real data from Syncrude Canada's utility plant in Fort McMurray, Canada. Our results demonstrate that the proposed method can effectively reduce false alarm rate, provide effective and correct leak alarms, and give early warning to operators.
46 CFR 189.55-5 - Plans and specifications required for new construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
... of the alarm and extinguishing systems, the fire extinguishers, means of access to different... dampers and the number identifying each system. (2) Ventilation diagram including dampers and other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains...
46 CFR 189.55-5 - Plans and specifications required for new construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to... other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains, carbon dioxide, clean agent, foam, and sprinkling systems. (e) Marine engineering. For...
46 CFR 189.55-5 - Plans and specifications required for new construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to... other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains, carbon dioxide, clean agent, foam, and sprinkling systems. (e) Marine engineering. For...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2012 CFR
2012-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2014 CFR
2014-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2011 CFR
2011-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2013 CFR
2013-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
32 CFR 223.7 - Procedures-determination of DoD UCNI.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Detection and Security Alarm Systems. (i) Information on the layout or design of security and alarm systems...) Frequency and schedule of DoD SNM inventories. (3) Facility Description. (i) Maps, conceptual design, and...
32 CFR 223.7 - Procedures-determination of DoD UCNI.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Detection and Security Alarm Systems. (i) Information on the layout or design of security and alarm systems...) Frequency and schedule of DoD SNM inventories. (3) Facility Description. (i) Maps, conceptual design, and...
18. DETAIL VIEW OF FIRE ALARM SYSTEM BOARD THAT LISTS ...
18. DETAIL VIEW OF FIRE ALARM SYSTEM BOARD THAT LISTS AREAS IN SHOPS COMPLEX. - Baltimore & Ohio Railroad, Mount Clare Shops, South side of Pratt Street between Carey & Poppleton Streets, Baltimore, Independent City, MD
Using GIS to evaluate a fire safety program in North Carolina.
Dudley, Thomas; Creppage, Kathleen; Shanahan, Meghan; Proescholdbell, Scott
2013-10-01
Evaluating program impact is a critical aspect of public health. Utilizing Geographic Information Systems (GIS) is a novel way to evaluate programs which try to reduce residential fire injuries and deaths. The purpose of this study is to demonstrate the application of GIS within the evaluation of a smoke alarm installation program in North Carolina. This approach incorporates national fire incident data which, when linked with program data, provides a clear depiction of the 10 years impact of the Get Alarmed, NC! program and estimates the number of potential lives saved. We overlapped Get Alarmed, NC! program installation data with national information on fires using GIS to identify homes that experienced a fire after an alarm was installed and calculated potential lives saved based on program documentation and average housing occupancy. We found that using GIS was an efficient and quick way to match addresses from two distinct sources. From this approach we estimated that between 221 and 384 residents were potentially saved due to alarms installed in their homes by Get Alarmed, NC!. Compared with other program evaluations that require intensive and costly participant telephone surveys and/or in-person interviews, the GIS approach is inexpensive, quick, and can easily analyze large disparate datasets. In addition, it can be used to help target the areas most at risk from the onset. These benefits suggest that by incorporating previously unutilized data, the GIS approach has the potential for broader applications within public health program evaluation.
Video performance for high security applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Connell, Jack C.; Norman, Bradley C.
2010-06-01
The complexity of physical protection systems has increased to address modern threats to national security and emerging commercial technologies. A key element of modern physical protection systems is the data presented to the human operator used for rapid determination of the cause of an alarm, whether false (e.g., caused by an animal, debris, etc.) or real (e.g., a human adversary). Alarm assessment, the human validation of a sensor alarm, primarily relies on imaging technologies and video systems. Developing measures of effectiveness (MOE) that drive the design or evaluation of a video system or technology becomes a challenge, given the subjectivitymore » of the application (e.g., alarm assessment). Sandia National Laboratories has conducted empirical analysis using field test data and mathematical models such as binomial distribution and Johnson target transfer functions to develop MOEs for video system technologies. Depending on the technology, the task of the security operator and the distance to the target, the Probability of Assessment (PAs) can be determined as a function of a variety of conditions or assumptions. PAs used as an MOE allows the systems engineer to conduct trade studies, make informed design decisions, or evaluate new higher-risk technologies. This paper outlines general video system design trade-offs, discusses ways video can be used to increase system performance and lists MOEs for video systems used in subjective applications such as alarm assessment.« less
Automated surveillance of 911 call data for detection of possible water contamination incidents.
Haas, Adam J; Gibbons, Darcy; Dangel, Chrissy; Allgeier, Steve
2011-03-30
Drinking water contamination, with the capability to affect large populations, poses a significant risk to public health. In recent water contamination events, the impact of contamination on public health appeared in data streams monitoring health-seeking behavior. While public health surveillance has traditionally focused on the detection of pathogens, developing methods for detection of illness from fast-acting chemicals has not been an emphasis. An automated surveillance system was implemented for Cincinnati's drinking water contamination warning system to monitor health-related 911 calls in the city of Cincinnati. Incident codes indicative of possible water contamination were filtered from all 911 calls for analysis. The 911 surveillance system uses a space-time scan statistic to detect potential water contamination incidents. The frequency and characteristics of the 911 alarms over a 2.5 year period were studied. During the evaluation, 85 alarms occurred, although most occurred prior to the implementation of an additional alerting constraint in May 2009. Data were available for analysis approximately 48 minutes after calls indicating alarms may be generated 1-2 hours after a rapid increase in call volume. Most alerts occurred in areas of high population density. The average alarm area was 9.22 square kilometers. The average number of cases in an alarm was nine calls. The 911 surveillance system provides timely notification of possible public health events, but did have limitations. While the alarms contained incident codes and location of the caller, additional information such as medical status was not available to assist validating the cause of the alarm. Furthermore, users indicated that a better understanding of 911 system functionality is necessary to understand how it would behave in an actual water contamination event.
Automated surveillance of 911 call data for detection of possible water contamination incidents
2011-01-01
Background Drinking water contamination, with the capability to affect large populations, poses a significant risk to public health. In recent water contamination events, the impact of contamination on public health appeared in data streams monitoring health-seeking behavior. While public health surveillance has traditionally focused on the detection of pathogens, developing methods for detection of illness from fast-acting chemicals has not been an emphasis. Methods An automated surveillance system was implemented for Cincinnati's drinking water contamination warning system to monitor health-related 911 calls in the city of Cincinnati. Incident codes indicative of possible water contamination were filtered from all 911 calls for analysis. The 911 surveillance system uses a space-time scan statistic to detect potential water contamination incidents. The frequency and characteristics of the 911 alarms over a 2.5 year period were studied. Results During the evaluation, 85 alarms occurred, although most occurred prior to the implementation of an additional alerting constraint in May 2009. Data were available for analysis approximately 48 minutes after calls indicating alarms may be generated 1-2 hours after a rapid increase in call volume. Most alerts occurred in areas of high population density. The average alarm area was 9.22 square kilometers. The average number of cases in an alarm was nine calls. Conclusions The 911 surveillance system provides timely notification of possible public health events, but did have limitations. While the alarms contained incident codes and location of the caller, additional information such as medical status was not available to assist validating the cause of the alarm. Furthermore, users indicated that a better understanding of 911 system functionality is necessary to understand how it would behave in an actual water contamination event. PMID:21450105
McCoy, Mary A; Roper, Carey; Campa, Emily; Stephens-Stidham, Shelli; Carlin, Debra K; Istre, Gregory R
2014-04-01
To assess the functionality of lithium-powered smoke alarms that had been installed through a community-based programme called Operation Installation (OI). A random sample was chosen of homes that had received smoke alarms through OI, 2, 4, 6, 8 and 10 years previously. Sampled homes were visited, and information collected included functional status of smoke alarms. For homes in the 6-, 8- and 10-year sample, smoke alarms were removed and tested for battery and alarm function. 800 homes were included in the survey results; 1884 smoke alarms had been installed through OI. The proportion of homes that had at least one functioning OI smoke alarm ranged from 91.8% for year 2 sample to 19.8% for year 10. Of the originally installed smoke alarms in year 10 sample, 45.5% had been removed and 59% (64/108) of those that were still installed were not functioning. Multivariate analysis showed that the presence of at least one working alarm in the home was associated positively with the number of smoke alarms that were originally installed and whether the original occupant was still living in the home, and negatively with the length of time since the smoke alarm was installed, and whether there was a smoker in the home. Testing of the smoke alarms revealed that most non-functioning alarms had missing or dead batteries. Less than a quarter of the originally installed smoke alarms were still present and functioning by year 10. These findings have important implications for smoke alarm installation programmes.
Roberts, Kristin J; Fowler, Erica; Comstock, R Dawn; Fernandez, Soledad; Abdel-Rasoul, Mahmoud; Mihalov, Leslie; Casavant, Marcel J; McKenzie, Lara B
2018-02-01
Although the proper installation and maintenance of carbon monoxide (CO) and smoke alarms can protect individuals from residential CO-related and fire-related injuries, these devices are underutilized. We describe characteristics associated with self-reported CO and smoke alarm use of parents recruited from a pediatric emergency department to improve CO alarm use. Parents of children ≤ 18 years (N = 299) reported socio-demographic characteristics and CO and smoke alarm ownership and practices. We assigned participants to a behavioral profile and a Precaution Adoption Process Model stage based on their self-reported CO and smoke alarm use. Most participants (71%) did not have CO alarms in their homes, but reported owning at least one working smoke alarm (98%). Participants who reported "perfect" CO alarm behavior (defined as having a working CO alarm, one near a sleeping area, with batteries replaced every 6 months; 9%) were more likely to earn a higher income, own their home, and have lived at their current residence for at least 2 years. Participants who reported "perfect" smoke alarm behavior (defined as having a working smoke alarm on every level, with batteries replaced every 6 months; 49%) were more likely to rent their home, receive federal assistance, and have lived at their current residence for at least 2 years. Interventions to increase correct CO alarm use are necessary.
Satellite Search and Rescue System Studies: Alarm and Position Reporting.
alarm and position reporting ( ALPR ) techniques, and the operational or planned spacecraft which might be available for piggybacking the ALPR payload...Several system concepts were then developed to perform the ALPR functions. The candidates were screened and the preferred system concepts were chosen
Code of Federal Regulations, 2011 CFR
2011-10-01
... Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) Spaces which are protected by a carbon... audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to... sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and the...
46 CFR 153.438 - Cargo pressure or temperature alarms required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Cargo pressure or temperature alarms required. 153.438... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a...
46 CFR 153.438 - Cargo pressure or temperature alarms required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Cargo pressure or temperature alarms required. 153.438... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a...
46 CFR 153.438 - Cargo pressure or temperature alarms required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Cargo pressure or temperature alarms required. 153.438... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a...
46 CFR 153.438 - Cargo pressure or temperature alarms required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pressure or temperature alarms required. 153.438... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a...
46 CFR 153.438 - Cargo pressure or temperature alarms required.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Cargo pressure or temperature alarms required. 153.438... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a...
46 CFR 63.25-7 - Exhaust gas boilers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... results in inadequate heat transfer, a high temperature alarm or low flow alarm must be activated. An... insufficient to ensure proper heat transfer. Additionally, an audible alarm must automatically sound, and a... water level, the control system must supply the feed water at a rate sufficient to ensure proper heat...
46 CFR 63.25-7 - Exhaust gas boilers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... results in inadequate heat transfer, a high temperature alarm or low flow alarm must be activated. An... insufficient to ensure proper heat transfer. Additionally, an audible alarm must automatically sound, and a... water level, the control system must supply the feed water at a rate sufficient to ensure proper heat...
Johnson, Kendall R; Hagadorn, James I; Sink, David W
2018-05-21
To reduce nonactionable oximeter alarms by 80% without increasing time infants were hypoxemic (oxygen saturation [SpO 2 ] ≤ 80%) or hyperoxemic (SpO 2 > 95% while on supplemental oxygen). In 2015, a multidisciplinary team at Connecticut Children's Medical Center initiated a quality improvement project to reduce nonactionable oximeter alarms in two referral neonatal intensive care units (NICUs). Changes made through improvement cycles included reduction of the low oximeter alarm limit for specific populations, increased low alarm delay, development of postmenstrual age-based alarm profiles, and updated bedside visual reminders. Manual alarm tallies and electronic SpO 2 data were collected throughout the project. Alarm tallies were collected for 158 patient care hours with SpO 2 data available for 138 of those hours. Mean number of total nonactionable alarms per patient per hour decreased from 9 to 2 (78% decrease) and the mean number of nonactionable low alarms per patient per hour decreased from 5 to 1 (80% decrease). No change was noted in the balancing measures of percentage time with SpO 2 ≤ 80% (mean 4.3%) or SpO 2 > 95% (mean 23.7%). Through small changes in oximeter alarm settings, including revision of alarm limits, alarm delays, and age-specific alarm profiles, our NICUs significantly reduced nonactionable alarms without increasing hypoxemia. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiaro, P.J.
A series of tests were performed at Oak Ridge National Laboratory (ORNL) to evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The ''Cricket'' is manufactured by RAD/COMM Systems Corp., which is located in Ontario, Canada. The system is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is mounted to the base of a grappler and monitors material, while the grappler's tines hold the material. It can also be used to scan material in an attempt to isolate radioactive material if an alarm occurs. Testing was performed at themore » Environmental Effects Laboratory located at ORNL and operated by the Engineering Science and Technology Division. Tests performed included the following: (1) Background stability, (2) Energy response using {sup 241}Am, {sup 137}Cs, and {sup 60}Co, (3) Surface uniformity, (4) Angular dependence, (5) Alarm actuation, (6) Alarm threshold vs. background, (7) Shielding, (8) Response to {sup 235}U, (9) Response to neutrons using unmoderated {sup 252}Cf, and (10) Response to transient radiation. This report presents a summary of the test results. Background measurements were obtained prior to the performance of each individual test.« less
Research on Vehicle-Based Driver Status/Performance Monitoring, Part III
DOT National Transportation Integrated Search
1996-09-01
A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...
Research On Vehicle-Based Driver Status/Performance Monitoring, Part I
DOT National Transportation Integrated Search
1996-09-01
A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...
Machine learning for real time remote detection
NASA Astrophysics Data System (ADS)
Labbé, Benjamin; Fournier, Jérôme; Henaff, Gilles; Bascle, Bénédicte; Canu, Stéphane
2010-10-01
Infrared systems are key to providing enhanced capability to military forces such as automatic control of threats and prevention from air, naval and ground attacks. Key requirements for such a system to produce operational benefits are real-time processing as well as high efficiency in terms of detection and false alarm rate. These are serious issues since the system must deal with a large number of objects and categories to be recognized (small vehicles, armored vehicles, planes, buildings, etc.). Statistical learning based algorithms are promising candidates to meet these requirements when using selected discriminant features and real-time implementation. This paper proposes a new decision architecture benefiting from recent advances in machine learning by using an effective method for level set estimation. While building decision function, the proposed approach performs variable selection based on a discriminative criterion. Moreover, the use of level set makes it possible to manage rejection of unknown or ambiguous objects thus preserving the false alarm rate. Experimental evidences reported on real world infrared images demonstrate the validity of our approach.
Cammaerts, Marie-Claire
2014-01-01
Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants' ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.
46 CFR 113.25-3 - Requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Requirements. 113.25-3 Section 113.25-3 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-3 Requirements. Each vessel must have a general emergency alarm system that meets the requirements of this subpart. ...
46 CFR 113.25-3 - Requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Requirements. 113.25-3 Section 113.25-3 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-3 Requirements. Each vessel must have a general emergency alarm system that meets the requirements of this subpart. ...
46 CFR 113.25-3 - Requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Requirements. 113.25-3 Section 113.25-3 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-3 Requirements. Each vessel must have a general emergency alarm system that meets the requirements of this subpart. ...
46 CFR 113.43-5 - Power supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm system must be supplied by a circuit that: (a) Is independent of other steering gear system and steering...
46 CFR 113.43-5 - Power supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm system must be supplied by a circuit that: (a) Is independent of other steering gear system and steering...
SCADA alarms processing for wind turbine component failure detection
NASA Astrophysics Data System (ADS)
Gonzalez, E.; Reder, M.; Melero, J. J.
2016-09-01
Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.
Design of overload vehicle monitoring and response system based on DSP
NASA Astrophysics Data System (ADS)
Yu, Yan; Liu, Yiheng; Zhao, Xuefeng
2014-03-01
The overload vehicles are making much more damage to the road surface than the regular ones. Many roads and bridges are equipped with structural health monitoring system (SHM) to provide early-warning to these damage and evaluate the safety of road and bridge. However, because of the complex nature of SHM system, it's expensive to manufacture, difficult to install and not well-suited for the regular bridges and roads. Based on this application background, this paper designs a compact structural health monitoring system based on DSP, which is highly integrated, low-power, easy to install and inexpensive to manufacture. The designed system is made up of sensor arrays, the charge amplifier module, the DSP processing unit, the alarm system for overload, and the estimate for damage of the road and bridge structure. The signals coming from sensor arrays go through the charge amplifier. DSP processing unit will receive the amplified signals, estimate whether it is an overload signal or not, and convert analog variables into digital ones so that they are compatible with the back-end digital circuit for further processing. The system will also restrict certain vehicles that are overweight, by taking image of the car brand, sending the alarm, and transferring the collected pressure data to remote data center for further monitoring analysis by rain-flow counting method.
5. DETAIL VIEW OF OLD, PUNCHTYPE MASTER FIRE ALARM SYSTEM, ...
5. DETAIL VIEW OF OLD, PUNCH-TYPE MASTER FIRE ALARM SYSTEM, LOCATED ON S WALL OF ENGINE STORAGE ROOM; LOOKING S. (Ceronie and Ryan) - Watervliet Arsenal, Building No. 22, Westervelt Avenue & Buffington Street, Watervliet, Albany County, NY
NASA Astrophysics Data System (ADS)
Pignaton de Freitas, Edison; Heimfarth, Tales; Pereira, Carlos Eduardo; Morado Ferreira, Armando; Rech Wagner, Flávio; Larsson, Tony
2010-04-01
A current trend that is gaining strength in the wireless sensor network area is the use of heterogeneous sensor nodes in one coordinated overall network, needed to fulfill the requirements of sophisticated emerging applications, such as area surveillance systems. One of the main concerns when developing such sensor networks is how to provide coordination among the heterogeneous nodes, in order to enable them to efficiently respond the user needs. This study presents an investigation of strategies to coordinate a set of static sensor nodes on the ground cooperating with wirelessly connected Unmanned Aerial Vehicles (UAVs) carrying a variety of sensors, in order to provide efficient surveillance over an area of interest. The sensor nodes on the ground are set to issue alarms on the occurrence of a given event of interest, e.g. entrance of a non-authorized vehicle in the area, while the UAVs receive the issued alarms and have to decide which of them is the most suitable to handle the issued alarm. A bio-inspired coordination strategy based on the concept of pheromones is presented. As a complement of this strategy, a utility-based decision making approach is proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanc, Katya Lee; Spielman, Zachary Alexander; Rice, Brandon Charles
2016-04-01
This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.
Expert system constant false alarm rate processor
NASA Astrophysics Data System (ADS)
Baldygo, William J., Jr.; Wicks, Michael C.
1993-10-01
The requirements for high detection probability and low false alarm probability in modern wide area surveillance radars are rarely met due to spatial variations in clutter characteristics. Many filtering and CFAR detection algorithms have been developed to effectively deal with these variations; however, any single algorithm is likely to exhibit excessive false alarms and intolerably low detection probabilities in a dynamically changing environment. A great deal of research has led to advances in the state of the art in Artificial Intelligence (AI) and numerous areas have been identified for application to radar signal processing. The approach suggested here, discussed in a patent application submitted by the authors, is to intelligently select the filtering and CFAR detection algorithms being executed at any given time, based upon the observed characteristics of the interference environment. This approach requires sensing the environment, employing the most suitable algorithms, and applying an appropriate multiple algorithm fusion scheme or consensus algorithm to produce a global detection decision.
Explosive hazard detection using MIMO forward-looking ground penetrating radar
NASA Astrophysics Data System (ADS)
Shaw, Darren; Ho, K. C.; Stone, Kevin; Keller, James M.; Popescu, Mihail; Anderson, Derek T.; Luke, Robert H.; Burns, Brian
2015-05-01
This paper proposes a machine learning algorithm for subsurface object detection on multiple-input-multiple-output (MIMO) forward-looking ground-penetrating radar (FLGPR). By detecting hazards using FLGPR, standoff distances of up to tens of meters can be acquired, but this is at the degradation of performance due to high false alarm rates. The proposed system utilizes an anomaly detection prescreener to identify potential object locations. Alarm locations have multiple one-dimensional (ML) spectral features, two-dimensional (2D) spectral features, and log-Gabor statistic features extracted. The ability of these features to reduce the number of false alarms and increase the probability of detection is evaluated for both co-polarizations present in the Akela MIMO array. Classification is performed by a Support Vector Machine (SVM) with lane-based cross-validation for training and testing. Class imbalance and optimized SVM kernel parameters are considered during classifier training.
46 CFR 182.530 - Bilge high level alarms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Bilge high level alarms. 182.530 Section 182.530... TONS) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.530 Bilge high level alarms. (a) On a... operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A...
Asirdizer, Mahmut; Turkmen, Nursel; Akan, Okan; Yavuz, Mehmet Sunay
2014-06-01
Injury and death cases caused by booby traps are not common in forensic medicine practice. Besides, installation of booby traps including firearms is generally for suicidal and rarely for homicidal purposes. Although few patents were described about home security alarm system that were created by firearms in the United States, 1 sample of injury with a similar unconventional mechanism of home safety system was reported by Asirdizer and Yavuz in 2009. In the published case report, the story of an electrical technician who was invited to a summer house by the homeowner to check the home security alarm system was reported. In the so-called report, he was stated to be injured by the shotgun attached to the unconventional home security alarm system while checking the system. As a result, the homeowner was convicted of a possible intent to cause a life-threatening injury to the technician.The so-called homeowner and his wife died by the same shotgun attached to the same unconventional home security alarm system 4 years on from the first event. In the present case report, we have aimed to present the findings of the crime scene and the autopsies of these unusual 2 deaths and to discuss individual and legal factors in paving the way for the deaths of 2 people.
40 CFR 63.11583 - What are my monitoring requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... preparation operation are in target HAP service: (a) Operate a bag leak detection system with alarm that will alert operators of a leak in the control device filter material. If a bag leak detection system with... install, calibrate, operate, and maintain each bag leak detection system and alarm according to...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2014-07-01 2014-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2011-07-01 2011-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2013-07-01 2013-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2012-07-01 2012-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
33 CFR 149.130 - What are the requirements for the cargo transfer system alarm?
Code of Federal Regulations, 2011 CFR
2011-07-01
... cargo transfer system alarm? 149.130 Section 149.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT Pollution Prevention Equipment § 149.130 What are the requirements for the cargo transfer system...
33 CFR 149.130 - What are the requirements for the cargo transfer system alarm?
Code of Federal Regulations, 2010 CFR
2010-07-01
... cargo transfer system alarm? 149.130 Section 149.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT Pollution Prevention Equipment § 149.130 What are the requirements for the cargo transfer system...
Solar Energetic Particle Forecasting Algorithms and Associated False Alarms
NASA Astrophysics Data System (ADS)
Swalwell, B.; Dalla, S.; Walsh, R. W.
2017-11-01
Solar energetic particle (SEP) events are known to occur following solar flares and coronal mass ejections (CMEs). However, some high-energy solar events do not result in SEPs being detected at Earth, and it is these types of event which may be termed "false alarms". We define two simple SEP forecasting algorithms based upon the occurrence of a magnetically well-connected CME with a speed in excess of 1500 km s^{-1} (a "fast" CME) or a well-connected X-class flare and analyse them with respect to historical datasets. We compare the parameters of those solar events which produced an enhancement of {>} 40 MeV protons at Earth (an "SEP event") and the parameters of false alarms. We find that an SEP forecasting algorithm based solely upon the occurrence of a well-connected fast CME produces fewer false alarms (28.8%) than an algorithm which is based solely upon a well-connected X-class flare (50.6%). Both algorithms fail to forecast a relatively high percentage of SEP events (53.2% and 50.6%, respectively). Our analysis of the historical datasets shows that false-alarm X-class flares were either not associated with any CME, or were associated with a CME slower than 500 km s^{-1}; false-alarm fast CMEs tended to be associated with flare classes lower than M3. A better approach to forecasting would be an algorithm which takes as its base the occurrence of both CMEs and flares. We define a new forecasting algorithm which uses a combination of CME and flare parameters, and we show that the false-alarm ratio is similar to that for the algorithm based upon fast CMEs (29.6%), but the percentage of SEP events not forecast is reduced to 32.4%. Lists of the solar events which gave rise to {>} 40 MeV protons and the false alarms have been derived and are made available to aid further study.
Winters, Bradford D; Cvach, Maria M; Bonafide, Christopher P; Hu, Xiao; Konkani, Avinash; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; Pelter, Michele M; McLean, Barbara; Kane-Gill, Sandra L
2018-01-01
Alarm fatigue is a widely recognized safety and quality problem where exposure to high rates of clinical alarms results in desensitization leading to dismissal of or slowed response to alarms. Nonactionable alarms are thought to be especially problematic. Despite these concerns, the number of clinical alarm signals has been increasing as an everincreasing number of medical technologies are added to the clinical care environment. PubMed, SCOPUS, Embase, and CINAHL. We performed a systematic review of the literature focused on clinical alarms. We asked a primary key question; "what interventions have been attempted and resulted in the success of reducing alarm fatigue?" and 3-secondary key questions; "what are the negative effects on patients/families; what are the balancing outcomes (unintended consequences of interventions); and what human factor approaches apply to making an effective alarm?" Articles relevant to the Key Questions were selected through an iterative review process and relevant data was extracted using a standardized tool. We found 62 articles that had relevant and usable data for at least one key question. We found that no study used/developed a clear definition of "alarm fatigue." For our primary key question 1, the relevant studies focused on three main areas: quality improvement/bundled activities; intervention comparisons; and analysis of algorithm-based false and total alarm suppression. All sought to reduce the number of total alarms and/or false alarms to improve the positive predictive value. Most studies were successful to varying degrees. None measured alarm fatigue directly. There is no agreed upon valid metric(s) for alarm fatigue, and the current methods are mostly indirect. Assuming that reducing the number of alarms and/or improving positive predictive value can reduce alarm fatigue, there are promising avenues to address patient safety and quality problem. Further investment is warranted not only in interventions that may reduce alarm fatigue but also in defining how to best measure it.
McGarraugh, Geoffrey
2010-01-01
Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG); all CGM alarms require SMBG confirmation before treatment. In this report, an analysis method is proposed to determine the CGM threshold alarm accuracy required to eliminate SMBG confirmation. The proposed method builds on the Clinical and Laboratory Standards Institute (CLSI) guideline for evaluating CGM threshold alarms using data from an in-clinic study of subjects with type 1 diabetes. The CLSI method proposes a maximum time limit of +/-30 minutes for the detection of hypo- and hyperglycemic events but does not include limits for glucose measurement accuracy. The International Standards Organization (ISO) standard for SMBG glucose measurement accuracy (ISO 15197) is +/-15 mg/dl for glucose <75 mg/dl and +/-20% for glucose > or = 75 mg/dl. This standard was combined with the CLSI method to more completely characterize the accuracy of CGM alarms. Incorporating the ISO 15197 accuracy margins, FreeStyle Navigator CGM system alarms detected 70 mg/dl hypoglycemia within 30 minutes at a rate of 70.3%, with a false alarm rate of 11.4%. The device detected high glucose in the range of 140-300 mg/dl within 30 minutes at an average rate of 99.2%, with a false alarm rate of 2.1%. Self-monitoring of blood glucose confirmation is necessary for detecting and treating hypoglycemia with the FreeStyle Navigator CGM system, but at high glucose levels, SMBG confirmation adds little incremental value to CGM alarms. 2010 Diabetes Technology Society.
Fire detection system using random forest classification for image sequences of complex background
NASA Astrophysics Data System (ADS)
Kim, Onecue; Kang, Dong-Joong
2013-06-01
We present a fire alarm system based on image processing that detects fire accidents in various environments. To reduce false alarms that frequently appeared in earlier systems, we combined image features including color, motion, and blinking information. We specifically define the color conditions of fires in hue, saturation and value, and RGB color space. Fire features are represented as intensity variation, color mean and variance, motion, and image differences. Moreover, blinking fire features are modeled by using crossing patches. We propose an algorithm that classifies patches into fire or nonfire areas by using random forest supervised learning. We design an embedded surveillance device made with acrylonitrile butadiene styrene housing for stable fire detection in outdoor environments. The experimental results show that our algorithm works robustly in complex environments and is able to detect fires in real time.
An approach for representing sensor data to validate alerts in Ambient Assisted Living.
Muñoz, Andrés; Serrano, Emilio; Villa, Ana; Valdés, Mercedes; Botía, Juan A
2012-01-01
The mainstream of research in Ambient Assisted Living (AAL) is devoted to developing intelligent systems for processing the data collected through artificial sensing. Besides, there are other elements that must be considered to foster the adoption of AAL solutions in real environments. In this paper we focus on the problem of designing interfaces among caregivers and AAL systems. We present an alert management tool that supports carers in their task of validating alarms raised by the system. It generates text-based explanations--obtained through an argumentation process--of the causes leading to alarm activation along with graphical sensor information and 3D models, thus offering complementary types of information. Moreover, a guideline to use the tool when validating alerts is also provided. Finally, the functionality of the proposed tool is demonstrated through two real cases of alert.
NASA Astrophysics Data System (ADS)
Ciurapiński, Wieslaw; Dulski, Rafal; Kastek, Mariusz; Szustakowski, Mieczyslaw; Bieszczad, Grzegorz; Życzkowski, Marek; Trzaskawka, Piotr; Piszczek, Marek
2009-09-01
The paper presents the concept of multispectral protection system for perimeter protection for stationary and moving objects. The system consists of active ground radar, thermal and visible cameras. The radar allows the system to locate potential intruders and to control an observation area for system cameras. The multisensor construction of the system ensures significant improvement of detection probability of intruder and reduction of false alarms. A final decision from system is worked out using image data. The method of data fusion used in the system has been presented. The system is working under control of FLIR Nexus system. The Nexus offers complete technology and components to create network-based, high-end integrated systems for security and surveillance applications. Based on unique "plug and play" architecture, system provides unmatched flexibility and simplistic integration of sensors and devices in TCP/IP networks. Using a graphical user interface it is possible to control sensors and monitor streaming video and other data over the network, visualize the results of data fusion process and obtain detailed information about detected intruders over a digital map. System provides high-level applications and operator workload reduction with features such as sensor to sensor cueing from detection devices, automatic e-mail notification and alarm triggering.
46 CFR 62.35-40 - Fuel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Fuel systems. 62.35-40 Section 62.35-40 Shipping COAST... Requirements for Specific Types of Automated Vital Systems § 62.35-40 Fuel systems. (a) Level alarms. Where high or low fuel tank level alarms are required, they must be located to allow the operator adequate...
46 CFR 62.35-40 - Fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Fuel systems. 62.35-40 Section 62.35-40 Shipping COAST... Requirements for Specific Types of Automated Vital Systems § 62.35-40 Fuel systems. (a) Level alarms. Where high or low fuel tank level alarms are required, they must be located to allow the operator adequate...
46 CFR 62.35-40 - Fuel systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Fuel systems. 62.35-40 Section 62.35-40 Shipping COAST... Requirements for Specific Types of Automated Vital Systems § 62.35-40 Fuel systems. (a) Level alarms. Where high or low fuel tank level alarms are required, they must be located to allow the operator adequate...
46 CFR 62.35-40 - Fuel systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Fuel systems. 62.35-40 Section 62.35-40 Shipping COAST... Requirements for Specific Types of Automated Vital Systems § 62.35-40 Fuel systems. (a) Level alarms. Where high or low fuel tank level alarms are required, they must be located to allow the operator adequate...
Spillage detector for liquid chromatography systems
NASA Technical Reports Server (NTRS)
Jarvis, M. J.; Fulton, D. S. (Inventor)
1986-01-01
A spillage detector device for use in conjunction with fractionation of liquid chromatography systems which includes a spillage recieving enclosure beneath the fractionation area is described. A sensing device having a plurality of electrodes of alternating polarity is mounted within the spillage recieving enclosure. Detection circuitry, responsive to conductivity between electrodes, is operatively connected to the sensing device. The detection circuitry feeds into the output circuitry. The output circuit has relaying and switching circuitry directed to a solenoid, an alarm system and a pump. The solenoid is connected to the pliable conduit of the chromatography system. The alarm system comprises an audio alarm and a visual signal. A 115-volt power system interconnected with the pump, the solenoid, the sensing device, and the detection and output circuitry.
False alarm reduction by the And-ing of multiple multivariate Gaussian classifiers
NASA Astrophysics Data System (ADS)
Dobeck, Gerald J.; Cobb, J. Tory
2003-09-01
The high-resolution sonar is one of the principal sensors used by the Navy to detect and classify sea mines in minehunting operations. For such sonar systems, substantial effort has been devoted to the development of automated detection and classification (D/C) algorithms. These have been spurred by several factors including (1) aids for operators to reduce work overload, (2) more optimal use of all available data, and (3) the introduction of unmanned minehunting systems. The environments where sea mines are typically laid (harbor areas, shipping lanes, and the littorals) give rise to many false alarms caused by natural, biologic, and man-made clutter. The objective of the automated D/C algorithms is to eliminate most of these false alarms while still maintaining a very high probability of mine detection and classification (PdPc). In recent years, the benefits of fusing the outputs of multiple D/C algorithms have been studied. We refer to this as Algorithm Fusion. The results have been remarkable, including reliable robustness to new environments. This paper describes a method for training several multivariate Gaussian classifiers such that their And-ing dramatically reduces false alarms while maintaining a high probability of classification. This training approach is referred to as the Focused- Training method. This work extends our 2001-2002 work where the Focused-Training method was used with three other types of classifiers: the Attractor-based K-Nearest Neighbor Neural Network (a type of radial-basis, probabilistic neural network), the Optimal Discrimination Filter Classifier (based linear discrimination theory), and the Quadratic Penalty Function Support Vector Machine (QPFSVM). Although our experience has been gained in the area of sea mine detection and classification, the principles described herein are general and can be applied to a wide range of pattern recognition and automatic target recognition (ATR) problems.
ERIC Educational Resources Information Center
Zimmerman, Jim
1992-01-01
Students examine the concepts of electrical circuits and switches by building their own alarm systems. Students apply their understanding by creating recorder, window, pressure sensitive, and lunch box alarms. (MDH)
40 CFR 63.1178 - For cupolas, what standards must I meet?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Begin within one hour after the alarm on a bag leak detection system sounds, and complete in a timely... § 63.1187 of this subpart. (2) When the alarm on a bag leak detection system sounds for more than five...
An initial survey of national airspace system auditory alarm issues in terminal air traffic control.
DOT National Transportation Integrated Search
2003-04-01
A researcher from the Research Development & Human Factors Laboratory of the William J. Hughes Technical Center conducted an exploratory study to examine current National Airspace System (NAS) auditory alarm issues. The purpose was to identify proble...
46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section 196.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using...
46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section 196.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using...
46 CFR 169.732 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 169.732 Section 169.732 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide and clean agent alarms. (a) Each carbon dioxide o...
46 CFR 169.732 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 169.732 Section 169.732 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide and clean agent alarms. (a) Each carbon dioxide o...
46 CFR 169.732 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 169.732 Section 169.732 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide and clean agent alarms. (a) Each carbon dioxide o...
46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section 196.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using...
46 CFR 161.002-8 - Automatic fire detecting systems, general requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... detecting system shall consist of a power supply; a control unit on which are located visible and audible... control unit. Power failure alarm devices may be separately housed from the control unit and may be combined with other power failure alarm systems when specifically approved. (b) [Reserved] [21 FR 9032, Nov...
46 CFR 161.002-8 - Automatic fire detecting systems, general requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... detecting system shall consist of a power supply; a control unit on which are located visible and audible... control unit. Power failure alarm devices may be separately housed from the control unit and may be combined with other power failure alarm systems when specifically approved. (b) [Reserved] [21 FR 9032, Nov...
75 FR 13295 - Buy American Exceptions Under the American Recovery and Reinvestment Act of 2009
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-19
... Housing Authority for the purchase and installation of an Access Control and Alarm Monitoring system at... Alarm Monitoring system) are not produced in the U.S. in sufficient and reasonably available quantities..., for the purchase and installation of two ductless split systems for the Elevator Modernization and...
ERIC Educational Resources Information Center
Powers, Joelle D.; Edwards, Jeffrey D.; Blackman, Kate F.; Wegmann, Kate M.
2013-01-01
The alarming number of youth with unmet mental health needs in the US is a significant social problem. The pilot school-based mental health project described here established an innovative multi-system partnership between an urban school district, a public mental health agency, and a local university to better meet the mental health needs of youth…
Conradsen, Isa; Beniczky, Sandor; Wolf, Peter; Terney, Daniella; Sams, Thomas; Sorensen, Helge B D
2009-01-01
Many epilepsy patients cannot call for help during a seizure, because they are unconscious or because of the affection of their motor system or speech function. This can lead to injuries, medical complications and at worst death. An alarm system setting off at seizure onset could help to avoid hazards. Today no reliable alarm systems are available. A Multi-modal Intelligent Seizure Acquisition (MISA) system based on full body motion data seems as a good approach towards detection of epileptic seizures. The system is the first to provide a full body description for epilepsy applications. Three test subjects were used for this pilot project. Each subject simulated 15 seizures and in addition performed some predefined normal activities, during a 4-hour monitoring with electromyography (EMG), accelerometer, magnetometer and gyroscope (AMG), electrocardiography (ECG), electroencephalography (EEG) and audio and video recording. The results showed that a non-subject specific MISA system developed on data from the modalities: accelerometer (ACM), gyroscope and EMG is able to detect 98% of the simulated seizures and at the same time mistakes only 4 of the normal movements for seizures. If the system is individualized (subject specific) it is able to detect all simulated seizures with a maximum of 1 false positive. Based on the results from the simulated seizures and normal movements the MISA system seems to be a promising approach to seizure detection.
Joshi, Rohan; Straaten, Henrica van; Mortel, Heidi van de; Long, Xi; Andriessen, Peter; Pul, Carola van
2018-06-30
To determine differences in alarm pressure between two otherwise comparable neonatal intensive care units (NICUs) differing in architectural layout-one of a single-family room (SFR) design and the other of an open bay area (OBA) design. Retrospective audit of more than 2000 patient days from each NICU cataloguing the differences in the number and duration of alarms for critical and alerting alarms, as well as the interaction of clinicians with the patient monitor. Two level 3 NICUs. A total of more than 150 000 critical and 1.2 million alerting alarms were acquired from the two NICUs. The number of audible alarms and the associated noise pollution varied considerably with the OBA NICU generating 44% more alarms per infant per day even though the SFR NICU generated 2.5 as many critical desaturation alarms per infant per day. Differences in the architectural layout of NICUs and the consequent differences in delays, thresholds and distribution systems for alarms are associated with differences in alarm pressure. © Author(s) (or their employer(s)) 2018. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.
NASA Astrophysics Data System (ADS)
Lightstone, P. C.; Davidson, W. M.
1982-04-01
The military detection assessment laboratory houses an experimental field system which assesses different alarm indicators such as fence disturbance sensors, MILES cables, and microwave Racons. A speech synthesis board which could be interfaced, by means of a computer, to an alarm logger making verbal acknowledgement of alarms possible was purchased. Different products and different types of voice synthesis were analyzed before a linear predictive code device produced by Telesensory Speech Systems of Palo Alto, California was chosen. This device is called the Speech 1000 Board and has a dedicated 8085 processor. A multiplexer card was designed and the Sp 1000 interfaced through the card into a TMS 990/100M Texas Instrument microcomputer. It was also necessary to design the software with the capability of recognizing and flagging an alarm on any 1 of 32 possible lines. The experimental field system was then packaged with a dc power supply, LED indicators, speakers, and switches, and deployed in the field performing reliably.
46 CFR 113.05-7 - Environmental tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Environmental tests. 113.05-7 Section 113.05-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Provisions § 113.05-7 Environmental tests. Communication, alarm system...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
Automated Information System (AIS) Alarm System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunteman, W.
1997-05-01
The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, themore » assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.« less
Nuthatches eavesdrop on variations in heterospecific chickadee mobbing alarm calls
Templeton, Christopher N.; Greene, Erick
2007-01-01
Many animals recognize the alarm calls produced by other species, but the amount of information they glean from these eavesdropped signals is unknown. We previously showed that black-capped chickadees (Poecile atricapillus) have a sophisticated alarm call system in which they encode complex information about the size and risk of potential predators in variations of a single type of mobbing alarm call. Here we show experimentally that red-breasted nuthatches (Sitta canadensis) respond appropriately to subtle variations of these heterospecific “chick-a-dee” alarm calls, thereby evidencing that they have gained important information about potential predators in their environment. This study demonstrates a previously unsuspected level of discrimination in intertaxon eavesdropping. PMID:17372225
Nuthatches eavesdrop on variations in heterospecific chickadee mobbing alarm calls.
Templeton, Christopher N; Greene, Erick
2007-03-27
Many animals recognize the alarm calls produced by other species, but the amount of information they glean from these eavesdropped signals is unknown. We previously showed that black-capped chickadees (Poecile atricapillus) have a sophisticated alarm call system in which they encode complex information about the size and risk of potential predators in variations of a single type of mobbing alarm call. Here we show experimentally that red-breasted nuthatches (Sitta canadensis) respond appropriately to subtle variations of these heterospecific "chick-a-dee" alarm calls, thereby evidencing that they have gained important information about potential predators in their environment. This study demonstrates a previously unsuspected level of discrimination in intertaxon eavesdropping.
Alpini, Dario; Cesarani, Antonio; Hahn, Ales
2007-01-01
Stress is a significant factor influencing the clinical course of tinnitus. The auditory system is particularly sensitive to the effects of various stress factors (chemical, oxidative, emotional, etc.). Different stages of reaction (alarm, resistance, exhaustion) lead to different characteristics of tinnitus and to different therapeutic approaches. Individual characteristics of stress reaction may explain different aspects of tinnitus in various patients with different responses to treatment, despite similar audiological and etiological factors. A model based on individual reactions to stress factors (stress-reaction tinnitus model, or SRTM) could explain tinnitus as an alarm signal. In each patient, stressors have to be identified during the alarm phase to prevent an evolution toward the resistance and exhaustion phases. In the exhaustion phase, chronic tinnitus is due to the organization of a paradoxical auditory memory and a pathologically shifted attention to tinnitus. The aim of our study is to describe a therapeutic proposal based on the SRTM by taking an educational approach to management of chronic tinnitus. The educational aspect is emphasized; thus, we named our approach tinnitus school. Selection of appropriate patients and follow-up is based on psychometrics of tinnitus and stress questionnaires, including a tinnitus reaction questionnaire, a tinnitus cognitive questionnaire, and a 20-item perceived stress questionnaire. Tinnitus school is a three-phase program: counseling, training, and home training. Training is based on a tinnitus-fitted physiotherapeutic protocol.
2012-01-01
Background Reporting of symptoms which may signal cancer is the first step in the diagnostic pathway of cancer diseases. Cancer alarm symptoms are common in the general population. Public awareness and knowledge of cancer symptoms are sparse, however, and many people do not seek medical help when having possible cancer symptoms. As social inequality is associated with cancer knowledge, cancer awareness, and information-seeking, our hypothesis is that social inequality may also exist in the general population with respect to reporting of cancer alarm symptoms. The aim of this study was to investigate possible associations between socioeconomic and demographic determinants and reporting of common cancer alarm symptoms. Methods A cross-sectional questionnaire survey was performed based on a stratified sample of the Danish general population. A total of 13 777 randomly selected persons aged 20 years and older participated. Our main outcome measures were weighted prevalence estimates of self-reporting one of the following cancer alarm symptoms during the preceding 12 months: a lump in the breast, coughing for more than 6 weeks, seen blood in urine, or seen blood in stool. Logistic regression models were used to calculate unadjusted and adjusted odds ratios with 95% confidence intervals for the associations between each covariate and reporting of cancer alarm symptoms. Results A total of 2 098 (15.7%) of the participants reported one or more cancer alarm symptoms within the preceding 12 months. Women, subjects out of the workforce, and subjects with a cancer diagnosis had statistically significantly higher odds of reporting one or more cancer alarm symptoms. Subjects with older age and subjects living with a partner had lower odds of reporting one or more cancer alarm symptoms. When analysing the four alarm symptoms of cancer separately most tendencies persisted. Conclusions Socioeconomic and demographic determinants are associated with self-reporting of common cancer alarm symptoms. PMID:22914003
B-Plant Canyon Ventilation Control System Description
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCDANIEL, K.S.
1999-08-31
Project W-059 installed a new B Plant Canyon Ventilation System. Monitoring and control of the system is implemented by the Canyon Ventilation Control System (CVCS). This document describes the CVCS system components which include a Programmable Logic Controller (PLC) coupled with an Operator Interface Unit (OIU) and application software. This document also includes an Alarm Index specifying the setpoints and technical basis for system analog and digital alarms.
NASA Technical Reports Server (NTRS)
Begault, Durand R.; Godfroy, Martine; Sandor, Aniko; Holden, Kritina
2008-01-01
The design of caution-warning signals for NASA s Crew Exploration Vehicle (CEV) and other future spacecraft will be based on both best practices based on current research and evaluation of current alarms. A design approach is presented based upon cross-disciplinary examination of psychoacoustic research, human factors experience, aerospace practices, and acoustical engineering requirements. A listening test with thirteen participants was performed involving ranking and grading of current and newly developed caution-warning stimuli under three conditions: (1) alarm levels adjusted for compliance with ISO 7731, "Danger signals for work places - Auditory Danger Signals", (2) alarm levels adjusted to an overall 15 dBA s/n ratio and (3) simulated codec low-pass filtering. Questionnaire data yielded useful insights regarding cognitive associations with the sounds.
2010-06-01
to result in lower maintenance and higher reliability compared with the commercially practiced options of pressure swing adsorption (PSA) or vacuum ...screen and the temperature displayed on the graph will decrease. The Knob is used to zoom the chart and scroll through historical values. For a list of...Friday ‐ Status: OK. Tinker AFB reported a FAL alarm occurs when the compressor isn’t pumping oxygen. The FAL alarm terminates when the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ondrej Linda; Dumidu Wijayasekara; Milos Manic
Resiliency and improved state-awareness of modern critical infrastructures, such as energy production and industrial systems, is becoming increasingly important. As control systems become increasingly complex, the number of inputs and outputs increase. Therefore, in order to maintain sufficient levels of state-awareness, a robust system state monitoring must be implemented that correctly identifies system behavior even when one or more sensors are faulty. Furthermore, as intelligent cyber adversaries become more capable, incorrect values may be fed to the operators. To address these needs, this paper proposes a Fuzzy-Neural Data Fusion Engine (FN-DFE) for resilient state-awareness of control systems. The designed FN-DFEmore » is composed of a three-layered system consisting of: 1) traditional threshold based alarms, 2) anomalous behavior detector using self-organizing fuzzy logic system, and 3) artificial neural network based system modeling and prediction. The improved control system state-awareness is achieved via fusing input data from multiple sources and combining them into robust anomaly indicators. In addition, the neural network based signal predictions are used to augment the resiliency of the system and provide coherent state-awareness despite temporary unavailability of sensory data. The proposed system was integrated and tested with a model of the Idaho National Laboratory’s (INL) hybrid energy system facility know as HYTEST. Experimental results demonstrate that the proposed FN-DFE provides timely plant performance monitoring and anomaly detection capabilities. It was shown that the system is capable of identifying intrusive behavior significantly earlier than conventional threshold based alarm systems.« less
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Application. 76.35-1 Section 76.35-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-1 Application. (a) Where a manual alarm system is installed, the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Application. 76.35-1 Section 76.35-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-1 Application. (a) Where a manual alarm system is installed, the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Application. 76.35-1 Section 76.35-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-1 Application. (a) Where a manual alarm system is installed, the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Application. 76.35-1 Section 76.35-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-1 Application. (a) Where a manual alarm system is installed, the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Application. 76.35-1 Section 76.35-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-1 Application. (a) Where a manual alarm system is installed, the...
40 CFR 62.14690 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2011 CFR
2011-07-01
... alarm system that will sound automatically when an increase in relative particulate matter emissions over a preset level is detected. The alarm must be located where it is easily heard by plant operating personnel. (7) For positive pressure fabric filter systems, a bag leak detection system must be installed in...
46 CFR 27.209 - What are the requirements for training crews to respond to fires?
Code of Federal Regulations, 2010 CFR
2010-10-01
... the engine room and effectively seal all natural openings to the space to prevent leakage of the.... (3) Reporting inoperative alarm systems and fire-detection systems. (4) Putting on a fireman's outfit...) Testing of all alarm and detection systems; and (4) Putting on protective clothing (by at least one person...
Simulation analysis of a wildfire suppression system
Abílio Pereira Pacheco; João Claro; Tiago Oliveira
2013-01-01
Rekindles and false alarms are unusually high in the Portuguese wildfire management system, representing a high burden on suppression resources in particular, and fire management resources in general. In 20,049 occurrences that the suppression system handled in the summer of 2010, 12.5% were false alarms and 15.0% were rekindles. We present a discreteevent simulation...
Digital Sequences and a Time Reversal-Based Impact Region Imaging and Localization Method
Qiu, Lei; Yuan, Shenfang; Mei, Hanfei; Qian, Weifeng
2013-01-01
To reduce time and cost of damage inspection, on-line impact monitoring of aircraft composite structures is needed. A digital monitor based on an array of piezoelectric transducers (PZTs) is developed to record the impact region of impacts on-line. It is small in size, lightweight and has low power consumption, but there are two problems with the impact alarm region localization method of the digital monitor at the current stage. The first one is that the accuracy rate of the impact alarm region localization is low, especially on complex composite structures. The second problem is that the area of impact alarm region is large when a large scale structure is monitored and the number of PZTs is limited which increases the time and cost of damage inspections. To solve the two problems, an impact alarm region imaging and localization method based on digital sequences and time reversal is proposed. In this method, the frequency band of impact response signals is estimated based on the digital sequences first. Then, characteristic signals of impact response signals are constructed by sinusoidal modulation signals. Finally, the phase synthesis time reversal impact imaging method is adopted to obtain the impact region image. Depending on the image, an error ellipse is generated to give out the final impact alarm region. A validation experiment is implemented on a complex composite wing box of a real aircraft. The validation results show that the accuracy rate of impact alarm region localization is approximately 100%. The area of impact alarm region can be reduced and the number of PZTs needed to cover the same impact monitoring region is reduced by more than a half. PMID:24084123
Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring.
Nassi, N; Piumelli, R; Lombardi, E; Landini, L; Donzelli, G; de Martino, M
2008-02-01
To compare transthoracic impedance (TTI/ECG) and pulse oximetry alarm traces detected during home monitoring in infants at risk of apnoea, bradycardia and hypoxaemia. A retrospective evaluation of the monitor downloads of 67 infants who had undergone either TTI/ECG or pulse oximetry home monitoring using a device which can detect both parameters. The patients were categorised as: apparent life-threatening events (n = 39), preterm infants (n = 21) and miscellaneous (n = 7). TTI/ECG and pulse oximetry alarm traces were scored as either true or false alarms. Classification criteria were based on visual analysis of the impedance and plethysmographic waveforms captured by the memory monitor every time alarm thresholds were violated. 5242 alarms occurred over 3452 days of monitoring: 4562 (87%) were false and 680 (13%) true. The mean duration of monitoring was 51 days (range 5-220 days). There were 2982 TTI/ECG false alarms (65% of the total) and 1580 pulse oximetry false alarms (35%) (p = 0.0042). Of the 680 true alarms, 507 (74%) were desaturations not attributable to central apnoea and 173 (26%) were true TTI/ECG alarms (p = 0.0013). Comparison of pulse oximetry and TTI/ECG alarm traces shows that true events were mostly attributable to desaturations, while false alarms were mainly provoked by TTI/ECG. The total number of false alarms is lower than reported in other studies using TTI/ECG only, thus indicating that monitoring using both pulse oximetry and TTI/ECG is suitable for home use. When the combination of both techniques is not feasible or not required, we recommend the use of motion resistant pulse oximetry alone.
An Approach for Representing Sensor Data to Validate Alerts in Ambient Assisted Living
Muñoz, Andrés; Serrano, Emilio; Villa, Ana; Valdés, Mercedes; Botía, Juan A.
2012-01-01
The mainstream of research in Ambient Assisted Living (AAL) is devoted to developing intelligent systems for processing the data collected through artificial sensing. Besides, there are other elements that must be considered to foster the adoption of AAL solutions in real environments. In this paper we focus on the problem of designing interfaces among caregivers and AAL systems. We present an alert management tool that supports carers in their task of validating alarms raised by the system. It generates text-based explanations—obtained through an argumentation process—of the causes leading to alarm activation along with graphical sensor information and 3D models, thus offering complementary types of information. Moreover, a guideline to use the tool when validating alerts is also provided. Finally, the functionality of the proposed tool is demonstrated through two real cases of alert. PMID:22778642
Assessment of precursory information in seismo-electromagnetic phenomena
NASA Astrophysics Data System (ADS)
Han, P.; Hattori, K.; Zhuang, J.
2017-12-01
Previous statistical studies showed that there were correlations between seismo-electromagnetic phenomena and sizeable earthquakes in Japan. In this study, utilizing Molchan's error diagram, we evaluate whether these phenomena contain precursory information and discuss how they can be used in short-term forecasting of large earthquake events. In practice, for given series of precursory signals and related earthquake events, each prediction strategy is characterized by the leading time of alarms, the length of alarm window, the alarm radius (area) and magnitude. The leading time is the time length between a detected anomaly and its following alarm, and the alarm window is the duration that an alarm lasts. The alarm radius and magnitude are maximum predictable distance and minimum predictable magnitude of earthquake events, respectively. We introduce the modified probability gain (PG') and the probability difference (D') to quantify the forecasting performance and to explore the optimal prediction parameters for a given electromagnetic observation. The above methodology is firstly applied to ULF magnetic data and GPS-TEC data. The results show that the earthquake predictions based on electromagnetic anomalies are significantly better than random guesses, indicating the data contain potential useful precursory information. Meanwhile, we reveal the optimal prediction parameters for both observations. The methodology proposed in this study could be also applied to other pre-earthquake phenomena to find out whether there is precursory information, and then on this base explore the optimal alarm parameters in practical short-term forecast.
46 CFR 113.10-5 - Common return.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Common return. 113.10-5 Section 113.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-5 Common return. A conductor...
An Undergraduate Experiment in Alarm System Design.
ERIC Educational Resources Information Center
Martini, R. A.; And Others
1988-01-01
Describes an experiment involving data acquisition by a computer, digital signal transmission from the computer to a digital logic circuit and signal interpretation by this circuit. The system is being used at the Illinois Institute of Technology. Discusses the fundamental concepts involved. Demonstrates the alarm experiment as it is used in…
46 CFR 153.408 - Tank overflow control.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Tank overflow control. 153.408 Section 153.408 Shipping... Systems § 153.408 Tank overflow control. (a) When table 1 references this section, a cargo containment... the tank (automatic shutdown system). (b) The high level alarm and the cargo overflow alarm or...
46 CFR 108.445 - Alarm and means of escape.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.445...
46 CFR 113.25-6 - Power supply.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power source...
46 CFR 113.25-6 - Power supply.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power source...
46 CFR 113.25-6 - Power supply.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power source...
46 CFR 108.445 - Alarm and means of escape.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.445...
46 CFR 113.10-5 - Common return.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Common return. 113.10-5 Section 113.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-5 Common return. A conductor...
46 CFR 113.10-7 - Connection boxes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Connection boxes. 113.10-7 Section 113.10-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-7 Connection boxes. Each...
46 CFR 113.10-7 - Connection boxes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Connection boxes. 113.10-7 Section 113.10-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-7 Connection boxes. Each...
46 CFR 113.10-5 - Common return.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Common return. 113.10-5 Section 113.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-5 Common return. A conductor...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...
46 CFR 113.10-5 - Common return.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Common return. 113.10-5 Section 113.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-5 Common return. A conductor...
46 CFR 113.10-7 - Connection boxes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Connection boxes. 113.10-7 Section 113.10-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-7 Connection boxes. Each...
46 CFR 113.10-7 - Connection boxes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Connection boxes. 113.10-7 Section 113.10-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-7 Connection boxes. Each...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...
46 CFR 113.10-5 - Common return.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Common return. 113.10-5 Section 113.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-5 Common return. A conductor...
46 CFR 113.10-7 - Connection boxes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Connection boxes. 113.10-7 Section 113.10-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-7 Connection boxes. Each...
Research on distributed temperature sensor (DTS) applied in underground tunnel
NASA Astrophysics Data System (ADS)
Hu, Chuanlong; Wang, Jianfeng; Zhang, Zaixuan; Shen, Changyu; Jin, Yongxing; Jin, Shangzhong
2011-11-01
A distributed temperature sensor (DTS) system with a sensing distance of 4 km was developed for applications in tunnel temperature measurement and fire alarm. Characteristics of DTS and experiment results are introduced. The results show that DTS system can play an important role in tunnel fire alarm.
46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20... there is no off position. (5) Automation alarms must be separate and independent of the following: (i... with a means to test audible and visual annunciators; (iv) Provide for normal equipment starting and...
46 CFR 113.25-6 - Power supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power source...
46 CFR 113.25-6 - Power supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power source...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...
Automated real time constant-specificity surveillance for disease outbreaks.
Wieland, Shannon C; Brownstein, John S; Berger, Bonnie; Mandl, Kenneth D
2007-06-13
For real time surveillance, detection of abnormal disease patterns is based on a difference between patterns observed, and those predicted by models of historical data. The usefulness of outbreak detection strategies depends on their specificity; the false alarm rate affects the interpretation of alarms. We evaluate the specificity of five traditional models: autoregressive, Serfling, trimmed seasonal, wavelet-based, and generalized linear. We apply each to 12 years of emergency department visits for respiratory infection syndromes at a pediatric hospital, finding that the specificity of the five models was almost always a non-constant function of the day of the week, month, and year of the study (p < 0.05). We develop an outbreak detection method, called the expectation-variance model, based on generalized additive modeling to achieve a constant specificity by accounting for not only the expected number of visits, but also the variance of the number of visits. The expectation-variance model achieves constant specificity on all three time scales, as well as earlier detection and improved sensitivity compared to traditional methods in most circumstances. Modeling the variance of visit patterns enables real-time detection with known, constant specificity at all times. With constant specificity, public health practitioners can better interpret the alarms and better evaluate the cost-effectiveness of surveillance systems.
47 CFR 22.1007 - Channels for offshore radiotelephone systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... emergency auto alarm and voice transmission pertaining to emergency conditions only. Central Subscriber 488... fixed, surface and/or airborne mobile) as indicated, for emergency auto alarm and voice transmission...
47 CFR 22.1007 - Channels for offshore radiotelephone systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... emergency auto alarm and voice transmission pertaining to emergency conditions only. Central Subscriber 488... fixed, surface and/or airborne mobile) as indicated, for emergency auto alarm and voice transmission...
47 CFR 22.1007 - Channels for offshore radiotelephone systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... emergency auto alarm and voice transmission pertaining to emergency conditions only. Central Subscriber 488... fixed, surface and/or airborne mobile) as indicated, for emergency auto alarm and voice transmission...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
ERIC Educational Resources Information Center
Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Bosco, Andrea; Zonno, Nadia; Badagliacca, Francesco
2011-01-01
This study assessed whether three patients with Alzheimer's disease could learn to use urine alarms and caregivers' prompts to eliminate large urinary accidents. As soon as the patient began to release urine, the alarm system presented auditory and vibratory signals. In relation to those signals, the caregiver would prompt/encourage the patient to…
Frattaroli, Shannon; Schulman, Eric; McDonald, Eileen M; Omaki, Elise C; Shields, Wendy C; Jones, Vanya; Brewer, William
2018-05-17
Innovative strategies are needed to improve the prevalence of working smoke alarms in homes. To our knowledge, this is the first study to report on the effectiveness of Facebook advertising and automated telephone calls as population-level strategies to encourage an injury prevention behavior. We examine the effectiveness of Facebook advertising and automated telephone calls as strategies to enroll individuals in Baltimore City's Fire Department's free smoke alarm installation program. We directed our advertising efforts toward Facebook users eligible for the Baltimore City Fire Department's free smoke alarm installation program and all homes with a residential phone line included in Baltimore City's automated call system. The Facebook campaign targeted Baltimore City residents 18 years of age and older. In total, an estimated 300 000 Facebook users met the eligibility criteria. Facebook advertisements were delivered to users' desktop and mobile device newsfeeds. A prerecorded message was sent to all residential landlines listed in the city's automated call system. By the end of the campaign, the 3 advertisements generated 456 666 impressions reaching 130 264 Facebook users. Of the users reached, 4367 individuals (1.3%) clicked the advertisement. The automated call system included approximately 90 000 residential phone numbers. Participants attributed 25 smoke alarm installation requests to Facebook and 458 to the automated call. Facebook advertisements are a novel approach to promoting smoke alarms and appear to be effective in exposing individuals to injury prevention messages. However, converting Facebook message recipients to users of a smoke alarm installation program occurred infrequently in this study. Residents who participated in the smoke alarm installation program were more likely to cite the automated call as the impetus for their participation. Additional research is needed to understand the circumstances and strategies to effectively use the social networking site as a tool to convert passive users into active participants.
Chen, Fei-Fei; Zhu, Ying-Jie; Chen, Feng; Dong, Li-Ying; Yang, Ri-Long; Xiong, Zhi-Chao
2018-04-24
Wallpaper with multiple functions, such as fire resistance and an automatic alarm in fire disasters, will be attractive for the interior decoration of houses. Herein, we report a smart fire alarm wallpaper prepared using fire-resistant inorganic paper based on ultralong hydroxyapatite nanowires (HNs) and graphene oxide (GO) thermosensitive sensors. At room temperature, the GO thermosensitive sensor is in a state of electrical insulation; however, it becomes electrically conductive at high temperatures. In a fire disaster, high temperature will rapidly remove the oxygen-containing groups of GO, leading to the transformation process of GO from an electrically insulated state into an electrically conductive one. In this way, the alarm lamp and alarm buzzer connected with the GO thermosensitive sensor will send out the alerts to people immediately for taking emergency actions. After the surface modification with polydopamine of GO (PGO), the sensitivity and flame retardancy of the GO thermosensitive sensor are further improved, resulting in a low responsive temperature (126.9 °C), fast response (2 s), and sustained working time in the flame (at least 5 min). Compared with combustible commercial wallpaper, the smart fire alarm wallpaper based on HNs and GO (or PGO) is superior owing to excellent nonflammability and high-temperature resistance of HNs, which can protect the GO (or PGO) thermosensitive sensor from the flames. The smart fire alarm wallpaper can be processed into various shapes, dyed with different colors, and printed with the commercial printer and thus has promising applications in high-safety interior decoration of houses.
29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.
Code of Federal Regulations, 2010 CFR
2010-07-01
...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...
29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.
Code of Federal Regulations, 2011 CFR
2011-07-01
...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...
29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.
Code of Federal Regulations, 2014 CFR
2014-07-01
...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...
29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.
Code of Federal Regulations, 2013 CFR
2013-07-01
...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...
46 CFR 58.25-25 - Indicating and alarm systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... must activate in the machinery space upon— (1) Failure of any phase of a three-phase power supply; (2... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-25 Indicating and alarm systems. (a) Indication of the... accordance with § 112.15-5(h) of this chapter, draw its power from the source of emergency power. (c) On each...
46 CFR 58.25-25 - Indicating and alarm systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... must activate in the machinery space upon— (1) Failure of any phase of a three-phase power supply; (2... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-25 Indicating and alarm systems. (a) Indication of the... accordance with § 112.15-5(h) of this chapter, draw its power from the source of emergency power. (c) On each...
46 CFR 58.25-25 - Indicating and alarm systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... must activate in the machinery space upon— (1) Failure of any phase of a three-phase power supply; (2... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-25 Indicating and alarm systems. (a) Indication of the... accordance with § 112.15-5(h) of this chapter, draw its power from the source of emergency power. (c) On each...
Incorporation of operator knowledge for improved HMDS GPR classification
NASA Astrophysics Data System (ADS)
Kennedy, Levi; McClelland, Jessee R.; Walters, Joshua R.
2012-06-01
The Husky Mine Detection System (HMDS) detects and alerts operators to potential threats observed in groundpenetrating RADAR (GPR) data. In the current system architecture, the classifiers have been trained using available data from multiple training sites. Changes in target types, clutter types, and operational conditions may result in statistical differences between the training data and the testing data for the underlying features used by the classifier, potentially resulting in an increased false alarm rate or a lower probability of detection for the system. In the current mode of operation, the automated detection system alerts the human operator when a target-like object is detected. The operator then uses data visualization software, contextual information, and human intuition to decide whether the alarm presented is an actual target or a false alarm. When the statistics of the training data and the testing data are mismatched, the automated detection system can overwhelm the analyst with an excessive number of false alarms. This is evident in the performance of and the data collected from deployed systems. This work demonstrates that analyst feedback can be successfully used to re-train a classifier to account for variable testing data statistics not originally captured in the initial training data.
Preliminary Design of Critical Function Monitoring System of PGSFR
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-07-01
A PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor) is under development at Korea Atomic Energy Research Institute. A critical function monitoring system of the PGSFR is preliminarily studied. The functions of CFMS are to display critical plant variables related to the safety of the plant during normal and accident conditions and guide the operators corrective actions to keep the plant in a safe condition and mitigate the consequences of accidents. The minimal critical functions of the PGSFR are composed of reactivity control, reactor core cooling, reactor coolant system integrity, primary heat transfer system(PHTS) heat removal, sodium water reaction mitigation, radiation controlmore » and containment conditions. The variables and alarm legs of each critical function of the PGSFR are as follows; - Reactivity control: The variables of reactivity control function are power range neutron flux instrumentation, intermediate range neutron flux instrumentation, source range neutron flux instrumentation, and control rod bottom contacts. The alarm leg to display the reactivity controls consists of status of control drop malfunction, high post trip power and thermal reactivity addition. - Reactor core cooling: The variables are PHTS sodium level, hot pool temperature of PHTS, subassembly exit temperature, cold pool temperature of the PHTS, PHTS pump current, and PHTS pump breaker status. The alarm leg consists of high core delta temperature, low sodium level of the PHTS, high subassembly exit temperature, and low PHTS pump load. - Reactor coolant system integrity: The variables are PHTS sodium level, cover gas pressure, and safeguard vessel sodium level. The alarm leg is composed of low sodium level of PHTS, high cover gas pressure and high sodium level of the safety guard vessel. - PHTS heat removal: The variables are PHTS sodium level, hot pool temperature of PHTS, core exit temperature, cold pool temperature of the PHTS, flow rate of passive residual heat removal system, flow rate of active residual heat removal system, and temperatures of air heat exchanger temperature of residual heat removal systems. The alarm legs are composed of two legs of a 'passive residual heat removal system not cooling' and 'active residual heat removal system not cooling'. - Sodium water reaction mitigation: The variables are intermediate heat transfer system(IHTS) pressure, pressure and temperature and level of sodium dump tank, the status of rupture disk, hydrogen concentration in IHTS and direct variable of sodium-water-reaction measure. The alarm leg consists of high IHTS pressure, the status of sodium water reaction mitigation system and the indication of direct measure. - Radiation control: The variables are radiation of PHTS, radiation of IHTS, and radiation of containment purge. The alarm leg is composed of high radiation of PHTS and IHTS, and containment purge system. - Containment condition: The variables are containment pressure, containment isolation status, and sodium fire. The alarm leg consists of high containment pressure, status of containment isolation and status of sodium fire. (authors)« less
An intelligent surveillance platform for large metropolitan areas with dense sensor deployment.
Fernández, Jorge; Calavia, Lorena; Baladrón, Carlos; Aguiar, Javier M; Carro, Belén; Sánchez-Esguevillas, Antonio; Alonso-López, Jesus A; Smilansky, Zeev
2013-06-07
This paper presents an intelligent surveillance platform based on the usage of large numbers of inexpensive sensors designed and developed inside the European Eureka Celtic project HuSIMS. With the aim of maximizing the number of deployable units while keeping monetary and resource/bandwidth costs at a minimum, the surveillance platform is based on the usage of inexpensive visual sensors which apply efficient motion detection and tracking algorithms to transform the video signal in a set of motion parameters. In order to automate the analysis of the myriad of data streams generated by the visual sensors, the platform's control center includes an alarm detection engine which comprises three components applying three different Artificial Intelligence strategies in parallel. These strategies are generic, domain-independent approaches which are able to operate in several domains (traffic surveillance, vandalism prevention, perimeter security, etc.). The architecture is completed with a versatile communication network which facilitates data collection from the visual sensors and alarm and video stream distribution towards the emergency teams. The resulting surveillance system is extremely suitable for its deployment in metropolitan areas, smart cities, and large facilities, mainly because cheap visual sensors and autonomous alarm detection facilitate dense sensor network deployments for wide and detailed coverage.
A Design of a Surgical Site Verification System.
Shen, Biyu; He, Yan; Chen, Haoyang
2017-01-01
Patient security is a significant issue in medical research and clinical practice at present. The Surgical Verification System (Patent Number: ZL 201420079273.5) is designed to recognize and check surgical sites of patients so as to ensure operation security and decrease the risk for practitioners. Composition: (1) Operating Room Server, (2) Label Reader, (3) E-Label, (4) Surgical Site Display, (5) Ward Client, (6) Label Rader-Writer, and (7) Acousto-Optic Alarm. If the Surgical identification, the surgical site, and so on are incorrect, a flashing label control will appear when the alarm rings. You can specify a sound to play for the alarm, a picture to draw, and a message to send. It is a user-friendly system.
Chivers, Douglas P; Wisenden, Brian D; Hindman, Carrie J; Michalak, Tracy A; Kusch, Robin C; Kaminskyj, Susan G W; Jack, Kristin L; Ferrari, Maud C O; Pollock, Robyn J; Halbgewachs, Colin F; Pollock, Michael S; Alemadi, Shireen; James, Clayton T; Savaloja, Rachel K; Goater, Cameron P; Corwin, Amber; Mirza, Reehan S; Kiesecker, Joseph M; Brown, Grant E; Adrian, James C; Krone, Patrick H; Blaustein, Andrew R; Mathis, Alicia
2007-10-22
Many fishes possess specialized epidermal cells that are ruptured by the teeth of predators, thus reliably indicating the presence of an actively foraging predator. Understanding the evolution of these cells has intrigued evolutionary ecologists because the release of these alarm chemicals is not voluntary. Here, we show that predation pressure does not influence alarm cell production in fishes. Alarm cell production is stimulated by exposure to skin-penetrating pathogens (water moulds: Saprolegnia ferax and Saprolegnia parasitica), skin-penetrating parasites (larval trematodes: Teleorchis sp. and Uvulifer sp.) and correlated with exposure to UV radiation. Suppression of the immune system with environmentally relevant levels of Cd inhibits alarm cell production of fishes challenged with Saprolegnia. These data are the first evidence that alarm substance cells have an immune function against ubiquitous environmental challenges to epidermal integrity. Our results indicate that these specialized cells arose and are maintained by natural selection owing to selfish benefits unrelated to predator-prey interactions. Cell contents released when these cells are damaged in predator attacks have secondarily acquired an ecological role as alarm cues because selection favours receivers to detect and respond adaptively to public information about predation.
2007-02-01
almost identical system call sequences and triggering the same alarm at different hosts. The alarm propagation effect can be used to distinguish “true...different hosts. The alarm propagation effect can be used to distinguish “true alarms” from “false positives”. At the host-level, a new anomaly...0H ( ) ( )∑∑ = = ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ − + − = 2 1 1, 2 2 2 2 1 1 ),( ),(),()( ),( ),(),()( k m ji jiT jiTjiTiN jiT jiTjiTiNW where - marginal observed
Monitoring techniques and alarm procedures for CMS services and sites in WLCG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molina-Perez, J.; Bonacorsi, D.; Gutsche, O.
2012-01-01
The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operatingmore » worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.« less
Design of Alarm Sound of Home Care Equipment Based on Age-related Auditory Sense
NASA Astrophysics Data System (ADS)
Shibano, Jun-Ichi; Tadano, Shigeru; Kaneko, Hirotaka
A wide variety of home care equipment has been developed to support the independent lifestyle and care taking of elderly persons. Almost all of the equipment has an alarm designed to alert a care person or to sound a warning in case of an emergency. Due to the fact that aging human beings' senses physiologically, weaken and deteriorate, each alarm's sound must be designed to account for the full range of elderly person's hearing loss. Since the alarms are usually heard indoors, it is also necessary to evaluate the relationship between the basic characteristics of the sounds and living area's layout. In this study, we investigated the sounds of various alarms of the home care equipment based on both the age-related hearing characteristics of elderly persons and the propagation property of the sounds indoors. As a result, it was determined that the hearing characteristics of elderly persons are attuned to sounds which have a frequency from 700Hz to 1kHz, and it was learned that the indoor absorption ratio of sound is smallest when the frequency is 1kHz. Therefore, a frequency of 1kHz is good for the alarm sound of home care equipment. A flow chart to design the alarm sound of home care equipment was proposed, taking into account the extent of age-related auditory sense deterioration.
46 CFR 153.408 - Tank overflow control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... automatic shutdown system must: (1) Be independent of one-another; and (2) Operate on loss of power. (c) The... lettering as specified for the warning sign in § 153.955. (e) A tank overflow alarm must be audible and... loading is controlled on the tankship. (f) The automatic shutdown system or tank overflow alarm must be...
46 CFR 153.408 - Tank overflow control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... automatic shutdown system must: (1) Be independent of one-another; and (2) Operate on loss of power. (c) The... lettering as specified for the warning sign in § 153.955. (e) A tank overflow alarm must be audible and... loading is controlled on the tankship. (f) The automatic shutdown system or tank overflow alarm must be...
ERIC Educational Resources Information Center
CHANDLER, L.T.
AN EFFICIENT FIRE ALARM SYSTEM SHOULD--(1) PROVIDE WARNING OF FIRES THAT START IN HIDDEN OR UNOCCUPIED LOCATIONS, (2) INDICATE WHERE THE FIRE IS, (3) GIVE ADVANCE WARNING TO FACULTY AND ADMINISTRATION SO THAT PANIC AND CONFUSION CAN BE AVOIDED AND ORDERLY EVACUATION OCCUR, (4) AUTOMATICALLY NOTIFY CITY FIRE HEADQUARTERS OF THE FIRE, (5) OPERATE BY…
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...