Sample records for alarm threshold evaluation

  1. Alarm characterization for continuous glucose monitors used as adjuncts to self-monitoring of blood glucose.

    PubMed

    McGarraugh, Geoffrey

    2010-01-01

    Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG). Alarm evaluation in the Clinical and Laboratory Standards Institute (CLSI) guideline for CGM does not specifically address devices that employ both CGM and SMBG. In this report, an alarm evaluation method is proposed for these devices. The proposed method builds on the CLSI method using data from an in-clinic study of subjects with type 1 diabetes. CGM was used to detect glycemic events, and SMBG was used to determine treatment. To optimize detection of a single glucose level, such as 70 mg/dl, a range of alarm threshold settings was evaluated. The alarm characterization provides a choice of alarm settings that trade off detection and false alarms. Detection of a range of high glucose levels was similarly evaluated. Using low glucose alarms, detection of 70 mg/dl within 30 minutes increased from 64 to 97% as alarm settings increased from 70 to 100 mg/dl, and alarms that did not require treatment (SMBG >85 mg/dl) increased from 18 to 52%. Using high glucose alarms, detection of 180 mg/dl within 30 minutes increased from 87 to 96% as alarm settings decreased from 180 to 165 mg/dl, and alarms that did not require treatment (SMBG <180 mg/dl) increased from 24 to 42%. The proposed alarm evaluation method provides information for choosing appropriate alarm thresholds and reflects the clinical utility of CGM alarms. 2010 Diabetes Technology Society.

  2. Estimating Alarm Thresholds for Process Monitoring Data under Different Assumptions about the Data Generating Mechanism

    DOE PAGES

    Burr, Tom; Hamada, Michael S.; Howell, John; ...

    2013-01-01

    Process monitoring (PM) for nuclear safeguards sometimes requires estimation of thresholds corresponding to small false alarm rates. Threshold estimation dates to the 1920s with the Shewhart control chart; however, because possible new roles for PM are being evaluated in nuclear safeguards, it is timely to consider modern model selection options in the context of threshold estimation. One of the possible new PM roles involves PM residuals, where a residual is defined as residual = data − prediction. This paper reviews alarm threshold estimation, introduces model selection options, and considers a range of assumptions regarding the data-generating mechanism for PM residuals.more » Two PM examples from nuclear safeguards are included to motivate the need for alarm threshold estimation. The first example involves mixtures of probability distributions that arise in solution monitoring, which is a common type of PM. The second example involves periodic partial cleanout of in-process inventory, leading to challenging structure in the time series of PM residuals.« less

  3. Long-term monitoring of cardiorespiratory patterns in drug-resistant epilepsy.

    PubMed

    Goldenholz, Daniel M; Kuhn, Amanda; Austermuehle, Alison; Bachler, Martin; Mayer, Christopher; Wassertheurer, Siegfried; Inati, Sara K; Theodore, William H

    2017-01-01

    Sudden unexplained death in epilepsy (SUDEP) during inpatient electroencephalography (EEG) monitoring has been a rare but potentially preventable event, with associated cardiopulmonary markers. To date, no systematic evaluation of alarm settings for a continuous pulse oximeter (SpO 2 ) has been performed. In addition, evaluation of the interrelationship between the ictal and interictal states for cardiopulmonary measures has not been reported. Patients with epilepsy were monitored using video-EEG, SpO 2 , and electrocardiography (ECG). Alarm thresholds were tested systematically, balancing the number of false alarms with true seizure detections. Additional cardiopulmonary patterns were explored using automated ECG analysis software. One hundred ninety-three seizures (32 generalized) were evaluated from 45 patients (7,104 h recorded). Alarm thresholds of 80-86% SpO 2 detected 63-73% of all generalized convulsions and 20-28% of all focal seizures (81-94% of generalized and 25-36% of focal seizures when considering only evaluable data). These same thresholds resulted in 25-146 min between false alarms. The sequential probability of ictal SpO 2 revealed a potential common seizure termination pathway of desaturation. A statistical model of corrected QT intervals (QTc), heart rate (HR), and SpO 2 revealed close cardiopulmonary coupling ictally. Joint probability maps of QTc and SpO 2 demonstrated that many patients had baseline dysfunction in either cardiac, pulmonary, or both domains, and that ictally there was dissociation-some patients exhibited further dysfunction in one or both domains. Optimal selection of continuous pulse oximetry thresholds involves a tradeoff between seizure detection accuracy and false alarm frequency. Alarming at 86% for patients that tend to have fewer false alarms and at 80% for those who have more, would likely result in a reasonable tradeoff. The cardiopulmonary findings may lead to SUDEP biomarkers and early seizure termination therapies. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  4. Threshold Assessment of Gear Diagnostic Tools on Flight and Test Rig Data

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Mosher, Marianne; Huff, Edward M.

    2003-01-01

    A method for defining thresholds for vibration-based algorithms that provides the minimum number of false alarms while maintaining sensitivity to gear damage was developed. This analysis focused on two vibration based gear damage detection algorithms, FM4 and MSA. This method was developed using vibration data collected during surface fatigue tests performed in a spur gearbox rig. The thresholds were defined based on damage progression during tests with damage. The thresholds false alarm rates were then evaluated on spur gear tests without damage. Next, the same thresholds were applied to flight data from an OH-58 helicopter transmission. Results showed that thresholds defined in test rigs can be used to define thresholds in flight to correctly classify the transmission operation as normal.

  5. An Ethnographic Observational Study to Evaluate and Optimize the Use of Respiratory Acoustic Monitoring in Children Receiving Postoperative Opioid Infusions.

    PubMed

    Görges, Matthias; West, Nicholas C; Christopher, Nancy A; Koch, Jennifer L; Brodie, Sonia M; Lowlaavar, Nasim; Lauder, Gillian R; Ansermino, J Mark

    2016-04-01

    Respiratory depression in children receiving postoperative opioid infusions is a significant risk because of the interindividual variability in analgesic requirement. Detection of respiratory depression (or apnea) in these children may be improved with the introduction of automated acoustic respiratory rate (RR) monitoring. However, early detection of adverse events must be balanced with the risk of alarm fatigue. Our objective was to evaluate the use of acoustic RR monitoring in children receiving opioid infusions on a postsurgical ward and identify the causes of false alarm and optimal alarm thresholds. A video ethnographic study was performed using an observational, mixed methods approach. After surgery, an acoustic RR sensor was placed on the participant's neck and attached to a Rad87 monitor. The monitor was networked with paging for alarms. Vital signs data and paging notification logs were obtained from the central monitoring system. Webcam videos of the participant, infusion pump, and Rad87 monitor were recorded, stored on a secure server, and subsequently analyzed by 2 research nurses to identify the cause of the alarm, response, and effectiveness. Alarms occurring within a 90-second window were grouped into a single-alarm response opportunity. Data from 49 patients (30 females) with median age 14 (range, 4.4-18.8) years were analyzed. The 896 bedside vital sign threshold alarms resulted in 160 alarm response opportunities (44 low RR, 74 high RR, and 42 low SpO2). In 141 periods (88% of total), for which video was available, 65% of alarms were deemed effective (followed by an alarm-related action within 10 minutes). Nurses were the sole responders in 55% of effective alarms and the patient or parent in 20%. Episodes of desaturation (SpO2 < 90%) were observed in 9 patients: At the time of the SpO2 paging trigger, the RR was >10 bpm in 6 of 9 patients. Based on all RR samples observed, the default alarm thresholds, to serve as a starting point for each patient, would be a low RR of 6 (>10 years of age) and 10 (4-9 years of age). In this study, the use of RR monitoring did not improve the detection of respiratory depression. An RR threshold, which would have been predictive of desaturations, would have resulted in an unacceptably high false alarm rate. Future research using a combination of variables (e.g., SpO2 and RR), or the measurement of tidal volumes, may be needed to improve patient safety in the postoperative ward.

  6. Strategies for Managing Smart Pump Alarm and Alert Fatigue: A Narrative Review.

    PubMed

    Shah, Parth K; Irizarry, Jamie; O'Neill, Sean

    2018-06-08

    Although smart infusion pumps are intended to prevent medication errors by alerting users about doses that exceed set thresholds, a large number of clinically insignificant alarms and alerts create the potential for alert and alarm fatigue. We searched the PubMed, Scopus, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases for peer-reviewed literature (January 1, 2004-August 31, 2017) on managing smart pump alerts, alarms, and related fatigue. Twenty-nine articles that met the inclusion criteria were reviewed and organized into themes. Smart pumps give users two types of signals: alarms that indicate mechanical issues such as occlusion, air in the line, or low battery; and clinical alerts that indicate that a programmed dose exceeds a predefined safety limit. Mechanical alarms occur with greater frequency than clinical alerts, but alarms and alerts vary widely by pump model, patient population, time of day, month, and type of drug. Several causes of clinically insignificant alerts and alarms may be actionable, and strategies proposed in the literature include development of a multidisciplinary team to oversee the quality improvement effort with involvement of end users, standardization of medication administration practices, widening of drug limit library thresholds when clinically appropriate, maintaining up-to-date drug limit libraries, and interoperability. Whereas many strategies have been proposed, and case studies have been reported, none have been rigorously evaluated. In addition, more research is needed related to managing occlusion and air-in-line alarms, especially for complicated infusions. Future work should focus on the evaluation of specific and replicable alert and alarm reduction strategies with a greater emphasis on quantitative metrics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Modelling the future Israel EEWS performance using synthetic catalogue

    NASA Astrophysics Data System (ADS)

    Pinsky, V.

    2017-10-01

    In 2012 June, Israel government decided about building an Earthquake Early Warning System (EEWS) in the country. The network configuration suggested was to be a staggered line of ˜100 stations along the regional main faults: Dead Sea fault and Carmel fault and additional ˜22 stations spread over the country. The EEWS alarm system should have to utilize two approaches: the P-wave-based algorithm combined with the S-threshold method. The former utilizes first wave arrivals to several closest stations for prompt location and the three initial seconds of the waveform data for magnitude estimation. The latter issues alarm when the surface shaking (velocity or acceleration) exceeds the relatively high threshold corresponding to a magnitude 5 earthquake at a short distance of about 10 km at least for the two neighbouring stations. For each of the approaches and for a reasonable combination of them, we simulate the EEWS performance based on a synthetic catalogue. The input seismicity parameters for the processing are extracted from the real instrumental catalogue. Using a general ground-motion prediction equations for peak ground accelaration, τc and Pd we then evaluate how false and missed alarm rates depend on the corresponding thresholds. Practically, in turn, these dependencies approve choosing initial thresholds for the EEWS providing suitable false and missed alarms rates.

  8. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    PubMed

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  9. Retrospective analysis of pulse oximeter alarm settings in an intensive care unit patient population.

    PubMed

    Lansdowne, Krystal; Strauss, David G; Scully, Christopher G

    2016-01-01

    The cacophony of alerts and alarms in a hospital produced by medical devices results in alarm fatigue. The pulse oximeter is one of the most common sources of alarms. One of the ways to reduce alarm rates is to adjust alarm settings at the bedside. This study is aimed to retrospectively examine individual pulse oximeter alarm settings on alarm rates and inter- and intra- patient variability. Nine hundred sixty-two previously collected intensive care unit (ICU) patient records were obtained from the Multiparameter Intelligent Monitoring in Intensive Care II Database (Beth Israel Deaconess Medical Center, Boston, MA). Inclusion criteria included patient records that contained SpO2 trend data sampled at 1 Hz for at least 1 h and a matching clinical record. SpO2 alarm rates were simulated by applying a range of thresholds (84, 86, 88, and 90 %) and delay times (10 to 60 s) to the SpO2 data. Patient records with at least 12 h of SpO2 data were examined for the variability in alarm rate over time. Decreasing SpO2 thresholds and increasing delay times resulted in decreased alarm rates. A limited number of patient records accounted for most alarms, and this number increased as alarm settings loosened (the top 10 % of patient records were responsible for 57.4 % of all alarms at an SpO2 threshold of 90 % and 15 s delay and 81.6 % at an SpO2 threshold of 84 % and 45 s delay). Alarm rates were not consistent over time for individual patients with periods of high and low alarms for all alarm settings. Pulse oximeter SpO2 alarm rates are variable between patients and over time, and the alarm rate and the extent of inter- and intra-patient variability can be affected by the alarm settings. Personalized alarm settings for a patient's current status may help to reduce alarm fatigue for nurses.

  10. Hypoglycemia prediction with subject-specific recursive time-series models.

    PubMed

    Eren-Oruklu, Meriyan; Cinar, Ali; Quinn, Lauretta

    2010-01-01

    Avoiding hypoglycemia while keeping glucose within the narrow normoglycemic range (70-120 mg/dl) is a major challenge for patients with type 1 diabetes. Continuous glucose monitors can provide hypoglycemic alarms when the measured glucose decreases below a threshold. However, a better approach is to provide an early alarm that predicts a hypoglycemic episode before it occurs, allowing enough time for the patient to take the necessary precaution to avoid hypoglycemia. We have previously proposed subject-specific recursive models for the prediction of future glucose concentrations and evaluated their prediction performance. In this work, our objective was to evaluate this algorithm further to predict hypoglycemia and provide early hypoglycemic alarms. Three different methods were proposed for alarm decision, where (A) absolute predicted glucose values, (B) cumulative-sum (CUSUM) control chart, and (C) exponentially weighted moving-average (EWMA) control chart were used. Each method was validated using data from the Diabetes Research in Children Network, which consist of measurements from a continuous glucose sensor during an insulin-induced hypoglycemia. Reference serum glucose measurements were used to determine the sensitivity to predict hypoglycemia and the false alarm rate. With the hypoglycemic threshold set to 60 mg/dl, sensitivity of 89, 87.5, and 89% and specificity of 67, 74, and 78% were reported for methods A, B, and C, respectively. Mean values for time to detection were 30 +/- 5.51 (A), 25.8 +/- 6.46 (B), and 27.7 +/- 5.32 (C) minutes. Compared to the absolute value method, both CUSUM and EWMA methods behaved more conservatively before raising an alarm (reduced time to detection), which significantly decreased the false alarm rate and increased the specificity. 2010 Diabetes Technology Society.

  11. Alarm characterization for a continuous glucose monitor that replaces traditional blood glucose monitoring.

    PubMed

    McGarraugh, Geoffrey

    2010-01-01

    Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG); all CGM alarms require SMBG confirmation before treatment. In this report, an analysis method is proposed to determine the CGM threshold alarm accuracy required to eliminate SMBG confirmation. The proposed method builds on the Clinical and Laboratory Standards Institute (CLSI) guideline for evaluating CGM threshold alarms using data from an in-clinic study of subjects with type 1 diabetes. The CLSI method proposes a maximum time limit of +/-30 minutes for the detection of hypo- and hyperglycemic events but does not include limits for glucose measurement accuracy. The International Standards Organization (ISO) standard for SMBG glucose measurement accuracy (ISO 15197) is +/-15 mg/dl for glucose <75 mg/dl and +/-20% for glucose > or = 75 mg/dl. This standard was combined with the CLSI method to more completely characterize the accuracy of CGM alarms. Incorporating the ISO 15197 accuracy margins, FreeStyle Navigator CGM system alarms detected 70 mg/dl hypoglycemia within 30 minutes at a rate of 70.3%, with a false alarm rate of 11.4%. The device detected high glucose in the range of 140-300 mg/dl within 30 minutes at an average rate of 99.2%, with a false alarm rate of 2.1%. Self-monitoring of blood glucose confirmation is necessary for detecting and treating hypoglycemia with the FreeStyle Navigator CGM system, but at high glucose levels, SMBG confirmation adds little incremental value to CGM alarms. 2010 Diabetes Technology Society.

  12. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.

    PubMed

    McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George

    2016-07-01

    The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.

  13. Collection of annotated data in a clinical validation study for alarm algorithms in intensive care--a methodologic framework.

    PubMed

    Siebig, Sylvia; Kuhls, Silvia; Imhoff, Michael; Langgartner, Julia; Reng, Michael; Schölmerich, Jürgen; Gather, Ursula; Wrede, Christian E

    2010-03-01

    Monitoring of physiologic parameters in critically ill patients is currently performed by threshold alarm systems with high sensitivity but low specificity. As a consequence, a multitude of alarms are generated, leading to an impaired clinical value of these alarms due to reduced alertness of the intensive care unit (ICU) staff. To evaluate a new alarm procedure, we currently generate a database of physiologic data and clinical alarm annotations. Data collection is taking place at a 12-bed medical ICU. Patients with monitoring of at least heart rate, invasive arterial blood pressure, and oxygen saturation are included in the study. Numerical physiologic data at 1-second intervals, monitor alarms, and alarm settings are extracted from the surveillance network. Bedside video recordings are performed with network surveillance cameras. Based on the extracted data and the video recordings, alarms are clinically annotated by an experienced physician. The alarms are categorized according to their technical validity and clinical relevance by a taxonomy system that can be broadly applicable. Preliminary results showed that only 17% of the alarms were classified as relevant, and 44% were technically false. The presented system for collecting real-time bedside monitoring data in conjunction with video-assisted annotations of clinically relevant events is the first allowing the assessment of 24-hour periods and reduces the bias usually created by bedside observers in comparable studies. It constitutes the basis for the development and evaluation of "smart" alarm algorithms, which may help to reduce the number of alarms at the ICU, thereby improving patient safety. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Continuous glucose monitoring: quality of hypoglycaemia detection.

    PubMed

    Zijlstra, E; Heise, T; Nosek, L; Heinemann, L; Heckermann, S

    2013-02-01

    To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70 mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4 h and in case of a hypoglycaemic alarm. A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A + B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia. © 2012 Blackwell Publishing Ltd.

  15. Rainfall threshold definition using an entropy decision approach and radar data

    NASA Astrophysics Data System (ADS)

    Montesarchio, V.; Ridolfi, E.; Russo, F.; Napolitano, F.

    2011-07-01

    Flash flood events are floods characterised by a very rapid response of basins to storms, often resulting in loss of life and property damage. Due to the specific space-time scale of this type of flood, the lead time available for triggering civil protection measures is typically short. Rainfall threshold values specify the amount of precipitation for a given duration that generates a critical discharge in a given river cross section. If the threshold values are exceeded, it can produce a critical situation in river sites exposed to alluvial risk. It is therefore possible to directly compare the observed or forecasted precipitation with critical reference values, without running online real-time forecasting systems. The focus of this study is the Mignone River basin, located in Central Italy. The critical rainfall threshold values are evaluated by minimising a utility function based on the informative entropy concept and by using a simulation approach based on radar data. The study concludes with a system performance analysis, in terms of correctly issued warnings, false alarms and missed alarms.

  16. The application of machine vision in fire protection system

    NASA Astrophysics Data System (ADS)

    Rong, Jiang

    2018-04-01

    Based on the previous research, this paper introduces the theory of wavelet, collects the situation through the video system, and calculates the key information needed in the fire protection system. That is, through the algorithm to collect the information, according to the flame color characteristics and smoke characteristics were extracted, and as the characteristic information corresponding processing. Alarm system set the corresponding alarm threshold, when more than this alarm threshold, the system will alarm. This combination of flame color characteristics and smoke characteristics of the fire method not only improve the accuracy of judgment, but also improve the efficiency of judgments. Experiments show that the scheme is feasible.

  17. An entropy decision approach in flash flood warning: rainfall thresholds definition

    NASA Astrophysics Data System (ADS)

    Montesarchio, V.; Napolitano, F.; Ridolfi, E.

    2009-09-01

    Flash floods events are floods characterised by very rapid response of the basins to the storms, and often they involve loss of life and damage to common and private properties. Due to the specific space-time scale of this kind of flood, generally only a short lead time is available for triggering civil protection measures. Thresholds values specify the precipitation amount for a given duration that generates a critical discharge in a given cross section. The overcoming of these values could produce a critical situation in river sites exposed to alluvial risk, so it is possible to compare directly the observed or forecasted precipitation with critical reference values, without running on line real time forecasting systems. This study is focused on the Mignone River basin, located in Central Italy. The critical rainfall threshold values are evaluated minimising an utility function based on the informative entropy concept. The study concludes with a system performance analysis, in terms of correctly issued warning, false alarms and missed alarms.

  18. Detection and quantification system for monitoring instruments

    DOEpatents

    Dzenitis, John M [Danville, CA; Hertzog, Claudia K [Houston, TX; Makarewicz, Anthony J [Livermore, CA; Henderer, Bruce D [Livermore, CA; Riot, Vincent J [Oakland, CA

    2008-08-12

    A method of detecting real events by obtaining a set of recent signal results, calculating measures of the noise or variation based on the set of recent signal results, calculating an expected baseline value based on the set of recent signal results, determining sample deviation, calculating an allowable deviation by multiplying the sample deviation by a threshold factor, setting an alarm threshold from the baseline value plus or minus the allowable deviation, and determining whether the signal results exceed the alarm threshold.

  19. Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring.

    PubMed

    Nassi, N; Piumelli, R; Lombardi, E; Landini, L; Donzelli, G; de Martino, M

    2008-02-01

    To compare transthoracic impedance (TTI/ECG) and pulse oximetry alarm traces detected during home monitoring in infants at risk of apnoea, bradycardia and hypoxaemia. A retrospective evaluation of the monitor downloads of 67 infants who had undergone either TTI/ECG or pulse oximetry home monitoring using a device which can detect both parameters. The patients were categorised as: apparent life-threatening events (n = 39), preterm infants (n = 21) and miscellaneous (n = 7). TTI/ECG and pulse oximetry alarm traces were scored as either true or false alarms. Classification criteria were based on visual analysis of the impedance and plethysmographic waveforms captured by the memory monitor every time alarm thresholds were violated. 5242 alarms occurred over 3452 days of monitoring: 4562 (87%) were false and 680 (13%) true. The mean duration of monitoring was 51 days (range 5-220 days). There were 2982 TTI/ECG false alarms (65% of the total) and 1580 pulse oximetry false alarms (35%) (p = 0.0042). Of the 680 true alarms, 507 (74%) were desaturations not attributable to central apnoea and 173 (26%) were true TTI/ECG alarms (p = 0.0013). Comparison of pulse oximetry and TTI/ECG alarm traces shows that true events were mostly attributable to desaturations, while false alarms were mainly provoked by TTI/ECG. The total number of false alarms is lower than reported in other studies using TTI/ECG only, thus indicating that monitoring using both pulse oximetry and TTI/ECG is suitable for home use. When the combination of both techniques is not feasible or not required, we recommend the use of motion resistant pulse oximetry alone.

  20. Rainfall thresholds and susceptibility mapping for shallow landslides and debris flows in Scotland

    NASA Astrophysics Data System (ADS)

    Postance, Benjamin; Hillier, John; Dijkstra, Tom; Dixon, Neil

    2017-04-01

    Shallow translational slides and debris flows (hereafter 'landslides') pose a significant threat to life and cause significant annual economic impacts (e.g. by damage and disruption of infrastructure). The focus of this research is on the definition of objective rainfall thresholds using a weather radar system and landslide susceptibility mapping. In the study area Scotland, an inventory of 75 known landslides was used for the period 2003 to 2016. First, the effect of using different rain records (i.e. time series length) on two threshold selection techniques in receiver operating characteristic (ROC) analysis was evaluated. The results show that thresholds selected by 'Threat Score' (minimising false alarms) are sensitive to rain record length and which is not routinely considered, whereas thresholds selected using 'Optimal Point' (minimising failed alarms) are not; therefore these may be suited to establishing lower limit thresholds and be of interest to those developing early warning systems. Robust thresholds are found for combinations of normalised rain duration and accumulation at 1 and 12 day's antecedence respectively; these are normalised using the rainy-day normal and an equivalent measure for rain intensity. This research indicates that, in Scotland, rain accumulation provides a better indicator than rain intensity and that landslides may be generated by threshold conditions lower than previously thought. Second, a landslide susceptibility map is constructed using a cross-validated logistic regression model. A novel element of the approach is that landslide susceptibility is calculated for individual hillslope sections. The developed thresholds and susceptibility map are combined to assess potential hazards and impacts posed to the national highway network in Scotland.

  1. Detection and Modeling of High-Dimensional Thresholds for Fault Detection and Diagnosis

    NASA Technical Reports Server (NTRS)

    He, Yuning

    2015-01-01

    Many Fault Detection and Diagnosis (FDD) systems use discrete models for detection and reasoning. To obtain categorical values like oil pressure too high, analog sensor values need to be discretized using a suitablethreshold. Time series of analog and discrete sensor readings are processed and discretized as they come in. This task isusually performed by the wrapper code'' of the FDD system, together with signal preprocessing and filtering. In practice,selecting the right threshold is very difficult, because it heavily influences the quality of diagnosis. If a threshold causesthe alarm trigger even in nominal situations, false alarms will be the consequence. On the other hand, if threshold settingdoes not trigger in case of an off-nominal condition, important alarms might be missed, potentially causing hazardoussituations. In this paper, we will in detail describe the underlying statistical modeling techniques and algorithm as well as the Bayesian method for selecting the most likely shape and its parameters. Our approach will be illustrated by several examples from the Aerospace domain.

  2. Hypoglycemia alarm enhancement using data fusion.

    PubMed

    Skladnev, Victor N; Tarnavskii, Stanislav; McGregor, Thomas; Ghevondian, Nejhdeh; Gourlay, Steve; Jones, Timothy W

    2010-01-01

    The acceptance of closed-loop blood glucose (BG) control using continuous glucose monitoring systems (CGMS) is likely to improve with enhanced performance of their integral hypoglycemia alarms. This article presents an in silico analysis (based on clinical data) of a modeled CGMS alarm system with trained thresholds on type 1 diabetes mellitus (T1DM) patients that is augmented by sensor fusion from a prototype hypoglycemia alarm system (HypoMon). This prototype alarm system is based on largely independent autonomic nervous system (ANS) response features. Alarm performance was modeled using overnight BG profiles recorded previously on 98 T1DM volunteers. These data included the corresponding ANS response features detected by HypoMon (AiMedics Pty. Ltd.) systems. CGMS data and alarms were simulated by applying a probabilistic model to these overnight BG profiles. The probabilistic model developed used a mean response delay of 7.1 minutes, measurement error offsets on each sample of +/- standard deviation (SD) = 4.5 mg/dl (0.25 mmol/liter), and vertical shifts (calibration offsets) of +/- SD = 19.8 mg/dl (1.1 mmol/liter). Modeling produced 90 to 100 simulated measurements per patient. Alarm systems for all analyses were optimized on a training set of 46 patients and evaluated on the test set of 56 patients. The split between the sets was based on enrollment dates. Optimization was based on detection accuracy but not time to detection for these analyses. The contribution of this form of data fusion to hypoglycemia alarm performance was evaluated by comparing the performance of the trained CGMS and fused data algorithms on the test set under the same evaluation conditions. The simulated addition of HypoMon data produced an improvement in CGMS hypoglycemia alarm performance of 10% at equal specificity. Sensitivity improved from 87% (CGMS as stand-alone measurement) to 97% for the enhanced alarm system. Specificity was maintained constant at 85%. Positive predictive values on the test set improved from 61 to 66% with negative predictive values improving from 96 to 99%. These enhancements were stable within sensitivity analyses. Sensitivity analyses also suggested larger performance increases at lower CGMS alarm performance levels. Autonomic nervous system response features provide complementary information suitable for fusion with CGMS data to enhance nocturnal hypoglycemia alarms. 2010 Diabetes Technology Society.

  3. Brief communication: Using averaged soil moisture estimates to improve the performances of a regional-scale landslide early warning system

    NASA Astrophysics Data System (ADS)

    Segoni, Samuele; Rosi, Ascanio; Lagomarsino, Daniela; Fanti, Riccardo; Casagli, Nicola

    2018-03-01

    We communicate the results of a preliminary investigation aimed at improving a state-of-the-art RSLEWS (regional-scale landslide early warning system) based on rainfall thresholds by integrating mean soil moisture values averaged over the territorial units of the system. We tested two approaches. The simplest can be easily applied to improve other RSLEWS: it is based on a soil moisture threshold value under which rainfall thresholds are not used because landslides are not expected to occur. Another approach deeply modifies the original RSLEWS: thresholds based on antecedent rainfall accumulated over long periods are substituted with soil moisture thresholds. A back analysis demonstrated that both approaches consistently reduced false alarms, while the second approach reduced missed alarms as well.

  4. Detection and classification of alarm threshold violations in condition monitoring systems working in highly varying operational conditions

    NASA Astrophysics Data System (ADS)

    Strączkiewicz, M.; Barszcz, T.; Jabłoński, A.

    2015-07-01

    All commonly used condition monitoring systems (CMS) enable defining alarm thresholds that enhance efficient surveillance and maintenance of dynamic state of machinery. The thresholds are imposed on the measured values such as vibration-based indicators, temperature, pressure, etc. For complex machinery such as wind turbine (WT) the total number of thresholds might be counted in hundreds multiplied by the number of operational states. All the parameters vary not only due to possible machinery malfunctions, but also due to changes in operating conditions and these changes are typically much stronger than the former ones. Very often, such a behavior may lead to hundreds of false alarms. Therefore, authors propose a novel approach based on parameterized description of the threshold violation. For this purpose the novelty and severity factors are introduced. The first parameter refers to the time of violation occurrence while the second one describes the impact of the indicator-increase to the entire machine. Such approach increases reliability of the CMS by providing the operator with the most useful information of the system events. The idea of the procedure is presented on a simulated data similar to those from a wind turbine.

  5. Use of ambulance dispatch data as an early warning system for communitywide influenzalike illness, New York City.

    PubMed

    Mostashari, Farzad; Fine, Annie; Das, Debjani; Adams, John; Layton, Marcelle

    2003-06-01

    In 1998, the New York City Department of Health and the Mayor's Office of Emergency Management began monitoring the volume of ambulance dispatch calls as a surveillance tool for biologic terrorism. We adapted statistical techniques designed to measure excess influenza mortality and applied them to outbreak detection using ambulance dispatch data. Since 1999, we have been performing serial daily regressions to determine the alarm threshold for the current day. In this article, we evaluate this approach by simulating a series of 2,200 daily regressions. In the influenza detection implementation of this model, there were 71 (3.2%) alarms at the 99% level. Of these alarms, 64 (90%) occurred shortly before or during a period of peak influenza in each of six influenza seasons. In the bioterrorism detection implementation of this methodology, after accounting for current influenza activity, there were 24 (1.1%) alarms at the 99% level. Two occurred during a large snowstorm, 1 is unexplained, and 21 occurred shortly before or during a period of peak influenza activity in each of six influenza seasons. Our findings suggest that this surveillance system is sensitive to communitywide respiratory outbreaks with relatively few false alarms. More work needs to be done to evaluate the sensitivity of this approach for detecting nonrespiratory illness and more localized outbreaks.

  6. Recent Results on "Approximations to Optimal Alarm Systems for Anomaly Detection"

    NASA Technical Reports Server (NTRS)

    Martin, Rodney Alexander

    2009-01-01

    An optimal alarm system and its approximations may use Kalman filtering for univariate linear dynamic systems driven by Gaussian noise to provide a layer of predictive capability. Predicted Kalman filter future process values and a fixed critical threshold can be used to construct a candidate level-crossing event over a predetermined prediction window. An optimal alarm system can be designed to elicit the fewest false alarms for a fixed detection probability in this particular scenario.

  7. Organic Scintillation Detectors for Spectroscopic Radiation Portal Monitors

    NASA Astrophysics Data System (ADS)

    Paff, Marc Gerrit

    Thousands of radiation portal monitors have been deployed worldwide to detect and deter the smuggling of nuclear and radiological materials that could be used in nefarious acts. Radiation portal monitors are often installed at bottlenecks where large amounts of people or goods must traverse. Examples of use include scanning cargo containers at shipping ports, vehicles at border crossings, and people at high profile functions and events. Traditional radiation portal monitors contain separate detectors for passively measuring neutron and gamma ray count rates. 3He tubes embedded in polyethylene and slabs of plastic scintillators are the most common detector materials used in radiation portal monitors. The radiation portal monitor alarm mechanism relies on measuring radiation count rates above user defined alarm thresholds. These alarm thresholds are set above natural background count rates. Minimizing false alarms caused by natural background and maximizing sensitivity to weakly emitting threat sources must be balanced when setting these alarm thresholds. Current radiation portal monitor designs suffer from frequent nuisance radiation alarms. These radiation nuisance alarms are most frequently caused by shipments of large quantities of naturally occurring radioactive material containing cargo, like kitty litter, as well as by humans who have recently undergone a nuclear medicine procedure, particularly 99mTc treatments. Current radiation portal monitors typically lack spectroscopic capabilities, so nuisance alarms must be screened out in time-intensive secondary inspections with handheld radiation detectors. Radiation portal monitors using organic liquid scintillation detectors were designed, built, and tested. A number of algorithms were developed to perform on-the-fly radionuclide identification of single and combination radiation sources moving past the portal monitor at speeds up to 2.2 m/s. The portal monitor designs were tested extensively with a variety of shielded and unshielded radiation sources, including special nuclear material, at the European Commission Joint Research Centre in Ispra, Italy. Common medical isotopes were measured at the C.S. Mott Children's Hospital and added to the radionuclide identification algorithms.

  8. Detection of smoldering combustion of coal with an odor meter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, J.C.

    1995-05-01

    A commercially available odor meter was evaluated as a detector of smoldering coal combustion, and compared with incipient carbon monoxide (CO) and hydrogen sulfide (H{sub 2}S) detection and a commercially available ionization-type smoke detector. Ten smoldering coal combustion experiments were conducted. For eight of the experiments, Pittsburgh seam coal with an average particle diameter of approximately 5 cm was heated by embedded electrical strip heaters. For two of the experiments mine size Pittsburgh seam coal was heated. Heating rates of 0.5, 0.8, and 1.1. kw were selected to provide experimental conditions characteristic of very slow and moderately fast heating formore » coal sample mass between 3 and 10 kg. It was found that the odor meter and smoke detector alarm had a good correlation, with the odor meter alarm occurring prior to the smoke alarm in four of the ten experiments. The odor meter gave an increase in its output signal above ambient equivalent to detecting 1 ppm of H{sub 2}S (ten times the odor threshold of H{sub 2}S) as an alarm value. This observed odor meter response occurred prior to the electrochemical detection of H{sub 2}S for five of the six experiments for which it was evaluated. In all six experiments for which the smoke optical density was evaluated, it was less than 0.023 m{sup -1} prior to the odor meter reaching alarm. In each of the eight experiments with 5 cm diameter coal particles the CO exceeded 5 ppm at odor meter alarm, while for the two experiments with mine size coal the CO was less than 3 ppm at odor meter alarm. The odor meter, as tested, is not a significant improvement over smoke and CO detectors. Because the odor meter responds to a variety of chemical compounds, with suitable modification and increased sensitivity it may be useful for detection of mine fires and thereby enhance mine safety.« less

  9. Design of the intelligent smoke alarm system based on photoelectric smoke

    NASA Astrophysics Data System (ADS)

    Ma, Jiangfei; Yang, Xiufang; Wang, Peipei

    2017-02-01

    This paper designed a kind of intelligent smoke alarm system based on photoelectric smoke detector and temperature, The system takes AT89C51 MCU as the core of hardware control and Labview as the host computer monitoring center.The sensor system acquires temperature signals and smoke signals, the MCU control A/D by Sampling and converting the output analog signals , and then the two signals will be uploaded to the host computer through the serial communication. To achieve real-time monitoring of smoke and temperature in the environment, LabVIEW monitoring platform need to hold, process, analysis and display these samping signals. The intelligent smoke alarm system is suitable for large scale shopping malls and other public places, which can greatly reduce the false alarm rate of fire, The experimental results show that the system runs well and can alarm when the setting threshold is reached,and the threshold parameters can be adjusted according to the actual conditions of the field. The system is easy to operate, simple in structure, intelligent, low cost, and with strong practical value.

  10. Operational early warning of shallow landslides in Norway: Evaluation of landslide forecasts and associated challenges

    NASA Astrophysics Data System (ADS)

    Dahl, Mads-Peter; Colleuille, Hervé; Boje, Søren; Sund, Monica; Krøgli, Ingeborg; Devoli, Graziella

    2015-04-01

    The Norwegian Water Resources and Energy Directorate (NVE) runs a national early warning system (EWS) for shallow landslides in Norway. Slope failures included in the EWS are debris slides, debris flows, debris avalanches and slush flows. The EWS has been operational on national scale since 2013 and consists of (a) quantitative landslide thresholds and daily hydro-meteorological prognosis; (b) daily qualitative expert evaluation of prognosis / additional data in decision to determine warning levels; (c) publication of warning levels through various custom build internet platforms. The effectiveness of an EWS depends on both the quality of forecasts being issued, and the communication of forecasts to the public. In this analysis a preliminary evaluation of landslide forecasts from the Norwegian EWS within the period 2012-2014 is presented. Criteria for categorizing forecasts as correct, missed events or false alarms are discussed and concrete examples of forecasts falling into the latter two categories are presented. The evaluation show a rate of correct forecasts exceeding 90%. However correct forecast categorization is sometimes difficult, particularly due to poorly documented landslide events. Several challenges has to be met in the process of further lowering rates of missed events of false alarms in the EWS. Among others these include better implementation of susceptibility maps in landslide forecasting, more detailed regionalization of hydro-meteorological landslide thresholds, improved prognosis on precipitation, snowmelt and soil water content as well as the build-up of more experience among the people performing landslide forecasting.

  11. Improved detection and false alarm rejection for chemical vapors using passive hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Marinelli, William J.; Miyashiro, Rex; Gittins, Christopher M.; Konno, Daisei; Chang, Shing; Farr, Matt; Perkins, Brad

    2013-05-01

    Two AIRIS sensors were tested at Dugway Proving Grounds against chemical agent vapor simulants. The primary objectives of the test were to: 1) assess performance of algorithm improvements designed to reduce false alarm rates with a special emphasis on solar effects, and 3) evaluate performance in target detection at 5 km. The tests included 66 total releases comprising alternating 120 kg glacial acetic acid (GAA) and 60 kg triethyl phosphate (TEP) events. The AIRIS sensors had common algorithms, detection thresholds, and sensor parameters. The sensors used the target set defined for the Joint Service Lightweight Chemical Agent Detector (JSLSCAD) with TEP substituted for GA and GAA substituted for VX. They were exercised at two sites located at either 3 km or 5 km from the release point. Data from the tests will be presented showing that: 1) excellent detection capability was obtained at both ranges with significantly shorter alarm times at 5 km, 2) inter-sensor comparison revealed very comparable performance, 3) false alarm rates < 1 incident per 10 hours running time over 143 hours of sensor operations were achieved, 4) algorithm improvements eliminated both solar and cloud false alarms. The algorithms enabling the improved false alarm rejection will be discussed. The sensor technology has recently been extended to address the problem of detection of liquid and solid chemical agents and toxic industrial chemical on surfaces. The phenomenology and applicability of passive infrared hyperspectral imaging to this problem will be discussed and demonstrated.

  12. Generalised form of a power law threshold function for rainfall-induced landslides

    NASA Astrophysics Data System (ADS)

    Cepeda, Jose; Díaz, Manuel Roberto; Nadim, Farrokh; Høeg, Kaare; Elverhøi, Anders

    2010-05-01

    The following new function is proposed for estimating thresholds for rainfall-triggered landslides: I = α1Anα2Dβ, where I is rainfall intensity in mm/h, D is rainfall duration in h, An is the n-hours or n-days antecedent precipitation, and α1, α2, β and n are threshold parameters. A threshold model that combines two functions with different durations of antecedent precipitation is also introduced. A storm observation exceeds the threshold when the storm parameters are located at or above the two functions simultaneously. A novel optimisation procedure for estimating the threshold parameters is proposed using Receiver Operating Characteristics (ROC) analysis. The new threshold function and optimisation procedure are applied for estimating thresholds for triggering of debris flows in the Western Metropolitan Area of San Salvador (AMSS), El Salvador, where up to 500 casualties were produced by a single event. The resulting thresholds are I = 2322 A7d-1D-0.43 and I = 28534 A150d-1D-0.43 for debris flows having volumes greater than 3000 m3. Thresholds are also derived for debris flows greater than 200 000 m3 and for hyperconcentrated flows initiating in burned areas caused by forest fires. The new thresholds show an improved performance compared to the traditional formulations, indicated by a reduction in false alarms from 51 to 5 for the 3000 m3 thresholds and from 6 to 0 false alarms for the 200 000 m3 thresholds.

  13. Alarm systems detect volcanic tremor and earthquake swarms during Redoubt eruption, 2009

    NASA Astrophysics Data System (ADS)

    Thompson, G.; West, M. E.

    2009-12-01

    We ran two alarm algorithms on real-time data from Redoubt volcano during the 2009 crisis. The first algorithm was designed to detect escalations in continuous seismicity (tremor). This is implemented within an application called IceWeb which computes reduced displacement, and produces plots of reduced displacement and spectrograms linked to the Alaska Volcano Observatory internal webpage every 10 minutes. Reduced displacement is a measure of the amplitude of volcanic tremor, and is computed by applying a geometrical spreading correction to a displacement seismogram. When the reduced displacement at multiple stations exceeds pre-defined thresholds and there has been a factor of 3 increase in reduced displacement over the previous hour, a tremor alarm is declared. The second algorithm was to designed to detect earthquake swarms. The mean and median event rates are computed every 5 minutes based on the last hour of data from a real-time event catalog. By comparing these with thresholds, three swarm alarm conditions can be declared: a new swarm, an escalation in a swarm, and the end of a swarm. The end of swarm alarm is important as it may mark a transition from swarm to continuous tremor. Alarms from both systems were dispatched using a generic alarm management system which implements a call-down list, allowing observatory scientists to be called in sequence until someone acknowledged the alarm via a confirmation web page. The results of this simple approach are encouraging. The tremor alarm algorithm detected 26 of the 27 explosive eruptions that occurred from 23 March - 4 April. The swarm alarm algorithm detected all five of the main volcanic earthquake swarm episodes which occurred during the Redoubt crisis on 26-27 February, 21-23 March, 26 March, 2-4 April and 3-7 May. The end-of-swarm alarms on 23 March and 4 April were particularly helpful as they were caused by transitions from swarm to tremor shortly preceding explosive eruptions; transitions which were detected much earlier by the swarm algorithm than they were by the tremor algorithm.

  14. Influence of infectious disease seasonality on the performance of the outbreak detection algorithm in the China Infectious Disease Automated-alert and Response System

    PubMed Central

    Wang, Ruiping; Jiang, Yonggen; Guo, Xiaoqin; Wu, Yiling; Zhao, Genming

    2017-01-01

    Objective The Chinese Center for Disease Control and Prevention developed the China Infectious Disease Automated-alert and Response System (CIDARS) in 2008. The CIDARS can detect outbreak signals in a timely manner but generates many false-positive signals, especially for diseases with seasonality. We assessed the influence of seasonality on infectious disease outbreak detection performance. Methods Chickenpox surveillance data in Songjiang District, Shanghai were used. The optimized early alert thresholds for chickenpox were selected according to three algorithm evaluation indexes: sensitivity (Se), false alarm rate (FAR), and time to detection (TTD). Performance of selected proper thresholds was assessed by data external to the study period. Results The optimized early alert threshold for chickenpox during the epidemic season was the percentile P65, which demonstrated an Se of 93.33%, FAR of 0%, and TTD of 0 days. The optimized early alert threshold in the nonepidemic season was P50, demonstrating an Se of 100%, FAR of 18.94%, and TTD was 2.5 days. The performance evaluation demonstrated that the use of an optimized threshold adjusted for seasonality could reduce the FAR and shorten the TTD. Conclusions Selection of optimized early alert thresholds based on local infectious disease seasonality could improve the performance of the CIDARS. PMID:28728470

  15. Influence of infectious disease seasonality on the performance of the outbreak detection algorithm in the China Infectious Disease Automated-alert and Response System.

    PubMed

    Wang, Ruiping; Jiang, Yonggen; Guo, Xiaoqin; Wu, Yiling; Zhao, Genming

    2018-01-01

    Objective The Chinese Center for Disease Control and Prevention developed the China Infectious Disease Automated-alert and Response System (CIDARS) in 2008. The CIDARS can detect outbreak signals in a timely manner but generates many false-positive signals, especially for diseases with seasonality. We assessed the influence of seasonality on infectious disease outbreak detection performance. Methods Chickenpox surveillance data in Songjiang District, Shanghai were used. The optimized early alert thresholds for chickenpox were selected according to three algorithm evaluation indexes: sensitivity (Se), false alarm rate (FAR), and time to detection (TTD). Performance of selected proper thresholds was assessed by data external to the study period. Results The optimized early alert threshold for chickenpox during the epidemic season was the percentile P65, which demonstrated an Se of 93.33%, FAR of 0%, and TTD of 0 days. The optimized early alert threshold in the nonepidemic season was P50, demonstrating an Se of 100%, FAR of 18.94%, and TTD was 2.5 days. The performance evaluation demonstrated that the use of an optimized threshold adjusted for seasonality could reduce the FAR and shorten the TTD. Conclusions Selection of optimized early alert thresholds based on local infectious disease seasonality could improve the performance of the CIDARS.

  16. Coordinated Optimization of Aircraft Routes and Locations of Ground Sensors

    DTIC Science & Technology

    2014-09-17

    d U γ P p w dw    r sr s , (6) where γ is the detection threshold determined from the following equa- tion for some given faP : ( )( ) ,fa N γ...normal with the mean Uμ 7 and variance Uσ  2 3 . Suppose, the threshold for the false alarm is faP  410 . Then, from equation (7), .γ6 7190 ; and...functions; and the joint probability of false alarm would be ( , ) faP     s s 4 4 81 2 10 10 10 whereas the joint probabil- ity of detection would

  17. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System.

    PubMed

    McGarraugh, Geoffrey; Bergenstal, Richard

    2009-03-01

    The objective of the analysis was to compare detection of hypoglycemic episodes (glucose <70 mg/dL lasting >15 min) with the FreeStyle Navigator Continuous Glucose Monitoring System (FSN-CGM) (Abbott Diabetes Care, Alameda, CA) alarms to detection with traditional finger stick testing at an average frequency of eight tests per day. The performance of FSN-CGM alarms was evaluated in a clinic setting using 58 subjects with type 1 diabetes mellitus (T1DM) monitoring interstitial glucose concentration over a 5-day period compared to reference YSI measurements (instrument manufactured by YSI, Yellow Springs, OH) at 15-min intervals. Finger stick glucose testing was evaluated in the home environment with 91 subjects with TIDM monitoring with the blood glucose meter integrated into the FreeStyle Navigator (FSN-BG) over a 20-day period. The reference was FSN-CGM with results masked from the subjects. Blood glucose values <=85 mg/dL were considered the optimal treatment level to avoid or reverse hypoglycemia. With a threshold alarm setting of 85 mg/dL, 90.6% of hypoglycemic episodes were detected within +/- 30 min by FSN-CGM in the clinic study. When the alarm was activated, YSI glucose was <= 85 mg/dL 77.2% of the time. In the home environment, the average FSN-BG testing frequency was 7.9 tests per day. Hypoglycemia was verified within +/- 30 min by FSN-BG measurements <= 85 mg/dL at a rate of 27.5%. Even with a high rate of FSN-BG testing, hypoglycemia detected by FSN-CGM was verified by patients with T1DM very infrequently. A high rate of hypoglycemia detection with a moderate rate of unnecessary alarms can be attained using FSN-CGM.

  18. Visual Confirmation of Voice Takeoff Clearance (VICON) Operational Evaluation. Volume 2. Operations and Maintenance Manual

    DTIC Science & Technology

    1981-02-01

    cabinet and the field. The momentary contacts from the switches of the control panel trigger the respective circuits in module I. This circuit then... module (approximately 40 milliamperes at 70-100 detector, filter, threshold circuit and alarm relay. A block volts) Into microwave energy at X-band...advantageous to use different N.C. Terminals. NOTE: If open circuit tamper switch is modulation frequencies on links operating within close prox

  19. Antennal olfactory responsiveness of the Texas leaf cutting ant (Hymenoptera: Formicidae) to trail pheromone and its two alarm substances

    Treesearch

    N.A. Andryszak; Thomas L. Payne; J.C. Dickens; John C. Moser; R.W. Fisher

    1990-01-01

    Electroantennograms (EAGs) were recorded from major workers, queens, and males of the Texas leaf cutting, Atta texana (Buckley) (Hymenoptera: Formicidae) in response to serial dilutions of two alarm substances, 2-heptanone and 4-methyl-3-heptanone, and its trial phermone, 4-methylpyrrole-2-carbonxylate. The lower EAG threshold for major workers...

  20. A Viola-Jones based hybrid face detection framework

    NASA Astrophysics Data System (ADS)

    Murphy, Thomas M.; Broussard, Randy; Schultz, Robert; Rakvic, Ryan; Ngo, Hau

    2013-12-01

    Improvements in face detection performance would benefit many applications. The OpenCV library implements a standard solution, the Viola-Jones detector, with a statistically boosted rejection cascade of binary classifiers. Empirical evidence has shown that Viola-Jones underdetects in some instances. This research shows that a truncated cascade augmented by a neural network could recover these undetected faces. A hybrid framework is constructed, with a truncated Viola-Jones cascade followed by an artificial neural network, used to refine the face decision. Optimally, a truncation stage that captured all faces and allowed the neural network to remove the false alarms is selected. A feedforward backpropagation network with one hidden layer is trained to discriminate faces based upon the thresholding (detection) values of intermediate stages of the full rejection cascade. A clustering algorithm is used as a precursor to the neural network, to group significant overlappings. Evaluated on the CMU/VASC Image Database, comparison with an unmodified OpenCV approach shows: (1) a 37% increase in detection rates if constrained by the requirement of no increase in false alarms, (2) a 48% increase in detection rates if some additional false alarms are tolerated, and (3) an 82% reduction in false alarms with no reduction in detection rates. These results demonstrate improved face detection and could address the need for such improvement in various applications.

  1. Real-Time Continuous Response Spectra Exceedance Calculation Displayed in a Web-Browser Enables Rapid and Robust Damage Evaluation by First Responders

    NASA Astrophysics Data System (ADS)

    Franke, M.; Skolnik, D. A.; Harvey, D.; Lindquist, K.

    2014-12-01

    A novel and robust approach is presented that provides near real-time earthquake alarms for critical structures at distributed locations and large facilities using real-time estimation of response spectra obtained from near free-field motions. Influential studies dating back to the 1980s identified spectral response acceleration as a key ground motion characteristic that correlates well with observed damage in structures. Thus, monitoring and reporting on exceedance of spectra-based thresholds are useful tools for assessing the potential for damage to facilities or multi-structure campuses based on input ground motions only. With as little as one strong-motion station per site, this scalable approach can provide rapid alarms on the damage status of remote towns, critical infrastructure (e.g., hospitals, schools) and points of interests (e.g., bridges) for a very large number of locations enabling better rapid decision making during critical and difficult immediate post-earthquake response actions. Details on the novel approach are presented along with an example implementation for a large energy company. Real-time calculation of PSA exceedance and alarm dissemination are enabled with Bighorn, an extension module based on the Antelope software package that combines real-time spectral monitoring and alarm capabilities with a robust built-in web display server. Antelope is an environmental data collection software package from Boulder Real Time Technologies (BRTT) typically used for very large seismic networks and real-time seismic data analyses. The primary processing engine produces continuous time-dependent response spectra for incoming acceleration streams. It utilizes expanded floating-point data representations within object ring-buffer packets and waveform files in a relational database. This leads to a very fast method for computing response spectra for a large number of channels. A Python script evaluates these response spectra for exceedance of one or more specified spectral limits, reporting any such exceedances via alarm packets that are put in the object ring-buffer for use by any alarm processes that need them. The web-display subsystem allows alert dissemination, interactive exploration, and alarm cancellation via the WWW.

  2. Ground potential rise monitor

    DOEpatents

    Allen, Zachery W [Mandan, ND; Zevenbergen, Gary A [Arvada, CO

    2012-04-03

    A device and method for detecting ground potential rise (GPR) comprising positioning a first electrode and a second electrode at a distance from each other into the earth. The voltage of the first electrode and second electrode is attenuated by an attenuation factor creating an attenuated voltage. The true RMS voltage of the attenuated voltage is determined creating an attenuated true RMS voltage. The attenuated true RMS voltage is then multiplied by the attenuation factor creating a calculated true RMS voltage. If the calculated true RMS voltage is greater than a first predetermined voltage threshold, a first alarm is enabled at a local location. If user input is received at a remote location acknowledging the first alarm, a first alarm acknowledgment signal is transmitted. The first alarm acknowledgment signal is then received at which time the first alarm is disabled.

  3. Does the architectural layout of a NICU affect alarm pressure? A comparative clinical audit of a single-family room and an open bay area NICU using a retrospective study design.

    PubMed

    Joshi, Rohan; Straaten, Henrica van; Mortel, Heidi van de; Long, Xi; Andriessen, Peter; Pul, Carola van

    2018-06-30

    To determine differences in alarm pressure between two otherwise comparable neonatal intensive care units (NICUs) differing in architectural layout-one of a single-family room (SFR) design and the other of an open bay area (OBA) design. Retrospective audit of more than 2000 patient days from each NICU cataloguing the differences in the number and duration of alarms for critical and alerting alarms, as well as the interaction of clinicians with the patient monitor. Two level 3 NICUs. A total of more than 150 000 critical and 1.2 million alerting alarms were acquired from the two NICUs. The number of audible alarms and the associated noise pollution varied considerably with the OBA NICU generating 44% more alarms per infant per day even though the SFR NICU generated 2.5 as many critical desaturation alarms per infant per day. Differences in the architectural layout of NICUs and the consequent differences in delays, thresholds and distribution systems for alarms are associated with differences in alarm pressure. © Author(s) (or their employer(s)) 2018. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

  4. Narrowband signal detection in the SETI field test

    NASA Technical Reports Server (NTRS)

    Cullers, D. Kent; Deans, Stanley R.

    1986-01-01

    Various methods for detecting narrow-band signals are evaluated. The characteristics of synchronized and unsynchronized pulses are examined. Synchronous, square law, regular pulse, and the general form detections are discussed. The CW, single pulse, synchronous, and four pulse detections are analyzed in terms of false alarm rate and threshold relative to average noise power. Techniques for saving memory and retaining sensitivity are described. Consideration is given to nondrifting CW detection, asynchronous pulse detection, interpolative and extrapolative pulse detectors, and finite and infinite pulses.

  5. Investigating the mechanisms of visually-evoked tactile sensations.

    PubMed

    McKenzie, Kirsten J; Lloyd, Donna M; Brown, Richard J; Plummer, Faye; Poliakoff, Ellen

    2012-01-01

    When attempting to detect a near-threshold signal, participants often incorrectly report the presence of a signal, particularly when a stimulus in a different modality is presented. Here we investigated the effect of prior experience of bimodal visuotactile stimuli on the rate of falsely reported touches in the presence of a light. In Experiment 1, participants made more false alarms in light-present than light-absent trials, despite having no experience of the experimental visuotactile pairing. This suggests that light-evoked false alarms are a consequence of an existing association, rather than one learned during the experiment. In Experiment 2, we sought to manipulate the strength of the association through prior training, using supra-threshold tactile stimuli that were given a high or low association with the light. Both groups still exhibited an increased number of false alarms during light-present trials, however, the low association group made significantly fewer false alarms across conditions, and there was no corresponding group difference in the number of tactile stimuli correctly identified. Thus, while training did not affect the boosting of the tactile signal by the visual stimulus, the low association training affected perceptual decision-making more generally, leading to a lower number of illusory touch reports, independent of the light. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system.

    PubMed

    McGrath, Susan P; Pyke, Joshua; Taenzer, Andreas H

    2017-06-01

    Technology advances make it possible to consider continuous acoustic respiratory rate monitoring as an integral component of physiologic surveillance systems. This study explores technical and logistical aspects of augmenting pulse oximetry-based patient surveillance systems with continuous respiratory rate monitoring and offers some insight into the impact on patient deterioration detection that may result. Acoustic respiratory rate sensors were introduced to a general care pulse oximetry-based surveillance system with respiratory rate alarms deactivated. Simulation was used after 4324 patient days to determine appropriate alarm thresholds for respiratory rate, which were then activated. Data were collected for an additional 4382 patient days. Physiologic parameters, alarm data, sensor utilization and patient/staff feedback were collected throughout the study and analyzed. No notable technical or workflow issues were observed. Sensor utilization was 57 %, with patient refusal leading reasons for nonuse (22.7 %). With respiratory rate alarm thresholds set to 6 and 40 breaths/min., the majority of nurse pager clinical notifications were triggered by low oxygen saturation values (43 %), followed by low respiratory rate values (21 %) and low pulse rate values (13 %). Mean respiratory rate collected was 16.6 ± 3.8 breaths/min. The vast majority (82 %) of low oxygen saturation states coincided with normal respiration rates of 12-20 breaths/min. Continuous respiratory rate monitoring can be successfully added to a pulse oximetry-based surveillance system without significant technical, logistical or workflow issues and is moderately well-tolerated by patients. Respiratory rate sensor alarms did not significantly impact overall system alarm burden. Respiratory rate and oxygen saturation distributions suggest adding continuous respiratory rate monitoring to a pulse oximetry-based surveillance system may not significantly improve patient deterioration detection.

  7. Rainfall thresholds for the triggering of landslides in Slovenia

    NASA Astrophysics Data System (ADS)

    Peternel, Tina; Jemec Auflič, Mateja; Rosi, Ascanio; Segoni, Samuele; Komac, Marko; Casagli, Nicola

    2017-04-01

    Both at the worldwide level and in Slovenia, precipitation and related phenomena represent one of the most important triggering factors for the occurrence of slope mass movements. In the past decade, extreme rainfall events with a very high amount of precipitation occurs in a relatively short rainfall period have become increasingly important and more frequent, that causing numerous undesirable consequences. Intense rainstorms cause flash floods and mostly trigger shallow landslides and soil slips. On the other hand, the damage of long lasting rainstorms depends on the region's adaptation and its capacity to store or infiltrate excessive water from the rain. The amount and, consequently, the intensity of daily precipitation that can cause floods in the eastern part of Slovenia is a rather common event for the north-western part of the country. Likewise, the effect of rainfall is very dependent on the prior soil moisture, periods of full soil saturation and the creation of drifts in groundwater levels due to the slow melting of snow, growing period, etc. Landslides could be identified and to some extent also prevent with better knowledge of the relation between landslides and rainfall. In this paper the definition of rainfall thresholds for rainfall-induced landslides in Slovenia is presented. The thresholds have been calculated by collecting approximately 900 landslide data and the relative rainfall amounts, which have been collected from 41 rain gauges all over the country. The thresholds have been defined by the (1) use of an existing procedure, characterized by a high degree of objectiveness and (2) software that was developed for a test site with very different geological and climatic characteristics (Tuscany, central Italy). Firstly, a single national threshold has been defined, later the country was divided into four zones, on the basis of major the river basins and a single threshold has been calculated for each of them. Validation of the calculated thresholds has been verified by the use of several statistical parameters. Equations of thresholds of each specific zone are quite different mainly due to different climate regime and the density of the rain gauge network. In general, all thresholds have good capacity of avoiding false alarms, but at the same time, some missed alarm can be expected from local threshold, while the national threshold will lead to less missed alarm. Beside the setting of a threshold system, directly usable for civil protection purposes at national scale, an additional outcome of this work is possibility of applying methodology to another region, therefore testing its degree of exportability in different geological and climatological settings.

  8. Objective definition of rainfall intensity-duration thresholds for the initiation of post-fire debris flows in southern California

    USGS Publications Warehouse

    Staley, Dennis; Kean, Jason W.; Cannon, Susan H.; Schmidt, Kevin M.; Laber, Jayme L.

    2012-01-01

    Rainfall intensity–duration (ID) thresholds are commonly used to predict the temporal occurrence of debris flows and shallow landslides. Typically, thresholds are subjectively defined as the upper limit of peak rainstorm intensities that do not produce debris flows and landslides, or as the lower limit of peak rainstorm intensities that initiate debris flows and landslides. In addition, peak rainstorm intensities are often used to define thresholds, as data regarding the precise timing of debris flows and associated rainfall intensities are usually not available, and rainfall characteristics are often estimated from distant gauging locations. Here, we attempt to improve the performance of existing threshold-based predictions of post-fire debris-flow occurrence by utilizing data on the precise timing of debris flows relative to rainfall intensity, and develop an objective method to define the threshold intensities. We objectively defined the thresholds by maximizing the number of correct predictions of debris flow occurrence while minimizing the rate of both Type I (false positive) and Type II (false negative) errors. We identified that (1) there were statistically significant differences between peak storm and triggering intensities, (2) the objectively defined threshold model presents a better balance between predictive success, false alarms and failed alarms than previous subjectively defined thresholds, (3) thresholds based on measurements of rainfall intensity over shorter duration (≤60 min) are better predictors of post-fire debris-flow initiation than longer duration thresholds, and (4) the objectively defined thresholds were exceeded prior to the recorded time of debris flow at frequencies similar to or better than subjective thresholds. Our findings highlight the need to better constrain the timing and processes of initiation of landslides and debris flows for future threshold studies. In addition, the methods used to define rainfall thresholds in this study represent a computationally simple means of deriving critical values for other studies of nonlinear phenomena characterized by thresholds.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiaro, P.J.

    A series of tests were performed at Oak Ridge National Laboratory (ORNL) to evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The ''Cricket'' is manufactured by RAD/COMM Systems Corp., which is located in Ontario, Canada. The system is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is mounted to the base of a grappler and monitors material, while the grappler's tines hold the material. It can also be used to scan material in an attempt to isolate radioactive material if an alarm occurs. Testing was performed at themore » Environmental Effects Laboratory located at ORNL and operated by the Engineering Science and Technology Division. Tests performed included the following: (1) Background stability, (2) Energy response using {sup 241}Am, {sup 137}Cs, and {sup 60}Co, (3) Surface uniformity, (4) Angular dependence, (5) Alarm actuation, (6) Alarm threshold vs. background, (7) Shielding, (8) Response to {sup 235}U, (9) Response to neutrons using unmoderated {sup 252}Cf, and (10) Response to transient radiation. This report presents a summary of the test results. Background measurements were obtained prior to the performance of each individual test.« less

  10. Negative feedback from maternal signals reduces false alarms by collectively signalling offspring.

    PubMed

    Hamel, Jennifer A; Cocroft, Reginald B

    2012-09-22

    Within animal groups, individuals can learn of a predator's approach by attending to the behaviour of others. This use of social information increases an individual's perceptual range, but can also lead to the propagation of false alarms. Error copying is especially likely in species that signal collectively, because the coordination required for collective displays relies heavily on social information. Recent evidence suggests that collective behaviour in animals is, in part, regulated by negative feedback. Negative feedback may reduce false alarms by collectively signalling animals, but this possibility has not yet been tested. We tested the hypothesis that negative feedback increases the accuracy of collective signalling by reducing the production of false alarms. In the treehopper Umbonia crassicornis, clustered offspring produce collective signals during predator attacks, advertising the predator's location to the defending mother. Mothers signal after evicting the predator, and we show that this maternal communication reduces false alarms by offspring. We suggest that maternal signals elevate offspring signalling thresholds. This is, to our knowledge, the first study to show that negative feedback can reduce false alarms by collectively behaving groups.

  11. Early warning, warning or alarm systems for natural hazards? A generic classification.

    NASA Astrophysics Data System (ADS)

    Sättele, Martina; Bründl, Michael; Straub, Daniel

    2013-04-01

    Early warning, warning and alarm systems have gained popularity in recent years as cost-efficient measures for dangerous natural hazard processes such as floods, storms, rock and snow avalanches, debris flows, rock and ice falls, landslides, flash floods, glacier lake outburst floods, forest fires and even earthquakes. These systems can generate information before an event causes loss of property and life. In this way, they mainly mitigate the overall risk by reducing the presence probability of endangered objects. These systems are typically prototypes tailored to specific project needs. Despite their importance there is no recognised system classification. This contribution classifies warning and alarm systems into three classes: i) threshold systems, ii) expert systems and iii) model-based expert systems. The result is a generic classification, which takes the characteristics of the natural hazard process itself and the related monitoring possibilities into account. The choice of the monitoring parameters directly determines the system's lead time. The classification of 52 active systems moreover revealed typical system characteristics for each system class. i) Threshold systems monitor dynamic process parameters of ongoing events (e.g. water level of a debris flow) and incorporate minor lead times. They have a local geographical coverage and a predefined threshold determines if an alarm is automatically activated to warn endangered objects, authorities and system operators. ii) Expert systems monitor direct changes in the variable disposition (e.g crack opening before a rock avalanche) or trigger events (e.g. heavy rain) at a local scale before the main event starts and thus offer extended lead times. The final alarm decision incorporates human, model and organisational related factors. iii) Model-based expert systems monitor indirect changes in the variable disposition (e.g. snow temperature, height or solar radiation that influence the occurrence probability of snow avalanches) or trigger events (e.g. heavy snow fall) to predict spontaneous hazard events in advance. They encompass regional or national measuring networks and satisfy additional demands such as the standardisation of the measuring stations. The developed classification and the characteristics, which were revealed for each class, yield a valuable input to quantifying the reliability of warning and alarm systems. Importantly, this will facilitate to compare them with well-established standard mitigation measures such as dams, nets and galleries within an integrated risk management approach.

  12. [Study of setting of ventilator volume tidal and airway pressure alarm threshold with continuous extra-sternum heart compression in cardiopulmonary resuscitation].

    PubMed

    Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang

    2013-02-01

    To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in incidence of barotraumas during CPR.

  13. A novel algorithm for reducing false arrhythmia alarms in intensive care units.

    PubMed

    Srivastava, Chandan; Sharma, Sonal; Jalali, Ali

    2016-08-01

    Alarm fatigue in intensive care units (ICU) is one of the top healthcare issues in the US. False alarms in ICU will decrease the quality of care and staff response time over the alarms. Normally, false alarm will cause desensitization of the clinical staff which leads to warnings and misleading, if the triggered alarm is true. In this study, we have proposed a multi-model ensemble approach to reduce the false alarm rate in monitoring systems. We have used 750 patient records from PhysioNet database. At First arrhythmia based features from electrocardiogram (ECG), arterial blood pressure (ABP) and photoplethysmogram (PPG) features were extracted from the records. Next, the dataset has been separated into two subsets on the basis of available features information. The first dataset (DS1) is the combination of ECG physiological, ABP and PPG features. Their correlation coefficient and p-values criteria have been applied for relevant alarm-wise feature-set selection, and random forest classifier was used for model development and validation. The threshold based approach was used on second dataset (DS2) which is the combination of arrhythmia, ABP and PPG features. The developed ensemble model is able to achieve sensitivity 83.33-100 % (average 95.56 %) being true alarms and suppress false alarms rate 66.67-89% (average 77.25%). The predictability of classifier shows the advantage to deal with unbalanced set of information, therefore overall model performance has reached to 83.96% accuracy.

  14. Wideband Communications Equipment, Ground Radio Communication, Space Comm Systems Equipment. 304X0/X4/X6. Appendix A - Task Analysis

    DTIC Science & Technology

    1990-05-01

    ALARM LAMPS A CHECK TWT POWER SUPPLY VOLTAGE AND CURRENT A ADJUST POWER ALARM THRESHOLD AND TRANSMITTER OUTPUT A CHECK HELIX MONITOR K INTERPRET AN/FRC...POWER SUPPLY A CHECK TRAVELING WAVE TUBE ( TWT ) POWER SUPPLY HELIX CURRENT AND BEAM CURRENT A CHECK TWT RF POWER OUTPUT A CHECK TRANSMITTER POWER...A ADJUST TRANSMITTER LINEARITY A CALIBRATE TRANSMIT DEVIATION AND ADJUST MODULATION AMPLIFIER A ADJUST TWT PERFORMANCE MONITOR A ADJUST TWT OUTPUT

  15. Reliability analysis and fault-tolerant system development for a redundant strapdown inertial measurement unit. [inertial platforms

    NASA Technical Reports Server (NTRS)

    Motyka, P.

    1983-01-01

    A methodology is developed and applied for quantitatively analyzing the reliability of a dual, fail-operational redundant strapdown inertial measurement unit (RSDIMU). A Markov evaluation model is defined in terms of the operational states of the RSDIMU to predict system reliability. A 27 state model is defined based upon a candidate redundancy management system which can detect and isolate a spectrum of failure magnitudes. The results of parametric studies are presented which show the effect on reliability of the gyro failure rate, both the gyro and accelerometer failure rates together, false alarms, probability of failure detection, probability of failure isolation, and probability of damage effects and mission time. A technique is developed and evaluated for generating dynamic thresholds for detecting and isolating failures of the dual, separated IMU. Special emphasis is given to the detection of multiple, nonconcurrent failures. Digital simulation time histories are presented which show the thresholds obtained and their effectiveness in detecting and isolating sensor failures.

  16. An experiment protocol for a search for radio signals of extraterrestrial intelligent origin in the presence of man-made radio frequency sources

    NASA Technical Reports Server (NTRS)

    Edelson, R. E.

    1977-01-01

    Some aspects of signal extraction in a microwave search for evidence of extraterrestrial intelligence are examined. Parametric relations are summarized which are applicable to a microwave search of constrained duration that employs FFT spectrum-analyzer receivers, with sensitivity enhancement by spectrum accumulation and detection by a threshold criterion. Three types of natural and man-made false alarms are identified, the probability of false alarm in a single data channel is computed, and the implications of false alarms for a constant-beamwidth sky survey are considered. It is shown that the key to an efficient search is the prompt and unambiguous elimination of false alarms. An experimental protocol is suggested which eliminates spurious signals primarily through procedural techniques involving antenna repointing, delayed repeated observations, and storage of particular historical parameters for suspect signals.

  17. Flight Tests of a Remaining Flying Time Prediction System for Small Electric Aircraft in the Presence of Faults

    NASA Technical Reports Server (NTRS)

    Hogge, Edward F.; Kulkarni, Chetan S.; Vazquez, Sixto L.; Smalling, Kyle M.; Strom, Thomas H.; Hill, Boyd L.; Quach, Cuong C.

    2017-01-01

    This paper addresses the problem of building trust in the online prediction of a battery powered aircraft's remaining flying time. A series of flight tests is described that make use of a small electric powered unmanned aerial vehicle (eUAV) to verify the performance of the remaining flying time prediction algorithm. The estimate of remaining flying time is used to activate an alarm when the predicted remaining time is two minutes. This notifies the pilot to transition to the landing phase of the flight. A second alarm is activated when the battery charge falls below a specified limit threshold. This threshold is the point at which the battery energy reserve would no longer safely support two repeated aborted landing attempts. During the test series, the motor system is operated with the same predefined timed airspeed profile for each test. To test the robustness of the prediction, half of the tests were performed with, and half were performed without, a simulated powertrain fault. The pilot remotely engages a resistor bank at a specified time during the test flight to simulate a partial powertrain fault. The flying time prediction system is agnostic of the pilot's activation of the fault and must adapt to the vehicle's state. The time at which the limit threshold on battery charge is reached is then used to measure the accuracy of the remaining flying time predictions. Accuracy requirements for the alarms are considered and the results discussed.

  18. The Nurse Watch: Design and Evaluation of a Smart Watch Application with Vital Sign Monitoring and Checklist Reminders

    PubMed Central

    Bang, Magnus; Solnevik, Katarina; Eriksson, Henrik

    2015-01-01

    Computerized wearable devices such as smart watches will become valuable nursing tools. This paper describes a smart-watch system developed in close collaboration with a team of nurses working in a Swedish ICU. The smart-watch system provides real-time vital-sign monitoring, threshold alarms, and to-do reminders. Additionally, a Kanban board, visualized on a multitouch screen provides an overview of completed and upcoming tasks. We describe an approach to implement automated checklist systems with smart watches and discuss aspects of importance when implementing such memory and attention support. The paper is finalized with an in-development formative evaluation of the system. PMID:26958162

  19. The Nurse Watch: Design and Evaluation of a Smart Watch Application with Vital Sign Monitoring and Checklist Reminders.

    PubMed

    Bang, Magnus; Solnevik, Katarina; Eriksson, Henrik

    Computerized wearable devices such as smart watches will become valuable nursing tools. This paper describes a smart-watch system developed in close collaboration with a team of nurses working in a Swedish ICU. The smart-watch system provides real-time vital-sign monitoring, threshold alarms, and to-do reminders. Additionally, a Kanban board, visualized on a multitouch screen provides an overview of completed and upcoming tasks. We describe an approach to implement automated checklist systems with smart watches and discuss aspects of importance when implementing such memory and attention support. The paper is finalized with an in-development formative evaluation of the system.

  20. Integrated built-in-test false and missed alarms reduction based on forward infinite impulse response & recurrent finite impulse response dynamic neural networks

    NASA Astrophysics Data System (ADS)

    Cui, Yiqian; Shi, Junyou; Wang, Zili

    2017-11-01

    Built-in tests (BITs) are widely used in mechanical systems to perform state identification, whereas the BIT false and missed alarms cause trouble to the operators or beneficiaries to make correct judgments. Artificial neural networks (ANN) are previously used for false and missed alarms identification, which has the features such as self-organizing and self-study. However, these ANN models generally do not incorporate the temporal effect of the bottom-level threshold comparison outputs and the historical temporal features are not fully considered. To improve the situation, this paper proposes a new integrated BIT design methodology by incorporating a novel type of dynamic neural networks (DNN) model. The new DNN model is termed as Forward IIR & Recurrent FIR DNN (FIRF-DNN), where its component neurons, network structures, and input/output relationships are discussed. The condition monitoring false and missed alarms reduction implementation scheme based on FIRF-DNN model is also illustrated, which is composed of three stages including model training, false and missed alarms detection, and false and missed alarms suppression. Finally, the proposed methodology is demonstrated in the application study and the experimental results are analyzed.

  1. Dual-task performance consequences of imperfect alerting associated with a cockpit display of traffic information.

    PubMed

    Wickens, Christopher; Colcombe, Angela

    2007-10-01

    Performance consequences related to integrating an imperfect alert within a complex task domain were examined in two experiments. Cockpit displays of traffic information (CDTIs) are being designed for use in airplane cockpits as responsibility for safe separation becomes shared between pilots and controllers. Of interest in this work is how characteristics of the alarm system such as threshold, modality, and number of alert levels impact concurrent task (flight control) performance and response to potential conflicts. Student pilots performed a tracking task analogous to flight control while simultaneously monitoring for air traffic conflicts with the aid of a CDTI alert as the threshold, modality, and level of alert was varied. As the alerting system became more prone to false alerts, pilot compliance decreased and concurrent performance improved. There was some evidence of auditory preemption with auditory alerts as the false alarm rate increased. Finally, there was no benefit to a three-level system over a two-level system. There is justification for increased false alarm rates, as miss-prone systems appear to be costly. The 4:1 false alarm to miss ratio employed here improved accuracy and concurrent task performance. More research needs to address the potential benefits of likelihood alerting. The issues addressed in this research can be applied to any imperfect alerting system such as in aviation, driving, or air traffic control. It is crucial to understand the performance consequences of new technology and the efficacy of potential mitigating design features within the specific context desired.

  2. Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Keller, Jonathan A.; Wade, Daniel R.

    2008-01-01

    Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

  3. Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Keller, Jonathan A.; Wade, Daniel R.

    2009-01-01

    Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

  4. Estimation of a Constant False Alarm Rate Processing Loss for a High-Resolution Maritime Radar System

    DTIC Science & Technology

    2008-08-01

    a sample with clutter of mean level y0 and noise of variance σ 2, with a threshold CACA zt β= . Using the results presented in [15, 16, 23], it can...level y0 and noise of variance σ 2, with a threshold CACA zt β= . Using (3.107) and (3.98), the expression for the expected Pd of a Swerling 2 target can

  5. Development of an adaptive failure detection and identification system for detecting aircraft control element failures

    NASA Technical Reports Server (NTRS)

    Bundick, W. Thomas

    1990-01-01

    A methodology for designing a failure detection and identification (FDI) system to detect and isolate control element failures in aircraft control systems is reviewed. An FDI system design for a modified B-737 aircraft resulting from this methodology is also reviewed, and the results of evaluating this system via simulation are presented. The FDI system performed well in a no-turbulence environment, but it experienced an unacceptable number of false alarms in atmospheric turbulence. An adaptive FDI system, which adjusts thresholds and other system parameters based on the estimated turbulence level, was developed and evaluated. The adaptive system performed well over all turbulence levels simulated, reliably detecting all but the smallest magnitude partially-missing-surface failures.

  6. Health Monitoring Survey of Bell 412EP Transmissions

    NASA Technical Reports Server (NTRS)

    Tucker, Brian E.; Dempsey, Paula J.

    2016-01-01

    Health and usage monitoring systems (HUMS) use vibration-based Condition Indicators (CI) to assess the health of helicopter powertrain components. A fault is detected when a CI exceeds its threshold value. The effectiveness of fault detection can be judged on the basis of assessing the condition of actual components from fleet aircraft. The Bell 412 HUMS-equipped helicopter is chosen for such an evaluation. A sample of 20 aircraft included 12 aircraft with confirmed transmission and gearbox faults (detected by CIs) and eight aircraft with no known faults. The associated CI data is classified into "healthy" and "faulted" populations based on actual condition and these populations are compared against their CI thresholds to quantify the probability of false alarm and the probability of missed detection. Receiver Operator Characteristic analysis is used to optimize thresholds. Based on the results of the analysis, shortcomings in the classification method are identified for slow-moving CI trends. Recommendations for improving classification using time-dependent receiver-operator characteristic methods are put forth. Finally, lessons learned regarding OEM-operator communication are presented.

  7. Method for early detection of cooling-loss events

    DOEpatents

    Bermudez, Sergio A.; Hamann, Hendrik; Marianno, Fernando J.

    2015-06-30

    A method of detecting cooling-loss event early is provided. The method includes defining a relative humidity limit and change threshold for a given space, measuring relative humidity in the given space, determining, with a processing unit, whether the measured relative humidity is within the defined relative humidity limit, generating a warning in an event the measured relative humidity is outside the defined relative humidity limit and determining whether a change in the measured relative humidity is less than the defined change threshold for the given space and generating an alarm in an event the change is greater than the defined change threshold.

  8. Method for early detection of cooling-loss events

    DOEpatents

    Bermudez, Sergio A.; Hamann, Hendrik F.; Marianno, Fernando J.

    2015-12-22

    A method of detecting cooling-loss event early is provided. The method includes defining a relative humidity limit and change threshold for a given space, measuring relative humidity in the given space, determining, with a processing unit, whether the measured relative humidity is within the defined relative humidity limit, generating a warning in an event the measured relative humidity is outside the defined relative humidity limit and determining whether a change in the measured relative humidity is less than the defined change threshold for the given space and generating an alarm in an event the change is greater than the defined change threshold.

  9. 10 CFR 74.4 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... sequential performances of a material control test which is designed to detect anomalies potentially... capability required by § 74.53. Material control test means a comparison of a pre-established alarm threshold... into practical application for experimental and demonstration purposes, including the experimental...

  10. 10 CFR 74.4 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... sequential performances of a material control test which is designed to detect anomalies potentially... capability required by § 74.53. Material control test means a comparison of a pre-established alarm threshold... into practical application for experimental and demonstration purposes, including the experimental...

  11. 10 CFR 74.4 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... sequential performances of a material control test which is designed to detect anomalies potentially... capability required by § 74.53. Material control test means a comparison of a pre-established alarm threshold... into practical application for experimental and demonstration purposes, including the experimental...

  12. 10 CFR 74.4 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... sequential performances of a material control test which is designed to detect anomalies potentially... capability required by § 74.53. Material control test means a comparison of a pre-established alarm threshold... into practical application for experimental and demonstration purposes, including the experimental...

  13. 10 CFR 74.4 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... sequential performances of a material control test which is designed to detect anomalies potentially... capability required by § 74.53. Material control test means a comparison of a pre-established alarm threshold... into practical application for experimental and demonstration purposes, including the experimental...

  14. Quantitative quality assurance in a multicenter HARDI clinical trial at 3T.

    PubMed

    Zhou, Xiaopeng; Sakaie, Ken E; Debbins, Josef P; Kirsch, John E; Tatsuoka, Curtis; Fox, Robert J; Lowe, Mark J

    2017-01-01

    A phantom-based quality assurance (QA) protocol was developed for a multicenter clinical trial including high angular resolution diffusion imaging (HARDI). A total of 27 3T MR scanners from 2 major manufacturers, GE (Discovery and Signa scanners) and Siemens (Trio and Skyra scanners), were included in this trial. With this protocol, agar phantoms doped to mimic relaxation properties of brain tissue are scanned on a monthly basis, and quantitative procedures are used to detect spiking and to evaluate eddy current and Nyquist ghosting artifacts. In this study, simulations were used to determine alarm thresholds for minimal acceptable signal-to-noise ratio (SNR). Our results showed that spiking artifact was the most frequently observed type of artifact. Overall, Trio scanners exhibited less eddy current distortion than GE scanners, which in turn showed less distortion than Skyra scanners. This difference was mainly caused by the different sequences used on these scanners. The SNR for phantom scans was closely correlated with the SNR from volunteers. Nearly all of the phantom measurements with artifact-free images were above the alarm threshold, suggesting that the scanners are stable longitudinally. Software upgrades and hardware replacement sometimes affected SNR substantially but sometimes did not. In light of these results, it is important to monitor longitudinal SNR with phantom QA to help interpret potential effects on in vivo measurements. Our phantom QA procedure for HARDI scans was successful in tracking scanner performance and detecting unwanted artifacts. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Quantitative Quality Assurance in a Multicenter HARDI Clinical Trial at 3T

    PubMed Central

    Zhou, Xiaopeng; Sakaie, Ken E.; Debbins, Josef P.; Kirsch, John E.; Tatsuoka, Curtis; Fox, Robert J.; Lowe, Mark J.

    2016-01-01

    A phantom-based quality assurance (QA) protocol was developed for a multicenter clinical trial including high angular resolution diffusion imaging (HARDI). A total of 27 3T MR scanners from 2 major manufacturers, GE (Discovery and Signa scanners) and Siemens (Trio and Skyra scanners), were included in this trial. With this protocol, agar phantoms doped to mimic relaxation properties of brain tissue are scanned on a monthly basis, and quantitative procedures are used to detect spiking and to evaluate eddy current and Nyquist ghosting artifacts. In this study, simulations were used to determine alarm thresholds for minimal acceptable signal-to-noise ratio (SNR). Our results showed that spiking artifact was the most frequently observed type of artifact. Overall, Trio scanners exhibited less eddy current distortion than GE scanners, which in turn showed less distortion than Skyra scanners. This difference was mainly caused by the different sequences used on these scanners. The SNR for phantom scans was closely correlated with the SNR from volunteers. Nearly all of the phantom measurements with artifact-free images were above the alarm threshold, suggesting that the scanners are stable longitudinally. Software upgrades and hardware replacement sometimes affected SNR substantially but sometimes did not. In light of these results, it is important to monitor longitudinal SNR with phantom QA to help interpret potential effects on in vivo measurements. Our phantom QA procedure for HARDI scans was successful in tracking scanner performance and detecting unwanted artifacts. PMID:27587227

  16. Multiratio fusion change detection with adaptive thresholding

    NASA Astrophysics Data System (ADS)

    Hytla, Patrick C.; Balster, Eric J.; Vasquez, Juan R.; Neuroth, Robert M.

    2017-04-01

    A ratio-based change detection method known as multiratio fusion (MRF) is proposed and tested. The MRF framework builds on other change detection components proposed in this work: dual ratio (DR) and multiratio (MR). The DR method involves two ratios coupled with adaptive thresholds to maximize detected changes and minimize false alarms. The use of two ratios is shown to outperform the single ratio case when the means of the image pairs are not equal. MR change detection builds on the DR method by including negative imagery to produce four total ratios with adaptive thresholds. Inclusion of negative imagery is shown to improve detection sensitivity and to boost detection performance in certain target and background cases. MRF further expands this concept by fusing together the ratio outputs using a routine in which detections must be verified by two or more ratios to be classified as a true changed pixel. The proposed method is tested with synthetically generated test imagery and real datasets with results compared to other methods found in the literature. DR is shown to significantly outperform the standard single ratio method. MRF produces excellent change detection results that exhibit up to a 22% performance improvement over other methods from the literature at low false-alarm rates.

  17. The Politics of Legislative Evaluations: Benefits to "Fire-Alarm" Oversight.

    ERIC Educational Resources Information Center

    Wohlstetter, Priscilla

    Evaluation practices used by state legislatures to monitor educational reform are analyzed in this paper, which focuses on the link between politics and choice of oversight strategies and evaluation methods. Two oversight strategies are compared--"police-patrol" and "fire-alarm.""Fire-alarm" oversight involves…

  18. Stand-alone tsunami alarm equipment

    NASA Astrophysics Data System (ADS)

    Katsumata, Akio; Hayashi, Yutaka; Miyaoka, Kazuki; Tsushima, Hiroaki; Baba, Toshitaka; Catalán, Patricio A.; Zelaya, Cecilia; Riquelme Vasquez, Felipe; Sanchez-Olavarria, Rodrigo; Barrientos, Sergio

    2017-05-01

    One of the quickest means of tsunami evacuation is transfer to higher ground soon after strong and long ground shaking. Ground shaking itself is a good initiator of the evacuation from disastrous tsunami. Longer period seismic waves are considered to be more correlated with the earthquake magnitude. We investigated the possible application of this to tsunami hazard alarm using single-site ground motion observation. Information from the mass media is sometimes unavailable due to power failure soon after a large earthquake. Even when an official alarm is available, multiple information sources of tsunami alert would help people become aware of the coming risk of a tsunami. Thus, a device that indicates risk of a tsunami without requiring other data would be helpful to those who should evacuate. Since the sensitivity of a low-cost MEMS (microelectromechanical systems) accelerometer is sufficient for this purpose, tsunami alarm equipment for home use may be easily realized. Amplitude of long-period (20 s cutoff) displacement was proposed as the threshold for the alarm based on empirical relationships among magnitude, tsunami height, hypocentral distance, and peak ground displacement of seismic waves. Application of this method to recent major earthquakes indicated that such equipment could effectively alert people to the possibility of tsunami.

  19. Evaluating Injury Prevention Programs: The Oklahoma City Smoke Alarm Project.

    ERIC Educational Resources Information Center

    Mallonee, Sue

    2000-01-01

    Illustrates how evaluating the Oklahoma City Smoke Alarm Project increased its success in reducing residential fire-related injuries and deaths. The program distributed and tested smoke alarms in residential dwellings and offered educational materials on fire prevention and safety. Evaluation provided sound data on program processes and outcomes,…

  20. Volumetric Security Alarm Based on a Spherical Ultrasonic Transducer Array

    NASA Astrophysics Data System (ADS)

    Sayin, Umut; Scaini, Davide; Arteaga, Daniel

    Most of the existent alarm systems depend on physical or visual contact. The detection area is often limited depending on the type of the transducer, creating blind spots. Our proposition is a truly volumetric alarm system that can detect any movement in the intrusion area, based on monitoring the change over time of the impulse response of the room, which acts as an acoustic footprint. The device depends on an omnidirectional ultrasonic transducer array emitting sweep signals to calculate the impulse response in short intervals. Any change in the room conditions is monitored through a correlation function. The sensitivity of the alarm to different objects and different environments depends on the sweep duration, sweep bandwidth, and sweep interval. Successful detection of intrusions also depends on the size of the monitoring area and requires an adjustment of emitted ultrasound power. Strong air flow affects the performance of the alarm. A method for separating moving objects from strong air flow is devised using an adaptive thresholding on the correlation function involving a series of impulse response measurements. The alarm system can be also used for fire detection since air flow sourced from heating objects differ from random nature of the present air flow. Several measurements are made to test the integrity of the alarm in rooms sizing from 834-2080m3 with irregular geometries and various objects. The proposed system can efficiently detect intrusion whilst adequate emitting power is provided.

  1. Knowledge-based tracking algorithm

    NASA Astrophysics Data System (ADS)

    Corbeil, Allan F.; Hawkins, Linda J.; Gilgallon, Paul F.

    1990-10-01

    This paper describes the Knowledge-Based Tracking (KBT) algorithm for which a real-time flight test demonstration was recently conducted at Rome Air Development Center (RADC). In KBT processing, the radar signal in each resolution cell is thresholded at a lower than normal setting to detect low RCS targets. This lower threshold produces a larger than normal false alarm rate. Therefore, additional signal processing including spectral filtering, CFAR and knowledge-based acceptance testing are performed to eliminate some of the false alarms. TSC's knowledge-based Track-Before-Detect (TBD) algorithm is then applied to the data from each azimuth sector to detect target tracks. In this algorithm, tentative track templates are formed for each threshold crossing and knowledge-based association rules are applied to the range, Doppler, and azimuth measurements from successive scans. Lastly, an M-association out of N-scan rule is used to declare a detection. This scan-to-scan integration enhances the probability of target detection while maintaining an acceptably low output false alarm rate. For a real-time demonstration of the KBT algorithm, the L-band radar in the Surveillance Laboratory (SL) at RADC was used to illuminate a small Cessna 310 test aircraft. The received radar signal wa digitized and processed by a ST-100 Array Processor and VAX computer network in the lab. The ST-100 performed all of the radar signal processing functions, including Moving Target Indicator (MTI) pulse cancelling, FFT Doppler filtering, and CFAR detection. The VAX computers performed the remaining range-Doppler clustering, beamsplitting and TBD processing functions. The KBT algorithm provided a 9.5 dB improvement relative to single scan performance with a nominal real time delay of less than one second between illumination and display.

  2. Rapid detection of pandemic influenza in the presence of seasonal influenza

    PubMed Central

    2010-01-01

    Background Key to the control of pandemic influenza are surveillance systems that raise alarms rapidly and sensitively. In addition, they must minimise false alarms during a normal influenza season. We develop a method that uses historical syndromic influenza data from the existing surveillance system 'SERVIS' (Scottish Enhanced Respiratory Virus Infection Surveillance) for influenza-like illness (ILI) in Scotland. Methods We develop an algorithm based on the weekly case ratio (WCR) of reported ILI cases to generate an alarm for pandemic influenza. From the seasonal influenza data from 13 Scottish health boards, we estimate the joint probability distribution of the country-level WCR and the number of health boards showing synchronous increases in reported influenza cases over the previous week. Pandemic cases are sampled with various case reporting rates from simulated pandemic influenza infections and overlaid with seasonal SERVIS data from 2001 to 2007. Using this combined time series we test our method for speed of detection, sensitivity and specificity. Also, the 2008-09 SERVIS ILI cases are used for testing detection performances of the three methods with a real pandemic data. Results We compare our method, based on our simulation study, to the moving-average Cumulative Sums (Mov-Avg Cusum) and ILI rate threshold methods and find it to be more sensitive and rapid. For 1% case reporting and detection specificity of 95%, our method is 100% sensitive and has median detection time (MDT) of 4 weeks while the Mov-Avg Cusum and ILI rate threshold methods are, respectively, 97% and 100% sensitive with MDT of 5 weeks. At 99% specificity, our method remains 100% sensitive with MDT of 5 weeks. Although the threshold method maintains its sensitivity of 100% with MDT of 5 weeks, sensitivity of Mov-Avg Cusum declines to 92% with increased MDT of 6 weeks. For a two-fold decrease in the case reporting rate (0.5%) and 99% specificity, the WCR and threshold methods, respectively, have MDT of 5 and 6 weeks with both having sensitivity close to 100% while the Mov-Avg Cusum method can only manage sensitivity of 77% with MDT of 6 weeks. However, the WCR and Mov-Avg Cusum methods outperform the ILI threshold method by 1 week in retrospective detection of the 2009 pandemic in Scotland. Conclusions While computationally and statistically simple to implement, the WCR algorithm is capable of raising alarms, rapidly and sensitively, for influenza pandemics against a background of seasonal influenza. Although the algorithm was developed using the SERVIS data, it has the capacity to be used at other geographic scales and for different disease systems where buying some early extra time is critical. PMID:21106071

  3. Evaluation of fire-safety programs that use 10-year smoke alarms.

    PubMed

    Jackson, Mark; Wilson, Jonathan; Akoto, Judith; Dixon, Sherry; Jacobs, David E; Ballesteros, Michael F

    2010-10-01

    The Centers for Disease Control and Prevention began funding a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in 1998. This program involves the installation of lithium-powered "10-year" smoke alarms in homes at high risk for fires and injuries. This study aimed to (1) determine among original SAIFE homes if the lithium-powered alarms were still present and functional 8-10 years after installation and (2) understand factors related to smoke alarm presence and functionality. Data on a total of 384 homes and 601 smoke alarms in five states were collected and analyzed. Only one-third of alarms were still functional; 37% of installed alarms were missing; and 30% of alarms were present, but not functioning. Alarms were less likely to be functioning if they were installed in the kitchen and if homes had a different resident at follow-up. Of the 351 alarms that were present and had a battery at the time of the evaluation, only 21% contained lithium-powered batteries. Of these, 78% were still functioning. Programs that install lithium-powered alarms should use units that have sealed-in batteries and "hush" buttons. Additionally, education should be given on smoke alarm maintenance that includes a message that batteries in these alarms should not be replaced. Lithium-powered smoke alarms should last up to 10 years if maintained properly.

  4. A Physical Model of Human Skin and Its Application for Search and Rescue

    DTIC Science & Technology

    2009-12-01

    allow iv for the development of skin detection algorithms with a high probability of detection (PD) and a low probability of false alarm ( PFA ). The...various skin colors were collected. The skin detection algorithm developed in this work had a PD as high as 0.95 with a PFA of 0.006. Skin...threshold 0 < γ < 1. . . . . . . . . . . . . 103 63. Top: Detection Image with NDSI threshold γ = 0.314 with PD = 0.95 and corresponding PFA = 0.0156

  5. Reducing False Alarms of Annual Forecast in the Central China North-South Seismic Belt by Reverse Tracing of Precursors (RTP) Using the Pattern Informatics (PI) `Hotspots'

    NASA Astrophysics Data System (ADS)

    Zhang, Shengfeng; Wu, Zhongliang; Jiang, Changsheng

    2017-06-01

    The annual consultation on the likelihood of earthquakes in the next year, the `Annual Consultation Meeting', has been one of the most important forward forecast experiments organized by the China Earthquake Administration (CEA) since the 1970s, in which annual alarm regions are identified by an expert panel considering multi-disciplinary `anomalies'. In such annual forecasts, one of the problems in need of further technical solution is its false alarms. To tackle this problem, the concept of `reverse tracing of precursors (RTP)' is used to the annual consultation, as a temporal continuation and spatial extension of the work of Z hao et al. (Pure Appl Geophys 167:783-800, 2010). The central China north-south seismic belt (in connection to the CSEP testing region) is selected as the testing region of such an approach. Applying the concept of RTP, for an annual alarm region delineated by the Annual Consultation Meeting, the distribution of `hotspots' of the pattern informatics (PI), which targets the 5-year-scale seismic hazard, is considered. The `hit', or successful forecast, of the annual seismic hazard is shown to be related to the sufficient coverage of the `hotspots' within the annual alarm region. The ratio of the areas of the `hotspots' over the whole area of the annual alarm region is thus used to identify the false alarms which have few `hotspots'. The results of the years 2004-2012 show that using a threshold of 17 % can reduce 34 % (13 among 38) of the false alarms without losing the successful hit (being 6 in that period).

  6. Monitoring and Early Warning of the 2012 Preonzo Catastrophic Rockslope Failure

    NASA Astrophysics Data System (ADS)

    Loew, Simon; Gschwind, Sophie; Keller-Signer, Alexandra; Valenti, Giorgio

    2015-04-01

    In this contribution we describe the accelerated creep stage and early warning system of a 210'000 m3 rock slope failure that occurred in May 2012 above the village of Preonzo (Swiss Alps). The very rapid failure occurred from a larger and retrogressive instability in high-grade metamorphic ortho-gneisses and amphibolites with a total volume of about 350'000 m3 located at an alpine meadow called Alpe di Roscioro. This instability showed clearly visible signs of movements since 1989 and accelerated creep with significant hydro-mechanical forcing since about 1999. Because the instability at Preonzo threatened a large industrial facility and important transport routes a cost-effective early warning system was installed in 2010. The alarm thresholds for pre-alarm, general public alarm and evacuation were derived from 10 years of continuous displacement monitoring with crack extensometers and an automated total station. These thresholds were successfully applied to evacuate the industrial facility and close important roads a few days before the catastrophic slope failure of May 15th, 2012. The rock slope failure occurred in two events, exposing a planar rupture plane dipping 42° and generating deposits in the mid-slope portion with a travel angle of 38°. Two hours after the second rockslide, the fresh colluvial deposits became reactivated in a devastating de-bris avalanche reaching the foot of the slope.

  7. Sensor Anomaly Detection in Wireless Sensor Networks for Healthcare

    PubMed Central

    Haque, Shah Ahsanul; Rahman, Mustafizur; Aziz, Syed Mahfuzul

    2015-01-01

    Wireless Sensor Networks (WSN) are vulnerable to various sensor faults and faulty measurements. This vulnerability hinders efficient and timely response in various WSN applications, such as healthcare. For example, faulty measurements can create false alarms which may require unnecessary intervention from healthcare personnel. Therefore, an approach to differentiate between real medical conditions and false alarms will improve remote patient monitoring systems and quality of healthcare service afforded by WSN. In this paper, a novel approach is proposed to detect sensor anomaly by analyzing collected physiological data from medical sensors. The objective of this method is to effectively distinguish false alarms from true alarms. It predicts a sensor value from historic values and compares it with the actual sensed value for a particular instance. The difference is compared against a threshold value, which is dynamically adjusted, to ascertain whether the sensor value is anomalous. The proposed approach has been applied to real healthcare datasets and compared with existing approaches. Experimental results demonstrate the effectiveness of the proposed system, providing high Detection Rate (DR) and low False Positive Rate (FPR). PMID:25884786

  8. Functional relationship-based alarm processing

    DOEpatents

    Corsberg, D.R.

    1987-04-13

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). 11 figs.

  9. CISN ShakeAlert: Faster Warning Information Through Multiple Threshold Event Detection in the Virtual Seismologist (VS) Early Warning Algorithm

    NASA Astrophysics Data System (ADS)

    Cua, G. B.; Fischer, M.; Caprio, M.; Heaton, T. H.; Cisn Earthquake Early Warning Project Team

    2010-12-01

    The Virtual Seismologist (VS) earthquake early warning (EEW) algorithm is one of 3 EEW approaches being incorporated into the California Integrated Seismic Network (CISN) ShakeAlert system, a prototype EEW system that could potentially be implemented in California. The VS algorithm, implemented by the Swiss Seismological Service at ETH Zurich, is a Bayesian approach to EEW, wherein the most probable source estimate at any given time is a combination of contributions from a likehihood function that evolves in response to incoming data from the on-going earthquake, and selected prior information, which can include factors such as network topology, the Gutenberg-Richter relationship or previously observed seismicity. The VS codes have been running in real-time at the Southern California Seismic Network since July 2008, and at the Northern California Seismic Network since February 2009. We discuss recent enhancements to the VS EEW algorithm that are being integrated into CISN ShakeAlert. We developed and continue to test a multiple-threshold event detection scheme, which uses different association / location approaches depending on the peak amplitudes associated with an incoming P pick. With this scheme, an event with sufficiently high initial amplitudes can be declared on the basis of a single station, maximizing warning times for damaging events for which EEW is most relevant. Smaller, non-damaging events, which will have lower initial amplitudes, will require more picks to initiate an event declaration, with the goal of reducing false alarms. This transforms the VS codes from a regional EEW approach reliant on traditional location estimation (and the requirement of at least 4 picks as implemented by the Binder Earthworm phase associator) into an on-site/regional approach capable of providing a continuously evolving stream of EEW information starting from the first P-detection. Real-time and offline analysis on Swiss and California waveform datasets indicate that the multiple-threshold approach is faster and more reliable for larger events than the earlier version of the VS codes. In addition, we provide evolutionary estimates of the probability of false alarms (PFA), which is an envisioned output stream of the CISN ShakeAlert system. The real-time decision-making approach envisioned for CISN ShakeAlert users, where users specify a threshhold PFA in addition to thresholds on peak ground motion estimates, has the potential to increase the available warning time for users with high tolerance to false alarms without compromising the needs of users with lower tolerances to false alarms.

  10. Sub-parts-per-billion level detection of dimethyl methyl phosphonate (DMMP) by quantum cascade laser photoacoustic spectroscopy.

    PubMed

    Mukherjee, Anadi; Dunayevskiy, Ilya; Prasanna, Manu; Go, Rowel; Tsekoun, Alexei; Wang, Xiaojun; Fan, Jenyu; Patel, C Kumar N

    2008-04-01

    The need for the detection of chemical warfare agents (CWAs) is no longer confined to battlefield environments because of at least one confirmed terrorist attack, the Tokyo Subway [Emerg. Infect. Dis. 5, 513 (1999)] in 1995, and a suspected, i.e., a false-alarm of a CWA in the Russell Senate Office Building [Washington Post, 9 February 2006, p. B01]. Therefore, detection of CWAs with high sensitivity and low false-alarm rates is considered an important priority for ensuring public safety. We report a minimum detection level for a CWA simulant, dimethyl methyl phosphonate (DMMP), of <0.5 ppb (parts in 10(9)) by use of a widely tunable external grating cavity quantum cascade laser and photoacoustic spectroscopy. With interferents present in Santa Monica, California street air, we demonstrate a false-alarm rate of 1:10(6) at a detection threshold of 1.6 ppb.

  11. Detection of exudates in fundus imagery using a constant false-alarm rate (CFAR) detector

    NASA Astrophysics Data System (ADS)

    Khanna, Manish; Kapoor, Elina

    2014-05-01

    Diabetic retinopathy is the leading cause of blindness in adults in the United States. The presence of exudates in fundus imagery is the early sign of diabetic retinopathy so detection of these lesions is essential in preventing further ocular damage. In this paper we present a novel technique to automatically detect exudates in fundus imagery that is robust against spatial and temporal variations of background noise. The detection threshold is adjusted dynamically, based on the local noise statics around the pixel under test in order to maintain a pre-determined, constant false alarm rate (CFAR). The CFAR detector is often used to detect bright targets in radar imagery where the background clutter can vary considerably from scene to scene and with angle to the scene. Similarly, the CFAR detector addresses the challenge of detecting exudate lesions in RGB and multispectral fundus imagery where the background clutter often exhibits variations in brightness and texture. These variations present a challenge to common, global thresholding detection algorithms and other methods. Performance of the CFAR algorithm is tested against a publicly available, annotated, diabetic retinopathy database and preliminary testing suggests that performance of the CFAR detector proves to be superior to techniques such as Otsu thresholding.

  12. Acoustic emission intrusion detector

    DOEpatents

    Carver, Donald W.; Whittaker, Jerry W.

    1980-01-01

    An intrusion detector is provided for detecting a forcible entry into a secured structure while minimizing false alarms. The detector uses a piezoelectric crystal transducer to sense acoustic emissions. The transducer output is amplified by a selectable gain amplifier to control the sensitivity. The rectified output of the amplifier is applied to a Schmitt trigger circuit having a preselected threshold level to provide amplitude discrimination. Timing circuitry is provided which is activated by successive pulses from the Schmitt trigger which lie within a selected time frame for frequency discrimination. Detected signals having proper amplitude and frequency trigger an alarm within the first complete cycle time of a detected acoustical disturbance signal.

  13. Sensory redundancy management: The development of a design methodology for determining threshold values through a statistical analysis of sensor output data

    NASA Technical Reports Server (NTRS)

    Scalzo, F.

    1983-01-01

    Sensor redundancy management (SRM) requires a system which will detect failures and reconstruct avionics accordingly. A probability density function to determine false alarm rates, using an algorithmic approach was generated. Microcomputer software was developed which will print out tables of values for the cummulative probability of being in the domain of failure; system reliability; and false alarm probability, given a signal is in the domain of failure. The microcomputer software was applied to the sensor output data for various AFT1 F-16 flights and sensor parameters. Practical recommendations for further research were made.

  14. Warning system against locomotive driving wheel flaccidity

    NASA Astrophysics Data System (ADS)

    Luo, Peng

    2014-09-01

    Causes of locomotive relaxation are discussed. Alarm system against locomotive driving wheel flaccidity is designed by means of techniques of infrared temperature measurement and Hall sensor measurement. The design scheme of the system, the principle of detecting locomotive driving wheel flaccidity with temperature and Hall sensor is introduced, threshold temperature of infrared alarm is determined. The circuit system is designed by microcontroller technology and the software is designed with the assembly language. The experiment of measuring the flaccid displacement with Hall sensor measurement is simulated. The results show that the system runs well with high reliability and low cost, which has a wide prospect of application and popularization.

  15. PT-SAFE: a software tool for development and annunciation of medical audible alarms.

    PubMed

    Bennett, Christopher L; McNeer, Richard R

    2012-03-01

    Recent reports by The Joint Commission as well as the Anesthesia Patient Safety Foundation have indicated that medical audible alarm effectiveness needs to be improved. Several recent studies have explored various approaches to improving the audible alarms, motivating the authors to develop real-time software capable of comparing such alarms. We sought to devise software that would allow for the development of a variety of audible alarm designs that could also integrate into existing operating room equipment configurations. The software is meant to be used as a tool for alarm researchers to quickly evaluate novel alarm designs. A software tool was developed for the purpose of creating and annunciating audible alarms. The alarms consisted of annunciators that were mapped to vital sign data received from a patient monitor. An object-oriented approach to software design was used to create a tool that is flexible and modular at run-time, can annunciate wave-files from disk, and can be programmed with MATLAB by the user to create custom alarm algorithms. The software was tested in a simulated operating room to measure technical performance and to validate the time-to-annunciation against existing equipment alarms. The software tool showed efficacy in a simulated operating room environment by providing alarm annunciation in response to physiologic and ventilator signals generated by a human patient simulator, on average 6.2 seconds faster than existing equipment alarms. Performance analysis showed that the software was capable of supporting up to 15 audible alarms on a mid-grade laptop computer before audio dropouts occurred. These results suggest that this software tool provides a foundation for rapidly staging multiple audible alarm sets from the laboratory to a simulation environment for the purpose of evaluating novel alarm designs, thus producing valuable findings for medical audible alarm standardization.

  16. Alarm Fatigue: Use of an Evidence-Based Alarm Management Strategy.

    PubMed

    Turmell, Jacob W; Coke, Lola; Catinella, Rachel; Hosford, Tracy; Majeski, Amy

    The purpose of this article is to describe the impact of an evidence-based alarm management strategy on patient safety. An alarm management program reduced alarms up to 30%. Evaluation of patients on continuous cardiac monitoring showed a 3.5% decrease in census. This alarm management strategy has the potential to save $136 500 and 841 hours of registered nurses' time per year. No patient harm occurred during the 2-year project.

  17. Real-time distributed fiber optic sensor for security systems: Performance, event classification and nuisance mitigation

    NASA Astrophysics Data System (ADS)

    Mahmoud, Seedahmed S.; Visagathilagar, Yuvaraja; Katsifolis, Jim

    2012-09-01

    The success of any perimeter intrusion detection system depends on three important performance parameters: the probability of detection (POD), the nuisance alarm rate (NAR), and the false alarm rate (FAR). The most fundamental parameter, POD, is normally related to a number of factors such as the event of interest, the sensitivity of the sensor, the installation quality of the system, and the reliability of the sensing equipment. The suppression of nuisance alarms without degrading sensitivity in fiber optic intrusion detection systems is key to maintaining acceptable performance. Signal processing algorithms that maintain the POD and eliminate nuisance alarms are crucial for achieving this. In this paper, a robust event classification system using supervised neural networks together with a level crossings (LCs) based feature extraction algorithm is presented for the detection and recognition of intrusion and non-intrusion events in a fence-based fiber-optic intrusion detection system. A level crossings algorithm is also used with a dynamic threshold to suppress torrential rain-induced nuisance alarms in a fence system. Results show that rain-induced nuisance alarms can be suppressed for rainfall rates in excess of 100 mm/hr with the simultaneous detection of intrusion events. The use of a level crossing based detection and novel classification algorithm is also presented for a buried pipeline fiber optic intrusion detection system for the suppression of nuisance events and discrimination of intrusion events. The sensor employed for both types of systems is a distributed bidirectional fiber-optic Mach-Zehnder (MZ) interferometer.

  18. Reducing false asystole alarms in intensive care.

    PubMed

    Dekimpe, Remi; Heldt, Thomas

    2017-07-01

    High rates of false monitoring alarms in intensive care can desensitize staff and therefore pose a significant risk to patient safety. Like other critical arrhythmia alarms, asystole alarms require immediate attention by the care providers as a true asystole event can be acutely life threatening. Here, it is illustrated that most false asystole alarms can be attributed to poor signal quality, and we propose and evaluate an algorithm to identify data windows of poor signal quality and thereby help suppress false asystole alarms. The algorithm combines intuitive signal-quality features (degree of signal saturation and baseline wander) and information from other physiological signals that might be available. Algorithm training and testing was performed on the MIMIC II and 2015 PhysioNet/Computing in Cardiology Challenge databases, respectively. The algorithm achieved an alarm specificity of 81.0% and sensitivity of 95.4%, missing only one out of 22 true asystole alarms. On a separate neonatal data set, the algorithm was able to reject 89.7% (890 out of 992) of false asystole alarms while keeping all 22 true events. The results show that the false asystole alarm rate can be significantly reduced through basic signal quality evaluation.

  19. Functional relationship-based alarm processing system

    DOEpatents

    Corsberg, D.R.

    1988-04-22

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary. 12 figs.

  20. Functional relationship-based alarm processing

    DOEpatents

    Corsberg, Daniel R.

    1988-01-01

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously oupdated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on caussal factors between two alarms); (3) required action (system response or action) expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.

  1. Functional relationship-based alarm processing system

    DOEpatents

    Corsberg, Daniel R.

    1989-01-01

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.

  2. AREA RADIATION MONITOR

    DOEpatents

    Manning, F.W.; Groothuis, S.E.; Lykins, J.H.; Papke, D.M.

    1962-06-12

    S>An improved area radiation dose monitor is designed which is adapted to compensate continuously for background radiation below a threshold dose rate and to give warning when the dose integral of the dose rate of an above-threshold radiation excursion exceeds a selected value. This is accomplished by providing means for continuously charging an ionization chamber. The chamber provides a first current proportional to the incident radiation dose rate. Means are provided for generating a second current including means for nulling out the first current with the second current at all values of the first current corresponding to dose rates below a selected threshold dose rate value. The second current has a maximum value corresponding to that of the first current at the threshold dose rate. The excess of the first current over the second current, which occurs above the threshold, is integrated and an alarm is given at a selected integrated value of the excess corresponding to a selected radiation dose. (AEC)

  3. Adaptive Spot Detection With Optimal Scale Selection in Fluorescence Microscopy Images.

    PubMed

    Basset, Antoine; Boulanger, Jérôme; Salamero, Jean; Bouthemy, Patrick; Kervrann, Charles

    2015-11-01

    Accurately detecting subcellular particles in fluorescence microscopy is of primary interest for further quantitative analysis such as counting, tracking, or classification. Our primary goal is to segment vesicles likely to share nearly the same size in fluorescence microscopy images. Our method termed adaptive thresholding of Laplacian of Gaussian (LoG) images with autoselected scale (ATLAS) automatically selects the optimal scale corresponding to the most frequent spot size in the image. Four criteria are proposed and compared to determine the optimal scale in a scale-space framework. Then, the segmentation stage amounts to thresholding the LoG of the intensity image. In contrast to other methods, the threshold is locally adapted given a probability of false alarm (PFA) specified by the user for the whole set of images to be processed. The local threshold is automatically derived from the PFA value and local image statistics estimated in a window whose size is not a critical parameter. We also propose a new data set for benchmarking, consisting of six collections of one hundred images each, which exploits backgrounds extracted from real microscopy images. We have carried out an extensive comparative evaluation on several data sets with ground-truth, which demonstrates that ATLAS outperforms existing methods. ATLAS does not need any fine parameter tuning and requires very low computation time. Convincing results are also reported on real total internal reflection fluorescence microscopy images.

  4. Cumulative detection probabilities and range accuracy of a pulsed Geiger-mode avalanche photodiode laser ranging system

    NASA Astrophysics Data System (ADS)

    Luo, Hanjun; Ouyang, Zhengbiao; Liu, Qiang; Chen, Zhiliang; Lu, Hualan

    2017-10-01

    Cumulative pulses detection with appropriate cumulative pulses number and threshold has the ability to improve the detection performance of the pulsed laser ranging system with GM-APD. In this paper, based on Poisson statistics and multi-pulses cumulative process, the cumulative detection probabilities and their influence factors are investigated. With the normalized probability distribution of each time bin, the theoretical model of the range accuracy and precision is established, and the factors limiting the range accuracy and precision are discussed. The results show that the cumulative pulses detection can produce higher target detection probability and lower false alarm probability. However, for a heavy noise level and extremely weak echo intensity, the false alarm suppression performance of the cumulative pulses detection deteriorates quickly. The range accuracy and precision is another important parameter evaluating the detection performance, the echo intensity and pulse width are main influence factors on the range accuracy and precision, and higher range accuracy and precision is acquired with stronger echo intensity and narrower echo pulse width, for 5-ns echo pulse width, when the echo intensity is larger than 10, the range accuracy and precision lower than 7.5 cm can be achieved.

  5. Personal Cabin Pressure Monitor and Warning System

    NASA Technical Reports Server (NTRS)

    Zysko, Jan A. (Inventor)

    2002-01-01

    A cabin pressure altitude monitor and warning system provides a warning when a detected cabin pressure altitude has reached a predetermined level. The system is preferably embodied in a portable, pager-sized device that can be carried or worn by an individual. A microprocessor calculates the pressure altitude from signals generated by a calibrated pressure transducer and a temperature sensor that compensates for temperature variations in the signals generated by the pressure transducer. The microprocessor is programmed to generate a warning or alarm if a cabin pressure altitude exceeding a predetermined threshold is detected. Preferably, the microprocessor generates two different types of warning or alarm outputs, a first early warning or alert when a first pressure altitude is exceeded. and a second more serious alarm condition when either a second. higher pressure altitude is exceeded, or when the first pressure altitude has been exceeded for a predetermined period of time. Multiple types of alarm condition indicators are preferably provided, including visual, audible and tactile. The system is also preferably designed to detect gas concentrations and other ambient conditions, and thus incorporates other sensors, such as oxygen, relative humidity, carbon dioxide, carbon monoxide and ammonia sensors, to provide a more complete characterization and monitoring of the local environment.

  6. Real-Time Continuous Response Spectra Exceedance Calculation

    NASA Astrophysics Data System (ADS)

    Vernon, Frank; Harvey, Danny; Lindquist, Kent; Franke, Mathias

    2017-04-01

    A novel approach is presented for near real-time earthquake alarms for critical structures at distributed locations using real-time estimation of response spectra obtained from near free-field motions. Influential studies dating back to the 1980s identified spectral response acceleration as a key ground motion characteristic that correlates well with observed damage in structures. Thus, monitoring and reporting on exceedance of spectra-based thresholds are useful tools for assessing the potential for damage to facilities or multi-structure campuses based on input ground motions only. With as little as one strong-motion station per site, this scalable approach can provide rapid alarms on the damage status of remote towns, critical infrastructure (e.g., hospitals, schools) and points of interests (e.g., bridges) for a very large number of locations enabling better rapid decision making during critical and difficult immediate post-earthquake response actions. Real-time calculation of PSA exceedance and alarm dissemination are enabled with Bighorn, a module included in the Antelope software package that combines real-time spectral monitoring and alarm capabilities with a robust built-in web display server. Examples of response spectra from several M 5 events recorded by the ANZA seismic network in southern California will be presented.

  7. Personal Cabin Pressure Monitor and Warning System

    NASA Astrophysics Data System (ADS)

    Zysko, Jan A.

    2002-09-01

    A cabin pressure altitude monitor and warning system provides a warning when a detected cabin pressure altitude has reached a predetermined level. The system is preferably embodied in a portable, pager-sized device that can be carried or worn by an individual. A microprocessor calculates the pressure altitude from signals generated by a calibrated pressure transducer and a temperature sensor that compensates for temperature variations in the signals generated by the pressure transducer. The microprocessor is programmed to generate a warning or alarm if a cabin pressure altitude exceeding a predetermined threshold is detected. Preferably, the microprocessor generates two different types of warning or alarm outputs, a first early warning or alert when a first pressure altitude is exceeded. and a second more serious alarm condition when either a second. higher pressure altitude is exceeded, or when the first pressure altitude has been exceeded for a predetermined period of time. Multiple types of alarm condition indicators are preferably provided, including visual, audible and tactile. The system is also preferably designed to detect gas concentrations and other ambient conditions, and thus incorporates other sensors, such as oxygen, relative humidity, carbon dioxide, carbon monoxide and ammonia sensors, to provide a more complete characterization and monitoring of the local environment.

  8. Evaluated community fire safety interventions in the United States: a review of current literature.

    PubMed

    Ta, Van M; Frattaroli, Shannon; Bergen, Gwendolyn; Gielen, Andrea Carlson

    2006-06-01

    The purpose of the study was to assess the state of fire prevention research, provide an updated synthesis of evaluated fire prevention programs, and discuss the role of fire fighters and data systems in prevention efforts. The review included all evaluations of U.S. based fire prevention interventions published between January 1998 and September 2004 and any earlier articles about U.S. fire prevention interventions not included in two prior review articles. We retrieved information from each identified study including evaluation findings, involvement of fire service personnel and use of existing data systems. We identified twelve articles: seven reported on smoke alarm interventions, three on multi-faceted programs, and two other programs. Five programs involved fire service personnel in the design, implementation, and/or evaluation, and three used existing data systems. Studies reviewed suggest that canvassing and smoke alarm installations are the most effective means of distributing alarms and increasing the functional status of distributed alarms. The functionality of smoke alarms, an issue noted in earlier reviews, remains a problem. Programs involving partnerships with fire departments have indicated success in preventing fires and deaths, improving smoke alarm ownership and functional status, and improving children's fire safety knowledge. Using existing data systems to target and to evaluate interventions was effective. In the years since prior reviews, some improvements in the rigor of evaluation designs have been made, but there is still a need for high quality evaluations that will inform fire injury prevention efforts.

  9. Data-based Considerations in Portal Radiation Monitoring of Cargo Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weier, Dennis R.; O'Brien, Robert F.; Ely, James H.

    2004-07-01

    Radiation portal monitoring of cargo vehicles often includes a configuration of four-panel monitors that record gamma and neutron counts from vehicles transporting cargo. As vehicles pass the portal monitors, they generate a count profile over time that can be compared to the average panel background counts obtained just prior to the time the vehicle entered the area of the monitors. Pacific Northwest National Laboratory has accumulated considerable data regarding such background radiation and vehicle profiles from portal installations, as well as in experimental settings using known sources and cargos. Several considerations have a bearing on how alarm thresholds are setmore » in order to maintain sensitivity to radioactive sources while also controlling to a manageable level the rate of false or nuisance alarms. False alarms are statistical anomalies while nuisance alarms occur due to the presence of naturally occurring radioactive material (NORM) in cargo, for example, kitty litter. Considerations to be discussed include: • Background radiation suppression due to the shadow shielding from the vehicle. • The impact of the relative placement of the four panels on alarm decision criteria. • Use of plastic scintillators to separate gamma counts into energy windows. • The utility of using ratio criteria for the energy window counts rather than simply using total window counts. • Detection likelihood for these various decision criteria based on computer simulated injections of sources into vehicle profiles.« less

  10. Infrared Instrument for Detecting Hydrogen Fires

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert; Ihlefeld, Curtis; Immer, Christopher; Oostdyk, Rebecca; Cox, Robert; Taylor, John

    2006-01-01

    The figure shows an instrument incorporating an infrared camera for detecting small hydrogen fires. The instrument has been developed as an improved replacement for prior infrared and ultraviolet instruments used to detect hydrogen fires. The need for this or any such instrument arises because hydrogen fires (e.g., those associated with leaks from tanks, valves, and ducts) pose a great danger, yet they emit so little visible light that they are mostly undetectable by the unaided human eye. The main performance advantage offered by the present instrument over prior hydrogen-fire-detecting instruments lies in its greater ability to avoid false alarms by discriminating against reflected infrared light, including that originating in (1) the Sun, (2) welding torches, and (3) deliberately ignited hydrogen flames (e.g., ullage-burn-off flames) that are nearby but outside the field of view intended to be monitored by the instrument. Like prior such instruments, this instrument is based mostly on the principle of detecting infrared emission above a threshold level. However, in addition, this instrument utilizes information on the spatial distribution of infrared light from a source that it detects. Because the combination of spatial and threshold information about a flame tends to constitute a unique signature that differs from that of reflected infrared light originating in a source not in the field of view, the incidence of false alarms is reduced substantially below that of related prior threshold- based instruments.

  11. Experiments with the Skylab fire detectors in zero gravity

    NASA Technical Reports Server (NTRS)

    Linford, R. M. F.

    1972-01-01

    The Skylab fire detector was evaluated in a zero gravity environment. To conduct the test, small samples of spacecraft materials were ignited in a 5 psi oxygen-rich atmosphere inside a combustion chamber. The chamber free-floated in the cabin of a C-135 aircraft, as the aircraft executed a Keplerian parabola. Up to 10 seconds of zero-gravity combustion were achieved. The Skylab fire-detector tubes viewed the flames from a simulated distance of 3m, and color movies were taken to record the nature of the fire. The experiments established the unique form of zero-gravity fires for a wide range of materials. From the tube-output data, the alarm threshold and detector time constant were verified for the Skylab Fire Detection System.

  12. Evaluation of Flood Forecast and Warning in Elbe river basin - Impact of Forecaster's Strategy

    NASA Astrophysics Data System (ADS)

    Danhelka, Jan; Vlasak, Tomas

    2010-05-01

    Czech Hydrometeorological Institute (CHMI) is responsible for flood forecasting and warning in the Czech Republic. To meet that issue CHMI operates hydrological forecasting systems and publish flow forecast in selected profiles. Flood forecast and warning is an output of system that links observation (flow and atmosphere), data processing, weather forecast (especially NWP's QPF), hydrological modeling and modeled outputs evaluation and interpretation by forecaster. Forecast users are interested in final output without separating uncertainties of separate steps of described process. Therefore an evaluation of final operational forecasts was done for profiles within Elbe river basin produced by AquaLog forecasting system during period 2002 to 2008. Effects of uncertainties of observation, data processing and especially meteorological forecasts were not accounted separately. Forecast of flood levels exceedance (peak over the threshold) during forecasting period was the main criterion as flow increase forecast is of the highest importance. Other evaluation criteria included peak flow and volume difference. In addition Nash-Sutcliffe was computed separately for each time step (1 to 48 h) of forecasting period to identify its change with the lead time. Textual flood warnings are issued for administrative regions to initiate flood protection actions in danger of flood. Flood warning hit rate was evaluated at regions level and national level. Evaluation found significant differences of model forecast skill between forecasting profiles, particularly less skill was evaluated at small headwater basins due to domination of QPF uncertainty in these basins. The average hit rate was 0.34 (miss rate = 0.33, false alarm rate = 0.32). However its explored spatial difference is likely to be influenced also by different fit of parameters sets (due to different basin characteristics) and importantly by different impact of human factor. Results suggest that the practice of interactive model operation, experience and forecasting strategy differs between responsible forecasting offices. Warning is based on model outputs interpretation by hydrologists-forecaster. Warning hit rate reached 0.60 for threshold set to lowest flood stage of which 0.11 was underestimation of flood degree (miss 0.22, false alarm 0.28). Critical success index of model forecast was 0.34, while the same criteria for warning reached 0.55. We assume that the increase accounts not only to change of scale from single forecasting point to region for warning, but partly also to forecaster's added value. There is no official warning strategy preferred in the Czech Republic (f.e. tolerance towards higher false alarm rate). Therefore forecaster decision and personal strategy is of great importance. Results show quite successful warning for 1st flood level exceedance, over-warning for 2nd flood level, but under-warning for 3rd (highest) flood level. That suggests general forecaster's preference of medium level warning (2nd flood level is legally determined to be the start of the flood and flood protection activities). In conclusion human forecaster's experience and analysis skill increases flood warning performance notably. However society preference should be specifically addressed in the warning strategy definition to support forecaster's decision making.

  13. Interventions for promoting smoke alarm ownership and function.

    PubMed

    DiGuiseppi, C; Higgins, J P

    2001-01-01

    Residential fires caused at least 67 deaths and 2,500 non-fatal injuries to children aged 0-16 in the United Kingdom in 1998. Smoke alarm ownership is associated with a reduced risk of residential fire death. We evaluated interventions to promote residential smoke alarms, to assess their effect on smoke alarm ownership, smoke alarm function, fires and burns and other fire-related injuries. We searched the Cochrane Controlled Trials Register, Cochrane Injuries Group database, MEDLINE, EMBASE, PsycLIT, CINAHL, ERIC, Dissertation Abstracts, International Bibliography of Social Sciences, ISTP, FIREDOC and LRC. Conference proceedings, published case studies, and bibliographies were systematically searched, and investigators and relevant organisations were contacted, to identify trials. Randomised, quasi-randomised or nonrandomised controlled trials completed or published after 1969 evaluating an intervention to promote residential smoke alarms. Two reviewers independently extracted data and assessed trial quality. We identified 26 trials, of which 13 were randomised. Overall, counselling and educational interventions had only a modest effect on the likelihood of owning an alarm (OR=1.26; 95% CI: 0.87 to 1.82) or having a functional alarm (OR=1.19; 0.85 to 1.66). Counselling as part of primary care child health surveillance had greater effects on ownership (OR=1.96; 1.03 to 3.72) and function (OR=1.72; 0.78 to 3.80). Results were sensitive to trial quality, however, and effects on fire-related injuries were not reported. In two non randomised trials, direct provision of free alarms significantly increased functioning alarms and reduced fire-related injuries. Media and community education showed little benefit in non randomised trials. Counselling as part of child health surveillance may increase smoke alarm ownership and function, but its effects on injuries are unevaluated. Community smoke alarm give-away programmes apparently reduce fire-related injuries, but these trials were not randomised and results must be interpreted cautiously. Further efforts to promote smoke alarms in primary care or through give-away programmes should be evaluated by adequately designed randomised controlled trials measuring injury outcomes.

  14. Assessment of target detection limits in hyperspectral data

    NASA Astrophysics Data System (ADS)

    Gross, W.; Boehler, J.; Schilling, H.; Middelmann, W.; Weyermann, J.; Wellig, P.; Oechslin, R.; Kneubuehler, M.

    2015-10-01

    Hyperspectral remote sensing data can be used for civil and military applications to detect and classify target objects that cannot be reliably separated using broadband sensors. The comparably low spatial resolution is compensated by the fact that small targets, even below image resolution, can still be classified. The goal of this paper is to determine the target size to spatial resolution ratio for successful classification of different target and background materials. Airborne hyperspectral data is used to simulate data with known mixture ratios and to estimate the detection threshold for given false alarm rates. The data was collected in July 2014 over Greding, Germany, using airborne aisaEAGLE and aisaHAWK hyperspectral sensors. On the ground, various target materials were placed on natural background. The targets were four quadratic molton patches with an edge length of 7 meters in the colors black, white, grey and green. Also, two different types of polyethylene (camouflage nets) with an edge length of approximately 5.5 meters were deployed. Synthetic data is generated from the original data using spectral mixtures. Target signatures are linearly combined with different background materials in specific ratios. The simulated mixtures are appended to the original data and the target areas are removed for evaluation. Commonly used classification algorithms, e.g. Matched Filtering, Adaptive Cosine Estimator are used to determine the detection limit. Fixed false alarm rates are employed to find and analyze certain regions where false alarms usually occur first. A combination of 18 targets and 12 backgrounds is analyzed for three VNIR and two SWIR data sets of the same area.

  15. Non-linear feature extraction from HRV signal for mortality prediction of ICU cardiovascular patient.

    PubMed

    Karimi Moridani, Mohammad; Setarehdan, Seyed Kamaledin; Motie Nasrabadi, Ali; Hajinasrollah, Esmaeil

    2016-01-01

    Intensive care unit (ICU) patients are at risk of in-ICU morbidities and mortality, making specific systems for identifying at-risk patients a necessity for improving clinical care. This study presents a new method for predicting in-hospital mortality using heart rate variability (HRV) collected from the times of a patient's ICU stay. In this paper, a HRV time series processing based method is proposed for mortality prediction of ICU cardiovascular patients. HRV signals were obtained measuring R-R time intervals. A novel method, named return map, is then developed that reveals useful information from the HRV time series. This study also proposed several features that can be extracted from the return map, including the angle between two vectors, the area of triangles formed by successive points, shortest distance to 45° line and their various combinations. Finally, a thresholding technique is proposed to extract the risk period and to predict mortality. The data used to evaluate the proposed algorithm obtained from 80 cardiovascular ICU patients, from the first 48 h of the first ICU stay of 40 males and 40 females. This study showed that the angle feature has on average a sensitivity of 87.5% (with 12 false alarms), the area feature has on average a sensitivity of 89.58% (with 10 false alarms), the shortest distance feature has on average a sensitivity of 85.42% (with 14 false alarms) and, finally, the combined feature has on average a sensitivity of 92.71% (with seven false alarms). The results showed that the last half an hour before the patient's death is very informative for diagnosing the patient's condition and to save his/her life. These results confirm that it is possible to predict mortality based on the features introduced in this paper, relying on the variations of the HRV dynamic characteristics.

  16. Recollection is a continuous process: Evidence from plurality memory receiver operating characteristics.

    PubMed

    Slotnick, Scott D; Jeye, Brittany M; Dodson, Chad S

    2016-01-01

    Is recollection a continuous/graded process or a threshold/all-or-none process? Receiver operating characteristic (ROC) analysis can answer this question as the continuous model and the threshold model predict curved and linear recollection ROCs, respectively. As memory for plurality, an item's previous singular or plural form, is assumed to rely on recollection, the nature of recollection can be investigated by evaluating plurality memory ROCs. The present study consisted of four experiments. During encoding, words (singular or plural) or objects (single/singular or duplicate/plural) were presented. During retrieval, old items with the same plurality or different plurality were presented. For each item, participants made a confidence rating ranging from "very sure old", which was correct for same plurality items, to "very sure new", which was correct for different plurality items. Each plurality memory ROC was the proportion of same versus different plurality items classified as "old" (i.e., hits versus false alarms). Chi-squared analysis revealed that all of the plurality memory ROCs were adequately fit by the continuous unequal variance model, whereas none of the ROCs were adequately fit by the two-high threshold model. These plurality memory ROC results indicate recollection is a continuous process, which complements previous source memory and associative memory ROC findings.

  17. Radiometry Measurements of Mars at 1064 nm Using the Mars Orbiter Laser Altimeter

    NASA Technical Reports Server (NTRS)

    Sun, Xiao-Li; Abshire, James B.; Neumann, Gregory A.; Zuber, Maria T.; Smith, David E. (Technical Monitor)

    2001-01-01

    Measurements by the Mars Orbiter Laser Altimeter (MOLA) on board the Mars Global Surveyor (MGS) may be used to provides a radiometric measurement of Mars in addition to the topographic measurement. We will describe the principle of operation, a mathematical model, and the receiver calibration in this presentation. MOLA was designed primarily to measure Mars topography, surface roughness end the bidirectional reflectance to the laser beam. To achieve the highest sensitivity the receiver detection threshold is dynamically adjusted to be as low as possible while keeping a predetermined false alarm rate. The average false alarm rate 29 monitored in real time on board MOLA via a noise counter, whose output is fed to the threshold control loop. The false alarm rate at a given threshold is a function of the detector output noise which is the sum of the photo detector, shot noise due to the background light seen by the detector and the dark noise. A mathematical model has been developed that can be used to numerically solve for the optical background power given the MOLA threshold setting and the average noise count. The radiance of Mars can then be determined by dividing the optical power by the solid angle subtended by the MOLA receiver, the receiver optical band-width, end the Mars surface area within the receiver field of view. The phase angle which is the sun-Mars-MOLA angle is available from the MGS database. MOLA also measures simultaneously the bidirectional reflectance of Mars vie its 106-lum loser beam at nadir with nearly zero phase angle. The optical bandwidth of the MOLA receiver is 2um full width at half maximum (FWHM) and centered at 106-lum. The receiver field of view is 0.95mrad FWHM. The nominated spacecraft altitude is 100km and the ground track speed is about 3km/s. Under normal operation, the noise counter are read and the threshold levels are updated at 1Hz. The receiver sensitivity is limited by the detector dark noise to about 0.1nW, which corresponds to less than 2% the maximum radiance during daytime from the brightest area on Mars. The results from the mathematical model agree well with the prelaunch measurements at several calibrated optical power levels. The radiance of sunlit Mars estimated with this technique correlates well with the measurement from the MGS. Thermal Emission Spectrometer (TES) and the Hubble Space Telescope at similar wavelength.

  18. Using GIS to evaluate a fire safety program in North Carolina.

    PubMed

    Dudley, Thomas; Creppage, Kathleen; Shanahan, Meghan; Proescholdbell, Scott

    2013-10-01

    Evaluating program impact is a critical aspect of public health. Utilizing Geographic Information Systems (GIS) is a novel way to evaluate programs which try to reduce residential fire injuries and deaths. The purpose of this study is to demonstrate the application of GIS within the evaluation of a smoke alarm installation program in North Carolina. This approach incorporates national fire incident data which, when linked with program data, provides a clear depiction of the 10 years impact of the Get Alarmed, NC! program and estimates the number of potential lives saved. We overlapped Get Alarmed, NC! program installation data with national information on fires using GIS to identify homes that experienced a fire after an alarm was installed and calculated potential lives saved based on program documentation and average housing occupancy. We found that using GIS was an efficient and quick way to match addresses from two distinct sources. From this approach we estimated that between 221 and 384 residents were potentially saved due to alarms installed in their homes by Get Alarmed, NC!. Compared with other program evaluations that require intensive and costly participant telephone surveys and/or in-person interviews, the GIS approach is inexpensive, quick, and can easily analyze large disparate datasets. In addition, it can be used to help target the areas most at risk from the onset. These benefits suggest that by incorporating previously unutilized data, the GIS approach has the potential for broader applications within public health program evaluation.

  19. Proposal and Implementation of a Robust Sensing Method for DVB-T Signal

    NASA Astrophysics Data System (ADS)

    Song, Chunyi; Rahman, Mohammad Azizur; Harada, Hiroshi

    This paper proposes a sensing method for TV signals of DVB-T standard to realize effective TV White Space (TVWS) Communication. In the TVWS technology trial organized by the Infocomm Development Authority (iDA) of Singapore, with regard to the sensing level and sensing time, detecting DVB-T signal at the level of -120dBm over an 8MHz channel with a sensing time below 1 second is required. To fulfill such a strict sensing requirement, we propose a smart sensing method which combines feature detection and energy detection (CFED), and is also characterized by using dynamic threshold selection (DTS) based on a threshold table to improve sensing robustness to noise uncertainty. The DTS based CFED (DTS-CFED) is evaluated by computer simulations and is also implemented into a hardware sensing prototype. The results show that the DTS-CFED achieves a detection probability above 0.9 for a target false alarm probability of 0.1 for DVB-T signals at the level of -120dBm over an 8MHz channel with the sensing time equals to 0.1 second.

  20. Nurses' Perceptions and Practices Related to Alarm Management: A Quality Improvement Initiative.

    PubMed

    Cameron, Hannah L; Little, Barbara

    2018-05-01

    The purpose of this quality improvement project was to develop, implement, and assess the effects of an alarm management policy and educational program on nurses' perceptions and practices of alarm management in an acute care hospital. Nurses from an acute care hospital in the southeastern United States attended a mandatory alarm management education program. The hospital implemented the evidence-based alarm management education to achieve the NPSG.06.01.01: Alarm Management. Pre- and posttests were administered to evaluate the education and the changes in nurses' perceptions and practices of clinical alarms. A total of 417 nurses received the educational intervention. All participants completed the pretest, and 215 (51%) completed the voluntary posttest. Significant improvements were made in alarm perceptions and practices. Nurses suggested unit-specific alarm education, improved staffing, and updated equipment. Findings support the benefits of continued education in alarm management for nurses. Bedside nurses are a critical member of a multidisciplinary alarm management team because they are at the forefront of patient safety and most at risk for experiencing alarm fatigue. J Contin Educ Nurs. 2018;49(5):207-215. Copyright 2018, SLACK Incorporated.

  1. The effectiveness of nurse education and training for clinical alarm response and management: a systematic review.

    PubMed

    Yue, Liqing; Plummer, Virginia; Cross, Wendy

    2017-09-01

    To identify the effectiveness of education interventions provided for nurses for clinical alarm response and management. Some education has been undertaken to improve clinical alarm response, but the evidence for evaluating effectiveness for nurse education interventions is limited. Systematic review. A systematic review of experimental studies published in English from 2005-2015 was conducted in four computerised databases (MEDLINE, EMBASE, CINAHL and Scopus). After identification, screening and appraisal using Joanna Briggs Institute instruments, quality research papers were selected, data extraction and analysis followed. Five studies met the inclusion criteria for alarm response and no articles were concerned with clinical alarm education for management. All had different types and methods of interventions and statistical pooling was not possible. Response accuracy, response time and perceptions were consistent when different interventions were adopted. A positive effect was identified when learning about general alarms, single alarms, sequential alarms and medium-level alarms for learning as the primary task. Nurses who were musically trained had a faster and more accurate alarm response. Simulation interventions had a positive effect, but the effect of education provided in the care unit was greater. Overall, clinical alarm awareness was improved through education activities. Nurses are the main users of healthcare alarms and work in complex environments with high numbers of alarms, including nuisance alarms and other factors. Alarm-related adverse events are common. The findings of a small number of experimental studies with diverse evidence included consideration of various factors when formulating education strategies. The factors which influence effectiveness of nurse education are nurse demographics, nurse participants with musical training, workload and characteristics of alarms. Education interventions based in clinical practice settings increase education effectiveness, although simulation can be effective. No study shows any type of intervention results in sustained improvement. There are workload implications in education and the matching of load, number and type of alarms with nurse demographics which should be evaluated. There also needs to be a connection between education and the clinical setting to contribute to clinical alarm awareness for undergraduate nurses and practicing nurses. Education solely supported by employers is insufficient. Patient safety and long-term effects must be further explored. © 2016 John Wiley & Sons Ltd.

  2. Biofeedback With Implanted Blood-Pressure Device

    NASA Technical Reports Server (NTRS)

    Rischell, Robert E.

    1988-01-01

    Additional uses found for equipment described in "Implanted Blood-Pressure-Measuring Device" (GSC-13042). Implanted with device electronic circuitry that measures, interprets, and transmits data via inductive link through patient's skin to external receiver. Receiver includes audible alarm generator activated when patient's blood pressure exceeds predetermined threshold. Also included in receiver a blood-pressure display, recorder, or both, for use by patient or physician.

  3. Emergency Vehicle Alarm System for Deaf Drivers by Using LEDs and Vibration Devices

    NASA Astrophysics Data System (ADS)

    Kuwahara, Noriaki; Morimoto, Kazunari; Kozuki, Kazumasa; Kawamura, Tomonori

    We are developing the emergency vehicle alarm system for deaf drivers by using LEDs and vibration devices. In order to design the alarm for deaf drivers, we have conducted basic experiment in order to evaluate perceptual characteristic on visibility of LED.

  4. Early detection of West Nile virus in France: quantitative assessment of syndromic surveillance system using nervous signs in horses.

    PubMed

    Faverjon, C; Vial, F; Andersson, M G; Lecollinet, S; Leblond, A

    2017-04-01

    West Nile virus (WNV) is a growing public health concern in Europe and there is a need to develop more efficient early detection systems. Nervous signs in horses are considered to be an early indicator of WNV and, using them in a syndromic surveillance system, might be relevant. In our study, we assessed whether or not data collected by the passive French surveillance system for the surveillance of equine diseases can be used routinely for the detection of WNV. We tested several pre-processing methods and detection algorithms based on regression. We evaluated system performances using simulated and authentic data and compared them to those of the surveillance system currently in place. Our results show that the current detection algorithm provided similar performances to those tested using simulated and real data. However, regression models can be easily and better adapted to surveillance objectives. The detection performances obtained were compatible with the early detection of WNV outbreaks in France (i.e. sensitivity 98%, specificity >94%, timeliness 2·5 weeks and around four false alarms per year) but further work is needed to determine the most suitable alarm threshold for WNV surveillance in France using cost-efficiency analysis.

  5. Auditory backup alarms: distance-at-first-detection via in-situ experimentation on alarm design and hearing protection effects.

    PubMed

    Alali, Khaled; Casali, John G

    2012-01-01

    The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them more time to react to approaching vehicles. The results of this study suggest that as the attenuation of the hearing protectors increases, precautions should be considered by safety professionals. This is because, as it was the case with the Bilsom passive earmuff and E-A-R/3M Combat ArmsTM earplug-passive steady state, high attenuation minimizes the detection distance and as a result on-foot workers will have less time to react to any approaching vehicle. The main effects of the type of backup alarm signal demonstrated a statistically-significant advantage of the standard backup alarm over the broadband backup alarm on detection distance in feet. The magnitude of the improvement produced by the standard backup alarm was 221.5 feet, a very large margin. For example, with a vehicle backing at 10 mph, the 221.5 ft decrease in detection distance with the Brigade alarm equates to the vehicle arriving 15 seconds sooner at the worker from the point at which its alarm was first heard.

  6. Substation alarm multiplexing system (SAMS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ElBadaly, H.; Gaughan, J.; Ward, G.

    1996-03-01

    This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less

  7. Ionization-chamber smoke detector system

    DOEpatents

    Roe, Robert F.

    1976-10-19

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system is designed to reduce false alarms caused by fluctuations in ambient temperature. Means are provided for periodically firing the gas discharge triode and each time recording the triggering voltage required. A computer compares each triggering voltage with its predecessor. The computer is programmed to energize an alarm if the difference between the two compared voltages is a relatively large value indicative of particulates in the measuring chamber and to disregard smaller differences typically resulting from changes in ambient temperature.

  8. Local ICA for the Most Wanted face recognition

    NASA Astrophysics Data System (ADS)

    Guan, Xin; Szu, Harold H.; Markowitz, Zvi

    2000-04-01

    Facial disguises of FBI Most Wanted criminals are inevitable and anticipated in our design of automatic/aided target recognition (ATR) imaging systems. For example, man's facial hairs may hide his mouth and chin but not necessarily the nose and eyes. Sunglasses will cover the eyes but not the nose, mouth, and chins. This fact motivates us to build sets of the independent component analyses bases separately for each facial region of the entire alleged criminal group. Then, given an alleged criminal face, collective votes are obtained from all facial regions in terms of 'yes, no, abstain' and are tallied for a potential alarm. Moreover, and innocent outside shall fall below the alarm threshold and is allowed to pass the checkpoint. Such a PD versus FAR called ROC curve is obtained.

  9. Measures of Groundwater Drought from the Long-term Monitoring Data in Korea

    NASA Astrophysics Data System (ADS)

    Chung, E.; Park, J.; Woo, N. C.

    2017-12-01

    Recently, drought has been increased in its severity and frequency along the climate change in Korea. There are several criteria for alarming drought, for instance, based on the no-rainfall days, the amount of stream discharge, and the water levels of reservoirs. However, farmers depending on groundwater still have been suffered in preparing drought especially in the Spring. No-rainfall days continue, groundwater exploitation increases, water table declines, stream discharge decreases, and then the effects of drought become serious. Thus, the drought index based on the groundwater level is needed for the preparedness of drought disaster. Palmer et al.(1965, USGS) has proposed a method to set the threshold for the decline of the groundwater level in 5 stages based on the daily water-level data over the last 30 years. In this study, according to Peters et al.(2003), the threshold of groundwater level was estimated using the daily water-level data at five sites with significant drought experiences in Korea. Water levels and precipitations data were obtained from the national groundwater monitoring wells and the automatic weather stations, respectively, for 10 years from 2005 to 2014. From the water-level changes, the threshold was calculated when the value of the drought criterion (c), the ratio of the deficit below the threshold to the deficit below the average, is 0.3. As a result, the monthly drought days were high in 2009 and 2011 in Uiryeong, and from 2005 to 2008 in Boeun. The validity of the approach and the threshold can be evaluated by comparing calculated monthly drought days with recorded drought in the past. Through groundwater drought research, it is expected that not only surface water also groundwater resource management should be implemented more efficiently to overcome drought disaster.

  10. The Fine Tuning of Pain Thresholds: A Sophisticated Double Alarm System

    PubMed Central

    Plaghki, Léon; Decruynaere, Céline; Van Dooren, Paul; Le Bars, Daniel

    2010-01-01

    Two distinctive features characterize the way in which sensations including pain, are evoked by heat: (1) a thermal stimulus is always progressive; (2) a painful stimulus activates two different types of nociceptors, connected to peripheral afferent fibers with medium and slow conduction velocities, namely Aδ- and C-fibers. In the light of a recent study in the rat, our objective was to develop an experimental paradigm in humans, based on the joint analysis of the stimulus and the response of the subject, to measure the thermal thresholds and latencies of pain elicited by Aδ- and C-fibers. For comparison, the same approach was applied to the sensation of warmth elicited by thermoreceptors. A CO2 laser beam raised the temperature of the skin filmed by an infrared camera. The subject stopped the beam when he/she perceived pain. The thermal images were analyzed to provide four variables: true thresholds and latencies of pain triggered by heat via Aδ- and C-fibers. The psychophysical threshold of pain triggered by Aδ-fibers was always higher (2.5–3°C) than that triggered by C-fibers. The initial skin temperature did not influence these thresholds. The mean conduction velocities of the corresponding fibers were 13 and 0.8 m/s, respectively. The triggering of pain either by C- or by Aδ-fibers was piloted by several factors including the low/high rate of stimulation, the low/high base temperature of the skin, the short/long peripheral nerve path and some pharmacological manipulations (e.g. Capsaicin). Warming a large skin area increased the pain thresholds. Considering the warmth detection gave a different picture: the threshold was strongly influenced by the initial skin temperature and the subjects detected an average variation of 2.7°C, whatever the initial temperature. This is the first time that thresholds and latencies for pain elicited by both Aδ- and C-fibers from a given body region have been measured in the same experimental run. Such an approach illustrates the role of nociception as a “double level” and “double release” alarm system based on level detectors. By contrast, warmth detection was found to be based on difference detectors. It is hypothesized that pain results from a CNS build-up process resulting from population coding and strongly influenced by the background temperatures surrounding at large the stimulation site. We propose an alternative solution to the conventional methods that only measure a single “threshold of pain”, without knowing which of the two systems is involved. PMID:20428245

  11. Development and experimental evaluation of an alarm concept for an integrated surgical workstation.

    PubMed

    Zeißig, Eva-Maria; Janß, Armin; Dell'Anna-Pudlik, Jasmin; Ziefle, Martina; Radermacher, Klaus

    2016-04-01

    Alarm conditions of the technical equipment in operating rooms represent a prevalent cause for interruptions of surgeons and scrub nurses, resulting in an increase of workload and potential reduction of patient safety. In this work, an alarm concept for an integrated operating room system based on open communication standards is developed and tested. In a laboratory experiment, the reactions of surgeons were analysed, comparing the displaying of alarms on an integrated workstation and on single devices: disruptive effects of alarm handling on primary task (ratings of perceived distraction, resumption lag, deterioration of speed, accuracy, and prospective memory), efficiency and effectiveness of identification of alarms, as well as perceived workload were included. The identification of the alarm cause is significantly more efficient and effective with the integrated alarm concept. Moreover, a slightly lower deterioration of performance of the primary task due to the interruption of alarm handling was observed. Displaying alarms on an integrated workstation supports alarm handling and consequently reduces disruptive effects on the primary task. The findings show that even small changes can reduce workload in a complex work environment like the operating room, resulting in improved patient safety.

  12. Mass detection with digitized screening mammograms by using Gabor features

    NASA Astrophysics Data System (ADS)

    Zheng, Yufeng; Agyepong, Kwabena

    2007-03-01

    Breast cancer is the leading cancer among American women. The current lifetime risk of developing breast cancer is 13.4% (one in seven). Mammography is the most effective technology presently available for breast cancer screening. With digital mammograms computer-aided detection (CAD) has proven to be a useful tool for radiologists. In this paper, we focus on mass detection that is a common category of breast cancers relative to calcification and architecture distortion. We propose a new mass detection algorithm utilizing Gabor filters, termed as "Gabor Mass Detection" (GMD). There are three steps in the GMD algorithm, (1) preprocessing, (2) generating alarms and (3) classification (reducing false alarms). Down-sampling, quantization, denoising and enhancement are done in the preprocessing step. Then a total of 30 Gabor filtered images (along 6 bands by 5 orientations) are produced. Alarm segments are generated by thresholding four Gabor images of full orientations (Stage-I classification) with image-dependent thresholds computed via histogram analysis. Next a set of edge histogram descriptors (EHD) are extracted from 24 Gabor images (6 by 4) that will be used for Stage-II classification. After clustering EHD features with fuzzy C-means clustering method, a k-nearest neighbor classifier is used to reduce the number of false alarms. We initially analyzed 431 digitized mammograms (159 normal images vs. 272 cancerous images, from the DDSM project, University of South Florida) with the proposed GMD algorithm. And a ten-fold cross validation was used for testing the GMD algorithm upon the available data. The GMD performance is as follows: sensitivity (true positive rate) = 0.88 at false positives per image (FPI) = 1.25, and the area under the ROC curve = 0.83. The overall performance of the GMD algorithm is satisfactory and the accuracy of locating masses (highlighting the boundaries of suspicious areas) is relatively high. Furthermore, the GMD algorithm can successfully detect early-stage (with small values of Assessment & low Subtlety) malignant masses. In addition, Gabor filtered images are used in both stages of classifications, which greatly simplifies the GMD algorithm.

  13. Optimization of a matched-filter receiver for frequency hopping code acquisition in jamming

    NASA Astrophysics Data System (ADS)

    Pawlowski, P. R.; Polydoros, A.

    A matched-filter receiver for frequency hopping (FH) code acquisition is optimized when either partial-band tone jamming or partial-band Gaussian noise jamming is present. The receiver is matched to a segment of the FH code sequence, sums hard per-channel decisions to form a test, and uses multiple tests to verify acquisition. The length of the matched filter and the number of verification tests are fixed. Optimization is then choosing thresholds to maximize performance based upon the receiver's degree of knowledge about the jammer ('side-information'). Four levels of side-information are considered, ranging from none to complete. The latter level results in a constant-false-alarm-rate (CFAR) design. At each level, performance sensitivity to threshold choice is analyzed. Robust thresholds are chosen to maximize performance as the jammer varies its power distribution, resulting in simple design rules which aid threshold selection. Performance results, which show that optimum distributions for the jammer power over the total FH bandwidth exist, are presented.

  14. Definition of Pluviometric Thresholds For A Real Time Flood Forecasting System In The Arno Watershed

    NASA Astrophysics Data System (ADS)

    Amadio, P.; Mancini, M.; Mazzetti, P.; Menduni, G.; Nativi, S.; Rabuffetti, D.; Ravazzani, G.; Rosso, R.

    The pluviometric flood forecasting thresholds are an easy method that helps river flood emergency management collecting data from limited area meteorologic model or telemetric raingauges. The thresholds represent the cumulated rainfall depth which generate critic discharge for a particular section. The thresholds were calculated for different sections of Arno river and for different antecedent moisture condition using the flood event distributed hydrologic model FEST. The model inputs were syntethic hietographs with different shape and duration. The system realibility has been verified by generating 500 year syntethic rainfall for 3 important subwatersheds of the studied area. A new technique to consider spatial variability of rainfall and soil properties effects on hydrograph has been investigated. The "Geomorphologic Weights" were so calculated. The alarm system has been implemented in a dedicated software (MIMI) that gets measured and forecast rainfall data from Autorità di Bacino and defines the state of the alert of the river sections.

  15. Evaluation of Standard Gear Metrics in Helicopter Flight Operation

    NASA Technical Reports Server (NTRS)

    Mosher, M.; Pryor, A. H.; Huff, E. M.

    2002-01-01

    Each false alarm made by a machine monitoring system carries a high price tag. The machine must be taken out of service, thoroughly inspected with possible disassembly, and then made ready for service. Loss of use of the machine and the efforts to inspect it are costly. In addition, if a monitoring system is prone to false alarms, the system will soon be turned off or ignored. For aircraft applications, one growing concern is that the dynamic flight environment differs from the laboratory environment where fault detection methods are developed and tested. Vibration measurements made in flight are less stationary than those made in a laboratory, or test facility, and thus a given fault detection method may produce more false alarms in flight than might be anticipated. In 1977. Stewart introduced several metrics, including FM0 and FM4, for evaluating the health of a gear. These metrics are single valued functions of the vibration signal that indicate if the signal deviates from an ideal model of the signal. FM0 is a measure of the ratio of the peak-to-peak level to the harmonic energy in the signal. FM4 is the kurtosis of the signal with the gear mesh harmonics and first order side bands removed. The underlying theory is that a vibration signal from a gear in good condition is expected to be dominated by a periodic signal at the gear mesh frequency. If one or a small number of gear teeth contain damage or faults, the signal will change, possibly showing increased amplitude, local phase changes or both near the damaged region of the gear. FM0 increases if a signal contains a local increase in amplitude. FM4 increases if a signal contains a local increase in amplitude or local phase change in a periodic signal. Over the years, other single value metrics were also introduced to detect the onset and growth of damage in gears. These various metrics have detected faults in several gear tests in experimental test rigs. Conditions in these tests have been steady state in the sense that the rpm, torque and forces on the gear have been held steady. For gears used in a dynamic environment such as that occurring in aircraft, the rpm, torque and forces on the gear are constantly changing. The authors have measured significant variation in rpm and torque in the transmissions of helicopters in controlled steady flight conditions flown by highly proficient test pilots. Statistical analyses of the data taken in flight show significant nonstationarity in the vibration measurements. These deviations from stationarity may increase false alarms in gear monitoring during aircraft flight. In the proposed paper, the authors will study vibration measurements made in flight on an AH- 1 Cobra and an OH-58C Kiowa helicopters. The primary focus will be the development of a methodology to assess the impact of nonstationarity on false alarms. Issues to be addressed include how time synchronous averages are constructed from raw data as well as how lack of stationarity effects the behavior of single value metrics. Emphasis will be placed on the occurrence of false alarms with the use of standard metrics. In order to maintain an acceptable level of false alarms in the flight environment, this study will also address the determination of appropriate threshold levels, which may need to be higher than for test rigs.

  16. Locomotor effects of a low-frequency fire alarm on C57BL/6 male mice: a preliminary study.

    PubMed

    Povroznik, Jessica M; Faith, Robert E; Kessler, Matthew J; Ali, Frank N; Kosik, James; Prince, Stephen; Engler-Chiurazzi, Elizabeth B

    2017-12-01

    Maintaining appropriate acoustic conditions for animal welfare and data collection are crucial in biomedical research facilities. Negative impacts of disruptive sound are known and can include auditory damage, immune function changes, and behavioral alterations. One type of disruptive sound occurring in research facilities is that of fire alarms. To ameliorate this problem, many facilities have incorporated the use of low-frequency fire alarms that emit tones outside the rodent audible range. The impact of these devices has been assumed to be negligible. However, this has yet to be evaluated with controlled behavioral experiments. Thus, our objective was to investigate the impact of low-frequency fire alarm exposure on locomotor behavior in the open field, a test sensitive to acoustic stimuli disruption. Male mice were randomized to three alarm exposure groups (No-Alarm; Alarm-During; and Alarm-After) and placed in individual photobeam-activated locomotor chambers. The Alarm-During group displayed significantly reduced horizontal locomotion, with a trend towards reduced vertical locomotion. These data suggest that a low-frequency brief alarm tone can temporarily disrupt movement, a valuable insight should an alarm be deployed. Further, findings support close collaboration between researchers and institutional facility staff to ensure appropriate acoustic conditions are maintained, whenever possible, for research animals.

  17. A Multi-Channel Method for Detecting Periodic Forced Oscillations in Power Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Follum, James D.; Tuffner, Francis K.

    2016-11-14

    Forced oscillations in electric power systems are often symptomatic of equipment malfunction or improper operation. Detecting and addressing the cause of the oscillations can improve overall system operation. In this paper, a multi-channel method of detecting forced oscillations and estimating their frequencies is proposed. The method operates by comparing the sum of scaled periodograms from various channels to a threshold. A method of setting the threshold to specify the detector's probability of false alarm while accounting for the correlation between channels is also presented. Results from simulated and measured power system data indicate that the method outperforms its single-channel counterpartmore » and is suitable for real-world applications.« less

  18. Detection of Nuclear Weapons and Materials: Science, Technologies, Observations

    DTIC Science & Technology

    2009-08-04

    use of photons, packets of energy with no rest mass and no electrical charge. Electromagnetic radiation consists of photons, and may be measured as...density is a bulk property, expressed as mass per unit volume. In general, the densest materials are those of high Z. These properties may be used...generally dictate detection threshold settings through their impact on innocent alarm rates. Characterization of these factors is critical to

  19. Monthly and seasonally verification of precipitation in Poland

    NASA Astrophysics Data System (ADS)

    Starosta, K.; Linkowska, J.

    2009-04-01

    The national meteorological service of Poland - the Institute of Meteorology and Water Management (IMWM) joined COSMO - The Consortium for Small Scale Modelling on July 2004. In Poland, the COSMO _PL model version 3.5 had run till June 2007. Since July 2007, the model version 4.0 has been running. The model runs in an operational mode at 14-km grid spacing, twice a day (00 UTC, 12 UTC). For scientific research also model with 7-km grid spacing is ran. Monthly and seasonally verification for the 24-hours (06 UTC - 06 UTC) accumulated precipitation is presented in this paper. The precipitation field of COSMO_LM had been verified against rain gauges network (308 points). The verification had been made for every month and all seasons from December 2007 to December 2008. The verification was made for three forecast days for selected thresholds: 0.5, 1, 2.5, 5, 10, 20, 25, 30 mm. Following indices from contingency table were calculated: FBI (bias), POD (probability of detection), PON (probability of detection of non event), FAR (False alarm rate), TSS (True sill statistic), HSS (Heidke skill score), ETS (Equitable skill score). Also percentile ranks and ROC-relative operating characteristic are presented. The ROC is a graph of the hit rate (Y-axis) against false alarm rate (X-axis) for different decision thresholds

  20. Monthly and seasonally verification of precipitation in Poland

    NASA Astrophysics Data System (ADS)

    Starosta, K.; Linkowska, J.

    2009-04-01

    The national meteorological service of Poland - the Institute of Meteorology and Water Management (IMWM) joined COSMO - The Consortium for Small Scale Modelling on July 2004. In Poland, the COSMO _PL model version 3.5 had run till June 2007. Since July 2007, the model version 4.0 has been running. The model runs in an operational mode at 14-km grid spacing, twice a day (00 UTC, 12 UTC). For scientific research also model with 7-km grid spacing is ran. Monthly and seasonally verification for the 24-hours (06 UTC - 06 UTC) accumulated precipitation is presented in this paper. The precipitation field of COSMO_LM had been verified against rain gauges network (308 points). The verification had been made for every month and all seasons from December 2007 to December 2008. The verification was made for three forecast days for selected thresholds: 0.5, 1, 2.5, 5, 10, 20, 25, 30 mm. Following indices from contingency table were calculated: FBI (bias), POD (probability of detection), PON (probability of detection of non event), FAR (False alarm rate), TSS (True sill statistic), HSS (Heidke skill score), ETS (Equitable skill score). Also percentile ranks and ROC-relative operating characteristic are presented. The ROC is a graph of the hit rate (Y-axis) against false alarm rate (X-axis) for different decision thresholds.

  1. Automatic fall detection using wearable biomedical signal measurement terminal.

    PubMed

    Nguyen, Thuy-Trang; Cho, Myeong-Chan; Lee, Tae-Soo

    2009-01-01

    In our study, we developed a mobile waist-mounted device which can monitor the subject's acceleration signal and detect the fall events in real-time with high accuracy and automatically send an emergency message to a remote server via CDMA module. When fall event happens, the system also generates an alarm sound at 50Hz to alarm other people until a subject can sit up or stand up. A Kionix KXM52-1050 tri-axial accelerometer and a Bellwave BSM856 CDMA standalone modem were used to detect and manage fall events. We used not only a simple threshold algorithm but also some supporting methods to increase an accuracy of our system (nearly 100% in laboratory environment). Timely fall detection can prevent regrettable death due to long-lie effect; therefore increase the independence of elderly people in an unsupervised living environment.

  2. Can triggered electromyography monitoring throughout retraction predict postoperative symptomatic neuropraxia after XLIF? Results from a prospective multicenter trial.

    PubMed

    Uribe, Juan S; Isaacs, Robert E; Youssef, Jim A; Khajavi, Kaveh; Balzer, Jeffrey R; Kanter, Adam S; Küelling, Fabrice A; Peterson, Mark D

    2015-04-01

    This multicenter study aims to evaluate the utility of triggered electromyography (t-EMG) recorded throughout psoas retraction during lateral transpsoas interbody fusion to predict postoperative changes in motor function. Three hundred and twenty-three patients undergoing L4-5 minimally invasive lateral interbody fusion from 21 sites were enrolled. Intraoperative data collection included initial t-EMG thresholds in response to posterior retractor blade stimulation and subsequent t-EMG threshold values collected every 5 min throughout retraction. Additional data collection included dimensions/duration of retraction as well as pre-and postoperative lower extremity neurologic exams. Prior to expanding the retractor, the lowestt-EMG threshold was identified posterior to the retractor in 94 % of cases. Postoperatively, 13 (4.5 %) patients had a new motor weakness that was consistent with symptomatic neuropraxia (SN) of lumbar plexus nerves on the approach side. There were no significant differences between patients with or without a corresponding postoperative SN with respect to initial posterior blade reading (p = 0.600), or retraction dimensions (p > 0.05). Retraction time was significantly longer in those patients with SN vs. those without (p = 0.031). Stepwise logistic regression showed a significant positive relationship between the presence of new postoperative SN and total retraction time (p < 0.001), as well as change in t-EMG thresholds over time (p < 0.001), although false positive rates (increased threshold in patients with no new SN) remained high regardless of the absolute increase in threshold used to define an alarm criteria. Prolonged retraction time and coincident increases in t-EMG thresholds are predictors of declining nerve integrity. Increasing t-EMG thresholds, while predictive of injury, were also observed in a large number of patients without iatrogenic injury, with a greater predictive value in cases with extended duration. In addition to a careful approach with minimal muscle retraction and consistent lumbar plexus directional retraction, the incidence of postoperative motor neuropraxia may be reduced by limiting retraction time and utilizing t-EMG throughout retraction, while understanding that the specificity of this monitoring technique is low during initial retraction and increases with longer retraction duration.

  3. A Total Validation Approach for assessing the RST technique in forest fire detection and monitoring

    NASA Astrophysics Data System (ADS)

    Mazzeo, Giuseppe; Baldassarre, Giuseppe; Corrado, Rosita; Filizzola, Carolina; Genzano, Nicola; Marchese, Francesco; Paciello, Rossana; Pergola, Nicola; Tramutoli, Valerio

    2010-05-01

    Several studies have shown that high temporal resolution sensors such as AVHRR (Advanced Very High Resolution Radiometer) aboard NOAA (National Oceanic and Atmospheric Administration) satellites, MODIS (Moderate Resolution Imaging Spectroradiometer) aboard EOS (Earth Observing System) satellites and, more recently, SEVIRI (Spinning Enhanced Visible and Infrared Imager) aboard MSG (Meteosat Second Generation) platforms, are suitable for detecting and monitoring forest fires. At the same time, many satellite-based techniques have been proposed for fire detection, but most of them, based on single image fixed-thresholds, often generate false alarms mainly due to the contribution of the reflected solar radiation in daytime, atmospheric effects, etc., so that they result to have scarce reliability when applied in an operational scenario. Other algorithms, which are quite reliable thanks to their multitemporal and/or contextual nature, may turn out to be hardly applicable so that they cannot be inserted in whatever operative schemes. An innovative approach, named RST - Robust Satellite Technique, already applied for the monitoring of major natural and environmental risks has been recently used for fire detection and monitoring. The RST approach is based on local (in space and time) thresholds which are automatically computed on the basis of long temporal series of satellite data. It demonstrated already good performances in many cases of applications, but recently for the first time a total validation approach (TVA) was experimented in collaboration with administrators, decision makers and local agencies, in order to evaluate the actual reliability and sensitivity of RST in a pre-operational context. TVA, based on a systematic study of the origin of each hot spot identified by RST, allowed us to recognize most of them as actual thermal anomalies (associated to small fires, to variations of thermal emission in industrial plants, etc.) and not as false alarms simply because not associated to officially documented forest fires. Some results of recent campaigns both of winter and summer fire detection and monitoring in Italy will be shown and discussed.

  4. Threshold-based system for noise detection in multilead ECG recordings.

    PubMed

    Jekova, Irena; Krasteva, Vessela; Christov, Ivaylo; Abächerli, Roger

    2012-09-01

    This paper presents a system for detection of the most common noise types seen on the electrocardiogram (ECG) in order to evaluate whether an episode from 12-lead ECG is reliable for diagnosis. It implements criteria for estimation of the noise corruption level in specific frequency bands, aiming to identify the main sources of ECG quality disruption, such as missing signal or limited dynamics of the QRS components above 4 Hz; presence of high amplitude and steep artifacts seen above 1 Hz; baseline drift estimated at frequencies below 1 Hz; power-line interference in a band ±2 Hz around its central frequency; high-frequency and electromyographic noises above 20 Hz. All noise tests are designed to process the ECG series in the time domain, including 13 adjustable thresholds for amplitude and slope criteria which are evaluated in adjustable time intervals, as well as number of leads. The system allows flexible extension toward application-specific requirements for the noise levels in acceptable quality ECGs. Training of different thresholds' settings to determine different positive noise detection rates is performed with the annotated set of 1000 ECGs from the PhysioNet database created for the Computing in Cardiology Challenge 2011. Two implementations are highlighted on the receiver operating characteristic (area 0.968) to fit to different applications. The implementation with high sensitivity (Se = 98.7%, Sp = 80.9%) appears as a reliable alarm when there are any incidental problems with the ECG acquisition, while the implementation with high specificity (Sp = 97.8%, Se = 81.8%) is less susceptible to transient problems but rather validates noisy ECGs with acceptable quality during a small portion of the recording.

  5. Caution and Warning Alarm Design and Evaluation for NASA CEV Auditory Displays: SHFE Information Presentation Directed Research Project (DRPP) report 12.07

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Godfroy, Martine; Sandor, Aniko; Holden, Kritina

    2008-01-01

    The design of caution-warning signals for NASA s Crew Exploration Vehicle (CEV) and other future spacecraft will be based on both best practices based on current research and evaluation of current alarms. A design approach is presented based upon cross-disciplinary examination of psychoacoustic research, human factors experience, aerospace practices, and acoustical engineering requirements. A listening test with thirteen participants was performed involving ranking and grading of current and newly developed caution-warning stimuli under three conditions: (1) alarm levels adjusted for compliance with ISO 7731, "Danger signals for work places - Auditory Danger Signals", (2) alarm levels adjusted to an overall 15 dBA s/n ratio and (3) simulated codec low-pass filtering. Questionnaire data yielded useful insights regarding cognitive associations with the sounds.

  6. Effects of a fire alarm strobe light on fecal corticosterone metabolite concentrations in mice.

    PubMed

    Godfrey, Denice; Silverman, Jerald

    2009-02-01

    The type and location of fire alarms are important considerations in animal facility design. The Guide for the Care and Use of Laboratory Animals recommends minimizing animal exposure to such alarms. Nevertheless, it is often necessary to maintain fire alarms within animal housing or procedural areas. The authors exposed male mice to the flashing strobe light component of a standard fire alarm and evaluated mouse fecal corticosterone concentration, which is known to be an indicator of stress. Mice were exposed to the strobe light for 5 min during either the light or the dark phase of the light:dark cycle. The authors collected fecal samples every 6 h for 24 h before exposing mice to the alarm and every 6 h for 24 h after exposure. Fecal samples taken before exposure (baseline samples) showed a normal circadian pattern of corticosterone metabolite excretion. In fecal samples taken after mice were exposed to the fire alarm, metabolite concentrations did not significantly differ from baseline concentrations over time.

  7. A Residual Chlorine Removal Method to Allow Drinking Water Monitoring by Biological Early Warning Systems

    DTIC Science & Technology

    2005-03-18

    Lepomis macrochirus). have been disinfected with chloramines The threshold for a toxicity alarm by was not determined. Biomonitor users the USACEHR...residual solution. This caused an elevated chlorine from water disinfected with chlorine level (measured at 0.08 FRC) chloramines . In testing with a rapid...have been disinfected A Handbook, Volume 2, 8. Kluwer with chloramines . Academic/Plenum Publishers, New York, NY, pp 123-141. 5. Recommendations

  8. Work zone intrusion alarm effectiveness.

    DOT National Transportation Integrated Search

    2010-09-01

    16. Abstract : The New Jersey Department of Transportation (NJDOT) commissioned a study to evaluate how : effective a work zone safety device known as the SonoBlaster! Work Zone Intrusion Alarm would be : in protecting maintenance workers fro...

  9. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Moses, Haifa

    2016-01-01

    Speech alarms have been used extensively in aviation and included in International Building Codes (IBC) and National Fire Protection Association's (NFPA) Life Safety Code. However, they have not been implemented on space vehicles. Previous studies conducted at NASA JSC showed that speech alarms lead to faster identification and higher accuracy. This research evaluated updated speech and tone alerts in a laboratory environment and in the Human Exploration Research Analog (HERA) in a realistic setup.

  10. False alarm recognition in hyperspectral gas plume identification

    DOEpatents

    Conger, James L [San Ramon, CA; Lawson, Janice K [Tracy, CA; Aimonetti, William D [Livermore, CA

    2011-03-29

    According to one embodiment, a method for analyzing hyperspectral data includes collecting first hyperspectral data of a scene using a hyperspectral imager during a no-gas period and analyzing the first hyperspectral data using one or more gas plume detection logics. The gas plume detection logic is executed using a low detection threshold, and detects each occurrence of an observed hyperspectral signature. The method also includes generating a histogram for all occurrences of each observed hyperspectral signature which is detected using the gas plume detection logic, and determining a probability of false alarm (PFA) for all occurrences of each observed hyperspectral signature based on the histogram. Possibly at some other time, the method includes collecting second hyperspectral data, and analyzing the second hyperspectral data using the one or more gas plume detection logics and the PFA to determine if any gas is present. Other systems and methods are also included.

  11. Calibration and validation of rainfall thresholds for shallow landslide forecasting in Sicily, southern Italy

    NASA Astrophysics Data System (ADS)

    Gariano, S. L.; Brunetti, M. T.; Iovine, G.; Melillo, M.; Peruccacci, S.; Terranova, O.; Vennari, C.; Guzzetti, F.

    2015-01-01

    Empirical rainfall thresholds are tools to forecast the possible occurrence of rainfall-induced shallow landslides. Accurate prediction of landslide occurrence requires reliable thresholds, which need to be properly validated before their use in operational warning systems. We exploited a catalogue of 200 rainfall conditions that have resulted in at least 223 shallow landslides in Sicily, southern Italy, in the 11-year period 2002-2011, to determine regional event duration-cumulated event rainfall (ED) thresholds for shallow landslide occurrence. We computed ED thresholds for different exceedance probability levels and determined the uncertainty associated to the thresholds using a consolidated bootstrap nonparametric technique. We further determined subregional thresholds, and we studied the role of lithology and seasonal periods in the initiation of shallow landslides in Sicily. Next, we validated the regional rainfall thresholds using 29 rainfall conditions that have resulted in 42 shallow landslides in Sicily in 2012. We based the validation on contingency tables, skill scores, and a receiver operating characteristic (ROC) analysis for thresholds at different exceedance probability levels, from 1% to 50%. Validation of rainfall thresholds is hampered by lack of information on landslide occurrence. Therefore, we considered the effects of variations in the contingencies and the skill scores caused by lack of information. Based on the results obtained, we propose a general methodology for the objective identification of a threshold that provides an optimal balance between maximization of correct predictions and minimization of incorrect predictions, including missed and false alarms. We expect that the methodology will increase the reliability of rainfall thresholds, fostering the operational use of validated rainfall thresholds in operational early warning system for regional shallow landslide forecasting.

  12. Terahertz Technology and Molecular Interactions

    DTIC Science & Technology

    2010-12-16

    numerical identification algorithm, based on a simple threshold model, showed that the probability for false alarm ( PFA ) for the least favorable of...Briefly put, Phase I of MACS was to develop in 18 months a sensor system in a 1 cu ft vol- ume that could correctly identify with a PFA < 10-4 gases in a...observe spectral lines that have fractional ab- sorptions of 10-7 there are six orders of magnitude in sensitivity at stake. If spectral lines have

  13. Determination of Network Attributes from a High Resolution Terrain Data Base

    DTIC Science & Technology

    1987-09-01

    and existing models is in the method used to make decisions. All of ,he models- reviewed when developing the ALARM strategy depended either on threshold...problems with the methods currently accepted and used to *model the decision process. These methods are recognized because they have their uses...observation, detection, and lines of sight along a narrow strip of terrain relative to the overall size of the sectors of the two forces. Existing methods of

  14. Effect of electronic ANR and conventional hearing protectors on vehicle backup alarm detection in noise.

    PubMed

    Casali, John G; Robinson, Gary S; Dabney, Erika Christian; Gauger, Dan

    2004-01-01

    An experiment was conducted wherein masked thresholds (using ascending method of limits) for a backup alarm were obtained in pink and red noise at 85 and 100 dBA for 12 participants immersed in a probability monitoring task and wearing a conventional passive hearing protection device (HPD, an earmuff or a foam earplug), an active noise reduction (ANR) headset, or no HPD at all (only in 85 dBA noise). Results revealed statistically significant between-HPD differences in red noise (from 2.3 to 3.1 dB) and in the 100-dBA noise level (from 2.6 to 4.3 dB). An additional finding, which corroborates other studies using different protocols, was that masked thresholds in 85-dBA noise were significantly lower (from 3.2 to 4.4 dB) for the occluded conditions (wearing an HPD) than for the open-ear (unoccluded) condition. This result refutes the belief among many normal-hearing workers that the use of HPDs in relatively low levels of noise compromises their ability to hear necessary workplace sounds. Actual or potential applications of this research include (a) the selection of appropriate HPDs for low-frequency-biased noise exposures wherein signal detection is important and (b) gaining insight into the appropriateness of ANR-based HPDs for certain industrial noise environments.

  15. Comparison between intensity- duration thresholds and cumulative rainfall thresholds for the forecasting of landslide

    NASA Astrophysics Data System (ADS)

    Lagomarsino, Daniela; Rosi, Ascanio; Rossi, Guglielmo; Segoni, Samuele; Catani, Filippo

    2014-05-01

    This work makes a quantitative comparison between the results of landslide forecasting obtained using two different rainfall threshold models, one using intensity-duration thresholds and the other based on cumulative rainfall thresholds in an area of northern Tuscany of 116 km2. The first methodology identifies rainfall intensity-duration thresholds by means a software called MaCumBA (Massive CUMulative Brisk Analyzer) that analyzes rain-gauge records, extracts the intensities (I) and durations (D) of the rainstorms associated with the initiation of landslides, plots these values on a diagram, and identifies thresholds that define the lower bounds of the I-D values. A back analysis using data from past events can be used to identify the threshold conditions associated with the least amount of false alarms. The second method (SIGMA) is based on the hypothesis that anomalous or extreme values of rainfall are responsible for landslide triggering: the statistical distribution of the rainfall series is analyzed, and multiples of the standard deviation (σ) are used as thresholds to discriminate between ordinary and extraordinary rainfall events. The name of the model, SIGMA, reflects the central role of the standard deviations in the proposed methodology. The definition of intensity-duration rainfall thresholds requires the combined use of rainfall measurements and an inventory of dated landslides, whereas SIGMA model can be implemented using only rainfall data. These two methodologies were applied in an area of 116 km2 where a database of 1200 landslides was available for the period 2000-2012. The results obtained are compared and discussed. Although several examples of visual comparisons between different intensity-duration rainfall thresholds are reported in the international literature, a quantitative comparison between thresholds obtained in the same area using different techniques and approaches is a relatively undebated research topic.

  16. The "Let's Get Alarmed!" initiative: a smoke alarm giveaway programme.

    PubMed

    DiGuiseppi, C; Slater, S; Roberts, I; Adams, L; Sculpher, M; Wade, A; McCarthy, M

    1999-09-01

    To reduce fires and fire related injuries by increasing the prevalence of functioning smoke alarms in high risk households. The programme was delivered in an inner London area with above average material deprivation and below average smoke alarm ownership. The target population included low income and rental households and households with elderly persons or young children. Forty wards, averaging 4000 households each, were randomised to intervention or control status. Free smoke alarms and fire safety information were distributed in intervention wards by community groups and workers as part of routine activities and by paid workers who visited target neighbourhoods. Recipients provided data on household age distribution and housing tenure. Programme costs were documented from a societal perspective. Data are being collected on smoke alarm ownership and function, and on fires and related injuries and their costs. Community and paid workers distributed 20,050 smoke alarms, potentially sufficient to increase smoke alarm ownership by 50% in intervention wards. Compared with the total study population, recipients included greater proportions of low income and rental households and households including children under 5 years or adults aged 65 and older. Total programme costs were 145,087 Pounds. It is possible to implement a large scale smoke alarm giveaway programme targeted to high risk households in a densely populated, multicultural, materially deprived community. The programme's effects on the prevalence of installed and functioning alarms and the incidence of fires and fire related injuries, and its cost effectiveness, are being evaluated as a randomized controlled trial.

  17. Implementation and application of moving average as continuous analytical quality control instrument demonstrated for 24 routine chemistry assays.

    PubMed

    Rossum, Huub H van; Kemperman, Hans

    2017-07-26

    General application of a moving average (MA) as continuous analytical quality control (QC) for routine chemistry assays has failed due to lack of a simple method that allows optimization of MAs. A new method was applied to optimize the MA for routine chemistry and was evaluated in daily practice as continuous analytical QC instrument. MA procedures were optimized using an MA bias detection simulation procedure. Optimization was graphically supported by bias detection curves. Next, all optimal MA procedures that contributed to the quality assurance were run for 100 consecutive days and MA alarms generated during working hours were investigated. Optimized MA procedures were applied for 24 chemistry assays. During this evaluation, 303,871 MA values and 76 MA alarms were generated. Of all alarms, 54 (71%) were generated during office hours. Of these, 41 were further investigated and were caused by ion selective electrode (ISE) failure (1), calibration failure not detected by QC due to improper QC settings (1), possible bias (significant difference with the other analyzer) (10), non-human materials analyzed (2), extreme result(s) of a single patient (2), pre-analytical error (1), no cause identified (20), and no conclusion possible (4). MA was implemented in daily practice as a continuous QC instrument for 24 routine chemistry assays. In our setup when an MA alarm required follow-up, a manageable number of MA alarms was generated that resulted in valuable MA alarms. For the management of MA alarms, several applications/requirements in the MA management software will simplify the use of MA procedures.

  18. Risk and return: evaluating Reverse Tracing of Precursors earthquake predictions

    NASA Astrophysics Data System (ADS)

    Zechar, J. Douglas; Zhuang, Jiancang

    2010-09-01

    In 2003, the Reverse Tracing of Precursors (RTP) algorithm attracted the attention of seismologists and international news agencies when researchers claimed two successful predictions of large earthquakes. These researchers had begun applying RTP to seismicity in Japan, California, the eastern Mediterranean and Italy; they have since applied it to seismicity in the northern Pacific, Oregon and Nevada. RTP is a pattern recognition algorithm that uses earthquake catalogue data to declare alarms, and these alarms indicate that RTP expects a moderate to large earthquake in the following months. The spatial extent of alarms is highly variable and each alarm typically lasts 9 months, although the algorithm may extend alarms in time and space. We examined the record of alarms and outcomes since the prospective application of RTP began, and in this paper we report on the performance of RTP to date. To analyse these predictions, we used a recently developed approach based on a gambling score, and we used a simple reference model to estimate the prior probability of target earthquakes for each alarm. Formally, we believe that RTP investigators did not rigorously specify the first two `successful' predictions in advance of the relevant earthquakes; because this issue is contentious, we consider analyses with and without these alarms. When we included contentious alarms, RTP predictions demonstrate statistically significant skill. Under a stricter interpretation, the predictions are marginally unsuccessful.

  19. Noisy anthropogenic infrastructure interferes with alarm responses in Savannah sparrows (Passerculus sandwichensis)

    PubMed Central

    Koper, Nicola

    2018-01-01

    Many birds rely on anti-predator communication to protect their nests; however, anthropogenic noise from industrial activities such as oil and gas development may disrupt acoustic communication. Here, we conducted acoustic playback experiments to determine whether Savannah sparrows (Passerculus sandwichensis) responded to conspecific alarm calls by delaying feeding visits, and whether this response was impaired by noise-producing natural gas compressor stations, generator- or grid-powered screw pump oil wells, and noise amplitude. We played alarm calls, and, as a control, western meadowlark songs, to Savannah sparrows as they approached their nests to feed their nestlings, and measured feeding latency. The greatest impacts on behaviour were detected at the noisiest treatment, compressor stations; feeding latency was shortened here compared with control sites, which may expose nests to greater predation risk. As noise amplitudes increased, Savannah sparrows took longer to feed following meadowlark playbacks, perhaps because noise interfered with interpretation of acoustic cues. The effects of compressor stations on anti-predator behaviour may be best explained by the distracting effects of anthropogenic noise, while increases in feeding latency following meadowlark playbacks may be explained by a heightened response threshold caused by acoustic masking. Industrial infrastructure can influence the reproductive success of wildlife through its impact on perception and interpretation of conspecific signals, but these effects are complex. PMID:29892404

  20. Clinical evaluation of a noninvasive alarm system for nocturnal hypoglycemia.

    PubMed

    Skladnev, Victor N; Ghevondian, Nejhdeh; Tarnavskii, Stanislav; Paramalingam, Nirubasini; Jones, Timothy W

    2010-01-01

    The aim of this study was to evaluate the performance of a prototype noninvasive alarm system (HypoMon) for the detection of nocturnal hypoglycemia. A prospective cohort study evaluated an alarm system that included a sensor belt, a radio frequency transmitter for chest belt signals, and a receiver. The receiver incorporated integrated "real-time" algorithms designed to recognize hypoglycemia "signatures" in the physiological parameters monitored by the sensor belt. Fifty-two children and young adults with type 1 diabetes mellitus (T1DM) participated in this blinded, prospective, in-clinic, overnight study. Participants had a mean age of 16 years (standard deviation 2.1, range 12-20 years) and were asked to follow their normal meal and insulin routines for the day of the study. Participants had physiological parameters monitored overnight by a single HypoMon system. Their BG levels were also monitored overnight at regular intervals via an intravenous cannula and read on two independent Yellow Springs Instruments analyzers. Hypoglycemia was not induced by any manipulations of diabetes management, rather the subjects were monitored overnight for "natural" occurrences of hypoglycemia. Performance analyses included comparing HypoMon system alarm times with allowed time windows associated with each hypoglycemic event. The primary recognition algorithm in the prototype alarm system performed at a level consistent with expectations based on prior user surveys. The HypoMon system correctly recognized 8 out of the 11 naturally occurring overnight hypoglycemic events and falsely alarmed on 13 out of the remaining 41 normal nights [sensitivity 73% (8/11), specificity 68% (28/41), positive predictive value 38%,negative predictive value 90%]. The prototype HypoMon shows potential as an adjunct method for noninvasive overnight monitoring for hypoglycemia events in young people with T1DM. 2010 Diabetes Technology Society.

  1. Network Algorithms for Detection of Radiation Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, Nageswara S; Brooks, Richard R; Wu, Qishi

    In support of national defense, Domestic Nuclear Detection Office s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) amore » notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2 *2 NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.« less

  2. [A Smart Low-Power-Consumption ECG Monitor Based on MSP430F5529 and CC2540].

    PubMed

    Gong, Yuan; Cao, Jin; Luo, Zehui; Zhou, Guohui

    2015-07-01

    A design of ECG monitor was presented in this paper. It is based on the latest MCU and BLE4.0 technologies and can interact with multi-platform smart devices with extra low power consumption. Besides, a clinical expansion part can realize functions including displaying the real-time ECG and heart rate curve, reading abnormal ECG signals stored in the monitor, and setting alarm threshold. These functions are suitable for follow-up use.

  3. Radon Spectrum and Its Application for Small Moving Target Detection

    DTIC Science & Technology

    2015-04-01

    cumulative distribution function) starts separating from the exact distribution only at the very end of the upper tail, normally in the 610−= faP or...131059.1 −×= PNtotal (15) According to (15), for instance, to determine the threshold for 610−= faP , a total 91059.1 × samples shall...is the incomplete Gamma function9 Suppose we require a false-alarm rate of 610−= faP for the original data, therefore after non-coherent multi

  4. An experimental investigation of the effects of alarm processing and display on operator performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Hara, J.; Brown, W.; Hallbert, B.

    1998-03-01

    This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluatemore » the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance, operator task performance, situation awareness, and workload were obtained. In addition, operator opinions and evaluations of the alarm processing and display conditions were collected. No deficient performance was observed in any of the experimental conditions, providing confirmatory support for many design review guidelines. The operators identified numerous strengths and weaknesses associated with individual alarm design characteristics.« less

  5. Development of an Accident Reproduction Simulator System Using a Hemodialysis Extracorporeal Circulation System.

    PubMed

    Nishite, Yoshiaki; Takesawa, Shingo

    2016-01-01

    Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training.

  6. Review of syndromic surveillance: implications for waterborne disease detection

    PubMed Central

    Berger, Magdalena; Shiau, Rita; Weintraub, June M

    2006-01-01

    Syndromic surveillance is the gathering of data for public health purposes before laboratory or clinically confirmed information is available. Interest in syndromic surveillance has increased because of concerns about bioterrorism. In addition to bioterrorism detection, syndromic surveillance may be suited to detecting waterborne disease outbreaks. Theoretical benefits of syndromic surveillance include potential timeliness, increased response capacity, ability to establish baseline disease burdens, and ability to delineate the geographical reach of an outbreak. This review summarises the evidence gathered from retrospective, prospective, and simulation studies to assess the efficacy of syndromic surveillance for waterborne disease detection. There is little evidence that syndromic surveillance mitigates the effects of disease outbreaks through earlier detection and response. Syndromic surveillance should not be implemented at the expense of traditional disease surveillance, and should not be relied upon as a principal outbreak detection tool. The utility of syndromic surveillance is dependent on alarm thresholds that can be evaluated in practice. Syndromic data sources such as over the counter drug sales for detection of waterborne outbreaks should be further evaluated. PMID:16698988

  7. Threshold magnitudes for a multichannel correlation detector in background seismicity

    DOE PAGES

    Carmichael, Joshua D.; Hartse, Hans

    2016-04-01

    Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, Joshua D.; Hartse, Hans

    Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less

  9. Judging the urgency of non-verbal auditory alarms: a case study.

    PubMed

    Arrabito, G Robert; Mondor, Todd; Kent, Kimberley

    2004-06-22

    When designed correctly, non-verbal auditory alarms can convey different levels of urgency to the aircrew, and thereby permit the operator to establish the appropriate level of priority to address the alarmed condition. The conveyed level of urgency of five non-verbal auditory alarms presently used in the Canadian Forces CH-146 Griffon helicopter was investigated. Pilots of the CH-146 Griffon helicopter and non-pilots rated the perceived urgency of the signals using a rating scale. The pilots also ranked the urgency of the alarms in a post-experiment questionnaire to reflect their assessment of the actual situation that triggers the alarms. The results of this investigation revealed that participants' ratings of perceived urgency appear to be based on the acoustic properties of the alarms which are known to affect the listener's perceived level of urgency. Although for 28% of the pilots the mapping of perceived urgency to the urgency of their perception of the triggering situation was statistically significant for three of the five alarms, the overall data suggest that the triggering situations are not adequately conveyed by the acoustic parameters inherent in the alarms. The pilots' judgement of the triggering situation was intended as a means of evaluating the reliability of the alerting system. These data will subsequently be discussed with respect to proposed enhancements in alerting systems as it relates to addressing the problem of phase of flight. These results call for more serious consideration of incorporating situational awareness in the design and assignment of auditory alarms in aircraft.

  10. SCADA alarms processing for wind turbine component failure detection

    NASA Astrophysics Data System (ADS)

    Gonzalez, E.; Reder, M.; Melero, J. J.

    2016-09-01

    Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.

  11. Validation of the Rome III criteria and alarm symptoms for recurrent abdominal pain in children.

    PubMed

    Gijsbers, Carolien F M; Benninga, Marc A; Schweizer, Joachim J; Kneepkens, C M Frank; Vergouwe, Yvonne; Büller, Hans A

    2014-06-01

    Rome criteria were formulated to define functional gastrointestinal disorders (Rome III criteria, 2006) excluding organic diagnoses when alarm symptoms were absent. The aims of the study were to validate the Rome III criteria as to their capacity to differentiate between organic and functional abdominal pain and to assess the role of alarm symptoms in this differentiation. During 2 years all of the patients (ages 4-16 years) presenting with recurrent abdominal pain (Apley criteria) and referred to secondary care were included. Clinical diagnoses were based on protocolized evaluation and intervention with 6-month follow-up. Alarm symptoms were registered. Rome III criteria for functional pain syndromes were assigned independently. Descriptive statistical analyses were performed. In 200 patients (87 boys, mean age 8.8 years), organic (17%), functional (40%), combined organic and functional (9%), spontaneous recovery (27%), and other (8%) clinical diagnoses were established. Alarm symptoms were found in 57.5% (organic causes 56%, functional causes 61%). The evaluation for Rome symptom clusters revealed symptoms of irritable bowel syndrome in 27%, functional dyspepsia in 15%, functional abdominal pain in 28%, functional abdominal pain syndrome in 14.5%, and no pain syndrome in 15.5%. Rome diagnoses, based on symptoms and absence of alarm symptoms, predicted functional clinical diagnosis with sensitivity 0.35 (95% confidence interval 0.27-0.43), specificity 0.60 (0.46-0.73), positive predictive value 0.71 (0.61-0.82), and negative predictive value of 0.24 (0.17-0.32). The Rome III criteria for abdominal pain are not specific enough to rule out organic causes. Alarm symptoms do not differentiate between organic and functional abdominal pain.

  12. Faster clinical response to the onset of adverse events: A wearable metacognitive attention aid for nurse triage of clinical alarms.

    PubMed

    McFarlane, Daniel C; Doig, Alexa K; Agutter, James A; Brewer, Lara M; Syroid, Noah D; Mittu, Ranjeev

    2018-01-01

    This study evaluates the potential for improving patient safety by introducing a metacognitive attention aid that enables clinicians to more easily access and use existing alarm/alert information. It is hypothesized that this introduction will enable clinicians to easily triage alarm/alert events and quickly recognize emergent opportunities to adapt care delivery. The resulting faster response to clinically important alarms/alerts has the potential to prevent adverse events and reduce healthcare costs. A randomized within-subjects single-factor clinical experiment was conducted in a high-fidelity 20-bed simulated acute care hospital unit. Sixteen registered nurses, four at a time, cared for five simulated patients each. A two-part highly realistic clinical scenario was used that included representative: tasking; information; and alarms/alerts. The treatment condition introduced an integrated wearable attention aid that leveraged metacognition methods from proven military systems. The primary metric was time for nurses to respond to important alarms/alerts. Use of the wearable attention aid resulted in a median relative within-subject improvement for individual nurses of 118% (W = 183, p = 0.006). The top quarter of relative improvement was 3,303% faster (mean; 17.76 minutes reduced to 1.33). For all unit sessions, there was an overall 148% median faster response time to important alarms (8.12 minutes reduced to 3.27; U = 2.401, p = 0.016), with 153% median improvement in consistency across nurses (F = 11.670, p = 0.001). Existing device-centric alarm/alert notification solutions can require too much time and effort for nurses to access and understand. As a result, nurses may ignore alarms/alerts as they focus on other important work. There has been extensive research on reducing alarm frequency in healthcare. However, alarm safety remains a top problem. Empirical observations reported here highlight the potential of improving patient safety by supporting the meta-work of checking alarms.

  13. Faster clinical response to the onset of adverse events: A wearable metacognitive attention aid for nurse triage of clinical alarms

    PubMed Central

    Doig, Alexa K.; Agutter, James A.; Brewer, Lara M.; Syroid, Noah D.; Mittu, Ranjeev

    2018-01-01

    Objective This study evaluates the potential for improving patient safety by introducing a metacognitive attention aid that enables clinicians to more easily access and use existing alarm/alert information. It is hypothesized that this introduction will enable clinicians to easily triage alarm/alert events and quickly recognize emergent opportunities to adapt care delivery. The resulting faster response to clinically important alarms/alerts has the potential to prevent adverse events and reduce healthcare costs. Materials and methods A randomized within-subjects single-factor clinical experiment was conducted in a high-fidelity 20-bed simulated acute care hospital unit. Sixteen registered nurses, four at a time, cared for five simulated patients each. A two-part highly realistic clinical scenario was used that included representative: tasking; information; and alarms/alerts. The treatment condition introduced an integrated wearable attention aid that leveraged metacognition methods from proven military systems. The primary metric was time for nurses to respond to important alarms/alerts. Results Use of the wearable attention aid resulted in a median relative within-subject improvement for individual nurses of 118% (W = 183, p = 0.006). The top quarter of relative improvement was 3,303% faster (mean; 17.76 minutes reduced to 1.33). For all unit sessions, there was an overall 148% median faster response time to important alarms (8.12 minutes reduced to 3.27; U = 2.401, p = 0.016), with 153% median improvement in consistency across nurses (F = 11.670, p = 0.001). Discussion and conclusion Existing device-centric alarm/alert notification solutions can require too much time and effort for nurses to access and understand. As a result, nurses may ignore alarms/alerts as they focus on other important work. There has been extensive research on reducing alarm frequency in healthcare. However, alarm safety remains a top problem. Empirical observations reported here highlight the potential of improving patient safety by supporting the meta-work of checking alarms. PMID:29768477

  14. Radar detection with the Neyman-Pearson criterion using supervised-learning-machines trained with the cross-entropy error

    NASA Astrophysics Data System (ADS)

    Jarabo-Amores, María-Pilar; la Mata-Moya, David de; Gil-Pita, Roberto; Rosa-Zurera, Manuel

    2013-12-01

    The application of supervised learning machines trained to minimize the Cross-Entropy error to radar detection is explored in this article. The detector is implemented with a learning machine that implements a discriminant function, which output is compared to a threshold selected to fix a desired probability of false alarm. The study is based on the calculation of the function the learning machine approximates to during training, and the application of a sufficient condition for a discriminant function to be used to approximate the optimum Neyman-Pearson (NP) detector. In this article, the function a supervised learning machine approximates to after being trained to minimize the Cross-Entropy error is obtained. This discriminant function can be used to implement the NP detector, which maximizes the probability of detection, maintaining the probability of false alarm below or equal to a predefined value. Some experiments about signal detection using neural networks are also presented to test the validity of the study.

  15. A high-efficiency self-powered wireless sensor node for monitoring concerning vibratory events

    NASA Astrophysics Data System (ADS)

    Xu, Dacheng; Li, Suiqiong; Li, Mengyang; Xie, Danpeng; Dong, Chuan; Li, Xinxin

    2017-09-01

    This paper presents a self-powered wireless alarming sensor node (SWASN), which was designed to monitor the occurrence of concerning vibratory events. The major components of the sensor node include a vibration-threshold-triggered energy harvester (VTTEH) that powers the sensor node, a dual threshold voltage control circuit (DTVCC) for power management and a radio frequency (RF) signal transmitting module. The VTTEH generates significant electric energy only when the input vibration reaches certain amplitude. Thus, the VTTEH serves as both the power source and the vibration-event-sensing element for the sensor node. The DTVCC was specifically designed to utilize the limited power supply from the VTTEH to operate the sensor node. Constructed with only voltage detectors and MOSFETs, the DTVCC achieved low power consumption, which was 65% lower compared with the power management circuit designed in our previous work. Meanwhile, a RF transmit circuit was constructed based on the commercially available CC1110-F32 wireless transceiver chip and a compact planar antenna was designed to improve the signal transmission distance. The sensor node was fabricated and was characterized both in the laboratory and in the field. Experimental results showed that the SWASN could automatically send out alarming signals when the simulated concerning event occurred. The waiting time between two consecutive transmission periods is less than 125 s and the transmission distance can reach 1.31 km. The SWASN will have broad applications in field surveillances.

  16. The sea urchin Diadema africanum uses low resolution vision to find shelter and deter enemies.

    PubMed

    Kirwan, John D; Bok, Michael J; Smolka, Jochen; Foster, James J; Hernández, José Carlos; Nilsson, Dan-Eric

    2018-05-08

    Many sea urchins can detect light on their body surface and some species are reported to possess image-resolving vision. Here we measure the spatial resolution of vision in the long-spined sea urchin Diadema africanum , using two different visual responses: a taxis towards dark objects and an alarm response of spine-pointing towards looming stimuli. For the taxis response we used visual stimuli, which were isoluminant to the background, to discriminate spatial vision from phototaxis. Individual animals were placed in the centre of a cylindrical arena under bright down-welling light, with stimuli of varying angular width placed on the arena wall at pseudorandom directions from the centre. We tracked the direction of movement of individual animals in relation to the stimuli to determine whether the animals oriented towards the stimulus. We found that D. africanum responds by taxis towards isoluminant stimuli with a spatial resolution in the range 29°-69°. This corresponds to a theoretical acceptance angle of 38°-89°, assuming a contrast threshold of 10%. The visual acuity of the alarm response of D. africanum was tested by exposing animals to different sized dark looming and appearing stimuli on a monitor. We found that D. africanum displays a spine-pointing response to appearing black circles of 13°-25° angular width, corresponding to an acceptance angle of 60°-116°, assuming the same contrast threshold as above. © 2018. Published by The Company of Biologists Ltd.

  17. Forecasting E > 50-MeV proton events with the proton prediction system (PPS)

    NASA Astrophysics Data System (ADS)

    Kahler, Stephen W.; White, Stephen M.; Ling, Alan G.

    2017-11-01

    Forecasting solar energetic (E > 10-MeV) particle (SEP) events is an important element of space weather. While several models have been developed for use in forecasting such events, satellite operations are particularly vulnerable to higher-energy (≥50-MeV) SEP events. Here we validate one model, the proton prediction system (PPS), which extends to that energy range. We first develop a data base of E ≥ 50-MeV proton events >1.0 proton flux units (pfu) events observed on the GOES satellite over the period 1986-2016. We modify the PPS to forecast proton events at the reduced level of 1 pfu and run PPS for four different solar input parameters: (1) all ≥M5 solar X-ray flares; (2) all ≥200 sfu 8800-MHz bursts with associated ≥M5 flares; (3) all ≥500 sfu 8800-MHz bursts; and (4) all ≥5000 sfu 8800-MHz bursts. The validation contingency tables and skill scores are calculated for all groups and used as a guide to use of the PPS. We plot the false alarms and missed events as functions of solar source longitude, and argue that the longitude-dependence employed by PPS does not match modern observations. Use of the radio fluxes as the PPS driver tends to result in too many false alarms at the 500 sfu threshold, and misses more events than the soft X-ray predictor at the 5000 sfu threshold.

  18. Automated Storm Tracking and the Lightning Jump Algorithm Using GOES-R Geostationary Lightning Mapper (GLM) Proxy Data.

    PubMed

    Schultz, Elise V; Schultz, Christopher J; Carey, Lawrence D; Cecil, Daniel J; Bateman, Monte

    2016-01-01

    This study develops a fully automated lightning jump system encompassing objective storm tracking, Geostationary Lightning Mapper proxy data, and the lightning jump algorithm (LJA), which are important elements in the transition of the LJA concept from a research to an operational based algorithm. Storm cluster tracking is based on a product created from the combination of a radar parameter (vertically integrated liquid, VIL), and lightning information (flash rate density). Evaluations showed that the spatial scale of tracked features or storm clusters had a large impact on the lightning jump system performance, where increasing spatial scale size resulted in decreased dynamic range of the system's performance. This framework will also serve as a means to refine the LJA itself to enhance its operational applicability. Parameters within the system are isolated and the system's performance is evaluated with adjustments to parameter sensitivity. The system's performance is evaluated using the probability of detection (POD) and false alarm ratio (FAR) statistics. Of the algorithm parameters tested, sigma-level (metric of lightning jump strength) and flash rate threshold influenced the system's performance the most. Finally, verification methodologies are investigated. It is discovered that minor changes in verification methodology can dramatically impact the evaluation of the lightning jump system.

  19. Automated Storm Tracking and the Lightning Jump Algorithm Using GOES-R Geostationary Lightning Mapper (GLM) Proxy Data

    NASA Technical Reports Server (NTRS)

    Schultz, Elise; Schultz, Christopher Joseph; Carey, Lawrence D.; Cecil, Daniel J.; Bateman, Monte

    2016-01-01

    This study develops a fully automated lightning jump system encompassing objective storm tracking, Geostationary Lightning Mapper proxy data, and the lightning jump algorithm (LJA), which are important elements in the transition of the LJA concept from a research to an operational based algorithm. Storm cluster tracking is based on a product created from the combination of a radar parameter (vertically integrated liquid, VIL), and lightning information (flash rate density). Evaluations showed that the spatial scale of tracked features or storm clusters had a large impact on the lightning jump system performance, where increasing spatial scale size resulted in decreased dynamic range of the system's performance. This framework will also serve as a means to refine the LJA itself to enhance its operational applicability. Parameters within the system are isolated and the system's performance is evaluated with adjustments to parameter sensitivity. The system's performance is evaluated using the probability of detection (POD) and false alarm ratio (FAR) statistics. Of the algorithm parameters tested, sigma-level (metric of lightning jump strength) and flash rate threshold influenced the system's performance the most. Finally, verification methodologies are investigated. It is discovered that minor changes in verification methodology can dramatically impact the evaluation of the lightning jump system.

  20. Automated Storm Tracking and the Lightning Jump Algorithm Using GOES-R Geostationary Lightning Mapper (GLM) Proxy Data

    PubMed Central

    SCHULTZ, ELISE V.; SCHULTZ, CHRISTOPHER J.; CAREY, LAWRENCE D.; CECIL, DANIEL J.; BATEMAN, MONTE

    2017-01-01

    This study develops a fully automated lightning jump system encompassing objective storm tracking, Geostationary Lightning Mapper proxy data, and the lightning jump algorithm (LJA), which are important elements in the transition of the LJA concept from a research to an operational based algorithm. Storm cluster tracking is based on a product created from the combination of a radar parameter (vertically integrated liquid, VIL), and lightning information (flash rate density). Evaluations showed that the spatial scale of tracked features or storm clusters had a large impact on the lightning jump system performance, where increasing spatial scale size resulted in decreased dynamic range of the system’s performance. This framework will also serve as a means to refine the LJA itself to enhance its operational applicability. Parameters within the system are isolated and the system’s performance is evaluated with adjustments to parameter sensitivity. The system’s performance is evaluated using the probability of detection (POD) and false alarm ratio (FAR) statistics. Of the algorithm parameters tested, sigma-level (metric of lightning jump strength) and flash rate threshold influenced the system’s performance the most. Finally, verification methodologies are investigated. It is discovered that minor changes in verification methodology can dramatically impact the evaluation of the lightning jump system. PMID:29303164

  1. Strategies to increase smoke alarm use in high-risk households.

    PubMed

    Harvey, Pauline A; Aitken, Mary; Ryan, George W; Demeter, Lori A; Givens, Jeanne; Sundararaman, Ramya; Goulette, Scott

    2004-10-01

    A 3-year project was undertaken to evaluate two methods of promoting residential smoke alarm installation and maintenance in high risk households across the U.S. Five states (Arkansas, Maine, Maryland, Massachusetts, and North Carolina) participated. The two strategies under study were direct installation of smoke alarms and distribution of a voucher for free smoke alarms. The target population included occupants of high-risk households without working smoke alarms who were approached as part of a door-to-door canvassing program. Fire Safety education was provided to both groups. A follow up assessment conducted 6-12 months post intervention assessed the presence and functional status of smoke alarms in each of the two groups. Demographic and fire safety data were also collected at baseline and follow up for each group. 4,455 households were enrolled in the study [Installation Group: 2,206 (49.5%), Voucher Group: 2,249 (50.5%)]. Baseline characteristics of the groups within each state were comparable. Follow up data was obtained on 1,583 installation group households and 1,545 voucher group households. At follow up, 1,421 (89.8%) households in the installation group had working smoke alarms, compared with 997 (65%) households in the voucher group, Odds Ratio 4.82 (95% CI=3.97, 5.85) (p <.0001). On average, 47% of all households enrolled in the voucher group did not redeem their vouchers (range 26-63%). Direct installation of alarms by program staff resulted in working smoke alarms in 90% of households receiving the direct installation intervention. Only 65% of voucher households had functioning alarms at follow up, largely due to failure to redeem vouchers.

  2. Radiation Detection at Borders for Homeland Security

    NASA Astrophysics Data System (ADS)

    Kouzes, Richard

    2004-05-01

    Countries around the world are deploying radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders at land, rail, air, and sea ports of entry. These efforts include deployments in the US and a number of European and Asian countries by governments and international agencies. Items of concern include radiation dispersal devices (RDD), nuclear warheads, and special nuclear material (SNM). Radiation portal monitors (RPMs) are used as the main screening tool for vehicles and cargo at borders, supplemented by handheld detectors, personal radiation detectors, and x-ray imaging systems. Some cargo contains naturally occurring radioactive material (NORM) that triggers "nuisance" alarms in RPMs at these border crossings. Individuals treated with medical radiopharmaceuticals also produce nuisance alarms and can produce cross-talk between adjacent lanes of a multi-lane deployment. The operational impact of nuisance alarms can be significant at border crossings. Methods have been developed for reducing this impact without negatively affecting the requirements for interdiction of radioactive materials of interest. Plastic scintillator material is commonly used in RPMs for the detection of gamma rays from radioactive material, primarily due to the efficiency per unit cost compared to other detection materials. The resolution and lack of full-energy peaks in the plastic scintillator material prohibits detailed spectroscopy. However, the limited spectroscopic information from plastic scintillator can be exploited to provide some discrimination. Energy-based algorithms used in RPMs can effectively exploit the crude energy information available from a plastic scintillator to distinguish some NORM. Whenever NORM cargo limits the level of the alarm threshold, energy-based algorithms produce significantly better detection probabilities for small SNM sources than gross-count algorithms. This presentation discusses experience with RPMs for interdiction of radioactive materials at borders.

  3. Development of a Low Cost Earthquake Early Warning System in Taiwan

    NASA Astrophysics Data System (ADS)

    Wu, Y. M.

    2017-12-01

    The National Taiwan University (NTU) developed an earthquake early warning (EEW) system for research purposes using low-cost accelerometers (P-Alert) since 2010. As of 2017, a total of 650 stations have been deployed and configured. The NTU system can provide earthquake information within 15 s of an earthquake occurrence. Thus, this system may provide early warnings for cities located more than 50 km from the epicenter. Additionally, the NTU system also has an onsite alert function that triggers a warning for incoming P-waves greater than a certain magnitude threshold, thus providing a 2-3 s lead time before peak ground acceleration (PGA) for regions close to an epicenter. Detailed shaking maps are produced by the NTU system within one or two minutes after an earthquake. Recently, a new module named ShakeAlarm has been developed. Equipped with real-time acceleration signals and the time-dependent anisotropic attenuation relationship of the PGA, ShakingAlarm can provide an accurate PGA estimation immediately before the arrival of the observed PGA. This unique advantage produces sufficient lead time for hazard assessment and emergency response, which is unavailable for traditional shakemap, which are based on only the PGA observed in real time. The performance of ShakingAlarm was tested with six M > 5.5 inland earthquakes from 2013 to 2016. Taking the 2016 M6.4 Meinong earthquake simulation as an example, the predicted PGA converges to a stable value and produces a predicted shake map and an isocontour map of the predicted PGA within 16 seconds of earthquake occurrence. Compared with traditional regional EEW system, ShakingAlarm can effectively identify possible damage regions and provide valuable early warning information (magnitude and PGA) for risk mitigation.

  4. Investigating Over Critical Thresholds of Forest Megafires Danger Conditions in Europe Utilising the ECMWF ERA-Interim Reanalysis

    NASA Astrophysics Data System (ADS)

    Petroliagkis, Thomas I.; Camia, Andrea; Liberta, Giorgio; Durrant, Tracy; Pappenberger, Florian; San-Miguel-Ayanz, Jesus

    2014-05-01

    The European Forest Fire Information System (EFFIS) has been established by the Joint Research Centre (JRC) and the Directorate General for Environment (DG ENV) of the European Commission (EC) to support the services in charge of the protection of forests against fires in the EU and neighbour countries, and also to provide the EC services and the European Parliament with information on forest fires in Europe. Within its applications, EFFIS provides current and forecast meteorological fire danger maps up to 6 days. Weather plays a key role in affecting wildfire occurrence and behaviour. Meteorological parameters can be used to derive meteorological fire weather indices that provide estimations of fire danger level at a given time over a specified area of interest. In this work, we investigate the suitability of critical thresholds of fire danger to provide an early warning for megafires (fires > 500 ha) over Europe. Past trends of fire danger are analysed computing daily fire danger from weather data taken from re-analysis fields for a period of 31 years (1980 to 2010). Re-analysis global data sets coming from the construction of high-quality climate records, which combine past observations collected from many different observing and measuring platforms, are capable of describing how Fire Danger Indices have evolved over time at a global scale. The latest and most updated ERA-Interim dataset of the European Centre for Medium-Range Weather Forecast (ECMWF) was used to extract meteorological variables needed to compute daily values of the Canadian Fire Weather Index (CFWI) over Europe, with a horizontal resolution of about 75x75 km. Daily time series of CFWI were constructed and analysed over a total of 1,071 European NUTS3 centroids, resulting in a set of percentiles and critical thresholds. Such percentiles could be used as thresholds to help fire services establish a measure of the significance of CFWI outputs as they relate to levels of fire potential, fuel conditions and fire danger. Median percentile values of fire days accumulated over the 31-year period were compared to median values of all days from that period. As expected, the CWFI time series exhibit different values on fire days than on all days. In addition, a percentile analysis was performed in order to determine the behaviour of index values corresponding to fire events falling into the megafire category. This analysis resulted in a set of critical thresholds based on percentiles. By utilising such thresholds, an initial framework of an early warning system has being established. By lowering the value of any of these thresholds, the number of hits could be increased until all extremes were captured (resulting in zero misses). However, in doing so, the number of false alarms tends to increase significantly. Consequently, an optimal trade-off between hits and false alarms has to be established when setting different (critical) CFWI thresholds.

  5. Development of an Accident Reproduction Simulator System Using a Hemodialysis Extracorporeal Circulation System

    PubMed Central

    Nishite, Yoshiaki; Takesawa, Shingo

    2016-01-01

    Background: Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. Objectives: The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. Materials and Methods: In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. Results: The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Conclusions: Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training. PMID:26981503

  6. Evaluation of pre-hospital transport time of stroke patients to thrombolytic treatment.

    PubMed

    Simonsen, Sofie Amalie; Andresen, Morten; Michelsen, Lene; Viereck, Søren; Lippert, Freddy K; Iversen, Helle Klingenberg

    2014-11-13

    Effective treatment of stroke is time dependent. Pre-hospital management is an important link in reducing the time from occurrence of stroke symptoms to effective treatment. The aim of this study was to evaluate time used by emergency medical services (EMS) for stroke patients during a five-year period in order to identify potential delays and evaluate the reorganization of EMS in Copenhagen in 2009. We performed a retrospective analysis of ambulance records from stroke patients suitable for thrombolysis from 1 January 2006 to 7 July 2011. We noted response time from dispatch of the ambulance to arrival at the scene, on-scene time and transport time to the hospital-in total, alarm-to-door time. In addition, we noted baseline characteristics. We reviewed 481 records (58% male, median age 66 years). The median (IQR) alarm-to-door time in minutes was 41 (33-52), of which 18 (12-24) minutes were spent on scene. Response time was reduced from the period before to the period after reorganization (7 vs. 5 minutes, p <0.001). In a linear multiple regression model, higher patient age and longer distance to the hospital correlated with significantly longer transportation time (p <0.001). This study shows an unchanged alarm-to-door time of 41 minutes over a five-year period. Response time, but not total alarm-to-door time, was reduced during the five years. On-scene time constituted nearly half of the total alarm-to-door time and is thus a point of focus for improvement.

  7. The impact of recent changes in smoke alarm legislation on residential fire injuries and smoke alarm ownership in New South Wales, Australia.

    PubMed

    Harvey, Lara A; Poulos, Roslyn G; Sherker, Shauna

    2013-01-01

    In 2006, New South Wales (NSW) state legislation changed from requiring smoke alarms in new houses only to all houses. We evaluated the impact of this legislative change on residential fire injury and smoke alarm ownership characteristics. Residential fire injuries for 2002 to 2010 were identified from hospitalization data for all hospitals in NSW. Data relating to smoke alarm ownership and demographic factors were obtained from the NSW Population Health Survey. Negative binomial regression analysis was used to analyze trends over time. Prior to the introduction of universal legislation, hospitalization rates were increasing slightly; however, following the introduction of legislation, hospitalization rates decreased by an estimated 36.2% (95% confidence interval [CI], 16.7-55.8) annually. Smoke alarm ownership increased from 73.3% (95% CI, 72.5-74.2) prelegislation to 93.6% (95% CI, 93.1-94.2) 18 months postlegislation. Thirty percent of households reported testing their alarms regularly. Speaking a language other than English (relative risks [RRs], 1.82; 95% CI, 1.44-2.99), allowing smoking in the home (RR, 1.73; 95% CI, 1.31-2.27), and being part of the most disadvantaged socioeconomic group (RR, 1.47; 95% CI, 1.14-1.91) remain major risk factors for nonownership. Broadening the scope of state legislation has had a positive impact on residential fire-related hospitalizations and smoke alarm ownership. However, it is of concern that the legislation has been the least effective in increasing smoke alarm ownership among non-English-speaking households, in households where smoking is allowed, in low socioeconomic households, and that a high proportion of householders do not test their smoke alarms regularly. Targeted campaigns are needed to reach these high-risk groups and to ensure that smoke alarms are functional.

  8. [Evaluation of the analyzer of hematology Beckman Coulter® HmX™ in the university hospital of Oran].

    PubMed

    Zmouli, N; Moulasserdoun, K; Seghier, F

    2013-11-01

    The choice of an automaton of haematology is a determining stage, which has to take into account at the same time the quality of the results and the economic imperatives: workload, structure and organization of the laboratory. [corrected] It is in this spirit that we estimated during a period of 3 months the analyzer of haematology: the HmX™ Coulter with boatman of samples of the company Beckman. This automaton realizes the blood numeration, the formula leukocytic and the reticulocyte count. At first, we estimated the appropriate characteristics of device. Secondly, we estimated the relevance, the sensibility and the specificity of the alarms by comparing with the reference method, which is the optical microscopy. For that purpose, 125 blood smears resulting from service of haematology and from resuscitation were examined in optical microscopy. The technical tests were realized according to the recommendations of the International committee for evaluation of automatons of haematology. The analytical performances were satisfactory in particular the big interval of linearity and the absence of contamination. As regards the evaluation of the alarms system: rate of rejection is 63%, the sensibility 86%, the specificity 70%, the positive predictive value 80%, the negative predictive value 78% and the efficiency 80%. The alarms myelaemia and atypical lymphocytes were never sources of false negatives. The alarms erythroblasts and platelet aggregates did not engendered positive forgery. The blast cell alarm was responsible for a single case of false negative. The faithfulness of automaton is satisfactory: the absence of contamination, the big interval of linearity for the leukocytes, the red blood cells and the platelets as well as a good relevance of the alarms with regard to the anomalies found on the peripheral blood smear. From the user-friendliness and practicability point of view, the HmX™ Coulter was deeply appreciated. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  9. Assessment of precursory information in seismo-electromagnetic phenomena

    NASA Astrophysics Data System (ADS)

    Han, P.; Hattori, K.; Zhuang, J.

    2017-12-01

    Previous statistical studies showed that there were correlations between seismo-electromagnetic phenomena and sizeable earthquakes in Japan. In this study, utilizing Molchan's error diagram, we evaluate whether these phenomena contain precursory information and discuss how they can be used in short-term forecasting of large earthquake events. In practice, for given series of precursory signals and related earthquake events, each prediction strategy is characterized by the leading time of alarms, the length of alarm window, the alarm radius (area) and magnitude. The leading time is the time length between a detected anomaly and its following alarm, and the alarm window is the duration that an alarm lasts. The alarm radius and magnitude are maximum predictable distance and minimum predictable magnitude of earthquake events, respectively. We introduce the modified probability gain (PG') and the probability difference (D') to quantify the forecasting performance and to explore the optimal prediction parameters for a given electromagnetic observation. The above methodology is firstly applied to ULF magnetic data and GPS-TEC data. The results show that the earthquake predictions based on electromagnetic anomalies are significantly better than random guesses, indicating the data contain potential useful precursory information. Meanwhile, we reveal the optimal prediction parameters for both observations. The methodology proposed in this study could be also applied to other pre-earthquake phenomena to find out whether there is precursory information, and then on this base explore the optimal alarm parameters in practical short-term forecast.

  10. Inpatient-Derived Vital Sign Parameters Implementation: An Initiative to Decrease Alarm Burden.

    PubMed

    Kipps, Alaina K; Poole, Sarah F; Slaney, Cheryl; Feehan, Shannon; Longhurst, Christopher A; Sharek, Paul J; Goel, Veena V

    2017-08-01

    To implement data-driven vital sign parameters to reduce bedside monitor alarm burden. Single-center, quality-improvement initiative with historical controls assessing the impact of age-based, inpatient-derived heart rate (HR) and respiratory rate (RR) parameters on a 20-bed acute care ward that serves primarily pediatric cardiology patients. The primary outcome was the number of alarms per monitored bed day (MBD) with the aim to decrease the alarms per MBD. Balancing measures included the frequency of missed rapid response team activations, acute respiratory code events, and cardiorespiratory arrest events in the unit with the new vital sign parameters. The median number of all cardiorespiratory monitor alarms per MBD decreased by 21% from 52 (baseline period) to 41 (postintervention period) ( P < .001). This included a 17% decrease in the median HR alarms (9-7.5 per MBD) and a 53% drop in RR alarms (16.8-8.0 per MBD). There were 57 rapid response team activations, 8 acute respiratory code events, and no cardiorespiratory arrest events after the implementation of the new parameters. An evaluation of HRs and RRs recorded at the time of the event revealed that all patients with HRs and/or RRs out of range per former default parameters would also be out of range with the new parameters. Implementation of data-driven HR and iteratively derived RR parameters safely decreased the total alarm frequency by 21% in a pediatric acute care unit. Copyright © 2017 by the American Academy of Pediatrics.

  11. Establishing seasonal and alert influenza thresholds in Cambodia using the WHO method: implications for effective utilization of influenza surveillance in the tropics and subtropics.

    PubMed

    Ly, Sovann; Arashiro, Takeshi; Ieng, Vanra; Tsuyuoka, Reiko; Parry, Amy; Horwood, Paul; Heng, Seng; Hamid, Sarah; Vandemaele, Katelijn; Chin, Savuth; Sar, Borann; Arima, Yuzo

    2017-01-01

    To establish seasonal and alert thresholds and transmission intensity categories for influenza to provide timely triggers for preventive measures or upscaling control measures in Cambodia. Using Cambodia's influenza-like illness (ILI) and laboratory-confirmed influenza surveillance data from 2009 to 2015, three parameters were assessed to monitor influenza activity: the proportion of ILI patients among all outpatients, proportion of ILI samples positive for influenza and the product of the two. With these parameters, four threshold levels (seasonal, moderate, high and alert) were established and transmission intensity was categorized based on a World Health Organization alignment method. Parameters were compared against their respective thresholds. Distinct seasonality was observed using the two parameters that incorporated laboratory data. Thresholds established using the composite parameter, combining syndromic and laboratory data, had the least number of false alarms in declaring season onset and were most useful in monitoring intensity. Unlike in temperate regions, the syndromic parameter was less useful in monitoring influenza activity or for setting thresholds. Influenza thresholds based on appropriate parameters have the potential to provide timely triggers for public health measures in a tropical country where monitoring and assessing influenza activity has been challenging. Based on these findings, the Ministry of Health plans to raise general awareness regarding influenza among the medical community and the general public. Our findings have important implications for countries in the tropics/subtropics and in resource-limited settings, and categorized transmission intensity can be used to assess severity of potential pandemic influenza as well as seasonal influenza.

  12. Evaluation of Neutron Response of Criticality Accident Alarm System Detector to Quasi-Monoenergetic 24 keV Neutrons

    NASA Astrophysics Data System (ADS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Yashima, Hiroshi

    The criticality accident alarm system (CAAS), which was recently developed and installed at the Japan Atomic Energy Agency's Tokai Reprocessing Plant, consists of a plastic scintillator combined with a cadmium-lined polyethylene moderator and thereby responds to both neutrons and gamma rays. To evaluate the neutron absorbed dose rate response of the CAAS detector, a 24 keV quasi-monoenergetic neutron irradiation experiment was performed at the B-1 facility of the Kyoto University Research Reactor. The detector's evaluated neutron response was confirmed to agree reasonably well with prior computer-predicted responses.

  13. Detection of laryngeal function using speech and electroglottographic data.

    PubMed

    Childers, D G; Bae, K S

    1992-01-01

    The purpose of this research was to develop quantitative measures for the assessment of laryngeal function using speech and electroglottographic (EGG) data. We developed two procedures for the detection of laryngeal pathology: 1) a spectral distortion measure using pitch synchronous and asynchronous methods with linear predictive coding (LPC) vectors and vector quantization (VQ) and 2) analysis of the EGG signal using time interval and amplitude difference measures. The VQ procedure was conjectured to offer the possibility of circumventing the need to estimate the glottal volume velocity wave-form by inverse filtering techniques. The EGG procedure was to evaluate data that was "nearly" a direct measure of vocal fold vibratory motion and thus was conjectured to offer the potential for providing an excellent assessment of laryngeal function. A threshold based procedure gave 75.9 and 69.0% probability of pathological detection using procedures 1) and 2), respectively, for 29 patients with pathological voices and 52 normal subjects. The false alarm probability was 9.6% for the normal subjects.

  14. Video performance for high security applications.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connell, Jack C.; Norman, Bradley C.

    2010-06-01

    The complexity of physical protection systems has increased to address modern threats to national security and emerging commercial technologies. A key element of modern physical protection systems is the data presented to the human operator used for rapid determination of the cause of an alarm, whether false (e.g., caused by an animal, debris, etc.) or real (e.g., a human adversary). Alarm assessment, the human validation of a sensor alarm, primarily relies on imaging technologies and video systems. Developing measures of effectiveness (MOE) that drive the design or evaluation of a video system or technology becomes a challenge, given the subjectivitymore » of the application (e.g., alarm assessment). Sandia National Laboratories has conducted empirical analysis using field test data and mathematical models such as binomial distribution and Johnson target transfer functions to develop MOEs for video system technologies. Depending on the technology, the task of the security operator and the distance to the target, the Probability of Assessment (PAs) can be determined as a function of a variety of conditions or assumptions. PAs used as an MOE allows the systems engineer to conduct trade studies, make informed design decisions, or evaluate new higher-risk technologies. This paper outlines general video system design trade-offs, discusses ways video can be used to increase system performance and lists MOEs for video systems used in subjective applications such as alarm assessment.« less

  15. Smoke alarms for sleeping adults who are hard-of-hearing: comparison of auditory, visual, and tactile signals.

    PubMed

    Bruck, Dorothy; Thomas, Ian R

    2009-02-01

    People who are hard-of-hearing may rely on auditory, visual, or tactile alarms in a fire emergency, and US standards require strobe lights in hotel bedrooms to provide emergency notification for people with hearing loss. This is the first study to compare the waking effectiveness of a variety of auditory (beeps), tactile (bed and pillow shakers), and visual (strobe lights) signals at a range of intensities. Three auditory signals, a bed shaker, a pillow shaker, and strobe lights were presented to 38 adults (aged 18 to 80 yr) with mild to moderately severe hearing loss of 25 to 70 dB (in both ears), during slow-wave sleep (deep sleep). Two of the auditory signals were selected on the basis that they had the lowest auditory thresholds when awake (from a range of eight signals). The third auditory signal was the current 3100-Hz smoke alarm. All auditory signals were tested below, at, and above the decibel level prescribed by the applicable standard for bedrooms (75 dBA). In the case of bed and pillow shakers intensities below, at, and above the level as purchased were tested. For strobe lights three levels were used, all of which were above the applicable standard. The intensity level at which participants awoke was identified by electroencephalograph monitoring. The most effective signal was a 520-Hz square wave auditory signal, waking 92% at 75 dBA, compared with 56% waking to the 75 dBA high-pitched alarm. Bed and pillow shakers awoke 80 to 84% at the intensity level as purchased. The strobe lights awoke only 27% at an intensity above the US standard. Nonparametric analyses confirmed that the 520-Hz square wave signal was significantly more effective than the current smoke alarm and the strobe lights in waking this population. A low-frequency square wave signal has now been found to be significantly more effective than all tested alternatives in a number of populations (hard-of-hearing, children, older adults, young adults, alcohol impaired) and should be adopted across the whole population as the normal smoke alarm signal. Strobe lights, even at high intensities, are ineffective in reliably waking people with mild to moderate hearing loss.

  16. Automated segmentation of linear time-frequency representations of marine-mammal sounds.

    PubMed

    Dadouchi, Florian; Gervaise, Cedric; Ioana, Cornel; Huillery, Julien; Mars, Jérôme I

    2013-09-01

    Many marine mammals produce highly nonlinear frequency modulations. Determining the time-frequency support of these sounds offers various applications, which include recognition, localization, and density estimation. This study introduces a low parameterized automated spectrogram segmentation method that is based on a theoretical probabilistic framework. In the first step, the background noise in the spectrogram is fitted with a Chi-squared distribution and thresholded using a Neyman-Pearson approach. In the second step, the number of false detections in time-frequency regions is modeled as a binomial distribution, and then through a Neyman-Pearson strategy, the time-frequency bins are gathered into regions of interest. The proposed method is validated on real data of large sequences of whistles from common dolphins, collected in the Bay of Biscay (France). The proposed method is also compared with two alternative approaches: the first is smoothing and thresholding of the spectrogram; the second is thresholding of the spectrogram followed by the use of morphological operators to gather the time-frequency bins and to remove false positives. This method is shown to increase the probability of detection for the same probability of false alarms.

  17. Why Waveform Correlation Sometimes Fails

    NASA Astrophysics Data System (ADS)

    Carmichael, J.

    2015-12-01

    Waveform correlation detectors used in explosion monitoring scan noisy geophysical data to test two competing hypotheses: either (1) an amplitude-scaled version of a template waveform is present, or, (2) no signal is present at all. In reality, geophysical wavefields that are monitored for explosion signatures include waveforms produced by non-target sources that are partially correlated with the waveform template. Such signals can falsely trigger correlation detectors, particularly at low thresholds required to monitor for smaller target explosions. This challenge is particularly formidable when monitoring known test sites for seismic disturbances, since uncatalogued natural seismicity is (generally) more prevalent at lower magnitudes, and could be mistaken for small explosions. To address these challenges, we identify real examples in which correlation detectors targeting explosions falsely trigger on both site-proximal earthquakes (Figure 1, below) and microseismic "noise". Motivated by these examples, we quantify performance loss when applying these detectors, and re-evaluate the correlation-detector's hypothesis test. We thereby derive new detectors from more general hypotheses that admit unknown background seismicity, and apply these to real data. From our treatment, we derive "rules of thumb'' for proper template and threshold selection in heavily cluttered signal environments. Last, we answer the question "what is the probability of falsely detecting an earthquake collocated at a test site?", using correlation detectors that include explosion-triggered templates. Figure Top: An eight-channel data stream (black) recorded from an earthquake near a mine. Red markers indicate a detection. Middle: The correlation statistic computed by scanning the template against the data stream at top. The red line indicates the threshold for event declaration, determined by a false-alarm on noise probability constraint, as computed from the signal-absent distribution using the Neyman Pearson criteria. Bottom: The histogram of the correlation statistic time series (gray) superimposed on the theoretical null distribution (black curve). The line shows the threshold, consistent with a right-tail probability, computed from the black curve.

  18. Modelling the Future Hydroclimatology of the Lower Fraser River and its Impacts on the Spawning Migration Survival of Sockeye Salmon

    NASA Technical Reports Server (NTRS)

    Hague, M. J.; Ferrari, M. R.; Miller, J. R.; Patterson, D. A.; Russell, G. L.; Farrell, A.P.; Hinch, S. G.

    2010-01-01

    Short episodic high temperature events can be lethal for migrating adult Pacific salmon (Oncorhynchus spp.). We downscaled temperatures for the Fraser River, British Columbia to evaluate the impact of climate warming on the frequency of exceeding thermal thresholds associated with salmon migratory success. Alarmingly, a modest 1.0 C increase in average summer water temperature over 100 years (1981-2000 to 2081-2100) tripled the number of days per year exceeding critical salmonid thermal thresholds (i.e. 19.0 C). Refined thresholds for two populations (Gates Creek and Weaver Creek) of sockeye salmon (Oncorhynchus nerka) were defined using physiological constraint models based on aerobic scope. While extreme temperatures leading to complete aerobic collapse remained unlikely under our warming scenario, both populations were increasingly forced to migrate upriver at reduced levels of aerobic performance (e.g. in 80% of future simulations, => 90% of salmon encountered temperatures exceeding population specific thermal optima for maximum aerobic scope; T(sub opt)) = 16.3 C for Gates Creek and T(sub sopt)=14.5 C for Weaver Creek). Assuming recent changes to river entry timing persist, we also predicted dramatic increases in the probability of freshwater mortality for Weaver Creek salmon due to reductions in aerobic, and general physiological, performance (e.g. in 42% of future simulations =>50% of Weaver Creek fish exceeded temperature thresholds associated with 0 - 60% of maximum aerobic scope). Potential for adaptation via directional selection on run-timing was more evident for the Weaver Creek population. Early entry Weaver Creek fish experienced 25% (range: 15 - 31%) more suboptimal temperatures than late entrants, compared with an 8% difference (range: 0 - 17%) between early and late Gates Creek fish. Our results emphasize the need to consider daily temperature variability in association with population-specific differences in behaviour and physiological constraints when forecasting impacts of climate change on migratory survival of aquatic species.

  19. Over-reassurance and undersupport after a 'false alarm': a systematic review of the impact on subsequent cancer symptom attribution and help seeking.

    PubMed

    Renzi, Cristina; Whitaker, Katriina L; Wardle, Jane

    2015-02-04

    This literature review examined research into the impact of a previous 'all-clear' or non-cancer diagnosis following symptomatic presentation ('false alarm') on symptom attribution and delays in help seeking for subsequent possible cancer symptoms. The comprehensive literature review included original research based on quantitative, qualitative and mixed data collection methods. We used a combination of search strategies, including in-depth searches of electronic databases (PubMed, EMBASE, PsychInfo), searching key authors and articles listed as 'related' in PubMed, and reference lists. We performed a narrative synthesis of key themes shared across studies. The review included studies published after 1990 and before February 2014 reporting information on adult patients having experienced a false alarm following symptomatic presentation. We excluded false alarms in the context of screening. We evaluated the effect of a 'false alarm' on symptom attribution and help seeking for new or recurrent possible cancer symptoms. Overall, 1442 papers were screened and 121 retrieved for full-text evaluation. Among them, 19 reported on false alarms and subsequent symptom attribution or help seeking. They used qualitative (n=14), quantitative (n=3) and mixed methods (n=2). Breast (n=7), gynaecological (n=3), colorectal (n=2), testicular (n=2), and head and neck cancers (n=2) were the most studied. Two broad themes emerged underlying delays in help seeking: (1) over-reassurance from the previous 'all-clear' diagnosis leading to subsequent symptoms being interpreted as benign, and (2) unsupportive healthcare experiences in which symptoms were dismissed, leaving patients concerned about appearing hypochondriacal or uncertain about the appropriate next actions. The evidence suggested that the effect of a false alarm can persist for months and even years. In conclusion, over-reassurance and undersupport of patients after a false alarm can undermine help seeking in the case of new or recurrent potential cancer symptoms, highlighting the need for appropriate patient information when investigations rule out cancer. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Ranking ICME's efficiency for geomagnetic and ionospheric storms and risk of false alarms

    NASA Astrophysics Data System (ADS)

    Gulyaeva, T. L.

    2017-11-01

    A statistical analysis is undertaken on ICME's efficiency in producing the geomagnetic and ionospheric storms. The mutually-consistent thresholds for the intense, moderate and weak space weather storms and quiet conditions are introduced with an analytical model based on relations between the equatorial Dst index and geomagnetic indices AE, aa, ap, ap(τ) and the ionospheric Vσ indices. The ionosphere variability Vσ index is expressed in terms of the total electron content (TEC) deviation from the -15-day sliding median normalized by the standard deviation for the 15 preceding days. The intensity of global positive ionospheric storm, Vσp, and negative storm, Vσn, is represented by the relative density of anomalous ±Vσ index occurrence derived from the global ionospheric maps GIM-TEC for 1999-2016. An impact of total 421 ICME events for 1999-2016 on the geomagnetic and ionospheric storms expressed by AE, Dst, aa, ap, ap(τ), Vσp, Vσn indices and their superposition is analyzed using ICME catalogue by Richardson and Cane (2010) during 24 h after the ICME start time t0. Hierarchy of efficiency of ICME → storm relation is established. The ICMEs have a higher probability (22-25%) to be followed by the intense ionospheric and auroral electrojet storms at global and high latitudes as compared to the intense storms at middle and low latitudes (18-20%) and to moderate and weak storms at high latitudes (5-17%). At the same time ICMEs are more effective in producing the moderate storms (24-28%) at the middle and low latitudes as compared to the intense and weak storms at these latitudes (13-22%) and to moderate storms at high latitudes (8-17%). The remaining cases when quiet conditions are observed after ICMEs present higher chance for a false alarm. The risk factor for a false alarm can vary from 18% if the superposition of all indices is considered, to 51-64% for individual AE, Vσp and Vσn indices. The analysis indicates that the mutually-consistent thresholds can be successfully applied to the external sources of the geomagnetic and ionospheric storms other than ICME which present challenge for the further investigation.

  1. Design of Alarm Sound of Home Care Equipment Based on Age-related Auditory Sense

    NASA Astrophysics Data System (ADS)

    Shibano, Jun-Ichi; Tadano, Shigeru; Kaneko, Hirotaka

    A wide variety of home care equipment has been developed to support the independent lifestyle and care taking of elderly persons. Almost all of the equipment has an alarm designed to alert a care person or to sound a warning in case of an emergency. Due to the fact that aging human beings' senses physiologically, weaken and deteriorate, each alarm's sound must be designed to account for the full range of elderly person's hearing loss. Since the alarms are usually heard indoors, it is also necessary to evaluate the relationship between the basic characteristics of the sounds and living area's layout. In this study, we investigated the sounds of various alarms of the home care equipment based on both the age-related hearing characteristics of elderly persons and the propagation property of the sounds indoors. As a result, it was determined that the hearing characteristics of elderly persons are attuned to sounds which have a frequency from 700Hz to 1kHz, and it was learned that the indoor absorption ratio of sound is smallest when the frequency is 1kHz. Therefore, a frequency of 1kHz is good for the alarm sound of home care equipment. A flow chart to design the alarm sound of home care equipment was proposed, taking into account the extent of age-related auditory sense deterioration.

  2. An analysis of I/O efficient order-statistic-based techniques for noise power estimation in the HRMS sky survey's operational system

    NASA Technical Reports Server (NTRS)

    Zimmerman, G. A.; Olsen, E. T.

    1992-01-01

    Noise power estimation in the High-Resolution Microwave Survey (HRMS) sky survey element is considered as an example of a constant false alarm rate (CFAR) signal detection problem. Order-statistic-based noise power estimators for CFAR detection are considered in terms of required estimator accuracy and estimator dynamic range. By limiting the dynamic range of the value to be estimated, the performance of an order-statistic estimator can be achieved by simpler techniques requiring only a single pass of the data. Simple threshold-and-count techniques are examined, and it is shown how several parallel threshold-and-count estimation devices can be used to expand the dynamic range to meet HRMS system requirements with minimal hardware complexity. An input/output (I/O) efficient limited-precision order-statistic estimator with wide but limited dynamic range is also examined.

  3. Coincidence probabilities for spacecraft gravitational wave experiments - Massive coalescing binaries

    NASA Technical Reports Server (NTRS)

    Tinto, Massimo; Armstrong, J. W.

    1991-01-01

    Massive coalescing binary systems are candidate sources of gravitational radiation in the millihertz frequency band accessible to spacecraft Doppler tracking experiments. This paper discusses signal processing and detection probability for waves from coalescing binaries in the regime where the signal frequency increases linearly with time, i.e., 'chirp' signals. Using known noise statistics, thresholds with given false alarm probabilities are established for one- and two-spacecraft experiments. Given the threshold, the detection probability is calculated as a function of gravitational wave amplitude for both one- and two-spacecraft experiments, assuming random polarization states and under various assumptions about wave directions. This allows quantitative statements about the detection efficiency of these experiments and the utility of coincidence experiments. In particular, coincidence probabilities for two-spacecraft experiments are insensitive to the angle between the directions to the two spacecraft, indicating that near-optical experiments can be done without constraints on spacecraft trajectories.

  4. Minimum Energy-Variance Filters for the detection of compact sources in crowded astronomical images

    NASA Astrophysics Data System (ADS)

    Herranz, D.; Sanz, J. L.; López-Caniego, M.; González-Nuevo, J.

    2006-10-01

    In this paper we address the common problem of the detection and identification of compact sources, such as stars or far galaxies, in Astronomical images. The common approach, that consist in applying a matched filter to the data in order to remove noise and to search for intensity peaks above a certain detection threshold, does not work well when the sources to be detected appear in large number over small regions of the sky due to the effect of source overlapping and interferences among the filtered profiles of the sources. A new class of filter that balances noise removal with signal spatial concentration is introduced, then it is applied to simulated astronomical images of the sky at 857 GHz. We show that with the new filter it is possible to improve the ratio between true detections and false alarms with respect to the matched filter. For low detection thresholds, the improvement is ~ 40%.

  5. A smart microelectromechanical sensor and switch triggered by gas

    NASA Astrophysics Data System (ADS)

    Bouchaala, Adam; Jaber, Nizar; Shekhah, Osama; Chernikova, Valeriya; Eddaoudi, Mohamed; Younis, Mohammad I.

    2016-07-01

    There is an increasing interest to realize smarter sensors and actuators that can deliver a multitude of sophisticated functionalities while being compact in size and of low cost. We report here combining both sensing and actuation on the same device based on a single microstructure. Specifically, we demonstrate a smart resonant gas (mass) sensor, which in addition to being capable of quantifying the amount of absorbed gas, can be autonomously triggered as an electrical switch upon exceeding a preset threshold of absorbed gas. Toward this, an electrostatically actuated polymer microbeam is fabricated and is then functionalized with a metal-organic framework, namely, HKUST-1. The microbeam is demonstrated to absorb vapors up to a certain threshold, after which is shown to collapse through the dynamic pull-in instability. Upon pull-in, the microstructure can be made to act as an electrical switch to achieve desirable actions, such as alarming.

  6. Blood leak alarm interference by hydoxocobalamin is hemodialysis machine dependent.

    PubMed

    Sutter, M E; Clarke, M E; Cobb, J; Daubert, G P; Rathore, V S; Aston, L S; Poppenga, R H; Ford, J B; Owen, K P; Albertson, T E

    2012-12-01

    Hydroxocobalamin has been reported to interfere with the blood leak alarm on hemodialysis machines making it difficult to use this treatment modality after hydroxocobalamin infusion. The objective was to determine if this interference with hydroxocobalamin occurs across hemodialysis machines by different manufacturers. Additionally, we aimed to see if this represented a colorimetric interference alone or if it is the optical properties of hydroxocobalamin. Hydroxocobalamin was reconstituted per package insert. Food coloring was added to 0.9% saline to create the colors of the visual spectrum. Optical properties of absorbance and transmittance were measured. Hydroxocobalamin and the saline solutions were infused into the Fresenius 2008K™ and the Gambro Phoenix X36™ machines. Times were recorded from the start of the machine until the solution finished or the alarm triggered. When evaluating the Gambro Phoenix X36™ machine and dialysis circuit; the alarm did not trigger. In contrast, the blood leak alarm on the Fresenius 2008K™ machine was tripped by both the red solution and hydoxocobalamin infused per the package insert. The alarm stopped the machine between 128 and 132 seconds for the red solution and between 30 and 35 seconds with the hydroxocobalamin. Membranes of the circuits where the alarm tripped were examined and remained intact without blood. Results were validated on different machines with new circuits. Hydroxocobalamin infusion per package insert and the red saline solution prepared with Red Dye 40 both triggered the blood leak alarm and stopped the Fresenius 2008K™ machine. However, this was not true for the Gambro Phoenix X36™ machine as the alarm never triggered. The interference with the Fresenius 2008K™ appears colorimetric due to normal saline with Red Dye 40 triggering the alarm. We alert physicians to become familiar with the properties of individual dialysis machines prior to use of hydroxocobalamin. When facing difficulties with hemodialysis after the administration of hydroxocobalamin, consider attempting with a different manufactures machine or model if available or contact the manufacturer directly.

  7. Implications of resolved hypoxemia on the utility of desaturation alerts sent from an anesthesia decision support system to supervising anesthesiologists.

    PubMed

    Epstein, Richard H; Dexter, Franklin

    2012-10-01

    Hypoxemia (oxygen saturation <90%) lasting 2 or more minutes occurs in 6.8% of adult patients undergoing noncardiac anesthesia in operating room settings. Alarm management functionality can be added to decision support systems (DSS) to send text alerts about vital signs outside specified thresholds, using data in anesthesia information management systems. We considered enhancing our DSS to send hypoxemia alerts to the text pagers of supervising anesthesiologists. As part of a voluntary application for an investigative device exemption from our IRB to implement such functionality, we evaluated the maximum potential utility of such an alert system. Pulse oximetry values (Spo(2)) were extracted from our anesthesia information management systems for all cases performed in our main operating rooms and ambulatory surgical center between September 1, 2011, and February 4, 2012 (n = 16,870). Hypoxemic episodes (Spo(2) < 90%) were characterized as either (a) lasting one or more minutes or (b) lasting 2 or more minutes. A single simulated "alert" was modeled as having been sent at the timestamp of the first (a) or the second (b) hypoxemic value. The hypoxemic episode was considered resolved at 1, 3, or 5 minutes after the time of the alert if the Spo(2) value was no longer below the 90% threshold. Two-sided 99% conservative confidence limits were calculated for the percentage of unresolved alerts at the 3 evaluation intervals and compared with 70%, the lower limit of an acceptable true alarm rate for clinical utility. There was at least 1 hypoxemic episode lasting 1 minute or longer in 23% of cases, and at least 1 episode lasting 2 minutes or longer in 8% of cases. Only 7% (99% confidence interval [CI] 6% to 8%) of the 1-minute hypoxemic episodes were unresolved after 3 minutes, and only 8% (99% CI 6%to 9%) of 2-minute episodes after 5 minutes (both P < 10(-6) in comparison with 70% minimum reliability rate). Low utility should be expected for a DSS sending hypoxemia alerts to supervising anesthesiologists, because nearly all hypoxemic episodes will have been resolved before arrival of the anesthesiologist in the operating room. These results suggest that the principal research focus should be on developing more sophisticated alerts and processes within rooms for the anesthesia care provider to initiate treatment promptly, to interpret or correct artifacts, and to make it easier to call for assistance via a rapid communication system.

  8. FN-DFE: Fuzzy-Neural Data Fusion Engine for Enhanced State-Awareness of Resilient Hybrid Energy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ondrej Linda; Dumidu Wijayasekara; Milos Manic

    Resiliency and improved state-awareness of modern critical infrastructures, such as energy production and industrial systems, is becoming increasingly important. As control systems become increasingly complex, the number of inputs and outputs increase. Therefore, in order to maintain sufficient levels of state-awareness, a robust system state monitoring must be implemented that correctly identifies system behavior even when one or more sensors are faulty. Furthermore, as intelligent cyber adversaries become more capable, incorrect values may be fed to the operators. To address these needs, this paper proposes a Fuzzy-Neural Data Fusion Engine (FN-DFE) for resilient state-awareness of control systems. The designed FN-DFEmore » is composed of a three-layered system consisting of: 1) traditional threshold based alarms, 2) anomalous behavior detector using self-organizing fuzzy logic system, and 3) artificial neural network based system modeling and prediction. The improved control system state-awareness is achieved via fusing input data from multiple sources and combining them into robust anomaly indicators. In addition, the neural network based signal predictions are used to augment the resiliency of the system and provide coherent state-awareness despite temporary unavailability of sensory data. The proposed system was integrated and tested with a model of the Idaho National Laboratory’s (INL) hybrid energy system facility know as HYTEST. Experimental results demonstrate that the proposed FN-DFE provides timely plant performance monitoring and anomaly detection capabilities. It was shown that the system is capable of identifying intrusive behavior significantly earlier than conventional threshold based alarm systems.« less

  9. A new method of small target detection based on neural network

    NASA Astrophysics Data System (ADS)

    Hu, Jing; Hu, Yongli; Lu, Xinxin

    2018-02-01

    The detection and tracking of moving dim target in infrared image have been an research hotspot for many years. The target in each frame of images only occupies several pixels without any shape and structure information. Moreover, infrared small target is often submerged in complicated background with low signal-to-clutter ratio, making the detection very difficult. Different backgrounds exhibit different statistical properties, making it becomes extremely complex to detect the target. If the threshold segmentation is not reasonable, there may be more noise points in the final detection, which is unfavorable for the detection of the trajectory of the target. Single-frame target detection may not be able to obtain the desired target and cause high false alarm rate. We believe the combination of suspicious target detection spatially in each frame and temporal association for target tracking will increase reliability of tracking dim target. The detection of dim target is mainly divided into two parts, In the first part, we adopt bilateral filtering method in background suppression, after the threshold segmentation, the suspicious target in each frame are extracted, then we use LSTM(long short term memory) neural network to predict coordinates of target of the next frame. It is a brand-new method base on the movement characteristic of the target in sequence images which could respond to the changes in the relationship between past and future values of the values. Simulation results demonstrate proposed algorithm can effectively predict the trajectory of the moving small target and work efficiently and robustly with low false alarm.

  10. Applying Binary Forecasting Approaches to Induced Seismicity in the Western Canada Sedimentary Basin

    NASA Astrophysics Data System (ADS)

    Kahue, R.; Shcherbakov, R.

    2016-12-01

    The Western Canada Sedimentary Basin has been chosen as a focus due to an increase in the recent observed seismicity there which is most likely linked to anthropogenic activities related to unconventional oil and gas exploration. Seismicity caused by these types of activities is called induced seismicity. The occurrence of moderate to larger induced earthquakes in areas where critical infrastructure is present can be potentially problematic. Here we use a binary forecast method to analyze past seismicity and well production data in order to quantify future areas of increased seismicity. This method splits the given region into spatial cells. The binary forecast method used here has been suggested in the past to retroactively forecast large earthquakes occurring globally in areas called alarm cells. An alarm cell, or alert zone, is a bin in which there is a higher likelihood for earthquakes to occur based on previous data. The first method utilizes the cumulative Benioff strain, based on earthquakes that had occurred in each bin above a given magnitude over a time interval called the training period. The second method utilizes the cumulative well production data within each bin. Earthquakes that occurred within an alert zone in the retrospective forecast period contribute to the hit rate, while alert zones that did not have an earthquake occur within them in the forecast period contribute to the false alarm rate. In the resulting analysis the hit rate and false alarm rate are determined after optimizing and modifying the initial parameters using the receiver operating characteristic diagram. It is found that when modifying the cell size and threshold magnitude parameters within various training periods, hit and false alarm rates are obtained for specific regions in Western Canada using both recent seismicity and cumulative well production data. Certain areas are thus shown to be more prone to potential larger earthquakes based on both datasets. This has implications for the potential link between oil and gas production and induced seismicity observed in the Western Canada Sedimentary Basin.

  11. Performance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.

    PubMed

    Nizami, Shermeen; Greenwood, Kim; Barrowman, Nick; Harrold, JoAnn

    2015-09-01

    This crossover observational study compares the data characteristics and performance of new-generation Nellcor OXIMAX and Masimo SET SmartPod pulse oximeter technologies. The study was conducted independent of either original equipment manufacturer (OEM) across eleven preterm infants in a Neonatal Intensive Care Unit (NICU). The SmartPods were integrated with Dräger Infinity Delta monitors. The Delta monitor measured the heart rate (HR) using an independent electrocardiogram sensor, and the two SmartPods collected arterial oxygen saturation (SpO2) and pulse rate (PR). All patient data were non-Gaussian. Nellcor PR showed a higher correlation with the HR as compared to Masimo PR. The statistically significant difference found in their median values (1% for SpO2, 1 bpm for PR) was deemed clinically insignificant. SpO2 alarms generated by both SmartPods were observed and categorized for performance evaluation. Results for sensitivity, positive predictive value, accuracy and false alarm rates were Nellcor (80.3, 50, 44.5, 50%) and Masimo (72.2, 48.2, 40.6, 51.8%) respectively. These metrics were not statistically significantly different between the two pulse oximeters. Despite claims by OEMs, both pulse oximeters exhibited high false alarm rates, with no statistically or clinically significant difference in performance. These findings have a direct impact on alarm fatigue in the NICU. Performance evaluation studies can also impact medical device purchase decisions made by hospital administrators.

  12. Installation of Computerized Procedure System and Advanced Alarm System in the Human Systems Simulation Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Blanc, Katya Lee; Spielman, Zachary Alexander; Rice, Brandon Charles

    2016-04-01

    This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.

  13. Myocardial infarction false alarm: initial electrocardiogram and cardiac enzymes.

    PubMed

    Gupta, Esha Das; Sakthiswary, Rajalingham

    2014-05-01

    The objectives of this study were to determine the incidence of a myocardial infarction "false alarm" and evaluate the efficacy of the initial electrocardiogram and cardiac enzymes in diagnosing myocardial infarction in Malaysia. We recruited patients who were admitted with suspected myocardial infarction from June to August 2008. The medical records of these patients were reviewed for the initial electrocardiogram, initial cardiac enzyme levels (creatinine kinase-MB and troponin T), and the final diagnosis upon discharge. The subjects were stratified into 2 groups: true myocardial infarction, and false alarm. 125 patients were enrolled in this study. Following admission and further evaluation, the diagnosis was revised from myocardial infarction to other medical conditions in 48 (38.4%) patients. The sensitivity and specificity of the initial ischemic electrocardiographic changes were 54.5% and 70.8%, respectively. Raised cardiac enzymes had a sensitivity of 44.3% and specificity of 95.8%. A significant proportion of patients in Malaysia are admitted with a false-alarm myocardial infarction. The efficacy of the electrocardiogram in diagnosing myocardial infarction in Malaysia was comparable to the findings of Western studies, but the cardiac enzymes had a much lower sensitivity.

  14. Textile sensors for stab and cut detection

    NASA Astrophysics Data System (ADS)

    Graßmann, C.; Obermann, M.; Lempa, E.; Bache, T.; Siegel, P. K.; Freyer, T.; Paschko, S.; Beyer, T.; Kirsche, M.; Schwarz-Pfeiffer, A.

    2017-10-01

    Manufacturers are aiming for more flexible and lightweight protective clothing to increase wearing comfort. A cardigan with a knitted stab-resistant inlay and an alarm system is presented. The stab-resistant inlay is based on a multilayer ultra-high molecular weight poly ethylene (UHMW-PE) fabric. Stab resistance was evaluated according to the standard of the Association of Test Laboratories for Bullet, Stab or Pike Resistant Materials and Construction Standard (VPAM 2011). Furthermore sensors for the detection of cuts and pressure were integrated. Both sensors can trigger alarms if the wearer is attacked. Normal pressure occurring through leaning on a wall or sitting is filtered out and does not trigger an alarm.

  15. Impact of Mandatory Carbon Monoxide Alarms: An Investigation of the Effects on Detection and Poisoning Rates in New York City

    PubMed Central

    Wheeler-Martin, Katherine; Soghoian, Sari; Manini, Alex F.; Marker, Elizabeth; Stajic, Marina; Prezant, David; Nelson, Lewis S.; Hoffman, Robert S.

    2015-01-01

    Objectives. We sought to evaluate the impact of New York City’s (NYC’s) 2004 carbon monoxide (CO) alarm legislation on CO incident detection and poisoning rates. Methods. We compared CO poisoning deaths, hospitalizations, exposures reported to Poison Control, and fire department investigations, before and after the law for 2000 to 2010. Use of CO alarms was assessed in the 2009 NYC Community Health Survey. Results. Investigations that found indoor CO levels greater than 9 parts per million increased nearly 7-fold after the law (P < .001). There were nonsignificant decreases in unintentional, nonfire-related CO poisoning hospitalization rates (P = .114) and death rates (P = .216). After we controlled for ambient temperature, the law’s effect on hospitalizations remained nonsignificantly protective (incidence rate ratio = 0.747; 95% confidence interval = 0.520, 1.074). By 2009, 83% of NYC residents reported having CO alarms; only 54% also recently tested or replaced their batteries. Conclusions. Mandating CO alarms significantly increased the detection of potentially hazardous CO levels in NYC homes. Small numbers and detection bias might have limited the discovery of significant decreases in poisoning outcomes. Investigation of individual poisoning circumstances since the law might elucidate remaining gaps in awareness and proper use of CO alarms. PMID:26066948

  16. Benefit of an electronic medical record-based alarm in the optimization of stress ulcer prophylaxis.

    PubMed

    Saad, Emanuel José; Bedini, Marianela; Becerra, Ana Florencia; Martini, Gustavo Daniel; Gonzalez, Jacqueline Griselda; Bolomo, Andrea; Castellani, Luciana; Quiroga, Silvana; Morales, Cristian; Leathers, James; Balderramo, Domingo; Albertini, Ricardo Arturo

    2018-06-09

    The use of stress ulcer prophylaxis (SUP) has risen in recent years, even in patients without a clear indication for therapy. To evaluate the efficacy of an electronic medical record (EMR)-based alarm to improve appropriate SUP use in hospitalized patients. We conducted an uncontrolled before-after study comparing SUP prescription in intensive care unit (ICU) patients and non-ICU patients, before and after the implementation of an EMR-based alarm that provided the correct indications for SUP. 1627 patients in the pre-intervention and 1513 patients in the post-intervention cohorts were included. The EMR-based alarm improved appropriate (49.6% vs. 66.6%, p<0.001) and reduced inappropriate SUP use (50.4% vs. 33.3%, p<0.001) in ICU patients only. These differences were related to the optimization of SUP in low risk patients. There was no difference in overt gastrointestinal bleeding between the two cohorts. Unjustified costs related to SUP were reduced by a third after EMR-based alarm use. The use of an EMR-based alarm improved appropriate and reduced inappropriate use of SUP in ICU patients. This benefit was limited to optimization in low risk patients and associated with a decrease in SUP costs. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  17. Texture orientation-based algorithm for detecting infrared maritime targets.

    PubMed

    Wang, Bin; Dong, Lili; Zhao, Ming; Wu, Houde; Xu, Wenhai

    2015-05-20

    Infrared maritime target detection is a key technology for maritime target searching systems. However, in infrared maritime images (IMIs) taken under complicated sea conditions, background clutters, such as ocean waves, clouds or sea fog, usually have high intensity that can easily overwhelm the brightness of real targets, which is difficult for traditional target detection algorithms to deal with. To mitigate this problem, this paper proposes a novel target detection algorithm based on texture orientation. This algorithm first extracts suspected targets by analyzing the intersubband correlation between horizontal and vertical wavelet subbands of the original IMI on the first scale. Then the self-adaptive wavelet threshold denoising and local singularity analysis of the original IMI is combined to remove false alarms further. Experiments show that compared with traditional algorithms, this algorithm can suppress background clutter much better and realize better single-frame detection for infrared maritime targets. Besides, in order to guarantee accurate target extraction further, the pipeline-filtering algorithm is adopted to eliminate residual false alarms. The high practical value and applicability of this proposed strategy is backed strongly by experimental data acquired under different environmental conditions.

  18. Predicting Fog in the Nocturnal Boundary Layer

    NASA Astrophysics Data System (ADS)

    Izett, Jonathan; van de Wiel, Bas; Baas, Peter; van der Linden, Steven; van Hooft, Antoon; Bosveld, Fred

    2017-04-01

    Fog is a global phenomenon that presents a hazard to navigation and human safety, resulting in significant economic impacts for air and shipping industries as well as causing numerous road traffic accidents. Accurate prediction of fog events, however, remains elusive both in terms of timing and occurrence itself. Statistical methods based on set threshold criteria for key variables such as wind speed have been developed, but high rates of correct prediction of fog events still lead to similarly high "false alarms" when the conditions appear favourable, but no fog forms. Using data from the CESAR meteorological observatory in the Netherlands, we analyze specific cases and perform statistical analyses of event climatology, in order to identify the necessary conditions for correct prediction of fog. We also identify potential "missing ingredients" in current analysis that could help to reduce the number of false alarms. New variables considered include the indicators of boundary layer stability, as well as the presence of aerosols conducive to droplet formation. The poster presents initial findings of new research as well as plans for continued research.

  19. Novel threshold pressure sensors based on nonlinear dynamics of MEMS resonators

    NASA Astrophysics Data System (ADS)

    Hasan, Mohammad H.; Alsaleem, Fadi M.; Ouakad, Hassen M.

    2018-06-01

    Triggering an alarm in a car for low air-pressure in the tire or tripping an HVAC compressor if the refrigerant pressure is lower than a threshold value are examples for applications where measuring the amount of pressure is not as important as determining if the pressure has exceeded a threshold value for an action to occur. Unfortunately, current technology still relies on analog pressure sensors to perform this functionality by adding a complex interface (extra circuitry, controllers, and/or decision units). In this paper, we demonstrate two new smart tunable-threshold pressure switch concepts that can reduce the complexity of a threshold pressure sensor. The first concept is based on the nonlinear subharmonic resonance of a straight double cantilever microbeam with a proof mass and the other concept is based on the snap-through bi-stability of a clamped-clamped MEMS shallow arch. In both designs, the sensor operation concept is simple. Any actuation performed at a certain pressure lower than a threshold value will activate a nonlinear dynamic behavior (subharmonic resonance or snap-through bi-stability) yielding a large output that would be interpreted as a logic value of ONE, or ON. Once the pressure exceeds the threshold value, the nonlinear response ceases to exist, yielding a small output that would be interpreted as a logic value of ZERO, or OFF. A lumped, single degree of freedom model for the double cantilever beam, that is validated using experimental data, and a continuous beam model for the arch beam, are used to simulate the operation range of the proposed sensors by identifying the relationship between the excitation signal and the critical cut-off pressure.

  20. A quantitative method for optimized placement of continuous air monitors.

    PubMed

    Whicker, Jeffrey J; Rodgers, John C; Moxley, John S

    2003-11-01

    Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.

  1. Type testing of the Siemens Plessey electronic personal dosemeter.

    PubMed

    Hirning, C R; Yuen, P S

    1995-07-01

    This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.

  2. Predicting electrocardiogram and arterial blood pressure waveforms with different Echo State Network architectures.

    PubMed

    Fong, Allan; Mittu, Ranjeev; Ratwani, Raj; Reggia, James

    2014-01-01

    Alarm fatigue caused by false alarms and alerts is an extremely important issue for the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the staff and hospital systems better classify a patient's waveforms and subsequent alarms. This paper explores the use of Echo State Networks, a specific type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network architectures are designed and evaluated. The results show the utility of these echo state networks, particularly ones with larger integrated reservoirs, for predicting electrocardiogram waveforms and the adaptability of such models across individuals. The work presented here offers a unique approach for understanding and predicting a patient's waveforms in order to potentially improve alarm generation. We conclude with a brief discussion of future extensions of this research.

  3. User acceptance of intelligent avionics: A study of automatic-aided target recognition

    NASA Technical Reports Server (NTRS)

    Becker, Curtis A.; Hayes, Brian C.; Gorman, Patrick C.

    1991-01-01

    User acceptance of new support systems typically was evaluated after the systems were specified, designed, and built. The current study attempts to assess user acceptance of an Automatic-Aided Target Recognition (ATR) system using an emulation of such a proposed system. The detection accuracy and false alarm level of the ATR system were varied systematically, and subjects rated the tactical value of systems exhibiting different performance levels. Both detection accuracy and false alarm level affected the subjects' ratings. The data from two experiments suggest a cut-off point in ATR performance below which the subjects saw little tactical value in the system. An ATR system seems to have obvious tactical value only if it functions at a correct detection rate of 0.7 or better with a false alarm level of 0.167 false alarms per square degree or fewer.

  4. An analysis of an early-warning system to reduce abortions in dairy cattle in Denmark incorporating both financial and epidemiologic aspects.

    PubMed

    Carpenter, Tim E; Chrièl, Mariann; Greiner, Matthias

    2007-01-16

    Emergency preparedness relies on the ability to detect patterns in rare incidents in an early stage of an outbreak in order to implement relevant actions. Early warning of an abortion storm as a result of infection with a notifiable disease, e.g. brucellosis, bovine viral diarrhea (BVD) or infectious bovine rhinotracheitis (IBR), is a significant surveillance tool. This study used data from 507 large Danish dairy herds. A modified two-stage method for detecting an unusual increase in the abortion incidence was applied to the data. An alarm was considered true if an abortion were detected in the month following the alarm month, otherwise false. The total number of abortions that could potentially be avoided if effective action were taken ranged from 769 (22.9%) to 10 (0.3%), as the number of abortions required to set the alarm increased from 1 to 6. The vast majority of abortions could, however, not be predicted, much less prevented, given this early-warning system. The false to true alarm ratio was reduced when the number of abortions that set the alarm increased. The financial scenarios evaluated demonstrated that the value of an abortion, the cost of responding to an alarm and the efficiency of the actions are important for decision making when reporting an alarm. The presented model can readily be extended to other disease problems and multiple-time periods.

  5. "Alarm-corrected" ergonomic armrest use could improve learning curves of novices on robotic simulator.

    PubMed

    Yang, Kun; Perez, Manuela; Hossu, Gabriela; Hubert, Nicolas; Perrenot, Cyril; Hubert, Jacques

    2017-01-01

    In robotic surgery, the professional ergonomic habit of using an armrest reduces operator fatigue and increases the precision of motion. We designed and validated a pressure surveillance system (PSS) based on force sensors to investigate armrest use. The objective was to evaluate whether adding an alarm to the PSS system could shorten ergonomic training and improve performance. Twenty robot and simulator-naïve participants were recruited and randomized in two groups (A and B). The PSS was installed on a robotic simulator, the dV-Trainer, to detect contact with the armrest. The Group A members completed three tasks on the dV-Trainer without the alarm, making 15 attempts at each task. The Group B members practiced the first two tasks with the alarm and then completed the final tasks without the alarm. The simulator provided an overall score reflecting the trainees' performance. We used the new concept of an "armrest load" score to describe the ergonomic habit of using the armrest. Group B had a significantly higher performance score (p < 0.001) and armrest load score (p < 0.001) than Group A from the fifth attempt of the first task to the end of the experiment. Based on the conditioned reflex effect, the alarm associated with the PSS rectified ergonomic errors and accelerated professional ergonomic habit acquisition. The combination of the PSS and alarm is effective in significantly shortening the learning curve in the robotic training process.

  6. A Novel Enuresis Alarm for Toilet Training Students with Intellectual Disability: An Initial Evaluation in a School Setting

    ERIC Educational Resources Information Center

    Mruzek, Daniel W.; McAleavey, Stephen; Engel, Suzanne; Smith, Tristram

    2016-01-01

    In this study, a novel enuresis alarm device using a miniaturized radio frequency module and disposable sensors made with inexpensive conductive ink was used to teach toilet use for urination with three participants with severe intellectual disability (two males and one female; aged 7-15 years) in a private special education school setting. At…

  7. Hypoglycemia early alarm systems based on recursive autoregressive partial least squares models.

    PubMed

    Bayrak, Elif Seyma; Turksoy, Kamuran; Cinar, Ali; Quinn, Lauretta; Littlejohn, Elizabeth; Rollins, Derrick

    2013-01-01

    Hypoglycemia caused by intensive insulin therapy is a major challenge for artificial pancreas systems. Early detection and prevention of potential hypoglycemia are essential for the acceptance of fully automated artificial pancreas systems. Many of the proposed alarm systems are based on interpretation of recent values or trends in glucose values. In the present study, subject-specific linear models are introduced to capture glucose variations and predict future blood glucose concentrations. These models can be used in early alarm systems of potential hypoglycemia. A recursive autoregressive partial least squares (RARPLS) algorithm is used to model the continuous glucose monitoring sensor data and predict future glucose concentrations for use in hypoglycemia alarm systems. The partial least squares models constructed are updated recursively at each sampling step with a moving window. An early hypoglycemia alarm algorithm using these models is proposed and evaluated. Glucose prediction models based on real-time filtered data has a root mean squared error of 7.79 and a sum of squares of glucose prediction error of 7.35% for six-step-ahead (30 min) glucose predictions. The early alarm systems based on RARPLS shows good performance. A sensitivity of 86% and a false alarm rate of 0.42 false positive/day are obtained for the early alarm system based on six-step-ahead predicted glucose values with an average early detection time of 25.25 min. The RARPLS models developed provide satisfactory glucose prediction with relatively smaller error than other proposed algorithms and are good candidates to forecast and warn about potential hypoglycemia unless preventive action is taken far in advance. © 2012 Diabetes Technology Society.

  8. Hypoglycemia Early Alarm Systems Based on Recursive Autoregressive Partial Least Squares Models

    PubMed Central

    Bayrak, Elif Seyma; Turksoy, Kamuran; Cinar, Ali; Quinn, Lauretta; Littlejohn, Elizabeth; Rollins, Derrick

    2013-01-01

    Background Hypoglycemia caused by intensive insulin therapy is a major challenge for artificial pancreas systems. Early detection and prevention of potential hypoglycemia are essential for the acceptance of fully automated artificial pancreas systems. Many of the proposed alarm systems are based on interpretation of recent values or trends in glucose values. In the present study, subject-specific linear models are introduced to capture glucose variations and predict future blood glucose concentrations. These models can be used in early alarm systems of potential hypoglycemia. Methods A recursive autoregressive partial least squares (RARPLS) algorithm is used to model the continuous glucose monitoring sensor data and predict future glucose concentrations for use in hypoglycemia alarm systems. The partial least squares models constructed are updated recursively at each sampling step with a moving window. An early hypoglycemia alarm algorithm using these models is proposed and evaluated. Results Glucose prediction models based on real-time filtered data has a root mean squared error of 7.79 and a sum of squares of glucose prediction error of 7.35% for six-step-ahead (30 min) glucose predictions. The early alarm systems based on RARPLS shows good performance. A sensitivity of 86% and a false alarm rate of 0.42 false positive/day are obtained for the early alarm system based on six-step-ahead predicted glucose values with an average early detection time of 25.25 min. Conclusions The RARPLS models developed provide satisfactory glucose prediction with relatively smaller error than other proposed algorithms and are good candidates to forecast and warn about potential hypoglycemia unless preventive action is taken far in advance. PMID:23439179

  9. Rapid and Reliable Damage Proxy Map from InSAR Coherence

    NASA Technical Reports Server (NTRS)

    Yun, Sang-Ho; Fielding, Eric; Simons, Mark; Agram, Piyush; Rosen, Paul; Owen, Susan; Webb, Frank

    2012-01-01

    Future radar satellites will visit SoCal within a day after a disaster event. Data acquisition latency in 2015-2020 is 8 to approx. 15 hours. Data transfer latency that often involves human/agency intervention far exceeds the data acquisition latency. Need interagency cooperation to establish automatic pipeline for data transfer. The algorithm is tested with ALOS PALSAR data of Pasadena, California. Quantitative quality assessment is being pursued: Meeting with Pasadena City Hall computer engineers for a complete list of demolition/construction project 1. Estimate the probability of detection and probability of false alarm 2. Estimate the optimal threshold value.

  10. Safety vs. privacy: elderly persons' experiences of a mobile safety alarm.

    PubMed

    Melander-Wikman, Anita; Fältholm, Ylva; Gard, Gunvor

    2008-07-01

    The demographic development indicates an increased elderly population in Sweden in the future. One of the greatest challenges for a society with an ageing population is to provide high-quality health and social care. New information and communication technology and services can be used to further improve health care. To enable elderly persons to stay at home as long as possible, various kinds of technology, such as safety alarms, are used at home. The aim of this study was to describe the experiences of elderly persons through testing a mobile safety alarm and their reasoning about safety, privacy and mobility. The mobile safety alarm tested was a prototype in development. Five elderly persons with functional limitations and four healthy elderly persons from a pensioner's organisation tested the alarm. The mobile alarm with a drop sensor and a positioning device was tested for 6 weeks. This intervention was evaluated with qualitative interviews, and analysed with latent content analysis. The result showed four main categories: feeling safe, being positioned and supervised, being mobile, and reflecting on new technology. From these categories, the overarching category 'Safety and mobility are more important than privacy' emerged. The mobile safety alarm was perceived to offer an increased opportunity for mobility in terms of being more active and as an aid for self-determination. The fact that the informants were located by means of the positioning device was not experienced as violating privacy as long as they could decide how to use the alarm. It was concluded that this mobile safety alarm was experienced as a tool to be active and mobile. As a way to keep self-determination and empowerment, the individual has to make a 'cost-benefit' analysis where privacy is sacrificed to the benefit of mobility and safety. The participants were actively contributing to the development process.

  11. Carbon monoxide poisoning at motels, hotels, and resorts.

    PubMed

    Weaver, Lindell K; Deru, Kayla

    2007-07-01

    Each year, more than 200 people in the United States die from carbon monoxide (CO) poisoning. Poisoning has occurred at motels, hotels, and resorts. Congressional mandate requires smoke alarms in all guest rooms; however, smoke alarms do not detect CO. Data on patients poisoned at hotels, motels, and resorts were evaluated at a hyperbaric medicine service. In 2005, legal databases and online news databanks were searched to discover additional incidents. Only victims evaluated in hospitals or declared dead at the scene were included. Cases of intentional poisoning and poisoning from fires were excluded. Between 1989 and 2004, 68 incidents of CO poisoning occurring at hotels, motels, and resorts were identified, resulting in 772 accidentally poisoned: 711 guests, 41 employees or owners, and 20 rescue personnel. Of those poisoned, 27 died, 66 had confirmed sequelae, and 6 had sequelae resulting in a jury verdict. Lodging-operated, faulty room heating caused 45 incidents, pool/spa boilers 16, CO entrained from outdoors 5, and unreported sources caused 2 incidents. Public verdicts have averaged $4.8 million per incident (range, $1 million to $17.5 million). Poisoning occurred at hotels of all classes. Despite these incidents, most properties did not install CO alarms, and requirements for CO alarms at hotels, motels, and resorts are rare. Guests of motels, hotels, and resorts remain at risk for injury or death from CO poisoning. Measures to prevent CO poisoning of guests and employees of the lodging industry should be evaluated.

  12. The ecology and evolution of avian alarm call signaling systems

    NASA Astrophysics Data System (ADS)

    Billings, Alexis Chandon

    Communication is often set up as a simple dyadic exchange between one sender and one receiver. However, in reality, signaling systems have evolved and are used with many forms and types of information bombarding multiple senders, who in turn send multiple signals of different modalities, through various environmental spaces, finally reaching multiple receivers. In order to understand both the ecology and evolution of a signaling system, we must examine all the facets of the signaling system. My dissertation focused on the alarm call signaling system in birds. Alarm calls are acoustic signals given in response to danger or predators. My first two chapters examine how information about predators alters alarm calls. In chapter one I found that chickadees make distinctions between predators of different hunting strategies and appear to encode information about predators differently if they are heard instead of seen. In my second chapter, I test these findings more robustly in a non-model bird, the Steller's jay. I again found that predator species matters, but that how Steller's jays respond if they saw or heard the predator depends on the predator species. In my third chapter, I tested how habitat has influenced the evolution of mobbing call acoustic structure. I found that habitat is not a major contributor to the variation in acoustic structure seen across species and that other selective pressures such as body size may be more important. In my fourth chapter I present a new framework to understand the evolution of multimodal communication across species. I identify a unique constraint, the need for overlapping sensory systems, thresholds and cognitive abilities between sender and receiver in order for different forms of interspecific communication to evolve. Taken together, these chapters attempt to understand a signaling system from both an ecological and evolutionary perspective by examining each piece of the communication scheme.

  13. Feasibility of the capnogram to monitor ventilation rate during cardiopulmonary resuscitation.

    PubMed

    Aramendi, Elisabete; Elola, Andoni; Alonso, Erik; Irusta, Unai; Daya, Mohamud; Russell, James K; Hubner, Pia; Sterz, Fritz

    2017-01-01

    The rates of chest compressions (CCs) and ventilations are both important metrics to monitor the quality of cardiopulmonary resuscitation (CPR). Capnography permits monitoring ventilation, but the CCs provided during CPR corrupt the capnogram and compromise the accuracy of automatic ventilation detectors. The aim of this study was to evaluate the feasibility of an automatic algorithm based on the capnogram to detect ventilations and provide feedback on ventilation rate during CPR, specifically addressing intervals where CCs are delivered. The dataset used to develop and test the algorithm contained in-hospital and out-of-hospital cardiac arrest episodes. The method relies on adaptive thresholding to detect ventilations in the first derivative of the capnogram. The performance of the detector was reported in terms of sensitivity (SE) and Positive Predictive Value (PPV). The overall performance was reported in terms of the rate error and errors in the hyperventilation alarms. Results were given separately for the intervals with CCs. A total of 83 episodes were considered, resulting in 4880min and 46,740 ventilations (8741 during CCs). The method showed an overall SE/PPV above 99% and 97% respectively, even in intervals with CCs. The error for the ventilation rate was below 1.8min -1 in any group, and >99% of the ventilation alarms were correctly detected. A method to provide accurate feedback on ventilation rate using only the capnogram is proposed. Its accuracy was proven even in intervals where canpography signal was severely corrupted by CCs. This algorithm could be integrated into monitor/defibrillators to provide reliable feedback on ventilation rate during CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Perceptual evaluation of visual alerts in surveillance videos

    NASA Astrophysics Data System (ADS)

    Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun

    2015-03-01

    Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.

  15. Identifying humanitarian crises in population surveillance field sites: simple procedures and ethical imperatives.

    PubMed

    Fottrell, E; Byass, P

    2009-02-01

    Effective early warning systems of humanitarian crises may help to avert substantial increases in mortality and morbidity, and prevent major population movements. The Butajira Rural Health Programme (BRHP) in Ethiopia has maintained a programme of epidemiological surveillance since 1987. Inspection of the BRHP data revealed large peaks of mortality in 1998 and 1999, well in excess of the normally observed year-to-year variation. Further investigation and enquiry revealed that these peaks related to a measles epidemic, and a serious episode of drought and consequent food insecurity that went undetected by the BRHP. This paper applies international humanitarian crisis threshold definitions to the BRHP data in an attempt to identify suitable mortality thresholds that may be used for the prospective detection of humanitarian crises in population surveillance sites in developing countries. Empirical investigation using secondary analysis of longitudinal population-based cohort data. The daily, weekly and monthly thresholds for crises in Butajira were applied to mortality data for the 5-year period incorporating the crisis periods of 1998-1999. Days, weeks and months in which mortality exceeded each threshold level were identified. Each threshold level was assessed in terms of prospectively identifying the true crisis periods in a timely manner whilst avoiding false alarms. The daily threshold definition is too sensitive to accurately detect impending or real crises in the population surveillance setting of the BRHP. However, the weekly threshold level is useful in identifying important increases in mortality in a timely manner without the excessive sensitivity of the daily threshold. The weekly threshold level detects the crisis periods approximately 2 weeks before the monthly threshold level. Mortality measures are highly specific indicators of the health status of populations, and simple procedures can be used to apply international crisis threshold definitions in population surveillance settings for the prospective detection of important changes in mortality rate. Standards for the timely use of surveillance data and ethical responsibilities of those responsible for the data should be made explicit to improve the public health functioning of current sentinel surveillance methodologies.

  16. Changes in smoke alarm coverage following two fire department home visiting programs: what predicts success?

    PubMed

    Gielen, Andrea C; Perry, Elise C; Shields, Wendy C; McDonald, Eileen; Frattaroli, Shannon; Jones, Vanya

    2014-12-01

    Door-to-door canvassing and installation of smoke alarms have been found to be effective at increasing the number of homes protected. This analysis reports on how smoke alarm coverage changes six months after a home visiting program in a large urban sample, and how this change varies by characteristics of the residents and characteristics of the services delivered during the home visit. Fire department Standard and Enhanced home visiting programs were compared. During the home visit, fire fighters installed lithium battery smoke alarms. Residents in the Enhanced program received tailored education about fire safety. Six months after the home visit, participating residences were visited to complete a follow-up survey and to have the installed alarms checked. 81% of the 672 homes that had a working smoke alarm on every level of the home at the end of the home visit remained safe at follow-up, and 87% of the residents found the home visit was very useful, and these rates did not differ between the Enhanced and Standard programs. The degree to which firefighters delivered their services varied, although households in which the resident's engagement with the fire department team was rated as excellent were 3.96 times as likely to be safe at follow-up compared to those with poor or fair resident engagement (p=0.03). There is a need to better understand how to maximize the time spent with residents during smoke alarm home visiting programs. This study helps with the development of methods needed for implementing and evaluating such programs in real-world settings.

  17. Electroantennogram and behavioral responses of the imported fire ant, Solenopsis invicta Buren, to an alarm pheromone component and its analogues.

    PubMed

    Guan, Di; Lu, Yong-Yue; Liao, Xiao-Lan; Wang, Lei; Chen, Li

    2014-12-10

    A characteristic behavior in ants is to move rapidly to emission sources of alarm pheromones. The addition of ant alarm pheromones to bait is expected to enhance its attractiveness. To search for candidate compounds for bait enhancement in fire ant control, 13 related alkylpyrazine analogues in addition to synthetic alarm pheromone component were evaluated for electroantennogram (EAG) and behavioral activities in Solenopsis invicta. Most compounds elicited dose-dependent EAG and behavioral responses. There exists a correlation between the EAG and behavioral responses. Among the 14 tested alkylpyrazines, three compounds, 2-ethyl-3,6(5)-dimethyl pyrazine (1), 2,3,5-trimethylpyrazine (7), and 2,3-diethyl-5-methylpyrazine (12), elicited significant alarm responses at a dose range of 0.1-1000 ng. Further bait discovery bioassay with the three most active alkylpyrazines demonstrated that food bait accompanied by sample-treated filter paper disk attracted significantly more fire ant workers in the first 15 min period. EAG and behavioral bioassays with pure pheromone isomers accumulated by semi-preparative high-performance liquid chromatography demonstrated that 2-ethyl-3,6-dimethylpyrazine was significantly more active than 2-ethyl-3,5-dimethylpyrazine.

  18. Novel Hierarchical Fall Detection Algorithm Using a Multiphase Fall Model.

    PubMed

    Hsieh, Chia-Yeh; Liu, Kai-Chun; Huang, Chih-Ning; Chu, Woei-Chyn; Chan, Chia-Tai

    2017-02-08

    Falls are the primary cause of accidents for the elderly in the living environment. Reducing hazards in the living environment and performing exercises for training balance and muscles are the common strategies for fall prevention. However, falls cannot be avoided completely; fall detection provides an alarm that can decrease injuries or death caused by the lack of rescue. The automatic fall detection system has opportunities to provide real-time emergency alarms for improving the safety and quality of home healthcare services. Two common technical challenges are also tackled in order to provide a reliable fall detection algorithm, including variability and ambiguity. We propose a novel hierarchical fall detection algorithm involving threshold-based and knowledge-based approaches to detect a fall event. The threshold-based approach efficiently supports the detection and identification of fall events from continuous sensor data. A multiphase fall model is utilized, including free fall, impact, and rest phases for the knowledge-based approach, which identifies fall events and has the potential to deal with the aforementioned technical challenges of a fall detection system. Seven kinds of falls and seven types of daily activities arranged in an experiment are used to explore the performance of the proposed fall detection algorithm. The overall performances of the sensitivity, specificity, precision, and accuracy using a knowledge-based algorithm are 99.79%, 98.74%, 99.05% and 99.33%, respectively. The results show that the proposed novel hierarchical fall detection algorithm can cope with the variability and ambiguity of the technical challenges and fulfill the reliability, adaptability, and flexibility requirements of an automatic fall detection system with respect to the individual differences.

  19. Novel Hierarchical Fall Detection Algorithm Using a Multiphase Fall Model

    PubMed Central

    Hsieh, Chia-Yeh; Liu, Kai-Chun; Huang, Chih-Ning; Chu, Woei-Chyn; Chan, Chia-Tai

    2017-01-01

    Falls are the primary cause of accidents for the elderly in the living environment. Reducing hazards in the living environment and performing exercises for training balance and muscles are the common strategies for fall prevention. However, falls cannot be avoided completely; fall detection provides an alarm that can decrease injuries or death caused by the lack of rescue. The automatic fall detection system has opportunities to provide real-time emergency alarms for improving the safety and quality of home healthcare services. Two common technical challenges are also tackled in order to provide a reliable fall detection algorithm, including variability and ambiguity. We propose a novel hierarchical fall detection algorithm involving threshold-based and knowledge-based approaches to detect a fall event. The threshold-based approach efficiently supports the detection and identification of fall events from continuous sensor data. A multiphase fall model is utilized, including free fall, impact, and rest phases for the knowledge-based approach, which identifies fall events and has the potential to deal with the aforementioned technical challenges of a fall detection system. Seven kinds of falls and seven types of daily activities arranged in an experiment are used to explore the performance of the proposed fall detection algorithm. The overall performances of the sensitivity, specificity, precision, and accuracy using a knowledge-based algorithm are 99.79%, 98.74%, 99.05% and 99.33%, respectively. The results show that the proposed novel hierarchical fall detection algorithm can cope with the variability and ambiguity of the technical challenges and fulfill the reliability, adaptability, and flexibility requirements of an automatic fall detection system with respect to the individual differences. PMID:28208694

  20. Alarm Variables for Dengue Outbreaks: A Multi-Centre Study in Asia and Latin America

    PubMed Central

    Bowman, Leigh R.; Tejeda, Gustavo S.; Coelho, Giovanini E.; Sulaiman, Lokman H.; Gill, Balvinder S.; McCall, Philip J.; Olliaro, Piero L.; Ranzinger, Silvia R.; Quang, Luong C.; Ramm, Ronald S.; Kroeger, Axel; Petzold, Max G.

    2016-01-01

    Background Worldwide, dengue is an unrelenting economic and health burden. Dengue outbreaks have become increasingly common, which place great strain on health infrastructure and services. Early warning models could allow health systems and vector control programmes to respond more cost-effectively and efficiently. Methodology/Principal Findings The Shewhart method and Endemic Channel were used to identify alarm variables that may predict dengue outbreaks. Five country datasets were compiled by epidemiological week over the years 2007–2013. These data were split between the years 2007–2011 (historic period) and 2012–2013 (evaluation period). Associations between alarm/ outbreak variables were analysed using logistic regression during the historic period while alarm and outbreak signals were captured during the evaluation period. These signals were combined to form alarm/ outbreak periods, where 2 signals were equal to 1 period. Alarm periods were quantified and used to predict subsequent outbreak periods. Across Mexico and Dominican Republic, an increase in probable cases predicted outbreaks of hospitalised cases with sensitivities and positive predictive values (PPV) of 93%/ 83% and 97%/ 86% respectively, at a lag of 1–12 weeks. An increase in mean temperature ably predicted outbreaks of hospitalised cases in Mexico and Brazil, with sensitivities and PPVs of 79%/ 73% and 81%/ 46% respectively, also at a lag of 1–12 weeks. Mean age was predictive of hospitalised cases at sensitivities and PPVs of 72%/ 74% and 96%/ 45% in Mexico and Malaysia respectively, at a lag of 4–16 weeks. Conclusions/Significance An increase in probable cases was predictive of outbreaks, while meteorological variables, particularly mean temperature, demonstrated predictive potential in some countries, but not all. While it is difficult to define uniform variables applicable in every country context, the use of probable cases and meteorological variables in tailored early warning systems could be used to highlight the occurrence of dengue outbreaks or indicate increased risk of dengue transmission. PMID:27348752

  1. Economic evaluation of smoke alarm distribution methods in Baltimore, Maryland.

    PubMed

    Diamond-Smith, Nadia; Bishai, David; Perry, Elise; Shields, Wendy; Gielen, Andrea

    2014-08-01

    This paper analyses costs and potential lives saved from a door-to-door smoke alarm distribution programme using data from a programme run by the Baltimore City Fire Department in 2010-2011. We evaluate the impact of a standard home visit programme and an enhanced home visit programme that includes having community health workers provide advance notice, promote the programme, and accompany fire department personnel on the day of the home visit, compared with each other and with an option of not having a home visit programme (control). Study data show that the home visit programme increased by 10% the number of homes that went from having no working alarm to having any working alarm, and the enhanced programme added an additional 1% to the number of homes protected. We use published reports on the relative risk of death in homes with and without a working smoke alarm to show that the standard programme would save an additional 0.24 lives per 10,000 homes over 10 years, compared with control areas and the enhanced home visit programme saved an additional 0.07 lives compared with the standard programme. The incremental cost of each life saved for the standard programme compared with control was $28,252 per death averted and $284,501per additional death averted for the enhanced compared with the standard. Following the US guidelines for the value of a life, both programmes are cost effective, however, the standard programme may offer a better value in terms of dollars per death averted. The study also highlights the need for better data on the benefits of current smoke alarm recommendations and their impact on injury, death and property damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Qishi; Zhu, Mengxia; Rao, Nageswara S

    We propose an intelligent decision support system based on sensor and computer networks that incorporates various component techniques for sensor deployment, data routing, distributed computing, and information fusion. The integrated system is deployed in a distributed environment composed of both wireless sensor networks for data collection and wired computer networks for data processing in support of homeland security defense. We present the system framework and formulate the analytical problems and develop approximate or exact solutions for the subtasks: (i) sensor deployment strategy based on a two-dimensional genetic algorithm to achieve maximum coverage with cost constraints; (ii) data routing scheme tomore » achieve maximum signal strength with minimum path loss, high energy efficiency, and effective fault tolerance; (iii) network mapping method to assign computing modules to network nodes for high-performance distributed data processing; and (iv) binary decision fusion rule that derive threshold bounds to improve system hit rate and false alarm rate. These component solutions are implemented and evaluated through either experiments or simulations in various application scenarios. The extensive results demonstrate that these component solutions imbue the integrated system with the desirable and useful quality of intelligence in decision making.« less

  3. Smartphone application for emergency signal detection.

    PubMed

    Figueiredo, Isabel N; Leal, Carlos; Pinto, Luís; Bolito, Jason; Lemos, André

    2016-09-01

    Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). This innovative and novel system enables users to simply hit their devices in order to send an alarm signal to an emergency service. This application is a complete and autonomous emergency system, and can provide an economic, reliable, and unobtrusive method for elderly monitoring or safety protection. Moreover, the simple and fast activation of KTP makes it a viable and potentially superior alternative to traditional ambient assisted living emergency calls. Furthermore, KTP can be further extended to the general population as well and not just be limited for elderly persons. The proposed method is a threshold-based algorithm and is designed to require a low battery power consumption. The evaluation of the performance of the algorithm in collected data indicates that both sensitivity and specificity are above 90%. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Pre-slaughter cattle welfare indicators for use in commercial abattoirs with voluntary monitoring systems: A systematic review.

    PubMed

    Losada-Espinosa, Natyieli; Villarroel, Morris; María, Gustavo A; Miranda-de la Lama, Genaro C

    2018-04-01

    Animal welfare has become an important subject of public, economic and political concern, leading to the need to validate indicators that are feasible to use at abattoirs. A systematic review was carried out, which identified 72 cattle welfare indicators (CWI) that were classified into four categories (physiological, morphometric, behavioral and meat quality). Their validity and feasibility for use in abattoirs were evaluated as potential measures of cattle welfare during transportation to the abattoir and at the abattoir itself. Several highly valid indicators were identified that are useful to assess welfare at abattoirs, including body condition score, human-animal interactions, vocalizations, falling, carcass bruising, and meat pH. In addition, some intermediate valid indicators are useful and should be investigated further. Information along the food chain could be used systematically to provide a basis for a more-risk-based meat inspection. An integrated system based on the use of key indicators defined for each inspection step with the setting of alarm thresholds could be implemented. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Predictive performance of rainfall thresholds for shallow landslide triggering in Switzerland from daily gridded precipitation data

    NASA Astrophysics Data System (ADS)

    Leonarduzzi, E.; Molnar, P.; McArdell, B. W.

    2017-12-01

    In Switzerland floods are responsible for most of the damage caused by rainfall-triggered natural hazards (89%), followed by landslides (6%, almost 600 M USD) as reported in Hilker et al. (2009) for the period 1972-2007. A high-resolution gridded daily precipitation dataset is combined with a landslide inventory containing over 2000 events in the period 1972-2012 to analyze rainfall thresholds that lead to landsliding in Switzerland. First triggering rainfall and landslides are co-located obtaining the distributions of triggering and non-triggering rainfall event properties at the scale of the precipitation data (2*2 km2) and considering 1 day as the interarrival time to separate events. Then rainfall thresholds are obtained by maximizing true positives (accurate predictions) while minimizing false negatives (false alarms), using the True Skill Statistic. The best predictive performance is obtained by the intensity-duration ID threshold curve, followed by peak daily intensity (Imax) and mean event intensity (Imean). Event duration by itself has very low predictive power. In addition to country-wide thresholds, local ones are also defined by regionalization based on surface erodibility and local long-term climate (mean daily precipitation). Different Imax thresholds are determined for each of the regions separately. It is found that wetter local climate and lower erodibility lead to significantly higher rainfall thresholds required to trigger landslides. However, the improvement in model performance due to regionalization is marginal and much lower than what can be achieved by having a high quality landslide database. In order to validate the performance of the Imax rainfall threshold model, reference cases will be presented in which the landslide locations and timing are randomized and the landslide sample size is reduced. Jack-knife and cross-validation experiments demonstrate that the model is robust. The results highlight the potential of using rainfall I-D threshold curves and Imax threshold values for predicting the occurrence of landslides on a country or regional scale even with daily precipitation data, with possible applications in landslide warning systems.

  6. Development of Fire Detection Algorithm at Its Early Stage Using Fire Colour and Shape Information

    NASA Astrophysics Data System (ADS)

    Suleiman Abdullahi, Zainab; Hamisu Dalhatu, Shehu; Hassan Abdullahi, Zakariyya

    2018-04-01

    Fire can be defined as a state in which substances combined chemically with oxygen from the air and give out heat, smoke and flame. Most of the conventional fire detection techniques such as smoke, fire and heat detectors respectively have a problem of travelling delay and also give a high false alarm. The algorithm begins by loading the selected video clip from the database developed to identify the present or absence of fire in a frame. In this approach, background subtraction was employed. If the result of subtraction is less than the set threshold, the difference is ignored and the next frame is taken. However, if the difference is equal to or greater than the set threshold then it subjected to colour and shape test. This is done by using combined RGB colour model and shape signature. The proposed technique was very effective in detecting fire compared to those technique using only motion or colour clues.

  7. Automated surveillance of 911 call data for detection of possible water contamination incidents.

    PubMed

    Haas, Adam J; Gibbons, Darcy; Dangel, Chrissy; Allgeier, Steve

    2011-03-30

    Drinking water contamination, with the capability to affect large populations, poses a significant risk to public health. In recent water contamination events, the impact of contamination on public health appeared in data streams monitoring health-seeking behavior. While public health surveillance has traditionally focused on the detection of pathogens, developing methods for detection of illness from fast-acting chemicals has not been an emphasis. An automated surveillance system was implemented for Cincinnati's drinking water contamination warning system to monitor health-related 911 calls in the city of Cincinnati. Incident codes indicative of possible water contamination were filtered from all 911 calls for analysis. The 911 surveillance system uses a space-time scan statistic to detect potential water contamination incidents. The frequency and characteristics of the 911 alarms over a 2.5 year period were studied. During the evaluation, 85 alarms occurred, although most occurred prior to the implementation of an additional alerting constraint in May 2009. Data were available for analysis approximately 48 minutes after calls indicating alarms may be generated 1-2 hours after a rapid increase in call volume. Most alerts occurred in areas of high population density. The average alarm area was 9.22 square kilometers. The average number of cases in an alarm was nine calls. The 911 surveillance system provides timely notification of possible public health events, but did have limitations. While the alarms contained incident codes and location of the caller, additional information such as medical status was not available to assist validating the cause of the alarm. Furthermore, users indicated that a better understanding of 911 system functionality is necessary to understand how it would behave in an actual water contamination event.

  8. Automated surveillance of 911 call data for detection of possible water contamination incidents

    PubMed Central

    2011-01-01

    Background Drinking water contamination, with the capability to affect large populations, poses a significant risk to public health. In recent water contamination events, the impact of contamination on public health appeared in data streams monitoring health-seeking behavior. While public health surveillance has traditionally focused on the detection of pathogens, developing methods for detection of illness from fast-acting chemicals has not been an emphasis. Methods An automated surveillance system was implemented for Cincinnati's drinking water contamination warning system to monitor health-related 911 calls in the city of Cincinnati. Incident codes indicative of possible water contamination were filtered from all 911 calls for analysis. The 911 surveillance system uses a space-time scan statistic to detect potential water contamination incidents. The frequency and characteristics of the 911 alarms over a 2.5 year period were studied. Results During the evaluation, 85 alarms occurred, although most occurred prior to the implementation of an additional alerting constraint in May 2009. Data were available for analysis approximately 48 minutes after calls indicating alarms may be generated 1-2 hours after a rapid increase in call volume. Most alerts occurred in areas of high population density. The average alarm area was 9.22 square kilometers. The average number of cases in an alarm was nine calls. Conclusions The 911 surveillance system provides timely notification of possible public health events, but did have limitations. While the alarms contained incident codes and location of the caller, additional information such as medical status was not available to assist validating the cause of the alarm. Furthermore, users indicated that a better understanding of 911 system functionality is necessary to understand how it would behave in an actual water contamination event. PMID:21450105

  9. Detection of Stimulus Displacements Across Saccades is Capacity-Limited and Biased in Favor of the Saccade Target

    PubMed Central

    Irwin, David E.; Robinson, Maria M.

    2015-01-01

    Retinal image displacements caused by saccadic eye movements are generally unnoticed. Recent theories have proposed that perceptual stability across saccades depends on a local evaluation process centered on the saccade target object rather than on remapping and evaluating the positions of all objects in a display. In three experiments, we examined whether objects other than the saccade target also influence perceptual stability by measuring displacement detection thresholds across saccades for saccade targets and a variable number of non-saccade objects. We found that the positions of multiple objects are maintained across saccades, but with variable precision, with the saccade target object having priority in the perception of displacement, most likely because it is the focus of attention before the saccade and resides near the fovea after the saccade. The perception of displacement of objects that are not the saccade target is affected by acuity limitations, attentional limitations, and limitations on memory capacity. Unlike previous studies that have found that a postsaccadic blank improves the detection of displacement direction across saccades, we found that postsaccadic blanking hurt the detection of displacement per se by increasing false alarms. Overall, our results are consistent with the hypothesis that visual working memory underlies the perception of stability across saccades. PMID:26640430

  10. High-sensitivity, high-selectivity detection of chemical warfare agents

    NASA Astrophysics Data System (ADS)

    Pushkarsky, Michael B.; Webber, Michael E.; Macdonald, Tyson; Patel, C. Kumar N.

    2006-01-01

    We report high-sensitivity detection of chemical warfare agents (nerve gases) with very low probability of false positives (PFP). We demonstrate a detection threshold of 1.2ppb (7.7μg/m3 equivalent of Sarin) with a PFP of <1:106 in the presence of many interfering gases present in an urban environment through the detection of diisopropyl methylphosphonate, an accepted relatively harmless surrogate for the nerve agents. For the current measurement time of ˜60s, a PFP of 1:106 corresponds to one false alarm approximately every 23months. The demonstrated performance satisfies most current homeland and military security requirements.

  11. Evaluating a smartphone application to improve child passenger safety and fire safety knowledge and behaviour.

    PubMed

    Omaki, Elise; Shields, Wendy C; McDonald, Eileen; Aitken, Mary E; Bishai, David; Case, James; Gielen, Andrea

    2017-02-01

    Although proven measures for reducing injury due to motor vehicle collision and residential fires exist, the number of families properly and consistently using child passenger restraints and smoke alarms remains low. This paper describes the design of the Safety In Seconds (SIS) 2.0 study, which aims to evaluate the impact of a smartphone app on parents' use of child restraints and smoke alarms. SIS is a multisite randomised controlled trial. Participants are parents of children aged 4-7 years who are visiting the Pediatric Emergency Department or Pediatric Trauma Service. Parents are randomised to receive tailored education about child passenger safety or about fire safety via the SIS smartphone app. A baseline and two follow-up surveys at 3 months and 6 months are conducted. Primary outcomes are: (1) having the correct child restraint for the child's age and size; (2) restraining the child in the back seat of the car; (3) buckling the child up for every ride; (4) having the restraint inspected by a child passenger safety technician; (5) having a working smoke alarm on every level of the home; (6) having hard-wired or lithium battery smoke alarms; (7) having and (8) practising a fire escape plan. Finding ways to communicate with parents about child passenger and fire safety continues to be a research priority. This study will contribute to the evidence about how to promote benefits of proper and consistent child restraint and smoke alarm use. NCT02345941; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Enhancing fire department home visiting programs: results of a community intervention trial.

    PubMed

    Gielen, Andrea C; Shields, Wendy; Frattaroli, Shannon; McDonald, Eileen; Jones, Vanya; Bishai, David; O'Brocki, Raymond; Perry, Elise C; Bates-Hopkins, Barbara; Tracey, Pat; Parsons, Stephanie

    2013-01-01

    This study evaluates the impact of an enhanced fire department home visiting program on community participation and installation of smoke alarms, and describes the rate of fire and burn hazards observed in homes. Communities were randomly assigned to receive either a standard or enhanced home visiting program. Before implementing the program, 603 household surveys were completed to determine comparability between the communities. During a 1-year intervention period, 171 home visits took place with 8080 homes. At baseline, 60% of homes did not have working smoke alarms on every level, 44% had unsafe water temperatures, and 72% did not have carbon monoxide alarms. Residents in the enhanced community relative to those in the standard community were significantly more likely to let the fire fighters into their homes (75 vs 62%). Among entered homes, those in the enhanced community were significantly more likely to agree to have smoke alarms installed (95 vs 92%), to be left with a working smoke alarm on every level of the home (84 vs 78%), and to have more smoke alarms installed per home visited (1.89 vs 1.74). The high baseline rates of home hazards suggest that fire department home visiting programs should take an "all hazards" approach. Community health workers and community partnerships can be effective in promoting fire departments' fire and life safety goals. Public health academic centers should partner with the fire service to help generate evidence on program effectiveness that can inform decision making about resource allocation for prevention.

  13. Development of an alarm sound database and simulator.

    PubMed

    Takeuchi, Akihiro; Hirose, Minoru; Shinbo, Toshiro; Imai, Megumi; Mamorita, Noritaka; Ikeda, Noriaki

    2006-10-01

    The purpose of this study was to develop an interactive software package of alarm sounds to present, recognize and share problems about alarm sounds among medical staff and medical manufactures. The alarm sounds were recorded in variable alarm conditions in a WAV file. The alarm conditions were arbitrarily induced by modifying attachments of various medical devices. The software package that integrated an alarm sound database and simulator was used to assess the ability to identify the monitor that sounded the alarm for the medical staff. Eighty alarm sound files (40MB in total) were recorded from 41 medical devices made by 28 companies. There were three pairs of similar alarm sounds that could not easily be distinguished, two alarm sounds which had a different priority, either low or high. The alarm sound database was created in an Excel file (ASDB.xls 170 kB, 40 MB with photos), and included a list of file names that were hyperlinked to alarm sound files. An alarm sound simulator (AlmSS) was constructed with two modules for simultaneously playing alarm sound files and for designing new alarm sounds. The AlmSS was used in the assessing procedure to determine whether 19 clinical engineers could identify 13 alarm sounds only by their distinctive sounds. They were asked to choose from a list of devices and to rate the priority of each alarm. The overall correct identification rate of the alarm sounds was 48%, and six characteristic alarm sounds were correctly recognized by beetween 63% to 100% of the subjects. The overall recognition rate of the alarm sound priority was only 27%. We have developed an interactive software package of alarm sounds by integrating the database and the alarm sound simulator (URL: http://info.ahs.kitasato-u.ac.jp/tkweb/alarm/asdb.html ). The AlmSS was useful for replaying multiple alarm sounds simultaneously and designing new alarm sounds interactively.

  14. A speeded-up saliency region-based contrast detection method for small targets

    NASA Astrophysics Data System (ADS)

    Li, Zhengjie; Zhang, Haiying; Bai, Jiaojiao; Zhou, Zhongjun; Zheng, Huihuang

    2018-04-01

    To cope with the rapid development of the real applications for infrared small targets, the researchers have tried their best to pursue more robust detection methods. At present, the contrast measure-based method has become a promising research branch. Following the framework, in this paper, a speeded-up contrast measure scheme is proposed based on the saliency detection and density clustering. First, the saliency region is segmented by saliency detection method, and then, the Multi-scale contrast calculation is carried out on it instead of traversing the whole image. Second, the target with a certain "integrity" property in spatial is exploited to distinguish the target from the isolated noises by density clustering. Finally, the targets are detected by a self-adaptation threshold. Compared with time-consuming MPCM (Multiscale Patch Contrast Map), the time cost of the speeded-up version is within a few seconds. Additional, due to the use of "clustering segmentation", the false alarm caused by heavy noises can be restrained to a lower level. The experiments show that our method has a satisfied FASR (False alarm suppression ratio) and real-time performance compared with the state-of-art algorithms no matter in cloudy sky or sea-sky background.

  15. Theory of Aircraft Collision-Avoidance System Design and Evaluation

    DOT National Transportation Integrated Search

    1971-05-01

    The problem of aircraft anti-collision system design and evaluation is discussed in this work. Two evaluation criteria, conflict ratio and probability of missed critical alarm are formulated and are found to be independent of both traffic density and...

  16. Alarm rationalization: practical experience rationalizing alarm configuration for an accelerator subsystem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasemir, Kay; Hartman, Steven M

    2009-01-01

    A new alarm system toolkit has been implemented at SNS. The toolkit handles the Central Control Room (CCR) 'annunciator', or audio alarms. For the new alarm system to be effective, the alarms must be meaningful and properly configured. Along with the implementation of the new alarm toolkit, a thorough documentation and rationalization of the alarm configuration is taking place. Requirements and maintenance of a robust alarm configuration have been gathered from system and operations experts. In this paper we present our practical experience with the vacuum system alarm handling configuration of the alarm toolkit.

  17. Physiologic Monitor Alarm Rates at 5 Children's Hospitals.

    PubMed

    Schondelmeyer, Amanda C; Brady, Patrick W; Goel, Veena V; Cvach, Maria; Blake, Nancy; Mangeot, Colleen; Bonafide, Christopher P

    2018-06-01

    Alarm fatigue has been linked to patient morbidity and mortality in hospitals due to delayed or absent responses to monitor alarms. We sought to describe alarm rates at 5 freestanding children's hospitals during a single day and the types of alarms and proportions of patients monitored by using a point-prevalence, cross-sectional study design. We collected audible alarms on all inpatient units and calculated overall alarm rates and rates by alarm type per monitored patient per day. We found a total of 147,213 alarms during the study period, with 3-fold variation in alarm rates across hospitals among similar unit types. Across hospitals, onequarter of monitored beds were responsible for 71%, 61%, and 63% of alarms in medical-surgical, neonatal intensive care, and pediatric intensive care units, respectively. Future work focused on addressing nonactionable alarms in patients with the highest alarm counts may decrease alarm rates. © 2018 Society of Hospital Medicine.

  18. Smoke alarm tests may not adequately indicate smoke alarm function.

    PubMed

    Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Young, Tracy

    2011-01-01

    Smoke alarms are one of the most promoted prevention strategies to reduce residential fire deaths, and they can reduce residential fire deaths by half. Smoke alarm function can be measured by two tests: the smoke alarm button test and the chemical smoke test. Using results from a randomized trial of smoke alarms, we compared smoke alarm response to the button test and the smoke test. The smoke alarms found in the study homes at baseline were tested, as well as study alarms placed into homes as part of the randomized trial. Study alarms were tested at 12 and 42 months postinstallation. The proportion of alarms that passed the button test but not the smoke test ranged from 0.5 to 5.8% of alarms; this result was found most frequently among ionization alarms with zinc or alkaline batteries. These alarms would indicate to the owner (through the button test) that the smoke alarm was working, but the alarm would not actually respond in the case of a fire (as demonstrated by failing the smoke test). The proportion of alarms that passed the smoke test but not the button test ranged from 1.0 to 3.0%. These alarms would appear nonfunctional to the owner (because the button test failed), even though the alarm would operate in response to a fire (as demonstrated by passing the smoke test). The general public is not aware of the potential for inaccuracy in smoke alarm tests, and burn professionals can advocate for enhanced testing methods. The optimal test to determine smoke alarm function is the chemical smoke test.

  19. Preliminary Development and Evaluation of Lightning Jump Algorithms for the Real-Time Detection of Severe Weather

    NASA Technical Reports Server (NTRS)

    Schultz, Christopher J.; Petersen, Walter A.; Carey, Lawrence D.

    2009-01-01

    Previous studies have demonstrated that rapid increases in total lightning activity (intracloud + cloud-to-ground) are often observed tens of minutes in advance of the occurrence of severe weather at the ground. These rapid increases in lightning activity have been termed "lightning jumps." Herein, we document a positive correlation between lightning jumps and the manifestation of severe weather in thunderstorms occurring across the Tennessee Valley and Washington D.C. A total of 107 thunderstorms were examined in this study, with 69 of the 107 thunderstorms falling into the category of non-severe, and 38 into the category of severe. From the dataset of 69 isolated non-severe thunderstorms, an average peak 1 minute flash rate of 10 flashes/min was determined. A variety of severe thunderstorm types were examined for this study including an MCS, MCV, tornadic outer rainbands of tropical remnants, supercells, and pulse severe thunderstorms. Of the 107 thunderstorms, 85 thunderstorms (47 non-severe, 38 severe) from the Tennessee Valley and Washington D.C tested 6 lightning jump algorithm configurations (Gatlin, Gatlin 45, 2(sigma), 3(sigma), Threshold 10, and Threshold 8). Performance metrics for each algorithm were then calculated, yielding encouraging results from the limited sample of 85 thunderstorms. The 2(sigma) lightning jump algorithm had a high probability of detection (POD; 87%), a modest false alarm rate (FAR; 33%), and a solid Heidke Skill Score (HSS; 0.75). A second and more simplistic lightning jump algorithm named the Threshold 8 lightning jump algorithm also shows promise, with a POD of 81% and a FAR of 41%. Average lead times to severe weather occurrence for these two algorithms were 23 minutes and 20 minutes, respectively. The overall goal of this study is to advance the development of an operationally-applicable jump algorithm that can be used with either total lightning observations made from the ground, or in the near future from space using the GOES-R Geostationary Lightning Mapper.

  20. Defense Technology Objectives of the Joint Warfighting Science and Technology Plan and the Defense Technology Area Plan.

    DTIC Science & Technology

    1997-01-01

    isolated targets, significantly reduce false alarms ( PFA = 0.01/km2), and recognize force structure (e.g., maneuver battalions). During FY97, a laboratory...probability of false alarm ( Pfa ) of 0.3 at an altitude of 500-1,000 ft and at airspeeds of 60-100 kn is planned. Enhanced COBRA optics-including a...hibiting the desired properties and initiate agent sorption assessments. The FY00 goal is to com- plete performance evaluations of candidate

  1. Evaluation and Improvement of Spectral Features for the Detection of Buried Explosive Hazards Using Forward-Looking Ground-Penetrating Radar

    DTIC Science & Technology

    2012-07-01

    cross track direction is calculated. This is accomplished by taking a 101 point horizontal slice of pixels centered on the alarm. Then, a 101 point...Hamming window, is the 101 -length row vector of FLGPR image pixels surrounding alarm A. We then store the first 50 frequency values (excluding the...Figure 3. Illustration of spectral features in the cross track direction and the difference between actual targets and FAs. Eleven rows of 101

  2. Do nuisance alarms decrease functionality of smoke alarms near the kitchen? Findings from a randomised controlled trial.

    PubMed

    Yang, Jingzhen; Jones, Michael P; Cheng, Gang; Ramirez, Marizen; Taylor, Craig; Peek-Asa, Corinne

    2011-06-01

    Many home fires begin in the kitchen. Kitchen smoke alarms are more likely to produce nuisance alarms, but few previous studies have examined the role of alarm sensor and battery types on the functionality of smoke alarms located nearest to the kitchen. Data were analysed from a 2×2 factorial randomised controlled trial conducted in rural Iowa homes (n=628). Enrolled households were randomly assigned into one of four smoke alarm/battery combinations: ionisation/zinc, ionisation/lithium, photoelectric/zinc and photoelectric/lithium. Alarm functionality was determined using a smoke test. Alarm type and battery type were compared using an intent-to-treat analysis. Logistic regression was used to identify factors that might impact the functionality of smoke alarms located nearest to the kitchen 42 months after installation. Photoelectric alarms with lithium batteries had the highest rate of functionality (90.2%), whereas ionisation alarms with carbon/zinc batteries had the lowest (76.5%). Forty-two months following installation, 6.4% more of photoelectric alarms were functional than ionisation alarms, and 7.9% more of alarms with lithium batteries were functional than those with carbon/zinc batteries. Logistic regression revealed that when the indicator of nuisance alarms was included, the effect of alarm type became statistically insignificant and ionisation alarms were less likely to be functional at 42 months, partly due to increased nuisance alarms. Alarm type is an important consideration for certain locations. Photoelectric alarms may be more appropriate for installation nearest to the kitchen despite their increased cost. These findings can help guide consumer choices to increase protection against home fire-related injuries and deaths.

  3. Understanding heart rate alarm adjustment in the intensive care units through an analytical approach.

    PubMed

    Fidler, Richard L; Pelter, Michele M; Drew, Barbara J; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J Matt; Hu, Xiao

    2017-01-01

    Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.

  4. Evaluation of continuous air monitor placement in a plutonium facility.

    PubMed

    Whicker, J J; Rodgers, J C; Fairchild, C I; Scripsick, R C; Lopez, R C

    1997-05-01

    Department of Energy appraisers found continuous air monitors at Department of Energy plutonium facilities alarmed less than 30% of the time when integrated room plutonium air concentrations exceeded 500 DAC-hours. Without other interventions, this alarm percentage suggests the possibility that workers could be exposed to high airborne concentrations without continuous air monitor alarms. Past research has shown that placement of continuous air monitors is a critical component in rapid and reliable detection of airborne releases. At Los Alamos National Laboratory and many other Department of Energy plutonium facilities, continuous air monitors have been primarily placed at ventilation exhaust points. The purpose of this study was to evaluate and compare the effectiveness of exhaust register placement of workplace continuous air monitors with other sampling locations. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories at Los Alamos National Laboratory. An array of laser particle counters positioned in the rooms measured time-resolved aerosol dispersion. Results showed alternative placement of air samplers generally resulted in aerosol detection that was faster, often more sensitive, and equally reliable compared with samplers at exhaust registers.

  5. False Alarms and Overmonitoring: Major Factors in Alarm Fatigue Among Labor Nurses.

    PubMed

    Simpson, Kathleen Rice; Lyndon, Audrey

    2018-06-08

    Nurses can be exposed to hundreds of alarms during their shift, contributing to alarm fatigue. The purposes were to explore similarities and differences in perceptions of clinical alarms by labor nurses caring for generally healthy women compared with perceptions of adult intensive care unit (ICU) and neonatal ICU nurses caring for critically ill patients and to seek nurses' suggestions for potential improvements. Nurses were asked via focus groups about the utility of clinical alarms from medical devices. There was consensus that false alarms and too many devices generating alarms contributed to alarm fatigue, and most alarms lacked clinical relevance. Nurses identified certain types of alarms that they responded to immediately, but the vast majority of the alarms did not contribute to their clinical assessment or planned nursing care. Monitoring only those patients who need it and only those physiologic values that are warranted, based on patient condition, may decrease alarm burden.

  6. Earthquake prediction evaluation standards applied to the VAN Method

    NASA Astrophysics Data System (ADS)

    Jackson, David D.

    Earthquake prediction research must meet certain standards before it can be suitably evaluated for potential application in decision making. For methods that result in a binary (on or off) alarm condition, requirements include (1) a quantitative description of observables that trigger an alarm, (2) a quantitative description, including ranges of time, location, and magnitude, of the predicted earthquakes, (3) documented evidence of all previous alarms, (4) a complete list of predicted earthquakes, (5) a complete list of unpredicted earthquakes. The VAN technique [Varotsos and Lazaridou, 1991; Varotsos et al., 1996] has not yet been stated as a testable hypothesis. It fails criteria (1) and (2) so it is not ready to be evaluated properly. Although telegrams were transmitted in advance of claimed successes, these telegrams did not fully specify the predicted events, and all of the published statistical evaluations involve many subjective ex post facto decisions. Lacking a statistically demonstrated relationship to earthquakes, a candidate prediction technique should satisfy several plausibility criteria, including: (1) a reasonable relationship between the location of the candidate precursor and that of the predicted earthquake, (2) some demonstration that the candidate precursory observations are related to stress, strain, or other quantities related to earthquakes, and (3) the existence of co-seismic as well as pre-seismic variations of the candidate precursor. The VAN technique meets none of these criteria.

  7. High prices for rare species can drive large populations extinct: the anthropogenic Allee effect revisited.

    PubMed

    Holden, Matthew H; McDonald-Madden, Eve

    2017-09-21

    Consumer demand for plant and animal products threatens many populations with extinction. The anthropogenic Allee effect (AAE) proposes that such extinctions can be caused by prices for wildlife products increasing with species rarity. This price-rarity relationship creates financial incentives to extract the last remaining individuals of a population, despite higher search and harvest costs. The AAE has become a standard approach for conceptualizing the threat of economic markets on endangered species. Despite its potential importance for conservation, AAE theory is based on a simple graphical model with limited analysis of possible population trajectories. By specifying a general class of functions for price-rarity relationships, we show that the classic theory can understate the risk of species extinction. AAE theory proposes that only populations below a critical Allee threshold will go extinct due to increasing price-rarity relationships. Our analysis shows that this threshold can be much higher than the original theory suggests, depending on initial harvest effort. More alarmingly, even species with population sizes above this Allee threshold, for which AAE predicts persistence, can be destined to extinction. Introducing even a minimum price for harvested individuals, close to zero, can cause large populations to cross the classic anthropogenic Allee threshold on a trajectory towards extinction. These results suggest that traditional AAE theory may give a false sense of security when managing large harvested populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES

    PubMed Central

    Perera, Inoka Eranda; Litton, Charles D.

    2015-01-01

    Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m−1 optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters’ Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety. PMID:26229418

  9. EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES.

    PubMed

    Perera, Inoka Eranda; Litton, Charles D

    Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m -1 optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters' Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety.

  10. Research on Vehicle-Based Driver Status/Performance Monitoring, Part III

    DOT National Transportation Integrated Search

    1996-09-01

    A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...

  11. Research On Vehicle-Based Driver Status/Performance Monitoring, Part I

    DOT National Transportation Integrated Search

    1996-09-01

    A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...

  12. Understanding heart rate alarm adjustment in the intensive care units through an analytical approach

    PubMed Central

    Pelter, Michele M.; Drew, Barbara J.; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J. Matt; Hu, Xiao

    2017-01-01

    Background Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. Objectives To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Methods Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). Results There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). Conclusions HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision. PMID:29176776

  13. Enhancing Fire Department Home Visiting Programs: Results of a Community Intervention Trial

    PubMed Central

    Gielen, Andrea C.; Shields, Wendy; Frattaroli, Shannon; McDonald, Eileen; Jones, Vanya; Bishai, David; O’Brocki, Raymond; Perry, Elise C.; Bates-Hopkins, Barbara; Tracey, Pat; Parsons, Stephanie

    2012-01-01

    Background This study evaluates the impact of an enhanced fire department home visiting program on community participation and installation of smoke alarms and describes the rate of fire and burn hazards observed in homes. Methods Communities were randomly assigned to receive either a standard or enhanced home visiting program. Prior to implementing the program, 603 household surveys were completed to determine comparability between the communities. During a one year intervention period, 171 home visit events took place with 8,080 homes. Results At baseline, 60% of homes did not have working smoke alarms on every level; 44% had unsafe water temperatures; and 72% did not have CO alarms. Residents in the enhanced community relative to those in the standard community were significantly more likely to let the fire fighters into their homes (75% vs 62%). Among entered homes, those in the enhanced community were significantly more likely to agree to have smoke alarms installed (95% vs 92%), to be left with a working smoke alarm on every level of the home (84% vs 78%) and to have more smoke alarms installed per home visited (1.89 vs 1.74). Conclusions The high baseline rates of home hazards suggest that fire department home visiting programs should take an “all hazards” approach. CHWs and other community partnerships can be effective in promoting fire departments’ fire and life safety goals. Public health academic centers should partner with the fire service to help generate evidence on program effectiveness that can inform decision making about resource allocation for prevention. PMID:23237821

  14. The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit.

    PubMed

    Joshi, Rohan; Mortel, Heidi van de; Feijs, Loe; Andriessen, Peter; Pul, Carola van

    2017-01-01

    Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient's room within the 90s of the alarm being generated. Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20-52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21-1.78; <0.001) while that of responding to a ventilator alarm was lower at 0.35 (95% CI = 0.27-0.46; p <0.001). For every 20s increase in the duration of an alarm, the odds of responding to the alarm (within 90s) increased to 1.15 (95% CI = 1.1-1.2; p <0.001). The random effect per infant improved the fit of the model to the data with the response times being slower for infants suffering from chronic illnesses while being faster for infants who were clinically unstable. Even though nurses respond to only a fraction of all critical alarms, they consider the vast majority of critical and yellow alarms as useful and relevant. When notified of a critical alarm, they seek waveform information and employ heuristics in determining whether or not to respond to the alarm. Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms.

  15. The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit

    PubMed Central

    van de Mortel, Heidi; Feijs, Loe; Andriessen, Peter; van Pul, Carola

    2017-01-01

    Aim Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. Methods The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient’s room within the 90s of the alarm being generated. Results Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20–52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21–1.78; <0.001) while that of responding to a ventilator alarm was lower at 0.35 (95% CI = 0.27–0.46; p <0.001). For every 20s increase in the duration of an alarm, the odds of responding to the alarm (within 90s) increased to 1.15 (95% CI = 1.1–1.2; p <0.001). The random effect per infant improved the fit of the model to the data with the response times being slower for infants suffering from chronic illnesses while being faster for infants who were clinically unstable. Discussion Even though nurses respond to only a fraction of all critical alarms, they consider the vast majority of critical and yellow alarms as useful and relevant. When notified of a critical alarm, they seek waveform information and employ heuristics in determining whether or not to respond to the alarm. Conclusion Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms. PMID:28981515

  16. Evaluation of a radar-based proximity warning system for off-highway dump trucks.

    PubMed

    Ruff, Todd

    2006-01-01

    A radar-based proximity warning system was evaluated by researchers at the Spokane Research Laboratory of the National Institute for Occupational Safety and Health to determine if the system would be effective in detecting objects in the blind spots of an off-highway dump truck. An average of five fatalities occur each year in surface mines as a result of an equipment operator not being aware of a smaller vehicle, person or change in terrain near the equipment. Sensor technology that can detect such obstacles and that also is designed for surface mining applications is rare. Researchers worked closely with the radar system manufacturer to test and modify the system on large, off-highway dump trucks at a surface mine over a period of 2 years. The final system was thoroughly evaluated by recording video images from a camera on the rear of the truck and by recording all alarms from the rear-mounted radar. Data show that the system reliably detected small vehicles, berms, people and other equipment. However, alarms from objects that posed no immediate danger were common, supporting the assertion that sensor-based systems for proximity warning should be used in combination with other devices, such as cameras, that would allow the operator to check the source of any alarm.

  17. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...

  18. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...

  19. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...

  20. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...

  1. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in the...

  2. Type I and Type II error concerns in fMRI research: re-balancing the scale

    PubMed Central

    Cunningham, William A.

    2009-01-01

    Statistical thresholding (i.e. P-values) in fMRI research has become increasingly conservative over the past decade in an attempt to diminish Type I errors (i.e. false alarms) to a level traditionally allowed in behavioral science research. In this article, we examine the unintended negative consequences of this single-minded devotion to Type I errors: increased Type II errors (i.e. missing true effects), a bias toward studying large rather than small effects, a bias toward observing sensory and motor processes rather than complex cognitive and affective processes and deficient meta-analyses. Power analyses indicate that the reductions in acceptable P-values over time are producing dramatic increases in the Type II error rate. Moreover, the push for a mapwide false discovery rate (FDR) of 0.05 is based on the assumption that this is the FDR in most behavioral research; however, this is an inaccurate assessment of the conventions in actual behavioral research. We report simulations demonstrating that combined intensity and cluster size thresholds such as P < 0.005 with a 10 voxel extent produce a desirable balance between Types I and II error rates. This joint threshold produces high but acceptable Type II error rates and produces a FDR that is comparable to the effective FDR in typical behavioral science articles (while a 20 voxel extent threshold produces an actual FDR of 0.05 with relatively common imaging parameters). We recommend a greater focus on replication and meta-analysis rather than emphasizing single studies as the unit of analysis for establishing scientific truth. From this perspective, Type I errors are self-erasing because they will not replicate, thus allowing for more lenient thresholding to avoid Type II errors. PMID:20035017

  3. [Optimized resource mobilization and quality of treatment of severely injured patients through a structured trauma room alarm system].

    PubMed

    Spering, C; Roessler, M; Kurlemann, T; Dresing, K; Stürmer, K M; Lehmann, W; Sehmisch, S

    2017-12-12

    The treatment of severely injured patients in the trauma resuscitation unit (TRU) requires an interdisciplinary and highly professional trauma team approach. The complete team needs to be waiting for the patient in the TRU on arrival. Treating severely injured patients in the TRU, the trauma team connects the initial preclinical emergency stabilization with the subsequent sophisticated treatment. Thus, the trauma team depends on concise information from the emergency personnel at the scene to provide its leader with further information as well as an accurate alarm including all departments necessary to stabilize the patient in the TRU. Aiming at an accurate and most efficient trauma team alarm, this study was designed to provide and analyze an alarm system which mobilizes the trauma team in a stepwise fashion depending on the pattern of injuries and the threat to life. The trauma team alarm system was analyzed in a prospective data acquisition at a level I trauma center over a period of 12 months. Evaluation followed the acquisition phase and provided comparison to the status prior to the establishment of the alarm system. All items underwent statistical testing using t‑tests (p < 0.05). The data of 775 TRU patients showed a significant reduction of false information on the patients status prior to arrival. It also showed an increase in punctual arrival in the TRU of the emergency teams. False alarms were significantly reduced (from 11.9% to 2.7%, p > 0.01). The duration from arrival of the patient in the TRU to the initial multislice computed tomography (CT) scan was reduced by 6 min while the total period of treatment in the TRU was reduced by 17 min. After the alarm system to gradually mobilize the trauma team was put into action, team members left the TRU if unneeded prior to finishing the initial treatment in only 4% of the cases. The patient fatality rate was 8.8% (injury severity score, ISS = 23 points) after establishment of the alarm system compared to 12.9% (ISS = 25 points) before. The implementation of an accurate and patient status-based alarm system to mobilize the trauma team can improve the quality of treatment while the duration of treatment of the severely injured patients in the TRU can be decreased. It also provides a most efficient mobilization of personnel resources while sustaining patient safety.

  4. Causal simulation and sensor planning in predictive monitoring

    NASA Technical Reports Server (NTRS)

    Doyle, Richard J.

    1989-01-01

    Two issues are addressed which arise in the task of detecting anomalous behavior in complex systems with numerous sensor channels: how to adjust alarm thresholds dynamically, within the changing operating context of the system, and how to utilize sensors selectively, so that nominal operation can be verified reliably without processing a prohibitive amount of sensor data. The approach involves simulation of a causal model of the system, which provides information on expected sensor values, and on dependencies between predicted events, useful in assessing the relative importance of events so that sensor resources can be allocated effectively. The potential applicability of this work to the execution monitoring of robot task plans is briefly discussed.

  5. Scanning seismic intrusion detection method and apparatus. [monitoring unwanted subterranean entry and departure

    NASA Technical Reports Server (NTRS)

    Lee, R. D. (Inventor)

    1983-01-01

    An intrusion monitoring system includes an array of seismic sensors, such as geophones, arranged along a perimeter to be monitored for unauthorized intrusion as by surface movement or tunneling. Two wires lead from each sensor to a central monitoring station. The central monitoring station has three modes of operation. In a first mode of operation, the output of all of the seismic sensors is summed into a receiver for amplification and detection. When the amplitude of the summed signals exceeds a certain predetermined threshold value an alarm is sounded. In a second mode of operation, the individual output signals from the sensors are multiplexed into the receiver for sequentially interrogating each of the sensors.

  6. Six-month follow-up of lithium-battery smoke alarms and self-reported reasons for disabling.

    PubMed

    Omaki, Elise; Shields, Wendy C; Frattaroli, Shannon; McDonald, Eileen; Jones, Vanya; Gielen, Andrea

    2017-02-01

    Although smoke alarms with lithium batteries are often marketed as '10-year alarms', on average, these alarms do not remain functional for 10 years. This paper describes self-reported reasons for non-working lithium-battery alarms 6-9 months following a smoke alarm installation programme. Data presented are for a cohort of 754 homes that participated in the installation programme and subsequently completed follow-up. A total of 1487 smoke alarms were installed. At follow-up, 126 alarms (8%) were missing and 37 (3%) were observed to be non-working. Of the non-working alarms, residents reported that they had been disabled 57% of the time. Reasons for disabling the alarms most often included that the battery was chirping (38%) or that it sounded while someone was cooking (24%). Smoke alarm installation programmes using lithium-battery alarms should consider highlighting education about smoke alarm maintenance, the hush feature and resources to replace alarms that malfunction soon after installation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Controlled trial of standard pad and bell alarm against mini alarm for nocturnal enuresis.

    PubMed Central

    Fordham, K E; Meadow, S R

    1989-01-01

    Fifty six children aged from 6-16 years who wet their beds at night were entered into a controlled trial of two alarm devices: a traditional alarm using a wet sensor mat on the bed attached to an alarm bell out of reach of the child, and a mini alarm system incorporating a tiny perineal wet sensor attached to a small alarm worn on the child's clothing. A quota allocation system ensured comparability between the two treatment groups. The children were encouraged to use the alarm for four months. Both alarms were equally effective in helping children to become dry. There was no significant difference between the number of children unable to comply with treatment or to be helped by each alarm. The rate of acquisition of dryness was similar for the two groups. The traditional standard alarm was sturdier, more dependable, and easier to maintain, but the mini alarm had some advantages, particularly for girls. Both types of alarm are recommended for general use. Images Fig 1 Fig 2 PMID:2658853

  8. Towards a debris-flow warning system based on hydrological measurements of the triggering conditions. A study of El Rebaixader catchment (Central Pyrenees, Spain)

    NASA Astrophysics Data System (ADS)

    Abancó, Clàudia; Hürlimann, Marcel; Moya, José

    2014-05-01

    Debris flows represent a risk to the society due to their high destructive power. Rainfall is the main debris-flow triggering factor. Rainfall thresholds are generally used for warning of debris flow occurrence in susceptible catchments. However, the efficiency of such thresholds for real time hazard assessment is often conditioned by many factors, such as: the location and number of the rain gauges used (both to define the thresholds, and for setting off warnings); the temporal and spatial evolution of rainfall's convective cells or the effect of snow cover melting. These factors affect the length of the warning time, which is of crucial importance for issuing alert messages or alarms to the people and infrastructures at risk. The Rebaixader catchment (Central Pyrenees, Spain) is being monitored since 2009 by six stations recording information on initiation (4 stations) and flow detection and cinematic behaviour (2 stations). Until December 2013, 7 debris flows, 17 debris floods and 4 rockfalls have been recorded. The objectives of this work were: a) the definition of rainfall thresholds at two different rain gauges; b) the analysis of the infiltration patterns in order to define their potential use for warning systems and c) preliminary testing of rainfall thresholds' efficiency in terms of warning time, in this catchment. This last goal consisted in the comparison of the time elapsed between the rainfall threshold was exceeded and the event occurrence was detected by the stations at the channel area. The results suggest that the intensity-duration rainfall thresholds sometimes provide warning times which would be too short for an adequate reaction in the Rebaixader catchment (less than 10 minutes). The combination of such rainfall thresholds with infiltration measurements is useful to increase the warning time. This occurs especially in the events triggered in spring, when the snowmelt plays an important role in the event's triggering conditions. However, the effects of infiltration associated to the summer convective rainfalls are almost imperceptible; therefore their importance in warning systems decreases.

  9. A test of the acoustic adaptation hypothesis in four species of marmots.

    PubMed

    Daniel; Blumstein

    1998-12-01

    Acoustic signals must be transmitted from a signaller to a receiver during which time they become modified. The acoustic adaptation hypothesis suggests that selection should shape the structure of long-distance signals to maximize transmission through different habitats. A specific prediction of the acoustic adaptation hypothesis is that long-distance signals of animals in their native habitat are expected to change less during transmission than non-native signals within that habitat. This prediction was tested using the alarm calls of four species of marmots that live in acoustically different habitats and produce species-specific, long-distance alarm vocalizations: yellow-bellied marmot, Marmota flaviventris; Olympic marmot, M. olympus; hoary marmot, M. caligata; and woodchuck, M. monax. By doing so, we evaluated the relative importance the acoustic environment plays on selecting for divergent marmot alarm calls. Representative alarm calls of the four species were broadcast and rerecorded in each species' habitat at four distances from a source. Rerecorded, and therefore degraded alarm calls, were compared to undegraded calls using spectrogram correlation. If each species' alarm call was transmitted with less overall degradation in its own environment, a significant interaction between species' habitat and species' call type would be expected. Transmission fidelity at each of four distances was treated as a multivariate response and differences among habitat and call type were tested in a two-way MANOVA. Although significant overall differences in the transmission properties of the habitats were found, and significant overall differences in the transmission properties of the call types were found, there was no significant interaction between habitat and call type. Thus, the evidence did not support the acoustic adaptation hypothesis for these marmot species. Factors other than maximizing long-distance transmission through the environment may be important in the evolution of species-specific marmot alarm calls. (c) 1998 The Association for the Study of Animal Behaviour.

  10. How long do smoke alarms function? A cross-sectional follow-up survey of a smoke alarm installation programme.

    PubMed

    McCoy, Mary A; Roper, Carey; Campa, Emily; Stephens-Stidham, Shelli; Carlin, Debra K; Istre, Gregory R

    2014-04-01

    To assess the functionality of lithium-powered smoke alarms that had been installed through a community-based programme called Operation Installation (OI). A random sample was chosen of homes that had received smoke alarms through OI, 2, 4, 6, 8 and 10 years previously. Sampled homes were visited, and information collected included functional status of smoke alarms. For homes in the 6-, 8- and 10-year sample, smoke alarms were removed and tested for battery and alarm function. 800 homes were included in the survey results; 1884 smoke alarms had been installed through OI. The proportion of homes that had at least one functioning OI smoke alarm ranged from 91.8% for year 2 sample to 19.8% for year 10. Of the originally installed smoke alarms in year 10 sample, 45.5% had been removed and 59% (64/108) of those that were still installed were not functioning. Multivariate analysis showed that the presence of at least one working alarm in the home was associated positively with the number of smoke alarms that were originally installed and whether the original occupant was still living in the home, and negatively with the length of time since the smoke alarm was installed, and whether there was a smoker in the home. Testing of the smoke alarms revealed that most non-functioning alarms had missing or dead batteries. Less than a quarter of the originally installed smoke alarms were still present and functioning by year 10. These findings have important implications for smoke alarm installation programmes.

  11. Use of statistical analysis of long term displacement rate time series for the definition of Early Warning thresholds. The case studies of the Ruinon and Mont de La Saxe landslides (N Italy)

    NASA Astrophysics Data System (ADS)

    Alberti, Stefano; Battista Crosta, Giovanni; Rivolta, Carlo

    2016-04-01

    Rockslides are characterized by complex spatial and temporal evolution. Forecasting their behaviour is a hard task, due to non-linear displacement trends and the significant effects of seasonal or occasional events. The displacement rate and the landslide evolution are influenced by various factors like lithology, structural and hydrological settings, as well as meteo-climatic factors (e.g. snowmelt and rainfall). The nature of the relationships among these factors is clearly non linear, site specific and even specific to each sector that can be individuated within the main landslide mass. In this contribution, total displacement and displacement rate time series are extracted from Ground-based Interferometric synthetic aperture radar (GB-InSAR) surveys, monitoring of optical targets by total stations, a GPS network and multi-parametric borehole probes. Different Early Warning domains, characterized by different velocity regimes (slow to fast domains) and with different sensitivity to external perturbations (e.g. snowmelt and rainfall), have been identified in previous studies at the two sites. The Mont de La Saxe rockslide (ca. 8 x 106 m3) is located in the Upper Aosta Valley, and it has been intensively monitored since 2009 by the Valle D'Aosta Geological Survey. The Ruinon landslide (ca. 15 x 106 to 20 x 106 m3) is located in the Upper Valtellina (Lombardy region) and monitoring data are available starting since 2006 and have been provided by ARPA Lombardia. Both phenomena are alpine deep-seated rockslides characterized by different displacement velocity, from few centimetres to over 1 meter per year, and which have undergone exceptional accelerations during some specific events. We experiment the use of normal probability plots for the analysis of displacement rates of specific points belonging to different landslide sectors and recorded during almost ten years of monitoring. This analyses allow us to define: (i) values with a specific probability value expressed in terms of percentiles; (ii) values for which a specific change in behaviour is observed which could be associated to a specific type of triggering event (e.g. rainfall intensity, duration or amount; snowmelt amount) . These values could be used to support the choice of threshold values for the management of Early Warning System, by considering also the minimization of false alarms. The analyses have been performed by using data averaged over different time intervals so to study the effects of noise on the threshold values. Analyses of false alarm triggered by the choice of different threshold values (i.e. different percentiles) have been performed and analysed. This could be an innovative approach to define velocity thresholds of Early Warning system and to analyse the quantitative data derived from remote sensing monitoring and filed surveys, by linking them to both spatial and temporal changes.

  12. The Politics of Legislative Evaluations: Fire-Alarm and Police Patrol as Oversight Procedures.

    ERIC Educational Resources Information Center

    Wohlstetter, Priscilla

    1990-01-01

    Means by which state legislatures practice evaluation are examined by analyzing oversight strategies for monitoring recent educational reforms in Arizona, California, Florida, Georgia, Minnesota, and Pennsylvania. Focus is on the inextricable link between politics and oversight; the oversight strategy and methods for policy evaluation are largely…

  13. Reducing SCADA System Nuisance Alarms in the Water Industry in Northern Ireland.

    PubMed

    O'Donoghue, Nigel; Phillips, Debra H; Nicell, Ciaran

    2015-08-01

    The advancement of telemetry control for the water industry has increased the difficulty of managing large volumes of nuisance alarms (i.e., alarms that do not require a response). The aim of this study was to identify and reduce the number of nuisance alarms that occur for Northern Ireland (NI) Water by carrying out alarm duration analysis to determine the appropriate length of persistence (an advanced alarm management tool) that could be applied. All data were extracted from TelemWeb (NI Water's telemetry monitoring system) and analyzed in Excel. Over a 6-week period, an average of 40 000 alarms occurred per week. The alarm duration analysis, which has never been implemented before by NI Water, found that an average of 57% of NI Water alarms had a duration of <5 minutes. Applying 5-minute persistence, therefore, could prevent an average 26 816 nuisance alarms per week. Most of these alarms were from wastewater assets.

  14. Fault Diagnosis with Multi-State Alarms in a Nuclear Power Control Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuart A. Ragsdale; Roger Lew; Ronald L. Boring

    2014-09-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effects of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized the use of three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. Sensitivity and criterion based on the Signal Detection Theory were used to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed bettermore » and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.« less

  15. Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue

    PubMed Central

    Tarriela, Albert Fajardo; Gomez, Tiffany Michelle; Reed, Charles Calhoun; Rapp, Kami Marie

    2015-01-01

    Background Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step toward this requirement is identifying ICU nurses’ perceptions and common clinical practices toward clinical alarms, where little information is available. Objective Our aim was to determine perceptions and practices of transplant/cardiac ICU (TCICU) nurses toward clinical alarms and benchmark the results against the 2011 Healthcare Technology Foundation’s (HTF) Clinical Alarms Committee Survey. Methods A quality improvement project was conducted on a 20-bed TCICU with 39 full- and part-time nurses. Nurses were surveyed about their perceptions and attitudes toward and practices on clinical alarms using an adapted HTF clinical alarms survey. Results were compared to the 2011 HTF data. Correlations among variables were examined. Results All TCICU nurses provided usable responses (N=39, 100%). Almost all nurses (95%-98%) believed that false alarms are frequent, disrupt care, and reduce trust in alarm systems, causing nurses to inappropriately disable them. Unlike the 2011 HTF clinical alarms survey results, a significantly higher percentage of our TCICU nurses believed that existing devices are complex, questioned the ability and adequacy of the new monitoring systems to solve alarm management issues, pointed to the lack of prompt response to alarms, and indicated the lack of clinical policy on alarm management (P<.01). Major themes in the narrative data focused on nurses’ frustration related to the excessive number of alarms and poor usability of the cardiac monitors. A lack of standardized approaches exists in changing patients’ electrodes and individualizing parameters. Around 60% of nurses indicated they received insufficient training on bedside and central cardiac monitors. A correlation also showed the need for training on cardiac monitors, specifically for older nurses (P=.01). Conclusions False and non-actionable alarms continue to desensitize TCICU nurses, perhaps resulting in missing fatal alarms. Nurses’ attitudes and practices related to clinical alarms are key elements for designing contextually sensitive quality initiatives to fight alarm fatigue. Alarm management in ICUs is a multidimensional complex process involving usability of monitoring devices, and unit, clinicians, training, and policy-related factors. This indicates the need for a multi-method approach to decrease alarm fatigue and improve alarm systems safety. PMID:27025940

  16. Technological Distractions (Part 2): A Summary of Approaches to Manage Clinical Alarms With Intent to Reduce Alarm Fatigue.

    PubMed

    Winters, Bradford D; Cvach, Maria M; Bonafide, Christopher P; Hu, Xiao; Konkani, Avinash; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; Pelter, Michele M; McLean, Barbara; Kane-Gill, Sandra L

    2018-01-01

    Alarm fatigue is a widely recognized safety and quality problem where exposure to high rates of clinical alarms results in desensitization leading to dismissal of or slowed response to alarms. Nonactionable alarms are thought to be especially problematic. Despite these concerns, the number of clinical alarm signals has been increasing as an everincreasing number of medical technologies are added to the clinical care environment. PubMed, SCOPUS, Embase, and CINAHL. We performed a systematic review of the literature focused on clinical alarms. We asked a primary key question; "what interventions have been attempted and resulted in the success of reducing alarm fatigue?" and 3-secondary key questions; "what are the negative effects on patients/families; what are the balancing outcomes (unintended consequences of interventions); and what human factor approaches apply to making an effective alarm?" Articles relevant to the Key Questions were selected through an iterative review process and relevant data was extracted using a standardized tool. We found 62 articles that had relevant and usable data for at least one key question. We found that no study used/developed a clear definition of "alarm fatigue." For our primary key question 1, the relevant studies focused on three main areas: quality improvement/bundled activities; intervention comparisons; and analysis of algorithm-based false and total alarm suppression. All sought to reduce the number of total alarms and/or false alarms to improve the positive predictive value. Most studies were successful to varying degrees. None measured alarm fatigue directly. There is no agreed upon valid metric(s) for alarm fatigue, and the current methods are mostly indirect. Assuming that reducing the number of alarms and/or improving positive predictive value can reduce alarm fatigue, there are promising avenues to address patient safety and quality problem. Further investment is warranted not only in interventions that may reduce alarm fatigue but also in defining how to best measure it.

  17. Association between the proportion of sampled transition cows with increased nonesterified fatty acids and beta-hydroxybutyrate and disease incidence, pregnancy rate, and milk production at the herd level.

    PubMed

    Ospina, P A; Nydam, D V; Stokol, T; Overton, T R

    2010-08-01

    In this study the herd alarm level was defined as the proportion of sampled transition cows per herd with increased prepartum nonesterified fatty acid (NEFA), postpartum beta-hydroxybutyrate (BHBA), or NEFA concentrations that were associated with herd-level incidence of displaced abomasum (DA) or clinical ketosis (CK), pregnancy rate (PR), and milk production. The objectives were to 1) identify the herd alarm level for excessive negative energy balance and 2) describe the herd-level prevalence of this proportion. This was a prospective cohort study of 60 free-stall herds fed total mixed rations in the northeast United States. Two cohorts of approximately 15 animals were assessed for prepartum NEFA and postpartum BHBA and NEFA. The herd alarm level (i.e., the proportion of sampled animals above a certain metabolite threshold) was as follows: 15% had prepartum NEFA of 0.27 mEq/L; 15 and 20% had BHBA of 10 and 12 mg/dL, respectively; and 15% had postpartum NEFA of 0.60 and 0.70 mEq/L. The different herd alarm levels correspond to differences between the metabolites and respective herd-level effect. The herd-level effects for herds above the herd alarm level for prepartum NEFA were 3.6% increase in DA and CK incidence, 1.2% decrease in PR, and 282 kg decrease in average mature equivalent 305-d (ME 305) milk. For BHBA, the herd-level effects were a 1.8% increase in DA and CK, 0.8% decrease in PR, and 534 and 358 kg decrease in projected ME 305 milk yield for heifers and cows, respectively. For postpartum NEFA, the herd-level effects were 1.7% increase in DA and CK, 0.9% decrease in PR, and 288 and 593 kg decrease in projected ME 305 milk yield for heifers and cows, respectively. The prevalence of herds in which more than 15% of animals sampled had prepartum NEFA concentration >or=0.30 mEq/L was 75%, BHBA >or=12 mg/dL was 40%, and postpartum NEFA >or=0.70 mEq/L was 65%. This study showed that there were detrimental herd-level effects if a large enough proportion of cows had increased metabolite concentrations, and further demonstrated that a high prevalence of herds have opportunity for improvement. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Primary nocturnal enuresis in children. Background and treatment.

    PubMed

    Wille, S

    1994-01-01

    The aim of the present studies was to investigate background factors and treatment in children with monosymptomatic primary nocturnal enuresis. The study material comprised enuretics, former enuretics and controls from the municipal community of Falkenberg on the west coast of Sweden. Whenever possible all investigations were made with the children staying in their own home environment. Different background factors have been suspected as being causative: sleep disturbances, behavioural or psychological disturbances, small bladder capacity, increased night diuresis and an insufficient production of the antidiuretic hormone during sleep. These factors have been investigated in these studies. The treatment of enuresis has been dominated by the alarm and antidiuretic treatment with DDAVP. Primary nocturnal monosymptomatic enuresis is a common problem in childhood. In this study the prevalence among 392 seven year old children was 7.3%. A prior history of enuresis was found in 65% of families of the enuretics compared to 25% in controls. The enuretic children showed no statistically significant differences in behavioural or psychological problems compared to non-enuretic children. Enuretic children were described as heavy sleepers by their parents and a wake-up test performed at home showed that they were statistically significantly harder to arouse than the controls. Children with nocturnal enuresis, former enuretics and controls did not differ in social or behavioural traits in an interview study. No signs of symptom substitution was found when enuresis was resolved. Enuretic children had a normal bladder capacity and no statistically significant difference was found compared to controls and former enuretics. The enuretic children showed a normal calcium-creatinine quota in the urine. Former enuretic children showed a significantly enhanced calcium/creatinine quota compared to enuretics and controls. Enuretic children had a statistically significant lower morning plasma level of the anti diuretic hormone vasopressin than non-enuretic children. Enuretic children were treated for 12 weeks with DDAVP or the alarm. DDAVP treated patients had a more rapid effect compared with alarm treated patients. Alarm treated children had a lower relapse frequency. Enuretic children were treated in a randomised, double blind, double dummy, cross over, placebo-controlled study with DDAVP 20 micrograms intranasally by a single dose pipette or 200 micrograms orally as a tablet. Both methods were equally effective in controlling enuresis, but significantly superior to placebo. Enuretic children are normal, well adjusted children with a normal bladder capacity, a high level of arousal threshold, and a low morning level of plasma vasopressin. The alarm and DDAVP are equally effective in treating enuresis.(ABSTRACT TRUNCATED AT 400 WORDS)

  19. Comparison of a personalized parent voice smoke alarm with a conventional residential tone smoke alarm for awakening children.

    PubMed

    Smith, Gary A; Splaingard, Mark; Hayes, John R; Xiang, Huiyun

    2006-10-01

    Conventional residential tone smoke alarms fail to awaken the majority of children during slow wave sleep. With the objective of identifying a more effective smoke alarm for children, we compared a personalized parent voice smoke alarm with a conventional residential tone smoke alarm, both presented at 100 dB, with respect to their ability to awaken children 6- to 12-years-old from stage 4 sleep and prompt their performance of a simulated self-rescue escape procedure. Using a randomized, nonblinded, clinical research design, a volunteer sample of healthy children 6- to 12-years-old was enrolled in the study. Children were trained how to perform a simulated self-rescue escape procedure when they heard a smoke alarm. Each child's mother recorded a voice alarm message, "First name! First name! Wake up! Get out of bed! Leave the room!" For each child, either the voice or tone smoke alarm was randomly selected and triggered during the first cycle of stage 4 sleep, and then the other alarm was triggered during the second cycle of stage 4 sleep. Children's sleep stage was monitored by electroencephalography, electro-oculography, and chin electromyography. The 4 main outcome measures included the number of children who awakened, the number of children who escaped, the time to awakening, and the time to escape. Twenty-four children were enrolled. The median age was 9 years, and 11 (46%) were boys. One half of the children received the parent voice alarm first, and one half received the tone alarm first; however, the order that the alarm stimuli were presented was not statistically associated with awakening or escaping. Twenty-three (96%) of the 24 subjects awakened to the parent voice alarm compared with 14 (58%) to the tone alarm. One child did not awaken to either stimulus. Nine children awakened to their parent's voice but not to the tone, whereas none awakened to only the tone and not the voice. Twenty (83%) of the subjects in the parent voice alarm group successfully performed the escape procedure within 5 minutes of alarm onset compared with 9 (38%) in the tone alarm group. The median time to awaken was 20 seconds in the voice alarm group compared with 3 minutes in the tone alarm group. The median time to escape was 38 seconds in the voice alarm group compared with the maximum allowed 5 minutes in the tone alarm group. When exposed to the tone alarm, older children were more likely to awaken and were more likely to escape than younger children. There was no association between child's age and awakening or escaping for children exposed to the parent voice alarm. There was no association between child's gender and awakening or escaping for either alarm type. To our knowledge, this study is the first to compare the ability of different types of smoke alarms to awaken children while monitoring sleep stage. The personalized parent voice smoke alarm at 100 dB successfully awakened 96% of children 6- to 12-years-old from stage 4 sleep with 83% successfully performing a simulated self-rescue escape procedure, significantly outperforming the 100-dB conventional residential tone smoke alarm. These findings suggest a clear direction for future research, as well as important fundamental changes in smoke alarm design, that address the unique developmental needs of children. The development of a more effective smoke alarm for use in homes and other locations where children sleep provides an opportunity to reduce fire-related morbidity and mortality among children.

  20. Responses of urban crows to con- and hetero-specific alarm calls in predator and non-predator zoo enclosures.

    PubMed

    Bílá, Kateřina; Beránková, Jana; Veselý, Petr; Bugnyar, Thomas; Schwab, Christine

    2017-01-01

    Urban animals and birds in particular are able to cope with diverse novel threats in a city environment such as avoiding novel, unfamiliar predators. Predator avoidance often includes alarm signals that can be used also by hetero-specifics, which is mainly the case in mixed-species flocks. It can also occur when species do not form flocks but co-occur together. In this study we tested whether urban crows use alarm calls of conspecifics and hetero-specifics (jackdaws, Corvus monedula) differently in a predator and a non-predator context with partly novel and unfamiliar zoo animal species. Birds were tested at the Tiergarten Schönbrunn in the city of Vienna by playing back con- and hetero-specific alarm calls and control stimuli (great tit song and no stimuli) at predator (wolf, polar bear) and non-predator (eland antelope and cranes, peccaries) enclosures. We recorded responses of crows as the percentage of birds flying away after hearing the playback (out of those present before the playback) and as the number of vocalizations given by the present birds. A significantly higher percentage of crows flew away after hearing either con- or hetero-specific alarm calls, but it did not significantly differ between the predator and the non-predator context. Crows treated jackdaw calls just as crow calls, indicating that they make proper use of hetero-specific alarm calls. Responding similarly in both contexts may suggest that the crows were uncertain about the threat a particular zoo animal represents and were generally cautious. In the predator context, however, a high percentage of crows also flew away upon hearing the great tit control song which suggests that they may still evaluate those species which occasionally killed crows as more dangerous and respond to any conspicuous sound.

  1. Rack protection monitor

    DOEpatents

    Orr, Stanley G.

    2000-01-01

    A hardwired, fail-safe rack protection monitor utilizes electromechanical relays to respond to the detection by condition sensors of abnormal or alarm conditions (such as smoke, temperature, wind or water) that might adversely affect or damage equipment being protected. When the monitor is reset, the monitor is in a detection mode with first and second alarm relay coils energized. If one of the condition sensors detects an abnormal condition, the first alarm relay coil will be de-energized, but the second alarm relay coil will remain energized. This results in both a visual and an audible alarm being activated. If a second alarm condition is detected by another one of the condition sensors while the first condition sensor is still detecting the first alarm condition, both the first alarm relay coil and the second alarm relay coil will be de-energized. With both the first and second alarm relay coils de-energized, both a visual and an audible alarm will be activated. In addition, power to the protected equipment will be terminated and an alarm signal will be transmitted to an alarm central control. The monitor can be housed in a separate enclosure so as to provide an interface between a power supply for the protected equipment and the protected equipment.

  2. Spiny lobsters detect conspecific blood-borne alarm cues exclusively through olfactory sensilla.

    PubMed

    Shabani, Shkelzen; Kamio, Michiya; Derby, Charles D

    2008-08-01

    When attacked by predators, diverse animals actively or passively release molecules that evoke alarm and related anti-predatory behavior by nearby conspecifics. The actively released molecules are alarm pheromones, whereas the passively released molecules are alarm cues. For example, many insects have alarm-signaling systems that involve active release of alarm pheromones from specialized glands and detection of these signals using specific sensors. Many crustaceans passively release alarm cues, but the nature of the cues, sensors and responses is poorly characterized. Here we show in laboratory and field experiments that injured Caribbean spiny lobsters, Panulirus argus, passively release alarm cues via blood (hemolymph) that induce alarm responses in the form of avoidance and suppression of feeding. These cues are detected exclusively through specific olfactory chemosensors, the aesthetasc sensilla. The alarm cues for Caribbean spiny lobsters are not unique to the species but do show some phylogenetic specificity: P. argus responds primarily with alarm behavior to conspecific blood, but with mixed alarm and appetitive behaviors to blood from the congener Panulirus interruptus, or with appetitive behaviors to blood from the blue crab Callinectes sapidus. This study lays the foundation for future neuroethological studies of alarm cue systems in this and other decapod crustaceans.

  3. Comparison of the identification and ease of use of two alarm sound sets by critical and acute care nurses with little or no music training: a laboratory study.

    PubMed

    Atyeo, J; Sanderson, P M

    2015-07-01

    The melodic alarm sound set for medical electrical equipment that was recommended in the International Electrotechnical Commission's IEC 60601-1-8 standard has proven difficult for clinicians to learn and remember, especially clinicians with little prior formal music training. An alarm sound set proposed by Patterson and Edworthy in 1986 might improve performance for such participants. In this study, 31 critical and acute care nurses with less than one year of formal music training identified alarm sounds while they calculated drug dosages. Sixteen nurses used the IEC and 15 used the Patterson-Edworthy alarm sound set. The mean (SD) percentage of alarms correctly identified by nurses was 51.3 (25.6)% for the IEC alarm set and 72.1 (18.8)% for the Patterson-Edworthy alarms (p = 0.016). Nurses using the Patterson-Edworthy alarm sound set reported that it was easier to distinguish between alarm sounds than did nurses using the IEC alarm sound set (p = 0.015). Principles used to construct the Patterson-Edworthy alarm sounds should be adopted for future alarm sound sets. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  4. Novel Maximum-based Timing Acquisition for Spread-Spectrum Communications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sibbetty, Taylor; Moradiz, Hussein; Farhang-Boroujeny, Behrouz

    This paper proposes and analyzes a new packet detection and timing acquisition method for spread spectrum systems. The proposed method provides an enhancement over the typical thresholding techniques that have been proposed for direct sequence spread spectrum (DS-SS). The effective implementation of thresholding methods typically require accurate knowledge of the received signal-to-noise ratio (SNR), which is particularly difficult to estimate in spread spectrum systems. Instead, we propose a method which utilizes a consistency metric of the location of maximum samples at the output of a filter matched to the spread spectrum waveform to achieve acquisition, and does not require knowledgemore » of the received SNR. Through theoretical study, we show that the proposed method offers a low probability of missed detection over a large range of SNR with a corresponding probability of false alarm far lower than other methods. Computer simulations that corroborate our theoretical results are also presented. Although our work here has been motivated by our previous study of a filter bank multicarrier spread-spectrum (FB-MC-SS) system, the proposed method is applicable to DS-SS systems as well.« less

  5. Detecting Intra-Fraction Motion in Patients Undergoing Radiation Treatment Using a Low-Cost Wireless Accelerometer

    PubMed Central

    Farahmand, Farid; Khadivi, Kevin O.; Rodrigues, Joel J. P. C.

    2009-01-01

    The utility of a novel, high-precision, non-intrusive, wireless, accelerometer-based patient orientation monitoring system (APOMS) in determining orientation change in patients undergoing radiation treatment is reported here. Using this system a small wireless accelerometer sensor is placed on a patient’s skin, broadcasting its orientation to the receiving station connected to a PC in the control area. A threshold-based algorithm is developed to identify the exact amount of the patient’s head orientation change. Through real-time measurements, an audible alarm can alert the radiation therapist if the user-defined orientation threshold is violated. Our results indicate that, in spite of its low-cost and simplicity, the APOMS is highly sensitive and offers accurate measurements. Furthermore, the APOMS is patient friendly, vendor neutral, and requires minimal user training. The versatile architecture of the APOMS makes it potentially suitable for variety of applications, including study of correlation between external and internal markers during Image-Guided Radiation Therapy (IGRT), with no major changes in hardware setup or algorithm. PMID:22423196

  6. Comprehensive smoke alarm coverage in lower economic status homes: alarm presence, functionality, and placement.

    PubMed

    Sidman, Elanor A; Grossman, David C; Mueller, Beth A

    2011-08-01

    The objectives of this study are to estimate smoke alarm coverage and adherence with national guidelines in low- to mid-value owner-occupied residences, and to identify resident demographic, behavioral, and building characteristics and other fire and burn safety practices associated with smoke alarm utilization. Baseline visits were conducted with 779 households in King County, Washington, for a randomized trial of smoke alarm functionality. Presence, functionality, features, and location of pre-existing smoke alarms were ascertained by staff observation and testing. Household and building descriptors were collected using questionnaires. Households were classified by presence of smoke alarms, functional alarms, and functional and properly mounted alarms placed in hallways and on each floor but not in recommended avoidance locations. Smoke alarms were present in 89%, and functional units in 78%, of households. Only 6-38% met all assessed functionality and placement recommendations. Homes frequently lacked alarms in any bedrooms or on each floor. Building age, but not renovation status, was associated with all dimensions of smoke alarm coverage; post-1980 constructions were 1.7 times more likely to comply with placement recommendations than were pre-1941 homes (95% CI: 1.1-2.6). Respondent education and race/ethnicity, children <5 years, residency duration, number of floors, wood stoves and fireplaces, number of smoke alarms, recency of smoke alarm testing, carbon monoxide monitors, and fire ladders displayed varying relationships with alarm presence, functionality, and placement. Strategies for maintaining smoke alarms in functional condition and improving compliance with placement recommendations are necessary to achieve universal coverage, and will benefit the majority of households.

  7. Comparison of Postoperative Respiratory Monitoring by Acoustic and Transthoracic Impedance Technologies in Pediatric Patients at Risk of Respiratory Depression.

    PubMed

    Patino, Mario; Kalin, Megan; Griffin, Allison; Minhajuddin, Abu; Ding, Lili; Williams, Timothy; Ishman, Stacey; Mahmoud, Mohamed; Kurth, C Dean; Szmuk, Peter

    2017-06-01

    In children, postoperative respiratory rate (RR) monitoring by transthoracic impedance (TI), capnography, and manual counting has limitations. The rainbow acoustic monitor (RAM) measures continuous RR noninvasively by a different methodology. Our primary aim was to compare the degree of agreement and accuracy of RR measurements as determined by RAM and TI to that of manual counting. Secondary aims include tolerance and analysis of alarm events. Sixty-two children (2-16 years old) were admitted after tonsillectomy or receiving postoperative patient/parental-controlled analgesia. RR was measured at regular intervals by RAM, TI, and manual count. Each TI or RAM alarm resulted in a clinical evaluation to categorize as a true or false alarm. To assess accuracy and degree of agreement of RR measured by RAM or TI compared with manual counting, a Bland-Altman analysis was utilized showing the average difference and the limits of agreement. Sensitivity and specificity of RR alarms by TI and RAM are presented. Fifty-eight posttonsillectomy children and 4 patient/parental-controlled analgesia users aged 6.5 ± 3.4 years and weighting 35.3 ± 22.7 kg (body mass index percentile 76.6 ± 30.8) were included. The average monitoring time per patient was 15.9 ± 4.8 hours. RAM was tolerated 87% of the total monitoring time. The manual RR count was significantly different from TI (P = .007) with an average difference ± SD of 1.39 ± 10.6 but were not significantly different from RAM (P = .81) with an average difference ± SD of 0.17 ± 6.8. The proportion of time when RR measurements differed by ≥4 breaths was 22% by TI and was 11% by RAM. Overall, 276 alarms were detected (mean alarms/patient = 4.5). The mean number of alarms per patient were 1.58 ± 2.49 and 2.87 ± 4.32 for RAM and TI, respectively. The mean number of false alarms was 0.18 ± 0.71 for RAM and 1.00 ± 2.78 for TI. The RAM was found to have 46.6% sensitivity (95% confidence interval [CI], 0.29-0.64), 95.9% specificity (95% CI, 0.90-1.00), 88.9% positive predictive value (95% CI, 0.73-1.00), and 72.1% negative predictive value (95% CI, 0.61-0.84), whereas the TI monitor had 68.5% sensitivity (95% CI, 0.53-0.84), 72.0% specificity (95% CI, 0.60-0.84), 59.0% positive (95% CI, 0.44-0.74), and 79.5% negative predictive value (95% CI, 0.69-0.90). In children at risk of postoperative respiratory depression, RR assessment by RAM was not different to manual counting. RAM was well tolerated, had a lower incidence of false alarms, and had better specificity and positive predictive value than TI. Rigorous evaluation of the negative predictive value is essential to determine the role of postoperative respiratory monitoring with RAM.

  8. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...

  9. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...

  10. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...

  11. Detection of cough signals in continuous audio recordings using hidden Markov models.

    PubMed

    Matos, Sergio; Birring, Surinder S; Pavord, Ian D; Evans, David H

    2006-06-01

    Cough is a common symptom of many respiratory diseases. The evaluation of its intensity and frequency of occurrence could provide valuable clinical information in the assessment of patients with chronic cough. In this paper we propose the use of hidden Markov models (HMMs) to automatically detect cough sounds from continuous ambulatory recordings. The recording system consists of a digital sound recorder and a microphone attached to the patient's chest. The recognition algorithm follows a keyword-spotting approach, with cough sounds representing the keywords. It was trained on 821 min selected from 10 ambulatory recordings, including 2473 manually labeled cough events, and tested on a database of nine recordings from separate patients with a total recording time of 3060 min and comprising 2155 cough events. The average detection rate was 82% at a false alarm rate of seven events/h, when considering only events above an energy threshold relative to each recording's average energy. These results suggest that HMMs can be applied to the detection of cough sounds from ambulatory patients. A postprocessing stage to perform a more detailed analysis on the detected events is under development, and could allow the rejection of some of the incorrectly detected events.

  12. Resilience in polar ecosystems: From drivers to impacts and changes

    NASA Astrophysics Data System (ADS)

    Bölter, Manfred; Müller, Felix

    2016-03-01

    The theory of resilience is increasing in applied ecosystem research and has become a valuable concept for analyzing relationships between natural environments and various stressors, e.g., global warming or direct human impacts. This concept offers opportunities to apply management strategies to different system levels and can provide insights into future ecosystem change. Polar systems are known to be ecologically sensitive to global and local impacts. Records of changes in polar environments, used as alarm signals by governmental and non-governmental institutions, are well documented in various reports. However, it remains difficult to define specific disturbance thresholds, only few methods allow an evaluation of the actual natural state of polar systems, its degree of modification they can accommodate before trophic systems change with severe damages. Some of the main drivers of system changes have been analyzed with respect to possible effects on system changes over different time scales. This paper reviews studies of polar ecosystems and their ability to cope with changes by assessing their resilience in response to human disturbances. Furthermore, we suggest that a customized framework (drivers, pressures, states, impacts, and responses (DPSIR)) should be applied to obtain an improved understanding of the interactions between the state of, and changes in, natural systems.

  13. A Dynamic Intrusion Detection System Based on Multivariate Hotelling's T2 Statistics Approach for Network Environments

    PubMed Central

    Avalappampatty Sivasamy, Aneetha; Sundan, Bose

    2015-01-01

    The ever expanding communication requirements in today's world demand extensive and efficient network systems with equally efficient and reliable security features integrated for safe, confident, and secured communication and data transfer. Providing effective security protocols for any network environment, therefore, assumes paramount importance. Attempts are made continuously for designing more efficient and dynamic network intrusion detection models. In this work, an approach based on Hotelling's T2 method, a multivariate statistical analysis technique, has been employed for intrusion detection, especially in network environments. Components such as preprocessing, multivariate statistical analysis, and attack detection have been incorporated in developing the multivariate Hotelling's T2 statistical model and necessary profiles have been generated based on the T-square distance metrics. With a threshold range obtained using the central limit theorem, observed traffic profiles have been classified either as normal or attack types. Performance of the model, as evaluated through validation and testing using KDD Cup'99 dataset, has shown very high detection rates for all classes with low false alarm rates. Accuracy of the model presented in this work, in comparison with the existing models, has been found to be much better. PMID:26357668

  14. A Dynamic Intrusion Detection System Based on Multivariate Hotelling's T2 Statistics Approach for Network Environments.

    PubMed

    Sivasamy, Aneetha Avalappampatty; Sundan, Bose

    2015-01-01

    The ever expanding communication requirements in today's world demand extensive and efficient network systems with equally efficient and reliable security features integrated for safe, confident, and secured communication and data transfer. Providing effective security protocols for any network environment, therefore, assumes paramount importance. Attempts are made continuously for designing more efficient and dynamic network intrusion detection models. In this work, an approach based on Hotelling's T(2) method, a multivariate statistical analysis technique, has been employed for intrusion detection, especially in network environments. Components such as preprocessing, multivariate statistical analysis, and attack detection have been incorporated in developing the multivariate Hotelling's T(2) statistical model and necessary profiles have been generated based on the T-square distance metrics. With a threshold range obtained using the central limit theorem, observed traffic profiles have been classified either as normal or attack types. Performance of the model, as evaluated through validation and testing using KDD Cup'99 dataset, has shown very high detection rates for all classes with low false alarm rates. Accuracy of the model presented in this work, in comparison with the existing models, has been found to be much better.

  15. Flood Warning and Forecasting System in Slovakia

    NASA Astrophysics Data System (ADS)

    Leskova, Danica

    2016-04-01

    In 2015, it finished project Flood Warning and Forecasting System (POVAPSYS) as part of the flood protection in Slovakia till 2010. The aim was to build POVAPSYS integrated computerized flood forecasting and warning system. It took a qualitatively higher level of output meteorological and hydrological services in case of floods affecting large territorial units, as well as local flood events. It is further unfolding demands on performance and coordination of meteorological and hydrological services, troubleshooting observation, evaluation of data, fast communication, modeling and forecasting of meteorological and hydrological processes. Integration of all information entering and exiting to and from the project POVAPSYS provides Hydrological Flood Forecasting System (HYPOS). The system provides information on the current hydrometeorological situation and its evolution with the generation of alerts and notifications in case of exceeding predefined thresholds. HYPOS's functioning of the system requires flawless operability in critical situations while minimizing the loss of its key parts. HYPOS is a core part of the project POVAPSYS, it is a comprehensive software solutions based on a modular principle, providing data and processed information including alarms, in real time. In order to achieve full functionality of the system, in proposal, we have put emphasis on reliability, robustness, availability and security.

  16. Building Intrusion Detection with a Wireless Sensor Network

    NASA Astrophysics Data System (ADS)

    Wälchli, Markus; Braun, Torsten

    This paper addresses the detection and reporting of abnormal building access with a wireless sensor network. A common office room, offering space for two working persons, has been monitored with ten sensor nodes and a base station. The task of the system is to report suspicious office occupation such as office searching by thieves. On the other hand, normal office occupation should not throw alarms. In order to save energy for communication, the system provides all nodes with some adaptive short-term memory. Thus, a set of sensor activation patterns can be temporarily learned. The local memory is implemented as an Adaptive Resonance Theory (ART) neural network. Unknown event patterns detected on sensor node level are reported to the base station, where the system-wide anomaly detection is performed. The anomaly detector is lightweight and completely self-learning. The system can be run autonomously or it could be used as a triggering system to turn on an additional high-resolution system on demand. Our building monitoring system has proven to work reliably in different evaluated scenarios. Communication costs of up to 90% could be saved compared to a threshold-based approach without local memory.

  17. Monitoring and Acquisition Real-time System (MARS)

    NASA Technical Reports Server (NTRS)

    Holland, Corbin

    2013-01-01

    MARS is a graphical user interface (GUI) written in MATLAB and Java, allowing the user to configure and control the Scalable Parallel Architecture for Real-Time Acquisition and Analysis (SPARTAA) data acquisition system. SPARTAA not only acquires data, but also allows for complex algorithms to be applied to the acquired data in real time. The MARS client allows the user to set up and configure all settings regarding the data channels attached to the system, as well as have complete control over starting and stopping data acquisition. It provides a unique "Test" programming environment, allowing the user to create tests consisting of a series of alarms, each of which contains any number of data channels. Each alarm is configured with a particular algorithm, determining the type of processing that will be applied on each data channel and tested against a defined threshold. Tests can be uploaded to SPARTAA, thereby teaching it how to process the data. The uniqueness of MARS is in its capability to be adaptable easily to many test configurations. MARS sends and receives protocols via TCP/IP, which allows for quick integration into almost any test environment. The use of MATLAB and Java as the programming languages allows for developers to integrate the software across multiple operating platforms.

  18. Method for detecting and avoiding flight hazards

    NASA Astrophysics Data System (ADS)

    von Viebahn, Harro; Schiefele, Jens

    1997-06-01

    Today's aircraft equipment comprise several independent warning and hazard avoidance systems like GPWS, TCAS or weather radar. It is the pilot's task to monitor all these systems and take the appropriate action in case of an emerging hazardous situation. The developed method for detecting and avoiding flight hazards combines all potential external threats for an aircraft into a single system. It is based on an aircraft surrounding airspace model consisting of discrete volume elements. For each element of the volume the threat probability is derived or computed from sensor output, databases, or information provided via datalink. The position of the own aircraft is predicted by utilizing a probability distribution. This approach ensures that all potential positions of the aircraft within the near future are considered while weighting the most likely flight path. A conflict detection algorithm initiates an alarm in case the threat probability exceeds a threshold. An escape manoeuvre is generated taking into account all potential hazards in the vicinity, not only the one which caused the alarm. The pilot gets a visual information about the type, the locating, and severeness o the threat. The algorithm was implemented and tested in a flight simulator environment. The current version comprises traffic, terrain and obstacle hazards avoidance functions. Its general formulation allows an easy integration of e.g. weather information or airspace restrictions.

  19. Protect Your Health as You Grow Older

    MedlinePlus

    ... smoke alarms if possible. These alarms use lithium batteries and last longer than regular smoke alarms. They ... If you use regular smoke alarms, replace the batteries every year. (Tip: Change smoke alarm batteries when ...

  20. Smoke alarm and battery function 42 months after installation: a randomized trial.

    PubMed

    Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Jones, Michael P; Young, Tracy; Zwerling, Craig

    2010-10-01

    This randomized trial presents findings from the longest follow-up study of smoke alarm and battery function to date. The purpose of this study is to examine differences in long-term function of smoke alarm and battery combinations. A total of 691 households in an ongoing cohort study were randomly allocated into smoke alarm groups of ionizing and photoelectric and battery groups of zinc and lithium. Smoke alarm function was measured in 633 (91.6%) households from January 2007 through February 2008, 42 months following original smoke alarm/battery installation. Data analyses were conducted in 2009. After 3.5 years, 81.9% of the 1898 smoke alarms were functional. Ionizing alarms with zinc batteries were the least likely to function (72.7%). In comparison, photoelectric alarms with lithium batteries were 2.9 times (95% CI=1.8, 4.5) more likely to function; ionizing alarms with lithium batteries were 2.0 times (95% CI=1.3, 3.1) more likely to function; and photoelectric alarms with zinc batteries were 1.7 times (95% CI=1.1, 2.5) more likely to function. Functionality was strongly tied to number of reports of nuisance alarms, which was higher for ionizing than photoelectric alarms. Photoelectric smoke alarms and lithium batteries are the most likely to function long after smoke alarm installation, and may be worthwhile investments despite their increased cost. Copyright © 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Reducing Alarm Fatigue in Two Neonatal Intensive Care Units through a Quality Improvement Collaboration.

    PubMed

    Johnson, Kendall R; Hagadorn, James I; Sink, David W

    2018-05-21

     To reduce nonactionable oximeter alarms by 80% without increasing time infants were hypoxemic (oxygen saturation [SpO 2 ] ≤ 80%) or hyperoxemic (SpO 2  > 95% while on supplemental oxygen).  In 2015, a multidisciplinary team at Connecticut Children's Medical Center initiated a quality improvement project to reduce nonactionable oximeter alarms in two referral neonatal intensive care units (NICUs). Changes made through improvement cycles included reduction of the low oximeter alarm limit for specific populations, increased low alarm delay, development of postmenstrual age-based alarm profiles, and updated bedside visual reminders. Manual alarm tallies and electronic SpO 2 data were collected throughout the project.  Alarm tallies were collected for 158 patient care hours with SpO 2 data available for 138 of those hours. Mean number of total nonactionable alarms per patient per hour decreased from 9 to 2 (78% decrease) and the mean number of nonactionable low alarms per patient per hour decreased from 5 to 1 (80% decrease). No change was noted in the balancing measures of percentage time with SpO 2  ≤ 80% (mean 4.3%) or SpO 2  > 95% (mean 23.7%).  Through small changes in oximeter alarm settings, including revision of alarm limits, alarm delays, and age-specific alarm profiles, our NICUs significantly reduced nonactionable alarms without increasing hypoxemia. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Prevalence of working smoke alarms in local authority inner city housing: randomised controlled trial

    PubMed Central

    Rowland, Diane; DiGuiseppi, Carolyn; Roberts, Ian; Curtis, Katherine; Roberts, Helen; Ginnelly, Laura; Sculpher, Mark; Wade, Angela

    2002-01-01

    Objectives To identify which type of smoke alarm is most likely to remain working in local authority inner city housing, and to identify an alarm tolerated in households with smokers. Design Randomised controlled trial. Setting Two local authority housing estates in inner London. Participants 2145 households. Intervention Installation of one of five types of smoke alarm (ionisation sensor with a zinc battery; ionisation sensor with a zinc battery and pause button; ionisation sensor with a lithium battery and pause button; optical sensor with a lithium battery; or optical sensor with a zinc battery). Main outcome measure Percentage of homes with any working alarm and percentage in which the alarm installed for this study was working after 15 months. Results 54.4% (1166/2145) of all households and 45.9% (465/1012) of households occupied by smokers had a working smoke alarm. Ionisation sensor, lithium battery, and there being a smoker in the household were independently associated with whether an alarm was working (adjusted odds ratios 2.24 (95% confidence interval 1.75 to 2.87), 2.20 (1.77 to 2.75), and 0.62 (0.52 to 0.74)). The most common reasons for non-function were missing battery (19%), missing alarm (17%), and battery disconnected (4%). Conclusions Nearly half of the alarms installed were not working when tested 15 months later. Type of alarm and power source are important determinants of whether a household had a working alarm. What is already known on this topicFunctioning smoke alarms can reduce the risk of death in the event of a house fireMany local authorities install smoke alarms in their propertiesSeveral different types of smoke alarm are availableWhat this study addsOnly half of the smoke alarms installed in local authority housing were still working 15 months laterIonising smoke alarms with long life lithium batteries were most likely to remain functioningInstalling smoke alarms may not be an effective use of resources PMID:12411356

  3. Alarm setting for the critically ill patient: a descriptive pilot survey of nurses' perceptions of current practice in an Australian Regional Critical Care Unit.

    PubMed

    Christensen, Martin; Dodds, Andrew; Sauer, Josh; Watts, Nigel

    2014-08-01

    The aim of this survey was to assess registered nurse's perceptions of alarm setting and management in an Australian Regional Critical Care Unit. The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms. This study contributes to what is known about alarm fatigue, setting and management within a critical care environment. In addition it gives an insight as to what nurses' within a regional context consider the key factors which contribute to alarm fatigue. Clearly nursing burnout and potential patient harm are important considerations for practice especially when confronted with alarm fatigue and desensitisation. Therefore, promoting and maintaining an environment of ongoing intra-professional communication and alarm surveillance are crucial in alleviating these potential problems. Copyright © 2014. Published by Elsevier Ltd.

  4. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  5. Explosive hazard detection using MIMO forward-looking ground penetrating radar

    NASA Astrophysics Data System (ADS)

    Shaw, Darren; Ho, K. C.; Stone, Kevin; Keller, James M.; Popescu, Mihail; Anderson, Derek T.; Luke, Robert H.; Burns, Brian

    2015-05-01

    This paper proposes a machine learning algorithm for subsurface object detection on multiple-input-multiple-output (MIMO) forward-looking ground-penetrating radar (FLGPR). By detecting hazards using FLGPR, standoff distances of up to tens of meters can be acquired, but this is at the degradation of performance due to high false alarm rates. The proposed system utilizes an anomaly detection prescreener to identify potential object locations. Alarm locations have multiple one-dimensional (ML) spectral features, two-dimensional (2D) spectral features, and log-Gabor statistic features extracted. The ability of these features to reduce the number of false alarms and increase the probability of detection is evaluated for both co-polarizations present in the Akela MIMO array. Classification is performed by a Support Vector Machine (SVM) with lane-based cross-validation for training and testing. Class imbalance and optimized SVM kernel parameters are considered during classifier training.

  6. Decision-level fusion of SAR and IR sensor information for automatic target detection

    NASA Astrophysics Data System (ADS)

    Cho, Young-Rae; Yim, Sung-Hyuk; Cho, Hyun-Woong; Won, Jin-Ju; Song, Woo-Jin; Kim, So-Hyeon

    2017-05-01

    We propose a decision-level architecture that combines synthetic aperture radar (SAR) and an infrared (IR) sensor for automatic target detection. We present a new size-based feature, called target-silhouette to reduce the number of false alarms produced by the conventional target-detection algorithm. Boolean Map Visual Theory is used to combine a pair of SAR and IR images to generate the target-enhanced map. Then basic belief assignment is used to transform this map into a belief map. The detection results of sensors are combined to build the target-silhouette map. We integrate the fusion mass and the target-silhouette map on the decision level to exclude false alarms. The proposed algorithm is evaluated using a SAR and IR synthetic database generated by SE-WORKBENCH simulator, and compared with conventional algorithms. The proposed fusion scheme achieves higher detection rate and lower false alarm rate than the conventional algorithms.

  7. Defining hazards of supplemental oxygen therapy in neonatology using the FMEA tool.

    PubMed

    van der Eijk, Anne Catherine; Rook, Denise; Dankelman, Jenny; Smit, Bert Johan

    2013-01-01

    To prospectively evaluate hazards in the process of supplemental oxygen therapy in very preterm infants hospitalized in a Dutch NICU. A Failure Mode and Effects Analysis (FMEA) was conducted by a multidisciplinary team. This team identified, evaluated, and prioritized hazards of supplemental oxygen therapy in preterm infants. After accrediting "hazard scores" for each step in this process, recommendations were formulated for the main hazards. Performing the FMEA took seven meetings of 2 hours. The top 10 hazards could all be categorized into three main topics: incorrect adjustment of the fraction of inspired oxygen (FiO2), incorrect alarm limits for SpO2, and incorrect pulse-oximetry alarm limits on patient monitors for temporary use. The FMEA culminated in recommendations in both educational and technical directions. These included suggestions for (changes in) protocols on alarm limits and manual FiO2 adjustments, education of NICU staff on hazards of supplemental oxygen, and technical improvements in respiratory devices and patient monitors. The FMEA prioritized flaws in the process of supplemental oxygen therapy in very preterm infants. Thanks to the structured approach of the analysis by a multidisciplinary team, several recommendations were made. These recommendations are currently implemented in the study's center.

  8. A Knowledge-Based Approach to Automatic Detection of Equipment Alarm Sounds in a Neonatal Intensive Care Unit Environment.

    PubMed

    Raboshchuk, Ganna; Nadeu, Climent; Jancovic, Peter; Lilja, Alex Peiro; Kokuer, Munevver; Munoz Mahamud, Blanca; Riverola De Veciana, Ana

    2018-01-01

    A large number of alarm sounds triggered by biomedical equipment occur frequently in the noisy environment of a neonatal intensive care unit (NICU) and play a key role in providing healthcare. In this paper, our work on the development of an automatic system for detection of acoustic alarms in that difficult environment is presented. Such automatic detection system is needed for the investigation of how a preterm infant reacts to auditory stimuli of the NICU environment and for an improved real-time patient monitoring. The approach presented in this paper consists of using the available knowledge about each alarm class in the design of the detection system. The information about the frequency structure is used in the feature extraction stage, and the time structure knowledge is incorporated at the post-processing stage. Several alternative methods are compared for feature extraction, modeling, and post-processing. The detection performance is evaluated with real data recorded in the NICU of the hospital, and by using both frame-level and period-level metrics. The experimental results show that the inclusion of both spectral and temporal information allows to improve the baseline detection performance by more than 60%.

  9. A Knowledge-Based Approach to Automatic Detection of Equipment Alarm Sounds in a Neonatal Intensive Care Unit Environment

    PubMed Central

    Nadeu, Climent; Jančovič, Peter; Lilja, Alex Peiró; Köküer, Münevver; Muñoz Mahamud, Blanca; Riverola De Veciana, Ana

    2018-01-01

    A large number of alarm sounds triggered by biomedical equipment occur frequently in the noisy environment of a neonatal intensive care unit (NICU) and play a key role in providing healthcare. In this paper, our work on the development of an automatic system for detection of acoustic alarms in that difficult environment is presented. Such automatic detection system is needed for the investigation of how a preterm infant reacts to auditory stimuli of the NICU environment and for an improved real-time patient monitoring. The approach presented in this paper consists of using the available knowledge about each alarm class in the design of the detection system. The information about the frequency structure is used in the feature extraction stage, and the time structure knowledge is incorporated at the post-processing stage. Several alternative methods are compared for feature extraction, modeling, and post-processing. The detection performance is evaluated with real data recorded in the NICU of the hospital, and by using both frame-level and period-level metrics. The experimental results show that the inclusion of both spectral and temporal information allows to improve the baseline detection performance by more than 60%. PMID:29404227

  10. Carbon Monoxide Alarm and Smoke Alarm Use Among Parents Recruited From a Pediatric Emergency Department.

    PubMed

    Roberts, Kristin J; Fowler, Erica; Comstock, R Dawn; Fernandez, Soledad; Abdel-Rasoul, Mahmoud; Mihalov, Leslie; Casavant, Marcel J; McKenzie, Lara B

    2018-02-01

    Although the proper installation and maintenance of carbon monoxide (CO) and smoke alarms can protect individuals from residential CO-related and fire-related injuries, these devices are underutilized. We describe characteristics associated with self-reported CO and smoke alarm use of parents recruited from a pediatric emergency department to improve CO alarm use. Parents of children ≤ 18 years (N = 299) reported socio-demographic characteristics and CO and smoke alarm ownership and practices. We assigned participants to a behavioral profile and a Precaution Adoption Process Model stage based on their self-reported CO and smoke alarm use. Most participants (71%) did not have CO alarms in their homes, but reported owning at least one working smoke alarm (98%). Participants who reported "perfect" CO alarm behavior (defined as having a working CO alarm, one near a sleeping area, with batteries replaced every 6 months; 9%) were more likely to earn a higher income, own their home, and have lived at their current residence for at least 2 years. Participants who reported "perfect" smoke alarm behavior (defined as having a working smoke alarm on every level, with batteries replaced every 6 months; 49%) were more likely to rent their home, receive federal assistance, and have lived at their current residence for at least 2 years. Interventions to increase correct CO alarm use are necessary.

  11. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring.

    PubMed

    Kovatchev, Boris P; Patek, Stephen D; Ortiz, Edward Andrew; Breton, Marc D

    2015-03-01

    The level of continuous glucose monitoring (CGM) accuracy needed for insulin dosing using sensor values (i.e., the level of accuracy permitting non-adjunct CGM use) is a topic of ongoing debate. Assessment of this level in clinical experiments is virtually impossible because the magnitude of CGM errors cannot be manipulated and related prospectively to clinical outcomes. A combination of archival data (parallel CGM, insulin pump, self-monitoring of blood glucose [SMBG] records, and meals for 56 pump users with type 1 diabetes) and in silico experiments was used to "replay" real-life treatment scenarios and relate sensor error to glycemic outcomes. Nominal blood glucose (BG) traces were extracted using a mathematical model, yielding 2,082 BG segments each initiated by insulin bolus and confirmed by SMBG. These segments were replayed at seven sensor accuracy levels (mean absolute relative differences [MARDs] of 3-22%) testing six scenarios: insulin dosing using sensor values, threshold, and predictive alarms, each without or with considering CGM trend arrows. In all six scenarios, the occurrence of hypoglycemia (frequency of BG levels ≤50 mg/dL and BG levels ≤39 mg/dL) increased with sensor error, displaying an abrupt slope change at MARD =10%. Similarly, hyperglycemia (frequency of BG levels ≥250 mg/dL and BG levels ≥400 mg/dL) increased and displayed an abrupt slope change at MARD=10%. When added to insulin dosing decisions, information from CGM trend arrows, threshold, and predictive alarms resulted in improvement in average glycemia by 1.86, 8.17, and 8.88 mg/dL, respectively. Using CGM for insulin dosing decisions is feasible below a certain level of sensor error, estimated in silico at MARD=10%. In our experiments, further accuracy improvement did not contribute substantively to better glycemic outcomes.

  12. Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring

    PubMed Central

    Patek, Stephen D.; Ortiz, Edward Andrew; Breton, Marc D.

    2015-01-01

    Abstract Background: The level of continuous glucose monitoring (CGM) accuracy needed for insulin dosing using sensor values (i.e., the level of accuracy permitting non-adjunct CGM use) is a topic of ongoing debate. Assessment of this level in clinical experiments is virtually impossible because the magnitude of CGM errors cannot be manipulated and related prospectively to clinical outcomes. Materials and Methods: A combination of archival data (parallel CGM, insulin pump, self-monitoring of blood glucose [SMBG] records, and meals for 56 pump users with type 1 diabetes) and in silico experiments was used to “replay” real-life treatment scenarios and relate sensor error to glycemic outcomes. Nominal blood glucose (BG) traces were extracted using a mathematical model, yielding 2,082 BG segments each initiated by insulin bolus and confirmed by SMBG. These segments were replayed at seven sensor accuracy levels (mean absolute relative differences [MARDs] of 3–22%) testing six scenarios: insulin dosing using sensor values, threshold, and predictive alarms, each without or with considering CGM trend arrows. Results: In all six scenarios, the occurrence of hypoglycemia (frequency of BG levels ≤50 mg/dL and BG levels ≤39 mg/dL) increased with sensor error, displaying an abrupt slope change at MARD =10%. Similarly, hyperglycemia (frequency of BG levels ≥250 mg/dL and BG levels ≥400 mg/dL) increased and displayed an abrupt slope change at MARD=10%. When added to insulin dosing decisions, information from CGM trend arrows, threshold, and predictive alarms resulted in improvement in average glycemia by 1.86, 8.17, and 8.88 mg/dL, respectively. Conclusions: Using CGM for insulin dosing decisions is feasible below a certain level of sensor error, estimated in silico at MARD=10%. In our experiments, further accuracy improvement did not contribute substantively to better glycemic outcomes. PMID:25436913

  13. 46 CFR 113.43-3 - Alarm system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...

  14. 46 CFR 113.43-3 - Alarm system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...

  15. 46 CFR 113.43-3 - Alarm system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Alarm system. 113.43-3 Section 113.43-3 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-3 Alarm system. (a) Each vessel must have a steering failure alarm system that actuates an audible and visible alarm in the pilothouse when the actual...

  16. Increasing smoke alarm operability through theory-based health education: a randomised trial

    PubMed Central

    Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S

    2015-01-01

    Background Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Methods Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm’s hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005–2008. Followup visits checked alarm operability in 370 homes (85%) 1–3.5 years after installation. Main outcome measures: number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Results Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Conclusions Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. Trial registration number http://www.clinicaltrials.gov number NCT00139126. PMID:25165090

  17. Evaluation of ventilators for mouthpiece ventilation in neuromuscular disease.

    PubMed

    Khirani, Sonia; Ramirez, Adriana; Delord, Vincent; Leroux, Karl; Lofaso, Frédéric; Hautot, Solène; Toussaint, Michel; Orlikowski, David; Louis, Bruno; Fauroux, Brigitte

    2014-09-01

    Daytime mouthpiece ventilation is a useful adjunct to nocturnal noninvasive ventilation (NIV) in patients with neuromuscular disease. The aims of the study were to analyze the practice of mouthpiece ventilation and to evaluate the performance of ventilators for mouthpiece ventilation. Practice of mouthpiece ventilation was assessed by a questionnaire, and the performance of 6 home ventilators with mouthpiece ventilation was assessed in a bench test using 24 different conditions per ventilator: 3 mouthpieces, a child and an adult patient profile, and 4 ventilatory modes. Questionnaires were obtained from 30 subjects (mean age 33 ± 11 y) using NIV for 12 ± 7 y. Fifteen subjects used NIV for > 20 h/day, and 11 were totally ventilator-dependent. The subject-reported benefits of mouthpiece ventilation were a reduction in dyspnea (73%) and fatigue (93%) and an improvement in speech (43%) and eating (27%). The bench study showed that none of the ventilators, even those with mouthpiece ventilation software, were able to deliver mouthpiece ventilation without alarms and/or autotriggering in each condition. Alarms and/or ineffective triggering or autotriggering were observed in 135 of the 198 conditions. The occurrence of alarms was more common with a large mouthpiece without a filter compared to a small mouthpiece with a filter (P < .001), but it was not related to the patient profile, the ventilatory mode, or the type of ventilator. Subjects are satisfied with mouthpiece ventilation. Alarms are common with home ventilators, although less common in those with mouthpiece ventilation software. Improvements in home ventilators are needed to facilitate the expansion of mouthpiece ventilation. Copyright © 2014 by Daedalus Enterprises.

  18. Attempted early detection of influenza A (H1N1) pandemic with surveillance data of influenza‐like illness and unexplained pneumonia

    PubMed Central

    Qian, Yan‐Hua; Su, Jing; Shi, Ping; He, En‐Qi; Shao, Jie; Sun, Na; Zu, Rong‐Qiang; Yu, Rong‐Bin

    2011-01-01

    Please cite this paper as: Qian et al. (2011) Attempted early detection of influenza A (H1N1) pandemic with surveillance data of influenza‐like illness and unexplained pneumonia. Influenza and Other Respiratory Viruses 5(6), e479–e486. Background  To collect disease information and provide data for early detection of epidemics, two surveillance systems were established for influenza‐like illness (ILI) and unexplained pneumonia (UP) in Wuxi, People’s Republic of China. Objectives  The current study aims to describe the performance of these surveillance systems during 2004–2009 and to evaluate the value of surveillance data in detection of influenza epidemics. Methods  Two national ILI sentinel hospitals and three UP sentinel hospitals provided data to the surveillance systems. The surveillance data from hospital‐based outpatient clinics and emergency rooms were compared by year. The ILI data of 2009 were further modeled based on previous data using both a control chart method and a moving average regression method. Alarms of potential epidemics would be raised when the input surveillance data surpassed a threshold. Results  In 2009, the proportions of ILI and respiratory illness with fever (one surveillance syndrome of the UP system) to total patient visits (3·40% and 11·76%, respectively) were higher than the previous years. The surveillance data of both systems also showed developing trends similar to the influenza A (H1N1) pandemic in 2009. When the surveillance data of 2009 were fitted in the two detection models, alarms were produced on the occurrence of the first local case of influenza A (H1N1), outbreaks in schools and in general populations. Conclusions  The results indicated the potential for using ILI and UP surveillance data as syndromic indicators to detect and provide an early warning for influenza epidemics. PMID:21668678

  19. Trust and the Compliance-Reliance Paradigm: The Effects of Risk, Error Bias, and Reliability on Trust and Dependence.

    PubMed

    Chancey, Eric T; Bliss, James P; Yamani, Yusuke; Handley, Holly A H

    2017-05-01

    This study provides a theoretical link between trust and the compliance-reliance paradigm. We propose that for trust mediation to occur, the operator must be presented with a salient choice, and there must be an element of risk for dependence. Research suggests that false alarms and misses affect dependence via two independent processes, hypothesized as trust in signals and trust in nonsignals. These two trust types manifest in categorically different behaviors: compliance and reliance. Eighty-eight participants completed a primary flight task and a secondary signaling system task. Participants evaluated their trust according to the informational bases of trust: performance, process, and purpose. Participants were in a high- or low-risk group. Signaling systems varied by reliability (90%, 60%) within subjects and error bias (false alarm prone, miss prone) between subjects. False-alarm rate affected compliance but not reliance. Miss rate affected reliance but not compliance. Mediation analyses indicated that trust mediated the relationship between false-alarm rate and compliance. Bayesian mediation analyses favored evidence indicating trust did not mediate miss rate and reliance. Conditional indirect effects indicated that factors of trust mediated the relationship between false-alarm rate and compliance (i.e., purpose) and reliance (i.e., process) but only in the high-risk group. The compliance-reliance paradigm is not the reflection of two types of trust. This research could be used to update training and design recommendations that are based upon the assumption that trust causes operator responses regardless of error bias.

  20. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2014-10-01 2014-10-01 false Location and spacing of manual alarm boxes. 76.35-10...

  1. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2013-10-01 2013-10-01 false Location and spacing of manual alarm boxes. 76.35-10...

  2. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2011-10-01 2011-10-01 false Location and spacing of manual alarm boxes. 76.35-10...

  3. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2012-10-01 2012-10-01 false Location and spacing of manual alarm boxes. 76.35-10...

  4. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in main... 46 Shipping 3 2010-10-01 2010-10-01 false Location and spacing of manual alarm boxes. 76.35-10...

  5. The perceived urgency of auditory warning alarms used in the hospital operating room is inappropriate.

    PubMed

    Mondor, Todd A; Finley, G Allen

    2003-03-01

    To examine the perceived urgency of 13 auditory warning alarms commonly occurring in the hospital operating room. Undergraduate students, who were naïve with respect to the clinical situation associated with the alarms, judged perceived urgency of each alarm on a ten-point scale. The perceived urgency of the alarms was not consistent with the actual urgency of the clinical situation that triggers it. In addition, those alarms indicating patient condition were generally perceived as less urgent than those alarms indicating the operation of equipment. Of particular interest were three sets of alarms designed by equipment manufacturers to indicate specific priorities for action. Listeners did not perceive any differences in the urgency of the 'information only', 'medium' and 'high' priority alarms of two of the monitors with all judged as low to moderate in urgency. In contrast, the high priority alarm of the third monitor was judged as significantly more urgent than its low and medium urgency counterparts. The alarms currently in use do not convey the intended sense of urgency to naïve listeners, and this holds even for two sets of alarms designed specifically by manufacturers to convey different levels of urgency.

  6. Increasing smoke alarm operability through theory-based health education: a randomised trial.

    PubMed

    Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S

    2014-12-01

    Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm's hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005-2008. Follow-up visits checked alarm operability in 370 homes (85%) 1-3.5 years after installation. number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. http://www.clinicaltrials.gov number NCT00139126. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Predicting potentially toxigenic Pseudo-nitzschia blooms in the Chesapeake Bay

    USGS Publications Warehouse

    Anderson, C.R.; Sapiano, M.R.P.; Prasad, M.B.K.; Long, W.; Tango, P.J.; Brown, C.W.; Murtugudde, R.

    2010-01-01

    Harmful algal blooms are now recognized as a significant threat to the Chesapeake Bay as they can severely compromise the economic viability of important recreational and commercial fisheries in the largest estuary of the United States. This study describes the development of empirical models for the potentially domoic acid-producing Pseudo-nitzschia species complex present in the Bay, developed from a 22-year time series of cell abundance and concurrent measurements of hydrographic and chemical properties. Using a logistic Generalized Linear Model (GLM) approach, model parameters and performance were compared over a range of Pseudo-nitzschia bloom thresholds relevant to toxin production by different species. Small-threshold blooms (???10cellsmL-1) are explained by time of year, location, and variability in surface values of phosphate, temperature, nitrate plus nitrite, and freshwater discharge. Medium- (100cellsmL-1) to large- threshold (1000cellsmL-1) blooms are further explained by salinity, silicic acid, dissolved organic carbon, and light attenuation (Secchi) depth. These predictors are similar to other models for Pseudo-nitzschia blooms on the west coast, suggesting commonalities across ecosystems. Hindcasts of bloom probabilities at a 19% bloom prediction point yield a Heidke Skill Score of -53%, a Probability of Detection ~75%, a False Alarm Ratio of ~52%, and a Probability of False Detection ~9%. The implication of possible future changes in Baywide nutrient stoichiometry on Pseudo-nitzschia blooms is discussed. ?? 2010 Elsevier B.V.

  8. Minimal olfactory perception during sleep: why odor alarms will not work for humans.

    PubMed

    Carskadon, Mary A; Herz, Rachel S

    2004-05-01

    To examine olfactory arousal threshold during sleep in comparison to an auditory tone. On night 1, participants rated odor intensity when awake and experienced olfactory stimuli during stage 1 sleep. Night 2 involved stage 2, stage 4, and rapid-eye-movement (REM) sleep trials using the "staircase" threshold-detection method. Electroencephalogram, electrooculogram, electromyogram, electrocardiogram, and respiration were recorded along with behavioral response. An 800-Hz tone was given on trials when odors failed to arouse. Participants slept in individual rooms. Stimulus-delivery systems were operated from a separate room, where an experimenter observed physiologic recordings and behavioral responses. Three healthy men and 3 women aged 20 to 25 years (mean, 22 years). Two odorants, peppermint and pyridine, at 4 concentrations were presented through nasal cannulas using an air-dilution olfactometer. Tones were played over a speaker. Behavioral (button press and oral) responses, electroencephalographic activation, and changes in breathing and heart rate were assessed. Participants responded to odors on 92% of stage 1 sleep trials. Peppermint was ineffective in stages 2, 4, and REM sleep. Pyridine produced behavioral threshold on 45% of stage 2 trials, none in stage 4, and one third of REM sleep trials. Tones were effective on at least 75% of trials. Heart rate increased significantly only following behavioral responses to odors or tones across sleep stages. The data indicate that human olfaction is not reliably capable of alerting a sleeper.

  9. Performance of the Species-Typical Alarm Response in Young Workers of the Ant Myrmica sabuleti (Hymenoptera: Formicidae) Is Induced by Interactions with Mature Workers

    PubMed Central

    Cammaerts, Marie-Claire

    2014-01-01

    Abstract Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants’ ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. PMID:25525102

  10. Patient characteristics associated with false arrhythmia alarms in intensive care.

    PubMed

    Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao

    2017-01-01

    A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients' annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years ( P =0.013; P =0.034), confused mental status ( P <0.001 for both comparisons), cardiovascular diagnoses ( P <0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) ( P =0.003; P =0.004) or ventricular paced rhythm ( P =0.002 for both comparisons), respiratory diagnoses ( P =0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones ( P <0.001 for both comparisons). Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management.

  11. Dual sensitivity mode system for monitoring processes and sensors

    DOEpatents

    Wilks, Alan D.; Wegerich, Stephan W.; Gross, Kenneth C.

    2000-01-01

    A method and system for analyzing a source of data. The system and method involves initially training a system using a selected data signal, calculating at least two levels of sensitivity using a pattern recognition methodology, activating a first mode of alarm sensitivity to monitor the data source, activating a second mode of alarm sensitivity to monitor the data source and generating a first alarm signal upon the first mode of sensitivity detecting an alarm condition and a second alarm signal upon the second mode of sensitivity detecting an associated alarm condition. The first alarm condition and second alarm condition can be acted upon by an operator and/or analyzed by a specialist or computer program.

  12. Thresholds for Coral Bleaching: Are Synergistic Factors and Shifting Thresholds Changing the Landscape for Management? (Invited)

    NASA Astrophysics Data System (ADS)

    Eakin, C.; Donner, S. D.; Logan, C. A.; Gledhill, D. K.; Liu, G.; Heron, S. F.; Christensen, T.; Rauenzahn, J.; Morgan, J.; Parker, B. A.; Hoegh-Guldberg, O.; Skirving, W. J.; Strong, A. E.

    2010-12-01

    As carbon dioxide rises in the atmosphere, climate change and ocean acidification are modifying important physical and chemical parameters in the oceans with resulting impacts on coral reef ecosystems. Rising CO2 is warming the world’s oceans and causing corals to bleach, with both alarming frequency and severity. The frequent return of stressful temperatures has already resulted in major damage to many of the world’s coral reefs and is expected to continue in the foreseeable future. Warmer oceans also have contributed to a rise in coral infectious diseases. Both bleaching and infectious disease can result in coral mortality and threaten one of the most diverse ecosystems on Earth and the important ecosystem services they provide. Additionally, ocean acidification from rising CO2 is reducing the availability of carbonate ions needed by corals to build their skeletons and perhaps depressing the threshold for bleaching. While thresholds vary among species and locations, it is clear that corals around the world are already experiencing anomalous temperatures that are too high, too often, and that warming is exceeding the rate at which corals can adapt. This is despite a complex adaptive capacity that involves both the coral host and the zooxanthellae, including changes in the relative abundance of the latter in their coral hosts. The safe upper limit for atmospheric CO2 is probably somewhere below 350ppm, a level we passed decades ago, and for temperature is a sustained global temperature increase of less than 1.5°C above pre-industrial levels. How much can corals acclimate and/or adapt to the unprecedented fast changing environmental conditions? Any change in the threshold for coral bleaching as the result of acclimation and/or adaption may help corals to survive in the future but adaptation to one stress may be maladaptive to another. There also is evidence that ocean acidification and nutrient enrichment modify this threshold. What do shifting thresholds mean for identifying limits and taking management actions to adapt to climate change?

  13. Predicting Vasovagal Syncope from Heart Rate and Blood Pressure: A Prospective Study in 140 Subjects.

    PubMed

    Virag, Nathalie; Erickson, Mark; Taraborrelli, Patricia; Vetter, Rolf; Lim, Phang Boon; Sutton, Richard

    2018-04-28

    We developed a vasovagal syncope (VVS) prediction algorithm for use during head-up tilt with simultaneous analysis of heart rate (HR) and systolic blood pressure (SBP). We previously tested this algorithm retrospectively in 1155 subjects, showing sensitivity 95%, specificity 93% and median prediction time of 59s. This study was prospective, single center, on 140 subjects to evaluate this VVS prediction algorithm and assess if retrospective results were reproduced and clinically relevant. Primary endpoint was VVS prediction: sensitivity and specificity >80%. In subjects, referred for 60° head-up tilt (Italian protocol), non-invasive HR and SBP were supplied to the VVS prediction algorithm: simultaneous analysis of RR intervals, SBP trends and their variability represented by low-frequency power generated cumulative risk which was compared with a predetermined VVS risk threshold. When cumulative risk exceeded threshold, an alert was generated. Prediction time was duration between first alert and syncope. Of 140 subjects enrolled, data was usable for 134. Of 83 tilt+ve (61.9%), 81 VVS events were correctly predicted and of 51 tilt-ve subjects (38.1%), 45 were correctly identified as negative by the algorithm. Resulting algorithm performance was sensitivity 97.6%, specificity 88.2%, meeting primary endpoint. Mean VVS prediction time was 2min 26s±3min16s with median 1min 25s. Using only HR and HR variability (without SBP) the mean prediction time reduced to 1min34s±1min45s with median 1min13s. The VVS prediction algorithm, is clinically-relevant tool and could offer applications including providing a patient alarm, shortening tilt-test time, or triggering pacing intervention in implantable devices. Copyright © 2018. Published by Elsevier Inc.

  14. Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus).

    PubMed

    Deng, Huaiqing; Gao, Kai; Zhou, Jiang

    2016-09-30

    Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002-2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7-10 min) followed by longer variable-frequency mobbing calls lasting 5-12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520-1000 Hz and 690-3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates' species. The system of vocal alarm behavior described in this critically endangered species is simple and effective.

  15. A cost analysis of a smoke alarm installation and fire safety education program.

    PubMed

    Parmer, John E; Corso, Phaedra S; Ballesteros, Michael F

    2006-01-01

    While smoke alarm installation programs can help prevent residential fire injuries, the costs of running these programs are not well understood. We conducted a retrospective cost analysis of a smoke alarm installation program in 12 funded communities across four states. Costs included financial and economic resources needed for training, canvassing, installing, and following-up, within four cost categories: (a) personnel, (b) transportation, (c) facility, and (d) supplies. Local cost per completed home visit averaged 214.54 dollars, with an average local cost per alarm installed of 115.02 dollars. Combined state and local cost per alarm installed across all four states averaged 132.15 dollars. For every 1% increase in alarm installation, costs per alarm decrease by 1.32 dollars. As more smoke alarms are installed, the average installation cost per alarm decreases. By demonstrating effective economies of scale, this study suggests that smoke alarm programs can be implemented efficiently and receive positive economic returns on investment.

  16. Evaluating Library Security Problems and Solutions.

    ERIC Educational Resources Information Center

    Nicely, Chris

    1993-01-01

    Discusses different types of security systems for libraries and explains the differences between electromagnetic, radio-frequency, and microwave technologies. A list of questions to assist in system evaluation is provided; and preventive measures used to curtail theft and protocol for handling situations that trigger security alarms are included.…

  17. Effect of subliminal visual material on an auditory signal detection task.

    PubMed

    Moroney, E; Bross, M

    1984-02-01

    An experiment assessed the effect of subliminally embedded, visual material on an auditory detection task. 22 women and 19 men were presented tachistoscopically with words designated as "emotional" or "neutral" on the basis of prior GSRs and a Word Rating List under four conditions: (a) Unembedded Neutral, (b) Embedded Neutral, (c) Unembedded Emotional, and (d) Embedded Emotional. On each trial subjects made forced choices concerning the presence or absence of an auditory tone (1000 Hz) at threshold level; hits and false alarm rates were used to compute non-parametric indices for sensitivity (A') and response bias (B"). While over-all analyses of variance yielded no significant differences, further examination of the data suggests the presence of subliminally "receptive" and "non-receptive" subpopulations.

  18. Analysis of Infrared Signature Variation and Robust Filter-Based Supersonic Target Detection

    PubMed Central

    Sun, Sun-Gu; Kim, Kyung-Tae

    2014-01-01

    The difficulty of small infrared target detection originates from the variations of infrared signatures. This paper presents the fundamental physics of infrared target variations and reports the results of variation analysis of infrared images acquired using a long wave infrared camera over a 24-hour period for different types of backgrounds. The detection parameters, such as signal-to-clutter ratio were compared according to the recording time, temperature and humidity. Through variation analysis, robust target detection methodologies are derived by controlling thresholds and designing a temporal contrast filter to achieve high detection rate and low false alarm rate. Experimental results validate the robustness of the proposed scheme by applying it to the synthetic and real infrared sequences. PMID:24672290

  19. Automatic detection, tracking and sensor integration

    NASA Astrophysics Data System (ADS)

    Trunk, G. V.

    1988-06-01

    This report surveys the state of the art of automatic detection, tracking, and sensor integration. In the area of detection, various noncoherent integrators such as the moving window integrator, feedback integrator, two-pole filter, binary integrator, and batch processor are discussed. Next, the three techniques for controlling false alarms, adapting thresholds, nonparametric detectors, and clutter maps are presented. In the area of tracking, a general outline is given of a track-while-scan system, and then a discussion is presented of the file system, contact-entry logic, coordinate systems, tracking filters, maneuver-following logic, tracking initiating, track-drop logic, and correlation procedures. Finally, in the area of multisensor integration the problems of colocated-radar integration, multisite-radar integration, radar-IFF integration, and radar-DF bearing strobe integration are treated.

  20. [Discuss about Alarm Requirements of Standards for Tests of Patient Monitor].

    PubMed

    Feng, Ting

    This paper introduces the alarm requirements of standards of patient monitor and expounds their significance for tests and guidance for patient monitor, then discusses whether technical alarm should not be closed and it latching alarm and non-latching alarm can not exist together.

  1. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground alarm systems. 57.4360 Section 57...

  2. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground alarm systems. 57.4360 Section 57...

  3. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground alarm systems. 57.4360 Section 57...

  4. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground alarm systems. 57.4360 Section 57...

  5. Alarm acknowledgement in a nuclear plant control room

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    Alarm acknowledgment can be made not only at the alarm tile array of a given console but via other touch sensitive alarm indications in the screen displays of the monitoring system at the same or other consoles; also, touching one tile can acknowledge multiple alarm sources.

  6. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  7. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  8. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  9. 46 CFR 108.627 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next to...

  10. 46 CFR 169.732 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...

  11. 46 CFR 169.732 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...

  12. 46 CFR 113.25-12 - Alarm signals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...

  13. 46 CFR 113.25-12 - Alarm signals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...

  14. Building Security. Honeywell Planning Guide.

    ERIC Educational Resources Information Center

    Honeywell, Inc., Minneapolis, Minn.

    A general discussion of building detection and alarm systems to provide security against burglary and vandalism is provided by a manufacturer of automated monitoring and control systems. Security systems are identified as--(1) local alarm system, (2) central station alarm system, (3) proprietary alarm system, and (4) direct connect alarm system..…

  15. 46 CFR 113.25-12 - Alarm signals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...

  16. 46 CFR 113.25-12 - Alarm signals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...

  17. 46 CFR 113.25-12 - Alarm signals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Alarm signals. 113.25-12 Section 113.25-12 Shipping... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-12 Alarm signals. (a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of...

  18. Remote Monitor Alarm System

    NASA Technical Reports Server (NTRS)

    Stute, Robert A. (Inventor); Galloway, F. Houston (Inventor); Medelius, Pedro J. (Inventor); Swindle, Robert W. (Inventor); Bierman, Tracy A. (Inventor)

    1996-01-01

    A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

  19. Hornbills can distinguish between primate alarm calls.

    PubMed Central

    Rainey, Hugo J.; Zuberbühler, Klaus; Slater, Peter J. B.

    2004-01-01

    Some mammals distinguish between and respond appropriately to the alarm calls of other mammal and bird species. However, the ability of birds to distinguish between mammal alarm calls has not been investigated. Diana monkeys (Cercopithecus diana) produce different alarm calls to two predators: crowned eagles (Stephanoaetus coronatus) and leopards (Panthera pardus). Yellow-casqued hornbills (Ceratogymna elata) are vulnerable to predation by crowned eagles but are not preyed on by leopards and might therefore be expected to respond to the Diana monkey eagle alarm call but not to the leopard alarm call. We compared responses of hornbills to playback of eagle shrieks, leopard growls, Diana monkey eagle alarm calls and Diana monkey leopard alarm calls and found that they distinguished appropriately between the two predator vocalizations as well as between the two Diana monkey alarm calls. We discuss possible mechanisms leading to these responses. PMID:15209110

  20. Performance of the species-typical alarm response in young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) is induced by interactions with mature workers.

    PubMed

    Cammaerts, Marie-Claire

    2014-01-01

    Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants' ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.

  1. Patient characteristics associated with false arrhythmia alarms in intensive care

    PubMed Central

    Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao

    2017-01-01

    Introduction A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. Results A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients’ annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years (P=0.013; P=0.034), confused mental status (P<0.001 for both comparisons), cardiovascular diagnoses (P<0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) (P=0.003; P=0.004) or ventricular paced rhythm (P=0.002 for both comparisons), respiratory diagnoses (P=0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones (P<0.001 for both comparisons). Conclusion Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management. PMID:28458554

  2. Randomized controlled trial of ionization and photoelectric smoke alarm functionality.

    PubMed

    Mueller, B A; Sidman, E A; Alter, H; Perkins, R; Grossman, D C

    2008-04-01

    To compare functionality, reasons for non-function, and nuisance alarm levels of two common types of smoke alarms after installation in low- to mid-level income households in King County, Washington. Randomized controlled trial of 761 households. An ionization or photoelectric smoke alarm was installed between June 1, 2000 and July 31, 2002. Main outcome measures were: percentage of study alarms that were working, observed reasons for non-functional status, and self-reported frequency of nuisance alarms at 9 and 15 months of follow-up. At 9 months after installation, 20% of ionization, vs 5% of photoelectric alarms were non-functional, a difference that persisted at 15 months, with the most common reasons for both types being a disconnected or absent battery. The risk ratio for ionization, relative to photoelectric alarms, being non-functional or removed was 2.7 (95% CI 1.8 to 4.1) at 15 months of follow-up. These findings were not altered by educational level, or the presence of smokers, children <5 years, or adults > or =65 years. Burn prevention efforts are geared towards increasing smoke alarm ownership and improving maintenance of functional status. Results suggest that the selective use of photoelectric alarms by fire injury prevention programs or consumers may provide longer-term protection in similar populations. Designing smoke alarms that minimize nuisance alarming may also result in longer term functionality.

  3. Smoke alarm ownership and installation: a comparison of a rural and a suburban community in Georgia.

    PubMed

    Jones, A R; Thompson, C J; Davis, M K

    2001-10-01

    As part of a smoke alarm giveaway and installation program (The Get-Alarmed Campaign), a total of 454 households were surveyed in two counties in Georgia, one metropolitan and one nonmetropolitan. The targeted communities in these counties had a high prevalence of low-income and minority populations and thus were at high risk of house fire-related morbidity and mortality. The objectives of the program were to determine the prevalence of and predictors for installed, functioning smoke alarms, and to install at least one smoke alarm and/or smoke alarm batteries in 100% of participating homes in need. Characteristics associated with smoke alarm ownership included home ownership, having a higher income, and having a central heating source, factors which should be considered in targeting future intervention strategies. At onset, 159/454 households (35.0%) had no smoke alarms installed and 56/275 households with existing smoke alarms (20.4%) had none that were functional. Regardless of ownership status, a free smoke alarm was installed in the household of 93.8% of participants and new batteries were installed in existing smoke alarms for 31.7% of participants. This project illustrates the usefulness of a door-to-door campaign in increasing smoke alarm ownership in both a rural and a suburban community with a high concentration of residents at high risk of house fire-related morbidity and mortality.

  4. A Parent-Oriented Approach to Rapid Toilet Training

    ERIC Educational Resources Information Center

    Doan, Dai; Toussaint, Karen A.

    2016-01-01

    The current evaluation assessed the effectiveness of a rapid toilet training procedure for three young males with autism. The evaluation extended the research on rapid toilet training procedures by assessing parents' preference to include two common toilet training components, a urine alarm and positive practice. In addition, we assessed child…

  5. 78 FR 21567 - Installation of Radiation Alarms for Rooms Housing Neutron Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-11

    ... [Docket No. PRM-73-15; NRC-2011-0251] Installation of Radiation Alarms for Rooms Housing Neutron Sources... amend its regulations to require the installation of radiation alarms for rooms housing neutron sources... alarms for rooms housing neutron sources. The petitioner stated that the use of alarms can be effective...

  6. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b) [Reserved] ...

  7. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  8. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  9. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  10. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...

  11. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...

  12. 46 CFR 108.627 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM...

  13. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...

  14. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...

  15. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Use of alarm signals. 80.318 Section 80.318... § 80.318 Use of alarm signals. (a) The radiotelegraph or radiotelephone alarm signal, as appropriate... transmission of an urgent cyclone warning. In this case the alarm signal may only be used by coast stations...

  16. Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus)

    PubMed Central

    Deng, Huaiqing; Gao, Kai; Zhou, Jiang

    2016-01-01

    Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002–2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7–10 min) followed by longer variable-frequency mobbing calls lasting 5–12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520–1000 Hz and 690–3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates’ species. The system of vocal alarm behavior described in this critically endangered species is simple and effective. PMID:27686623

  17. Types and Frequency of Infusion Pump Alarms: Protocol for a Retrospective Data Analysis.

    PubMed

    Glover, Kevin R; Vitoux, Rachel R; Schuster, Catherine; Curtin, Christopher R

    2018-06-14

    The variety of alarms from all types of medical devices has increased from 6 to 40 in the last three decades, with today's most critically ill patients experiencing as many as 45 alarms per hour. Alarm fatigue has been identified as a critical safety issue for clinical staff that can lead to potentially dangerous delays or nonresponse to actionable alarms, resulting in serious patient injury and death. To date, most research on medical device alarms has focused on the nonactionable alarms of physiological monitoring devices. While there have been some reports in the literature related to drug library alerts during the infusion pump programing sequence, research related to the types and frequencies of actionable infusion pump alarms remains largely unexplored. The objectives of this study protocol are to establish baseline data related to the types and frequency of infusion pump alarms from the B. Braun Outlook 400ES Safety Infusion System with the accompanying DoseTrac Infusion Management Software. The most recent consecutive 60-day period of backup hospital data received between April 2014 and February 2017 from 32 United States-based hospitals will be selected for analysis. Microsoft SQL Server (2012 - 11.0.5343.0 X64) will be used to manage the data with unique code written to sort data and perform descriptive analyses. A validated data management methodology will be utilized to clean and analyze the data. Data management procedures will include blinding, cleaning, and review of existing infusion data within the DoseTrac Infusion Management Software databases at each hospital. Patient-identifying data will be removed prior to merging into a dedicated and secure data repository. This pooled data will then be analyzed. This exploratory study will analyze the aggregate alarm data for each hospital by care area, drug infused, time of day, and day of week, including: overall infusion pump alarm frequency (number of alarms per active infusion), duration of alarms (average, range, median), and type and frequency of alarms distributed by care area. Infusion pump alarm data collected and analyzed in this study will be used to help establish a baseline of infusion pump alarm types and relative frequencies. Understanding the incidences and characteristics of infusion pump alarms will result in more informed quality improvement recommendations to decrease and/or modify infusion pump alarms, and potentially reduce clinical staff alarm fatigue and improve patient safety. . RR1-10.2196/10446. ©Kevin R Glover, Rachel R Vitoux, Catherine Schuster, Christopher R Curtin. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 14.06.2018.

  18. Fall Detection in Individuals With Lower Limb Amputations Using Mobile Phones: Machine Learning Enhances Robustness for Real-World Applications.

    PubMed

    Shawen, Nicholas; Lonini, Luca; Mummidisetty, Chaithanya Krishna; Shparii, Ilona; Albert, Mark V; Kording, Konrad; Jayaraman, Arun

    2017-10-11

    Automatically detecting falls with mobile phones provides an opportunity for rapid response to injuries and better knowledge of what precipitated the fall and its consequences. This is beneficial for populations that are prone to falling, such as people with lower limb amputations. Prior studies have focused on fall detection in able-bodied individuals using data from a laboratory setting. Such approaches may provide a limited ability to detect falls in amputees and in real-world scenarios. The aim was to develop a classifier that uses data from able-bodied individuals to detect falls in individuals with a lower limb amputation, while they freely carry the mobile phone in different locations and during free-living. We obtained 861 simulated indoor and outdoor falls from 10 young control (non-amputee) individuals and 6 individuals with a lower limb amputation. In addition, we recorded a broad database of activities of daily living, including data from three participants' free-living routines. Sensor readings (accelerometer and gyroscope) from a mobile phone were recorded as participants freely carried it in three common locations-on the waist, in a pocket, and in the hand. A set of 40 features were computed from the sensors data and four classifiers were trained and combined through stacking to detect falls. We compared the performance of two population-specific models, trained and tested on either able-bodied or amputee participants, with that of a model trained on able-bodied participants and tested on amputees. A simple threshold-based classifier was used to benchmark our machine-learning classifier. The accuracy of fall detection in amputees for a model trained on control individuals (sensitivity: mean 0.989, 1.96*standard error of the mean [SEM] 0.017; specificity: mean 0.968, SEM 0.025) was not statistically different (P=.69) from that of a model trained on the amputee population (sensitivity: mean 0.984, SEM 0.016; specificity: mean 0.965, SEM 0.022). Detection of falls in control individuals yielded similar results (sensitivity: mean 0.979, SEM 0.022; specificity: mean 0.991, SEM 0.012). A mean 2.2 (SD 1.7) false alarms per day were obtained when evaluating the model (vs mean 122.1, SD 166.1 based on thresholds) on data recorded as participants carried the phone during their daily routine for two or more days. Machine-learning classifiers outperformed the threshold-based one (P<.001). A mobile phone-based fall detection model can use data from non-amputee individuals to detect falls in individuals walking with a prosthesis. We successfully detected falls when the mobile phone was carried across multiple locations and without a predetermined orientation. Furthermore, the number of false alarms yielded by the model over a longer period of time was reasonably low. This moves the application of mobile phone-based fall detection systems closer to a real-world use case scenario. ©Nicholas Shawen, Luca Lonini, Chaithanya Krishna Mummidisetty, Ilona Shparii, Mark V Albert, Konrad Kording, Arun Jayaraman. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 11.10.2017.

  19. A Fault Alarm and Diagnosis Method Based on Sensitive Parameters and Support Vector Machine

    NASA Astrophysics Data System (ADS)

    Zhang, Jinjie; Yao, Ziyun; Lv, Zhiquan; Zhu, Qunxiong; Xu, Fengtian; Jiang, Zhinong

    2015-08-01

    Study on the extraction of fault feature and the diagnostic technique of reciprocating compressor is one of the hot research topics in the field of reciprocating machinery fault diagnosis at present. A large number of feature extraction and classification methods have been widely applied in the related research, but the practical fault alarm and the accuracy of diagnosis have not been effectively improved. Developing feature extraction and classification methods to meet the requirements of typical fault alarm and automatic diagnosis in practical engineering is urgent task. The typical mechanical faults of reciprocating compressor are presented in the paper, and the existing data of online monitoring system is used to extract fault feature parameters within 15 types in total; the inner sensitive connection between faults and the feature parameters has been made clear by using the distance evaluation technique, also sensitive characteristic parameters of different faults have been obtained. On this basis, a method based on fault feature parameters and support vector machine (SVM) is developed, which will be applied to practical fault diagnosis. A better ability of early fault warning has been proved by the experiment and the practical fault cases. Automatic classification by using the SVM to the data of fault alarm has obtained better diagnostic accuracy.

  20. Effects of natural and synthetic alarm pheromone and individual pheromone components on foraging behavior of the giant Asian honey bee, Apis dorsata.

    PubMed

    Li, Jianjun; Wang, Zhengwei; Tan, Ken; Qu, Yufeng; Nieh, James C

    2014-10-01

    Social pollinators such as honey bees face attacks from predators not only at the nest, but also during foraging. Pollinating honey bees can therefore release alarm pheromones that deter conspecifics from visiting dangerous inflorescences. However, the effect of alarm pheromone and its chemical components upon bee avoidance of dangerous food sources remains unclear. We tested the responses of giant honey bee foragers, Apis dorsata, presented with alarm pheromone at a floral array. Foragers investigated the inflorescence with natural alarm pheromone, but 3.3-fold more foragers preferred to land on the 'safe' inflorescence without alarm pheromone. Using gas chromatography-mass spectrometry analysis, we identified eight chemical components in the alarm pheromone, of which three components (1-octanol, decanal and gamma-octanoic lactone) have not previously been reported in this species. We bioassayed six major compounds and found that a synthetic mixture of these compounds elicited behaviors statistically indistinguishable from responses to natural alarm pheromone. By testing each compound separately, we show that gamma-octanoic lactone, isopentyl acetate and (E)-2-decen-1-yl acetate are active compounds that elicit significant alarm responses. Gamma-octanoic lactone elicited the strongest response to a single compound and has not been previously reported in honey bee alarm pheromone. Isopentyl acetate is widely found in the alarm pheromones of sympatric Asian honey bee species, and thus alarmed A. dorsata foragers may produce information useful for conspecifics and heterospecifics, thereby broadening the effects of alarm information on plant pollination. © 2014. Published by The Company of Biologists Ltd.

  1. The Effectiveness of a Wireless Modular Bed Absence Sensor Device for Fall Prevention among Older Inpatients.

    PubMed

    Subermaniam, Kogilavani; Welfred, Ridgwan; Subramanian, Pathmawathi; Chinna, Karuthan; Ibrahim, Fatimah; Mohktar, Mas S; Tan, Maw Pin

    2016-01-01

    Falls and fall-related injuries are increasingly serious issues among elderly inpatients due to population aging. The bed-exit alarm has only previously been evaluated in a handful of studies with mixed results. Therefore, we evaluated the effectiveness of a modular bed absence sensor device (M-BAS) in detecting bed exits among older inpatients in a middle income nation in East Asia. Patients aged ≥65 years on an acute geriatric ward who were able to mobilize with or without walking aids and physical assistance were recruited to the study. The total number of alarms and the numbers of true and false alarms were recorded by ward nurses. The M-BAS device is placed across the mattress of all consenting participants. Nurses' workload was assessed using the National Aeronautics and Space Administration-Task Load Index (NASA-TLX) score, while nurses' perceptions were surveyed. The sensitivity of the M-BAS was 100% with a positive predictive value of 68% and a nuisance alarm rate of 31%. There was a significant reduction in total NASA-TLX workload score (mean difference = 14.34 ± 13.96 SD, p  < 0.001) at the end of the intervention period. 83% of the nurses found the device useful for falls prevention, 97% found it user friendly, and 87% would use it in future. The M-BAS was able to accurately detect bed absence episodes among geriatric inpatients and alert nurses accordingly. The use of the device significantly reduced the total workload score, while the acceptability of the device was high among our nurses. A larger, cluster randomized study to measure actual falls outcome associated with the use of the device is now indicated.

  2. Smoke alarm giveaway and installation programs: an economic evaluation.

    PubMed

    Liu, Ying; Mack, Karin A; Diekman, Shane T

    2012-10-01

    The burden of residential fire injury and death is substantial. Targeted smoke alarm giveaway and installation programs are popular interventions used to reduce residential fire mortality and morbidity. To evaluate the cost effectiveness and cost benefit of implementing a giveaway or installation program in a small hypothetic community with a high risk of fire death and injury through a decision-analysis model. Model inputs included program costs; program effectiveness (life-years and quality-adjusted life-years saved); and monetized program benefits (medical cost, productivity, property loss and quality-of-life losses averted) and were identified through structured reviews of existing literature (done in 2011) and supplemented by expert opinion. Future costs and effectiveness were discounted at a rate of 3% per year. All costs were expressed in 2011 U.S. dollars. Cost-effectiveness analysis (CEA) resulted in an average cost-effectiveness ratio (ACER) of $51,404 per quality-adjusted life-years (QALYs) saved and $45,630 per QALY for the giveaway and installation programs, respectively. Cost-benefit analysis (CBA) showed that both programs were associated with a positive net benefit with a benefit-cost ratio of 2.1 and 2.3, respectively. Smoke alarm functional rate, baseline prevalence of functional alarms, and baseline home fire death rate were among the most influential factors for the CEA and CBA results. Both giveaway and installation programs have an average cost-effectiveness ratio similar to or lower than the median cost-effectiveness ratio reported for other interventions to reduce fatal injuries in homes. Although more effort is required, installation programs result in lower cost per outcome achieved compared with giveaways. Published by Elsevier Inc.

  3. Automated real time constant-specificity surveillance for disease outbreaks.

    PubMed

    Wieland, Shannon C; Brownstein, John S; Berger, Bonnie; Mandl, Kenneth D

    2007-06-13

    For real time surveillance, detection of abnormal disease patterns is based on a difference between patterns observed, and those predicted by models of historical data. The usefulness of outbreak detection strategies depends on their specificity; the false alarm rate affects the interpretation of alarms. We evaluate the specificity of five traditional models: autoregressive, Serfling, trimmed seasonal, wavelet-based, and generalized linear. We apply each to 12 years of emergency department visits for respiratory infection syndromes at a pediatric hospital, finding that the specificity of the five models was almost always a non-constant function of the day of the week, month, and year of the study (p < 0.05). We develop an outbreak detection method, called the expectation-variance model, based on generalized additive modeling to achieve a constant specificity by accounting for not only the expected number of visits, but also the variance of the number of visits. The expectation-variance model achieves constant specificity on all three time scales, as well as earlier detection and improved sensitivity compared to traditional methods in most circumstances. Modeling the variance of visit patterns enables real-time detection with known, constant specificity at all times. With constant specificity, public health practitioners can better interpret the alarms and better evaluate the cost-effectiveness of surveillance systems.

  4. Isolation of a pyrazine alarm pheromone component from the fire ant, Solenopsis invicta.

    PubMed

    Vander Meer, Robert K; Preston, Catherine A; Choi, Man-Yeon

    2010-02-01

    Alarm pheromones in social insects are an essential part of a complex of pheromone interactions that contribute to the maintenance of colony integrity and sociality. The alarm pheromones of ants were among the first examples of animal pheromones identified, primarily because of the large amount of chemical produced and the distinctive responses of ants to the pheromone. However, the alarm pheromone of the fire ant, Solenopsis invicta, eluded identification for over four decades. We identified 2-ethyl-3,6-dimethylpyrazine as an alarm pheromone component of S. invicta. Worker fire ants detect the pyrazine alarm pheromone at 30 pg/ml, which is comparable to alarm pheromone sensitivities reported for other ant species. The source of this alarm pheromone are the mandibular glands, which, in fire ants, are not well developed and contain only about 300 pg of the compound, much less than the microgram quantities of alarm pheromones reported for several other ant species. Female and male sexuals and workers produce the pyrazine, which suggests that it may be involved in fire ant mating flight initiation, as well as the typical worker alarm response. This is the first report of 2-ethyl-3,6-dimethylpyrazine from a Solenopsis species and the first example of this alkaloid functioning as an alarm pheromone.

  5. Istanbul Earthquake Early Warning and Rapid Response System

    NASA Astrophysics Data System (ADS)

    Erdik, M. O.; Fahjan, Y.; Ozel, O.; Alcik, H.; Aydin, M.; Gul, M.

    2003-12-01

    As part of the preparations for the future earthquake in Istanbul a Rapid Response and Early Warning system in the metropolitan area is in operation. For the Early Warning system ten strong motion stations were installed as close as possible to the fault zone. Continuous on-line data from these stations via digital radio modem provide early warning for potentially disastrous earthquakes. Considering the complexity of fault rupture and the short fault distances involved, a simple and robust Early Warning algorithm, based on the exceedance of specified threshold time domain amplitude levels is implemented. The band-pass filtered accelerations and the cumulative absolute velocity (CAV) are compared with specified threshold levels. When any acceleration or CAV (on any channel) in a given station exceeds specific threshold values it is considered a vote. Whenever we have 2 station votes within selectable time interval, after the first vote, the first alarm is declared. In order to specify the appropriate threshold levels a data set of near field strong ground motions records form Turkey and the world has been analyzed. Correlations among these thresholds in terms of the epicenter distance the magnitude of the earthquake have been studied. The encrypted early warning signals will be communicated to the respective end users by UHF systems through a "service provider" company. The users of the early warning signal will be power and gas companies, nuclear research facilities, critical chemical factories, subway system and several high-rise buildings. Depending on the location of the earthquake (initiation of fault rupture) and the recipient facility the alarm time can be as high as about 8s. For the rapid response system one hundred 18 bit-resolution strong motion accelerometers were placed in quasi-free field locations (basement of small buildings) in the populated areas of the city, within an area of approximately 50x30km, to constitute a network that will enable early damage assessment and rapid response information after a damaging earthquake. Early response information is achieved through fast acquisition and analysis of processed data obtained from the network. The stations are routinely interrogated on regular basis by the main data center. After triggered by an earthquake, each station processes the streaming strong motion data to yield the spectral accelerations at specific periods, 12Hz filtered PGA and PGV and will send these parameters in the form of SMS messages at every 20s directly to the main data center through a designated GSM network and through a microwave system. A shake map and damage distribution map (using aggregate building inventories and fragility curves) will be automatically generated using the algorithm developed for this purpose. Loss assessment studies are complemented by a large citywide digital database on the topography, geology, soil conditions, building, infrastructure and lifeline inventory. The shake and damage maps will be conveyed to the governor's and mayor's offices, fire, police and army headquarters within 3 minutes using radio modem and GPRS communication. An additional forty strong motion recorders were placed on important structures in several interconnected clusters to monitor the health of these structures after a damaging earthquake.

  6. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM...

  7. Bonneville Power Administration Communication Alarm Processor expert system:

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goeltz, R.; Purucker, S.; Tonn, B.

    This report describes the Communications Alarm Processor (CAP), a prototype expert system developed for the Bonneville Power Administration by Oak Ridge National Laboratory. The system is designed to receive and diagnose alarms from Bonneville's Microwave Communications System (MCS). The prototype encompasses one of seven branches of the communications network and a subset of alarm systems and alarm types from each system. The expert system employs a backward chaining approach to diagnosing alarms. Alarms are fed into the expert system directly from the communication system via RS232 ports and sophisticated alarm filtering and mailbox software. Alarm diagnoses are presented to operatorsmore » for their review and concurrence before the diagnoses are archived. Statistical software is incorporated to allow analysis of archived data for report generation and maintenance studies. The delivered system resides on a Digital Equipment Corporation VAX 3200 workstation and utilizes Nexpert Object and SAS for the expert system and statistical analysis, respectively. 11 refs., 23 figs., 7 tabs.« less

  8. Alarms Philosophy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Karen S; Kasemir, Kay

    2009-01-01

    An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits.more » In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.« less

  9. Prevalence of residential smoke alarms and fire escape plans in the U.S.: results from the Second Injury Control and Risk Survey (ICARIS-2).

    PubMed

    Ballesteros, Michael F; Kresnow, Marcie-Jo

    2007-01-01

    This study was conducted to estimate (1) the proportion of U.S. homes with installed smoke alarms and fire escape plans, and (2) the frequency of testing home smoke alarms and of practicing the fire escape plans. The authors analyzed data on smoke alarms and fire escape plans from a national cross-sectional random-digit dialed telephone survey of 9,684 households. Ninety-five percent of surveyed households reported at least one installed smoke alarm and 52% had a fire escape plan. The prevalence of alarms varied by educational level, income, and the presence of a child in the home. Only 15% tested their alarms once a month and only 16% of homes with an escape plan reported practicing it every six months. While smoke alarm prevalence in U.S. homes is high, only half of homes have a fire escape plan. Additional emphasis is needed on testing of installed smoke alarms and on preparedness for fire escape plans.

  10. Composing alarms: considering the musical aspects of auditory alarm design.

    PubMed

    Gillard, Jessica; Schutz, Michael

    2016-12-01

    Short melodies are commonly linked to referents in jingles, ringtones, movie themes, and even auditory displays (i.e., sounds used in human-computer interactions). While melody associations can be quite effective, auditory alarms in medical devices are generally poorly learned and highly confused. Here, we draw on approaches and stimuli from both music cognition (melody recognition) and human factors (alarm design) to analyze the patterns of confusions in a paired-associate alarm-learning task involving both a standardized melodic alarm set (Experiment 1) and a set of novel melodies (Experiment 2). Although contour played a role in confusions (consistent with previous research), we observed several cases where melodies with similar contours were rarely confused - melodies holding musically distinctive features. This exploratory work suggests that salient features formed by an alarm's melodic structure (such as repeated notes, distinct contours, and easily recognizable intervals) can increase the likelihood of correct alarm identification. We conclude that the use of musical principles and features may help future efforts to improve the design of auditory alarms.

  11. Toward personal eHealth in cardiology. Results from the EPI-MEDICS telemedicine project.

    PubMed

    Rubel, Paul; Fayn, Jocelyne; Nollo, Giandomenico; Assanelli, Deodato; Li, Bo; Restier, Lioara; Adami, Stefano; Arod, Sébastien; Atoui, Hussein; Ohlsson, Mattias; Simon-Chautemps, Lucas; Télisson, David; Malossi, Cesare; Ziliani, Gian-Luca; Galassi, Alfredo; Edenbrandt, Lars; Chevalier, Philippe

    2005-10-01

    Despite many attempts to improve the management of acute myocardial infarction, only small trends to shorter time intervals before treatment have been reported. The self-care solution developed by the European EPI-MEDICS project (2001-2004) is a novel, very affordable, easy-to-use, portable, and intelligent Personal ECG Monitor (PEM) for the early detection of cardiac ischemia and arrhythmia that is able to record a professional-quality, 3-lead electrocardiogram (ECG) based on leads I, II, and V2; derive the missing leads of the standard 12-lead ECG (thanks to either a generic or a patient-specific transform), compare each ECG with a reference ECG by means of advanced neural network-based decision-making methods taking into account the serial ECG measurements and the patient risk factors and clinical data; and generate different levels of alarms and forward the alarm messages with the recorded ECGs and the patient's Personal electronic Health Record (PHR) to the relevant health care providers by means of a standard Bluetooth-enabled, GSM/GPRS-compatible mobile phone. The ECG records are SCP-ECG encoded and stored with the PHR on a secure personal SD Card embedded in the PEM device. The alarm messages and the PHR are XML encoded. Major alarm messages are automatically transmitted to the nearest emergency call center. Medium or minor alarms are sent on demand to a central PEM Alarm Web Server. Health professionals are informed by a Short Message Service. The PEM embeds itself a Web server to facilitate the reviewing and/or update of the PHR during a routine visit at the office of the general physician or cardiologist. Eighty PEM prototypes have been finalized and tested for several weeks on 697 citizens/patients in different clinical and self-care situations involving end users (188 patients), general physicians (10), and cardiologists (9). The clinical evaluation indicates that the EPI-MEDICS concept may save lives and is very valuable for prehospitalization triage.

  12. Addition of Alarm Pheromone Components Improves the Effectiveness of Desiccant Dusts Against Cimex lectularius

    PubMed Central

    BENOIT, JOSHUA B.; PHILLIPS, SETH A.; CROXALL, TRAVIS J.; CHRISTENSEN, BRADY S.; YODER, JAY A.; DENLINGER, DAVID L.

    2009-01-01

    We demonstrate that the addition of bed bug, Cimex lectularius, alarm pheromone to desiccant formulations greatly enhances their effectiveness during short-term exposure. Two desiccant formulations, diatomaceous earth (DE) and Dri-die (silica gel), were applied at the label rate with and without bed bug alarm pheromone components, (E)-2-hexenal, (E)-2-octenal, and a (E)-2-hexenal:(E)-2-octenal blend. First-instar nymphs and adult females were subjected to 10-min exposures, and water loss rates were used to evaluate the response. Optimal effectiveness was achieved with a pheromone concentration of 0.01 M. With Dri-die alone, the water loss was 21% higher than in untreated controls, and water loss increased nearly two times with (E)-2-hexenal and (E)-2-octenal and three times with the (E)-2-hexenal: (E)-2-octenal blend. This shortened survival of first-instar nymphs from 4 to 1 d, with a similar reduction noted in adult females. DE was effective only if supplemented with pheromone, resulting in a 50% increase in water loss over controls with the (E)-2-hexenal:(E)-2-octenal blend, and a survival decrease from 4 to 2 d in first-instar nymphs. Consistently, the addition of the pheromone blend to desiccant dust was more effective than adding either component by itself or by using Dri-die or DE alone. Based on observations in a small microhabitat, the addition of alarm pheromone components prompted bed bugs to leave their protective harborages and to move through the desiccant, improving the use of desiccants for control. We concluded that short exposure to Dri-die is a more effective treatment against bed bugs than DE and that the effectiveness of the desiccants can be further enhanced by incorporation of alarm pheromone. Presumably, the addition of alarm pheromone elevates excited crawling activity, thereby promoting cuticular changes that increase water loss. PMID:19496429

  13. Evaluation of a fault tolerant system for an integrated avionics sensor configuration with TSRV flight data

    NASA Technical Reports Server (NTRS)

    Caglayan, A. K.; Godiwala, P. M.

    1985-01-01

    The performance analysis results of a fault inferring nonlinear detection system (FINDS) using sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment is presented. First, a statistical analysis of the flight recorded sensor data was made in order to determine the characteristics of sensor inaccuracies. Next, modifications were made to the detection and decision functions in the FINDS algorithm in order to improve false alarm and failure detection performance under real modelling errors present in the flight data. Finally, the failure detection and false alarm performance of the FINDS algorithm were analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minute flight data. In general, the detection speed, failure level estimation, and false alarm performance showed a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed was faster for filter measurement sensors soon as MLS than for filter input sensors such as flight control accelerometers.

  14. Performance of fusion algorithms for computer-aided detection and classification of mines in very shallow water obtained from testing in navy Fleet Battle Exercise-Hotel 2000

    NASA Astrophysics Data System (ADS)

    Ciany, Charles M.; Zurawski, William; Kerfoot, Ian

    2001-10-01

    The performance of Computer Aided Detection/Computer Aided Classification (CAD/CAC) Fusion algorithms on side-scan sonar images was evaluated using data taken at the Navy's's Fleet Battle Exercise-Hotel held in Panama City, Florida, in August 2000. A 2-of-3 binary fusion algorithm is shown to provide robust performance. The algorithm accepts the classification decisions and associated contact locations form three different CAD/CAC algorithms, clusters the contacts based on Euclidian distance, and then declares a valid target when a clustered contact is declared by at least 2 of the 3 individual algorithms. This simple binary fusion provided a 96 percent probability of correct classification at a false alarm rate of 0.14 false alarms per image per side. The performance represented a 3.8:1 reduction in false alarms over the best performing single CAD/CAC algorithm, with no loss in probability of correct classification.

  15. An algorithm to detect fire activity using Meteosat: fine tuning and quality assesment

    NASA Astrophysics Data System (ADS)

    Amraoui, M.; DaCamara, C. C.; Ermida, S. L.

    2012-04-01

    Hot spot detection by means of sensors on-board geostationary satellites allows studying wildfire activity at hourly and even sub-hourly intervals, an advantage that cannot be met by polar orbiters. Since 1997, the Satellite Application Facility for Land Surface Analysis has been running an operational procedure that allows detecting active fires based on information from Meteosat-8/SEVIRI. This is the so-called Fire Detection and Monitoring (FD&M) product and the procedure takes advantage of the temporal resolution of SEVIRI (one image every 15 min), and relies on information from SEVIRI channels (namely 0.6, 0.8, 3.9, 10.8 and 12.0 μm) together with information on illumination angles. The method is based on heritage from contextual algorithms designed for polar, sun-synchronous instruments, namely NOAA/AVHRR and MODIS/TERRAAQUA. A potential fire pixel is compared with the neighboring ones and the decision is made based on relative thresholds as derived from the pixels in the neighborhood. Generally speaking, the observed fire incidence compares well against hot spots extracted from the global daily active fire product developed by the MODIS Fire Team. However, values of probability of detection (POD) tend to be quite low, a result that may be partially expected by the finer resolution of MODIS. The aim of the present study is to make a systematic assessment of the impacts on POD and False Alarm Ratio (FAR) of the several parameters that are set in the algorithms. Such parameters range from the threshold values of brightness temperature in the IR3.9 and 10.8 channels that are used to select potential fire pixels up to the extent of the background grid and thresholds used to statistically characterize the radiometric departures of a potential pixel from the respective background. The impact of different criteria to identify pixels contaminated by clouds, smoke and sun glint is also evaluated. Finally, the advantages that may be brought to the algorithm by adding contextual tests in the time domain are discussed. The study lays the grounds to the development of improved quality flags that will be integrated in the FD&M product in the nearby future.

  16. Cryptic diversity and discordance in single-locus species delimitation methods within horned lizards (Phrynosomatidae: Phrynosoma).

    PubMed

    Blair, Christopher; Bryson, Robert W

    2017-11-01

    Biodiversity reduction and loss continues to progress at an alarming rate, and thus, there is widespread interest in utilizing rapid and efficient methods for quantifying and delimiting taxonomic diversity. Single-locus species delimitation methods have become popular, in part due to the adoption of the DNA barcoding paradigm. These techniques can be broadly classified into tree-based and distance-based methods depending on whether species are delimited based on a constructed genealogy. Although the relative performance of these methods has been tested repeatedly with simulations, additional studies are needed to assess congruence with empirical data. We compiled a large data set of mitochondrial ND4 sequences from horned lizards (Phrynosoma) to elucidate congruence using four tree-based (single-threshold GMYC, multiple-threshold GMYC, bPTP, mPTP) and one distance-based (ABGD) species delimitation models. We were particularly interested in cases with highly uneven sampling and/or large differences in intraspecific diversity. Results showed a high degree of discordance among methods, with multiple-threshold GMYC and bPTP suggesting an unrealistically high number of species (29 and 26 species within the P. douglasii complex alone). The single-threshold GMYC model was the most conservative, likely a result of difficulty in locating the inflection point in the genealogies. mPTP and ABGD appeared to be the most stable across sampling regimes and suggested the presence of additional cryptic species that warrant further investigation. These results suggest that the mPTP model may be preferable in empirical data sets with highly uneven sampling or large differences in effective population sizes of species. © 2017 John Wiley & Sons Ltd.

  17. Smoke alarms in the home: what every physician should know

    PubMed Central

    Sultan, Mohammed A.; Feldman, William M.

    1985-01-01

    Primary care physicians interested in health education and accident prevention should be knowledgeable about smoke alarms (smoke detectors with built-in alarms). Either ionization or photoelectric smoke alarms can help save lives if they are properly installed and maintained. The number, site and maintenance of smoke alarms in the home and the steps a person should take in the event of a fire are discussed. Considering the rates of death, disability and disfigurement associated with residential fires, early warning devices such as smoke alarms make sense. PMID:4063931

  18. A study on the use of Gumbel approximation with the Bernoulli spatial scan statistic.

    PubMed

    Read, S; Bath, P A; Willett, P; Maheswaran, R

    2013-08-30

    The Bernoulli version of the spatial scan statistic is a well established method of detecting localised spatial clusters in binary labelled point data, a typical application being the epidemiological case-control study. A recent study suggests the inferential accuracy of several versions of the spatial scan statistic (principally the Poisson version) can be improved, at little computational cost, by using the Gumbel distribution, a method now available in SaTScan(TM) (www.satscan.org). We study in detail the effect of this technique when applied to the Bernoulli version and demonstrate that it is highly effective, albeit with some increase in false alarm rates at certain significance thresholds. We explain how this increase is due to the discrete nature of the Bernoulli spatial scan statistic and demonstrate that it can affect even small p-values. Despite this, we argue that the Gumbel method is actually preferable for very small p-values. Furthermore, we extend previous research by running benchmark trials on 12 000 synthetic datasets, thus demonstrating that the overall detection capability of the Bernoulli version (i.e. ratio of power to false alarm rate) is not noticeably affected by the use of the Gumbel method. We also provide an example application of the Gumbel method using data on hospital admissions for chronic obstructive pulmonary disease. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Ensuring long-term reliability of the data storage on optical disc

    NASA Astrophysics Data System (ADS)

    Chen, Ken; Pan, Longfa; Xu, Bin; Liu, Wei

    2008-12-01

    "Quality requirements and handling regulation of archival optical disc for electronic records filing" is released by The State Archives Administration of the People's Republic of China (SAAC) on its network in March 2007. This document established a complete operative managing process for optical disc data storage in archives departments. The quality requirements of the optical disc used in archives departments are stipulated. Quality check of the recorded disc before filing is considered to be necessary and the threshold of the parameter of the qualified filing disc is set down. The handling regulations for the staffs in the archives departments are described. Recommended environment conditions of the disc preservation, recording, accessing and testing are presented. The block error rate of the disc is selected as main monitoring parameter of the lifetime of the filing disc and three classes pre-alarm lines are created for marking of different quality check intervals. The strategy of monitoring the variation of the error rate curve of the filing discs and moving the data to a new disc or a new media when the error rate of the disc reaches the third class pre-alarm line will effectively guarantee the data migration before permanent loss. Only when every step of the procedure is strictly implemented, it is believed that long-term reliability of the data storage on optical disc for archives departments can be effectively ensured.

  20. Accurate identification of motor unit discharge patterns from high-density surface EMG and validation with a novel signal-based performance metric

    NASA Astrophysics Data System (ADS)

    Holobar, A.; Minetto, M. A.; Farina, D.

    2014-02-01

    Objective. A signal-based metric for assessment of accuracy of motor unit (MU) identification from high-density surface electromyograms (EMG) is introduced. This metric, so-called pulse-to-noise-ratio (PNR), is computationally efficient, does not require any additional experimental costs and can be applied to every MU that is identified by the previously developed convolution kernel compensation technique. Approach. The analytical derivation of the newly introduced metric is provided, along with its extensive experimental validation on both synthetic and experimental surface EMG signals with signal-to-noise ratios ranging from 0 to 20 dB and muscle contraction forces from 5% to 70% of the maximum voluntary contraction. Main results. In all the experimental and simulated signals, the newly introduced metric correlated significantly with both sensitivity and false alarm rate in identification of MU discharges. Practically all the MUs with PNR > 30 dB exhibited sensitivity >90% and false alarm rates <2%. Therefore, a threshold of 30 dB in PNR can be used as a simple method for selecting only reliably decomposed units. Significance. The newly introduced metric is considered a robust and reliable indicator of accuracy of MU identification. The study also shows that high-density surface EMG can be reliably decomposed at contraction forces as high as 70% of the maximum.

  1. VizieR Online Data Catalog: Bayesian method for detecting stellar flares (Pitkin+, 2014)

    NASA Astrophysics Data System (ADS)

    Pitkin, M.; Williams, D.; Fletcher, L.; Grant, S. D. T.

    2015-05-01

    We present a Bayesian-odds-ratio-based algorithm for detecting stellar flares in light-curve data. We assume flares are described by a model in which there is a rapid rise with a half-Gaussian profile, followed by an exponential decay. Our signal model also contains a polynomial background model required to fit underlying light-curve variations in the data, which could otherwise partially mimic a flare. We characterize the false alarm probability and efficiency of this method under the assumption that any unmodelled noise in the data is Gaussian, and compare it with a simpler thresholding method based on that used in Walkowicz et al. We find our method has a significant increase in detection efficiency for low signal-to-noise ratio (S/N) flares. For a conservative false alarm probability our method can detect 95 per cent of flares with S/N less than 20, as compared to S/N of 25 for the simpler method. We also test how well the assumption of Gaussian noise holds by applying the method to a selection of 'quiet' Kepler stars. As an example we have applied our method to a selection of stars in Kepler Quarter 1 data. The method finds 687 flaring stars with a total of 1873 flares after vetos have been applied. For these flares we have made preliminary characterizations of their durations and and S/N. (1 data file).

  2. A Bayesian method for detecting stellar flares

    NASA Astrophysics Data System (ADS)

    Pitkin, M.; Williams, D.; Fletcher, L.; Grant, S. D. T.

    2014-12-01

    We present a Bayesian-odds-ratio-based algorithm for detecting stellar flares in light-curve data. We assume flares are described by a model in which there is a rapid rise with a half-Gaussian profile, followed by an exponential decay. Our signal model also contains a polynomial background model required to fit underlying light-curve variations in the data, which could otherwise partially mimic a flare. We characterize the false alarm probability and efficiency of this method under the assumption that any unmodelled noise in the data is Gaussian, and compare it with a simpler thresholding method based on that used in Walkowicz et al. We find our method has a significant increase in detection efficiency for low signal-to-noise ratio (S/N) flares. For a conservative false alarm probability our method can detect 95 per cent of flares with S/N less than 20, as compared to S/N of 25 for the simpler method. We also test how well the assumption of Gaussian noise holds by applying the method to a selection of `quiet' Kepler stars. As an example we have applied our method to a selection of stars in Kepler Quarter 1 data. The method finds 687 flaring stars with a total of 1873 flares after vetos have been applied. For these flares we have made preliminary characterizations of their durations and and S/N.

  3. Deficits in the Sensitivity to Pitch Sweeps by School-Aged Children Wearing Cochlear Implants

    PubMed Central

    Deroche, Mickael L. D.; Kulkarni, Aditya M.; Christensen, Julie A.; Limb, Charles J.; Chatterjee, Monita

    2016-01-01

    Sensitivity to static changes in pitch has been shown to be poorer in school-aged children wearing cochlear implants (CIs) than children with normal hearing (NH), but it is unclear whether this is also the case for dynamic changes in pitch. Yet, dynamically changing pitch has considerable ecological relevance in terms of natural speech, particularly aspects such as intonation, emotion, or lexical tone information. Twenty one children with NH and 23 children wearing a CI participated in this study, along with 18 NH adults and 6 CI adults for comparison. Listeners with CIs used their clinically assigned settings with envelope-based coding strategies. Percent correct was measured in one- or three-interval two-alternative forced choice tasks, for the direction or discrimination of harmonic complexes based on a linearly rising or falling fundamental frequency. Sweep rates were adjusted per subject, in a logarithmic scale, so as to cover the full extent of the psychometric function. Data for up- and down-sweeps were fitted separately, using a maximum-likelihood technique. Fits were similar for up- and down-sweeps in the discrimination task, but diverged in the direction task because psychometric functions for down-sweeps were very shallow. Hits and false alarms were then converted into d′ and beta values, from which a threshold was extracted at a d′ of 0.77. Thresholds were very consistent between the two tasks and considerably higher (worse) for CI listeners than for their NH peers. Thresholds were also higher for children than adults. Factors such as age at implantation, age at profound hearing loss, and duration of CI experience did not play any major role in this sensitivity. Thresholds of dynamic pitch sensitivity (in either task) also correlated with thresholds for static pitch sensitivity and with performance in tasks related to speech prosody. PMID:26973451

  4. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae): the integration of chemical and vibroacoustic signals

    PubMed Central

    Cristaldo, Paulo F.; Jandák, Vojtĕch; Kutalová, Kateřina; Rodrigues, Vinícius B.; Brothánek, Marek; Jiříček, Ondřej; DeSouza, Og; Šobotník, Jan

    2015-01-01

    ABSTRACT Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae), confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S)-α-pinene and myrcene, along with a minor component, (E)-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards) resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant) increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through vibratory signals, and higher levels causing general alarm or retreat being communicated through the alarm pheromone. PMID:26538635

  5. A new function for estimating local rainfall thresholds for landslide triggering

    NASA Astrophysics Data System (ADS)

    Cepeda, J.; Nadim, F.; Høeg, K.; Elverhøi, A.

    2009-04-01

    The widely used power law for establishing rainfall thresholds for triggering of landslides was first proposed by N. Caine in 1980. The most updated global thresholds presented by F. Guzzetti and co-workers in 2008 were derived using Caine's power law and a rigorous and comprehensive collection of global data. Caine's function is defined as I = α×Dβ, where I and D are the mean intensity and total duration of rainfall, and α and β are parameters estimated for a lower boundary curve to most or all the positive observations (i.e., landslide triggering rainfall events). This function does not account for the effect of antecedent precipitation as a conditioning factor for slope instability, an approach that may be adequate for global or regional thresholds that include landslides in surface geologies with a wide range of subsurface drainage conditions and pore-pressure responses to sustained rainfall. However, in a local scale and in geological settings dominated by a narrow range of drainage conditions and behaviours of pore-pressure response, the inclusion of antecedent precipitation in the definition of thresholds becomes necessary in order to ensure their optimum performance, especially when used as part of early warning systems (i.e., false alarms and missed events must be kept to a minimum). Some authors have incorporated the effect of antecedent rainfall in a discrete manner by first comparing the accumulated precipitation during a specified number of days against a reference value and then using a Caine's function threshold only when that reference value is exceeded. The approach in other authors has been to calculate threshold values as linear combinations of several triggering and antecedent parameters. The present study is aimed to proposing a new threshold function based on a generalisation of Caine's power law. The proposed function has the form I = (α1×Anα2)×Dβ, where I and D are defined as previously. The expression in parentheses is equivalent to Caine's α parameter. α1, α2 and β are parameters estimated for the threshold. An is the n-days cumulative rainfall. The suggested procedure to estimate the threshold is as follows: (1) Given N storms, assign one of the following flags to each storm: nL (non-triggering storms), yL (triggering storms), uL (uncertain-triggering storms). Successful predictions correspond to nL and yL storms occurring below and above the threshold, respectively. Storms flagged as uL are actually assigned either an nL or yL flag using a randomization procedure. (2) Establish a set of values of ni (e.g. 1, 4, 7, 10, 15 days, etc.) to test for accumulated precipitation. (3) For each storm and each ni value, obtain the antecedent accumulated precipitation in ni days Ani. (4) Generate a 3D grid of values of α1, α2 and β. (5) For a certain value of ni, generate confusion matrices for the N storms at each grid point and estimate an evaluation metrics parameter EMP (e.g., accuracy, specificity, etc.). (6) Repeat the previous step for all the set of ni values. (7) From the 3D grid corresponding to each ni value, search for the optimum grid point EMPopti(global minimum or maximum parameter). (8) Search for the optimum value of ni in the space ni vs EMPopti . (9) The threshold is defined by the value of ni obtained in the previous step and the corresponding values of α1, α2 and β. The procedure is illustrated using rainfall data and landslide observations from the San Salvador volcano, where a rainfall-triggered debris flow destroyed a neighbourhood in the capital city of El Salvador in 19 September, 1982, killing not less than 300 people.

  6. Self tuning system for industrial surveillance

    DOEpatents

    Stephan, Wegerich W; Jarman, Kristin K.; Gross, Kenneth C.

    2000-01-01

    A method and system for automatically establishing operational parameters of a statistical surveillance system. The method and system performs a frequency domain transition on time dependent data, a first Fourier composite is formed, serial correlation is removed, a series of Gaussian whiteness tests are performed along with an autocorrelation test, Fourier coefficients are stored and a second Fourier composite is formed. Pseudorandom noise is added, a Monte Carlo simulation is performed to establish SPRT missed alarm probabilities and tested with a synthesized signal. A false alarm test is then emperically evaluated and if less than a desired target value, then SPRT probabilities are used for performing surveillance.

  7. A laboratory evaluation of modified asphalt : final report.

    DOT National Transportation Integrated Search

    1981-01-01

    Quality aggregate availability in southern Louisiana has reached an alarmingly low level, while naturally occurring materials (sands) have been ignored due to their poor structural properties. Recent research reported by Chem-Crete Corporation indica...

  8. Priority coding for control room alarms

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    Indicating the priority of a spatially fixed, activated alarm tile on an alarm tile array by a shape coding at the tile, and preferably using the same shape coding wherever the same alarm condition is indicated elsewhere in the control room. The status of an alarm tile can change automatically or by operator acknowledgement, but tones and/or flashing cues continue to provide status information to the operator.

  9. Predictive Coding or Evidence Accumulation? False Inference and Neuronal Fluctuations

    PubMed Central

    Friston, Karl J.; Kleinschmidt, Andreas

    2010-01-01

    Perceptual decisions can be made when sensory input affords an inference about what generated that input. Here, we report findings from two independent perceptual experiments conducted during functional magnetic resonance imaging (fMRI) with a sparse event-related design. The first experiment, in the visual modality, involved forced-choice discrimination of coherence in random dot kinematograms that contained either subliminal or periliminal motion coherence. The second experiment, in the auditory domain, involved free response detection of (non-semantic) near-threshold acoustic stimuli. We analysed fluctuations in ongoing neural activity, as indexed by fMRI, and found that neuronal activity in sensory areas (extrastriate visual and early auditory cortex) biases perceptual decisions towards correct inference and not towards a specific percept. Hits (detection of near-threshold stimuli) were preceded by significantly higher activity than both misses of identical stimuli or false alarms, in which percepts arise in the absence of appropriate sensory input. In accord with predictive coding models and the free-energy principle, this observation suggests that cortical activity in sensory brain areas reflects the precision of prediction errors and not just the sensory evidence or prediction errors per se. PMID:20369004

  10. The Recognizability and Localizability of Auditory Alarms: Setting Global Medical Device Standards.

    PubMed

    Edworthy, Judy; Reid, Scott; McDougall, Siné; Edworthy, Jonathan; Hall, Stephanie; Bennett, Danielle; Khan, James; Pye, Ellen

    2017-11-01

    Objective Four sets of eight audible alarms matching the functions specified in IEC 60601-1-8 were designed using known principles from auditory cognition with the intention that they would be more recognizable and localizable than those currently specified in the standard. Background The audible alarms associated with IEC 60601-1-8, a global medical device standard, are known to be difficult to learn and retain, and there have been many calls to update them. There are known principles of design and cognition that might form the basis of more readily recognizable alarms. There is also scope for improvement in the localizability of the existing alarms. Method Four alternative sets of alarms matched to the functions specified in IEC 60601-1-8 were tested for recognizability and localizability and compared with the alarms currently specified in the standard. Results With a single exception, all prototype sets of alarms outperformed the current IEC set on both recognizability and localizability. Within the prototype sets, auditory icons were the most easily recognized, but the other sets, using word rhythms and simple acoustic metaphors, were also more easily recognized than the current alarms. With the exception of one set, all prototype sets were also easier to localize. Conclusion Known auditory cognition and perception principles were successfully applied to an existing audible alarm problem. Application This work constitutes the first (benchmarking) phase of replacing the alarms currently specified in the standard. The design principles used for each set demonstrate the relative ease with which different alarm types can be recognized and localized.

  11. Algorithm of reducing the false positives in IDS based on correlation Analysis

    NASA Astrophysics Data System (ADS)

    Liu, Jianyi; Li, Sida; Zhang, Ru

    2018-03-01

    This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.

  12. "Invisible" Killer

    MedlinePlus

    ... allow CO to come indoors. In addition, install battery-operated CO alarms or plug-in CO alarms with battery back-up in your home. Every home should ... Test your CO alarms frequently and replace dead batteries. A CO alarm can provide added protection, but ...

  13. Prevention of deaths and injuries caused by house fires: survey of local authority smoke alarm policies.

    PubMed

    Rowland, Diane; Afolabi, Elizabeth; Roberts, Ian

    2002-09-01

    Despite an increased risk of fire in disadvantaged households, smoke alarm ownership is considerably lower than in the general population. The government currently recommends that local authorities install battery-operated smoke alarms in all public sector properties regardless of tenure. However, the extent to which local authorities comply is currently not known. We conducted a survey of local authorities to establish the extent of their smoke alarm provision to public sector households. A telephone survey of all 405 local authorities within England and Wales was carried out. We obtained responses from 390 (97 per cent) local authorities, 266 of which had responsibility for housing. Over half of all public-sector households are offered smoke alarms by the local authorities. The majority of local authorities offer ionization and/or optical sensor alarm types (78 per cent), with many local authorities providing battery-operated alarms alone (17 per cent) or in combination with hardwired alarms (31 per cent). Many local authorities offer smoke alarm provision to their public-sector households. Whether this represents an effective and cost-effective use of resources requires further investigation.

  14. Residential smoke alarms and fire escape plans.

    PubMed

    Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F

    1998-01-01

    To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household.

  15. Using behavioral science to improve fire escape behaviors in response to a smoke alarm.

    PubMed

    Thompson, N J; Waterman, M B; Sleet, D A

    2004-01-01

    Although the likelihood of fire-related death in homes with smoke alarms is about one-half that in homes without alarms, alarm effectiveness is limited by behavior. Only 16% of residents of homes with alarms have developed and practiced plans for escape when the alarm sounds. We reviewed literature to identify behavioral constructs that influence smoke alarm use. We then convened experts in the behavioral aspects of smoke alarms who reviewed the constructs and determined that the appropriate areas for behavioral focus were formulating, practicing, and implementing escape plans should an alarm sound. They subsequently identified important behaviors to be addressed by burn-prevention programs and incorporated the constructs into a behavioral model for use in such programs. Finally, we organized the available literature to support this model and make programmatic recommendations. Many gaps remain in behavioral research to improve fire escape planning and practice. Future research must select the target behavior, apply behavioral theories, and distinguish between initiation and maintenance of behaviors associated with planning, practicing, and implementing home fire escape plans.

  16. Residential smoke alarms and fire escape plans.

    PubMed Central

    Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F

    1998-01-01

    OBJECTIVE: To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. METHODS: The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. RESULTS: Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. CONCLUSIONS: Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household. PMID:9769771

  17. Predicting potentially toxigenic Pseudo-nitzschia blooms in the Chesapeake Bay

    NASA Astrophysics Data System (ADS)

    Anderson, Clarissa R.; Sapiano, Mathew R. P.; Prasad, M. Bala Krishna; Long, Wen; Tango, Peter J.; Brown, Christopher W.; Murtugudde, Raghu

    2010-11-01

    Harmful algal blooms are now recognized as a significant threat to the Chesapeake Bay as they can severely compromise the economic viability of important recreational and commercial fisheries in the largest estuary of the United States. This study describes the development of empirical models for the potentially domoic acid-producing Pseudo-nitzschia species complex present in the Bay, developed from a 22-year time series of cell abundance and concurrent measurements of hydrographic and chemical properties. Using a logistic Generalized Linear Model (GLM) approach, model parameters and performance were compared over a range of Pseudo-nitzschia bloom thresholds relevant to toxin production by different species. Small-threshold blooms (≥10 cells mL -1) are explained by time of year, location, and variability in surface values of phosphate, temperature, nitrate plus nitrite, and freshwater discharge. Medium- (100 cells mL -1) to large- threshold (1000 cells mL -1) blooms are further explained by salinity, silicic acid, dissolved organic carbon, and light attenuation (Secchi) depth. These predictors are similar to other models for Pseudo-nitzschia blooms on the west coast, suggesting commonalities across ecosystems. Hindcasts of bloom probabilities at a 19% bloom prediction point yield a Heidke Skill Score of ~53%, a Probability of Detection ˜ 75%, a False Alarm Ratio of ˜ 52%, and a Probability of False Detection ˜9%. The implication of possible future changes in Baywide nutrient stoichiometry on Pseudo-nitzschia blooms is discussed.

  18. Receivers matter: the meaning of alarm calls and competition for nest sites in a bird community.

    PubMed

    Parejo, Deseada; Avilés, Jesús M; Expósito-Granados, Mónica

    2018-04-11

    Animal communities may constitute information networks where individuals gain information on predation risk by eavesdropping on alarm calls of other species. However, communities include species in different trophic levels, and it is not yet known how the trophic level of the receiver influences the informative value of a call. Furthermore, no empirical study has yet tested how increased competition may influence the value of alarm calls for distinct receivers. Here, we identify the importance of alarm calls emitted by a small owl, the little owl (Athene noctua), on the structure of a cavity-nesting bird community including mesopredators and primary prey under variable levels of competition for nest holes. Competitors sharing top predators with the callers and prey of the callers interpreted alarm and non-alarm calls differently. Competitors chose preferentially alarm and non-alarm patches over control patches to breed, while prey selected alarm patches. In contrast, competition for nest sites affected habitat selection of prey species more than that of competitors of the callers. This study provides support for a changing value of alarm calls and competition for nest sites for distinct receivers related to niche overlapping among callers and eavesdroppers, therefore, calling attention to possible cascading effects by the use of information in natural communities.

  19. A tradeoff between the losses caused by computer viruses and the risk of the manpower shortage

    PubMed Central

    Bi, Jichao; Yang, Lu-Xing; Wu, Yingbo; Tang, Yuan Yan

    2018-01-01

    This article addresses the tradeoff between the losses caused by a new virus and the size of the team for developing an antivirus against the virus. First, an individual-level virus spreading model is proposed to capture the spreading process of the virus before the appearance of its natural enemy. On this basis, the tradeoff problem is modeled as a discrete optimization problem. Next, the influences of different factors, including the infection force, the infection function, the available manpower, the alarm threshold, the antivirus development effort and the network topology, on the optimal team size are examined through computer simulations. This work takes the first step toward the tradeoff problem, and the findings are instructive to the decision makers of network security companies. PMID:29370222

  20. Monitoring Architectural Heritage by Wireless Sensors Networks: San Gimignano — A Case Study

    PubMed Central

    Mecocci, Alessandro; Abrardo, Andrea

    2014-01-01

    This paper describes a wireless sensor network (WSN) used to monitor the health state of architectural heritage in real-time. The WSN has been deployed and tested on the “Rognosa” tower in the medieval village of San Gimignano, Tuscany, Italy. This technology, being non-invasive, mimetic, and long lasting, is particularly well suited for long term monitoring and on-line diagnosis of the conservation state of heritage buildings. The proposed monitoring system comprises radio-equipped nodes linked to suitable sensors capable of monitoring crucial parameters like: temperature, humidity, masonry cracks, pouring rain, and visual light. The access to data is granted by a user interface for remote control. The WSN can autonomously send remote alarms when predefined thresholds are reached. PMID:24394600

  1. Estimation of the Scatterer Distribution of the Cirrhotic Liver using Ultrasonic Image

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Tadashi; Hachiya, Hiroyuki

    1998-05-01

    In the B-mode image of the liver obtained by an ultrasonic imaging system, the speckled pattern changes with the progression of the disease such as liver cirrhosis.In this paper we present the statistical characteristics of the echo envelope of the liver, and the technique to extract information of the scatterer distribution from the normal and cirrhotic liver images using constant false alarm rate (CFAR) processing.We analyze the relationship between the extracted scatterer distribution and the stage of liver cirrhosis. The ratio of the area in which the amplitude of the processing signal is more than the threshold to the entire processed image area is related quantitatively to the stage of liver cirrhosis.It is found that the proposed technique is valid for the quantitative diagnosis of liver cirrhosis.

  2. Remote shock sensing and notification system

    DOEpatents

    Muralidharan, Govindarajan [Knoxville, TN; Britton, Charles L [Alcoa, TN; Pearce, James [Lenoir City, TN; Jagadish, Usha [Knoxville, TN; Sikka, Vinod K [Oak Ridge, TN

    2010-11-02

    A low-power shock sensing system includes at least one shock sensor physically coupled to a chemical storage tank to be monitored for impacts, and an RF transmitter which is in a low-power idle state in the absence of a triggering signal. The system includes interface circuitry including or activated by the shock sensor, wherein an output of the interface circuitry is coupled to an input of the RF transmitter. The interface circuitry triggers the RF transmitter with the triggering signal to transmit an alarm message to at least one remote location when the sensor senses a shock greater than a predetermined threshold. In one embodiment the shock sensor is a shock switch which provides an open and a closed state, the open state being a low power idle state.

  3. Remote shock sensing and notification system

    DOEpatents

    Muralidharan, Govindarajan; Britton, Charles L.; Pearce, James; Jagadish, Usha; Sikka, Vinod K.

    2008-11-11

    A low-power shock sensing system includes at least one shock sensor physically coupled to a chemical storage tank to be monitored for impacts, and an RF transmitter which is in a low-power idle state in the absence of a triggering signal. The system includes interference circuitry including or activated by the shock sensor, wherein an output of the interface circuitry is coupled to an input of the RF transmitter. The interface circuitry triggers the RF transmitting with the triggering signal to transmit an alarm message to at least one remote location when the sensor senses a shock greater than a predetermined threshold. In one embodiment the shock sensor is a shock switch which provides an open and a closed state, the open state being a low power idle state.

  4. A tradeoff between the losses caused by computer viruses and the risk of the manpower shortage.

    PubMed

    Bi, Jichao; Yang, Lu-Xing; Yang, Xiaofan; Wu, Yingbo; Tang, Yuan Yan

    2018-01-01

    This article addresses the tradeoff between the losses caused by a new virus and the size of the team for developing an antivirus against the virus. First, an individual-level virus spreading model is proposed to capture the spreading process of the virus before the appearance of its natural enemy. On this basis, the tradeoff problem is modeled as a discrete optimization problem. Next, the influences of different factors, including the infection force, the infection function, the available manpower, the alarm threshold, the antivirus development effort and the network topology, on the optimal team size are examined through computer simulations. This work takes the first step toward the tradeoff problem, and the findings are instructive to the decision makers of network security companies.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Sean R.; Walter, William R.

    Seismic waveform correlation offers the prospect of greatly reducing event detection thresholds when compared with more conventional processing methods. Correlation is applicable for seismic events that in some sense repeat, that is they have very similar waveforms. A number of recent studies have shown that correlated seismic signals may form a significant fraction of seismicity at regional distances. For the particular case of multiple nuclear explosions at the same test site, regional distance correlation also allows very precise relative location measurements and could offer the potential to lower thresholds when multiple events exist. Using the Comprehensive Nuclear-Test-Ban Treaty (CTBT) Internationalmore » Monitoring System (IMS) seismic array at Matsushiro, Japan (MJAR), Gibbons and Ringdal (2012) were able to create a multichannel correlation detector with a very low false alarm rate and a threshold below magnitude 3.0. They did this using the 2006 or 2009 Democratic People’s Republic of Korea (DPRK) nuclear explosion as a template to search through a data stream from the same station to find a match via waveform correlation. In this paper, we extend the work of Gibbons and Ringdal (2012) and measure the correlation detection threshold at several other IMS arrays. We use this to address three main points. First, we show the IMS array station at Mina, Nevada (NVAR), which is closest to the Nevada National Security Site (NNSS), is able to detect a chemical explosion that is well under 1 ton with the right template. Second, we examine the two IMS arrays closest to the North Korean (DPRK) test site (at Ussuriysk, Russian Federation [USRK] and Wonju, Republic of Korea [KSRS]) to show that similarly low thresholds are possible when the right templates exist. We also extend the work of Schaff et al. (2012) and measure the correlation detection threshold at the nearest Global Seismic Network (GSN) three-component station (MDJ) at Mudanjiang, Heilongjiang Province, China, from the New China Digital Seismograph Network (IC). To conclude, we use these results to explore the recent claim by Zhang and Wen (2015) that the DPRK conducted “…a low-yield nuclear test…” on 12 May 2010.« less

  6. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4360 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm...

  7. Estimating alarm thresholds and the number of components in mixture distributions

    NASA Astrophysics Data System (ADS)

    Burr, Tom; Hamada, Michael S.

    2012-09-01

    Mixtures of probability distributions arise in many nuclear assay and forensic applications, including nuclear weapon detection, neutron multiplicity counting, and in solution monitoring (SM) for nuclear safeguards. SM data is increasingly used to enhance nuclear safeguards in aqueous reprocessing facilities having plutonium in solution form in many tanks. This paper provides background for mixture probability distributions and then focuses on mixtures arising in SM data. SM data can be analyzed by evaluating transfer-mode residuals defined as tank-to-tank transfer differences, and wait-mode residuals defined as changes during non-transfer modes. A previous paper investigated impacts on transfer-mode and wait-mode residuals of event marking errors which arise when the estimated start and/or stop times of tank events such as transfers are somewhat different from the true start and/or stop times. Event marking errors contribute to non-Gaussian behavior and larger variation than predicted on the basis of individual tank calibration studies. This paper illustrates evidence for mixture probability distributions arising from such event marking errors and from effects such as condensation or evaporation during non-transfer modes, and pump carryover during transfer modes. A quantitative assessment of the sample size required to adequately characterize a mixture probability distribution arising in any context is included.

  8. A vector-based failure detection and isolation algorithm for a dual fail-operational redundant strapdown inertial measurement unit

    NASA Technical Reports Server (NTRS)

    Morrell, Frederick R.; Bailey, Melvin L.

    1987-01-01

    A vector-based failure detection and isolation technique for a skewed array of two degree-of-freedom inertial sensors is developed. Failure detection is based on comparison of parity equations with a threshold, and isolation is based on comparison of logic variables which are keyed to pass/fail results of the parity test. A multi-level approach to failure detection is used to ensure adequate coverage for the flight control, display, and navigation avionics functions. Sensor error models are introduced to expose the susceptibility of the parity equations to sensor errors and physical separation effects. The algorithm is evaluated in a simulation of a commercial transport operating in a range of light to severe turbulence environments. A bias-jump failure level of 0.2 deg/hr was detected and isolated properly in the light and moderate turbulence environments, but not detected in the extreme turbulence environment. An accelerometer bias-jump failure level of 1.5 milli-g was detected over all turbulence environments. For both types of inertial sensor, hard-over, and null type failures were detected in all environments without incident. The algorithm functioned without false alarm or isolation over all turbulence environments for the runs tested.

  9. Evaluation of Motorcycle Safety in Kansas : Technical Summary

    DOT National Transportation Integrated Search

    2012-01-01

    Over the past several years, motorcycle fatalities have increased at an alarming rate in the United States. Motorcycle safety issues in Kansas are no different from the national scenario. Accordingly, this study attempted to investigate motorcycle cr...

  10. Evaluation of the overheight detection system effectiveness at Eklutna bridge.

    DOT National Transportation Integrated Search

    2013-03-01

    The Eklutna River/Glenn Highway bridge has sustained repeated impacts from overheight trucks. In 2006, ADOT&PF installed an : overheight vehicle warning system. The system includes laser detectors, alarms, and message boards. Since installation, pers...

  11. Evaluation of mobile work zone alarm systems.

    DOT National Transportation Integrated Search

    2014-06-01

    Maintenance of highways often involves mobile work zones for various types of low speed moving operations such as : striping and sweeping. The speed differential between the moving operation and traffic, and the increasing problem of : distracted dri...

  12. Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; Francucci, M.; Gaudio, P.; Gelfusa, M.; Martellucci, S.; Richetta, M.; Lo Feudo, T.

    2007-04-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.

  13. Clinically relevant hypoglycemia prediction metrics for event mitigation.

    PubMed

    Harvey, Rebecca A; Dassau, Eyal; Zisser, Howard C; Bevier, Wendy; Seborg, Dale E; Jovanovič, Lois; Doyle, Francis J

    2012-08-01

    The purpose of this study was to develop a method to compare hypoglycemia prediction algorithms and choose parameter settings for different applications, such as triggering insulin pump suspension or alerting for rescue carbohydrate treatment. Hypoglycemia prediction algorithms with different parameter settings were implemented on an ambulatory dataset containing 490 days from 30 subjects with type 1 diabetes mellitus using the Dexcom™ (San Diego, CA) SEVEN™ continuous glucose monitoring system. The performance was evaluated using a proposed set of metrics representing the true-positive ratio, false-positive rate, and distribution of warning times. A prospective, in silico study was performed to show the effect of using different parameter settings to prevent or rescue from hypoglycemia. The retrospective study results suggest the parameter settings for different methods of hypoglycemia mitigation. When rescue carbohydrates are used, a high true-positive ratio, a minimal false-positive rate, and alarms with short warning time are desired. These objectives were met with a 30-min prediction horizon and two successive flags required to alarm: 78% of events were detected with 3.0 false alarms/day and 66% probability of alarms occurring within 30 min of the event. This parameter setting selection was confirmed in silico: treating with rescue carbohydrates reduced the duration of hypoglycemia from 14.9% to 0.5%. However, for a different method, such as pump suspension, this parameter setting only reduced hypoglycemia to 8.7%, as can be expected by the low probability of alarming more than 30 min ahead. The proposed metrics allow direct comparison of hypoglycemia prediction algorithms and selection of parameter settings for different types of hypoglycemia mitigation, as shown in the prospective in silico study in which hypoglycemia was alerted or treated with rescue carbohydrates.

  14. Specific and non-specific symptoms of colorectal cancer and contact to general practice.

    PubMed

    Rasmussen, Sanne; Larsen, Pia V; Søndergaard, Jens; Elnegaard, Sandra; Svendsen, Rikke P; Jarbøl, Dorte E

    2015-08-01

    To improve survival rates for colorectal cancer, referral guidelines have been implemented. First step in the diagnostic process is for the individual to recognize the symptoms and contact his/her general practitioner (GP) for evaluation. To determine (i) the prevalence of specific and non-specific symptom experiences indicative of colorectal cancer, (ii) the proportion of subsequent contacts to GPs, (iii) to explore the possible differences in symptom experience and contact to GPs between age and sex. A nationwide study of 100000 adults, aged 20 years and older, were randomly selected in the general population and invited to participate in an internet-based survey. Items regarding experience of specific and non-specific alarm symptoms of colorectal cancer within the preceding 4 weeks and contact to GP were included. A total of 49706 subjects completed the questionnaire. Abdominal pain was the most common specific alarm symptom (19.7%) and tiredness was the most common non-specific symptom (49.8%). The experiences of symptoms were more common among women and more common in the youngest age groups for both sexes. The symptom leading to the highest proportion of GP contacts was rectal bleeding (33.8%). When experiencing any combination of two specific alarm symptoms, the proportion who contacted a GP was less than 50%. The combination of a non-specific and a specific alarm symptom gave rise to the highest proportion of GP contacts. Although specific and non-specific alarm symptoms of colorectal cancer are common in the general population, the proportion of GP contacts is low. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Development and Application of a Clinical Microsystem Simulation Methodology for Human Factors-Based Research of Alarm Fatigue.

    PubMed

    Kobayashi, Leo; Gosbee, John W; Merck, Derek L

    2017-07-01

    (1) To develop a clinical microsystem simulation methodology for alarm fatigue research with a human factors engineering (HFE) assessment framework and (2) to explore its application to the comparative examination of different approaches to patient monitoring and provider notification. Problems with the design, implementation, and real-world use of patient monitoring systems result in alarm fatigue. A multidisciplinary team is developing an open-source tool kit to promote bedside informatics research and mitigate alarm fatigue. Simulation, HFE, and computer science experts created a novel simulation methodology to study alarm fatigue. Featuring multiple interconnected simulated patient scenarios with scripted timeline, "distractor" patient care tasks, and triggered true and false alarms, the methodology incorporated objective metrics to assess provider and system performance. Developed materials were implemented during institutional review board-approved study sessions that assessed and compared an experimental multiparametric alerting system with a standard monitor telemetry system for subject response, use characteristics, and end-user feedback. A four-patient simulation setup featuring objective metrics for participant task-related performance and response to alarms was developed along with accompanying structured HFE assessment (questionnaire and interview) for monitor systems use testing. Two pilot and four study sessions with individual nurse subjects elicited true alarm and false alarm responses (including diversion from assigned tasks) as well as nonresponses to true alarms. In-simulation observation and subject questionnaires were used to test the experimental system's approach to suppressing false alarms and alerting providers. A novel investigative methodology applied simulation and HFE techniques to replicate and study alarm fatigue in controlled settings for systems assessment and experimental research purposes.

  16. Development of snake-directed antipredator behavior by wild white-faced capuchin monkeys: II. Influence of the social environment.

    PubMed

    Meno, Whitney; Coss, Richard G; Perry, Susan

    2013-03-01

    Young animals are known to direct alarm calls at a wider range of animals than adults. If social cues are safer and/or more reliable to use than asocial cues for learning about predators, then it is expected that the development of this behavior will be affected by the social environment. Our study examined the influence of the social environment on antipredator behavior in infant, juvenile, and adult wild white-faced capuchin monkeys (Cebus capucinus) at Lomas Barbudal Biological Reserve in Costa Rica during presentations of different species of model snakes and novel models. We examined (a) the alarm calling behavior of the focal animal when alone versus in the vicinity of conspecific alarm callers and (b) the latency of conspecifics to alarm call once the focal animal alarm called. Focal animals alarm called more when alone than after hearing a conspecific alarm call. No reliable differences were found in the latencies of conspecifics to alarm call based on age or model type. Conspecifics were more likely to alarm call when focal individuals alarm called at snake models than when they alarm called at novel models. Results indicate (a) that alarm calling may serve to attract others to the predator's location and (b) that learning about specific predators may begin with a generalized response to a wide variety of species, including some nonthreatening ones, that is winnowed down via Pavlovian conditioned inhibition into a response directed toward specific dangerous species. This study reveals that conspecifics play a role in the development of antipredator behavior in white-faced capuchins. © 2012 Wiley Periodicals, Inc.

  17. Smoke alarm installation and function in inner London council housing.

    PubMed

    DiGuiseppi, C; Roberts, I; Speirs, N

    1999-11-01

    To determine the prevalence of and predictors for installed, functioning smoke alarms in council (public) housing in a low income, multi-ethnic urban area. Cross sectional study. 40 materially deprived electoral wards in two inner London boroughs. Occupants of 315 addresses randomly selected from council housing lists, with 75% response rate. Installation and function of smoke alarms based on inspection and testing. 39% (95% confidence interval (CI) 33% to 46%) of council tenants owned a smoke alarm, 31% (95% CI 25% to 38%) had an installed alarm (of which 54% were correctly installed), and 16% (95% CI 12% to 22%) had at least one installed, functioning alarm. Alarms most commonly failed because they lacked batteries (72%). In multivariate modelling, having an installed, functioning alarm was most strongly associated with living in a house versus a flat (apartment) (odds ratio (OR) 3.2, 95% CI 1.1 to 10.0), having two resident adults versus one (OR 2.8, 95% CI 1.2 to 6.5), and recognising stills from a Home Office television smoke alarm campaign (OR 2.4, 95% CI 1.1 to 5.5). Fires are a leading cause of child injury and death, particularly among those younger than 5 years of age and those in social classes IV and V. Smoke alarms are associated with a significantly reduced risk of death in residential fires, and are more protective in households with young children. Few council properties in a multi-ethnic, materially deprived urban area had any installed, functioning smoke alarms, despite a high risk of residential fires and fire related injuries in such areas. Effective methods to increase the prevalence of installed and functioning alarms must be identified.

  18. Smoke alarm installation and function in inner London council housing

    PubMed Central

    DiGuiseppi, C.; Roberts, I.; Speirs, N.

    1999-01-01

    AIM—To determine the prevalence of and predictors for installed, functioning smoke alarms in council (public) housing in a low income, multi-ethnic urban area.
DESIGN—Cross sectional study.
SETTING—40 materially deprived electoral wards in two inner London boroughs.
PARTICIPANTS—Occupants of 315 addresses randomly selected from council housing lists, with 75% response rate.
MAIN OUTCOME MEASURES—Installation and function of smoke alarms based on inspection and testing.
RESULTS—39% (95% confidence interval (CI) 33% to 46%) of council tenants owned a smoke alarm, 31% (95% CI 25% to 38%) had an installed alarm (of which 54% were correctly installed), and 16% (95% CI 12% to 22%) had at least one installed, functioning alarm. Alarms most commonly failed because they lacked batteries (72%). In multivariate modelling, having an installed, functioning alarm was most strongly associated with living in a house versus a flat (apartment) (odds ratio (OR) 3.2, 95% CI 1.1 to 10.0), having two resident adults versus one (OR 2.8, 95% CI 1.2 to 6.5), and recognising stills from a Home Office television smoke alarm campaign (OR 2.4, 95% CI 1.1 to 5.5).
CONCLUSIONS—Fires are a leading cause of child injury and death, particularly among those younger than 5 years of age and those in social classes IV and V. Smoke alarms are associated with a significantly reduced risk of death in residential fires, and are more protective in households with young children. Few council properties in a multi-ethnic, materially deprived urban area had any installed, functioning smoke alarms, despite a high risk of residential fires and fire related injuries in such areas. Effective methods to increase the prevalence of installed and functioning alarms must be identified.

 PMID:10519711

  19. The acute physiological stress response to an emergency alarm and mobilization during the day and at night.

    PubMed

    Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C

    2016-01-01

    The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F(20,442) = 9.140, P < 0.001) and night (F(23,459) = 8.356, P < 0.001) alarm conditions compared to the respective control conditions. There was no difference in saliva cortisol between day alarm and day control conditions. Cortisol was higher (F(6,183) = 2.450, P < 0.001) following the night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F(6,174) = 4.071, P < 0.001) than the magnitude of difference between the day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants' ability to interpret the alarm when sleeping versus when awake.

  20. The acute physiological stress response to an emergency alarm and mobilization during the day and at night

    PubMed Central

    Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C

    2016-01-01

    The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F20,442 = 9.140, P < 0.001) and night (F23,459 = 8.356, P < 0.001) alarm conditions compared to the respective control conditions. There was no difference in saliva cortisol between day alarm and day control conditions. Cortisol was higher (F6,183 = 2.450, P < 0.001) following the night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F6,174 = 4.071, P < 0.001) than the magnitude of difference between the day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants’ ability to interpret the alarm when sleeping versus when awake. PMID:27157688

  1. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...

  2. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...

  3. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...

  4. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...

  5. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the... telephones. The employer shall post emergency telephone numbers near telephones, or employee notice boards... operating condition as promptly as possible after each test or alarm. Spare alarm devices and components...

  6. Effect of vibratory soldier alarm signals on the foraging behavior of subterranean termites (Isoptera: Rhinotermitidae).

    PubMed

    Inta, R; Evans, T A; Lai, J C S

    2009-02-01

    Termite soldiers produce a vibratory alarm signal to warn conspecific workers. This study recorded and characterized the alarm signals of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae) and then investigated the effect of playing these recorded alarm signals on C. acinaciformis feeding activity. Foraging groups of termites were offered paired wooden blocks: either one block, continuously stimulated with a vibratory alarm signal, paired with a nonstimulated block (the alarm treatment), continuously stimulated with a pink noise signal, paired with a nonstimulated block (control for nonspecific vibrations) or two nonstimulated blocks (control for environmental effects), for 4 wk. The amount of wood eaten in the blocks stimulated by the alarm signals was significantly less than the paired nonstimulated blocks, while there seemed to be no preference in the case of the pink noise playback or control for direction. Importantly, the termites seemed not to have adapted to the recorded alarm signal over the 4-wk duration of the experiment, unlike previous studies using nonbiologically derived signals.

  7. Interevent times in a new alarm-based earthquake forecasting model

    NASA Astrophysics Data System (ADS)

    Talbi, Abdelhak; Nanjo, Kazuyoshi; Zhuang, Jiancang; Satake, Kenji; Hamdache, Mohamed

    2013-09-01

    This study introduces a new earthquake forecasting model that uses the moment ratio (MR) of the first to second order moments of earthquake interevent times as a precursory alarm index to forecast large earthquake events. This MR model is based on the idea that the MR is associated with anomalous long-term changes in background seismicity prior to large earthquake events. In a given region, the MR statistic is defined as the inverse of the index of dispersion or Fano factor, with MR values (or scores) providing a biased estimate of the relative regional frequency of background events, here termed the background fraction. To test the forecasting performance of this proposed MR model, a composite Japan-wide earthquake catalogue for the years between 679 and 2012 was compiled using the Japan Meteorological Agency catalogue for the period between 1923 and 2012, and the Utsu historical seismicity records between 679 and 1922. MR values were estimated by sampling interevent times from events with magnitude M ≥ 6 using an earthquake random sampling (ERS) algorithm developed during previous research. Three retrospective tests of M ≥ 7 target earthquakes were undertaken to evaluate the long-, intermediate- and short-term performance of MR forecasting, using mainly Molchan diagrams and optimal spatial maps obtained by minimizing forecasting error defined by miss and alarm rate addition. This testing indicates that the MR forecasting technique performs well at long-, intermediate- and short-term. The MR maps produced during long-term testing indicate significant alarm levels before 15 of the 18 shallow earthquakes within the testing region during the past two decades, with an alarm region covering about 20 per cent (alarm rate) of the testing region. The number of shallow events missed by forecasting was reduced by about 60 per cent after using the MR method instead of the relative intensity (RI) forecasting method. At short term, our model succeeded in forecasting the occurrence region of the 2011 Mw 9.0 Tohoku earthquake, whereas the RI method did not. Cases where a period of quiescent seismicity occurred before the target event often lead to low MR scores, meaning that the target event was not predicted and indicating that our model could be further improved by taking into account quiescent periods in the alarm strategy.

  8. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  9. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  10. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  11. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  12. 46 CFR 113.27-1 - Engineers' assistance-needed alarm.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...

  13. 46 CFR 113.27-1 - Engineers' assistance-needed alarm.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...

  14. 46 CFR 113.27-1 - Engineers' assistance-needed alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...

  15. 46 CFR 113.27-1 - Engineers' assistance-needed alarm.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...

  16. 46 CFR 113.27-1 - Engineers' assistance-needed alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Engineers' assistance-needed alarm. 113.27-1 Section 113.27-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Engineers' Assistance-Needed Alarm § 113.27-1 Engineers...

  17. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...

  18. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...

  19. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...

  20. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...

  1. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND... sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart 76...

  2. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...

  3. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...

  4. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...

  5. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...

  6. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  7. Tactical Sensors for Dispersed TNF (Tactical Nuclear Force) Units. Appendix 1.Tactical Sensory Survey.

    DTIC Science & Technology

    1983-06-30

    activating a separate transmitter, audible alarm, or contact closure. This sensor is compatible with any device that utilizes an input pulse or...transmitter, audible alarm, or contact closure. This sensor is compatible *i with any device that utilizes an output to produce an alarm. 110-4769-002. This...used to generate an alarm by activating a separate transmitter, audible alarm, or contact closure. This sensor is compatible with any device that

  8. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...

  9. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...

  10. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...

  11. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...

  12. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. (a) Labeling. Each smoke alarm required under paragraph (b) of this section must conform with the...

  13. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. (a) Labeling. Each smoke alarm required under paragraph (b) of this section must conform with the...

  14. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. (a) Labeling. Each smoke alarm required under paragraph (b) of this section must conform with the...

  15. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarm requirements. 3280.208... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.208 Smoke alarm requirements. Link to an amendment published at 78 FR 73982, Dec. 9, 2013. (a) Labeling. Each smoke alarm...

  16. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  17. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  18. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  19. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  20. 46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...

Top