EVALUATING COMMERCIALLY AVAILABLE DERMAL ...
As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues. One concern involves the materials in wipes used to collect pesticide residues or other contact materials on the skin. In recent studies (e.g., National Human Exposure Assessment Survey; NHEXAS), isopropyl alcohol has been used as a solvent in conjunction with a cloth wipe to obtain samples from the hands of adults and children. Although isopropyl alcohol is generally considered innocuous, the use of commercially available products could eliminate concerns about exposure to alcohol. A few studies have evaluated the potential of commercially available baby wipes to collect personal exposure samples for metals research, but not for the area of pesticide research (Millson et al., 1994; Campbell et al., 1993; Lichtenwalner et al., 1993). Therefore, there is a need to evaluate the potential for using commercially available baby wipes for collecting pesticide samples from skin and other surfaces. Another concern involves establishing a convenient and safe method for assessing overall dermal exposure for children, especially for those in crawling stage. One route that the U .S. Environmental Protection Agency (EPA) would like to investigate is the use of cotton body suits (infant sleepers) as an indicator
Saha, Avinandan; Botha, Stefan Louis; Weaving, Paul; Satta, Giovanni
2016-11-01
Peracetic acid sporicidal wipes have been shown to be an effective disinfectant, but in controlled test environments. Their high cost may restrict use. This pilot study investigated the efficacy and compared the costs of routine universal use of peracetic acid sporicidal wipes versus sporicidal quaternary ammonium compound and alcohol wipes in the disinfection of a hospital environment. The routine universal use of peracetic acid wipes (Clinell Sporicidal; GAMA Healthcare Ltd, London, UK) was allocated to a study ward, whereas the control ward continued with the use of quaternary ammonium compound wipes (Tuffie 5; Vernacare, Bolton, UK) and alcohol wipes (PDI Sani-Cloth 70; PDI, Flint, UK). Twenty high-touch areas in the 2 wards were sampled for the presence of indicator organisms. The weekly detection rates of indicator organisms and weekly healthcare associated infection (HCAI) rates in the 2 wards were compared and examined for decreasing trends over the trial period. The detection rates of indicator organisms and HCAI rates were not significantly different in the 2 wards, and did not decrease significantly over the trial period. However, the peracetic acid wipes seem to be more effective against gram-negative organisms but at a significantly higher cost. Further prospective studies are needed to assess the cost-effectiveness of peracetic acid wipes. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
D'Antonio, Natalie N; Rihs, John D; Stout, Janet E; Yu, Victor L
2010-11-01
The Centers for Disease Control and Prevention's guidelines for hand hygiene state that the use of alcohol-based hand wipes is not an effective substitute for the use of an alcohol-based hand rub or handwashing with an antimicrobial soap and water. The objective of this study was to determine whether a hand wipe with higher ethanol content (65.9%) is as effective as an ethanol hand rub or antimicrobial soap in removing bacteria and spores from hands. In two separate experiments, the hands of 7 subjects were inoculated with a suspension of Serratia marcescens or Geobacillus stearothermophilus. Subjects washed with each of 3 different products: 65.9% ethanol hand wipes (Sani-Hands ALC), 62% ethanol gel rub (Purell), and antimicrobial soap containing 0.75% triclosan (Kindest Kare). A total of 56 observations were analyzed for S marcescens removal and 70 observations were analyzed for G stearothermophilus removal. The rank order of product efficacy for both bacteria and spore removal was antibacterial soap > 65.9% ethanol hand wipes >62% ethanol hand rub. Mean S marcescens log reductions (±SD) for the 65.9% ethanol alcohol wipe, 62% ethanol alcohol rub, and antimicrobial foam soap were 3.44 ± 0.847, 2.32 ± 1.065, and 4.44 ± 1.018, respectively (P < .001). Mean G stearothermophilus log reductions for the 65.9% ethanol wipe, 62% ethanol rub, and antimicrobial foam soap were 0.51 ± 0.26, -0.8 ± 0.32 increase over baseline, and 1.72 ± 0.62, respectively (P < .001). The alcohol-based hand wipe containing 65.9% ethanol was significantly more effective than the 62% ethanol rub in reducing the number of viable bacteria and spores on the hands. Copyright © 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Terra Firma-Forme Dermatosis in Singaporean Patients: The "Alcohol Wipe" Sign.
Oh, Choon Chiat; Oon, Hazel H; Ng, See Ket; Tee, Shang Ian; Jhingan, Anjali; Chong, Wei-Sheng
2016-01-01
The term terra firma-forme dermatosis arises from the Latin phrase terra firma , meaning dry land (dirt), thus implying dirt-like dermatosis. The authors highlight five cases of patients with terra firma-forme dermatosis presenting to our dermatology center between 2012 and 2013. All patients presented to the dermatologist for persistent reticulated brown patches on the skin. These patients ranged in age from 6 to 22 years. All patients had tried various cleansing soaps and agents but were unable to remove the patches. The condition was cosmetically unacceptable to the patients and parents. Clinically, these patients had reticulated brown patches. Rubbing 70% isopropyl alcohol wipes on the affected areas demonstrated clearance of the brown pigmented patches in all cases. The diagnosis of terra firma-forme dermatosis (TFFD) was confirmed by forceful rubbing with a gauze pad immersed in 70% isopropyl alcohol or ethyl alcohol. Patients should be reassured about the benign nature of TFFD and educated about the cleaning procedure. Recognition of this condition can assist physicians in making a diagnosis and therapy with a simple alcohol wipe, preventing further unnecessary tests for patients.
Lessons learned from surface wipe sampling for lead in three workplaces.
Beaucham, Catherine; Ceballos, Diana; King, Bradley
2017-08-01
Surface wipe sampling in the occupational environment is a technique widely used by industrial hygienists. Although several organizations have promulgated standards for sampling lead and other metals, uncertainty still exists when trying to determine an appropriate wipe sampling strategy and how to interpret sampling results. Investigators from the National Institute for Occupational Safety and Health (NIOSH) Health Hazard Evaluation Program have used surface wipe sampling as part of their exposure assessment sampling strategies in a wide range of workplaces. This article discusses wipe sampling for measuring lead on surfaces in three facilities: (1) a battery recycling facility; (2) a firing range and gun store; and (3) an electronic scrap recycling facility. We summarize our findings from the facilities and what we learned by integrating wipe sampling into our sampling plan. Wiping sampling demonstrated lead in non-production surfaces in all three workplaces and that the potential that employees were taking lead home to their families existed. We also found that the presence of metals such as tin can interfere with the colorimetric results. We also discuss the advantages and disadvantages of colorimetric analysis of surface wipe samples and the challenges we faced when interpreting wipe sampling results.
A LITERATURE REVIEW OF WIPE SAMPLING METHODS ...
Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerousmethods of wipe sampling exist, and each method has its own specification for the type of wipe, wetting solvent, and determinative step to be used, depending upon the contaminant of concern. The objective of this report is to concisely summarize the findings of a literature review that was conducted to identify the state-of-the-art wipe sampling techniques for a target list of compounds. This report describes the methods used to perform the literature review; a brief review of wipe sampling techniques in general; an analysis of physical and chemical properties of each target analyte; an analysis of wipe sampling techniques for the target analyte list; and asummary of the wipe sampling techniques for the target analyte list, including existing data gaps. In general, no overwhelming consensus can be drawn from the current literature on how to collect a wipe sample for the chemical warfare agents, organophosphate pesticides, and other toxic industrial chemicals of interest to this study. Different methods, media, and wetting solvents have been recommended and used by various groups and different studies. For many of the compounds of interest, no specific wipe sampling methodology has been established for their collection. Before a wipe sampling method (or methods) can be established for the co
Ceballos, Diana; King, Bradley; Beaucham, Catherine; Brueck, Scott E.
2015-01-01
Closed-face 37-millimeter (mm) polystyrene cassettes are often used for exposure monitoring of metal particulates. Several methods have been proposed to account for the wall loss in air sampling cassettes, including rinsing, wiping, within-cassette dissolution, and an internal capsule fused to the filter that could be digested with the filter. Until internal capsules replace filters, other methods for assessing wall losses may be considered. To determine if rinsing and wiping or wiping alone is adequate to determine wall losses on cassettes, we collected 54 full-shift area air samples at a battery recycling facility. We collected six replicate samples at three locations within the facility for 3 consecutive days. The wall losses of three replicate cassettes from each day-location were analyzed following a rinse and two consecutive wipes. The wall losses of the other three replicates from each day-location were analyzed following two consecutive wipes only. Mixed-cellulose ester membrane filter, rinse, and wipes were analyzed separately following NIOSH Method 7303. We found an average of 29% (range: 8%–54%) recovered lead from the cassette walls for all samples. We also found that rinsing prior to wiping the interior cassette walls did not substantially improve recovery of wall losses compared to wiping alone. A rinse plus one wipe recovered on average 23% (range: 13%–33%) of the lead, while one wipe alone recovered on average 21% (range: 16%–22%). Similarly we determined that a second wipe did not provide substantial additional recovery of lead (average: 4%, range: 0.4%–19%) compared to the first wipe disregarding the rinse (average: 18%, range: 4%–39%). We concluded that when an internal capsule is not used, wall losses of lead dust in air sampling cassettes can be adequately recovered by wiping the internal wall surfaces of the cassette with a single wipe. PMID:26125330
Wenzel, A; Kornum, F; Knudsen, MR; Lau, E Frandsen
2013-01-01
Objectives: To assess (1) antimicrobial efficiency of wiping intraoral phosphor plates with alcohol tissues based on ethanol or 2-propanol alcohols after contamination with Candida albicans and Streptococcus oralis, (2) a concept for autodisinfection with ultraviolet light of the transport ramp in a scanner for phosphor plates and (3) the impact of wiping with alcohol tissues on durability of the plate. Methods: Suspensions of C. albicans and S. oralis were prepared in concentrations of 109 and 105 organisms per ml, and Digora (Digora® Optime Imaging Plate, size 2; Soredex, PalaDEx Group Brenntag Nordic A/S, Hellerup, Denmark) and Vista (VistaScan® Imaging Plate PLUS, size 2; Dürr Dental AG, Bietigheim-Bissingen, Germany) plates were contaminated. The plates were wiped with ethanol or 2-propanol disinfectant tissues and imprints obtained on agar. Number of microbial colonies after culturing was recorded. The scanner ramp was contaminated with C. albicans or S. oralis, respectively, the ultraviolet light (UV light) disinfection in the scanner was activated and the number of colonies after culturing was recorded. Plates from each system were sequentially wiped (5–60 times) with ethanol and 2-propanol, exposed and scanned. 48 images from each system were scored blind: 1 = no artefact, 2 = small artefacts and 3 = severe artefacts. Results: Ethanol eliminated C. albicans and S. oralis in high and low concentrations from both types of plates, whereas 2-propanol did not eliminate all micro-organisms at high concentrations. The UV light eliminated all micro-organisms from the ramp. Ethanol degraded the plates to a larger extent than did 2-propanol. Images from Vista plates showed severe artefacts after wiping with ethanol; those from Digora plates did not. Conclusions: Ethanol eliminated all micro-organisms but degraded phosphor plates, whereas 2-propanol did not eliminate all micro-organisms and still degraded plates from Vista but not from Digora. PMID:23420856
Wenzel, A; Kornum, F; Knudsen, Mr; Lau, E Frandsen
2013-01-01
To assess (1) antimicrobial efficiency of wiping intraoral phosphor plates with alcohol tissues based on ethanol or 2-propanol alcohols after contamination with Candida albicans and Streptococcus oralis, (2) a concept for autodisinfection with ultraviolet light of the transport ramp in a scanner for phosphor plates and (3) the impact of wiping with alcohol tissues on durability of the plate. Suspensions of C. albicans and S. oralis were prepared in concentrations of 10(9) and 10(5) organisms per ml, and Digora (Digora(®) Optime Imaging Plate, size 2; Soredex, PalaDEx Group Brenntag Nordic A/S, Hellerup, Denmark) and Vista (VistaScan(®) Imaging Plate PLUS, size 2; Dürr Dental AG, Bietigheim-Bissingen, Germany) plates were contaminated. The plates were wiped with ethanol or 2-propanol disinfectant tissues and imprints obtained on agar. Number of microbial colonies after culturing was recorded. The scanner ramp was contaminated with C. albicans or S. oralis, respectively, the ultraviolet light (UV light) disinfection in the scanner was activated and the number of colonies after culturing was recorded. Plates from each system were sequentially wiped (5-60 times) with ethanol and 2-propanol, exposed and scanned. 48 images from each system were scored blind: 1 = no artefact, 2 = small artefacts and 3 = severe artefacts. Ethanol eliminated C. albicans and S. oralis in high and low concentrations from both types of plates, whereas 2-propanol did not eliminate all micro-organisms at high concentrations. The UV light eliminated all micro-organisms from the ramp. Ethanol degraded the plates to a larger extent than did 2-propanol. Images from Vista plates showed severe artefacts after wiping with ethanol; those from Digora plates did not. Ethanol eliminated all micro-organisms but degraded phosphor plates, whereas 2-propanol did not eliminate all micro-organisms and still degraded plates from Vista but not from Digora.
Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerous
methods of wipe sampling exist, and each method has its own specification for the type of wipe, we...
Surface sampling for endotoxin assessment using electrostatic wiping cloths.
Thorne, Peter S; Metwali, Nervana; Avol, Ed; McConnell, Rob S
2005-07-01
Much of the cost of exposure assessment for studies of residential cohorts is in scheduling and travel time for field staff. One way to reduce costs is to simplify methods such that subjects can sample their own residence. Analysis of settled dust is being widely used for assessment of exposures to allergens, lead and pesticides and can also be used for endotoxins. While vacuum sampling is the most common surface sampling method, wipe sampling has the advantage that it can be readily performed by the resident when convenient and samples can then be mailed to researchers. Thus, we evaluated the feasibility of wipe sampling for endotoxin environmental assessment using electrostatic wipes with or without the use of disposable examination gloves. Multiple lots of six types of commercial wipes and eight types of gloves were extracted and analyzed for endotoxin content using the kinetic chromogenic Limulus amebocyte lysate assay. Wipes were compared across brands, between lots, within lots, between pairs depending on proximity to cardboard packaging, and in wipe tests with or without gloves. Collected dust samples of known concentration were also tested in spiking assays for endotoxin recovery. The most striking finding was the high variability of endotoxin contamination of both wipes and gloves across brands and between various lots. The content of endotoxin in unused gloves ranged from <1.5 to 5810 endotoxin units (EU). The range for unused wipes was 3.6-87.8 EU. Surfaces of equal loading and area were sampled using three types of cloths that had low initial endotoxin contamination. The cloths were very good at collecting dust and endotoxin could be assayed from aqueous extracts of the wipes. Samples collected using cloths with bare washed hands yielded higher endotoxin loading per mass of collected dust versus samples collected wearing endotoxin-free gloves. This demonstrated additional endotoxin loading from the subject's hand. This study shows that wipe sampling while wearing medical gloves can be an effective method for collecting and assessing endotoxin on surfaces, so long as each lot of wipes and gloves have been tested and determined to be low in endotoxin.
Connor, Thomas H; Smith, Jerome P
2016-09-01
At the present time, the method of choice to determine surface contamination of the workplace with antineoplastic and other hazardous drugs is surface wipe sampling and subsequent sample analysis with a variety of analytical techniques. The purpose of this article is to review current methodology for determining the level of surface contamination with hazardous drugs in healthcare settings and to discuss recent advances in this area. In addition it will provide some guidance for conducting surface wipe sampling and sample analysis for these drugs in healthcare settings. Published studies on the use of wipe sampling to measure hazardous drugs on surfaces in healthcare settings drugs were reviewed. These studies include the use of well-documented chromatographic techniques for sample analysis in addition to newly evolving technology that provides rapid analysis of specific antineoplastic. Methodology for the analysis of surface wipe samples for hazardous drugs are reviewed, including the purposes, technical factors, sampling strategy, materials required, and limitations. The use of lateral flow immunoassay (LFIA) and fluorescence covalent microbead immunosorbent assay (FCMIA) for surface wipe sample evaluation is also discussed. Current recommendations are that all healthc a re settings where antineoplastic and other hazardous drugs are handled include surface wipe sampling as part of a comprehensive hazardous drug-safe handling program. Surface wipe sampling may be used as a method to characterize potential occupational dermal exposure risk and to evaluate the effectiveness of implemented controls and the overall safety program. New technology, although currently limited in scope, may make wipe sampling for hazardous drugs more routine, less costly, and provide a shorter response time than classical analytical techniques now in use.
Galea, Karen S; Mueller, Will; Arfaj, Ayman M; Llamas, Jose L; Buick, Jennifer; Todd, David; McGonagle, Carolyn
2018-05-21
Crude oil may cause adverse dermal effects therefore dermal exposure is an exposure route of concern. Galea et al. (2014b) reported on a study comparing recovery (wipe) and interception (cotton glove) dermal sampling methods. The authors concluded that both methods were suitable for assessing dermal exposure to oil-based drilling fluids and crude oil but that glove samplers may overestimate the amount of fluid transferred to the skin. We describe a study which aimed to further evaluate the wipe sampling method to assess dermal exposure to crude oil, with this assessment including extended sample storage periods and sampling efficiency tests being undertaken at environmental conditions to mimic those typical of outdoor conditions in Saudi Arabia. The wipe sampling method was then used to assess the laboratory technicians' actual exposure to crude oil during typical petroleum laboratory tasks. Overall, acceptable storage efficiencies up to 54 days were reported with results suggesting storage stability over time. Sampling efficiencies were also reported to be satisfactory at both ambient and elevated temperature and relative humidity environmental conditions for surrogate skin spiked with known masses of crude oil and left up to 4 h prior to wiping, though there was an indication of reduced sampling efficiency over time. Nineteen petroleum laboratory technicians provided a total of 35 pre- and 35 post-activity paired hand wipe samples. Ninety-three percent of the pre-exposure paired hand wipes were less than the analytical limit of detection (LOD), whereas 46% of the post-activity paired hand wipes were less than the LOD. The geometric mean paired post-activity wipe sample measurement was 3.09 µg cm-2 (range 1.76-35.4 µg cm-2). It was considered that dermal exposure most frequently occurred through direct contact with the crude oil (emission) or via deposition. The findings of this study suggest that the wipe sampling method is satisfactory in quantifying laboratory technicians' dermal exposure to crude oil. It is therefore considered that this wipe sampling method may be suitable to quantify dermal exposure to crude oil for other petroleum workers.
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN DERMAL WIPES ANALYTICAL RESULTS
The Pesticides in Dermal Wipe Samples data set contains analytical results for measurements of up to 8 pesticides in 40 dermal wipe samples over 40 households. Each sample was collected from the primary respondent within each household. The sampling period occurred on the last ...
NHEXAS PHASE I MARYLAND STUDY--METALS IN DERMAL WIPES ANALYTICAL RESULTS
The Metals in Dermal Wipe Samples data set contains analytical results for measurements of up to 4 metals in 343 dermal wipe samples over 80 households. Each sample was collected from the primary respondent within each household. The sampling period occurred on the first day of...
Allergenic Ingredients in Facial Wet Wipes.
Aschenbeck, Kelly A; Warshaw, Erin M
Allergic contact dermatitis commonly occurs on the face. Facial cleansing wipes may be an underrecognized source of allergens. The aim of this study was to determine the frequency of potentially allergenic ingredients in facial wet wipes. Ingredient lists from name brand and generic facial wipes from 4 large retailers were analyzed. In the 178 facial wipes examined, a total of 485 ingredients were identified (average, 16.7 ingredients per wipe). Excluding botanicals, the top 15 potentially allergenic ingredients were glycerin (64.0%), fragrance (63.5%), phenoxyethanol (53.9%), citric acid (51.1%), disodium EDTA (44.4%), sorbic acid derivatives (39.3%), tocopherol derivatives (38.8%), polyethylene glycol derivatives (32.6%), glyceryl stearate (31.5%), sodium citrate (29.8%), glucosides (27.5%), cetearyl alcohol (25.8%), propylene glycol (25.3%), sodium benzoate (24.2%), and ceteareth-20 (23.6%)/parabens (23.6%). Of note, methylisothiazolinone (2.2%) and methylchloroisothiazolinone (1.1%) were uncommon. The top potential allergens of botanical origin included Aloe barbadensis (41.0%), chamomile extracts (27.0%), tea extracts (21.3%), Cucumis sativus (20.2%), and Hamamelis virginiana (10.7%). Many potential allergens are present in facial wet wipes, including fragrances, preservatives, botanicals, glucosides, and propylene glycol.
Todd, Ewen C D; Michaels, Barry S; Holah, John; Smith, Debra; Greig, Judy D; Bartleson, Charles A
2010-11-01
Alcohol compounds are increasingly used as a substitute for hand washing in health care environments and some public places because these compounds are easy to use and do not require water or hand drying materials. However, the effectiveness of these compounds depends on how much soil (bioburden) is present on the hands. Workers in health care environments and other public places must wash their hands before using antiseptics and/or wearing gloves. However, alcohol-based antiseptics, also called rubs and sanitizers, can be very effective for rapidly destroying some pathogens by the action of the aqueous alcohol solution without the need for water or drying with towels. Alcohol-based compounds seem to be the most effective treatment against gram-negative bacteria on lightly soiled hands, but antimicrobial soaps are as good or better when hands are more heavily contaminated. Instant sanitizers have no residual effect, unlike some antimicrobial soaps that retain antimicrobial activity after the hygienic action has been completed, e.g., after hand washing. Many alcohol-based hand rubs have antimicrobial agents added to them, but each formulation must be evaluated against the target pathogens in the environment of concern before being considered for use. Wipes also are widely used for quick cleanups of hands, other body parts, and surfaces. These wipes often contain alcohol and/or antimicrobial compounds and are used for personal hygiene where water is limited. However, antiseptics and wipes are not panaceas for every situation and are less effective in the presence of more than a light soil load and against most enteric viruses.
Surface wipe sampling is a frequently used technique for measuring persistent pollutants in residential environments. One characteristic of this form of sampling is the need to extract the entire wipe sample to achieve adequate sensitivity and to ensure representativeness. Most s...
NHEXAS PHASE I ARIZONA STUDY--METALS IN DERMAL WIPES ANALYTICAL RESULTS
The Metals in Dermal Wipes data set contains analytical results for measurements of up to 11 metals in 179 dermal wipe samples over 179 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sampling per...
Ďurč, Pavol; Foret, František; Pokojová, Eva; Homola, Lukáš; Skřičková, Jana; Herout, Vladimír; Dastych, Milan; Vinohradská, Hana; Kubáň, Petr
2017-05-01
A new approach for sweat analysis used in cystic fibrosis (CF) diagnosis is proposed. It consists of a noninvasive skin-wipe sampling followed by analysis of target ions using capillary electrophoresis with contactless conductometric detection (C4D). The skin-wipe sampling consists of wiping a defined skin area with precleaned cotton swab moistened with 100 μL deionized water. The skin-wipe sample is then extracted for 3 min into 400 μL deionized water, and the extract is analyzed directly. The developed sampling method is cheap, simple, fast, and painless, and can replace the conventional pilocarpine-induced sweat chloride test commonly applied in CF diagnosis. The aqueous extract of the skin-wipe sample content is analyzed simultaneously by capillary electrophoresis with contactless conductometric detection using a double opposite end injection. A 20 mmol/L L-histidine/2-(N-morpholino)ethanesulfonic acid and 2 mmol/L 18-crown-6 at pH 6 electrolyte can separate all the major ions in less than 7 min. Skin-wipe sample extracts from 30 study participants-ten adult patients with CF (25-50 years old), ten pediatric patients with CF (1-15 years old), and ten healthy control individuals (1-18 years old)-were obtained and analyzed. From the analyzed ions in all samples, a significant difference between chloride and potassium concentrations was found in the CF patients and healthy controls. We propose the use of the Cl - /K + ratio rather than the absolute Cl - concentration and a cutoff value of 4 in skin-wipe sample extracts as an alternative to the conventional sweat chloride analysis. The proposed Cl - /K + ion ratio proved to be a more reliable indicator, is independent of the patient's age, and allows better differentiation between non-CF individuals and CF patients having intermediate values on the Cl - sweat test. Figure New approach for cystic fibrosis diagnosis based on skin-wipe sampling of forearm and analysis of ionic content (Cl - /K + ratio) in skin-wipe extracts by capillary electrophoresis with contactless conductometric detection.
The method for extracting and preparing a dermal or surface wipe sample for analysis of acidic persistent organic pollutants is summarized in this standard operating procedure. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mas...
The purpose of this SOP is to describe the procedures for extracting and preparing a sill surface wipe sample for gas chromatography/mass spectrometry (GC/MS) analysis of pesticides. This procedure is also used for the pre-shipment analysis of sill wipe samples for materials sui...
Estimating dermal transfer from PCB-contaminated porous surfaces.
Slayton, T M; Valberg, P A; Wait, A D
1998-06-01
Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.
Van Nimmen, Nadine F J; Veulemans, Hendrik A F
2004-05-07
A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated air sampling was investigated. For fentanyl and sufentanil a quantitative recovery was observed at all spike levels, while for alfentanil recoveries ranged from 60.3 to 85.4%. When spiked air samples were stored at ambient temperature and at -15 degrees C quantitative recovery was found for fentanyl and sufentanil after 7 and 14 days. For alfentanil a slight loss seemed to occur upon storage during 7 days, being more explicit after 14 days. Ambient storage of spiked wipes seemed to lead to significant losses of all opioids studied, yielding recoveries of 37.7-88.3%. Upon storage of similar wipes at -15 degrees C a significantly higher recovery was found ranging from 77.3 to 88.3%. The developed analytical and sampling procedures have been recently applied in an explorative field study of which the results of surface contamination wipe sampling are presented in this paper. To our knowledge, this is the first study addressing the development and validation of analytical procedures for the assessment of external occupational exposure to potent opioid narcotics.
Oughton, Matthew T; Loo, Vivian G; Dendukuri, Nandini; Fenn, Susan; Libman, Michael D
2009-10-01
To evaluate common hand hygiene methods for efficacy in removing Clostridium difficile. Randomized crossover comparison among 10 volunteers with hands experimentally contaminated by nontoxigenic C. difficile. Interventions included warm water with plain soap, cold water with plain soap, warm water with antibacterial soap, antiseptic hand wipes, alcohol-based handrub, and a control involving no intervention. All interventions were evaluated for mean reduction in colony-forming units (CFUs) under 2 contamination protocols: "whole hand" and "palmar surface." Results were analyzed according to a Bayesian approach, by using hierarchical models adjusted for multiple observations. Under the whole-hand protocol, the greatest adjusted mean reductions were achieved by warm water with plain soap (2.14 log(10) CFU/mL [95% credible interval (CrI), 1.74-2.54 log(10) CFU/mL]), cold water with plain soap (1.88 log(10) CFU/mL [95% CrI, 1.48-2.28 log(10) CFU/mL), and warm water with antibacterial soap (1.51 log(10) CFU/mL [95% CrI, 1.12-1.91 log(10) CFU/mL]), followed by antiseptic hand wipes (0.57 log(10) CFU/mL [95% CrI, 0.17-0.96 log(10) CFU/mL]). Alcohol-based handrub (0.06 log(10) CFU/mL [95% CrI, -0.34 to 0.45 log(10) CFU/mL]) was equivalent to no intervention. Under the palmar surface protocol, warm water with plain soap, cold water with plain soap, and warm water with antibacterial soap again yielded the greatest mean reductions, followed by antiseptic hand wipes (26.6, 26.6, 26.6, and 21.9 CFUs per plate, respectively), when compared with alcohol-based handrub. Hypothenar (odds ratio, 10.98 [95% CrI, 1.96-37.65]) and thenar (odds ratio, 6.99 [95% CrI, 1.25-23.41]) surfaces were more likely than fingertips to remain heavily contaminated after handwashing. Handwashing with soap and water showed the greatest efficacy in removing C. difficile and should be performed preferentially over the use of alcohol-based handrubs when contact with C. difficile is suspected or likely.
NHEXAS PHASE I ARIZONA STUDY--PESTICIDES IN DERMAL WIPES ANALYTICAL RESULTS
The Pesticides in Dermal Wipes data set contains analytical results for measurements of up to 3 pesticides in 177 dermal wipe samples over 177 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The Derma...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDES IN DERMAL ANALYTICAL RESULTS
The Pesticides in Dermal Wipes data set contains analytical results for measurements of up to 8 pesticides in 86 dermal wipe samples over 86 households. Each sample was collected from the primary respondent within each household. The Dermal/Pesticide hand wipe was collected 7 d...
Associations between PBDEs in Office Air, Dust, and Surface Wipes
Watkins, Deborah J.; McClean, Michael D.; Fraser, Alicia J.; Weinberg, Janice; Stapleton, Heather M.; Webster, Thomas F.
2013-01-01
Increased use of flame-retardants in office furniture may increase exposure to PBDEs in the office environment. However, partitioning of PBDEs within the office environment is not well understood. Our objectives were to examine relationships between concurrent measures of PBDEs in office air, floor dust, and surface wipes. We collected air, dust, and surface wipe samples from 31 offices in Boston, MA. Correlation and linear regression were used to evaluate associations between variables. Geometric mean (GM) concentrations of individual BDE congeners in air and congener specific octanol-air partition coefficients (Koa) were used to predict GM concentrations in dust and surface wipes and compared to the measured concentrations. GM concentrations of PentaBDEs in office air, dust, and surface wipes were 472 pg/m3, 2411 ng/g, and 77 pg/cm2, respectively. BDE209 was detected in 100% of dust samples (GM=4202 ng/g), 93% of surface wipes (GM=125 pg/cm2), and 39% of air samples. PentaBDEs in dust and air were moderately correlated with each other (r=0.60, p=0.0003), as well as with PentaBDEs in surface wipes (r=0.51, p=0.003 for both dust and air). BDE209 in dust was correlated with BDE209 in surface wipes (r=0.69, p=0.007). Building (three categories) and PentaBDEs in dust were independent predictors of PentaBDEs in both air and surface wipes, together explaining 50% (p=0.0009) and 48% (p=0.001) of the variation respectively. Predicted and measured concentrations of individual BDE congeners were highly correlated in dust (r=0.98, p<0.0001) and surface wipes (r=0.94, p=002). BDE209 provided an interesting test of this equilibrium partitioning model as it is a low volatility compound. Associations between PentaBDEs in multiple sampling media suggest that collecting dust or surface wipes may be a convenient method of characterizing exposure in the indoor environment. The volatility of individual congeners, as well as physical characteristics of the indoor environment, influence relationships between PBDEs in air, dust, and surface wipes. PMID:23797055
Larson, Elaine L; Cohen, Bevin; Baxter, Kathleen A
2012-11-01
Minimal research has been published evaluating the effectiveness of hand hygiene delivery systems (ie, rubs, foams, or wipes) at removing viruses from hands. The purposes of this study were to determine the effect of several alcohol-based hand sanitizers in removing influenza A (H1N1) virus, and to compare the effectiveness of foam, gel, and hand wipe products. Hands of 30 volunteers were inoculated with H1N1 and randomized to treatment with foam, gel, or hand wipe applied to half of each volunteer's finger pads. The log(10) count of each subject's treated and untreated finger pads were averaged. Log(10) reductions were calculated from these differences and averaged within treatment group. Between-treatment analysis compared changes from the untreated finger pads using analysis of covariance with treatment as a factor and the average log(10) untreated finger pads as the covariate. Log(10) counts on control finger pads were 2.7-5.3 log(10) of the 50% infectious dose for tissue culture (TCID(50)/0.1 mL) (mean, 3.8 ± 0.5 log(10) TCID(50)/0.1 mL), and treated finger pad counts for all test products were 0.5-1.9 log(10) TCID(50)/0.1 mL (mean, 0.53 ± 0.17 log(10) TCID(50)/0.1 mL). Treatments with all products resulted in a significant reduction in viral titers (>3 logs) at their respective exposure times that were statistically comparable. All 3 delivery systems (foam, gel, and wipe) produced significantly reduced viral counts on hands. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
This SOP summarizes the method for extracting and preparing a hard floor surface wipe or food preparation surface wipe sample for analysis of neutral persistent organic. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spect...
The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: dermal wipe;...
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...
Colling Wipe Samples for VX Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koester, C; Hoppes, W G
2010-02-11
This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.
The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keywords: dermal wipe; p...
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
Brown, Gary S.; Betty, Rita G.; Brockmann, John E.; Lucero, Daniel A.; Souza, Caroline A.; Walsh, Kathryn S.; Boucher, Raymond M.; Tezak, Mathew; Wilson, Mollye C.; Rudolph, Todd
2007-01-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis. PMID:17122390
Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Mathew; Wilson, Mollye C; Rudolph, Todd
2007-02-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.
... administer the injection, follow these steps: Clean the injection site with an alcohol wipe using a circular motion, ... to pinch a fold of skin at the injection site. Do not lay the syringe down or allow ...
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
Lavender, Tina; Furber, Christine; Campbell, Malcolm; Victor, Suresh; Roberts, Ian; Bedwell, Carol; Cork, Michael J
2012-06-01
Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants (<1 month) has an equivalent effect on skin hydration when compared with using cotton wool and water (usual care). A prospective, assessor-blinded, randomised controlled equivalence trial was conducted during 2010. Healthy, term babies (n=280), recruited within 48 hours of birth, were randomly assigned to have their napkin area cleansed with an alcohol-free baby wipe (140 babies) or cotton wool and water (140 babies). Primary outcome was change in hydration from within 48 hours of birth to 4 weeks post-birth. Secondary outcomes comprised changes in trans-epidermal water loss, skin surface pH and erythema, presence of microbial skin contaminants/irritants at 4 weeks and napkin dermatitis reported by midwife at 4 weeks and mother during the 4 weeks. Complete hydration data were obtained for 254 (90.7 %) babies. Wipes were shown to be equivalent to water and cotton wool in terms of skin hydration (intention-to-treat analysis: wipes 65.4 (SD 12.4) vs. water 63.5 (14.2), p=0.47, 95% CI -2.5 to 4.2; per protocol analysis: wipes 64.6 (12.4) vs. water 63.6 (14.3), p=0.53, 95% CI -2.4 to 4.2). No significant differences were found in the secondary outcomes, except for maternal-reported napkin dermatitis, which was higher in the water group (p=0.025 for complete responses). Baby wipes had an equivalent effect on skin hydration when compared with cotton wool and water. We found no evidence of any adverse effects of using these wipes. These findings offer reassurance to parents who choose to use baby wipes and to health professionals who support their use. Current Controlled Trials ISRCTN86207019.
Lutz, J K; Crawford, J; Hoet, A E; Wilkins, J R; Lee, J
2013-07-01
To evaluate the performance of four sampling methods [contact plates, electrostatic wipes (wipe), swabs and a novel roller sampler] for recovery of Staphylococcus aureus from a stainless steel surface. Stainless steel test plates were inoculated with Staph. aureus, dried for 24 h and sampled using each of the four methods. Samples were either incubated directly (roller, contact plate) or processed using elution and membrane filtration (swab, wipe). Performance was assessed by calculating the apparent sampling efficiency (ASE), analytical sensitivity (Sn) and percentage of replications with positive growth. The wipe demonstrated the best performance across all inoculating concentrations (ASE(48 h) = 18%; Sn(48 h) = 7 CFU per 100 cm(2)). The swab performed well when corrected for area actually sampled (ASE(48 h) = 24%; Sn(48 h) = 76 CFU per 100 cm(2)). Of the contact-based methods, the newly developed roller sampler outperformed the contact plate (roller: ASE(48 h) = 10%; Sn(48 h) = 17 CFU per 100 cm(2); contact plate: ASE(48 h) = 0·04%; Sn(48 h) = 1412 CFU per 100 cm(2)); both contact samplers performed better at higher inoculating concentrations (6E3 CFU per 100 cm(2) for the roller and 6E6 CFU per 100 cm(2) for the contact plate). Overall, the electrostatic wipe produced the highest number of replications resulting in positive growth (74%(24 h), 91%(48 h)). This study demonstrates that selection of the sampling method must be carefully considered, given that different methods have varying performance. This is the first study assessing static wipes for sampling and one that uses a more real-world-relevant 24-h drying time. The results help with infection control, and environmental health professionals choose better sampling methodologies. Journal of Applied Microbiology © 2013 The Society for Applied Microbiology.
Hines, Cynthia J; Christianson, Annette L; Jackson, Matthew V; Ye, Xiaoyun; Pretty, Jack R; Arnold, James E; Calafat, Antonia M
2018-06-13
Exposure to bisphenol A (BPA) can be assessed using external and internal exposure measures. We examined the relationship between two measures of external BPA exposure (air and hand-wipe samples) and one of internal exposure (total BPA in urine) for a group of US manufacturing workers. During 2013-2014, we recruited 78 workers from six US companies that made BPA or made products with BPA. We quantified BPA in seven urine samples, two full-shift air samples and in pre- and end-shift hand-wipe samples collected from workers over 2 consecutive days. We examined correlations between creatinine-corrected urinary concentrations of total BPA (total BPACR) and BPA levels in air and hand wipes using Pearson's correlation coefficient. We also applied mixed-effects regression models to examine the relationship between total BPACR with BPA in air (urine~air model) and with BPA in end-shift hand wipes (urine~hand model), separately and together (urine~air+hand model), after adjusting for covariates. End-shift total BPACR strongly correlated with BPA in air (rp = 0.79, P < 0.0001) and nearly as strongly with BPA in end-shift hand wipes (rp = 0.75, P < 0.0001). In mixed-effect models, BPA air concentration and end-shift hand-wipe BPA level were significantly and positively associated with end-shift total BPACR (P < 0.0001 each). We found a significant effect of the Day 1 BPA air concentration on Day 2 total BPACR (P = 0.0104). When BPA air concentration and end-shift hand-wipe BPA level were in the same model, the air concentration (P < 0.0001) was more significant than the hand-wipe level (P = 0.0106). BPA levels in air and end-shift hand wipes strongly correlated with total BPACR, suggesting that both inhalation and dermal contract were likely exposure routes; however, inhalation, on average, appeared to be a more dominant exposure route than dermal contact for these manufacturing workers.
Monitoring Indoor Exposure to Organophosphate Flame Retardants: Hand Wipes and House Dust
Hoffman, Kate; Garantziotis, Stavros; Birnbaum, Linda S.
2014-01-01
Background: Organophosphate flame retardants (PFRs) are becoming popular replacements for the phased-out polybrominated diphenyl ether (PBDE) mixtures, and they are now commonly detected in indoor environments. However, little is known about human exposure to PFRs because they cannot be easily measured in blood or serum. Objectives: To investigate relationships between the home environment and internal exposure, we assessed associations between two PFRs, tris(1,3-dichloropropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP), in paired hand wipe and dust samples and concentrations of their metabolites in urine samples (n = 53). We also assessed short-term variation in urinary metabolite concentrations (n = 11 participants; n = 49 samples). Methods: Adult volunteers in North Carolina, USA, completed questionnaires and provided urine, hand wipe, and household dust samples. PFRs and PBDEs were measured in hand wipes and dust, and bis(1,3-dichloropropyl) phosphate (BDCIPP) and diphenyl phosphate (DPHP), metabolites of TDCIPP and TPHP, were measured in urine. Results: TDCIPP and TPHP were detected frequently in hand wipes and dust (> 86.8%), with geometric mean concentrations exceeding those of PBDEs. Unlike PBDEs, dust TDCIPP and TPHP levels were not associated with hand wipes. However, hand wipe levels were associated with urinary metabolites. Participants with the highest hand wipe TPHP mass, for instance, had DPHP levels 2.42 times those of participants with the lowest levels (95% CI: 1.23, 4.77). Women had higher levels of DPHP, but not BDCIPP. BDCIPP and DPHP concentrations were moderately to strongly reliable over 5 consecutive days (intraclass correlation coefficients of 0.81 and 0.51, respectively). Conclusions: PFR exposures are widespread, and hand-to-mouth contact or dermal absorption may be important pathways of exposure. Citation: Hoffman K, Garantziotis S, Birnbaum LS, Stapleton HM. 2015. Monitoring indoor exposure to organophosphate flame retardants: hand wipes and house dust. Environ Health Perspect 123:160–165; http://dx.doi.org/10.1289/ehp.1408669 PMID:25343780
Lab Analysis of Dust Wipe Samples
Dust wipe samples collected on residential properties near the fenceline of KCBX North and South Terminals in Chicago, which store and handle pet coke, were analyzed for polycyclic aromatic hydrocarbons (PAHs) and trace metals and minerals.
40 CFR 761.243 - Standard wipe sample method and size.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., AND USE PROHIBITIONS Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe.../Rinse Cleanup as Recommended by the Environmental Protection Agency PCB Spill Cleanup Policy,” dated...
Efficiency of wipe sampling on hard surfaces for pesticides and PCB residues in dust.
Cettier, Joane; Bayle, Marie-Laure; Béranger, Rémi; Billoir, Elise; Nuckols, John R; Combourieu, Bruno; Fervers, Béatrice
2015-02-01
Pesticides and polychlorinated biphenyls (PCBs) are commonly found in house dust and have been described as a valuable matrix to assess indoor pesticide and PCB contamination. The aim of this study was to assess the efficiency and precision of cellulose wipe for collecting 48 pesticides, eight PCBs, and one synergist at environmental concentrations. First, the efficiency and repeatability of wipe collection were determined for pesticide and PCB residues that were directly spiked onto three types of household floors (tile, laminate, and hardwood). Second, synthetic dust was used to assess the capacity of the wipe to collect dust. Third, we assessed the efficiency and repeatability of wipe collection of pesticides and PCB residues that was spiked onto synthetic dust and then applied to tile. In the first experiment, the overall collection efficiency was highest on tile (38%) and laminate (40%) compared to hardwood (34%), p<0.001. The second experiment confirmed that cellulose wipes can efficiently collect dust (82% collection efficiency). The third experiment showed that the overall collection efficiency was higher in the presence of dust (72% vs. 38% without dust, p<0.001). Furthermore, the mean repeatability also improved when compounds were spiked onto dust (<30% for the majority of compounds). To our knowledge, this is the first study to assess the efficiency of wipes as a sampling method using a large number of compounds at environmental concentrations and synthetic dust. Cellulose wipes appear to be efficient to sample the pesticides and PCBs that adsorb onto dust on smooth and hard surfaces. Copyright © 2014 Elsevier B.V. All rights reserved.
Assessment of skin exposure to nickel, chromium and cobalt by acid wipe sampling and ICP-MS.
Lidén, Carola; Skare, Lizbet; Lind, Birger; Nise, Gun; Vahter, Marie
2006-05-01
There is a great need to accurately assess skin exposure to contact allergens. We have developed a technique for assessment of skin exposure to nickel, chromium and cobalt using acid wipe sampling by cellulose wipes with 1% nitric acid. Chemical analysis was performed by inductively coupled plasma mass spectrometry (ICP-MS). The recovery of nickel, chromium and cobalt from arms and palms was 93%. The analytical result is expressed in terms of mass per unit area (microg/cm(2)). The developed acid wipe sampling technique is suitable for determination of nickel, chromium and cobalt deposited on the skin. The technique may be used in workplace studies, in studies of individuals in the general population, in dermatitis patients, in identification of risk groups, as well as in developing preventive strategies and in follow-up after intervention.
Willison, Stuart A
2015-01-20
The persistence of chemical warfare nerve agent degradation analytes on surfaces is important, from indicating the presence of nerve agent on a surface to guiding environmental restoration of a site after a release. Persistence was investigated for several chemical warfare nerve agent degradation analytes on indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces included porous/permeable (vinyl tile, painted drywall, and wood) and largely nonporous/impermeable (laminate, galvanized steel, and glass) surfaces. Wipe extracts were analyzed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). UPLC provides a separation of targeted degradation analytes in addition to being nearly four times faster than high-performance liquid chromatography, allowing for greater throughput after a large-scale contamination incident and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), GB degradate; 61-91% for ethyl methylphosphonate (EMPA), VX degradate; and 60-98% for pinacolyl methylphosphonate (PMPA), GD degradate. Recovery efficiencies for methyl phosphonate (MPA), nerve agent degradate, and ethylhydrogen dimethylphosphonate (EHDMAP), GA degradate, were lower, perhaps due to matrix effects. Diisopropyl methylphosphonate, GB impurity, was not recovered from surfaces. The resulting detection limits for wipe extracts were 0.065 ng/cm(2) for IMPA, 0.079 ng/cm(2) for MPA, 0.040 ng/cm(2) for EMPA, 0.078 ng/cm(2) for EHDMAP, and 0.013 ng/cm(2) for PMPA. The data indicate that laboratories may hold wipe samples for up to 30 days prior to analysis. Target analytes were observed to persist on surfaces for at least 6 weeks.
Comparison of sampling methods used for MRSA-classification of herds with breeding pigs.
Broens, E M; Graat, E A M; Engel, B; van Oosterom, R A A; van de Giessen, A W; van der Wolf, P J
2011-01-27
Since the first report on methicillin resistant Staphylococcus aureus (MRSA) CC398 in pigs, several countries have determined the prevalence of MRSA-positive pig herds using different sampling and laboratory techniques. The objective of the study was to compare three sampling methods for MRSA-classification of herds. Therefore, nasal swabs of pigs and environmental wipes were collected from 147 herds with breeding pigs. Per herd, laboratory examination was done on 10 pools of 6 nasal swabs (NASAL), 5 single environmental wipes (ENVSINGLE) and one pool of 5 environmental wipes (ENVPOOL). Large differences in apparent prevalence of MRSA-positive herds between methods were found: 19.1% for ENVPOOL, 53.1% for ENVSINGLE, and 70.8% for NASAL. Pairwise comparisons of methods resulted in relative sensitivities of 26.9% (ENVPOOL vs. NASAL), 34.6% (ENVPOOL vs. ENVSINGLE), and 72.1% (ENVSINGLE vs. NASAL) with relative specificities of respectively 100%, 98.6% and 93.0%. Cohen's kappa was respectively 0.18, 0.32 and 0.55, thus varying between very poor and moderate agreement. Examination of environmental wipes is an easy and non-invasive method to classify herds for MRSA. The number of environmental wipes needed depends on e.g. required detection limits and within-herd prevalence. In low prevalent herds (e.g. herds with <3 positive pools of nasal swabs), 25 single environmental wipes are required to be 90% sure that MRSA is detected at a detection limit similar to analyzing 10 pools of nasal swabs. Individual analysis of environmental wipes is highly recommended, as pooling 5 environmental samples resulted in a substantial reduction of the apparent prevalence. Copyright © 2010 Elsevier B.V. All rights reserved.
Microbiological cleanliness of the Mars Exploration Rover spacecraft
NASA Technical Reports Server (NTRS)
Newlin, L.; Barengoltz, J.; Chung, S.; Kirschner, L.; Koukol, R.; Morales, F.
2002-01-01
Planetary protection for Mars missions is described, and the approach being taken by the Mars Exploration Rover Project is discussed. Specific topics include alcohol wiping, dry heat microbial reduction, microbiological assays, and the Kennedy Space center's PHSF clean room.
Giving an IM (intramuscular) injection
... Wash your hands well with soap and water. Dry them. Carefully find the spot where you will give the injection. Clean the skin at that spot with an alcohol wipe. Let it dry. Take the cap off the needle. Hold the ...
Bennett, D. H.; Moran, R. E.; Wu, X. (May); Tulve, N. S.; Clifton, M. S.; Colón, M.; Weathers, W.; Sjödin, A.; Jones, R.; Hertz-Picciotto, I.
2016-01-01
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57–0.90), with the exception of BDE209 which was not well correlated longitudinally. PMID:24832910
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN DERMAL ANALYTICAL RESULTS
The Metals in Dermal Wipes data set contains analytical results for measurements of up to 11 metals in 86 dermal wipe samples over 86 households. Each sample was collected from the primary respondent within each household. The sampling period occurred on the first day of the fi...
The method for extracting and preparing a dermal (hand) wipe sample for analysis of neutral persistent organic pollutants is summarized in this SOP. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spectrometry.
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
Gulson, Brian; Korsch, Michael; Bradshaw, Anthony
2016-01-01
Concerns have been expressed that dust from the minerals processing facilities at Karumba Queensland Australia have resulted in elevated lead (Pb) concentrations in rain water tanks. The ores derived from the Century mine some 304 km from the port. High precision Pb isotopic measurements on environmental samples have been undertaken to evaluate the source of Pb in rainwaters and acid digests from roof wipes and gutter wipes. There does not appear to be any relationship between sample location and the processing facility but samples from the area subject to the prevailing winds show the highest contribution of Century Pb. All gutter wipes (82 to 1270 µg Pb/wipe) have contributions of Century ore ranging from 87% to 96%. The contribution of Century ore to five roof wipes (22 to 88 µg Pb/wipe) ranges from 89% to 97% and in the other two samples there is a mix of Century and Broken Hill Pb. Three of the seven rainwater have contributions of Century ore Pb ranging from 33% to 75%. Two of the other four rainwater samples have the highest water Pb concentrations of 88 and 100 µg/L and their isotopic data show Broken Hill Pb contributions ranging from 77% to 80%. The source of the Broken Hill Pb is probably from the galvanized roofing material and/or brass fittings in the rainwater tanks. The discrimination between various sources is only detectable using high precision 204Pb-based isotopic ratios and not the now common inductively coupled plasma mass spectrometry (ICP-MS ) data presentations of the higher abundance isotopes 208Pb, 207Pb and 206Pb. Isotopic results for the waters demonstrate that apportioning blame where there is an obvious point source may not always be the correct conclusion. Nevertheless the isotopic data for the gutter wipes indicates that there was widespread contamination from the processing facilities throughout the town. PMID:26907319
Gulson, Brian; Korsch, Michael; Bradshaw, Anthony
2016-02-22
Concerns have been expressed that dust from the minerals processing facilities at Karumba Queensland Australia have resulted in elevated lead (Pb) concentrations in rain water tanks. The ores derived from the Century mine some 304 km from the port. High precision Pb isotopic measurements on environmental samples have been undertaken to evaluate the source of Pb in rainwaters and acid digests from roof wipes and gutter wipes. There does not appear to be any relationship between sample location and the processing facility but samples from the area subject to the prevailing winds show the highest contribution of Century Pb. All gutter wipes (82 to 1270 µg Pb/wipe) have contributions of Century ore ranging from 87% to 96%. The contribution of Century ore to five roof wipes (22 to 88 µg Pb/wipe) ranges from 89% to 97% and in the other two samples there is a mix of Century and Broken Hill Pb. Three of the seven rainwater have contributions of Century ore Pb ranging from 33% to 75%. Two of the other four rainwater samples have the highest water Pb concentrations of 88 and 100 µg/L and their isotopic data show Broken Hill Pb contributions ranging from 77% to 80%. The source of the Broken Hill Pb is probably from the galvanized roofing material and/or brass fittings in the rainwater tanks. The discrimination between various sources is only detectable using high precision (204)Pb-based isotopic ratios and not the now common inductively coupled plasma mass spectrometry (ICP-MS ) data presentations of the higher abundance isotopes (208)Pb, (207)Pb and (206)Pb. Isotopic results for the waters demonstrate that apportioning blame where there is an obvious point source may not always be the correct conclusion. Nevertheless the isotopic data for the gutter wipes indicates that there was widespread contamination from the processing facilities throughout the town.
Estill, Cheryl Fairfield; Baron, Paul A.; Beard, Jeremy K.; Hein, Misty J.; Larsen, Lloyd D.; Rose, Laura; Schaefer, Frank W.; Noble-Wang, Judith; Hodges, Lisa; Lindquist, H. D. Alan; Deye, Gregory J.; Arduino, Matthew J.
2009-01-01
After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm2). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm2) or wipe or vacuum (929 cm2) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm2) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm2 for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm2 for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans. PMID:19429546
Estill, Cheryl Fairfield; Baron, Paul A; Beard, Jeremy K; Hein, Misty J; Larsen, Lloyd D; Rose, Laura; Schaefer, Frank W; Noble-Wang, Judith; Hodges, Lisa; Lindquist, H D Alan; Deye, Gregory J; Arduino, Matthew J
2009-07-01
After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm(2)). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm(2)) or wipe or vacuum (929 cm(2)) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm(2)) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm(2) for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm(2) for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans.
Feasibility: An important but neglected issue in patient hand hygiene.
Knighton, Shanina C; McDowell, Cherese; Rai, Herleen; Higgins, Patricia; Burant, Christopher; Donskey, Curtis J
2017-06-01
Patient hand hygiene may be a useful strategy to prevent acquisition of pathogens and to reduce the risk for transmission by colonized patients. Several studies demonstrate that patients and long-term-care facility (LTCF) residents may have difficulty using hand hygiene products that are provided; however, none of them measure feasibility for patients to use different hand hygiene products. A convenience sample of 42 hospitalized patients and 46 LTCF residents was assessed for their ability to use 3 hand sanitizer products (8-oz pushdown pump bottle, 2-oz pocket-sized bottle with a reclosable lid, and alcohol-impregnated hand wipes). The time (seconds) required for accessing each product was compared among acute-care patients and LTCF residents. Participants provided feedback on which product they preferred and found easiest to use. Of 88 participants, 86 (97.7%) preferred the pushdown pump, 2 (2.3%) preferred the bottle with the reclosable lid, and none preferred the hand wipes. For both hospitalized patients and LTCF residents, the average time required to access the pushdown pump was significantly less than the time required to access the other products (pushdown pump, 0.45 seconds; bottle with reclosable lid, 3.86 seconds; and wipes, 5.66 seconds; P < .001). Feasibility and ease of use should be considered in the selection of hand hygiene products for patients and LTCF residents. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Evaluation of Chemical Warfare Agent Wipe Sampling ...
Report This investigation tested specific (CWAs), including sarin (GB), soman (GD), cyclosarin (GF), sulfur mustard (HD), and O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) on the non-ideal (e.g., porous and permeable) surfaces of drywall, vinyl tile, wood, laminate, and coated glass. Pesticides (diazinon and malathion) were used so that a comparison is possible with existing literature data (1). Experiments included testing with coupons having surface areas of 10 cm2 and 100 cm2. The 10-cm2 coupons were of a size that could easily be extracted in a 2 oz jar (to provide comparative data for CWA recoveries generated by direct extraction) and the 100-cm2 coupons better represented the area of a surface that might typically be sampled by wipe extraction. In addition, CWA, at a normalized surface concentration of 0.1 µg per cm2 surface area, were spiked on coupons of the tested surfaces. Wipes were wetted with either dichloromethane (DCM) or isopropanol (IPA) before sampling for CWA. Experimental parameters include multiple wipe types, porous/permeable surfaces, coupon surface area, solvent used to wet the wipe (i.e., wetting solvent), and the utility of VX-d14 as an extracted internal standard.
Bennett, D H; Moran, R E; Wu, X May; Tulve, N S; Clifton, M S; Colón, M; Weathers, W; Sjödin, A; Jones, R; Hertz-Picciotto, I
2015-04-01
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57-0.90), with the exception of BDE209 which was not well correlated longitudinally. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
On wiping the interior walls of 37-mm closed-face cassettes: an OSHA perspective.
Hendricks, Warren; Stones, Fern; Lillquist, Dean
2009-12-01
As early as 1976, Occupational Safety and Health Administration (OSHA) methods for analyzing metal samples collected using 37-mm polystyrene closed-face cassettes specified that any loose dust be transferred from the cassette to the digestion vessel, that the cassette be rinsed, and that, if necessary, the cassette be wiped out to help ensure that all particles that enter the cassette are included along with the filter as part of the sample for analysis. OSHA analytical methods for metal analysis were recently revised to explicitly require cassette wiping for all metal samples. This change was based on policy that any material entering the collection device constitutes part of the sample and on OSHA Salt Lake Technical Center research showing that invisible residue on the cassette walls can significantly contribute to the total sample results reported. OSHA procedures are consistent with guidance given in the NIOSH Manual of Analytical Methods. This guidance concludes that internal deposits in sampling cassettes should be included in the analysis and that one way to accomplish this would be to wipe or wash the internal surfaces of the cassette and include the material along with the filter for analysis.
Kiffmeyer, Thekla K; Tuerk, Jochen; Hahn, Moritz; Stuetzer, Hartmut; Hadtstein, Claudia; Heinemann, André; Eickmann, Udo
2013-05-01
A large-scale study was carried out in order to determine the contamination level of antineoplastic drugs in pharmacies and to investigate the suitability and effects of wipe sample monitoring at regular intervals. A specific study design was developed. The 130 participating pharmacies were divided into a study and a control group, carrying out five and two wipe sampling cycles, respectively. The work practice was analyzed using questionnaires to identify factors that influence the contamination level. From 1269 wipe samples, 774 (61%) were contaminated with at least one of the analyzed cytotoxic drugs: cyclophosphamide, docetaxel, etoposide, 5-fluorouracil, gemcitabine, ifosfamide, methotrexate, and paclitaxel. A significant decrease of the contamination with cyclophosphamide and 5-fluorouracil was observed in the study group. The Monitoring-Effect Study of Wipe Sampling in Pharmacies method has proven to be a reliable and affordable tool for contamination control. Based on the 90th percentile of the contamination values, a substance-independent performance-based guidance value of 0.1ng cm(-2) has been derived.
Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey
2018-04-01
Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.
NASA Astrophysics Data System (ADS)
Edwards, Nicholas W. M.; Best, Emma L.; Connell, Simon D.; Goswami, Parikshit; Carr, Chris M.; Wilcox, Mark H.; Russell, Stephen J.
2017-12-01
Healthcare associated infections (HCAIs) are responsible for substantial patient morbidity, mortality and economic cost. Infection control strategies for reducing rates of transmission include the use of nonwoven wipes to remove pathogenic bacteria from frequently touched surfaces. Wiping is a dynamic process that involves physicochemical mechanisms to detach and transfer bacteria to fibre surfaces within the wipe. The purpose of this study was to determine the extent to which systematic changes in fibre surface energy and nano-roughness influence removal of bacteria from an abiotic polymer surface in dry wiping conditions, without liquid detergents or disinfectants. Nonwoven wipe substrates composed of two commonly used fibre types, lyocell (cellulosic) and polypropylene, with different surface energies and nano-roughnesses, were manufactured using pilot-scale nonwoven facilities to produce samples of comparable structure and dimensional properties. The surface energy and nano-roughness of some lyocell substrates were further adjusted by either oxygen (O2) or hexafluoroethane (C2F6) gas plasma treatment. Static adpression wiping of an inoculated surface under dry conditions produced removal efficiencies of between 9.4% and 15.7%, with no significant difference (p < 0.05) in the relative removal efficiencies of Escherichia coli, Staphylococcus aureus or Enterococcus faecalis. However, dynamic wiping markedly increased peak wiping efficiencies to over 50%, with a minimum increase in removal efficiency of 12.5% and a maximum increase in removal efficiency of 37.9% (all significant at p < 0.05) compared with static wiping, depending on fibre type and bacterium. In dry, dynamic wiping conditions, nonwoven wipe substrates with a surface energy closest to that of the contaminated surface produced the highest E. coli removal efficiency, while the associated increase in fibre nano-roughness abrogated this trend with S. aureus and E. faecalis.
Siani, Harsha; Wesgate, Rebecca; Maillard, Jean-Yves
2018-05-11
Antimicrobial wipes are increasingly used in health care settings. This study evaluates, in a clinical setting, the efficacy of sporicidal wipes versus a cloth soaked in a 1,000 ppm chlorine solution. A double-crossover study was performed on 2 different surgical and cardiovascular wards in a 1,000-bed teaching hospital over 29 weeks. The intervention period that consisted of surface decontamination with the preimpregnated wipe or cloth soaked in chlorine followed a 5-week baseline assessment of microbial bioburden on surfaces. Environmental samples from 11 surfaces were analyzed weekly for their microbial content. A total of 1,566 environmental samples and 1,591 ATP swabs were analyzed during the trial. Overall, there were significant differences in the recovery of total aerobic bacteria (P < .001), total anaerobic bacteria (P < .001), and ATP measurement (P < .001) between wards and between the different parts of the crossover study. Generally, the use of wipes produced the largest reduction in the total aerobic and anaerobic counts when compared with the baseline data or the use of 1,000 ppm chlorine. Collectively, the introduction of training plus daily wipe disinfection significantly reduced multidrug-resistant organisms recovered from surfaces. Reversion to using 1,000 ppm chlorine resulted in the number of sites positive for multidrug-resistant organisms rising again. This double-crossover study is the first controlled field trial comparison of using preimpregnated wipes versus cotton cloth dipped into a bucket of hypochlorite to decrease surface microbial bioburden. The results demonstrate the superiority of the preimpregnated wipes in significantly decreasing microbial bioburden from high-touch surfaces. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Processes For Cleaning a Cathode Tube and Assemblies In A Hollow Cathode Assembly
NASA Technical Reports Server (NTRS)
Patterson, Michael J. (Inventor); Verhey, Timothy R. R. (Inventor); Soulas, George C. (Inventor)
2001-01-01
The present invention is a process for cleaning a cathode tube and other subassemblies in a hollow cathode assembly. In the disclosed process, hand covering elastomer gloves are used for handling all cathode assembly parts. The cathode tube and other subassemblies are cleaned with a lint-free cloth damped with acetone, then wiped with alcohol, immersed in ethyl alcohol or acetone, and ultrasonic agitation is applied, heating to 60 C. for ethyl alcohol or 56 C. for acetone. The cathode tube and other subassemblies are dried by blowing with nitrogen gas.
Quintana, Penelope J E; Matt, Georg E; Chatfield, Dale; Zakarian, Joy M; Fortmann, Addie L; Hoh, Eunha
2013-09-01
Secondhand smoke contains a mixture of pollutants that can persist in air, dust, and on surfaces for months or longer. This persistent residue is known as thirdhand smoke (THS). Here, we detail a simple method of wipe sampling for nicotine as a marker of accumulated THS on surfaces. We analyzed findings from 5 real-world studies to investigate the performance of wipe sampling for nicotine on surfaces in homes, cars, and hotels in relation to smoking behavior and smoking restrictions. The intraclass correlation coefficient for side-by-side samples was 0.91 (95% CI: 0.87-0.94). Wipe sampling for nicotine reliably distinguished between private homes, private cars, rental cars, and hotels with and without smoking bans and was significantly positively correlated with other measures of tobacco smoke contamination such as air and dust nicotine. The sensitivity and specificity of possible threshold values (0.1, 1, and 10 μg/m(2)) were evaluated for distinguishing between nonsmoking and smoking environments. Sensitivity was highest at a threshold of 0.1 μg/m(2), with 74%-100% of smoker environments showing nicotine levels above threshold. Specificity was highest at a threshold of 10 μg/m(2), with 81%-100% of nonsmoker environments showing nicotine levels below threshold. The optimal threshold will depend on the desired balance of sensitivity and specificity and on the types of smoking and nonsmoking environments. Surface wipe sampling for nicotine is a reliable, valid, and relatively simple collection method to quantify THS contamination on surfaces across a wide range of field settings and to distinguish between nonsmoking and smoking environments.
Cavana, Paola; Peano, Andrea; Petit, Jean-Yanique; Tizzani, Paolo; Perrot, Sébastien; Bensignor, Emmanuel; Guillot, Jacques
2015-08-01
Wipes containing chlorhexidine and azole derivates have been recommended for veterinary use. No study has been published about their activity against Malassezia pachydermatis. To evaluate the in vivo and in vitro activity of wipes soaked in a chlorhexidine, climbazole and Tris-EDTA solution against Malassezia pachydermatis. Five research colony shar-pei dogs. Wipes were applied once daily onto the left axilla, left groin and perianal area (protocol A), and twice daily on the right axilla, right groin and umbilical region (protocol B) for 3 days. In vivo activity was evaluated by quantifying Malassezia colonies through contact plates on the selected body areas before and after wipe application. The activity of the solution in which the wipes were soaked was assessed in vitro by contact tests following the European Standard UNI EN 1275 guidelines. Samples collected after wipe application showed a significant and rapid reduction of Malassezia yeast CFU. No significant difference in the Malassezia reduction was found between protocols A and B. In vitro assay showed 100% activity against Malassezia yeasts after a 15 min contact time with the wipe solution. Wipes containing chlorhexidine, climbazole and Tris-EDTA substantially reduced the M. pachydermatis population on the skin of dogs. The results, although this was an uncontrolled study performed on a small number of dogs, suggest that these wipes may be useful for topical therapy of Malassezia dermatitis involving the lips, paws, perianal area and skin folds. © 2015 ESVD and ACVD.
Disinfecting the iPad: evaluating effective methods.
Howell, V; Thoppil, A; Mariyaselvam, M; Jones, R; Young, H; Sharma, S; Blunt, M; Young, P
2014-06-01
Tablet computers are increasingly used in healthcare, but they may carry nosocomial pathogens. There are few data available on how to clean an iPad effectively for use in the clinical setting. We aimed to identify the most effective method of decontaminating the Apple iPad, without causing damage, and establish the duration of any residual effect. Following contamination with a microbial broth (meticillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococcus (VRE) and Clostridium difficile), we examined efficacy of iPad disinfection in the laboratory using six different disinfectant wipes: Sani-Cloth CHG 2% (chlorhexidine 2%/alcohol 70%), Clorox, Tristel, Trigene, soap and water, and plain cloth. Following cleaning, iPads were recontaminated to examine residual activity. After 480 Sani-Cloth CHG 2% disinfecting episodes, functional and visual analysis of iPads was performed by blinded subjects. With the exception of Clostridium difficile, Sani-Cloth CHG 2% and Clorox wipes were most effective against MRSA and VRE, and they were significantly better than the Apple-recommended plain cloth (P ≤ 0.001). A substantial residual antimicrobial effect was seen for >6h after wiping the iPad with Sani-Cloth CHG 2% despite repeated recontamination and without further disinfection. The functionality or visual appearance of the iPad was not damaged by repeated use of Sani-Cloth CHG 2% wipes. Sani-Cloth CHG 2% wipes effectively disinfect the iPad against MRSA and VRE, with a residual antibacterial effect and without causing damage. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Hammond, Duane; Garcia, Alberto; Feng, H Amy
2011-07-01
A utility-scale wind turbine blade manufacturing plant requested assistance from the National Institute for Occupational Safety and Health (NIOSH) in controlling worker exposures to styrene at a plant that produced 37 and 42 m long fiber-reinforced wind turbine blades. The plant requested NIOSH assistance because previous air sampling conducted by the company indicated concerns about peak styrene concentrations when workers entered the confined space inside of the wind turbine blade. NIOSH researchers conducted two site visits and collected personal breathing zone and area air samples while workers performed the wind turbine blade manufacturing tasks of vacuum-assisted resin transfer molding (VARTM), gelcoating, glue wiping, and installing the safety platform. All samples were collected during the course of normal employee work activities and analyzed for styrene using NIOSH Method 1501. All sampling was task based since full-shift sampling from a prior Occupational Safety and Health Administration (OSHA) compliance inspection did not show any exposures to styrene above the OSHA permissible exposure limit. During the initial NIOSH site visit, 67 personal breathing zone and 18 area air samples were collected while workers performed tasks of VARTM, gelcoating, glue wipe, and installation of a safety platform. After the initial site visit, the company made changes to the glue wipe task that eliminated the need for workers to enter the confined space inside of the wind turbine blade. During the follow-up site visit, 12 personal breathing zone and 8 area air samples were collected from workers performing the modified glue wipe task. During the initial site visit, the geometric means of the personal breathing zone styrene air samples were 1.8 p.p.m. (n = 21) for workers performing the VARTM task, 68 p.p.m. (n = 5) for workers installing a safety platform, and 340 p.p.m. (n = 14) for workers performing the glue wipe task, where n is the number of workers sampled for a given mean result. Gelcoating workers included job categories of millers, gelcoat machine operators, and gelcoaters. Geometric mean personal breathing zone styrene air samples were 150 p.p.m. (n = 6) for millers, 87 p.p.m. (n = 2) for the gelcoat machine operators, and 66 p.p.m. (n = 19) for gelcoaters. The geometric mean of the personal breathing zone styrene air samples from the glue wipe task measured during the follow-up site visit was 31 p.p.m. (n = 12). The closed molding VARTM process was very effective at controlling worker exposures to styrene. Personal breathing zone styrene air samples were reduced by an order of magnitude after changes were made to the glue wipe task. The company used chemical substitution to eliminate styrene exposure during the installation of the safety platform. Recommendations were provided to reduce styrene concentrations during gelcoating.
Comparison of Wipe Materials and Wetting Agents for Pesticide Residue Collection from Hard Surfaces
Deziel, Nicole C.; Viet, Susan M.; Rogers, John W.; Camann, David E.; Marker, David A.; Heikkinen, Maire S. A.; Yau, Alice Y.; Stout, Daniel M.; Dellarco, Michael
2011-01-01
Different wipe materials and wetting agents have been used to collect pesticide residues from surfaces, but little is known about their comparability. To inform the selection of a wipe for the National Children’s Study, the analytical feasibility, collection efficiency, and precision of Twillwipes wetted with isopropanol (TI), Ghost Wipes (GW), and Twillwipes wetted with water (TW), and were evaluated. Wipe samples were collected from stainless steel surfaces spiked with high and low concentrations of 27 insecticides, including organochlorines, organophosphates, and pyrethroids. Samples were analyzed by GC/MS/SIM. No analytical interferences were observed for any of the wipes. The mean percent collection efficiencies across all pesticides for the TI, GW, and TW were 69.3%, 31.1%, and 10.3% at the high concentration, respectively, and 55.6%, 22.5%, and 6.9% at the low concentration, respectively. The collection efficiencies of the TI were significantly greater than that of GW or TW (p<0.0001). Collection efficiency also differed significantly by pesticide (p<0.0001) and spike concentration (p<0.0001). The pooled coefficients of variation (CVs) of the collection efficiencies for the TI, GW, and TW at high concentration were 0.08, 0.17, and 0.24, respectively. The pooled CV of the collection efficiencies for the TI, GW, and TW at low concentration were 0.15, 0.19, and 0.36, respectively. The TI had significantly lower CVs than either of the other two wipes (p=0.0008). Though the TI was superior in terms of both accuracy and precision, it requires multiple preparation steps, which could lead to operational challenges in a large-scale study. PMID:21816452
Willison, Stuart A
2012-12-28
Degradation products arising from nitrogen mustard chemical warfare agent were deposited on common urban surfaces and determined via surface wiping, wipe extraction, and liquid chromatography–tandem mass spectrometry detection. Wipes investigated included cotton gauze, glass fiber filter, non-woven polyester fiber and filter paper, and surfaces included several porous (vinyl tile, painted drywall, wood) and mostly non-porous (laminate, galvanized steel, glass) surfaces. Wipe extracts were analyzed by ultra-high pressure liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) and compared with high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) results. An evaluation of both techniques suggests UPLC–MS/MS provides a quick and sensitive analysis of targeted degradation products in addition to being nearly four times faster than a single HPLC run, allowing for greater throughput during a wide-spread release concerning large-scale contamination and subsequent remediation events. Based on the overall performance of all tested wipes, filter paper wipes were selected over other wipes because they did not contain interferences or native species (TEA and DEA) associated with the target analytes, resulting in high percent recoveries and low background levels during sample analysis. Other wipes, including cotton gauze, would require a pre-cleaning step due to the presence of large quantities of native species or interferences of the targeted analytes. Percent recoveries obtained from a laminate surface were 47–99% for all nitrogen mustard degradation products. The resulting detection limits achieved from wipes were 0.2 ng/cm(2) for triethanolamine (TEA), 0.03 ng/cm(2) for N-ethyldiethanolamine (EDEA), 0.1 ng/cm(2) for N-methyldiethanolamine (MDEA), and 0.1 ng/cm(2) for diethanolamine (DEA).
Surface Analysis of Nerve Agent Degradation Products by ...
Report This sampling and analytical procedure was developed and applied by a single laboratory to investigate nerve agent degradation products, which may persist at a contaminated site, via surface wiping followed by analytical characterization. The performance data presented demonstrate the fitness-for-purpose regarding surface analysis in that single laboratory. Surfaces (laminate, glass, galvanized steel, vinyl tile, painted drywall and treated wood) were wiped with cotton gauze wipes, sonicated, extracted with distilled water, and filtered. Samples were analyzed with direct injection electrospray ionization liquid chromatography tandem mass spectrometry (ESI-LC/MS/MS) without derivatization. Detection limit data were generated for all analytes of interest on a laminate surface. Accuracy and precision data were generated from each surface fortified with these analytes.
Sterling, D A; Lewis, R D; Luke, D A; Shadel, B N
2000-06-01
Dust wipe samples collected in the field were tested by nondestructive X-ray fluorescence (XRF) followed by laboratory analysis with flame atomic absorption spectrophotometry (FAAS). Data were analyzed for precision and accuracy of measurement. Replicate samples with the XRF show high precision with an intraclass correlation coefficient (ICC) of 0.97 (P<0.0001) and an overall coefficient of variation of 11.6%. Paired comparison indicates no statistical difference (P=0.272) between XRF and FAAS analysis. Paired samples are highly correlated with an R(2) ranging between 0.89 for samples that contain paint chips and 0.93 for samples that do not contain paint chips. The ICC for absolute agreement between XRF and laboratory results was 0.95 (P<0.0001). The relative error over the concentration range of 25 to 14,200 microgram Pb is -12% (95% CI, -18 to -5). The XRF appears to be an excellent method for rapid on-site evaluation of dust wipes for clearance and risk assessment purposes, although there are indications of some confounding when paint chips are present. Copyright 2000 Academic Press.
Dermal exposure studies incorporating urinary biomarker measurements are complicated because dermal sampling may intercept or remove the target chemical before it is absorbed. A hand wipe subsampling method has been developed using polyurethane foam-tipped (PUF) swabs to minim...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez, Tammy Ann
Technical Area-18 (TA-18), also known as Pajarito Site, is located on Los Alamos National Laboratory property and has historic buildings that will be included in the Manhattan Project National Historic Park. Characterization studies of metal contamination were needed in two of the four buildings that are on the historic registry in this area, a “battleship” bunker building (TA-18-0002) and the Pond cabin (TA-18-0029). However, these two buildings have been exposed to the elements, are decades old, and have porous and rough surfaces (wood and concrete). Due to these conditions, it was questioned whether standard wipe sampling would be adequate tomore » detect surface dust metal contamination in these buildings. Thus, micro-vacuum and surface wet wipe sampling techniques were performed side-by-side at both buildings and results were compared statistically. A two-tail paired t-test revealed that the micro-vacuum and wet wipe techniques were statistically different for both buildings. Further mathematical analysis revealed that the wet wipe technique picked up more metals from the surface than the microvacuum technique. Wet wipes revealed concentrations of beryllium and lead above internal housekeeping limits; however, using an yttrium normalization method with linear regression analysis between beryllium and yttrium revealed a correlation indicating that the beryllium levels were likely due to background and not operational contamination. PPE and administrative controls were implemented for National Park Service (NPS) and Department of Energy (DOE) tours as a result of this study. Overall, this study indicates that the micro-vacuum technique may not be an efficient technique to sample for metal dust contamination.« less
Tebbutt, G. M.
1988-01-01
A comparison of five methods of cleaning Formica surfaces contaminated with bacteria dried in milk has been carried out. A standardized procedure was developed, and impression plates were found to be at least as sensitive as a swab-rinse method for detecting bacteria on the surfaces. The most satisfactory results were obtained with one type of disposable alcohol-impregnated wipe and with a detergent/hypochlorite solution applied with paper. A reusable cloth impregnated with disinfectant initially performed well against all test organisms, but was less reliable against Staphylococcus aureus and Streptococcus faecalis, after the cloth had been used and rinsed several times. The importance of introducing methods to reduce the high risk of cross-contamination presently associated with the use of wiping cloths in catering premises is stressed. PMID:3141202
Langkjaer, L; Brange, J; Grodsky, G M; Guy, R H
1998-01-23
The aim of this study was to investigate the influence of association state and net charge of human insulin analogues on the rate of iontophoretic transport across hairless mouse skin, and the effect of different skin pretreatments on said transport. No insulin flux was observed with anodal delivery probably because of degradation at the Ag/AgCl anode. The flux during cathodal iontophoresis through intact skin was insignificant for human hexameric insulin, and only low and variable fluxes were observed for monomeric insulins. Using stripped skin on the other hand, the fluxes of monomeric insulins with two extra negative charges were 50-100 times higher than that of hexameric human insulin. Introducing three additional charges led to a further 2-3-fold increase in flux. Wiping the skin gently with absolute alcohol prior to iontophoresis resulted in a 1000-fold increase in transdermal transport of insulin relative to that across untreated skin, i.e. to almost the same level as stripping the skin. The alcohol pretreatment reduced the electrical resistance of the skin, presumably by lipid extraction. In conclusion, monomeric insulin analogues with at least two extra negative charges can be iontophoretically delivered across hairless mouse skin, whereas insignificant flux is observed with human, hexameric insulin. Wiping the skin with absolute alcohol prior to iontophoresis gave substantially improved transdermal transport of monomeric insulins resulting in clinically relevant delivery rates for basal treatment.
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
Hand hygiene: product preference and compliance.
Tanner, Judith; Mistry, Neetesh
Hospitals are trying to improve patient hand hygiene by providing handwashing products at the bedside. Patients' compliance with handwashing depends on their satisfaction with hygiene products but no one has looked at which products patients prefer. Research on this will help hospitals target hand hygiene more appropriately and effectively. To explore patient satisfaction with hand hygiene products and identify those that are most popular. Two hundred patients were given five hand hygiene products to evaluate. These represent the interventions most widely used by patients in hospitals: alcohol foams, alcohol wipes, wet cloths with antiseptic solutions, bowls of soapy water and mobile sinks. Alcohol foam achieved the highest mean satisfaction score and was significantly more popular than the other products. Alcohol foam was the most popular choice regardless of age, sex, dexterity, mobility and religion.
Genital region cleansing wipes: Effects on urine culture contamination.
Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa
2017-01-30
Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.
Utility of snout wipe samples for influenza A virus surveillance in exhibition swine populations
Edwards, Jody L; Nelson, Sarah W; Workman, Jeffrey D; Slemons, Richard D; Szablewski, Christine M; Nolting, Jacqueline M; Bowman, Andrew S
2014-01-01
Background Sporadic influenza A virus (IAV) outbreaks in humans and swine have resulted from commingling of large numbers of people and pigs at agricultural fairs in the United States. Current antemortem IAV surveillance strategies in swine require collecting nasal swabs, which entails restraining pigs with snares. Restraint is labor-intensive for samplers, stressful for pigs, and displeasing to onlookers because pigs often resist and vocalize. Objective To evaluate the utility of snout wipes in exhibition swine as a method to make IAV surveillance efforts less intrusive, less labor-intensive, and more widely accepted among pig owners and exhibition officials. Methods Three materials (rayon/polyester gauze, cotton gauze, and Swiffer® Sweeper dry cloths) were inoculated with IAV, and viral recoveries from these materials were quantified using qRT-PCR and TCID50 assays. In a field trial, paired cotton gauze snout wipes and gold standard polyester-tipped nasal swabs were collected from 553 pigs representing 29 agricultural fairs and the qualitative results of rRT-PCR and viral isolation were compared. Results and Conclusions Viral recoveries from potential snout wipe materials ranged from 0·26 to 1·59 log10 TCID50/ml less than that of the positive control in which no substrate was included; rayon/polyester gauze performed significantly worse than the other materials. In the field, snout wipes and nasal swabs had high levels of agreement for both rRT-PCR detection and virus isolation. Although further investigation and refinement of the sampling method is needed, results indicate that snout wipes will facilitate convenient and undisruptive IAV surveillance in pigs at agricultural fairs. PMID:25043408
Xie, Mingjie; Wu, Yaoxing; Little, John C; Marr, Linsey C
2016-01-01
This work focuses on the mass content of plasticizers in children's backpacks and toys, and their mass transfer from product surfaces to cotton wipes. The mass content of plasticizers in six backpacks and seven toys was measured by extracting them in tetrahydrofuran. Bis(2-ethylhexyl) terephthalate (DEHT) was the most common plasticizer, dominating the composition of plasticizers in four backpacks (average mass content in product polyvinyl chloride, 5.38 ± 1.98%-25.5 ± 3.54%) and six plastic toys (8.17 ± 1.85%-21.2 ± 1.11%). The surface of each product was wiped with three dry and three wet (by isopropanol) cotton wipes, so as to evaluate the mass transfer of plasticizers to clothing and human skin, respectively. DEHT was the most common plasticizer detected on wipe samples. There were strong correlations (backpacks r=0.90; plastic toys r=0.96) between average mass transfer of DEHT to wet wipes and its average mass content in the product. The mass transfers of the five dominant plasticizers in one backpack to both dry and wet wipes were also correlated (both r=1.00) with their mass contents. These results suggest that the mass transfer of plasticizers from products to clothing or human skin is strongly associated with their mass content.
Infection Control in Air Force Dental Clinics (Second Edition),
1983-11-01
glutaraldehydes, but its disadvantages preclude its usefulness as a routine disinfectant. Sodium Hypochlorite (Chlorine) Sodium hypochlorite is thought...to oxidize microbial enzymes and cell-wall components. The most economical source for sodium hypochlorite is common household bleach. A 1% solution (1...wiped, after an appropriate contact time, with a gauze wet with water, 70% alcohol, or 1% sodium hypochlorite . Intermediate levels of disinfection can
Sampling scheme for pyrethroids on multiple surfaces on commercial aircrafts.
Mohan, Krishnan R; Weisel, Clifford P
2010-06-01
A wipe sampler for the collection of permethrin from soft and hard surfaces has been developed for use in aircraft. "Disinsection" or application of pesticides, predominantly pyrethrods, inside commercial aircraft is routinely required by some countries and is done on an as-needed basis by airlines resulting in potential pesticide dermal and inhalation exposures to the crew and passengers. A wipe method using filter paper and water was evaluated for both soft and hard aircraft surfaces. Permethrin was analyzed by GC/MS after its ultrasonication extraction from the sampling medium into hexane and volume reduction. Recoveries, based on spraying known levels of permethrin, were 80-100% from table trays, seat handles and rugs; and 40-50% from seat cushions. The wipe sampler is easy to use, requires minimum training, is compatible with the regulations on what can be brought through security for use on commercial aircraft, and readily adaptable for use in residential and other settings.
Comparative Evaluation of Vacuum-based Surface Sampling ...
Journal Article Following a biological contamination incident, collection of surface samples is necessary to determine the extent and level of contamination, and to deem an area safe for reentry upon decontamination. Current sampling strategies targeting Bacillus anthracis spores prescribe vacuum-based methods for rough and/or porous surfaces. In this study, four commonly-used B. anthracis spore sampling devices (vacuum socks, 37 mm 0.8 µm MCE filter cassettes, 37 mm 0.3 µm PTFE filter cassettes, and 3MTM forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. The vacuum sock device was evaluated at two sampling speeds (slow and fast), resulting in five total methods evaluated. Aerosolized spores (~105 cm-2) of a surrogate Bacillus species (Bacillus atrophaeus) were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each of the three material types. In addition, stainless steel (i.e., nonporous) surfaces inoculated simultaneously were sampled with pre-moistened wipes. Recoveries from wipes of steel surfaces were utilized to verify the inoculum, and to normalize vacuum-based recoveries across trials. Recovery (CFU cm-2) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Relative recoveries were compared by one-way and three-way ANOVA. Data analysis by one-
NASA Astrophysics Data System (ADS)
Chen, F.; La Duc, M. T.; Baker, A.; Koukol, R.; Barengoltz, J.; Kern, R.; Venkateswaran, K.
2001-12-01
Europa has attracted much attention as evidence suggests the presence of a liquid ocean beneath this Jupiter moon's frozen crust. Such an environment might be conducive to the origins of life. Since robotic exploration of Europa is being planned, it becomes crucial to prepare for bio-burden reduction of hardware assembled for Europa missions to avoid contamination of Europa's pristine environment. In this study, we examined the microbial diversity of samples collected from two flight-ready circuit boards and their assembly facility. Also, because Jupiter's strong radiation environment may be able to reduce the viable microbial contamination on flight components, we have also studied the effects of radiation on microbial communities found to be associated with the space-flight hardware and/or present in the assembly facility. Surface samples thought to be representative of considerable human contact were collected from two circuit boards and various locations within the assembly facility using polyester swabs (swab samples). Likewise, sterile wipes were used to sample a shelf above the workstation where the circuit boards were assembled and the floor of the facility (wipe samples). The swab and wipe samples were pooled separately and divided into two halves, one of which was irradiated with 1Mrad gamma radiation for 5.5 hours, the other was not irradiated. About 1.2x104 and 6x104 CFUs/m2 cultivable microbes were detected in the swab and wipe samples, respectively. Radiation proved effective in inhibiting the growth of most microbes. Further characterization of the bacterial colonies observed in the irradiated swab and wipe samples is necessary to determine the degree of the radiation resistance. The16S rDNA sequence analysis of the cultivable microbes indicated that the assembly facility consists mostly of the members of actinobacteria, corynebacteria and pseudomonads. However, the swab samples that include the circuit boards were predominantly populated with Bacillus and Staphylococcus. Molecular microbial diversity was also studied by cloning the 16S rDNA PCR fragment from the samples. The non-irradiated swab samples were largely populated by species of Exiguobacter and Bacillus whereas the irradiated swab samples were dominated by Bacillus and E. coli. Radiation damage of microorganisms was also investigated by epifluorescence microscopy. In summary, our study has shown that gamma radiation can inhibit the growth of most of the cultivable microbes, but preliminary results suggest that radiation such as this has little adverse effect on the DNA molecules of these microorganisms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paik, Samuel Y.; Epperson, Patrick M.; Kasper, Kenneth M.
Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measuresmore » in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2, for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.« less
Paik, Samuel Y; Epperson, Patrick M; Kasper, Kenneth M
2017-06-01
This article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. All the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.
Paik, Samuel Y.; Epperson, Patrick M.; Kasper, Kenneth M.
2017-02-28
Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measuresmore » in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2, for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.« less
Investigation of the Persistence of Nerve Agent Degradation ...
Journal Article The persistence of chemical warfare nerve agent degradation analytes on surfaces is important for reasons ranging from indicating the presence of nerve agent on that surface to environmental restoration of a site after nerve agent release. This study investigates the persistence of several chemical warfare nerve agent degradation analytes on a number of indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Multiple commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces, including several porous/permeable and largely nonporous/impermeable surfaces, were investigated to determine recoveries from these indoor surface materials. Wipe extracts were analyzed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and compared with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) results. UPLC provides a sensitive separation of targeted degradation analytes in addition to being nearly four times faster than HPLC, allowing for greater throughput during a widespread release concerning large-scale contamination and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), 61-91 % for ethyl methylphosphonate (EMPA), and 60-98% for pinacolyl methylphosphona
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sterling, D.A.; Roegner, K.C.; Lewis, R.D.
Childhood exposure to lead has been demonstrated to result in health effects and lead-contaminated household dust is a primary exposure source. There is a need to establish reliable methods for sampling surfaces to determine levels of lead contamination. Three vacuums (HVS3, GS80, and MVM) and one wipe method were evaluated for the collection of household floor dust under field sampling conditions within a Superfund site and demographically similar control area. Side-by-side floor samples were taken from three locations within 41 randomly selected households between August and September 1995: a child's bedroom, primary play area, and primary entrance. Analysis was performedmore » to assess the relative collection performance of each sampler, spatial distribution of lead within a household, and correlation of lead loading with observed blood lead level, and to determine if discrete or composites samples were more predictive of blood lead levels. Approximately 90% of the floor surfaces were carpeted. The rank order of sampling methods from greatest to lowest collection efficiency was HVS3 > G80 > wipe > MVM. The HVS3 had the highest level of precision (CV = 0.05), with the GS80 and wipe precisions 0.48 and 0.053, respectively.« less
Huitema, A. D. R.; Bakker, E. N.; Douma, J. W.; Schimmel, K. J. M.; van Weringh, G.; de Wolf, P. J.; Schellens, J. H. M.; Beijnen, J. H.
2007-01-01
Objective: To develop, validate, and apply a method for the determination of platinum contamination, originating from cisplatinum, oxaliplatinum, and carboplatinum. Methods: Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine platinum in wipe samples. The sampling procedure and the analytical conditions were optimised and the assay was validated. The method was applied to measure surface contamination in seven Dutch hospital pharmacies. Results: The developed method allowed reproducible quantification of 0.50 ng l−1 platinum (5 pg/wipe sample). Recoveries for stainless steel and linoleum surfaces ranged between 50.4 and 81.4% for the different platinum compounds tested. Platinum contamination was reported in 88% of the wipe samples. Although a substantial variation in surface contamination of the pharmacies was noticed, in most pharmacies, the laminar-airflow (LAF) hoods, the floor in front of the LAF hoods, door handles, and handles of service hatches showed positive results. This demonstrates that contamination is spread throughout the preparation rooms. Conclusion: We developed and validated an ultra sensitive and reliable ICP-MS method for the determination of platinum in surface samples. Surface contamination with platinum was observed in all hospital pharmacies sampled. The interpretation of these results is, however, complicated. PMID:17377802
Hendry, Emma; Conway, Barbara; Worthington, Tony
2012-10-30
Effective surface disinfection is a fundamental infection control strategy within healthcare. This study assessed the antimicrobial efficacy of novel biocide formulations comprising 5% and 2% eucalyptus oil (EO) combined with 2% chlorhexidine digluconate (CHG) and 70% isopropyl alcohol (IPA) contained within a wipe. The efficacy of this novel antimicrobial formulation to remove and eliminate methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli and Candida albicans from steel surfaces was investigated. Adpression studies of pre-contaminated wipes were also utilised to assess their potential to induce cross-contamination between hard surfaces. Furthermore, the bactericidal nature of the EO-formulation was established in addition to time-kill. The EO-containing formulations demonstrated bactericidal antimicrobial efficacy against all microorganisms and did not induce surface cross-contamination. There was no significant difference (p < 0.05) between the 5% and 2% EO formulations in their ability to remove microorganisms from steel surfaces, however both significantly (p < 0.05) removed more than the control formulations. Microbial biofilms were eliminated within 10 min (p < 0.05) when exposed to the EO formulations. Our novel EO-formulation demonstrated rapid antimicrobial efficacy for potential disinfection and elimination of microbial biofilms from hard surfaces and may therefore be a useful adjunct to current infection control strategies currently employed within healthcare facilities.
Hendry, Emma; Conway, Barbara; Worthington, Tony
2012-01-01
Effective surface disinfection is a fundamental infection control strategy within healthcare. This study assessed the antimicrobial efficacy of novel biocide formulations comprising 5% and 2% eucalyptus oil (EO) combined with 2% chlorhexidine digluconate (CHG) and 70% isopropyl alcohol (IPA) contained within a wipe. The efficacy of this novel antimicrobial formulation to remove and eliminate methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli and Candida albicans from steel surfaces was investigated. Adpression studies of pre-contaminated wipes were also utilised to assess their potential to induce cross-contamination between hard surfaces. Furthermore, the bactericidal nature of the EO-formulation was established in addition to time-kill. The EO-containing formulations demonstrated bactericidal antimicrobial efficacy against all microorganisms and did not induce surface cross-contamination. There was no significant difference (p < 0.05) between the 5% and 2% EO formulations in their ability to remove microorganisms from steel surfaces, however both significantly (p < 0.05) removed more than the control formulations. Microbial biofilms were eliminated within 10 min (p < 0.05) when exposed to the EO formulations. Our novel EO-formulation demonstrated rapid antimicrobial efficacy for potential disinfection and elimination of microbial biofilms from hard surfaces and may therefore be a useful adjunct to current infection control strategies currently employed within healthcare facilities. PMID:23203047
Mobile Phones as a Potential Vehicle of Infection in a Hospital Setting.
Chao Foong, Yi; Green, Mark; Zargari, Ahmad; Siddique, Romana; Tan, Vanessa; Brain, Terry; Ogden, Kathryn
2015-01-01
The objective of this article is to investigate the potential role of mobile phones as a reservoir for bacterial colonization and the risk factors for bacterial colonization in a hospital setting. We screened 226 staff members at a regional Australian hospital (146 doctors and 80 medical students) between January 2013 and March 2014. The main outcomes of interest were the types of microorganisms and the amount of contamination of the mobile phones. This study found a high level of bacterial contamination (n = 168/226, 74%) on the mobile phones of staff members in a tertiary hospital, with similar organisms isolated from the staff member's dominant hand and mobile phones. While most of the isolated organisms were normal skin flora, a small percentage were potentially pathogenic (n = 12/226, 5%). Being a junior medical staff was found to be a risk factor for heavy microbial growth (OR 4.00, 95% CI 1.54, 10.37). Only 31% (70/226) of our participants reported cleaning their phones routinely, and only 21% (47/226) reported using alcohol containing wipes on their phones. This study demonstrates that mobile phones are potentially vehicles for pathogenic bacteria in a hospital setting. Only a minority of our participants reported cleaning their phones routinely. Disinfection guidelines utilizing alcohol wipes should be developed and implemented.
Hernon-Kenny, Laura A; Behringer, Deborah L; Crenshaw, Michael D
2016-05-01
Comparison of solvent-wetted gauze with body paint, a peelable surface sampling media, for the sampling of the chemical warfare agents VX and sulfur mustard from nine surfaces was performed. The nine surfaces sampled are those typical of interior public venues and include smooth, rough, porous, and non-porous surfaces. Overall, solvent-wetted gauze (wipes) performed better for the recovery of VX from non-porous surfaces while body paint (BP) performed better for the porous surfaces. The average percent VX recoveries using wipes and BP, respectively, are: finished wood flooring, 86.2%, 71.4%; escalator handrail, 47.3%, 26.7%; stainless steel, 80.5%, 56.1%; glazed ceramic tile, 81.8%, 44.9%; ceiling tile, 1.77%, 13.1%; painted drywall 7.83%, 21.1%; smooth cement, 0.64%, 10.3%; upholstery fabric, 24.6%, 23.1%; unfinished wood flooring, 9.37%, 13.1%. Solvent-wetted gauze performed better for the recovery of sulfur mustard from three of the relatively non-porous surfaces while body paint performed better for the more porous surfaces. The average percent sulfur mustard recoveries using wipes and BP, respectively, are: finished wood flooring, 30.2%, 2.97%; escalator handrail, 4.40%, 4.09%; stainless steel, 21.2%, 3.30%; glazed ceramic tile, 49.7%, 16.7%; ceiling tile, 0.33%, 11.1%; painted drywall 2.05%, 10.6%; smooth cement, 1.20%, 35.2%; upholstery fabric, 7.63%, 6.03%; unfinished wood flooring, 0.90%, 1.74%. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Impact of Processing Method on Recovery of Bacteria from Wipes Used in Biological Surface Sampling
Olson, Nathan D.; Filliben, James J.; Morrow, Jayne B.
2012-01-01
Environmental sampling for microbiological contaminants is a key component of hygiene monitoring and risk characterization practices utilized across diverse fields of application. However, confidence in surface sampling results, both in the field and in controlled laboratory studies, has been undermined by large variation in sampling performance results. Sources of variation include controlled parameters, such as sampling materials and processing methods, which often differ among studies, as well as random and systematic errors; however, the relative contributions of these factors remain unclear. The objective of this study was to determine the relative impacts of sample processing methods, including extraction solution and physical dissociation method (vortexing and sonication), on recovery of Gram-positive (Bacillus cereus) and Gram-negative (Burkholderia thailandensis and Escherichia coli) bacteria from directly inoculated wipes. This work showed that target organism had the largest impact on extraction efficiency and recovery precision, as measured by traditional colony counts. The physical dissociation method (PDM) had negligible impact, while the effect of the extraction solution was organism dependent. Overall, however, extraction of organisms from wipes using phosphate-buffered saline with 0.04% Tween 80 (PBST) resulted in the highest mean recovery across all three organisms. The results from this study contribute to a better understanding of the factors that influence sampling performance, which is critical to the development of efficient and reliable sampling methodologies relevant to public health and biodefense. PMID:22706055
Hines, Cynthia J; Jackson, Matthew V; Christianson, Annette L; Clark, John C; Arnold, James E; Pretty, Jack R; Deddens, James A
2017-11-01
For decades, bisphenol A (BPA) has been used in making polycarbonate, epoxy, and phenolic resins and certain investment casting waxes, yet published exposure data are lacking for U.S. manufacturing workers. In 2013-2014, BPA air and hand exposures were quantified for 78 workers at six U.S. companies making BPA or BPA-based products. Exposure measures included an inhalable-fraction personal air sample on each of two consecutive work days (n = 146), pre- and end-shift hand wipe samples on the second day (n = 74 each), and surface wipe samples (n = 88). Potential determinants of BPA air and end-shift hand exposures (after natural log transformation) were assessed in univariate and multiple regression mixed models. The geometric mean (GM) BPA air concentration was 4.0 µg/m 3 (maximum 920 µg/m 3 ). The end-shift GM BPA hand level (26 µg/sample) was 10-times higher than the pre-shift level (2.6 µg/sample). BPA air and hand exposures differed significantly by industry and job. BPA air concentrations and end-shift hand levels were highest in the BPA-filled wax manufacturing/reclaim industry (GM Air = 48 µg/m 3 , GM Hand-End = 130 µg/sample) and in the job of working with molten BPA-filled wax (GM Air = 43 µg/m 3 , GM Hand-End = 180 µg/sample), and lowest in the phenolic resins industry (GM Air = 0.85 µg/m 3 , GM Hand-End = 0.43 µg/sample) and in the job of flaking phenolic resins (GM AIR = 0.62 µg/m 3 , GM Hand-End = 0.38 µg/sample). Determinants of increased BPA air concentration were industry, handling BPA containers, spilling BPA, and spending ≥50% of the shift in production areas; increasing age was associated with lower air concentrations. BPA hand exposure determinants were influenced by high values for two workers; for all other workers, tasks involving contact with BPA-containing materials and spending ≥50% of the shift in production areas were associated with increased BPA hand levels. Surface wipe BPA levels were significantly lower in eating/office areas (GM = 9.3 µg/100 cm 2 ) than in production areas (GM = 140 µg/100 cm 2 ). In conclusion, worker BPA exposure was associated with tasks and conditions affecting both inhalation and dermal exposure. The potential for BPA-related health effects among these workers is unknown.
NASA Astrophysics Data System (ADS)
Viacheslav, Ilyin; Korshunov, Denis
Recovery of various organic wastes in space flight is an actual problem of modern astronautics and future interplanetary missions. Currently, organic waste are incinerated in the dense layers of the Earth's atmosphere in cargo containers. However, this method of anthropogenic waste treatment is not environmentally compatible with future interplanetary missions, and is not suitable due to planetary quarantine requirements. Furthermore, the maintaining of a closed ecosystem in spaceship is considered as one of the main ways of ensuring the food and air crew in the long term fully autonomous space expedition. Such isolated ecosystem is not conceivable without biotransformation of organic waste. In this regard, currently new ways of recycling organic waste are currently developed. The most promising method is a method for processing organic waste using thermophilic anaerobic microbial communities.However, the products of anaerobic fermentation of solid organic materials contain significant amounts of organic impurities, which often give them sour pH. This presents a significant problem because it does not allow to use this fluid as process water without pretreatment. Fermentation products - alcohols, volatile fatty acids other carbonaceous substances must be withdrawn.One way to solve this problem may be the use of microorganisms biodestructors for recycling organic impurities in the products of anaerobic biodegradation Under the proposed approach, the metabolic products (having acidic pH) of primary biotransformation of solid organic materials are used as media for the cultivation of fungi. Thus, cellulosic wastes are recycled in two successive stages. The aim of this work was to test the effectiveness of post-treatment liquid products of biodegradation of hygienic cotton wipes (common type of waste on the ISS) by the fungus Trichoderma viridae under orbital flight. The study was conducted onboard biosatellite Bion -M1, where was placed a bioreactor, designed to carry out the fermentation in space flight. For aerobic post-treatment of substrates remaining after biodegradation of cotton wipe there was selected a strain of the fungus Trihoderma viridae, able to grow at a slightly acid environment , and to bring the pH to neutral values. Bioreactor working volume of 40 ml, where 20 ml of liquid subjected to post-treatment was placed. Strain Trihoderma viridae, isolated from ISS environment, showed steady growth in terms identical to those of pre- cultivation. Efficiency of purification was assessed using the method of gas chromatography-mass spectrometry comparing the amount and concentration of the volatile organic compounds in the samples. It turned out that the number of compounds detected in the flight sample almost halved compared to the original sample obtained after biodegradation gauze anaerobic bacteria. The total concentration of volatile impurities dropped 6 times. Thus, despite the limited resource of oxygen, due to lack of aeration in the bioreactor strain Trihoderma viridae demonstrated the ability to perform aerobic purification of substrate obtained after anaerobic biodegradation of cotton wipes under orbital flight.
Sampling scheme for pyrethroids on multiple surfaces on commercial aircrafts
MOHAN, KRISHNAN R.; WEISEL, CLIFFORD P.
2015-01-01
A wipe sampler for the collection of permethrin from soft and hard surfaces has been developed for use in aircraft. “Disinsection” or application of pesticides, predominantly pyrethrods, inside commercial aircraft is routinely required by some countries and is done on an as-needed basis by airlines resulting in potential pesticide dermal and inhalation exposures to the crew and passengers. A wipe method using filter paper and water was evaluated for both soft and hard aircraft surfaces. Permethrin was analyzed by GC/MS after its ultrasonication extraction from the sampling medium into hexane and volume reduction. Recoveries, based on spraying known levels of permethrin, were 80–100% from table trays, seat handles and rugs; and 40–50% from seat cushions. The wipe sampler is easy to use, requires minimum training, is compatible with the regulations on what can be brought through security for use on commercial aircraft, and readily adaptable for use in residential and other settings. PMID:19756041
Assessing the Health Effects of Blast Injuries and Embedded Metal Fragments
2017-10-01
isoflurane and open oxygen tank valve (check psi) Prep Vetbond, buprenorphine, 1 ml syringes and #10 scalpel blades In the vivarium, weigh each...with #10 blade over gastrocnemius Inject pellets into muscle tissue using 14 or 16 gauge needle and plunger (one at a time) Repeat incision and...Fluovac canister and record on adsorber canister (dispose of canister at 1400 grams) Clean clippers in Blade Wash, wipe down with isopropyl alcohol, then
Galea, Karen S.; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez
2014-01-01
Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs’ trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods’ comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. PMID:24598941
A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...
Egert, Markus; Späth, Kerstin; Weik, Karoline; Kunzelmann, Heike; Horn, Christian; Kohl, Matthias; Blessing, Frithjof
2015-03-01
Smartphone touchscreens are known as pathogen carriers in clinical environments. However, despite a rapidly growing number of smartphone users worldwide, little is known about bacterial contamination of smartphone touchscreens in non-clinical settings. Such data are needed to better understand the hygienic relevance of these increasingly popular items. Here, 60 touchscreens of smartphones provided by randomly chosen students of a German university were sampled by directly touching them with contact agar plates. The average bacterial load of uncleaned touchscreens was 1.37 ± 0.33 CFU/cm(2). Touchscreens wiped with commercially available microfiber cloths or alcohol-impregnated lens wipes contained significantly less bacteria than uncleaned touchscreens, i.e., 0.22 ± 0.10 CFU/cm(2) and 0.06 ± 0.02 CFU/cm(2), respectively. Bacteria isolated from cleaned and uncleaned touchscreens were identified by means of MALDI Biotyping. Out of 111 bacterial isolates, 56 isolates (50 %) were identified to genus level and 27 (24 %) to species level. The vast majority of the identified bacteria were typical human skin, mouth, lung, and intestinal commensals, mostly affiliated with the genera Staphylococcus and Micrococcus. Five out of 10 identified species were opportunistic pathogens. In conclusion, the touchscreens investigated here showed low bacterial loads and a species spectrum that is typical for frequently touched surfaces in domestic and public environments, the general health risk of which is still under debate.
Forbes, Thomas P; Sisco, Edward; Staymates, Matthew
2018-05-07
Infrared thermal desorption (IRTD) was coupled with direct analysis in real time mass spectrometry (DART-MS) for the detection of both inorganic and organic explosives from wipe collected samples. This platform generated discrete and rapid heating rates that allowed volatile and semivolatile organic explosives to thermally desorb at relatively lower temperatures, while still achieving elevated temperatures required to desorb nonvolatile inorganic oxidizer-based explosives. IRTD-DART-MS demonstrated the thermal desorption and detection of refractory potassium chlorate and potassium perchlorate oxidizers, compounds difficult to desorb with traditional moderate-temperature resistance-based thermal desorbers. Nanogram to sub-nanogram sensitivities were established for analysis of a range of organic and inorganic oxidizer-based explosive compounds, with further enhancement limited by the thermal properties of the most common commercial wipe materials. Detailed investigations and high-speed visualization revealed conduction from the heated glass-mica base plate as the dominant process for heating of the wipe and analyte materials, resulting in thermal desorption through boiling, aerosolization, and vaporization of samples. The thermal desorption and ionization characteristics of the IRTD-DART technique resulted in optimal sensitivity for the formation of nitrate adducts with both organic and inorganic species. The IRTD-DART-MS coupling and IRTD in general offer promising explosive detection capabilities to the defense, security, and law enforcement arenas.
Assessment of arsenic surface contamination in a museum anthropology department.
Gribovich, Andrey; Lacey, Steven; Franke, John; Hinkamp, David
2013-02-01
To assess potential arsenic (As) contamination of work surfaces to improve upon the control strategy at an anthropology department in a large natural history museum. Work practices were observed and control strategy reviewed to inform an occupational hygiene assessment strategy utilizing surface wipe sampling. A total of 35 sampling targets were identified, focusing on surfaces that receive high touch traffic, including workstations, artifact transport carts, and elevator buttons. Arsenic sampling and analysis were performed using reference method Occupational Safety and Health Administration ID-125G. Four of the sampling areas returned detectable levels of As, ranging from 0.052 to 0.350 μg/100 cm. Workplace observations and wipe sampling data enabled the development of recommendations to help to further reduce potential occupational exposure to As. Continuous reduction of surface contamination is prudent for known human carcinogens.
NASA Astrophysics Data System (ADS)
Pingitore, N. E.; Clague, J.; Amaya, M. A.
2006-12-01
Understanding the interplay of indoor and outdoor sources of lead in an urban setting is one foundation in establishing risk for lead exposure in children in our cities. A household may be the source for lead contamination due to the deterioration of interior lead-based paint, or a sink if lead particles are tracked or blown into the home from such potential ambient sources as yard soil or urban street dust. In addressing this issue, X-Ray Absorption Spectroscopy (XAS) presents the opportunity to directly and quantitatively speciate lead at low concentrations in bulk samples. We performed XAS analyses on dust wipes from window sills or floors from 8 houses that exceeded Federal standards for lead in dust. We entered these data into a Principal Components Analysis (PCA) that also included El Paso environmental samples: lead-based paints, soils, and airborne particulate matter. A simple two-component mixing system accounted for more than 95% of the variance of this data set. Paint and lead oxide appear to be the principal components, with all the samples falling in a compositional range from pure paint to 75% paint, 25% lead oxide. Note that several different lead compounds are possible constituents of a given lead-based paint. The paints spread from one end out along perhaps a fifth of the range of the compositional axis, followed closely, but not overlapped, by the soil samples, which covered the remainder of the compositional range. Two of the dust wipes plotted within the paint range, and the remaining 6 dust wipes plotted randomly through the soil range. Samples of airborne particulate matter plotted in both the paint and soil ranges. These observations suggest that the lead on most of the dust wipes originated outside the house, probably from deteriorated exterior lead-based paint deposited in adjacent yards. This paint mixed with lead oxide present in the soil and entered the houses by the airborne route. The probable source of the oxide in the soil is former airborne deposition of automobile exhaust from leaded gasoline (lead halides quickly react to form oxide). The dust wipes that fall within the compositional range of the paints may have originated from deterioration of interior paint. The XAS findings are consistent with our tests of several hundred houses in El Paso: most of the wipes that exceeded Federal lead standards came from houses in the oldest neighborhoods of the city, where lead paint is still present. X-Ray absorption spectroscopy experiments were conducted at the Stanford Synchrotron Radiation Laboratory on beam lines 7-3 and 10-2. Spectra were collected at the Pb L-III absorption edge in fluorescence mode using a 13-element or a 30-element Ge solid-state detector. This publication was made possible by grant numbers 1RO1-ES11367 and 1 S11 ES013339-01A1 from the National Institute of Environmental Health Sciences (NIEHS), NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIEHS, NIH.
Miyake, Tomohiro; Iwamoto, Takuya; Tanimura, Manabu; Okuda, Masahiro
2013-12-01
In spite of current recommended safe handling procedures, the potential for the exposure of healthcare providers to hazardous drugs exists in the workplace. A reliance on biological safety cabinets to provide total protection against the exposure to hazardous drugs is insufficient. Preventing workplace contamination is the best strategy to minimize cytotoxic drug exposure in healthcare providers. This study was conducted to compare surface contamination and personnel exposure to cyclophosphamide before and after the implementation of a closed-system drug transfer device, PhaSeal, under the influence of cleaning according to the Japanese guidelines. Personnel exposure was evaluated by collecting 24 h urine samples from 4 pharmacists. Surface contamination was assessed by the wiping test. Four of 6 wipe samples collected before PhaSeal indicated a detectable level of cyclophosphamide. About 7 months after the initiation of PhaSeal, only one of 6 wipe samples indicated a detectable level of cyclophosphamide. Although all 4 employees who provided urine samples had positive results for the urinary excretion of cyclophosphamide before PhaSeal, these levels returned to minimal levels in 2 pharmacists after PhaSeal. In combination with the biological safety cabinet and cleaning according to the Japanese guidelines, PhaSeal further reduces surface contamination and healthcare providers exposure to cyclophosphamide to almost undetectable levels.
An electro-conductive organic coating for scanning electron microscopy (déjà vu)
NASA Astrophysics Data System (ADS)
Burnett, Bryan R.
2014-09-01
An organic compound, originally marketed as an antistatic, can form an extremely thin electro-conductive coating upon drying. A scanning electron microscope (SEM) application for this compound was first explored in the late 1960s. A coating of this compound eliminates the need for carbon or gold coating in some applications. It is well suited for the viewing of fabric samples and associated gunshot residue (GSR) in the SEM and makes it possible to quickly analyze fabric bullet wipe and bore wipe GSR. Fabric samples can also be examined for GSR from intermediate-range shots to estimate muzzle-target distances. Scanning
Evaluation of Disinfection Techniques for, and Their Effects on, Rectal Thermocouple Catheters1
Maher, J. T.; Rogers, M. R.; Peterson, D. W.
1961-01-01
The antibacterial activities of an iodophor (Wescodyne G), a quaternary ammonium compound (Roccal), and an iodine tincture as agents for the cold disinfection of rectal catheters contaminated in vitro were determined. Following thorough cleaning with an alcoholic solution of soft soap, each of the three disinfectants tested showed satisfactory results (100% kill) in 5 min against the enteric test bacteria (Escherichia coli and Salmonella typhosa) as well as a test species of the genus Pseudomonas, among the bacteria most resistant to surface-active agents. An aqueous solution of Wescodyne G containing 75 ppm available iodine was used both as a wiping solution and for subsequent disinfection of rectal catheters contaminated in vivo. Total bacterial destruction was found to follow a 60-min soak preceded by the wiping procedure. Rectal catheters subjected to prolonged immersion in each of the test disinfectants were found to be essentially unaffected, retaining their initial calibrations within a permissible tolerance. Neither Roccal nor Wescodyne G solutions were found to measurably attack bare thermocouples. Alcoholic iodine 0.5% did, however, exert a deteriorating effect on bare thermocouples in a short time, as measured by change in resistance characteristics. The results of this study have led to the recommendation that Wescodyne G containing 75 ppm available iodine be used in standing operating procedures for the initial cleaning and subsequent disinfection of rectal thermocouple catheters. Images Fig. 1 PMID:13765378
Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.
Desjardins, Philippe; Hansen, Joel B; Allen, Michael
2009-11-04
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
40 CFR 761.312 - Compositing of samples.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to composite surface wipe test samples and to use the composite measurement to represent the PCB concentration of the entire surface. Composite samples consist of more than one sample gauze extracted and... arithmetic mean of the composited samples. (a) Compositing samples from surfaces to be used or reused. For...
40 CFR 761.250 - Sample site selection for pipeline section abandonment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample site selection for pipeline... Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.250 Sample site selection for pipeline section abandonment. This procedure...
40 CFR 761.250 - Sample site selection for pipeline section abandonment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sample site selection for pipeline... Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.250 Sample site selection for pipeline section abandonment. This procedure...
Galea, Karen S; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez
2014-06-01
Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs' trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods' comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Fent, Kenneth W; Alexander, Barbara; Roberts, Jennifer; Robertson, Shirley; Toennis, Christine; Sammons, Deborah; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin
2017-10-01
Firefighters' skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters' turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments. Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire. Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters' hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17-36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (< 24 micrograms per square meter [µg/m 2 ]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75 th percentile values on the neck were 152, 71.7, and 39.3 µg/m 2 , respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 µg/m 2 , respectively) than other positions (< 10.5 µg/m 2 ). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.
Wille, Sarah M R; Di Fazio, Vincent; Toennes, Stefan W; van Wel, Janelle H P; Ramaekers, Johannes G; Samyn, Nele
2015-03-01
Oral fluid (OF) is potentially useful to detect driving under the influence of drugs because of its ease of sampling. While cannabis is the most prevalent drug in Europe, sensitivity issues for Δ(9) -tetrahydrocannabinol (THC) screening and problems during OF collection are observed. The ability of a recently improved OF screening device - the DrugWipe5S(®) , to detect recent THC use in chronic cannabis smokers, was studied. Ten subjects participated in a double-blind placebo-controlled study. The subjects smoked two subsequent doses of THC; 300 µg/kg and 150 µg/kg with a pause of 75 min using a Volcano vapourizer. DrugWipe5S(®) screening and OF collection using the Quantisal™ device were performed at baseline, 5 min after each administration and 80 min after the last inhalation. Blood samples were drawn simultaneously. The screening devices (n = 80) were evaluated visually after 8 min, while the corresponding OF and serum samples were analyzed respectively with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) or gas chromatography-mass spectrometry (GC-MS). Neat OF THC concentrations ranged from 12 361 ng/g 5 min after smoking down to 34 ng/g 80 min later. Under placebo conditions, a median THC concentration of 8 ng/g OF (0-746 ng/g) and < 1 ng/ mL serum (0-7.8 ng/mL) was observed. The DrugWipe5S(®) was positive just after smoking (90%); however, sensitivity rapidly decreased within 1.5 h (50%). Sensitivity of DrugWipe5S(®) should be improved. As chronic cannabis users have high residual THC concentrations in their serum and OF, confirmation cut-offs should be set according to the aim of detecting recent drug use or establishing zero tolerance. Copyright © 2014 John Wiley & Sons, Ltd.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 38 control samples (spikes) from 18 households. Measurements were made in spiked samples of dust, food, beverages, blood, urine, and dermal wipe residue. Spiked samples we...
40 CFR 761.257 - Determining the regulatory status of sampled pipe.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COMMERCE, AND USE PROHIBITIONS Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe... disposal of a pipe segment that has been sampled, the sample results for that segment determines its PCB...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
Williams, G J; Denyer, S P; Hosein, I K; Hill, D W; Maillard, J-Y
2007-12-01
We developed a three-step protocol to quantify the efficacy of disinfectant wipes, their ability to remove and prevent microbial transfer from surfaces and their overall antimicrobial activity. Meticillin-resistant (MRSA) or -susceptible (MSSA) Staphylococcus aureus (6-7 log(10)cfu) were inoculated onto stainless steel discs with or without organic load and dried. Grapefruit extract-containing test wipes and unmedicated control wipes were used. In step 1, wipes were mechanically rotated against surfaces for 10s at 60rpm, exerting a weight of 100+/-5g. Bacterial removal was assessed by transferring the steel discs to neutraliser, resuspending and counting remaining bacteria. In step 2, bacterial transfer from wipes was assessed by eight consecutive mechanical adpression transfers to agar/neutraliser plates. Step 3 was the measurement of antimicrobial activity by direct inoculation of the wipes for 10s followed by neutralisation and enumeration. Test wipes achieved a significantly higher bacterial cell removal than control wipes on all surfaces (P<0.05). The low bactericidal activity of the wipes (<1 log(10) reduction when directly inoculated) and the subsequent survival of bacteria on the wipes, however, led to repeated microbial transfer when initially high contamination levels were present. There were no differences between MRSA and MSSA in removal, transfer or antimicrobial activity. The three-step method is a useful tool for developing future guidelines to assess the ability of wipes to disinfect surfaces.
40 CFR 761.247 - Sample site selection for pipe segment removal.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.247 Sample site selection for pipe segment removal. (a) General. (1) Select the pipe... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample site selection for pipe segment...
40 CFR 761.247 - Sample site selection for pipe segment removal.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sample site selection for pipe segment... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.247 Sample site selection for pipe segment removal. (a) General. (1) Select the pipe...
Hart, Julie F; Spear, Terry M; Ward, Tony J; Baldwin, Caitlan E; Salo, Marissa N; Elashheb, Mohamed I
2009-01-01
Amphibole asbestos (AA) has been detected on the surface of tree bark in forests neighboring an abandoned vermiculite mine near Libby, Montana. In the present study, simulations were performed to assess potential AA exposure associated with United States Department of Agriculture Forest Service (FS) occupational activities. Bark samples were collected prior, and personal breathing zone (PBZ) and Tyvek clothing wipe samples were collected during and immediately after trials that simulated FS activities. Transmission electron microscopy (TEM) analyses revealed AA bark concentrations up to 15 million structures per square centimeter (s/cm(2)). AA was detected in 25% of the PBZ TEM samples. AA was detected on wipe samples collected from all activities evaluated. This research demonstrates the potential for airborne exposure and transport of AA in the Kootenai National Forest. These findings are especially relevant to those that work in the area and to the general public who may conduct recreational activities.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANK SAMPLES
The Pesticides in Blank Samples data set contains the analytical results of measurements of up to 4 pesticides in 43 blank samples from 29 households. Measurements were made in blank samples of dust, indoor and outdoor air, food and beverages, blood, urine, and dermal wipe resid...
Clarification of Net Contents Declarations for Antimicrobial Wipe Products
EPA requirements with respect to weights on wipe product labels are described and will be applied prospectively to all wipe products. The Agency considers that these wipe products are a mixture of liquid and solid.
Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
Desjardins, Philippe; Hansen, Joel B.; Allen, Michael
2009-01-01
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 μL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay. PMID:19890248
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 15 control samples (spikes) from 11 households. Measurements were made in spiked samples of dust, food, and dermal wipe residue. Spiked samples were used to assess recover...
Bartel, Sylvia B; Tyler, Timothy G; Power, Luci A
2018-02-15
Results of a study to evaluate the effectiveness of a recently introduced closed system drug-transfer device (CSTD) in reducing surface contamination during compounding and simulated administration of antineoplastic hazardous drugs (AHDs) are reported. Wipe samples were collected from 6 predetermined surfaces in compounding and infusion areas of 13 U.S. cancer centers to establish preexisting levels of surface contamination by 2 marker AHDs (cyclophosphamide and fluorouracil). Stainless steel templates were placed over the 6 previously sampled surfaces, and the marker drugs were compounded and infused per a specific protocol using all components of the CSTD. Wipe samples were collected from the templates after completion of tasks and analyzed for both marker AHDs. Aggregated results of wipe sampling to detect preexisting contamination at the 13 study sites showed that overall, 66.7% of samples (104 of 156) had detectable levels of at least 1 marker AHD; subsequent testing after CSTD use per protocol found a sample contamination rate of 5.8% (9 of 156 samples). In the administration areas alone, the rate of preexisting contamination was 78% (61 of 78 samples); with use of the CSTD protocol, the contamination rate was 2.6%. Twenty-six participants rated the CSTD for ease of use, with 100% indicating that they were satisfied or extremely satisfied. A study involving a rigorous protocol and 13 cancer centers across the United States demonstrated that the CSTD reduced surface contamination by cyclophosphamide and fluorouracil during compounding and simulated administration. Participants reported that the CSTD was easy to use. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Yoshida, Jin; Koda, Shigeki; Nishida, Shozo; Yoshida, Toshiaki; Miyajima, Keiko; Kumagai, Shinji
2011-03-01
The aim of the present study was to evaluate the measurement of contamination by antineoplastic drugs for safer handling of such drugs by medical workers. We investigated the relationship between the contamination level of antineoplastic drugs and the conditions of their handling. Air samples and wipe samples were collected from equipment in the preparation rooms of five hospitals (hospitals A-E). These samples were subjected to measurement of the amounts of cyclophosphamide (CPA), fluorouracil (5FU), gemcitabine (GEM), and platinum-containing drugs (Pt). Twenty-four-hour urine samples were collected from the pharmacists who handled or audited, the antineoplastic drugs were analyzed for CPA and Pt. Pt was detected from air samples inside BSC in hospital B. Antineoplastic drugs were detected from wipe samples of the BSC in hospitals A, B, D, and E and of other equipment in the preparation rooms in hospitals A, B, C, and D. Cyclophosphamide and 5FU were detected from wipe samples of the air-conditioner filter in hospital A, and CPA was detected from that in hospital D. Cyclophosphamide was detected from urine samples of workers in hospitals B, D, and E. The contamination level of antineoplastic drugs was suggested to be related with the amount of drugs handled, cleaning methods of the equipment, and the skill level of the technique of maintaining negative pressure inside a vial. In order to reduce the contamination and exposure to antineoplastic drugs in the hospital work environment very close to zero, comprehensive safety precautions, including adequate mixing and cleaning methods was required in addition to BSC and closed system device.
This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.
Ruple-Czerniak, A; Bolte, D S; Burgess, B A; Morley, P S
2014-07-01
Nosocomial salmonellosis is an important problem in veterinary hospitals that treat horses and other large animals. Detection and mitigation of outbreaks and prevention of healthcare-associated infections often require detection of Salmonella enterica in the hospital environment. To compare 2 previously published methods for detecting environmental contamination with S. enterica in a large animal veterinary teaching hospital. Hospital-based comparison of environmental sampling techniques. A total of 100 pairs of environmental samples were collected from stalls used to house large animal cases (horses, cows or New World camelids) that were confirmed to be shedding S. enterica by faecal culture. Stalls were cleaned and disinfected prior to sampling, and the same areas within each stall were sampled for the paired samples. One method of detection used sterile, premoistened sponges that were cultured using thioglycolate enrichment before plating on XLT-4 agar. The other method used electrostatic wipes that were cultured using buffered peptone water, tetrathionate and Rappaport-Vassiliadis R10 broths before plating on XLT-4 agar. Salmonella enterica was recovered from 14% of samples processed using the electrostatic wipe sampling and culture procedure, whereas S. enterica was recovered from only 4% of samples processed using the sponge sampling and culture procedure. There was test agreement for 85 pairs of culture-negative samples and 3 pairs of culture-positive samples. However, the remaining 12 pairs of samples with discordant results created significant disagreement between the 2 detection methods (P<0.01). Persistence of Salmonella in the environment of veterinary hospitals can occur even with rigorous cleaning and disinfection. Use of sensitive methods for detection of environmental contamination is critical when detecting and mitigating this problem in veterinary hospitals. These results suggest that the electrostatic wipe sampling and culture method was more sensitive than the sponge sampling and culture method. © 2013 EVJ Ltd.
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROHIBITIONS Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope... determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
RELATIONSHIPS OF METALS IN FLOOR DUST AND ON THE HANDS OF TODDLERS
Toddlers are characterized by their frequent hand-to-mouth activity and exploratory behavior. This puts them at risk for exposure to environmental contaminants. Wipe samples are traditionally used to collect dust samples in homes. The assumption is that dust samples are indicativ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula
2011-05-01
Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the false negative rate (FNR). The FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method.more » A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not FNR (which left a major gap in available information). Quantifying the FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The testing was performed by SNL and is now completed. The study investigated the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and FNR. The experimental design involves 16 test runs, performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) were tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations were very low and presented challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and FNR over the full range of concentrations of interest. In each run, there were 10 test coupons of each of the three surface materials. A positive control sample was generated at the same time as each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and FNR-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the FNR for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting FNR-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in FNR and RE predictions made with the fitted equations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula
2010-12-16
Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5)more » sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.« less
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 82 blank samples from 26 households. Measurements were made in blank samples of dust, indoor and outdoor air, personal air, food, beverages, blood, urine, and dermal wipe r...
Emery, R J
1997-03-01
Institutional radiation safety programs routinely use wipe test sampling and liquid scintillation counting analysis to indicate the presence of removable radioactive contamination. Significant volumes of liquid waste can be generated by such surveillance activities, and the subsequent disposal of these materials can sometimes be difficult and costly. In settings where large numbers of negative results are regularly obtained, the limited grouping of samples for analysis based on expected value statistical techniques is possible. To demonstrate the plausibility of the approach, single wipe samples exposed to varying amounts of contamination were analyzed concurrently with nine non-contaminated samples. Although the sample grouping inevitably leads to increased quenching with liquid scintillation counting systems, the effect did not impact the ability to detect removable contamination in amounts well below recommended action levels. Opportunities to further improve this cost effective semi-quantitative screening procedure are described, including improvements in sample collection procedures, enhancing sample-counting media contact through mixing and extending elution periods, increasing sample counting times, and adjusting institutional action levels.
Efficacy of commercially available wipes for disinfection of pulse oximeter sensors.
Nandy, Poulomi; Lucas, Anne D; Gonzalez, Elizabeth A; Hitchins, Victoria M
2016-03-01
This study examined the effectiveness of commercially available disinfecting wipes and cosmetic wipes in disinfecting pulse oximeter sensors contaminated with pathogenic bacterial surrogates. Surrogates of potential biological warfare agents and bacterial pathogens associated with hospital-acquired infections (HAIs) were spotted on test surfaces, with and without an artificial test soil (sebum), allowed to dry, and then cleaned with different commercially available cleaning and disinfecting wipes or sterile gauze soaked in water, bleach (diluted 1:10), or 70% isopropanol. The percentage of microbial survival and an analytical estimation of remaining test soil on devices were determined. Wipes containing sodium hypochlorite as the active ingredient and gauze soaked in bleach (1:10) were the most effective in removing both vegetative bacteria and spores. In the presence of selective disinfectants, sebum had a protective effect on vegetative bacteria, but not on spores. The presence of sebum reduces the cleaning efficiency of some commercially available wipes for some select microbes. Various commercial wipes performed significantly better than the designated cleaning agent (70% isopropanol) in disinfecting the oximetry sensor. Cosmetic wipes were not more effective than the disinfecting wipes in removing sebum. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 52 blank samples. Measurements were made in blank samples of dust, indoor air, food, water, and dermal wipe residue. Blank samples were used to assess the potential for sa...
Six children with allergic contact dermatitis to methylisothiazolinone in wet wipes (baby wipes).
Chang, Mary Wu; Nakrani, Radhika
2014-02-01
Methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a combination preservative used in personal care and household products and is a common cause of allergic contact dermatitis (ACD). Recently, MI alone, without MCI, has been increasingly used in consumer products in attempts to minimize allergic reactions. Wet wipes are extensively tested and traditionally believed to be innocuous. MI in wet wipes ("baby wipes") has not been previously reported to cause ACD in children in the United States. Only 1 previous report of ACD in a child in Belgium has been recently reported. We report 6 children with chronic, perianal/buttock, and facial eczematous dermatitis, refractory to multiple topical and oral antibiotics and corticosteroids. All tested positive to MCI/MI on patch testing. None wore diapers. All patients had been using wet wipes containing MI (without MCI) to affected areas. Discontinuation of wipes resulted in rapid and complete resolution. This is the first report of pediatric ACD to MI in wet wipes in the United States, and the largest series to date. ACD to MI in wet wipes is frequently misdiagnosed as eczema, impetigo, or psoriasis. Wet wipes are increasingly marketed in personal care products for all ages, and MI exposure and sensitization will likely increase. Dermatitis of the perianal, buttock, facial, and hand areas with a history of wet wipe use should raise suspicion of ACD to MI and prompt appropriate patch testing. Rapid resolution occurs after the allergen exposure is eliminated. All isothiozolinones should be avoided in personal care and household products for these patients.
Ogai, K; Matsumoto, M; Aoki, M; Ota, R; Hashimoto, K; Wada, R; Kobayashi, M; Sugama, J
2017-11-01
Presently, skin-cleaning agents that claim to be removed by water or wiping alone are commercially available and have been used for the purpose of bed baths. However, there is a lack of knowledge on how water washing and wiping differently affect skin physiological functions or ceramide content. The aim of this study was to compare the effects of water washing and wiping on skin physiological functions and ceramide content. Three kinds of the cleaning agents with different removal techniques (ie, water washing and wiping) were used in this study. Skin physiological functions (ie, transepidermal water loss, skin hydration, and skin pH) and skin ceramide content were measured before and after seven consecutive days of the application of each cleaning agent. No significant differences in skin physiological functions or ceramide content were observed between water washing and wiping. Cleaning agents that claim to be removed by water washing or wiping do not affect skin physiological functions or ceramide content by either removal method. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria
2015-03-06
Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between 0.093 and 247μgg(-1). In the case of phthalates, the forbidden phthalates dibutyl phtalate (DBP) and di(2-ethylhexyl)phthalate (DEHP) were also found in thirteen samples at low levels. All the samples contained fragrance allergens in many cases at high levels (up to 2400μgg(-1)) and three musks were detected in the samples. Excluding the banned compounds, all samples complied with the concentration limits established by the European Regulation although 25% of them did not fulfill the labeling requirements for fragrance allergens. Copyright © 2015 Elsevier B.V. All rights reserved.
Bacterial vaginosis - aftercare
... takes a sample of discharge with a sterile cotton swab. The discharge is examined under a microscope ... tampons or pads. Wear loose-fitting clothing and cotton underwear. Avoid wearing pantyhose. Wipe from front to ...
Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George
2014-06-01
Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.
Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials
NASA Technical Reports Server (NTRS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials
NASA Astrophysics Data System (ADS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-09-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Warshaw, Erin M; Aschenbeck, Kelly A; Zug, Kathryn A; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Sasseville, Denis; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby; DeKoven, Joel G
Although there are several case reports of wet wipe-associated contact dermatitis, the prevalence of wipes as a source of allergic contact dermatitis in larger populations and the responsible allergens are largely unknown. The aim of the study was to determine the prevalence of wet wipes as a source of contact allergy and the most commonly associated allergens in a North American tertiary referral patch test population. Data collected from 2011 to 2014 by the North American Contact Dermatitis Group was used to conduct a retrospective cross-sectional analysis of patient demographics and patch test results associated with the triple-digit source code for "wet wipe." Of the 9037 patients patch tested during the study period, 79 (0.9%) had a positive patch test reaction to an allergen identified with a wet wipe source. The most commonly associated allergens were preservatives, including the following: methylisothiazolinone (MI) (59.0%), methylchloroisothiazolinone (MCI)/MI (35.6%), bronopol (2-bromo-2-nitropropane-1,3-diol) (27.4%), and iodopropynyl butylcarbamate (12.3%). Fragrance (combined) represented 12.3%. Anal/genital dermatitis was 15 times more likely (P < 0.0001) in those with wet wipe allergy. More than 92% of patients with wipe-associated contact allergy had their contact allergens detected by the North American Contact Dermatitis Group screening series. Wet wipes are an important source of contact allergy. Preservatives are the main allergens, especially isothiazolinones.
40 CFR 761.372 - Specific requirements for relatively clean surfaces.
Code of Federal Regulations, 2012 CFR
2012-07-01
... that each 900 cm2 (1 square foot) of the surface is always very wet for 1 minute. Wipe smooth surfaces with a solvent-soaked, disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Any surface square foot shall also be wiped for 1 minute. Wipe, mop, and/or sorb the solvent...
40 CFR 761.372 - Specific requirements for relatively clean surfaces.
Code of Federal Regulations, 2014 CFR
2014-07-01
... that each 900 cm2 (1 square foot) of the surface is always very wet for 1 minute. Wipe smooth surfaces with a solvent-soaked, disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Any surface square foot shall also be wiped for 1 minute. Wipe, mop, and/or sorb the solvent...
Allergenic Ingredients in Personal Hygiene Wet Wipes.
Aschenbeck, Kelly A; Warshaw, Erin M
Wet wipes are a significant allergen source for anogenital allergic contact dermatitis. The aim of the study was to calculate the frequency of potentially allergenic ingredients in personal hygiene wet wipes. Ingredient lists from brand name and generic personal hygiene wet wipes from 4 large retailers were compiled. In the 54 personal hygiene wet wipes evaluated, a total of 132 ingredients were identified (average of 11.9 ingredients per wipe). The most common ingredients were Aloe barbadensis (77.8%), citric acid (77.8%), fragrance (72.2%), sorbic acid derivatives (63.0%), tocopherol derivatives (63.0%), glycerin (59.3%), phenoxyethanol (55.6%), disodium cocoamphodiacetate (53.7%), disodium ethylenediaminetetraacetic acid (EDTA) (42.6%), propylene glycol (42.6%), iodopropynyl butylcarbamate (40.7%), chamomile extracts (38.9%), sodium benzoate (35.2%), bronopol (22.2%), sodium citrate (22.2%), lanolin derivatives (20.4%), parabens (20.4%), polyethylene glycol derivatives (18.5%), disodium phosphate (16.7%), dimethylol dimethyl hydantoin (DMDM) (14.8%), and cocamidopropyl propylene glycol (PG)-dimonium chloride phosphate (11.1%). Of note, methylisothiazolinone (5.6%) was uncommon; methylchloroisothiazolinone was not identified in the personal hygiene wet wipes examined. There are many potential allergens in personal hygiene wet wipes, especially fragrance and preservatives.
RAPID SPATIAL MAPPING OF CHEMICALS DISPERSED ACROSS SURFACES USING AN AUTOSAMPLER/DART/TOFMS
Rapid identification and semi-quantitation of chemicals spatially dispersed and
deposited on surfaces by accidental, deliberate, or weather-related events requires analysis of
hundreds of samples, usually obtained by sampling with wipes. Hand-held devices used on-si...
Protocol for Detection of Bacillus anthracis in Environmental Samples
This pProtocol Method describes proceduresintended for the analyses of swabs, wipes, Sponge-Sticks, vacuum socks and filters, air filters, drinking water, and decontamination waste water for Bacillus anthracis spores.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gulson, Brian, E-mail: brian.gulson@mq.edu.au; CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113; Anderson, Phil
Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floormore » wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10 µg/dL. • High precision lead isotopic ratios in blood, house dust wipes, soil, water, paint. • Associations for isotopic measures of blood and dust, blood and soil, blood and paint. • Regressions gave significance for isotopic measures of blood/dust and dust/soil.« less
... prefold diapers) a container of warm water and cotton balls (for babies with sensitive skin) or a ... ability to roll. Wiping Using the wet washcloth, cotton balls, or baby wipes, gently wipe your baby ...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
Chemicals are dispersed by numerous accidental, deliberate, or weather-related events. Often, rapid analyses are desired to identify dispersed chemicals and to delineate areas of contamination. Hundreds of wipe samples might be collected from outdoor surfaces or building interi...
An inexpensive autosampler for a DART/TOFMS provides mass spectra from analytes absorbed on 76 cotton swab, wipe samples in 7.5 min. A field sample carrier simplifies sample collection and provides swabs nearly ready for analysis to the lab. Applications of the high throughput pr...
Seenama, Chakkraphong; Tachasirinugune, Peenithi; Jintanothaitavorn, Duangporn; Kachintorn, Kanchana; Thamlikitkul, Visanu
2013-02-01
To determine the effectiveness of Virusolve+ disinfectant wipes and PAL disinfectant wipes for decontamination of inoculated bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital. Tryptic soy broths containing MRSA and XDR A. baumannii were painted onto the surfaces of patient's stainless steel bed rail, patient's fiber footboard, control panel of infusion pump machine and control panel of respirator. The contaminated surfaces were cleaned by either tap water, tap water containing detergent, Virusolve+ disinfectant wipes or PAL disinfectant wipes. The surfaces without any cleaning procedures served as the control surface. The contaminated surfaces cleaned with the aforementioned procedures and control surfaces were swabbed with cotton swabs. The swabs were streaked on agar plates to determine the presence of MRSA and XDR A. baumannii. MRSA and XDR A. baumannii were recovered from all control surfaces. All surfaces cleaned with tap water or tap water containing detergent revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with tap water containing detergent were less than those cleaned with tap water alone. All surfaces cleaned with PAL disinfectant wipes also revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with PAL disinfectant wipes were less than those cleaned with tap water containing detergent. No bacteria were recovered from all surfaces cleaned with Virusolve+ disinfectant wipes. Virusolve+ disinfectant wipes were more effective than tap water; tap water containing detergent and PAL disinfectant wipes for decontamination of bacteria inoculated on patients environmental and medical equipment surfaces at Siriraj Hospital.
Preparation of paper scintillator for detecting 3H contaminant.
Miyoshi, Hirokazu; Ikeda, Toshiji
2013-09-01
Liquid scintillator (LS)-encapsulated silica was prepared by the sol-gel method and then was added dropwise onto a wipe paper to form a paper scintillator. First, the efficiencies of wipe were determined for both the paper scintillator and the wipe paper using a liquid scintillation counter (LSC). The efficiencies of wipe using the paper scintillator and the wipe paper were 88 and 36 %, respectively. The detection efficiencies were 5.5 % for the paper scintillator, 46 % for the wipe paper using an LS and 0.08 % for the (3)H/(14)C survey meter, respectively, compared with that of a melt-on scintillator of 47 %. Second, an (3)H contaminant on the paper scintillator was successfully detected using a photomultiplier without an LSC or an (3)H/(14)C survey meter. Finally, the paper scintillator was able to detect beta rays of the (3)H contaminant easily without an LS.
Review Process for the Registration and Use Directions for Floor Wipe Towelette Products
This guidance provides Antimicrobials Division staff with guidance related to the registration requirements and use directions for presaturated/impregnated floor wipe towelette products. This document will be used for new and existing wipe registrations.
EPA collected ambient air samples in lower Manhattan for about nine months following the September 11, 2001 (9/11) World Trade Center (WTC) attacks. Measurements were made of a host of airborne contaminants including volatile organic compounds (VOCs), polycyclic aromatic hydroca...
USDA-ARS?s Scientific Manuscript database
Broilers may carry Salmonella and Campylobacter on inner and outer surfaces upon arrival at the slaughter plant and carcasses can be further contaminated during commercial processing. A sensitive, non-destructive, repeatable sampling method would be useful to test carcasses for levels of bacteria b...
USDA-ARS?s Scientific Manuscript database
Advances in nanotechnology are creating synergy with nonwoven technology in cleaning and/or disinfecting power for the next generation of wipe products. However, there is little known about the use of cotton fiber in wipes as a nanoengineering tool, which self-produces silver nanoparticles -- one of...
Hammel, Stephanie C.; Hoffman, Kate; Webster, Thomas F.; Anderson, Kim A.; Stapleton, Heather M.
2016-01-01
Organophosphate flame retardants (PFRs) are widely used as replacements for polybrominated diphenyl ethers in consumer products. With high detection in indoor environments and increasing toxicological evidence suggesting a potential for adverse health effects, there is a growing need for reliable exposure metrics to examine individual exposures to PFRs. Silicone wristbands have been used as passive air samplers for quantifying exposure in the general population and occupational exposure to polycyclic aromatic hydrocarbons. Here we investigated the utility of silicone wristbands in measuring exposure and internal dose of PFRs through measurement of urinary metabolite concentrations. Wristbands were also compared to hand wipes as metrics of exposure. Participants wore wristbands for five consecutive days and collected first morning void urine samples on three alternating days. Urine samples were pooled across the three days and analyzed for metabolites of the following PFRs: tris(1,3-dichloroisopropyl) phosphate (TDCIPP), tris(1-chloro-2-isopropyl) phosphate (TCIPP), triphenyl phosphate (TPHP), and mono-substituted isopropylated triaryl phosphate (mono-ITP). All four PFRs and their urinary metabolites were ubiquitously detected. Correlations between TDCIPP and TCIPP and their corresponding urinary metabolites were highly significant on the wristbands (rs= 0.5-0.65, p<0.001), which suggest that wristbands can serve as strong predictors of cumulative, five-day exposure and may be an improved metric compared to hand wipes. PMID:26975559
Morgan, Marsha K.
2012-01-01
Pyrethroid insecticides are frequently used to control insects in residential and agriculture settings in the United States and worldwide. As a result, children can be potentially exposed to pyrethroid residues in food and at home. This review summarizes data reported in 15 published articles from observational exposure measurement studies conducted from 1999 to present that examined children’s (5 months to 17 years of age) exposures to pyrethroids in media including floor wipes, floor dust, food, air, and/or urine collected at homes in the United States. At least seven different pyrethroids were detected in wipe, dust, solid food, and indoor air samples. Permethrin was the most frequently detected (>50%) pyrethroid in these media, followed by cypermethrin (wipes, dust, and food). 3-phenoxybenzoic acid (3-PBA), a urinary metabolite of several pyrethroids, was the most frequently (≥67%) detected pyrethroid biomarker. Results across studies indicate that these children were likely exposed to several pyrethroids, but primarily to permethrin and cypermethrin, from several sources including food, dust, and/or on surfaces at residences. Dietary ingestion followed by nondietary ingestion were the dominate exposure routes for these children, except in homes with frequent pesticide applications (dermal followed by dietary ingestion). Urinary 3-PBA concentration data confirm that the majority of the children sampled were exposed to one or more pyrethroids. PMID:23066409
Exposure to organophosphate flame retardants of hotel room attendants in Wuhan City, China.
Tao, Yun; Shang, Yinzhu; Li, Jing; Feng, Jingwen; He, Zhenyu; Covaci, Adrian; Wang, Peng; Luo, Jing; Mao, Xiang; Shi, Bin; Hu, Liqin; Luo, Dan; Mei, Surong
2018-05-01
Indoor environments provide sources of exposure to organophosphate flame retardants (PFRs), which are artificially synthesized fire-protecting agents used as additives in interior products. As public spaces, hotels are required to meet stricter fire-precaution criteria. As such, room attendants may be exposed to higher levels of PFRs. Our goal was to characterize the exposure of hotel room attendants to PFRs by measuring metabolites in their urine and the corresponding parent PFRs in dust and hand-wipes collected from 27 hotels located in Wuhan City, China. The exposure of the attendants was found to be omnipresent: urinary metabolites of PFRs, such as DPHP (diphenyl phosphate), BDCIPP (bis(1,3-dichloro-2-propyl) phosphate), and DoCP (di-o-cresyl phosphate) & DpCP (di-p-cresyl phosphate) were detected with high frequency (87%, 79% and 87%, respectively). We observed that metabolites in post-shift urine were consistently present at higher levels than those in the first morning voids (p < 0.05 for BDCIPP and DPHP). Regarding external exposure, 10 PFRs were determined in both dust samples and hand-wipes, with TCIPP (tris(2-chloroisopropyl) phosphate) being the most abundant compound in both matrices. The levels of PFRs in hand-wipes and dust samples were not correlated. PFRs in dust and their corresponding urinary metabolites were not significantly correlated, while a moderate significant correlation of TDCIPP (tris(1,3-dichloro-2-propyl) phosphate) in hand-wipes and its urinary metabolite, BDCIPP, was observed in both morning void samples (p = 0.01) and post-shift urine (p = 0.002). Moreover, we found that participants from high-rise buildings (defined as > 7 stories) had significantly higher BDCIPP and DPHP concentrations than those from low-rise buildings. A possible reason is that high-rise buildings may use high-grade fireproof building materials to meet stricter fire restrictions. Overall, these results indicate that PFRs exposure in hotels is a contributor to the personal exposure of hotel room attendants. Copyright © 2018 Elsevier Ltd. All rights reserved.
Comparison of Wipe Materials and Wetting Agents for Pesticide Residue Collection from Hard Surfaces
Different wipe materials and wetting agents have been used to collect pesticide residues from surfaces, but little is known about their comparability. To inform the selection of a wipe for the National Children's Study, the analytical feasibility, collection efficiency, and preci...
Quat co-formulations optimized for use with cotton nonwoven disposable wipes
USDA-ARS?s Scientific Manuscript database
Quaternary ammonium compounds, commonly referred to as quats, are cationic surfactants widely used as the active biocidal ingredient for disposable disinfecting wipes. The cationic nature of quats results in a strong ionic interaction and adsorption onto wipes materials that have an anionic surface...
As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues.
One...
2010-05-01
absorption. Thermogravimetric Analysis (TGA) was employed to measure absorption of HD and GD into the nylon fabric. TGA is an analytical tool useful in...Chromatography Analysis 26 4.4.5.1 Mass Removed by Wiper at Room Temperature 26 4.4.6 Chemical Agent Mass Removed by Wiper at Elevated and Reduced...Temperature Tests 71 5.9 Vapor Analysis of Spent Wipe 78 5.10 Wiping Efficacy and Complex Geometries 82 5.11 Spray and Wipe Tests 84 5.12 Effect of
Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y
2015-12-01
The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.
Evaluation of a Disinfectant Wipe Intervention on Fomite-to-Finger Microbial Transfer
Lopez, Gerardo U.; Kitajima, Masaaki; Havas, Aaron; Gerba, Charles P.
2014-01-01
Inanimate surfaces, or fomites, can serve as routes of transmission of enteric and respiratory pathogens. No previous studies have evaluated the impact of surface disinfection on the level of pathogen transfer from fomites to fingers. Thus, the present study investigated the change in microbial transfer from contaminated fomites to fingers following disinfecting wipe use. Escherichia coli (108 to 109 CFU/ml), Staphylococcus aureus (109 CFU/ml), Bacillus thuringiensis spores (107 to 108 CFU/ml), and poliovirus 1 (108 PFU/ml) were seeded on ceramic tile, laminate, and granite in 10-μl drops and allowed to dry for 30 min at a relative humidity of 15 to 32%. The seeded fomites were treated with a disinfectant wipe and allowed to dry for an additional 10 min. Fomite-to-finger transfer trials were conducted to measure concentrations of transferred microorganisms on the fingers after the disinfectant wipe intervention. The mean log10 reduction of the test microorganisms on fomites by the disinfectant wipe treatment varied from 1.9 to 5.0, depending on the microorganism and the fomite. Microbial transfer from disinfectant-wipe-treated fomites was lower (up to <0.1% on average) than from nontreated surfaces (up to 36.3% on average, reported in our previous study) for all types of microorganisms and fomites. This is the first study quantifying microbial transfer from contaminated fomites to fingers after the use of disinfectant wipe intervention. The data generated in the present study can be used in quantitative microbial risk assessment models to predict the effect of disinfectant wipes in reducing microbial exposure. PMID:24610856
Wipe-rinse technique for quantitating microbial contamination on large surfaces.
Kirschner, L E; Puleo, J R
1979-01-01
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2). PMID:394682
Wipe-rinse technique for quantitating microbial contamination on large surfaces
NASA Technical Reports Server (NTRS)
Kirschner, L. E.; Puleo, J. R.
1979-01-01
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-31
... Waste Landfill NODA Notice of Data Availability NPDES National Pollutant Discharge Elimination System...-contaminated wipe or from the container holding the wipes. In addition, the exclusions are not applicable to... containers. The containers must be able to contain free liquids, should free liquids occur, and the...
Wiping Metal Transfer in Friction Stir Welding
NASA Technical Reports Server (NTRS)
Nunes, Arthur C., Jr.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
Much evidence suggests that as the friction stir pin-tool moves along a weld seam the displacement of metal takes place by a wiping action at the surface of a plug of metal that rotates with the tool. The wiping model is explained and some consequences for the friction stir welding process are drawn.
2008 Homeland Security S and T Stakeholders Conference West volume 2 Monday
2008-01-16
per collection and pressure to be applied, etc. . - Enviromental effects; dry vs. wet surface (vs. type of sample swipe), clean vs. dirty surfaces...selection of collection via low volume or high volume sampling, distance to suspect item critical, etc. - Enviromental effects; temperature (range of...selection of material, collection via hand wiping or sampling wand, area per collection and pressure to be applied, etc. . - Enviromental effects; dry
Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D
2016-08-01
Chromium is an important skin sensitizer. Exposure to it has been regulated in cement, and recently in leather. Studies on the deposition of chromium ions on the skin as a result of handling different chromium-containing materials are sparse, but could improve the risk assessment of contact sensitization and allergic contact dermatitis caused by chromium. To determine whether the handling of chromium-containing samples of leather and metal results in the deposition of chromium onto the skin. Five healthy volunteers participated. For 30 min, they handled samples of leather and metal known to contain and release chromium. Skin deposition of chromium was assessed with the acid wipe sampling technique. Acid wipe sampling of the participants' fingers showed chromium deposition on the skin in all participants who had been exposed to leather (range 0.01-0.20 µg/cm(2) ) and in 3 of 5 participants after they had manually handled metal discs (range 0.02-0.04 µg/cm(2) ). We found that samples of leather and metal had the ability to deposit chromium on the skin at significant levels, in spite of a short duration of exposure. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Study on the wiping gas jet in continuous galvanizing line
NASA Astrophysics Data System (ADS)
Kweon, Yong-Hun; Kim, Heuy-Dong
2011-09-01
In the continuous hot-dip galvanizing process, the gas-jet wiping is used to control the coating thickness of moving steel strip. The high speed gas-jet discharged from the nozzle slot impinges on the strip, and at this moment, wipes the liquid coating layer dragged by a moving strip. The coating thickness is generally influenced on the flow characteristics of wiping gas-jet such as the impinging pressure distribution, pressure gradient and shear stress distribution on the surface of strip. The flow characteristics of wiping gas-jet mentioned above depends upon considerably both the process operating conditions such as the nozzle pressure, nozzle-to-strip distance and line speed, and the geometry of gas-jet wiping apparatus such as the height of nozzle slot. In the present study, the effect of the geometry of nozzle on the coating thickness is investigated with the help of a computational fluid dynamics method. The height of nozzle slot is varied in the range of 0.6mm to 1.7mm. A finite volume method (FVM) is employed to solve two-dimensional, steady, compressible Navier-Stokes equations. Based upon the results obtained, the effect of the height of nozzle slot in the gas-jet wiping process is discussed in detail. The computational results show that for a given standoff distance between the nozzle to the strip, the effective height of nozzle slot exists in achieving thinner coating thickness.
The effectiveness of a novel infant tooth wipe in high caries-risk babies 8 to15 months old.
Galganny-Almeida, Anna; Queiroz, Mellissa C; Leite, Alvaro Jorge M
2007-01-01
The purpose of this study was to assess baby and parental satisfaction and plaque-removal efficacy of a novel infant tooth wipe (Spiffies) in high caries-risk babies. Thirty-five healthy and caries-free infants were selected. Babies had never had their teeth cleaned and no primary molars were yet present. Subjects were identified with the risk factor of nightly feeding behaviors. Pre- and postcleaning oral hygiene plaque measurements were recorded and then analyzed by a blinded examiner. A manual toothbrush (Ultra Kids) was used as the control method. Infants' caregivers used their randomly assigned cleaning method without instruction. Babies returned to the clinic after a 48- to 72-hour washout period, and the procedures were repeated before and after use of the alternate method. Parental satisfaction and baby-perceived acceptance were evaluated by a questionnaire and were analyzed at the time of the visit and at bedtime. Both the infant tooth wipe and conventional brushing significantly reduced plaque levels (P < .001). Parents were more satisfied with the wipes when compared to toothbrushing, particularly after nightly feeding habits (P < .001). Similarly, infant's acceptance was higher with the wipes at daytime and significantly higher at night-time (P = .002). The Novel novel Infant infant Tooth tooth Wipe wipe provides an effective method of plaque removal before the eruption of primary molars.
Facilities Management Guide for Asbestos and Lead
2004-11-01
equipment such as HEPA filtered power tools, portable welding exhaust systems, and paint removal equipment when work disturbs lead. Do not dry sweep ...sampling and analysis of [______] paint bulk and wipe samples by atomic absorption spectrophotometry (AA) or anodic stripping voltametry (ASV...analysis. e. All bulk (destructive) collected for lead shall be analyzed by atomic absorption spectrophotometry (AA) or anodic stripping voltametry
Forbes, Thomas P; Staymates, Matthew; Sisco, Edward
2017-08-07
Wipe collected analytes were thermally desorbed using broad spectrum near infrared heating for mass spectrometric detection. Employing a twin tube filament-based infrared emitter, rapid and efficiently powered thermal desorption and detection of nanogram levels of explosives and narcotics was demonstrated. The infrared thermal desorption (IRTD) platform developed here used multi-mode heating (direct radiation and secondary conduction from substrate and subsequent convection from air) and a temperature ramp to efficiently desorb analytes with vapor pressures across eight orders of magnitude. The wipe substrate experienced heating rates up to (85 ± 2) °C s -1 with a time constant of (3.9 ± 0.2) s for 100% power emission. The detection of trace analytes was also demonstrated from complex mixtures, including plastic-bonded explosives and exogenous narcotics, explosives, and metabolites from collected artificial latent fingerprints. Manipulation of the emission power and duration directly controlled the heating rate and maximum temperature, enabling differential thermal desorption and a level of upstream separation for enhanced specificity. Transitioning from 100% power and 5 s emission duration to 25% power and 30 s emission enabled an order of magnitude increase in the temporal separation (single seconds to tens of seconds) of the desorption of volatile and semi-volatile species within a collected fingerprint. This mode of operation reduced local gas-phase concentrations, reducing matrix effects experienced with high concentration mixtures. IRTD provides a unique platform for the desorption of trace analytes from wipe collections, an area of importance to the security sector, transportation agencies, and customs and border protection.
Macroscopic analysis of gas-jet wiping: Numerical simulation and experimental approach
NASA Astrophysics Data System (ADS)
Lacanette, Delphine; Gosset, Anne; Vincent, Stéphane; Buchlin, Jean-Marie; Arquis, Éric
2006-04-01
Coating techniques are frequently used in industrial processes such as paper manufacturing, wire sleeving, and in the iron and steel industry. Depending on the application considered, the thickness of the resulting substrate is controlled by mechanical (scraper), electromagnetic (if the entrained fluid is appropriated), or hydrodynamic (gas-jet wiping) operations. This paper deals with the latter process, referred to as gas-jet wiping, in which a turbulent slot jet is used to wipe the coating film dragged by a moving substrate. This mechanism relies on the gas-jet-liquid film interaction taking place on the moving surface. The aim of this study is to compare the results obtained by a lubrication one-dimensional model, numerical volume of fluid-large eddy simulation (VOF-LES) modeling and an experimental approach. The investigation emphasizes the effect of the controlling wiping parameters, i.e., the pressure gradient and shear stress distributions induced by the jet, on the shape of the liquid film. Those profiles obtained experimentally and numerically for a jet impinging on a dry fixed surface are compared. The effect of the substrate motion and the presence of the dragged liquid film on these actuators are analyzed through numerical simulations. Good agreement is found between the film thickness profile in the wiping zone obtained from the VOF-LES simulations and with the analytical model, provided that a good model for the wiping actuators is used. The effect of the gas-jet nozzle to substrate standoff distance on the final coating thickness is analyzed; the experimental and predicted values are compared for a wide set of conditions. Finally, the occurrence of the splashing phenomenon, which is characterized by the ejection of droplets from the runback film flow at jet impingement, thus limiting the wiping process, is investigated through experiments and numerical simulations.
Working principle of an electromagnetic wiping system
NASA Astrophysics Data System (ADS)
Ernst, R.; Fautrelle, Y.; Bianchi, A.-M.; Iliescu, M.
2009-03-01
In galvanizing lines, the gas knife wiping device works well for controlling the zinc coating thickness up to 2 to 3 m/s strip velocities. But for higher velocities, a strong liquid zinc splash risk forbids the gas pressure increase, which would be necessary to keep the same thickness control efficiency of the knives. That is why a complementary electromagnetic wiping system, whose purpose is to pre-wipe the liquid zinc before the gas knives take over, is presented here. After mentioning different kinds of AC and DC possible electromagnetic solutions, a DC field electromagnetic brake (EMB) system based on the use of permanent magnets is selected for a future experimental implementation. In order to better understand the electromagnetic and fluid mechanics phenomena, an analytical model and then different numerical models are presented here. These models show an interesting wiping effect on the liquid zinc, which seems promising for a future experimental pilot design. Figs 8, Refs 9.
American Healthy Homes Survey: A National Study of Residential Pesticides Measured from Floor Wipes.
The U.S. Department of Housing and Urban Development in collaboration with the United States Environmental Protection Agency conducted a survey measuring lead, allergens, and insecticides in a randomly selected nationally representative sample of resodential homes. Multistage sa...
Stone, Kahler W.; Kirsch, Katie R.; Camargo, Krisa; Wade, Terry L.; McDonald, Thomas J.
2018-01-01
Introduction Polycyclic aromatic hydrocarbons (PAHs) are complex environmental toxicants. Exposure to them has been linked to adverse health outcomes including cancer, as well as diseases of the skin, liver, and immune system. Based on an ongoing community engagement partnership with stakeholder groups and residents, we conducted a small longitudinal study to assess domestic exposure to PAHs among residents of Manchester, an environmental justice neighborhood located in the East End of Houston, TX. Methods In December, 2016, we used fiber wipes to collect samples of household dust from 25 homes in Manchester. Following Hurricane Harvey, in September 2017, we revisited 24 of the 25 homes to collect soil samples from the front yards of the same homes. Wipes and soil were analyzed for the presence of PAHs using gas chromatography–mass spectrometry (GC-MS) methods. Principal component analysis plots, heatmaps, and PAH ratios were used to compare pre- and post-Hurricane Harvey samples. Results While direct comparison is not possible, we present three methods for comparing PAHs found in pre-hurricane fiber wipes and post-hurricane soil samples. The methods demonstrate that the PAHs found before and after Hurricane Harvey are likely from similar sources and that those sources are most likely to be associated with combustion. We also found evidence of redistribution of PAHs due to extreme flooding associated with Hurricane Harvey. Discussion Residents of the Manchester neighborhood of Houston, TX, are exposed to a range of PAHs in household dust and outdoor soil. While it was not possible to compare directly, we were able to use several methods to assess detected concentrations, changes in site-specific PAH allocations, and PAH origination. Additional research is needed to identify specific sources of domestic PAH exposure in these communities and continued work involving community members and policy makers should aim to develop interventions to reduce domestic exposure to and prevent negative health outcomes from PAHs. PMID:29420658
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horney, Jennifer A.; Casillas, Gaston A.; Baker, Erin
Introduction: Polycyclic aromatic hydrocarbons (PAHs) are complex environmental toxicants; exposure to them has been linked to adverse health outcomes including cancer, as well as diseases of the skin, liver, and immune system. Based on an ongoing community engagement partnership with stakeholder groups and residents, we conducted a small longitudinal study to assess domestic exposure to PAHs among residents of Manchester, an environmental justice neighborhood located in the East End of Houston, TX. Methods: In December, 2016, we used fiber wipes to collect samples of household dust from 25 homes in Manchester. Following Hurricane Harvey, in September 2017, we revisited 24more » of the 25 homes to collect soil samples from the front yards of the same homes. Wipes and soil were analyzed for the presence of PAHs using gas chromatography–mass spectrometry (GC-MS) methods. Principle component analysis plots, heatmaps, and PAH ratios were used to compare pre- and post-Hurricane Harvey samples. Results: While direct comparison is difficult, we present three methods for comparing PAHs found in pre-hurricane fiber wipes and post-hurricane soil samples. The methods demonstrate that the PAHs found before and after Hurricane Harvey are likely from similar sources and that those sources are most likely to be associated with combustion. We also found evidence of redistribution of PAHs due to extreme flooding associated with Hurricane Harvey. Discussion: Residents of the Manchester neighborhood of Houston, TX, are exposed to a range of PAHs in household dust and outdoor soil. While difficult to compare directly, we were able to use several methods to assess detected concentrations, changes in site-specific PAH allocations, and PAH origination. Additional research is needed to identify specific sources of domestic PAH exposure in these communities and continued work involving community members and policy makers should aim to develop interventions to reduce domestic exposure to and prevent negative health outcomes from PAHs.« less
Potential exposures associated with indoor marijuana growing operations.
Martyny, John W; Serrano, Kate A; Schaeffer, Joshua W; Van Dyke, Mike V
2013-01-01
We entered a total of 30 indoor marijuana grow operations (IMGO) with law enforcement investigators in order to determine potential exposures to first responders. Samples for airborne fungal spores, volatile organic compounds, carbon dioxide, carbon monoxide, and delta-9-tetrahydrocannabinol (THC) were obtained as well as the identification of chemicals utilized in the IMGO. The chemicals utilized within the IMGOs were primarily pesticides and fertilizers with none showing high toxicity. Although several of the IMGOs had CO2 enrichment processes involving combustion, CO levels were not elevated. THC levels were identified on surfaces within the IMGOs and on the hands of the investigators. Surface levels ranged from <0.1 μg /100 cm(2) to 2000 μg /100 cm(2) with a geometric mean of 0.37 μg /100 cm(2). THC levels on the hands of officers ranged from <0.10 μg /wipe to 2900 μg /wipe with a geometric mean of 15 μg /wipe. These levels were not considered to be elevated to the point of causing a toxic exposure to responders. A total of 407 fungal spore samples were taken using both slit impactor plates and 400-hole impactors. Both methods identified elevated fungal spore levels, especially during the removal of plants from some of the IMGOs. After plant removal, spore counts increased to levels above 50,000 spores/m(3) with one sample over 500,000 spores/m(3). In addition, we found that there was a shift in species between indoor and outdoor samples with Cladosporium sp. the predominant outdoor species and Penicillium sp. the predominant indoor species. We concluded that the potential increase in fungal spore concentrations associated with the investigation and especially removal of the marijuana plants could potentially expose responders to levels of exposure consistent with those associated with mold remediation processes and that respiratory protection is advisable.
Horney, Jennifer A; Casillas, Gaston A; Baker, Erin; Stone, Kahler W; Kirsch, Katie R; Camargo, Krisa; Wade, Terry L; McDonald, Thomas J
2018-01-01
Polycyclic aromatic hydrocarbons (PAHs) are complex environmental toxicants. Exposure to them has been linked to adverse health outcomes including cancer, as well as diseases of the skin, liver, and immune system. Based on an ongoing community engagement partnership with stakeholder groups and residents, we conducted a small longitudinal study to assess domestic exposure to PAHs among residents of Manchester, an environmental justice neighborhood located in the East End of Houston, TX. In December, 2016, we used fiber wipes to collect samples of household dust from 25 homes in Manchester. Following Hurricane Harvey, in September 2017, we revisited 24 of the 25 homes to collect soil samples from the front yards of the same homes. Wipes and soil were analyzed for the presence of PAHs using gas chromatography-mass spectrometry (GC-MS) methods. Principal component analysis plots, heatmaps, and PAH ratios were used to compare pre- and post-Hurricane Harvey samples. While direct comparison is not possible, we present three methods for comparing PAHs found in pre-hurricane fiber wipes and post-hurricane soil samples. The methods demonstrate that the PAHs found before and after Hurricane Harvey are likely from similar sources and that those sources are most likely to be associated with combustion. We also found evidence of redistribution of PAHs due to extreme flooding associated with Hurricane Harvey. Residents of the Manchester neighborhood of Houston, TX, are exposed to a range of PAHs in household dust and outdoor soil. While it was not possible to compare directly, we were able to use several methods to assess detected concentrations, changes in site-specific PAH allocations, and PAH origination. Additional research is needed to identify specific sources of domestic PAH exposure in these communities and continued work involving community members and policy makers should aim to develop interventions to reduce domestic exposure to and prevent negative health outcomes from PAHs.
American Healthy Homes Survey: A National Study of Residential Phthalates Measured from Floor Wipes
The United States Environmental Protection Agency (U.S. EPA), in collaboration with the U.S. Department of Housing and Urban Development (HUD), conducted a survey measuring phthalates in randomly selected residential homes throughout the U.S. Multistage sampling with clustering w...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2011 CFR
2011-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. ...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2010 CFR
2010-01-01
... training; (2) On-the-job training; (3) Annual safety reviews provided by the licensee; (4) Means the... annual inspections of the job performance of each logging supervisor to ensure that the Commission's... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. ...
Methamphetamine (meth) residues from meth syntheses or habitual meth smoking pose human health hazards. State health departments require remediation of meth labs before properties are sold. NIOSH methods for meth analysis require wipe sampling, extraction, cleanup, solvent excha...
Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
Wu, Xiangmei May; Bennett, Deborah H; Moran, Rebecca E; Sjödin, Andreas; Jones, Richard S; Tancredi, Daniel J; Tulve, Nicolle S; Clifton, Matthew Scott; Colón, Maribel; Weathers, Walter; Hertz-Picciotto, Irva
2015-03-14
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in many household items. Given concerns over their potential adverse health effects, we identified predictors and evaluated temporal changes of PBDE serum concentrations. PBDE serum concentrations were measured in young children (2-8 years old; N = 67), parents of young children (<55 years old; N = 90), and older adults (≥55 years old; N = 59) in California, with concurrent floor wipe samples collected in participants' homes in 2008-2009. We also measured serum concentrations one year later in a subset of children (N = 19) and parents (N = 42). PBDE serum concentrations in children were significantly higher than in adults. Floor wipe concentration is a significant predictor of serum BDE-47, 99, 100 and 154. Positive associations were observed between the intake frequency of canned meat and serum concentrations of BDE-47, 99 and 154, between canned meat entrees and BDE-154 and 209, as well as between tuna and white fish and BDE-153. The model with the floor wipe concentration and food intake frequencies explained up to 40% of the mean square prediction error of some congeners. Lower home values and renting (vs. owning) a home were associated with higher serum concentrations of BDE-47, 99 and 100. Serum concentrations measured one year apart were strongly correlated as expected (r = 0.70-0.97) with a slight decreasing trend. Floor wipe concentration, food intake frequency, and housing characteristics can explain 12-40% of the prediction error of PBDE serum concentrations. Decreasing temporal trends should be considered when characterizing long-term exposure.
Landin, Wendell E; Mun, Greg C; Nims, Raymond W; Harbell, John W
2007-09-01
The cytosensor microphysiometer (mu phi) was investigated as a rapid, relatively inexpensive test to predict performance of skin cleansing wipes on the human 21-day cumulative irritation patch test (21CIPT). It indirectly measures metabolic rate changes in L929 cells as a function of test article dose, by measuring the acidification rate in a low-buffer medium. The dose producing a 50% reduction in metabolic rate (MRD50), relative to the baseline rate, is used as a measure of toxicity. The acute toxicity of the mu phi assay can be compared to the chronic toxicity of the 21CIPT, which is based largely on the exposure of test agents to the epidermal cells, resulting in damage and penetration of the stratum corneum leading to cell toxicity. Two series of surfactant-based cleansing wipe products were tested via the mu phi assay and 21CIPT. The first series, consisting of 20 products, was used to determine a prediction model. The second series of 38 products consisted of routine product development formulas or marketed products. Comparing the results from both tests, samples with an MRD50 greater than 50 mg/ml provided a 21CIPT score consistent with a product that performs satisfactorily in the market. When the MRD50 was greater than 78 mg/ml, the 21CIPT score was usually zero. The mu phi may be more sensitive than the 21CIPT for ranking minimally irritating materials. The mu phi assay is useful as a screen for predicting the performance of a wet wipes formula on the 21CIPT, and concurrently reduces the use of animals for safety testing in a product development program for cleansing wipes.
Assessment of human exposure to polychlorinated dibenzofurans and dioxins.
Rappe, C; Nygren, M; Marklund, S; Keller, L O; Bergqvist, P A; Hansson, M
1985-01-01
Fires, explosions and other accidents in polychlorinated biphenyl (PCB)-filled equipment can result in possible exposure of firemen, cleaning personnel and regular workers. Inhalation, dermal exposure and ingestion are the possible routes of exposure. An indirect assessment of the exposure can be made by analyses of wipes, air and water samples and clothes. A direct assessment of exposure can be made by analyses of blood samples, adipose and other tissue samples, feces and bile. PMID:4029099
Muramatsu, Keita; Matsuo, Koichiro; Kawai, Yusuke; Yamamoto, Tsukasa; Hara, Yoshitaka; Shimomura, Yasuyo; Yamashita, Chizuru; Nishida, Osamu
2018-06-26
Endotracheal intubation of critically ill patients increases the risk of aspiration pneumonia, which can be reduced by regular oral care. However, the rinsing of the residual oral contaminants after mechanical cleaning carries the risk of aspirating the residue during the intubation period. Removing the contaminants by wiping with mouth wipes could be an alternative to rinsing with water because of no additional fluid. This study tested: (i) the amount of oral bacteria during endotracheal intubation and after extubation; and (ii) the changes in the bacterial count during oral care procedures. Thirty-five mechanically ventilated patients in the intensive care unit were enrolled. The amount of bacteria on the dorsal tongue surface was counted before and following oral care and then after the elimination of contaminants either by rinsing with water and suctioning or by wiping with mouth wipes. The oral bacterial amount was compared statistically between the intubation and extubation status and among set time points during the oral care procedure. The oral bacterial count was significantly decreased after extubation. During the oral care procedure, the oral bacterial amount was significantly lower after eliminating the contaminants either by rinsing or wiping, with no remarkable difference between the elimination techniques. The findings suggest that the oral bacterial amount is elevated during endotracheal intubation, which could increase the risk of aspiration pneumonia. The significant reduction in the bacterial count by wiping indicates that it might be a suitable alternative to rinsing for mechanically ventilated patients. © 2018 Japan Academy of Nursing Science.
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, Paul J; Freeman, Natalie C G; Millette, James R
2002-01-01
In this review, we examine house dust and residential soil and their use for identifying sources and the quantifying levels of toxicants for the estimation of exposure. We answer critical questions that focus on the selection of samples or sampling strategies for collection and discuss areas of uncertainty and gaps in knowledge. We discuss the evolution of dust sampling with a special emphasis on work conducted after the publication of the 1992 review by McArthur [Appl Occup Environ Hyg 7(9):599-606 (1992)]. The approaches to sampling dust examined include surface wipe sampling, vacuum sampling, and other sampling approaches, including attic sampling. The metrics of presentation of results for toxicants in dust surface loading (micrograms per square centimeter) or surface concentration (micrograms per gram) are discussed. We evaluate these metrics in terms of how the information can be used in source characterization and in exposure characterization. We discuss the types of companion information on source use and household or personal activity patterns required to assess the significance of the dust exposure. The status and needs for wipe samplers, surface samplers, and vacuum samplers are summarized with some discussion on the strengths and weaknesses of each type of sampler. We also discuss needs for research and development and the current status of standardization. Case studies are provided to illustrate the use of house dust and residential soil in source characterization, forensic analyses, or human exposure assessment. PMID:12361921
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, Paul J; Freeman, Natalie C G; Millette, James R
2002-10-01
In this review, we examine house dust and residential soil and their use for identifying sources and the quantifying levels of toxicants for the estimation of exposure. We answer critical questions that focus on the selection of samples or sampling strategies for collection and discuss areas of uncertainty and gaps in knowledge. We discuss the evolution of dust sampling with a special emphasis on work conducted after the publication of the 1992 review by McArthur [Appl Occup Environ Hyg 7(9):599-606 (1992)]. The approaches to sampling dust examined include surface wipe sampling, vacuum sampling, and other sampling approaches, including attic sampling. The metrics of presentation of results for toxicants in dust surface loading (micrograms per square centimeter) or surface concentration (micrograms per gram) are discussed. We evaluate these metrics in terms of how the information can be used in source characterization and in exposure characterization. We discuss the types of companion information on source use and household or personal activity patterns required to assess the significance of the dust exposure. The status and needs for wipe samplers, surface samplers, and vacuum samplers are summarized with some discussion on the strengths and weaknesses of each type of sampler. We also discuss needs for research and development and the current status of standardization. Case studies are provided to illustrate the use of house dust and residential soil in source characterization, forensic analyses, or human exposure assessment.
Saleem, S; Rouse, DJ; McClure, EM; Reza, T; Yahya, Y; Memon, IA; Zaidi, Anita; Khan, NH; Memon, G; Soomro, N; Pasha, O; Wright, LL; Moore, J; Goldenberg, RL
2013-01-01
Background Sepsis is a leading cause of perinatal death in developing countries. Vaginal organisms acquired during labor play a significant role. Prior studies suggest that chlorhexidine wiping of the maternal vagina during labor and of the neonate may reduce peripartum infections. Methods We performed a placebo-controlled, randomized trial of chlorhexidine vaginal and neonatal wipes to reduce neonatal sepsis and mortality in three hospitals in Pakistan. The primary study outcome was a composite of neonatal sepsis or 7-day perinatal mortality. Findings From 2005 to 2008, 5,008 laboring women and their neonates were randomized to receive either chlorhexidine wipes (n = 2,505) or wipes with a saline placebo (n = 2,503). The primary outcome was similar in the chlorhexidine and control groups, (3.1% vs. 3.4%; RR 0.91, 95% CI 0.67, 1.24), as was the composite rate of neonatal sepsis or 28-day perinatal mortality, (3.8% vs. 3.9%, RR 0.96, 95% CI 0.73, 1.27). At day 7, the chlorhexidine group had a lower rate of neonatal skin infection. (3.3 vs. 8.2%, p<0.0001) With the exception of less frequent 7-day hospitalization in the chlorhexidine group, there were no significant differences in maternal outcomes between the groups. Interpretation This trial provides evidence that the use of maternal chlorhexidine vaginal wipes during labor and neonatal chlorhexidine wipes does not reduce maternal and perinatal mortality or neonatal sepsis. The finding of reduced superficial skin infections on day 7 without change in sepsis or mortality suggests that this difference, although statistically significant, may not be of major importance. Trial Registration: Clinicaltrials.gov: NCT00121394 PMID:20502294
A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context
Gentili, Stefano; Tittarelli, Roberta; Mannocchi, Giulio
2016-01-01
The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates) detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars) of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1%) positive to one or more drugs of abuse, whereas 75 samples (90.4%) tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50%) was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp.) for cannabis, underlying the limitation of the device for this latter drug class. PMID:27610266
EPA conducted a study to evaluate the effect of coatings on dislodgeable arsenic, chromium, and copper residues on the surfaces of chromated copper arsenate (CAA) treated wood. Dislodgeable CCA, determined by wipe sampling the wood surfaces, was the primary evaluation criterion f...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
Tebbutt, G. M.
1991-01-01
The relationship between visual inspections carried out by environmental health officers and microbiological examination was studied in 89 restaurants. Using 30 variables a standardized inspection procedure was developed and each of the premises was assessed in six main areas-structure and design, cleaning and cleanliness, personal hygiene, risk of contamination, temperature control, and training and knowledge about food hygiene. Selected foods and specimens from hands, surfaces, and wiping cloths were examined. There were significant associations between all six areas of the inspections. The structure and design were significantly related to the combined score from all the other areas (P less than 0.001). There were no highly significant associations between microbiological examination and visual assessments. The microbial contamination of wiping cloths, however, was related to the cleaning and cleanliness (P = 0.005). Microbial sampling provided additional information to inspections and was a valuable aid. Further development of this risk-assessment approach could provide an effective system for monitoring potential health risks in high-risk food premises. PMID:1936161
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
Adé, Apolline; Chauchat, Laure; Frève, Johann-François Ouellette; Gagné, Sébastien; Caron, Nicolas; Bussières, Jean-François
2017-01-01
Background Several studies have compared cleaning procedures for decontaminating surfaces exposed to antineoplastic drugs. All of the cleaning products tested were successful in reducing most of the antineoplastic drug quantities spilled on surfaces, but none of them completely removed residual traces. Objective To assess the efficacy of various cleaning solutions for decontaminating a biological safety cabinet workbench exposed to a defined amount of cyclophosphamide. Methods In this pilot study, specific areas of 2 biological safety cabinets (class II, type B2) were deliberately contaminated with a defined quantity of cyclophosphamide (10 μg or 107 pg). Three cleaning solutions were tested: quaternary ammonium, sodium hypochlorite 0.02%, and sodium hypochlorite 2%. After cleaning, the cyclophosphamide remaining on the areas was quantified by wipe sampling. Each cleaning solution was tested 3 times, with cleaning and wipe sampling being performed 5 times for each test. Results A total of 57 wipe samples were collected and analyzed. The average recovery efficiency was 121.690% (standard deviation 5.058%). The decontamination efficacy increased with the number of successive cleaning sessions: from 98.710% after session 1 to 99.997% after session 5 for quaternary ammonium; from 97.027% to 99.997% for sodium hypochlorite 0.02%; and from 98.008% to 100% for sodium hypochlorite 2%. Five additional cleaning sessions performed after the main study (with detergent and sodium hypochlorite 2%) were effective to complete the decontamination, leaving no detectable traces of the drug. Conclusions All of the cleaning solutions reduced contamination of biological safety cabinet workbenches exposed to a defined amount of cyclophosphamide. Quaternary ammonium and sodium hypochlorite (0.02% and 2%) had mean efficacy greater than 97% for removal of the initial quantity of the drug (107 pg) after the first cleaning session. When sodium hypochlorite 2% was used, fewer cleaning sessions were required to complete decontamination. Further studies should be conducted to identify optimal cleaning strategies to fully eliminate traces of hazardous drugs. PMID:29298999
49 CFR 393.78 - Windshield wiping and washing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... wipers, shall have the wiper system constructed and maintained such that the performance of the wipers... operations. Windshield wiping and washing systems need not be in working condition while a commercial motor...
Experimental Characterization of the Jet Wiping Process
NASA Astrophysics Data System (ADS)
Mendez, Miguel Alfonso; Enache, Adriana; Gosset, Anne; Buchlin, Jean-Marie
2018-06-01
This paper presents an experimental characterization of the jet wiping process, used in continuous coating applications to control the thickness of a liquid coat using an impinging gas jet. Time Resolved Particle Image Velocimetry (TR-PIV) is used to characterize the impinging gas flow, while an automatic interface detection algorithm is developed to track the liquid interface at the impact. The study of the flow interaction is combined with time resolved 3D thickness measurements of the liquid film remaining after the wiping, via Time Resolved Light Absorption (TR-LAbs). The simultaneous frequency analysis of liquid and gas flows allows to correlate their respective instability, provide an experimental data set for the validation of numerical studies and allows for formulating a working hypothesis on the origin of the coat non-uniformity encountered in many jet wiping processes.
Sarmaga, Don; DuBois, Jeffrey A; Lyon, Martha E
2011-01-01
Background Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. Method The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). Results No clinical (<0.3 mmol/liter) or statistical differences (p > .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (<0.3 mmol/liter). Conclusion The on-meter dosed glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. PMID:22226263
Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E
2011-11-01
Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical (<0.3 mmol/liter) or statistical differences (p > .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (<0.3 mmol/liter). The on-meter dosed glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.
Capillary microextraction: A new method for sampling methamphetamine vapour.
Nair, M V; Miskelly, G M
2016-11-01
Clandestine laboratories pose a serious health risk to first responders, investigators, decontamination companies, and the public who may be inadvertently exposed to methamphetamine and other chemicals used in its manufacture. Therefore there is an urgent need for reliable methods to detect and measure methamphetamine at such sites. The most common method for determining methamphetamine contamination at former clandestine laboratory sites is selected surface wipe sampling, followed by analysis with gas chromatography-mass spectrometry (GC-MS). We are investigating the use of sampling for methamphetamine vapour to complement such wipe sampling. In this study, we report the use of capillary microextraction (CME) devices for sampling airborne methamphetamine, and compare their sampling efficiency with a previously reported dynamic SPME method. The CME devices consisted of PDMS-coated glass filter strips inside a glass tube. The devices were used to dynamically sample methamphetamine vapour in the range of 0.42-4.2μgm -3 , generated by a custom-built vapour dosing system, for 1-15min, and methamphetamine was analysed using a GC-MS fitted with a ChromatoProbe thermal desorption unit. The devices showed good reproducibility (RSD<15%), and a curvilinear pre-equilibrium relationship between sampling times and peak area, which can be utilised for calibration. Under identical sampling conditions, the CME devices were approximately 30 times more sensitive than the dynamic SPME method. The CME devices could be stored for up to 3days after sampling prior to analysis. Consecutive sampling of methamphetamine and its isotopic substitute, d-9 methamphetamine showed no competitive displacement. This suggests that CME devices, pre-loaded with an internal standard, could be a feasible method for sampling airborne methamphetamine at former clandestine laboratories. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Brominated Flame Retardants and Organophosphate Esters in Preschool Dust and Children's Hand Wipes.
Larsson, Kristin; de Wit, Cynthia A; Sellström, Ulla; Sahlström, Leena; Lindh, Christian H; Berglund, Marika
2018-04-17
Children spend a considerable part of their day in preschool, where they may be exposed to hazardous chemicals in indoor dust. In this study, brominated flame retardants (BFRs) and organophosphate esters (OPEs) were analyzed in preschool dust ( n = 100) and children's hand wipe samples ( n = 100), and diphenyl phosphate (DPHP) was analyzed in urine ( n = 113). Here we assessed children's exposure via dust, identified predictors for chemicals in dust, and studied correlations between different exposure measures. The most abundant BFRs in dust were decabromodiphenyl ether (BDE-209) and decabromodiphenyl ethane (DBDPE) found at median levels of 270 and 110 ng/g dust, respectively. Tris(2-butoxyethyl) phosphate (TBOEP) was the most abundant OPE, found at a median level of 79 000 ng/g dust. For all OPEs and some BFRs, there were significant correlations between the levels in dust and hand wipes. In addition, triphenyl phosphate (TPHP) in preschool dust was significantly correlated with the corresponding metabolite DPHP in children's urine. The levels of pentaBDEs in dust were higher in older preschools compared with newer, whereas levels of DBDPE were higher in newer preschools. Children's estimated intakes of individual BFRs and OPEs via preschool dust were below available health-based reference values. However, there are uncertainties about the potential health effects of some emerging BFRs and OPEs.
Salin, J T; Salkinoja-Salonen, M; Salin, P J; Nelo, K; Holma, T; Ohtonen, P; Syrjälä, H
2017-04-01
Indoor microbial toxicity is suspected to cause some building-related symptoms, but supporting epidemiological data are lacking. We examined whether the in vitro toxicity of indoor samples from school buildings was associated with work-related health symptoms (building-related symptoms, BRS). Administrators of the Helsinki City Real Estate Department selected 15 schools for the study, and a questionnaire on symptoms connected to work was sent to the teachers in the selected schools for voluntary completion. The cellular toxicity of classroom samples was determined by testing substances extracted from wiped indoor dust and by testing microbial biomass that was cultured on fallout plates. Boar sperm cells were used as indicator cells, and motility loss was the indicator for toxic effects. The effects were expressed as the half maximal effective concentration (EC 50 ) at which >50% of the exposed boar sperm cells were immobile compared to vehicle control. Completed symptom questionnaires were received from 232 teachers [median age, 43 years; 190 (82.3%) women] with a median time of 6 years working at their school. Samples from their classrooms were available and were assessed for cellular toxicity. The Poisson regression model showed that the impact of extracts of surface-wiped school classroom dust on teacher work-related BRS was 2.8-fold (95% CI: 1.6-4.9) higher in classrooms with a toxic threshold EC 50 of 6µgml -1 versus classrooms with insignificant EC 50 values (EC 50 >50µgml -1 ); P<0.001. The number of symptoms that were alleviated during vacation was higher in school classrooms with high sperm toxicity compared to less toxic sites; the RR was 1.9 (95% CI: 1.1-3.3, P=0.03) for wiped dust extracts. Teachers working in classrooms where the samples showed high sperm toxicity had more BRS. The boar sperm cell motility inhibition assay appears promising as a tool for demonstrating the presence of indoor substances associated with BRS. Copyright © 2017 Elsevier Inc. All rights reserved.
EPA is approximately 20 months into a project to evaluate the performance of wood coatings as a way to prevent arsenic, chromium and copper exposure from the surfaces of CCA treated wood. Potential dermal exposure, as measured by wipe sampling dislodgeable CCA chemical from wood ...
The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography electron capture detector (GC/ECD) of pesticides in a variety of matrices, including air, house dust, soil, handwipes, and surface wipes. Other SOP's detail the extract...
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
Hoskins, Daniel L; Zhang, Xiaoyuan; Hickner, Michael A; Logan, Bruce E
2014-11-01
Separators are used to protect cathodes from biofouling and to avoid electrode short-circuiting, but they can adversely affect microbial fuel cell (MFC) performance. A spray method was used to apply a polyvinyl alcohol (PVA) separator to the cathode. Power densities were unaffected by the PVA separator (339±29mW/m(2)), compared to a control lacking a separator in a low conductivity solution (1mS/cm) similar to wastewater. Power was reduced with separators in solutions typical of laboratory tests (7-13mS/cm), compared to separatorless controls. The PVA separator produced more power in a separator assembly (SEA) configuration (444±8mW/m(2)) in the 1mS/cm solution, but power was reduced if a PVA or wipe separator was used in higher conductivity solutions with either Pt or activated carbon catalysts. Spray and cast PVA separators performed similarly, but the spray method is preferred as it was easier to apply and use. Copyright © 2014 Elsevier Ltd. All rights reserved.
Design concept definition study for an improved shuttle waste collection subsystem
NASA Technical Reports Server (NTRS)
1984-01-01
A no-risk approach for developing an Improved Waste Collection Subsystem (WCS) for the shuttle orbiter is described. The GE Improved WCS Concept builds on the experience of 14 Shuttle missions with over 400 man-days of service. This concept employs the methods of the existing flight-proven mature design, augmenting them to eliminate foreseen difficulties and to fully comply with the design requirements. The GE Improved WCS Concept includes separate storage for used wipes. Compaction of the wipes provides a solution to the capacity problem, fully satisfying the 210 man-day storage requirement. The added feature of in-flight serviceable storage space for the wipes creates a variable capacity feature which affords redundancy in the event of wipes compaction system failure. Addition of features permitting in-flight servicing of the feces storage tank creates a variable capacity WCS with easier post-flight servicing to support rapid turnaround of the Shuttle orbiter. When these features are combined with a vacuum pump to evacuate wipes and fecal storage tanks through replaceable odor/bacteria filters to the cabin, the GE Improved WCS satisfies the known requirements for Space Station use, including no venting to space.
Yu, JiaDe; Treat, James; Chaney, Keri; Brod, Bruce
2016-01-01
Allergic contact dermatitis in young children may be an under-recognized cause of perineal dermatitis. The diapered infant skin is uniquely susceptible to allergic contact dermatitis because of more permeable neonatal skin, a moist environment, frequent contact with irritants and resultant skin barrier breakdown, and exposure to topical products such as diaper wipes, diaper preparations, and disposable diapers. To our knowledge, potential allergens in these products have not been thoroughly catalogued or studied. We explore and review potential allergenic ingredients in diaper wipes, topical diaper preparations, and disposable diapers. We analyzed 63 diaper wipes, 41 topical diaper preparations, and the 3 top selling diaper brands available from two of the largest retailers in the United States. Each potential allergen is discussed, and epidemiologic studies of rates of sensitization to potential allergens in children are also reported. Botanical extracts, including members of the Compositae family, were the most commonly represented potential allergen in both diaper wipes and topical preparations. Other potential allergens identified with high frequency include α-tocopherol, fragrances, propylene glycol, parabens, iodopropynyl butylcarbamate, and lanolin. Frequent culprits such as formaldehyde releasers and methylchloroisothiazolinone/methylisothiazolinone were not prevalent in our analyzed products.
2007-08-01
Characterization (OHM 1998). From the plot, it is clear that the HEU dominates DU in the overall isotopic characteristic. Among the three uranium ... isotopes , 234U comprised about 90 % of the total activity, including naturally-occurring background sources. However, in comparison to the WGP, uranium ...listed for a few sampling locations that had isotopic plutonium analysis of wipe samples. Figure A-19 contains a scatterplot of the paired Table 4-13
Field Measurements of Inadvertent Ingestion Exposure to Metals.
Gorman Ng, Melanie; MacCalman, Laura; Semple, Sean; van Tongeren, Martie
2017-11-10
The determinants of inadvertent occupational ingestion exposure are poorly understood, largely due to a lack of available exposure measurement data. In this study, perioral exposure wipes were used as a surrogate for inadvertent ingestion exposure to measure exposure to eight metals (chromium, nickel, aluminium, cobalt, lead, arsenic, manganese, and tin) among 38 workers at 5 work sites in the UK. This work was done alongside a previously reported observational study of hand/object-to-mouth contact frequency. Systematic wipes of the perioral area, and of both hands were taken with proprietary cellulose wipes pre-moistened with deionized water. Measurements were taken at the beginning, middle and end of the shift. Mixed-effect models of exposure measurements were built with area of skin sampled, time during shift, and job group entered as fixed effects and worker identification as a random effect. Linear regression modelling was used to study the effect of hand/object-to-mouth contact frequency on perioral exposure, adjusting for the measured exposure on the hand and observed respirator use. Hand and perioral exposure measurements were correlated with one another (r = 0.79) but mass per unit area exposure was significantly higher on the perioral area than on the hands for seven of the metals (at P < 0.05). There were no significant differences between measurements taken at the middle or the end of the shift for five of the metals suggesting that dermal loading may remain relatively constant for much of the workday. This applies to both hand and perioral measurements. In linear regression modelling there was no relationship between hand/object-to-mouth contact frequency and perioral exposure, but hand exposure was significantly positively related to perioral exposure and workers who used respirators had significantly higher perioral exposure than those who did not. The results suggest the levels of exposure on the hand and respirator use are important determinants of potential inadvertent ingestion exposure. The results did not demonstrate a relationship between perioral exposure and hand-to-mouth contact frequency. Perioral wipe sampling may be a useful surrogate measure for exposure by the inadvertent ingestion route, but further research is required to confirm the link between perioral levels and actual exposure, measured using biological monitoring. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Lei, Hao; Jones, Rachael M; Li, Yuguo
2017-01-18
Cleaning of environmental surfaces in hospitals is important for the control of methicillin-resistant Staphylococcus aureus (MRSA) and other hospital-acquired infections transmitted by the contact route. Guidance regarding the best approaches for cleaning, however, is limited. In this study, a mathematical model based on ordinary differential equations was constructed to study MRSA concentration dynamics on high-touch and low-touch surfaces, and on the hands and noses of two patients (in two hospitals rooms) and a health care worker in a hypothetical hospital environment. Two cleaning interventions - whole room cleaning and wipe cleaning of touched surfaces - were considered. The performance of the cleaning interventions was indicated by a reduction in MRSA on the nose of a susceptible patient, relative to no intervention. Whole room cleaning just before first patient care activities of the day was more effective than whole room cleaning at other times, but even with 100% efficiency, whole room cleaning only reduced the number of MRSA transmitted to the susceptible patient by 54%. Frequent wipe cleaning of touched surfaces was shown to be more effective that whole room cleaning because surfaces are rapidly re-contaminated with MRSA after cleaning. Wipe cleaning high-touch surfaces was more effective than wipe cleaning low-touch surfaces for the same frequency of cleaning. For low wipe cleaning frequency (≤3 times per hour), high-touch surfaces should be targeted, but for high wipe cleaning frequency (>3 times per hour), cleaning should target high- and low-touch surfaces in proportion to the surface touch frequency. This study reproduces the observations from a field study of room cleaning, which provides support for the validity of our findings. Daily whole room cleaning, even with 100% cleaning efficiency, provides limited reduction in the number of MRSA transmitted to susceptible patients via the contact route; and should be supplemented with frequent targeted cleaning of high-touch surfaces, such as by a wipe or cloth containing disinfectant.
United States Air Force Wipe Solvent Testing
NASA Technical Reports Server (NTRS)
Hornung, Steven D.; Beeson, Harold D.
2000-01-01
The Wright-Patterson Air Force Base (WPAFB), as part of the Air Force Material Command, requested that NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) conduct testing and analyses in support of the United States Air Force Wipe Solvent Development Project. The purpose of the wipe solvent project is to develop an alternative to be used by Air Force flight line and maintenance personnel for the wipe cleaning of oxygen equipment. This report provides material compatibility, liquid oxygen (LOX) mechanical impact, autogenous ignition temperature (AIT), and gauge cleaning test data for some of the currently available solvents that may be used to replace CFC-113 and methyl chloroform. It provides data from previous WSTF test programs sponsored by the Naval Sea Systems Command, the Kennedy Space Center, and other NASA programs for the purpose of assisting WP AFB in identifying the best alternative solvents for validation testing.
Karoly, William J; Flatley, John J; Stevenson, Ralph D; Bowers, John D
2004-12-01
Air monitoring data were collected from industrial hygiene surveys over an 8-year period in oriented strand board (OSB) mills. Personal samples were taken to evaluate potential employee exposures to MDI. Area samples were taken to determine the effectiveness of control measures used in the mills to prevent fugitive emissions of wood dust, MDI, and MDI-coated wood dust from the OSB manufacturing process. Personal sampling results (578 samples covering 11 different job categories) ranged from 0.0002-0.524 mg/m3, with a GM = 0.001 and GSD = 3.71. Area sampling results (1657 samples covering 14 stationary locations in the mills) ranged from 0.0002-2.5 mg/m3, with a GM = 0.004 and GSD = 5.52. The statistical range of the data suggests high variability. While exposures to MDI above the established limits (0.051 mg/m3, 8-hour time-weighted average, 0.2 mg/m3, ceiling) can and do occur when engineering controls are not maintained and/or proper work practices and personal protective equipment are not followed/used for certain high exposure potential tasks, the data indicate that over 97% of the personal and 92% of the area sampling results are less than 0.051 mg/m3. Wipe testing was performed to determine the presence of removable, unreacted diisocyanates (NCO functional groups)from various surfaces. Positive results were found in about 13% of the wipe tests on surfaces confined to the blender, forming line, and hopper deck process areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Que Hee, S.S.; Peace, B.; Clark, C.S.
Efficient sampling methods to recover lead-containing house dust and hand dust have been evolved so that sufficient lead is collected for analysis and to ensure that correlational analyses linking these two parameters to blood lead are not dependent on the efficiency of sampling. Precise collection of loose house dust from a 1-unit area (484 cmS) with a Tygon or stainless steel sampling tube connected to a portable sampling pump (1.2 to 2.5 liters/min) required repetitive sampling (three times). The Tygon tube sampling technique for loose house dust <177 m in diameter was around 72% efficient with respect to dust weightmore » and lead collection. A representative house dust contained 81% of its total weight in this fraction. A single handwipe for applied loose hand dust was not acceptably efficient or precise, and at least three wipes were necessary to achieve recoveries of >80% of the lead applied. House dusts of different particle sizes <246 m adhered equally well to hands. Analysis of lead-containing material usually required at least three digestions/decantations using hot plate or microwave techniques to allow at least 90% of the lead to be recovered. It was recommended that other investigators validate their handwiping, house dust sampling, and digestion techniques to facilitate comparison of results across studies. The final methodology for the Cincinnati longitudinal study was three sampling passes for surface dust using a stainless steel sampling tube; three microwave digestion/decantations for analysis of dust and paint; and three wipes with handwipes with one digestion/decantation for the analysis of six handwipes together.« less
Development, validation and testing of a skin sampling method for assessment of metal exposure.
Erfani, Behnaz; Midander, Klara; Lidén, Carola; Julander, Anneli
2017-07-01
Nickel, cobalt and chromium are frequent skin sensitizers. Skin exposure results in eczema in sensitized individuals, the risk being related to the skin dose. To develop a self-sampling method for quantification of skin exposure to metals, to validate the method, and to assess its feasibility. Defined metal doses (0.01-5 µg) were applied to the fingers of 5 participants. Skin areas (2 cm 2 ) were sampled with 1% HNO 3 , either as 0.1 ml on a swab, or as 0.5 ml on a wipe. Furthermore, 17 participants performed self-sampling by swab after 2 h of leisure activity. Samples were extracted in 1% HNO 3 and analysed by inductively coupled plasma mass spectrometry. The sampling efficiency by swab was 46%, as compared with 93% for acid wipe sampling, for all tested doses. Most metal from the skin dose was detected in the first swab (33-43%). Despite lower sampling efficiency by swab, skin doses of metals following 2 h of leisure activity without hand washing were quantified in all participants, and ranged from 0.0016 to 0.15 µg/cm 2 , from 0.00014 to -0.0020 µg/cm 2 and from 0.00048 to -0.027 µg/cm 2 for nickel, cobalt, and chromium, respectively. The results indicate a future potential of skin sampling by swab to detect and monitor metals on skin by self-sampling. This will contribute to better knowledge of metal skin exposure among dermatitis patients, workers, and the general population. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Liao, Chunyang; Kannan, Kurunthachalam
2014-03-15
Parabens (alkyl esters of p-hydroxybenzoic acid) are widely used as antimicrobial preservatives in personal care products, pharmaceuticals, and foodstuffs. Although parabens have been reported to be used as antimicrobials in certain types of papers (e.g., wet sanitary or hygiene wipes), little is known about the occurrence of these compounds in paper products. In this study, we determined the concentrations of six paraben analogs, methyl (MeP), ethyl (EtP), propyl (PrP), butyl (BuP), benzyl (BzP), and heptyl parabens (HepP), in 253 paper products divided into 18 categories, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). At least one of the six parabens was detected in almost all (detection rate: 98%) paper samples, and the total concentrations (∑PBs; sum of six parabens) ranged from 1.85 to 3,220,000 ng/g (geometric mean (GM): 103; median: 55.1 ng/g). Sanitary wipes contained very high concentrations of ∑PBs (GM: 8300 ng/g). Paper currencies, tickets, business cards, food cartons, flyers, and newspapers contained notable concentrations of ∑PBs, and the GM concentrations in these paper categories were on the order of a few tens to thousands of nanograms per gram. One source of parabens in paper products is the use of these chemicals as antifungal agents. MeP and PrP were the predominant analogs, accounting for approximately 62% and 16% of the total concentrations of parabens, respectively. On the basis of measured concentrations and frequency of handling of paper products, we estimated the daily intake (EDI) of parabens through dermal absorption. The GM and 95th percentile EDI values were 6.31 and 2050 ng/day, respectively, for the general population. Among the paper categories analyzed, sanitary wipes contributed to the majority (>90%) of the exposures. Copyright © 2013 Elsevier B.V. All rights reserved.
Residual Viral and Bacterial Contamination of Surfaces after Cleaning and Disinfection
Tuladhar, Era; Hazeleger, Wilma C.; Koopmans, Marion; Zwietering, Marcel H.; Beumer, Rijkelt R.
2012-01-01
Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses, rotavirus, poliovirus, parechovirus, adenovirus, influenza virus, Staphylococcus aureus, and Salmonella enterica from artificially contaminated stainless steel surfaces. After a single wipe with water, liquid soap, or 250-ppm free chlorine solution, the numbers of infective viruses and bacteria were reduced by 1 log10 for poliovirus and close to 4 log10 for influenza virus. There was no significant difference in residual contamination levels after wiping with water, liquid soap, or 250-ppm chlorine solution. When a single wipe with liquid soap was followed by a second wipe using 250- or 1,000-ppm chlorine, an extra 1- to 3-log10 reduction was achieved, and except for rotavirus and norovirus genogroup I, no significant additional effect of 1,000 ppm compared to 250 ppm was found. A reduced correlation between reduction in PCR units (PCRU) and reduction in infectious particles suggests that at least part of the reduction achieved in the second step is due to inactivation instead of removal alone. We used data on infectious doses and transfer efficiencies to estimate a target level to which the residual contamination should be reduced and found that a single wipe with liquid soap followed by a wipe with 250-ppm free chlorine solution was sufficient to reduce the residual contamination to below the target level for most of the pathogens tested. PMID:22941071
Residual viral and bacterial contamination of surfaces after cleaning and disinfection.
Tuladhar, Era; Hazeleger, Wilma C; Koopmans, Marion; Zwietering, Marcel H; Beumer, Rijkelt R; Duizer, Erwin
2012-11-01
Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses, rotavirus, poliovirus, parechovirus, adenovirus, influenza virus, Staphylococcus aureus, and Salmonella enterica from artificially contaminated stainless steel surfaces. After a single wipe with water, liquid soap, or 250-ppm free chlorine solution, the numbers of infective viruses and bacteria were reduced by 1 log(10) for poliovirus and close to 4 log(10) for influenza virus. There was no significant difference in residual contamination levels after wiping with water, liquid soap, or 250-ppm chlorine solution. When a single wipe with liquid soap was followed by a second wipe using 250- or 1,000-ppm chlorine, an extra 1- to 3-log(10) reduction was achieved, and except for rotavirus and norovirus genogroup I, no significant additional effect of 1,000 ppm compared to 250 ppm was found. A reduced correlation between reduction in PCR units (PCRU) and reduction in infectious particles suggests that at least part of the reduction achieved in the second step is due to inactivation instead of removal alone. We used data on infectious doses and transfer efficiencies to estimate a target level to which the residual contamination should be reduced and found that a single wipe with liquid soap followed by a wipe with 250-ppm free chlorine solution was sufficient to reduce the residual contamination to below the target level for most of the pathogens tested.
Casey, Anna L; Karpanen, Tarja J; Nightingale, Peter; Elliott, Tom S J
2018-01-01
The optimal decontamination method for needle-free connectors is still unresolved. The objective of this study was to determine if a continuous passive disinfection cap is as effective as standard cleaning for the microbial decontamination of injection ports of two types of needle-free connectors. The injection ports of needle-free connectors were inoculated with Staphylococcus aureus and allowed to dry. Disinfection caps containing 70% ( v / v ) isopropyl alcohol (IPA) were attached to the connectors for one, three or 7 days and were compared with needle-free connectors cleaned with 2% ( w / v ) chlorhexidine gluconate (CHG) in 70% ( v/v ) IPA. The number of S. aureus remaining on the injection ports was evaluated. Median log 10 reductions and 95% confidence interval (CI) were calculated and data analyzed using the Mann-Whitney test. The application of the disinfection cap resulted in a significantly higher reduction in S. aureus than the 2% ( w / v ) CHG in 70% ( v / v ) IPA wipe, achieving a > 5 Log 10 reduction in CFU at each time point. The disinfection caps resulted in a significantly higher reduction in S.aureus on the injection ports when compared to the use of a 2% ( w/v ) CHG in 70% ( v/v ) IPA wipe. This offers an explanation for the lower rates of central-line associated bloodstream infection (CLABSI) associated with the use of disinfection caps reported in clinical studies.
Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal
2011-05-01
Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
Middle School Girls Sample "Hard Hat" Life at Construction Camp
ERIC Educational Resources Information Center
Brown, Aneeta
2013-01-01
On a Monday morning in July, a fan as tall as a refrigerator churned noisily in the cavernous classroom. As the outdoor temperature crept higher, teenage girls wearing hardhats and safety glasses wiped perspiration and sawdust from their faces. This was not a field trip. This was the second hour of camp at Ranken Technical College in St. Louis,…
Indoor air, surface wipes (floors, table tops and window sills) and floor dust samples were collected at multiple locations within 11 occupied and 2 unoccupied homes both prior to and following lawn application of the herbicide 2,4-D. Residue measurements were made over period...
This is a regulation page for the final rule EPA issued on July 31, 2013 that modifies the hazardous waste management regulations for solvent-contaminated wipes under the Resource Conservation and Recovery Act (RCRA).
False-Negative Rate and Recovery Efficiency Performance of a Validated Sponge Wipe Sampling Method
Piepel, Greg F.; Boucher, Raymond; Tezak, Matt; Amidan, Brett G.; Einfeld, Wayne
2012-01-01
Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10 × 10−3 to 1.86 CFU/cm2). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD90 (≥1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm2 on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions. PMID:22138998
Qiu, Tian Yu; Yeo, Sharon; Tong, Louis
2018-01-01
Demodex infestations cause blepharitis and are difficult to treat. Recently, a new type of eyelid wipes with terpenoids has been found effective. We aim to evaluate patient satisfaction after short-term use and compare two teaching modalities on the techniques of use. Eligible participants were taught to use eyelid wipes (Cliradex ® ) by either live or online video demonstration based on random allocation. Participants used the wipes twice daily for a week. All participants had prior evaluation of socioeconomic status, dry eye symptoms, and meibomian gland features. After 1 week, competence of use was assessed by participants showing their technique to the investigator, and a questionnaire on comfort, ease, and convenience of use was administered. Higher scores indicate greater satisfaction, and these levels are compared among the two teaching modalities using chi square. A total of 50 participants were recruited, with a mean age of 42±16 years, and 88% of the participants were females. Overall, median comfort level was 4.0 (range: 1-6), ease level was 5.0 (3-6), and convenience level was 5.0 (2-6). Median stinging was 2.0 (1-4), which corresponded to some but mild stinging. The median competence level was 4.0 (2-4), which corresponded to excellent competence. These satisfactory levels (ease, comfort, and convenience) experienced were not significantly associated with different socioeconomic indicators, that is, housing type, income, highest education level, and were not different between teaching methods ( p >0.05). Short-term use of Cliradex eyelid wipes seems to be acceptable to most people. The teaching instructions before using these wipes were equally effective - whether live or online video demonstration was used.
Qiu, Tian Yu; Yeo, Sharon; Tong, Louis
2018-01-01
Purpose Demodex infestations cause blepharitis and are difficult to treat. Recently, a new type of eyelid wipes with terpenoids has been found effective. We aim to evaluate patient satisfaction after short-term use and compare two teaching modalities on the techniques of use. Patients and methods Eligible participants were taught to use eyelid wipes (Cliradex®) by either live or online video demonstration based on random allocation. Participants used the wipes twice daily for a week. All participants had prior evaluation of socioeconomic status, dry eye symptoms, and meibomian gland features. After 1 week, competence of use was assessed by participants showing their technique to the investigator, and a questionnaire on comfort, ease, and convenience of use was administered. Higher scores indicate greater satisfaction, and these levels are compared among the two teaching modalities using chi square. Results A total of 50 participants were recruited, with a mean age of 42±16 years, and 88% of the participants were females. Overall, median comfort level was 4.0 (range: 1–6), ease level was 5.0 (3–6), and convenience level was 5.0 (2–6). Median stinging was 2.0 (1–4), which corresponded to some but mild stinging. The median competence level was 4.0 (2–4), which corresponded to excellent competence. These satisfactory levels (ease, comfort, and convenience) experienced were not significantly associated with different socioeconomic indicators, that is, housing type, income, highest education level, and were not different between teaching methods (p>0.05). Conclusion Short-term use of Cliradex eyelid wipes seems to be acceptable to most people. The teaching instructions before using these wipes were equally effective – whether live or online video demonstration was used. PMID:29379270
Melstrom, Paul; Koszowski, Bartosz; Thanner, Meridith Hill; Hoh, Eunha; King, Brian; Bunnell, Rebecca; McAfee, Tim
2017-09-01
Few studies have examined the extent of inhalation or dermal contact among bystanders following short-term, secondhand e-cigarette exposure. Measure PM2.5 (particles < 2.5 microns), UF (ultrafine particles < 100 nm), and nicotine in air and deposited on surfaces and clothing pre-/during/post- a short-term (2-hour) e-cigarette exposure. E-cigarettes were used ad libitum by three experienced users for 2 hours during two separate sessions (disposable e-cigarettes, then tank-style e-cigarettes, or "tanks") in a 1858 ft3 room. We recorded: uncorrected PM2.5 (using SidePak); UF (using P-Trak); air nicotine concentrations (using air samplers; SKC XAD-4 canisters); ambient air exchange rate (using an air capture hood). Wipe samples were taken by wiping 100 cm2 room surfaces pre- and post- both sessions, and clean cloth wipes were worn during the exposure and collected at the end. Uncorrected PM2.5 and UF were higher (p < .0001) during sessions than before or after. Median PM2.5 during exposure was higher using tanks (0.515 mg/m3) than disposables (0.035 mg/m3) (p < .0001). Median UF during exposure was higher using disposables (31 200 particles/cm3) than tanks (25 200 particles/cm3)(p < .0001). Median air nicotine levels were higher (p < .05) during both sessions (disposables = 0.697 ng/L, tanks = 1.833 ng/L) than before (disposables = 0.004 ng/L, tanks = 0.010 ng/L) or after (disposables = 0.115 ng/L, tanks = 0.147 ng/L). Median accumulation rates of nicotine on surface samples were 2.1 ng/100 cm2/h using disposables and 4.0 ng/100 cm2/h using tanks; for cloth samples, it was 44.4 ng/100 cm2/h using disposables and 69.6 ng/100 cm2/h using tanks (p < .01). Mean room ventilation rate was ~5 air changes per hour during both sessions. Short-term e-cigarette use can produce: elevated PM2.5; elevated UF; nicotine in the air; and accumulation of nicotine on surfaces and clothing. Short-term indoor e-cigarette use produced accumulation of nicotine on surfaces and clothing, which could lead to dermal exposure to nicotine. Short-term e-cigarette use produced elevated PM2.5 and ultrafine particles, which could lead to secondhand inhalation of these particles and any chemicals associated with them by bystanders. We measured significant differences in PM2.5 and ultrafine particles between disposable e-cigarettes and tank-style e-cigarettes, suggesting a difference in the exposure profiles of e-cigarette products. Published by Oxford University Press on behalf of Society for Research on Nicotine and Tobacco 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
ODC-Free Solvent Implementation for Phenolics Cleaning
NASA Technical Reports Server (NTRS)
Wurth, Laura; Biegert, Lydia; Lamont, DT; McCool, Alex (Technical Monitor)
2001-01-01
During phenolic liner manufacture, resin-impregnated (pre-preg) bias tape of silica, glass, or carbon cloth is tape-wrapped, cured, machined, and then wiped with 1,1,1 tri-chloroethane (TCA) to remove contaminants that may have been introduced during machining and handling. Following the TCA wipe, the machined surface is given a resin wet-coat and over-wrapped with more prepreg and cured. A TCA replacement solvent for these wiping operations must effectively remove both surface contaminants, and sub-surface oils and greases while not compromising the integrity of this interface. Selection of a TCA replacement solvent for phenolic over-wrap interface cleaning began with sub-scale compatibility tests with cured phenolics. Additional compatibility tests included assessment of solvent retention in machined phenolic surfaces. Results from these tests showed that, while the candidate solvent did not degrade the cured phenolics, it was retained in higher concentrations than TCA in phenolic surfaces. This effect was most pronounced with glass and silica cloth phenolics with steep ply angles relative to the wiped surfaces.
Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong-geller, Elizabeth; Valdez, Yolanda E; Shou, Yulin
2009-01-01
Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs ormore » wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.« less
Hong-Geller, E; Valdez, Y E; Shou, Y; Yoshida, T M; Marrone, B L; Dunbar, J M
2010-04-01
We will validate sample collection methods for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. We evaluated the sample recovery efficiencies of two collection methods - swabs and wipes - for both nonvirulent and virulent strains of Bacillus anthracis and Yersinia pestis from four types of nonporous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than nonvirulent strains. For the two nonvirulent strains, collection efficiency was similar between all four surfaces, albeit B. anthracis Sterne exhibited higher levels of recovery compared to Y. pestis A1122. In contrast, recovery of B. anthracis Ames spores and Y. pestis CO92 from the hydrophilic glass or stainless steel surfaces was generally more efficient compared to collection from the hydrophobic vinyl and plastic surfaces. Our results suggest that surface hydrophobicity may play a role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to the validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.
Kurashige, E Jessica Ohashi; Oie, Shigeharu; Furukawa, H
2016-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) can contaminate environmental surfaces that are frequently touched by the hands of patients with MRSA colonization/infection. There have been many studies in which the presence or absence of MRSA contamination was determined but no studies in which MRSA contamination levels were also evaluated in detail. We evaluated MRSA contamination of environmental surfaces (overbed tables, bed side rails, and curtains) in the rooms of inpatients from whom MRSA was isolated via clinical specimens. We examined the curtains within 7-14 days after they had been newly hung. The environmental surfaces were wiped using gauze (molded gauze for wiping of surface bacteria; 100% cotton, 4cm×8cm) moistened with sterile physiological saline. The MRSA contamination rate and mean counts (range) were 25.0% (6/24 samples) and 30.6 (0-255)colony-forming units (cfu)/100cm(2), respectively, for the overbed tables and 31.6% (6/19 samples) and 159.5 (0-1620)cfu/100cm(2), respectively, for the bed side rails. No MRSA was detected in 24 curtain samples. The rate of MRSA contamination of environmental surfaces was high for the overbed tables and bed side rails but low for the curtains. Therefore, at least until the 14th day of use, frequent disinfection of curtains may be not necessary. Copyright © 2016. Published by Elsevier Editora Ltda.
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
Morgan, Marsha K; Nash, Maliha; Barr, Dana Boyd; Starr, James M; Scott Clifton, M; Sobus, Jon R
2018-03-01
Bisphenol A (BPA) is commonly manufactured to make polycarbonate plastics and epoxy resins for use in consumer products and packaged goods. BPA has been found in several different types of environmental media (e.g., food, dust, and air). Many cross-sectional studies have frequently detected BPA concentrations in adult urine samples. However, limited data are available on the temporal variability and important predictors of urinary BPA concentrations in adults. In this work, the major objectives were to: 1) quantify BPA levels in duplicate-diet solid food, drinking water, hard floor surface wipe, and urine samples (first-morning void [FMV], bedtime, and 24-h) collected from adults over a six-week monitoring period; 2) determine the temporal variability of urinary BPA levels using concentration, specific gravity (SG) adjusted, creatinine (CR) adjusted, and excretion rate values, and; 3) examine associations between available study factors and urinary BPA concentrations. In 2009-2011, a convenience sample of 50 adults was recruited from residential settings in North Carolina. The participants completed diaries and collected samples during weeks 1, 2, and/or 6 of a six-week monitoring period. BPA was detected in 38%, 4%, and 99% of the solid food (n=775), drinking water (n=50), and surface wipe samples (n=138), respectively. Total BPA (free plus conjugated) was detected in 98% of the 2477 urine samples. Median urinary BPA levels were 2.07ng/mL, 2.20ng/mL-SG, 2.29ng/mg, and 2.31ng/min for concentration, SG-adjusted, CR-adjusted, and excretion rate values, respectively. The intraclass correlation coefficient (ICC) estimates for BPA showed poor reproducibility (≤0.35) for all urine sample types and methods over a day, week, and six weeks. CR-adjusted bedtime voids collected over six-weeks required the fewest, realistic number of samples (n=11) to obtain a reliable biomarker estimate (ICC=0.80). Results of linear mixed-effects models showed that sex, race, season, and CR-level were all significant predictors (p<0.05) of the adults' urinary BPA concentrations. BPA levels in the solid food and surface wipe samples did not contribute significantly to the participants' urinary BPA concentrations. However, a significant positive relationship was observed between solid food intake and urine-based estimates of BPA dose, when aggregated over 24-h periods. Ingestion of BPA via solid food explained only about 20% of the total dose (at the median of the dose distribution), suggesting that these adults were likely exposed to other major unknown (non-dietary) sources of BPA in their everyday environments. Published by Elsevier Ltd.
Due to the potential for ingestion of chromated copper arsenate (CCA) by the hand-to-mouth activities of young children who contact CCA treated wood, EPA has used wipe samples to study the potential benefits of paint-like coatings on CCA treated wood. Citizens who may be concern...
Kawasaki, Kazuo; Horikawa, Keiji; Sakai, Hideo
2017-04-01
Magnetic biomonitoring techniques and in situ topsoil magnetic susceptibility measurements have been shown to be rapid, cost-effective, and useful methods for investigating roadside pollution. However, combustible vegetation in samples makes it very difficult to use them in high-temperature magnetic experiments although the thermal alteration of spontaneous magnetization is a fundamental magnetic property and can be used to identify reliably the magnetic minerals. Here, we report the first magnetic biomonitoring results of dust deposited on plant leaves along the Tateyama-Kurobe Alpine route at the highly protected Midagahara wetland areas of Mt. Tateyama in Toyama, Japan. In-field magnetic susceptibility from 15 sites (161 points) shows higher susceptibilities near the roadside. Dust deposited on the leaves of Sasa kurilensis, or dwarf bamboo, has been wiped off at 12 sites (64 samples) with a commercial ethanol wipe sheet or silica wool damped in ethanol and subjected to rock magnetic analyses. Thermomagnetic remanence curves and low-temperature behaviors for samples collected near the roadside using silica wool show clearly that the main magnetic mineral in the dust is partially oxidized magnetite. Further, detailed rock magnetic analyses and elemental analyses of leaves in the study area indicate that (a) the magnetic mineralogy on leaves' surface is consistent throughout the study area and (b) higher saturation isothermal remanent magnetization intensities as well as higher concentrations of Pb, Fe, Cr, and Y are observed near the roadside, i.e., the closer to the roadside, the more anthropogenic materials, including partially oxidized magnetite, are present. Also, microscopic observations show the lack of spherical grains, indicating that dust on the roadside leaves is derived from passing vehicle rather than industrial process. Both rock magnetic and geochemical results show that S. kurilensis would be an excellent candidate for investigating air pollution. Also, the proposed wiping-off method of collecting dust from plant surfaces is an effective non-destructive method that can be applied even in highly restricted collection areas, because detailed magnetic mineralogy, including superparamagnetic minerals, could be determined with the use of silica wool for use in both high- and low-temperature experiments.
A MULTI-RESIDUE METHOD FOR THE ANALYSIS OF INSECTICIDES COLLECTED ON COTTON SURFACE WIPES
A method was developed for the extraction, clean-up, and analysis of multiple pesticides from cotton wipe media used in human exposure studies to collect residues from residential hard surfaces. Measurements of pesticides are critical for estimating dermal and indirect ingestion ...
Astronaut Nelson wipes off helmet visor in the middeck of Shuttle Challenger
NASA Technical Reports Server (NTRS)
1984-01-01
Astronaut George D. Nelson, 41-C mission specialist, wipes off his helmet visor in the middeck of Shuttle Challenger. Astronaut James D. van. Hoften, is seen in the background. Both crew members are wearing the liquid cooled undergarments for the extravehicular mobility unit (EMU).
Scherer, Emeline; Rocchi, Steffi; Reboux, Gabriel; Vandentorren, Stéphanie; Roussel, Sandrine; Vacheyrou, Mallory; Raherison, Chantal; Millon, Laurence
2014-01-01
The aim of the present study was to assess performance, feasibility and relevance of a Standard Operational Procedure (SOP) for large-scale use in the microbial analysis of children's indoor environments. We analyzed dust settled on Electrostatic Dust Fall Collectors (EDCs) by using qPCR which targeted 6 molds, 3 bacteria and 1 mite, chosen for their involvement in allergic or inflammatory processes. Six types of commercialized electrostatic wipes were tested for their releasing capacity of fungal DNA from fungal spores captured by the wipes. Specificity, repeatability and detection limits of the qPCR procedure were tested using calibrated microbial suspensions. The feasibility and relevance of this sampling and analysis method were assessed in a 75-home pilot study. Our result showed that one specific make of wipe was more effective than the others in releasing fungal DNA. qPCR procedure showed good repeatability. The quantification limit was about 5 fg DNA/μL for all species except Penicillium chrysogenum (0.5 fg DNA/μL) and Dermatophagoïdes pteronyssinus (10 fg DNA/μL). No cross-reactivity was observed. DNA concentrations in the 53/75 homes participating in the pilot study were between 0 and 24 625, 0 and 69 738 equivalent cells per cm(2) for the fungi and bacteria, and between 0 and 1 equivalent mites per cm(2) for D. pteronyssinus. Using the SOP described, we were able to classify the 53 dwellings from the least to the most contaminated according to the quantity of DNA measured for each species. Our SOP measured fungi, bacteria and mites using a cost-efficient, discreet and well-accepted sampling method with just one qPCR tool. The whole procedure can be used for microbial analysis in large cohort studies such as the ELFE study ("Etude Longitudinale Française depuis l'Enfance") and could help improve our understanding of the interactions between the environment, allergic diseases and child development. © 2013.
Controlling droplet-transmitted respiratory infections
Hogg, William; Huston, Patricia
2006-01-01
OBJECTIVE To promote incorporation of new guidelines on control of respiratory infections into family physicians’ practices. SOURCES OF INFORMATION The World Health Organization website on pandemic influenza, the Canadian Pandemic Influenza Plan, the Ontario guidelines on respiratory infection control, and research on implementing guidelines into family practice were reviewed. We also researched and calculated what the costs of implementing the guidelines would be. MAIN MESSAGE Effective control of respiratory infections in physicians’ offices can be achieved by displaying signs in the waiting room, having reception staff give masks to patients with cough and fever, instructing these patients to clean their hands with alcohol gel and to sit at least 1 m from others, inquiring about patients’ or their close contacts’ recent travel, using disinfectant wipes to clean possibly contaminated surfaces in waiting rooms and examining areas, and having staff and care providers wear masks and wash hands or use alcohol gel. The approximate annual cost of incorporating the guidelines is about $800 per physician. CONCLUSION Because the outbreak of an influenza pandemic is likely imminent, implementing standard guidelines for control of respiratory infections in primary care offices seems wise. Following these guidelines would help prevent patients and staff from contracting serious respiratory illnesses. PMID:17279182
1988-06-01
Valve Pit Number 2 Location One near hydrazine/aerozine tank area .nd one near wastewater tank area *There is a variety of underground piping at the...loading station (wipe of drum filling nozzles/connectors) 3,475 19.u I W-1U Tank HAS-?, drain value (Tank pit valve ) <S ɘ.2 W-110 Tank HAS-I, control... valve (on top) sample bottle broken W-111 Tank Truck Station, Truck loading filler nozzle and boom sample bottle broken I/ UUMH - 1,1
Microbiological Sampling Methods and Sanitation of Edible Plants Grown on ISS
NASA Technical Reports Server (NTRS)
Parrish, Charles H. II; Khodadad, Christina L.; Garland, Nathaniel T.; Larson, Brian D.; Hummreick, Mary E.
2013-01-01
Pathogenic microbes on the surfaces of salad crops and growth chambers pose a threat to the health of crew on International Space Station. For astronauts to safely consume spacegrown vegetables produced in NASA's new vegetable production unit, VEGGIE, three technical challenges must be overcome: real-time sampling, microbiological analysis, and sanitation. Raphanus sativus cultivar Cherry Bomb II and Latuca sativa cultivar Outredgeous, two saled crops to be grown in VEGGIE, were inoculated with Salmonella enterica serovar Typhimurium (S. Typhimurium), a bacterium known to cause food-borne illness Tape- and swab-based sampling techniques were optimized for use in microgravity and assessed for effectiveness in recovery of bacteria from crop surfaces: Rapid pathogen detection and molecular analyses were performed via quantitative real-time polymerase chain reactiop using LightCycler® 480 and RAZOR® EX, a scaled-down instrument that is undergoing evaluation and testing for future flight hardware. These methods were compared with conventional, culture-based methods for the recovery of S. Typhimurium colonies. A sterile wipe saturated with a citric acid-based, food-grade sanitizer was applied to two different surface materials used in VEGGIE flight hardware that had been contaminated with the bacterium Pseudomonas aeruginosa,. another known human pathogen. To sanitize surfaces, wipes were saturated with either the sanitizer or sterile deionized water and applied to each surface. Colony forming units of P. aeruginosa grown on tryptic soy agar plates were enumerated from surface samples after sanitization treatments. Depending on the VEGGIE hardware material, 2- to 4.5-log10 reductions in colony-forming units were observed after sanitization. The difference in recovery of S. Typhimurium between tape- and swab- based sampling techniques was insignificant. RAZOR® EX rapidly detected S. Typhimurium present in both raw culture and extracted DNA samples.
Schecter, Arnold; Päpke, Olaf; Joseph, Jean Elizabeth; Tung, Kuang-Chi
2005-04-09
Polybrominated diphenyl ethers (PBDEs), a type of brominated flame retardant chemically and toxicologically similar to polychlorinated biphenyls (PCBs), are a class of emerging environmental and human contaminants. They have recently been detected in U.S. milk, blood, and food at the highest levels in the world. This pilot study was undertaken with the aim of determining levels of PBDE in the U.S. indoor environment, to assess the potential exposure to PBDEs from computer surfaces and carpets. Food of animal origin is the usual source of polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofurans (PCDF), and PCBs in humans, but there may also be environmental sources for intake of PBDEs. It was also our aim to characterize the PBDE congener profile in these indoor environmental samples. Four computer wipe samples and 9 domestic vacuum-sweeping samples were analyzed for 13 PBDE congeners, PBDEs 17 (2,2',4), 28 (2,4,4'?), 47 (2,2',4,4'?), 66 (2,3',4,4'?), 77 (3,3',4,4'?), 85 (2,2',3,4,4'?), 99 (2,2'4,4',5), 100 (2,2',4,4',6), 138 (2,2',3,4,4',5'?), 153 (2,2',4,4',5,5'?), 154 (2,2',4,4',5,6'?), 183 (2,2',3,4,4',5',6), and 209 (2,2',3,3',4,4',5,5',6,6'?). All samples tested positive for PBDEs. PBDE 209 was the dominant congener in all 4 computer wipe samples and in 7 out of the 9 vacuum dust samples. The congener profiles observed in this study varied considerably, a finding that has been observed previously. However these congener profiles differ from the pattern seen in U.S. human milk, human blood and in food, where PBDEs 47 and 99 predominate.
Mechanisms of Photo Degradation for Layered Silicate-Polycarbonate Nanocomposites
2005-09-01
crystal was used as the sampling accessory. The UV/VIS spectra were recorded using a Cary 5G UV/VIS/ near - infrared (NIR) spectrometer set to scan in...transform infrared spectroscopy. The results reveal that the carbonate linkages undergo a scission reaction upon UV exposure, thereby compromising the...were wiped clean before spectroscopic analysis. 3.3 Spectroscopic Measurements Infrared measurements were recorded on a Nicolet model 560 Magna
Environmental lead exposure risks associated with children's outdoor playgrounds.
Taylor, Mark Patrick; Camenzuli, Danielle; Kristensen, Louise Jane; Forbes, Miriam; Zahran, Sammy
2013-07-01
This study examines exposure risks associated with lead smelter emissions at children's public playgrounds in Port Pirie, South Australia. Lead and other metal values were measured in air, soil, surface dust and on pre- and post-play hand wipes. Playgrounds closest to the smelter were significantly more lead contaminated compared to those further away (t(27.545) = 3.76; p = .001). Port Pirie post-play hand wipes contained significantly higher lead loadings (maximum hand lead value of 49,432 μg/m(2)) than pre-play hand wipes (t(27) = 3.57, p = .001). A 1% increase in air lead (μg/m(3)) was related to a 0.713% increase in lead dust on play surfaces (95% CI, 0.253-1.174), and a 0.612% increase in post-play wipe lead (95% CI, 0.257-0.970). Contaminated dust from smelter emissions is determined as the source and cause of childhood lead poisoning at a rate of approximately one child every third day. Copyright © 2013 Elsevier Ltd. All rights reserved.
Beyond douching: use of feminine hygiene products and STI risk among young women.
Ott, Mary A; Ofner, Susan; Fortenberry, J Dennis
2009-05-01
Use of feminine hygiene products (feminine wipes, sprays, douches, and yeast creams) by adolescent women is common, yet understudied. We examine the association among these genital hygiene behaviors, condom use, and sexually transmitted infection (STI). Using the interview as our unit of analysis, we examined associations between genital hygiene behaviors (use of feminine wipes, feminine sprays, douches, or yeast creams), STI risk factors, and infection with Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis. We recruited 295 adolescent women from primary care clinics as part of a larger longitudinal study of STI among high-risk adolescents. Participants completed face-to-face interviews every 3 months, and provided vaginal swabs for STI testing. Data were analyzed with repeated measures logistic models to control for multiple observations contributed by each participant. Participants reported douching in 25% of interviews, feminine sprays in 29%, feminine wipes in 27%, and yeast creams in 19% of interviews. We observed a co-occurrence of douching, spraying, and wiping. A past STI (6 months or more prior) was associated with increased likelihood of yeast cream use, and a recent STI (3 months prior) was associated with increased likelihood of feminine wipe use. Condom use was modestly associated with increased likelihood of douching. Young women frequently use feminine hygiene products, and it is important for clinicians to inquire about use as these products may mimic or mask STI. We found no associations between douching and STI, but instead modest associations between hygiene and STI prevention, suggesting motivation for self-care.
Security of patient data when decommissioning ultrasound systems.
Moggridge, James
2017-02-01
Although ultrasound systems generally archive to Picture Archiving and Communication Systems (PACS), their archiving workflow typically involves storage to an internal hard disk before data are transferred onwards. Deleting records from the local system will delete entries in the database and from the file allocation table or equivalent but, as with a PC, files can be recovered. Great care is taken with disposal of media from a healthcare organisation to prevent data breaches, but ultrasound systems are routinely returned to lease companies, sold on or donated to third parties without such controls. In this project, five methods of hard disk erasure were tested on nine ultrasound systems being decommissioned: the system's own delete function; full reinstallation of system software; the manufacturer's own disk wiping service; open source disk wiping software for full and just blank space erasure. Attempts were then made to recover data using open source recovery tools. All methods deleted patient data as viewable from the ultrasound system and from browsing the disk from a PC. However, patient identifiable data (PID) could be recovered following the system's own deletion and the reinstallation methods. No PID could be recovered after using the manufacturer's wiping service or the open source wiping software. The typical method of reinstalling an ultrasound system's software may not prevent PID from being recovered. When transferring ownership, care should be taken that an ultrasound system's hard disk has been wiped to a sufficient level, particularly if the scanner is to be returned with approved parts and in a fully working state.
Planetary Protection Plan for an Antibody based instrument proposed for Mars2020
NASA Astrophysics Data System (ADS)
Smith, Heather; Parro, Víctor
The Signs Of Life Detector (SOLID) instrument is a high TRL level instrument proposed for the Mars 2020 instrument suite. In this presentation we describe the planetary protection instrument plan as if the instrument is classified as a life detection instrument compliant with Category IV(b) planetary protection mission requirements, NASA, ESA, and COSPAR policy. SOLID uses antibodies as a method for detecting organic and biomolecular components in soils. Due to the sensitive detection method, the scientific integrity of the instrument exceeds the planetary protection requirements. The instrument will be assembled and integrated in an ISO level 8 cleanroom or better (ISO 4 for the sample read out and fluidics components). Microbial reduction methods and assays employed are as follows: Wipe the outside and inside of the instrument with a mixture of isopropyl alcohol (70%) and water. Cell cultures will be the standard assay to determine enumeration of “viable” spores and other rapid assays such as LAL and ATP bioluminescence as secondary assays to verify the interior of the instrument is microbe free. SOLID’s design factors for contamination control include the following features: SOLID has the capability to heat the catchment tray to pyrolyze any Earth hitchhikers. There will also be an “air gap” of cm maintained between the sample acquisition device and the funnel inlet. This will prevent forward contamination of the sample collection device and reverse contamination of the detection unit. To mitigate false positives, SOLID will include anti-bodies for potential contaminants from organisms most commonly found in clean rooms. If selected for the Mars 2020 Rover, SOLID would be the first life detection instrument based on biomolecules sent by NASA, as such the planetary protection plan will set a precedence for future life detection instruments carrying biomolecules to other planetary bodies.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... The entire radioactive surface of the source shall be wiped with filter paper, moistened with water... shall be wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or...
Code of Federal Regulations, 2012 CFR
2012-01-01
... entire radioactive surface of the source shall be wiped with filter paper, moistened with water, with the... wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or by...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... The entire radioactive surface of the source shall be wiped with filter paper, moistened with water... shall be wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... The entire radioactive surface of the source shall be wiped with filter paper, moistened with water... shall be wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or...
USDA-ARS?s Scientific Manuscript database
Quaternary ammonium compounds, commonly referred to as quats, are cationic surfactants widely used as the active biocide ingredient for disposable disinfecting wipes. The cationic nature of quats results in a strong ionic interaction and adsorption onto wipes materials that have an anionic surface ...
Limitations of the efficacy of surface disinfection in the healthcare setting.
Williams, Gareth J; Denyer, Stephen P; Hosein, Ian K; Hill, Dylan W; Maillard, Jean-Yves
2009-06-01
We examined the efficacy of 2 commercially available wipes to effectively remove, kill, and prevent the transfer of both methicillin-resistant and methicillin-susceptible Staphylococcus aureus from contaminated surfaces. Although wipes play a role in decreasing the number of pathogenic bacteria from contaminated surfaces, they can potentially transfer bacteria to other surfaces if they are reused.
Evaluation of Firefighter Exposure to Wood Smoke during Training Exercises at Burn Houses.
Fernando, Sujan; Shaw, Lorraine; Shaw, Don; Gallea, Michael; VandenEnden, Lori; House, Ron; Verma, Dave K; Britz-McKibbin, Philip; McCarry, Brian E
2016-02-02
Smoke from wood-fueled fires is one of the most common hazards encountered by firefighters worldwide. Wood smoke is complex in nature and contains numerous compounds, including methoxyphenols (MPs) and polycyclic aromatic hydrocarbons (PAHs), some of which are carcinogenic. Chronic exposure to wood smoke can lead to adverse health outcomes, including respiratory infections, impaired lung function, cardiac infarctions, and cancers. At training exercises held in burn houses at four fire departments across Ontario, air samples, skin wipes, and urine specimens from a cohort of firefighters (n = 28) were collected prior to and after exposure. Wood was the primary fuel used in these training exercises. Air samples showed that MP concentrations were on average 5-fold greater than those of PAHs. Skin wipe samples acquired from multiple body sites of firefighters indicated whole-body smoke exposure. A suite of MPs (methyl-, ethyl-, and propylsyringol) and deconjugated PAH metabolites (hydroxynaphthalene, hydroxyfluorene, hydroxyphenanthrene, and their isomers) were found to be sensitive markers of smoke exposure in urine. Creatinine-normalized levels of these markers were significantly elevated (p < 0.05) in 24 h postexposure urine despite large between-subject variations that were dependent on the specific operational roles of firefighters while using personal protective equipment. This work offers deeper insight into potential health risk from smoke exposure that is needed for translation of better mitigation policies, including improved equipment to reduce direct skin absorption and standardized hygiene practices implemented at different regional fire services.
Beyond Douching: Use of Feminine Hygiene Products and STI Risk Among Young Women
Ott, Mary A.; Ofner, Susan; Fortenberry, J. Dennis
2010-01-01
Introduction Use of feminine hygiene products (feminine wipes, sprays, douches, and yeast creams) is common, yet understudied. Aim We examine the association among these genital hygiene behaviors, condom use, and STI. Methods We recruited 295 adolescent young women from primary care clinics as part of a larger longitudinal study of STI among high risk adolescents. Participants completed face-to-face interviews every three months, and provided vaginal swabs for STI testing. Main Outcome Measures Using the interview as our unit of analysis, we examined associations between genital hygiene behaviors (use of feminine wipes, feminine sprays, douches, or yeast creams), STI risk factors, and infection with C. trachomatis, N. gonorrhoeae, and T. vaginalis. Data were analyzed with repeated measures logistic models to control for multiple observations contributed by each participant. Results Participants reported douching in 25% of interviews, feminine sprays in 29%, feminine wipes in 27%, and yeast creams in19% of interviews. We observed a co-occurrence of douching, spraying and wiping. A past STI (6 months or more prior) was associated with increased likelihood of yeast cream use, and a recent STI (3 months prior) was associated with increased likelihood of feminine wipe use. Condom use was modestly associated with increased likelihood of douching. Conclusions Young women frequently use feminine hygiene products, and it is important for clinicians to inquire about use as these products may mimic or mask STI. We found no associations between douching and STI, but instead modest associations between hygiene and STI prevention, suggesting motivation for self-care. PMID:19170863
Security of patient data when decommissioning ultrasound systems
2017-01-01
Background Although ultrasound systems generally archive to Picture Archiving and Communication Systems (PACS), their archiving workflow typically involves storage to an internal hard disk before data are transferred onwards. Deleting records from the local system will delete entries in the database and from the file allocation table or equivalent but, as with a PC, files can be recovered. Great care is taken with disposal of media from a healthcare organisation to prevent data breaches, but ultrasound systems are routinely returned to lease companies, sold on or donated to third parties without such controls. Methods In this project, five methods of hard disk erasure were tested on nine ultrasound systems being decommissioned: the system’s own delete function; full reinstallation of system software; the manufacturer’s own disk wiping service; open source disk wiping software for full and just blank space erasure. Attempts were then made to recover data using open source recovery tools. Results All methods deleted patient data as viewable from the ultrasound system and from browsing the disk from a PC. However, patient identifiable data (PID) could be recovered following the system’s own deletion and the reinstallation methods. No PID could be recovered after using the manufacturer’s wiping service or the open source wiping software. Conclusion The typical method of reinstalling an ultrasound system’s software may not prevent PID from being recovered. When transferring ownership, care should be taken that an ultrasound system’s hard disk has been wiped to a sufficient level, particularly if the scanner is to be returned with approved parts and in a fully working state. PMID:28228821
Evaluation of residual uranium contamination in the dirt floor of an abandoned metal rolling mill.
Glassford, Eric; Spitz, Henry; Lobaugh, Megan; Spitler, Grant; Succop, Paul; Rice, Carol
2013-02-01
A single, large, bulk sample of uranium-contaminated material from the dirt floor of an abandoned metal rolling mill was separated into different types and sizes of aliquots to simulate samples that would be collected during site remediation. The facility rolled approximately 11,000 tons of hot-forged ingots of uranium metal approximately 60 y ago, and it has not been used since that time. Thirty small mass (≈ 0.7 g) and 15 large mass (≈ 70 g) samples were prepared from the heterogeneously contaminated bulk material to determine how measurements of the uranium contamination vary with sample size. Aliquots of bulk material were also resuspended in an exposure chamber to produce six samples of respirable particles that were obtained using a cascade impactor. Samples of removable surface contamination were collected by wiping 100 cm of the interior surfaces of the exposure chamber with 47-mm-diameter fiber filters. Uranium contamination in each of the samples was measured directly using high-resolution gamma ray spectrometry. As expected, results for isotopic uranium (i.e., U and U) measured with the large-mass and small-mass samples are significantly different (p < 0.001), and the coefficient of variation (COV) for the small-mass samples was greater than for the large-mass samples. The uranium isotopic concentrations measured in the air and on the wipe samples were not significantly different and were also not significantly different (p > 0.05) from results for the large- or small-mass samples. Large-mass samples are more reliable for characterizing heterogeneously distributed radiological contamination than small-mass samples since they exhibit the least variation compared to the mean. Thus, samples should be sufficiently large in mass to insure that the results are truly representative of the heterogeneously distributed uranium contamination present at the facility. Monitoring exposure of workers and the public as a result of uranium contamination resuspended during site remediation should be evaluated using samples of sufficient size and type to accommodate the heterogeneous distribution of uranium in the bulk material.
ERIC Educational Resources Information Center
Education Law Center, Inc., Newark, NJ.
In "Abbott v. Burke" the New Jersey Supreme Court determined that the state constitutional guarantee to a thorough and efficient education must include a supplemental program designed to wipe out the deficits poor children bring with them to school. In this report, the Education Law Center draws on educational research to identify the…
Forced Suffocation of Infants with Baby Wipes: A Previously Undescribed Form of Child Abuse
ERIC Educational Resources Information Center
Krugman, Scott D.; Lantz, Patrick E.; Sinal, Sara; De Jong, Allan R.; Coffman, Kathryn
2007-01-01
Background: Foreign body aspiration in children is commonly seen in emergency departments and carries a significant mortality. Abusive foreign body suffocation is not well described. Methods: We present a case-series of four infants who presented with aspiration of a baby wipe. Results: Each child was found to be a victim of child physical abuse…
Problem prevention and holistic pest management [Chapter 14
Thomas D. Landis; Tara Luna; R. Kasten Dumroese; Kim M. Wilkinson
2014-01-01
As any experienced grower knows only too well, nursery management is a continuous process of solving problems. One recurring problem is pests. In the past, nursery managers waited for an insect or disease to appear and then sprayed some toxic chemical to wipe out the pest or disease. This approach, however, also wipes out natural predators of the pest, resulting in an...
Body wiping behaviors associated with cutaneous lipids in hylid tree frogs of Florida.
Barbeau, Tamatha R; Lillywhite, Harvey B
2005-06-01
Body wiping behavior, integumentary secretions and rates of evaporative water loss (EWL) were examined in six species of Florida tree frogs (Anura: Hylidae). Additionally, morphology of the integument and dermal glands were compared among these and one other Florida tree frog (Hyla andersonii), an arid-adapted tree frog (Phyllomedusa hypochondrialis), and a highly aquatic frog (Rana utricularia). An extra-epidermal layer of lipid and mucus, presumably secreted from dermal granular glands, was detected on the skin of all Florida hylid frogs examined. Distinct body wiping behaviors were observed in the hylid frogs, but these were less complex than those described previously in phyllomedusine frogs, which occupy arid habitats, secrete lipids onto their skin, and are regarded as relatively 'waterproof'. Florida hylids occupy seasonally arid habitats and appear to have reduced rates of EWL. The suite of traits we observed in these frogs have been previously documented in a rhacophorid tree frog from seasonally arid regions of India and likely represent an evolutionary convergent response to periodic dehydration stress. The presence of lipids that are spread by simple wiping behaviors to form an extra-epidermal water barrier may represent an early stage of the more advanced adaptations described in more waterproof arboreal frogs.
Remote Wiping and Secure Deletion on Mobile Devices: A Review.
Leom, Ming Di; Choo, Kim-Kwang Raymond; Hunt, Ray
2016-11-01
Mobile devices have become ubiquitous in almost every sector of both private and commercial endeavors. As a result of such widespread use in everyday life, many users knowingly and unknowingly save significant amounts of personal and/or commercial data on these mobile devices. Thus, loss of mobile devices through accident or theft can expose users-and their businesses-to significant personal and corporate cost. To mitigate this data leakage issue, remote wiping features have been introduced to modern mobile devices. Given the destructive nature of such a feature, however, it may be subject to criminal exploitation (e.g., a criminal exploiting one or more vulnerabilities to issue a remote wiping command to the victim's device). To obtain a better understanding of remote wiping, we survey the literature, focusing on existing approaches to secure flash storage deletion and provide a critical analysis and comparison of a variety of published research in this area. In support of our analysis, we further provide prototype experimental results for three Android devices, thus providing both a theoretical and applied focus to this article as well as providing directions for further research. © 2016 American Academy of Forensic Sciences.
Methylisothiazolinone: an emergent allergen in common pediatric skin care products.
Schlichte, Megan J; Katta, Rajani
2014-01-01
Recalcitrant dermatitis, such as that of the hands, face, or genitals, may be due to allergic contact dermatitis (ACD) from ingredients in seemingly innocuous personal care products. Rising rates of allergy have been noted due to the preservative methylisothiazolinone (MI). This preservative is commonly found in skin and hair care products, especially wipes. This study evaluated the use of MI in products specifically marketed for babies and children and examined the associated marketing terms of such products. Ingredients of skin care products specifically marketed for babies and children were surveyed at two major retailers. Of 152 products surveyed, 30 products contained MI. Categories of products surveyed included facial or body wipes, antibacterial hand wipes, hair products, soaps, bubble baths, moisturizers, and sunscreens. Facial or body wipes and hair products were the categories with the greatest number of MI-containing products. MI-containing products were manufactured by a number of popular brands. Of note, products marketed as "gentle," "sensitive," "organic," or "hypoallergenic" often contained MI, thus emphasizing the importance of consumer scrutiny of product choices. These findings reinforce the importance of educating parents and providing consumer decision-making advice regarding common skin care products, in order to help prevent ACD in children.
Hyder, O
2012-07-01
Stethoscope diaphragms are frequently colonized by bacteria. This cross-sectional study described the frequency and factors associated with reporting ever cleaning stethoscopes among 408 medical students and doctors at a medical college and 2 teaching hospitals in Rawalpindi, Pakistan. A minority of the respondents (37.7%) reported having ever cleaned their stethoscope. Following normal clinical use, wiping with a dry cloth was the most frequently reported method of cleaning (53.2%). After contamination of the diaphragm with blood or secretions, cleaning with an alcoholic swab was the most common method (64.3%). In univariate and multivariate analyses, history of receiving information on stethoscope cleaning, utilization of personal stethoscope at last use and affiliation with internal medicine department were factors strongly associated with ever cleaning of stethoscope. Future research for improving stethoscope cleaning practices should explore educational interventions aimed at health care professionals.
Modelling of influential parameters on a continuous evaporation process by Doehlert shells
Porte, Catherine; Havet, Jean-Louis; Daguet, David
2003-01-01
The modelling of the parameters that influence the continuous evaporation of an alcoholic extract was considered using Doehlert matrices. The work was performed with a wiped falling film evaporator that allowed us to study the influence of the pressure, temperature, feed flow and dry matter of the feed solution on the dry matter contents of the resulting concentrate, and the productivity of the process. The Doehlert shells were used to model the influential parameters. The pattern obtained from the experimental results was checked allowing for some dysfunction in the unit. The evaporator was modified and a new model applied; the experimental results were then in agreement with the equations. The model was finally determined and successfully checked in order to obtain an 8% dry matter concentrate with the best productivity; the results fit in with the industrial constraints of subsequent processes. PMID:18924887
A cultural look at moral purity: wiping the face clean
Lee, Spike W. S.; Tang, Honghong; Wan, Jing; Mai, Xiaoqin; Liu, Chao
2015-01-01
Morality is associated with bodily purity in the custom of many societies. Does that imply moral purity is a universal psychological phenomenon? Empirically, it has never been examined, as all prior experimental data came from Western samples. Theoretically, we suggest the answer is not so straightforward—it depends on the kind of universality under consideration. Combining perspectives from cultural psychology and embodiment, we predict a culture-specific form of moral purification. Specifically, given East Asians' emphasis on the face as a representation of public self-image, we hypothesize that facial purification should have particularly potent moral effects in a face culture. Data show that face-cleaning (but not hands-cleaning) reduces guilt and regret most effectively against a salient East Asian cultural background. It frees East Asians from guilt-driven prosocial behavior. In the wake of their immorality, they find a face-cleaning product especially appealing and spontaneously choose to wipe their face clean. These patterns highlight both culturally variable and universal aspects of moral purification. They further suggest an organizing principle that informs the vigorous debate between embodied and amodal perspectives. PMID:26029134
Analysis of Nonvolatile Residue (NVR) from Spacecraft Systems
NASA Technical Reports Server (NTRS)
Colony, J. A.
1985-01-01
Organic contamination on critical spacecraft surfaces can cause electronic problems, serious attenuation of various optical signals, thermal control changes, and adhesion problems. Such contaminants can be detected early by the controlled use of witness mirrors, witness plates, wipe sampling, or direct solvent extraction. Each method requires careful control of variables of technique and materials to attain the ultimate sensitivities inherent to that procedure. Subsequent chemical analysis of the contaminant sample by infrared and mass spectrometry identifies the components, gives semiquantitative estimates of contaminant thickness, indicates possible sources of the nonvolatile residue (NVR), and provides guidance for effective cleanup procedures.
Moore, John E; Watabe, Miyuki; Stewart, Andrew; Cherie Millar, B; Rao, Juluri R
2009-01-01
Maturing compost heaps normally attaining temperatures ranging from 55 to 65 degrees C is generally regarded to conform to recommended biological risks and sanitation standards for composts stipulated by either EU or US-EPA. Composted products derived from animal sources are further required by EU biohazard safety regulatory legislation that such composts either attain 70 degrees C for over 3h during maturation or via treatment at 70 degrees C for 1h before being considered for dispensation on land. The setting of the upper limit of thermal lethality at 70 degrees C/1h for achieving biosecurity of the animal waste composted products (e.g. pelleted fertilizer formulations) is not properly substantiated by specific validation tests, comprising a 'wipe-out' step (usually via autoclaving) followed by inoculation of a prescribed bacterium, exposure to 70 degrees C/1h and the lethality determined. Pelleted formulations of composts are not amenable for wet methods (autoclaving) for wipe-out sterilization step as this is detrimental to the pellet and compromises sample integrity. This study describes a laboratory method involving the employment of ((60)Co) irradiation 'wipe-out' step to: (a) compost sub-samples drawn from compost formulation heaps and (b) pelleted products derived from composted animal products while determining the thermal lethality of a given time/temperature (70 degrees C/1h) treatment process and by challenging the irradiated sample (not just with one bacterium but), out with 10 potential food-poisoning organisms from the bacterial genera (Campylobacter, Escherichia, Listeria, Salmonella, Yersinia) frequently detected in pig and poultry farm wastes. This challenge test on compost sub-samples can be a useful intervention ploy for 'inspection and validation' technique for composters during the compost maturity process, whose attainment of temperatures of 55-65 degrees C is presumed sufficient for attainment of sanitation. Stringent measures are further required by law for composted products arising from rural industrialists producing pelleted fertilizers from re-composted animal agriculture wastes comprising pig slurry solids, poultry litter and spent mushroom compost, which carry residual food-borne pathogens with implications to the food chain including humans. Environmentally, sustainable means of recycling farm wastes require that final composted products are free of pathogens in compliance with environmental safety legislation before their release to the market. This test developed provides a science-based risk characterization tool for sustainably managing environmental safety by 'validating' thermal lethality of a given composting process or their derivatives achieved without compromising the sample integrity or ambiguity attached to microbiological validation involving steam sterilization or autoclaving procedures and helps audit the resurgent bacterial populations from surviving non-pathogenic organisms in the end-products of animal waste compost formulations.
[Biomechanical characteristics of the wiping reflex cycle].
Berkinblit, M B; Zharkova, I S; Fel'dman, A G; Fukson, O I
1984-01-01
Multijoint goal-directed hindlimb movements in response to chemical stimulation delivered to different skin sites on the medial back surface (wiping reflex-WR) were filmed and analysed in spinal or intact frogs Rana temporaria. Each WR cycle was divisible into five phases (flexion, lifting, aiming, wiping and extension) usually separated from each other by postural interruptions. One or several of the phases might spontaneously be reduced or deleted at all (e. g. the extension phase), although the WR was still effective. Such a reduction was, as a rule, observed in intact frogs while spinal ones usually exhibited the maximum phase sequence. It is suggested that the central spinal generator of the WR is formed of separate functional blocks each of which specifies a certain interjoint coordination and brings the joints to the central-conditioned equilibrium positions.
Corp, Nadia; Hayaki, Hitoshige; Matsusaka, Takahisa; Fujita, Shiho; Hosaka, Kazuhiko; Kutsukake, Nobuyuki; Nakamura, Michio; Nakamura, Miho; Nishie, Hitonaru; Shimada, Masaki; Zamma, Koichiro; Wallauer, William; Nishida, Toshisada
2009-04-01
In 1998, four chimpanzees in the Mahale Mountains National Park, Tanzania, were observed wiping their mouths with non-detached leaves or stalks of grass, or rubbing their mouths with a tree trunk or branch, especially while eating lemons. The number of mouth-wiping/rubbing individuals increased to 18 in 1999. By 2005, 29 chimpanzees were documented wiping/rubbing their muzzles in this way. Although it is difficult to determine whether the chimpanzees acquired this behavior as a result of trial and error or social learning, the fact that chimpanzees at other sites perform this behavior with detached leaves or leafy twigs much more often than with intact items suggests the possibility that cleaning with intact plant parts at Mahale spread via social learning.
Flame retardant exposure assessment: findings from a behavioral intervention study.
Gibson, Elizabeth A; Stapleton, Heather M; Calero, Lehyla; Holmes, Darrell; Burke, Kimberly; Martinez, Rodney; Cortes, Boris; Nematollahi, Amy; Evans, David; Herbstman, Julie B
2018-06-28
Polybrominated diphenyl ethers (PBDEs) have been largely replaced by organophosphate flame retardants (OPFRs) and alternative brominated flame retardants (Alt-BFRs) to meet flammability requirements. Humans are ubiquitously exposed to some variety of flame retardants through contact with consumer products directly or through household dust. To evaluate the effectiveness of house cleaning and hand washing practices to reduce exposure to flame retardants, we measured concentrations in dermal hand wipes and urinary metabolites before and after assignment to two consecutive interventions. We selected 32 mother and child dyads from an existing cohort. This analysis focuses on mothers. Participants provided baseline measurements (urine, hand wipes, and questionnaires) and were then assigned for 1 week to either a house cleaning (including instruction on proper technique and cleaning supplies) or hand washing (including instruction on proper technique and soaps) intervention arm. For the second week, participants were assigned to the second intervention in addition to their initial assignment, thus all subjects both washed their hands and cleaned according to the intervention guidelines during week 2. We collected measurements at the end of weeks 1 and 2. We found reductions in urinary analytes after week 1 of house cleaning (BCIPHIPP and ip-DPHP), week 1 of hand washing (BCIPP, BCIPHIPP, and tbutyl-DPHP), and week 2 of combined interventions (BCIPHIPP and tbutyl-DPHP), compare to baseline. We found no significant decline in hand wipes in the entire sample but did find reductions after week 1 of house cleaning (BDE 209), week 1 of hand washing (TCEP), and week 2 of combined interventions (TDCIPP and BDE 209) in women with exposure above the median at baseline (verified through simulations). Exposure to individual flame retardants was reduced by about half, in some cases, by 1 week of increased hand washing, house cleaning to reduce dust, or combined activities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2012 CFR
2012-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2013 CFR
2013-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2010 CFR
2010-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2011 CFR
2011-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Nonvolatile and Cryogenic-compatible Quantum Memory Devices (QuMEM)
2016-06-01
construction including: • 4” SiO2 /Si substrates and wafer/sample holders • Tweezers and wafer scribe • Safety glasses , gloves, and fab wipes • Probe tips...Cleaving of NbSe2 with Scotch™ Tape method ............................................................ 56 59. Transfer of NbSe2 atomic crystals to SiO2 ...O2 plasma + optional CF4 5 Top superconductor electrode evaporation Thermal Evaporation at SDSU MEMS Lab P+ Si Handle Wafer SiO2 (Oxide
Nonvolatile and Cryogenic-Compatible Quantum Memory Devices (QuMEM)
2016-06-01
construction including: • 4” SiO2 /Si substrates and wafer/sample holders • Tweezers and wafer scribe • Safety glasses , gloves, and fab wipes • Probe tips...Cleaving of NbSe2 with Scotch™ Tape method ............................................................ 56 59. Transfer of NbSe2 atomic crystals to SiO2 ...O2 plasma + optional CF4 5 Top superconductor electrode evaporation Thermal Evaporation at SDSU MEMS Lab P+ Si Handle Wafer SiO2 (Oxide
Persson, Josefin; Wang, Thanh; Hagberg, Jessika
2018-07-01
The construction of extremely airtight and energy efficient low-energy buildings is achieved by using functional building materials, such as age-resistant plastics, insulation, adhesives, and sealants. Additives such as organophosphate flame retardants (OPFRs) can be added to some of these building materials as flame retardants and plasticizers. Some OPFRs are considered persistent, bioaccumulative and toxic. Therefore, in this pilot study, the occurrence and distribution of nine OPFRs were determined for dust, air, and window wipe samples collected in newly built low-energy preschools with and without environmental certifications. Tris(1,3-dichloroisopropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) were detected in all indoor dust samples at concentrations ranging from 0.014 to 10μg/g and 0.0069 to 79μg/g, respectively. Only six OPFRs (predominantly chlorinated OPFRs) were detected in the indoor air. All nine OPFRs were found on the window surfaces and the highest concentrations, which occurred in the reference preschool, were measured for 2-ethylhexyl diphenyl phosphate (EHDPP) (maximum concentration: 1500ng/m 2 ). Interestingly, the OPFR levels in the environmental certified low-energy preschools were lower than those in the reference preschool and the non-certified low-energy preschool, probably attributed to the usage of environmental friendly and low-emitting building materials, interior decorations, and consumer products. Copyright © 2018 Elsevier B.V. All rights reserved.
Estimating Dermal Transfer of Copper Particles from the ...
Lumber pressure-treated with micronized copper was examined for the release of copper and copper micro/nanoparticles using a surface wipe method to simulate dermal transfer. In 2003, the wood industry began replacing CCA treated lumber products for residential use with copper based formulations. Micronized copper (nano to micron sized particles) has become the preferred treatment formulation. There is a lack of information on the release of copper, the fate of the particles during dermal contact, and the copper exposure level to children from hand-to-mouth transfer. For the current study, three treated lumber products, two micronized copper and one ionic copper, were purchased from commercial retailers. The boards were left to weather outdoors for approximately 1 year. Over the year time period, hand wipe samples were collected periodically to determine copper transfer from the wood surfaces. The two micronized formulations and the ionic formulation released similar levels of total copper. The amount of copper released was high initially, but decreased to a constant level (~1.5 mg m-2) after the first month of outdoor exposure. Copper particles were identified on the sampling cloths during the first two months of the experiment, after which the levels of copper were insufficient to collect interpretable data. After 1 month, the particles exhibited minimal changes in shape and size. At the end of 2-months, significant deterioration of the particles was
Rodrigues, Ema G.; Virji, M. Abbas; McClean, Michael D.; Weinberg, Janice; Woskie, Susan; Pepper, Lewis D.
2009-01-01
Bridge painters are exposed to lead during several job tasks performed during the workday, such as sanding, scraping, and blasting. After the Occupational Safety and Health Administration standard was passed in 1993 to control lead exposures among construction workers including bridge painters, this study was conducted among 84 bridge painters in the New England area to determine the significant predictors of blood lead levels. Lead was measured in personal air and hand wipe samples that were collected during the 2-week study period and in blood samples that were collected at the beginning and at the end of the study period. The personal air and hand wipe data as well as personal behaviors (i.e., smoking, washing, wearing a respirator) and work site conditions were analyzed as potential determinants of blood lead levels using linear mixed effects models. Our results show that the mean air lead levels over the 2-week period were the most predictive exposure measure of blood lead levels. Other individual-level significant predictors of blood lead levels included months worked on bridge painting crews, education, and personal hygiene index. Of the site-level variables investigated, having a containment facility on site was a significant predictor of blood lead levels. Our results also indicate that hand wipe lead levels were significantly associated with higher blood lead levels at the end of the study period compared with the beginning of the study period. Similarly, smoking on site and respirator fit testing were significantly associated with higher blood lead levels at the end of the study period. This study shows that several individual-level and site-level factors are associated with blood lead levels among bridge painters, including lead exposure through inhalation and possible hand-to-mouth contact, personal behaviors such as smoking on site, respirator fit testing, and work site conditions such as the use of better containment facilities. Accordingly, reduction in blood lead levels among bridge painters can be achieved by improving these workplace practices. PMID:19953411
Methylisothiazolinone: An Emergent Allergen in Common Pediatric Skin Care Products
Schlichte, Megan J.
2014-01-01
Recalcitrant dermatitis, such as that of the hands, face, or genitals, may be due to allergic contact dermatitis (ACD) from ingredients in seemingly innocuous personal care products. Rising rates of allergy have been noted due to the preservative methylisothiazolinone (MI). This preservative is commonly found in skin and hair care products, especially wipes. This study evaluated the use of MI in products specifically marketed for babies and children and examined the associated marketing terms of such products. Ingredients of skin care products specifically marketed for babies and children were surveyed at two major retailers. Of 152 products surveyed, 30 products contained MI. Categories of products surveyed included facial or body wipes, antibacterial hand wipes, hair products, soaps, bubble baths, moisturizers, and sunscreens. Facial or body wipes and hair products were the categories with the greatest number of MI-containing products. MI-containing products were manufactured by a number of popular brands. Of note, products marketed as “gentle,” “sensitive,” “organic,” or “hypoallergenic” often contained MI, thus emphasizing the importance of consumer scrutiny of product choices. These findings reinforce the importance of educating parents and providing consumer decision-making advice regarding common skin care products, in order to help prevent ACD in children. PMID:25342949
Disinfection of Tonometers: A Report by the American Academy of Ophthalmology.
Junk, Anna K; Chen, Philip P; Lin, Shan C; Nouri-Mahdavi, Kouros; Radhakrishnan, Sunita; Singh, Kuldev; Chen, Teresa C
2017-12-01
To examine the efficacy of various disinfection methods for reusable tonometer prisms in eye care and to highlight how disinfectants can damage tonometer tips and cause subsequent patient harm. Literature searches were conducted last in October 2016 in the PubMed and the Cochrane Library databases for original research investigations. Reviews, non-English language articles, nonophthalmology articles, surveys, and case reports were excluded. The searches initially yielded 64 unique citations. After exclusion criteria were applied, 10 laboratory studies remained for this review. Nine of the 10 studies used tonometer prisms and 1 used steel discs. The infectious agents covered in this assessment include adenovirus 8 and 19, herpes simplex virus (HSV) 1 and 2, human immunodeficiency virus 1, hepatitis C virus, enterovirus 70, and variant Creutzfeldt-Jakob disease. All 4 studies of adenovirus 8 concluded that after sodium hypochlorite (dilute bleach) disinfection, the virus was undetectable, but only 2 of the 4 studies found that 70% isopropyl alcohol (e.g., alcohol wipes or soaks) eradicated all viable virus. All 3 HSV studies concluded that both sodium hypochlorite and 70% isopropyl alcohol eliminated HSV. Ethanol, 70% isopropyl alcohol, dilute bleach, and mechanical cleaning all lack the ability to remove cellular debris completely, which is necessary to prevent prion transmission. Therefore, single-use tonometer tips or disposable tonometer covers should be considered when treating patients with suspected prion disease. Damage to tonometer prisms can be caused by sodium hypochlorite, 70% isopropyl alcohol, 3% hydrogen peroxide, ethyl alcohol, water immersion, ultraviolet light, and heat exposure. Disinfectants can cause tonometer tips to swell and crack by dissolving the glue that holds the hollow tip together. The tonometer tip cracks can irritate the cornea, harbor microbes, or allow disinfectants to enter the interior of the tonometer tip. Sodium hypochlorite (dilute bleach) offers effective disinfection against adenovirus and HSV, the viruses commonly associated with nosocomial outbreaks in eye care. Tonometer prisms should be examined regularly for signs of damage. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Waste Management System overview for future spacecraft.
NASA Technical Reports Server (NTRS)
Ingelfinger, A. L.; Murray, R. W.
1973-01-01
Waste Management Systems (WMS) for post Apollo spacecraft will be significantly more sophisticated and earthlike in user procedures. Some of the features of the advanced WMS will be accommodation of both males and females, automatic operation, either tissue wipe or anal wash, measurement and sampling of urine, feces and vomitus for medical analysis, water recovery, and solids disposal. This paper presents an overview of the major problems of and approaches to waste management for future spacecraft. Some of the processes discussed are liquid/gas separation, the Dry-John, the Hydro-John, automated sampling, vapor compression distillation, vacuum distillation-catalytic oxidation, incineration, and the integration of the above into complete systems.
Cleaning of Filtering Facepiece Respirators Contaminated with Mucin and Staphylococcus aureus
2012-11-01
Journal of Infection Control. Document contains color images. Decontamination and reuse of filtering facepiece respirators (FFRs) has been proposed to...in the area of cleaning FFRs. This study evaluates the cleaning of three surgical N95 FFRs by three commercial wipe products as an initial exploration...significantly higher penetration than the other wipe products. The significance of these data to the concept of decontamination and reuse of FFRs will remain
Improving efficiency, reducing infection, and enhancing experience.
Massa, Judith
For health professionals to make an informed choice and tailor each bed bath to the individual needs of the patient, they must firstly understand the different bed bath options available, their impact on skin integrity, and any associated risks they may pose to the patient in terms of cross-infection. Only with this knowledge can health professionals determine the appropriate form and frequency of the bed bath. Specialist wipes offer significant improvements in skin care and a reduced risk of cross-infection, compared with the traditional soap and water bed bath. Use of these wipes also improves the efficiency of the process, which links to the Productive Ward Initiative and results in clinical staff (i.e. nursing staff, healthcare assistants) having more time available to undertake additional patient care activities. This product focus highlights the benefits of moving to a wipe-based bed bath method, and the significant efficiency savings that can be realized as a result.
Environmentally compatible hand wipe cleaning solvents
NASA Technical Reports Server (NTRS)
Clayton, Catherine P.; Kovach, Michael P.
1995-01-01
Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.
Biomarkers of mercury exposure in two eastern Ukraine cities
Gibb, H.; Haver, C.; Kozlov, K.; Centeno, J.A.; Jurgenson, V.; Kolker, A.; Conko, K.M.; Landa, E.R.; Xu, H.
2011-01-01
This study evaluates biomarkers of mercury exposure among residents of Horlivka, a city in eastern Ukraine located in an area with geologic and industrial sources of environmental mercury, and residents of Artemivsk, a nearby comparison city outside the mercury-enriched area. Samples of urine, blood, hair, and nails were collected from study participants, and a questionnaire was administered to obtain data on age, gender, occupational history, smoking, alcohol consumption, fish consumption, tattoos, dental amalgams, home heating system, education, source of drinking water, and family employment in mines. Median biomarker mercury concentrations in Artemivsk were 0.26 ??g/g-Cr (urine), 0.92 ??g/L (blood), 0.42 ??g/g (hair), 0.11 ??g/g (toenails), and 0.09 ??g/g (fingernails); median concentrations in Horlivka were 0.15 ??g/g-Cr (urine), 1.01 ??g/L (blood), 0.14 ??g/g (hair), 0.31 ??g/g (toenails), and 0.31 ??g/g (fingernails). Biomarkers of mercury exposure for study participants from Horlivka and Artemivsk are low in comparison with occupationally exposed workers at a mercury recycling facility in Horlivka and in comparison with exposures known to be associated with clinical effects. Blood and urinary mercury did not suggest a higher mercury exposure among Horlivka residents as compared with Artemivsk; however, three individuals living in the immediate vicinity of the mercury mines had elevated blood and urinary mercury, relative to overall results for either city. For a limited number of residents from Horlivka (N = 7) and Artemivsk (N = 4), environmental samples (vacuum cleaner dust, dust wipes, soil) were collected from their residences. Mercury concentrations in vacuum cleaner dust and soil were good predictors of blood and urinary mercury. Copyright ?? 2011 JOEH, LLC.
Engelhart, Steffen; Exner, Martin; Simon, Arne
2015-01-01
This in vitro study investigated the external disinfection of two needle-free connection devices (NFC) using Octeniderm® (spraying and wiping technique) vs. Descoderm® pads (wiping technique). The split-septum membrane of the NFC was contaminated with >105 CFU K. pneumoniae or S. epidermidis. The efficacy of the disinfection at 30 sec. exposure time was controlled by taking a swab sample and by flushing the NFC with sterile 0.9% sodium chloride solution. Disinfection with octenidine dihydrochloride 0.1 g, 1-Propanol 30.0 g, and 2-Propanol 45.0 g in 100 g solution was highly effective (CFU reduction ≥4 log) against both microorganisms, whereas the use of 63.1 g 2-Propanol in 100 ml solution led to residual contamination with S. epidermidis. Our investigation underlines that (i) in clinical practice disinfection of NFCs before use is mandatory, and that (ii) details of disinfection technique are of utmost importance regarding their efficacy. Our investigation revealed no significant differences between both split-septum NFC types. Clinical studies are needed to confirm a possible superiority of disinfectants with long-lasting residual antimicrobial activity. PMID:26693394
NASA Technical Reports Server (NTRS)
Gallagher, R. Scott; Purvis, John A.; Moran, Wade W.
1995-01-01
Engineers at Hercules Aerospace, a rocket motor manufacturer in Utah, have worked closely with chemists at Glidco Organics to study the feasibility of using terpenes for zero-residue wipe cleaning. The result of this work is a technological breakthrough, in which the barrier to ultra-low non-volatile residue formation has been broken. After 2 years of development and testing, SCM Glidco Organics has announced the availability of Glidsafe(registered trademark) Prepsolv(TM): a state-of-the-art ultra-low residue terpene wipe cleaning agent that does not require rinsing. Prepsolv(TM) can successfully be used in simple hand-wipe cleaning processes without fear of leaving surface residues. Industry testing has confirmed that Prepsolv(TM) is not only highly effective, but can even be less expensive to use than traditional cleaning solvents like methyl chloroform. This paper addresses the features and benefits of Prepsolv(TM), and presents performance and material compatibility data that characterizes this unique cleaning agent. Since its commercialization, Hercules Aerospace has chosen Prepsolv(TM) as the optimum cleaning agent to replace ozone-depleting solvents in their weapons factory in Magna, UT. Likewise, Boeing has approved Prepsolv(TM) for cleaning components in the manufacture of commercial aircraft at their facilities in Seattle, WA and Wichita, KS. Additional approvals are forthcoming for this uniquely safe and effective solvent.
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szrom, Fran; Falo, Gerald A.; Lodde, Gordon M.
2009-03-01
Depleted uranium (DU) intake rates and subsequent dose rates were estimated for personnel entering armored combat vehicles perforated with DU penetrators (level II and level III personnel) using data generated during the Capstone Depleted Uranium (DU) Aerosol Study. Inhalation intake rates and associated dose rates were estimated from cascade impactors worn by sample recovery personnel and from cascade impactors that served as area monitors. Ingestion intake rates and associated dose rates were estimated from cotton gloves worn by sample recovery personnel and from wipe test samples from the interior of vehicles perforated with large caliber DU munitions. The mean DUmore » inhalation intake rate for level II personnel ranged from 0.447 mg h-1 based on breathing zone monitor data (in and around a perforated vehicle) to 14.5 mg h-1 based on area monitor data (in a perforated vehicle). The mean DU ingestion intake rate for level II ranged from 4.8 mg h-1 to 38.9 mg h-1 based on the wipe test data including surface to glove transfer factors derived from the Capstone data. Based on glove contamination data, the mean DU ingestion intake rates for level II and level III personnel were 10.6 mg h-1 was and 1.78 mg h-1, respectively. Effective dose rates and peak kidney uranium concentration rates were calculated based on the intake rates. The peak kidney uranium concentration rate cannot be multiplied by the total exposure duration when multiple intakes occur because uranium will clear from the kidney between the exposures.« less
Probst, Alexander; Facius, Rainer; Wirth, Reinhard; Wolf, Marco; Moissl-Eichinger, Christine
2011-01-01
Microbial contaminants on spacecraft can threaten the scientific integrity of space missions due to probable interference with life detection experiments. Therefore, space agencies measure the cultivable spore load (“bioburden”) of a spacecraft. A recent study has reported an insufficient recovery of Bacillus atrophaeus spores from Vectran fabric, a typical spacecraft airbag material (A. Probst, R. Facius, R. Wirth, and C. Moissl-Eichinger, Appl. Environ. Microbiol. 76:5148-5158, 2010). Here, 10 different sampling methods were compared for B. atrophaeus spore recovery from this rough textile, revealing significantly different efficiencies (0.5 to 15.4%). The most efficient method, based on the wipe-rinse technique (foam-spatula protocol; 13.2% efficiency), was then compared to the current European Space Agency (ESA) standard wipe assay in sampling four different kinds of spacecraft-related surfaces. Results indicate that the novel protocol out-performed the standard method with an average efficiency of 41.1% compared to 13.9% for the standard method. Additional experiments were performed by sampling Vectran fabric seeded with seven different spore concentrations and five different Bacillus species (B. atrophaeus, B. anthracis Sterne, B. megaterium, B. thuringiensis, and B. safensis). Among these, B. atrophaeus spores were recovered with the highest (13.2%) efficiency and B. anthracis Sterne spores were recovered with the lowest (0.3%) efficiency. Different inoculation methods of seeding spores on test surfaces (spotting and aerosolization) resulted in different spore recovery efficiencies. The results of this study provide a step forward in understanding the spore distribution on and recovery from rough surfaces. The results presented will contribute relevant knowledge to the fields of astrobiology and B. anthracis research. PMID:21216908
Bliss, Nola; Stull, Jason W; Moeller, Steven J; Rajala-Schultz, Päivi J; Bowman, Andrew S
2017-09-15
OBJECTIVE To identify the geographic distribution of exhibition swine in the Midwestern United States, characterize management practices used for exhibition swine, and identify associations between those practices and influenza A virus (IAV) detection in exhibition swine arriving at county or state agricultural fairs. DESIGN Cross-sectional survey. SAMPLE 480 swine exhibitors and 641 exhibition swine. PROCEDURES Inventories of swine exhibited at fairs in 6 selected Midwestern states during 2013 and of the total swine population (including commercial swine) in these regions in 2012 were obtained and mapped. In 2014, snout wipe samples were collected from swine on arrival at 9 selected fairs in Indiana (n = 5) and Ohio (4) and tested for the presence of IAV. Also at fair arrival, swine exhibitors completed a survey regarding swine management practices. RESULTS Contrary to the total swine population, the exhibition swine population was heavily concentrated in Indiana and Ohio. Many swine exhibitors reported attending multiple exhibitions within a season (median number, 2; range, 0 to 50), with exhibited swine often returned to their farm of origin. Rearing of commercial and exhibition swine on the same premises was reported by 13.3% (56/422) of exhibitors. Hosting an on-farm open house or sale was associated with an increased odds of IAV detection in snout wipe samples. CONCLUSIONS AND CLINICAL RELEVANCE The exhibition swine population was highly variable and differed from the commercial swine population in terms of pig density across geographic locations, population integrity, and on-farm management practices. Exhibition swine may be important in IAV transmission, and identified biosecurity deficiencies may have important public and animal health consequences.
Tang, Patrick H P; Worster, Andrew; Srigley, Jocelyn A; Main, Cheryl L
2011-07-01
The objective of this study was to determine the prevalence of Staphylococcus-contaminated stethoscopes belonging to emergency department (ED) staff and to identify the proportion of these that were Staphylococcus aureus or methicillin-resistant Staphylococcus aureus (MRSA). We conducted a prospective observational cohort study of bacterial cultures from 100 ED staff members' stethoscopes at three EDs. Study participants were asked to complete a questionnaire. Fifty-four specimens grew coagulase-negative staphylococci and one grew methicillin-susceptible S. aureus. No MRSA was cultured. Only 8% of participants, all of whom were nurses, reported cleaning their stethoscope before or after each patient assessment. Alcohol-based wipes were most commonly used to clean stethoscopes. A lack of time, being too busy, and forgetfulness were the most frequently reported reasons for not cleaning the stethoscope in the ED. This study indicates that although stethoscope contamination rates in these EDs are high, the prevalence of S. aureus or MRSA on stethoscopes is low.
In-injection port thermal desorption for explosives trace evidence analysis.
Sigman, M E; Ma, C Y
1999-10-01
A gas chromatographic method utilizing thermal desorption of a dry surface wipe for the analysis of explosives trace chemical evidence has been developed and validated using electron capture and negative ion chemical ionization mass spectrometric detection. Thermal desorption was performed within a split/splitless injection port with minimal instrument modification. Surface-abraded Teflon tubing provided the solid support for sample collection and desorption. Performance was characterized by desorption efficiency, reproducibility, linearity of the calibration, and method detection and quantitation limits. Method validation was performed with a series of dinitrotoluenes, trinitrotoluene, two nitroester explosives, and one nitramine explosive. The method was applied to the sampling of a single piece of debris from an explosion containing trinitrotoluene.
Characterizing the recovery of a solid surface after tungsten nano-tendril formation
NASA Astrophysics Data System (ADS)
Wright, G. M.; van Eden, G. G.; Kesler, L. A.; De Temmerman, G.; Whyte, D. G.; Woller, K. B.
2015-08-01
Recovery of a flat tungsten surface from a nano-tendril surface is attempted through three techniques; a mechanical wipe, a 1673 K annealing, and laser-induced thermal transients. Results were determined through SEM imaging and elastic recoil detection to assess the helium content in the surface. The mechanical wipe leaves a ∼0.5 μm deep layer of nano-tendrils on the surface post-wipe regardless of the initial nano-tendril layer depth. Laser-induced thermal transients only significantly impact the surface morphology at heat loads of 35.2 MJ/m2 s1/2 or above, however a fully flat or recovered surface was not achieved for 100 transients at this heat load despite reducing the helium content by a factor of ∼7. A 1673 K annealing removes all detectable levels of helium but sub-surface voids/bubbles remain intact. The surface is recovered to a nearly flat state with only some remnants of nano-tendrils re-integrating into the surface remaining.
Results of Testing the Relative Oxidizing Hazard of Wipes and KMI Zeolite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ams, Bridget Elaine
This report includes the results from testing performed on the relative oxidizing hazard of a number of organic sorbing wipe materials, as well as KMI zeolite. These studies were undertaken to address a need by the Los Alamos National Laboratory (LANL) Hazardous Materials Management group, which requires a material that can sorb small spills in a glovebox without creating a disposal hazard due to the potential for oxidation reactions, as requested in Request for Testing of Wipes and Zeolite for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-002) and Request for Testing of Chamois Material for Los Alamos Nationalmore » Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-005). This set oftests is a continuation of previous testing described in Results from Preparation and Testing of Sorbents Mixed with (DWT-RPT-003), which provided data for the Waste Isolation Pilot Plant's Basis of Knowledge. The Basis of Knowledge establishes criteria for evaluating transuranic (TRU) waste that contains oxidizing chemicals.« less
NASA Technical Reports Server (NTRS)
Brown, Patricia A.; Comparin, Jeffrey H.
1995-01-01
Clandestine methamphetamine laboratories are prevalent in southern California. The most common encountered synthesis results in vapor release, and drug residue being left behind. The suspected manufacturing area can be vacuumed and/or methanol wiped and screened immediately at the lab site using the Ionscan. Positive results are confirmed by obtaining vacuum sweep samples with subsequent analysis at the DEA Laboratory. This procedure has been utilized successfully for identifying methamphetamine and ephedrine from clandestine laboratories that have been abandoned and/or remodeled.
Chen, Yi-Hao; Wu, Pei-Chang; Shiea, Jentaie; Lo, Li-Hua; Wu, Yi-Chen; Kuo, Hsi-Kung
2009-02-01
The aim of this study was to determine the sterility, stability, and efficacy of a commercially available brand of bevacizumab for 6 months of being stored in multidose vials at 4 degrees C. Bevacizumab was aseptically and repeatedly drawn four to five times from new vials into syringes for clinical use within the first month; the remaining bevacizumab was left in the vials and refrigerated at 4 degrees C for 0, 1, 3, and 6 months for research. Each time before bevacizumab was withdrawn and every weekend when it was not sampled, the rubber top of each vial was disinfected by using 10% povidone-iodine solution and an isopropyl alcohol wipe. Each vial had been sampled for less than 12 times during the experimental periods. All vials were analyzed for microbial growth. The stability of bevacizumab was analyzed by MALDI-TOF MS (matrix-assisted laser desorption ionization/time-of-flight mass spectrometry). The efficacy of bevacizumab was analyzed by enzyme-linked immunosorbent assay (ELISA). At each time period, bevacizumab was mixed with vascular endothelial growth factor (VEGF)-165 and left undisturbed for 3 h. The efficacy of bevacizumab was then evaluated by measuring the concentration of residual-free VEGF-165. No microbial growth was obtained from any of the bevacizumab samples during each time period, indicating that the bevacizumab stored at 4 degrees C after the vials had been pierced remained sterile. MALDI-TOF MS analysis revealed that the 1-, 3-, and 6-month samples were stable, and there were no molecular-weight changes among any of the samples. The level of degradation of bevacizumab at 1, 3, and 6 months was compared with that of the control (0 months). The results of ELISA showed less than 10% degradation at all time periods. This study suggests that if aseptic precautions are followed while using bevacizumab, the contents of multiple-dose vials stored at 4 degrees C will remain sterile. The anti-VEGF activity of bevacizumab stored at 4 degrees C will remain stable for up to 6 months.
Code of Federal Regulations, 2010 CFR
2010-04-01
... fuel alcohol for testing and analysis. Samples of spirits may not be removed from the premises of the alcohol fuel plant. Samples of fuel alcohol may be removed from the premises of the alcohol fuel plant to... that the spirits or fuel alcohol contained therein is a sample. The proprietor shall account for...
Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148
Veggie ISS Validation Test Results and Produce Consumption
NASA Technical Reports Server (NTRS)
Massa, Gioia; Hummerick, Mary; Spencer, LaShelle; Smith, Trent
2015-01-01
The Veggie vegetable production system flew to the International Space Station (ISS) in the spring of 2014. The first set of plants, Outredgeous red romaine lettuce, was grown, harvested, frozen, and returned to Earth in October. Ground control and flight plant tissue was sub-sectioned for microbial analysis, anthocyanin antioxidant phenolic analysis, and elemental analysis. Microbial analysis was also performed on samples swabbed on orbit from plants, Veggie bellows, and plant pillow surfaces, on water samples, and on samples of roots, media, and wick material from two returned plant pillows. Microbial levels of plants were comparable to ground controls, with some differences in community composition. The range in aerobic bacterial plate counts between individual plants was much greater in the ground controls than in flight plants. No pathogens were found. Anthocyanin concentrations were the same between ground and flight plants, while antioxidant and phenolic levels were slightly higher in flight plants. Elements varied, but key target elements for astronaut nutrition were similar between ground and flight plants. Aerobic plate counts of the flight plant pillow components were significantly higher than ground controls. Surface swab samples showed low microbial counts, with most below detection limits. Flight plant microbial levels were less than bacterial guidelines set for non-thermostabalized food and near or below those for fungi. These guidelines are not for fresh produce but are the closest approximate standards. Forward work includes the development of standards for space-grown produce. A produce consumption strategy for Veggie on ISS includes pre-flight assessments of all crops to down select candidates, wiping flight-grown plants with sanitizing food wipes, and regular Veggie hardware cleaning and microbial monitoring. Produce then could be consumed by astronauts, however some plant material would be reserved and returned for analysis. Implementation of this plan is a step toward developing pick-and-eat food production to supplement the packaged diet on ISS and for future exploration missions where plants could make up a larger portion of the diet. Supported by NASA Space Biology Program.
Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.
Corrigan, Damion K; Piletsky, Sergey; McCrossen, Sean
2009-01-01
This article compares the technical performances of several different commercially available swabbing materials for the purpose of cleaning verification. A steel surface was soiled with solutions of acetaminophen, nicotinic acid, diclofenac, and benzamidine and wiped with each swabbing material. The compounds were extracted with water or ethanol (depending on polarity of analyte) and their concentration in extract was quantified spectrophotometrically. The study also investigated swab debris on the wiped surface. The swab performances were compared and the best swab material was identified.
Nerandzic, Michelle M.; Rackaityte, Elze; Jury, Lucy A.; Eckart, Kevin; Donskey, Curtis J.
2013-01-01
Background Removing spores of Clostridium difficile and Bacillus anthracis from skin is challenging because they are resistant to commonly used antimicrobials and soap and water washing provides only modest efficacy. We hypothesized that hygiene interventions incorporating a sporicidal electrochemically generated hypochlorous acid solution (Vashe®) would reduce the burden of spores on skin. Methods Hands of volunteers were inoculated with non-toxigenic C. difficile spores or B. anthracis spore surrogates to assess the effectiveness of Vashe solution for reducing spores on skin. Reduction in spores was compared for Vashe hygiene interventions versus soap and water (control). To determine the effectiveness of Vashe solution for removal of C. difficile spores from the skin of patients with C. difficile infection (CDI), reductions in levels of spores on skin were compared for soap and water versus Vashe bed baths. Results Spore removal from hands was enhanced with Vashe soak (>2.5 log10 reduction) versus soap and water wash or soak (~2.0 log10 reduction; P <0.05) and Vashe wipes versus alcohol wipes (P <0.01). A combined approach of soap and water wash followed by soaking in Vashe removed >3.5 log10 spores from hands (P <0.01 compared to washing or soaking alone). Bed baths using soap and water (N =26 patients) did not reduce the percentage of positive skin cultures for CDI patients (64% before versus 57% after bathing; P =0.5), whereas bathing with Vashe solution (N =21 patients) significantly reduced skin contamination (54% before versus 8% after bathing; P =0.0001). Vashe was well-tolerated with no evidence of adverse effects on skin. Conclusions Vashe was safe and effective for reducing the burden of B. anthracis surrogates and C. difficile spores on hands. Bed baths with Vashe were effective for reducing C. difficile on skin. These findings suggest a novel strategy to reduce the burden of spores on skin. PMID:23844234
Stowell, Jennifer D; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L; Dollard, Sheila C; Bialek, Stephanie R; Cannon, Michael J; Schmid, D Scott
2014-01-01
Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 10(5) infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands.
Stowell, Jennifer D.; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L.; Dollard, Sheila C.; Bialek, Stephanie R.; Cannon, Michael J.
2014-01-01
Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 105 infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands. PMID:24185855
Colombo, Manuel; Jeronimo, Matthew; Astrakianakis, George; Apte, Chirag; Hon, Chun-Yip
2017-10-01
This paper describes a novel wipe sampling and high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method capable of simultaneously detecting 10 antineoplastic drugs (5-fluorouracil, oxaliplatin, methotrexate, vindesine, ifosfamide, cyclophosphamide, vincristine, vinblastine, docetaxel, and paclitaxel). The good overall recoveries and sensitivity values of this method along with the comparatively short run time (8 min) allows for its use in routine monitoring in health care facilities. The long-term behavior of the studied drugs on contaminated surfaces and the effect of surface roughness on drug recoveries were studied to gain insights about how these environmental variables influence the detection, cleaning, and occupational exposure of these drugs. Surfaces with higher roughness parameter (Ra) values (rougher) had the lowest recoveries while those with lower Ra (smoother) presented the highest recoveries. Long-term assessments evidence distinctive drug behaviors with oxaliplatin, vindesine, vincristine, and vinblastine being the less persistent drugs (~20% was recovered after 24 h) and docetaxel and paclitaxel the most persistent drugs with recoveries of 40% and 80% after 1 month. This information indicates the importance of collecting ancillary information about drug usage (throughput, timing, cleaning procedures, etc.) to interpret the results in the context of potential exposure. Finally, the method was successfully applied to evaluate trace surface contamination down to the single picogram per square centimeter in multiple work areas within three local health care centers on Vancouver Island, Canada. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Residual tobacco smoke pollution in used cars for sale: air, dust, and surfaces.
Matt, Georg E; Quintana, Penelope J E; Hovell, Melbourne F; Chatfield, Dale; Ma, Debbie S; Romero, Romina; Uribe, Anna
2008-09-01
Regular tobacco use in the enclosed environment of a car raises concerns about longer-term contamination of a car's microenvironment with residual secondhand smoke pollutants. This study (a) developed and compared methods to measure residual contamination of cars with secondhand smoke, (b) examined whether cars of smokers and nonsmokers were contaminated by secondhand smoke, and (c) how smoking behavior and restrictions affected contamination levels. Surface wipe, dust, and air samples were collected in used cars sold by nonsmokers (n = 20) and smokers (n = 87) and analyzed for nicotine. Sellers were interviewed about smoking behavior and restrictions, and car interiors were inspected for signs of tobacco use. Cars of smokers who smoked in their vehicles showed significantly elevated levels of nicotine (p < .001) in dust, on surfaces, and in the air compared with nonsmoker cars with smoking ban. When smokers imposed car smoking bans, air nicotine levels were significantly lower (p < .01), but dust and surface contamination levels remained at similar levels. Smoking more cigarettes in the car and overall higher smoking rate of the seller were significantly associated with higher secondhand smoke contamination of the car (p < .001). Use of a cutpoint for nicotine levels from surface wipe samples correctly identified 82% of smoker cars without smoking bans, 75% of smoker cars with bans, and 100% of nonsmoker cars. Surface nicotine levels provide a relatively inexpensive and accurate method to identify cars and other indoor environments contaminated with residual secondhand smoke. Disclosure requirements and smoke-free certifications could help protect nonsmoking buyers of used cars.
Kenters, Nikki; Huijskens, Elisabeth G W; de Wit, Sophie C J; van Rosmalen, Joost; Voss, Andreas
2017-08-01
Hospital rooms play an important role in the transmission of several health care-associated pathogens. During the last few years, a number of innovative cleaning-disinfecting products have been brought to market. In this study, commercially available products combining cleaning and disinfection were compared, using 2 different application methods. The aim was to determine which product was most effective in simultaneous cleaning and disinfection of surfaces. Seven cleaning-disinfecting wipes and sprays based on different active ingredients were tested for their efficacy in removal of microbial burden and proteins. Efficacy was tested with known Dutch outbreak strains: vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae OXA-48, or Acinetobacter baumannii. For all bacteria, ready-to-use cleaning-disinfecting products reduced the microbial count with a log 10 reduction >5 with a 5-minute exposure time, with the exception of a spray based on hydrogen peroxide. Omitting the aforementioned hydrogen peroxide spray, there were no significant differences between use of a wipe or spray in bacterial load reduction. Using adenosine triphosphate (ATP) measurements, a significant difference in log 10 relative light units (RLU) reduction between various bacteria (P ≤ .001) was observed. In general, a >5 log 10 reduction of colony forming units (CFU) for tested wipes and sprays was obtained for all tested bacteria strains, with exception of hydrogen peroxide spray and VRE. Although ATP may show a difference between pre- and postcleaning, RLU reduction does not correlate with actual CFU reductions. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
A sampling device with a capped body and detachable handle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jezek, Gerd-Rainer
1997-12-01
The present invention relates to a device for sampling radioactive waste and more particularly to a device for sampling radioactive waste which prevents contamination of a sampled material and the environment surrounding the sampled material. During vitrification of nuclear wastes, it is necessary to remove contamination from the surfaces of canisters filled with radioactive glass. After removal of contamination, a sampling device is used to test the surface of the canister. The one piece sampling device currently in use creates a potential for spreading contamination during vitrification operations. During operations, the one piece sampling device is transferred into and outmore » of the vitrification cell through a transfer drawer. Inside the cell, a remote control device handles the sampling device to wipe the surface of the canister. A one piece sampling device can be contaminated by the remote control device prior to use. Further, the sample device can also contaminate the transfer drawer producing false readings for radioactive material. The present invention overcomes this problem by enclosing the sampling pad in a cap. The removable handle is reused which reduces the amount of waste material.« less
Arhun, Neslihan; Cehreli, Sevi Burcak
2013-01-01
Reestablishing proximal contacts with composite resins may prove challenging since the applied adhesives may lead to resin coating that produces additional thickness. The aim of this study was to investigate the surface of metal matrix bands after application of adhesive systems and blowing or wiping off the adhesive before polymerization. Seventeen groups of matrix bands were prepared. The remnant particles were characterized by energy dispersive spectrum and scanning electron microscopy. Total etch and two-step self-etch adhesives did not leave any resin residues by wiping and blowing off. All-in-one adhesive revealed resin residues despite wiping off. Prime and Bond NT did not leave any remnant with compomer. Clinicians must be made aware of the consequences of possible adhesive remnants on matrix bands that may lead to a defective definitive restoration. The adhesive resin used for Class II restorations may leave resin coats on metal matrix bands after polymerization, resulting in additional thickness on the metal matrix bands and poor quality of the proximal surface of the definitive restoration when the adhesive system is incorporated in the restoration.
Tamaddonfard, Esmaeal; Hamzeh-Gooshchi, Nasrin
2010-01-01
The present study investigated the effects of subcutaneous (sc) and intracerebroventricular (icv) injections of physostigmine (a cholinesterase inhibitor), atropine (an antagonist of muscarinic cholinergic receptors) and hexamethonium (an antagonist of nicotinic cholinergic receptors) on the acute corneal nociception in rats. Local application of 5 M NaCl solution on the corneal surface of the eye produced a significant nociceptive behavior, characterized by eye wiping. The number of eye wipes was counted during the first 30 s. The sc (0.25, 0.5 and 1 mg/kg) and icv (1.25, 2.5, 5 and 10 μg) injections of physostigmine significantly (p < 0.05) decreased the number of eye wipes. Atropine and hexamethonium at (2 mg/kg, sc and 20 μg, icv) had no effects when used alone, however, atropine, but not hexamethonium prevented the antinociception induced by physostigmine (sc and icv). The results of this study indicate that the central muscarinic, but not nicotinic receptors might be involved in the antinociceptive effect of physostigmine in the acute corneal model of pain in rats.
Surface cleanliness measurement procedure
Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank
2002-01-01
A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.
Tools for measuring surface cleanliness
Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank
2002-01-01
A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.
NASA Technical Reports Server (NTRS)
Keen, Jill M.; DeWeese, Darrell C.; Key, Leigh W.
1997-01-01
At Kennedy Space Center (KSC), Thiokol Corporation provides the engineering to assemble and prepare the Space Shuttle Reusable Solid Rocket Motor (RSRM) for launch. This requires hand cleaning over 86 surfaces including metals, adhesives, rubber and electrical insulations, various painted surfaces and thermal protective materials. Due to the phase-out of certain ozone depleting chemical (ODC) solvents, all RSRM hand wipe operations being performed at KSC using l,l,1-trichloroethane (TCA) were eliminated. This presentation summarizes the approach used and the data gathered in the effort to eliminate TCA from KSC hand wipe operations.
2010-02-01
APPENDIXES A. COUPON STOCK MATERIAL AND PREPARATION 141 B. CONTROL CHARTS 143 C. ANALYTICAL INSTRUMENTATION PARAMETERS 171 D. COUPON CHAIN-OF...were cut from stock material. Vitron® is a registered trademark of Vitron Manufacturing, Phoenix, AZ Kapton® is a register trademark of E.I. DuPont... Eft Wipe Wipe Ext. Eff. 15M 15M 15M 15M 0 300 600 0 4/4 5/5 5/5 4/4 3,740,999 ± 2,377,014 135876 ±51295 50896 ± 38227 120004 ±8130
Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor
Britten, Jerald A.
1997-01-01
A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for 1) cleaning, developing or etching, 2) rinsing, and 3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material.
Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor
Britten, J.A.
1997-08-26
A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for (1) cleaning, developing or etching, (2) rinsing, and (3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material. 5 figs.
Lead exposure in Mexican radiator repair workers.
Dykeman, Ronald; Aguilar-Madrid, Guadalupe; Smith, Tom; Juárez-Pérez, Cuauhtemoc Arturo; Piacitelli, Gregory M; Hu, Howard; Hernandez-Avila, Mauricio
2002-03-01
Lead exposure was investigated among 73 Mexican radiator repair workers (RRWs), 12 members of their family (4 children and 8 wives), and 36 working controls. RRWs were employed at 4 radiator repair shops in Mexico City and 27 shops in Cuernavaca and surrounding areas. Exposure was assessed directly through the use of personal air sampling and hand wipe samples. In addition, industrial hygiene inspections were performed and detailed questionnaires were administered. Blood lead levels were measured by graphite furnace atomic absorption spectroscopy (AAS). The mean (SD) values for blood lead of the RRWs, 35.5 (13.5) microg/dl, was significantly greater than the same values for the working controls, 13.6 (8.7) microg/dl; P < 001. After excluding a single outlier (247 microg/m(3)), air lead levels ranged from 0 to 99 microg/m(3) with a mean (SD) value of 19 (23) microg/m(3) (median = 7.9 microg/m(3)). In a final multivariate regression model of elevated blood lead levels, the strongest predictors were smoking (vs. non-smoking), the number of radiators repaired per day on average, and the use (vs. non-use) of a uniform while at work, which were associated with blood lead elevations of 11.4 microg/dl, 1.95 microg/dl/radiator/day, and 16.4 microg/dl, respectively (all P <.05). Uniform use was probably a risk factor because they were not laundered regularly and consequently served as reservoir of contamination on which RRWs frequently wiped their hands. Lead exposure is a significant problem of radiator repair work, a small industry that is abundant in Mexico and other developing countries. Copyright 2002 Wiley-Liss, Inc.
27 CFR 25.53 - Submissions of samples of fermented products.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Submissions of samples of fermented products. 25.53 Section 25.53 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Miscellaneous Provisions Samples § 25.53...
[Determination of lead in edible salt with solid-phase extraction and GFAAS].
Zhao, Xin; Zhou, Shuang; Ma, Lan; Yang, Dajin
2013-01-01
Establishing a method for determination of lead in salt with solid-phase extraction and GFAAS. Salt sample was diluted to a certain volume directly with ammonium acetate, then the sample solution was filtered through the solid phase extraction column which has been pre-activated. Lead ions were retained, and the sodium chloride matrix was removed. After elution, the collected lead ions was determined by graphite furnace atomic absorption spectrometry in 257.4 nm. This method can be used effectively to wipe off the sodium chloride in matrix. The limit of detection was 0.7 microg/kg and the limit of quantification was 2 microg/kg. Solid phase extraction technique can be used effectively to reduce the interference in matrix and improves the accuracy and reproducibility of detection.
NASA Astrophysics Data System (ADS)
Farahi, Maria; Rabbani, Hossein; Talebi, Ardeshir; Sarrafzadeh, Omid; Ensafi, Shahab
2015-12-01
Visceral Leishmaniasis is a parasitic disease that affects liver, spleen and bone marrow. According to World Health Organization report, definitive diagnosis is possible just by direct observation of the Leishman body in the microscopic image taken from bone marrow samples. We utilize morphological and CV level set method to segment Leishman bodies in digital color microscopic images captured from bone marrow samples. Linear contrast stretching method is used for image enhancement and morphological method is applied to determine the parasite regions and wipe up unwanted objects. Modified global and local CV level set methods are proposed for segmentation and a shape based stopping factor is used to hasten the algorithm. Manual segmentation is considered as ground truth to evaluate the proposed method. This method is tested on 28 samples and achieved 10.90% mean of segmentation error for global model and 9.76% for local model.
Shepard, Michele; Brenner, Sara
2014-01-01
Numerous studies are ongoing in the fields of nanotoxicology and exposure science; however, gaps remain in identifying and evaluating potential exposures from skin contact with engineered nanoparticles in occupational settings. The aim of this study was to identify potential cutaneous exposure scenarios at a workplace using engineered nanoparticles (alumina, ceria, amorphous silica) and evaluate the presence of these materials on workplace surfaces. Process review, workplace observations, and preliminary surface sampling were conducted using microvacuum and wipe sample collection methods and transmission electron microscopy with elemental analysis. Exposure scenarios were identified with potential for incidental contact. Nanoparticles of silica or silica and/or alumina agglomerates (or aggregates) were identified in surface samples from work areas where engineered nanoparticles were used or handled. Additional data are needed to evaluate occupational exposures from skin contact with engineered nanoparticles; precautionary measures should be used to minimize potential cutaneous exposures in the workplace.
2003-09-03
KENNEDY SPACE CENTER, FLA. - A KSC employee wipes down some of the hoses of the ground support equipment in the Orbiter Processing Facility (OPF) where Space Shuttle Atlantis is being processed for flight. Preparations are under way for the next launch of Atlantis on mission STS-114, a utilization and logistics flight to the International Space Station.
The use of twin screw extruders for feeding coal against pressures of up to 1500 PSI
NASA Technical Reports Server (NTRS)
Wiedmann, W.; Mack, W. A.
1977-01-01
Recent tests with a twin-screw, co-rotating extruder which was successfully used to convey and feed coal against pressures of up to 1500 psi are described. Intermeshing and self-wiping, co-rotating twin-screws give greatly improved conveying and pressure built-up capabilities and avoid hangup and eventual decomposition of coal particles in the screw flights. The conveying action of intermeshing, self-wiping, co-rotating extruder systems approaches that of a positive displacement pump. With this feature, it is possible to maintain very accurate control over all aspects of product conveyance in the extruder, i.e., intake, conveyance and pressure buildup.
Benefits of automated surface decontamination of a radioiodine ward.
Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan
2012-02-01
A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.
Perceiving non-native speech: Word segmentation
NASA Astrophysics Data System (ADS)
Mondini, Michèle; Miller, Joanne L.
2004-05-01
One important source of information listeners use to segment speech into discrete words is allophonic variation at word junctures. Previous research has shown that non-native speakers impose their native-language phonetic norms on their second language; as a consequence, non-native speech may (in some cases) exhibit altered patterns of allophonic variation at word junctures. We investigated the perceptual consequences of this for word segmentation by presenting native-English listeners with English word pairs produced either by six native-English speakers or six highly fluent, native-French speakers of English. The target word pairs had contrastive word juncture involving voiceless stop consonants (e.g., why pink/wipe ink; gray ties/great eyes; we cash/weak ash). The task was to identify randomized instances of each individual target word pair (as well as control pairs) by selecting one of four possible choices (e.g., why pink, wipe ink, why ink, wipe pink). Overall, listeners were more accurate in identifying target word pairs produced by the native-English speakers than by the non-native English speakers. These findings suggest that one contribution to the processing cost associated with listening to non-native speech may be the presence of altered allophonic information important for word segmentation. [Work supported by NIH/NIDCD.
Clausen, Per Axel; Spaan, Suzanne; Brouwer, Derk H; Marquart, Hans; le Feber, Maaike; Engel, Roel; Geerts, Lieve; Jensen, Keld Alstrup; Kofoed-Sørensen, Vivi; Hansen, Brian; De Brouwere, Katleen
2016-01-01
The aim of this work was to identify the key mechanisms governing transport of organic chemical substances from consumer articles to cotton wipes. The results were used to establish a mechanistic model to improve assessment of dermal contact exposure. Four types of PVC flooring, 10 types of textiles and one type of inkjet printed paper were used to establish the mechanisms and model. Kinetic extraction studies in methanol demonstrated existence of matrix diffusion and indicated the presence of a substance surface layer on some articles. Consequently, the proposed substance transfer model considers mechanical transport from a surface film and matrix diffusion in an article with a known initial total substance concentration. The estimated chemical substance transfer values to cotton wipes were comparable to the literature data (relative transfer ∼ 2%), whereas relative transfer efficiencies from spiked substrates were high (∼ 50%). For consumer articles, high correlation (r(2)=0.92) was observed between predicted and measured transfer efficiencies, but concentrations were overpredicted by a factor of 10. Adjusting the relative transfer from about 50% used in the model to about 2.5% removed overprediction. Further studies are required to confirm the model for generic use.
Contributions of Paint and Soil to Pb in Household Dust Wipes: An XAS Study
NASA Astrophysics Data System (ADS)
Pingitore, N. E.; Clague, J. W.; Amaya, M. A.
2010-12-01
Speciation of Pb by X-ray absorption spectroscopy (XAS) indicated that Pb compounds associated with lead-based paint accounted for perhaps half of the Pb in 24 household dust wipes collected in El Paso, Texas. Soil-derived, sorbed Pb, likely Pb-humate, was also a major Pb species in many of the dust wipes. Household dust wipes are a standard technique for evaluating health risks of Pb to children, particularly toddlers, in public and private housing. The level of Pb in the wipes does not, however, indicate whether the source of the Pb is the house itself (peeling or powdering interior or exterior paint) or external, from contaminated soil or airborne particulate matter brought into the house by wind or foot traction. Understanding the origin of Pb in household dust is important in remediation: cover the old paint or remove the yard soil. XAS speciation can assist in understanding the source of Pb in household dust. The presence of significant Pb-humate requires a soil source, and suggests the need for soil remediation. Such species of Pb as hydrocerussite, lead sulfate, lead silicate, and lead chromate can be presumed to be components of lead-based paint. These may represent interior and/or exterior paint and thus do not uniquely identify the locus of the Pb source(s). Pb L-III edge XAFS data were collected on beam lines 7-3, 10-2, and 11-2 at SSRL at typical conditions of 3 GeV field and 80-200 mA current, using Si(220) water- or liquid-nitrogen-cooled monochromator crystals. Data were collected at ambient temperature in fluorescence mode using a 13- or 30-element Ge detector with a Se 3 or 6 filter and Soller slits to reduce scattered radiation. This publication was made possible by grant numbers 1RO1-ES11367 and 1 S11 ES013339-01A1 from the National Institute of Environmental Health Sciences (NIEHS), NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIEHS, NIH. Portions of this research were carried out at the Stanford Synchrotron Radiation Lightsource, a national user facility operated by Stanford University on behalf of the U.S. Department of Energy, Office of Basic Energy Sciences.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Samples. The following rules apply to the testing and analysis of samples of spirits and fuel alcohol for purposes of this subpart: (a) A proprietor may take samples of spirits and fuel alcohol for on-site testing and analysis at the proprietor's alcohol fuel plant; (b) A proprietor may not remove samples of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca
2011-11-28
This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Othermore » key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.« less
Kane, Jeremy C; Johnson, Renee M; Robinson, Courtland; Jernigan, David H; Harachi, Tracy W; Bass, Judith K
2016-11-01
Recent studies indicate that alcohol use is increasing among Asian American populations and that acculturation impacts alcohol use among immigrants in the USA. We investigated the longitudinal relationship between three domains of acculturation (traditionalism, biculturalism, assimilation) and alcohol use among 302 Vietnamese and Cambodian women in Washington State. Data were obtained from the Cross Cultural Families Project (CCF), a 5-year longitudinal investigation of a random sample of Vietnamese and Cambodian immigrant families living in Washington State. Alcohol use was measured with a three item scale assessing frequency and quantity of use, and binge drinking. Acculturation was measured with the Suinn-Lew Asian Self-Identity Acculturation Scale. Linear mixed effects regression models were estimated to assess the impact of acculturation on alcohol use among the overall sample and among a sub-sample of only women who consumed any alcohol. A majority of the sample, 73.2%, reported no alcohol use. In the overall sample, none of the three acculturation domains were significantly associated with drinking. Among a sub-sample of only those who reported any alcohol use, however, a greater degree of traditional cultural identification (β = -0.94, SE= 0.44, P= 0.03) and a greater degree of biculturalism (β = -1.33, SE= 0.53, P =0.01) were associated with lower levels of use. Our findings suggest that acculturation did not impact alcohol use prevalence but that it did affect the drinking pattern among alcohol consumers. Clinicians should be cognizant that certain aspects of cultural identification are important contributors to drinking behavior among alcohol consumers in these populations. © The Author 2016. Medical Council on Alcohol and Oxford University Press. All rights reserved.
Detection of indoor biological hazards using the man-portable laser induced breakdown spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munson, Chase A.; Gottfried, Jennifer L.; Snyder, Emily Gibb
2008-11-01
The performance of a man-portable laser induced breakdown spectrometer was evaluated for the detection of biological powders on indoor office surfaces and wipe materials. Identification of pure unknown powders was performed by comparing against a library of spectra containing biological agent surrogates and confusant materials, such as dusts, diesel soot, natural and artificial sweeteners, and drink powders, using linear correlation analysis. Simple models constructed using a second technique, partial least squares discriminant analysis, successfully identified Bacillus subtilis (BG) spores on wipe materials and office surfaces. Furthermore, these models were able to identify BG on materials not used in the trainingmore » of the model.« less
NASA Astrophysics Data System (ADS)
Pearle, Philip
1982-03-01
In the problem of the gambler's ruin, a classic problem in probability theory, a number of gamblers play against each other until all but one of them is “wiped out.” It is shown that this problem is identical to a previously presented formulation of the reduction of the state vector, so that the state vectors in a linear superposition may be regarded as “playing” against each other until all but one of them is “wiped out.” This is a useful part of the description of an objectively real universe represented by a state vector that is a superposition of macroscopically distinguishable states dynamically created by the Hamiltonian and destroyed by the reduction mechanism.
27 CFR 19.18 - Samples for the United States.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Provisions § 19.18 Samples for the United States. TTB officers are authorized to take samples of spirits... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Samples for the United States. 19.18 Section 19.18 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE...
27 CFR 24.37 - Samples for the United States.
Code of Federal Regulations, 2011 CFR
2011-04-01
... § 24.37 Samples for the United States. Appropriate TTB officers are authorized to take samples of wine... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Samples for the United States. 24.37 Section 24.37 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE...
Kekwaletswe, C T; Nkosi, S; Kitleli, N B; Myers, B; Shuper, P; Parry, C D H; Morojele, N K
2018-05-20
To achieve the maximal therapeutic benefits of antiretroviral therapy (ART), high adherence is required. In South Africa, ART recipients are usually counselled by their health care providers to stop drinking alcohol, as heavy alcohol use compromises ART adherence. Patients who continue drinking alcohol tend to hide their alcohol-related adherence challenges from their health care providers. Objective measures of ART adherence/exposure may help to better identify drinkers who could benefit from ART adherence enhancement interventions. To evaluate the acceptability of collecting hair samples to objectively assess ART exposure among alcohol drinkers, we conducted four mixed-gender focus group discussions (FGDs) with alcohol drinking ART recipients at two ART sites in Tshwane, South Africa. Data were analysed using content analysis. ART recipients found hair sample testing for ART exposure to be novel and therefore expected that some ART recipients would initially be hesitant to provide a sample. Participants thought that the acceptability of hair sample collection could be enhanced by providing a full explanation of how the hair sample would be obtained and what the testing would entail. Participants also viewed hair sample testing as a viable and desirable alternative to blood sample testing for ART exposure. Some worries about the possible use of hair samples for witchcraft and the symbolic nature of hair were brought up, but these were not seen as insurmountable concerns. In conclusion, hair sample testing is a potentially acceptable method of assessing ART exposure amongst ART recipients who drink alcohol.
HYDROLYSIS OF MTBE TO TBA IN GROUND WATER SAMPLES WITH HYDROCHLORIC ACID
Conventional sampling and analytical protocols have poor sensitivity for fuel oxygenates that are alcohols, such as tert-butyl alcohol (TBA). Because alcohols are miscible or highly soluble in water, alcohols are not efficiently transferred to the gas chromatograph for analysis....
Elevated Behavioral Economic Demand for Alcohol in a Community Sample of Heavy Drinking Smokers.
Amlung, Michael; MacKillop, James; Monti, Peter M; Miranda, Robert
2017-05-01
Cigarette smokers are more likely to consume alcohol at higher levels and experience poorer response to treatment for alcohol problems than are nonsmokers. One previous study in university students suggests that a potential reason for the high overlap between alcohol and tobacco use is that concurrent smoking is associated with overvaluation of alcohol, as reflected in elevated behavioral economic demand. The present study sought to extend these initial findings in a community sample with heavier levels of alcohol and tobacco use. Participants were 111 non-treatment-seeking heavy drinkers(defined as 18+/14+ drinks per week for men/women) from a larger study on alcohol pharmacotherapy mechanisms. Forty-nine participants (44%) reported regular smoking (≥5 cigarettes/day). Participants completed a hypothetical alcohol purchase task assessing alcohol consumption at escalating levels of price. Covariates included demographics, drinking quantity, alcohol use disorder severity, depression, and delay discounting. In covariate-adjusted models, smokers reported significantly higher maximum alcohol expenditures (O max ) and breakpoint price (first price suppressing consumption to zero) compared with nonsmokers. Elevated alcohol demand correlated with drinking quantity and severity in the entire sample, but not with smoking frequency or nicotine dependence among smokers only. This study offers further evidence of increased reinforcing value of alcohol among smokers in a sample of heavy drinkers from the community. Clinical implications and potential mechanisms underlying this relationship are discussed.
Radio Science Measurements with Suppressed Carrier
NASA Technical Reports Server (NTRS)
Asmar, Sami; Divsalar, Dariush; Oudrhiri, Kamal
2013-01-01
Radio Science started when it became apparent with early Solar missions that occultations by planetary atmospheres would affect the quality of radio communications. Since then the atmospheric properties and other aspects of planetary science, solar science, and fundamental physics were studied by scientists. Radio Science data was always extracted from a received pure residual carrier (without data modulation). For some missions, it is very desirable to obtain Radio Science data from a suppressed carrier modulation. In this paper we propose a method to extract Radio Science data when a coded suppressed carrier modulation is used in deep space communications. Type of modulation can be BPSK, QPSK, OQPSK, MPSK or even GMSK. However we concentrate mostly on BPSK modulation. The proposed method for suppressed carrier simply tries to wipe out data that acts as an interference for Radio Science measurements. In order to measure the estimation errors in amplitude and phase of the Radio Science data we use Cramer-Rao bound (CRB). The CRB for the suppressed carrier modulation with non-ideal data wiping is then compared with residual carrier modulation under the same noise condition. The method of derivation of CRB for non-ideal data wiping is an innovative method that presented here. Some numerical results are provided for coded system.
Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P
2015-08-13
Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of 14 C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of 14 C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.
Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P
2016-01-01
Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of (14)C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of (14)C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.
Panadero, Sonia; Vázquez, José Juan; Martín, Rosa María
2016-06-14
The work analyzes different aspects related to alcohol consumption among homeless people and people at risk of social exclusion. The data was gathered from a representative sample of homeless people in Madrid (n = 188) and a sample of people at risk of social exclusion (n = 164) matched in sex, age, and origin (Spaniards vs. foreigners). The results showed that homeless people present a greater consumption of alcohol and have experienced more problems derived from its consumption than people at risk of social exclusion. Most of the homeless people who had alcohol-related problems had had them prior to their homelessness, and they stated they had poorer health and had experienced a greater number of homelessness episodes. Despite the relevance of problems related to alcohol among our sample, only a small percentage of the sample had participated in treatment programs for alcohol consumption.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Samples. 6.91 Section 6.91 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Exceptions § 6.91 Samples. The act by an industry member of furnishing or giving a sample of distilled spirits, wine, o...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Mark Patrick, E-mail: mark.taylor@mq.edu.au; Mould, Simon Anthony; Kristensen, Louise Jane
Although blood lead values in children are predominantly falling globally, there are locations where lead exposure remains a persistent problem. One such location is Broken Hill, Australia, where the percentage of blood lead values >10 μg/dL in children aged 1–4 years has risen from 12.6% (2010), to 13% (2011) to 21% (2012). The purpose of this study was to determine the extent of metal contamination in places accessible to children. This study examines contemporary exposure risks from arsenic, cadmium, lead, silver and zinc in surface soil and dust, and in pre- and post-play hand wipes at six playgrounds across Brokenmore » Hill over a 5-day period in September 2013. Soil lead (mean 2,450 mg/kg) and zinc (mean 3,710 mg/kg) were the most elevated metals in playgrounds. Surface dust lead concentrations were consistently elevated (mean 27,500 μg/m{sup 2}) with the highest lead in surface dust (59,900 μg/m{sup 2}) and post-play hand wipes (60,900 μg/m{sup 2}) recorded close to existing mining operations. Surface and post-play hand wipe dust values exceeded national guidelines for lead and international benchmarks for arsenic, cadmium and lead. Lead isotopic compositions ({sup 206}Pb/{sup 207}Pb, {sup 208}Pb/{sup 207}Pb) of surface dust wipes from the playgrounds revealed the source of lead contamination to be indistinct from the local Broken Hill ore body. The data suggest frequent, cumulative and ongoing mine-derived dust metal contamination poses a serious risk of harm to children. - Highlights: 1.Playground soils and surface dust in a mining town have high metal concentrations. 2.Elevated levels of As, Cd, Pb and Zn dust are found on playground users′ hands. 3.Pb isotope analysis shows that the source of playground dust is ore body Pb. 4.Surface mine operations must be contained to reduce childhood lead exposure risks. 5.Mine environmental licences need to set trigger values for As, Cd, Pb and Zn dust.« less
Bush, Derek; Goniewicz, Maciej L
2015-06-01
Nicotine deposited on the surfaces has been shown to react with airborne chemicals leading to formation of carcinogens and contributing to thirdhand exposure. While prior studies revealed nicotine residues in tobacco smokers' homes, none have examined the nicotine residue in electronic cigarette (e-cigarette) users' homes. We measured nicotine on the surfaces in households of 8 e-cigarette users, 6 cigarette smokers, and 8 non-users of nicotine-containing products in Western New York, USA. Three surface wipe samples were taken from the floor, wall and window. Nicotine was extracted from the wipes and analyzed using gas chromatography. Half of the e-cigarette users' homes had detectable levels of nicotine on surfaces whereas nicotine was found in all of the tobacco cigarette smokers' homes. Trace amounts of nicotine were also detected in half of the homes of non-users of nicotine-containing products. Nicotine levels in e-cigarette users homes was significantly lower than that found in cigarette smokers homes (average concentration 7.7±17.2 vs. 1303±2676 μg/m2; p<0.05). There was no significant difference in the amount of nicotine in homes of e-cigarette users and non-users (p>0.05). Nicotine is a common contaminant found on indoor surfaces. Using e-cigarettes indoors leads to significantly less thirdhand exposure to nicotine compared to smoking tobacco cigarettes. Copyright © 2015 Elsevier B.V. All rights reserved.
Solvent Replacement for Hydrochlorofluorocarbon-225 for Cleaning Oxygen System Components
NASA Technical Reports Server (NTRS)
Mitchell, M. A.; Lowrey, N. M.
2017-01-01
This Technical Memorandum is the result of a 2-year project funded by the Defense Logistics Agency-Aviation, Hazardous Minimization and Green Products Branch, to identify and test two candidate solvents to replace hydrochlorofluorocarbon-225 (HCFC-225) for cleaning oxygen systems. The solvents were also compared to a second solvent composed predominantly of perfluorobutyl iodide (PFBI), which had received limited approval by the United States Air Force (USAF) for hand wipe cleaning of components for aviators’ breathing oxygen systems. The tests performed for this study were based on those reported in AFRL-ML-WP-TR-2003-4040, “The Wipe Solvent Program,” the test program used to qualify Ikon® Solvent P for USAF applications.The study was completed in August 2014, prior to the completion of a more extensive study funded by the NASA Rocket Propulsion Test (RPT) program. The results of the RPT project are reported in NASA/TP-2015-18207, “Replacement of Hydrochlorofluorocarbon–225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems.” The test methods used in this study for nonvolatile residue (NVR) background, materials compatibility, and cleaning effectiveness were different than those used for the RPT project; a smaller set of materials and contaminants were tested. The tests for this study were complementary to and provided supplementary information for the down-selection process during the course of the test program reported in NASA/TP-2015-218207.
Drerup, Michelle L; Johnson, Thomas J; Bindl, Stephen
2011-12-01
Johnson et al. (2008b) reported that, in a college student sample, the effect of religiousness on alcohol use was mediated by negative beliefs about alcohol, social influences, and spiritual well-being, and that these variables in turn impacted alcohol use and problems both directly and indirectly via motives for drinking. This study attempted to replicate those findings in a sample of community dwelling adults (N=211). The effect of Religious/Spiritual Involvement was mediated by Negative Beliefs about Alcohol, Social Modeling, and Spiritual-Well-Being. However, Social Modeling had stronger relationships with motives for drinking and alcohol consumption than the other two mediators. The effect of Religious Struggle on Alcohol Problems was mediated by Spiritual Well-Being and coping motives for drinking. Results provide further support for the motivational model of alcohol use and suggest plausible mechanisms by which religiousness could causally impact alcohol use and problems. Religious struggle may be a clinically significant correlate of alcohol problems. Copyright © 2011 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Samples. 26.209 Section 26.209 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Samples. 26.209 Section 26.209 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Samples. 26.43 Section 26.43 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Samples. 26.43 Section 26.43 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Gulson, Brian; Taylor, Alan; Stifelman, Marc
2018-02-01
The US Environmental Protection Agency (EPA) Integrated Exposure Uptake Biokinetic (IEUBK) model has been widely used to predict blood lead (PbB) levels in children especially around industrial sites. Exposure variables have strongly focussed on the major contribution of lead (Pb) in soil and interior dust to total intake and, in many studies, site-specific data for air, water, diet and measured PbB were not available. We have applied the IEUBK model to a comprehensive data set, including measured PbB, for 108 children monitored over a 5-year period in Sydney, New South Wales, Australia. To use this data set, we have substituted available data (with or without modification) for standard inputs as needed. For example, as an alternative measure for soil Pb concentration (μg/g), we have substituted exterior dust sweepings Pb concentration (μg/g). As alternative measures for interior dust Pb concentration (μg/g) we have used 1) 30-day cumulative petri dish deposition data (PDD) (as µg Pb/m 2 /30days), or 2) hand wipe data (as μg Pb/hand). For comparison, simulations were also undertaken with estimates of dust Pb concentration derived from a prior regression of dust Pb concentration (μg/g) on dust Pb loading (μg/ft 2 ) as concentration is the unit specified for the Model. Simulations for each subject using observed data aggregated over the 5-year interval of the study, the most usual application of the IEUBK model, showed using Wilcoxon tests that there was a significant difference between the observed values and the values predicted by the Model containing soil with hand wipes (p < 0.001), and soil and PDD (p = 0.026) but not those for the other two sets of predictors, based on sweepings and PDD or sweepings and wipes. Overall, simulations of the Model using alternative exposure measures of petri dish dust (and possibly hand wipes) instead of vacuum cleaner dust and dust sweepings instead of soil provide predicted PbB which are generally consistent with each other and observed values. The predicted geometric mean PbBs were 2.17 ( ± 1.24) μg/dL for soil with PDD, 1.95 ( ± 1.17) μg/dL for soil with hand wipes, 2.36 ( ± 1.75) μg/dL for sweepings with PDD, and 2.15 ( ± 1.69) for sweepings with hand wipes. These results are in good agreement with the observed geometric mean PbB of 2.46 ( ± 0.99) μg/dL. In contrast to all other IEUBK model studies to our knowledge, we have stratified the data over the age ranges from 1 to 5 years. The median of the predicted values was lower than that for the observed values for every combination of age and set of measures; in some cases, the difference was statistically significant. The differences between observed and predicted PbB tended to be greatest for the soil plus wipes measure and for the oldest age group. Use of 'default dust' values calculated from the site-specific soil values, a common application of the IEUBK model, results in predicted PbB about 22% (range 0 to 52%) higher than those from soil with PDD data sets. Geometric mean contributions estimated from the Model to total Pb intake for a child aged 1-2 years was 0.09% for air, 42% for diet, 5.3% for water and 42% for soil and dust. Our results indicate that it is feasible to use alternative measures of soil and dust exposure to provide reliable predictions of PbB in urban environments. Copyright © 2017 Elsevier Inc. All rights reserved.
Andreuccetti, Gabriel; Leyton, Vilma; Lemos, Nikolas P; Miziara, Ivan Dieb; Ye, Yu; Takitane, Juliana; Munoz, Daniel Romero; Reingold, Arthur L; Cherpitel, Cheryl J; de Carvalho, Heraclito Barbosa
2017-04-01
Most studies reporting alcohol use among fatally injured victims are subject to bias, particularly those related to sample selection and to absence of injury context data. We developed a research method to estimate the prevalence of alcohol consumption and test correlates of alcohol use prior to fatal injuries. Cross-sectional study based on a probability sample of fatally injured adult victims (n = 365) autopsied in São Paulo, Brazil. Victims were sampled within systematically selected 8-hour sampling blocks, generating a representative sample of fatal injuries occurring during all hours of the day for each day of the week between June 2014 and December 2015. The presence of alcohol and blood alcohol concentration (BAC) were the primary outcomes evaluated according to victims' socio-demographic, injury context data (type, day, time and injury place) and criminal history characteristics. Alcohol was detected in 30.1% [95% confidence interval (CI) = 25.6-35.1)] of the victims, with a mean blood alcohol level (BAC) level of 0.11% w/v (95% CI = 0.09-0.13) among alcohol-positive cases. Black and mixed race victims presented a higher mean BAC than white victims (P = 0.03). Fewer than one in every six suicides tested positive for alcohol, while almost half of traffic-related casualties were alcohol-positive. Having suffered traffic-related injuries, particularly those involving vehicle crashes, and injuries occurring during weekends and at night were associated significantly with alcohol use before injury (P < 0.05). Nearly one-third of fatal injuries in São Paulo between June 2014 and December 2015 were alcohol-related, with traffic accidents showing a greater association with alcohol use than other injuries. The sampling methodology tested here, including the possibility of adding injury context data to improve population-based estimates of alcohol use before fatal injury, appears to be a reliable and lower-cost strategy for avoiding biases common in death investigations. © 2016 Society for the Study of Addiction.
27 CFR 25.53 - Submissions of samples of fermented products.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Submissions of samples of fermented products. 25.53 Section 25.53 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Miscellaneous Provisions Samples § 25.53...
27 CFR 25.53 - Submissions of samples of fermented products.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Submissions of samples of fermented products. 25.53 Section 25.53 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Miscellaneous Provisions Samples § 25.53...
27 CFR 25.53 - Submissions of samples of fermented products.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Submissions of samples of fermented products. 25.53 Section 25.53 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Miscellaneous Provisions Samples § 25.53...
Treutlein, Jens; Streit, Fabian; Juraeva, Dilafruz; Degenhardt, Franziska; Rietschel, Liz; Forstner, Andreas J.; Ridinger, Monika; Dukal, Helene; Foo, Jerome C.; Soyka, Michael; Maier, Wolfgang; Gaebel, Wolfgang; Dahmen, Norbert; Scherbaum, Norbert; Müller-Myhsok, Bertram; Lucae, Susanne; Ising, Marcus; Stickel, Felix; Berg, Thomas; Roggenbuck, Ulla; Jöckel, Karl-Heinz; Scholz, Henrike; Zimmermann, Ulrich S.; Buch, Stephan; Sommer, Wolfgang H.; Spanagel, Rainer; Brors, Benedikt; Cichon, Sven; Mann, Karl; Kiefer, Falk; Hampe, Jochen; Rosendahl, Jonas; Nöthen, Markus M.; Rietschel, Marcella
2017-01-01
The present study investigated the genetic contribution to alcohol dependence (AD) using genome-wide association data from three German samples. These comprised patients with: (i) AD; (ii) chronic alcoholic pancreatitis (ACP); and (iii) alcohol-related liver cirrhosis (ALC). Single marker, gene-based, and pathway analyses were conducted. A significant association was detected for the ADH1B locus in a gene-based approach (puncorrected = 1.2 × 10−6; pcorrected = 0.020). This was driven by the AD subsample. No association with ADH1B was found in the combined ACP + ALC sample. On first inspection, this seems surprising, since ADH1B is a robustly replicated risk gene for AD and may therefore be expected to be associated also with subgroups of AD patients. The negative finding in the ACP + ALC sample, however, may reflect genetic stratification as well as random fluctuation of allele frequencies in the cases and controls, demonstrating the importance of large samples in which the phenotype is well assessed. PMID:28714907
Treutlein, Jens; Frank, Josef; Streit, Fabian; Reinbold, Céline S; Juraeva, Dilafruz; Degenhardt, Franziska; Rietschel, Liz; Witt, Stephanie H; Forstner, Andreas J; Ridinger, Monika; Strohmaier, Jana; Wodarz, Norbert; Dukal, Helene; Foo, Jerome C; Hoffmann, Per; Herms, Stefan; Heilmann-Heimbach, Stefanie; Soyka, Michael; Maier, Wolfgang; Gaebel, Wolfgang; Dahmen, Norbert; Scherbaum, Norbert; Müller-Myhsok, Bertram; Lucae, Susanne; Ising, Marcus; Stickel, Felix; Berg, Thomas; Roggenbuck, Ulla; Jöckel, Karl-Heinz; Scholz, Henrike; Zimmermann, Ulrich S; Buch, Stephan; Sommer, Wolfgang H; Spanagel, Rainer; Brors, Benedikt; Cichon, Sven; Mann, Karl; Kiefer, Falk; Hampe, Jochen; Rosendahl, Jonas; Nöthen, Markus M; Rietschel, Marcella
2017-07-17
The present study investigated the genetic contribution to alcohol dependence (AD) using genome-wide association data from three German samples. These comprised patients with: (i) AD; (ii) chronic alcoholic pancreatitis (ACP); and (iii) alcohol-related liver cirrhosis (ALC). Single marker, gene-based, and pathway analyses were conducted. A significant association was detected for the ADH1B locus in a gene-based approach ( p uncorrected = 1.2 × 10 -6 ; p corrected = 0.020). This was driven by the AD subsample. No association with ADH1B was found in the combined ACP + ALC sample. On first inspection, this seems surprising, since ADH1B is a robustly replicated risk gene for AD and may therefore be expected to be associated also with subgroups of AD patients. The negative finding in the ACP + ALC sample, however, may reflect genetic stratification as well as random fluctuation of allele frequencies in the cases and controls, demonstrating the importance of large samples in which the phenotype is well assessed.
Woo, Kang-Lyung
2005-01-01
Low molecular weight alcohols including fusel oil were determined using diethyl ether extraction and capillary gas chromatography. Twelve kinds of alcohols were successfully resolved on the HP-FFAP (polyethylene glycol) capillary column. The diethyl ether extraction method was very useful for the analysis of alcohols in alcoholic beverages and biological samples with excellent cleanliness of the resulting chromatograms and high sensitivity compared to the direct injection method. Calibration graphs for all standard alcohols showed good linearity in the concentration range used, 0.001-2% (w/v) for all alcohols. Salting out effects were significant (p < 0.01) for the low molecular weight alcohols methanol, isopropanol, propanol, 2-butanol, n-butanol and ethanol, but not for the relatively high molecular weight alcohols amyl alcohol, isoamyl alcohol, and heptanol. The coefficients of variation of the relative molar responses were less than 5% for all of the alcohols. The limits of detection and quantitation were 1-5 and 10-60 microg/L for the diethyl ether extraction method, and 10-50 and 100-350 microg/L for the direct injection method, respectively. The retention times and relative retention times of standard alcohols were significantly shifted in the direct injection method when the injection volumes were changed, even with the same analysis conditions, but they were not influenced in the diethyl ether extraction method. The recoveries by the diethyl ether extraction method were greater than 95% for all samples and greater than 97% for biological samples.
A comprehensive review of arsenic levels in the semiconductor manufacturing industry.
Park, Donguk; Yang, Haengsun; Jeong, Jeeyeon; Ha, Kwonchul; Choi, Sangjun; Kim, Chinyon; Yoon, Chungsik; Park, Dooyong; Paek, Domyung
2010-11-01
This paper presents a summary of arsenic level statistics from air and wipe samples taken from studies conducted in fabrication operations. The main objectives of this study were not only to describe arsenic measurement data but also, through a literature review, to categorize fabrication workers in accordance with observed arsenic levels. All airborne arsenic measurements reported were included in the summary statistics for analysis of the measurement data. The arithmetic mean was estimated assuming a lognormal distribution from the geometric mean and the geometric standard deviation or the range. In addition, weighted arithmetic means (WAMs) were calculated based on the number of measurements reported for each mean. Analysis of variance (ANOVA) was employed to compare arsenic levels classified according to several categories such as the year, sampling type, location sampled, operation type, and cleaning technique. Nine papers were found reporting airborne arsenic measurement data from maintenance workers or maintenance areas in semiconductor chip-making plants. A total of 40 statistical summaries from seven articles were identified that represented a total of 423 airborne arsenic measurements. Arsenic exposure levels taken during normal operating activities in implantation operations (WAM = 1.6 μg m⁻³, no. of samples = 77, no. of statistical summaries = 2) were found to be lower than exposure levels of engineers who were involved in maintenance works (7.7 μg m⁻³, no. of samples = 181, no. of statistical summaries = 19). The highest level (WAM = 218.6 μg m⁻³) was associated with various maintenance works performed inside an ion implantation chamber. ANOVA revealed no significant differences in the WAM arsenic levels among the categorizations based on operation and sampling characteristics. Arsenic levels (56.4 μg m⁻³) recorded during maintenance works performed in dry conditions were found to be much higher than those from maintenance works in wet conditions (0.6 μg m⁻³). Arsenic levels from wipe samples in process areas after maintenance activities ranged from non-detectable to 146 μg cm⁻², indicating the potential for dispersion into the air and hence inhalation. We conclude that workers who are regularly or occasionally involved in maintenance work have higher potential for occupational exposure than other employees who are in charge of routine production work. In addition, fabrication workers can be classified into two groups based on the reviewed arsenic exposure levels: operators with potential for low levels of exposure and maintenance engineers with high levels of exposure. These classifications could be used as a basis for a qualitative ordinal ranking of exposure in an epidemiological study.
Sloane, Kate; Wilson, Nick; Imlach Gunasekara, Fiona
2013-01-01
We aimed to: (i) document the extent and nature of alcohol portrayal in televised music videos in New Zealand in 2010; and (ii) assess trends over time by comparing with a similar 2005 sample. We undertook a content analysis for references to alcohol in 861 music videos shown on a youth-orientated television channel in New Zealand. This was compared with a sample in 2005 (564 music videos on the same channel plus sampling from two other channels). The proportion of alcohol content in the music videos was slightly higher in 2010 than for the same channel in the 2005 sample (19.5% vs. 15.7%) but this difference was not statistically significant. Only in the genre 'Rhythm and Blues' was the increase over time significant (P = 0.015). In both studies, the portrayal of alcohol was significantly more common in music videos where the main artist was international (not from New Zealand). Furthermore, in the music videos with alcohol content, at least a third of the time, alcohol was shown being consumed and the main artist was involved with alcohol. In only 2% (in 2005) and 4% (in 2010) of these videos was the tone explicitly negative towards alcohol. In both these studies, the portrayal of alcohol was relatively common in music videos. Nevertheless, there are various ways that policy makers can denormalise alcohol in youth-orientated media such as music videos or to compensate via other alcohol control measures such as higher alcohol taxes. © 2012 Australasian Professional Society on Alcohol and other Drugs.
Paternal Alcoholism, Family Functioning, and Infant Mental Health
ERIC Educational Resources Information Center
Fitzgerald, Hiram E.; Eiden, Rina Das
2007-01-01
The authors share results from two longitudinal studies exploring the impact of father's alcohol use on child development. The Michigan Longitudinal Study (MLS) has followed a sample of alcoholic families with 3-5 year old children for 20 years. The Buffalo Longitudinal Study (BLS) has followed a sample of alcoholic and nonalcoholic families…
Partner Violence Before and After Couples-Based Alcoholism Treatment for Female Alcoholic Patients
Schumm, Jeremiah A.; O'Farrell, Timothy J.; Murphy, Christopher M.; Fals-Stewart, William
2010-01-01
This study examined partner violence before and in the first and second year after behavioral couples therapy (BCT) for 103 married or cohabiting women seeking alcohol dependence treatment and their male partners, and used a demographically matched non-alcoholic comparison sample. The treatment sample received M = 16.7 BCT sessions over 5-6 months. Follow-up rates for the treatment sample at years 1 and 2 were 88% and 83%, respectively. In the year before BCT, 68% of female alcoholic patients had been violent toward their male partner, nearly five times the comparison sample rate of 15%. In the year after BCT, violence prevalence decreased significantly to 31% of the treatment sample. Women were classified as remitted after treatment if they demonstrated abstinence or minimal substance use and no serious consequences related to substance use. In year 1 following BCT, 45% were classified as remitted, and 49% were classified as remitted in year 2. Among remitted patients in the year after BCT, violence prevalence of 22% did not differ from the comparison sample and was significantly lower than the rate among relapsed patients (38%). Results for male-perpetrated violence and for the second year after BCT were similar to the first year. Results supported predictions that partner violence would decrease after BCT, and that clinically significant violence reductions to the level of a non-alcoholic comparison sample would occur for patients whose alcoholism was remitted after BCT. These findings replicate previous research among men with alcoholism. PMID:19968389
[Study of a sample of alcoholic patients two years post-treatment].
Avila Escribano, J J; Pérez Madruga, A; Rodríguez Treceño, M
1994-01-01
This survey analyzes the evolution of one sample of alcoholic patients two years after finishing treatment. Its target is to determine the percentage of patients that remain abstinent, their rate of retention, and what factors can have an influence on abstinence. In 1990, 72 alcoholic patients were treated in the Alcoholism Unit, who make up our study sample. The average age was 37.9 +/- 11.47 years old; 77.8% were diagnosed as being Alcohol-dependents and 22.2% as Alcohol-abusers; 19.4% dropped out the treatment early. In 1992 our sample of study was 53 patients (2 died and 17 refused to participate), of whom 77.7% were abstinent and 28.3% continued ingesting alcohol; the average abstinence was 22.92 +/- 8.73 months. An important finding of this study was that the diagnosis, sex, and treatment with aversives had not an influence on abstinence; however the percentage of abstinent patients in those who had attended Therapeutic Discussion Groups was significantly higher than in those who had not.
Pleil, Joachim D; Lorber, Matthew N
2007-11-01
The United States Environmental Protection Agency collected ambient air samples in lower Manhattan for about 9 months following the September 11, 2001 World Trade Center (WTC) attacks. Measurements were made of a host of airborne contaminants including volatile organic compounds, polycyclic aromatic hydrocarbons, asbestos, lead, and other contaminants of concern. The present study focuses on the broad class of polychlorinated dibenzo-p-dioxins (CDDs) and dibenzofurans (CDFs) with specific emphasis on the 17 CDD/CDF congeners that exhibit mammalian toxicity. This work is a statistical study comparing the internal patterns of CDD/CDFs using data from an unambiguous fire event (WTC) and other data sets to help identify their sources. A subset of 29 samples all taken between September 16 and October 31, 2001 were treated as a basis set known to be heavily impacted by the WTC building fire source. A second basis set was created using data from Los Angeles and Oakland, CA as published by the California Air Resources Board (CARB) and treated as the archetypical background pattern for CDD/CDFs. The CARB data had a congener profile appearing similar to background air samples from different locations in America and around the world and in different matrices, such as background soils. Such disparate data would normally be interpreted with a qualitative pattern recognition based on congener bar graphs or other forms of factor or cluster analysis that group similar samples together graphically. The procedure developed here employs aspects of those statistical methods to develop a single continuous output variable per sample. Specifically, a form of variance structure-based cluster analysis is used to group congeners within samples to reduce collinearity in the basis sets, new variables are created based on these groups, and multivariate regression is applied to the reduced variable set to determine a predictive equation. This equation predicts a value for an output variable, OPT: the predicted value of OPT is near zero (0.00) for a background congener profile and near one (1.00) forthe profile characterized by the WTC air profile. Although this empirical method is calibrated with relatively small sets of airborne samples, it is shown to be generalizable to other WTC, fire source, and background air samples as well as other sample matrices including soils, window films and other dust wipes, and bulk dusts. However, given the limited data set examined, the method does not allow further discrimination between the WTC data and the other fire sources. This type of analysis is demonstrated to be useful for complex trace-level data sets with limited data and some below-detection entries.
Andreuccetti, Gabriel; Leyton, Vilma; Lemos, Nikolas P.; Miziara, Ivan Dieb; Ye, Yu; Takitane, Juliana; Munoz, Daniel Romero; Reingold, Arthur L.; Cherpitel, Cheryl J.; de Carvalho, Heraclito Barbosa
2016-01-01
Background and aims Most studies reporting alcohol use among fatally injured victims are subject to bias, particularly that related to sample selection and to absence of injury context data. We developed a research method to estimate the prevalence of alcohol consumption and test correlates of alcohol use prior to fatal injuries, using the city of Sao Paulo, Brazil as a model. Design, Setting and Participants Cross-sectional study based on a probability sample of fatally injured adult victims (N=365) autopsied in Sao Paulo, Brazil. Victims were sampled within systematically selected 8-hour sampling blocks, generating a representative sample of fatal injuries occurring during all hours of the day for each day of the week between June 2014 and December 2015. Measurements The presence of alcohol and blood alcohol concentration (BAC) were the primary outcomes evaluated according to victims’ socio-demographic, injury context data (type, day, time and injury place), and criminal history characteristics. Findings Alcohol was detected in 30.1% (CI 95%; 25.6–35.1) of the victims, with a mean BAC level of 0.11% w/v (CI 95%; 0.09–0.13) among alcohol-positive cases. Those black and mixed race presented a higher mean BAC than white victims (p=0.03). Less than one in every six suicides tested positive for alcohol, while almost half of traffic-related casualties were alcohol-positive. Having suffered traffic-related injuries, particularly those involving vehicle crashes, and injuries occurring during weekends and at night were significantly associated with alcohol use before injury (p<0.05). Conclusions Nearly one third of fatal injuries in Sao Paulo were alcohol-related, with traffic accidents showing a greater association with alcohol use than other injuries. The sampling methodology tested here, including the possibility of adding injury context data to improve population-based estimates of alcohol use before fatal injury, was found to be a reliable and lower cost strategy for avoiding biases common in death investigations. PMID:28044383
Shepard, Michele; Brenner, Sara
2014-01-01
Background: Numerous studies are ongoing in the fields of nanotoxicology and exposure science; however, gaps remain in identifying and evaluating potential exposures from skin contact with engineered nanoparticles in occupational settings. Objectives: The aim of this study was to identify potential cutaneous exposure scenarios at a workplace using engineered nanoparticles (alumina, ceria, amorphous silica) and evaluate the presence of these materials on workplace surfaces. Methods: Process review, workplace observations, and preliminary surface sampling were conducted using microvacuum and wipe sample collection methods and transmission electron microscopy with elemental analysis. Results: Exposure scenarios were identified with potential for incidental contact. Nanoparticles of silica or silica and/or alumina agglomerates (or aggregates) were identified in surface samples from work areas where engineered nanoparticles were used or handled. Conclusions: Additional data are needed to evaluate occupational exposures from skin contact with engineered nanoparticles; precautionary measures should be used to minimize potential cutaneous exposures in the workplace. PMID:25000112
[Disinfecting contact tonometers - a systematic review].
Neubauer, A S; Heeg, P; Kampik, A; Hirneiss, C
2009-05-01
The aim of this study is to provide the best available evidence on how to disinfect contact Goldman tonometers. A systematic review of all articles on disinfection of contact tonometers was conducted. Articles published up to July 2008 were identified in Medline, Embase and references from included articles. Two observers participated in the data retrieval and assessment of the studies identified. A total of 89 articles was retrieved, of which 58 could be included. Of those, 18 were clinical studies, 17 experimental microbiological studies, 8 expert assessments or guidelines and 15 reviews, surveys, descriptions of new methods. The clinical studies illustrate the importance of the problem, possible side effects of some disinfection methods but yield inconclusive results regarding efficacy. Experimental studies investigated a variety of bacterial and virological questions as well as material damage by disinfection. Both chlorine-based and hydrogen peroxide-based liquid disinfection were shown to be effective if applied for 5 min. Inconsistent results exist for alcohol wipes and UV disinfection - material damage has been described for both. The US guidelines and most expert recommendations are supported by evidence of the existing data. Chlorine-based and hydrogen peroxide-based liquid disinfections for 5 minutes are effective and relatively safe for disinfecting contact tonometers.
DOT National Transportation Integrated Search
1977-07-01
To study the national trend in alcohol-related crashes, a sample of 14 states was selected, and monthly accident data were collected for each state for the years 1965 through 1975. Surrogate measures for alcohol-related crashes were chosen on the bas...
Dismantling of the PETRA glove box: tritium contamination and inventory assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, R.
2015-03-15
The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followedmore » by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)« less
Forensic collection of trace chemicals from diverse surfaces with strippable coatings.
Jakubowski, Michael J; Beltis, Kevin J; Drennan, Paul M; Pindzola, Bradford A
2013-11-07
Surface sampling for chemical analysis plays a vital role in environmental monitoring, industrial hygiene, homeland security and forensics. The standard surface sampling tool, a simple cotton gauze pad, is failing to meet the needs of the community as analytical techniques become more sensitive and the variety of analytes increases. In previous work, we demonstrated the efficacy of non-destructive, conformal, spray-on strippable coatings for chemical collection from simple glass surfaces. Here we expand that work by presenting chemical collection at a low spiking level (0.1 g m(-2)) from a diverse array of common surfaces - painted metal, engineering plastics, painted wallboard and concrete - using strippable coatings. The collection efficiency of the strippable coatings is compared to and far exceeds gauze pads. Collection from concrete, a particular challenge for wipes like gauze, averaged 73% over eight chemically diverse compounds for the strippable coatings whereas gauze averaged 10%.
X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface
NASA Technical Reports Server (NTRS)
Wurth, Laura; Evans, Kurt; Weber, Bart; Headrick, Sarah
2005-01-01
With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.
Ondersma, Steven J; Beatty, Jessica R; Rosano, Thomas G; Strickler, Ronald C; Graham, Amy E; Sokol, Robert J
2016-01-02
Ethyl Glucoronide (EtG) and Ethyl Sulfate (EtS) have shown promise as biomarkers for alcohol and may be sensitive enough for use with pregnant women in whom even low-level alcohol use is important. However, there have been reports of over-sensitivity of EtG and EtS to incidental exposure to sources such as alcohol-based hand sanitizer. Further, few studies have evaluated these biomarkers among pregnant women, in whom the dynamics of these metabolites may differ. This study evaluated whether commercial EtG-EtS testing was vulnerable to high levels of environmental exposure to alcohol in pregnant women. Two separate samples of five nurses-one pregnant and the other postpartum, all of whom reported high levels of alcohol-based hand sanitizer use-provided urine samples before and 4-8 hours after rinsing with alcohol-based mouthwash and using hand sanitizer. The five pregnant nurses provided urine samples before, during, and after an 8-hour nursing shift, during which they repeatedly cleansed with alcohol-based hand sanitizer (mean 33.8 uses). The five postpartum nurses used hand sanitizer repeatedly between baseline and follow-up urine samples. No urine samples were positive for EtG-EtS at baseline or follow-up, despite use of mouthwash and-in the pregnant sample-heavy use of hand sanitizer (mean of 33.8 uses) throughout the 8-hour shift. Current, commercially available EtG-EtS testing does not appear vulnerable to even heavy exposure to incidental sources of alcohol among pregnant and postpartum women.
Exposure of Firefighters to Particulates and Polycyclic Aromatic Hydrocarbons
Baxter, C. Stuart; Hoffman, Joseph D.; Knipp, Michael J.; Reponen, Tiina; Haynes, Erin N.
2015-01-01
Firefighting continues to be among the most hazardous yet least studied occupations in terms of exposures and their relationship to occupational disease. Exposures are complex, involving mixtures of particles and chemicals such as polycyclic aromatic hydrocarbons (PAHs). Adverse health effects associated with these agents include elevated incidences of coronary heart disease and several cancers. PAHs have been detected at fire scenes, and in the firehouse rest area and kitchen, routinely adjoining the truck bay, and where firefighters spend a major part of each shift. An academic-community partnership was developed with the Cincinnati Fire Department with the goal of understanding active firefighters' airborne and dermal PAH exposure. PAHs were measured in air and particulates, and number and mass concentrations, respectively, of submicron (0.02–1 μm) and PM2.5 (2.5 μm diameter and less) particles during overhaul events in two firehouses and a University of Cincinnati administrative facility as a comparison location. During overhaul firefighters evaluate partially combusted materials for re-ignition after fire extinguishment and commonly remove Self-Contained Breathing Apparatus (SCBA). Face and neck wipes were also collected at a domestic fire scene. Overhaul air samples had higher mean concentrations of PM2.5 and submicron particles than those collected in the firehouse, principally in the truck bay and kitchen. Among the 17 PAHs analyzed, only naphthalene and acenaphthylene were generally detectable. Naphthalene was present in 7 out of 8 overhaul activities, in 2 out of 3 firehouse (kitchen and truck bay) samples, and in none collected from the control site. In firefighter face and neck wipes a greater number of PAHs were found, several of which have carcinogenic activity, such as benzofluoranthene, an agent also found in overhaul air samples. Although the concentration for naphthalene, and all other individual PAHs, was very low, the potential simultaneous exposure to multiple chemicals even in small quantities in combination with high ultrafine particle exposure deserves further study. It is recommended that personal respiratory and skin protection be worn throughout the overhaul process. PMID:24512044
Goldcamp, Michael J; Goldcamp, Diane M; Ashley, Kevin; Fernback, Joseph E; Agrawal, Anoop; Millson, Mark; Marlow, David; Harrison, Kenneth
2009-12-01
Beryllium exposure can cause a number of deleterious health effects, including beryllium sensitization and the potentially fatal chronic beryllium disease. Efficient methods for monitoring beryllium contamination in workplaces are valuable to help prevent dangerous exposures to this element. In this work, performance data on the extraction of beryllium from various size fractions of high-fired beryllium oxide (BeO) particles (from < 32 microm up to 212 microm) using dilute aqueous ammonium bifluoride (ABF) solution were obtained under various conditions. Beryllium concentrations were determined by fluorescence using a hydroxybenzoquinoline fluorophore. The effects of ABF concentration and volume, extraction temperature, sample tube types, and presence of filter or wipe media were examined. Three percent ABF extracts beryllium nearly twice as quickly as 1% ABF; extraction solution volume has minimal influence. Elevated temperatures increase the rate of extraction dramatically compared with room temperature extraction. Sample tubes with constricted tips yield poor extraction rates owing to the inability of the extraction medium to access the undissolved particles. The relative rates of extraction of Be from BeO of varying particle sizes were examined. Beryllium from BeO particles in fractions ranging from less than 32 microm up to 212 microm were subjected to various extraction schemes. The smallest BeO particles are extracted more quickly than the largest particles, although at 90 degrees C even the largest BeO particles reach nearly quantitative extraction within 4 hr in 3% ABF. Extraction from mixed cellulosic-ester filters, cellulosic surface-sampling filters, wetted cellulosic dust wipes, and cotton gloves yielded 90% or greater recoveries. Scanning electron microscopy of BeO particles, including partially dissolved particles, shows that dissolution in dilute ABF occurs not just on the exterior surface but also via accessing particles' interiors due to porosity of the BeO material. Comparison of dissolution kinetics data shows that as particle diameter approximately doubles, extraction time is increased by a factor of about 1.5, which is consistent with the influence of porosity on dissolution.
Comparison of Grab, Air, and Surface Results for Radiation Site Characterization
NASA Astrophysics Data System (ADS)
Glassford, Eric Keith
2011-12-01
The use of proper sampling methods and sample types for evaluating sites believed to be contaminated with radioactive materials is necessary to avoid misrepresenting conditions at the site. This study was designed to investigate if the site characterization, based upon uranium contamination measured in different types of samples, is dependent upon the mass of the sample collected. A bulk sample of potentially contaminated interior dirt was collected from an abandoned metal processing mill that rolled uranium between 1948 and 1956. The original mill dates from 1910 and has a dirt floor. The bulk sample was a mixture of dirt, black and yellow particles of metal dust, and small fragments of natural debris. Small mass (approximately 0.75 grams (g)) and large mass (approximately 70g) grab samples were prepared from the bulk sample material to simulate collection of a "grab" type sample. Air sampling was performed by re-suspending a portion of the bulk sample material using a vibration table to simulate airborne contamination that might be present during site remediation. Additionally, samples of removable contaminated surface dust were collected on 47 mm diameter filter paper by wiping the surfaces of the exposure chamber used to resuspend the bulk material. Certified reference materials, one containing a precisely known quantity of U 3O8 and one containing a known quantity of natural uranium, were utilized to calibrate the gamma spectrometry measurement system. Non-destructive gamma spectrometry measurements were used to determine the content of uranium-235 (235U) at 185 keV and 143 keV, thorium-234 (234Th) at 63 keV, and protactinium-234m (234mPa) at 1001 keV in each sample. Measurement of natural uranium in small, 1 g samples is usually accomplished by radiochemical analysis in order to measure alpha particles emitted by 238U, 235U, and 234U. However, uranium in larger bulk samples can also be measured non-destructively using gamma spectrometry to detect the low energy photons from 234Th and 234mPa, the short-lived decay products of 238U, and 235U. Two sided t-tests and coefficient of variation were used to compare sampling types. The large grab samples had the lowest calculated coefficient of variation results for activity and atom percentage. The wipe samples had the highest calculated coefficient of variation of mean specific activity (dis/sec/g) for all three energies. The air filter samples had the highest coefficient of variation calculation for mean atom percentage, for both uranium isotopes examined. The data indicated that the large mass sample was the most effective at characterizing the rolling mill radioactive site conditions, since this would indicate which samples had the smallest variations compared to the mean. Additionally, measurement results of natural uranium in the samples indicate that the distribution of radioactive contamination at the sampling location is most likely non-homogeneous and that the size of the sample collected and analyzed must be sufficiently large to insure that the analytical results are truly representative of the activity present.
McClure, Elizabeth M; Goldenberg, Robert L; Brandes, Neal; Darmstadt, Gary L; Wright, Linda L
2009-01-01
Of the 4 million neonatal deaths and 500,000 maternal deaths that occur annually worldwide, almost 99% are in developing countries and one-third are associated with infections. Implementation of proven interventions and targeted research on a select number of promising high-impact preventative and curative interventions are essential to achieve Millennium Development Goals for reduction of child and maternal mortality. Feasible, simple, low-cost interventions have the potential to significantly reduce the mortality and severe morbidity associated with infection in these settings. Studies of chlorhexidine in developing countries have focused on three primary uses: 1) intrapartum vaginal and neonatal wiping, 2) neonatal wiping alone, and 3) umbilical cord cleansing. A study of vaginal wiping and neonatal skin cleansing with chlorhexidine, conducted in Malawi in the 1990s suggested that chlorhexidine has potential to reduce neonatal infectious morbidity and mortality. A recent trial of cord cleansing conducted in Nepal also demonstrated benefit. Although studies have shown promise, widespread acceptance and implementation of chlorhexidine use has not yet occurred. This paper is derived in part from data presented at a conference on the use of chlorhexidine in developing countries and reviews the available evidence related to chlorhexidine use to reduce mortality and severe morbidity due to infections in mothers and neonates in low-resource settings. It also summarizes issues related to programmatic implementation. PMID:17399714
The prospective effects of impulsivity on alcohol and tobacco use in a college sample.
Doran, Neal; Trim, Ryan S
2013-01-01
Alcohol and tobacco use are strongly associated, particularly in younger populations, and concurrent use may encourage progression toward dependence on both substances. Impulsivity has been linked to the use of alcohol and tobacco individually, but has not been studied in terms of its association with use of both. This study tested the hypothesis that the effects of impulsivity (sensation seeking and negative urgency) on smoking initiation in a sample of college students (n = 400) would be mediated by alcohol consumption. We also predicted that sensation seeking and negative urgency would predict alcohol and cigarette use and overlap among initiators. Sensation seeking and negative urgency both predicted smoking initiation, but only the former effect was mediated by alcohol use. Among initiators, sensation seeking was associated with more frequent alcohol use as well as more frequent overlap between alcohol and tobacco use but not with smoking frequency. Higher negative urgency was associated with more frequent smoking, but not with alcohol use or alcohol/tobacco overlap. Findings are consistent with previous research in college samples and suggest the existence of multiple pathways to alcohol and tobacco use and co-use in college students.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaur, Manpreet, E-mail: manpreet.kaur@thapar.edu; Singh, Gaganjot; Bimbraw, Keshav
Nanostructured titania have been successfully synthesized by hydrolysis of alkoxide at calcination temperatures 500 °C, 600 °C and 700 °C. As the calcination temperature increases, alcohol washed samples show lesser rutile content as compared to water washed samples. Morphology and Particle sizes was determined by field emission scanning electron microscopy (FESEM), while thermogravimetric-differential scanning calorimetry (TG-DSC) was used to determine thermal stability. Alcohol washed samples undergo 30% weight loss whereas 16% in water washed samples was observed. The mean particle sizes were found to be increase from 37 nm to 100.9 nm and 35.3 nm to 55.2 nm for water and alcohol washed samplesmore » respectively. Hydrolysis of alkoxide was shown to be an effective means to prepare thermally stable titania by using alcohol washed samples as a precursor.« less
Abdullah, A F Lim; Miskelly, Gordon M
2010-04-15
Evaluation of the risk posed by contaminants present during and after decontamination of clandestine methamphetamine laboratories requires a connection between the levels of contaminants measured and those actually present at the scene. The recoveries of pseudoephedrine and methamphetamine from glass, stainless steel, and a range of impermeable surfaces likely to be found in a clandestine laboratory were examined, using GC-MS of derivatized samples as the analytical method. When surfaces had been cleaned prior to drug deposition, wiping with water-dampened filter paper can recover 60-80% of pseudoephedrine immediately after deposition, and at least 50% of the pseudoephedrine still present on a surface after 2 days when deposited at a surface concentration of 2.5 microg/100 cm(2). Wiping with methanol-dampened filter paper could recover 60-90% of the methamphetamine immediately after deposition, and could recover at least 50-60% of the methamphetamine still present after 2 days when 0.6 microg/100 cm(2) was initially deposited on the surface. Recoveries were lower for surfaces that had not been pre-cleaned. Methamphetamine and pseudoephedrine showed significant volatility in both the free base and hydrochloride forms, with experiments in an enclosed format showing up to half the recovered drug being present on a glass plate held about 4mm above a substrate contaminated with one of the drugs at the above surface concentrations after 2 days. It is therefore important to remove any visible bulk contaminants and remove obvious pseudoephedrine or methamphetamine-contaminated surfaces prior to heating, ventilation or sealing of a clandestine laboratory to avoid redistribution of material around the site. A revised method for pseudoephedrine analysis was developed that could also detect the pseudoephedrine-formaldehyde adduct that can form from trace pseudoephedrine present at clandestine laboratories. (c) 2009 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rinehart, R.; Almaguer, D.
1992-05-01
In response to a request from a management representative of the Kansas City, Kansas, Police Department (SIC-9221), an evaluation was undertaken of possible lead (7439921) exposures at the Police Department outdoor firing range. About 200,000 rounds of ammunition were fired at the range each year. Personal breathing zone and area air samples were taken for lead analysis. Surface wipe samples were taken as well along with hand lead concentrations and contamination of clothing. Air sampling revealed that the officers were exposed to 8 hour time weighted average concentrations of airborne lead ranging from nondetectable to 8 micrograms (microg) per cubicmore » meter. The general air samples collected ranged from nondetectable to trace levels of contamination. The authors conclude that airborne lead did not exceed evaluation criteria, but dermal, surface and clothing contamination could increase the potential for lead ingestion and lead contamination of automobiles and homes. The authors recommend that efforts be made to reduce the potential spread of lead, and that medical surveillance be instituted for frequent range users and the range master.« less
Lundin, Andreas; Mortensen, Laust Hvas; Halldin, Jan; Theobald, Holger
2015-07-01
The purpose of this study was to examine the effects of alcoholism, alcohol consumption amount, and alcohol consumption pattern on mortality in a general population sample. This study used a 1970 prospective population sample (double-phase random sample) of 2,300 individuals ages 18-65 years in Stockholm County, which was also linked to mortality registers. A total of 1,895 individuals participated in a semi-structured, baseline psychiatric interview with a psychiatrist and social worker. Alcoholism and other mental disorders were recorded according to the eighth revision of the International Classification of Diseases (ICD-8). Information on the usual amount and frequency of alcohol consumption was collected at the psychiatric interview. Mortality up to year 2011 was assessed with Cox proportional hazard regression models. At baseline, there were 65 men and 21 women diagnosed with alcoholism. During followup, there were 873 deaths in the study population of 1,895. Alcoholism was associated with increased mortality rate. Former drinkers, but not never-drinkers, also had increased risk for mortality compared with moderate drinkers. We found no associations between heavy consumption and mortality. Frequent heavy episodic drinking was uncommon but related to mortality before, but not after, adjusting for an alcoholism diagnosis. Our results demonstrated that alcoholism—but not a reported high consumption of alcohol or frequent heavy episodic drinking—predicted a long-term risk of death.
Lydon, David M.; Ram, Nilam; Conroy, David E.; Pincus, Aaron L.; Geier, Charles F.; Maggs, Jennifer L.
2016-01-01
Objective Despite evidence for detrimental effects of alcohol on sleep quality in laboratory studies, alcohol is commonly used as a self-prescribed sleep aid. This study examined the within-person associations of alcohol use with sleep duration and quality in everyday life to gain insight into the ecological validity of laboratory findings on the association between sleep and alcohol. Method A sample of 150 adults (age 19–89 years) were followed for 60+ days as part of an intensive experience sampling study wherein participants provided daily reports of their alcohol use, sleep duration, and sleep quality. Within-person and between-person associations of daily sleep duration and quality with alcohol use were examined using multilevel models. Results A significant, negative within-person association was observed between sleep quality and alcohol use. Sleep quality was lower on nights following alcohol use. Sleep duration did not vary as a function of within-person variation in alcohol use. Conclusions In line with laboratory assessments, alcohol use was associated with low sleep quality but was not associated with sleep duration, suggesting that laboratory findings generalize to everyday life. This examination of individuals’ daily lives suggests that alcohol does not systematically improve sleep quality or duration in real life. PMID:27249804
Pearson, Matthew R.; Henson, James M.
2013-01-01
Much research links impulsivity with alcohol use and problems. In two studies, unplanned (or impulsive) drinking is assessed directly to determine whether it has direct effects on alcohol use and alcohol-related problems. In study 1, we examined whether unplanned drinking serves as a proximal mediator of the effects of impulsivity-like traits on alcohol-related outcomes. With a sample of 211 college student drinkers, we found that the Unplanned Drinking Scale was significantly related to alcohol use, and perhaps more importantly, had a direct effect on alcohol-related problems even after controlling for frequency and quantity of alcohol use. Further, unplanned drinking partially mediated the effects of negative urgency on alcohol-related problems. In study 2, we examined whether unplanned drinking accounts for unique variance in alcohol-related outcomes when controlling for use of protective behavioral strategies. With a sample of 170 college students, we replicated the findings of Study 1 in that the Unplanned Drinking Scale had a significant direct effect on alcohol-related problems even after controlling for alcohol use; further, this effect was maintained when controlling for use of protective behavioral strategies. Limitations include the modest sample sizes and the cross-sectional design. Future directions for testing the Model of Unplanned Drinking Behavior are proposed. PMID:23276312
Zhang, Zhuomin; Ma, Yunjian; Wang, Qingtang; Chen, An; Pan, Zhuoyan; Li, Gongke
2013-05-17
A novel alumina nanowire (ANW) solid-phase microextraction (SPME) fiber coating was prepared by a simple and rapid anodization-chemical etching method for ultra-selective determination of volatile esters and alcohols from complicated food samples. Preparation conditions for ANW SPME fiber coating including corrosion solution concentration and corrosion time were optimized in detail for better surface morphology and higher surface area based on scanning electron microscope (SEM). Under the optimum conditions, homogeneous alumina nanowire structure of ANW SPME fiber coating was achieved with the average thickness of 20 μm around. Compared with most of commercial SPME fiber coatings, ANW SPME fiber coatings achieved the higher extraction capacity and special selectivity for volatile esters and alcohols. Finally, an efficient gas sampling technique based on ANW SPME fiber coating as the core was established and successfully applied for the ultra-selective determination of trace volatile esters and alcohols from complicated banana and fermented glutinous rice samples coupled with gas chromatography/mass spectrometry (GC/MS) detection. It was interesting that 25 esters and 2 alcohols among 30 banana volatile organic compounds (VOCs) identified and 4 esters and 7 alcohols among 13 identified VOCs of fermented glutinous rice were selectively sampled by ANW SPME fiber coatings. Furthermore, new analytical methods for the determination of some typical volatile esters and alcohols from banana and fermented glutinous rice samples at specific storage or brewing phases were developed and validated. Good recoveries for banana and fermented glutinous rice samples were achieved in range of 108-115% with relative standard deviations (RSDs) of 2.6-6.7% and 80.0-91.8% with RSDs of 0.3-1.3% (n=3), respectively. This work proposed a novel and efficient gas sampling technique of ANW SPME which was quite suitable for ultra-selectively sampling trace volatile esters and alcohols from complicated food samples. Copyright © 2013 Elsevier B.V. All rights reserved.
... Use the applicator brush attached to the bottle cap to apply ciclopirox topical solution evenly to all ... can reach these areas. Wipe off the bottle cap and neck and replace the cap tightly on ...
... instilling the next drop. Replace and tighten the cap on the dropper bottle. Do not wipe or ... someone else apply the gel. Remove the protective cap. Avoid touching the tip of the tube against ...
... your hands with soap and water. Dip a cotton swab into a skin-cleaning solution, such as ... or another antiseptic your provider recommends. Use the cotton swab to wipe and scrub around one pin ...
Illness transmission in the home: a possible role for alcohol-based hand gels.
Lee, Grace M; Salomon, Joshua A; Friedman, Jennifer F; Hibberd, Patricia L; Ross-Degnan, Dennis; Zasloff, Eva; Bediako, Sitso; Goldmann, Donald A
2005-04-01
The widespread use of child care has altered the epidemiology of respiratory and gastrointestinal (GI) infection in the community. Our primary objective was to measure transmission of respiratory and GI illnesses among families with children enrolled in child care. We also sought to examine potential predictors of reduced illness transmission in the home in a secondary analysis. We performed an observational, prospective cohort study to determine transmission rates for respiratory and GI illnesses within families with at least 1 child between 6 months and 5 years of age enrolled in child care. A survey about family beliefs and practices was mailed at the beginning of the study. Symptom diaries were provided for families to record the timing and duration of respiratory and GI illnesses. To ensure the accuracy of symptom diaries, biweekly telephone calls were performed to review illnesses recorded by participants. Families with > or =4 weeks of data recorded were included in the analysis. Families were recruited from 5 pediatric practices in the metropolitan Boston area. Of 261 families who agreed to participate in the study, 208 were available for analysis. Secondary transmission rates for respiratory and GI illnesses were measured as illnesses per susceptible person-month. We observed 1545 respiratory and 360 GI illnesses in 208 families from November 2000 to May 2001. Of these, 1099 (71%) respiratory and 297 (83%) GI illnesses were considered primary illnesses introduced into the home. The secondary transmission rates for respiratory and GI illnesses were 0.63 and 0.35 illnesses per susceptible person-month, respectively. Only two thirds of respondents correctly believed that contact transmission was important in the spread of colds, and fewer than half believed that it was important in the spread of stomach flus. Twenty-two percent of respondents reported use of alcohol-based hand gels all, most, or some of the time; 33% reported always washing their hands after blowing or wiping a nose. In multivariate models, use of alcohol-based hand gels had a protective effect against respiratory illness transmission in the home. In homes with young children enrolled in child care, illness transmission to family members occurs frequently. Alcohol-based hand gel use was associated with reduced respiratory illness transmission in the home.
27 CFR 6.95 - Consumer tasting or sampling at retail establishments.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Consumer tasting or sampling at retail establishments. 6.95 Section 6.95 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Exceptions § 6.95 Consumer tasting or sampling at retail establishments....
27 CFR 6.95 - Consumer tasting or sampling at retail establishments.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Consumer tasting or sampling at retail establishments. 6.95 Section 6.95 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Exceptions § 6.95 Consumer tasting or sampling at retail establishments....
Simons, Jeffrey S; Wills, Thomas A; Emery, Noah N; Marks, Russell M
2015-11-01
Research on alcohol use depends heavily on the validity of self-reported drinking. The present paper presents data from 647 days of self-monitoring with a transdermal alcohol sensor by 60 young adults. We utilized a biochemical measure, transdermal alcohol assessment with the WrisTAS, to examine the convergent validity of three approaches to collecting daily self-report drinking data: experience sampling, daily morning reports of the previous night, and 1-week timeline follow-back (TLFB) assessments. We tested associations between three pharmacokinetic indices (peak concentration, area under the curve (AUC), and time to reach peak concentration) derived from the transdermal alcohol signal and within- and between- person variation in alcohol dependence symptoms. The WrisTAS data corroborated 85.74% of self-reported drinking days based on the experience sampling data. The TLFB assessment and combined experience sampling and morning reports agreed on 87.27% of drinking days. Drinks per drinking day did not vary as a function of wearing or not wearing the sensor; this indicates that participants provided consistent reports of their drinking regardless of biochemical verification. In respect to self-reported alcohol dependence symptoms, the AUC of the WrisTAS alcohol signal was associated with dependence symptoms at both the within- and between- person level. Furthermore, alcohol dependence symptoms at baseline predicted drinking episodes characterized in biochemical data by both higher peak alcohol concentration and faster time to reach peak concentration. The results support the validity of self-report alcohol data, provide empirical data useful for optimal design of daily process sampling, and provide an initial demonstration of the use of transdermal alcohol assessment to characterize drinking dynamics associated with risk for alcohol dependence. Copyright © 2015 Elsevier Ltd. All rights reserved.
Simons, Jeffrey S.; Wills, Thomas A.; Emery, Noah N.; Marks, Russell M.
2015-01-01
Research on alcohol use depends heavily on the validity of self-reported drinking. The present paper presents data from 647 days of self-monitoring with a transdermal alcohol sensor by 60 young adults. We utilized a bio chemical measure, transdermal alcohol assessment with the WrisTAS, to examine the convergent validity of three approaches to collecting daily self-report drinking data: experience sampling, daily morning reports of the previous night, and 1-week timeline follow-back (TLFB) assessments. We tested associations between three pharmacokinetic indices (peak concentration, area under the curve (AUC), and time to reach peak concentration) derived from the transdermal alcohol signal and within- and between-person variation in alcohol dependence symptoms. The WrisTAS data corroborated 85.74% of self-reported drinking days based on the experience sampling data. The TLFB assessment and combined experience sampling and morning reports agreed on 87.27% of drinking days. Drinks per drinking day did not vary as a function of wearing or not wearing the sensor; this indicates that participants provided consistent reports of their drinking regardless of biochemical verification. In respect to self-reported alcohol dependence symptoms, the AUC of the WrisTAS alcohol signal was associated with dependence symptoms at both the within- and between-person level. Furthermore, alcohol dependence symptoms at baseline predicted drinking episodes characterized in biochemical data by both higher peak alcohol concentration and faster time to reach peak concentration. The results support the validity of self-report alcohol data, provide empirical data useful for optimal design of daily process sampling, and provide an initial demon stration of the use of transdermal alcohol assessment to characterize drinking dynamics associated with risk for alcohol dependence. PMID:26160523
Yonamine, Mauricio; Sanches, Livia Rentas; Paranhos, Beatriz Aparecida Passos Bismara; de Almeida, Rafael Menck; Andreuccetti, Gabriel; Leyton, Vilma
2013-01-01
Alcohol and drug use by truck drivers is a current problem in Brazil. Though there is evidence that alcohol consumption is occurring in higher proportions, the use of stimulant drugs to avoid fatigue and to maintain the work schedule has also been reported. The purpose of this study was to estimate the incidence of alcohol and illicit drug use among truck drivers on São Paulo state roads. São Paulo is the most populous state in Brazil and has the largest industrial park and economic production in the country. Data were assessed not only using a questionnaire but also, and more reliably, through toxicological analysis of oral fluid samples. Between the years 2002 and 2008, 1250 oral fluid samples were collected from truck drivers on the roads during morning hours. The samples were tested for the presence of alcohol, cocaine, tetrahydrocannabinol (THC), and amphetamine/methamphetamine. A previously published, validated gas chromatographic (gas chromatography-flame ionization detection and gas chromatography-mass spectrometry) method was applied to the samples for alcohol and drug detection. Of the total analyzed samples, 3.1 percent (n = 39) were positive: 1.44 percent (n = 18) were positive for alcohol, 0.64 percent (n = 8) for amphetamines, 0.56 percent (n = 7) for cocaine, and 0.40 percent (n = 5) for THC. In one case, cocaine and THC were detected. The results are indicative of the extent of alcohol and drug use by truck drivers in the state of São Paulo, Brazil. This research provides evidence that not only alcohol but also illicit drug use is a real problem among professional drivers. The use of these substances should be controlled to better promote safe driving conditions on Brazilian roads.
... injuries are things like fractures , sprains and strains , concussions , and cuts . They usually happen after a blow or force — like getting tackled in football or wiping out while skateboarding. Overuse injuries include ...
... wipe furniture. Rug Deodorizer Liberally sprinkle carpets with baking soda. Wait at least 15 minutes and vacuum. ... with one teaspoon of salt, one teaspoon of baking soda and a sheet of aluminum foil. Totally ...
... insert your catheter: Wash your hands well with soap and water. Collect your supplies, including your catheter ( ... penis with Betadine (an antiseptic cleaner), a towelette, soap and water, or baby wipes the way your ...
Demographic Predictors of Event-Level Associations between Alcohol Consumption and Sexual Behavior.
Wells, Brooke E; Rendina, H Jonathon; Kelly, Brian C; Golub, Sarit A; Parsons, Jeffrey T
2016-02-01
Alcohol consumption is associated with sexual behavior and outcomes, though research indicates a variety of moderating factors, including demographic characteristics. To better target interventions aimed at alcohol-related sexual risk behavior, our analyses simultaneously examine demographic predictors of both day- and event-level associations between alcohol consumption and sexual behavior in a sample of young adults (N = 301) who are sexually active and consume alcohol. Young adults (aged 18-29) recruited using time-space sampling and incentivized snowball sampling completed a survey and a timeline follow-back calendar reporting alcohol consumption and sexual behavior in the past 30 days. On a given day, a greater number of drinks consumed was associated with higher likelihood of sex occurring, particularly for women and single participants. During a given sexual event, number of drinks consumed was not associated with condom use, nor did any demographic predictors predict that association. Findings highlight associations between alcohol and sexual behavior, though not between alcohol and sexual risk behavior, highlighting the need for additional research exploring the complex role of alcohol in sexual risk behavior and the need to develop prevention efforts to minimize the role of alcohol in the initiation of sexual encounters.
Increased alcohol use in a treatment sample of Oklahoma City bombing victims.
Pfefferbaum, B; Doughty, D E
2001-01-01
Research examining alcohol use in disaster victims has yielded conflicting results. This study of 43 acknowledged alcohol users, taken from a nonrandom volunteer sample of Oklahoma City bombing victims receiving support services, revealed relationships between increased alcohol use and a number of variables--injury, retrospectively reported initial reaction to the explosion, grief, and posttraumatic stress symptomatology. The findings suggest that if alcohol use was motivated by an attempt to alleviate symptoms, it was not effective, as evidenced by an association between increased alcohol use and functional impairment. Increased alcohol consumption may present a problem in disaster victims months after exposure to trauma. Therefore, the use of alcohol should be routinely assessed in those who remain symptomatic over time.
Durbeej, Natalie; Elgán, Tobias H; Jalling, Camilla; Gripenberg, Johanna
2017-01-01
Alcohol use and alcohol-related problems, including accidents, vandalism and violence, at sporting events are of increased concern in Sweden and other countries. The relationship between alcohol use and violence has been established and can be explained by the level of intoxication. Given the occurrence of alcohol use and alcohol-related problems at sporting events, research has assessed intoxication levels measured through biological sampling among spectators. This cross-sectional study aimed to assess the level of alcohol intoxication among spectators at football matches in the Swedish Premier Football League. Spectators were randomly selected and invited to participate in the study. Alcohol intoxication was measured with a breath analyser for Blood Alcohol Concentration levels, and data on gender, age, and recent alcohol use were gathered through a face-to-face interview. Blood Alcohol Concentration samples from 4420 spectators were collected. Almost half (46.8%) had a positive Blood Alcohol Concentration level, with a mean value of 0.063%, while 8.9% had a Blood Alcohol Concentration level ≥ 0.1%, with a mean value of 0.135%. Factors that predicted a higher Blood Alcohol Concentration level included male gender (p = 0.005), lower age (p < 0.001), attending a local derby (p < 0.001), alcohol use prior to having entered the arena (p < 0.001), attending a weekend match (p < 0.001), and being a spectator at supporter sections (p < 0.001). About half of all spectators at football matches in the Swedish Premier Football League drink alcohol in conjunction with the match. Approximately one tenth have a high level of alcohol intoxication.
Edvardsen, Hilde Marie Erøy; Karinen, Ritva; Moan, Inger Synnøve; Oiestad, Elisabeth Leere; Christophersen, Asbjørg Solberg; Gjerde, Hallvard
2014-03-10
Working under the influence of drugs and/or alcohol may affect safety and job performance. However, the size of this possible problem among health professionals (HPs) is unknown. The aim of this study was threefold: (i) to analyze samples of oral fluid and self-reported data from questionnaires to investigate the prevalence of alcohol and drugs among a sample of HPs in Norway, (ii) to study self-reported absence from or impairment at work due to alcohol and/or drug use, and (iii) to examine whether such use and absence/impairment due to such use depend on socio-demographic variables.A total of 916 of the 933 invited HPs from hospitals and pharmacies participated in the study (participation rate = 98.2%), and 81.1% were women. Associations were analyzed in bi-variate cross tables with Chi-square statistics to assess statistical significance.Alcohol was not detected in any of the samples. Ethyl glucuronide, a specific alcohol metabolite, was found in 0.3% of the collected samples. Illicit drugs and medicinal drugs were identified in 0.6% and 7.3% of the samples, respectively. Both analytical results and self-reported use of alcohol and drugs during the past 12 months indicate that recent and past year alcohol and drug use was lower among HPs than among workers in other business areas in Norway, Europe and US. Nevertheless, several HPs reported absence from work due to alcohol (0.9%) and medicinal drug use (0.8%) during the past 12 months. A substantial part (16.7%) of the self-reported medicinal drug users reported absence from work because of use of medicinal drugs during the past 12 months, and more than 1/4 of those reported in-efficiency at work because of the use of medicinal drugs during the past 12 months. Reduced efficiency at work due to alcohol use during the past 12 months was reported by 12.2%.This sample of HPs seldom used illicit drugs, few had a high level of alcohol consumption, and few tested positive for medicinal drugs. Absence or hangover related to the use of medicinal drugs or alcohol appeared to be a bigger issue than the acute intoxication or the use of illicit drugs.
Pirbuterol Acetate Oral Inhalation
... Pirbuterol is in a class of medications called beta-agonist bronchodilators. It works by relaxing and opening ... cleaning. Once a week, remove the mouthpiece cover, turn the inhaler upside down and wipe the mouthpiece ...
Hydrocortisone, Neomycin, and Polymyxin
... your pharmacist or doctor. Replace and tighten the cap or dropper right away. Wash your hands to ... instilling the next drop. Replace and tighten the cap on the dropper bottle. Do not wipe or ...
Parental bonding in men with alcohol disorders: a relationship with conduct disorder.
Joyce, P R; Sellman, D; Wells, E; Frampton, C M; Bushnell, J A; Oakley-Browne, M; Hornblow, A R
1994-09-01
Men from a clinical treatment setting suffering from alcohol dependence, and randomly selected men from the community diagnosed as having alcohol abuse and/or dependence, completed the Parental Bonding Instrument. The men from the alcohol treatment setting perceived both parents as having been uncaring and overprotective. In the general population sample, an uncaring and overprotective parental style was strongly associated with childhood conduct disorder, but not with alcohol disorder symptoms. This discrepancy in perceived parenting highlights the difficulties in extrapolating findings about aetiological factors for alcohol disorders from clinical samples. It also suggests that childhood conduct disorder and adult antisocial behaviour could influence which men with alcohol disorders receive inpatient treatment.
Livingston, Michael; Dietze, Paul; Ferris, Jason; Pennay, Darren; Hayes, Linda; Lenton, Simon
2013-03-16
Telephone surveys based on samples of landline telephone numbers are widely used to measure the prevalence of health risk behaviours such as smoking, drug use and alcohol consumption. An increasing number of households are relying solely on mobile telephones, creating a potential bias for population estimates derived from landline-based sampling frames which do not incorporate mobile phone numbers. Studies in the US have identified significant differences between landline and mobile telephone users in smoking and alcohol consumption, but there has been little work in other settings or focussed on illicit drugs. This study examined Australian prevalence estimates of cannabis use, tobacco smoking and risky alcohol consumption based on samples selected using a dual-frame (mobile and landline) approach. Respondents from the landline sample were compared both to the overall mobile sample (including respondents who had access to a landline) and specifically to respondents who lived in mobile-only households. Bivariate comparisons were complemented with multivariate logistic regression models, controlling for the effects of basic demographic variables. The landline sample reported much lower prevalence of tobacco use, cannabis use and alcohol consumption than the mobile samples. Once demographic variables were adjusted for, there were no significant differences between the landline and mobile respondents on any of the alcohol measures examined. In contrast, the mobile samples had significantly higher rates of cannabis and tobacco use, even after adjustment. Weighted estimates from the dual-frame sample were generally higher than the landline sample across all substances, but only significantly higher for tobacco use. Landline telephone surveys in Australia are likely to substantially underestimate the prevalence of tobacco smoking by excluding potential respondents who live in mobile-only households. In contrast, estimates of alcohol consumption and cannabis use from landline surveys are likely to be broadly accurate, once basic demographic weighting is undertaken.
Zhang, Melvyn W. B.; Tran, Bach Xuan; Le, Huong Thi; Long, Nguyen Hoang; Le, Huong Thi; Hinh, Nguyen Duc; Tho, Tran Dinh; Le, Bao Nguyen; Thuc, Vu Thi Minh; Ngo, Chau; Tu, Nguyen Huu; Latkin, Carl A.; Ho, Roger CM
2017-01-01
Objectives The average alcohol consumption per capita among Vietnamese adults has consistently increased. Although alcohol-related disorders have been extensively studied, there is a paucity of research shedding light on this issue among Internet users. The study aimed to examine the severity of alcohol-related disorders and other associated factors that might predispose individuals towards alcohol usage in a sample of youths recruited online. Methods An online cross-sectional study was conducted with 1,080 Vietnamese youths. A standardized questionnaire was used. Respondent-driven sampling was applied to recruit participants. Multivariate logistic and Tobit regressions were utilized to identify the associated factors. Results About 59.5% of the males and 12.7% of the total youths declared that they were actively using alcohol. From the total sample, a cumulative total of 32.3% of the participants were drinking alcohol, with 21.8% and 25.0% of the participants being classified as drinking hazardously and binge drinkers, respectively. The majority of the participants (60.7%) were in the pre-contemplative stage. Conclusions A high prevalence of hazardous drinking was recognized among online Vietnamese youths. In addition, we found relationships between alcohol use disorder and other addictive disorders, such as tobacco smoking and water-pipe usage. Our results highlighted that the majority of the individuals are not receptive to the idea of changing their alcohol habits, and this would imply that there ought to be more government effort towards the implementation of effective alcohol control policies. PMID:28523209
Unrecorded alcohol consumption in Russia: toxic denaturants and disinfectants pose additional risks
Solodun, Yuriy V.; Monakhova, Yulia B.; Kuballa, Thomas; Samokhvalov, Andriy V.; Rehm, Jürgen; Lachenmeier, Dirk W.
2011-01-01
In 2005, 30% of all alcohol consumption in Russia was unrecorded. This paper describes the chemical composition of unrecorded and low cost alcohol, including a toxicological evaluation. Alcohol products (n=22) from both recorded and unrecorded sources were obtained from three Russian cities (Saratov, Lipetsk and Irkutsk) and were chemically analyzed. Unrecorded alcohols included homemade samogons, medicinal alcohols and surrogate alcohols. Analysis included alcoholic strength, levels of volatile compounds (methanol, acetaldehyde, higher alcohols), ethyl carbamate, diethyl phthalate (DEP) and polyhexamethyleneguanidine hydrochloride (PHMG). Single samples showed contamination with DEP (275–1269 mg/l) and PHMG (515 mg/l) above levels of toxicological concern. Our detailed chemical analysis of Russian alcohols showed that the composition of vodka, samogon and medicinal alcohols generally did not raise major public health concerns other than for ethanol. It was shown, however, that concentration levels of DEP and PHMG in some surrogate alcohols make these samples unfit for human consumption as even moderate drinking would exceed acceptable daily intakes. PMID:22319254
Unrecorded alcohol consumption in Russia: toxic denaturants and disinfectants pose additional risks.
Solodun, Yuriy V; Monakhova, Yulia B; Kuballa, Thomas; Samokhvalov, Andriy V; Rehm, Jürgen; Lachenmeier, Dirk W
2011-12-01
In 2005, 30% of all alcohol consumption in Russia was unrecorded. This paper describes the chemical composition of unrecorded and low cost alcohol, including a toxicological evaluation. Alcohol products (n=22) from both recorded and unrecorded sources were obtained from three Russian cities (Saratov, Lipetsk and Irkutsk) and were chemically analyzed. Unrecorded alcohols included homemade samogons, medicinal alcohols and surrogate alcohols. Analysis included alcoholic strength, levels of volatile compounds (methanol, acetaldehyde, higher alcohols), ethyl carbamate, diethyl phthalate (DEP) and polyhexamethyleneguanidine hydrochloride (PHMG). Single samples showed contamination with DEP (275-1269 mg/l) and PHMG (515 mg/l) above levels of toxicological concern. Our detailed chemical analysis of Russian alcohols showed that the composition of vodka, samogon and medicinal alcohols generally did not raise major public health concerns other than for ethanol. It was shown, however, that concentration levels of DEP and PHMG in some surrogate alcohols make these samples unfit for human consumption as even moderate drinking would exceed acceptable daily intakes.
The relation of personality to alcohol abuse/dependence in a high-risk sample.
Loukas, A; Krull, J L; Chassin, L; Carle, A C
2000-12-01
The current study had two goals. The first goal was to test the mediational role of young adult personality in the relation between parental alcoholism and young adult alcoholism. The second was to examine the associations between personality and alcohol use motives and reasons to limit drinking in order to explore possible mechanisms by which personality may influence alcohol abuse/dependence. Multilevel modeling techniques were used to analyze data obtained from a community sample of young adult children of alcoholics and demographically matched controls. Results revealed that young adult neuroticism and agreeableness each, in part, mediated the effect of parental alcoholism on young adult alcoholism. Moreover, individuals high in neuloticism reported stronger coping motives to use alcohol, individuals low in agreeableness reported stronger coping motives and weaker upbringing reasons to limit drinking, and individuals low in conscientiousness reported stronger coping and enhancement motives to use alcohol, and weaker performance reasons to limit drinking.
Leitz, Jenny; Kuballa, Thomas; Rehm, Jürgen; Lachenmeier, Dirk W.
2009-01-01
Background Phthalates are synthetic compounds with a widespread field of applications. For example, they are used as plasticizers in PVC plastics and food packaging, or are added to personal care products. Diethyl phthalate (DEP) may be used to denature alcohol, e.g., for cosmetic purposes. Public health concerns of phthalates include carcinogenic, teratogenic, hepatotoxic and endocrine effects. The aim of this study was to develop and validate a method for determining phthalates in alcohol samples and to provide a risk assessment for consumers of such products. Methodology/Principal Findings A liquid-liquid extraction procedure was optimized by varying the following parameters: type of extraction solvent (cyclohexane, n-hexane, 1,1,2-trichlorotrifluoroethane), the ratio extraction solvent/sample volume (1∶1 to 50∶1) and the number of extraction repetitions (1–10). The best extraction yield (99.9%) was achieved with the solvent 1,1,2-trichlorotrifluoroethane, an extraction solvent volume/sample volume ratio of 10∶1 and a double extraction. For quantification, gas chromatography/mass spectrometry with deuterated internal standards was used. The investigated samples were alcoholic beverages and unrecorded alcohol products from different countries (n = 257). Two unrecorded alcohol samples from Lithuania contained diethyl phthalate in concentrations of 608 mg/L and 210 mg/L. Conclusions/Significance The consumption of the phthalate-positive unrecorded alcohols would exceed tolerable daily intakes as derived from animal experiments. Both positive samples were labelled as cosmetic alcohol, but had clearly been offered for human consumption. DEP seems to be unsuitable as a denaturing agent as it has no effect on the organoleptic properties of ethanol. In light of our results that DEP might be consumed by humans in unrecorded alcohols, the prohibition of its use as a denaturing agent should be considered. PMID:19956573
Alcohol use in the military: associations with health and wellbeing.
Waller, Michael; McGuire, Annabel C L; Dobson, Annette J
2015-07-28
This study assessed the extent to which alcohol consumption in a military group differed from the general population, and how alcohol affected the military group's health and social functioning. A cross sectional survey of military personnel (n = 5311) collected self-reported data on alcohol use (AUDIT scale) and general health, role limitations because of physical health problems (role physical), and social functioning scores (SF36 subscales). Logistic regression was used to compare drinking behaviours between the military sample and a general population sample, using the categories risky drinkers (>2 units per day), low risk drinkers (≤2 standard drinks per day) and abstainers. Groups in the military sample with the highest levels of alcohol misuse (harmful drinking AUDIT ≥ 16, alcohol dependence AUDIT ≥ 20, and binge drinking) were also identified. Linear regression models were then used to assess the association between alcohol misuse and SF36 scores. There were fewer risky drinkers in the military sample than in the general population sample. There were also fewer abstainers, but more people who drank at a lower risk level (≤2 standard drinks per day), than in a sample of the general population. Harmful drinking and alcohol dependence were most commonly observed in men, younger age groups, non-commissioned officers and lower ranks as well as reserve and ex-serving groups. Alcohol misuse was clearly associated with poorer general health scores, more role limitations because of physical health problems, and lower social functioning. Although risky drinking was lower in the military group than in the general population, drinking was associated with poorer health, more limitations because of physical health problems, and poorer social functioning in Defence members. These results highlight the potential benefits for Defence forces in reducing alcohol use among members, in both those groups identified at highest risk, and across the military workforce as a whole.
The alcohol purchase task in young men from the general population.
Bertholet, Nicolas; Murphy, James G; Daeppen, Jean-Bernard; Gmel, Gerhard; Gaume, Jacques
2015-01-01
The alcohol purchase task (APT), which presents a scenario and asks participants how many drinks they would purchase and consume at different prices, has been used among students and small clinical samples to obtain measures of alcohol demand but not in large, general population samples. We administered the APT to a large sample of young men from the general population (Cohort Study on Substance Use Risk Factors). Participants who reported drinking in the past year (n=4790), reported on past 12 months alcohol use, on DSM-5 alcohol use disorder (AUD) criteria and on alcohol related consequences were included. Among the APT's demand parameters, intensity was 8.7 (SD=6.5) indicating that, when drinks are free, participants report a planned consumption of almost 9 drinks. The maximum alcohol expenditure (Omax) was over 35CHF (1CHF=1.1USD) and the demand became elastic (Pmax) at 8.4CHF (SD=5.6). The mean price at which the consumption was suppressed was 15.6CHF (SD=5.4). Exponential equation provided a satisfactory fit to individual responses (mean R(2): 0.8, median: 0.8). Demand intensity was correlated with alcohol use, number of AUD criteria and number of consequences (all r≥0.3, p<0.0001). Omax was correlated with alcohol use (p<0.0001). The elasticity parameter was weakly correlated with alcohol use in the expected direction. The APT measures are useful in characterizing demand for alcohol in young men in the general population. Demand may provide a clinically useful index of strength of motivation for alcohol use in general population samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Cognitive representations of AIDS: a phenomenological study.
Anderson, Elizabeth H; Spencer, Margaret Hull
2002-12-01
Cognitive representations of illness determine behavior. How persons living with AIDS image their disease might be key to understanding medication adherence and other health behaviors. The authors' purpose was to describe AIDS patients' cognitive representations of their illness. A purposive sample of 58 men and women with AIDS were interviewed. Using Colaizzi's (1978) phenomenological method, rigor was established through application of verification, validation, and validity. From 175 significant statements, 11 themes emerged. Cognitive representations included imaging AIDS as death, bodily destruction, and just a disease. Coping focused on wiping AIDS out of the mind, hoping for the right drug, and caring for oneself. Inquiring about a patient's image of AIDS might help nurses assess coping processes and enhance nurse-patient relationships.
Cranford, James A.; Zucker, Robert A.; Jester, Jennifer M.; Puttler, Leon I.; Fitzgerald, Hiram E.
2010-01-01
Current models of adolescent drinking behavior hypothesize that alcohol expectancies mediate the effects of other proximal and distal risk factors. This longitudinal study tested the hypothesis that the effects of parental alcohol involvement on their children’s drinking behavior in mid-adolescence are mediated by the children’s alcohol expectancies in early adolescence. A sample of 148 initially 9–11 year old boys and their parents from a high-risk population and a contrast group of community families completed measures of drinking behavior and alcohol expectancies over a 6-year interval. We analyzed data from middle childhood (M age = 10.4 years), early adolescence (M age = 13.5 years), and mid-adolescence (M age = 16.5 years). The sample was restricted only to adolescents who had begun to drink by mid-adolescence. Results from zero-inflated Poisson regression analyses showed that 1) maternal drinking during their children’s middle childhood predicted number of drinking days in middle adolescence; 2) negative and positive alcohol expectancies in early adolescence predicted odds of any intoxication in middle adolescence; and 3) paternal alcoholism during their children’s middle childhood and adolescents’ alcohol expectancies in early adolescence predicted frequency of intoxication in middle adolescence. Contrary to predictions, child alcohol expectancies did not mediate the effects of parental alcohol involvement in this high-risk sample. Different aspects of parental alcohol involvement, along with early adolescent alcohol expectancies, independently predicted adolescent drinking behavior in middle adolescence. Alternative pathways for the influence of maternal and paternal alcohol involvement and implications for expectancy models of adolescent drinking behavior were discussed. PMID:20853923
Newman, Ian; Qian, Ling; Tamrakar, Niran; Feng, Yonghua; Xu, Ganrong
2017-01-01
Unrecorded traditional distilled spirits (bai jiu, ) are made and used throughout rural China for everyday use and special occasions. Nearly every town or village has a distiller to supply the demand. In rural China, distilling bai jiu is legal and regulated lightly or not at all. The World Health Organization estimates that as much as 25% of all alcohol consumed in China is unrecorded alcohol, of which an unknown portion is unrecorded bai jiu. Little is known about the composition of unrecorded Chinese spirits from rural parts of the country. This study focused on white spirits because the high ethanol (EtOH) concentration makes them more likely to contribute to health risks compared to other types of lower alcohol by volume (ABV) Chinese unrecorded alcohol. Researchers purchased samples of Chinese white spirits from small-factory distillers in central China. An independent laboratory conducted the analysis. Alcohol strength (ABV) was determined by hydrometer. Gas chromatography was used to determine the concentration of volatile organic compounds: EtOH, methanol, acetaldehyde, ethyl acetate, and higher alcohols. Samples were tested for 3 heavy metals-arsenic, cadmium, and lead. We used the guidelines developed by the Alcohol Measures for Public Health Research Alliance (AMPHORA) of the European Commission to assess risk. ABV ranged from 35.7 to 61.4%, and 58 of the 61 samples exceeded 40% ABV. The concentration of methanol, ethyl acetate, lead, arsenic, and cadmium was below AMPHORA guideline. The sum of higher alcohols exceeded the AMPHORA maximum in just 1 sample. Forty of the 61 samples had acetaldehyde levels beyond the AMPHORA guideline. The unrecorded Chinese alcohols we analyzed had a high EtOH concentration-a public health concern that is also presented by recorded alcohols. The high percentage of samples (65.5%) that had elevated acetaldehyde suggests the need to investigate the causes for this result and the need for steps to reduce acetaldehyde levels. The cumulative long-term risks of using high EtOH and high acetaldehyde Chinese spirits are heightened by the percentage of people in China who have a genetic trait for impaired acetaldehyde metabolism. Copyright © 2016 The Authors. Alcoholism: Clinical and Experimental Research published by Wiley Periodicals, Inc. on behalf of Research Society on Alcoholism.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Samples. 26.209 Section 26.209 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Samples. 26.209 Section 26.209 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Samples. 26.43 Section 26.43 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Samples. 26.209 Section 26.209 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Samples. 26.43 Section 26.43 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Samples. 26.43 Section 26.43 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Products Coming Into the...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Samples. 24.82 Section 24.82 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE... vinegar and salted wine as defined in § 24.215, the proprietor shall submit under separate cover at the...
Coskunpinar, Ayca; Cyders, Melissa A
2012-07-01
The goal of the current study is to examine how urgency, drinking motives, and risk/benefit perception concurrently influence problematic alcohol consumption in young adults. Participants were 281 young adults enrolled in large, public US mid-western university. The mean age of the sample was 19.81 (SD=1.82) and 79.7% of the sample was female and 84.7% of the sample was Caucasian. A series of moderated-mediation analyses indicated the following: The relationship between negative urgency and alcohol use was mediated through coping motives, and this relationship between coping motives and alcohol use was moderated by benefit perception. The relationship between positive urgency and alcohol use was mediated through enhancement motives, and this relationship between enhancement motives and alcohol use was moderated by benefit perception. This study suggests that modifying perceptions about the benefits of alcohol and drinking motives could be viable prevention and/or treatment strategy in this population, especially among those who exhibit urgent behaviors. Published by Elsevier Ltd.
The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.
Strawsine, Ellen; Lutmer, Brian
2017-11-16
This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.
Kim, Jueun; Park, Aesoon; Glatt, Stephen J; Eckert, Tanya L; Vanable, Peter A; Scott-Sheldon, Lori A J; Carey, Kate B; Ewart, Craig K; Carey, Michael P
2015-02-01
To investigate whether the effects of family conflict on adolescent drinking differed as a function of 5-hydroxy tryptamine transporter-linked polymorphic region (5-HTTLPR) genotype cross-sectionally and prospectively in two independent samples of adolescents. Path analysis and multi-group analysis of two prospective datasets were conducted. United States and United Kingdom. Sample 1 was 175 adolescents in the United States (mean age = 15 at times 1 and 2 with a 6-month interval); Sample 2 was 4916 adolescents in the United Kingdon (mean age = 12 at time 1 and 15 at time 2). In both samples, demographics, tri-allelic 5-HTTLPR genotype and perceived family conflict were assessed at time 1. Alcohol use (frequency of drinking) and alcohol misuse (frequency of intoxication, frequency of drinking three or more drinks, maximum number of drinks) were assessed at times 1 and 2. A significant gene-environment interaction on alcohol misuse at time 1 was found in both sample 1 (β = 0.57, P = 0.001) and sample 2 (β = 0.19, P = 0.01), indicating that the 5-HTTLPR low-activity allele carriers exposed to higher levels of family conflict were more likely to engage in alcohol misuse than non-carriers. A significant gene-environment interaction effect on change in alcohol misuse over time was found only in sample 1 (β = 0.48, P = 0.04) but not in sample 2. Compared with non-carriers, adolescents carrying the 5-HTTLPR low-activity allele are more susceptible to the effects of family conflict on alcohol misuse. © 2014 Society for the Study of Addiction.
Food Safety While Hiking, Camping and Boating
... list. Carry items like dried pasta, rice, and baking mixes in plastic bags and take only the ... away from fresh water. Some wilderness campers use baking soda to wash their utensils. Pack disposable wipes ...
Peripherally inserted central catheter - dressing change
... chlorhexidine) in a single-use small applicator Special sponges or wipes that contain a cleaning agent, such ... Clean your skin around the site with the sponge and cleaning solution for 30 seconds. Let the ...
A computational model for doctoring fluid films in gravure printing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hariprasad, Daniel S., E-mail: dshari@unm.edu; Grau, Gerd; Schunk, P. Randall
2016-04-07
The wiping, or doctoring, process in gravure printing presents a fundamental barrier to resolving the micron-sized features desired in printed electronics applications. This barrier starts with the residual fluid film left behind after wiping, and its importance grows as feature sizes are reduced, especially as the feature size approaches the thickness of the residual fluid film. In this work, various mechanical complexities are considered in a computational model developed to predict the residual fluid film thickness. Lubrication models alone are inadequate, and deformation of the doctor blade body together with elastohydrodynamic lubrication must be considered to make the model predictivemore » of experimental trends. Moreover, model results demonstrate that the particular form of the wetted region of the blade has a significant impact on the model's ability to reproduce experimental measurements.« less
Contamination removal using various solvents and methodologies
NASA Technical Reports Server (NTRS)
Jeppsen, J. C.
1989-01-01
Critical and non-critical bonding surfaces must be kept free of contamination that may cause potential unbonds. For example, an aft-dome section of a redesigned solid rocket motor that had been contaminated with hydraulic oil did not appear to be sufficiently cleaned when inspected by the optically stimulated electron emission process (Con Scan) after it had been cleaned using a hand double wipe cleaning method. As a result, current and new cleaning methodologies as well as solvent capability in removing various contaminant materials were reviewed and testing was performed. Bonding studies were also done to verify that the cleaning methods used in removing contaminants provide an acceptable bonding surface. The removal of contaminants from a metal surface and the strength of subsequent bonds were tested using the Martin Marietta and double-wipe cleaning methods. Results are reported.
Kotwal, Grishma; Harrison, Mark A.; Law, S. Edward; Harrison, Judy A.
2013-01-01
Human noroviruses are major etiologic agents of epidemic gastroenteritis. Outbreaks are often accompanied by contamination of environmental surfaces, but since these viruses cannot be routinely propagated in laboratory cultures, their response to surface disinfectants is predicted by using surrogates, such as murine norovirus 1 (MNV-1). This study compared the virucidal efficacies of various liquid treatments (three sanitizer liquids, 5% levulinic acid plus 2% SDS [LEV/SDS], 200 ppm chlorine, and an isopropanol-based quaternary ammonium compound [Alpet D2], and two control liquids, sterile tap water and sterile tap water plus 2% SDS) when delivered to MNV-1-inoculated stainless steel surfaces by conventional hydraulic or air-assisted, induction-charged (AAIC) electrostatic spraying or by wiping with impregnated towelettes. For the spray treatments, LEV/SDS proved effective when applied with hydraulic and AAIC electrostatic spraying, providing virus reductions of 2.71 and 1.66 log PFU/ml, respectively. Alpet D2 provided a 2.23-log PFU/ml reduction with hydraulic spraying, outperforming chlorine (1.16-log PFU/ml reduction). Chlorine and LEV/SDS were equally effective as wipes, reducing the viral load by 7.05 log PFU/ml. Controls reduced the viral load by <1 log with spraying applications and by >3 log PFU/ml with wiping. Results indicated that both sanitizer type and application methods should be carefully considered when choosing a surface disinfectant to best prevent and control environmental contamination by noroviruses. PMID:23263949
Kusumaningrum, H D; Paltinaite, R; Koomen, A J; Hazeleger, W C; Rombouts, F M; Beumer, R R
2003-12-01
Effective cleaning and sanitizing of food preparation sites is important because pathogens are readily spread to food contact surfaces after preparation of contaminated raw products. Tolerance of Salmonella Enteritidis and Staphylococcus aureus to surface cleaning by wiping with regular, microfiber, and antibacterial-treated cloths was investigated. Wiping with cleaning cloths resulted in a considerable reduction of microorganisms from surfaces, despite the greater difficulty in removing S. aureus than Salmonella Enteritidis. Depending on the cloth type, S. aureus were reduced on surfaces from initial numbers of approximately 10(5) CFU/100 cm2 to numbers from less than 4 CFU/100 cm2 (below the detection limit) to 100 CFU/100 cm2. Directly after the cloths were used to clean the contaminated surfaces, they contained high numbers of bacteria (10(4) to 10(5) CFU/100 cm2), except for the disposable antibacterial-treated cloths, in which no bacteria could be detected. The tolerance of these pathogens to sodium hypochlorite was studied in the suspension test and in cloths. S. aureus showed a better tolerance for sodium hypochlorite than Salmonella Enteritidis. Inactivation of microorganisms in cloths required a higher concentration of sodium hypochlorite than was needed in the suspension test. Repeated exposure to sodium hypochlorite, however, resulted in an increase in susceptibility to this compound. This study provides essential information about the transfer of bacteria when wiping surfaces and highlights the need for a hygiene procedure with cleaning cloths that sufficiently avoids cross-contamination in the household environment.
Removal of biofilm from contact lens storage cases.
Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona
2010-12-01
Lens case hygiene practices are important in maintaining safe contact lens wear. However, the effectiveness of various lens case cleaning practices have not been evaluated and compared. This in vitro study aimed to evaluate and compare the efficacy of cleaning practices that are most commonly carried out by lens wearers and recommended by practitioners. Pseudomonas aeruginosa 122, Serratia marcescens ATCC 13880, and Staphylococcus aureus ATCC 6538 were the challenge bacteria for biofilm formation on unused lens cases from two different manufacturers. After establishment of the biofilm, each lens case was subjected to one of the six cleaning regimens: "rinsed," "rubbed and rinsed," "air-dried," "soaked in a multipurpose contact lens solution," "tissue-wiped," and "lids recapped." The level of residual biofilm was quantified at the end of each cleaning regimen. The efficacy of each cleaning regimen was then compared. Mechanical rubbing and wiping of lens cases were the most effective cleaning regimen tested in reducing biofilm. Soaking lenses in disinfecting solution for 6 hours removed the majority of biofilm from lens cases. Rinsing lens cases alone provided only minimal efficacy in reducing biofilm. Air-drying or recapping the cases with the lid without any other additional cleaning methods were the least efficient at removing biofilm. Based on this study, digital rubbing and rinsing and/or wiping the lens cases with tissue is recommended. Air-drying or recapping the lens case lids after use without any additional cleaning methods should be discouraged with non-antimicrobial lens cases.
Holtyn, August F; Jarvis, Brantley P; Subramaniam, Shrinidhi; Wong, Conrad J; Fingerhood, Michael; Bigelow, George E; Silverman, Kenneth
2017-09-01
Excessive alcohol use among the homeless may contribute to their high rates of emergency department use. Survey-based studies have provided some information on the relation between alcohol and emergency department use among the homeless. This study used an intensive schedule of random breath collections and self-report assessments to examine the relation between emergency department utilization and alcohol use in homeless alcohol-dependent adults. Data were from homeless alcohol-dependent adults (N=116) who were participating in a therapeutic workplace that provided job-skills training every weekday for 26 weeks. Breath-sample collections and assessments of self-reported alcohol use were scheduled each week, an average of twice per week per participant, at random times between 9:00 A.M. and 5:00 P.M. Participants received $35 for each breath sample collected. Self-reports of emergency department use were assessed throughout the study. Thirty-four percent of participants reported attending an emergency department and reported an average of 2.2 emergency department visits (range 1-10 visits). Alcohol intoxication was the most common reason for emergency department use. Participants who used the emergency department had significantly more alcohol-positive breath samples and more self-reported heavy alcohol use than participants who did not use the emergency department. This study provided a rare intensive assessment of alcohol and emergency department use in homeless alcohol-dependent adults over an extended period. Emergency department use was high and was significantly related to indices of alcohol use. Copyright © 2017 Elsevier B.V. All rights reserved.
Giga, Noreen M.; Binakonsky, Jane; Ross, Craig; Siegel, Michael
2011-01-01
Background Flavored alcoholic beverages are popular among underage drinkers. Existing studies that assessed flavored alcoholic beverage use among youth relied upon respondents to correctly classify the beverages they consume, without defining what alcohol brands belong to this category. Objectives To demonstrate a new method for analyzing the consumption of flavored alcoholic beverages among youth on a brand-specific basis, without relying upon youth to correctly classify brands they consume. Methods Using a pre-recruited internet panel developed by Knowledge Networks, we measured the brands of alcohol consumed by a national sample of youth drinkers, ages 16-20 years, in the United States. The sample consisted of 108 youths who had consumed at least one drink of an alcoholic beverage in the past 30 days. We measured the brand-specific consumption of alcoholic beverages within the past 30 days, ascertaining the consumption of 380 alcohol brands, including 14 brands of flavored alcoholic beverages. Results Measuring the brand-specific consumption of flavored alcoholic beverages was feasible. Based on a brand-specific identification of flavored alcoholic beverages, nearly half of youth drinkers in the sample reported having consumed such beverages in the past 30 days. Flavored alcoholic beverage preference was concentrated among the top four brands, which accounted for nearly all of the consumption volume reported in our study. Conclusions and Scientific Significance These findings underscore the need to assess youth alcohol consumption at the brand level and the potential value of such data in better understanding underage youth drinking behavior and the factors that influence it. PMID:21517708
Giga, Noreen M; Binakonsky, Jane; Ross, Craig; Siegel, Michael
2011-07-01
Flavored alcoholic beverages are popular among underage drinkers. Existing studies that assessed flavored alcoholic beverage use among youth relied upon respondents to correctly classify the beverages they consume, without defining what alcohol brands belong to this category. The aim is to demonstrate a new method for analyzing the consumption of flavored alcoholic beverages among youth on a brand-specific basis, without relying upon youth to correctly classify brands they consume. Using a prerecruited Internet panel developed by Knowledge Networks, we measured the brands of alcohol consumed by a national sample of youth drinkers, aged 16?20 years, in the United States. The sample consisted of 108 youths who had consumed at least one drink of an alcoholic beverage in the past 30 days. We measured the brand-specific consumption of alcoholic beverages within the past 30 days, ascertaining the consumption of 380 alcohol brands, including 14 brands of flavored alcoholic beverages. Measuring the brand-specific consumption of flavored alcoholic beverages was feasible. Based on a brand-specific identification of flavored alcoholic beverages, nearly half of the youth drinkers in the sample reported having consumed such beverages in the past 30 days. Flavored alcoholic beverage preference was concentrated among the top four brands, which accounted for almost all of the consumption volume reported in our study. These findings underscore the need to assess youth alcohol consumption at the brand level and the potential value of such data in better understanding underage youth drinking behavior and the factors that influence it.
Does Nosema ceranae Wipe Out Nosema apis in Turkey?
Ivgin Tunca, Rahşan; Oskay, Devrim; Gosterit, Ayhan; Tekin, Olgay Kaan
2016-01-01
The aim of this study was to determine the prevalence of the Nosema ceranae and Nosema apis among apiaries using both spore counts and multiplex PCR and the replacement of N. apis by N. ceranae in some regions of Turkey. A hundred honey bee samples were collected from 99 apiaries in 11 different locations in 2011-2012 in Turkey. Nosema infection degree from collected samples was determined using light microscope and molecular detection of Nosema spp. ( N. ceranae and N. apis ) was performed using specific primers by multiplex PCR. N. ceranae was only found spores in sampling areas using molecular diagnosis. N. apis was not detected in whole sampling areas using both techniques. There are no Nosema spores detected in Konya one location using two techniques. The nucleotide sequences from amplification products of the Nosema infested honeybee samples were (98%) identical with the sequence of N. ceranae for many countries deposited in the GenBank database in this study. The present study illustrated that N. ceranae is the only spores for sampled areas in 2011-2012. The study could also indicate that N. ceranae has been replaced instead of N . apis in Turkey. In addition, the prevalence of N. ceranae and two microsporodia spores effects on honey bee colonies in Turkey were needed to determine with intensive sampling, periodically.
De Boni, Raquel; do Nascimento Silva, Pedro Luis; Bastos, Francisco Inácio; Pechansky, Flavio; de Vasconcellos, Mauricio Teixeira Leite
2012-01-01
Drinking alcoholic beverages in places such as bars and clubs may be associated with harmful consequences such as violence and impaired driving. However, methods for obtaining probabilistic samples of drivers who drink at these places remain a challenge – since there is no a priori information on this mobile population – and must be continually improved. This paper describes the procedures adopted in the selection of a population-based sample of drivers who drank at alcohol selling outlets in Porto Alegre, Brazil, which we used to estimate the prevalence of intention to drive under the influence of alcohol. The sampling strategy comprises a stratified three-stage cluster sampling: 1) census enumeration areas (CEA) were stratified by alcohol outlets (AO) density and sampled with probability proportional to the number of AOs in each CEA; 2) combinations of outlets and shifts (COS) were stratified by prevalence of alcohol-related traffic crashes and sampled with probability proportional to their squared duration in hours; and, 3) drivers who drank at the selected COS were stratified by their intention to drive and sampled using inverse sampling. Sample weights were calibrated using a post-stratification estimator. 3,118 individuals were approached and 683 drivers interviewed, leading to an estimate that 56.3% (SE = 3,5%) of the drivers intended to drive after drinking in less than one hour after the interview. Prevalence was also estimated by sex and broad age groups. The combined use of stratification and inverse sampling enabled a good trade-off between resource and time allocation, while preserving the ability to generalize the findings. The current strategy can be viewed as a step forward in the efforts to improve surveys and estimation for hard-to-reach, mobile populations. PMID:22514620
Walsh, Jennifer L.; Weinhardt, Lance S.; Kalichman, Seth C.; Carey, Michael P.
2016-01-01
Background Patients in sexually transmitted infection (STI) clinics report high levels of alcohol use, which are associated with risky sexual behavior. However, no studies have examined how changes in alcohol use relate to changes in sexual risk behavior. Purpose We used parallel process latent growth modeling to explore how changes in alcohol use related to changes in sexual behavior across four samples of clinic patients. Methods Patients participating in HIV prevention trials from urban clinics in the Northeastern and Midwestern U.S. (N = 3,761, 59% male, 72% Black) completed measures at 3mo intervals over 9-12mo. Integrative data analysis was used to create composite measures of alcohol use across samples. Sexual risk measures were counts of partners and unprotected sex acts. Parallel process models tested whether alcohol use changes were correlated with changes in number of partners and unprotected sex. Results Growth models with good fit showed decreases that slowed over time in sexual risk behaviors and alcohol use. Parallel process models showed positive correlations between levels of (rs =.17-.40, ps < .001) and changes in (rs = .21-.80, ps < .05) alcohol use and number of sexual partners across studies. There were strong associations between levels of (rs = .25-.43, ps < .001) and changes in (rs = .24-.57, ps < .01) alcohol use and unprotected sex in one study recruiting hazardous drinkers. Conclusions Across four samples of clinic patients, reductions in alcohol use were associated with reductions in the number of sexual partners. HIV prevention interventions may be strengthened by addressing alcohol use. PMID:27550626
Emotion Dysregulation Facets as Mediators of the Relationship between PTSD and Alcohol Misuse
Tripp, Jessica C.; McDevitt-Murphy, Meghan E.
2015-01-01
Introduction Posttraumatic stress disorder (PTSD) and alcohol misuse, which frequently co-occur among combat veterans, have been linked to emotion dysregulation. Emotion dysregulation may explain the link between PTSD and alcohol misuse, and this investigation tested emotion dysregulation as a mediator of that relationship. Method Correlations between PTSD symptoms and cluster symptoms, emotion dysregulation full and subscales, and alcohol misuse were examined in a sample of 139 combat Operation Enduring Freedom/Operation Iraqi Freedom/Operation New Dawn veterans (45% African American; 89% men). Emotion dysregulation full scale and subscales were examined as mediators of the relationship between PTSD symptoms and alcohol misuse for the full sample and men only. Results PTSD symptoms and symptom clusters, emotion dysregulation, and alcohol misuse showed positive correlations for the full sample and men only. Neither the full scale of emotion dysregulation nor the facets of emotion dysregulation mediated the relationship between PTSD symptoms and alcohol misuse for the full sample; among men, the Impulse Control Difficulties when Upset and Lack of Emotional Clarity subscales were mediators of that relationship. Conclusions Impulse control difficulties and lack of emotional clarity may play an important role in the link between PTSD and alcohol misuse for male veterans and should be an important target in treatment for individuals with both disorders disorders. Addressing impulse control difficulties and lack of emotional clarity in those with PTSD and alcohol misuse may improve outcomes by helping individuals identify and describe upsetting emotions and develop healthy coping alternatives to alcohol misuse. PMID:25864136
Beatty, Jessica R.; Rosano, Thomas G.; Strickler, Ronald C.; Graham, Amy E.; Sokol, Robert J.
2016-01-01
Background Ethyl Glucoronide (EtG) and Ethyl Sulfate (EtS) have shown promise as biomarkers for alcohol and may be sensitive enough for use with pregnant women in whom even low-level alcohol use is important. However, there have been reports of over-sensitivity of EtG and EtS to incidental exposure to sources such as alcohol-based hand sanitizer. Further, few studies have evaluated these biomarkers among pregnant women, in whom the dynamics of these metabolites may differ. Objectives This study evaluated whether commercial EtG-EtS testing was vulnerable to high levels of environmental exposure to alcohol in pregnant women. Methods Two separate samples of five nurses—one pregnant and the other postpartum, all of whom reported high levels of alcohol-based hand sanitizer use—provided urine samples before and 4–8 hours after rinsing with alcohol-based mouthwash and using hand sanitizer. The five pregnant nurses provided urine samples before, during, and after an 8-hour nursing shift, during which they repeatedly cleansed with alcohol-based hand sanitizer (mean 33.8 uses). The five postpartum nurses used hand sanitizer repeatedly between baseline and follow-up urine samples. Results No urine samples were positive for EtG-EtS at baseline or follow-up, despite use of mouthwash and—in the pregnant sample—heavy use of hand sanitizer (mean of 33.8 uses) throughout the 8-hour shift. Conclusions/Importance Current, commercially available EtG-EtS testing does not appear vulnerable to even heavy exposure to incidental sources of alcohol among pregnant and postpartum women. PMID:26771303
Measuring public opinion on alcohol policy: a factor analytic study of a US probability sample.
Latimer, William W; Harwood, Eileen M; Newcomb, Michael D; Wagenaar, Alexander C
2003-03-01
Public opinion has been one factor affecting change in policies designed to reduce underage alcohol use. Extant research, however, has been criticized for using single survey items of unknown reliability to define adult attitudes on alcohol policy issues. The present investigation addresses a critical gap in the literature by deriving scales on public attitudes, knowledge, and concerns pertinent to alcohol policies designed to reduce underage drinking using a US probability sample survey of 7021 adults. Five attitudinal scales were derived from exploratory and confirmatory factor analyses addressing policies to: (1) regulate alcohol marketing, (2) regulate alcohol consumption in public places, (3) regulate alcohol distribution, (4) increase alcohol taxes, and (5) regulate youth access. The scales exhibited acceptable psychometric properties and were largely consistent with a rational framework which guided the survey construction.
Wills, Thomas A.; Sargent, James D.; Gibbons, Frederick X.; Gerrard, Meg; Stoolmiller, Mike
2009-01-01
The authors tested a theoretical model of how exposure to alcohol cues in movies predicts level of alcohol use (ever use plus ever and recent binge drinking) and alcohol-related problems. A national sample of younger adolescents was interviewed by telephone with 4 repeated assessments spaced at 8-month intervals. A structural equation modeling analysis performed for ever-drinkers at Time 3 (N = 961) indicated that, controlling for a number of covariates, movie alcohol exposure at Time 1 was related to increases in peer alcohol use and adolescent alcohol use at Time 2. Movie exposure had indirect effects to alcohol use and problems at Times 3 and 4 through these pathways, with direct effects to problems from Time 1 rebelliousness and Time 2 movie exposure also found. Prospective risk-promoting effects were also found for alcohol expectancies, peer alcohol use, and availability of alcohol in the home; protective effects were found for mother’s responsiveness and for adolescent’s school performance and self-control. Theoretical and practical implications are discussed. PMID:19290687
Wills, Thomas A; Sargent, James D; Gibbons, Frederick X; Gerrard, Meg; Stoolmiller, Mike
2009-03-01
The authors tested a theoretical model of how exposure to alcohol cues in movies predicts level of alcohol use (ever use plus ever and recent binge drinking) and alcohol-related problems. A national sample of younger adolescents was interviewed by telephone with 4 repeated assessments spaced at 8-month intervals. A structural equation modeling analysis performed for ever-drinkers at Time 3 (N = 961) indicated that, controlling for a number of covariates, movie alcohol exposure at Time 1 was related to increases in peer alcohol use and adolescent alcohol use at Time 2. Movie exposure had indirect effects to alcohol use and problems at Times 3 and 4 through these pathways, with direct effects to problems from Time 1 rebelliousness and Time 2 movie exposure also found. Prospective risk-promoting effects were also found for alcohol expectancies, peer alcohol use, and availability of alcohol in the home; protective effects were found for mother's responsiveness and for adolescent's school performance and self-control. Theoretical and practical implications are discussed. (PsycINFO Database Record (c) 2009 APA, all rights reserved).
Evolution: How Some Birds Survived When All Other Dinosaurs Died.
Brusatte, Stephen L
2016-05-23
The end-Cretaceous mass extinction wiped out the dinosaurs, including many birds. But some bird lineages survived. May seed-eating have been the key? Copyright © 2016 Elsevier Ltd. All rights reserved.
Adult Catheter Care and Infection Prevention Guide
... or diluted bleach; and wipe with a clean paper towel. Work at a comfortable pace -- the risk ... soap (including under fingernails). • Dry with a clean paper towel. Turn water off with the back of ...
Ethanol concentration in breastmilk after the consumption of non-alcoholic beer.
Schneider, Claudia; Thierauf, Annette; Kempf, Jürgen; Auwärter, Volker
2013-06-01
During lactation, the consumption of ethanol is discussed controversially. After women drink alcoholic beverages, ethanol can be found in breastmilk with a time lag. To abstain from ethanol, but not from the taste of alcoholic beverages, in particular, non-alcoholic beer has become popular in recent years. According to regulations in the United States and most European countries, these "alcohol-free" beverages may still contain ethanol up to 1.2% by volume. To determine how much of this ethanol may reach the breastfed child, a drinking experiment with non-alcoholic beer was performed. Fifteen healthy breastfeeding women participated in the study. After at least 5 days of abstinence from ethanol and the donation of a void breastmilk sample, they were asked to drink 1.5 L of non-alcoholic beer within 1 hour. Breastmilk samples were collected using electronic breast pumps immediately after the end of drinking as well as 1 and 3 hours later. The milk was analyzed for ethanol by headspace-gas chromatography-flame ionization detection using a fully validated method. In two women, trace amounts of ethanol (up to 0.0021 g/L) were found in the samples gained immediately after the drinking period. In the other samples ethanol could not be detected (limit of detection=0.0006 g/L). The mother's consumption of non-alcoholic beer is likely innocuous for the breastfed infant.
O'Brien, Jessica W; Hill, Shirley Y
2014-12-01
Prenatal exposures to alcohol, cigarettes, and other drugs of abuse are associated with numerous adverse consequences for affected offspring, including increased risk for substance use and abuse. However, maternal substance use during pregnancy appears to occur more often in those with a family history of alcohol dependence. Utilizing a sample that is enriched for familial alcohol dependence and includes controls selected for virtual absence of familial alcohol dependence could provide important information on the relative contribution of familial risk and prenatal exposures to offspring substance use. A sample of multigenerational families specifically ascertained to be at either high or low risk for developing alcohol dependence (AD) provided biological offspring for a longitudinal prospective study. High-risk families were selected based on the presence of 2 alcohol-dependent sisters. Low-risk families were selected on the basis of minimal first and second-degree relatives with AD. High-risk (HR = 99) and Low-risk offspring (LR = 110) were assessed annually during childhood and biennially in young adulthood regarding their alcohol, drug, and cigarette use. At the first childhood visit, mothers were interviewed concerning their prenatal use of substances. High-risk mothers were more likely to use alcohol, cigarettes, and other drugs during pregnancy than low-risk control mothers, and to consume these substances in greater quantities. Across the sample, prenatal exposure to alcohol was associated with increased risk for both offspring cigarette use and substance use disorders (SUD), and prenatal cigarette exposure was associated with increased risk for offspring cigarette use. Controlling for risk status by examining patterns within the HR sample, prenatal cigarette exposure remained a specific predictor of offspring cigarette use, and prenatal alcohol exposure was specifically associated with increased risk for offspring SUD. Women with a family history of SUD are at increased risk for substance use during pregnancy. Both familial loading for alcohol dependence and prenatal exposure to alcohol or cigarettes are important risk factors in the development of offspring substance use. An inadequate assessment of family history may obscure important interactions between familial risk and prenatal exposures on offspring outcomes. Copyright © 2015 by the Research Society on Alcoholism.
Adeyiga, Georgetta; Udofia, Emilia A; Yawson, Alfred E
2014-06-01
A hospital based cross-sectional study was conducted to identify the factors associated with alcohol consumption in Ghanaian women of childbearing age. The sample consisted of 394 women of reproductive age, of which 234 were pregnant. Systematic random sampling was used to select respondents from the clinics of the Department of Obstetrics and Gynecology outpatient at the Korle Bu Teaching Hospital in Accra, Ghana. Data were collected using structured questionnaires and analyzed using SPSS for Windows version 17.0. In the three months preceding the survey, 37.6% imbibed alcoholic drinks, while 24.4% had ever imbibed an alcoholic herbal brew. Non-Islamic religion, not being in marital union, consuming an alcoholic herbal brew and considering alcohol was beneficial to health were strong predictors of alcohol consumption. We conclude that the prevalence of alcohol consumption is high among this cohort of Ghanaian women. Women should be screened for alcohol consumption and informed about the dangers of heavy alcohol consumption during pregnancy.
27 CFR 6.95 - Consumer tasting or sampling at retail establishments.
Code of Federal Regulations, 2012 CFR
2012-04-01
... sampling at retail establishments. 6.95 Section 6.95 Alcohol, Tobacco Products and Firearms ALCOHOL AND... tasting or sampling at retail establishments. An industry member may conduct tasting or sampling activities at a retail establishment. The industry member may purchase the products to be used from the...
27 CFR 6.95 - Consumer tasting or sampling at retail establishments.
Code of Federal Regulations, 2014 CFR
2014-04-01
... sampling at retail establishments. 6.95 Section 6.95 Alcohol, Tobacco Products and Firearms ALCOHOL AND... tasting or sampling at retail establishments. An industry member may conduct tasting or sampling activities at a retail establishment. The industry member may purchase the products to be used from the...
27 CFR 6.95 - Consumer tasting or sampling at retail establishments.
Code of Federal Regulations, 2013 CFR
2013-04-01
... sampling at retail establishments. 6.95 Section 6.95 Alcohol, Tobacco Products and Firearms ALCOHOL AND... tasting or sampling at retail establishments. An industry member may conduct tasting or sampling activities at a retail establishment. The industry member may purchase the products to be used from the...
Courtney, Kelly E.; Arellano, Ryan; Barkley-Levenson, Emily; Gálvan, Adriana; Poldrack, Russell A.; MacKillop, James; Jentsch, J. David; Ray, Lara A.
2011-01-01
Background Higher levels of impulsivity have been implicated in the development of alcohol use disorders. Recent findings suggest that impulsivity is not a unitary construct, highlighted by the diverse ways in which the various measures of impulsivity relate to alcohol use outcomes. This study simultaneously tested the following dimensions of impulsivity as determinants of alcohol use and alcohol problems: risky decision-making, self-reported risk attitudes, response inhibition, and impulsive decision-making. Method Participants were a community sample of non-treatment seeking problem drinkers (N = 158). Structural Equation Modeling (SEM) analyses employed behavioral measures of impulsive decision-making (Delay Discounting Task, DDT), response inhibition (Stop Signal Task, SST), and risky decision-making (Balloon Analogue Risk Task, BART), and a self-report measure of risk attitudes (Domain-specific Risk-attitude Scale, DOSPERT), as predictors of alcohol use and of alcohol-related problems in this sample. Results The model fit well, accounting for 38% of the variance in alcohol problems, and identified two impulsivity dimensions that significantly loaded onto alcohol outcomes: (1) impulsive decision-making, indexed by the DDT; and (2) risky decision-making, measured by the BART. Conclusions The impulsive decision-making dimension of impulsivity, indexed by the DDT, was the strongest predictor of alcohol use and alcohol pathology in this sample of problem drinkers. Unexpectedly, a negative relationship was found between risky decision-making and alcohol problems. The results highlight the importance of considering the distinct facets of impulsivity in order to elucidate their individual and combined effects on alcohol use initiation, escalation, and dependence. PMID:22091877
Delayed matching to sample and concurrent learning in nonamnesic humans with alcohol dependence.
Bowden, S C; Benedikt, R; Ritter, A J
1992-05-01
Small samples of alcohol-dependent subjects who showed no clinical signs of Wernicke-Korsakoff syndrome were compared with nonalcohol-dependent controls on two animal memory tests which are performed poorly by human amnesics. Compared to the control subjects, the alcohol-dependent subjects' performance was impaired on a version of the delayed matching to sample task. On concurrent discrimination learning the overall group difference just failed to reach significance. The results are interpreted as suggesting that behavioural impairment may occur in alcohol-dependent subjects who are not clinically amnesic, and that the impairment is similar in type to that observed in cases of severe Wernicke-Korsakoff syndrome.