Sample records for alert column operators

  1. Instrument for the measurement and determination of chemical pulse column parameters

    DOEpatents

    Marchant, Norman J.; Morgan, John P.

    1990-01-01

    An instrument for monitoring and measuring pneumatic driving force pulse parameters applied to chemical separation pulse columns obtains real time pulse frequency and root mean square amplitude values, calculates column inch values and compares these values against preset limits to alert column operators to the variations of pulse column operational parameters beyond desired limits.

  2. The Deformity Angular Ratio: Does It Correlate With High-Risk Cases for Potential Spinal Cord Monitoring Alerts in Pediatric 3-Column Thoracic Spinal Deformity Corrective Surgery?

    PubMed

    Lewis, Noah D H; Keshen, Sam G N; Lenke, Lawrence G; Zywiel, Michael G; Skaggs, David L; Dear, Taylor E; Strantzas, Samuel; Lewis, Stephen J

    2015-08-01

    A retrospective analysis. The purpose of this study was to determine whether the deformity angular ratio (DAR) can reliably assess the neurological risks of patients undergoing deformity correction. Identifying high-risk patients and procedures can help ensure that appropriate measures are taken to minimize neurological complications during spinal deformity corrections. Subjectively, surgeons look at radiographs and evaluate the riskiness of the procedure. However, 2 curves of similar magnitude and location can have significantly different risks of neurological deficit during surgery. Whether the curve spans many levels or just a few can significantly influence surgical strategies. Lenke et al have proposed the DAR, which is a measure of curve magnitude per level of deformity. The data from 35 pediatric spinal deformity correction procedures with thoracic 3-column osteotomies were reviewed. Measurements from preoperative radiographs were used to calculate the DAR. Binary logistic regression was used to model the relationship between DARs (independent variables) and presence or absence of an intraoperative alert (dependent variable). In patients undergoing 3-column osteotomies, sagittal curve magnitude and total curve magnitude were associated with increased incidence of transcranial motor evoked potential changes. Total DAR greater than 45° per level and sagittal DAR greater than 22° per level were associated with a 75% incidence of a motor evoked potential alert, with the incidence increasing to 90% with sagittal DAR of 28° per level. In patients undergoing 3-column osteotomies for severe spinal deformities, the DAR was predictive of patients developing intraoperative motor evoked potential alerts. Identifying accurate radiographical, patient, and procedural risk factors in the correction of severe deformities can help prepare the surgical team to improve safety and outcomes when carrying out complex spinal corrections. 3.

  3. Alertness management in two-person long-haul flight operations

    NASA Technical Reports Server (NTRS)

    Rosekind, M. R.; Gander, P. H.

    1992-01-01

    Long-haul flight operations involve cumulative sleep loss, circadian disruption, and extended and irregular duty schedules. These factors reduce pilot alertness and performance on the flightdeck. Conceptually and operationally, alertness management in flight operations can be divided into preventive strategies and operational countermeasures. Preventive strategies are utilized prior to a duty period to mitigate or reduce the effects of sleep loss, circadian disruption and fatigue during subsequent flight operations. Operational countermeasures are used during operations as acute techniques for maintaining performance and alertness. Results from previous NASA Ames field studies document the sleep loss and circadian disruption in three-person long-haul flying and illustrate the application of preventive strategies and operational countermeasures. One strategy that can be used in both a preventive and operational manner is strategic napping. The application and effectiveness of strategic napping in long-haul operations will be discussed. Finally, long-haul flying in two-person highly automated aircraft capable of extended range operations will create new challenges to maintaining pilot alertness and performance. Alertness management issues in this flight environment will be explored.

  4. 75 FR 20671 - Seventieth Meeting: RTCA Special Committee 147: Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-20

    ... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...

  5. Radar-based alert system to operate a sewerage network: relevance and operational effectiveness after several years of use.

    PubMed

    Faure, D; Payrastre, O; Auchet, P

    2005-01-01

    Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.

  6. 76 FR 11846 - Seventy-second Meeting: RTCA Special Committee 147: Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-03

    ... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147 meeting: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...

  7. 75 FR 52590 - Seventy-First Meeting: RTCA Special Committee 147: Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-26

    ... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...

  8. 76 FR 58077 - Seventy-Third Meeting: RTCA Special Committee 147: Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-19

    ... Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Committee 147 meeting: Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance... RTCA Special Committee 147: Minimum Operational Performance Standards for Traffic Alert and Collision...

  9. Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor

    2016-01-01

    A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method. Further analysis on the alert lead time (time in advance of predicted loss of well clear at which a DAA alert is first issued) indicated a strong positive correlation between alert lead time and DAA system performance (i.e. the ability of the UAS pilot to maneuver the unmanned aircraft to remain well clear). While bigger distance thresholds had beneficial effects on alert lead time and missed alert rate, it also generated a higher rate of false alerts. In the design and development of DAA alerting and guidance systems, therefore, the positive and negative effects of false alerts and missed alerts should be carefully considered to achieve acceptable alerting system performance by balancing false and missed alerts. The results and methodology presented in this study are expected to help stakeholders, policymakers and standards committees define the appropriate setting of DAA system parameter thresholds for UAS that ensure safety while minimizing operational impacts to the NAS and equipage requirements for its users before DAA operational performance standards can be finalized.

  10. Statistics from the Operation of the Low-Level Wind Shear Alert System (LLWAS) during the Joint Airport Weather Studies (JAWS) Project.

    DTIC Science & Technology

    1984-12-01

    AD-RI59 367 STATISTICS FROM THE OPERATION OF THE LOW-LEVEL WIND I/i SHEAR ALERT SYSTEM (L..(U) NATIONAL CENTER FOR ATOMSPHERIC RESEARCH BOULDER CO...NATIONAL BUREAU OF STANDARDS-1963A % % Oh b DOT/FAAIPM-84132 Statistics from the Operation of the Program Engineering Low-Level Wind Shear Alert System and...The Operation of The Low-Level Wind December 1984 Shear Alert System (LLWAS) During The JAWS Project: 6. Performing Organization Code An Interim Report

  11. 49 CFR 229.140 - Alerters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alerters shall provide an audio alarm upon expiration of the timing cycle interval. An alerter on a... indication to the operator at least five seconds prior to an audio alarm. The visual indication on an alerter...

  12. 78 FR 61445 - Seventy-Sixth Meeting: RTCA Special Committee 147, Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-03

    ... Committee 147, Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...

  13. 78 FR 66419 - Seventy Sixth Meeting: RTCA Special Committee 147, Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-05

    ... Committee 147, Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...

  14. 77 FR 29749 - 74th Meeting: RTCA Special Committee 147, Minimal Operations Performance Standards for Traffic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-18

    ... 147, Minimal Operations Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...

  15. 78 FR 6401 - Seventy Fifth Meeting: RTCA Special Committee 147, Minimum Operational Performance Standards for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-30

    ... Committee 147, Minimum Operational Performance Standards for Traffic Alert and Collision Avoidance Systems... Traffic Alert and Collision Avoidance Systems Airborne Equipment. SUMMARY: The FAA is issuing this notice... Performance Standards for Traffic Alert and Collision Avoidance Systems Airborne Equipment. DATES: The meeting...

  16. 78 FR 65206 - Airworthiness Directives; Bell Helicopter Textron Canada Limited (Bell) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... engine speeds during steady- state operations. These actions are intended to alert pilots to avoid... intended to alert pilots to avoid certain engine speeds during steady- state operations, prevent failure of... decal as described in Bell Alert Service Bulletin (ASB) No. 430-05-34, dated June 10, 2005 (ASB 430-05...

  17. 78 FR 65202 - Airworthiness Directives; Bell Helicopter Textron Canada Limited (Bell) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... engine speeds during steady-state operations. These actions are intended to alert pilots to avoid certain... operation between speeds of 71% and 92%. The proposed requirements were intended to alert pilots to avoid... amending the RFM, advising pilots of the change, and installing a decal as described in Bell Alert Service...

  18. Human Factors Evaluation of Conflict Detection Tool for Terminal Area

    NASA Technical Reports Server (NTRS)

    Verma, Savita Arora; Tang, Huabin; Ballinger, Deborah; Chinn, Fay Cherie; Kozon, Thomas E.

    2013-01-01

    A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.

  19. The EDUTECH Report, 2002-2003.

    ERIC Educational Resources Information Center

    Warger, Thomas, Ed.

    2003-01-01

    This document consists of 12 issues, an entire volume year, of "The EDUTECH Report." The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, and a question and answer column. Most issues also contain brief quotations on education…

  20. The EDUTECH Report, 2001-2002.

    ERIC Educational Resources Information Center

    Warger, Thomas, Ed.

    2002-01-01

    This document consists of 12 issues of the "EDUTECH Report." The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, and a question and answer column. Issues also contain brief quotations on education technology topics. The…

  1. Alertness management : strategic naps in operational settings

    DOT National Transportation Integrated Search

    1995-01-01

    Managing fatigue in complex operational settings requires attention to multiple factors, including hours of service, scheduling, education and training, countermeasures, technology, and research. Alertness-management strategies can be used to promote...

  2. 47 CFR 11.56 - EAS Participants receive CAP-formatted alerts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Participants receive CAP-formatted alerts... SYSTEM (EAS) Emergency Operations § 11.56 EAS Participants receive CAP-formatted alerts. Notwithstanding anything herein to the contrary, all EAS Participants must be able to receive CAP-formatted EAS alerts no...

  3. Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation

    NASA Technical Reports Server (NTRS)

    Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James

    2015-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.

  4. TALON: the telescope alert operation network system: intelligent linking of distributed autonomous robotic telescopes

    NASA Astrophysics Data System (ADS)

    White, Robert R.; Wren, James; Davis, Heath R.; Galassi, Mark; Starr, Daniel; Vestrand, W. T.; Wozniak, P.

    2004-09-01

    The internet has brought about great change in the astronomical community, but this interconnectivity is just starting to be exploited for use in instrumentation. Utilizing the internet for communicating between distributed astronomical systems is still in its infancy, but it already shows great potential. Here we present an example of a distributed network of telescopes that performs more efficiently in synchronous operation than as individual instruments. RAPid Telescopes for Optical Response (RAPTOR) is a system of telescopes at LANL that has intelligent intercommunication, combined with wide-field optics, temporal monitoring software, and deep-field follow-up capability all working in closed-loop real-time operation. The Telescope ALert Operations Network (TALON) is a network server that allows intercommunication of alert triggers from external and internal resources and controls the distribution of these to each of the telescopes on the network. TALON is designed to grow, allowing any number of telescopes to be linked together and communicate. Coupled with an intelligent alert client at each telescope, it can analyze and respond to each distributed TALON alert based on the telescopes needs and schedule.

  5. Cockpit display of hazardous weather information

    NASA Technical Reports Server (NTRS)

    Hansman, R. John, Jr.; Wanke, Craig

    1991-01-01

    Information transfer and display issues associated with the dissemination of hazardous weather warnings are studied in the context of wind shear alerts. Operational and developmental wind shear detection systems are briefly reviewed. The July 11, 1988 microburst events observed as part of the Denver Terminal Doppler Weather Radar (TDWR) operational evaluation are analyzed in terms of information transfer and the effectiveness of the microburst alerts. Information transfer, message content and display issues associated with microburst alerts generated from ground based sources (Doppler Radar, Low Level Wind Shear Alert System, and Pilot Reports) are evaluated by means fo pilot opinion surveys and part task simulator studies.

  6. The EDUTECH Report, 1997-1998.

    ERIC Educational Resources Information Center

    EDUTECH Report, 1998

    1998-01-01

    This document consists of 12 issues of the EDUTECH Report. 1998. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief quotations on…

  7. The EDUTECH Report, 2000-2001.

    ERIC Educational Resources Information Center

    Warger, Thomas, Ed.

    2001-01-01

    This document consists of 12 issues, an entire volume year, of the EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief…

  8. The EDUTECH Report, 1998-1999.

    ERIC Educational Resources Information Center

    EDUTECH Report, 1999

    1999-01-01

    This document consists of 12 issues, an entire volume year, of the EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief…

  9. The EDUTECH Report, 1999-2000.

    ERIC Educational Resources Information Center

    EDUTECH Report, 2000

    2000-01-01

    This document consists of the 12 issues, an entire volume year, of the 1999-2000 EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two or three articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also…

  10. Assessing contextual factors that influence acceptance of pedestrian alerts by a night vision system.

    PubMed

    Källhammer, Jan-Erik; Smith, Kip

    2012-08-01

    We investigated five contextual variables that we hypothesized would influence driver acceptance of alerts to pedestrians issued by a night vision active safety system to inform the specification of the system's alerting strategies. Driver acceptance of automotive active safety systems is a key factor to promote their use and implies a need to assess factors influencing driver acceptance. In a field operational test, 10 drivers drove instrumented vehicles equipped with a preproduction night vision system with pedestrian detection software. In a follow-up experiment, the 10 drivers and 25 additional volunteers without experience with the system watched 57 clips with pedestrian encounters gathered during the field operational test. They rated the acceptance of an alert to each pedestrian encounter. Levels of rating concordance were significant between drivers who experienced the encounters and participants who did not. Two contextual variables, pedestrian location and motion, were found to influence ratings. Alerts were more accepted when pedestrians were close to or moving toward the vehicle's path. The study demonstrates the utility of using subjective driver acceptance ratings to inform the design of active safety systems and to leverage expensive field operational test data within the confines of the laboratory. The design of alerting strategies for active safety systems needs to heed the driver's contextual sensitivity to issued alerts.

  11. Auditory decision aiding in supervisory control of multiple unmanned aerial vehicles.

    PubMed

    Donmez, Birsen; Cummings, M L; Graham, Hudson D

    2009-10-01

    This article is an investigation of the effectiveness of sonifications, which are continuous auditory alerts mapped to the state of a monitored task, in supporting unmanned aerial vehicle (UAV) supervisory control. UAV supervisory control requires monitoring a UAV across multiple tasks (e.g., course maintenance) via a predominantly visual display, which currently is supported with discrete auditory alerts. Sonification has been shown to enhance monitoring performance in domains such as anesthesiology by allowing an operator to immediately determine an entity's (e.g., patient) current and projected states, and is a promising alternative to discrete alerts in UAV control. However, minimal research compares sonification to discrete alerts, and no research assesses the effectiveness of sonification for monitoring multiple entities (e.g., multiple UAVs). The authors conducted an experiment with 39 military personnel, using a simulated setup. Participants controlled single and multiple UAVs and received sonifications or discrete alerts based on UAV course deviations and late target arrivals. Regardless of the number of UAVs supervised, the course deviation sonification resulted in reactions to course deviations that were 1.9 s faster, a 19% enhancement, compared with discrete alerts. However, course deviation sonifications interfered with the effectiveness of discrete late arrival alerts in general and with operator responses to late arrivals when supervising multiple vehicles. Sonifications can outperform discrete alerts when designed to aid operators to predict future states of monitored tasks. However, sonifications may mask other auditory alerts and interfere with other monitoring tasks that require divided attention. This research has implications for supervisory control display design.

  12. TALON - The Telescope Alert Operation Network System : intelligent linking of distributed autonomous robotic telescopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, R. R.; Wren, J.; Davis, H. R.

    2004-01-01

    The internet has brought about great change in the astronomical community, but this interconnectivity is just starting to be exploited for use in instrumentation. Utilizing the internet for communicating between distributed astronomical systems is still in its infancy, but it already shows great potential. Here we present an example of a distributed network of telescopes that performs more efficienfiy in synchronous operation than as individual instruments. RAPid Telescopes for Optical Response (RAPTOR) is a system of telescopes at LANL that has intelligent intercommunication, combined with wide-field optics, temporal monitoring software, and deep-field follow-up capability all working in closed-loop real-time operation.more » The Telescope ALert Operations Network (TALON) is a network server that allows intercommunication of alert triggers from external and internal resources and controls the distribution of these to each of the telescopes on the network. TALON is designed to grow, allowing any number of telescopes to be linked together and communicate. Coupled with an intelligent alert client at each telescope, it can analyze and respond to each distributed TALON alert based on the telescopes needs and schedule.« less

  13. 75 FR 63893 - Safety Advisory 2010-03

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ... Advisory; staying alert and situational awareness. SUMMARY: FRA is issuing Safety Advisory 2010-03 to... alert whenever the job that is being performed changes, particularly in main track territory. This.... Additionally, the briefing addressed several existing BNSF operating rules mandating that employees be alert...

  14. XHTML Vocabulary

    Science.gov Websites

    content of resource. contentinfo contains meta information about the content on the page or the page as a Applications Vocabulary alert A message with important, and usually time-sensitive, information. Also see : true, false, or mixed. columnheader A cell containing header information for a column. combobox A

  15. 78 FR 65161 - Airworthiness Directives; Agusta S.p.A. (Type Certificate Currently Held by AgustaWestland S.p.A...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... engine speeds during steady-state operations. These actions are intended to alert pilots to avoid certain... alert pilots to avoid certain engine speeds during steady-state operations, prevent failure of the third...

  16. Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

    NASA Technical Reports Server (NTRS)

    Panangadan, Anand V. (Inventor); Monacos, Steve P. (Inventor)

    2015-01-01

    A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

  17. Flight controller alertness and performance during spaceflight shiftwork operations.

    PubMed

    Kelly, S M; Rosekind, M R; Dinges, D F; Miller, D L; Gillen, K A; Gregory, K B; Aguilar, R D; Smith, R M

    1998-09-01

    Decreased alertness and performance associated with fatigue, sleep loss, and circadian disruption are issues faced by a diverse range of shiftwork operations personnel. During Space Transportation System (STS) operations, Mission Operations Directorate (MOD) personnel provide 24-hr. coverage of critical tasks. A joint NASA Johnson Space Center and NASA Ames Research Center project was undertaken to examine these issues in flight controllers during MOD shiftwork operations. An initial operational test of procedures and measures was conducted during the STS-53 mission in December 1992. The study measures included a Background Questionnaire, a subjective daily logbook completed on a 24-hour basis (to report sleep patterns, work periods, etc.), and an 8 minute performance and mood test battery administered at the beginning, middle, and end of each shift period. Seventeen flight controllers representing the 3 Orbit shifts participated. The initial results clearly support the need for further data collection during other STS missions to document baseline levels of alertness and performance during MOD shiftwork operations. Countermeasure strategies specific to the MOD environment are being developed to minimize the adverse effects of fatigue, sleep loss, and circadian disruption engendered by shiftwork operations. These issues are especially pertinent for the night shift operations and the acute phase advance required for the transition of day shift personnel into the night for shuttle launch. Implementation and evaluation of the countermeasure strategies to maximize alertness and performance is planned. As STS missions extend to further EDO (extended duration orbiters), and timelines and planning for 24-hour Space Station operations continue, alertness and performance issues related to sleep and circadian disruption will remain highly relevant in the MOD environment.

  18. Fatigue and alertness in the United States railroad industry part I: the nature of the problem

    DOT National Transportation Integrated Search

    2000-03-31

    The railroad industry must actively manage employee fatigue and alertness problems to maintain an optimal level of operational safety and productivity. Given the necessity to operate nights and irregular hours, weekends and holidays under a wide rang...

  19. NAS-Wide Fast-Time Simulation Study for Evaluating Performance of UAS Detect-and-Avoid Alerting and Guidance Systems

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Cone, Andrew Clayton; Thipphavong, David P.; Santiago, Confesor

    2016-01-01

    This presentation contains the analysis results of NAS-wide fast-time simulations with UAS and VFR traffic for a single day for evaluating the performance of Detect-and-Avoid (DAA) alerting and guidance systems. This purpose of this study was to help refine and validate MOPS alerting and guidance requirements. In this study, we generated plots of all performance metrics that are specified by RTCA SC-228 Minimum Operational Performance Standards (MOPS): 1) to evaluate the sensitivity of alerting parameters on the performance metrics of each DAA alert type: Preventive, Corrective, and Warning alerts and 2) to evaluate the effect of sensor uncertainty on DAA alerting and guidance performance.

  20. The effect of automated alerts on preoperative anemia management.

    PubMed

    Dilla, Andrew; Wisniewski, Mary Kay; Waters, Jonathan H; Triulzi, Darrell J; Yazer, Mark H

    2015-04-01

    This study evaluated the role of an automated anemia notification system that alerted providers about anemic pre-operative patients. After scheduling surgery, the alert program continuously searched the patient's laboratory data for hemoglobin value(s) in the medical record. When an anemic patient according to the World Health Oganization's criteria was identified, an email was sent to the patient's surgeon, and/or assistant, and/or patient's primary care physician suggesting that the anemia be managed before surgery. Thirteen surgeons participated in this pilot study. In 11 months, there were 70 pre-surgery anemia alerts generated on 69 patients. The surgeries were 60 orthopedic, 7 thoracic, 2 general surgery, and 1 urological. The alerts were sent 15 ± 10 days before surgery. No pre-operative anemia treatment could be found in 37 of 69 (54%) patients. Some form of anemia management was found in 32 of 69 (46%) patients. Of the 23 patients who received iron, only 3 of 23 (13%) of these patients started iron shortly after the alert was generated. The alert likely resulted in the postponement of one surgery for anemia correction. Although anemia diagnosis and management can be complex, it was hoped that receipt of the alert would lead to the management of all anemic patients. Alerts are only effective if they are received and read by a healthcare provider empowered to treat the patient or to make an appropriate referral. Automated preoperative alerts alone are not likely to alter surgeons' anemia management practices. These alerts need to be part of a comprehensive anemia management strategy.

  1. Maximizing Trust in the Wireless Emergency Alerts (WEA) Service

    DTIC Science & Technology

    2014-02-01

    Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software En - gineering Institute, a...AOs will protect their alert-generating systems from misuse. A compro- mised alert-generating system could overload the IPAWS-OPEN message validation...greater accessibility, such as accessing the WEA service re- motely from the scene of an incident. Although we are currently unaware of any alerting

  2. Crew Factors in Flight Operations XIV: Alertness Management in Regional Flight Operations Education Module

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Co, Elizabeth L.; Neri, David F.; Oyung, Raymond L.; Mallis, Melissa M.

    2002-01-01

    Regional operations encompass a broad range of pilots and equipment. This module is intended to help all those involved in regional aviation, including pilots, schedulers, dispatchers, maintenance technicians, policy makers, and others, to understand the physiological factors underlying fatigue, how flight operations affect fatigue, and what can be done to counteract fatigue and maximize alertness and performance in their operations. The overall purpose of this module is to promote aviation safety, performance, and productivity. It is intended to meet three specific objectives: (1) to explain the current state of knowledge about the physiological mechanisms underlying fatigue; (2) to demonstrate how this knowledge can be applied to improving flight crew sleep, performance, and alertness; and (3) to offer strategies for alertness management. Aviation Safety Reporting System (ASRS) and National Transportation Safety Board (NISH) reports are used throughout this module to demonstrate that fatigue is a safety issue in the regional operations community. The appendices at the end of this module include the ASRS reports used for the examples contained in this publication, brief introductions to sleep disorders and relaxation techniques, summaries of relevant NASA publications, and a list of general readings on sleep, sleep disorders, and circadian rhythms.

  3. Alerting, orienting or executive attention networks: differential patters of pupil dilations

    PubMed Central

    Geva, Ronny; Zivan, Michal; Warsha, Aviv; Olchik, Dov

    2013-01-01

    Attention capacities, alerting responses, orienting to sensory stimulation, and executive monitoring of performance are considered independent yet interrelated systems. These operations play integral roles in regulating the behavior of diverse species along the evolutionary ladder. Each of the primary attention constructs—alerting, orienting, and executive monitoring—involves salient autonomic correlates as evidenced by changes in reactive pupil dilation (PD), heart rate, and skin conductance. Recent technological advances that use remote high-resolution recording may allow the discernment of temporo-spatial attributes of autonomic responses that characterize the alerting, orienting, and executive monitoring networks during free viewing, irrespective of voluntary performance. This may deepen the understanding of the roles of autonomic regulation in these mental operations and may deepen our understanding of behavioral changes in verbal as well as in non-verbal species. The aim of this study was to explore differences between psychosensory PD responses in alerting, orienting, and executive conflict monitoring tasks to generate estimates of concurrent locus coeruleus (LC) noradrenergic input trajectories in healthy human adults using the attention networks test (ANT). The analysis revealed a construct-specific pattern of pupil responses: alerting is characterized by an early component (Pa), its acceleration enables covert orienting, and executive control is evidenced by a prominent late component (Pe). PD characteristics seem to be task-sensitive, allowing exploration of mental operations irrespective of conscious voluntary responses. These data may facilitate development of studies designed to assess mental operations in diverse species using autonomic responses. PMID:24133422

  4. 78 FR 66252 - Airworthiness Directives; Bell Helicopter Textron Canada Limited (Bell) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-05

    ... actions are intended to alert pilots to avoid certain engine speeds during steady- state operations...%. The proposed requirements were intended to alert pilots to avoid certain engine speeds during steady... the RFMs, advising pilots of the change, and installing a decal as described in Bell Alert Service...

  5. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...

  6. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...

  7. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...

  8. Flight controller alertness and performance during MOD shiftwork operations

    NASA Technical Reports Server (NTRS)

    Kelly, Sean M.; Rosekind, Mark R.; Dinges, David F.; Miller, Donna L.; Gillen, Kelly A.; Gregory, Kevin B.; Aguilar, Ronald D.; Smith, Roy M.

    1994-01-01

    Decreased alertness and performance associated with fatigue, sleep loss, and circadian disruption are issues faced by a diverse range of shiftwork operations. During STS operations, MOD personnel provide 24 hr. coverage of critical tasks. A joint JSC and ARC project was undertaken to examine these issues in flight controllers during MOD shiftwork operations. An initial operational test of procedures and measures was conducted during STS-53 in Dec. 1992. The study measures included a background questionnaire, a subjective daily logbook completed on a 24 hr. basis (to report sleep patterns, work periods, etc.), and an 8 minute performance and mood test battery administered at the beginning, middle, and end of each shift period. Seventeen Flight controllers representing the 3 Orbit shifts participated. The initial results clearly support further data collection during other STS missions to document baseline levels of alertness and performance during MOD shiftwork operations. These issues are especially pertinent for the night shift operations and the acute phase advance required for the transition of day shift personnel into the night for shuttle launch. Implementation and evaluation of the countermeasure strategies to maximize alertness and performance is planned. As STS missions extend to further extended duration orbiters, timelines and planning for 24 circadian disruption will remain highly relevant in the MOD environment.

  9. Cockpit display of hazardous weather information

    NASA Technical Reports Server (NTRS)

    Hansman, R. John, Jr.; Wanke, Craig

    1990-01-01

    Information transfer and display issues associated with the dissemination of hazardous weather warnings are studied in the context of windshear alerts. Operational and developmental windshear detection systems are briefly reviewed. The July 11, 1988 microburst events observed as part of the Denver Terminal Doppler Weather Radar (TDWR) operational evaluation are analyzed in terms of information transfer and the effectiveness of the microburst alerts. Information transfer, message content and display issues associated with microburst alerts generated from ground based sources are evaluated by means of pilot opinion surveys and part task simulator studies.

  10. Cockpit display of hazardous weather information

    NASA Technical Reports Server (NTRS)

    Hansman, R. John, Jr.; Wanke, Craig

    1989-01-01

    Information transfer and display issues associated with the dissemination of hazardous-weather warnings are studied in the context of wind-shear alerts. Operational and developmental wind-shear detection systems are briefly reviewed. The July 11, 1988 microburst events observed as part of the Denver TDWR operational evaluation are analyzed in terms of information transfer and the effectiveness of the microburst alerts. Information transfer, message content, and display issues associated with microburst alerts generated from ground-based sources (Doppler radars, LLWAS, and PIREPS) are evaluated by means of pilot opinion surveys and part-task simulator studies.

  11. 78 FR 65200 - Airworthiness Directives; Bell Helicopter Textron Canada Limited (Bell) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... vibrations at certain engine speeds during steady- state operations. These actions are intended to alert... proposed requirements were intended to alert pilots to avoid certain engine speeds during steady-state... the change, and installing a decal as described in Bell Alert Service Bulletin (ASB) No. 407-05-67...

  12. Crew Factors in Flight Operations XV: Alertness Management in General Aviation Education Module

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Co, Elizabeth L.; Neri, David F.; Oyung, Raymond L.; Mallis, Melissa M.; Cannon, Mary M. (Technical Monitor)

    2002-01-01

    Regional operations encompass a broad range of pilots and equipment. This module is intended to help all those involved in regional aviation, including pilots, schedulers, dispatchers, maintenance technicians, policy makers, and others, to understand the physiological factors underlying fatigue, how flight operations affect fatigue, and what can be done to counteract fatigue and maximize alertness and performance in their operations. The overall purpose of this module is to promote aviation safety, performance, and productivity. It is intended to meet three specific objectives: (1) to explain the current state of knowledge about the physiological mechanisms underlying fatigue; (2) to demonstrate how this knowledge can be applied to improving flight crew sleep, performance, and alertness; and (3) to offer strategies for alertness management. Aviation Safety Reporting System (ASRS) and National Transportation Safety Board (NISH) reports are used throughout this module to demonstrate that fatigue is a safety issue in the regional operations community. The appendices at the end of this module include the ASRS reports used for the examples contained in this publication, brief introductions to sleep disorders and relaxation techniques, summaries of relevant NASA publications, and a list of general readings on sleep, sleep disorders, and circadian rhythms.

  13. Transient Alerts in LSST

    NASA Astrophysics Data System (ADS)

    Kantor, J.

    During LSST observing, transient events will be detected and alerts generated at the LSST Archive Center at NCSA in Champaign-Illinois. As a very high rate of alerts is expected, approaching ˜ 10 million per night, we plan for VOEvent-compliant Distributor/Brokers (http://voevent.org) to be the primary end-points of the full LSST alert streams. End users will then use these Distributor/Brokers to classify and filter events on the stream for those fitting their science goals. These Distributor/Brokers are envisioned to be operated as a community service by third parties who will have signed MOUs with LSST. The exact identification of Distributor/Brokers to receive alerts will be determined as LSST approaches full operations and may change over time, but it is in our interest to identify and coordinate with them as early as possible. LSST will also operate a limited Distributor/Broker with a filtering capability at the Archive Center, to allow alerts to be sent directly to a limited number of entities that for some reason need to have a more direct connection to LSST. This might include, for example, observatories with significant follow-up capabilities whose observing may temporarily be more directly tied to LSST observing. It will let astronomers create simple filters that limit what alerts are ultimately forwarded to them. These user defined filters will be possible to specify using an SQL-like declarative language, or short snippets of (likely Python) code. We emphasize that this LSST-provided capability will be limited, and is not intended to satisfy the wide variety of use cases that a full-fledged public Event Distributor/Broker could. End users will not be able to subscribe to full, unfiltered, alert streams coming directly from LSST. In this session, we will discuss anticipated LSST data rates, and capabilities for alert processing and distribution/brokering. We will clarify what the LSST Observatory will provide versus what we anticipate will be a community effort.

  14. Alert Triage v 0.1 beta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doak, Justin E.; Ingram, Joe; Johnson, Josh

    2016-01-06

    In the cyber security operations of a typical organization, data from multiple sources are monitored, and when certain conditions in the data are met, an alert is generated in an alert management system. Analysts inspect these alerts to decide if any deserve promotion to an event requiring further scrutiny. This triage process is manual, time-consuming, and detracts from the in-depth investigation of events. We have created a software system that uses supervised machine learning to automatically prioritize these alerts. In particular we utilize active learning to make efficient use of the pool of unlabeled alerts, thereby improving the performance ofmore » our ranking models over passive learning. We have demonstrated the effectiveness of our system on a large, real-world dataset of cyber security alerts.« less

  15. Analysis of Alerting System Failures in Commercial Aviation Accidents

    NASA Technical Reports Server (NTRS)

    Mumaw, Randall J.

    2017-01-01

    The role of an alerting system is to make the system operator (e.g., pilot) aware of an impending hazard or unsafe state so the hazard can be avoided or managed successfully. A review of 46 commercial aviation accidents (between 1998 and 2014) revealed that, in the vast majority of events, either the hazard was not alerted or relevant hazard alerting occurred but failed to aid the flight crew sufficiently. For this set of events, alerting system failures were placed in one of five phases: Detection, Understanding, Action Selection, Prioritization, and Execution. This study also reviewed the evolution of alerting system schemes in commercial aviation, which revealed naive assumptions about pilot reliability in monitoring flight path parameters; specifically, pilot monitoring was assumed to be more effective than it actually is. Examples are provided of the types of alerting system failures that have occurred, and recommendations are provided for alerting system improvements.

  16. 47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1115 Transmission of a distress alert by a station not itself in distress. (a) A station in the mobile or mobile-satellite service which learns that a mobile unit is in distress must initiate and transmit a distress alert...

  17. 47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1115 Transmission of a distress alert by a station not itself in distress. (a) A station in the mobile or mobile-satellite service which learns that a mobile unit is in distress must initiate and transmit a distress alert...

  18. COMESEP: bridging the gap between the SEP, CME, and terrestrial effects scientific communities

    NASA Astrophysics Data System (ADS)

    Crosby, Norma; Veronig, Astrid; Rodriguez, Luciano; Vrsnak, Bojan; Vennerstrøm, Susanne; Malandraki, Olga; Dalla, Silvia; Srivastava, Nandita

    2016-04-01

    In the past there has been a tendency for the geomagnetic storm and solar energetic particle (SEP) communities to work in parallel rather than to apply a cross-disciplinary work approach specifically in regard to space weather forecasting. To provide more awareness on the existing links between these communities, as well as further bridge this gap, the three-year EU FP7 COMESEP (COronal Mass Ejections and Solar Energetic Particles: forecasting the space weather impact) project emphasized cross-collaboration between the SEP, coronal mass ejection, and terrestrial effects scientific communities. COMESEP went from basic solar-terrestrial physics research to space weather operations by developing, validating and implementing multi-purpose tools into an operational 24/7 alert service. Launched in November 2013, the COMESEP alert system provides space weather stakeholders geomagnetic storm alerts ("Event based" and "Next 24 hours") and SEP (proton) storm alerts (E > 10 MeV and E > 60 MeV) without human intervention based on the COMESEP definition of risk. COMESEP alerts and forecasts are freely available on the COMESEP alert website (http://www.comesep.eu/alert), as well as disseminated by e-mail to registered users. Acknowledgement: This work has received funding from the European Commission FP7 Project COMESEP (263252).

  19. Faster from the Depths to Decision: Collecting, Distributing, and Applying Data from NOAA`s Deep-Sea Tsunameters

    NASA Astrophysics Data System (ADS)

    Bouchard, R. H.; Wang, D.; Branski, F.

    2008-05-01

    The National Oceanic and Atmospheric Administration (NOAA) operates two tsunami warning centers (TWCs): the West Coast/Alaska Tsunami Warning Center (ATWC) and Pacific Tsunami Warning Center (PTWC). ATWC provides tsunami alerts to Canadian coastal regions, Virgin Islands, Puerto Rico, and the coasts of continental US and Alaska. PTWC provides local/regional tsunami alerts/advisories to the state of Hawaii. An operational center of the Tsunami Warning System of the Pacific, it provides tsunami alerts to most countries of the Pacific Rim. PTWC also provides tsunami alerts for the Caribbean and Indian Ocean countries on an interim basis. The TWCs aim to issue first tsunami bulletins within 10-15 minutes of the earthquake for tele-tsunamis and within a few minutes for local tsunamis. The TWCs have a requirement for offshore tsunami detection in real-time with a data latency of 1 minute or less. Offshore detection of tsunamis is the purpose of NOAA`s recently completed 39-station array of deep-sea tsunameters. The tsunameters, employing the second-generation DART (Deep-ocean Assessment and Reporting of Tsunamis) technology, can speed tsunami detection information to the TWCs in less than 3 minutes from depths of 6000 meters in the Pacific and Western Atlantic oceans. The tsunameters consist of a Bottom Pressure Recorder (BPR) and a surface buoy. Communication from the BPR to the buoy is via underwater acoustic transmissions. Satellite communications carry the data from the buoy to NOAA`s National Data Buoy Center (NDBC), which operates the tsunameters. The BPRs make pressure measurements, converts them to an equivalent water-column height, and passes them through a tsunami detection algorithm. If the algorithm detects a sufficient change in the height, the tsunameter goes into a rapid reporting mode or Event Mode. The acoustic modem-satellite telecommunications path takes approximately 50 seconds to reach the NDBC server. In a few seconds, NDBC reformats the data and pushes them as messages to the National Weather Service Telecommunications Gateway also known as World Meteorological Organization (WMO) Regional Telecommunication Hub (RTH) Washington. RTH Washington can route more than 50 routine messages per second with reliability for all dissemination to all of its users of 99.9 percent. It provides a latency for high priority traffic of 10 seconds or less and routinely handles 1.2 TB of information per day. Its switching centers are on the Main Trunk Network of the WMO`s Global Telecommunication System (GTS), which provides international distribution of the tsunameter data. The GTS is required to deliver tsunami data and warnings to any connected center within two minutes anywhere in the world. TWCs receive the tsunameter data from RTH Washington via GTS circuits, or download the data from servers at the RTH, in the event the GTS circuits fails. TWCs display the data in real-time in their operations. When a tsunameter goes into Event Mode, the TWCs receive alerts. After subtracting the tide, tsunameter signals can measure tsunamis as small as a few millimeters. The usefulness of the tsunameter data at TWCs was demonstrated in some of the recent events in the Pacific Ocean (Kuril Tsunamis of November 2006 and January 2007, Peru Tsunamis of August 2007 and September 2007) and the Indian Ocean (Southern Sumatra Tsunami of September 2007).

  20. Tactical Conflict Detection in Terminal Airspace

    NASA Technical Reports Server (NTRS)

    Tang, Huabin; Robinson, John E.; Denery, Dallas G.

    2010-01-01

    Air traffic systems have long relied on automated short-term conflict prediction algorithms to warn controllers of impending conflicts (losses of separation). The complexity of terminal airspace has proven difficult for such systems as it often leads to excessive false alerts. Thus, the legacy system, called Conflict Alert, which provides short-term alerts in both en-route and terminal airspace currently, is often inhibited or degraded in areas where frequent false alerts occur, even though the alerts are provided only when an aircraft is in dangerous proximity of other aircraft. This research investigates how a minimal level of flight intent information may be used to improve short-term conflict detection in terminal airspace such that it can be used by the controller to maintain legal aircraft separation. The flight intent information includes a site-specific nominal arrival route and inferred altitude clearances in addition to the flight plan that includes the RNAV (Area Navigation) departure route. A new tactical conflict detection algorithm is proposed, which uses a single analytic trajectory, determined by the flight intent and the current state information of the aircraft, and includes a complex set of current, dynamic separation standards for terminal airspace to define losses of separation. The new algorithm is compared with an algorithm that imitates a known en-route algorithm and another that imitates Conflict Alert by analysis of false-alert rate and alert lead time with recent real-world data of arrival and departure operations and a large set of operational error cases from Dallas/Fort Worth TRACON (Terminal Radar Approach Control). The new algorithm yielded a false-alert rate of two per hour and an average alert lead time of 38 seconds.

  1. - Domestic Vessels « Coast Guard Maritime Commons

    Science.gov Websites

    other commercial vessel regulations. 2/20/2018: Marine Safety Alert 2-18 Operational risk management , planning is essential to safe towing and salvage operations Marine Safety Alert 2-18 is issued to remind member, National Transportation Safety Board, and Mr. Brian Curtis, with NTSB's Office of Marine Safety

  2. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-shore distress alerts by a radio-communication service other than HF operating either: (i) Through the... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the... (ii) On HF using DSC: or (iii) Through the INMARSAT geostationary satellite service, by an additional...

  3. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-shore distress alerts by a radio-communication service other than HF operating either: (i) Through the... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the... (ii) On HF using DSC: or (iii) Through the INMARSAT geostationary satellite service, by an additional...

  4. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, A.; Moses, H. R.

    2016-01-01

    Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were asked to identify the alert as quickly and as accurately as possible. Reaction time and accuracy were measured. Participants identified speech alerts significantly faster than tone alerts. The HERA study investigated the performance of participants in a flight-like environment. Participants were instructed to complete items on a task list and respond to C&W alerts as they occurred. Reaction time and accuracy were measured to determine if the benefits of speech alarms are still present in an applied setting.

  5. Education and Training Module in Alertness Management

    NASA Technical Reports Server (NTRS)

    Mallis, M. M.; Brandt, S. L.; Oyung, R. L.; Reduta, D. D.; Rosekind, M. R.

    2006-01-01

    The education and training module (ETM) in alertness management has now been integrated as part of the training regimen of the Pilot Proficiency Awards Program ("WINGS") of the Federal Aviation Administration. Originated and now maintained current by the Fatigue Countermeasures Group at NASA Ames Research Center, the ETM in Alertness Management is designed to give pilots the benefit of the best and most recent research on the basics of sleep physiology, the causes of fatigue, and strategies for managing alertness during flight operations. The WINGS program is an incentive program that encourages pilots at all licensing levels to participate in recurrent training, upon completion of which distinctive lapel or tie pins (wings) and certificates of completion are awarded. In addition to flight training, all WINGS applicants must attend at least one FAA-sponsored safety seminar, FAA-sanctioned safety seminar, or industry recurrent training program. The Fatigue Countermeasures Group provides an FAA-approved industry recurrent training program through an on-line General Aviation (GA) WINGS ETM in alertness management to satisfy this requirement. Since 1993, the Fatigue Countermeasures Group has translated fatigue and alertness information to operational environments by conducting two-day ETM workshops oriented primarily toward air-carrier operations subject to Part 121 of the Federal Aviation Regulations pertaining to such operations. On the basis of the information presented in the two-day ETM workshops, an ETM was created for GA pilots and was transferred to a Web-based version. To comply with the requirements of the WINGS Program, the original Web-based version has been modified to include hypertext markup language (HTML) content that makes information easily accessible, in-depth testing of alertness-management knowledge, new interactive features, and increased informational resources for GA pilots. Upon successful completion of this training module, a participant receives a computer- screen display of a certificate of completion. The certificate, which includes the pilot s name and an identifying number, can be printed out and submitted, for ground training credit, with the pilot s WINGS application.

  6. Alertness Management In Flight Operations: A NASA Education and Training Module

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Lebacqz, Victor J.; Gander, Philippa H.; Co, Elizabeth L.; Weldon, Keri J.; Smith, Roy M.; Miller, Donna L.; Gregory, Kevin B.; Statler, Irving C. (Technical Monitor)

    1994-01-01

    Since 1980, the NASA Ames Fatigue Countermeasures Program has been conducting research on sleep, circadian rhythms, and fatigue in a variety of flight operations 1. An original goal of the program was to return the scientific and operational knowledge to the aviation industry. To meet this goal, the NASA Ames Fatigue Countermeasures Program has created an Education and Training Module entitled, "Strategies for Alertness Management in Flight Operations." The Module was designed to meet three objectives: 1) explain the current state of knowledge about the physiological mechanisms underlying fatigue, 2) demonstrate how this knowledge can be applied to improve flight crew sleep, performance, and alertness, and 3) offer countermeasure recommendations. The Module is composed of two components: 1) a 60-minute live presentation provided by a knowledgeable individual and 2) a NASA/FAA Technical Memorandum (TM) that contains the presentation materials and appendices with complementary information. The TM is provided to all individuals attending the live presentation. The Module content is divided into three parts: 1) basic information on sleep, sleepiness, circadian rhythms, fatigue, and how flight operations affect these physiological factors, 2) common misconceptions about sleep, sleepiness, and fatigue, and 3) alertness management strategies. The Module is intended for pilots, management personnel, schedulers, flight attendants, and the many other individuals involved in the aviation system.

  7. Transitioning the Defense Automated Neurobehavioral Assessment (DANA) to Operational Use

    DTIC Science & Technology

    2013-10-01

    science concentrates on CONUS-based studies such as testing DANA in clinical drug, fatigue/alertness, concussion and/or depression protocols. The...operationally deployed into the military. 15. SUBJECT TERMS neurocognitive, assessment, NCAT, concussion , mTBI, mild traumatic brain injury, psychological...concentrate)on)CONUS@based)studies)such)as)testing) DANA)in)clinical)drug,)fatigue/alertness,) concussion )and/or)depression)protocols.))The) second

  8. The Swift Burst Alert Telescope Detected Seyfert 1 Galaxies: X-Ray Broadband Properties and Warm Absorbers

    NASA Technical Reports Server (NTRS)

    Winter, Lisa M.; Veilleux, Sylvain; McKernan, Barry; Kallman, T.

    2012-01-01

    We present results from an analysis of the broadband, 0.3-195 keV, X-ray spectra of 48 Seyfert 1-1.5 sources detected in the very hard X-rays with the Swift Burst Alert Telescope (BAT). This sample is selected in an all-sky survey conducted in the 14-195 keV band. Therefore, our sources are largely unbiased toward both obscuration and host galaxy properties. Our detailed and uniform model fits to Suzaku/BAT and XMM-Newton/BAT spectra include the neutral absorption, direct power-law, reflected emission, soft excess, warm absorption, and narrow Fe I K[alpha] emission properties for the entire sample. We significantly detect O VII and O VIII edges in 52% of our sample. The strength of these detections is strongly correlated with the neutral column density measured in the spectrum. Among the strongest detections, X-ray grating and UV observations, where available, indicate outflowing material. The ionized column densities of sources with O VII and O VIII detections are clustered in a narrow range with Nwarm [approx] 1021 cm-2, while sources without strong detections have column densities of ionized gas an order of magnitude lower. Therefore, we note that sources without strong detections likely have warm ionized outflows present but at low column densities that are not easily probed with current X-ray observations. Sources with strong complex absorption have a strong soft excess, which may or may not be due to difficulties in modeling the complex spectra of these sources. Still, the detection of a flat [Gamma] [approx] 1 and a strong soft excess may allow us to infer the presence of strong absorption in low signal-to-noise active galactic nucleus spectra. Additionally, we include a useful correction from the Swift BAT luminosity to bolometric luminosity, based on a comparison of our spectral fitting results with published spectral energy distribution fits from 33 of our sources.

  9. Estimation of alertness levels with changes in decibel scale wavelength of EEG during dual-task simulation of auditory sonar target detection.

    PubMed

    Arjunan, Sridhar P; Kumar, Dinesh K; Jung, Tzyy-Ping

    2010-01-01

    Changes in alertness levels can have dire consequences for people operating and controlling motorized equipment. Past research studies have shown the relationship of Electroencephalogram (EEG) with alertness of the person. This research reports the fractal analysis of EEG and estimation of the alertness levels of the individual based on the changes in the maximum fractal length (MFL) of EEG. The results indicate that MFL of only 2 channels of EEG can be used to identify the loss of alertness of the individual with mean (inverse) correlation coefficient = 0.82. This study has also reported that using the changes in MFL of EEG, the changes in alertness level of a person was estimated with a mean correlation coefficient = 0.69.

  10. Evaluation of Helmet Mounted Display Alerting Symbology

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe; Rutkowski, Michael (Technical Monitor)

    2000-01-01

    Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.

  11. Optimizing the real-time ground level enhancement alert system based on neutron monitor measurements: Introducing GLE Alert Plus

    NASA Astrophysics Data System (ADS)

    Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.

    2014-11-01

    Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.

  12. An Architecture for Network Centric Operations in Unconventional Crisis: Lessons Learnt from Singapore’s SARS Experience

    DTIC Science & Technology

    2004-12-01

    Tan Tock Seng Hospital (TTSH) to Singapore General...critical information, the Alert Manager of other hospitals will use the event defined in the Event Manager at Tan Tock Seng Hospital to automatically...events defined at Tan Tock Seng hospital can be monitored by the Alert Manager operated at the immigration department to ensure that the

  13. Tone-activated, remote, alert communication system

    NASA Technical Reports Server (NTRS)

    Baker, C. D.; Couvillon, L. A.; Hubbard, W. P.; Kollar, F. J.; Postal, R. B.; Tegnelia, C. R.

    1971-01-01

    Pocket sized transmitter, frequency modulated by crystal derived tones, with integral loop antenna provides police with easy operating alert signal communicator which uses patrol car radio to relay signal. Communication channels are time shared by several patrol units.

  14. Alerts in mobile healthcare applications: requirements and pilot study.

    PubMed

    Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina

    2004-06-01

    Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.

  15. Space Environment Forecasting with Neutron Monitors: Establishing a novel service for the ESA SSA Program

    NASA Astrophysics Data System (ADS)

    Papaioannou, Athanasios; Mavromichalaki, Helen; Souvatzoglou, George; Paschalis, Pavlos; Sarlanis, Christos; Dimitroulakos, John; Gerontidou, Maria

    2013-04-01

    High-energy particles released at the Sun during a solar flare or a very energetic coronal mass ejection, result to a significant intensity increase at neutron monitor measurements known as Ground Level Enhancements (GLEs). Due to their space weather impact (i.e. risks and failures at communication and navigation systems, spacecraft electronics and operations, space power systems, manned space missions, and commercial aircraft operations) it is crucial to establish a real-time operational system that would be in place to issue reliable and timely GLE Alerts. Currently, the Cosmic Ray group of the National and Kapodistrian University of Athens is working towards the establishment of a Neutron Monitor Service that will be made available via the Space Weather Portal operated by the European Space Agency (ESA), under the Space Situational Awareness (SSA) Program. To this end, a web interface providing data from multiple Neutron Monitor stations as well as an upgraded GLE Alert will be provided. Both services are now under testing and validation and they will probably enter to an operational phase next year. The core of this Neutron Monitor Service is the GLE Alert software, and therefore, the main goal of this research effort is to upgrade the existing GLE Alert software, to minimize the probability of a false alarm and to enhance the usability of the corresponding results. The ESA Neutron Monitor Service is building upon the infrastructure made available with the implementation of the High-Resolution Neutron Monitor Database (NMDB). In this work the structure of the Neutron Monitor Service for ESA SSA Program and the impact of the novel GLE Alert Service that will be made available to future users via ESA SSA web portal will be presented and further discussed.

  16. The Spacecraft Emergency Response System (SERS) for Autonomous Mission Operations

    NASA Technical Reports Server (NTRS)

    Breed, Julia; Chu, Kai-Dee; Baker, Paul; Starr, Cynthia; Fox, Jeffrey; Baitinger, Mick

    1998-01-01

    Today, most mission operations are geared toward lowering cost through unmanned operations. 7-day/24-hour operations are reduced to either 5-day/8-hour operations or become totally autonomous, especially for deep-space missions. Proper and effective notification during a spacecraft emergency could mean success or failure for an entire mission. The Spacecraft Emergency Response System (SERS) is a tool designed for autonomous mission operations. The SERS automatically contacts on-call personnel as needed when crises occur, either on-board the spacecraft or within the automated ground systems. Plus, the SERS provides a group-ware solution to facilitate the work of the person(s) contacted. The SERS is independent of the spacecraft's automated ground system. It receives and catalogues reports for various ground system components in near real-time. Then, based on easily configurable parameters, the SERS determines whom, if anyone, should be alerted. Alerts may be issued via Sky-Tel 2-way pager, Telehony, or e-mail. The alerted personnel can then review and respond to the spacecraft anomalies through the Netscape Internet Web Browser, or directly review and respond from the Sky-Tel 2-way pager.

  17. Warning Alert HITL Experiment Results

    NASA Technical Reports Server (NTRS)

    Monk, Kevin J.; Ferm, Lisa; Roberts, Zach

    2018-01-01

    Minimum Operational Performance Standards (MOPS) are being developed to support the integration of Unmanned Aircraft Systems (UAS) in the National Airspace (NAS). Input from subject matter experts and multiple research studies have informed display requirements for Detect-and-Avoid (DAA) systems aimed at supporting timely and appropriate pilot responses to collision hazards. Phase 1 DAA MOPS alerting is designed to inform pilots if an avoidance maneuver is necessary; the two highest alert levels - caution and warning - indicate how soon pilot action is required and whether there is adequate time to coordinate with the air traffic controller (ATC). Additional empirical support is needed to clarify the extent to which warning-level alerting impacts DAA task performance. The present study explores the differential effects of the auditory and visual cues provided by the DAA Warning alert, and performance implications compared to caution-only alerting are discussed.

  18. Chemical Safety Alert: Hazards of Delayed Coker Unit (DCU) Operations

    EPA Pesticide Factsheets

    EPA and OSHA jointly publish this Chemical Safety Alert/Safety and Health Information Bulletin (CSA/SHIB) to increase awareness. DCU is a severe form of thermal cracking requiring high temperatures for long periods, for refining crude oils.

  19. Color-tuned neurons are spatially clustered according to color preference within alert macaque posterior inferior temporal cortex

    PubMed Central

    Conway, Bevil R.; Tsao, Doris Y.

    2009-01-01

    Large islands of extrastriate cortex that are enriched for color-tuned neurons have recently been described in alert macaque using a combination of functional magnetic resonance imaging (fMRI) and single-unit recording. These millimeter-sized islands, dubbed “globs,” are scattered throughout the posterior inferior temporal cortex (PIT), a swath of brain anterior to area V3, including areas V4, PITd, and posterior TEO. We investigated the micro-organization of neurons within the globs. We used fMRI to identify the globs and then used MRI-guided microelectrodes to test the color properties of single glob cells. We used color stimuli that sample the CIELUV perceptual color space at regular intervals to test the color tuning of single units, and make two observations. First, color-tuned neurons of various color preferences were found within single globs. Second, adjacent glob cells tended to have the same color tuning, demonstrating that glob cells are clustered by color preference and suggesting that they are arranged in color columns. Neurons separated by 50 μm, measured parallel to the cortical sheet, had more similar color tuning than neurons separated by 100 μm, suggesting that the scale of the color columns is <100 μm. These results show that color-tuned neurons in PIT are organized by color preference on a finer scale than the scale of single globs. Moreover, the color preferences of neurons recorded sequentially along a given electrode penetration shifted gradually in many penetrations, suggesting that the color columns are arranged according to a chromotopic map reflecting perceptual color space. PMID:19805195

  20. Implementing the European Neutron Monitor Service for the ESA SSA Program

    NASA Astrophysics Data System (ADS)

    Mavromichalaki, H.; Papaioannou, A.; Souvatzoglou, G.; Dimitroulakos, J.; Paschalis, P.; Gerontidou, M.; Sarlanis, Ch.

    2013-09-01

    Ground level enhancements (GLEs) are observed as significant intensity increases at neutron monitor measurements, followed by an intense solar flare and/or a very energetic coronal mass ejection. Due to their space weather impact it is crucial to establish a real-time operational system that would be in place to issue reliable and timely GLE Alerts. Such a Neutron Monitor Service that will be made available via the Space Weather Portal operated by the European Space Agency (ESA), under the Space Situational Awareness (SSA) Program, is currently under development. The ESA Neutron Monitor Service will provide two products: a web interface providing data from multiple Neutron Monitor stations as well as an upgraded GLE Alert. Both services are now under testing and validation and will probably enter to an operational phase next year. The core of this Neutron Monitor Service is the GLE Alert software, and therefore, the main goal of this research effort is to upgrade the existing GLE Alert software and to minimize the probability of false alarms. The ESA Neutron Monitor Service is building upon the infrastructure made available with the implementation of the High-Resolution Neutron Monitor Database (NMDB). In this work the structure of the ESA Neutron Monitor Service, the core of the novel GLE Alert Service and its validation results will be presented and further discussed.

  1. Non-visual biological effects of light on human cognition, alertness, and mood

    NASA Astrophysics Data System (ADS)

    Li, Huaye; Wang, Huihui; Shen, Junfei; Sun, Peng; Xie, Ting; Zhang, Siman; Zheng, Zhenrong

    2017-09-01

    Light exerts non-visual effects on a wide range of biological functions and behavior apart from the visual effect. Light can regulate human circadian rhythms, like the secretion of melatonin and cortisol. Light also has influence on body's physiological parameters, such as blood pressure, heart rate and body temperature. However, human cognitive performance, alertness and mood under different lighting conditions have not been considered thoroughly especially for the complicated visual task like surgical operating procedure. In this paper, an experiment was conducted to investigate the cognition, alertness and mood of healthy participants in a simulated operating room (OR) in the hospital. A LED surgical lamp was used as the light source, which is mixed by three color LEDs (amber, green and blue). The surgical lamp is flexible on both spectrum and intensity. Exposed to different light settings, which are varied from color temperature and luminance, participants were asked to take psychomotor vigilance task (PVT) for alertness measurement, alphabet test for cognitive performance measurement, positive and negative affect schedule (PANAS) for mood measurement. The result showed the participants' cognitive performance, alertness and mood are related to the color temperature and luminance of the LED light. This research will have a guidance for the surgical lighting environment, which can not only enhance doctors' efficiency during the operations, but also create a positive and peaceful surgical lighting environment.

  2. Crew factors in flight operations 9: Effects of planned cockpit rest on crew performance and alertness in long-haul operations

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Graeber, R. Curtis; Dinges, David F.; Connell, Linda J.; Rountree, Michael S.; Spinweber, Cheryl L.; Gillen, Kelly A.

    1994-01-01

    This study examined the effectiveness of a planned cockpit rest period to improve alertness and performance in long-haul flight operations. The Rest Group (12 crew members) was allowed a planned 40 minute rest period during the low workload, cruise portion of the flight, while the No-Rest Group (9 crew members) had a 40 minute planned control period when they maintained usual flight activities. Measures used in the study included continuous ambulatory recordings of brain wave and eye movement activity, a reaction time/vigilance task, a wrist activity monitor, in-flight fatigue and alertness ratings, a daily log for noting sleep periods, meals, exercise, flight and duty periods, and the NASA Background Questionnaire. The Rest Group pilots slept on 93 percent of the opportunities, falling asleep in 5.6 minutes and sleeping for 25.8 minutes. This nap was associated with improved physiological alertness and performance compared to the No-Rest Group. The benefits of the nap were observed through the critical descent and landing phases of flight. The nap did not affect layover sleep or the cumulative sleep debt. The nap procedures were implemented with minimal disruption to usual flight operations and there were no reported or identified concerns regarding safety.

  3. Sleep and alertness in North Sea helicopter operations.

    PubMed

    Simons, Ries; Wilschut, Ellen S; Valk, Pierre J L

    2011-07-01

    Dutch North Sea helicopter operations are characterized by multiple sector flights to offshore platforms under difficult environmental conditions. In the context of a Ministry of Transport program to improve safety levels of helicopter operations, we assessed effects of pre-duty sleep, pre-duty travel time, and workload factors on the alertness and vigilance of pilots. Data of 24 pilots comprising 224 duty days were analyzed. Pilots performed 10-min test sessions after wake up, pre-duty, halfway-duty, end-duty, and at bedtime during normal duty rosters. Test sessions included completion of a vigilance task, vigor and sleepiness ratings, and questions on sleep and operational characteristics. Pilots wore an actometer to objectify sleep data. Vigor scores were high and sleepiness levels were low during the entire flight duty periods (FDPs), while vigilance was impaired only 6.8% in the course of the FDPs. Pre-duty sleep before morning duties was 1.5 h shorter than sleep before duties starting after midday. Longer pre-duty travel time was correlated with shorter pre-duty sleep and lower vigilance levels during duty. During the FDPs, pilots maintained alertness and vigilance levels that may be considered safe in terms of alertness-related flight safety. This favorable outcome may be attributed to reasonable length of FDPs, favorable circadian start and end times of duties, sufficient opportunities for restorative pre-duty sleep, and relatively good weather conditions. Appropriate FDP scheduling is an important measure to optimize alertness of helicopter pilots who have to cope with adverse environmental conditions and limited landing and air traffic control facilities.

  4. Some human factors issues in the development and evaluation of cockpit alerting and warning systems

    NASA Technical Reports Server (NTRS)

    Randle, R. J., Jr.; Larsen, W. E.; Williams, D. H.

    1980-01-01

    A set of general guidelines for evaluating a newly developed cockpit alerting and warning system in terms of human factors issues are provided. Although the discussion centers around a general methodology, it is made specifically to the issues involved in alerting systems. An overall statement of the current operational problem is presented. Human factors problems with reference to existing alerting and warning systems are described. The methodology for proceeding through system development to system test is discussed. The differences between traditional human factors laboratory evaluations and those required for evaluation of complex man-machine systems under development are emphasized. Performance evaluation in the alerting and warning subsystem using a hypothetical sample system is explained.

  5. 21 CFR Appendix E to Subpart A of... - Elements To Be Considered in Developing a Two-Way Alert System

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... what circumstances an alert is required —Standard Operating Procedures (SOP's) —Mechanism of health... mechanisms 3. Enforcement Procedures —Followup mechanisms —Corrective action procedures 4. Quality Assurance...

  6. 21 CFR Appendix E to Subpart A of... - Elements To Be Considered in Developing a Two-Way Alert System

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... what circumstances an alert is required —Standard Operating Procedures (SOP's) —Mechanism of health... mechanisms 3. Enforcement Procedures —Followup mechanisms —Corrective action procedures 4. Quality Assurance...

  7. 21 CFR Appendix E to Subpart A of... - Elements To Be Considered in Developing a Two-Way Alert System

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... what circumstances an alert is required —Standard Operating Procedures (SOP's) —Mechanism of health... mechanisms 3. Enforcement Procedures —Followup mechanisms —Corrective action procedures 4. Quality Assurance...

  8. 21 CFR Appendix E to Subpart A of... - Elements To Be Considered in Developing a Two-Way Alert System

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... what circumstances an alert is required —Standard Operating Procedures (SOP's) —Mechanism of health... mechanisms 3. Enforcement Procedures —Followup mechanisms —Corrective action procedures 4. Quality Assurance...

  9. Simulator Evaluation of Runway Incursion Prevention Technology for General Aviation Operations

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III

    2011-01-01

    A Runway Incursion Prevention System (RIPS) has been designed under previous research to enhance airport surface operations situation awareness and provide cockpit alerts of potential runway conflict, during transport aircraft category operations, in order to prevent runway incidents while also improving operations capability. This study investigated an adaptation of RIPS for low-end general aviation operations using a fixed-based simulator at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC). The purpose of the study was to evaluate modified RIPS aircraft-based incursion detection algorithms and associated alerting and airport surface display concepts for low-end general aviation operations. This paper gives an overview of the system, simulation study, and test results.

  10. Real-time data acquisition and alerts may reduce reaction time and improve perfusionist performance during cardiopulmonary bypass.

    PubMed

    Beck, J R; Fung, K; Lopez, H; Mongero, L B; Argenziano, M

    2015-01-01

    Delayed perfusionist identification and reaction to abnormal clinical situations has been reported to contribute to increased mortality and morbidity. The use of automated data acquisition and compliance safety alerts has been widely accepted in many industries and its use may improve operator performance. A study was conducted to evaluate the reaction time of perfusionists with and without the use of compliance alert. A compliance alert is a computer-generated pop-up banner on a pump-mounted computer screen to notify the user of clinical parameters outside of a predetermined range. A proctor monitored and recorded the time from an alert until the perfusionist recognized the parameter was outside the desired range. Group one included 10 cases utilizing compliance alerts. Group 2 included 10 cases with the primary perfusionist blinded to the compliance alerts. In Group 1, 97 compliance alerts were identified and, in group two, 86 alerts were identified. The average reaction time in the group using compliance alerts was 3.6 seconds. The average reaction time in the group not using the alerts was nearly ten times longer than the group using computer-assisted, real-time data feedback. Some believe that real-time computer data acquisition and feedback improves perfusionist performance and may allow clinicians to identify and rectify potentially dangerous situations. © The Author(s) 2014.

  11. A fresh look at runway incursions: onboard surface movement awareness and alerting system based on SVS

    NASA Astrophysics Data System (ADS)

    Vernaleken, Christoph; Mihalic, Lamir; Güttler, Mathias; Klingauf, Uwe

    2006-05-01

    Increasing traffic density on the aerodrome surface due to the continuous worldwide growth in the number of flight operations does not only cause capacity and efficiency problems, but also increases the risk of serious incidents and accidents on the airport movement area. Of these, Runway Incursions are the by far most safety-critical. In fact, the worst-ever accident in civil aviation, the collision of two Boeing B747s on Tenerife in 1977 with 583 fatalities, was caused by a Runway Incursion. Therefore, various Runway Safety programs have recently been initiated around the globe, often focusing on ground-based measures such as improved surveillance. However, as a lack of flight crew situational awareness is a key causal factor in many Runway Incursion incidents and accidents, there is a strong need for an onboard solution, which should be capable of interacting cooperatively with ground-based ATM systems, such as A-SMGCS where available. This paper defines the concept of preventive and reactive Runway Incursion avoidance and describes a Surface Movement Awareness & Alerting System (SMAAS) designed to alert the flight crew if they are at risk of infringing a runway. Both the SVS flight deck displays and the corresponding alerting algorithms utilize an ED 99A/RTCA DO-272A compliant aerodrome database, as well as airport operational, traffic and clearance data received via ADS-B or other data links, respectively. The displays provide the crew with enhanced positional, operational, clearance and traffic awareness, and they are used to visualize alerts. A future enhancement of the system will provide intelligent alerting for conflicts caused by surrounding traffic.

  12. Effects of a malfunctional column on conventional and FeedCol-simulated moving bed chromatography performance.

    PubMed

    Song, Ji-Yeon; Oh, Donghoon; Lee, Chang-Ha

    2015-07-17

    The effects of a malfunctional column on the performance of a simulated moving bed (SMB) process were studied experimentally and theoretically. The experimental results of conventional four-zone SMB (2-2-2-2 configuration) and FeedCol operation (2-2-2-2 configuration with one feed column) with one malfunctional column were compared with simulation results of the corresponding SMB processes with a normal column configuration. The malfunctional column in SMB processes significantly deteriorated raffinate purity. However, the extract purity was equivalent or slightly improved compared with the corresponding normal SMB operation because the complete separation zone of the malfunctional column moved to a lower flow rate range in zones II and III. With the malfunctional column configuration, FeedCol operation gave better experimental performance (up to 7%) than conventional SMB operation because controlling product purity with FeedCol operation was more flexible through the use of two additional operating variables, injection time and injection length. Thus, compared with conventional SMB separation, extract with equivalent or slightly better purity could be produced from FeedCol operation even with a malfunctional column, while minimizing the decrease in raffinate purity (less than 2%). Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Incidence of potential drug interactions in a transplant centre setting and relevance of electronic alerts for clinical practice support.

    PubMed

    Polidori, Piera; Di Giorgio, Concetta; Provenzani, Alessio

    2012-01-01

    Adverse drug events may occur as a result of drug-drug interactions (DDIs). Information technology (IT) systems can be an important decision-making tool for healthcare workers to identify DDIs. The aim of the study is to analyse drug prescriptions in our main hospital units, in order to measure the incidence and severity of potential DDIs. The utility of clinical decision-support systems (CDSSs) and computerised physician order entry (CPOE) in term of alerts adherence was also assessed. DDIs were assessed using a Micromedex® healthcare series database. The system, adopted by the hospital, generates alerts for prescriptions with negative interactions and thanks to an 'acknowledgement function' it is possible to verify physician adherence to alerts. This function, although used previously, became mandatory from September 2010. Physician adherence to alerts and mean monthly incidence of potential DDIs in analysed units, before and after the mandatory 'acknowledgement function', were calculated. The intensive care unit (ICU) registered the greatest incidence of potential DDIs (49.0%), followed by the abdominal surgery unit and dialysis (43.4 and 42.0%, respectively). The cardiothoracic surgery unit (41.6%), step-down unit (38.3%) and post-anaesthesia care unit (30.0%) were comparable. The operating theatre and endoscopy registered the fewest potential DDIs (28.2 and 22.7%, respectively). Adherence to alerts after the 'acknowledgement function' increased by 25.0% in the ICU, 54.0% in the cardiothoracic surgery unit, 52.5% in the abdominal surgery unit, 58.0% in the stepdown unit, 67.0% in dialysis, 51.0% in endoscopy and 48.0% in the post-anaesthesia care unit. In the operating theatre, adherence to alerts decreased from 34.0 to 30.0%. The incidence of potential DDIs after mandatory use of the 'acknowledgement function' decreased slightly in endoscopy (-2.9%), the abdominal surgery unit (-2.7%), dialysis (-1.9%) and the step-down unit (-1.4%). Improving DDI alerts will improved patient safety by more appropriately alerting clinicians.

  14. Alertness, performance and off-duty sleep on 8-hour and 12-hour night shifts in a simulated continuous operations control room setting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.

    A growing number of nuclear power plants in the United States have adopted routine 12-hr shift schedules. Because of the potential impact that extended work shifts could have on safe and efficient power plant operation, the U.S. Nuclear Regulatory Commission funded research on 8-hr and 12-hr shifts at the Human Alertness Research Center (HARC) in Boston, Massachusetts. This report describes the research undertaken: a study of simulated 8-hr and 12-hr work shifts that compares alertness, speed, and accuracy at responding to simulator alarms, and relative cognitive performance, self-rated mood and vigor, and sleep-wake patterns of 8-hr versus 12-hr shift workers.

  15. Collision Avoidance for Airport Traffic Simulation Evaluation

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III; Shelton, Kevin J.; Bailey, Randall E.; Otero, Sharon D.; Barker, Glover D.

    2010-01-01

    A Collision Avoidance for Airport Traffic (CAAT) concept for the airport Terminal Maneuvering Area (TMA) was evaluated in a simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center. CAAT is being designed to enhance surface situation awareness and provide cockpit alerts of potential conflicts during runway, taxi, and low altitude air-to-air operations. The purpose of the study was to evaluate pilot reaction to conflict events in the TMA near the airport, different alert timings for various scenarios, alerting display concepts, and directive alerting concepts. This paper gives an overview of the conflict detection and resolution (CD&R) concept, simulation study, and test results

  16. 47 CFR 80.1114 - False distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false False distress alerts. 80.1114 Section 80.1114 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and...

  17. 47 CFR 80.1114 - False distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false False distress alerts. 80.1114 Section 80.1114 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and...

  18. Runway Incursion Prevention for General Aviation Operations

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III

    2006-01-01

    A Runway Incursion Prevention System (RIPS) and additional incursion detection algorithm were adapted for general aviation operations and evaluated in a simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) in the fall of 2005. RIPS has been designed to enhance surface situation awareness and provide cockpit alerts of potential runway conflicts in order to prevent runway incidents while also improving operational capability. The purpose of the study was to evaluate the airborne incursion detection algorithms and associated alerting and airport surface display concepts for general aviation operations. This paper gives an overview of the system, simulation study, and test results.

  19. Runway Incursion Prevention System for General Aviation Operations

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel III, Lawrence J.

    2006-01-01

    A Runway Incursion Prevention System (RIPS) and additional incursion detection algorithm were adapted for general aviation operations and evaluated in a simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) in the fall of 2005. RIPS has been designed to enhance surface situation awareness and provide cockpit alerts of potential runway conflicts in order to prevent runway incidents while also improving operational capability. The purpose of the study was to evaluate the airborne incursion detection algorithms and associated alerting and airport surface display concepts for general aviation operations. This paper gives an overview of the system, simulation study, and test results.

  20. Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems

    NASA Technical Reports Server (NTRS)

    Song, Lixia; Kuchar, James K.

    2003-01-01

    Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air traffic alert and avoidance systems: the existing Traffic Alert and Collision Avoidance System (TCAS) vs. the proposed Airborne Conflict Management system (ACM). Conditions on ACM resolution maneuvers are identified to avoid dynamic dissonance between TCAS and ACM. Also included in this report is an Appendix written by Lee Winder about recent and continuing work on alerting systems design. The application of Markov Decision Process (MDP) theory to complex alerting problems is discussed and illustrated with an abstract example system.

  1. Geoethical issues involved in Tsunami Warning System concepts and operations

    NASA Astrophysics Data System (ADS)

    Charalampakis, Marinos; Papadopoulos, Gerassimos A.; Tinti, Stefano

    2016-04-01

    The main goal of a Tsunami Warning System (TWS) is to mitigate the effect of an incoming tsunami by alerting coastal population early enough to allow people to evacuate safely from inundation zones. Though this representation might seem oversimplified, nonetheless, achieving successfully this goal requires a positive synergy of geoscience, communication, emergency management, technology, education, social sciences, politics. Geoethical issues arise always when there is an interaction between geoscience and society, and TWS is a paradigmatic case where interaction is very strong and is made critical because a) the formulation of the tsunami alert has to be made in a time as short as possible and therefore on uncertain data, and b) any evaluation error (underestimation or overestimation) can lead to serious (and sometimes catastrophic) consequences involving wide areas and a large amount of population. From the geoethical point of view three issues are critical: how to (i) combine forecasts and uncertainties reasonably and usefully, (ii) cope and possibly solve the dilemma whether it is better over-alerting or under-alerting population and (iii) deal with responsibility and liability of geoscientists, TWS operators, emergency operators and coastal population. The discussion will be based on the experience of the Hellenic National Tsunami Warning Center (HL-NTWC, Greece), which operates on 24/7 basis as a special unit of the Institute of Geodynamics, National Observatory of Athens, and acts also as Candidate Tsunami Service Provider (CTSP) in the framework of the North-Eastern Atlantic, the Mediterranean and connected seas Tsunami Warning System (NEAMTWS) of the IOC/UNESCO. Since August 2012, when HL-NTWC was officially declared as operational, 14 tsunami warning messages have been disseminated to a large number of subscribers after strong submarine earthquakes occurring in Greece and elsewhere in the eastern Mediterranean. It is recognized that the alerting process and procedure are quite complex and deserve an open and wide debate, that at the moment seems to be absent from media, scientific community and society, very likely until the next tsunami disaster.

  2. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  3. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  4. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  5. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  6. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  7. Physiological measures and mental-state assessment

    NASA Technical Reports Server (NTRS)

    Stern, John A.

    1988-01-01

    General considerations regarding monitoring of operators for alertness are discussed, including who should be monitored and what information should be collected. Measures that have been used to ascertain more general and persistent states of alertness are outlined, including cardiac activity, peripheral vascular activity, skin conductance, electroencephalography, pupillography, oculomotor activity, and body movements.

  8. Performance Evaluation of Evasion Maneuvers for Parallel Approach Collision Avoidance

    NASA Technical Reports Server (NTRS)

    Winder, Lee F.; Kuchar, James K.; Waller, Marvin (Technical Monitor)

    2000-01-01

    Current plans for independent instrument approaches to closely spaced parallel runways call for an automated pilot alerting system to ensure separation of aircraft in the case of a "blunder," or unexpected deviation from the a normal approach path. Resolution advisories by this system would require the pilot of an endangered aircraft to perform a trained evasion maneuver. The potential performance of two evasion maneuvers, referred to as the "turn-climb" and "climb-only," was estimated using an experimental NASA alerting logic (AILS) and a computer simulation of relative trajectory scenarios between two aircraft. One aircraft was equipped with the NASA alerting system, and maneuvered accordingly. Observation of the rates of different types of alerting failure allowed judgement of evasion maneuver performance. System Operating Characteristic (SOC) curves were used to assess the benefit of alerting with each maneuver.

  9. Comparative Analysis of ACAS-Xu and DAIDALUS Detect-and-Avoid Systems

    NASA Technical Reports Server (NTRS)

    Davies, Jason T.; Wu, Minghong G.

    2018-01-01

    The Detect and Avoid (DAA) capability of a recent version (Run 3) of the Airborne Collision Avoidance System-Xu (ACAS-Xu) is measured against that of the Detect and AvoID Alerting Logic for Unmanned Systems (DAIDALUS), a reference algorithm for the Phase 1 Minimum Operational Performance Standards (MOPS) for DAA. This comparative analysis of the two systems' alerting and horizontal guidance outcomes is conducted through the lens of the Detect and Avoid mission using flight data of scripted encounters from a recent flight test. Results indicate comparable timelines and outcomes between ACAS-Xu's Remain Well Clear alert and guidance and DAIDALUS's corrective alert and guidance, although ACAS-Xu's guidance appears to be more conservative. ACAS-Xu's Collision Avoidance alert and guidance occurs later than DAIDALUS's warning alert and guidance, and overlaps with DAIDALUS's timeline of maneuver to remain Well Clear. Interesting discrepancies between ACAS-Xu's directive guidance and DAIDALUS's "Regain Well Clear" guidance occur in some scenarios.

  10. An applicable method for efficiency estimation of operating tray distillation columns and its comparison with the methods utilized in HYSYS and Aspen Plus

    NASA Astrophysics Data System (ADS)

    Sadeghifar, Hamidreza

    2015-10-01

    Developing general methods that rely on column data for the efficiency estimation of operating (existing) distillation columns has been overlooked in the literature. Most of the available methods are based on empirical mass transfer and hydraulic relations correlated to laboratory data. Therefore, these methods may not be sufficiently accurate when applied to industrial columns. In this paper, an applicable and accurate method was developed for the efficiency estimation of distillation columns filled with trays. This method can calculate efficiency as well as mass and heat transfer coefficients without using any empirical mass transfer or hydraulic correlations and without the need to estimate operational or hydraulic parameters of the column. E.g., the method does not need to estimate tray interfacial area, which can be its most important advantage over all the available methods. The method can be used for the efficiency prediction of any trays in distillation columns. For the efficiency calculation, the method employs the column data and uses the true rates of the mass and heat transfers occurring inside the operating column. It is highly emphasized that estimating efficiency of an operating column has to be distinguished from that of a column being designed.

  11. Unmanned Aircraft System (UAS) Delegation of Separation in NextGen Airspace

    NASA Technical Reports Server (NTRS)

    Kenny, Caitlin A.; Shively, Robert J.; Jordan, Kevin

    2014-01-01

    The purpose of this study was to determine the feasibility of unmanned aircraft systems (UAS) performing delegated separation in the national airspace system (NAS). Delegated separation is the transfer of responsibility for maintaining separation between aircraft or vehicles from air navigation service providers to the relevant pilot or flight operator. The effects of delegated separation and traffic display information level were collected through performance, workload, and situation awareness measures. The results of this study show benefits related to the use of conflict detection alerts being shown on the UAS operator's cockpit situation display (CSD), and to the use of full delegation. Overall, changing the level of separation responsibility and adding conflict detection alerts on the CSD was not found to have an adverse effect on performance as shown by the low amounts of losses of separation. The use of conflict detection alerts on the CSD and full delegation responsibilities given to the UAS operator were found to create significantly reduced workload, significantly increased situation awareness and significantly easier communications between the UAS operator and air traffic controller without significantly increasing the amount of losses of separation.

  12. Unmanned aircraft system (UAS) delegation of separation in NextGen airspace

    NASA Astrophysics Data System (ADS)

    Kenny, Caitlin A.

    The purpose of this thesis was to determine the feasibility of unmanned aircraft systems (UAS) performing delegated separation in the national airspace system (NAS). Delegated separation is the transfer of responsibility for maintaining separation between aircraft or vehicles from air navigation service providers to the relevant pilot or flight operator. The effects of delegated separation and traffic display information level were collected through performance, workload, and situation awareness measures. The results of this study showed benefits related to the use of conflict detection alerts being shown on the UAS operator's cockpit situation display (CSD) and to the use of full delegation. Overall, changing the level of separation responsibility and adding conflict detection alerts on the CSD were not found to have an adverse effect on performance as shown by the low amounts of losses of separation. The use of conflict detection alerts on the CSD and full delegation responsibilities given to the UAS operator were found to create significantly reduced workload, significantly increased situation awareness and significantly easier communications between the UAS operator and air traffic controller without significantly increasing the amount of losses of separation.

  13. CISN ShakeAlert: Using early warnings for earthquakes in California

    NASA Astrophysics Data System (ADS)

    Vinci, M.; Hellweg, M.; Jones, L. M.; Khainovski, O.; Schwartz, K.; Lehrer, D.; Allen, R. M.; Neuhauser, D. S.

    2009-12-01

    Educated users who have developed response plans and procedures are just as important for an earthquake early warning (EEW) system as are the algorithms and computers that process the data and produce the warnings. In Japan, for example, the implementation of the EEW system which now provides advanced alerts of ground shaking included intense outreach efforts to both institutional and individual recipients. Alerts are now used in automatic control systems that stop trains, place sensitive equipment in safe mode and isolate hazards while the public takes cover. In California, the California Integrated Seismic Network (CISN) is now developing and implementing components of a prototype system for EEW, ShakeAlert. As this processing system is developed, we invite a suite of perspective users from critical industries and institutions throughout California to partner with us in developing useful ShakeAlert products and procedures. At the same time, we will support their efforts to determine and implement appropriate responses to an early warning of earthquake shaking. As a first step, in a collaboration with BART, we have developed a basic system allowing BART’s operation center to receive realtime ground shaking information from more than 150 seismic stations operating in the San Francisco Bay Area. BART engineers are implementing a display system for this information. Later phases will include the development of improved response procedures utilizing this information. We plan to continue this collaboration to include more sophisticated information from the prototype CISN ShakeAlert system.

  14. Improved Conflict Detection for Reducing Operational Errors in Air Traffic Control

    NASA Technical Reports Server (NTRS)

    Paielli, Russell A.; Erzberger, Hainz

    2003-01-01

    An operational error is an incident in which an air traffic controller allows the separation between two aircraft to fall below the minimum separation standard. The rates of such errors in the US have increased significantly over the past few years. This paper proposes new detection methods that can help correct this trend by improving on the performance of Conflict Alert, the existing software in the Host Computer System that is intended to detect and warn controllers of imminent conflicts. In addition to the usual trajectory based on the flight plan, a "dead-reckoning" trajectory (current velocity projection) is also generated for each aircraft and checked for conflicts. Filters for reducing common types of false alerts were implemented. The new detection methods were tested in three different ways. First, a simple flightpath command language was developed t o generate precisely controlled encounters for the purpose of testing the detection software. Second, written reports and tracking data were obtained for actual operational errors that occurred in the field, and these were "replayed" to test the new detection algorithms. Finally, the detection methods were used to shadow live traffic, and performance was analysed, particularly with regard to the false-alert rate. The results indicate that the new detection methods can provide timely warnings of imminent conflicts more consistently than Conflict Alert.

  15. The agile alert system for gamma-ray transients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.

    2014-01-20

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a newmore » algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.« less

  16. The AGILE Alert System for Gamma-Ray Transients

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  17. Implications of resolved hypoxemia on the utility of desaturation alerts sent from an anesthesia decision support system to supervising anesthesiologists.

    PubMed

    Epstein, Richard H; Dexter, Franklin

    2012-10-01

    Hypoxemia (oxygen saturation <90%) lasting 2 or more minutes occurs in 6.8% of adult patients undergoing noncardiac anesthesia in operating room settings. Alarm management functionality can be added to decision support systems (DSS) to send text alerts about vital signs outside specified thresholds, using data in anesthesia information management systems. We considered enhancing our DSS to send hypoxemia alerts to the text pagers of supervising anesthesiologists. As part of a voluntary application for an investigative device exemption from our IRB to implement such functionality, we evaluated the maximum potential utility of such an alert system. Pulse oximetry values (Spo(2)) were extracted from our anesthesia information management systems for all cases performed in our main operating rooms and ambulatory surgical center between September 1, 2011, and February 4, 2012 (n = 16,870). Hypoxemic episodes (Spo(2) < 90%) were characterized as either (a) lasting one or more minutes or (b) lasting 2 or more minutes. A single simulated "alert" was modeled as having been sent at the timestamp of the first (a) or the second (b) hypoxemic value. The hypoxemic episode was considered resolved at 1, 3, or 5 minutes after the time of the alert if the Spo(2) value was no longer below the 90% threshold. Two-sided 99% conservative confidence limits were calculated for the percentage of unresolved alerts at the 3 evaluation intervals and compared with 70%, the lower limit of an acceptable true alarm rate for clinical utility. There was at least 1 hypoxemic episode lasting 1 minute or longer in 23% of cases, and at least 1 episode lasting 2 minutes or longer in 8% of cases. Only 7% (99% confidence interval [CI] 6% to 8%) of the 1-minute hypoxemic episodes were unresolved after 3 minutes, and only 8% (99% CI 6%to 9%) of 2-minute episodes after 5 minutes (both P < 10(-6) in comparison with 70% minimum reliability rate). Low utility should be expected for a DSS sending hypoxemia alerts to supervising anesthesiologists, because nearly all hypoxemic episodes will have been resolved before arrival of the anesthesiologist in the operating room. These results suggest that the principal research focus should be on developing more sophisticated alerts and processes within rooms for the anesthesia care provider to initiate treatment promptly, to interpret or correct artifacts, and to make it easier to call for assistance via a rapid communication system.

  18. Improving safety and operational efficiency in residential care settings with WiFi-based localization.

    PubMed

    Doshi-Velez, Finale; Li, William; Battat, Yoni; Charrow, Ben; Curtis, Dorothy; Curthis, Dorothy; Park, Jun-geun; Hemachandra, Sachithra; Velez, Javier; Walsh, Cynthia; Fredette, Don; Reimer, Bryan; Roy, Nicholas; Teller, Seth

    2012-07-01

    To assess the effectiveness of a wireless network (WiFi-based) localization system (devices mounted on resident wheelchairs) in decreasing caretaker time spent searching for residents and providing alerts of residents going outdoors in a skilled nursing facility. A controlled study over two 2-month periods approved by the institutional review board. A long-term skilled nursing facility in Massachusetts specializing in multiple sclerosis previously instrumented with wireless network infrastructure. Nineteen residents and 9 staff members at the facility for the first 2-month period; 9 residents and 3 staff members at the facility for the second 2-month period. Software was installed on 4 staff computers to display the locations of residents enrolled in the study. This software was made available to enrolled staff for the second half of the first 2-month period and the entirety of the second 2-month study. In the second 2-month study, the software was modified to provide alerts if any 1 of 9 participating "high-risk"' residents went outdoors, and the accuracy of the alert system was evaluated. In the first 2-month study, 9 staff members recorded the amount of time it took them to locate participating residents (as and when needed during the course of their daily activities). In the second 2-month study, 3 staff members recorded whether outdoor-alerts correctly identified a resident leaving the building or if it was a false alarm. In both phases, participating staff members made frequent use of the system (44 searches and 215 outdoor alerts). Overall, the localization information decreased the average time needed to find residents by about two-thirds (from 311.1 seconds to 110.9 seconds). For outdoor alerts, the system had a false-alarm rate of 9.1% (under normal facility operations); systematic tests of the outdoor-alert system carried out by the authors had a false-negative, or missed-alarm, rate of 1.7%. Using timely resident location information can provide significant gains for both operational efficiency (finding residents) and enhanced resident safety (outdoor alerts). This approach may provide an inexpensive alternative for facilities that have sufficient wireless infrastructure; future work should assess its effectiveness in additional settings. Copyright © 2012 American Medical Directors Association. Published by Elsevier Inc. All rights reserved.

  19. Douglas flight deck design philosophy

    NASA Technical Reports Server (NTRS)

    Oldale, Paul

    1990-01-01

    The systems experience gained from 17 years of DC-10 operation was used during the design of the MD-11 to automate system operation and reduce crew workload. All functions, from preflight to shutdown at the termination of flight, require little input from the crew. The MD-11 aircraft systems are monitored for proper operation by the Aircraft Systems Controllers (ASC). In most cases, system reconfiguration as a result of a malfunction is automated. Manual input is required for irreversible actions such as engine shutdown, fuel dump, fire agent discharge, or Integrated Drive Generator (IDG) disconnect. During normal operations, when the cockpit is configured for flight, all annunciators on the overhead panel will be extinguished. This Dark Cockpit immediately confirms to the crew that the panels are correctly configured and that no abnormalities are present. Primary systems annunciations are shown in text on the Alert Area of the Engine and Alert Display (EAD). This eliminates the need to scan the overhead. The MD-11 aircraft systems can be manually controlled from the overhead area of the cockpit. The center portion of the overhead panel is composed of the primary aircraft systems panels, which include FUEL, AIR, Electrical (ELEC) and Hydraulic (HYD) systems, which are easily accessible from both flight crew positions. Each Aircraft Systems Controller (ASC) has two automatic channels and a manual mode. All rectangular lights are annunciators. All square lights are combined switches and annunciators called switch/lights. Red switch/lights on the overhead (Level 3 alerts) are for conditions requiring immediate crew action. Amber (Level 2 or Level 1 alerts) indicates a fault or switch out of position requiring awareness or crew interaction. Overhead switches used in normal operating conditions will illuminate blue when in use (Level 0 alerts) such as WING ANTI-ICE - ON. An overhead switch/light with BLACK LETTERING on an amber or red background indicates a system failure and that crew interaction is required. A switch/light with blue or amber lettering and a BLACK BACKGROUND indicates a switch out of normal position and that crew action is necessary only if the system is in manual operation.

  20. Adoption of medication alert systems in hospital outpatient departments in Taiwan.

    PubMed

    Kuo, Yu-Chun; Cheng, Shou-Hsia

    2017-06-01

    The adoption of medication alert systems in the health care sector varies among regions. In Taiwan, the health authority introduced policies in 2005 to encourage the adoption of medication alert systems in hospitals. This study aimed to understand the adoption of medication alert systems in the outpatient departments of hospitals in Taiwan using a nationwide survey. A questionnaire was developed and mailed to 380 accredited general hospitals in Taiwan in 2013. The information collected from the questionnaire concerning the outpatient department included (1) the time of adoption of a medication alert system; (2) the operation of individual alert functions: availability, management, and stability; and (3) hospital characteristics: accreditation level, teaching status, ownership, and number of beds. A total of 216 hospitals completed and returned the questionnaire, corresponding to a response rate of 56.8%. The adoption rate of medication alert systems in hospital outpatient departments increased from less than 10% in 1997-95.83% in 2012. Approximately two-thirds of the hospitals developed and maintained the alert systems independently or collaboratively with vendors. Teaching and large hospitals tended to develop more advanced alert functions such as drug-drug interaction functions. Improving the safety and quality of pharmaceutical services and meeting the policy requirements are reasons for hospitals to establish medication alert systems. The adoption rate of medication alert systems reached 95% in accredited general hospitals in Taiwan. Government policy and available health information professionals and vendors may somewhat contribute to the high adoption rate. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Lack of Sleep Could Be Trouble for CTE Students

    ERIC Educational Resources Information Center

    Scarpello, Gary

    2010-01-01

    Career and technical education (CTE) students find themselves in school environments using equipment and tools that could cause injury if mishandled. It is imperative that these students be wide awake and alert when operating these tools. But many adolescents are not getting the sleep they need to be refreshed and alert. Sleep restores brain…

  2. Use of Circadian Lighting System to improve night shift alertness and performance of NRC Headquarters Operations Officers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.; Morisseau, D.; Murphy, N.M.

    1995-04-01

    The Nuclear Regulatory Commission`s (NRC) Headquarters Operations Officers (HOOs) receive and respond to events reported in the nuclear industry on a 24-hour basis. The HOOs have reported reduced alertness on the night shift, leading to a potential deterioration in their on-shift cognitive performance during the early morning hours. For some HOOs, maladaptation to the night shift was also reported to be the principal cause of: (a) reduced alertness during the commute to and from work, (b) poor sleep quality, and (c) personal lifestyle problems. ShiftWork Systems, Inc. (SWS) designed and installed a Circadian Lighting System (CLS) at both the Bethesdamore » and Rockville HOO stations with the goal of facilitating the HOOs physiological adjustment to their night shift schedules. The data indicate the following findings: less subjective fatigue on night shifts; improved night shift alertness and mental performance; higher HOO confidence in their ability to assess event reports; longer, deeper and more restorative day sleep after night duty shifts; swifter adaptation to night work; and a safer commute, particularly for those with extensive drives.« less

  3. Experimental evaluation of candidate graphical microburst alert displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig R.; Hansman, R. John

    1992-01-01

    A piloted flight simulator experiment was conducted to evaluate issues related to the display of microburst alerts on electronic cockpit instrumentation. Issues addressed include display clarity, usefulness of multilevel microburst intensity information, and whether information from multiple sensors should be presented separately or 'fused' into combined alerts. Nine active airline pilots of 'glass cockpit' aircraft participated in the study. Microburst alerts presented on a moving map display were found to be visually clear and useful to pilots. Also, multilevel intensity information coded by colors or patterns was found to be important for decision making purposes. Pilot opinion was mixed on whether to 'fuse' data from multiple sensors, and some resulting design tradeoffs were identified. The positional information included in the graphical alert presentation was found useful by the pilots for planning lateral missed approach maneuvers, but may result in deviations which could interfere with normal airport operations. A number of flight crew training issues were also identified.

  4. ElarmS Earthquake Early Warning System: 2017 Performance and New ElarmS Version 3.0 (E3)

    NASA Astrophysics Data System (ADS)

    Chung, A. I.; Henson, I. H.; Allen, R. M.; Hellweg, M.; Neuhauser, D. S.

    2017-12-01

    The ElarmS earthquake early warning (EEW) system has been successfully detecting earthquakes throughout California since 2007. ElarmS version 2.0 (E2) is one of the three algorithms contributing alerts to ShakeAlert, a public EEW system being developed by the USGS in collaboration with UC Berkeley, Caltech, University of Washington, and University of Oregon. E2 began operating in test mode in the Pacific Northwest in 2013, and since April of this year E2 has been contributing real-time alerts from Oregon and Washington to the ShakeAlert production prototype system as part of the ShakeAlert roll-out throughout the West Coast. Since it began operating west-coast-wide, E2 has correctly alerted on 5 events that matched ANSS catalog events with M≥4, missed 1 event with M≥4, and incorrectly created alerts for 5 false events with M≥4. The most recent version of the algorithm, ElarmS version 3.0 (E3), is a significant improvement over E2. It addresses some of the most problematic causes of false events for which E2 produced alerts, without impacting reliability in terms of matched and missed events. Of the 5 false events that were generated by E2 since April, 4 would have been suppressed by E3. In E3, we have added a filterbank teleseismic filter. By analyzing the amplitude of the waveform filtered in various passbands, it is possible to distinguish between local and teleseismic events. We have also added a series of checks to validate triggers and filter out spurious and S-wave triggers. Additional improvements to the waveform associator also improve detections. In this presentation, we describe the improvements and compare the performance of the current production (E2) and development (E3) versions of ElarmS over the past year. The ShakeAlert project is now working through a streamlining process to identify the best components of various algorithms and merge them. The ElarmS team is participating in this effort and we anticipate that much of E3 will continue in the final system.

  5. Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project: Terminal Operations HITL 1: Primary Results

    NASA Technical Reports Server (NTRS)

    Rorie, Conrad; Fern, Lisa; Monk, Kevin; Roberts, Zach; Brandt, Summer

    2017-01-01

    This presentation covers the primary results of the Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project Terminal Operations Foundational Human-in-the-Loop (HITL) simulation. The study tasked 16 pilots (half with manned piloting experience, and the other half with unmanned piloting experience) with maintaining "well clear" from other traffic while performing three different types of approaches into the Santa Rosa airport. A detect and avoid (DAA) system was provided to pilots to assist their ability to manage separation. The DAA system used in this test conformed to the criteria defined by RTCA Special Committee 228 (SC-228) in their Phase 1 Minimum Operational Performance Standards (MOPS) for UAS intending to operate in the NAS. The Phase 1 system was not designed to account for terminal operations, focusing instead on en route operations. To account for this, three different alerting and guidance configurations were presently tested in order to determine their effect on pilots operating the system in the terminal area. Results indicated that pilots with the alerting and guidance condition that provided the least amount of assistance (fewer alert levels and guidance types) experienced slightly increased pilot response times and rates of losses of separation. Additional data is presented on the effects of approach type and descriptive data on pilot maneuver preferences and ATC interoperability.

  6. Evaluation of the attention network test using vibrotactile stimulations.

    PubMed

    Salzer, Yael; Oron-Gilad, Tal; Henik, Avishai

    2015-06-01

    We report a vibrotactile version of the attention network test (ANT)-the tactile ANT (T-ANT). It has been questioned whether attentional components are modality specific or not. The T-ANT explores alertness, orienting, cognitive control, and their relationships, similar to its visual counterpart, in the tactile modality. The unique features of the T-ANT are in utilizing stimuli on a single plane-the torso-and replacing the original imperative flanker task with a tactile Simon task. Subjects wore a waist belt mounted with two vibrotactile stimulators situated on the back and positioned to the right and left of the spinal column. They responded by pressing keys with their right or left hand in reaction to the type of vibrotactile stimulation (pulsed/continuous signal). On a single trial, an alerting tone was followed by a short tactile (informative/noninformative) peripheral cue and an imperative tactile Simon task target. The T-ANT was compared with a variant of the ANT in which the flanker task was replaced with a visual Simon task. Experimental data showed effects of orienting over control only when the peripheral cues were informative. In contrast to the visual task, interactions between alertness and control or alertness and orienting were not found in the tactile task. A possible rationale for these results is discussed. The T-ANT allows examination of attentional processes among patients with tactile attentional deficits and patients with eyesight deficits who cannot take part in visual tasks. Technological advancement would enable implementation of the T-ANT in brain-imaging studies.

  7. 49 CFR 1562.3 - Operating requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... minimum, must: (1) Identify and provide contact information for the airport's airport security coordinator... and non-operational hours; and (ii) Alert the aircraft owner(s) and operator(s), the airport operator...) U.S. Armed forces, law enforcement, and aeromedical services aircraft. An individual may operate a U...

  8. 49 CFR 1562.3 - Operating requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... minimum, must: (1) Identify and provide contact information for the airport's airport security coordinator... and non-operational hours; and (ii) Alert the aircraft owner(s) and operator(s), the airport operator...) U.S. Armed forces, law enforcement, and aeromedical services aircraft. An individual may operate a U...

  9. 49 CFR 1562.3 - Operating requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... minimum, must: (1) Identify and provide contact information for the airport's airport security coordinator... and non-operational hours; and (ii) Alert the aircraft owner(s) and operator(s), the airport operator...) U.S. Armed forces, law enforcement, and aeromedical services aircraft. An individual may operate a U...

  10. 49 CFR 1562.3 - Operating requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... minimum, must: (1) Identify and provide contact information for the airport's airport security coordinator... and non-operational hours; and (ii) Alert the aircraft owner(s) and operator(s), the airport operator...) U.S. Armed forces, law enforcement, and aeromedical services aircraft. An individual may operate a U...

  11. 49 CFR 1562.3 - Operating requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... minimum, must: (1) Identify and provide contact information for the airport's airport security coordinator... and non-operational hours; and (ii) Alert the aircraft owner(s) and operator(s), the airport operator...) U.S. Armed forces, law enforcement, and aeromedical services aircraft. An individual may operate a U...

  12. The COMESEP Alert System

    NASA Astrophysics Data System (ADS)

    Crosby, Norma; Veronig, Astrid; Rodriguez, Luciano; Vrsnak, Bojan; Vennerstrom, Susanne; Malandraki, Olga; Dalla, Silvia; Srivastava, Nandita; Hesse, Michael; Odstrcil, Dusan; Robbrecht, Eva

    2014-05-01

    Tools for forecasting geomagnetic storms and solar energetic particle (SEP) radiation storms have been developed under the three-year EU FP7 COMESEP (COronal Mass Ejections and Solar Energetic Particles) collaborative project. To enhance our understanding of the 3D kinematics and interplanetary propagation of coronal mass ejections (CMEs), the structure, propagation and evolution of CMEs have been investigated. In parallel, the sources and propagation of SEPs have been examined and modeled. During the third year of the COMESEP project the produced tools have been validated and implemented into an operational space weather alert system. The COMESEP Alert System provides notifications for the space weather community. To achieve this the system relies on both models and data, the latter including near real-time data as well as historical data. Geomagnetic and SEP radiation storm alerts are based on the COMESEP definition of risk. The COMESEP Alert System has recently been launched. Receiving COMESEP alerts are free of charge, but registration is required. For more information see the project website (http://www.comesep.eu/). This work has received funding from the European Commission FP7 Project COMESEP (263252).

  13. The Seismic Alert System of Mexico (SASMEX): Performance and Evolution

    NASA Astrophysics Data System (ADS)

    Espinosa Aranda, J.

    2013-05-01

    Originally the Seismic Alert System of Mexico (SASMEX) was proposed to integrate the Seismic Alert System of Mexico City (SAS), operating since 1991, with the Seismic Alert System of Oaxaca City (SASO), in services since 2003. And today, after the intense big earthquake activity observed in our world during 2010 and 2011, local governments of Mexico City, Oaxaca Estate, and the Mexican Ministry of the Interior have been promoting the expansion of this technological EEW development. Until 2012 SASMEX better coverage includes 48 new field seismic sensors (FS) deployed over the seismic region of Jalisco, Colima, Michoacan and Puebla, with someone enhancements over Guerrero and Oaxaca, to reach 97 FS. During 2013, 35 new FS has been proposed to SASMEX enhancements covering the Chiapas and Veracruz seismic regions. The SASMEX, with the support of the Mexico Valley Broadcasters Association (ARVM) since 1993, automatically issue Public and Preventive earthquake early warning signals in the Cities of Mexico, Toluca, Acapulco, Chilpancingo, and Oaxaca. The seismic warning range in each case is seated in accordance with local Civil Protection Authorities: Public Alert, if they expect strong earthquake effects, and Preventive Alert one, the effect could be moderated. Now the SASMEX warning time opportunity could be different to the 60 sec. average typically generated when SAS warned earthquake effects coming from Guerrero to Mexico City valley. Mexican EEW issued today reach: 16 Public and 62 Preventive Alert in Mexico City; 25 Public and 19 Preventive Alerts in Oaxaca City; also 14 Public and 4 Preventive Alerts in Acapulco; 14 Public and 5 Preventive Alerts in Chilpancingo. The earthquakes events registered by SASMEX FS until now reach 3448. With the support of private and Federal telecommunications infrastructure like, TELMEX, Federal Electric Commission, and the Mexican Security Ministry, it was developed a redundant communication system with pads to link the different Cities, trough VHF and UHF radio signals, Fiber Optics, and Satellite technologies, to reach more reliability and availability SASMEX functions and services. To increase the seismic early warning efficiency the Mexico City Historical Center Authorities, promoted the installation of the NOAA VHF radio transmitters system to cover the Mexico City valley, operating with the Specific Area Message Encoding (SAME) called NWR-SAME, and with the Emergency Alert Systems (EAS) protocol of United States. As an enhancement of the NOAA receiver protocol, it was innovated to permit fast Public Alert issue, in no more than 2 sec. The new receiver applied in Mexico is called SARMEX™. Local and federal authorities acquired 90,000 SARMEX™ receivers to be distributed manly in public schools of Mexican cities covered by the SASMEX™ signals; the measure with the aim to promote better natural hazard prevention attitude in the Mexican young population segment.

  14. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...

  15. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...

  16. 47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...

  17. An Investigation of Alerting and Prioritization Criteria for Sense and Avoid (SAA)

    DTIC Science & Technology

    2013-10-01

    TECHNICAL REPORT RDMR-TM-13-01 AN INVESTIGATION OF ALERTING AND PRIORITIZATION CRITERIA FOR SENSE AND AVOID ( SAA ...OFFICIAL ENDORSEMENT OR APPROVAL OF THE USE OF SUCH COMMERCIAL HARDWARE OR SOFTWARE . i/ii (Blank) REPORT DOCUMENTATION PAGE Form Approved...burden to Washington Headquarters Services , Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington

  18. Airport Traffic Conflict Detection and Resolution Algorithm Evaluation

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Chartrand, Ryan C.; Wilson, Sara R.; Commo, Sean A.; Ballard, Kathryn M.; Otero, Sharon D.; Barker, Glover D.

    2016-01-01

    Two conflict detection and resolution (CD&R) algorithms for the terminal maneuvering area (TMA) were evaluated in a fast-time batch simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center. One CD&R algorithm, developed at NASA, was designed to enhance surface situation awareness and provide cockpit alerts of potential conflicts during runway, taxi, and low altitude air-to-air operations. The second algorithm, Enhanced Traffic Situation Awareness on the Airport Surface with Indications and Alerts (SURF IA), was designed to increase flight crew awareness of the runway environment and facilitate an appropriate and timely response to potential conflict situations. The purpose of the study was to evaluate the performance of the aircraft-based CD&R algorithms during various runway, taxiway, and low altitude scenarios, multiple levels of CD&R system equipage, and various levels of horizontal position accuracy. Algorithm performance was assessed through various metrics including the collision rate, nuisance and missed alert rate, and alert toggling rate. The data suggests that, in general, alert toggling, nuisance and missed alerts, and unnecessary maneuvering occurred more frequently as the position accuracy was reduced. Collision avoidance was more effective when all of the aircraft were equipped with CD&R and maneuvered to avoid a collision after an alert was issued. In order to reduce the number of unwanted (nuisance) alerts when taxiing across a runway, a buffer is needed between the hold line and the alerting zone so alerts are not generated when an aircraft is behind the hold line. All of the results support RTCA horizontal position accuracy requirements for performing a CD&R function to reduce the likelihood and severity of runway incursions and collisions.

  19. Behavioral Modification of Intraoperative Hyperglycemia Management with a Novel Real-time Audiovisual Monitor.

    PubMed

    Sathishkumar, Subramanian; Lai, Manda; Picton, Paul; Kheterpal, Sachin; Morris, Michelle; Shanks, Amy; Ramachandran, Satya Krishna

    2015-07-01

    Hyperglycemia, defined as blood glucose (BG) levels above 200 mg/dl (11.1 mM), is associated with increased postoperative morbidity. Yet, the treatment standard for intraoperative glycemic control is poorly defined for noncardiac surgery. Little is known of the interindividual treatment variability or methods to modify intraoperative glycemic management behaviors. AlertWatch (AlertWatch, USA) is a novel audiovisual alert system that serves as a secondary patient monitor for use in operating rooms. The authors evaluated the influence of use of AlertWatch on intraoperative glycemic management behavior. AlertWatch displays historical patient data (risk factors and laboratory results) from multiple networked information systems, combined with the patient's live physiologic data. The authors extracted intraoperative data for 19 months to evaluate the relationship between AlertWatch usage and initiation of insulin treatment for hyperglycemia. Outcome associations were adjusted for physical status, case duration, procedural complexity, emergent procedure, fasting BG value, home insulin therapy, patient age, and primary anesthetist. Overall, 2,341 patients had documented intraoperative hyperglycemia. Use of AlertWatch (791 of 2,341; 33.5%) was associated with 55% increase in insulin treatment (496 of 791 [62.7%] with and 817 of 1,550 [52.7%] without AlertWatch; adjusted odds ratio [95% CI], 1.55 [1.23 to 1.95]; P < 0.001) and 44% increase in BG recheck after insulin administration (407 of 791 [51.5%] with AlertWatch and 655 of 1,550 [42.3%] in controls; adjusted odds ratio [95% CI], 1.44 [1.14 to 1.81]; P = 0.002). AlertWatch is associated with a significant increase in desirable intraoperative glycemic management behavior and may help achieve tighter intraoperative glycemic control.

  20. Mobile machine hazardous working zone warning system

    DOEpatents

    Schiffbauer, William H.; Ganoe, Carl W.

    1999-01-01

    A warning system is provided for a mobile working machine to alert an individual of a potentially dangerous condition in the event the individual strays into a hazardous working zone of the machine. The warning system includes a transmitter mounted on the machine and operable to generate a uniform magnetic field projecting beyond an outer periphery of the machine in defining a hazardous working zone around the machine during operation thereof. A receiver, carried by the individual and activated by the magnetic field, provides an alarm signal to alert the individual when he enters the hazardous working zone of the machine.

  1. Mobile machine hazardous working zone warning system

    DOEpatents

    Schiffbauer, W.H.; Ganoe, C.W.

    1999-08-17

    A warning system is provided for a mobile working machine to alert an individual of a potentially dangerous condition in the event the individual strays into a hazardous working zone of the machine. The warning system includes a transmitter mounted on the machine and operable to generate a uniform magnetic field projecting beyond an outer periphery of the machine in defining a hazardous working zone around the machine during operation. A receiver, carried by the individual and activated by the magnetic field, provides an alarm signal to alert the individual when he enters the hazardous working zone of the machine. 3 figs.

  2. Crew factors in flight operations IX : effects of planned cockpit rest on crew performance and alertness in long-haul operations

    DOT National Transportation Integrated Search

    1994-07-01

    This report is the ninth in a series on physiological and psychological effects of flight operations on flight crews, and on the operational significance of these effects. Long-haul flight operations often involve rapid multiple time-zone changes, sl...

  3. Wireless alerting system using vibration for vehicles dashboard

    NASA Astrophysics Data System (ADS)

    Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.

    2017-11-01

    This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.

  4. A randomized trial of automated electronic alerts demonstrating improved reimbursable anesthesia time documentation.

    PubMed

    Freundlich, Robert E; Barnet, Caryn S; Mathis, Michael R; Shanks, Amy M; Tremper, Kevin K; Kheterpal, Sachin

    2013-03-01

    To investigate whether alerting providers to errors results in improved documentation of reimbursable anesthesia care. Prospective randomized controlled trial. Operating room (OR) of a university hospital. Anesthesia cases were evaluated to determine whether they met the definition for appropriate anesthesia start time over 4 separate, 45-day calendar cycles: the pre-study period, study period, immediate post-study period, and 3-year follow-up period. During the study period, providers were randomly assigned to either a control or an alert group. Providers in the alert cohort received an automated alphanumeric page if the anesthesia start time occurred concurrently with the patient entering the OR, or more than 30 minutes before entering the OR. Three years after the intervention period, overall compliance was analyzed to assess learned behavior. Baseline compliance was 33% ± 5%. During the intervention period, providers in the alert group showed 87% ± 6% compliance compared with 41% ± 7% compliance in the control group (P < 0.001). Long-term follow-up after cessation of the alerts showed 85% ± 4% compliance. Automated electronic reminders for time-based billing charges are effective and result in improved ongoing reimbursement. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. The Common Alerting Protocol (CAP) adaption in National Early Warning Alerting Systems of China

    NASA Astrophysics Data System (ADS)

    Li, Chao

    2017-04-01

    The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In China, from local communities to entire nations, there was a patchwork of specialized hazard public alerting systems. And each system was often designed just for certain emergency situations and for certain communications media. Application took place in the NEWAS (National Early Warning Alerting Systems) [2]project where CAP serves as central message to integrate all kind of hazard situations, including the natural calamity, accident disaster, public health emergency , social safety etc. Officially operated on May 2015, NEWAS now has completed docking work with 14 departments including civil administration, safety supervision, forestry, land, water conservancy, earthquake, traffic, meteorology, agriculture, tourism, food and drug supervision, public security and oceanic administration. Thus, several items in CAP has been modified, redefined and extended according to the various grading standards and publishing strategies, as well as the characteristics of Chinese Geocoding. NEWAS successfully delivers information to end users through 4 levels (i.e. State, province, prefecture and county) structure and by various means. [1] CAP, http://www.oasis-emergency.org/cap [2] http://www.12379.cn/

  6. Speech Auditory Alerts Promote Memory for Alerted Events in a Video-Simulated Self-Driving Car Ride.

    PubMed

    Nees, Michael A; Helbein, Benji; Porter, Anna

    2016-05-01

    Auditory displays could be essential to helping drivers maintain situation awareness in autonomous vehicles, but to date, few or no studies have examined the effectiveness of different types of auditory displays for this application scenario. Recent advances in the development of autonomous vehicles (i.e., self-driving cars) have suggested that widespread automation of driving may be tenable in the near future. Drivers may be required to monitor the status of automation programs and vehicle conditions as they engage in secondary leisure or work tasks (entertainment, communication, etc.) in autonomous vehicles. An experiment compared memory for alerted events-a component of Level 1 situation awareness-using speech alerts, auditory icons, and a visual control condition during a video-simulated self-driving car ride with a visual secondary task. The alerts gave information about the vehicle's operating status and the driving scenario. Speech alerts resulted in better memory for alerted events. Both auditory display types resulted in less perceived effort devoted toward the study tasks but also greater perceived annoyance with the alerts. Speech auditory displays promoted Level 1 situation awareness during a simulation of a ride in a self-driving vehicle under routine conditions, but annoyance remains a concern with auditory displays. Speech auditory displays showed promise as a means of increasing Level 1 situation awareness of routine scenarios during an autonomous vehicle ride with an unrelated secondary task. © 2016, Human Factors and Ergonomics Society.

  7. CAUSE Resiliency (West Coast) Experiment Final Report

    DTIC Science & Technology

    2012-10-01

    implemented in BCeMap and can therefore consume alerting messages direct from MASAS. This would solve the issue with the update frequency and speed of the...in production for use by the Provincial Emergency Operations Centres and brings together multiple static layers together with several dynamic data...executive order established the requirement for an “effective, reliable, integrated, flexible, and comprehensive system to alert and warn the

  8. Experimental Study of Collision Detection Schema Used by Pilots During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1996-01-01

    An experimental flight simulator study was conducted to examine the mental alerting logic and thresholds used by subjects to issue an alert and execute an avoidance maneuver. Subjects flew a series of autopilot landing approaches with traffic on a closely-spaced parallel approach; during some runs, the traffic would deviate towards the subject and the subject was to indicate the point when they recognized the potential traffic conflict, and then indicate a direction of flight for an avoidance maneuver. A variety of subjects, including graduate students, general aviation pilots and airline pilots, were tested. Five traffic displays were evaluated, with a moving map TCAS-type traffic display as a baseline. A side-task created both high and low workload situations. Subjects appeared to use the lateral deviation of the intruder aircraft from its approach path as the criteria for an alert regardless of the display available. However, with displays showing heading and/or trend information, their alerting thresholds were significantly lowered. This type of range-only schema still resulted in many near misses, as a high convergence rate was often established by the time of the subject's alert. Therefore, the properties of the intruder's trajectory had the greatest effect on the resultant near miss rate; no display system reliably caused alerts timely enough for certain collision avoidance. Subjects' performance dropped significantly on a side-task while they analyzed the need for an alert, showing alert generation can be a high workload situation at critical times. No variation was found between subjects with and with out piloting experience. These results suggest the design of automatic alerting systems should take into account the range-type alerting schema used by the human, such that the rationale for the automatic alert should be obvious to, and trusted by, the operator. Although careful display design may help generate pilot/automation trust, issues such as user non-conformance to automatically generated commands can remain a possibility.

  9. Statistical analysis of environmental monitoring data: does a worst case time for monitoring clean rooms exist?

    PubMed

    Cundell, A M; Bean, R; Massimore, L; Maier, C

    1998-01-01

    To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.

  10. New Space Weather Systems Under Development and Their Contribution to Space Weather Management

    NASA Astrophysics Data System (ADS)

    Tobiska, W.; Bouwer, D.; Schunk, R.; Garrett, H.; Mertens, C.; Bowman, B.

    2008-12-01

    There have been notable successes during the past decade in the development of operational space environment systems. Examples include the Magnetospheric Specification Model (MSM) of the Earth's magnetosphere, 2000; SOLAR2000 (S2K) solar spectral irradiances, 2001; High Accuracy Satellite Drag Model (HASDM) neutral atmosphere densities, 2004; Global Assimilation of Ionospheric Measurements (GAIM) ionosphere specification, 2006; Hakamada-Akasofu-Fry (HAF) solar wind parameters, 2007; Communication Alert and Prediction System (CAPS) ionosphere, high frequency radio, and scintillation S4 index prediction, 2008; and GEO Alert and Prediction System (GAPS) geosynchronous environment satellite charging specification and forecast, 2008. Operational systems that are in active operational implementation include the Jacchia-Bowman 2006/2008 (JB2006/2008) neutral atmosphere, 2009, and the Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) aviation radiation model using the Radiation Alert and Prediction System (RAPS), 2010. U.S. national agency and commercial assets will soon reach a state where specification and prediction will become ubiquitous and where coordinated management of the space environment and space weather will become a necessity. We describe the status of the CAPS, GAPS, RAPS, and JB2008 operational development. We additionally discuss the conditions that are laying the groundwork for space weather management and estimate the unfilled needs as we move beyond specification and prediction efforts.

  11. Influence of satellite alerts on the efficiency of aircraft monitoring of maritime oil pollution in German waters

    NASA Astrophysics Data System (ADS)

    Helmke, Peer; Baschek, Björn; Hunsänger, Thomas; Kranz, Susanne

    2014-10-01

    For detecting accidental and illegal pollution by mineral oil, the German exclusive economic zone and surrounding waters have been monitored by aircraft operationally for more than 25 years. Aircraft surveillance uses predominantly Side-Looking-Airborne-Radar for visualization of the effect of oil to smoothen capillary waves. A set of near range sensors complements the remote sensing data available for the human operator to classify the detected features as "mineral oil", "natural phenomenon", "other substance" or "unknown" pollution. Today, as an add-on to aerial surveillance, the German Central Command of Maritime Emergencies uses the operational satellite service "CleanSeaNet" provided by the European Maritime Safety Agency: Radar satellite data is analyzed in near real time and alerts of potential pollution are sent out. Shortly after receiving the results, aircraft surveillance flights are started by the 3rd Naval Air Wing and the locations of the satellite alerts are checked. Thus, a combined system of satellite and aerial surveillance is in place. The German Federal Institute of Hydrology, BfG, has access to the data of the pollution events detected during these flights and the corresponding meta-data of flights and satellite images. In this work, a period of two years of this data is analyzed. The probability to detect pollutions is evaluated for (A) flight missions associated with satellite scenes, and (B) additional flights performed independently from satellite scenes. Thus, the influence of satellite alerts on the efficiency of aircraft monitoring is investigated. Coverage and coordination of the monitoring by aircraft and satellite are assessed and implications for the operational monitoring are discussed.

  12. Distillation sequence for the purification and recovery of hydrocarbons

    DOEpatents

    Reyneke, Rian; Foral, Michael; Papadopoulos, Christos G.; Logsdon, Jeffrey S.; Eng, Wayne W. Y.; Lee, Guang-Chung; Sinclair, Ian

    2007-12-25

    This invention is an improved distillation sequence for the separation and purification of ethylene from a cracked gas. A hydrocarbon feed enters a C2 distributor column. The top of the C2 distributor column is thermally coupled to an ethylene distributor column, and the bottoms liquid of a C2 distributor column feeds a deethanizer column. The C2 distributor column utilizes a conventional reboiler. The top of the ethylene distributor is thermally coupled with a demethanizer column, and the bottoms liquid of the ethylene distributor feeds a C2 splitter column. The ethylene distributor column utilizes a conventional reboiler. The deethanizer and C2 splitter columns are also thermally coupled and operated at a substantially lower pressure than the C2 distributor column, the ethylene distributor column, and the demethanizer column. Alternatively, a hydrocarbon feed enters a deethanizer column. The top of the deethanizer is thermally coupled to an ethylene distributor column, and the ethylene distributor column utilizes a conventional reboiler. The top of the ethylene distributor column is thermally coupled with a demethanizer column, and the bottoms liquid of the ethylene distributor column feeds a C2 splitter column. The C2 splitter column operates at a pressure substantially lower than the ethylene distributor column, the demethanizer column, and the deethanizer column.

  13. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    An analytical study of reports relating to cockpit altitude alert systems was performed. A recent change in the Federal Air Regulation permits the system to be modified so that the alerting signal approaching altitude has only a visual component; the auditory signal would continue to be heard if a deviation from an assigned altitude occurred. Failure to observe altitude alert signals and failure to reset the system were the commonest cause of altitude deviations related to this system. Cockpit crew distraction was the most frequent reason for these failures. It was noted by numerous reporters that the presence of altitude alert system made them less aware of altitude; this lack of altitude awareness is discussed. Failures of crew coordination were also noted. It is suggested that although modification of the altitude alert system may be highly desirable in short-haul aircraft, it may not be desirable for long-haul aircraft in which cockpit workloads are much lower for long periods of time. In these cockpits, the aural alert approaching altitudes is perceived as useful and helpful. If the systems are to be modified, it appears that additional emphasis on altitude awareness during recurrent training will be necessary; it is also possible that flight crew operating procedures during climb and descent may need examination with respect to monitoring responsibilities. A selection of alert bulletins and responses to them is presented.

  14. 40 CFR 63.11583 - What are my monitoring requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... preparation operation are in target HAP service: (a) Operate a bag leak detection system with alarm that will alert operators of a leak in the control device filter material. If a bag leak detection system with... install, calibrate, operate, and maintain each bag leak detection system and alarm according to...

  15. 49 CFR 392.3 - Ill or fatigued operator.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... VEHICLES General § 392.3 Ill or fatigued operator. No driver shall operate a commercial motor vehicle, and a motor carrier shall not require or permit a driver to operate a commercial motor vehicle, while the driver's ability or alertness is so impaired, or so likely to become impaired, through fatigue...

  16. Unit operations for gas-liquid mass transfer in reduced gravity environments

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Allen, David T.

    1992-01-01

    Basic scaling rules are derived for converting Earth-based designs of mass transfer equipment into designs for a reduced gravity environment. Three types of gas-liquid mass transfer operations are considered: bubble columns, spray towers, and packed columns. Application of the scaling rules reveals that the height of a bubble column in lunar- and Mars-based operations would be lower than terrestrial designs by factors of 0.64 and 0.79 respectively. The reduced gravity columns would have greater cross-sectional areas, however, by factors of 2.4 and 1.6 for lunar and Martian settings. Similar results were obtained for spray towers. In contract, packed column height was found to be nearly independent of gravity.

  17. Commercial Mobile Alert Service (CMAS) Scenarios

    DTIC Science & Technology

    2012-05-01

    Commercial Mobile Alert Service (CMAS) Scenarios The WEA Project Team May 2012 SPECIAL REPORT CMU/SEI-2012-SR-020 CERT® Division, Software ...Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally...DISTRIBUTES IT “AS IS.” References herein to any specific commercial product, process, or service by trade name, trade mark, manufacturer, or otherwise

  18. Impact-based earthquake alerts with the U.S. Geological Survey's PAGER system: what's next?

    USGS Publications Warehouse

    Wald, D.J.; Jaiswal, K.S.; Marano, K.D.; Garcia, D.; So, E.; Hearne, M.

    2012-01-01

    In September 2010, the USGS began publicly releasing earthquake alerts for significant earthquakes around the globe based on estimates of potential casualties and economic losses with its Prompt Assessment of Global Earthquakes for Response (PAGER) system. These estimates significantly enhanced the utility of the USGS PAGER system which had been, since 2006, providing estimated population exposures to specific shaking intensities. Quantifying earthquake impacts and communicating estimated losses (and their uncertainties) to the public, the media, humanitarian, and response communities required a new protocol—necessitating the development of an Earthquake Impact Scale—described herein and now deployed with the PAGER system. After two years of PAGER-based impact alerting, we now review operations, hazard calculations, loss models, alerting protocols, and our success rate for recent (2010-2011) events. This review prompts analyses of the strengths, limitations, opportunities, and pressures, allowing clearer definition of future research and development priorities for the PAGER system.

  19. The Effects of Ultra-Long-Range Flights on the Alertness and Performance of Aviators

    NASA Technical Reports Server (NTRS)

    Caldwell, John A.; Mallis, Melissa M.; Colletti, Laura M.; Oyung, Raymond L.; Brandt, Summer L.; Arsintescu, Lucia; DeRoshia, Charlie W.; Reduta-Rojas, Dinah D.; Chapman, Patrick M.

    2006-01-01

    This investigation assessed the impact of ultra-long-range (ULR) simulator flights, departing either in the morning or late evening, on the alertness and performance of 17 commercial aviators. Immediately prior to and throughout each flight, alertness and performance were assessed via a computerized test of sustained attention, subjective questionnaires, and "hand-flying" tasks. There were fatigue-related effects on the majority of assessments, and the nature of these effects was consistent across the vigilance and self-report measures. However, the operational "hand-flying" manuevers proved insensitive to the impact of fatigue probably due to procedural factors. Regardless, the results of the present study suggest that fatigue associated with prolonged wakefulness in ULR flight operations will interact with flight schedules due to circadian and homeostatic influences. In this study, the pilots departing at night were at a greater initial disadvantage (during cruise) than pilots who departed earlier in the day; whereas those who departed earlier tended to be most impaired towards the end of the flight prior to landing. In real-world operations, airlines should consider the ramifications of flight schedules and what is known about human sleep and circadian rhythms to optimize safety.

  20. Engine monitoring display study

    NASA Technical Reports Server (NTRS)

    Hornsby, Mary E.

    1992-01-01

    The current study is part of a larger NASA effort to develop displays for an engine-monitoring system to enable the crew to monitor engine parameter trends more effectively. The objective was to evaluate the operational utility of adding three types of information to the basic Boeing Engine Indicating and Crew Alerting System (EICAS) display formats: alphanumeric alerting messages for engine parameters whose values exceed caution or warning limits; alphanumeric messages to monitor engine parameters that deviate from expected values; and a graphic depiction of the range of expected values for current conditions. Ten training and line pilots each flew 15 simulated flight scenarios with five variants of the basic EICAS format; these variants included different combinations of the added information. The pilots detected engine problems more quickly when engine alerting messages were included in the display; adding a graphic depiction of the range of expected values did not affect detection speed. The pilots rated both types of alphanumeric messages (alert and monitor parameter) as more useful and easier to interpret than the graphic depiction. Integrating engine parameter messages into the EICAS alerting system appears to be both useful and preferred.

  1. ALERT: Revatio is another brand name for sildenafil.

    PubMed

    Koczmara, Christine; Hyland, Sylvia; Greenall, Julie

    2009-01-01

    In this column, the authors highlight a medication incident that occurred with Revatio (sildenafil), along with the learnings and recommendations from a previously published ISMP Canada Safety Bulletin. It is well-known to health care practitioners that use of nitroglycerin therapy is contraindicated in patients taking sildenafil (commonly known as Viagra). Many health care practitioners may be unaware that sildenafil is also marketed under the brand name Revatio for treatment of primary pulmonary hypertension or pulmonary hypertension secondary to connective tissue disease. The following incident signals the need to heighten the awareness that Revatio is a brand name for sildenafil.

  2. Generalized Philosophy of Alerting with Applications for Parallel Approach Collision Prevention

    NASA Technical Reports Server (NTRS)

    Winder, Lee F.; Kuchar, James K.

    2000-01-01

    The goal of the research was to develop formal guidelines for the design of hazard avoidance systems. An alerting system is automation designed to reduce the likelihood of undesirable outcomes that are due to rare failures in a human-controlled system. It accomplishes this by monitoring the system, and issuing warning messages to the human operators when thought necessary to head off a problem. On examination of existing and recently proposed logics for alerting it appears that few commonly accepted principles guide the design process. Different logics intended to address the same hazards may take disparate forms and emphasize different aspects of performance, because each reflects the intuitive priorities of a different designer. Because performance must be satisfactory to all users of an alerting system (implying a universal meaning of acceptable performance) and not just one designer, a proposed logic often undergoes significant piecemeal modification before gamma general acceptance. This report is an initial attempt to clarify the common performance goals by which an alerting system is ultimately judged. A better understanding of these goals will hopefully allow designers to reach the final logic in a quicker, more direct and repeatable manner. As a case study, this report compares three alerting logics for collision prevention during independent approaches to parallel runways, and outlines a fourth alternative incorporating elements of the first three, but satisfying stated requirements. Three existing logics for parallel approach alerting are described. Each follows from different intuitive principles. The logics are presented as examples of three "philosophies" of alerting system design.

  3. EEG quantification of alertness: methods for early identification of individuals most susceptible to sleep deprivation

    NASA Astrophysics Data System (ADS)

    Berka, Chris; Levendowski, Daniel J.; Westbrook, Philip; Davis, Gene; Lumicao, Michelle N.; Olmstead, Richard E.; Popovic, Miodrag; Zivkovic, Vladimir T.; Ramsey, Caitlin K.

    2005-05-01

    Electroencephalographic (EEG) and neurocognitive measures were simultaneously acquired to quantify alertness from 24 participants during 44-hours of sleep deprivation. Performance on a three-choice vigilance task (3C-VT), paired-associate learning/memory task (PAL) and modified Maintenance of Wakefulness Test (MWT), and sleep technician-observed drowsiness (eye-closures, head-nods, EEG slowing) were quantified. The B-Alert system automatically classifies each second of EEG on an alertness/drowsiness continuum. B-Alert classifications were significantly correlated with technician-observations, visually scored EEG and performance measures. B-Alert classifications during 3C-VT, and technician observations and performance during the 3C-VT and PAL evidenced progressively increasing drowsiness as a result of sleep deprivation with a stabilizing effect observed at the batteries occurring between 0600 and 1100 suggesting a possible circadian effect similar to those reported in previous sleep deprivation studies. Participants were given an opportunity to take a 40-minute nap approximately 24-hours into the sleep deprivation portion of the study (i.e., 7 PM on Saturday). The nap was followed by a transient period of increased alertness. Approximately 8 hours after the nap, behavioral and physiological measures of drowsiness returned to levels prior to the nap. Cluster analysis was used to stratify individuals into three groups based on their level of impairment as a result of sleep deprivation. The combination of B-Alert and neuro-behavioral measures may identify individuals whose performance is most susceptible to sleep deprivation. These objective measures could be applied in an operational setting to provide a "biobehavioral assay" to determine vulnerability to sleep deprivation.

  4. Flight contaminant trace analyser. Phase 1: Chromatographic input system

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The development of a chromatographic column capable of resolving compounds associated with spacecraft atmospheres is presented. Consideration is given to sampling techniques, column parameters and operation, and column interface with a mass spectrometer. A capillary column coated with a mixture of polyalkylene glycols is found to provide the best selectivity for resolving multicomponent mixtures found in spacecraft atmospheres. Temperature programming and isothermal operation of the column are evaluated and it is found that temperature programming has a shorter analysis time for a given carrier gas flow rate and overall superior resolution. It is observed that hydrogen provides a 15% savings in analysis time over helium. Following the optimization of column operational parameters, a mixed phase Ucon capillary is prepared for evaluation during the column test period in which the test sample is automatically analyzed. Analysis of the multicomponent test mixture is completed within 45 minutes provided temperature programming is used. All but two of the test compounds are well resolved.

  5. Effects of operating practices on commercial driver alertness

    DOT National Transportation Integrated Search

    1999-09-01

    This report summarizes the results of a one-year effort to establish the interaction between operating practices in the trucking industry and driver performance, particularly with respect to safety and fatigue. Principal topics were: Loading and unlo...

  6. 40 CFR 280.44 - Methods of release detection for piping.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...

  7. 40 CFR 280.44 - Methods of release detection for piping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...

  8. 40 CFR 280.44 - Methods of release detection for piping.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...

  9. 40 CFR 280.44 - Methods of release detection for piping.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...

  10. 40 CFR 280.44 - Methods of release detection for piping.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...

  11. The Development of Cockpit Display and Alerting Concepts for Interval Management (IM) in a Near-Term Environment

    NASA Technical Reports Server (NTRS)

    Baxley, Brian T.; Shay, Richard F.; Swieringa, Kurt A.

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) Interval Management (IM) research team has conducted a wide spectrum of work in the recent past, ranging from development and testing of the concept, procedures, and algorithm. This document focuses on the research and evaluation of the IM pilot interfaces, cockpit displays, indications, and alerting concepts for conducting IM spacing operations. The research team incorporated knowledge of human factors research, industry standards for cockpit design, and cockpit design philosophies to develop innovative displays for conducting these spacing operations. The research team also conducted a series of human-in-the-loop (HITL) experiments with commercial pilots and air traffic controllers, in as realistic a high-density arrival operation environment as could be simulated, to evaluate the spacing guidance display features and interface requirements needed to conduct spacing operations.

  12. NAPS as an Alertness Management Strategy

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Smith, Roy M.; Miller, Donna L.; Co, Elizabeth L.; Gregory, Kevin B.; Gander, Philippa H.; Lebacqz, J. Victor

    2001-01-01

    Today, 24-hour operations are necessary to meet the demands of our society and the requirements of our industrialized global economy. These around-the-clock demands pose unique physiological challenges for the humans who remain central to safe and productive operations. Optimal alertness and performance are critical factors that are increasingly challenged by unusual, extended, or changing work/rest schedules. Technological advancements and automated systems can exacerbate the challenges faced by the human factor in these environments. Shift work, transportation demands, and continuous operations engender sleep loss and circadian disruption. Both of these physiological factors can lead to increased sleepiness, decreased performance, and a reduced margin of safety. These factors can increase vulnerability to incidents and accidents in operational settings. The consequences can have both societal effects (e.g., major destructive accidents such as Three Mile Island, Exxon Valdez, Bhopal) and personal effects (e.g., an accident driving home after a night shift).

  13. A Comparison of the Efficacy of Modafinil and Dextroamphetamine as Alertness Promoting Agents in Aviators Performing Extended Operations

    DTIC Science & Technology

    2010-12-01

    sleep management programs or the administration of hypnotics (Babkoff & Krueger, 1992). However, these countermeasures can only work in situations...K. A., Ramspott, S., Sprenger, W. D., and Gardner, S. J. 1997. The efficacy of hypnotic -induced prophylactic naps for the maintenance of alertness...despite its potential risks; or c) there are no animal reproduction studies and no adequate studies in humans. Consequently, women who were

  14. Wireless Emergency Alerts: New York City Demonstration

    DTIC Science & Technology

    2013-06-01

    CMU/SEI-2012-SR-016 | 16  Consider factors affecting continuity of operations, such as support of remote employ- ees, mobile alerting...visitors and tourists , we’ll be even safer when authorities can broadcast warnings to everyone in a geographic area regardless of where they came from or...using technology to help keep people safe. [Office of the Mayor 2011b] Mayor Bloomberg declared his intention to make this new service available to New

  15. Real-time monitoring of the human alertness level

    NASA Astrophysics Data System (ADS)

    Alvarez, Robin; del Pozo, Francisco; Hernando, Elena; Gomez, Eduardo; Jimenez, Antonio

    2003-04-01

    Many accidents are associated with a driver or machine operator's alertness level. Drowsiness often develops as a result of repetitive or monotonous tasks, uninterrupted by external stimuli. In order to enhance safety levels, it would be most desirable to monitor the individual's level of attention. In this work, changes in the power spectrum of the electroencephalographic signal (EEG) are associated with the subject's level of attention. This study reports on the initial research carried out in order to answer the following important questions: (i) Does a trend exist in the shape of the power spectrum, which will indicate the state of a subject's alertness state (drowsy, relaxed or alert)? (ii) What points on the cortex are most suitable to detect drowsiness and/or high alertness? (iii) What parameters in the power spectrum are most suitable to establish a workable alertness classification in human subjects? In this work, we answer these questions and combine power spectrum estimation and artificial neural network techniques to create a non-invasive and real - time system able to classify EEG into three levels of attention: High, Relaxed and Drowsiness. The classification is made every 10 seconds o more, a suitable time span for giving an alarm signal if the individual is with insufficient level of alertness. This time span is set by the user. The system was tested on twenty subjects. High and relaxed attention levels were measured in randomise hours of the day and drowsiness attention level was measured in the morning after one night of sleep deprivation.

  16. Discovery of an Extreme MeV Blazar with the Swift Burst Alert Telescope

    NASA Technical Reports Server (NTRS)

    Sambruna, R. M.; Markwardt, C. B.; Mushotzky, R. F.; Tueller, J.; Hartman, R.; Brandt, W. N.; Schneider, D> P.; Falcone, A.; Cucchiara, A.; hide

    2006-01-01

    The Burst Alert Telescope (BAT) onboard Swift detected bright emission from 15-195 keV from the source SWIFT J0746.3+2548 (J0746 in the following), identified with the optically-faint (R approx. 19), z=2.979 quasar SDSS J074625.87+244901.2. Here we present Swift and multiwavelength observations of this source. The X-ray emission from J0746 is variable on timescales of hours to weeks in 0.5-8 keV and of a few months in 15-195 keV, but there is no accompanying spectral variability in the 0.5-8 keV band. There is a suggestion that the BAT spectrum, initially very hard (photon index Gamma approx. 0.7), steepened to Gamma approx. 1.3 in a few months, together with a decrease of the 15-195 keV flux by a factor approx. 2. The 0.5-8 keV continuum is well described by a power law with Gamma approx. 1.3, and spectral flattening below 1 keV. The latter can be described with a column density in excess of the Galactic value with intrinsic column density Nz(sub H) approx. 10(exp 22)/sq cm , or with a flatter power law, implying a sharp (Delta(Gamma) less than or approx. 1) break across 16 keV in the quasar's rest-frame. The Spectral Energy Distribution of J0746 is double-humped, with the first component peaking at IR wavelengths and the second component at MeV energies. These properties suggest that J0746 is a a blazar with high gamma-ray luminosity and low peak energy (MeV) stretching the blazar sequence to an extreme.

  17. Review of footnotes and annotations to the 1949–2013 tables of standard atomic weights and tables of isotopic compositions of the elements (IUPAC Technical Report)

    DOE PAGES

    Coplen, Tyler B.; Holden, Norman E.

    2016-01-01

    Abstract The Commission on Isotopic Abundances and Atomic Weights uses annotations given in footnotes that are an integral part of the Tables of Standard Atomic Weights to alert users to the possibilities of quite extraordinary occurrences, as well as sources with abnormal atomic-weight values outside an otherwise acceptable range. The basic need for footnotes to the Standard Atomic Weights Table and equivalent annotations to the Table of Isotopic Compositions of the Elements arises from the necessity to provide users with information that is relevant to one or more elements, but that cannot be provided using numerical data in columns. Anymore » desire to increase additional information conveyed by annotations to these Tables is tempered by the need to preserve a compact format and a style that can alert users, who would not be inclined to consult either the last full element-by-element review or the full text of a current Standard Atomic Weights of the Elements report. Since 1989, the footnotes of the Tables of Standard Atomic Weights and the annotations in column 5 of the Table of Isotopic Compositions of the Elements have been harmonized by use of three lowercase footnotes, “g”, “m”, and “r”, that signify geologically exceptionally specimens (“g”), modified isotopic compositions in material subjected to undisclosed or inadvertent isotopic fractionation (“m”), and the range in isotopic composition of normal terrestrial material prevents more precise atomic-weight value being given (“r”). As some elements are assigned intervals for their standard atomic-weight values (applies to 12 elements since 2009), footnotes “g” and “r” are no longer needed for these elements.« less

  18. Review of footnotes and annotations to the 1949–2013 tables of standard atomic weights and tables of isotopic compositions of the elements (IUPAC Technical Report)

    USGS Publications Warehouse

    Coplen, Tyler B.; Holden, Norman E.

    2016-01-01

    The Commission on Isotopic Abundances and Atomic Weights uses annotations given in footnotes that are an integral part of the Tables of Standard Atomic Weights to alert users to the possibilities of quite extraordinary occurrences, as well as sources with abnormal atomic-weight values outside an otherwise acceptable range. The basic need for footnotes to the Standard Atomic Weights Table and equivalent annotations to the Table of Isotopic Compositions of the Elements arises from the necessity to provide users with information that is relevant to one or more elements, but that cannot be provided using numerical data in columns. Any desire to increase additional information conveyed by annotations to these Tables is tempered by the need to preserve a compact format and a style that can alert users, who would not be inclined to consult either the last full element-by-element review or the full text of a current Standard Atomic Weights of the Elements report. Since 1989, the footnotes of the Tables of Standard Atomic Weights and the annotations in column 5 of the Table of Isotopic Compositions of the Elements have been harmonized by use of three lowercase footnotes, “g”, “m”, and “r”, that signify geologically exceptionally specimens (“g”), modified isotopic compositions in material subjected to undisclosed or inadvertent isotopic fractionation (“m”), and the range in isotopic composition of normal terrestrial material prevents more precise atomic-weight value being given (“r”). As some elements are assigned intervals for their standard atomic-weight values (applies to 12 elements since 2009), footnotes “g” and “r” are no longer needed for these elements.

  19. Continuous bind-and-elute protein A capture chromatography: Optimization under process scale column constraints and comparison to batch operation.

    PubMed

    Kaltenbrunner, Oliver; Diaz, Luis; Hu, Xiaochun; Shearer, Michael

    2016-07-08

    Recently, continuous downstream processing has become a topic of discussion and analysis at conferences while no industrial applications of continuous downstream processing for biopharmaceutical manufacturing have been reported. There is significant potential to increase the productivity of a Protein A capture step by converting the operation to simulated moving bed (SMB) mode. In this mode, shorter columns are operated at higher process flow and corresponding short residence times. The ability to significantly shorten the product residence time during loading without appreciable capacity loss can dramatically increase productivity of the capture step and consequently reduce the amount of Protein A resin required in the process. Previous studies have not considered the physical limitations of how short columns can be packed and the flow rate limitations due to pressure drop of stacked columns. In this study, we are evaluating the process behavior of a continuous Protein A capture column cycling operation under the known pressure drop constraints of a compressible media. The results are compared to the same resin operated under traditional batch operating conditions. We analyze the optimum system design point for a range of feed concentrations, bed heights, and load residence times and determine achievable productivity for any feed concentration and any column bed height. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:938-948, 2016. © 2016 American Institute of Chemical Engineers.

  20. Point Positioning Service for Natural Hazard Monitoring

    NASA Astrophysics Data System (ADS)

    Bar-Sever, Y. E.

    2014-12-01

    In an effort to improve natural hazard monitoring, JPL has invested in updating and enlarging its global real-time GNSS tracking network, and has launched a unique service - real-time precise positioning for natural hazard monitoring, entitled GREAT Alert (GNSS Real-Time Earthquake and Tsunami Alert). GREAT Alert leverages the full technological and operational capability of the JPL's Global Differential GPS System [www.gdgps.net] to offer owners of real-time dual-frequency GNSS receivers: Sub-5 cm (3D RMS) real-time, absolute positioning in ITRF08, regardless of location Under 5 seconds turnaround time Full covariance information Estimates of ancillary parameters (such as troposphere) optionally provided This service enables GNSS networks operators to instantly have access to the most accurate and reliable real-time positioning solutions for their sites, and also to the hundreds of participating sites globally, assuring inter-consistency and uniformity across all solutions. Local authorities with limited technical and financial resources can now access to the best technology, and share environmental data to the benefit of the entire pacific region. We will describe the specialized precise point positioning techniques employed by the GREAT Alert service optimized for natural hazard monitoring, and in particular Earthquake monitoring. We address three fundamental aspects of these applications: 1) small and infrequent motion, 2) the availability of data at a central location, and 3) the need for refined solutions at several time scales

  1. Rapid deployable global sensing hazard alert system

    DOEpatents

    Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M

    2015-04-28

    A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.

  2. An Automated Distillation Column for the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Perkins, Douglas M.; Bruce, David A.; Gooding, Charles H.; Butler, Justin T.

    2005-01-01

    A batch distillation apparatus has been designed and built for use in the undergraduate unit operations laboratory course. The column is fully automated and is accompanied by data acquisition and control software. A mixture of 1­-propanol and 2-­propanol is separated in the column, using either a constant distillate rate or constant composition…

  3. Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.

    PubMed

    Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T

    2017-08-01

    To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  4. Monitoring alert and drowsy states by modeling EEG source nonstationarity

    NASA Astrophysics Data System (ADS)

    Hsu, Sheng-Hsiou; Jung, Tzyy-Ping

    2017-10-01

    Objective. As a human brain performs various cognitive functions within ever-changing environments, states of the brain characterized by recorded brain activities such as electroencephalogram (EEG) are inevitably nonstationary. The challenges of analyzing the nonstationary EEG signals include finding neurocognitive sources that underlie different brain states and using EEG data to quantitatively assess the state changes. Approach. This study hypothesizes that brain activities under different states, e.g. levels of alertness, can be modeled as distinct compositions of statistically independent sources using independent component analysis (ICA). This study presents a framework to quantitatively assess the EEG source nonstationarity and estimate levels of alertness. The framework was tested against EEG data collected from 10 subjects performing a sustained-attention task in a driving simulator. Main results. Empirical results illustrate that EEG signals under alert versus drowsy states, indexed by reaction speeds to driving challenges, can be characterized by distinct ICA models. By quantifying the goodness-of-fit of each ICA model to the EEG data using the model deviation index (MDI), we found that MDIs were significantly correlated with the reaction speeds (r  =  -0.390 with alertness models and r  =  0.449 with drowsiness models) and the opposite correlations indicated that the two models accounted for sources in the alert and drowsy states, respectively. Based on the observed source nonstationarity, this study also proposes an online framework using a subject-specific ICA model trained with an initial (alert) state to track the level of alertness. For classification of alert against drowsy states, the proposed online framework achieved an averaged area-under-curve of 0.745 and compared favorably with a classic power-based approach. Significance. This ICA-based framework provides a new way to study changes of brain states and can be applied to monitoring cognitive or mental states of human operators in attention-critical settings or in passive brain-computer interfaces.

  5. CAT: the INGV Tsunami Alert Center

    NASA Astrophysics Data System (ADS)

    Michelini, A.

    2014-12-01

    After the big 2004 Sumatra earthquake, the tsunami threat posed by large earthquakes occurring in the Mediterranean sea was formally taken into account by many countries around the Mediterranean basin. In the past, large earthquakes that originated significant tsunamis occurred nearly once per century (Maramai et al., 2014, Annals of Geophysics). The Intergovernmental Oceanographic Commission of UNESCO (IOC-UNESCO) received a mandate from the international community to coordinate the establishment of the ICG/NEAMTWS (http://neamtic.ioc-unesco.org) through Resolution IOC-XXIII-14. Since then, several countries (France, Turkey, Greece) have started operating as candidate Tsunami Watch Provider (cTWP) in the Mediterranean. Italy started operating as cTWP on October 1st, 2014. The Italian cTWP is formed by INGV ("Istituto Nazionale di Geofisica e Vulcanologia)", DPC ("Dipartimento di Protezione Civile") and ISPRA ("Istituto Superiore per la Protezione e la Ricerca Ambientale"). INGV is in charge of issuing the alert for potentially tsunamigenic earthquakes, ISPRA provides the sea level recordings and DPC is in charge of disseminating the alert. INGV established the tsunami alert center (CAT, "Centro di Allerta Tsunami") at the end of 2013. CAT is co-located with the INGV national seismic surveillance center operated since many years. In this work, we show the technical and personnel organization of CAT, its response to recent earthquakes, and the new procedures under development for implementation. (*) INGV-CAT WG: Amato A., Basili R., Bernardi F., Bono A., Danecek P., De Martini P.M., Govoni A., Graziani L., Lauciani V., Lomax, A., Lorito S., Maramai A., Mele F., Melini D., Molinari I., Nostro C., Piatanesi A., Pintore S., Quintiliani M., Romano F., Selva J., Selvaggi G., Sorrentino D., Tonini R.

  6. Visual feedback system to reduce errors while operating roof bolting machines

    PubMed Central

    Steiner, Lisa J.; Burgess-Limerick, Robin; Eiter, Brianna; Porter, William; Matty, Tim

    2015-01-01

    Problem Operators of roof bolting machines in underground coal mines do so in confined spaces and in very close proximity to the moving equipment. Errors in the operation of these machines can have serious consequences, and the design of the equipment interface has a critical role in reducing the probability of such errors. Methods An experiment was conducted to explore coding and directional compatibility on actual roof bolting equipment and to determine the feasibility of a visual feedback system to alert operators of critical movements and to also alert other workers in close proximity to the equipment to the pending movement of the machine. The quantitative results of the study confirmed the potential for both selection errors and direction errors to be made, particularly during training. Results Subjective data confirmed a potential benefit of providing visual feedback of the intended operations and movements of the equipment. Impact This research may influence the design of these and other similar control systems to provide evidence for the use of warning systems to improve operator situational awareness. PMID:23398703

  7. Integrating UF6 Cylinder RF Tracking With Continuous Load Cell Monitoring for Verifying Declared UF6 Feed and Withdrawal Operations Verifying Declared UF6 Feed and Withdrawal Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krichinsky, Alan M; Miller, Paul; Pickett, Chris A

    2009-01-01

    Oak Ridge National Laboratory is demonstrating the integration of UF6 cylinder tracking, using RF technology, with continuous load cell monitoring (CLCM) at mock UF6 feed and withdrawal (F&W) stations. CLCM and cylinder tracking are two of several continuous-monitoring technologies that show promise in providing integrated safeguards of F&W operations at enrichment plants. Integrating different monitoring technologies allows advanced, automated event processing to screen innocuous events thereby minimizing false alerts to independent inspectors. Traditionally, international inspectors rely on batch verification of material inputs and outputs derived from operator declarations and periodic on-site inspections at uranium enrichment plants or other nuclear processingmore » facilities. Continuously monitoring F&W activities between inspections while providing filtered alerts of significant operational events will substantially increase the amount of valuable information available to inspectors thereby promising to enhance the effectiveness of safeguards and to improve efficiency in conducting on-site inspections especially at large plants for ensuring that all operations are declared.« less

  8. Lack of utility of a decision support system to mitigate delays in admission from the operating room to the postanesthesia care unit.

    PubMed

    Ehrenfeld, Jesse M; Dexter, Franklin; Rothman, Brian S; Minton, Betty Sue; Johnson, Diane; Sandberg, Warren S; Epstein, Richard H

    2013-12-01

    When the phase I postanesthesia care unit (PACU) is at capacity, completed cases need to be held in the operating room (OR), causing a "PACU delay." Statistical methods based on historical data can optimize PACU staffing to achieve the least possible labor cost at a given service level. A decision support process to alert PACU charge nurses that the PACU is at or near maximum census might be effective in lessening the incidence of delays and reducing over-utilized OR time, but only if alerts are timely (i.e., neither too late nor too early to act upon) and the PACU slot can be cleared quickly. We evaluated the maximum potential benefit of such a system, using assumptions deliberately biased toward showing utility. We extracted 3 years of electronic PACU data from a tertiary care medical center. At this hospital, PACU admissions were limited by neither inadequate PACU staffing nor insufficient PACU beds. We developed a model decision support system that simulated alerts to the PACU charge nurse. PACU census levels were reconstructed from the data at a 1-minute level of resolution and used to evaluate if subsequent delays would have been prevented by such alerts. The model assumed there was always a patient ready for discharge and an available hospital bed. The time from each alert until the maximum census was exceeded ("alert lead time") was determined. Alerts were judged to have utility if the alert lead time fell between various intervals from 15 or 30 minutes to 60, 75, or 90 minutes after triggering. In addition, utility for reducing over-utilized OR time was assessed using the model by determining if 2 patients arrived from 5 to 15 minutes of each other when the PACU census was at 1 patient less than the maximum census. At most, 23% of alerts arrived 30 to 60 minutes prior to the admission that resulted in the PACU exceeding the specified maximum capacity. When the notification window was extended to 15 to 90 minutes, the maximum utility was <50%. At most, 45% of alerts potentially would have resulted in reassigning the last available PACU slot to 1 OR versus another within 15 minutes of the original assignment. Despite multiple biases that favored effectiveness, the maximum potential benefit of a decision support system to mitigate PACU delays on the day on the surgery was below the 70% minimum threshold for utility of automated decision support messages, previously established via meta-analysis. Neither reduction in PACU delays nor reassigning promised PACU slots based on reducing over-utilized OR time were realized sufficiently to warrant further development of the system. Based on these results, the only evidence-based method of reducing PACU delays is to adjust PACU staffing and staff scheduling using computational algorithms to match the historical workload (e.g., as developed in 2001).

  9. Technical implementation plan for the ShakeAlert production system: an Earthquake Early Warning system for the West Coast of the United States

    USGS Publications Warehouse

    Given, Douglas D.; Cochran, Elizabeth S.; Heaton, Thomas; Hauksson, Egill; Allen, Richard; Hellweg, Peggy; Vidale, John; Bodin, Paul

    2014-01-01

    Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing such an EEW system, called ShakeAlert, for the West Coast of the United States. This document describes the technical implementation of that system, which leverages existing stations and infrastructure of the Advanced National Seismic System (ANSS) regional networks to achieve this new capability. While significant progress has been made in developing the ShakeAlert early warning system, improved robustness of each component of the system and additional testing and certification are needed for the system to be reliable enough to issue public alerts. Major components of the system include dense networks of ground motion sensors, telecommunications from those sensors to central processing systems, algorithms for event detection and alert creation, and distribution systems to alert users. Capital investment costs for a West Coast EEW system are projected to be $38.3M, with additional annual maintenance and operations totaling $16.1M—in addition to current ANSS expenditures for earthquake monitoring. An EEW system is complementary to, but does not replace, other strategies to mitigate earthquake losses. The system has limitations: false and missed alerts are possible, and the area very near to an earthquake epicenter may receive little or no warning. However, such an EEW system would save lives, reduce injuries and damage, and improve community resilience by reducing longer-term economic losses for both public and private entities.

  10. Human reliability and plant operating efficiency: Are 12-hour work schedules cause for concern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.

    1992-01-01

    Since the introduction of 12-h shifts to the US nuclear power industry only 8 yr ago, compressed workweek schedules have proliferated among operations departments at a phenomenal rate. Many plants that continue to use 8-h shifts during normal operations routinely change to scheduled 12-h shifts during refueling or maintenance outages. The most critical issue in the use of extended work shifts is whether alertness, physical stamina, or mental performance are compromised to the point of reducing safety or efficiency of nuclear power plant operation. Laboratory and field research sponsored by the National Institute of Occupational Safety and Health suggests thatmore » alertness, measured by self-ratings, and mental performance, measured by computer-based performance tests, are impaired on 12-h shifts compared with 8-h shifts. In contrast to these findings, plant operating efficiency and operator performance have been rated as improved in two field studies conducted in operating nuclear power plants (Fast Flux Test Facility, Washington and Ontario Hydro, Canada). A recent Electric Power Research Institute review of nuclear industry experience with 12-h shifts also suggests an overwhelmingly positive rating of 12-h schedules from both control room operators and management.« less

  11. Distillation Column Flooding Predictor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillationmore » columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid/vapor traffic that produce increased contact area and lead to substantial increases in separation efficiency – which translates to a 10% increase in energy efficiency on a BTU/bbl basis. The Flooding Predictor™ operates on the principle that between five to sixty minutes in advance of a flooding event, certain column variables experience an oscillation, a pre-flood pattern. The pattern recognition system of the Flooding Predictor™ utilizes the mathematical first derivative of certain column variables to identify the column’s pre-flood pattern(s). This pattern is a very brief, highly repeatable, simultaneous movement among the derivative values of certain column variables. While all column variables experience negligible random noise generated from the natural frequency of the process, subtle pre-flood patterns are revealed among sub-sets of the derivative values of column variables as the column approaches its hydraulic limit. The sub-set of column variables that comprise the pre-flood pattern is identified empirically through in a two-step process. First, 2ndpoint’s proprietary off-line analysis tool is used to mine historical data for pre-flood patterns. Second, the column is flood-tested to fine-tune the pattern recognition for commissioning. Then the Flooding Predictor™ is implemented as closed-loop advanced control strategy on the plant’s distributed control system (DCS), thus automating control of the column at its hydraulic limit.« less

  12. Using the principles of circadian physiology enhances shift schedule design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connolly, J.J.; Moore-Ede, M.C.

    1987-01-01

    Nuclear power plants must operate 24 h, 7 days a week. For the most part, shift schedules currently in use at nuclear power plants have been designed to meet operational needs without considering the biological clocks of the human operators. The development of schedules that also take circadian principles into account is a positive step that can be taken to improve plant safety by optimizing operator alertness. These schedules reduce the probability of human errors especially during backshifts. In addition, training programs that teach round-the-clock workers how to deal with the problems of shiftwork can help to optimize performance andmore » alertness. These programs teach shiftworkers the underlying causes of the sleep problems associated with shiftwork and also provide coping strategies for improving sleep and dealing with the transition between shifts. When these training programs are coupled with an improved schedule, the problems associated with working round-the-clock can be significantly reduced.« less

  13. Fatigue Countermeasures: Alertness Management in Flight Operations

    NASA Technical Reports Server (NTRS)

    Co, E. L.; Rosekind, M. R.; Johnson, J. M.; Weldon, K. J.; Smith, R. M.; Gregory, K. G.; Miller, D. L.; Gander, P. H.; Lebacqz, J. V.; Statler, Irving C. (Technical Monitor)

    1994-01-01

    Since 1980, the NASA Ames Fatigue Countermeasures Program has studied the effects and impact of fatigue on flight operations . Sleep loss and circadian disruption are two of the primary physiological factors that underlie fatigue in flight operations. The Program has developed an array of fatigue countermeasure recommendations that can be used to combat the effects of fatigue and continues to research potential new countermeasures. For example, one such strategy involved a NASA/FAA study on the effects of planned cockpit rest to improve crewmember alertness and performance. Based partly on the study results, the FAA is currently reviewing a proposed Advisory Circular for controlled rest on the flight deck. Since there is no simple answer to the issue of fatigue in aviation, an Education and Training Module has been developed to provide the industry with pertinent information on sleep, circadian rhythms, how flight operations affect these physiological factors, and recommendations for fatigue countermeasures. The Module will be updated as the Program's continued research efforts uncover new information and develop new countermeasure strategies,

  14. DAIDALUS: Detect and Avoid Alerting Logic for Unmanned Systems

    NASA Technical Reports Server (NTRS)

    Munoz, Cesar; Narkawicz, Anthony; Hagen, George; Upchurch, Jason; Dutle, Aaron; Consiglio, Maria; Chamberlain, James

    2015-01-01

    This paper presents DAIDALUS (Detect and Avoid Alerting Logic for Unmanned Systems), a reference implementation of a detect and avoid concept intended to support the integration of Unmanned Aircraft Systems into civil airspace. DAIDALUS consists of self-separation and alerting algorithms that provide situational awareness to UAS remote pilots. These algorithms have been formally specified in a mathematical notation and verified for correctness in an interactive theorem prover. The software implementation has been verified against the formal models and validated against multiple stressing cases jointly developed by the US Air Force Research Laboratory, MIT Lincoln Laboratory, and NASA. The DAIDALUS reference implementation is currently under consideration for inclusion in the appendices to the Minimum Operational Performance Standards for Unmanned Aircraft Systems presently being developed by RTCA Special Committee 228.

  15. Design and Operation of Cryogenic Distillation Research Column for Ultra-Low Background Experiments

    NASA Astrophysics Data System (ADS)

    Chiller, Christopher; Alanson Chiller, Angela; Jasinski, Benjamin; Snyder, Nathan; Mei, Dongming

    2013-04-01

    Motivated by isotopically enriched germanium (76Ge and 73Ge) for monocrystalline crystal growth for neutrinoless double-beta decay and dark matter experiments, a cryogenic distillation research column was developed. Without market availability of distillation columns in the temperature range of interest with capabilities necessary for our purposes, we designed, fabricated, tested, refined and operated a two-meter research column for purifying and separating gases in the temperature range from 100-200K. Due to interest in defining stratification, purity and throughput optimization, capillary lines were integrated at four equidistant points along the length of the column such that real-time residual gas analysis could guide the investigation. Interior gas column temperatures were monitored and controlled within 0.1oK accuracy at the top and bottom. Pressures were monitored at the top of the column to four significant figures. Subsequent impurities were measured at partial pressures below 2E-8torr. We report the performance of the column in this paper.

  16. The use of One-Dimensional Laboratory Experiments to Assess Hydraulic Processes in Wastewater Soil Absorption Systems

    NASA Astrophysics Data System (ADS)

    Huntzinger, D. N.; McCray, J. E.; Siegrist, R.; Lowe, K.; VanCuyk, S.

    2001-05-01

    Sixteen, one-dimensional column lysimeters have been developed to evaluate the influence of loading regime and infiltrative surface character on hydraulic performance in wastewater soil absorption systems. A duplicate design was utilized to evaluate two infiltrative surface conditions (gravel-free vs. gravel-laden) under four hydraulic loading regimes representative of possible field conditions. By loading the columns at rates of 25 to 200 cm/day, the 17 weeks of column operation actually reflect up to approximately 13 yrs of field operation (at 5 cm/day). Therefore, the cumulative mass throughput and infiltrative rate loss for each loading regime can be examined to determine the viability of accelerated loading as a means to compress the time scale of observation, while still producing meaningfully results for the field scale. During operation, the columns were loaded with septic tank effluent at a prescribed rate and routinely monitoring for applied effluent composition, infiltration rate, time-dependant soil water content, water volume throughput, and percolate composition. Bromide tracer tests were completed prior to system startup and at weeks 2, 6, and 17 of system operation. Hydraulic characterization of the columns is based on measurements of the hydraulic loading rate, volumetric throughput, soil water content, and bromide breakthrough curves. Incipient ponding of wastewater developed during the 1st week of operation for columns loaded at the highest hydraulic rate (loading regimes 1 and 2), and during the 3rd and 6th week of operation for loading regimes 3 and 4, respectfully. The bromide breakthrough curves exhibit later breakthrough and tailing as system life increases, indicating the development of spatially variability in hydraulic conductivity within the column and the development of a clogging zone at the infiltrative surface. Throughput is assessed for each loading regime to determine the infiltration rate loss versus days of operation. Loading regimes 1 and 2 approach a comparable long-term throughput rate less than 20 cm/day, while loading regimes 3 and 4 reach a long-term throughput rate of less than 10 cm/day. These one-dimensional columns allow for the analysis of infiltrative rate loss and hydraulic behavior as a result of infiltrative surface character and loading regime.

  17. Earthquake early Warning ShakeAlert system: West coast wide production prototype

    USGS Publications Warehouse

    Kohler, Monica D.; Cochran, Elizabeth S.; Given, Douglas; Guiwits, Stephen; Neuhauser, Doug; Hensen, Ivan; Hartog, Renate; Bodin, Paul; Kress, Victor; Thompson, Stephen; Felizardo, Claude; Brody, Jeff; Bhadha, Rayo; Schwarz, Stan

    2017-01-01

    Earthquake early warning (EEW) is an application of seismological science that can give people, as well as mechanical and electrical systems, up to tens of seconds to take protective actions before peak earthquake shaking arrives at a location. Since 2006, the U.S. Geological Survey has been working in collaboration with several partners to develop EEW for the United States. The goal is to create and operate an EEW system, called ShakeAlert, for the highest risk areas of the United States, starting with the West Coast states of California, Oregon, and Washington. In early 2016, the Production Prototype v.1.0 was established for California; then, in early 2017, v.1.2 was established for the West Coast, with earthquake notifications being distributed to a group of beta users in California, Oregon, and Washington. The new ShakeAlert Production Prototype was an outgrowth from an earlier demonstration EEW system that began sending test notifications to selected users in California in January 2012. ShakeAlert leverages the considerable physical, technical, and organizational earthquake monitoring infrastructure of the Advanced National Seismic System, a nationwide federation of cooperating seismic networks. When fully implemented, the ShakeAlert system may reduce damage and injury caused by large earthquakes, improve the nation’s resilience, and speed recovery.

  18. Validation of the CME Geomagnetic Forecast Alerts Under the COMESEP Alert System

    NASA Astrophysics Data System (ADS)

    Dumbović, Mateja; Srivastava, Nandita; Rao, Yamini K.; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano

    2017-08-01

    Under the European Union 7th Framework Programme (EU FP7) project Coronal Mass Ejections and Solar Energetic Particles (COMESEP, http://comesep.aeronomy.be), an automated space weather alert system has been developed to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. The COMESEP alert system uses the automated detection tool called Computer Aided CME Tracking (CACTus) to detect potentially threatening CMEs, a drag-based model (DBM) to predict their arrival, and a CME geoeffectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, the DBM calculates its arrival time at Earth and the CGFT calculates its geomagnetic risk level. The geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geoeffectiveness, as well as an estimate of the geomagnetic storm duration. We present the evaluation of the CME risk level forecast with the COMESEP alert system based on a study of geoeffective CMEs observed during 2014. The validation of the forecast tool is made by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of the DBM and CGFT (independent tools available at the Hvar Observatory website, http://oh.geof.unizg.hr). The results indicate that the success rate of the forecast in its current form is unacceptably low for a realistic operation system. Human intervention improves the forecast, but the false-alarm rate remains unacceptably high. We discuss these results and their implications for possible improvement of the COMESEP alert system.

  19. Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease - Guinea, 2014-2015.

    PubMed

    Lee, Christopher T; Bulterys, Marc; Martel, Lise D; Dahl, Benjamin A

    2016-03-11

    The epidemic of Ebola virus disease (Ebola) in West Africa began in Guinea in late 2013 (1), and on August 8, 2014, the World Health Organization (WHO) declared the epidemic a Public Health Emergency of International Concern (2). Guinea was declared Ebola-free on December 29, 2015, and is under a 90 day period of enhanced surveillance, following 3,351 confirmed and 453 probable cases of Ebola and 2,536 deaths (3). Passive surveillance for Ebola in Guinea has been conducted principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert numbers operated by prefecture health departments or to a national toll-free call center. The national call center additionally functions as a source of public health information by responding to questions from the public about Ebola. To evaluate the sensitivity of the two systems and compare the sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined prefecture alerts database, as well as the national call center database, with the national viral hemorrhagic fever (VHF) database; the VHF database contains records of all known confirmed Ebola cases. Among 17,309 alert calls analyzed from the national call center, 71 were linked to 1,838 confirmed Ebola cases in the VHF database, yielding a sensitivity of 3.9%. The sensitivity of the national call center was highest in the capital city of Conakry (11.4%) and lower in other prefectures. In comparison, the local alerts system had a sensitivity of 51.1%. Local public health infrastructure plays an important role in surveillance in an epidemic setting.

  20. Improving the Health Forecasting Alert System for Cold Weather and Heat-Waves In England: A Proof-of-Concept Using Temperature-Mortality Relationships

    PubMed Central

    Masato, Giacomo; Bone, Angie; Charlton-Perez, Andrew; Cavany, Sean; Neal, Robert; Dankers, Rutger; Dacre, Helen; Carmichael, Katie; Murray, Virginia

    2015-01-01

    Objectives In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office’s (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. Method The prototype health forecasting alert system introduces an “impact vs likelihood matrix” for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. Conclusions The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use. PMID:26431427

  1. Improving the Health Forecasting Alert System for Cold Weather and Heat-Waves In England: A Proof-of-Concept Using Temperature-Mortality Relationships.

    PubMed

    Masato, Giacomo; Bone, Angie; Charlton-Perez, Andrew; Cavany, Sean; Neal, Robert; Dankers, Rutger; Dacre, Helen; Carmichael, Katie; Murray, Virginia

    2015-01-01

    In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use.

  2. Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project: Advanced Collision Avoidance System for UAS (ACAS Xu) Interoperability White Paper Presentation

    NASA Technical Reports Server (NTRS)

    Fern, Lisa

    2017-01-01

    The Phase 1 DAA Minimum Operational Performance Standards (MOPS) provided requirements for two classes of DAA equipment: equipment Class 1 contains the basic DAA equipment required to assist a pilot in remaining well clear, while equipment Class 2 integrates the Traffic Alert and Collision Avoidance (TCAS) II system. Thus, the Class 1 system provides RWC functionality only, while the Class 2 system is intended to provide both RWC and Collision Avoidance (CA) functionality, in compliance with the Minimum Aviation System Performance (MASPS) for the Interoperability of Airborne Collision Avoidance Systems. The FAAs TCAS Program Office is currently developing Airborne Collision Avoidance System X (ACAS X) to support the objectives of the Federal Aviation Administrations (FAA) Next Generation Air Transportation System Program (NextGen). ACAS X has a suite of variants with a common underlying design that are intended to be optimized for their intended airframes and operations. ACAS Xu being is designed for UAS and allows for new surveillance technologies and tailored logic for platforms with different performance characteristics. In addition to Collision Avoidance (CA) alerting and guidance, ACAS Xu is being tuned to provide RWC alerting and guidance in compliance with the SC 228 DAA MOPS. With a single logic performing both RWC and CA functions, ACAS Xu will provide industry with an integrated DAA solution that addresses many of the interoperability shortcomings of Phase I systems. While the MOPS for ACAS Xu will specify an integrated DAA system, it will need to show compliance with the RWC alerting thresholds and alerting requirements defined in the DAA Phase 2 MOPS. Further, some functional components of the ACAS Xu system such as the remote pilots displayed guidance might be mostly references to the corresponding requirements in the DAA MOPS. To provide a seamless, integrated, RWC-CA system to assist the pilot in remaining well clear and avoiding collisions, several issues need to be addressed within the Phase 2 SC-228 DAA efforts. Interoperability of the RWC and CA alerting and guidance, and ensuring pilot comprehension, compliance and performance, will be a primary research area.

  3. Validating and Verifying Biomathematical Models of Human Fatigue

    NASA Technical Reports Server (NTRS)

    Martinez, Siera Brooke; Quintero, Luis Ortiz; Flynn-Evans, Erin

    2015-01-01

    Airline pilots experience acute and chronic sleep deprivation, sleep inertia, and circadian desynchrony due to the need to schedule flight operations around the clock. This sleep loss and circadian desynchrony gives rise to cognitive impairments, reduced vigilance and inconsistent performance. Several biomathematical models, based principally on patterns observed in circadian rhythms and homeostatic drive, have been developed to predict a pilots levels of fatigue or alertness. These models allow for the Federal Aviation Administration (FAA) and commercial airlines to make decisions about pilot capabilities and flight schedules. Although these models have been validated in a laboratory setting, they have not been thoroughly tested in operational environments where uncontrolled factors, such as environmental sleep disrupters, caffeine use and napping, may impact actual pilot alertness and performance. We will compare the predictions of three prominent biomathematical fatigue models (McCauley Model, Harvard Model, and the privately-sold SAFTE-FAST Model) to actual measures of alertness and performance. We collected sleep logs, movement and light recordings, psychomotor vigilance task (PVT), and urinary melatonin (a marker of circadian phase) from 44 pilots in a short-haul commercial airline over one month. We will statistically compare with the model predictions to lapses on the PVT and circadian phase. We will calculate the sensitivity and specificity of each model prediction under different scheduling conditions. Our findings will aid operational decision-makers in determining the reliability of each model under real-world scheduling situations.

  4. Humanizing Aggregated Data: Developing Personas to Prioritize User Needs for Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Burkett, E. R.; Jayanty, N. K.; Sellnow, D. D.; Given, D. D.; DeGroot, R. M.

    2016-12-01

    Methods that use storytelling to gather and synthesize data from people can be advantageous in understanding user needs and designing successful communication products. Using a multidisciplinary approach, we research and prioritize user needs for the ShakeAlert Earthquake Early Warning system (http://pubs.usgs.gov/fs/2014/3083/), drawing on best practices from social and behavioral science, risk communication, and human-centered design. We apply quantitative and qualitative human data collection methods including user surveys, interviews, journey maps, personas, and scenarios. Human-centered design methods leverage storytelling (a) in the acquisition of qualitative behavioral data (e.g. with journey mapping), (b) through goal-driven behaviors and needs that are synthesized into a persona as a composite model of the data, and (c) within context scenarios (the story plot or projected circumstances) in which the persona is placed in context to inform the design of relevant and usable products or services. ShakeAlert, operated by the USGS and partners, has transitioned into a production prototype phase in which users are permitted to begin testing pilot implementations to take protective actions in response to an earthquake alert. While a subset of responses will be automated (e.g., opening fire house doors), other applications of the technology will alert individuals by broadcast, public address, or mobile device notifications and require self-protective behavioral decisions (e.g., "Drop, Cover, and Hold On"). To better understand ShakeAlert user decisions and needs, we use human-centered design methods to synthesize aggregated behavioral data into "personas," which model the common behavioral patterns that can be used to guide plans for the ShakeAlert interface, messaging, and training. We present user data, methods, and resulting personas that will inform decisions moving forward to shape ShakeAlert messaging and training that will be most usable by alert recipients.

  5. Improving Service Management in Campus IT Operations

    ERIC Educational Resources Information Center

    Wan, Stewart H. C.; Chan, Yuk-Hee

    2008-01-01

    Purpose: This paper aims at presenting the benefits from implementing IT service management (ITSM) in an organization for managing campus-wide IT operations. In order to improve the fault correlation from business perspectives, we proposed a framework to automate network and system alerts with respect to its business service impact for proactive…

  6. Understanding and Counteracting Fatigue in Flight Crews

    NASA Technical Reports Server (NTRS)

    Mallis, Melissa; Neri, David; Rosekind, Mark; Gander, Philippa; Caldwell, John; Graeber, Curtis

    2007-01-01

    The materials included in the collection of documents describe the research of the NASA Ames Fatigue Countermeasures Group (FCG), which examines the extent to which fatigue, sleep loss, and circadian disruption affect flight-crew performance. The group was formed in 1980 in response to a Congressional request to examine a possible safety problem of uncertain magnitude due to transmeridian flying and a potential problem due to fatigue in association with various factors found in air-transport operations and was originally called the Fatigue/Jet Lag Program. The goals of the FCG are: (1) the development and evaluation of strategies for mitigating the effects of sleepiness and circadian disruption on pilot performance levels; (2) the identification and evaluation of objective approaches for the prediction of alertness changes in flight crews; and (3) the transfer and application of research results to the operational field via classes, workshops, and safety briefings. Some of the countermeasure approaches that have been identified to be scientifically valid and operationally relevant are brief naps (less than 40 min) in the cockpit seat and 7-min activity breaks, which include postural changes and ambulation. Although a video-based alertness monitor based on slow eyelid closure shows promise in other operational environments, research by the FCG has demonstrated that in its current form at the time of this reporting, it is not feasible to implement it in the cockpit. Efforts also focus on documenting the impact of untreated fatigue on various types of flight operations. For example, the FCG recently completed a major investigation into the effects of ultra-long-range flights (20 continuous hours in duration) on the alertness and performance of pilots in order to establish a baseline set of parameters against which the effectiveness of new ultra-long-range fatigue remedies can be judged.

  7. Vertebral Column Resection for Kyphoscoliosis in a Patient with Ehlers-Danlos Syndrome: An Intraoperative Neurophysiological Monitoring Alert.

    PubMed

    Jahangiri, Faisal R; Al Eissa, Sami; Sayegh, Samir; Al Helal, Fahad; Al-Sharif, Shomoukh A; Annaim, Monerah M; Muhammad, Sheryar; Aziz, Tanweer

    2016-08-31

    A 16-year-old male patient with Ehler-Danlos syndrome (EDS) and a back deformity since birth presented with severe kyphoscoliosis. The patient was neurologically intact but had respiratory and cardiac insufficiencies. A two-stage vertebral column resection (VCR) at T9-T10 with multiple level fusion with multimodality intraoperative neurophysiological monitoring (IONM) was planned.  During the first stage, pedicle screws were placed at multiple spinal levels above and below the VCR level. Upper and lower somatosensory evoked potentials (SSEP), transcranial electrical motor evoked potentials (TCeMEP), and electromyography were monitored continuously and showed no significant changes. The second stage was performed one week later. Baseline SSEP and TCeMEP responses were present in all extremities. The surgeon was informed of a sudden 70% amplitude drop in TCeMEP in the lower limbs with stable SSEP after ligating one of the left nerves/vessels fully stretching the spinal cord. The surgeon removed the ligation, and an improvement in motor responses followed. Surgery proceeded with the highest levels of caution. Later, there was a sudden loss of TCeMEP and SSEP in the lower limbs bilaterally. The correction was released, mean arterial pressure was increased, and intravenous dexamethasone was administered. The surgical correction was aborted, and the decision was made to close the site. Lower SSEP and TCeMEP responses remained absent until closing, while upper SSEP and TCeMEP responses remained stable. A wake-up test was done after closing. The patient moved his upper limbs but was unable to move his lower limbs bilaterally. The patient was sent for a magnetic resonance imaging scan while intubated and then sent to the intensive care unit. At 24 hours and 36 hours post-operation, the patient had no sensory and motor function below the T8 level. Forty-eight hours post-operation, the patient started to feel sensory stimuli at the T10 level. At one week post-operation, the patient regained sphincter functions, and at four weeks postoperatively, the patient's hip flexors started to recover. VCR in patients with EDS has a very high risk of damaging the spinal cord due to the fragile vasculature of the spinal cord. Real-time IONM is useful in the early identification of spinal cord injury in cases of this nature.

  8. Vertebral Column Resection for Kyphoscoliosis in a Patient with Ehlers-Danlos Syndrome: An Intraoperative Neurophysiological Monitoring Alert

    PubMed Central

    Al Eissa, Sami; Sayegh, Samir; Al Helal, Fahad; Al-Sharif, Shomoukh A; Annaim, Monerah M; Muhammad, Sheryar; Aziz, Tanweer

    2016-01-01

    A 16-year-old male patient with Ehler-Danlos syndrome (EDS) and a back deformity since birth presented with severe kyphoscoliosis. The patient was neurologically intact but had respiratory and cardiac insufficiencies. A two-stage vertebral column resection (VCR) at T9-T10 with multiple level fusion with multimodality intraoperative neurophysiological monitoring (IONM) was planned.  During the first stage, pedicle screws were placed at multiple spinal levels above and below the VCR level. Upper and lower somatosensory evoked potentials (SSEP), transcranial electrical motor evoked potentials (TCeMEP), and electromyography were monitored continuously and showed no significant changes. The second stage was performed one week later. Baseline SSEP and TCeMEP responses were present in all extremities. The surgeon was informed of a sudden 70% amplitude drop in TCeMEP in the lower limbs with stable SSEP after ligating one of the left nerves/vessels fully stretching the spinal cord. The surgeon removed the ligation, and an improvement in motor responses followed. Surgery proceeded with the highest levels of caution. Later, there was a sudden loss of TCeMEP and SSEP in the lower limbs bilaterally. The correction was released, mean arterial pressure was increased, and intravenous dexamethasone was administered. The surgical correction was aborted, and the decision was made to close the site. Lower SSEP and TCeMEP responses remained absent until closing, while upper SSEP and TCeMEP responses remained stable. A wake-up test was done after closing. The patient moved his upper limbs but was unable to move his lower limbs bilaterally. The patient was sent for a magnetic resonance imaging scan while intubated and then sent to the intensive care unit. At 24 hours and 36 hours post-operation, the patient had no sensory and motor function below the T8 level. Forty-eight hours post-operation, the patient started to feel sensory stimuli at the T10 level. At one week post-operation, the patient regained sphincter functions, and at four weeks postoperatively, the patient’s hip flexors started to recover. VCR in patients with EDS has a very high risk of damaging the spinal cord due to the fragile vasculature of the spinal cord. Real-time IONM is useful in the early identification of spinal cord injury in cases of this nature.  PMID:27766191

  9. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    During the third quarter of operation of the Aviation Safety Reporting System (ASRS), 1429 reports concerning aviation safety were received from pilots, air traffic controllers, and others in the national aviation system. Details of the administration and results of the program are discussed. The design and construction of the ASRS data base are briefly presented. Altitude deviations and potential aircraft conflicts associated with misunderstood clearances were studied and the results are discussed. Summary data regarding alert bulletins, examples of alert bulletins and responses to them, and a sample of deidentified ASRS reports are provided.

  10. Adaptive notification framework for smart nursing home.

    PubMed

    Betge-Brezetz, S; Dupont, M P; Ghorbel, M; Kamga, G B; Piekarec, S

    2009-01-01

    This paper presents an adaptive notification framework which allows to optimally deliver and handle multimedia requests and alerts in a nursing home. This framework is operated with various applications (e.g., health alert, medicine reminder, and activity proposition) and has been evaluated with different real end-users (elderly resident and medical staff) in a pilot site. Results of these evaluations are presented and highlight the added value of the framework technology to enhance the quality of life of elderly people as well as the efficiency of the medical staff.

  11. Alertness management in flight operations - Strategic napping

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Gander, Philippa H.; Dinges, David F.

    1991-01-01

    Strategic napping in two different flight operation environments is considered to illustrate its application as a fatigue countermeasure. Data obtained from commercial short-haul and long-haul operations demonstrated the utility and current practices of strategic napping. A preplanned cockpit nap acted as an acute 'safety valve' for the sleep loss, circadian disruption, and fatigue that occurs in long-haul flying.

  12. Crew Factors in Flight Operations X: Alertness Management in Flight Operations

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Gander, Philippa H.; Connell, Linda J.; Co, Elizabeth L.

    1999-01-01

    In response to a 1980 congressional request, NASA Ames Research Center initiated a Fatigue/Jet Lag Program to examine fatigue, sleep loss, and circadian disruption in aviation. Research has examined fatigue in a variety of flight environments using a range of measures (from self-report to performance to physiological). In 1991, the program evolved into the Fatigue Countermeasures Program, emphasizing the development and evaluation of strategies to maintain alertness and performance in operational settings. Over the years, the Federal Aviation Administration (FAA) has become a collaborative partner in support of fatigue research and other Program activities. From the inception of the Program, a principal goal was to return the information learned from research and other Program activities to the operational community. The objectives of this Education and Training Module are to explain what has been learned about the physiological mechanisms that underlie fatigue, demonstrate the application of this information in flight operations, and offer some specific fatigue counter-measure recommendations. It is intended for all segments of the aeronautics industry, including pilots, flight attendants, managers, schedulers, safety and policy personnel, maintenance crews, and others involved in an operational environment that challenges human physiological capabilities because of fatigue, sleep loss, and circadian disruption.

  13. Incorporation of operator knowledge for improved HMDS GPR classification

    NASA Astrophysics Data System (ADS)

    Kennedy, Levi; McClelland, Jessee R.; Walters, Joshua R.

    2012-06-01

    The Husky Mine Detection System (HMDS) detects and alerts operators to potential threats observed in groundpenetrating RADAR (GPR) data. In the current system architecture, the classifiers have been trained using available data from multiple training sites. Changes in target types, clutter types, and operational conditions may result in statistical differences between the training data and the testing data for the underlying features used by the classifier, potentially resulting in an increased false alarm rate or a lower probability of detection for the system. In the current mode of operation, the automated detection system alerts the human operator when a target-like object is detected. The operator then uses data visualization software, contextual information, and human intuition to decide whether the alarm presented is an actual target or a false alarm. When the statistics of the training data and the testing data are mismatched, the automated detection system can overwhelm the analyst with an excessive number of false alarms. This is evident in the performance of and the data collected from deployed systems. This work demonstrates that analyst feedback can be successfully used to re-train a classifier to account for variable testing data statistics not originally captured in the initial training data.

  14. Crew Factors in Flight Operations X: Alertness Management in Flight Operations

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Gander, Philippa H.; Connell, Linda J.; Co, Elizabeth L.

    2001-01-01

    In response to a 1980 congressional request, NASA Ames Research Center initiated a Fatigue/Jet Lag Program to examine fatigue, sleep loss, and circadian disruption in aviation. Research has examined fatigue in a variety of flight environments using a range of measures (from self-report to performance to physiological). In 1991, the program evolved into the Fatigue Countermeasures Program, emphasizing the development and evaluation of strategies to maintain alertness and performance in operational settings. Over the years, the Federal Aviation Administration (FAA) has become a collaborative partner in support of fatigue research and other Program activities. From the inception of the Program, a principal goal was to return the information learned from research and other Program activities to the operational community. The objectives of this Education and Training Module are to explain what has been learned about the physiological mechanisms that underlie fatigue, demonstrate the application of this information in flight operations, and offer some specific fatigue countermeasure recommendations. It is intended for all segments of the aeronautics industry, including pilots, flight attendants, managers, schedulers, safety and policy personnel, maintenance crews, and others involved in an operational environment that challenges human physiological capabilities because of fatigue, sleep loss, and circadian disruption.

  15. The Advanced Linked Extended Reconnaissance & Targeting Technology Demonstration project

    NASA Astrophysics Data System (ADS)

    Edwards, Mark

    2008-04-01

    The Advanced Linked Extended Reconnaissance & Targeting (ALERT) Technology Demonstration (TD) project is addressing many operational needs of the future Canadian Army's Surveillance and Reconnaissance forces. Using the surveillance system of the Coyote reconnaissance vehicle as an experimental platform, the ALERT TD project aims to significantly enhance situational awareness by fusing multi-sensor and tactical data, developing automated processes, and integrating beyond line-of-sight sensing. The project is exploiting important advances made in computer processing capability, displays technology, digital communications, and sensor technology since the design of the original surveillance system. As the major research area within the project, concepts are discussed for displaying and fusing multi-sensor and tactical data within an Enhanced Operator Control Station (EOCS). The sensor data can originate from the Coyote's own visible-band and IR cameras, laser rangefinder, and ground-surveillance radar, as well as from beyond line-of-sight systems such as mini-UAVs and unattended ground sensors. Video-rate image processing has been developed to assist the operator to detect poorly visible targets. As a second major area of research, automatic target cueing capabilities have been added to the system. These include scene change detection, automatic target detection and aided target recognition algorithms processing both IR and visible-band images to draw the operator's attention to possible targets. The merits of incorporating scene change detection algorithms are also discussed. In the area of multi-sensor data fusion, up to Joint Defence Labs level 2 has been demonstrated. The human factors engineering aspects of the user interface in this complex environment are presented, drawing upon multiple user group sessions with military surveillance system operators. The paper concludes with Lessons Learned from the project. The ALERT system has been used in a number of C4ISR field trials, most recently at Exercise Empire Challenge in China Lake CA, and at Trial Quest in Norway. Those exercises provided further opportunities to investigate operator interactions. The paper concludes with recommendations for future work in operator interface design.

  16. Heat integrated ethanol dehydration flowsheets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutahaean, L.S.; Shen, W.H.; Brunt, V. Van

    1995-04-01

    zA theoretical evaluation of heat-integrated heterogeneous-azeotropic ethanol-water distillation flowsheets is presented. Simulations of two column flowsheets using several different hydrocarbon entrainers reveal a region of potential heat integration and substantial reduction in operating energy. In this paper, methods for comparing hydrocarbon entrainers are shown. Two aspects of entrainers are related to operating and capital costs. The binary azeotropic composition of the entrainer-ethanol mixture is related to the energy requirements of the flowsheet. A temperature difference in the azeotrophic column is related to the size of the column and overall process staging requirements. Although the hydrophobicity of an entrainer is essentialmore » for specification of staging in the dehydration column, no substantial increase in operating energy results from an entrainer that has a higher water content. Likewise, liquid-liquid equilibria between several entrainer-ethanol-water mixtures have no substantial effect on either staging or operation. Rather, increasing the alcohol content of the entrainer-ethanol azeotrope limits its recovery in the dehydration column, and increases the recycle and reflux streams. These effects both contribute to increasing the separation energy requirements and reducing the region of potential heat integration. A cost comparison with a multieffect extractive distillation flowsheet reveals that the costs are comparable; however, the extractive distillation flowsheet is more cost effective as operating costs increase.« less

  17. Improving the health forecasting alert system for cold weather and heat-waves in England: a case-study approach using temperature-mortality relationships

    NASA Astrophysics Data System (ADS)

    Masato, Giacomo; Cavany, Sean; Charlton-Perez, Andrew; Dacre, Helen; Bone, Angie; Carmicheal, Katie; Murray, Virginia; Danker, Rutger; Neal, Rob; Sarran, Christophe

    2015-04-01

    The health forecasting alert system for cold weather and heatwaves currently in use in the Cold Weather and Heatwave plans for England is based on 5 alert levels, with levels 2 and 3 dependent on a forecast or actual single temperature action trigger. Epidemiological evidence indicates that for both heat and cold, the impact on human health is gradual, with worsening impact for more extreme temperatures. The 60% risk of heat and cold forecasts used by the alerts is a rather crude probabilistic measure, which could be substantially improved thanks to the state-of-the-art forecast techniques. In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use.

  18. Determination of model parameters for zinc (II) ion biosorption onto powdered waste sludge (PWS) in a fed-batch system.

    PubMed

    Kargi, Fikret; Cikla, Sinem

    2007-12-01

    Biosorption of zinc (II) ions onto pre-treated powdered waste sludge (PWS) was investigated using a completely mixed tank operating in fed-batch mode instead of an adsorption column. Experiments with variable feed flow rate (0.05-0.5 L h(-1)), feed Zn(II) ion concentrations (37.5-275 mg L(-1)) and amount of adsorbent (1-6 g PWS) were performed using fed-batch operation at pH 5 and room temperature (20-25 degrees C). Break-through curves describing variations of aqueous (effluent) zinc ion concentrations with time were determined for different operating conditions. Percent zinc removal from the aqueous phase decreased, but the biosorbed (solid phase) zinc ion concentration increased with increasing feed flow rate and zinc concentration. A modified Bohart-Adams equation was used to determine the biosorption capacity of PWS (q'(s)) and the rate constant (K) for zinc ion biosorption. Biosorption capacity (q'(s)=57.7 g Zn kg(-1) PWS) of PWS in fed-batch operation was found to be comparable with powdered activated carbon (PAC) in column operations. However, the adsorption rate constant (K=9.17 m(3) kg(-1) h(-1)) in fed-batch operation was an order of magnitude larger than those obtained in adsorption columns because of elimination of mass transfer limitations encountered in the column operations. Therefore, a completely mixed tank operated in fed-batch mode was proven to be more advantageous as compared to adsorption columns due to better contact between the phases yielding faster adsorption rates.

  19. Effect of Non-laminar Regime on the Efficiency of a Thermal Diffusion Column. Report No. 26; INFLUENCIA DEL REGIMEN NO LAMINAR SOBRE LA EFICIENCIA DE UNA COLUMNA DE DIFUSION TERMICA. Informe No. 26

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Espanol, C.E.

    1960-01-01

    The effect of the appearance of localized perturbations on the separation factor and operation time of a thermal diffusion column is studied. The separation factor of a column was obtained experimentally and the enrichment was recorded continuously as a function of time by measurement of the thermal conductivity of the gaseous mixture at the foot and head of the column. A mixture of Ar and CO/sub 2/ was used as it behaves as an isotopic mixture. The results showed the linear decrease of the separation factor with the number of stages and the operation time practically does not vary. Themore » introduction of localized turbulences in a thermal diffusion column reduces the column yield. (J.S.R.)« less

  20. Aircraft Conflict Analysis and Real-Time Conflict Probing Using Probabilistic Trajectory Modeling

    NASA Technical Reports Server (NTRS)

    Yang, Lee C.; Kuchar, James K.

    2000-01-01

    Methods for maintaining separation between aircraft in the current airspace system have been built from a foundation of structured routes and evolved procedures. However, as the airspace becomes more congested and the chance of failures or operational error become more problematic, automated conflict alerting systems have been proposed to help provide decision support and to serve as traffic monitoring aids. The problem of conflict detection and resolution has been tackled from a number of different ways, but in this thesis, it is recast as a problem of prediction in the presence of uncertainties. Much of the focus is concentrated on the errors and uncertainties from the working trajectory model used to estimate future aircraft positions. The more accurate the prediction, the more likely an ideal (no false alarms, no missed detections) alerting system can be designed. Additional insights into the problem were brought forth by a review of current operational and developmental approaches found in the literature. An iterative, trial and error approach to threshold design was identified. When examined from a probabilistic perspective, the threshold parameters were found to be a surrogate to probabilistic performance measures. To overcome the limitations in the current iterative design method, a new direct approach is presented where the performance measures are directly computed and used to perform the alerting decisions. The methodology is shown to handle complex encounter situations (3-D, multi-aircraft, multi-intent, with uncertainties) with relative ease. Utilizing a Monte Carlo approach, a method was devised to perform the probabilistic computations in near realtime. Not only does this greatly increase the method's potential as an analytical tool, but it also opens up the possibility for use as a real-time conflict alerting probe. A prototype alerting logic was developed and has been utilized in several NASA Ames Research Center experimental studies.

  1. Chemical Safety Alert: Rupture Hazard of Pressure Vessels

    EPA Pesticide Factsheets

    Pressure vessels or boilers can fail catastrophically if they are not properly designed, constructed, operated, inspected, tested, or repaired. Risk increases if vessels contents are toxic, corrosive, reactive, or flammable.

  2. Hazards in Motion: Development of Mobile Geofences for Use in Logging Safety

    PubMed Central

    Zimbelman, Eloise G.; Keefe, Robert F.; Strand, Eva K.; Kolden, Crystal A.; Wempe, Ann M.

    2017-01-01

    Logging is one of the most hazardous occupations in the United States. Real-time positioning that uses global navigation satellite system (GNSS) technology paired with radio frequency transmission (GNSS-RF) has the potential to reduce fatal and non-fatal accidents on logging operations through the use of geofences that define safe work areas. Until recently, most geofences have been static boundaries. The aim of this study was to evaluate factors affecting mobile geofence accuracy in order to determine whether virtual safety zones around moving ground workers or equipment are a viable option for improving situational awareness on active timber sales. We evaluated the effects of walking pace, transmission interval, geofence radius, and intersection angle on geofence alert delay using a replicated field experiment. Simulation was then used to validate field results and calculate the proportion of GNSS error bearings resulting in early alerts. The interaction of geofence radius and intersection angle affected safety geofence alert delay in the field experiment. The most inaccurate alerts were negative, representing early warning. The magnitude of this effect was largest at the greatest intersection angles. Simulation analysis supported these field results and also showed that larger GNSS error corresponded to greater variability in alert delay. Increasing intersection angle resulted in a larger proportion of directional GNSS error that triggered incorrect, early warnings. Because the accuracy of geofence alerts varied greatly depending on GNSS error and angle of approach, geofencing for occupational safety is most appropriate for general situational awareness unless real-time correction methods to improve accuracy or higher quality GNSS-RF transponders are used. PMID:28394303

  3. Cryogenic distillation facility for isotopic purification of protium and deuterium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alekseev, I.; Arkhipov, Ev.; Bondarenko, S.

    Isotopic purification of the protium and deuterium is an important requirement of many physics experiments. A cryogenic facility for high-efficiency separation of hydrogen isotopes with a cryogenic distillation column as the main element is described. The instrument is portable, so that it can be used at the experimental site. It was designed and built at the Petersburg Nuclear Physics Institute, Gatchina, Russia. Fundamental operating parameters have been measured including a liquid holdup in the column packing, the pressure drops across the column and the purity of the product at different operating modes. A mathematical model describes expected profiles of hydrogenmore » isotope concentration along the distillation column. An analysis of ortho-parahydrogen isomeric composition by gas chromatography was used for evaluation of the column performance during the tuning operations. The protium content during deuterium purification (≤100 ppb) was measured using gas chromatography with accumulation of the protium in the distillation column. A high precision isotopic measurement at the Institute of Particle Physics, ETH-Zurich, Switzerland, provided an upper bound of the deuterium content in protium (≤6 ppb), which exceeds all commercially available products.« less

  4. 40 CFR 63.1439 - General recordkeeping and reporting provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for 6 hours, then the daily average is the average of the temperature measurements taken during those... operating conditions, considering typical variability of the specific process and combustion, recovery, or... temperature reading of −200 °C on a boiler), and will alert the operator by alarm or other means. The owner or...

  5. Alert Notification System Router

    NASA Technical Reports Server (NTRS)

    Gurganus, Joseph; Carey, Everett; Antonucci, Robert; Hitchener, Peter

    2009-01-01

    The Alert Notification System Router (ANSR) software provides satellite operators with notifications of key events through pagers, cell phones, and e-mail. Written in Java, this application is specifically designed to meet the mission-critical standards for mission operations while operating on a variety of hardware environments. ANSR is a software component that runs inside the Mission Operations Center (MOC). It connects to the mission's message bus using the GMSEC [Goddard Space Flight Center (GSFC) Mission Services Evolution Center (GMSEC)] standard. Other components, such as automation and monitoring components, can use ANSR to send directives to notify users or groups. The ANSR system, in addition to notifying users, can check for message acknowledgements from a user and escalate the notification to another user if there is no acknowledgement. When a firewall prevents ANSR from accessing the Internet directly, proxies can be run on the other side of the wall. These proxies can be configured to access the Internet, notify users, and poll for their responses. Multiple ANSRs can be run in parallel, providing a seamless failover capability in the event that one ANSR system becomes incapacitated.

  6. Effect of Traffic Position Accuracy for Conducting Safe Airport Surface Operations

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III; Bailey, Randall E.; Arthur, Jarvis J., III; Barnes, James R.

    2014-01-01

    The Next Generation Air Transportation System (NextGen) concept proposes many revolutionary operational concepts and technologies, such as display of traffic information and movements, airport moving maps (AMM), and proactive alerts of runway incursions and surface traffic conflicts, to deliver an overall increase in system capacity and safety. A piloted simulation study was conducted at the National Aeronautics and Space Administration (NASA) Langley Research Center to evaluate the ability to conduct safe and efficient airport surface operations while utilizing an AMM displaying traffic of various position accuracies as well as the effect of traffic position accuracy on airport conflict detection and resolution (CD&R) capability. Nominal scenarios and off-nominal conflict scenarios were conducted using 12 airline crews operating in a simulated Memphis International Airport terminal environment. The data suggest that all traffic should be shown on the airport moving map, whether qualified or unqualified, and conflict detection and resolution technologies provide significant safety benefits. Despite the presence of traffic information on the map, collisions or near collisions still occurred; when indications or alerts were generated in these same scenarios, the incidences were averted.

  7. Mission Assurance, Threat Alert, Disaster Resiliency and Response (MATADRR) Product Reference Guide

    DTIC Science & Technology

    2014-06-01

    communication systems customized for military , government, healthcare, higher education and commercial organizations. The AtHoc solutions automate the end...how to develop an integrated operational picture across the local, state and military environment where they operate. Considerations such as the...services are used to support sound decision making in disaster response and civil- military humanitarian assistance operations, as well as in disaster

  8. NASA's Internal Space Weather Working Group

    NASA Technical Reports Server (NTRS)

    St. Cyr, O. C.; Guhathakurta, M.; Bell, H.; Niemeyer, L.; Allen, J.

    2011-01-01

    Measurements from many of NASA's scientific spacecraft are used routinely by space weather forecasters, both in the U.S. and internationally. ACE, SOHO (an ESA/NASA collaboration), STEREO, and SDO provide images and in situ measurements that are assimilated into models and cited in alerts and warnings. A number of years ago, the Space Weather laboratory was established at NASA-Goddard, along with the Community Coordinated Modeling Center. Within that organization, a space weather service center has begun issuing alerts for NASA's operational users. NASA's operational user community includes flight operations for human and robotic explorers; atmospheric drag concerns for low-Earth orbit; interplanetary navigation and communication; and the fleet of unmanned aerial vehicles, high altitude aircraft, and launch vehicles. Over the past three years we have identified internal stakeholders within NASA and formed a Working Group to better coordinate their expertise and their needs. In this presentation we will describe this activity and some of the challenges in forming a diverse working group.

  9. Inhibitory effects of acidic pH and confounding effects of moisture content on methane biofiltration.

    PubMed

    Barzgar, Sonya; Hettiaratchi, Joseph Patrick; Pearse, Lauretta; Kumar, Sunil

    2017-12-01

    This study focussed on evaluating the effect of hydrogen sulfide (H 2 S) on biological oxidation of waste methane (CH 4 ) gas in compost biofilters, Batch experiments were conducted to determine the dependency of maximum methane oxidation rate (V max ) on two main factors; pH and moisture content, as well as their interaction effects. The maximum V max was observed at a pH of 7.2 with decreasing V max values observed with decreasing pH, irrespective of moisture content. Flow-through columns operated at a pH of 4.5 oxidized CH 4 at a flux rate of 53g/m 2 /d compared to 146g/m 2 /d in columns operated at neutral pH. No oxidation activity was observed for columns operated at pH 2.5, and DNA sequencing analysis of samples led to the conclusion that highly acidic conditions were responsible for inhibiting the ability of methanotrophs to oxidize CH 4 . Biofilter columns operated at pH 2.5 contained only 2% methanotrophs (type I) out of the total microbial population, compared to 55% in columns operated at pH 7.5. Overall, changes in the population of methanotrophs with acidification within the biofilters compromised its capacity to oxidize CH 4 which demonstrated that a compost biofilter could not operate efficiently in the presence of high levels of H 2 S. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Centralized Alert-Processing and Asset Planning for Sensorwebs

    NASA Technical Reports Server (NTRS)

    Castano, Rebecca; Chien, Steve A.; Rabideau, Gregg R.; Tang, Benyang

    2010-01-01

    A software program provides a Sensorweb architecture for alert-processing, event detection, asset allocation and planning, and visualization. It automatically tasks and re-tasks various types of assets such as satellites and robotic vehicles in response to alerts (fire, weather) extracted from various data sources, including low-level Webcam data. JPL has adapted cons iderable Sensorweb infrastructure that had been previously applied to NASA Earth Science applications. This NASA Earth Science Sensorweb has been in operational use since 2003, and has proven reliability of the Sensorweb technologies for robust event detection and autonomous response using space and ground assets. Unique features of the software include flexibility to a range of detection and tasking methods including those that require aggregation of data over spatial and temporal ranges, generality of the response structure to represent and implement a range of response campaigns, and the ability to respond rapidly.

  11. Pilot Preferences for Information Provided and Its Format for Status, Alerts, and Controls

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    2004-01-01

    With the increased use of cathode ray tubes (CRTs) in flight decks and the computing power available, it is possible to combine status screens, alerts/procedures screens, and control screens onto a single display. This report presents the results of a survey designed to assess the perceived helpfulness and need of various pieces of information that could be included on status and control screens. The results from the survey indicate that operators want parameter ranges that change depending on the current aircraft configuration shown on bow-tie or dial displays. These displays should show the current value, normal range, alert type and range, and predictive information. Respondents wanted to see system relationships to one another for both component control and menu selection. When bringing up these various displays, this information should come up with a single button push. Finally, checklists should sense when a component has changed to the desired state.

  12. Piezoelectric Vibrational and Acoustic Alert for a Personal Communication Device

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E. (Inventor); Hellbaum, Richard F. (Inventor); Daugherty, Robert H. (Inventor); Scholz, Raymond C. (Inventor); Little, Bruce D. (Inventor); Fox, Robert L. (Inventor); Denhardt, Gerald A. (Inventor); Jang, SeGon (Inventor); Balein, Rizza (Inventor)

    2001-01-01

    An alert apparatus for a personal communication device includes a mechanically prestressed piezoelectric wafer positioned within the personal communication device and an alternating voltage input line coupled at two points of the wafer where polarity is recognized. The alert apparatus also includes a variable frequency device coupled to the alternating voltage input line, operative to switch the alternating voltage on the alternating voltage input line at least between an alternating voltage having a first frequency and an alternating voltage having a second frequency. The first frequency is preferably sufficiently high so as to cause the wafer to vibrate at a resulting frequency that produces a sound perceptible by a human ear, and the second frequency is preferably sufficiently low so as to cause the wafer to vibrate at a resulting frequency that produces a vibration readily felt by a holder of the personal communication device.

  13. Temporal Precedence Checking for Switched Models and its Application to a Parallel Landing Protocol

    NASA Technical Reports Server (NTRS)

    Duggirala, Parasara Sridhar; Wang, Le; Mitra, Sayan; Viswanathan, Mahesh; Munoz, Cesar A.

    2014-01-01

    This paper presents an algorithm for checking temporal precedence properties of nonlinear switched systems. This class of properties subsume bounded safety and capture requirements about visiting a sequence of predicates within given time intervals. The algorithm handles nonlinear predicates that arise from dynamics-based predictions used in alerting protocols for state-of-the-art transportation systems. It is sound and complete for nonlinear switch systems that robustly satisfy the given property. The algorithm is implemented in the Compare Execute Check Engine (C2E2) using validated simulations. As a case study, a simplified model of an alerting system for closely spaced parallel runways is considered. The proposed approach is applied to this model to check safety properties of the alerting logic for different operating conditions such as initial velocities, bank angles, aircraft longitudinal separation, and runway separation.

  14. Autonomous Sensorweb Operations for Integrated Space, In-Situ Monitoring of Volcanic Activity

    NASA Technical Reports Server (NTRS)

    Chien, Steve A.; Doubleday, Joshua; Kedar, Sharon; Davies, Ashley G.; Lahusen, Richard; Song, Wenzhan; Shirazi, Behrooz; Mandl, Daniel; Frye, Stuart

    2010-01-01

    We have deployed and demonstrated operations of an integrated space in-situ sensorweb for monitoring volcanic activity. This sensorweb includes a network of ground sensors deployed to the Mount Saint Helens volcano as well as the Earth Observing One spacecraft. The ground operations and space operations are interlinked in that ground-based intelligent event detections can cause the space segment to acquire additional data via observation requests and space-based data acquisitions (thermal imagery) can trigger reconfigurations of the ground network to allocate increased bandwidth to areas of the network best situated to observe the activity. The space-based operations are enabled by an automated mission planning and tasking capability which utilizes several Opengeospatial Consortium (OGC) Sensorweb Enablement (SWE) standards which enable acquiring data, alerts, and tasking using web services. The ground-based segment also supports similar protocols to enable seamless tasking and data delivery. The space-based segment also supports onboard development of data products (thermal summary images indicating areas of activity, quicklook context images, and thermal activity alerts). These onboard developed products have reduced data volume (compared to the complete images) which enables them to be transmitted to the ground more rapidly in engineering channels.

  15. Pixel color feature enhancement for road signs detection

    NASA Astrophysics Data System (ADS)

    Zhang, Qieshi; Kamata, Sei-ichiro

    2010-02-01

    Road signs play an important role in our daily life which used to guide drivers to notice variety of road conditions and cautions. They provide important visual information that can help drivers operating their vehicles in a manner for enhancing traffic safety. The occurrence of some accidents can be reduced by using automatic road signs recognition system which can alert the drivers. This research attempts to develop a warning system to alert the drivers to notice the important road signs early enough to refrain road accidents from happening. For solving this, a non-linear weighted color enhancement method by pixels is presented. Due to the advantage of proposed method, different road signs can be detected from videos effectively. With suitably coefficients and operations, the experimental results have proved that the proposed method is robust, accurate and powerful in road signs detection.

  16. Use of emulsified vegetable oil to support bioremediation of TCE DNAPL in soil columns.

    PubMed

    Harkness, Mark; Fisher, Angela

    2013-08-01

    The interaction between emulsified vegetable oil (EVO) and trichloroethylene (TCE) dense non-aqueous phase liquid (DNAPL) was observed using two soil columns and subsequent reductive dechlorination of TCE was monitored over a three year period. Dyed TCE DNAPL (~75 g) was emplaced in one column (DNAPL column), while the second was DNAPL-free (plume column). EVO was added to both columns and partitioning of the EVO into the TCE DNAPL was measured and quantified. TCE (1.9 mM) was added to the influent of the plume column to simulate conditions down gradient of a DNAPL source area and the columns were operated independently for more than one year, after which they were connected in series. Initially limited dechlorination of TCE to cDCE was observed in the DNAPL column, while the plume column supported complete reductive dechlorination of TCE to ethene. Upon connection and reamendment of the plume column with EVO, near saturation levels of TCE from the effluent of the DNAPL column were rapidly dechlorinated to c-DCE and VC in the plume column; however, this high rate dechlorination produced hydrochloric acid which overwhelmed the buffering capacity of the system and caused the pH to drop below 6.0. Dechlorination efficiency in the columns subsequently deteriorated, as measured by the chloride production and Dehalococcoides counts, but was restored by adding sodium bicarbonate buffer to the influent groundwater. Robust dechlorination was eventually observed in the DNAPL column, such that the TCE DNAPL was largely removed by the end of the study. Partitioning of the EVO into the DNAPL provided significant operational benefits to the remediation system both in terms of electron donor placement and longevity. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Novel online monitoring and alert system for anaerobic digestion reactors.

    PubMed

    Dong, Fang; Zhao, Quan-Bao; Li, Wen-Wei; Sheng, Guo-Ping; Zhao, Jin-Bao; Tang, Yong; Yu, Han-Qing; Kubota, Kengo; Li, Yu-You; Harada, Hideki

    2011-10-15

    Effective monitoring and diagnosis of anaerobic digestion processes is a great challenge for anaerobic digestion reactors, which limits their stable operation. In this work, an online monitoring and alert system for upflow anaerobic sludge blanket (UASB) reactors is developed on the basis of a set of novel evaluating indexes. The two indexes, i.e., stability index S and auxiliary index a, which incorporate both gas- and liquid-phase parameters for UASB, enable a quantitative and comprehensive evaluation of reactor status. A series of shock tests is conducted to evaluate the response of the monitoring and alert system to organic overloading, hydraulic, temperature, and toxicant shocks. The results show that this system enables an accurate and rapid monitoring and diagnosis of the reactor status, and offers reliable early warnings on the potential risks. As the core of this system, the evaluating indexes are demonstrated to be of high accuracy and sensitivity in process evaluation and good adaptability to the artificial intelligence and automated control apparatus. This online monitoring and alert system presents a valuable effort to promote the automated monitoring and control of anaerobic digestion process, and holds a high promise for application.

  18. Alert-QSAR. Implications for Electrophilic Theory of Chemical Carcinogenesis

    PubMed Central

    Putz, Mihai V.; Ionaşcu, Cosmin; Putz, Ana-Maria; Ostafe, Vasile

    2011-01-01

    Given the modeling and predictive abilities of quantitative structure activity relationships (QSARs) for genotoxic carcinogens or mutagens that directly affect DNA, the present research investigates structural alert (SA) intermediate-predicted correlations ASA of electrophilic molecular structures with observed carcinogenic potencies in rats (observed activity, A = Log[1/TD50], i.e., ASA=f(X1SA,X2SA,…)). The present method includes calculation of the recently developed residual correlation of the structural alert models, i.e., ARASA=f(A−ASA,X1SA,X2SA,…). We propose a specific electrophilic ligand-receptor mechanism that combines electronegativity with chemical hardness-associated frontier principles, equality of ligand-reagent electronegativities and ligand maximum chemical hardness for highly diverse toxic molecules against specific receptors in rats. The observed carcinogenic activity is influenced by the induced SA-mutagenic intermediate effect, alongside Hansch indices such as hydrophobicity (LogP), polarizability (POL) and total energy (Etot), which account for molecular membrane diffusion, ionic deformation, and stericity, respectively. A possible QSAR mechanistic interpretation of mutagenicity as the first step in genotoxic carcinogenesis development is discussed using the structural alert chemoinformation and in full accordance with the Organization for Economic Co-operation and Development QSAR guidance principles. PMID:21954348

  19. The First Ground-Level Enhancement of Solar Cycle 24 on 17 May 2012 and Its Real-Time Detection

    NASA Astrophysics Data System (ADS)

    Papaioannou, A.; Souvatzoglou, G.; Paschalis, P.; Gerontidou, M.; Mavromichalaki, H.

    2014-01-01

    Ground-level enhancements (GLEs) are defined as sudden increases in the recorded intensity of cosmic-ray particles, usually by neutron monitors (NMs). In this work we present a time-shifting analysis (TSA) for the first arriving particles that were detected at Earth by NMs. We also present an automated real-time GLE alert that has been developed and is operating via the Neutron Monitor Database (NMDB), which successfully identified the 17 May 2012 event, designated as GLE71. We discuss the time evolution of the real-time GLE alert that was issued for GLE71 and present the event onset-time for NMs that contributed to this GLE alert based on their archived data. A comparison with their real-time time-stamp was made to illustrate the necessity for high-resolution data ( e.g. 1-min time resolution) made available at every minute. The first results on the propagation of relativistic protons that have been recorded by NMs, as inferred by the TSA, imply that they are most probably accelerated by the coronal-mass-ejection-driven shock. Furthermore, the successful usage of NM data and the corresponding achievement of issuing a timely GLE alert are discussed.

  20. Avoid problems during distillation column startups

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sloley, A.W.

    1996-07-01

    The startup of a distillation column is the end product of the design process. Indeed, startup is the culmination of the theory and practice of designing the column to meet the process objectives. The author will direct most of this discussion towards column revamps due to their inherent complexity; however, the points apply equally to new columns, as well. The most important question that must be answered prior to a startup is how will the distillation system changes affect initial startup, process control of the system, and normal day-to-day operations? How will the operators run the system? Steady-state distillation-column simulationsmore » alone cannot provide an authoritative answer and, indeed, engineers` over-reliance on software too often has led them to ignore many practical aspects. Computer modeling, while an important engineering tool, is not reality. Distillation columns are real functioning pieces of equipment that require practical skills to successfully modify. They are not steady-state solutions that result from converged computer simulations. Early planning, coupled with thorough inspections and comprehensive reviews of instrumentation and procedures, can play a key role in assuring smooth startups.« less

  1. Mexican Seismic Alert System's SAS-I algorithm review considering strong earthquakes felt in Mexico City since 1985

    NASA Astrophysics Data System (ADS)

    Cuellar Martinez, A.; Espinosa Aranda, J.; Suarez, G.; Ibarrola Alvarez, G.; Ramos Perez, S.; Camarillo Barranco, L.

    2013-05-01

    The Seismic Alert System of Mexico (SASMEX) uses three algorithms for alert activation that involve the distance between the seismic sensing field station (FS) and the city to be alerted; and the forecast for earthquake early warning activation in the cities integrated to the system, for example in Mexico City, the earthquakes occurred with the highest accelerations, were originated in the Pacific Ocean coast, whose distance this seismic region and the city, favors the use of algorithm called Algorithm SAS-I. This algorithm, without significant changes since its beginning in 1991, employs the data that generate one or more FS during P wave detection until S wave detection plus a period equal to the time employed to detect these phases; that is the double S-P time, called 2*(S-P). In this interval, the algorithm performs an integration process of quadratic samples from FS which uses a triaxial accelerometer to get two parameters: amplitude and growth rate measured until 2*(S-P) time. The parameters in SAS-I are used in a Magnitude classifier model, which was made from Guerrero Coast earthquakes time series, with reference to Mb magnitude mainly. This algorithm activates a Public or Preventive Alert if the model predicts whether Strong or Moderate earthquake. The SAS-I algorithm has been operating for over 23 years in the subduction zone of the Pacific Coast of Mexico, initially in Guerrero and followed by Oaxaca; and since March 2012 in the seismic region of Pacific covering the coasts among Jalisco, Colima, Michoacan, Guerrero and Oaxaca, where this algorithm has issued 16 Public Alert and 62 Preventive Alerts to the Mexico City where its soil conditions increase damages by earthquake such as the occurred in September 1985. This work shows the review of the SAS-I algorithm and possible alerts that it could generate from major earthquakes recordings detected by FS or seismometers near the earthquakes, coming from Pacific Ocean Coast whose have been felt in Mexico City, in order to observe the performance SAS-I algorithm.

  2. ShakeAlert Users Transition to the Production Prototype System

    NASA Astrophysics Data System (ADS)

    Strauss, J. A.; Vinci, M.; Steele, W. P.; Hellweg, M.; Allen, R. M.; DeGroot, R. M.

    2016-12-01

    The ShakeAlert Earthquake Early Warning system transitioned from the demonstration system into the fully-fledged production prototype system this year. Users were migrated over to the new system concurrent with the release of the ShakeAlert UserDisplay Version 2.5.0. The production prototype system provides robust connectivity, fail-over mechanisms to ensure that alarms are deliverd even if one connection fails, and provides a framework to connect future stations, participants, and other sources as the project expands to the full public system. We will present an overview of key user sectors that are either testing or launching pilot projects for the system within their organizations. We will outline the implementation of certain actions, and highlight accomplishments and challenges the Beta Users encounter in fully implementing ShakeAlert within their organizations. By better studying these issues, project partners can better assist the users in incorporating early warning in their operations. Opening up the system to allow for pilot projects enables ShakeAlert users to develop hardware, software, and policy solutions for actions in response to early warning alerts in a controlled environment. This is the first step on the path toward limited rollouts. The pilot groups leverage the expertise of our stakeholders to develop the `last mile' alert distribution and responses. The transition went smoothly in February 2015, for users in California, and we expect to connect with more beta users and pilot groups in this next phase. User transition is planned for Fall 2016 for users in the Pacific Northwest. Beta Users, such as municipalities, emergency response groups, and county officials, lifelines, schools, and private industry continue to meet with ShakeAlert partners to 1) further education and training on both benefits and limitations 2) strategize on implementation actions, such as opening fire house bay doors in response to an alarm, and 3) coordinate continued engagement as the system comes online with more Users and in more areas. The newly created Joint Committee on Communication, Education, and Outreach is aiding with the education and training aspect of the rollout.

  3. Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department

    PubMed Central

    Balamuth, Fran; Alpern, Elizabeth R.; Grundmeier, Robert W.; Chilutti, Marianne; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing

    2015-01-01

    Objectives To compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). Methods This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Results Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159, and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% CI = 72.1% to 73.4%) and specificity 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity 92.1% (95% CI = 91.7% to 92.4%), and specificity 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment vs. algorithmic alert were 40.3% vs. 2.5% and 99.88 % vs. 99.96%, respectively. Conclusions The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. PMID:26474032

  4. Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department.

    PubMed

    Balamuth, Fran; Alpern, Elizabeth R; Grundmeier, Robert W; Chilutti, Marianne; Weiss, Scott L; Fitzgerald, Julie C; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing

    2015-11-01

    The objective was to compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159 and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% confidence interval [CI] = 72.1% to 73.4%) and specificity of 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity of 92.1% (95% CI = 91.7% to 92.4%) and specificity of 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment versus algorithmic alert were 40.3% versus 2.5% and 99.88% versus 99.96%, respectively. The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. © 2015 by the Society for Academic Emergency Medicine.

  5. The Systems Engineering Design of a Smart Forward Operating Base Surveillance System for Forward Operating Base Protection

    DTIC Science & Technology

    2013-06-01

    fixed sensors located along the perimeter of the FOB. The video is analyzed for facial recognition to alert the Network Operations Center (NOC...the UAV is processed on board for facial recognition and video for behavior analysis is sent directly to the Network Operations Center (NOC). Video...captured by the fixed sensors are sent directly to the NOC for facial recognition and behavior analysis processing. The multi- directional signal

  6. An Analysis of the Navy Regional Data Automation Center (NARDAC) chargeback System

    DTIC Science & Technology

    1986-09-01

    addition, operational control is concerned with performing predefined activities whereas management control relates to the organiza- tion’s goals and...In effect, the management control system monitors the progress of operations and alerts the "appropriate management level" when performance as measured...architecture, the financial control processes, and the audit function ( Brandon , 1978; Anderson, 1983). In an operating DP environment, however, non-financial

  7. Awareness Enhancing and Monitoring Device plus Habit Reversal in the Treatment of Trichotillomania: An Open Feasibility Trial.

    PubMed

    Himle, Joseph A; Bybee, Deborah; O'Donnell, Lisa A; Weaver, Addie; Vlnka, Sarah; DeSena, Daniel T; Rimer, Jessica M

    2018-01-01

    Habit Reversal Therapy (HRT) is helpful for many persons suffering from trichotillomania. However successful habit reversal therapy requires awareness of hair pulling behaviors. Available methods to monitor hair pulling behaviors are less than ideal, particularly when sufferers are unaware of their pulling-related behaviors. This open feasibility trial included 20 persons with trichotillomania who were treated with nine weeks of HRT with experienced clinicians following a well-established HRT protocol. HRT was augmented with an electronic Awareness Enhancing and Monitoring Device (AEMD) designed to alert users of hand to head contact and to monitor the frequency of pulling-related behaviors. The AEMD included a neck unit and two wrist units, each equipped with vibrating alert functions. The results of the open trial revealed significant improvements in trichotillomania symptoms as measured by clinician and self-report rating scales. Most participants met study criteria for HRT completion and treatment effects were large. Participants reported that the AEMD, when operational, was effective in alerting participants to TTM-related behaviors. The monitoring function of the AEMD did not operate as designed. Subjective feedback focused on the AEMD concept was positive but AEMD reliability problems and complaints about the wearability the units were common. Recommendations for AEMD design modifications were included.

  8. DANTi: Detect and Avoid iN The Cockpit

    NASA Technical Reports Server (NTRS)

    Chamberlain, James; Consiglio, Maria; Munoz, Cesar

    2017-01-01

    Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.

  9. FT4 Data Analysis Summary (SSI-ARC)

    NASA Technical Reports Server (NTRS)

    Isaacson, Douglas R.; Gong, Chester; Reardon, Scott Edward; Santiago, Confesor

    2016-01-01

    Standards for Unmanned Aircraft System (UAS) Detect-and-Avoid (DAA) systems are currently being developed under the auspices of the RTCA Special Committee 228 (SC-228). To support the development of these standards, a series of flight tests has been conducted at NASAs Armstrong Flight Research Center (NASA-AFRC). The fourth in this series of flight test activities (Flight Test 4, or simply FT4) was conducted during the Spring and Summer of 2016. FT4 supported the objectives of numerous organizations working toward UAS DAA Minimum Operational Performance Standards (MOPS) and UAS DAA Radar MOPS. The summary provided herein is limited to the objectives, analysis and conclusions of the NASA Ames Research Center (NASA-ARC) SSI team toward the refinement of UAS DAA MOPS. This document provides a high-level overview of FT4 and the SSI-ARC objectives, a summary of the data analysis methodology and recommendations for UAS DAA MOPS refinements based on the data analysis results. A total of 72 encounters were flown to support SSI-ARC objectives. Test results were generally consistent with acceptable UAS DAA system performance and will be considered in broader SC-228 requirements validation efforts. Observed alert lead times indicated acceptable UAS DAA alerting performance. Effective interoperability between the UAS DAA system and the Traffic Alert and Collision Avoidance System (TCAS) was observed with one notable exception: TCAS Resolutions Advisories (RA) were observed in the absence of any DAA alert on two occasions, indicating the need for alert parameter refinement. Findings further indicated the need for continued work in the areas of DAA Well Clear Recovery logic and alert stability for Mode-C-only intruders. Finally, results demonstrated a high level of compliance with a set of evaluation criteria designed to provide anecdotal evidence of acceptable UAS DAA system performance.

  10. Extending the limits of operating pressure of narrow-bore column liquid chromatography instrumentation.

    PubMed

    Pauw, Ruben De; Degreef, Bart; Ritchie, Harald; Eeltink, Sebastiaan; Desmet, Gert; Broeckhoven, Ken

    2014-06-20

    The increase of the operating pressure in Liquid Chromatography, has been one of the crucial steps toward faster and more efficient separations. In the present contribution, it was investigated if the pressure limits for narrow-bore columns (2.1mm ID) could be increased beyond those of commercially available (1300bar) instrumentation without performance loss. Whereas previous studies applying pressures higher than 2000bar were limited to the use of columns with a diameter smaller or equal to 1mm, it is a difficult feat to expand this to 2.1mm ID given that viscous-heating effects increase according to the fifth power of the column radius. A prototype LC set-up was realized, allowing to operate at pressures up to 2600bar (260MPa) for large separation volumes (>5mL). The performance of an in-house-built injector was compared at 800bar to commercially available injectors, yielding equal performance but twice the maximum pressure rating. The performance of (coupled) custom columns packed with fully porous and superficially porous particles were assessed at ultra-high-pressure conditions. Increasing the inlet pressure from 800 to 2400bar and scaling the column length proportionally (from 150mm to 450mm), resulted in the theoretically expected linear increase in plate count from 20,000 to 59,000. A maximum plate number of 81,000 was realized using a 600mm long (coupled) column at 2600bar. Viscous-heating effects were diminished by insulating coupled columns and applying an intermediate-cooling strategy in a forced-air oven. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Public Release of Estimated Impact-Based Earthquake Alerts - An Update to the U.S. Geological Survey PAGER System

    NASA Astrophysics Data System (ADS)

    Wald, D. J.; Jaiswal, K. S.; Marano, K.; Hearne, M.; Earle, P. S.; So, E.; Garcia, D.; Hayes, G. P.; Mathias, S.; Applegate, D.; Bausch, D.

    2010-12-01

    The U.S. Geological Survey (USGS) has begun publicly releasing earthquake alerts for significant earthquakes around the globe based on estimates of potential casualties and economic losses. These estimates should significantly enhance the utility of the USGS Prompt Assessment of Global Earthquakes for Response (PAGER) system that has been providing estimated ShakeMaps and computing population exposures to specific shaking intensities since 2007. Quantifying earthquake impacts and communicating loss estimates (and their uncertainties) to the public has been the culmination of several important new and evolving components of the system. First, the operational PAGER system now relies on empirically-based loss models that account for estimated shaking hazard, population exposure, and employ country-specific fatality and economic loss functions derived using analyses of losses due to recent and past earthquakes. In some countries, our empirical loss models are informed in part by PAGER’s semi-empirical and analytical loss models, and building exposure and vulnerability data sets, all of which are being developed in parallel to the empirical approach. Second, human and economic loss information is now portrayed as a supplement to existing intensity/exposure content on both PAGER summary alert (available via cell phone/email) messages and web pages. Loss calculations also include estimates of the economic impact with respect to the country’s gross domestic product. Third, in order to facilitate rapid and appropriate earthquake responses based on our probable loss estimates, in early 2010 we proposed a four-level Earthquake Impact Scale (EIS). Instead of simply issuing median estimates for losses—which can be easily misunderstood and misused—this scale provides ranges of losses from which potential responders can gauge expected overall impact from strong shaking. EIS is based on two complementary criteria: the estimated cost of damage, which is most suitable for U.S. domestic events; and estimated ranges of fatalities, which are generally more appropriate for global events, particularly in earthquake-vulnerable countries. Alert levels are characterized by alerts of green (little or no impact), yellow (regional impact and response), orange (national-scale impact and response), and red (international response). Corresponding fatality thresholds for yellow, orange, and red alert levels are 1, 100, and 1000, respectively. For damage impact, yellow, orange, and red thresholds are triggered when estimated US dollar losses reach 1 million, 100 million, and 1 billion+ levels, respectively. Finally, alerting protocols now explicitly support EIS-based alerts. Critical users can receive PAGER alerts i) based on the EIS-based alert level, in addition to or as an alternative to magnitude and population/intensity exposure-based alerts, and ii) optionally, based on user-selected regions of the world. The essence of PAGER’s impact-based alerting is that actionable loss information is now available in the immediate aftermath of significant earthquakes worldwide based on quantifiable, albeit uncertain, loss estimates provided by the USGS.

  12. Augmented real-time navigation with critical structure proximity alerts for endoscopic skull base surgery.

    PubMed

    Dixon, Benjamin J; Daly, Michael J; Chan, Harley; Vescan, Allan; Witterick, Ian J; Irish, Jonathan C

    2014-04-01

    Image-guided surgery (IGS) systems are frequently utilized during cranial base surgery to aid in orientation and facilitate targeted surgery. We wished to assess the performance of our recently developed localized intraoperative virtual endoscopy (LIVE)-IGS prototype in a preclinical setting prior to deployment in the operating room. This system combines real-time ablative instrument tracking, critical structure proximity alerts, three-dimensional virtual endoscopic views, and intraoperative cone-beam computed tomographic image updates. Randomized-controlled trial plus qualitative analysis. Skull base procedures were performed on 14 cadaver specimens by seven fellowship-trained skull base surgeons. Each subject performed two endoscopic transclival approaches; one with LIVE-IGS and one using a conventional IGS system in random order. National Aeronautics and Space Administration Task Load Index (NASA-TLX) scores were documented for each dissection, and a semistructured interview was recorded for qualitative assessment. The NASA-TLX scores for mental demand, effort, and frustration were significantly reduced with the LIVE-IGS system in comparison to conventional navigation (P < .05). The system interface was judged to be intuitive and most useful when there was a combination of high spatial demand, reduced or absent surface landmarks, and proximity to critical structures. The development of auditory icons for proximity alerts during the trial better informed the surgeon while limiting distraction. The LIVE-IGS system provided accurate, intuitive, and dynamic feedback to the operating surgeon. Further refinements to proximity alerts and visualization settings will enhance orientation while limiting distraction. The system is currently being deployed in a prospective clinical trial in skull base surgery. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Optical flow and driver's kinematics analysis for state of alert sensing.

    PubMed

    Jiménez-Pinto, Javier; Torres-Torriti, Miguel

    2013-03-28

    Road accident statistics from different countries show that a significant number of accidents occur due to driver's fatigue and lack of awareness to traffic conditions. In particular, about 60% of the accidents in which long haul truck and bus drivers are involved are attributed to drowsiness and fatigue. It is thus fundamental to improve non-invasive systems for sensing a driver's state of alert. One of the main challenges to correctly resolve the state of alert is measuring the percentage of eyelid closure over time (PERCLOS), despite the driver's head and body movements. In this paper, we propose a technique that involves optical flow and driver's kinematics analysis to improve the robustness of the driver's alert state measurement under pose changes using a single camera with near-infrared illumination. The proposed approach infers and keeps track of the driver's pose in 3D space in order to ensure that eyes can be located correctly, even after periods of partial occlusion, for example, when the driver stares away from the camera. Our experiments show the effectiveness of the approach with a correct eyes detection rate of 99.41%, on average. The results obtained with the proposed approach in an experiment involving fifteen persons under different levels of sleep deprivation also confirm the discriminability of the fatigue levels. In addition to the measurement of fatigue and drowsiness, the pose tracking capability of the proposed approach has potential applications in distraction assessment and alerting of machine operators.

  14. IR panoramic alerting sensor concepts and applications

    NASA Astrophysics Data System (ADS)

    de Jong, Arie N.; Schwering, Piet B. W.

    2003-09-01

    During the last decade, protection of military and civilian operational platforms against weapons like guns, grenades, missiles, Unmanned Combat Aerial (and surface) Vehicles (UCAV's) and mines, has been an issue of increased importance due to the improved kill-probability of these threats. The standard countermeasure package of armour, guns, decoys, jammers, camouflage nets and smokes is inadequate when not accompanied by a suitable sensor package, primarily consisting of an alerting device, triggering consecutive steps in the countermeasure-chain. In this process of alert four different detection techniques are considered: pre-alert, giving the directions of possible attack, detection of an action of attack, identification of the threat and finally the precise localization (3-D). The design of the alerting device is greatly depending on the platform, on which it will be used, the associated and affordable cost and the nature of the threat. A number of sensor packages, considered, developed and evaluated at TNO-FEL is presented for simple, medium size and large and expensive platforms. In recent years the requirements for these sensors have become more and more strigent due to the growing number of scenarios. The attack can practically be from any direction, implying the need for a large Field of Regard (FOR), the attack range can vary considerably and the type of threat can be very diverse, implying great flexibility and dynamic range and rapid response of the sensor. Especially the localization at short ranges is a challenging issue. Various configurations including advantages and drawbacks are discussed.

  15. Optical Flow and Driver's Kinematics Analysis for State of Alert Sensing

    PubMed Central

    Jiménez-Pinto, Javier; Torres-Torriti, Miguel

    2013-01-01

    Road accident statistics from different countries show that a significant number of accidents occur due to driver's fatigue and lack of awareness to traffic conditions. In particular, about 60% of the accidents in which long haul truck and bus drivers are involved are attributed to drowsiness and fatigue. It is thus fundamental to improve non-invasive systems for sensing a driver's state of alert. One of the main challenges to correctly resolve the state of alert is measuring the percentage of eyelid closure over time (PERCLOS), despite the driver's head and body movements. In this paper, we propose a technique that involves optical flow and driver's kinematics analysis to improve the robustness of the driver's alert state measurement under pose changes using a single camera with near-infrared illumination. The proposed approach infers and keeps track of the driver's pose in 3D space in order to ensure that eyes can be located correctly, even after periods of partial occlusion, for example, when the driver stares away from the camera. Our experiments show the effectiveness of the approach with a correct eyes detection rate of 99.41%, on average. The results obtained with the proposed approach in an experiment involving fifteen persons under different levels of sleep deprivation also confirm the discriminability of the fatigue levels. In addition to the measurement of fatigue and drowsiness, the pose tracking capability of the proposed approach has potential applications in distraction assessment and alerting of machine operators. PMID:23539029

  16. Sleep, alertness and alertness management among commercial airline pilots on short-haul and long-haul flights.

    PubMed

    Sallinen, Mikael; Sihvola, Maria; Puttonen, Sampsa; Ketola, Kimmo; Tuori, Antti; Härmä, Mikko; Kecklund, Göran; Åkerstedt, Torbjörn

    2017-01-01

    Airline pilots' sleep and on-duty alertness are important focus areas in commercial aviation. Until now, studies pertaining to this topic have mainly focused on specific characteristics of flights and thus a comprehensive picture of the matter is not well established. In addition, research knowledge of what airline pilots actually do to maintain their alertness while being on duty is scarce. To address these gaps in research knowledge, we conducted a field study on a representative sample of the airline pilots of a medium-sized airline. The sample consisted of 90 pilots, of whom 30 flew long-haul (LH) routes, 30 short-haul (SH) routes, and 30 flew both. A total of 86 pilots completed the measurements that lasted for almost two months per pilot. The measurements resulted in a total of 965 flight duty periods (FDPs) including SH flights and 627 FDPs including LH flights. During the measurement periods, sleep was measured by a diary and actigraphs, on-duty alertness by the Karolinska Sleepiness Scale (KSS) in all flight phases, and on-duty alertness management strategies by the diary. Results showed that SH and LH FDPs covering the whole domicile night (00:00-06:00 at home base) were most consistently associated with reduced sleep-wake ratio and subjective alertness. Approximately every 3rd FDP falling into this category involved a reduced sleep-wake ratio (1:3 or lower) and every 2nd a reduced level of subjective alertness (KSS rating 8-9 in at least one flight phase). The corresponding frequencies for the SH and LH FDPs that partly covered the domicile night were every 10th and every 5th FDP and for the pure non-night FDPs every 30th and every 36th FDP, respectively. The results also showed that the pilots tended to increase the use of effective on-duty alertness management strategies (consuming alertness-promoting products and taking strategic naps) in connection with the FDPs that overlapped the domicile night. Finally, the results showed that the frequency of flights involving reduced subjective alertness depended on how alertness was assessed. If it was assessed solely in the flight phase just before starting the landing procedures (top of descent) the phenomenon was less frequent than if the preceding cruise phase was also taken into account. Our results suggest that FDPs covering the whole domicile night should be prioritised over the other FDPs in fatigue management, regardless of whether an FDP is a short-haul or a long-haul. In addition, the identification of fatigue in flight operations requires one to assess pilots' alertness across all flight phases, not only at ToD. Due to limitations in our data, these conclusions can, however, be generalise to only LH FDPs during which pilots can be expected to be well acclimatised to the local time at their home base and SH night FDPs that include at least 3h of flying in the cruise phase. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Evaluating two process scale chromatography column header designs using CFD.

    PubMed

    Johnson, Chris; Natarajan, Venkatesh; Antoniou, Chris

    2014-01-01

    Chromatography is an indispensable unit operation in the downstream processing of biomolecules. Scaling of chromatographic operations typically involves a significant increase in the column diameter. At this scale, the flow distribution within a packed bed could be severely affected by the distributor design in process scale columns. Different vendors offer process scale columns with varying design features. The effect of these design features on the flow distribution in packed beds and the resultant effect on column efficiency and cleanability needs to be properly understood in order to prevent unpleasant surprises on scale-up. Computational Fluid Dynamics (CFD) provides a cost-effective means to explore the effect of various distributor designs on process scale performance. In this work, we present a CFD tool that was developed and validated against experimental dye traces and tracer injections. Subsequently, the tool was employed to compare and contrast two commercially available header designs. © 2014 American Institute of Chemical Engineers.

  18. Effects of operating practices on commercial driver alertness

    DOT National Transportation Integrated Search

    2011-08-01

    This report presents the test plan for collecting and analyzing data dealing with travel demand management (TDM) activities for the Atlanta Congestion Reduction Demonstration (CRD) under the United States Department of Transportation (U.S. DOT) Urban...

  19. Very high-energy gamma-ray follow-up program using neutrino triggers from IceCube

    NASA Astrophysics Data System (ADS)

    IceCube Collaboration; Aartsen, M. G.; Abraham, K.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Altmann, D.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Archinger, M.; Argüelles, C.; Auffenberg, J.; Axani, S.; Bai, X.; Barwick, S. W.; Baum, V.; Bay, R.; Beatty, J. J.; Becker Tjus, J.; Becker, K.-H.; BenZvi, S.; Berley, D.; Bernardini, E.; Bernhard, A.; Besson, D. Z.; Binder, G.; Bindig, D.; Bissok, M.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Bos, F.; Bose, D.; Böser, S.; Botner, O.; Braun, J.; Brayeur, L.; Bretz, H.-P.; Bron, S.; Burgman, A.; Carver, T.; Casier, M.; Cheung, E.; Chirkin, D.; Christov, A.; Clark, K.; Classen, L.; Coenders, S.; Collin, G. H.; Conrad, J. M.; Cowen, D. F.; Cross, R.; Day, M.; de André, J. P. A. M.; De Clercq, C.; del Pino Rosendo, E.; Dembinski, H.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Díaz-Vélez, J. C.; di Lorenzo, V.; Dujmovic, H.; Dumm, J. P.; Dunkman, M.; Eberhardt, B.; Ehrhardt, T.; Eichmann, B.; Eller, P.; Euler, S.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Feintzeig, J.; Felde, J.; Filimonov, K.; Finley, C.; Flis, S.; Fösig, C.-C.; Franckowiak, A.; Franke, R.; Friedman, E.; Fuchs, T.; Gaisser, T. K.; Gallagher, J.; Gerhardt, L.; Ghorbani, K.; Giang, W.; Gladstone, L.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Golup, G.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Haack, C.; Haj Ismail, A.; Hallgren, A.; Halzen, F.; Hansen, E.; Hansmann, T.; Hanson, K.; Hebecker, D.; Heereman, D.; Helbing, K.; Hellauer, R.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Holzapfel, K.; Hoshina, K.; Huang, F.; Huber, M.; Hultqvist, K.; In, S.; Ishihara, A.; Jacobi, E.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Jurkovic, M.; Kappes, A.; Karg, T.; Karle, A.; Katz, U.; Kauer, M.; Keivani, A.; Kelley, J. L.; Kheirandish, A.; Kim, M.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Kohnen, G.; Koirala, R.; Kolanoski, H.; Konietz, R.; Köpke, L.; Kopper, C.; Kopper, S.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Kroll, M.; Krückl, G.; Krüger, C.; Kunnen, J.; Kunwar, S.; Kurahashi, N.; Kuwabara, T.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lennarz, D.; Lesiak-Bzdak, M.; Leuermann, M.; Lu, L.; Lünemann, J.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Mancina, S.; Mandelartz, M.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Meier, M.; Meli, A.; Menne, T.; Merino, G.; Meures, T.; Miarecki, S.; Mohrmann, L.; Montaruli, T.; Moulai, M.; Nahnhauer, R.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Obertacke Pollmann, A.; Olivas, A.; O'Murchadha, A.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Peiffer, P.; Penek, Ö.; Pepper, J. A.; Pérez de los Heros, C.; Pieloth, D.; Pinat, E.; Price, P. B.; Przybylski, G. T.; Quinnan, M.; Raab, C.; Rädel, L.; Rameez, M.; Rawlins, K.; Reimann, R.; Relethford, B.; Relich, M.; Resconi, E.; Rhode, W.; Richman, M.; Riedel, B.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Sabbatini, L.; Sanchez Herrera, S. E.; Sandrock, A.; Sandroos, J.; Sarkar, S.; Satalecka, K.; Schlunder, P.; Schmidt, T.; Schoenen, S.; Schöneberg, S.; Schumacher, L.; Seckel, D.; Seunarine, S.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stanev, T.; Stasik, A.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Ström, R.; Strotjohann, N. L.; Sullivan, G. W.; Sutherland, M.; Taavola, H.; Taboada, I.; Tatar, J.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tešić, G.; Tilav, S.; Toale, P. A.; Tobin, M. N.; Toscano, S.; Tosi, D.; Tselengidou, M.; Turcati, A.; Unger, E.; Usner, M.; Vandenbroucke, J.; van Eijndhoven, N.; Vanheule, S.; van Rossem, M.; van Santen, J.; Veenkamp, J.; Vehring, M.; Voge, M.; Vogel, E.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandkowsky, N.; Weaver, Ch.; Weiss, M. J.; Wendt, C.; Westerhoff, S.; Whelan, B. J.; Wickmann, S.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, T. R.; Woolsey, E.; Woschnagg, K.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Zoll, M.; MAGIC Collaboration; Ahnen, M. L.; Ansoldi, S.; Antonelli, L. A.; Antoranz, P.; Babic, A.; Banerjee, B.; Bangale, P.; Barres de Almeida, U.; Barrio, J. A.; Becerra González, J.; Bednarek, W.; Bernardini, E.; Berti, A.; Biasuzzi, B.; Biland, A.; Blanch, O.; Bonnefoy, S.; Bonnoli, G.; Borracci, F.; Bretz, T.; Buson, S.; Carosi, A.; Chatterjee, A.; Clavero, R.; Colin, P.; Colombo, E.; Contreras, J. L.; Cortina, J.; Covino, S.; Da Vela, P.; Dazzi, F.; De Angelis, A.; De Lotto, B.; de Oña Wilhelmi, E.; Di Pierro, F.; Doert, M.; Domínguez, A.; Dominis Prester, D.; Dorner, D.; Doro, M.; Einecke, S.; Eisenacher Glawion, D.; Elsaesser, D.; Engelkemeier, M.; Fallah Ramazani, V.; Fernández-Barral, A.; Fidalgo, D.; Fonseca, M. V.; Font, L.; Frantzen, K.; Fruck, C.; Galindo, D.; García López, R. J.; Garczarczyk, M.; Garrido Terrats, D.; Gaug, M.; Giammaria, P.; Godinović, N.; González Muñoz, A.; Góra, D.; Guberman, D.; Hadasch, D.; Hahn, A.; Hanabata, Y.; Hayashida, M.; Herrera, J.; Hose, J.; Hrupec, D.; Hughes, G.; Idec, W.; Kodani, K.; Konno, Y.; Kubo, H.; Kushida, J.; La Barbera, A.; Lelas, D.; Lindfors, E.; Lombardi, S.; Longo, F.; López, M.; López-Coto, R.; Majumdar, P.; Makariev, M.; Mallot, K.; Maneva, G.; Manganaro, M.; Mannheim, K.; Maraschi, L.; Marcote, B.; Mariotti, M.; Martínez, M.; Mazin, D.; Menzel, U.; Miranda, J. M.; Mirzoyan, R.; Moralejo, A.; Moretti, E.; Nakajima, D.; Neustroev, V.; Niedzwiecki, A.; Nievas Rosillo, M.; Nilsson, K.; Nishijima, K.; Noda, K.; Nogués, L.; Overkemping, A.; Paiano, S.; Palacio, J.; Palatiello, M.; Paneque, D.; Paoletti, R.; Paredes, J. M.; Paredes-Fortuny, X.; Pedaletti, G.; Peresano, M.; Perri, L.; Persic, M.; Poutanen, J.; Prada Moroni, P. G.; Prandini, E.; Puljak, I.; Reichardt, I.; Rhode, W.; Ribó, M.; Rico, J.; Rodriguez Garcia, J.; Saito, T.; Satalecka, K.; Schroeder, S.; Schultz, C.; Schweizer, T.; Sillanpää, A.; Sitarek, J.; Snidaric, I.; Sobczynska, D.; Stamerra, A.; Steinbring, T.; Strzys, M.; Surić, T.; Takalo, L.; Tavecchio, F.; Temnikov, P.; Terzić, T.; Tescaro, D.; Teshima, M.; Thaele, J.; Torres, D. F.; Toyama, T.; Treves, A.; Vanzo, G.; Verguilov, V.; Vovk, I.; Ward, J. E.; Will, M.; Wu, M. H.; Zanin, .; VERITAS Collaboration; Abeysekara, A. U.; Archambault, S.; Archer, A.; Benbow, W.; Bird, R.; Bourbeau, E.; Buchovecky, M.; Bugaev, V.; Byrum, K.; Cardenzana, J. V.; Cerruti, M.; Ciupik, L.; Connolly, M. P.; Cui, W.; Dickinson, H. J.; Dumm, J.; Eisch, J. D.; Errando, M.; Falcone, A.; Feng, Q.; Finley, J. P.; Fleischhack, H.; Flinders, A.; Fortson, L.; Furniss, A.; Gillanders, G. H.; Griffin, S.; Hütten, J. Grube M.; Håkansson, N.; Hervet, O.; Holder, J.; Humensky, T. B.; Johnson, C. A.; Kaaret, P.; Kar, P.; Kelley-Hoskins, N.; Kertzman, M.; Kieda, D.; Krause, M.; Krennrich, F.; Kumar, S.; Lang, M. J.; Maier, G.; McArthur, S.; McCann, A.; Moriarty, P.; Mukherjee, R.; Nguyen, T.; Nieto, D.; O'Brien, S.; Ong, R. A.; Otte, A. N.; Park, N.; Pohl, M.; Popkow, A.; Pueschel, E.; Quinn, J.; Ragan, K.; Reynolds, P. T.; Richards, G. T.; Roache, E.; Rulten, C.; Sadeh, I.; Santander, M.; Sembroski, G. H.; Shahinyan, K.; Staszak, D.; Telezhinsky, I.; Tucci, J. V.; Tyler, J.; Wakely, S. P.; Weinstein, A.; Wilcox, P.; Wilhelm, A.; Williams, D. A.; Zitzer, B.

    2016-11-01

    We describe and report the status of a neutrino-triggered program in IceCube that generates real-time alerts for gamma-ray follow-up observations by atmospheric-Cherenkov telescopes (MAGIC and VERITAS). While IceCube is capable of monitoring the whole sky continuously, high-energy gamma-ray telescopes have restricted fields of view and in general are unlikely to be observing a potential neutrino-flaring source at the time such neutrinos are recorded. The use of neutrino-triggered alerts thus aims at increasing the availability of simultaneous multi-messenger data during potential neutrino flaring activity, which can increase the discovery potential and constrain the phenomenological interpretation of the high-energy emission of selected source classes (e.g. blazars). The requirements of a fast and stable online analysis of potential neutrino signals and its operation are presented, along with first results of the program operating between 14 March 2012 and 31 December 2015.

  20. Cockpit napping

    NASA Technical Reports Server (NTRS)

    Graeber, R. Curtis; Rosekind, Mark R.; Connell, Linda J.; Dinges, David F.

    1990-01-01

    The results of a NASA-sponsored study examining the effectiveness of a brief, preplanned cockpit rest period to improve pilot alertness and performance in nonaugmented long-haul flight operations are discussed. Four regularly scheduled trans-Pacific flight legs were studied. The shortest flight legs were about 7 h and the longest about 9.5 h, with duty periods averaging about 11 h and layovers about 25 h. Three-person B747 crews were divided randomly into two volunteer pilot groups. These crews were nonaugmented, and therefore no relief pilots were available. The rest group, consisting of four crews, was allowed a 40 min opportunity to rest during the overwater cruise portion of the flight. On a preplanned, rotating basis, individual crew members were allowed to nap. It is concluded that a preplanned cockpit nap is associated with significantly better behavioral performance and higher levels of physiological alertness and that this can be accomplished without disrupting normal flight operations or compromising safety.

  1. A practicable process for phenol removal with liquid surfactant membrane permeation column

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kataoka, Takeshi; Osaki, Katsuhiko; Nishiki, Tadaaki

    1997-05-01

    A practicable liquid surfactant membrane process for phenol removal is proposed with a stirred countercurrent column used as the liquid membrane contact equipment. The constituents of liquid membranes, such as internal aqueous phase and surfactant, the type of column, and the operating conditions for efficient and continuous performance of the liquid surfactant membrane process, have been examined. When NaOH solution was used as the internal aqueous phase and ECA4360J was used as the surfactant, the W/O emulsion was stable for the duration of column operation. More than 97% phenol could be removed from the feed solution. Nearly complete demulsification wasmore » also achieved by gentle agitation with an electrostatic demulsifier.« less

  2. The Hellenic National Tsunami Warning Centre (HL-NTWC): Recent updates and future developments

    NASA Astrophysics Data System (ADS)

    Melis, Nikolaos S.; Charalampakis, Marinos

    2014-05-01

    The Hellenic NTWC (HL-NTWC) was established officially by Greek Law in September 2010. HL-NTWC is hosted at the National Observatory of Athens, Institute of Geodynamics (NOA-IG), which also operates a 24/7 earthquake monitoring service in Greece and coordinates the newly established Hellenic Unified National Seismic Network. NOA-IG and HL-NTWC Operational Centre is linked to the Civil Protection Operational Centre and serves as the official alerting agency to the General Secretariat for Civil Protection in Greece, regarding earthquake events and tsunami watch. Since August 2012, HL-NTWC acts as Candidate Tsunami Watch Provider (CTWP) under the UNESCO IOC - ICG NEAMTWS tsunami warning system (NEAM: North-Eastern Atlantic, the Mediterranean and connected seas) and offers its services to the NEAMTWS system. HL-NTWC has participated in all Communication Test Exercises (CTE) under NEAMTWS and also it has provided tsunami scenarios for extended system testing exercises such as NEAMWAVE12. Some of the recent developments at HL-NTWC in Greece include: deployment of new tide gauge stations for tsunami watch purposes, computation of tsunami scenarios and extending the database in use, improving alerting response times, earthquake magnitude estimation and testing newly established software modules for tsunami and earthquake alerting (i.e. Early-Est, SeisComP3 etc.) in Greece and the Eastern Mediterranean. Although funding today is limited, an advantage of the participation in important EC funded research projects, i.e. NERIES, NERA, TRANSFER, NEAMTIC and ASTARTE, demonstrates that collaboration of top class Research Institutions that care to produce important and useful results in the research front in Europe, can facilitate towards developing and operating top class Operational Centers, useful for Civil Protection purposes in regions in need. Last, it is demonstrated that HL-NTWC collaboration with important key role Research Centers in the Security and Safety issues (e.g. JRC-IPSC) at the Operational front, can further facilitate and secure everyday operation under a collaborative and experience exchanging manner. This work is funded by project ASTARTE - Assessment, STrategy And Risk Reduction for Tsunamis in Europe. Grant 603839, 7th FP (ENV.2013.6.4-3 ENV.2013.6.4-3)

  3. Finite-Fault and Other New Capabilities of CISN ShakeAlert

    NASA Astrophysics Data System (ADS)

    Boese, M.; Felizardo, C.; Heaton, T. H.; Hudnut, K. W.; Hauksson, E.

    2013-12-01

    Over the past 6 years, scientists at Caltech, UC Berkeley, the Univ. of Southern California, the Univ. of Washington, the US Geological Survey, and ETH Zurich (Switzerland) have developed the 'ShakeAlert' earthquake early warning demonstration system for California and the Pacific Northwest. We have now started to transform this system into a stable end-to-end production system that will be integrated into the daily routine operations of the CISN and PNSN networks. To quickly determine the earthquake magnitude and location, ShakeAlert currently processes and interprets real-time data-streams from several hundred seismic stations within the California Integrated Seismic Network (CISN) and the Pacific Northwest Seismic Network (PNSN). Based on these parameters, the 'UserDisplay' software predicts and displays the arrival and intensity of shaking at a given user site. Real-time ShakeAlert feeds are currently being shared with around 160 individuals, companies, and emergency response organizations to gather feedback about the system performance, to educate potential users about EEW, and to identify needs and applications of EEW in a future operational warning system. To improve the performance during large earthquakes (M>6.5), we have started to develop, implement, and test a number of new algorithms for the ShakeAlert system: the 'FinDer' (Finite Fault Rupture Detector) algorithm provides real-time estimates of locations and extents of finite-fault ruptures from high-frequency seismic data. The 'GPSlip' algorithm estimates the fault slip along these ruptures using high-rate real-time GPS data. And, third, a new type of ground-motion prediction models derived from over 415,000 rupture simulations along active faults in southern California improves MMI intensity predictions for large earthquakes with consideration of finite-fault, rupture directivity, and basin response effects. FinDer and GPSlip are currently being real-time and offline tested in a separate internal ShakeAlert installation at Caltech. Real-time position and displacement time series from around 100 GPS sensors are obtained in JSON format from RTK/PPP(AR) solutions using the RTNet software at USGS Pasadena. However, we have also started to investigate the usage of onsite (in-receiver) processing using NetR9 with RTX and tracebuf2 output format. A number of changes to the ShakeAlert processing, xml message format, and the usage of this information in the UserDisplay software were necessary to handle the new finite-fault and slip information from the FinDer and GPSlip algorithms. In addition, we have developed a framework for end-to-end off-line testing with archived and simulated waveform data using the Earthworm tankplayer. Detailed background information about the algorithms, processing, and results from these test runs will be presented.

  4. PEM fuel cell monitoring system

    DOEpatents

    Meltser, Mark Alexander; Grot, Stephen Andreas

    1998-01-01

    Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

  5. Real-time Affective Indices of Potential CRM Breakdown: Qualitative Testing of an Operational Hypothesis

    NASA Technical Reports Server (NTRS)

    Dickerson, Mark

    2007-01-01

    This viewgraph presentation begins by showing several cases where poor crew resource management (CRM) resulted in aircraft accidents. The presenter reviews the emotional states that are present in a situation that frequently leads to an accident. The operational answer suggested is given as an acronym: PACE, which stand for Probe, Alert, Challenge, Emergency Action.

  6. Integrated Land- and Underwater-Based Sensors for a Subduction Zone Earthquake Early Warning System

    NASA Astrophysics Data System (ADS)

    Pirenne, B.; Rosenberger, A.; Rogers, G. C.; Henton, J.; Lu, Y.; Moore, T.

    2016-12-01

    Ocean Networks Canada (ONC — oceannetworks.ca/ ) operates cabled ocean observatories off the coast of British Columbia (BC) to support research and operational oceanography. Recently, ONC has been funded by the Province of BC to deliver an earthquake early warning (EEW) system that integrates offshore and land-based sensors to deliver alerts of incoming ground shaking from the Cascadia Subduction Zone. ONC's cabled seismic network has the unique advantage of being located offshore on either side of the surface expression of the subduction zone. The proximity of ONC's sensors to the fault can result in faster, more effective warnings, which translates into more lives saved, injuries avoided and more ability for mitigative actions to take place.ONC delivers near real-time data from various instrument types simultaneously, providing distinct advantages to seismic monitoring and earthquake early warning. The EEW system consists of a network of sensors, located on the ocean floor and on land, that detect and analyze the initial p-wave of an earthquake as well as the crustal deformation on land during the earthquake sequence. Once the p-wave is detected and characterized, software systems correlate the data streams of the various sensors and deliver alerts to clients through a Common Alerting Protocol-compliant data package. This presentation will focus on the development of the earthquake early warning capacity at ONC. It will describe the seismic sensors and their distribution, the p-wave detection algorithms selected and the overall architecture of the system. It will further overview the plan to achieve operational readiness at project completion.

  7. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts

    PubMed Central

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras

    2016-01-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101

  8. Collision Avoidance for Airport Traffic Concept Evaluation

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III; Otero, Sharon D.; Barker, Glover D.

    2009-01-01

    An initial Collision Avoidance for Airport Traffic (CAAT) concept for the Terminal Maneuvering Area (TMA) was evaluated in a simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center. CAAT is being designed to enhance surface situation awareness and provide cockpit alerts of potential conflicts during runway, taxi, and low altitude air-to-air operations. The purpose of the study was to evaluate the initial concept for an aircraft-based method of conflict detection and resolution (CD&R) in the TMA focusing on conflict detection algorithms and alerting display concepts. This paper gives an overview of the CD&R concept, simulation study, and test results.

  9. Earthquake Early Warning: New Strategies for Seismic Hardware

    NASA Astrophysics Data System (ADS)

    Allardice, S.; Hill, P.

    2017-12-01

    Implementing Earthquake Early Warning System (EEWS) triggering algorithms into seismic networks has been a hot topic of discussion for some years now. With digitizer technology now available, such as the Güralp Minimus, with on average 40-60ms delay time (latency) from earthquake origin to issuing an alert the next step is to provide network operators with a simple interface for on board parameter calculations from a seismic station. A voting mechanism is implemented on board which mitigates the risk of false positives being communicated. Each Minimus can be configured to with a `score' from various sources i.e. Z channel on seismometer, N/S E/W channels on accelerometer and MEMS inside Minimus. If the score exceeds the set threshold then an alert is sent to the `Master Minimus'. The Master Minimus within the network will also be configured as to when the alert should be issued i.e. at least 3 stations must have triggered. Industry standard algorithms focus around the calculation of Peak Ground Acceleration (PGA), Peak Ground Velocity (PGV), Peak Ground Displacement (PGD) and C. Calculating these single station parameters on-board in order to stream only the results could help network operators with possible issues, such as restricted bandwidth. Developments on the Minimus allow these parameters to be calculated and distributed through Common Alert Protocol (CAP). CAP is the XML based data format used for exchanging and describing public warnings and emergencies. Whenever the trigger conditions are met the Minimus can send a signed UDP packet to the configured CAP receiver which can then send the alert via SMS, e-mail or CAP forwarding. Increasing network redundancy is also a consideration when developing these features, therefore the forwarding CAP message can be sent to multiple destinations. This allows for a hierarchical approach by which the single station (or network) parameters can be streamed to another Minimus, or data centre, or both, so that there is no one single point of failure. Developments on the Guralp Minimus to calculate these on board parameters which are capable of streaming single station parameters, accompanied with the ultra-low latency is the next generation of EEWS and Güralps contribution to the community.

  10. Developing a reliable method for signal wire attachment : [research results].

    DOT National Transportation Integrated Search

    2013-03-01

    Railroad signaling systems detect trains on the track, identify track fractures, prevent derailments, and alert signal crossing stations when trains approach. These systems are vital to safe train operation; therefore, each component of this system h...

  11. Maintaining vigilance on a simulated ATC monitoring task across repeated sessions.

    DOT National Transportation Integrated Search

    1994-03-01

    Maintaining alertness to information provided visually is an important aspect of air traffic controllers' work. Improper or incomplete scanning and monitoring behavior is often referred to as one of the causal factors associated with operational erro...

  12. VHF-FM Emergency Position Indicating Radio Beacon

    DOT National Transportation Integrated Search

    1978-10-01

    This report describes the development and testing of an Emergency Position Indicating Radio Beacon (EPIRB) which operates on Channels 15 and 16 of the Maritime Mobile VHF Band. It provides functions necessary to ensure that distress alerting and loca...

  13. Operational Use of the AIRS Total Column Ozone Retrievals Along with the RGB Air Mass Product as Part of the GOES-R Proving Ground

    NASA Technical Reports Server (NTRS)

    Folmer, Michael; Zavodsky, Bradley; Molthan, Andrew

    2012-01-01

    The National Oceanic and Atmospheric Administration (NOAA) National Centers for Environmental Prediction (NCEP) Hydrometeorological Prediction Center (HPC) and Ocean Prediction Center (OPC) provide short-term and medium-range forecast guidance of heavy precipitation, strong winds, and other features often associated with mid-latitude cyclones over both land and ocean. As a result, detection of factors that lead to rapid cyclogenesis and high wind events is key to improving forecast skill. One phenomenon that has been identified with these events is the stratospheric intrusion that occurs near tropopause folds. This allows for deep mixing near the top of the atmosphere where dry air high in ozone concentrations and potential vorticity descends (sometimes rapidly) deep into the mid-troposphere. Observations from satellites can aid in detection of these stratospheric air intrusions (SAI) regions. Specifically, multispectral composite imagery assign a variety of satellite spectral bands to the red, green, and blue (RGB) color components of imagery pixels and result in color combinations that can assist in the detection of dry stratospheric air associated with PV advection, which in turn may alert forecasters to the possibility of a rapidly strengthening storm system. Single channel or RGB satellite imagery lacks quantitative information about atmospheric moisture unless the sampled brightness temperatures or other data are converted to estimates of moisture via a retrieval process. Thus, complementary satellite observations are needed to capture a complete picture of a developing storm system. Here, total column ozone retrievals derived from a hyperspectral sounder are used to confirm the extent and magnitude of SAIs. Total ozone is a good proxy for defining locations and intensity of SAIs and has been used in studies evaluating that phenomenon (e.g. Tian et al. 2007, Knox and Schmidt 2005). Steep gradients in values of total ozone seen by satellites have been linked to stratosphere-troposphere exchange (WMO, 1985).

  14. Effect of operating conditions on the removal of Pb2+ by microporous titanosilicate ETS-10 in a fixed-bed column.

    PubMed

    Lv, Lu; Wang, Kean; Zhao, X S

    2007-01-15

    The breakthrough behavior of Pb2+ in an ETS-10 fixed bed was experimentally examined at various operating conditions. Results showed that the adsorption amount of Pb2+ ions per unit mass of ETS-10 particles in a column is about 1.68 mmol/g under the experimental conditions. This amount was not markedly affected by the operating conditions because of the rapid adsorption rate of Pb2+ ions on ETS-10. In the presence of competitive metal ions, the amount of Pb2+ adsorbed on ETS-10 was slightly reduced. An overshoot of the effluent concentrations of competitive metal ions Cu2+ and Cd2+ was observed in the adsorption systems of binary and ternary solutions. This is ascribed to the replacement of pre-adsorbed Cu2+ and Cd2+ ions by Pb2+ ions. The ETS-10 column broken up by Pb2+ ions can be regenerated by using an EDTA-Na2 solution and the regenerated column can be reused.

  15. Reduced Effectiveness of Interruptive Drug-Drug Interaction Alerts after Conversion to a Commercial Electronic Health Record.

    PubMed

    Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W

    2018-05-15

    Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.

  16. Simple gas chromatographic system for analysis of microbial respiratory gases

    NASA Technical Reports Server (NTRS)

    Carle, G. C.

    1972-01-01

    Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

  17. High-throughput NGL electron-beam direct-write lithography system

    NASA Astrophysics Data System (ADS)

    Parker, N. William; Brodie, Alan D.; McCoy, John H.

    2000-07-01

    Electron beam lithography systems have historically had low throughput. The only practical solution to this limitation is an approach using many beams writing simultaneously. For single-column multi-beam systems, including projection optics (SCALPELR and PREVAIL) and blanked aperture arrays, throughput and resolution are limited by space-charge effects. Multibeam micro-column (one beam per column) systems are limited by the need for low voltage operation, electrical connection density and fabrication complexities. In this paper, we discuss a new multi-beam concept employing multiple columns each with multiple beams to generate a very large total number of parallel writing beams. This overcomes the limitations of space-charge interactions and low voltage operation. We also discuss a rationale leading to the optimum number of columns and beams per column. Using this approach we show how production throughputs >= 60 wafers per hour can be achieved at CDs

  18. Adaptive Trajectory Prediction Algorithm for Climbing Flights

    NASA Technical Reports Server (NTRS)

    Schultz, Charles Alexander; Thipphavong, David P.; Erzberger, Heinz

    2012-01-01

    Aircraft climb trajectories are difficult to predict, and large errors in these predictions reduce the potential operational benefits of some advanced features for NextGen. The algorithm described in this paper improves climb trajectory prediction accuracy by adjusting trajectory predictions based on observed track data. It utilizes rate-of-climb and airspeed measurements derived from position data to dynamically adjust the aircraft weight modeled for trajectory predictions. In simulations with weight uncertainty, the algorithm is able to adapt to within 3 percent of the actual gross weight within two minutes of the initial adaptation. The root-mean-square of altitude errors for five-minute predictions was reduced by 73 percent. Conflict detection performance also improved, with a 15 percent reduction in missed alerts and a 10 percent reduction in false alerts. In a simulation with climb speed capture intent and weight uncertainty, the algorithm improved climb trajectory prediction accuracy by up to 30 percent and conflict detection performance, reducing missed and false alerts by up to 10 percent.

  19. Early Flood Warning in Africa: Results of a Feasibility study in the JUBA, SHABELLE and ZAMBEZI

    NASA Astrophysics Data System (ADS)

    Pappenberger, F. P.; de Roo, A. D.; Buizza, Roberto; Bodis, Katalin; Thiemig, Vera

    2009-04-01

    Building on the experiences gained with the European Flood Alert System (EFAS), pilot studies are carried out in three river basins in Africa. The European Flood Alert System, pre-operational since 2003, provides early flood alerts for European rivers. At present, the experiences with the European EFAS system are used to evaluate the feasibility of flood early warning for Africa. Three case studies are carried in the Juba and Shabelle rivers (Somalia and Ethiopia), and in the Zambesi river (Southern Africa). Predictions in these data scarce regions are extremely difficult to make as records of observations are scarce and often unreliable. Meteorological and Discharge observations are used to calibrate and test the model, as well as soils, landuse and topographic data available within the JRC African Observatory. ECMWF ERA-40, ERA-Interim data and re-forecasts of flood events from January to March 1978, and in March 2001 are evaluated to examine the feasibility for early flood warning. First results will be presented.

  20. Runway Safety Monitor Algorithm for Runway Incursion Detection and Alerting

    NASA Technical Reports Server (NTRS)

    Green, David F., Jr.; Jones, Denise R. (Technical Monitor)

    2002-01-01

    The Runway Safety Monitor (RSM) is an algorithm for runway incursion detection and alerting that was developed in support of NASA's Runway Incursion Prevention System (RIPS) research conducted under the NASA Aviation Safety Program's Synthetic Vision System element. The RSM algorithm provides pilots with enhanced situational awareness and warnings of runway incursions in sufficient time to take evasive action and avoid accidents during landings, takeoffs, or taxiing on the runway. The RSM currently runs as a component of the NASA Integrated Display System, an experimental avionics software system for terminal area and surface operations. However, the RSM algorithm can be implemented as a separate program to run on any aircraft with traffic data link capability. The report documents the RSM software and describes in detail how RSM performs runway incursion detection and alerting functions for NASA RIPS. The report also describes the RIPS flight tests conducted at the Dallas-Ft Worth International Airport (DFW) during September and October of 2000, and the RSM performance results and lessons learned from those flight tests.

  1. Survey of simulation methods for modeling pulsed sieve-plate extraction columns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burkhart, L.

    1979-03-01

    The report first considers briefly the use of liquid-liquid extraction in nuclear fuel reprocessing and then describes the operation of the pulse column. Currently available simulation models of the column are reviewed, and followed by an analysis of the information presently available from which the necessary parameters can be obtained for use in a model of the column. Finally, overall conclusions are given regarding the information needed to develop an accurate model of the column for materials accountability in fuel reprocessing plants. 156 references.

  2. INITIATE: An Intelligent Adaptive Alert Environment.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza

    2015-01-01

    Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.

  3. Flexible and Accessible Automated Operation of Miniature Chromatography Columns on a Liquid Handling Station.

    PubMed

    Konstantinidis, Spyridon; Goh, Hai-Yuan; Martin Bufájer, José M; de Galbert, Paul; Parau, Maria; Velayudhan, Ajoy

    2018-03-01

    The High Throughput (HT) investigation of chromatographic separations is an important element of downstream bioprocess development due to the importance of chromatography as a technique for achieving stringent regulatory requirements on product purity. Various HT formats for chromatography exist, but the miniature column approach has characteristics resembling large scale packed bed column chromatography the most. The operation of such columns on robotic stations can be automated, but this is not always a straightforward procedure; the robotic manipulations are highly dependent on the settings of each experiment and the standard commands of the supporting software may not provide readily the required flexibility and accessibility for "plug and play" functionality. These can limit the potential of this technique in laboratories engaging on HT activities. In this work, we present an application which aims to overcome this challenge by providing end-users with a flexible operation of the miniature column technique on an automated liquid handler. The application includes a script which is written on Freedom EVOware, and is supplemented by custom compiled executables. Here, the manipulations carried out by the application are described in detail and its functionality is demonstrated through typical experiments based on bind and elute miniature column chromatography. The application is shown to allow for the unsupervised "on-the-fly" programming of the robotic station and to ultimately make the technique accessible to non-automation experts. This application is therefore well suited to simplifying development activities based on the robotic deployment of the miniature column chromatography technique. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Wet snow hazard for power lines: a forecast and alert system applied in Italy

    NASA Astrophysics Data System (ADS)

    Bonelli, P.; Lacavalla, M.; Marcacci, P.; Mariani, G.; Stella, G.

    2011-09-01

    Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly. The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast), developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.

  5. Chemical Safety Alert: Shaft Blow-Out Hazard of Check and Butterfly Valves

    EPA Pesticide Factsheets

    Certain types of check and butterfly valves can undergo shaft-disk separation and fail catastrophically, even when operated within their design limits of pressure and temperature, causing toxic/flammable gas releases, fires, and vapor cloud explosions.

  6. 2B-Alert Web: An Open-Access Tool for Predicting the Effects of Sleep/Wake Schedules and Caffeine Consumption on Neurobehavioral Performance.

    PubMed

    Reifman, Jaques; Kumar, Kamal; Wesensten, Nancy J; Tountas, Nikolaos A; Balkin, Thomas J; Ramakrishnan, Sridhar

    2016-12-01

    Computational tools that predict the effects of daily sleep/wake amounts on neurobehavioral performance are critical components of fatigue management systems, allowing for the identification of periods during which individuals are at increased risk for performance errors. However, none of the existing computational tools is publicly available, and the commercially available tools do not account for the beneficial effects of caffeine on performance, limiting their practical utility. Here, we introduce 2B-Alert Web, an open-access tool for predicting neurobehavioral performance, which accounts for the effects of sleep/wake schedules, time of day, and caffeine consumption, while incorporating the latest scientific findings in sleep restriction, sleep extension, and recovery sleep. We combined our validated Unified Model of Performance and our validated caffeine model to form a single, integrated modeling framework instantiated as a Web-enabled tool. 2B-Alert Web allows users to input daily sleep/wake schedules and caffeine consumption (dosage and time) to obtain group-average predictions of neurobehavioral performance based on psychomotor vigilance tasks. 2B-Alert Web is accessible at: https://2b-alert-web.bhsai.org. The 2B-Alert Web tool allows users to obtain predictions for mean response time, mean reciprocal response time, and number of lapses. The graphing tool allows for simultaneous display of up to seven different sleep/wake and caffeine schedules. The schedules and corresponding predicted outputs can be saved as a Microsoft Excel file; the corresponding plots can be saved as an image file. The schedules and predictions are erased when the user logs off, thereby maintaining privacy and confidentiality. The publicly accessible 2B-Alert Web tool is available for operators, schedulers, and neurobehavioral scientists as well as the general public to determine the impact of any given sleep/wake schedule, caffeine consumption, and time of day on performance of a group of individuals. This evidence-based tool can be used as a decision aid to design effective work schedules, guide the design of future sleep restriction and caffeine studies, and increase public awareness of the effects of sleep amounts, time of day, and caffeine on alertness. © 2016 Associated Professional Sleep Societies, LLC.

  7. Implementation of an Alert and Response System in Haiti during the Early Stage of the Response to the Cholera Epidemic

    PubMed Central

    Santa-Olalla, Patricia; Gayer, Michelle; Magloire, Roc; Barrais, Robert; Valenciano, Marta; Aramburu, Carmen; Poncelet, Jean Luc; Gustavo Alonso, Juan Carlos; Van Alphen, Dana; Heuschen, Florence; Andraghetti, Roberta; Lee, Robert; Drury, Patrick; Aldighieri, Sylvain

    2013-01-01

    The start of the cholera epidemic in Haiti quickly highlighted the necessity of the implementation of an Alert and Response (A&R) System to complement the existing national surveillance system. The national system had been able to detect and confirm the outbreak etiology but required external support to monitor the spread of cholera and coordinate response, because much of the information produced was insufficiently timely for real-time monitoring and directing of a rapid, targeted response. The A&R System was designed by the Pan American Health Organization/World Health Organization in collaboration with the Haiti Ministry of Health, and it was based on a network of partners, including any institution, structure, or individual that could identify, verify, and respond to alerts. The defined objectives were to (1) save lives through early detection and treatment of cases and (2) control the spread through early intervention at the community level. The operational structure could be broken down into three principle categories: (1) alert (early warning), (2) verification and assessment of the information, and (3) efficient and timely response in coordination with partners to avoid duplication. Information generated by the A&R System was analyzed and interpreted, and the qualitative information was critical in qualifying the epidemic and defining vulnerable areas, particularly because the national surveillance system reported incomplete data for more than one department. The A&R System detected a number of alerts unrelated to cholera and facilitated rapid access to that information. The sensitivity of the system and its ability to react quickly was shown in May of 2011, when an abnormal increase in alerts coming from several communes in the Sud-Est Department in epidemiological weeks (EWs) 17 and 18 were noted and disseminated network-wide and response activities were implemented. The national cholera surveillance system did not register the increase until EWs 21 and 22, and the information did not become available until EWs 23 and 24, when the peak of cases had already been reached. Although many of the partners reporting alerts during the peak of the cholera epidemic have since left Haiti, the A&R System has continued to function as an Early Warning (EWARN) System, and it continues to be developed with recent activities, such as the distribution of cell phones to enhance alert communication. PMID:24106196

  8. Implementation of an alert and response system in Haiti during the early stage of the response to the cholera epidemic.

    PubMed

    Santa-Olalla, Patricia; Gayer, Michelle; Magloire, Roc; Barrais, Robert; Valenciano, Marta; Aramburu, Carmen; Poncelet, Jean Luc; Gustavo Alonso, Juan Carlos; Van Alphen, Dana; Heuschen, Florence; Andraghetti, Roberta; Lee, Robert; Drury, Patrick; Aldighieri, Sylvain

    2013-10-01

    The start of the cholera epidemic in Haiti quickly highlighted the necessity of the implementation of an Alert and Response (A&R) System to complement the existing national surveillance system. The national system had been able to detect and confirm the outbreak etiology but required external support to monitor the spread of cholera and coordinate response, because much of the information produced was insufficiently timely for real-time monitoring and directing of a rapid, targeted response. The A&R System was designed by the Pan American Health Organization/World Health Organization in collaboration with the Haiti Ministry of Health, and it was based on a network of partners, including any institution, structure, or individual that could identify, verify, and respond to alerts. The defined objectives were to (1) save lives through early detection and treatment of cases and (2) control the spread through early intervention at the community level. The operational structure could be broken down into three principle categories: (1) alert (early warning), (2) verification and assessment of the information, and (3) efficient and timely response in coordination with partners to avoid duplication. Information generated by the A&R System was analyzed and interpreted, and the qualitative information was critical in qualifying the epidemic and defining vulnerable areas, particularly because the national surveillance system reported incomplete data for more than one department. The A&R System detected a number of alerts unrelated to cholera and facilitated rapid access to that information. The sensitivity of the system and its ability to react quickly was shown in May of 2011, when an abnormal increase in alerts coming from several communes in the Sud-Est Department in epidemiological weeks (EWs) 17 and 18 were noted and disseminated network-wide and response activities were implemented. The national cholera surveillance system did not register the increase until EWs 21 and 22, and the information did not become available until EWs 23 and 24, when the peak of cases had already been reached. Although many of the partners reporting alerts during the peak of the cholera epidemic have since left Haiti, the A&R System has continued to function as an Early Warning (EWARN) System, and it continues to be developed with recent activities, such as the distribution of cell phones to enhance alert communication.

  9. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts.

    PubMed

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M

    2016-04-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. NSI operations center

    NASA Technical Reports Server (NTRS)

    Zanley, Nancy L.

    1991-01-01

    The NASA Science Internet (NSI) Network Operations Staff is responsible for providing reliable communication connectivity for the NASA science community. As the NSI user community expands, so does the demand for greater interoperability with users and resources on other networks (e.g., NSFnet, ESnet), both nationally and internationally. Coupled with the science community's demand for greater access to other resources is the demand for more reliable communication connectivity. Recognizing this, the NASA Science Internet Project Office (NSIPO) expands its Operations activities. By January 1990, Network Operations was equipped with a telephone hotline, and its staff was expanded to six Network Operations Analysts. These six analysts provide 24-hour-a-day, 7-day-a-week coverage to assist site managers with problem determination and resolution. The NSI Operations staff monitors network circuits and their associated routers. In most instances, NSI Operations diagnoses and reports problems before users realize a problem exists. Monitoring of the NSI TCP/IP Network is currently being done with Proteon's Overview monitoring system. The Overview monitoring system displays a map of the NSI network utilizing various colors to indicate the conditions of the components being monitored. Each node or site is polled via the Simple Network Monitoring Protocol (SNMP). If a circuit goes down, Overview alerts the Network Operations staff with an audible alarm and changes the color of the component. When an alert is received, Network Operations personnel immediately verify and diagnose the problem, coordinate repair with other networking service groups, track problems, and document problem and resolution into a trouble ticket data base. NSI Operations offers the NSI science community reliable connectivity by exercising prompt assessment and resolution of network problems.

  11. PEM fuel cell monitoring system

    DOEpatents

    Meltser, M.A.; Grot, S.A.

    1998-06-09

    Method and apparatus are disclosed for monitoring the performance of H{sub 2}--O{sub 2} PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H{sub 2} sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken. 2 figs.

  12. Using clinical simulation centers to test design interventions: a pilot study of lighting and color modifications.

    PubMed

    Gray, Whitney Austin; Kesten, Karen S; Hurst, Stephen; Day, Tama Duffy; Anderko, Laura

    2012-01-01

    The aim of this pilot study was to test design interventions such as lighting, color, and spatial color patterning on nurses' stress, alertness, and satisfaction, and to provide an example of how clinical simulation centers can be used to conduct research. The application of evidence-based design research in healthcare settings requires a transdisciplinary approach. Integrating approaches from multiple fields in real-life settings often proves time consuming and experimentally difficult. However, forums for collaboration such as clinical simulation centers may offer a solution. In these settings, identical operating and patient rooms are used to deliver simulated patient care scenarios using automated mannequins. Two identical rooms were modified in the clinical simulation center. Nurses spent 30 minutes in each room performing simulated cardiac resuscitation. Subjective measures of nurses' stress, alertness, and satisfaction were collected and compared between settings and across time using matched-pair t-test analysis. Nurses reported feeling less stressed after exposure to the experimental room than nurses who were exposed to the control room (2.22, p = .03). Scores post-session indicated a significant reduction in stress and an increase in alertness after exposure to the experimental room as compared to the control room, with significance levels below .10. (Change in stress scores: 3.44, p = .069); (change in alertness scores: 3.6, p = .071). This study reinforces the use of validated survey tools to measure stress, alertness, and satisfaction. Results support human-centered design approaches by evaluating the effect on nurses in an experimental setting.

  13. The French Infectious Diseases Society's readiness and response to epidemic or biological risk-the current situation following the Middle East respiratory syndrome coronavirus and Ebola virus disease alerts.

    PubMed

    Coignard-Biehler, H; Rapp, C; Chapplain, J M; Hoen, B; Che, D; Berthelot, P; Cazenave-Roblot, F; Rabaud, C; Brouqui, P; Leport, C

    2018-03-01

    In 2012, the French Infectious Diseases Society (French acronym SPILF) initiated the "Coordination of epidemic and biological risk" (SPILF-COREB - Emergences [SCE]) group to support the readiness and response of healthcare workers (HCWs) to new alerts. To present the SCE group, its functioning, and the main support it provided for frontline HCWs. A multidisciplinary group of heads of infectious disease departments from reference hospitals was created to build a network of clinical expertise for care, training, and research in the field of epidemic and biological risk (EBR). The network developed a set of standardized operational procedures (SOPs) to guide interventions to manage EBR-suspect patients. A working group created the SOP aimed at frontline HCWs taking care of patients. Priority was given to the development of a generic procedure, which was then adapted according to the current alert. Five key steps were identified and hierarchized: detecting, protecting, caring for, alerting, and referring the EBR patient. The interaction between clinicians and those responsible for the protection of the community was crucial. The SOPs validated by the SPILF and its affiliates were disseminated to a wide range of key stakeholders through various media including workshops and the SPILF's website. SPILF can easily adapt and timely mobilize the EBR expertise in case of an alert. The present work suggests that sharing and discussing this experience, initiated at the European level, can generate a new collective expertise and needs to be further developed and strengthened. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Enantioseparation of racemic aminoglutethimide using asynchronous simulated moving bed chromatography.

    PubMed

    Lin, Xiaojian; Gong, Rujin; Li, Jiaxu; Li, Ping; Yu, Jianguo; Rodrigues, Alirio E

    2016-10-07

    The separation of aminoglutethimide enantiomers by the continuous multicolumn chromatographic processes were investigated experimentally and theoretically, where the columns were packed with cellulose tris 3,5-dimethylphenyl-carbamate stationary phase (brand name Chiralcel OD) and mobile phase was a mixture of n-hexane and ethanol with monoethanolamine additive. The continuous enantioseparation processes included a synchronous shifting process (SMB) and an asynchronous shifting process (VARICOL), which allowed reducing the column number (here from six-column SMB to five-column VARICOL process). Transport-dispersive model with the consideration of both intraparticle mass transfer resistance and axial dispersion was adopted to design and optimize the operation conditions for the separation of aminoglutethimide enantiomers by SMB process and VARICOL process. According to the optimized operation conditions, experiments were carried out on VARICOL-Micro unit using five-column VARICOL process with 1/1.5/1.5/1 configuration and six-column SMB process with 1/2/2/1 configuration. Products of R-aminoglutethimide (R-AG) enantiomer and S-aminoglutethimide (S-AG) enantiomer with more than 99.0% purity were obtained continuously from extract stream and raffinate stream, respectively. Furthermore, the experiemntal data obtained from five-column VARICOL process were compared with that from six-column SMB process, the feasibility and efficiency for the separation of guaifenesin enantiomers by VARICOL processes were evaluated. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Global walks teach teens to fight HIV/AIDS epidemic. Organization supported entirely by volunteers.

    PubMed

    Chittick, John

    2002-09-01

    AIDS Alert asked John Chittick, EdD, executive director of TeenAIDS-PeerCorps Inc., a nonprofit organization in Boston, to discuss the global walks he founded and an abstract he presented at the 14th International AIDS Conference in Barcelona, Spain. According to the abstract, global walks began in 1999 with Chittick spreading the word by foot about HIV/AIDS in 40 countries to teen volunteers, who, in turn, were expected to educate their peers about HIV prevention. Within two years, the global walk had reached 75,000 youth, who taught HIV prevention through such techniques as Stop Action Theater, street outreach 'AIDS Attacks,' and 'AIDS Comics,' which were drawn by teens. Also, there is a Teen Advice Column available in multiple languages on the Internet.

  16. The Objective of Financial Reporting.

    ERIC Educational Resources Information Center

    Schermann, Kenneth R.

    1986-01-01

    Alerts public school business officials to a financial reporting concepts statement to be issued by the Governmental Accounting Standards Board in late 1986. The new directive will outline four objectives concerned with accountability procedures, resource management and compliance information, operating results, and future financial capabilities.…

  17. Process Security in Chemical Engineering Education

    ERIC Educational Resources Information Center

    Piluso, Cristina; Uygun, Korkut; Huang, Yinlun; Lou, Helen H.

    2005-01-01

    The threats of terrorism have greatly alerted the chemical process industries to assure plant security at all levels: infrastructure-improvement-focused physical security, information-protection-focused cyber security, and design-and-operation-improvement-focused process security. While developing effective plant security methods and technologies…

  18. Auditory Information Systems in Military Aircraft: Current Configurations Versus the State of the Art.

    DTIC Science & Technology

    1984-06-01

    types of conditions, discriminable differences in intensity, pitch, or use of beats or harmonics shall be provided. If absolute discrimination is...shall be directed to the operator’s headset as well as to the work area. Binaural headsets should not be used in any operational environment below 85...signals are to be used to alert an operator to different types of conditions, discriminable difference in Intensity, pitch, or use of beats and harmonics

  19. Safety management of a complex R and D ground operating system

    NASA Technical Reports Server (NTRS)

    Connors, J. F.; Maurer, R. A.

    1975-01-01

    A perspective on safety program management was developed for a complex R&D operating system, such as the NASA-Lewis Research Center. Using a systems approach, hazardous operations are subjected to third-party reviews by designated-area safety committees and are maintained under safety permit controls. To insure personnel alertness, emergency containment forces and employees are trained in dry-run emergency simulation exercises. The keys to real safety effectiveness are top management support and visibility of residual risks.

  20. Safety management of a complex R&D ground operating system

    NASA Technical Reports Server (NTRS)

    Connors, J. F.; Maurer, R. A.

    1975-01-01

    A perspective on safety program management has been developed for a complex R&D operating system, such as the NASA-Lewis Research Center. Using a systems approach, hazardous operations are subjected to third-party reviews by designated area safety committees and are maintained under safety permit controls. To insure personnel alertness, emergency containment forces and employees are trained in dry-run emergency simulation exercises. The keys to real safety effectiveness are top management support and visibility of residual risks.

  1. AMON: Transition to real-time operations

    NASA Astrophysics Data System (ADS)

    Cowen, D. F.; Keivani, A.; Tešić, G.

    2016-04-01

    The Astrophysical Multimessenger Observatory Network (AMON) will link the world's leading high-energy neutrino, cosmic-ray, gamma-ray and gravitational wave observatories by performing real-time coincidence searches for multimessenger sources from observatories' subthreshold data streams. The resulting coincidences will be distributed to interested parties in the form of electronic alerts for real-time follow-up observation. We will present the science case, design elements, current and projected partner observatories, status of the AMON project, and an initial AMON-enabled analysis. The prototype of the AMON server has been online since August 2014 and processing archival data. Currently, we are deploying new high-uptime servers and will be ready to start issuing alerts as early as winter 2015/16.

  2. Runway Incursion Prevention System Simulation Evaluation

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.

    2002-01-01

    A Runway Incursion Prevention System (RIPS) was evaluated in a full mission simulation study at the NASA Langley Research center in March 2002. RIPS integrates airborne and ground-based technologies to provide (1) enhanced surface situational awareness to avoid blunders and (2) alerts of runway conflicts in order to prevent runway incidents while also improving operational capability. A series of test runs was conducted in a high fidelity simulator. The purpose of the study was to evaluate the RIPS airborne incursion detection algorithms and associated alerting and airport surface display concepts. Eight commercial airline crews participated as test subjects completing 467 test runs. This paper gives an overview of the RIPS, simulation study, and test results.

  3. Quantitative precipitation forecasts in the Alps - an assessment from the Forecast Demonstration Project MAP D-PHASE

    NASA Astrophysics Data System (ADS)

    Ament, F.; Weusthoff, T.; Arpagaus, M.; Rotach, M.

    2009-04-01

    The main aim of the WWRP Forecast Demonstration Project MAP D-PHASE is to demonstrate the performance of today's models to forecast heavy precipitation and flood events in the Alpine region. Therefore an end-to-end, real-time forecasting system was installed and operated during the D PHASE Operations Period from June to November 2007. Part of this system are 30 numerical weather prediction models (deterministic as well as ensemble systems) operated by weather services and research institutes, which issue alerts if predicted precipitation accumulations exceed critical thresholds. Additionally to the real-time alerts, all relevant model fields of these simulations are stored in a central data archive. This comprehensive data set allows a detailed assessment of today's quantitative precipitation forecast (QPF) performance in the Alpine region. We will present results of QPF verifications against Swiss radar and rain gauge data both from a qualitative point of view, in terms of alerts, as well as from a quantitative perspective, in terms of precipitation rate. Various influencing factors like lead time, accumulation time, selection of warning thresholds, or bias corrections will be discussed. Additional to traditional verifications of area average precipitation amounts, the performance of the models to predict the correct precipitation statistics without requiring a point-to-point match will be described by using modern Fuzzy verification techniques. Both analyses reveal significant advantages of deep convection resolving models compared to coarser models with parameterized convection. An intercomparison of the model forecasts themselves reveals a remarkably high variability between different models, and makes it worthwhile to evaluate the potential of a multi-model ensemble. Various multi-model ensemble strategies will be tested by combining D-PHASE models to virtual ensemble systems.

  4. Operational Implementation of Space Debris Mitigation Procedures

    NASA Astrophysics Data System (ADS)

    Gicquel, Anne-Helene; Bonaventure, Francois

    2013-08-01

    During the spacecraft lifetime, Astrium supports its customers to manage collision risks alerts from the Joint Space Operations Center (JSpOC). This was previously done with hot-line support and a manual operational procedure. Today, it is automated and integrated in QUARTZ, the Astrium Flight Dynamics operational tool. The algorithms and process details for this new 5- step functionality are provided in this paper. To improve this functionality, some R&D activities such as the study of dilution phenomenon and low relative velocity encounters are going on. Regarding end of life disposal, recent operational experiences as well as studies results are presented.

  5. Advanced alerting features: displaying new relevant data and retracting alerts.

    PubMed Central

    Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.

    1997-01-01

    We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625

  6. A Cognitive System Model for Human/Automation Dynamics in Airspace Management

    NASA Technical Reports Server (NTRS)

    Corker, Kevin M.; Pisanich, Gregory; Lebacqz, J. Victor (Technical Monitor)

    1997-01-01

    NASA has initiated a significant thrust of research and development focused on providing the flight crew and air traffic managers automation aids to increase capacity in en route and terminal area operations through the use of flexible, more fuel-efficient routing, while improving the level of safety in commercial carrier operations. In that system development, definition of cognitive requirements for integrated multi-operator dynamic aiding systems is fundamental. In order to support that cognitive function definition, we have extended the Man Machine Integrated Design and Analysis System (MIDAS) to include representation of multiple cognitive agents (both human operators and intelligent aiding systems) operating aircraft, airline operations centers and air traffic control centers in the evolving airspace. The demands of this application require representation of many intelligent agents sharing world-models, and coordinating action/intention with cooperative scheduling of goals and actions in a potentially unpredictable world of operations. The MIDAS operator models have undergone significant development in order to understand the requirements for operator aiding and the impact of that aiding in the complex nondeterminate system of national airspace operations. The operator model's structure has been modified to include attention functions, action priority, and situation assessment. The cognitive function model has been expanded to include working memory operations including retrieval from long-term store, interference, visual-motor and verbal articulatory loop functions, and time-based losses. The operator's activity structures have been developed to include prioritization and interruption of multiple parallel activities among multiple operators, to provide for anticipation (knowledge of the intention and action of remote operators), and to respond to failures of the system and other operators in the system in situation-specific paradigms. The model's internal representation has been be modified so that multiple, autonomous sets of equipment will function in a scenario as the single equipment sets do now. In order to support the analysis requirements with multiple items of equipment, it is necessary for equipment to access the state of other equipment objects at initialization time (a radar object may need to access the position and speed of aircraft in its area, for example), and as a function of perception and sensor system interaction. The model has been improved to include multiple world-states as a function of equipment am operator interaction. The model has been used -1o predict the impact of warning and alert zones in aircraft operation, and, more critic-ally, the interaction of flight-deck based warning mechanisms and air traffic controller action in response to ground-based conflict prediction and alerting systems. In this operation, two operating systems provide alerting to two autonomous, but linked sets of operators, whose view of the system and whose dynamics in response are radically different. System stability and operator action was predicted using the MIDAS model.

  7. Use of laterite for the removal of fluoride from contaminated drinking water.

    PubMed

    Sarkar, Mitali; Banerjee, Aparna; Pramanick, Partha Pratim; Sarkar, Asit R

    2006-10-15

    The effects of different operational variables on the mechanistic function of laterite in removal of fluoride have been investigated. Thermodynamic parameters such as free energy change, enthalpy, and entropy of the process, as well as the sorption isotherm, were evaluated. The extent of solute removal is determined by initial solute concentration, operational conditions, laterite dose, and solution pH. For a fixed set of experimental conditions, a model equation is developed from which the percent removal corresponding to each load of fluoride is determined. The mechanism of fluoride adsorption is governed by the zero point charge of laterite and follows a first-order rate equation. pH has a vital role influencing the surface characteristics of laterite. To simulate the flow dynamics, fluoride solution was run through a fixed bed column. The pattern of breakthrough curves for different influent fluoride concentration, pH, and column bed height was characterized. The column efficiency was tested from the bed depth-service time model. The elution of the retained fluoride was studied and the effectiveness of column operation was determined by the retention-elution cycles.

  8. Citizen earthquake alert using near real time PGA estimation from a local array combining a variety of accelerometric instruments

    NASA Astrophysics Data System (ADS)

    Melis, Nikolaos S.; Konstantinou, Konstantinos; Kalogeras, Ioannis; Sokos, Efthimios; Tselentis, G.-Akis

    2017-04-01

    It is of a great importance to assess rapidly the intensity of a felt event in a highly populated environment. Rapid and reliable information plays a key role to decision making responses, by performing correctly the first steps after a felt ground shaking. Thus, it is important to accurately respond to urgent societal demand using reliable information. A strong motion array is under deployment and trial operation in the area of Patras, Greece. It combines: (a) standard accelerometric stations operated by the National Observatory of Athens, Institute of Geodynamics (NOA), (b) QCN-type USB MEMS acceleration sensors deployed in schools and (c) P-alert MEMS acceleration devices deployed in public sector buildings as well as in private dwellings. The array intends to cover the whole city of Patras and the populated suburbs. All instruments are operating in near real time and they are linked to a combined Earthworm - SeisComP3 server at NOA, Athens. Rapid intensity estimation can be also performed by the P-alert accelerometers locally, but the performance of a near real time intensity estimation system is under operation at NOA. The procedure is based on observing the maximum PGA value at each instrument and empirically estimate the corresponding intensity. The values are also fed to a SeisComP3 based ShakeMap procedure that is served at NOA and uses the scwfparam module of SeisComP3. Earthquake activity has been recorded so far from the western Corinth Gulf, the Ionian Islands and Achaia-Elia area, western Peloponnesus. The first phase involves correlation tests of collocated instruments and assessment of their performance to low intensity as well as to strongly felt events in the Patras city area. Steps of expanding the array are also under consideration, in order to cover the wider area of northwestern Peloponnesus and Ionian islands.

  9. Technologic Distractions (Part 1): Summary of Approaches to Manage Alert Quantity With Intent to Reduce Alert Fatigue and Suggestions for Alert Fatigue Metrics.

    PubMed

    Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D

    2017-09-01

    To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.

  10. DARK Technology Transition Plan

    DTIC Science & Technology

    1990-04-01

    or suspend/resume primitives , and bounded delays. Under the above circumstances, the extra language features, and the hidden system calls they... system , this implies that the mechanisms by which units interact - to synchronise , communicate, schedule one another, or alert one another - should be...the Kernel environment are: " The host system is a DEC VAX operating under VMS 5.0 (the specific host used at the SEI is a MicroVAX II operating under

  11. Eye Metrics: An Alternative Vigilance Detector for Military Cyber Operators

    DTIC Science & Technology

    2013-10-01

    cyber operator task. The significant change of oculometric measurements indicates that oculometrics could be used to detect changes in sustained...a significant change over time (p<.05) during the vigilance task. The significant change of oculometric measurements indicates that oculometrics...percentage of eye closure); it is the most widely used measure of real-time alertness in this industry (Dinges & Grace, 1998; Mallis et al., 1999

  12. Pressure, temperature and density drops along supercritical fluid chromatography columns. I. Experimental results for neat carbon dioxide and columns packed with 3- and 5-micron particles.

    PubMed

    Poe, Donald P; Veit, Devon; Ranger, Megan; Kaczmarski, Krzysztof; Tarafder, Abhijit; Guiochon, Georges

    2012-08-10

    The pressure drop and temperature drop on columns packed with 3- and 5-micron particles were measured using neat CO(2) at a flow rate of 5 mL/min, at temperatures from 20°C to 100°C, and outlet pressures from 80 to 300 bar. The density drop was calculated based on the temperature and pressure at the column inlet and outlet. The columns were suspended in a circulating air bath either bare or covered with foam insulation. The results show that the pressure drop depends on the outlet pressure, the operating temperature, and the thermal environment. A temperature drop was observed for all conditions studied. The temperature drop was relatively small (less than 3°C) for combinations of low temperature and high pressure. Larger temperature drops and density drops occurred at higher temperatures and low to moderate pressures. Covering the column with thermal insulation resulted in larger temperature drops and corresponding smaller density drops. At 20°C the temperature drop was never more than a few degrees. The largest temperature drops occurred for both columns when insulated at 80°C and 80 bar, reaching a maximum value of 21°C for the 5-micron column, and 26°C for the 3-micron column. For an adiabatic column, the temperature drop depends on the pressure drop, the thermal expansion coefficient, and the density and the heat capacity of the mobile phase fluid, and can be described by a simple mathematical relationship. For a fixed operating temperature and outlet pressure, the temperature drop increases monotonically with the pressure drop. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Baiting Inside Attackers using Decoy Documents

    DTIC Science & Technology

    2008-09-16

    viewed. Animated images allow the senders to monitor how long the message was displayed. The web bugs operate without alerting the user of the...Military Computer Security Policies”. IEEE Symposium on Security and Privacy, 1987. [5] Demers, A., Gehrke, J., Hong, M., Panda , B., Riedewald, M., Sharma

  14. Head Mounted Alerting for Urban Operations via Tactical Information Management System

    DTIC Science & Technology

    2006-03-01

    MOUT Area Based Experiments .......................................................................... 62 6.4.2 Video Game Based Experiments...associated with the video game task. ................................................................ 35 Figure 20: The learning rate for truth sets defined...23 Table 6: Results of experiments from Breakthrough Mission for our Video Game Configuration

  15. Improving the effectiveness of nighttime temporary traffic control warning devices, volume 2 : evaluation of nighttime mobile warning lights.

    DOT National Transportation Integrated Search

    2013-11-01

    Vehicle-mounted warning lights for nighttime mobile highway operations provide critical protection to workers and the driving : public. Alerting the traveling public of the approaching work activity and providing guidance is vital to maintaining safe...

  16. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  17. A framework for evaluating the appropriateness of clinical decision support alerts and responses

    PubMed Central

    Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F

    2011-01-01

    Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334

  18. Medication-related clinical decision support alert overrides in inpatients.

    PubMed

    Nanji, Karen C; Seger, Diane L; Slight, Sarah P; Amato, Mary G; Beeler, Patrick E; Her, Qoua L; Dalleur, Olivia; Eguale, Tewodros; Wong, Adrian; Silvers, Elizabeth R; Swerdloff, Michael; Hussain, Salman T; Maniam, Nivethietha; Fiskio, Julie M; Dykes, Patricia C; Bates, David W

    2018-05-01

    To define the types and numbers of inpatient clinical decision support alerts, measure the frequency with which they are overridden, and describe providers' reasons for overriding them and the appropriateness of those reasons. We conducted a cross-sectional study of medication-related clinical decision support alerts over a 3-year period at a 793-bed tertiary-care teaching institution. We measured the rate of alert overrides, the rate of overrides by alert type, the reasons cited for overrides, and the appropriateness of those reasons. Overall, 73.3% of patient allergy, drug-drug interaction, and duplicate drug alerts were overridden, though the rate of overrides varied by alert type (P < .0001). About 60% of overrides were appropriate, and that proportion also varied by alert type (P < .0001). Few overrides of renal- (2.2%) or age-based (26.4%) medication substitutions were appropriate, while most duplicate drug (98%), patient allergy (96.5%), and formulary substitution (82.5%) alerts were appropriate. Despite warnings of potential significant harm, certain categories of alert overrides were inappropriate >75% of the time. The vast majority of duplicate drug, patient allergy, and formulary substitution alerts were appropriate, suggesting that these categories of alerts might be good targets for refinement to reduce alert fatigue. Almost three-quarters of alerts were overridden, and 40% of the overrides were not appropriate. Future research should optimize alert types and frequencies to increase their clinical relevance, reducing alert fatigue so that important alerts are not inappropriately overridden.

  19. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    PubMed Central

    Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.

    2017-01-01

    Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887

  20. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.

    PubMed

    Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2017-01-01

    Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N  = 148) and 51% ( N  = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N  = 5) and median 2 min ( N  = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.

  1. JPL's GNSS Real-Time Earthquake and Tsunami (GREAT) Alert System

    NASA Astrophysics Data System (ADS)

    Bar-Sever, Yoaz; Miller, Mark; Vallisneri, Michele; Khachikyan, Robert; Meyer, Robert

    2017-04-01

    We describe recent developments to the GREAT Alert natural hazard monitoring service from JPL's Global Differential GPS (GDGPS) System. GREAT Alert provides real-time, 1 Hz positioning solutions for hundreds of GNSS tracking sites, from both global and regional networks, aiming to monitor ground motion in the immediate aftermath of earthquakes. We take advantage of the centralized data processing, which is collocated with the GNSS orbit determination operations of the GDGPS System, to combine orbit determination with large-scale point-positioning in a grand estimation scheme, and as a result realize significant improvement to the positioning accuracy compared to conventional stand-alone point positioning techniques. For example, the measured median site (over all sites) real-time horizontal positioning accuracy is 2 cm 1DRMS, and the median real-time vertical accuracy is 4 cm RMS. The GREAT Alert positioning service is integrated with automated global earthquake notices from the United States Geodetic Survey (USGS) to support near-real-time calculations of co-seismic displacements with attendant formal errors based both short-term and long-term error analysis for each individual site. We will show the millimeter-level resolution of co-seismic displacement can be achieved by this system. The co-seismic displacements, in turn, are fed into a JPL geodynamics and ocean models, that estimate the Earthquake magnitude and predict the potential tsunami scale.

  2. IP telephony based danger alert communication system and its implementation

    NASA Astrophysics Data System (ADS)

    Rezac, Filip; Safarik, Jakub; Voznak, Miroslav; Tomala, Karel; Partila, Pavol

    2013-05-01

    This article discusses a danger alert system created as a part of the research project at Department of Telecommunications of Technical University of Ostrava. The aim of the system is to distribute pre-recorded voice messages in order to alert the called party in danger. This article describes individual technologies, which the application uses for its operation as well as issues relating to hardware requirements and transfer line bandwidth load. The article also describes new algorithms, which had to be developed in order to ensure the reliability of the system. Our intent is focused on disaster management, the message, which should be delivered within specified time span, is typed in the application and text-to-speech module ensures its transformation to a speech format, after that a particular scenario or warned area is selected and a target group is automatically unloaded. For this purpose, we have defined XML format for delivery of phone numbers which are located in the target area and these numbers are obtained from mobile BTS's (Base transmission stations). The benefit of such communication compared to others, is the fact, that it uses a phone call and, therefore, it is possible to get feedback who accepted the message and to improve efficiency of alert system. Finally, the list of unanswered calls is exported and these users can be informed via SMS.

  3. Decoding and optimized implementation of SECDED codes over GF(q)

    DOEpatents

    Ward, H. Lee; Ganti, Anand; Resnick, David R

    2013-10-22

    A plurality of columns for a check matrix that implements a distance d linear error correcting code are populated by providing a set of vectors from which to populate the columns, and applying to the set of vectors a filter operation that reduces the set by eliminating therefrom all vectors that would, if used to populate the columns, prevent the check matrix from satisfying a column-wise linear independence requirement associated with check matrices of distance d linear codes. One of the vectors from the reduced set may then be selected to populate one of the columns. The filtering and selecting repeats iteratively until either all of the columns are populated or the number of currently unpopulated columns exceeds the number of vectors in the reduced set. Columns for the check matrix may be processed to reduce the amount of logic needed to implement the check matrix in circuit logic.

  4. Design, decoding and optimized implementation of SECDED codes over GF(q)

    DOEpatents

    Ward, H Lee; Ganti, Anand; Resnick, David R

    2014-06-17

    A plurality of columns for a check matrix that implements a distance d linear error correcting code are populated by providing a set of vectors from which to populate the columns, and applying to the set of vectors a filter operation that reduces the set by eliminating therefrom all vectors that would, if used to populate the columns, prevent the check matrix from satisfying a column-wise linear independence requirement associated with check matrices of distance d linear codes. One of the vectors from the reduced set may then be selected to populate one of the columns. The filtering and selecting repeats iteratively until either all of the columns are populated or the number of currently unpopulated columns exceeds the number of vectors in the reduced set. Columns for the check matrix may be processed to reduce the amount of logic needed to implement the check matrix in circuit logic.

  5. Decoding and optimized implementation of SECDED codes over GF(q)

    DOEpatents

    Ward, H Lee; Ganti, Anand; Resnick, David R

    2014-11-18

    A plurality of columns for a check matrix that implements a distance d linear error correcting code are populated by providing a set of vectors from which to populate the columns, and applying to the set of vectors a filter operation that reduces the set by eliminating therefrom all vectors that would, if used to populate the columns, prevent the check matrix from satisfying a column-wise linear independence requirement associated with check matrices of distance d linear codes. One of the vectors from the reduced set may then be selected to populate one of the columns. The filtering and selecting repeats iteratively until either all of the columns are populated or the number of currently unpopulated columns exceeds the number of vectors in the reduced set. Columns for the check matrix may be processed to reduce the amount of logic needed to implement the check matrix in circuit logic.

  6. Physicians’ response to computerised alerts for psychotropic drugs in older persons: a multilevel analysis of the associated alert, patient and physician characteristics

    PubMed Central

    Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali

    2012-01-01

    Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID:23024254

  7. Assessing the Applicability of Earthquake Early Warning in Nicaragua.

    NASA Astrophysics Data System (ADS)

    Massin, F.; Clinton, J. F.; Behr, Y.; Strauch, W.; Cauzzi, C.; Boese, M.; Talavera, E.; Tenorio, V.; Ramirez, J.

    2016-12-01

    Nicaragua, like much of Central America, suffers from frequent damaging earthquakes (6 M7+ earthquakes occurred in the last 100 years). Thrust events occur at the Middle America Trench where the Cocos plate subducts by 72-81 mm/yr eastward beneath the Caribbean plate. Shallow crustal events occur on-shore, with potential extensive damage as demonstrated in 1972 by a M6.2 earthquake, 5 km beneath Managua. This seismotectonic setting is challenging for Earthquake Early Warning (EEW) because the target events derive from both the offshore seismicity, with potentially large lead times but uncertain locations, and shallow seismicity in close proximity to densely urbanized areas, where an early warning would be short if available at all. Nevertheless, EEW could reduce Nicaragua's earthquake exposure. The Swiss Development and Cooperation Fund and the Nicaraguan Government have funded a collaboration between the Swiss Seismological Service (SED) at ETH Zurich and the Nicaraguan Geosciences Institute (INETER) in Managua to investigate and build a prototype EEW system for Nicaragua and the wider region. In this contribution, we present the potential of EEW to effectively alert Nicaragua and the neighbouring regions. We model alert time delays using all available seismic stations (existing and planned) in the region, as well as communication and processing delays (observed and optimal) to estimate current and potential performances of EEW alerts. Theoretical results are verified with the output from the Virtual Seismologist in SeisComP3 (VS(SC3)). VS(SC3) is implemented in the INETER SeisComP3 system for real-time operation and as an offline instance, that simulates real-time operation, to record processing delays of playback events. We compare our results with similar studies for Europe, California and New Zealand. We further highlight current capabilities and challenges for providing EEW alerts in Nicaragua. We also discuss how combining different algorithms, like e.g. VS and FinDer, can lead to a robust approach to EEW.

  8. Differential effects of phasic and tonic alerting on the efficiency of executive attention.

    PubMed

    Asanowicz, Dariusz; Marzecová, Anna

    2017-05-01

    The study examined how alerting and executive attention interact in a task involving conflict resolution. We proposed a tentative scenario in which an initial exogenous phasic alerting phase is followed by an endogenous tonic alerting phase, and hypothesized that these two processes may have distinct effects on conflict resolution. Phasic alerting was expected to increase the conflict, whereas tonic alerting was expected to decrease the conflict. Three experiments were conducted using different variants of the flanker task with visual alerting cues and varied cue-target intervals (SOA), to differentiate between effects of phasic alerting (short SOA) and tonic alerting (long SOA). The results showed that phasic alerting consistently decreased the efficiency of conflict resolution indexed by response time and accuracy, whereas tonic alerting increased the accuracy of conflict resolution, but at a cost in the speed of processing the conflict. The third experiment additionally showed that the effects of phasic alerting may be modulated by the psychophysical strength of alerting cues. Discussed are possible mechanisms that could account for the observed interactions between alerting and conflict resolution, as well as some discrepancies between the current and previous studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. CANOZE measurements of the Arctic ozone hole

    NASA Technical Reports Server (NTRS)

    Evans, W. F. J.; Kerr, J. B.; Fast, H.

    1988-01-01

    In CANOZE 1 (Canadian Ozone Experiment), a series of 20 ozone profile measurements were made in April, 1986 from Alert at 82.5 N. CANOZE is the Canadian program for study of the Arctic winter ozone layer. In CANOZE 2, ozone profile measurements were made at Saskatoon, Edmonton, Churchill and Resolute during February and March, 1987 with ECC ozonesondes. Ground based measurements of column ozone, nitrogen dioxide and hydrochloric acid were conducted at Saskatoon. Two STRATOPROBE balloon flights were conducted on February 26 and March 19, 1987. Two aerosol flights were conducted by the University of Wyoming. The overall results of this study will be reported and compared with the NOZE findings. The results from CANOZE 3 in 1988, are also discussed. In 1988, as part of CANOZE 3, STRATOPROBE balloon flights were conducted from Saskatchewan on January 27 and February 13. A new lightweight infrared instrument was developed and test flown. A science flight was successfully conducted from Alert (82.5 N) on March 9, 1988 when the vortex was close to Alert; a good measurement of the profile of nitric acid was obtained. Overall, the Arctic spring ozone layer exhibits many of the features of the Antarctic ozone phenomenon, although there is obviously not a hole present every year. The Arctic ozone field in March, 1986 demonstrated many similarities to the Antarctic ozone hole. The TOMS imagery showed a crater structure in the ozone field similar to the Antarctic crater in October. Depleted layers of ozone were found in the profiles around 15 km, very similar to those reported from McMurdo. Enhanced levels of nitric acid were measured in air which had earlier been in the vortex. The TOMS imagery for March 1987 did not show an ozone crater, but will be examined for an ozone crater in February and March, 1988, the target date for the CANOZE 3 project.

  10. Future Earth: Reducing Loss By Automating Response to Earthquake Shaking

    NASA Astrophysics Data System (ADS)

    Allen, R. M.

    2014-12-01

    Earthquakes pose a significant threat to society in the U.S. and around the world. The risk is easily forgotten given the infrequent recurrence of major damaging events, yet the likelihood of a major earthquake in California in the next 30 years is greater than 99%. As our societal infrastructure becomes ever more interconnected, the potential impacts of these future events are difficult to predict. Yet, the same inter-connected infrastructure also allows us to rapidly detect earthquakes as they begin, and provide seconds, tens or seconds, or a few minutes warning. A demonstration earthquake early warning system is now operating in California and is being expanded to the west coast (www.ShakeAlert.org). In recent earthquakes in the Los Angeles region, alerts were generated that could have provided warning to the vast majority of Los Angelinos who experienced the shaking. Efforts are underway to build a public system. Smartphone technology will be used not only to issue that alerts, but could also be used to collect data, and improve the warnings. The MyShake project at UC Berkeley is currently testing an app that attempts to turn millions of smartphones into earthquake-detectors. As our development of the technology continues, we can anticipate ever-more automated response to earthquake alerts. Already, the BART system in the San Francisco Bay Area automatically stops trains based on the alerts. In the future, elevators will stop, machinery will pause, hazardous materials will be isolated, and self-driving cars will pull-over to the side of the road. In this presentation we will review the current status of the earthquake early warning system in the US. We will illustrate how smartphones can contribute to the system. Finally, we will review applications of the information to reduce future losses.

  11. Evaluating Fatigue in Operational Settings: The NASA Ames Fatigue Countermeasures Program

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Gregory, Kevin; Miller, Donna; Webbon, Lissa; Oyung, Ray

    1996-01-01

    In response to a 1980 Congressional request, NASA Ames initiated a program to examine fatigue in flight operations. The Program objectives are to examine fatigue, sleep loss, and circadian disruption in flight operations, determine the effects of these factors on flight crew performance, and the development of fatigue countermeasures. The NASA Ames Fatigue Countermeasures Program conducts controlled laboratory experiments, full-mission flight simulations, and field studies. A range of subjective, behavioral, performance, physiological, and environmental measures are used depending on study objectives. The Program has developed substantial expertise in gathering data during actual flight operations and in other work settings. This has required the development of ambulatory and other measures that can be carried throughout the world and used at 41,000 feet in aircraft cockpits. The NASA Ames Fatigue Countermeasures Program has examined fatigue in shorthaul, longhaul, overnight cargo, and helicopter operations. A recent study of planned cockpit rest periods demonstrated the effectiveness of a brief inflight nap to improve pilot performance and alertness. This study involved inflight reaction time/vigilance performance testing and EEG/EOG measures of physiological alertness. The NASA Ames Fatigue Countermeasures Program has applied scientific findings to the development of education and training materials on fatigue countermeasures, input to federal regulatory activities on pilot flight, duty, and rest requirements, and support of National Transportation Safety Board accident investigations. Current activities are examining fatigue in nonaugmented longhaul flights, regional/commuter flight operations, corporate/business aviation, and psychophysiological variables related to performance.

  12. Evaluation of health alerts from an early illness warning system in independent living.

    PubMed

    Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica

    2013-06-01

    Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.

  13. A Comprehensive Laboratory Animal Facility Pandemic Response Plan

    PubMed Central

    Roble, Gordon S; Lingenhol, Naomi M; Baker, Bryan; Wilkerson, Amy; Tolwani, Ravi J

    2010-01-01

    The potential of a severe influenza pandemic necessitates the development of an organized, rational plan for continued laboratory animal facility operation without compromise of the welfare of animals. A comprehensive laboratory animal program pandemic response plan was integrated into a university-wide plan. Preparation involved input from all levels of organizational hierarchy including the IACUC. Many contingencies and operational scenarios were considered based on the severity and duration of the influenza pandemic. Trigger points for systematic action steps were based on the World Health Organization's phase alert criteria. One extreme scenario requires hibernation of research operations and maintenance of reduced numbers of laboratory animal colonies for a period of up to 6 mo. This plan includes active recruitment and cross-training of volunteers for essential personnel positions, protective measures for employee and family health, logistical arrangements for delivery and storage of food and bedding, the removal of waste, and the potential for euthanasia. Strategies such as encouraging and subsidizing cryopreservation of unique strains were undertaken to protect valuable research assets and intellectual property. Elements of this plan were put into practice after escalation of the pandemic alerts due to influenza A (H1N1) in April 2009. PMID:20858365

  14. Detection of Oil in Water Column: Sensor Design

    DTIC Science & Technology

    2013-02-01

    rivers , and initiating dispersant application or oil recovery operations. Challenges in detecting oil within the water column include poor...facility and along transects in the Delaware River . However, all readings were at background, even when there was visible oil on the water surface...levels for extremely high CDOM rich rivers . Detection of Oil in Water Column: Sensor Design 14 UNCLAS//Public | CG-926 RDC | Fitzpatrick, et al

  15. An IDS Alerts Aggregation Algorithm Based on Rough Set Theory

    NASA Astrophysics Data System (ADS)

    Zhang, Ru; Guo, Tao; Liu, Jianyi

    2018-03-01

    Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.

  16. Alertness and cognitive control: Toward a spatial grouping hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    A puzzling interaction involving alertness and cognitive control is indicated by the finding of faster performance but larger congruency effects on alert trials (on which alerting cues are presented before the task stimuli) than on no-alert trials in selective attention tasks. In the present study, the author conducted four experiments to test hypotheses about the interaction. Manipulation of stimulus spacing revealed a difference in congruency effects between alert and no-alert trials for narrowly spaced stimuli but not for widely spaced stimuli, inconsistent with the hypothesis that increased alertness is associated with more diffuse attention. Manipulation of color grouping revealed similar differences in congruency effects between alert and no-alert trials for same-color and different-color groupings of targets and distractors, inconsistent with the general hypothesis that increased alertness is associated with more perceptual grouping. To explain the results, the author proposes that increased alertness is associated specifically with more spatial grouping of stimuli, possibly by modulating the threshold for parsing stimulus displays into distinct objects.

  17. Aerosol collection of the (Bladewerx Corporation) breathing zone monitor and portable workplace monitor.

    PubMed

    Moore, Murray E; Kennedy, Trevor J; Dimmerling, Paul J

    2007-11-01

    The Radiation Protection Group at the Los Alamos National Laboratory has a wind tunnel capable of measuring the aerosol collection efficiencies of air sampling devices. In the fall of 2005, the group received an internal Los Alamos request to perform aerosol collection efficiency tests on two air samplers manufactured by the Bladewerx Corporation (Rio Rancho, NM). This paper presents the results from tests performed in the wind tunnel facility at a test velocity of 0.5 m s. The SabreAlert (Portable Workplace Monitor) and the SabreBZM (Breathing Zone Monitor) are both designed to detect and measure the presence of alpha emitting isotopes in atmospheres. The SabreAlert was operated at two test air flow rates of 6 and 45 liters per minute (LPM), and the SabreBZM was operated at two test air flow rates of 3 and 19 LPM. The aerosol collection efficiencies of both samplers were evaluated with oleic acid (monodisperse) liquid droplet aerosols tagged with sodium fluorescein tracer. These test aerosols varied in size from about 2.3 to 17.2 microns (aerodynamic equivalent diameter). The SabreAlert was roughly 100% efficient in aerosol collection at a flow rate of 6 LPM, and had an aerodynamic cutpoint diameter of 11.3 microns at the 45 LPM flow rate. The SabreBZM had an aerodynamic cutpoint diameter of 6.7 microns at the 3 LPM flow rate, but the SabreBZM aerosol collection efficiency never exceeded 13.6% at the 19 LPM test flow rate condition.

  18. NASA Aviation Safety Reporting System

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A comprehensive study of near midair collisions in terminal airspace, derived from the ASRS database is presented. A selection of controller and pilot reports on airport perimeter security, unauthorized takeoffs and landings, and on winter operations is presented. A sampling of typical Alert Bulletins and their responses is presented.

  19. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite...; or (iii) Through the INMARSAT geostationary satellite service if within INMARSAT coverage; this....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  20. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite...; or (iii) Through the INMARSAT geostationary satellite service if within INMARSAT coverage; this....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  1. 75 FR 6343 - Information Collection Activity; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-09

    ... Independence Ave., SW., Washington, DC 20250-1522. FAX: (202) 720-4120. Title: Weather Radio Transmitter Grant... collection. Abstract: The National Weather Service operates an All Hazards Early Warning System that alerts people in areas covered by its transmissions of approaching dangerous weather and other emergencies. The...

  2. Proactive authenticated notifications for health practitioners: two way human computer interaction through phone.

    PubMed

    Majeed, Raphael W; Stöhr, Mark R; Röhrig, Rainer

    2012-01-01

    Notifications and alerts play an important role in clinical daily routine. Rising prevalence of clinical decision support systems and electronic health records also result in increasing demands on notification systems. Failure adequately to communicate a critical value is a potential cause of adverse events. Critical laboratory values and changing vital data depend on timely notifications of medical staff. Vital monitors and medical devices rely on acoustic signals for alerting which are prone to "alert fatigue" and require medical staff to be present within audible range. Personal computers are unsuitable to display time critical notification messages, since the targeted medical staff are not always operating or watching the computer. On the other hand, mobile phones and smart devices enjoy increasing popularity. Previous notification systems sending text messages to mobile phones depend on asynchronous confirmations. By utilizing an automated telephony server, we provide a method to deliver notifications quickly and independently of the recipients' whereabouts while allowing immediate feedback and confirmations. Evaluation results suggest the feasibility of the proposed notification system for real-time notifications.

  3. User's guide to SSARRMENU

    USGS Publications Warehouse

    Mastin, M.C.; Le, Thanh

    2001-01-01

    The U.S. Geological Survey, in cooperation with Pierce County Department of Public Works, Washington, has developed an operational tool called the Puyallup Flood-Alert System to alert users of impending floods in the Puyallup River Basin. The system acquires and incorporates meteorological and hydrological data into the Streamflow Synthesis and Reservoir Regulation (SSARR) hydrologic flow-routing model to simulate floods in the Puyallup River Basin. SSARRMENU is the user-interactive graphical interface between the user, the input and output data, and the SSARR model. In a companion cooperative project with Pierce County, the SSARR model for the Puyallup River Basin was calibrated and validated. The calibrated model is accessed through SSARRMENU, which has been specifically programed for the Puyallup River and the needs of Pierce County. SSARRMENU automates the retrieval of data from ADAPS (Automated DAta Processing System, the U.S. Geological Survey?s real-time hydrologic database), formats the data for use with SSARR, initiates SSARR model runs, displays alerts for impending floods, and provides utilities to display the simulated and observed data. An on-screen map of the basin and a series of menu items provide the user wi

  4. Managing the Alert Process at NewYork-Presbyterian Hospital

    PubMed Central

    Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary

    2005-01-01

    Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073

  5. Olefin unit primary fractionator on-line Petro-Blast Lancing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, W.D.; Rutan, C.R.

    1994-12-31

    Today`s commodity chemicals market forces companies to find innovative ways to extend unit on line operation between turnarounds such that they will remain economically competitive. At the OxyChem Chocolate Bayou facility the Primary Fractionator, quench oil column, fouling defined the length of the run between Olefin Unit turnarounds. Polymer growth on the valve trays restricted vapor flow through the column. This increased the column pressure drop which resulted in severe flooding. The inability to cool the furnace effluent while separating the fuel oil and gasoline components would cause premature shutdowns. Fouling locations were defined using gamma scan techniques and pressuremore » surveys. Nozzles were welded and hot tapped at strategic locations around the column. A high pressure Petro-Blast Lancing technique, inserted through the nozzles, was then used to clean the trays. The operation has extended the unit run length although the column may require additional Petro-Blast Lancing before the next scheduled plant turnaround. If this schedule holds, a two year extension in the unit run length will be realized.« less

  6. Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique.

    PubMed

    Ghiyas Ud Din; Imran Rafiq Chughtai; Hameed Inayat, Mansoor; Hussain Khan, Iqbal

    2009-01-01

    Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and (99m)Tc in the form of sodium pertechnetate eluted from a (99)Mo/(99m)Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer (99m)Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.

  7. Optimizing drug-dose alerts using commercial software throughout an integrated health care system.

    PubMed

    Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C

    2017-11-01

    All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Quasi-adiabatic vacuum-based column housing for very high-pressure liquid chromatography.

    PubMed

    Gritti, Fabrice; Gilar, Martin; Jarrell, Joseph A

    2016-07-22

    A prototype vacuum-based (10(-6)Torr) column housing was built to thermally isolate the chromatographic column from the external air environment. The heat transfer mechanism is solely controlled by surface radiation, which was minimized by wrapping the column with low-emissivity aluminum tape. The adiabaticity of the column housing was quantitatively assessed from the measurement of the operational pressure and fluid temperature at the outlet of a 2.1mm×100mm column (sub-2 μm particles). The pressure drop along the column was raised up to 1kbar. The enthalpy balance of the eluent (water, acetonitrile, and one water/acetonitrile mixture, 70/30, v/v) showed that less than 1% of the viscous heat generated by friction of the fluid against the packed bed was lost to the external air environment. Such a vacuum-based column oven minimizes the amplitude of the radial temperature gradients across the column diameter and maximizes its resolving power. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. A systematic review of the effectiveness of interruptive medication prescribing alerts in hospital CPOE systems to change prescriber behavior and improve patient safety.

    PubMed

    Page, N; Baysari, M T; Westbrook, J I

    2017-09-01

    To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions about the amount and type of decision support that should be integrated into CPOE systems to increase safety while reducing the risk of alert fatigue. Virtually no studies have sought to investigate the impact on changes to prescriber behavior and outcomes overall when alerts from multiple categories are incorporated within the same system. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Tsunami vulnerability of buildings and people in South Java - field observations after the July 2006 Java tsunami

    NASA Astrophysics Data System (ADS)

    Reese, S.; Cousins, W. J.; Power, W. L.; Palmer, N. G.; Tejakusuma, I. G.; Nugrahadi, S.

    2007-10-01

    A team of scientists from New Zealand and Indonesia undertook a reconnaissance mission to the South Java area affected by the tsunami of 17 July 2006. The team used GPS-based surveying equipment to measure ground profiles and inundation depths along 17 transects across affected areas near the port city of Cilacap and the resort town of Pangandaran. The purpose of the work was to acquire data for calibration of models used to estimate tsunami inundations, casualty rates and damage levels. Additional information was gathered from interviews with eyewitnesses. The degree of damage observed was diverse, being primarily dependant on water depth and the building construction type. Water depths were typically 2 to 4 m where housing was seriously damaged. Damage levels ranged from total for older brick houses, to about 50% for newer buildings with rudimentary reinforced-concrete beams and columns, to 5-20% for engineered residential houses and multi-storey hotels with heavier RC columns. "Punchout" of weak brick walls was widespread. Despite various natural warning signs very few people were alerted to the impending tsunami. Hence, the death toll was significant, with average death and injury rates both being about 10% of the people exposed, for water depths of about 3 m.

  11. Proceedings of the Annual ONR/CADRC Decision-Support Workshop (6th), Held in Quantico, Virginia, on 8-9 Sep 2004. Interoperability

    DTIC Science & Technology

    2004-11-01

    fixed schedule checkups and overhauls), Underway Replenishment (the goal being operation in sea states 3 and higher via technical improvements to...determine whether sufficient local resources are available to deal with current conditions. Scheduling Agent: Assists the Emergency Operations Bureau to...will commence per predefined schedule within 15 minutes) and subsequently alerts its subscribers that the rolling power blackout has commenced. The

  12. Prescription order risk factors for pediatric dosing alerts.

    PubMed

    Stultz, J S; Porter, K; Nahata, M C

    2015-02-01

    To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.

    PubMed

    Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A

    2017-11-01

    Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.

  14. Factors influencing alert acceptance: a novel approach for predicting the success of clinical decision support

    PubMed Central

    Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E

    2011-01-01

    Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746

  15. Evaluation of 1.0 mm i.d. column performances on ultra high pressure liquid chromatography instrumentation.

    PubMed

    Lestremau, François; Wu, Di; Szücs, Roman

    2010-07-23

    The present study focuses on the evaluation of 1.0 mm i.d. (internal diameter) columns on a commercial Ultra-High Pressure system. These systems have been developed specifically to operate columns with small volumes, typically 2.1 mm i.d., by reducing extra-column volume dispersion. The use of columns with smaller i.d. results in a reduced solvent consumption and required sample volume. The evaluation of the columns was carried out with samples containing neutral and pharmaceutical compounds. In isocratic mode, the extra-column volume produced additional band broadening leading to poor performances compared to equivalent 2.1 mm i.d. columns. By increasing the length of the column, the influence of the extra-column bandspreading could be reduced and 75,000 plates were obtained when four columns were coupled. In gradient mode, the effect of the extra-column contribution on efficiency was limited and about 80% of the performance of the 2.1 mm i.d. columns was obtained. Optimum conditions in gradient mode were further investigated by changing flow rate, gradient time and column length. A different approach of the calculation of peak capacity was also considered for the comparison of the influence of these different parameters. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  16. Optimization of drug-drug interaction alert rules in a pediatric hospital's electronic health record system using a visual analytics dashboard.

    PubMed

    Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D

    2015-03-01

    To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (p<0.001). For providers, baseline median alert rate prior to the first round of DDI deactivation was 19.73 alerts/100 orders (IQR 18.66-20.24) and 15.11 alerts/100 orders (IQR 14.44-15.49) following the three interventions (p<0.001). In a subgroup analysis, we observed a decrease in pharmacists' override rates for DDI alerts that were not modified in the system from a median of 93.06 overrides/100 alerts (IQR 91.96-94.33) to 85.68 overrides/100 alerts (IQR 84.29-87.15, p<0.001). The medication serious safety event rate decreased during the study period, and there were no serious safety events reported in association with the deactivated alert rules. An alert dashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Provider management strategies of abnormal test result alerts: a cognitive task analysis.

    PubMed

    Hysong, Sylvia J; Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Electronic medical records (EMRs) facilitate abnormal test result communication through "alert" notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results.

  18. Using crowd sourcing to combat potentially illegal or dangerous UAV operations

    NASA Astrophysics Data System (ADS)

    Tapsall, Brooke T.

    2016-10-01

    The UAV (Unmanned Aerial Vehicles) industry is growing exponentially at a pace that policy makers, individual countries and law enforcement agencies are finding difficult to keep up. The UAV market is large, as such the amount of UAVs being operated in potentially dangerous situations is prevalent and rapidly increasing. Media is continually reporting `near-miss' incidents between UAVs and commercial aircraft, UAV breaching security in sensitive areas or invading public privacy. One major challenge for law enforcement agencies is gaining tangible evidence against potentially dangerous or illegal UAV operators due to the rapidity with which UAV operators are able to enter, fly and exit a scene before authorities can arrive or before they can be located. DroneALERT, an application available via the Airport-UAV.com website, allows users to capture potentially dangerous or illegal UAV activity using their mobile device as it the incident is occurring. A short online DroneALERT Incident Report (DIR) is produced, emailed to the user and the Airport-UAV.com custodians. The DIR can be used to aid authorities in their investigations. The DIR contains details such as images and videos, location, time, date of the incident, drone model, its distance and height. By analysing information from the DIR, photos or video, there is a high potential for law enforcement authorities to use this evidence to identify the type of UAV used, triangulate the location of the potential dangerous UAV and operator, create a timeline of events, potential areas of operator exit and to determine the legalities breached. All provides crucial evidence for identifying and prosecuting a UAV operator.

  19. Randomized prospective study comparing tri-cortical iliac crest autograft to allograft in the lateral column lengthening component for operative correction of adult acquired flatfoot deformity.

    PubMed

    Dolan, Christopher M; Henning, Jeffrey A; Anderson, John G; Bohay, Donald R; Kornmesser, Marc J; Endres, Terrence J

    2007-01-01

    Operative treatment of stage II posterior tibial tendon insufficiency (PTTI) is controversial. Many soft-tissue and bony procedures and various combinations of the two have been reported for treatment of stage II PTTI. Orthopaedists recognize the lateral column lengthening component of the procedure as a successful reconstructive technique. The use of cortical allograft for lateral column lengthening in the correction of pes planus in the pediatric patient population has been routine. In the adult population, however, tricortical iliac crest autograft has been the bone graft of choice. Harvest of this autograft can precipitate significant morbidity and cost. Therefore, we undertook this randomized controlled trial to compare graft incorporation and healing of allograft and autograft in the lateral column lengthening component of adult flatfoot reconstruction. Lateral column lengthening was done as a component of operative correction for stage II PTTI in adult patients (older than 18 years) by two surgeons using similar procedures. The patients were randomized to either the allograft or autograft procedures. The primary endpoint was graft incorporation and healing as assessed by radiographs. The study included 33 randomized feet in 31 patients. We followed 18 feet in the allograft group and 15 in the autograft group to the point of union. There were 21 women and 10 men. There were no delayed unions, nonunions, or hardware failures. All patients in both groups achieved bony union by the 12-week followup evaluation. Two superficial foot infections were successfully treated with oral antibiotics. Two patients in the autograft group continued to have hip donor site pain at 3 months. This study suggests that union rates of allograft and autograft (iliac crest bone graft) are equal. The use of allograft in the lateral column lengthening component of operative correction of adult stage II PTTI appears to be a viable alternative to the use of iliac crest autograft and eliminates the morbidity and increased cost associated with autograft harvest.

  20. Use of RSM for the multivariate, simultaneous multiobjective optimization of the operating conditions of aliphatic carboxylic acids ion-exclusion chromatography column: Quantitative study of hydrodynamic, isotherm, and thermodynamic behavior.

    PubMed

    Shojaeimehr, Tahereh; Rahimpour, Farshad; Schwarze, Michael; Repke, Jens-Uwe; Godini, Hamid Reza; Wozny, Günter

    2018-04-15

    The present study evaluates the capability of ion exclusion chromatography (IEC) of short chain aliphatic carboxylic acids using a cation exchange column (8% sulfonated cross-linked styrene-divinylbenzene copolymer) in different experimental conditions. Since one of the prerequisites to the development of an efficient carboxylic acid separation process is to obtain the optimum operational conditions, response surface methodology (RSM) was used to develop an approach to evaluate carboxylic acids separation process in IEC columns. The effect of the operating conditions such as column temperature, sulfuric acid concentration as the mobile phase, and the flow rate was studied using Central Composite Face (CCF) design. The optimum operating conditions for the separate injection of lactic acid and acetic acid is temperature of 75 °C, sulfuric acid concentration of 0.003 N for both acids and flow rate of 0.916 (0.886) mL/min for acetic acid (lactic acid). Likewise, the optimum conditions for the simultaneous injection of acetic and lactic acid mixture are the column temperature of 68 °C, sulfuric acid concentration of 0.0003 N, and flow rate of 0.777 mL/min. In the next step, the adsorption equilibria of acetic acid and lactic acid on the stationary phase were investigated through a series of Frontal Analysis (FA), Frontal Analysis by Characteristic Points (FACP), and using Langmuir isotherm model. The results showed an excellent agreement between the model and experimental data. Finally, the results of thermodynamic studies proved that the IEC process for separation of acetic and lactic acid is a spontaneous, feasible, exothermic, and random process with a physical adsorption mechanism. The results of the current paper can be a valuable information in the stages of designing IEC columns for separation of aliphatic carboxylic acids. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. 77 FR 46943 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-07

    ... compliance time; therefore, an operator may choose to add the reinforcing fiberglass overcoat before the... discrepant quantities of nut plates and types of fasteners called out in Boeing Alert Service Bulletin 747... different airplane configuration that might use a different quantity of nut plates than what is specified in...

  2. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite... the ship is normally navigated); or (ii) On HF using DSC; or (iii) Through the INMARSAT geostationary....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  3. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite... the ship is normally navigated); or (ii) On HF using DSC; or (iii) Through the INMARSAT geostationary....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  4. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite... the ship is normally navigated); or (ii) On HF using DSC; or (iii) Through the INMARSAT geostationary....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  5. Seismic Awareness : Transportation Facilities : A Primer for Transportation Managers on Earthquake Hazards and Measures for Reducing Vulnerability

    DOT National Transportation Integrated Search

    1993-12-01

    The purpose of this report is to alert managers and operators of transportation enterprises, in both the public and private sector, to the dangers of earthquakes to buildings and possible precautions to be taken. The nature of seismic hazards in the ...

  6. Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities at surface monitoring sites

    NASA Astrophysics Data System (ADS)

    Kobayashi, N.; Inoue, G.; Kawasaki, M.; Yoshioka, H.; Minomura, M.; Murata, I.; Nagahama, T.; Matsumi, Y.; Tanaka, T.; Morino, I.; Ibuki, T.

    2010-08-01

    Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities were developed in two independent systems: one utilizing a grating-based desktop optical spectrum analyzer (OSA) with a resolution enough to resolve rotational lines of CO2 and CH4 in the regions of 1565-1585 and 1674-1682 nm, respectively; the other is an application of an optical fiber Fabry-Perot interferometer (FFPI) to obtain the CO2 column density. Direct sunlight was collimated via a small telescope installed on a portable sun tracker and then transmitted through an optical fiber into the OSA or the FFPI for optical analysis. The near infrared spectra of the OSA were retrieved by a least squares spectral fitting algorithm. The CO2 and CH4 column densities deduced were in excellent agreement with those measured by a Fourier transform spectrometer with high resolution. The rovibronic lines in the wavelength region of 1570-1575 nm were analyzed by the FFPI. The I0 and I values in the Beer-Lambert law equation to obtain CO2 column density were deduced by modulating temperature of the FFPI, which offered column CO2 with the statistical error less than 0.2% for six hours measurement.

  7. Neurophysiological detection of impending spinal cord injury during scoliosis surgery.

    PubMed

    Schwartz, Daniel M; Auerbach, Joshua D; Dormans, John P; Flynn, John; Drummond, Denis S; Bowe, J Andrew; Laufer, Samuel; Shah, Suken A; Bowen, J Richard; Pizzutillo, Peter D; Jones, Kristofer J; Drummond, Denis S

    2007-11-01

    Despite the many reports attesting to the efficacy of intraoperative somatosensory evoked potential monitoring in reducing the prevalence of iatrogenic spinal cord injury during corrective scoliosis surgery, these afferent neurophysiological signals can provide only indirect evidence of injury to the motor tracts since they monitor posterior column function. Early reports on the use of transcranial electric motor evoked potentials to monitor the corticospinal motor tracts directly suggested that the method holds great promise for improving detection of emerging spinal cord injury. We sought to compare the efficacy of these two methods of monitoring to detect impending iatrogenic neural injury during scoliosis surgery. We reviewed the intraoperative neurophysiological monitoring records of 1121 consecutive patients (834 female and 287 male) with adolescent idiopathic scoliosis (mean age, 13.9 years) treated between 2000 and 2004 at four pediatric spine centers. The same group of experienced surgical neurophysiologists monitored spinal cord function in all patients with use of a standardized multimodality technique with the patient under total intravenous anesthesia. A relevant neurophysiological change (an alert) was defined as a reduction in amplitude (unilateral or bilateral) of at least 50% for somatosensory evoked potentials and at least 65% for transcranial electric motor evoked potentials compared with baseline. Thirty-eight (3.4%) of the 1121 patients had recordings that met the criteria for a relevant signal change (i.e., an alert). Of those thirty-eight patients, seventeen showed suppression of the amplitude of transcranial electric motor evoked potentials in excess of 65% without any evidence of changes in somatosensory evoked potentials. In nine of the thirty-eight patients, the signal change was related to hypotension and was corrected with augmentation of the blood pressure. The remaining twenty-nine patients had an alert that was related directly to a surgical maneuver. Three alerts occurred following segmental vessel clamping, and the remaining twenty-six were related to posterior instrumentation and correction. Nine (35%) of these twenty-six patients with an instrumentation-related alert, or 0.8% of the cohort, awoke with a transient motor and/or sensory deficit. Seven of these nine patients presented solely with a motor deficit, which was detected by intraoperative monitoring of transcranial electric motor evoked potentials in all cases, and two patients had only sensory symptoms. Somatosensory evoked potential monitoring failed to identify a motor deficit in four of the seven patients with a confirmed motor deficit. Furthermore, when changes in somatosensory evoked potentials occurred, they lagged behind the changes in transcranial electric motor evoked potentials by an average of approximately five minutes. With an appropriate response to the alert, the motor or sensory deficit resolved in all nine patients within one to ninety days. This study underscores the advantage of monitoring the spinal cord motor tracts directly by recording transcranial electric motor evoked potentials in addition to somatosensory evoked potentials. Transcranial electric motor evoked potentials are exquisitely sensitive to altered spinal cord blood flow due to either hypotension or a vascular insult. Moreover, changes in transcranial electric motor evoked potentials are detected earlier than are changes in somatosensory evoked potentials, thereby facilitating more rapid identification of impending spinal cord injury.

  8. The NAS Alert System: A look at the first eight years

    USGS Publications Warehouse

    Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.

    2013-01-01

    The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.

  9. [Monitoring method for macroporous resin column chromatography process of salvianolic acids based on near infrared spectroscopy].

    PubMed

    Hou, Xiang-Mei; Zhang, Lei; Yue, Hong-Shui; Ju, Ai-Chun; Ye, Zheng-Liang

    2016-07-01

    To study and establish a monitoring method for macroporous resin column chromatography process of salvianolic acids by using near infrared spectroscopy (NIR) as a process analytical technology (PAT).The multivariate statistical process control (MSPC) model was developed based on 7 normal operation batches, and 2 test batches (including one normal operation batch and one abnormal operation batch) were used to verify the monitoring performance of this model. The results showed that MSPC model had a good monitoring ability for the column chromatography process. Meanwhile, NIR quantitative calibration model was established for three key quality indexes (rosmarinic acid, lithospermic acid and salvianolic acid B) by using partial least squares (PLS) algorithm. The verification results demonstrated that this model had satisfactory prediction performance. The combined application of the above two models could effectively achieve real-time monitoring for macroporous resin column chromatography process of salvianolic acids, and can be used to conduct on-line analysis of key quality indexes. This established process monitoring method could provide reference for the development of process analytical technology for traditional Chinese medicines manufacturing. Copyright© by the Chinese Pharmaceutical Association.

  10. Microengineered open tubular columns for GC analysis

    NASA Astrophysics Data System (ADS)

    Wiranto, Goib; Haskard, Malcolm R.; Mulcahy, Dennis E.; Davey, David E.; Dawes, Ernest F.

    1999-09-01

    Microengineered open tubular (MOT) columns with semi rectangular cross-sections have been designed and fabricated using microengineering techniques. The creation of 100-micrometers wide, 20-micrometers deep, and 125-cm long columns employed isotropic etching on (100) silicon and anodic bonding with a Pyrex 7740 glass cover plate. Column geometry has been optimized to achieve maximum efficiency and allow extreme operating conditions. The walls of the microcolumns were coated with a non-polar liquid stationary phase. Performances of the MOT columns have been demonstrated by their ability to completely separate a series of hydrocarbon mixture in less than 1.25 min under isothermal condition of 150 degrees C. The achievable column efficiencies as measured in terms of theoretical plate height ranged from 0.57 to 1.45 mm, which agreed well with theoretical predictions.

  11. Glass-silicon column

    DOEpatents

    Yu, Conrad M.

    2003-12-30

    A glass-silicon column that can operate in temperature variations between room temperature and about 450.degree. C. The glass-silicon column includes large area glass, such as a thin Corning 7740 boron-silicate glass bonded to a silicon wafer, with an electrode embedded in or mounted on glass of the column, and with a self alignment silicon post/glass hole structure. The glass/silicon components are bonded, for example be anodic bonding. In one embodiment, the column includes two outer layers of silicon each bonded to an inner layer of glass, with an electrode imbedded between the layers of glass, and with at least one self alignment hole and post arrangement. The electrode functions as a column heater, and one glass/silicon component is provided with a number of flow channels adjacent the bonded surfaces.

  12. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation

    PubMed Central

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-01-01

    Objective To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. Materials and methods We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug–allergy, drug–drug interaction, and drug–disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Results Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1–5) compared to original alerts: 4 (1–7); p=0.024). Discussion Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. Conclusions This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. PMID:24668841

  13. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation.

    PubMed

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-10-01

    To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug-allergy, drug-drug interaction, and drug-disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1-5) compared to original alerts: 4 (1-7); p=0.024). Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Provider acceptance of an automated electronic alert for acute kidney injury

    PubMed Central

    Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry

    2016-01-01

    Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598

  15. Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors

    PubMed Central

    Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W

    2011-01-01

    Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158

  16. High-efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable I. Experiments with 25 cm x 4.6 mm I.D., 5 microm ODS columns.

    PubMed

    Lestremau, François; Cooper, Andrew; Szucs, Roman; David, Frank; Sandra, Pat

    2006-03-24

    High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.

  17. A new method for the preparation of polymeric porous layer open tubular columns for GC application

    NASA Technical Reports Server (NTRS)

    Shen, T. C.; Wang, M. L.

    1995-01-01

    A new method to prepare polymeric PLOT columns by using in situ polymerization technology is described. The method involves a straightforward in situ polymerization of the monomer. The polymer produced is directly coated on the metal tubing. This eliminates many of the steps needed in conventional polymeric PLOT column preparation. Our method is easy to operate and produces very reproducible columns, as shown previously (T. C. Shen. J. Chromatogr. Sci. 30, 239, 1992). The effects of solvents, tubing pretreatments, initiators and reaction temperatures in the preparation of PLOT columns are studied. Several columns have been developed to separate (1) highly polar compounds, such as water and ammonia or water and HCN, and (2) hydrocarbons and inert gases. A recent improvement has allowed us to produce bonded polymeric PLOT columns. These were studied, and the results are included also.

  18. Interspecies Extrapolations of Halocarbon Respiratory and Tissue Kinetics: Applications to Predicting Toxicity in Different Species

    DTIC Science & Technology

    1994-08-15

    repository for TCE, and thus a critical determinant of TCE’s pharmacokinetics. As previously mentioned, it is advantageous to have quantitative tcxicity...steel columns (182 cm x 0.317 cm) packed with 10% FFAP ( Alltech Associates, Deerfield, IL). The GC operating conditions were: headspace sampler...steel columns (182 cm x 0.317 cm) packed with 10% FFAP ( Alltech Associates, Deerfield, IL). The GC operating conditions were: headspace sampler

  19. Continuous desalting of refolded protein solution improves capturing in ion exchange chromatography: A seamless process.

    PubMed

    Walch, Nicole; Jungbauer, Alois

    2017-06-01

    Truly continuous biomanufacturing processes enable an uninterrupted feed stream throughout the whole production without the need for holding tanks. We have utilized microporous anion and cation exchangers into which only salts, but not proteins, can penetrate into the pores for desalting of protein solutions, while diafiltration or dilution is usually employed for feed adjustments. Anion exchange and cation exchange chromatography columns were connected in series to remove both anions and cations. To increase operation performance, a continuous process was developed comprised of four columns. Continuous mode was achieved by staggered cycle operation, where one set of columns, consisting of one anion exchange and one cation exchange column, was loaded during the regeneration of the second set. Refolding, desalting and subsequent ion exchange capturing with a scFv as the model protein was demonstrated. The refolding solution was successfully desalted resulting in a consistent conductivity below 0.5 mS/cm from initial values of 10 to 11 mS/cm. With continuous operation process time could be reduced by 39% while productivity was increased to 163% compared to batch operation. Desalting of the protein solution resulted in up to 7-fold higher binding capacities in the subsequent ion exchange capture step with conventional protein binding resins. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Improved Signal Chains for Readout of CMOS Imagers

    NASA Technical Reports Server (NTRS)

    Pain, Bedabrata; Hancock, Bruce; Cunningham, Thomas

    2009-01-01

    An improved generic design has been devised for implementing signal chains involved in readout from complementary metal oxide/semiconductor (CMOS) image sensors and for other readout integrated circuits (ICs) that perform equivalent functions. The design applies to any such IC in which output signal charges from the pixels in a given row are transferred simultaneously into sampling capacitors at the bottoms of the columns, then voltages representing individual pixel charges are read out in sequence by sequentially turning on column-selecting field-effect transistors (FETs) in synchronism with source-follower- or operational-amplifier-based amplifier circuits. The improved design affords the best features of prior source-follower-and operational- amplifier-based designs while overcoming the major limitations of those designs. The limitations can be summarized as follows: a) For a source-follower-based signal chain, the ohmic voltage drop associated with DC bias current flowing through the column-selection FET causes unacceptable voltage offset, nonlinearity, and reduced small-signal gain. b) For an operational-amplifier-based signal chain, the required bias current and the output noise increase superlinearly with size of the pixel array because of a corresponding increase in the effective capacitance of the row bus used to couple the sampled column charges to the operational amplifier. The effect of the bus capacitance is to simultaneously slow down the readout circuit and increase noise through the Miller effect.

  1. Provider management strategies of abnormal test result alerts: a cognitive task analysis

    PubMed Central

    Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Objective Electronic medical records (EMRs) facilitate abnormal test result communication through “alert” notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. Design 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Results Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Conclusion Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results. PMID:20064805

  2. The potential role of real-time geodetic observations in tsunami early warning

    NASA Astrophysics Data System (ADS)

    Tinti, Stefano; Armigliato, Alberto

    2016-04-01

    Tsunami warning systems (TWS) have the final goal to launch a reliable alert of an incoming dangerous tsunami to coastal population early enough to allow people to flee from the shore and coastal areas according to some evacuation plans. In the last decade, especially after the catastrophic 2004 Boxing Day tsunami in the Indian Ocean, much attention has been given to filling gaps in the existing TWSs (only covering the Pacific Ocean at that time) and to establishing new TWSs in ocean regions that were uncovered. Typically, TWSs operating today work only on earthquake-induced tsunamis. TWSs estimate quickly earthquake location and size by real-time processing seismic signals; on the basis of some pre-defined "static" procedures (either based on decision matrices or on pre-archived tsunami simulations), assess the tsunami alert level on a large regional scale and issue specific bulletins to a pre-selected recipients audience. Not unfrequently these procedures result in generic alert messages with little value. What usually operative TWSs do not do, is to compute earthquake focal mechanism, to calculate the co-seismic sea-floor displacement, to assess the initial tsunami conditions, to input these data into tsunami simulation models and to compute tsunami propagation up to the threatened coastal districts. This series of steps is considered nowadays too time consuming to provide the required timely alert. An equivalent series of steps could start from the same premises (earthquake focal parameters) and reach the same result (tsunami height at target coastal areas) by replacing the intermediate steps of real-time tsunami simulations with proper selection from a large archive of pre-computed tsunami scenarios. The advantage of real-time simulations and of archived scenarios selection is that estimates are tailored to the specific occurring tsunami and alert can be more detailed (less generic) and appropriate for local needs. Both these procedures are still at an experimental or testing stage and haven't been implemented yet in any standard TWS operations. Nonetheless, this is seen to be the future and the natural TWS evolving enhancement. In this context, improvement of the real-time estimates of tsunamigenic earthquake focal mechanism is of fundamental importance to trigger the appropriate computational chain. Quick discrimination between strike-slip and thrust-fault earthquakes, and equally relevant, quick assessment of co-seismic on-fault slip distribution, are exemplary cases to which a real-time geodetic monitoring system can contribute significantly. Robust inversion of geodetic data can help to reconstruct the sea floor deformation pattern especially if two conditions are met: the source is not too far from network stations and is well covered azimuthally. These two conditions are sometimes hard to satisfy fully, but in certain regions, like the Mediterranean and the Caribbean sea, this is quite possible due to the limited size of the ocean basins. Close cooperation between the Global Geodetic Observing System (GGOS) community, seismologists, tsunami scientists and TWS operators is highly recommended to obtain significant progresses in the quick determination of the earthquake source, which can trigger a timely estimation of the ensuing tsunami and a more reliable and detailed assessment of the tsunami size at the coast.

  3. Operational trace gas column observations from GOME-2 on MetOp

    NASA Astrophysics Data System (ADS)

    Valks, Pieter; Hao, Nan; Pinardi, Gaia; Hedelt, Pascal; Liu, Song; Van Roozendael, Michel; De Smedt, Isabelle; Theys, Nicolas; Koukouli, MariLiza; Balis, Dimitris

    2017-04-01

    This contribution focuses on the operational GOME-2 trace gas column products developed in the framework of EUMETSAT's Satellite Application Facility on Atmospheric Composition Monitoring (AC-SAF). We present an overview of the retrieval algorithms for ozone, OClO, NO2, SO2 and formaldehyde, and we show examples of various applications such as air quality and climate monitoring, using observations from the GOME-2 instruments on MetOp-A and MetOp-B. Total ozone and the minor trace gas columns from GOME-2 are retrieved with the latest version 4.8 of the GOME Data Processor (GDP), which uses an optimized Differential Optical Absorption Spectroscopy (DOAS) algorithm, with air mass factor conversions based on the LIDORT model. Improved total and tropospheric NO2 columns are retrieved in the visible wavelength region between 425 and 497 nm. SO2 emissions from volcanic and anthropogenic sources can be measured by GOME-2 using the UV wavelength region around 320 nm. For formaldehyde, an optimal DOAS fitting window around 335 nm has been determined for GOME-2. The GOME-2 trace gas columns have reached the operational EUMETSAT product status, and are available to the users in near real time (within two hours after sensing by GOME-2). The use of trace gas observations from the GOME-2 instruments on MetOp-A and MetOp-B for air quality purposed will be illustrated, e.g. for South-East Asia and Europe. Furthermore, comparisons of the GOME-2 satellite observations with ground-based measurements will be shown. Finally, the use of GOME-2 trace-gas column data in the Copernicus Atmosphere Monitoring Service (CAMS) will be presented.

  4. Task Force Resettlement Operation, After Action Report, Fort Chaffee, Arkansas, 7 May 1980-19 February 1982

    DTIC Science & Technology

    1982-06-09

    authority to use non-lethal force must be established at the very beginning of such an operation, especially in light of the limited manpower available to the...references, and accurate interpretations of the law, especially as to jurisdictiopal matters, are critical. RECOMMENDATION: It is reccmmended that in...appropriate. Intensive planning,training/rehearsal, and practice alerts was essential, especially so as units rotated every 60 days. In effect, the

  5. FIM Avionics Operations Manual

    NASA Technical Reports Server (NTRS)

    Alves, Erin E.

    2017-01-01

    This document describes the operation and use of the Flight Interval Management (FIM) Application installed on an electronic flight bag (EFB). Specifically, this document includes: 1) screen layouts for each page of the interface; 2) step-by-step instructions for data entry, data verification, and input error correction; 3) algorithm state messages and error condition alerting messages; 4) aircraft speed guidance and deviation indications; and 5) graphical display of the spatial relationships between the Ownship aircraft and the Target aircraft.

  6. Operational Arctic: The Potential for Crisis or Conflict in the Arctic Region and Application of Operational Art

    DTIC Science & Technology

    2014-05-22

    PRC Peoples Republic of China SAMS School of Advanced Military Studies SLOC Sea Lines of Communication SSI Strategic Studies Institute UN...the North” (Monograph, School of Advanced Military Studies, 2013), 1. 5Robert Sibley, “Arrival of China in Arctic puts Canada on Alert,” Ottawa...the possibility of resource wealth or shipping opportunities.10 Some of the world’s more powerful and wealthy nations, Russia, Canada, China , and

  7. Impact of Pilot Delay and Non-Responsiveness on the Safety Performance of Airborne Separation

    NASA Technical Reports Server (NTRS)

    Consiglio, Maria; Hoadley, Sherwood; Wing, David; Baxley, Brian; Allen, Bonnie Danette

    2008-01-01

    Assessing the safety effects of prediction errors and uncertainty on automationsupported functions in the Next Generation Air Transportation System concept of operations is of foremost importance, particularly safety critical functions such as separation that involve human decision-making. Both ground-based and airborne, the automation of separation functions must be designed to account for, and mitigate the impact of, information uncertainty and varying human response. This paper describes an experiment that addresses the potential impact of operator delay when interacting with separation support systems. In this study, we evaluated an airborne separation capability operated by a simulated pilot. The experimental runs are part of the Safety Performance of Airborne Separation (SPAS) experiment suite that examines the safety implications of prediction errors and system uncertainties on airborne separation assistance systems. Pilot actions required by the airborne separation automation to resolve traffic conflicts were delayed within a wide range, varying from five to 240 seconds while a percentage of randomly selected pilots were programmed to completely miss the conflict alerts and therefore take no action. Results indicate that the strategicAirborne Separation Assistance System (ASAS) functions exercised in the experiment can sustain pilot response delays of up to 90 seconds and more, depending on the traffic density. However, when pilots or operators fail to respond to conflict alerts the safety effects are substantial, particularly at higher traffic densities.

  8. Automated Identification of Volcanic Plumes using the Ozone Monitoring Instrument (OMI)

    NASA Astrophysics Data System (ADS)

    Flower, V. J. B.; Oommen, T.; Carn, S. A.

    2015-12-01

    Volcanic eruptions are a global phenomenon which are increasingly impacting human populations due to factors such as the extension of population centres into areas of higher risk, expansion of agricultural sectors to accommodate increased production or the increasing impact of volcanic plumes on air travel. In areas where extensive monitoring is present these impacts can be moderated by ground based monitoring and alert systems, however many volcanoes have little or no monitoring capabilities. In many of these regions volcanic alerts are generated by local communities with limited resources or formal communication systems, however additional eruption alerts can result from chance encounters with passing aircraft. In contrast satellite based remote sensing instruments possess the capability to provide near global daily monitoring, facilitating automated volcanic eruption detection. One such system generates eruption alerts through the detection of thermal anomalies, known as MODVOLC, and is currently operational utilising moderate resolution MODIS satellite data. Within this work we outline a method to distinguish SO2 eruptions from background levels recorded by the Ozone Monitoring Instrument (OMI) through the identification and classification of volcanic activity over a 5 year period. The incorporation of this data into a logistic regression model facilitated the classification of volcanic events with an overall accuracy of 80% whilst consistently identifying plumes with a mass of 400 tons or higher. The implementation of the developed model could facilitate the near real time identification of new and ongoing volcanic activity on a global scale.

  9. The 2014 Mw 6.0 Napa Earthquake, California: Observations from Real-time GPS-enhanced Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Johanson, I. A.; Grapenthin, R.; Allen, R. M.

    2014-12-01

    Recently, progress has been made to demonstrate feasibility and benefits of including real-time GPS (rtGPS) in earthquake early warning and rapid response systems. While most concepts have yet to be integrated into operational environments, the Berkeley Seismological Laboratory is currently running an rtGPS based finite fault inversion scheme in true real-time, which is triggered by the seismic-based ShakeAlert system and then sends updated earthquake alerts to a test receiver. The Geodetic Alarm System (G-larmS) was online and responded to the 2014 Mw6.0 South Napa earthquake in California. We review G-larmS' performance during this event and for 13 aftershocks, and we present rtGPS observations and real-time modeling results for the main shock. The first distributed slip model and a magnitude estimate of Mw5.5 were available 24 s after the event origin time, which could be reduced to 14 s after a bug fix (~8 s S-wave travel time, ~6 s data latency). The system continued to re-estimate the magnitude once every second: it increased to Mw5.9 3 s after the first alert and stabilized at Mw5.8 after 15 s. G-larmS' solutions for the subsequent small magnitude aftershocks demonstrate that Mw~6.0 is the current limit for alert updates to contribute back to the seismic-based early warning system.

  10. Effects of historical and predictive information on ability of transport pilot to predict an alert

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    1994-01-01

    In the aviation community, the early detection of the development of a possible subsystem problem during a flight is potentially useful for increasing the safety of the flight. Commercial airlines are currently using twin-engine aircraft for extended transport operations over water, and the early detection of a possible problem might increase the flight crew's options for safely landing the aircraft. One method for decreasing the severity of a developing problem is to predict the behavior of the problem so that appropriate corrective actions can be taken. To investigate the pilots' ability to predict long-term events, a computer workstation experiment was conducted in which 18 airline pilots predicted the alert time (the time to an alert) using 3 different dial displays and 3 different parameter behavior complexity levels. The three dial displays were as follows: standard (resembling current aircraft round dial presentations); history (indicating the current value plus the value of the parameter 5 sec in the past); and predictive (indicating the current value plus the value of the parameter 5 sec into the future). The time profiles describing the behavior of the parameter consisted of constant rate-of-change profiles, decelerating profiles, and accelerating-then-decelerating profiles. Although the pilots indicated that they preferred the near term predictive dial, the objective data did not support its use. The objective data did show that the time profiles had the most significant effect on performance in estimating the time to an alert.

  11. CERN alerter—RSS based system for information broadcast to all CERN offices

    NASA Astrophysics Data System (ADS)

    Otto, R.

    2008-07-01

    Nearly every large organization uses a tool to broadcast messages and information across the internal campus (messages like alerts announcing interruption in services or just information about upcoming events). These tools typically allow administrators (operators) to send 'targeted' messages which are sent only to specific groups of users or computers, e/g only those located in a specified building or connected to a particular computing service. CERN has a long history of such tools: CERNVMS's SPM_quotMESSAGE command, Zephyr [2] and the most recent the NICE Alerter based on the NNTP protocol. The NICE Alerter used on all Windows-based computers had to be phased out as a consequence of phasing out NNTP at CERN. The new solution to broadcast information messages on the CERN campus continues to provide the service based on cross-platform technologies, hence minimizing custom developments and relying on commercial software as much as possible. The new system, called CERN Alerter, is based on RSS (Really Simple Syndication) [9] for the transport protocol and uses Microsoft SharePoint as the backend for database and posting interface. The windows-based client relies on Internet Explorer 7.0 with custom code to trigger the window pop-ups and the notifications for new events. Linux and Mac OS X clients could also rely on any RSS readers to subscribe to targeted notifications. The paper covers the architecture and implementation aspects of the new system.

  12. The effect of phasic auditory alerting on visual perception.

    PubMed

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas

    2017-08-01

    Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system-A survey of users.

    PubMed

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D

    2018-01-01

    Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.

  14. Efficient removal of Acid Green 25 dye from wastewater using activated Prunus Dulcis as biosorbent: Batch and column studies.

    PubMed

    Jain, Suyog N; Gogate, Parag R

    2018-03-15

    Biosorbent synthesized from dead leaves of Prunus Dulcis with chemical activation during the synthesis was applied for the removal of Acid Green 25 dye from wastewater. The obtained biosorbent was characterized using Brunauer-Emmett-Teller analysis, Fourier transform-infrared spectroscopy and scanning electron microscopy measurements. It was demonstrated that alkali treatment during the synthesis significantly increased surface area of biosorbent from 67.205 to 426.346 m 2 /g. The effect of various operating parameters on dye removal was investigated in batch operation and optimum values of parameters were established as pH of 2, 14 g/L as the dose of natural biosorbent and 6 g/L as the dose of alkali treated biosorbent. Relative error values were determined to check fitting of obtained data to the different kinetic and isotherm models. It was established that pseudo-second order kinetic model and Langmuir isotherm fitted suitably to the obtained batch experimental data. Maximum biosorption capacity values were estimated as 22.68 and 50.79 mg/g for natural biosorbent and for alkali activated Prunus Dulcis, respectively. Adsorption was observed as endothermic and activation energy of 6.22 kJ/mol confirmed physical type of adsorption. Column experiments were also conducted to probe the effectiveness of biosorbent for practical applications in continuous operation. Breakthrough parameters were established by studying the effect of biosorbent height, flow rate of dye solution and initial dye concentration on the extent of dye removal. The maximum biosorption capacity under optimized conditions in the column operation was estimated as 28.57 mg/g. Thomas and Yoon-Nelson models were found to be suitably fitted to obtained column data. Reusability study carried out in batch and continuous column operations confirmed that synthesized biosorbent can be used repeatedly for dye removal from wastewater. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youker, Amanda J.; Krebs, John F.; Quigley, Kevin J.

    With funding from the National Nuclear Security Administrations Material Management and Minimization Office, Argonne National Laboratory (Argonne) is providing technical assistance to help accelerate the U.S. production of Mo-99 using a non-highly enriched uranium (non-HEU) source. A potential Mo-99 production pathway is by accelerator-initiated fissioning in a subcritical uranyl sulfate solution containing low enriched uranium (LEU). As part of the Argonne development effort, we are undertaking the AMORE (Argonne Molybdenum Research Experiment) project, which is essentially a pilot facility for all phases of Mo-99 production, recovery, and purification. Production of Mo-99 and other fission products in the subcritical target solutionmore » is initiated by putting an electron beam on a depleted uranium (DU) target; the fast neutrons produced in the DU target are thermalized and lead to fissioning of U-235. At the end of irradiation, Mo is recovered from the target solution and separated from uranium and most of the fission products by using a titania column. The Mo is stripped from the column with an alkaline solution. After acidification of the Mo product solution from the recovery column, the Mo is concentrated (and further purified) in a second titania column. The strip solution from the concentration column is then purified with the LEU Modified Cintichem process. A full description of the process can be found elsewhere [1–3]. The initial commissioning steps for the AMORE project include performing a Mo-99 spike test with pH 1 sulfuric acid in the target vessel without a beam on the target to demonstrate the initial Mo separation-and-recovery process, followed by the concentration column process. All glovebox operations were tested with cold solutions prior to performing the Mo-99 spike tests. Two Mo-99 spike tests with pH 1 sulfuric acid have been performed to date. Figure 1 shows the flow diagram for the remotely operated Mo-recovery system for the AMORE project. There are two separate pumps and flow paths for the acid and base operations. The system contains three sample ladders with eight sample loops per ladder for target mixing; column loading, including acid and water washes; and column stripping, including the final water wash.« less

  16. Reducing duplicate testing: a comparison of two clinical decision support tools.

    PubMed

    Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert

    2015-05-01

    Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.

  17. A Southern California Perspective of the April, 1998 Trans-Pacific Asian Dust Event

    NASA Technical Reports Server (NTRS)

    Tratt, David M.; Frouin, Robert J.; Westphal, Douglas L.

    1999-01-01

    The Jet Propulsion Laboratory (JPL) coherent CO2 backscatter lidar has been in almost continuous operation since 1984 and has now accumulated a significant time-series database tracking the long-term and seasonal variability of backscatter from the atmospheric column above the Pasadena, Calif. locale. A particularly noteworthy episode observed by the lidar in 1998 was a particularly extreme instance of incursion by Asian-sourced dust during the closing days of April. Such events are not uncommon during the northern spring, when strong cold fronts and convection over the Asian interior deserts loft crustal material into the mid-troposphere whence it can be transported across the Pacific Ocean, occasionally reaching the continental US. However, the abnormal strength of the initiating storm in this case generated an atypically dense cloud of material which resulted in dramatically reduced visibility along the length of the Western Seaboard. These dust events are now recognized as a potentially significant, non-negligible radiative forcing influence. The progress of the April 1998 dust cloud eastward across the Pacific Ocean was initially observed in satellite imagery and transmitted to the broader atmospheric research community via electronic communications. The use of Internet technology in this way was effective in facilitating a rapid response correlative measurement exercise by numerous atmospheric observation stations throughout the western US and its success has resulted in the subsequent establishment of an ad hoc communications environment, data exchange medium, and mechanism for providing early-warning alert of other significant atmospheric phenomena in the future.

  18. The column density distribution of hard X-ray radio galaxies

    NASA Astrophysics Data System (ADS)

    Panessa, F.; Bassani, L.; Landi, R.; Bazzano, A.; Dallacasa, D.; La Franca, F.; Malizia, A.; Venturi, T.; Ubertini, P.

    2016-09-01

    In order to investigate the role of absorption in active galactic nuclei (AGN) with jets, we have studied the column density distribution of a hard X-ray selected sample of radio galaxies, derived from the INTEGRAL/Imager on Board the Integral Satellite (IBIS) and Swift/The Burst Alert Telescope (BAT) AGN catalogues (˜7-10 per cent of the total AGN population). The 64 radio galaxies have a typical FR II radio morphology and are characterized by high 20-100 keV luminosities (from 1042 to 1046 erg s-1) and high Eddington ratios (log LBol/LEdd typically larger than ˜0.01). The observed fraction of absorbed AGN (NH > 1022 cm-2) is around 40 per cent among the total sample, and ˜75 per cent among type 2 AGN. The majority of obscured AGN are narrow-line objects, while unobscured AGN are broad-line objects, obeying to the zeroth-order predictions of unified models. A significant anti-correlation between the radio core dominance parameter and the X-ray column density is found. The observed fraction of Compton thick AGN is ˜2-3 per cent, in comparison with the 5-7 per cent found in radio-quiet hard X-ray selected AGN. We have estimated the absorption and Compton thick fractions in a hard X-ray sample containing both radio galaxies and non-radio galaxies and therefore affected by the same selection biases. No statistical significant difference was found in the absorption properties of radio galaxies and non-radio galaxies sample. In particular, the Compton thick objects are likely missing in both samples and the fraction of obscured radio galaxies appears to decrease with luminosity as observed in hard X-ray non-radio galaxies.

  19. Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy

    DTIC Science & Technology

    2012-03-01

    for the consumer at the mo- ment but will soon become a commoditized, basic requirement. For example, as the baby boomers grow older, mobile services...Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy The WEA Project Team March 2012 SPECIAL REPORT CMU/SEI-2012-TR-019 CERT...report presents a taxonomy developed for the Commercial Mobile Alert Service (CMAS). The CMAS Alerting Pipeline Taxonomy is a hierarchical classification

  20. Wireless Emergency Alerts (WEA) Cybersecurity Risk Management Strategy for Alert Originators

    DTIC Science & Technology

    2014-03-01

    formerly known as the Commercial Mobile Alert Service ( CMAS ) RDT&E program, is a collaborative partnership that includes the cellular industry, the...Examples illustrate a STRIDE analysis of the generic mission 1 The CMAS Alerting Pipeline Taxonomy describes in detail a hierarchical classification...SEI-2013-SR-018 | 1 1 Introduction The Wireless Emergency Alerts (WEA) service, formerly known as the Commercial Mobile Alert Service ( CMAS ), is a

  1. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    PubMed

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  2. FFTFIL; a filtering program based on two-dimensional Fourier analysis of geophysical data

    USGS Publications Warehouse

    Hildenbrand, T.G.

    1983-01-01

    The filtering program 'fftfil' performs a variety of operations commonly required in geophysical studies of gravity, magnetic, and terrain data. Filtering operations are carried out in the wave number domain where the Fourier coefficients of the input data are multiplied by the response of the selected filter. Input grids can be large (2=number of rows or columns=1024) and are not required to have numbers of rows and columns equal to powers of two.

  3. Reduction in alert fatigue in an assisted electronic prescribing system, through the Lean Six Sigma methodology.

    PubMed

    Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis

    2017-01-01

    To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  4. Varying Levels of Automation on UAS Operator Responses to Traffic Resolution Advisories in Civil Airspace

    NASA Technical Reports Server (NTRS)

    Kenny, Caitlin; Fern, Lisa

    2012-01-01

    Continuing demand for the use of Unmanned Aircraft Systems (UAS) has put increasing pressure on operations in civil airspace. The need to fly UAS in the National Airspace System (NAS) in order to perform missions vital to national security and defense, emergency management, and science is increasing at a rapid pace. In order to ensure safe operations in the NAS, operators of unmanned aircraft, like those of manned aircraft, may be required to maintain separation assurance and avoid loss of separation with other aircraft while performing their mission tasks. This experiment investigated the effects of varying levels of automation on UAS operator performance and workload while responding to conflict resolution instructions provided by the Tactical Collision Avoidance System II (TCAS II) during a UAS mission in high-density airspace. The purpose of this study was not to investigate the safety of using TCAS II on UAS, but rather to examine the effect of automation on the ability of operators to respond to traffic collision alerts. Six licensed pilots were recruited to act as UAS operators for this study. Operators were instructed to follow a specified mission flight path, while maintaining radio contact with Air Traffic Control and responding to TCAS II resolution advisories. Operators flew four, 45 minute, experimental missions with four different levels of automation: Manual, Knobs, Management by Exception, and Fully Automated. All missions included TCAS II Resolution Advisories (RAs) that required operator attention and rerouting. Operator compliance and reaction time to RAs was measured, and post-run NASA-TLX ratings were collected to measure workload. Results showed significantly higher compliance rates, faster responses to TCAS II alerts, as well as less preemptive operator actions when higher levels of automation are implemented. Physical and Temporal ratings of workload were significantly higher in the Manual condition than in the Management by Exception and Fully Automated conditions.

  5. 76 FR 80780 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...

  6. A Pilot Study of a Novel Automated Somatosensory Evoked Potential (SSEP) Monitoring Device for Detection and Prevention of Intraoperative Peripheral Nerve Injury in Total Shoulder Arthroplasty Surgery.

    PubMed

    Chui, Jason; Murkin, John M; Drosdowech, Darren

    2018-05-21

    Peripheral nerve injury is a potentially devastating complication after total shoulder arthroplasty (TSA) surgery. This pilot study aimed to assess the feasibility of using an automated somatosensory evoked potential (SSEP) device to provide a timely alert/intervention to minimize intraoperative nerve insults during TSA surgery. A prospective, single-arm, observational study was conducted in a single university hospital. The attending anesthesiologist monitored the study participants using the EPAD automated SSEP device and an intervention was made if there was an alert during TSA surgery. The median, radial, and ulnar nerve SSEP on the operative arm, as well as the median nerve SSEP of the nonoperative arm were monitored for each patient. All patients were evaluated for postoperative neurological deficits 6 weeks postoperatively. In total, 21 patients were consented and were successfully monitored. In total, 4 (19%) patients developed intraoperative abnormal SSEP signal changes in the operative arm, in which 3 were reversible and 1 was irreversible till the end of surgery. Median and radial nerves were mostly involved (3/4 patients). The mean cumulative duration of nerve insult (abnormal SSEP) was 21.7±26.2 minutes. Univariate analysis did not identify predictor of intraoperative nerve insults. No patients demonstrated postoperative peripheral neuropathy at 6 weeks. A high incidence (19%) of intraoperative nerve insult was observed in this study demonstrating the feasibility of using an automated SSEP device to provide a timely alert and enable an intervention in order to minimize peripheral nerve injury during TSA. Further randomized studies are warranted.

  7. 77 FR 16147 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box... Transportation, Docket Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE... that note (f) of Figures 10 and 24 of Boeing Alert Service Bulletin 767-56A0010, Revision 1, dated...

  8. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  9. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  10. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  11. Evaluation of the operational and demonstration test of short-range weather forecasting decision support within an advanced rural traveler information system

    DOT National Transportation Integrated Search

    1996-11-01

    THIS IS THE TECHNICAL SUMMARY OF THE RESEARCH REPORT, COMMERCIAL MOTOR VEHICLE DRIVER FATIOUE AND ALERTNESS STUDY BY WYLIE ET AL., THE LARGEST AND MOST COMPREHENSIVE OVER-THE-ROAD STUDY ON THIS SUBJECT EVER CONDUCTED IN NORTH AMERICA. THE DATA COLLEC...

  12. Operational Test and Evaluation Handbook for Aircrew Training Devices. Volume I. Planning and Management.

    DTIC Science & Technology

    1982-02-01

    of i, nd to (! Lvel op an awareness of the T&E roles and responsioi Ii ties Viir~dte various Air Force organizations involved in the T&EC process... mathematical models to determine controller messages and issue controller messages using computer generated speech. AUTOMATED PERFORMANCE ALERTS: Signals

  13. Display area, looking north towards the classified storage rooms, D.M. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Display area, looking north towards the classified storage rooms, D.M. Logistics and D.O. Offices in northwest corner. Viewing bridge is at upper left, and alert status display at upper right - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  14. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  15. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  16. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  17. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  18. 47 CFR 80.1085 - Ship radio equipment-General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (channel 6), 156.650 MHz (channel 13), and 156.800 MHz (channel 16); (2) A dedicated, non-scanning radio... distress alert through the polar orbiting satellite service operating in the 406.0-406.1 MHz band (406.0.... Notice of new editions will be published on the Commission's Wireless Telecommunications Bureau web page...

  19. 47 CFR 80.1085 - Ship radio equipment-General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (channel 6), 156.650 MHz (channel 13), and 156.800 MHz (channel 16); (2) A dedicated, non-scanning radio... distress alert through the polar orbiting satellite service operating in the 406.0-406.1 MHz band (406.0.... Notice of new editions will be published on the Commission's Wireless Telecommunications Bureau web page...

  20. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... person may operate a turbine-powered airplane unless it is equipped with a ground proximity warning... system incorporates a Mode 4 flap warning inhibition control; and (2) An outline of all input sources... turbine-powered airplane unless it is equipped with a ground proximity warning/glide slope deviation...

  1. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... person may operate a turbine-powered airplane unless it is equipped with a ground proximity warning... system incorporates a Mode 4 flap warning inhibition control; and (2) An outline of all input sources... turbine-powered airplane unless it is equipped with a ground proximity warning/glide slope deviation...

  2. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  3. Department of Homeland Security: Assessments of Selected Complex Acquisitions

    DTIC Science & Technology

    2010-06-01

    10 The two nonmajor programs selected—the Biosurveillance Common...Management Directive AD 102-01, and approves acquisitions to proceed to their next acquisition life- cycle phases upon satisfaction of applicable ...programs are Biosurveillance Common Operating Network and the Integrated Public Alert and Warning System. BioWatch Generation-3 had not started

  4. 40 CFR 1033.112 - Emission diagnostics for SCR systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... diagnostic system must monitor reductant quality and tank levels and alert operators to the need to refill... specified in § 1033.110 and an audible alarm. You do not need to separately monitor reductant quality if you include an exhaust NOX sensor (or other sensor) that allows you to determine inadequate reductant quality...

  5. 40 CFR 1033.112 - Emission diagnostics for SCR systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... diagnostic system must monitor reductant quality and tank levels and alert operators to the need to refill... specified in § 1033.110 and an audible alarm. You do not need to separately monitor reductant quality if you include an exhaust NOX sensor (or other sensor) that allows you to determine inadequate reductant quality...

  6. 40 CFR 1033.112 - Emission diagnostics for SCR systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... diagnostic system must monitor reductant quality and tank levels and alert operators to the need to refill... specified in § 1033.110 and an audible alarm. You do not need to separately monitor reductant quality if you include an exhaust NOX sensor (or other sensor) that allows you to determine inadequate reductant quality...

  7. Decision Support from Genetic Algorithms for Ship Collision Avoidance Route Planning and Alerts

    NASA Astrophysics Data System (ADS)

    Tsou, Ming-Cheng; Kao, Sheng-Long; Su, Chien-Min

    When an officer of the watch (OOW) faces complicated marine traffic, a suitable decision support tool could be employed in support of collision avoidance decisions, to reduce the burden and greatly improve the safety of marine traffic. Decisions on routes to avoid collisions could also consider economy as well as safety. Through simulating the biological evolution model, this research adopts the genetic algorithm used in artificial intelligence to find a theoretically safety-critical recommendation for the shortest route of collision avoidance from an economic viewpoint, combining the international regulations for preventing collisions at sea (COLREGS) and the safety domain of a ship. Based on this recommendation, an optimal safe avoidance turning angle, navigation restoration time and navigational restoration angle will also be provided. A Geographic Information System (GIS) will be used as the platform for display and operation. In order to achieve advance notice of alerts and due preparation for collision avoidance, a Vessel Traffic Services (VTS) operator and the OOW can use this system as a reference to assess collision avoidance at present location.

  8. Experience and Grouping Effects when Handling Non-Normal Situations

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    2004-01-01

    Currently, most of the displays in control rooms can be categorized as status, alerts/procedures, or control screens. With the advent and use of CRTs and the associated computing power available to compute and display information, it is now possible to combine these different elements of information and control onto a single display. An experiment was conducted to determine which, if any, of these functions should be collocated in order to better handle simple anticipated non-normal system events. The results indicated that there are performance benefits and subject preferences to combining all the information onto one screen or combining the status and alert/procedure information onto one screen and placing the controls in another area. The results indicated that operators quickly modify their display preferences to the display configuration most recently used.

  9. Traffic Alert and Collision Avoidance System (TCAS): Cockpit Display of Traffic Information (CDTI) investigation. Phase 1: Feasibility study

    NASA Technical Reports Server (NTRS)

    Burgess, Malcolm; Davis, Dean; Hollister, Walter; Sorensen, John A.

    1991-01-01

    The possibility of the Threat Alert and Collision Avoidance System (TCAS) traffic sensor and display being used for meaningful Cockpit Display of Traffic Information (CDTI) applications has resulted in the Federal Aviation Administration initiating a project to establish the technical and operational requirements to realize this potential. Phase 1 of the project is presented here. Phase 1 was organized to define specific CDTI applications for the terminal area, to determine what has already been learned about CDTI technology relevant to these applications, and to define the engineering required to supply the remaining TCAS-CDTI technology for capacity benefit realization. The CDTI applications examined have been limited to those appropriate to the final approach and departure phases of flight.

  10. Usability Study of Two Collocated Prototype System Displays

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    2007-01-01

    Currently, most of the displays in control rooms can be categorized as status screens, alerts/procedures screens (or paper), or control screens (where the state of a component is changed by the operator). The primary focus of this line of research is to determine which pieces of information (status, alerts/procedures, and control) should be collocated. Two collocated displays were tested for ease of understanding in an automated desktop survey. This usability study was conducted as a prelude to a larger human-in-the-loop experiment in order to verify that the 2 new collocated displays were easy to learn and usable. The results indicate that while the DC display was preferred and yielded better performance than the MDO display, both collocated displays can be easily learned and used.

  11. NOAA Weather Wire Service

    Science.gov Websites

    & Imagery; includes NWS alerts and warnings No 6 Wireless Emergency Alerts (WEA) Mobile Phone Alerts & Warnings only No 7 Interactive NWS (iNWS) - NOTE 1 https://inws.ncep.noaa.gov/ Mobile Phone $$$$) Internet/ Mobile Phone Alerts and Warnings No 15 County or Local Emergency Management Telephone alert

  12. 75 FR 26196 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector... Special Fraud Alert. Specifically, the Updated Special Fraud Alert addressed the statutory provision...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...

  13. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    PubMed

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C; Quake, Stephen R; Burkholder, William F

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  14. Effect of the thermal environment on the efficiency of packed columns in supercritical fluid chromatography.

    PubMed

    Zauner, Jordan; Lusk, Ryan; Koski, Steven; Poe, Donald P

    2012-11-30

    When a packed column is operated at temperatures and pressures near the critical point in supercritical fluid chromatography, the thermal environment in which it is placed has a significant impact on retention and efficiency. We measured the retention factors, plate heights, and related parameters for elution of a test mixture of alkylbenzenes with 5% methanol/95% carbon dioxide mobile phase on a 250 mm × 4.6 mm i.d. column packed with 5-micron Luna-C18 particles. Separations were performed at outlet pressures from 100 to 150 bar and a column oven temperature of 323K. For a bare column thermostated with convective air, significant efficiency losses were observed for outlet pressures equal to or less than 120 bar. These large efficiency losses are attributed to radial temperature gradients. Addition of foam insulation resulted in significant improvements in efficiency. Operating the column in still air using a commercially available column heater provided the best overall performance, with no measurable efficiency loss over the entire range of pressures studied. A reduced plate height of 1.88 was obtained at an optimum flow rate of 3.0 mL/min at 100 bar outlet pressure and with the temperature of the incoming mobile phase set approximately 2.3K above the temperature of the column oven. Retention time repeatability for all three thermal conditions was equal to or less than 0.5% RSD. These results demonstrate that it is possible to perform fast, efficient separations with excellent repeatability using SFC under near-critical conditions if the thermal environment is optimized to minimize the generation of radial temperature gradients. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. A Microfluidic Device for Preparing Next Generation DNA Sequencing Libraries and for Automating Other Laboratory Protocols That Require One or More Column Chromatography Steps

    PubMed Central

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273

  16. Physician Perspectives of CYP2C19 and Clopidogrel Drug-Gene Interaction Active Clinical Decision Support Alerts

    PubMed Central

    Nishimura, Adam A.; Shirts, Brian H.; Salama, Joseph; Smith, Joe W.; Devine, Beth; Tarczy-Hornoch, Peter

    2015-01-01

    Objective To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. Materials and Methods 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Results Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Principal Conclusions Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. PMID:26642939

  17. Physician perspectives of CYP2C19 and clopidogrel drug-gene interaction active clinical decision support alerts.

    PubMed

    Nishimura, Adam A; Shirts, Brian H; Salama, Joseph; Smith, Joe W; Devine, Beth; Tarczy-Hornoch, Peter

    2016-02-01

    To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Contributors to Frequent Telehealth Alerts Including False Alerts for Patients with Heart Failure: A Mixed Methods Exploration

    PubMed Central

    Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.

    2013-01-01

    Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (p<0.05) of renal disorders, anxiety, and cardiac arrhythmias emerged as predictors of telehealth alerts through quantitative analysis (n = 168) using multiple regression. Inappropriate telehealth measurement technique by patients (54%) and home healthcare system inefficiencies (37%) contributed to most telehealth false alerts in the purposive qualitative sub-sample (n = 35) of patients with high telehealth alerts. Conclusion Encouraging patient engagement with the telehealth process, fostering a collaborative approach among all the clinicians involved with the telehealth intervention, tailoring telehealth alert thresholds to patient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576

  19. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system—A survey of users

    PubMed Central

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M.; Santen-Reestman, Jacqueline; Taxis, Katja

    2018-01-01

    Introduction Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. Objective To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. Methods In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Results Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. ‘Alert fatigue’ was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Conclusion Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue. PMID:29813099

  20. Primary Care Providers' Opening of Time-Sensitive Alerts Sent to Commercial Electronic Health Record InBaskets.

    PubMed

    Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S

    2017-11-01

    Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.

  1. Pilot evaluation of a method to assess prescribers' information processing of medication alerts.

    PubMed

    Russ, Alissa L; Melton, Brittany L; Daggy, Joanne K; Saleem, Jason J

    2017-02-01

    Prescribers commonly receive alerts during medication ordering. Prescribers work in a complex, time-pressured environment; to enhance the effectiveness of safety alerts, the effort needed to cognitively process these alerts should be minimized. Methods to evaluate the extent to which computerized alerts support prescribers' information processing are lacking. To develop a methodological protocol to assess the extent to which alerts support prescribers' information processing at-a-glance; specifically, the incorporation of information into their working memory. We hypothesized that the method would be feasible and that we would be able to detect a significant difference in prescribers' information processing with a revised alert display that incorporates warning design guidelines compared to the original alert display. A counterbalanced, within-subject study was conducted with 20 prescribers in a human-computer interaction laboratory. We tested a single alert that was displayed in two different ways. Prescribers were informed that an alert would appear for 10s. After the alert was shown, a white screen was displayed, and prescribers were asked to verbally describe what they saw; indicate how many total warnings; and describe anything else they remembered about the alert. We measured information processing via the accuracy of prescribers' free recall and their ability to identify that three warning messages were present. Two analysts independently evaluated participants' responses against a comprehensive catalog of alert elements and then discussed discrepancies until reaching consensus. This feasibility study demonstrated that the method seemed to be effective for evaluating prescribers' information processing of medication alert displays. With this method, we were able to detect significant differences in prescribers' recall of alert information. The proportion of total data elements that prescribers were able to accurately recall was significantly greater for the revised versus original alert display (p=0.006). With the revised display, more prescribers accurately reported that three warnings were shown (p=0.002). The methodological protocol was feasible for evaluating the alert display and yielded important findings on prescribers' information processing. Study methods supplement traditional usability evaluation methods and may be useful for evaluating information processing of other healthcare technologies. Published by Elsevier Inc.

  2. Flight Deck Display Technologies for 4DT and Surface Equivalent Visual Operations

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J., III; Jones, Denis R.; Shelton, Kevin J.; Arthur, Jarvis J., III; Bailey, Randall E.; Allamandola, Angela S.; Foyle, David C.; Hooey, Becky L.

    2009-01-01

    NASA research is focused on flight deck display technologies that may significantly enhance situation awareness, enable new operating concepts, and reduce the potential for incidents/accidents for terminal area and surface operations. The display technologies include surface map, head-up, and head-worn displays; 4DT guidance algorithms; synthetic and enhanced vision technologies; and terminal maneuvering area traffic conflict detection and alerting systems. This work is critical to ensure that the flight deck interface technologies and the role of the human participants can support the full realization of the Next Generation Air Transportation System (NextGen) and its novel operating concepts.

  3. Brain Behavior Evolution during Learning: Emergence of Hierarchical Temporal Memory

    DTIC Science & Technology

    2013-08-30

    organization and synapse strengthening and reconnection operating within and upon the existing processing structures[2]. To say the least, the brain is...that it is a tree increases, then we say its hierarchy in- creases. We explore different starting values and different thresholds and find that...impulses from two neuronal columns ( say i and k) to reach column j at the exact same time. This means when column j is analyzing whether or not to

  4. SEPARATION OF OCTYLPHENOL POLYETHER ALCOHOLS SURFACTANTS BY CAPILLARY COLUMN AND HPLC

    EPA Science Inventory

    Separation of nonionic octylphenol polyether alcohols (OPA) by supercritical fluid chromatography (SFC) and HPLC is described. sing a density programming and a 50-pm i.d. capillary column, a total of 18 group oligomers was separated. he effects of the operating parameters, such a...

  5. Evolution of a Simulation Testbed into an Operational Tool

    NASA Technical Reports Server (NTRS)

    Sheth, Kapil; Bilimoria, Karl D.; Sridhar, Banavar; Sterenchuk, Mike; Niznik, Tim; O'Neill, Tom; Clymer, Alexis; Gutierrez Nolasco, Sebastian; Edholm, Kaj; Shih, Fu-Tai

    2017-01-01

    This paper describes the evolution over a 20-year period of the Future ATM (Air Traffic Management) Concepts Evaluation Tool (FACET) from a National Airspace System (NAS) based simulation testbed into an operational tool. FACET was developed as a testbed for assessing futuristic ATM concepts, e.g., automated conflict detection and resolution. NAS Constraint Evaluation and Notification Tool (NASCENT) is an application, within FACET, for alerting airspace users of inefficiencies in flight operations and advising time- and fuel-saving reroutes.It is currently in use at American Airlines Integrated Operations Center in Fort Worth, TX. The concepts assessed,research conducted, and the operational capability developed, along with the NASA support and achievements are presented in this paper.

  6. Oak Ridge Reservation Public Warning Siren System Annual Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. F. Gee

    2000-10-01

    The full operational test of the Oak Ridge Reservation (ORR) Public Warning Siren System (PWSS) was successfully conducted on September 27, 2000. The annual test is a full-scale sounding of the individual siren systems around each of the three Department of Energy (DOE) sites in Oak Ridge, Tennessee. The purpose of the annual test is to demonstrate and validate the siren systems' ability to alert personnel outdoors in the Immediate Notification Zones (INZ) (approximately two miles) around each site. The success of this test is based on two critical functions of the siren system. The first function is system operability.more » The system is considered operable if 90% of the sirens are operational. System diagnostics and direct field observations were used to validate the operability of the siren systems. Based on the diagnostic results and field observations, greater than 90% of the sirens were considered operational. The second function is system audibility. The system is considered audible if the siren could be heard in the immediate notification zones around each of the three sites. Direct field observations, along with sound level measurements, were used to validate the audibility of the siren system. Based on the direct field observations and sound level measurements, the siren system was considered audible. The combination of field observations, system diagnostic status reports, and sound level measurements provided a high level of confidence that the system met and would meet operational requirements upon demand. As part of the overall system test, the Tennessee Emergency Management Agency (TEMA) activated the Emergency Alerting System (EAS), which utilized area radio stations to make announcements regarding the test and to remind residents of what to do in the event of an actual emergency.« less

  7. A Near-Term Concept for Trajectory Based Operations with Air/Ground Data Link Communication

    NASA Technical Reports Server (NTRS)

    McNally, David; Mueller, Eric; Thipphavong, David; Paielli, Russell; Cheng, Jinn-Hwei; Lee, Chuhan; Sahlman, Scott; Walton, Joe

    2010-01-01

    An operating concept and required system components for trajectory-based operations with air/ground data link for today's en route and transition airspace is proposed. Controllers are fully responsible for separation as they are today, and no new aircraft equipage is required. Trajectory automation computes integrated solutions to problems like metering, weather avoidance, traffic conflicts and the desire to find and fly more time/fuel efficient flight trajectories. A common ground-based system supports all levels of aircraft equipage and performance including those equipped and not equipped for data link. User interface functions for the radar controller's display make trajectory-based clearance advisories easy to visualize, modify if necessary, and implement. Laboratory simulations (without human operators) were conducted to test integrated operation of selected system components with uncertainty modeling. Results are based on 102 hours of Fort Worth Center traffic recordings involving over 37,000 individual flights. The presence of uncertainty had a marginal effect (5%) on minimum-delay conflict resolution performance, and windfavorable routes had no effect on detection and resolution metrics. Flight plan amendments and clearances were substantially reduced compared to today s operations. Top-of-descent prediction errors are the largest cause of failure indicating that better descent predictions are needed to reliably achieve fuel-efficient descent profiles in medium to heavy traffic. Improved conflict detections for climbing flights could enable substantially more continuous climbs to cruise altitude. Unlike today s Conflict Alert, tactical automation must alert when an altitude amendment is entered, but before the aircraft starts the maneuver. In every other failure case tactical automation prevented losses of separation. A real-time prototype trajectory trajectory-automation system is running now and could be made ready for operational testing at an en route Center in 1-2 years.

  8. Piloted "Well Clear" Performance Evaluation of Detect-and-Avoid Systems with Suggestive Guidance

    NASA Technical Reports Server (NTRS)

    Mueller, Eric R.; Santiago, Confesor; Watza, Spencer

    2016-01-01

    This study evaluated the performance of four prototype unmanned aircraft detect-and-avoid (DAA) display configurations, each with different informational elements driven by alerting and guidance algorithms. Sixteen unmanned aircraft pilots flew each combination of the display configurations, with half being given zero DAA surveillance sensor uncertainty and the other half experiencing errors that were comparable, and in some cases slightly better than, errors that were measured in DAA system flight tests. The displays that showed intruder alert information in altitude and heading bands had significantly fewer losses of well clear compared with alternative displays that lacked that information. This difference was significant from a statistical and practical perspective: those losses that did occur lasted for shorter periods and did not penetrate as far into the geometric "separation cylinder" as those in the non-banded displays. A modest level of DAA surveillance sensor uncertainty did not affect the proportion of losses of well clear or their severity. It is recommended that DAA traffic displays implement a band-type display in order to improve the safety of UAS operations in the National Airspace System. Finally, this report provides pilot response time distributions for responding to DAA alerts.

  9. A Holding Function for Conflict Probe Appiications

    NASA Technical Reports Server (NTRS)

    McNally, Dave; Walton, Joe

    2004-01-01

    Conflict Alerts for aircraft in holding patterns are often missed or in error due to fact that holding trajectories are not modeled in Conflict Alert or Conflict Probe logic. In addition, a controller in one sector may not know when aircraft are holding in a neighboring sector. These factors can lead to an increased potential for loss of separation while aircraft are flying in holding patterns. A holding function for conflict probe applications has been developed and tested with air traffic data from Fort Worth Center. The holding function automatically determines when an aircraft enters a holding pattern, builds a holding region around the pattern and then probes the region for conflict with other traffic. The operational concept of use assumes that air traffic controllers are very busy during periods when aircraft are in holding and therefore don't have time to manually enter information which defines a holding pattern and activates conflict probing. For this reason, it is important the holding function automatically detect aircraft in holding and compute a holding region for conflict analysis. The controller is then alerted if other aircraft are predicted to fly through the holding region at the holding altitude.

  10. Pilot Interactions in an Over-Constrained Conflict Scenario as Studied in a Piloted Simulation of Autonomous Aircraft Operations

    NASA Technical Reports Server (NTRS)

    Wing, David J.; Barhydt, Richard; Barmore, Bryan; Krishnamurthy, Karthik

    2003-01-01

    Feasibility and safety of autonomous aircraft operations were studied in a multi-piloted simulation of overconstrained traffic conflicts to determine the need for, and utility of, priority flight rules to maintain safety in this extraordinary and potentially hazardous situation. An overconstrained traffic conflict is one in which the separation assurance objective is incompatible with other objectives. In addition, a proposed scheme for implementing priority flight rules by staggering the alerting time between the two aircraft in conflict was tested for effectiveness. The feasibility study was conducted through a simulation in the Air Traffic Operations Laboratory at the NASA Langley Research Center. This research activity is a continuation of the Distributed Air-Ground Traffic Management feasibility analysis reported in the 4th USA/Europe Air Traffic Management R&D Seminar in December 2001 (paper #48). The over-constrained conflict scenario studied here consisted of two piloted aircraft that were assigned an identical en-route waypoint arrival time and altitude crossing restriction. The simulation results indicated that the pilots safely resolved the conflict without the need for a priority flight rule system. Occurrences of unnecessary maneuvering near the common waypoint were traced to false conflict alerts, generated as the result of including waypoint constraint information in the broadcast data link message issued from each aircraft. This result suggests that, in the conservative interests of safety, broadcast intent information should be based on the commanded trajectory and not on the Flight Management System flight plan, to which the aircraft may not actually adhere. The use of priority flight rules had no effect on the percentage of the aircraft population meeting completely predictable which aircraft in a given pair would meet the constraints and which aircraft would make the first maneuver to yield right-of-way. Therefore, the proposed scheme for implementing priority flight rules through staggering the alerting time between the two aircraft was completely effective. The data and observations from this experiment, together with results from the previously reported study, support the feasibility of autonomous aircraft operations.

  11. Computerized Dose Range Checking Using Hard and Soft Stop Alerts Reduces Prescribing Errors in a Pediatric Intensive Care Unit.

    PubMed

    Balasuriya, Lilanthi; Vyles, David; Bakerman, Paul; Holton, Vanessa; Vaidya, Vinay; Garcia-Filion, Pamela; Westdorp, Joan; Sanchez, Christine; Kurz, Rhonda

    2017-09-01

    An enhanced dose range checking (DRC) system was developed to evaluate prescription error rates in the pediatric intensive care unit and the pediatric cardiovascular intensive care unit. An enhanced DRC system incorporating "soft" and "hard" alerts was designed and implemented. Practitioner responses to alerts for patients admitted to the pediatric intensive care unit and the pediatric cardiovascular intensive care unit were retrospectively reviewed. Alert rates increased from 0.3% to 3.4% after "go-live" (P < 0.001). Before go-live, all alerts were soft alerts. In the period after go-live, 68% of alerts were soft alerts and 32% were hard alerts. Before go-live, providers reduced doses only 1 time for every 10 dose alerts. After implementation of the enhanced computerized physician order entry system, the practitioners responded to soft alerts by reducing doses to more appropriate levels in 24.7% of orders (70/283), compared with 10% (3/30) before go-live (P = 0.0701). The practitioners deleted orders in 9.5% of cases (27/283) after implementation of the enhanced DRC system, as compared with no cancelled orders before go-live (P = 0.0774). Medication orders that triggered a soft alert were submitted unmodified in 65.7% (186/283) as compared with 90% (27/30) of orders before go-live (P = 0.0067). After go-live, 28.7% of hard alerts resulted in a reduced dose, 64% resulted in a cancelled order, and 7.4% were submitted as written. Before go-live, alerts were often clinically irrelevant. After go-live, there was a statistically significant decrease in orders that were submitted unmodified and an increase in the number of orders that were reduced or cancelled.

  12. Selective impairment of attention networks during propofol anesthesia after gynecological surgery in middle-aged women.

    PubMed

    Chen, Chen; Xu, Guang-hong; Li, Yuan-hai; Tang, Wei-xiang; Wang, Kai

    2016-04-15

    Postoperative cognitive dysfunction is a common complication of anesthesia and surgery. Attention networks are essential components of cognitive function and are subject to impairment after anesthesia and surgery. It is not known whether such impairment represents a global attention deficit or relates to a specific attention network. We used an Attention Network Task (ANT) to examine the efficiency of the alerting, orienting, and executive control attention networks in middle-aged women (40-60 years) undergoing gynecologic surgery. A matched group of medical inpatients were recruited as a control. Fifty female patients undergoing gynecologic surgery (observation group) and 50 female medical inpatients (control group) participated in this study. Preoperatively patients were administered a mini-mental state examination as a screening method. The preoperative efficiencies of three attention networks in an attention network test were compared to the 1st and 5th post-operative days. The control group did not have any significant attention network impairments. On the 1st postoperative day, significant impairment was shown in the alerting (p=0.003 vs. control group, p=0.015 vs. baseline), orienting (p<0.001 vs. both baseline level and control group), and executive control networks (p=0.007 vs. control group, p=0.002 vs. baseline) of the observation group. By the 5th postoperative day, the alerting network efficiency had recovered to preoperative levels (p=0.464 vs. baseline) and the orienting network efficiency had recovered partially (p=0.031 vs. 1st post-operative day), but not to preoperative levels (p=0.01 vs. baseline). The executive control network did not recover by the 5th postoperative day (p=0.001 vs. baseline, p=0.680 vs. 1st post-operative day). Attention networks of middle-aged women show a varying degree of significant impairment and differing levels of recovery after surgery and propofol anesthetic. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Hemochromatosis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. Bronchiectasis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Tracheostomy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Palpitations

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. Thalassemias

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. Cardioversion

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. Introduction to the JAWS Program

    NASA Technical Reports Server (NTRS)

    Mccarthy, John

    1987-01-01

    The JAWS Project is the Joint Airport Weather Studies project conceived in 1980 jointly between the National Center for Atmospheric Research and the Univ. of Chicago. The objectives of the program are threefold: (1) Basic scientific characterization of the microbursts and the statistics of microbursts occurrence; (2) Detection and warning, using the Low Level Wind Shear Alert System (LLWSAS) operation and performance; and (3) Doppler radar and airborne systems. These goals and the operation of the JAWS system in general are discussed in detail.

  20. A Double-Blind Placebo-Controlled Investigation of the Efficacy of Modafinil for Maintaining Alertness and Performance in Sustained Military Ground Operations

    DTIC Science & Technology

    2006-08-01

    Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be...Heintz, Hickey, Hurtle, Kisner, and Smith, 2004). The dosing scheme used in the current study was similar to schemes recommended by Buguet, Moroz ...Psychomotor and Cognitive Impairment Induced by Sleep- deprivation in 12 Healthy Volunteers. European Psychiatry, 6(2), 93-97. 4. Buguet, A., Moroz , D., and

  1. Minuteman III Cost Per Alert Hour Analysis

    DTIC Science & Technology

    2012-03-22

    Proverbs 16:3 I am eternally grateful for such a lovely wife and vibrant children; without your patience and support, I would...section. 12 Table 1: Alternative CPFH Factors H ild eb ra nt (1 99 0) W al la ce (2 00 0) Ki le y (2 00 1) Py le s (2 00 3) La ub ac he r (2 00 4...Installation Law Enforcement ( LE ) Operations. Installation LE Operations includes enforcing federal, state and military law, enforcing installation

  2. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  3. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  4. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  5. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...

  6. Lung Transplant

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  7. Carotid Endarterectomy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  8. Pulmonary Embolism

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  9. Pernicious Anemia

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  10. Catheter Ablation

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. Immune Thrombocytopenia

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  12. Chest MRI

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  13. Cardiac Rehabilitation

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. Cardiac MRI

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Oxygen Therapy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Detecting alerts, notifying the physician, and offering action items: a comprehensive alerting system.

    PubMed Central

    Kuperman, G. J.; Teich, J. M.; Bates, D. W.; Hiltz, F. L.; Hurley, J. M.; Lee, R. Y.; Paterno, M. D.

    1996-01-01

    We developed and evaluated a system to automatically identify serious clinical conditions in inpatients. The system notifies the patient's covering physician via his pager that an alert is present and offers potential therapies for the patient's condition (action items) at the time he views the alert information. Over a 6 month period, physicians responded to 1214 (70.2%) of 1730 alerts for which they were paged; they responded to 1002 (82.5% of the 1214) in less than 15 minutes. They said they would take action in 71.5% of the alerts, and they placed an order directly from the alert display screen in 39.4%. Further study is needed to determine if this alerting system improves processes or outcomes of care. PMID:8947756

  17. Revealing the functional neuroanatomy of intrinsic alertness using fMRI: methodological peculiarities.

    PubMed

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander T; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that--as a methodological artifact--left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies.

  18. Revealing the Functional Neuroanatomy of Intrinsic Alertness Using fMRI: Methodological Peculiarities

    PubMed Central

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that – as a methodological artifact – left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies. PMID:21984928

  19. ToxAlerts: a Web server of structural alerts for toxic chemicals and compounds with potential adverse reactions.

    PubMed

    Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V

    2012-08-27

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing.

  20. ToxAlerts: A Web Server of Structural Alerts for Toxic Chemicals and Compounds with Potential Adverse Reactions

    PubMed Central

    2012-01-01

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing. PMID:22876798

  1. Detection of Mental State and Reduction of Artifacts Using Functional Near Infrared Spectroscopy (FNIRS)

    NASA Technical Reports Server (NTRS)

    Harrivel, Angela (Inventor); Hearn, Tristan (Inventor)

    2017-01-01

    fNIRS may be used in real time or near-real time to detect the mental state of individuals. Phase measurement can be applied to drive an adaptive filter for the removal of motion artifacts in real time or near-real time. In this manner, the application of fNIRS may be extended to practical non-laboratory environments. For example, the mental state of an operator of a vehicle may be monitored, and alerts may be issued and/or an autopilot may be engaged when the mental state of the operator indicates that the operator is inattentive.

  2. Alert status of nuclear weapons

    NASA Astrophysics Data System (ADS)

    Kristensen, Hans M.

    2017-11-01

    Nuclear Alert Forces. Four nuclear-armed states deploy nuclear warheads on alert, ready to be used on relatively short notice: United States, Russia, France and Britain. Combined, the four countries deploy an estimated 1,869 nuclear alert warheads. Russia and the United States deploy 1,749 alert warheads combined, or 94% of all alert warheads. Despite some debate about possible need to increase readiness of nuclear forces (China, Pakistan), the five other nuclear-armed states (China, Pakistan, India, Israel and North Korea) are thought to store their warheads separate from launchers under normal circumstances. The overall number of alert warheads has remained relatively stable during the past five years.

  3. Geo-targeted Weather Alerts Coming to Millions of Mobile Devices

    NASA Astrophysics Data System (ADS)

    Gerber, M.

    2011-12-01

    The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.

  4. SEPARATION OF OCTYLPHENOL POLYETHER ALCOHOLS SURFACTANTS BY CAPILLARY COLUMN SFC AND HPLC

    EPA Science Inventory

    Separation of nonionic octylphenol polyether alcohols (OPA) by supercritical fluid chromatography (SFC) and HPLC is described. Using a density programming and a 50-μm i.d. capillary column, a total of 18 group oligomers was separated. The effects of the operating parameters, such...

  5. Automated External Defibrillator

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  6. Thrombocythemia and Thrombocytosis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  7. von Willebrand Disease

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  8. Chest X-Ray

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  9. What Is Cardiomyopathy?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  10. Long QT Syndrome

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. Percutaneous Coronary Intervention

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  12. What is Hemophilia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  13. Thrombotic Thrombocytopenic Purpura

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. What Is Anemia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Cardiac CT Scan

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Coronary Calcium Scan

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. Patent Ductus Arteriosus

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. What is Bronchoscopy?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.

    PubMed

    Abe, Andrew M; Hein, Darren J; Gregory, Philip J

    2015-06-01

    Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  20. The handedness of historiated spiral columns.

    PubMed

    Couzin, Robert

    2017-09-01

    Trajan's Column in Rome (AD 113) was the model for a modest number of other spiral columns decorated with figural, narrative imagery from antiquity to the present day. Most of these wind upwards to the right, often with a congruent spiral staircase within. A brief introductory consideration of antique screw direction in mechanical devices and fluted columns suggests that the former may have been affected by the handedness of designers and the latter by a preference for symmetry. However, for the historiated columns that are the main focus of this article, the determining factor was likely script direction. The manner in which this operated is considered, as well as competing mechanisms that might explain exceptions. A related phenomenon is the reversal of the spiral in a non-trivial number of reproductions of the antique columns, from Roman coinage to Renaissance and baroque drawings and engravings. Finally, the consistent inattention in academic literature to the spiral direction of historiated columns and the repeated publication of erroneous earlier reproductions warrants further consideration.

Top