Science.gov

Sample records for alert system agency

  1. Jetliner Alert Systems

    NASA Technical Reports Server (NTRS)

    1983-01-01

    NASA research and design has significantly improved crew alert systems. The Engine Indication and Crew Alerting System (EICAS), developed by Psycho-Linguistic Research Associates, is technologically advanced and able to order alerts by priority. Ames has also developed computer controlled voice synthesizers for readouts during difficult landing approaches. This is available to airplane manufacturers.

  2. Visual Alert System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.

  3. 77 FR 41331 - Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... COMMISSION 47 CFR Part 10 Commercial Mobile Alert System AGENCY: Federal Communications Commission. ACTION... collection requirements associated with the Commission's Commercial Mobile Alert System (CMS), Second Report... relating to the Commercial Mobile Alert System rules contained in the Commission's Second Report and...

  4. The COMESEP Alert System

    NASA Astrophysics Data System (ADS)

    Crosby, Norma; Veronig, Astrid; Rodriguez, Luciano; Vrsnak, Bojan; Vennerstrom, Susanne; Malandraki, Olga; Dalla, Silvia; Srivastava, Nandita; Hesse, Michael; Odstrcil, Dusan; Robbrecht, Eva

    2014-05-01

    Tools for forecasting geomagnetic storms and solar energetic particle (SEP) radiation storms have been developed under the three-year EU FP7 COMESEP (COronal Mass Ejections and Solar Energetic Particles) collaborative project. To enhance our understanding of the 3D kinematics and interplanetary propagation of coronal mass ejections (CMEs), the structure, propagation and evolution of CMEs have been investigated. In parallel, the sources and propagation of SEPs have been examined and modeled. During the third year of the COMESEP project the produced tools have been validated and implemented into an operational space weather alert system. The COMESEP Alert System provides notifications for the space weather community. To achieve this the system relies on both models and data, the latter including near real-time data as well as historical data. Geomagnetic and SEP radiation storm alerts are based on the COMESEP definition of risk. The COMESEP Alert System has recently been launched. Receiving COMESEP alerts are free of charge, but registration is required. For more information see the project website (http://www.comesep.eu/). This work has received funding from the European Commission FP7 Project COMESEP (263252).

  5. 77 FR 16688 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-22

    ... COMMISSION 47 CFR Part 11 Review of the Emergency Alert System AGENCY: Federal Communications Commission... its rules governing the Emergency Alert System (EAS) to codify the obligation to process alert... Commission adopts several changes to its Part 11 Emergency Alert System (EAS) rules to more fully codify...

  6. 78 FR 16806 - The Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-19

    ... COMMISSION 47 CFR Part 10 The Commercial Mobile Alert System AGENCY: Federal Communications Commission... Commercial Mobile Alert System (CMAS) to Wireless Emergency Alerts (WEA). This is intended to conform the name used for the wireless alert system regulated under Commission rules to the name used by the...

  7. 76 FR 35810 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-20

    ... Docket No. 04-296; FCC 11-82] Review of the Emergency Alert System AGENCY: Federal Communications... Commission (Commission) seeks comment on proposed changes to its rules governing the Emergency Alert System (EAS) to codify the obligation to process alert messages formatted in the Common Alerting Protocol...

  8. 76 FR 80780 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... COMMISSION 47 CFR Part 11 Review of the Emergency Alert System AGENCY: Federal Communications Commission... Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to no later than June 30, 2012. This is intended to...

  9. 76 FR 62321 - Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-07

    ... Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) Units AGENCY... certain Aviation Communication & Surveillance Systems (ACSS) traffic alert and collision avoidance system...) traffic alert and collision avoidance system (TCAS) units with part numbers identified in ACSS...

  10. 77 FR 33661 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-07

    ... COMMISSION 47 CFR Part 11 Review of the Emergency Alert System AGENCY: Federal Communications Commission... information collection associated with the Commission's Review of the Emergency Alert System, Fifth Report and...--Emergency Alert System, Fifth Report and Order, FCC 12-7. Form Number: N/A. Respondents: Business or...

  11. 75 FR 4760 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-29

    ... COMMISSION 47 CFR Part 11 Review of the Emergency Alert System AGENCY: Federal Communications Commission... seeking comment on its proposal to amend the Commission's rules governing the Emergency Alert System (EAS... issue a national alert. DATES: Comments are due on or before March 1, 2010 and reply comments are due...

  12. 77 FR 26701 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... COMMISSION 47 CFR Part 11 Review of the Emergency Alert System AGENCY: Federal Communications Commission... its rules governing the Emergency Alert System (EAS) rules so that EAS Participants may, but are not... adopted rules specifying the manner in which EAS Participants must be able to receive alert...

  13. 76 FR 12600 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ... COMMISSION 47 CFR Part 11 Review of the Emergency Alert System AGENCY: Federal Communications Commission... its rules governing the Emergency Alert System (EAS) to provide for national EAS testing and... a national Presidential alert. DATES: Effective March 8, 2011. FOR FURTHER INFORMATION CONTACT:...

  14. Alert Notification System Router

    NASA Technical Reports Server (NTRS)

    Gurganus, Joseph; Carey, Everett; Antonucci, Robert; Hitchener, Peter

    2009-01-01

    The Alert Notification System Router (ANSR) software provides satellite operators with notifications of key events through pagers, cell phones, and e-mail. Written in Java, this application is specifically designed to meet the mission-critical standards for mission operations while operating on a variety of hardware environments. ANSR is a software component that runs inside the Mission Operations Center (MOC). It connects to the mission's message bus using the GMSEC [Goddard Space Flight Center (GSFC) Mission Services Evolution Center (GMSEC)] standard. Other components, such as automation and monitoring components, can use ANSR to send directives to notify users or groups. The ANSR system, in addition to notifying users, can check for message acknowledgements from a user and escalate the notification to another user if there is no acknowledgement. When a firewall prevents ANSR from accessing the Internet directly, proxies can be run on the other side of the wall. These proxies can be configured to access the Internet, notify users, and poll for their responses. Multiple ANSRs can be run in parallel, providing a seamless failover capability in the event that one ANSR system becomes incapacitated.

  15. Solar Radiation Alert System

    DTIC Science & Technology

    2009-03-01

    th an effectve cutoff rgdty of ~0 MV (2)), the FAA’s Cvl Aerospace Medcal Insttute (CAMI) ssues a Solar Radaton Alert (SRA) to the Nat...fluences of other partcles are too small to be of sgnficance n dose calculatons (4, 11). Earth was modeled as a sphere of lqud water of rad

  16. 78 FR 53774 - Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-30

    ... SECURITY Federal Emergency Management Agency Guide for the Evaluation of Alert and Notification Systems for... Agency (FEMA) requests public comments on the Guide for the Evaluation of Alert and Notification Systems... Management Agency (FEMA) issued FEMA-REP-10, Guide for the Evaluation of Alert and Notification Systems...

  17. Emergency vehicle alert system (EVAS)

    NASA Technical Reports Server (NTRS)

    Reed, Bill; Crump, Roger; Harper, Warren; Myneni, Krishna

    1995-01-01

    The Emergency Vehicle Alert System (EVAS) program is sponsored by the NASA/MSFC Technology Utilization (TU) office. The program was conceived to support the needs of hearing impaired drivers. The objective of the program is to develop a low-cost, small device which can be located in a personal vehicle and warn the driver, via a visual means, of the approach of an emergency vehicle. Many different technologies might be developed for this purpose and each has its own advantages and drawbacks. The requirements for an acoustic detection system, appear to be pretty stringent and may not allow the development of a reliable, low-cost device in the near future. The problems include variations in the sirens between various types of emergency vehicles, distortions due to wind and surrounding objects, competing background noise, sophisticated signal processing requirements, and omni-directional coverage requirements. Another approach is to use a Radio Frequency (RF) signal between the Emergency Vehicle (EV) and the Personal Vehicle (PV). This approach requires a transmitter on each EV and a receiver in each PV, however it is virtually assured that a system can be developed which works. With this approach, the real technology issue is how to make a system work as inexpensively as possible. This report gives a brief summary of the EVAS program from its inception and concentrates on describing the activities that occurred during Phase 4. References 1-3 describe activities under Phases 1-3. In the fourth phase of the program, the major effort to be expended was in development of the microcontroller system for the PV, refinement of some system elements and packaging for demonstration purposes. An EVAS system was developed and demonstrated which used standard spread spectrum modems with minor modifications.

  18. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an...

  19. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an...

  20. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an...

  1. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an...

  2. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an...

  3. Auditory alert systems with enhanced detectability

    NASA Technical Reports Server (NTRS)

    Begault, Durand R. (Inventor)

    2008-01-01

    Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

  4. Aircraft Alerting Systems Criteria Study. Volume 1. Collation and Analysis of Aircraft Alerting Systems Data

    DTIC Science & Technology

    1977-05-01

    and ()provide recommendations for standardization of alerting functions/ methods. The output includes a collation of human factors data pertinent to...alerting sys- tems, cursory test plans for obtaining missing human factors data required to complete definition of and validate the standards...Warning, Warning Systems, Dlocument is available to the U,S. . * Stimulus Response, Human Factors Alerting public through the National Technical Systems

  5. An Operational Alert System for the European-Mediterranean Region

    NASA Astrophysics Data System (ADS)

    Mazet-Roux, G.; Bossu, R.; Carreno, E.; Guilbert, J.; Godey, S.

    2003-12-01

    The European-Mediterranean Seismological Centre (EMSC) has been running for several years an operational alert system for potentially damaging earthquakes which occur in the European-Mediterranean region. This alert system, - sub-part of the EMSC real time information service available on the web site (www.emsc-csem.org) - is based on parametric data provided through the Internet by 40 different networks representing 800 stations in the Euro.-Med. region. In case of potentially damaging earthquake, the seismologist on duty connects to EMSC facilities, merges and processes all available data and, as soon as a reliable solution is available, disseminates alert messages by fax and email. Alert messages are sent by fax to official organisations (e.g., Civil Protection Agency, rescue teams, Council of Europe, ECHO, etc.), to the seismological community and to the public by emails (800 emails). Furthermore, data and results are made automatically available in real time on the web. In case of technical problems or maintenance activities, the duty is taken over by IGN (Madrid, Spain), which runs full back-up procedures. EMSC commits itself to a maximum dissemination time (time lag between the occurrence of the earthquake and the messages' dissemination) of 1 hour. This delay is respected in the vast majority of cases with a median dissemination time of less than 40 minutes. We will give an overview of this system and its performances and put a special emphasis on the processing of the recent earthquake in Algeria.

  6. Rapid deployable global sensing hazard alert system

    DOEpatents

    Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M

    2015-04-28

    A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.

  7. Alert generation and cockpit presentation for an integrated microburst alerting system

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Hansman, R. John, Jr.

    1991-01-01

    Alert generation and cockpit presentation issues for low level wind shear (microburst) alerts are investigated. Alert generation issues center on the development of a hazard criterion which allows integration of both ground based and airborne wind shear detection systems to form an accurate picture of the aviation hazard posed by a particular wind shear situation. A methodology for the testing of a hazard criteria through flight simulation has been developed, and has been used to examine the effectiveness and feasibility of several possible criteria. Also, an experiment to evaluate candidate graphical cockpit displays for microburst alerts using a piloted simulator has been designed.

  8. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the...

  9. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the...

  10. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the...

  11. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the...

  12. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the...

  13. The Seismic Alert System of Mexico and their automatic Alert Signals broadcast improvements

    NASA Astrophysics Data System (ADS)

    Espinosa Aranda, J.; Cuellar Martinez, A.; Garcia, A.; Ibarrola, G.; Islas, R.; Maldonado, S.

    2009-12-01

    The Mexican Seismic Alert System (SASMEX), is integrated by the Seismic Alert System of Mexico City (SAS), in continuous operation since 1991, and the Seismic Alert System of Oaxaca City (SASO) that started its service in 2003. The SAS generates automatic broadcast of Public and Preventive Alert Signals to the cities of Mexico, Toluca, Acapulco and Chilpancingo, and SASO by now only to Oaxaca City. Two types of SASMEX Seismic Alert Signal ranges were determinated in accordance with each local Civil Protection Authorities: Public Alert if they expect strong earthquake effects and Preventive Alert Signal, for moderated once. SAS has 12 field sensor stations covering partial segment of the Guerrero coast, and the SASO has 35 field sensor stations operating in the coast, central and north of the Oaxaca, covering the seismic danger territory. Since 1993, the SAS is pioneer in the automatic public alert broadcast services, thanks to the support of the Asociación de Radiodifusores del Valle de México, A.C. (ARVM). Historically in Mexico City, due to their great distance to the coast of Guerrero, the SAS has been issued its Alert Signals with an opportunity average of 60 seconds. In Oaxaca City the SASO gives 30 seconds time opportunity, if the earthquake detected is occurring in the Oaxaca coast region, or less time, if the seismic event hits near of this town. Also the SASO has been supported since its implementation for local commercial radio stations. Today the SAS and SASO have been generated respectively 13 and 3 Public Alert signals, also 63 and 5 Preventive Alerts ones. Nevertheless, the final effectiveness of the SASMEX Alert Signal services is sensible to the particular conditions of the user in risk, they must have their radio receiver or TV set turned on, also they must know what to do if the seismic warning is issued, other way they do not have opportunity to react reducing their vulnerability, mainly at night. These reason justify the support of the

  14. A mobile care system with alert mechanism.

    PubMed

    Lee, Ren-Guey; Chen, Kuei-Chien; Hsiao, Chun-Chieh; Tseng, Chwan-Lu

    2007-09-01

    Hypertension and arrhythmia are chronic diseases, which can be effectively prevented and controlled only if the physiological parameters of the patient are constantly monitored, along with the full support of the health education and professional medical care. In this paper, a role-based intelligent mobile care system with alert mechanism in chronic care environment is proposed and implemented. The roles in our system include patients, physicians, nurses, and healthcare providers. Each of the roles represents a person that uses a mobile device such as a mobile phone to communicate with the server setup in the care center such that he or she can go around without restrictions. For commercial mobile phones with Bluetooth communication capability attached to chronic patients, we have developed physiological signal recognition algorithms that were implemented and built-in in the mobile phone without affecting its original communication functions. It is thus possible to integrate several front-end mobile care devices with Bluetooth communication capability to extract patients' various physiological parameters [such as blood pressure, pulse, saturation of haemoglobin (SpO2), and electrocardiogram (ECG)], to monitor multiple physiological signals without space limit, and to upload important or abnormal physiological information to healthcare center for storage and analysis or transmit the information to physicians and healthcare providers for further processing. Thus, the physiological signal extraction devices only have to deal with signal extraction and wireless transmission. Since they do not have to do signal processing, their form factor can be further reduced to reach the goal of microminiaturization and power saving. An alert management mechanism has been included in back-end healthcare center to initiate various strategies for automatic emergency alerts after receiving emergency messages or after automatically recognizing emergency messages. Within the time

  15. Space Debris Alert System for Aviation

    NASA Astrophysics Data System (ADS)

    Sgobba, Tommaso

    2013-09-01

    Despite increasing efforts to accurately predict space debris re-entry, the exact time and location of re-entry is still very uncertain. Partially, this is due to a skipping effect uncontrolled spacecraft may experience as they enter the atmosphere at a shallow angle. Such effect difficult to model depends on atmospheric variations of density. When the bouncing off ends and atmospheric re-entry starts, the trajectory and the overall location of surviving fragments can be precisely predicted but the time to impact with ground, or to reach the airspace, becomes very short.Different is the case of a functional space system performing controlled re-entry. Suitable forecasts methods are available to clear air and maritime traffic from hazard areas (so-called traffic segregation).In US, following the Space Shuttle Columbia accident in 2003, a re-entry hazard areas location forecast system was putted in place for the specific case of major malfunction of a Reusable Launch Vehicles (RLV) at re-entry. The Shuttle Hazard Area to Aircraft Calculator (SHAAC) is a system based on ground equipment and software analyses and prediction tools, which require trained personnel and close coordination between the organization responsible for RLV operation (NASA for Shuttle) and the Federal Aviation Administration. The system very much relies on the operator's capability to determine that a major malfunction has occurred.This paper presents a US pending patent by the European Space Agency, which consists of a "smart fragment" using a GPS localizer together with pre- computed debris footprint area and direct broadcasting of such hazard areas.The risk for aviation from falling debris is very remote but catastrophic. Suspending flight over vast swath of airspace for every re-entering spacecraft or rocket upper stage, which is a weekly occurrence, would be extremely costly and disruptive.The Re-entry Direct Broadcasting Alert System (R- DBAS) is an original merging and evolution of the Re

  16. Alert!

    ERIC Educational Resources Information Center

    Villano, Matt

    2008-01-01

    Now more than ever, campus safety is of paramount importance. A reliable emergency mass notification system is one way to ensure the safety of constituents, and Brandeis University (MA) recently invested in a system that does the job. In this article, the author interviews John Turner, the school's director of networks and systems. Turner…

  17. Real Time Flood Alert System (RTFAS) for Puerto Rico

    USGS Publications Warehouse

    Lopez-Trujillo, Dianne

    2010-01-01

    The Real Time Flood Alert System is a web-based computer program, developed as a data integration tool, and designed to increase the ability of emergency managers to rapidly and accurately predict flooding conditions of streams in Puerto Rico. The system includes software and a relational database to determine the spatial and temporal distribution of rainfall, water levels in streams and reservoirs, and associated storms to determine hazardous and potential flood conditions. The computer program was developed as part of a cooperative agreement between the U.S. Geological Survey Caribbean Water Science Center and the Puerto Rico Emergency Management Agency, and integrates information collected and processed by these two agencies and the National Weather Service.

  18. Pilot Non-Conformance to Alerting System Commands

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1997-01-01

    Instances of pilot non-conformance to alerting system commands have been identified in previous studies. Pilot non-conformance changes the final behavior of the system, and therefore may reduce actual performance from that anticipated. A simulator study has examined pilot non-conformance, using the task of collision avoidance during closely spaced parallel approaches as a case study. Consonance between the display and the alerting system was found to significantly improve subject agreement with automatic alerts. Based on these results, a more general discussion of the factors involved in pilot conformance is given, and design guidelines for alerting systems are given.

  19. Tone-activated, remote, alert communication system

    NASA Technical Reports Server (NTRS)

    Baker, C. D.; Couvillon, L. A.; Hubbard, W. P.; Kollar, F. J.; Postal, R. B.; Tegnelia, C. R.

    1971-01-01

    Pocket sized transmitter, frequency modulated by crystal derived tones, with integral loop antenna provides police with easy operating alert signal communicator which uses patrol car radio to relay signal. Communication channels are time shared by several patrol units.

  20. Alert Messaging in the CMS Distributed Workflow System

    NASA Astrophysics Data System (ADS)

    Maxa, Zdenek

    2012-12-01

    WMAgent is the core component of the CMS workload management system. One of the features of this job managing platform is a configurable messaging system aimed at generating, distributing and processing alerts: short messages describing a given alert-worthy information or pathological condition. Apart from the framework's sub-components running within the WMAgent instances, there is a stand-alone application collecting alerts from all WMAgent instances running across the CMS distributed computing environment. The alert framework has a versatile design that allows for receiving alert messages also from other CMS production applications, such as PhEDEx data transfer manager. We present implementation details of the system, including its Python implementation using ZeroMQ, CouchDB message storage and future visions as well as operational experiences. Inter-operation with monitoring platforms such as Dashboard or Lemon is described.

  1. Alert Exchange Process Protocol

    NASA Technical Reports Server (NTRS)

    Groen, Frank

    2015-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.

  2. Real-time alerts and reminders using information systems.

    PubMed

    Wanderer, Jonathan P; Sandberg, Warren S; Ehrenfeld, Jesse M

    2011-09-01

    Adoption of information systems throughout the hospital environment has enabled the development of real-time physiologic alerts and clinician reminder systems. These clinical tools can be made available through the deployment of anesthesia information management systems (AIMS). Creating usable alert systems requires understanding of technical considerations. Various successful implementations are reviewed, encompassing cost reduction, improved revenue capture, timely antibiotic administration, and postoperative nausea and vomiting prophylaxis. Challenges to the widespread use of real-time alerts and reminders include AIMS adoption rates and the difficulty in choosing appropriate areas and approaches for information systems support.

  3. The Seismic Alert System of Mexico (SASMEX): Performance and Evolution

    NASA Astrophysics Data System (ADS)

    Espinosa Aranda, J.

    2013-05-01

    Originally the Seismic Alert System of Mexico (SASMEX) was proposed to integrate the Seismic Alert System of Mexico City (SAS), operating since 1991, with the Seismic Alert System of Oaxaca City (SASO), in services since 2003. And today, after the intense big earthquake activity observed in our world during 2010 and 2011, local governments of Mexico City, Oaxaca Estate, and the Mexican Ministry of the Interior have been promoting the expansion of this technological EEW development. Until 2012 SASMEX better coverage includes 48 new field seismic sensors (FS) deployed over the seismic region of Jalisco, Colima, Michoacan and Puebla, with someone enhancements over Guerrero and Oaxaca, to reach 97 FS. During 2013, 35 new FS has been proposed to SASMEX enhancements covering the Chiapas and Veracruz seismic regions. The SASMEX, with the support of the Mexico Valley Broadcasters Association (ARVM) since 1993, automatically issue Public and Preventive earthquake early warning signals in the Cities of Mexico, Toluca, Acapulco, Chilpancingo, and Oaxaca. The seismic warning range in each case is seated in accordance with local Civil Protection Authorities: Public Alert, if they expect strong earthquake effects, and Preventive Alert one, the effect could be moderated. Now the SASMEX warning time opportunity could be different to the 60 sec. average typically generated when SAS warned earthquake effects coming from Guerrero to Mexico City valley. Mexican EEW issued today reach: 16 Public and 62 Preventive Alert in Mexico City; 25 Public and 19 Preventive Alerts in Oaxaca City; also 14 Public and 4 Preventive Alerts in Acapulco; 14 Public and 5 Preventive Alerts in Chilpancingo. The earthquakes events registered by SASMEX FS until now reach 3448. With the support of private and Federal telecommunications infrastructure like, TELMEX, Federal Electric Commission, and the Mexican Security Ministry, it was developed a redundant communication system with pads to link the different

  4. The ANTARES telescope neutrino alert system

    NASA Astrophysics Data System (ADS)

    Ageron, M.; Aguilar, J. A.; Al Samarai, I.; Albert, A.; André, M.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Assis Jesus, A. C.; Astraatmadja, T.; Aubert, J.-J.; Baret, B.; Basa, S.; Bertin, V.; Biagi, S.; Bigi, A.; Bigongiari, C.; Bogazzi, C.; Bou-Cabo, M.; Bouhou, B.; Bouwhuis, M. C.; Brunner, J.; Busto, J.; Camarena, F.; Capone, A.; Cârloganu, C.; Carminati, G.; Carr, J.; Cecchini, S.; Charif, Z.; Charvis, Ph.; Chiarusi, T.; Circella, M.; Coniglione, R.; Costantini, H.; Coyle, P.; Curtil, C.; Decowski, M. P.; Dekeyser, I.; Deschamps, A.; Distefano, C.; Donzaud, C.; Dornic, D.; Dorosti, Q.; Drouhin, D.; Eberl, T.; Emanuele, U.; Enzenhöfer, A.; Ernenwein, J.-P.; Escoffier, S.; Fermani, P.; Ferri, M.; Flaminio, V.; Folger, F.; Fritsch, U.; Fuda, J.-L.; Galatà, S.; Gay, P.; Giacomelli, G.; Giordano, V.; Gómez-González, J. P.; Graf, K.; Guillard, G.; Halladjian, G.; Hallewell, G.; van Haren, H.; Hartman, J.; Heijboer, A. J.; Hello, Y.; Hernández-Rey, J. J.; Herold, B.; Hößl, J.; Hsu, C. C.; de Jong, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Katz, U.; Kavatsyuk, O.; Kooijman, P.; Kopper, C.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lamare, P.; Larosa, G.; Lattuada, D.; Lefèvre, D.; Lim, G.; Lo Presti, D.; Loehner, H.; Loucatos, S.; Mangano, S.; Marcelin, M.; Margiotta, A.; Martínez-Mora, J. A.; Meli, A.; Montaruli, T.; Moscoso, L.; Motz, H.; Neff, M.; Nezri, E.; Palioselitis, D.; Păvălaş, G. E.; Payet, K.; Payre, P.; Petrovic, J.; Piattelli, P.; Picot-Clemente, N.; Popa, V.; Pradier, T.; Presani, E.; Racca, C.; Reed, C.; Richardt, C.; Richter, R.; Rivière, C.; Robert, A.; Roensch, K.; Rostovtsev, A.; Ruiz-Rivas, J.; Rujoiu, M.; Russo, G. V.; Salesa, F.; Sapienza, P.; Schöck, F.; Schuller, J.-P.; Schüssler, F.; Shanidze, R.; Simeone, F.; Spies, A.; Spurio, M.; Steijger, J. J. M.; Stolarczyk, Th.; Sánchez-Losa, A.; Taiuti, M.; Tamburini, C.; Toscano, S.; Vallage, B.; van Elewyck, V.; Vannoni, G.; Vecchi, M.; Vernin, P.; Wijnker, G.; Wilms, J.; de Wolf, E.; Yepes, H.; Zaborov, D.; Zornoza, J. D.; Zúñiga, J.

    2012-03-01

    The ANTARES telescope has the capability to detect neutrinos produced in astrophysical transient sources. Potential sources include gamma-ray bursts, core collapse supernovae, and flaring active galactic nuclei. To enhance the sensitivity of ANTARES to such sources, a new detection method based on coincident observations of neutrinos and optical signals has been developed. A fast online muon track reconstruction is used to trigger a network of small automatic optical telescopes. Such alerts are generated for special events, such as two or more neutrinos, coincident in time and direction, or single neutrinos of very high energy.

  5. Pilot Non-Conformance to Alerting System Commands

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy

    1997-01-01

    This research project examined the effects of consonance between cockpit displays and alerting system as a technique to encourage pilots to conform to alerting system commands. An experiment used the task of collision avoidance during closely spaced parallel approaches as a case study, building upon previous experiments which identified instances of non-conformance and conflicts between the alerting criteria preferred by pilots, compared to that used by alerting systems. Using a workstation based, part-task simulator, each of 45 subjects completed 45 experiment runs. In each run, the subjects were told they were flying an approach. Their primary task was to keep their wings level despite turbulence through the use of a sidestick. The sidestick commands did not affect the path of the aircraft, however, so that consistent approach paths were be followed. Their secondary task was to indicate when an aircraft on a parallel approach is blundering towards them, as evidenced by the traffic display. Subjects were asked to press different buttons indicating whether they feel an avoidance maneuver is required by the traffic situation or not. At the completion of each run, subjects were asked to rate their confidence in their decision and, if appropriate, to rate the timeliness of automatic alerts when had been given. Three different automatic alert conditions were tested. The "No Automatic Alerts Given" condition is self-explanatory. In the "Automatic Alerts Based on NTZ Criteria" condition, an automatic alert was given when the NTZ criteria was triggered; this criteria is consistent with subject reactions in other studies, in which subjects were found to react, on average, when the other aircraft was 1350 min to the side of the own aircraft. In the "Automatic Alerts Based on MIT Criteria" condition, an automatic alert was given when the MIT criteria was triggered; this criteria was developed by Carpenter and Kuchar for parallel approaches to have better performance, at the

  6. Modeling Pilot State in Next Generation Aircraft Alert Systems

    NASA Technical Reports Server (NTRS)

    Carlin, Alan S.; Alexander, Amy L.; Schurr, Nathan

    2011-01-01

    The Next Generation Air Transportation System will introduce new, advanced sensor technologies into the cockpit that must convey a large number of potentially complex alerts. Our work focuses on the challenges associated with prioritizing aircraft sensor alerts in a quick and efficient manner, essentially determining when and how to alert the pilot This "alert decision" becomes very difficult in NextGen due to the following challenges: 1) the increasing number of potential hazards, 2) the uncertainty associated with the state of potential hazards as well as pilot slate , and 3) the limited time to make safely-critical decisions. In this paper, we focus on pilot state and present a model for anticipating duration and quality of pilot behavior, for use in a larger system which issues aircraft alerts. We estimate pilot workload, which we model as being dependent on factors including mental effort, task demands. and task performance. We perform a mathematically rigorous analysis of the model and resulting alerting plans. We simulate the model in software and present simulated results with respect to manipulation of the pilot measures.

  7. Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems

    NASA Technical Reports Server (NTRS)

    Song, Lixia; Kuchar, James K.

    2003-01-01

    Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air

  8. Developing, Implementing, and Assessing an Early Alert System

    ERIC Educational Resources Information Center

    Tampke, Dale R.

    2013-01-01

    Early alert systems offer institutions systematic approaches to identifying and intervening with students exhibiting at-risk behaviors. Many of these systems rely on a common format for student referral to central receiving point. Systems at larger institutions often use web-based technology to allow for a scalable (available campus wide) approach…

  9. Hanford Site Emergency Alerting System siren testing report

    SciTech Connect

    Weidner, L.B.

    1997-08-13

    The purpose of the test was to determine the effective coverage of the proposed upgrades to the existing Hanford Site Emergency Alerting System (HSEAS). The upgrades are to enhance the existing HSEAS along the Columbia River from the Vernita Bridge to the White Bluffs Boat Launch as well as install a new alerting system in the 400 Area on the Hanford Site. Five siren sites along the Columbia River and two sites in the 400 Area were tested to determine the site locations that will provide the desired coverage.

  10. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... all channels that carry programming to flash for the duration of the EAS emergency message. The audio... as interactive games.] Wireless Cable Systems (BRS/EBS Stations) Wireless cable systems are subject... to flash for the duration of the EAS emergency message. The audio alert must give the channel...

  11. The agile alert system for gamma-ray transients

    SciTech Connect

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Fioretti, V.; Chen, A. W.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Pellizzoni, A.; and others

    2014-01-20

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  12. The AGILE Alert System for Gamma-Ray Transients

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  13. Detection Algorithms of the Seismic Alert System of Mexico (SASMEX)

    NASA Astrophysics Data System (ADS)

    Cuellar Martinez, A.; Espinosa Aranda, J.; Ramos Perez, S.; Ibarrola Alvarez, G.; Zavala Guerrero, M.; Sasmex

    2013-05-01

    The importance of a rapid and reliable detection of an earthquake, allows taking advantage with more opportunity time of any possible opportunity warnings to the population. Thus detection algorithms in the sensing field station (FS) of an earthquake early earning system, must have a high rate of correct detection; this condition lets perform numerical processes to obtain appropriate parameters for the alert activation. During the evolution and continuous service of the Mexican Seismic Alert System (SASMEX) in more than 23 operation years, it has used various methodologies in the detection process to get the largest opportunity time when an earthquake occurs and it is alerted. In addition to the characteristics of the acceleration signal observed in sensing field stations, it is necessary the site conditions reducing urban noise, but sometimes it is not present through of the first operation years, however, urban growth near to FS cause urban noise, which should be tolerated while carrying out the relocation process of the station, and in the algorithm design should be contemplating the robustness to reduce possible errors and false detections. This work presents some results on detection algorithms used in Mexico for early warning systems for earthquakes considering recent events and different opportunity times obtained depending of the detections on P and S phases of the earthquake detected in the station. Some methodologies are reviewed and described in detail in this work and the main features implemented in The Seismic Alert System of Mexico City (SAS), in continuous operation since 1991, and the Seismic Alert System of Oaxaca City (SASO), today both comprise the SASMEX.

  14. DAIDALUS: Detect and Avoid Alerting Logic for Unmanned Systems

    NASA Technical Reports Server (NTRS)

    Munoz, Cesar; Narkawicz, Anthony; Hagen, George; Upchurch, Jason; Dutle, Aaron; Consiglio, Maria; Chamberlain, James

    2015-01-01

    This paper presents DAIDALUS (Detect and Avoid Alerting Logic for Unmanned Systems), a reference implementation of a detect and avoid concept intended to support the integration of Unmanned Aircraft Systems into civil airspace. DAIDALUS consists of self-separation and alerting algorithms that provide situational awareness to UAS remote pilots. These algorithms have been formally specified in a mathematical notation and verified for correctness in an interactive theorem prover. The software implementation has been verified against the formal models and validated against multiple stressing cases jointly developed by the US Air Force Research Laboratory, MIT Lincoln Laboratory, and NASA. The DAIDALUS reference implementation is currently under consideration for inclusion in the appendices to the Minimum Operational Performance Standards for Unmanned Aircraft Systems presently being developed by RTCA Special Committee 228.

  15. The NAS Alert System: a look at the first eight years

    USGS Publications Warehouse

    Fuller, Pam L.; Neilson, Matt; Huge, Dane H.

    2013-01-01

    The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.

  16. Emergency vehicle alert system, phase 2

    NASA Technical Reports Server (NTRS)

    Barr, Tom; Harper, Warren; Reed, Bill; Wallace, David

    1993-01-01

    The EVAS provides warning for hearing-impaired motor vehicle drivers that an emergency vehicle is in the local vicinity. Direction and distance to the emergency vehicle are presented visually to the driver. This is accomplished by a special RF transmission/reception system. During this phase the receiver and transmitter from Phase 1 were updated and modified and a directional antenna developed. The system was then field tested with good results. Static and dynamic (moving vehicle) tests were made with the direction determined correctly 98 percent of the time.

  17. 14 CFR 135.180 - Traffic Alert and Collision Avoidance System.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Traffic Alert and Collision Avoidance... Aircraft and Equipment § 135.180 Traffic Alert and Collision Avoidance System. (a) Unless otherwise... equipped with an approved traffic alert and collision avoidance system. If a TCAS II system is...

  18. 14 CFR 135.180 - Traffic Alert and Collision Avoidance System.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Traffic Alert and Collision Avoidance... Aircraft and Equipment § 135.180 Traffic Alert and Collision Avoidance System. (a) Unless otherwise... equipped with an approved traffic alert and collision avoidance system. If a TCAS II system is...

  19. 14 CFR 135.180 - Traffic Alert and Collision Avoidance System.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Traffic Alert and Collision Avoidance... Aircraft and Equipment § 135.180 Traffic Alert and Collision Avoidance System. (a) Unless otherwise... equipped with an approved traffic alert and collision avoidance system. If a TCAS II system is...

  20. 14 CFR 135.180 - Traffic Alert and Collision Avoidance System.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Traffic Alert and Collision Avoidance... Aircraft and Equipment § 135.180 Traffic Alert and Collision Avoidance System. (a) Unless otherwise... equipped with an approved traffic alert and collision avoidance system. If a TCAS II system is...

  1. 14 CFR 135.180 - Traffic Alert and Collision Avoidance System.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Traffic Alert and Collision Avoidance... Aircraft and Equipment § 135.180 Traffic Alert and Collision Avoidance System. (a) Unless otherwise... equipped with an approved traffic alert and collision avoidance system. If a TCAS II system is...

  2. IP telephony based danger alert communication system and its implementation

    NASA Astrophysics Data System (ADS)

    Rezac, Filip; Safarik, Jakub; Voznak, Miroslav; Tomala, Karel; Partila, Pavol

    2013-05-01

    This article discusses a danger alert system created as a part of the research project at Department of Telecommunications of Technical University of Ostrava. The aim of the system is to distribute pre-recorded voice messages in order to alert the called party in danger. This article describes individual technologies, which the application uses for its operation as well as issues relating to hardware requirements and transfer line bandwidth load. The article also describes new algorithms, which had to be developed in order to ensure the reliability of the system. Our intent is focused on disaster management, the message, which should be delivered within specified time span, is typed in the application and text-to-speech module ensures its transformation to a speech format, after that a particular scenario or warned area is selected and a target group is automatically unloaded. For this purpose, we have defined XML format for delivery of phone numbers which are located in the target area and these numbers are obtained from mobile BTS's (Base transmission stations). The benefit of such communication compared to others, is the fact, that it uses a phone call and, therefore, it is possible to get feedback who accepted the message and to improve efficiency of alert system. Finally, the list of unanswered calls is exported and these users can be informed via SMS.

  3. COMESEP: a new type of space weather alert system

    NASA Astrophysics Data System (ADS)

    Crosby, Norma; Veronig, Astrid; Robbrecht, Eva; Vrsnak, Bojan; Vennerstrom, Susanne; Malandraki, Olga; Dalla, Silvia; Srivastava, Nandita; Hesse, Michael; Odstrcil, Dusan

    2013-04-01

    Tools for forecasting geomagnetic storms and solar energetic particle (SEP) radiation storms are and have been developed under the three-year EU FP7 COMESEP (COronal Mass Ejections and Solar Energetic Particles) collaborative project. In its final year, the validation and implementation of the produced tools into an operational space weather alert system is now underway. Geomagnetic and SEP radiation storm alerts are being based on the COMESEP definition of risk. The COMESEP alert system will provide notifications for the space weather community. To achieve this the system relies on both models and data, the latter including near real-time data as well as historical data. One of the important outcomes of the scientific analysis has been to identify key ingredients that lead to magnetic storms and SEP events. COMESEP is a unique cross-collaboration effort and bridges the gap between the SEP, coronal mass ejection and terrestrial effects scientific communities. For more information see the project website (http://www.comesep.eu/). This work has received funding from the European Commission FP7 Project COMESEP (263252).

  4. Addressing Inpatient Glycaemic Control with an Inpatient Glucometry Alert System

    PubMed Central

    Seheult, J. N.; Pazderska, A.; Gaffney, P.; Fogarty, J.; Sherlock, M.; Gibney, J.; Boran, G.

    2015-01-01

    Background. Poor inpatient glycaemic control has a prevalence exceeding 30% and results in increased length of stay and higher rates of hospital complications and inpatient mortality. The aim of this study was to improve inpatient glycaemic control by developing an alert system to process point-of-care blood glucose (POC-BG) results. Methods. Microsoft Excel Macros were developed for the processing of daily glucometry data downloaded from the Cobas IT database. Alerts were generated according to ward location for any value less than 4 mmol/L (hypoglycaemia) or greater than 15 mmol/L (moderate-severe hyperglycaemia). The Diabetes Team provided a weekday consult service for patients flagged on the daily reports. This system was implemented for a 60-day period. Results. There was a statistically significant 20% reduction in the percentage of hyperglycaemic patient-day weighted values >15 mmol/L compared to the preimplementation period without a significant change in the percentage of hypoglycaemic values. The time-to-next-reading after a dysglycaemic POC-BG result was reduced by 14% and the time-to-normalization of a dysglycaemic result was reduced from 10.2 hours to 8.4 hours. Conclusion. The alert system reduced the percentage of hyperglycaemic patient-day weighted glucose values and the time-to-normalization of blood glucose. PMID:26290664

  5. Characterizing and Managing Intrusion Detection System (IDS) Alerts with Multi-Server/Multi-Priority Queuing Theory

    DTIC Science & Technology

    2014-12-26

    CHARACTERIZING AND MANAGING INTRUSION DETECTION SYSTEM (IDS) ALERTS WITH MULTI-SERVER/MULTI-PRIORITY...subject to copyright protection in the United States. AFIT-ENV-MS-14-D-24 CHARACTERIZING AND MANAGING INTRUSION DETECTION SYSTEM (IDS) ALERTS WITH...IDS) ALERTS WITH MULTI-SERVER/MULTI-PRIORITY QUEUING THEORY Christopher C. Olsen, BS Captain, USAF Approved

  6. Real-Time Mapping alert system; user's manual

    USGS Publications Warehouse

    Torres, L.A.

    1996-01-01

    The U.S. Geological Survey has an extensive hydrologic network that records and transmits precipitation, stage, discharge, and other water- related data on a real-time basis to an automated data processing system. Data values are recorded on electronic data collection platforms at field monitoring sites. These values are transmitted by means of orbiting satellites to receiving ground stations, and by way of telecommunication lines to a U.S. Geological Survey office where they are processed on a computer system. Data that exceed predefined thresholds are identified as alert values. These alert values can help keep water- resource specialists informed of current hydrologic conditions. The current alert status at monitoring sites is of critical importance during floods, hurricanes, and other extreme hydrologic events where quick analysis of the situation is needed. This manual provides instructions for using the Real-Time Mapping software, a series of computer programs developed by the U.S. Geological Survey for quick analysis of hydrologic conditions, and guides users through a basic interactive session. The software provides interactive graphics display and query of real-time information in a map-based, menu-driven environment.

  7. Developing an Early-Alert System to Promote Student Visits to Tutor Center

    ERIC Educational Resources Information Center

    Cai, Qijie; Lewis, Carrie L.; Higdon, Jude

    2015-01-01

    An early-alert system (MavCLASS) was developed and piloted in a large gateway math class with 611 freshman students to identify academically at-risk students and provide alert messages. It was found that there was significant association between the alert messages students received and their visits to the university's tutor center. Further, the…

  8. Helicopter acoustic alerting system for high-security facilities

    NASA Astrophysics Data System (ADS)

    Steadman, Robert L.; Hansen, Scott; Park, Chris; Power, Dennis

    2009-05-01

    Helicopters present a serious threat to high security facilities such as prisons, nuclear sites, armories, and VIP compounds. They have the ability to instantly bypass conventional security measures focused on ground threats such as fences, check-points, and intrusion sensors. Leveraging the strong acoustic signature inherent in all helicopters, this system would automatically detect, classify, and accurately track helicopters using multi-node acoustic sensor fusion. An alert would be generated once the threat entered a predefined 3-dimension security zone in time for security personnel to repel the assault. In addition the system can precisely identify the landing point on the facility grounds.

  9. Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy Ruth; Hansman, R. John; Corker, Kevin (Technical Monitor)

    1997-01-01

    Cockpit alerting systems monitor potentially hazardous situations, both inside and outside the aircraft. When a hazard is projected to occur, the alerting system displays alerts and/or command decisions to the pilot. However, pilots have been observed to not conform to alerting system commands by delaying their response or by not following the automatic commands exactly. This non-conformance to the automatic alerting system can reduce its benefit. Therefore, a need exists to understand the causes and effects of pilot non-conformance in order to develop automatic alerting systems whose commands the pilots are more likely to follow. These considerations were examined through flight simulator evaluations of the collision avoidance task during closely spaced parallel approaches. This task provided a useful case-study because the effects of non-conformance can be significant, given the time-critical nature of the task. A preliminary evaluation of alerting systems identified non-conformance in over 40% of the cases and a corresponding drop in collision avoidance performance. A follow-on experiment found subjects' alerting and maneuver selection criteria were consistent with different strategies than those used by automatic systems, indicating the pilot may potentially disagree with the alerting system if the pilot attempts to verify automatic alerts and commanded avoidance maneuvers. A final experiment found supporting automatic alerts with the explicit display of its underlying criteria resulted in more consistent subject reactions. In light of these experimental results, a general discussion of pilot non-conformance is provided. Contributing factors in pilot non-conformance include a lack of confidence in the automatic system and mismatches between the alerting system's commands and the pilots' own decisions based on the information available to them. The effects of non-conformance on system performance are discussed. Possible methods of reconciling mismatches are

  10. A simple heat alert system for Melbourne, Australia.

    PubMed

    Nicholls, Neville; Skinner, Carol; Loughnan, Margaret; Tapper, Nigel

    2008-05-01

    A simple heat alert system, based solely on predicted maximum and minimum daily temperatures, has been developed for the city of Melbourne in southeast Australia. The system is based upon a demonstration that, when mean daily temperature exceeds a threshold of 30 degrees C (mean of today's maximum temperature and tonight's minimum temperature), the average daily mortality of people aged 65 years or more is about 15-17% greater than usual. Similar numbers of excess deaths also occur when daily minimum temperatures exceed 24 degrees C (increases of 19-21% over expected death rate), so a heat alert system based solely on this widely available weather forecast variable is also feasible. No strong signal of excess heat-related deaths appears when the data are stratified using daily maximum temperatures. This may be because in Melbourne some days with very high maximum temperatures will be affected by the passage of cool changes and cold fronts in the afternoon, leading to a rapid drop in temperature (i.e., some days with high maximum temperatures will not continue to be hot throughout the day and into the evening). A single day with temperatures exceeding the thresholds noted above is sufficient to cause this increase in mortality, rather than requiring an extended heat wave. The increased daily mortality does not appear to represent a short-term advancement of mortality.

  11. Real-Time Mapping alert system; characteristics and capabilities

    USGS Publications Warehouse

    Torres, L.A.; Lambert, S.C.; Liebermann, T.D.

    1995-01-01

    The U.S. Geological Survey has an extensive hydrologic network that records and transmits precipitation, stage, discharge, and other water-related data on a real-time basis to an automated data processing system. Data values are recorded on electronic data collection platforms at field sampling sites. These values are transmitted by means of orbiting satellites to receiving ground stations, and by way of telecommunication lines to a U.S. Geological Survey office where they are processed on a computer system. Data that exceed predefined thresholds are identified as alert values. The current alert status at monitoring sites within a state or region is of critical importance during floods, hurricanes, and other extreme hydrologic events. This report describes the characteristics and capabilities of a series of computer programs for real-time mapping of hydrologic data. The software provides interactive graphics display and query of hydrologic information from the network in a real-time, map-based, menu-driven environment.

  12. Flood forecasting and alert system for Arda River basin

    NASA Astrophysics Data System (ADS)

    Artinyan, Eram; Vincendon, Beatrice; Kroumova, Kamelia; Nedkov, Nikolai; Tsarev, Petko; Balabanova, Snezhanka; Koshinchanov, Georgy

    2016-10-01

    The paper presents the set-up and functioning of a flood alert system based on SURFEX-TOPODYN platform for the cross-border Arda River basin. The system was built within a Bulgarian-Greek project funded by the European Territorial Cooperation (ETC) Programme and is in operational use since April 2014. The basin is strongly influenced by Mediterranean cyclones during the autumn-winter period and experiences dangerous rapid floods, mainly after intensive rain, often combined with snow melt events. The steep mountainous terrain leads to floods with short concentration time and high river speed causing damage to settlements and infrastructure. The main challenge was to correctly simulate the riverflow in near-real time and to timely forecast peak floods for small drainage basins below 100 km2 but also for larger ones of about 1900 km2 using the same technology. To better account for that variability, a modification of the original hydrological model parameterisation is proposed. Here we present the first results of a new model variant which uses dynamically adjusted TOPODYN river velocity as function of the computed partial streamflow discharge. Based on historical flooding data, river sections along endangered settlements were included in the river flow forecasting. A continuous hydrological forecast for 5 days ahead was developed for 18 settlements in Bulgaria and for the border with Greece, thus giving enough reaction time in case of high floods. The paper discusses the practical implementation of models for the Arda basin, the method used to calibrate the models' parameters, the results of the calibration-validation procedure and the way the information system is organised. A real case of forecasted rapid floods that occurred after the system's finalisation is analysed. One of the important achievements of the project is the on-line presentation of the forecasts that takes into account their temporal variability and uncertainty. The web presentation includes a

  13. Lane change behavior with a side blind zone alert system.

    PubMed

    Kiefer, Raymond J; Hankey, Jonathan M

    2008-03-01

    This in-traffic study explored the effect of a side blind zone alert (SBZA) system on driver lane change behavior. Such a system may help drivers avoid lane change crashes by warning them with a side mirror display when a vehicle is detected in their blind zone. Participants drove with and without the SBZA system enabled, and were instructed to evaluate vehicle ride characteristics and only given an "incidental" system explanation. Overall, drivers failed to execute "over the shoulder" (blind zone) glances for 68 and 85% of the left and right lane changes, respectively. This suggests that the SBZA display provides information to the driver that often fails to be obtained via over the shoulder glances. In addition, when the SBZA system was enabled there was a 31% reduction in left lane changes attempted without the driver checking the left mirror, and a 23% reduction in right lane changes attempted without the driver checking the inside mirror. These results, coupled with the assumption that "did not see other vehicle" is a principal causal factor in many lane change crashes, suggests that the SBZA system may assist drivers in avoiding lane change crashes.

  14. Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor

    2016-01-01

    A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method

  15. Feasibility study of a caregiver seizure alert system in canine epilepsy.

    PubMed

    Coles, Lisa D; Patterson, Edward E; Sheffield, W Douglas; Mavoori, Jaideep; Higgins, Jason; Michael, Bland; Leyde, Kent; Cloyd, James C; Litt, Brian; Vite, Charles; Worrell, Gregory A

    2013-10-01

    A device capable of detecting seizures and alerting caregivers would be a major advance for epilepsy management, and could be used to guide early intervention and prevent seizure-related injuries. The objective of this work was to evaluate a seizure advisory system (SAS) that alerts caregivers of seizures in canines with naturally occurring epilepsy. Four dogs with epilepsy were implanted with a SAS that wirelessly transmits continuous intracranial EEG (iEEG) to an external device embedded with a seizure detection algorithm and the capability to alert caregivers. In this study a veterinarian was alerted by automated text message if prolonged or repetitive seizures occurred, and a rescue therapy protocol was implemented. The performance of the SAS caregiver alert was evaluated over the course of 8 weeks. Following discontinuation of antiepileptic drugs, the dogs experienced spontaneous unprovoked partial seizures that secondarily generalized. Three prolonged or repetitive seizure episodes occurred in 2 of the dogs. On each occasion, the SAS caregiver alert successfully alerted an on call veterinarian who confirmed the seizure activity via remote video-monitoring. A rescue medication was then administered and the seizures were aborted. This study demonstrates the feasibility of a SAS to alert caregivers to the occurrence of prolonged or repetitive seizures and enables rescue medications to be delivered in a timely manner. The SAS may improve the management of human epilepsy by alerting caregivers of seizures, enabling early interventions, and potentially improving outcomes and quality of life of patients and caregivers.

  16. 14 CFR 91.221 - Traffic alert and collision avoidance system equipment and use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Traffic alert and collision avoidance... RULES Equipment, Instrument, and Certificate Requirements § 91.221 Traffic alert and collision avoidance... collision avoidance system installed in a U.S.-registered civil aircraft must be approved by...

  17. 14 CFR 91.221 - Traffic alert and collision avoidance system equipment and use.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Traffic alert and collision avoidance... RULES Equipment, Instrument, and Certificate Requirements § 91.221 Traffic alert and collision avoidance... collision avoidance system installed in a U.S.-registered civil aircraft must be approved by...

  18. 14 CFR 91.221 - Traffic alert and collision avoidance system equipment and use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Traffic alert and collision avoidance... RULES Equipment, Instrument, and Certificate Requirements § 91.221 Traffic alert and collision avoidance... collision avoidance system installed in a U.S.-registered civil aircraft must be approved by...

  19. 14 CFR 91.221 - Traffic alert and collision avoidance system equipment and use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Traffic alert and collision avoidance... RULES Equipment, Instrument, and Certificate Requirements § 91.221 Traffic alert and collision avoidance... collision avoidance system installed in a U.S.-registered civil aircraft must be approved by...

  20. 14 CFR 91.221 - Traffic alert and collision avoidance system equipment and use.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Traffic alert and collision avoidance... RULES Equipment, Instrument, and Certificate Requirements § 91.221 Traffic alert and collision avoidance... collision avoidance system installed in a U.S.-registered civil aircraft must be approved by...

  1. 75 FR 26269 - Draft Programmatic Environmental Assessment for the Integrated Public Alert and Warning Program's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... Public Alert and Warning Program's Construction Projects AGENCY: Federal Emergency Management Agency, DHS... Public Alert and Warning Program (IPAWS). The construction actions will be taken to ensure that FEMA meets its responsibilities under Executive Order 13407, Public Alert and Warning System, by...

  2. A Model for the Effectiveness of Aircraft Alerting and Warning Systems

    NASA Technical Reports Server (NTRS)

    Curry, R. E.; Neu, J. E.

    1984-01-01

    The effectiveness of an alerting system with a single alert was analyzed. The pilot's decision behavior is modeled by the theory of signal detection and therefore accounts for different strengths of cross check information and different pilot criteria. The model includes the effects of the alerting and warning system (CAWS) error rate; the pilot's past experience with the CAWS accuracy; his reliance on the CAWS rather than independent monitoring; missed alerts; and adoption of a minimum error or Neyman-Pearson objective rather than minimum cost objective. It is showwn that for rare events: (1) the expected cost is greatly increased if the pilot ignores the a posteriori information in the existence of an alert; (2) the expected cost is insensitive to CAWS Type 1 errors; and (3) the expected cost is sensitive to CAWS type 2 errors only when the cross check information is ambiguous.

  3. Real-time Seismic Alert System of NIED

    NASA Astrophysics Data System (ADS)

    Horiuchi, S.; Fujinawa, Y.; Negishi, H.; Matsumoto, T.; Fujiwara, H.; Kunugi, T.; Hayashi, Y.

    2001-12-01

    An extensive seismic network has been constructed nationwide composed of hi-sensitivity seismographic network, broadband seismographic network and strong motion seismographic network. All these data from some 3,000 sites belonging to NIED, JMA and universities are to be accumulated and distributed through NIED to any scientists and engineering through INTERNET under the coordination of the National Seismic Research Committee of MEXT. As a practical application of those data we are now developing a real-time seismic alert information system for the purpose of providing short-term warning of imminent strong grounds motions from major earthquakes from several seconds to a few days. The contents of information are seismic focal parameters (several seconds), seismic fault plane solutions (some 10 seconds), after-shock activities (several minutes-a few days ). The fundamental fault parameters are used to build specific information at sites for particular users for use of triggering automated and /or half-automated responses. The most important application is an immediate estimate of expected shaking distribution and damages in a district using synthetic database and site effects for local governments to initial proper measures of hazard mitigation. Another application is estimation of arrival time and shaking strength at any individual site for human lives to be safeguarded. The system could also start an automatic electrical isolation and protection of computer systems, protection of hazardous chronic systems, transportation systems and so on. The information are corrected successively as seismic ground motion are received at a larger number of sites in time with the result that more accurate and more sophisticated earthquake information is transmitted to any user. Besides the rapid determination of seismic parameters, one of essential items in this alert system is the data transmission means. The data transmission is chosen to assure negligibly small delay of data

  4. Optimizing the response to surveillance alerts in automated surveillance systems.

    PubMed

    Izadi, Masoumeh; Buckeridge, David L

    2011-02-28

    Although much research effort has been directed toward refining algorithms for disease outbreak alerting, considerably less attention has been given to the response to alerts generated from statistical detection algorithms. Given the inherent inaccuracy in alerting, it is imperative to develop methods that help public health personnel identify optimal policies in response to alerts. This study evaluates the application of dynamic decision making models to the problem of responding to outbreak detection methods, using anthrax surveillance as an example. Adaptive optimization through approximate dynamic programming is used to generate a policy for decision making following outbreak detection. We investigate the degree to which the model can tolerate noise theoretically, in order to keep near optimal behavior. We also evaluate the policy from our model empirically and compare it with current approaches in routine public health practice for investigating alerts. Timeliness of outbreak confirmation and total costs associated with the decisions made are used as performance measures. Using our approach, on average, 80 per cent of outbreaks were confirmed prior to the fifth day of post-attack with considerably less cost compared to response strategies currently in use. Experimental results are also provided to illustrate the robustness of the adaptive optimization approach and to show the realization of the derived error bounds in practice.

  5. Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System

    PubMed Central

    Beccaro, M. A. Del; Villanueva, R.; Knudson, K. M.; Harvey, E. M.; Langle, J. M.; Paul, W.

    2010-01-01

    Objective We sought to determine the frequency and type of decision support alerts by location and ordering provider role during Computerized Provider Order Entry (CPOE) medication ordering. Using these data we adjusted the decision support tools to reduce the number of alerts. Design Retrospective analyses were performed of dose range checks (DRC), drug-drug interaction and drug-allergy alerts from our electronic medical record. During seven sampling periods (each two weeks long) between April 2006 and October 2008 all alerts in these categories were analyzed. Another audit was performed of all DRC alerts by ordering provider role from November 2008 through January 2009. Medication ordering error counts were obtained from a voluntary error reporting system. Measurement/Results Between April 2006 and October 2008 the percent of medication orders that triggered a dose range alert decreased from 23.9% to 7.4%. The relative risk (RR) for getting an alert was higher at the start of the interventions versus later (RR= 2.40, 95% CI 2.28-2.52; p< 0.0001). The percentage of medication orders that triggered alerts for drug-drug interactions also decreased from 13.5% to 4.8%. The RR for getting a drug interaction alert at the start was 1.63, 95% CI 1.60-1.66; p< 0.0001. Alerts decreased in all clinical areas without an increase in reported medication errors. Conclusion We reduced the quantity of decision support alerts in CPOE using a systematic approach without an increase in reported medication errors PMID:23616845

  6. Development of an Alert System to Detect Drug Interactions with Herbal Supplements using Medical Record Data

    PubMed Central

    Archer, Melissa; Proulx, Joshua; Shane-McWhorter, Laura; Bray, Bruce E.; Zeng-Treitler, Qing

    2014-01-01

    While potential medication-to-medication interaction alerting engines exist in many clinical applications, few systems exist to automatically alert on potential medication to herbal supplement interactions. We have developed a preliminary knowledge base and rules alerting engine that detects 259 potential interactions between 9 supplements, 62 cardiac medications, and 19 drug classes. The rules engine takes into consideration 12 patient risk factors and 30 interaction warning signs to help determine which of three different alert levels to categorize each potential interaction. A formative evaluation was conducted with two clinicians to set initial thresholds for each alert level. Additional work is planned add more supplement interactions, risk factors, and warning signs as well as to continue to set and adjust the inputs and thresholds for each potential interaction. PMID:25954326

  7. Some human factors issues in the development and evaluation of cockpit alerting and warning systems

    NASA Technical Reports Server (NTRS)

    Randle, R. J., Jr.; Larsen, W. E.; Williams, D. H.

    1980-01-01

    A set of general guidelines for evaluating a newly developed cockpit alerting and warning system in terms of human factors issues are provided. Although the discussion centers around a general methodology, it is made specifically to the issues involved in alerting systems. An overall statement of the current operational problem is presented. Human factors problems with reference to existing alerting and warning systems are described. The methodology for proceeding through system development to system test is discussed. The differences between traditional human factors laboratory evaluations and those required for evaluation of complex man-machine systems under development are emphasized. Performance evaluation in the alerting and warning subsystem using a hypothetical sample system is explained.

  8. Alcohol Alert

    MedlinePlus

    ... Us You are here Home » Alcohol Alert Alcohol Alert The NIAAA Alcohol Alert is a quarterly bulletin that disseminates important research ... text. To order single copies of select Alcohol Alerts, see ordering Information . To view publications in PDF ...

  9. EU alerting and reporting systems for potential chemical public health threats and hazards.

    PubMed

    Orford, R; Crabbe, H; Hague, C; Schaper, A; Duarte-Davidson, R

    2014-11-01

    A number of European and international IT platforms are used to notify competent authorities of new potential chemical exposures. Recently the European Parliament and the Council of European Union adopted new legislation that aims to improve the co-ordinated response to cross border health threats (Decision 1082/2013/EU). The Decision, inter alia, sets provisions on notification, ad hoc monitoring and coordination of public health measures following serious cross border threats to health from biological, chemical and environmental events as well as events that have an unknown origin. The legal instrument applies to all European Union Member States and is comparable to the International Health Regulations in its content, requirements and adoption of a multiple hazards approach. An inter-sectoral and multidisciplinary response to events with potentially dangerous cross border exposure pathways is often required. For example, European Poisons Centres may be aware of cases of toxic exposure to a product and, in parallel, trading standards may be aware of the same product due to a breach of consumer product standards. Whilst both cases would have been recorded for separate purposes in different alerting systems, they relate to the same exposure pathway; therefore a process for linking these records would allow a more robust approach to risk assessment and risk mitigation. The Decision seeks to reconcile this issue for serious threats by linking relevant platforms into one overarching higher level risk management IT platform called the Early Warning Response System (EWRS). This system will serve to link other sectors within the European Commission (EC) to public health (e.g. medicines), as well as other EU agencies and international bodies via co-notification features. Other European alert systems will be linked to EWRS to facilitate information sharing at both the assessment and management levels. This paper provides a timely overview of the main systems run by the EC

  10. System and Method for Providing Model-Based Alerting of Spatial Disorientation to a Pilot

    NASA Technical Reports Server (NTRS)

    Conner, Kevin J (Inventor); Mathan, Santosh (Inventor); Johnson, Steve (Inventor)

    2015-01-01

    A system and method monitor aircraft state parameters, for example, aircraft movement and flight parameters, applies those inputs to a spatial disorientation model, and makes a prediction of when pilot may become spatially disoriented. Once the system predicts a potentially disoriented pilot, the sensitivity for alerting the pilot to conditions exceeding a threshold can be increased and allow for an earlier alert to mitigate the possibility of an incorrect control input.

  11. ECG Holter monitor with alert system and mobile application

    NASA Astrophysics Data System (ADS)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  12. Improving patient safety by modifying provider ordering behavior using alerts (CDSS) in CPOE system.

    PubMed

    Saxena, Kshitij; Lung, Barry R; Becker, Jody R

    2011-01-01

    Medication errors are not unusual in acute care settings. This prospective time series analysis/study evaluates the use of Clinical Decision Support System (CDSS)/alerts in helping providers not to make errors, when putting in orders in a CPOE system. We reviewed electronic health records for all the inpatients coming to 5 community hospitals for a 6 months duration (July 2010 - December 2010). Responses to 9 synchronous alerts (CDSS tools) were studied, that were prompted on computer screens when providers were putting in medication orders in EMR. These alerts guided the providers regarding any drug duplications, interactions, contraindications of the prescribed medicine with patient's clinical condition etc. The CDSS system in place changed the physician behavior & patient therapy 41.75% of the times when medication orders were placed. These alerts substantially decreased the medication error rate/adverse drug events (ADE's) in the patients receiving care at these 5 hospitals.

  13. Traffic Alert and Collision Avoidance System - Operational Simulation.

    DTIC Science & Technology

    1985-03-01

    must be understood that the parameter settings used (in the TCAS logic] depend upon a prompt and positive response on the part of the pilot".(3) Since...4.2.1-3) was located in the weather radar position (on the forward panel of the center aisle stand). A separately installed speaker presented the alert...during both the training and test flight, and the reasons for these procedures, every flight crew was observed to make intentional, positive and

  14. Real Time Alert System: A Disease Management System Leveraging Health Information Exchange

    PubMed Central

    Anand, Vibha; Sheley, Meena E.; Xu, Shawn; Downs, Stephen M.

    2012-01-01

    Background Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Methods: Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA’s performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Results: Our results show that RTA was successfully able to deliver “just in time” patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. Conclusions: We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient’s asthma related emergency room admission so further follow up can happen in near real time. PMID:23569648

  15. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System

    PubMed Central

    Ammenwerth, E.; Roehrer, E.; Pelayo, S.; Vasseur, F.; Beuscart-Zéphir, M.-C.

    2015-01-01

    Summary Objectives Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. Methods A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Results Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Conclusion Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology. PMID:26123906

  16. MyEEW: A Smartphone App for the ShakeAlert System

    NASA Astrophysics Data System (ADS)

    Strauss, J. A.; Allen, S.; Allen, R. M.; Hellweg, M.

    2015-12-01

    Earthquake Early Warning (EEW) is a system that can provide a few to tens of seconds warning prior to ground shaking at a user's location. The goal and purpose of such a system is to reduce, or minimize, the damage, costs, and casualties resulting from an earthquake. A demonstration earthquake early warning system (ShakeAlert) is undergoing testing in the United States by the UC Berkeley Seismological Laboratory, Caltech, ETH Zurich, University of Washington, the USGS, and beta users in California and the Pacific Northwest. The UC Berkeley Seismological Laboratory has created a smartphone app called MyEEW, which interfaces with the ShakeAlert system to deliver early warnings to individual users. Many critical facilities (transportation, police, and fire) have control rooms, which could run a centralized interface, but our ShakeAlert Beta Testers have also expressed their need for mobile options. This app augments the basic ShakeAlert Java desktop applet by allowing workers off-site (or merely out of hearing range) to be informed of coming hazards. MyEEW receives information from the ShakeAlert system to provide users with real-time information about shaking that is about to happen at their individual location. It includes a map, timer, and earthquake information similar to the Java desktop User Display. The app will also feature educational material to help users craft their own response and resiliency strategies. The app will be open to UC Berkeley Earthquake Research Affiliates members for testing in the near future.

  17. Impact-based earthquake alerts with the U.S. Geological Survey's PAGER system: what's next?

    USGS Publications Warehouse

    Wald, D.J.; Jaiswal, K.S.; Marano, K.D.; Garcia, D.; So, E.; Hearne, M.

    2012-01-01

    In September 2010, the USGS began publicly releasing earthquake alerts for significant earthquakes around the globe based on estimates of potential casualties and economic losses with its Prompt Assessment of Global Earthquakes for Response (PAGER) system. These estimates significantly enhanced the utility of the USGS PAGER system which had been, since 2006, providing estimated population exposures to specific shaking intensities. Quantifying earthquake impacts and communicating estimated losses (and their uncertainties) to the public, the media, humanitarian, and response communities required a new protocol—necessitating the development of an Earthquake Impact Scale—described herein and now deployed with the PAGER system. After two years of PAGER-based impact alerting, we now review operations, hazard calculations, loss models, alerting protocols, and our success rate for recent (2010-2011) events. This review prompts analyses of the strengths, limitations, opportunities, and pressures, allowing clearer definition of future research and development priorities for the PAGER system.

  18. A Retrospective Study on Patient Characteristics and Telehealth Alerts Indicative of Key Medical Events for Heart Failure Patients at a Home Health Agency

    PubMed Central

    Bowles, Kathryn; Hanlon, Alexandra; Topaz, Maxim; Chittams, Jesse

    2013-01-01

    Abstract Objective: To explore association of patient characteristics and telehealth alert data with all-cause key medical events (KMEs) of emergency department (ED) visits and hospitalizations as well as cardiac-related KMEs of ED visits, hospitalizations, and medication changes. Materials and Methods: A 6-month retrospective study was conducted of electronic patient records of heart failure (HF) patients using telehealth services at a Massachusetts home health agency. Data collected included patient demographic, psychosocial, disease severity factors and telehealth vital signs alerts. Association between patient characteristics and KMEs was analyzed by Generalized Estimating Equations. Results: The sample comprised 168 patients with a mean age of 83 years, 56% females, and 96% white. Ninety-nine cardiac-related KMEs and 87 all-cause KMEs were recorded for the subjects. Odds of a cardiac-related KME increased by 161% with the presence of valvular co-morbidity (p=0.001) and 106% with increased number of telehealth alerts (adjusted p<0.0001). Odds of an all-cause KME increased by 124% (p=0.02), 127% (p=0.01), and 70% (adjusted p<0.0001) with the presence of cancer co-morbidity, anxiety, and increased number of telehealth alerts, respectively. Overall, only 3% of all telehealth alerts were associated with KMEs. Conclusions: The very low proportion of telehealth vital sign alerts associated with KMEs indicates that telehealth alerts alone cannot inform the need for intervention within the larger context of HF care delivery in the homecare setting. Patient-relevant data such as psychosocial and symptom status, involvement with HF self-management, and presence of co-morbidities could further inform the need for interventions for HF patients in the homecare setting. PMID:23808888

  19. SAPIR collision alert system as part of IR MWS suite for helicopter fleets

    NASA Astrophysics Data System (ADS)

    Nadav, Shavit; Varsano, Louisa; Oz, Saar; Schlisselberg, Raanan

    2009-05-01

    SAPIR system provides a suite of IR based situation awareness functions offered as add on system for ELISRA PAWS family of missile warning solutions. A major operational need for airborne platforms flying in formation is automatic collision alert capability. By using covert IR-MWS technology SAPIR passively tracks and monitors wingman position thereby enabling aircrew to focus on mission goals without compromising their safety. The paper presents results of operational problem study, system design and field testing demonstration of performance for SAPIR collision alert function targeting helicopter fleets.

  20. Wearable real-time ecg monitoring with emergency alert system for scuba diving.

    PubMed

    Cibis, Tobias; Groh, Benjamin H; Gatermann, Heike; Leutheuser, Heike; Eskofier, Bjoern M

    2015-01-01

    Medical diagnosis is the first level for recognition and treatment of diseases. To realize fast diagnosis, we propose a concept of a basic framework for the underwater monitoring of a diver's ECG signal, including an alert system that warns the diver of predefined medical emergency situations. The framework contains QRS detection, heart rate calculation and an alert system. After performing a predefined study protocol, the algorithm's accuracy was evaluated with 10 subjects in a dry environment and with 5 subjects in an underwater environment. The results showed that, in 3 out of 5 dives as well as in dry environment, data transmission remained stable. In these cases, the subjects were able to trigger the alert system. The evaluated data showed a clear ECG signal with a QRS detection accuracy of 90 %. Thus, the proposed framework has the potential to detect and to warn of health risks. Further developments of this sample concept can imply an extension for monitoring different biomedical parameters.

  1. Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1997-01-01

    Pilot non-conformance to alerting system commands has been noted in general and to a TCAS-like collision avoidance system in a previous experiment. This paper details two experiments studying collision avoidance during closely-spaced parallel approaches in instrument meteorological conditions (IMC), and specifically examining possible causal factors of, and design solutions to, pilot non-conformance.

  2. Alerts Analysis and Visualization in Network-based Intrusion Detection Systems

    SciTech Connect

    Yang, Dr. Li

    2010-08-01

    The alerts produced by network-based intrusion detection systems, e.g. Snort, can be difficult for network administrators to efficiently review and respond to due to the enormous number of alerts generated in a short time frame. This work describes how the visualization of raw IDS alert data assists network administrators in understanding the current state of a network and quickens the process of reviewing and responding to intrusion attempts. The project presented in this work consists of three primary components. The first component provides a visual mapping of the network topology that allows the end-user to easily browse clustered alerts. The second component is based on the flocking behavior of birds such that birds tend to follow other birds with similar behaviors. This component allows the end-user to see the clustering process and provides an efficient means for reviewing alert data. The third component discovers and visualizes patterns of multistage attacks by profiling the attacker s behaviors.

  3. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City.

    PubMed

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-07-29

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers' and cyclists' Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper.

  4. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City

    PubMed Central

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-01-01

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers’ and cyclists’ Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper. PMID:26230695

  5. Modeling Pilot Behavior for Assessing Integrated Alert and Notification Systems on Flight Decks

    NASA Technical Reports Server (NTRS)

    Cover, Mathew; Schnell, Thomas

    2010-01-01

    Numerous new flight deck configurations for caution, warning, and alerts can be conceived; yet testing them with human-in-the-Ioop experiments to evaluate each one would not be practical. New sensors, instruments, and displays are being put into cockpits every day and this is particularly true as we enter the dawn of the Next Generation Air Transportation System (NextGen). By modeling pilot behavior in a computer simulation, an unlimited number of unique caution, warning, and alert configurations can be evaluated 24/7 by a computer. These computer simulations can then identify the most promising candidate formats to further evaluate in higher fidelity, but more costly, Human-in-the-Ioop (HITL) simulations. Evaluations using batch simulations with human performance models saves time, money, and enables a broader consideration of possible caution, warning, and alerting configurations for future flight decks.

  6. An MFC-based online monitoring and alert system for activated sludge process.

    PubMed

    Xu, Gui-Hua; Wang, Yun-Kun; Sheng, Guo-Ping; Mu, Yang; Yu, Han-Qing

    2014-10-27

    In this study, based on a simple, compact and submersible microbial fuel cell (MFC), a novel online monitoring and alert system with self-diagnosis function was established for the activated sludge (AS) process. Such a submersible MFC utilized organic substrates and oxygen in the AS reactor as the electron donor and acceptor respectively, and could provide an evaluation on the status of the AS reactor and thus give a reliable early warning of potential risks. In order to evaluate the reliability and sensitivity of this online monitoring and alert system, a series of tests were conducted to examine the response of this system to various shocks imposed on the AS reactor. The results indicate that this online monitoring and alert system was highly sensitive to the performance variations of the AS reactor. The stability, sensitivity and repeatability of this online system provide feasibility of being incorporated into current control systems of wastewater treatment plants to real-time monitor, diagnose, alert and control the AS process.

  7. Feature-based alert correlation in security systems using self organizing maps

    NASA Astrophysics Data System (ADS)

    Kumar, Munesh; Siddique, Shoaib; Noor, Humera

    2009-04-01

    The security of the networks has been an important concern for any organization. This is especially important for the defense sector as to get unauthorized access to the sensitive information of an organization has been the prime desire for cyber criminals. Many network security techniques like Firewall, VPN Concentrator etc. are deployed at the perimeter of network to deal with attack(s) that occur(s) from exterior of network. But any vulnerability that causes to penetrate the network's perimeter of defense, can exploit the entire network. To deal with such vulnerabilities a system has been evolved with the purpose of generating an alert for any malicious activity triggered against the network and its resources, termed as Intrusion Detection System (IDS). The traditional IDS have still some deficiencies like generating large number of alerts, containing both true and false one etc. By automatically classifying (correlating) various alerts, the high-level analysis of the security status of network can be identified and the job of network security administrator becomes much easier. In this paper we propose to utilize Self Organizing Maps (SOM); an Artificial Neural Network for correlating large amount of logged intrusion alerts based on generic features such as Source/Destination IP Addresses, Port No, Signature ID etc. The different ways in which alerts can be correlated by Artificial Intelligence techniques are also discussed. . We've shown that the strategy described in the paper improves the efficiency of IDS by better correlating the alerts, leading to reduced false positives and increased competence of network administrator.

  8. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Ground proximity warning-glide slope... Equipment Requirements § 121.360 Ground proximity warning-glide slope deviation alerting system. (a) No... turbine-powered airplane unless it is equipped with a ground proximity warning/glide slope...

  9. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Ground proximity warning-glide slope... Equipment Requirements § 121.360 Ground proximity warning-glide slope deviation alerting system. (a) No... turbine-powered airplane unless it is equipped with a ground proximity warning/glide slope...

  10. 21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL...

  11. 21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL...

  12. 21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL...

  13. 21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL...

  14. Three-dimensional audio versus head-down traffic alert and collision avoidance system displays.

    PubMed

    Begault, D R; Pittman, M T

    1996-01-01

    The advantage of a head-up auditory display for situational awareness was evaluated in an experiment designed to measure and compare the acquisition time for capturing visual targets under two conditions: standard head-down Traffic Alert and Collision Avoidance System display and three-dimensional (3-D) audio Traffic Alert and Collision Avoidance System presentation. (The technology used for 3-D audio presentation allows a stereo headphone user to potentially localize a sound at any externalized position in 3-D auditory space). Ten commercial airline crews were tested under full-mission simulation conditions at the NASA-Ames Crew-Vehicle Systems Research Facility Advanced Concepts Flight Simulator. Scenario software generated targets corresponding to aircraft that activated a 3-D aural advisory (the head-up auditory condition) or a standard, visual-audio TCAS advisory (map display with monaural audio alert). Results showed a significant difference in target acquisition time between the two conditions, favoring the 3-D audio Traffic Alert and Collision Avoidance System condition by 500 ms.

  15. Development of the Runway Incursion Advisory and Alerting System (RIAAS): Research Summary

    NASA Technical Reports Server (NTRS)

    Jones, Denise R. (Technical Monitor); Cassell, Rick

    2005-01-01

    This report summarizes research conducted on an aircraft based Runway Incursion Advisory and Alerting System (RIAAS) developed under a cooperative agreement between Rannoch Corporation and the NASA Langley Research Center. A summary of RIAAS is presented along with results from simulation and flight testing, safety benefits, and key technical issues.

  16. 21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL...

  17. Radar-based alert system to operate a sewerage network: relevance and operational effectiveness after several years of use.

    PubMed

    Faure, D; Payrastre, O; Auchet, P

    2005-01-01

    Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.

  18. TALON - The Telescope Alert Operation Network System : intelligent linking of distributed autonomous robotic telescopes

    SciTech Connect

    White, R. R.; Wren, J.; Davis, H. R.; Galassi, M. C.; Starr, D. L.; Vestrand, W. T.; Wozniak, P. R.

    2004-01-01

    The internet has brought about great change in the astronomical community, but this interconnectivity is just starting to be exploited for use in instrumentation. Utilizing the internet for communicating between distributed astronomical systems is still in its infancy, but it already shows great potential. Here we present an example of a distributed network of telescopes that performs more efficienfiy in synchronous operation than as individual instruments. RAPid Telescopes for Optical Response (RAPTOR) is a system of telescopes at LANL that has intelligent intercommunication, combined with wide-field optics, temporal monitoring software, and deep-field follow-up capability all working in closed-loop real-time operation. The Telescope ALert Operations Network (TALON) is a network server that allows intercommunication of alert triggers from external and internal resources and controls the distribution of these to each of the telescopes on the network. TALON is designed to grow, allowing any number of telescopes to be linked together and communicate. Coupled with an intelligent alert client at each telescope, it can analyze and respond to each distributed TALON alert based on the telescopes needs and schedule.

  19. TALON: the telescope alert operation network system: intelligent linking of distributed autonomous robotic telescopes

    NASA Astrophysics Data System (ADS)

    White, Robert R.; Wren, James; Davis, Heath R.; Galassi, Mark; Starr, Daniel; Vestrand, W. T.; Wozniak, P.

    2004-09-01

    The internet has brought about great change in the astronomical community, but this interconnectivity is just starting to be exploited for use in instrumentation. Utilizing the internet for communicating between distributed astronomical systems is still in its infancy, but it already shows great potential. Here we present an example of a distributed network of telescopes that performs more efficiently in synchronous operation than as individual instruments. RAPid Telescopes for Optical Response (RAPTOR) is a system of telescopes at LANL that has intelligent intercommunication, combined with wide-field optics, temporal monitoring software, and deep-field follow-up capability all working in closed-loop real-time operation. The Telescope ALert Operations Network (TALON) is a network server that allows intercommunication of alert triggers from external and internal resources and controls the distribution of these to each of the telescopes on the network. TALON is designed to grow, allowing any number of telescopes to be linked together and communicate. Coupled with an intelligent alert client at each telescope, it can analyze and respond to each distributed TALON alert based on the telescopes needs and schedule.

  20. Environment Agency England flood warning systems

    NASA Astrophysics Data System (ADS)

    Strong, Chris; Walters, Mark; Haynes, Elizabeth; Dobson, Peter

    2015-04-01

    Context In England around 5 million homes are at risk of flooding. We invest significantly in flood prevention and management schemes but we can never prevent all flooding. Early alerting systems are fundamental to helping us reduce the impacts of flooding. The Environment Agency has had the responsibility for flood warning since 1996. In 2006 we invested in a new dissemination system that would send direct messages to pre-identified recipients via a range of channels. Since then we have continuously improved the system and service we offer. In 2010 we introduced an 'opt-out' service where we pre-registered landline numbers in flood risk areas, significantly increasing the customer base. The service has performed exceptionally well under intense flood conditions. Over a period of 3 days in December 2013, when England was experiencing an east coast storm surge, the system sent nearly 350,000 telephone messages, 85,000 emails and 70,000 text messages, with a peak call rate of around 37,000 per hour and 100% availability. The Floodline Warnings Direct (FWD) System FWD provides warnings in advance of flooding so that people at risk and responders can take action to minimise the impact of the flood. Warnings are sent via telephone, fax, text message, pager or e-mail to over 1.1 million properties located within flood risk areas in England. Triggers for issuing alerts and warnings include attained and forecast river levels and rainfall in some rapidly responding locations. There are three levels of warning: Flood Alert, Flood Warning and Severe Flood Warning, and a stand down message. The warnings can be updated to include relevant information to help inform those at risk. Working with our current provider Fujitsu, the system is under a programme of continuous improvement including expanding the 'opt-out' service to mobile phone numbers registered to at risk addresses, allowing mobile registration to the system for people 'on the move' and providing access to

  1. A fresh look at runway incursions: onboard surface movement awareness and alerting system based on SVS

    NASA Astrophysics Data System (ADS)

    Vernaleken, Christoph; Mihalic, Lamir; Güttler, Mathias; Klingauf, Uwe

    2006-05-01

    Increasing traffic density on the aerodrome surface due to the continuous worldwide growth in the number of flight operations does not only cause capacity and efficiency problems, but also increases the risk of serious incidents and accidents on the airport movement area. Of these, Runway Incursions are the by far most safety-critical. In fact, the worst-ever accident in civil aviation, the collision of two Boeing B747s on Tenerife in 1977 with 583 fatalities, was caused by a Runway Incursion. Therefore, various Runway Safety programs have recently been initiated around the globe, often focusing on ground-based measures such as improved surveillance. However, as a lack of flight crew situational awareness is a key causal factor in many Runway Incursion incidents and accidents, there is a strong need for an onboard solution, which should be capable of interacting cooperatively with ground-based ATM systems, such as A-SMGCS where available. This paper defines the concept of preventive and reactive Runway Incursion avoidance and describes a Surface Movement Awareness & Alerting System (SMAAS) designed to alert the flight crew if they are at risk of infringing a runway. Both the SVS flight deck displays and the corresponding alerting algorithms utilize an ED 99A/RTCA DO-272A compliant aerodrome database, as well as airport operational, traffic and clearance data received via ADS-B or other data links, respectively. The displays provide the crew with enhanced positional, operational, clearance and traffic awareness, and they are used to visualize alerts. A future enhancement of the system will provide intelligent alerting for conflicts caused by surrounding traffic.

  2. 21 CFR Appendix E to Subpart A of... - Elements To Be Considered in Developing a Two-Way Alert System

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING... Considered in Developing a Two-Way Alert System 1. Documentation —Definition of a crisis/emergency and under what circumstances an alert is required —Standard Operating Procedures (SOP's) —Mechanism of...

  3. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... broadcast networks, cable networks and program suppliers; and other entities and industries operating on an... transmission of data such as interactive games. Wireless Cable Systems (BRS/EBS STATIONS) System Size and... EAS message. Note: Programmed channels do not include channels used for the transmission of...

  4. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Video interrupt must cause all channels that carry programming to flash for the duration of the EAS... transmission of data such as interactive games. Wireless Cable Systems (BRS/EBS STATIONS) System Size and... all channels that carry programming to flash for the duration of the EAS emergency message. The...

  5. Chemical Safety Alert: Fire Hazard from Carbon Adsorption Deodorizing Systems

    EPA Pesticide Factsheets

    Activated carbon systems used to adsorb vapors for odor control may pose a fire hazard when used for certain types of substances, such as crude sulfate turpentine. Facilities should take precautions and proper procedures to avoid or mitigate these hazards.

  6. Maintained effectiveness of an electronic alert system to prevent venous thromboembolism among hospitalized patients.

    PubMed

    Lecumberri, Ramón; Marqués, Margarita; Díaz-Navarlaz, María Teresa; Panizo, Elena; Toledo, Jon; García-Mouriz, Alberto; Páramo, José A

    2008-10-01

    Despite current guidelines, venous thromboembolism (VTE) prophylaxis is underused. Computerized programs to encourage physicians to apply thromboprophylaxis have been shown to be effective in selected populations. Our aim was to analyze the impact of the implementation of a computer-alert system for VTE risk in all hospitalized patients of a teaching hospital. A computer program linked to the clinical record database was developed to assess all hospitalized patients' VTE risk daily. The physician responsible for patients at high risk was alerted, but remained free to order or withhold prophylaxis. Over 19,000 hospitalized, medical and surgical, adult patients between January to June 2005 (pre-intervention phase), January to June 2006 and January to June 2007 (post-intervention phase), were included. During the first semesters of 2006 and 2007, an electronic alert was sent to 32.8% and 32.2% of all hospitalized patients, respectively. Appropriate prophylaxis among alerted patients was ordered in 89.7% (2006) and 88.5% (2007) of surgical patients, and in 49.2% (2006) and 64.4% (2007) of medical patients. A sustained reduction of VTE during hospitalization was achieved, Odds ratio (OR): 0.53, 95% confidence interval (CI) (0.25-1.10) and OR: 0.51, 95%CI (0.24-1.05) during the first semesters of 2006 and 2007 respectively, the impact being significant (p < 0.05) among medical patients in 2007, OR: 0.36, 95%CI (0.12-0.98). The implementation of a computer-alert program helps physicians to assess each patient's thrombotic risk, leading to a better use of thromboprophylaxis, and a reduction in the incidence of VTE among hospitalized patients. For the first time, an intervention aimed to improve VTE prophylaxis shows maintained effectiveness over time.

  7. Maximizing Trust in the Wireless Emergency Alerts (WEA) Service

    DTIC Science & Technology

    2014-02-01

    CMAS). Alert originators (AOs) at emer- gency management agencies ( EMAs ) must trust WEA to deliver alerts to the public in an accurate and timely...that they receive before they will act on them. Clearly, the AOs, the EMAs , and the Federal Emergency Management Agency (FEMA) must all strive to...some factors, such as security, FEMA has requirements that an EMA and its contractors must satisfy. System reliability is a shared responsibility as it

  8. A low-cost wireless system for autonomous generation of road safety alerts

    NASA Astrophysics Data System (ADS)

    Banks, B.; Harms, T.; Sedigh Sarvestani, S.; Bastianini, F.

    2009-03-01

    This paper describes an autonomous wireless system that generates road safety alerts, in the form of SMS and email messages, and sends them to motorists subscribed to the service. Drivers who regularly traverse a particular route are the main beneficiaries of the proposed system, which is intended for sparsely populated rural areas, where information available to drivers about road safety, especially bridge conditions, is very limited. At the heart of this system is the SmartBrick, a wireless system for remote structural health monitoring that has been presented in our previous work. Sensors on the SmartBrick network regularly collect data on water level, temperature, strain, and other parameters important to safety of a bridge. This information is stored on the device, and reported to a remote server over the GSM cellular infrastructure. The system generates alerts indicating hazardous road conditions when the data exceeds thresholds that can be remotely changed. The remote server and any number of designated authorities can be notified by email, FTP, and SMS. Drivers can view road conditions and subscribe to SMS and/or email alerts through a web page. The subscription-only form of alert generation has been deliberately selected to mitigate privacy concerns. The proposed system can significantly increase the safety of travel through rural areas. Real-time availability of information to transportation authorities and law enforcement officials facilitates early or proactive reaction to road hazards. Direct notification of drivers further increases the utility of the system in increasing the safety of the traveling public.

  9. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... stations including AM, FM, and Low-power FM (LPFM) stations; digital audio broadcasting (DAB) stations, including digital AM, FM, and Low-power FM stations; Class A television (CA) and Low-power TV (LPTV... Unidirectional Digital Cable Product or other navigation device; wireline video systems; wireless cable...

  10. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... stations including AM, FM, and Low-power FM (LPFM) stations; digital audio broadcasting (DAB) stations, including digital AM, FM, and Low-power FM stations; Class A television (CA) and Low-power TV (LPTV... Unidirectional Digital Cable Product or other navigation device; wireline video systems; wireless cable...

  11. Enterprise-wide drug-drug interaction alerting system.

    PubMed

    Greim, Julie A; Shek, Caroline; Jones, Linda; Macauley, Robert; Paterno, Marilyn; Blumenfeld, Barry H; Kuperman, Gilad

    2003-01-01

    According to the Institute of Medicine's (IOM) 1999 report To Err is Human: Building a safer Health System, "medical errors kill some 44,000-98,0001 people in U.S. hospitals each year. Partners HealthCare System (PHS) is a large integrated delivery network in Boston, MA, which has as a goal improving patient care by preventing adverse drug events (ADE) and reducing medication errors enterprise-wide. PHS has developed a drug-drug Interaction (DDI) detection feature, for the suite of clinical applications currently used by its two major teaching institutions, Brigham & Women's Hospital (BWH) and Mass General Hospital (MGH). The following clinical applications will be using this drug-drug interaction feature: NICU Order Entry (OE) at BWH, MGH OE for pediatrics and adults, the Partners outpatient medical record, The LMR, and BICS OE at BWH.

  12. Real Time View of the Functions and Services of the Seismic Alert System of Mexico (SASMEX)

    NASA Astrophysics Data System (ADS)

    Espinosa Aranda, J.; Ibarrola Alvarez, G.; Cuellar Martinez, A.; Inostroza Puk, M.

    2013-05-01

    The Seismic Alert System of Mexico (SASMEX) is integrated since March 2012 by the Seismic Alert System of Mexico City (SAS), in continuous operation since 1991, and the Seismic Alert System of Oaxaca City (SASO) that started its services in 2003. SASMEX consists of 97 field seismic sensor station (FS) type triaxial accelerometer, mostly sponsored by the government of Mexico City and secondly by Oaxaca. The SASMEX covers the Pacific seismic hazard among the coast of Jalisco, Colima, Michoacan, Guerrero and Oaxaca; and the seismic region of Puebla and northern Oaxaca and Guerrero states. This integration lets to warn with better opportunity to the population of Mexico City, Oaxaca Oax., Acapulco Gro., Chilpancingo Gro. and recently Morelia Mich.; cities with a system called EASAS where receives seismic data from FS and emits earthquake early warning signals to the population. The recent sponsorship of Federal Government through the General Coordination of Civil Protection and the National Center for Disaster Prevention, reinforced integration SAS and SASO, and auspiced the development of a Real-Time Monitoring System of functions and services of SASMEX. This work show how is displayed the functions of services of SASMEX through this monitoring system and its possible application by Civil Protection authorities. This monitoring system can indicate the status of FS, the communications system and cities with EASAS. Additionally, when an earthquake occurs and is detected by the SASMEX, the monitoring system shows the messages of FS, whose consist in the characteristics of detection and seismic danger forecasted; in the case of a strong earthquake estimated by more than one FS, the EASAS of each city could automatically issue an Alert Public to its population. The monitoring system allows observing cities with EASAS that activate their alerts, displays a basic earthquake propagation model and how it reaches to other FS. Additionally, the monitoring system shows the

  13. The Hub Population Health System: distributed ad hoc queries and alerts.

    PubMed

    Buck, Michael D; Anane, Sheila; Taverna, John; Amirfar, Sam; Stubbs-Dame, Remle; Singer, Jesse

    2012-06-01

    The Hub Population Health System enables the creation and distribution of queries for aggregate count information, clinical decision support alerts at the point-of-care for patients who meet specified conditions, and secure messages sent directly to provider electronic health record (EHR) inboxes. Using a metronidazole medication recall, the New York City Department of Health was able to determine the number of affected patients and message providers, and distribute an alert to participating practices. As of September 2011, the system is live in 400 practices and within a year will have over 532 practices with 2500 providers, representing over 2.5 million New Yorkers. The Hub can help public health experts to evaluate population health and quality improvement activities throughout the ambulatory care network. Multiple EHR vendors are building these features in partnership with the department's regional extension center in anticipation of new meaningful use requirements.

  14. Utility of an integrated electronic suicide alert system in a psychiatric hospital.

    PubMed

    Madan, Alok; Mahoney, Jane; Allen, Jon G; Ellis, Thomas; Hardesty, Susan; Oldham, John M; Fowler, J Christopher

    2015-01-01

    Management of suicide-related behaviors in a hospital is challenging. This article (1) describes integration of an electronic suicide risk notification system to improve assessment of psychiatric inpatients, (2) details the manner in which these alerts complement standard of care, and (3) provides support of using aggregate data to inform administrative decision-making. Complementing routine clinical care and under the supervision of an assessment coordinator, adult inpatients at a specialty psychiatric hospital complete a computerized battery of outcome assessments throughout the course of their hospitalization. A critical-item response notification system for suicide-related behaviors was implemented within the larger, assessment architecture, sending an alert e-mail to unit staff if patients endorsed suicidal ideation on any 1 of 6 critical items. Analysis of aggregate data over a 19-month period reveal a linear trend of increasing rate of suicide alerts from October 2012 to April 2013 (Phase A) with a stabilization at the heightened level from July 2013 to April 2014 (Phase B), R = 0.697, P = .007. Findings suggest that more nuanced training in the management of suicide-related behavior may be necessary and that traditional approaches to staffing may need to accommodate patient acuity. The communication innovation of this system is in line with the Joint Commission's emphasis on designing and implementing patient-centered systems that enhance quality of care, including improved safety.

  15. AGILE/GRID Science Alert Monitoring System: The Workflow and the Crab Flare Case

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Conforti, V.; Parmiggiani, N.

    2013-10-01

    During the first five years of the AGILE mission we have observed many gamma-ray transients of Galactic and extragalactic origin. A fast reaction to unexpected transient events is a crucial part of the AGILE monitoring program, because the follow-up of astrophysical transients is a key point for this space mission. We present the workflow and the software developed by the AGILE Team to perform the automatic analysis for the detection of gamma-ray transients. In addition, an App for iPhone will be released enabling the Team to access the monitoring system through mobile phones. In 2010 September the science alert monitoring system presented in this paper recorded a transient phenomena from the Crab Nebula, generating an automated alert sent via email and SMS two hours after the end of an AGILE satellite orbit, i.e. two hours after the Crab flare itself: for this discovery AGILE won the 2012 Bruno Rossi prize. The design of this alert system is maximized to reach the maximum speed, and in this, as in many other cases, AGILE has demonstrated that the reaction speed of the monitoring system is crucial for the scientific return of the mission.

  16. ALERTES-SC3 Early Warning System prototype for South Iberian Peninsula: on-site approach.

    NASA Astrophysics Data System (ADS)

    Pazos, Antonio; Lopez de Mesa, Mireya; Gallego Carrasco, Javier; Martín Davila, José; Rioja del Rio, Carlos; Morgado, Arturo; Vera, Angel; Ciberia, Angel; Cabieces, Roberto; Strollo, Angelo; Hanka, Winfried; Carranza, Marta

    2016-04-01

    In recent years several Earthquake Early Warning Systems (EEWS) have been developed for different parts of the world. The area between SW Cape St. Vicente and the Strait of Gibraltar is one of the most seismically active zones in the Ibero-Maghrebian region, with predominantly moderate and superficial seismicity, but also big events with associated tsunamis are well documented in the area, like the 1755 Lisbon earthquake. In the frame of the ALERT-ES (2011-2013) and ALERTES-RIM (2014-2016) Spanish projects, the ALERTES-SC3 EEWS, regional approach, prototype has been developed at the Royal Spanish Navy Observatory (ROA) and is being tested in near real time for south Iberia. This prototype, based on the SeisComP3 software package, is largely based on algorithms derived from the analysis of the first seconds of the P wave records. Calculation of several parameters are carried out, mainly the characteristic period (τc) and the displacement peak (Pd), but also the velocity peak (Pv), the maximum period (τPmáx), among others. In order to warm the areas closest to the hypocentre, places located inside the "blind zone", a on-site EEWS has also been developed by ROA and integrated in the ALERTES-SC3 prototype. From the on-site approach, a warm level is declared from one station as a function of the estimated characteristic period (τc) and the displacement Peak (Pd), although the earthquake location and therefore the lead time available remains unknown. This on-site EEWS is being tested in several Western Mediterranean net (WM) stations as ARNO (Arenosillo, Huelva,Spain) or CHAS (Chafarinas island, North Africa, Spain). Also an on-site low cost station is being developed based in low cost accelerometers. In this work the current state of the on-site EEWS developed, its integration in the ALERTES-SC3 EEWS system and the low cost seismic stations are shown.

  17. Volcanic Alert System (VAS) developed during the (2011-2013) El Hierro (Canary Islands) volcanic process

    NASA Astrophysics Data System (ADS)

    Ortiz, Ramon; Berrocoso, Manuel; Marrero, Jose Manuel; Fernandez-Ros, Alberto; Prates, Gonçalo; De la Cruz-Reyna, Servando; Garcia, Alicia

    2014-05-01

    In volcanic areas with long repose periods (as El Hierro), recently installed monitoring networks offer no instrumental record of past eruptions nor experience in handling a volcanic crisis. Both conditions, uncertainty and inexperience, contribute to make the communication of hazard more difficult. In fact, in the initial phases of the unrest at El Hierro, the perception of volcanic risk was somewhat distorted, as even relatively low volcanic hazards caused a high political impact. The need of a Volcanic Alert System became then evident. In general, the Volcanic Alert System is comprised of the monitoring network, the software tools for the analysis of the observables, the management of the Volcanic Activity Level, and the assessment of the threat. The Volcanic Alert System presented here places special emphasis on phenomena associated to moderate eruptions, as well as on volcano-tectonic earthquakes and landslides, which in some cases, as in El Hierro, may be more destructive than an eruption itself. As part of the Volcanic Alert System, we introduce here the Volcanic Activity Level which continuously applies a routine analysis of monitoring data (particularly seismic and deformation data) to detect data trend changes or monitoring network failures. The data trend changes are quantified according to the Failure Forecast Method (FFM). When data changes and/or malfunctions are detected, by an automated watchdog, warnings are automatically issued to the Monitoring Scientific Team. Changes in the data patterns are then translated by the Monitoring Scientific Team into a simple Volcanic Activity Level, that is easy to use and understand by the scientists and technicians in charge for the technical management of the unrest. The main feature of the Volcanic Activity Level is its objectivity, as it does not depend on expert opinions, which are left to the Scientific Committee, and its capabilities for early detection of precursors. As a consequence of the El Hierro

  18. Passive pavement-mounted acoustical linguistic drive alert system and method

    DOEpatents

    Kisner, Roger A.; Anderson, Richard L.; Carnal, Charles L.; Hylton, James O.; Stevens, Samuel S.

    2001-01-01

    Systems and methods are described for passive pavement-mounted acoustical alert of the occupants of a vehicle. A method of notifying a vehicle occupant includes providing a driving medium upon which a vehicle is to be driven; and texturing a portion of the driving medium such that the textured portion interacts with the vehicle to produce audible signals, the textured portion pattern such that a linguistic message is encoded into the audible signals. The systems and methods provide advantages because information can be conveyed to the occupants of the vehicle based on the location of the vehicle relative to the textured surface.

  19. Wireless Emergency Alerts: Trust Model Simulations

    DTIC Science & Technology

    2014-02-01

    service, for- merly known as the Commercial Mobile Alert Service (CMAS). Alert originators (AOs) working at emergency management agencies ( EMAs ...Emergency Management Agency (FEMA), the EMAs , and the AOs must all strive to maximize and maintain trust in the WEA ser- vice if it is to be an effective...Alert Service (CMAS), enhances public safety by providing authorized emergency management agen- cies ( EMAs ) with the capability to issue alerts and

  20. The Impact of a Traffic Alert and Collision Avoidance System on the Air Traffic Control Radar Beacon System and Mode S System in the Los Angeles Basin.

    DTIC Science & Technology

    1985-05-01

    FAAIPM-84130 The Impact of a Traffic Alert and Program Engineering Collision Avoidance System on the and Maintenance Service Air Traffic Control Radar...ON4 THE AIR TRAFFIC CONTROL RADAR BEACON SYSTEM 6.~ eforming organization Cede AND THE MODE :3 SYSTEM IN THE LOS ANGELES BASIN P032 7 A~,re~lIS...performed to predict the impact of the Traffic Alert and Collision Avoidance System (TCAS) on the performance of selected air traffic control and surveil

  1. A real-time hybrid aurora alert system: Combining citizen science reports with an auroral oval model

    NASA Astrophysics Data System (ADS)

    Case, N. A.; Kingman, D.; MacDonald, E. A.

    2016-06-01

    Accurately predicting when, and from where, an aurora will be visible is particularly difficult, yet it is a service much desired by the general public. Several aurora alert services exist that attempt to provide such predictions but are, generally, based upon fairly coarse estimates of auroral activity (e.g., Kp or Dst). Additionally, these services are not able to account for a potential observer's local conditions (such as cloud cover or level of darkness). Aurorasaurus, however, combines data from the well-used, solar wind-driven, OVATION Prime auroral oval model with real-time observational data provided by a global network of citizen scientists. This system is designed to provide more accurate and localized alerts for auroral visibility than currently available. Early results are promising and show that over 100,000 auroral visibility alerts have been issued, including nearly 200 highly localized alerts, to over 2000 users located right across the globe.

  2. U.S. Geological Survey's Alert Notification System for Volcanic Activity

    USGS Publications Warehouse

    Gardner, Cynthia A.; Guffanti, Marianne C.

    2006-01-01

    The United States and its territories have about 170 volcanoes that have been active during the past 10,000 years, and most could erupt again in the future. In the past 500 years, 80 U.S. volcanoes have erupted one or more times. About 50 of these recently active volcanoes are monitored, although not all to the same degree. Through its five volcano observatories, the U.S. Geological Survey (USGS) issues information and warnings to the public about volcanic activity. For clarity of warnings during volcanic crises, the USGS has now standardized the alert-notification system used at its observatories.

  3. ROA's Real time GNSS network and its viability in Alertes-RIM system

    NASA Astrophysics Data System (ADS)

    Cibeira Urtiaga, Ángel; Gárate, Jorge; Mendoza, Leonor

    2015-04-01

    San Fernando Naval Observatory deployed a Geodetic Continuous GNSS network from the mid nineties. The most of the sites are located in the South of the Iberian Peninsula. Nowadays time series of several years for the most of these sites are available. This is the most risky region in the peninsula due to the confrontation of two tectonic plates, i.e. Euro-Asiatic and African Plates. The former confrontation generated several faults, origin of important earthquakes (e.g. the big earthquake of Lisbon in 1775, whose epicenter was located in the Azores-Gibraltar fault, where Euro-Asiatic and African plates collide). In order to prevent higher aftermaths, the San Fernando Naval Observatory with the University of Cádiz and the University Complutense of Madrid, started to develop an early warning system, based on the study of the P waves, with the result of a prototype known as Alertes system. In early 2014 an improvement of the Alertes-RIM system began, introducing the study of viability of using high frequency geodetic GNSS signals in real time and others, looking for an improvement in the time of response in the previous instants of an earthquake. This project is still on process of development.

  4. Alertness - decreased

    MedlinePlus

    ... alertness, including: Chronic kidney disease Extreme tiredness or lack of sleep High blood sugar level or low blood sugar ... or breathing problems, such as: Abnormal heart rhythm Lack of ... medicines Side effect of almost any medicine, such as those used ...

  5. Head Mounted Alerting for Urban Operations via Tactical Information Management System

    DTIC Science & Technology

    2006-03-01

    experiments. Voice synthesis tools were used to create consistent voice-based audio alerts. It was found that synthesized voice alerts were less...speech synthesizer to implement text to speech amplification4. It was found that the use of automated text-to-speech synthesis produced less distracting...prerecorded using a few different speech synthesis packages. Alert severity and soldier activity level were hard-coded based on the best assessment of

  6. Alert Confidence Fusion in Intrusion Detection Systems with Extended Dempster- Shafer Theory

    SciTech Connect

    Yu, Dong; Frincke, Deborah A.

    2005-03-01

    Extend Dempster-Shafer Theory of Evidence to include differential weightings of alerts drawn from multiple sources. The intent is to support automated (and manual) response to threat by producing more realistic confidence ratings for IDS alerts than is currently available.

  7. Controlled Evaluation of the New BacT/Alert Virtuo Blood Culture System for Detection and Time to Detection of Bacteria and Yeasts

    PubMed Central

    Almuhayawi, Mohammed; Lüthje, Petra; Taha, Rubina; Ullberg, Måns; Özenci, Volkan

    2016-01-01

    We compared the newly approved BacT/Alert Virtuo blood culture system to the BacT/Alert 3D system using 115 clinical bacterial and fungal isolates in 784 simulated blood culture bottles. The time to detection was reduced by roughly 20% in the Virtuo system (P < 0.0001) while the detection rate did not differ. PMID:26842707

  8. A volcanic activity alert-level system for aviation: review of its development and application in Alaska

    USGS Publications Warehouse

    2013-01-01

    An alert-level system for communicating volcano hazard information to the aviation industry was devised by the Alaska Volcano Observatory (AVO) during the 1989–1990 eruption of Redoubt Volcano. The system uses a simple, color-coded ranking that focuses on volcanic ash emissions: Green—normal background; Yellow—signs of unrest; Orange—precursory unrest or minor ash eruption; Red—major ash eruption imminent or underway. The color code has been successfully applied on a regional scale in Alaska for a sustained period. During 2002–2011, elevated color codes were assigned by AVO to 13 volcanoes, eight of which erupted; for that decade, one or more Alaskan volcanoes were at Yellow on 67 % of days and at Orange or Red on 12 % of days. As evidence of its utility, the color code system is integrated into procedures of agencies responsible for air-traffic management and aviation meteorology in Alaska. Furthermore, it is endorsed as a key part of globally coordinated protocols established by the International Civil Aviation Organization to provide warnings of ash hazards to aviation worldwide. The color code and accompanying structured message (called a Volcano Observatory Notice for Aviation) comprise an effective early-warning message system according to the United Nations International Strategy for Disaster Reduction. The aviation color code system currently is used in the United States, Russia, New Zealand, Iceland, and partially in the Philippines, Papua New Guinea, and Indonesia. Although there are some barriers to implementation, with continued education and outreach to Volcano Observatories worldwide, greater use of the aviation color code system is achievable.

  9. Implementation of an alert and response system in Haiti during the early stage of the response to the cholera epidemic.

    PubMed

    Santa-Olalla, Patricia; Gayer, Michelle; Magloire, Roc; Barrais, Robert; Valenciano, Marta; Aramburu, Carmen; Poncelet, Jean Luc; Gustavo Alonso, Juan Carlos; Van Alphen, Dana; Heuschen, Florence; Andraghetti, Roberta; Lee, Robert; Drury, Patrick; Aldighieri, Sylvain

    2013-10-01

    The start of the cholera epidemic in Haiti quickly highlighted the necessity of the implementation of an Alert and Response (A&R) System to complement the existing national surveillance system. The national system had been able to detect and confirm the outbreak etiology but required external support to monitor the spread of cholera and coordinate response, because much of the information produced was insufficiently timely for real-time monitoring and directing of a rapid, targeted response. The A&R System was designed by the Pan American Health Organization/World Health Organization in collaboration with the Haiti Ministry of Health, and it was based on a network of partners, including any institution, structure, or individual that could identify, verify, and respond to alerts. The defined objectives were to (1) save lives through early detection and treatment of cases and (2) control the spread through early intervention at the community level. The operational structure could be broken down into three principle categories: (1) alert (early warning), (2) verification and assessment of the information, and (3) efficient and timely response in coordination with partners to avoid duplication. Information generated by the A&R System was analyzed and interpreted, and the qualitative information was critical in qualifying the epidemic and defining vulnerable areas, particularly because the national surveillance system reported incomplete data for more than one department. The A&R System detected a number of alerts unrelated to cholera and facilitated rapid access to that information. The sensitivity of the system and its ability to react quickly was shown in May of 2011, when an abnormal increase in alerts coming from several communes in the Sud-Est Department in epidemiological weeks (EWs) 17 and 18 were noted and disseminated network-wide and response activities were implemented. The national cholera surveillance system did not register the increase until EWs 21 and

  10. Implementation of an Alert and Response System in Haiti during the Early Stage of the Response to the Cholera Epidemic

    PubMed Central

    Santa-Olalla, Patricia; Gayer, Michelle; Magloire, Roc; Barrais, Robert; Valenciano, Marta; Aramburu, Carmen; Poncelet, Jean Luc; Gustavo Alonso, Juan Carlos; Van Alphen, Dana; Heuschen, Florence; Andraghetti, Roberta; Lee, Robert; Drury, Patrick; Aldighieri, Sylvain

    2013-01-01

    The start of the cholera epidemic in Haiti quickly highlighted the necessity of the implementation of an Alert and Response (A&R) System to complement the existing national surveillance system. The national system had been able to detect and confirm the outbreak etiology but required external support to monitor the spread of cholera and coordinate response, because much of the information produced was insufficiently timely for real-time monitoring and directing of a rapid, targeted response. The A&R System was designed by the Pan American Health Organization/World Health Organization in collaboration with the Haiti Ministry of Health, and it was based on a network of partners, including any institution, structure, or individual that could identify, verify, and respond to alerts. The defined objectives were to (1) save lives through early detection and treatment of cases and (2) control the spread through early intervention at the community level. The operational structure could be broken down into three principle categories: (1) alert (early warning), (2) verification and assessment of the information, and (3) efficient and timely response in coordination with partners to avoid duplication. Information generated by the A&R System was analyzed and interpreted, and the qualitative information was critical in qualifying the epidemic and defining vulnerable areas, particularly because the national surveillance system reported incomplete data for more than one department. The A&R System detected a number of alerts unrelated to cholera and facilitated rapid access to that information. The sensitivity of the system and its ability to react quickly was shown in May of 2011, when an abnormal increase in alerts coming from several communes in the Sud-Est Department in epidemiological weeks (EWs) 17 and 18 were noted and disseminated network-wide and response activities were implemented. The national cholera surveillance system did not register the increase until EWs 21 and

  11. Making the Most of Alert Notification Systems: Eleven Tips for Using Emergency Communication Solutions in Your District

    ERIC Educational Resources Information Center

    Riley, Sheila

    2007-01-01

    Districts are finding that alert notification systems that deliver automated phone messages are an effective way to reach parents and employees. Implementing the technology is one thing and getting the most out of it is another. This article presents the Districts' goal to get in touch with parents and employees in emergency situations. Andy…

  12. ATR-Hanford site emergency alerting system -- 400 Area (F1-F2) and 600 Area (S6-S10)

    SciTech Connect

    Whattam, J.W.

    1998-05-28

    This document provides the results of the acceptance test procedure performed under document number: HNF-2501, Rev 0. This Acceptance Test Procedure has been prepared to demonstrate the Hanford Site Emergency Alerting System functions as required by Specification WHC-S0454, Rev. 1 and project criteria.

  13. 78 FR 22270 - Special Fraud Alert: Physician-Owned Entities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ... HUMAN SERVICES Office of Inspector General Special Fraud Alert: Physician-Owned Entities AGENCY: Office... issued Special Fraud Alert on Physician-Owned Entities. Specifically, the Special Fraud Alert addressed... INFORMATION: In our publication of the Special Fraud Alert on Physician-Owned Entities, an inadvertent...

  14. Design and implementation of a marine animal alert system to support Marine Renewable Energy

    SciTech Connect

    Deng, Zhiqun; Carlson, Thomas J.; Fu, Tao; Ren, Huiying; Martinez, Jayson J.; Myers, Joshua R.; Matzner, Shari; Choi, Eric Y.; Copping, Andrea E.

    2013-08-08

    Power extracted from fast moving tidal currents has been identified as a potential commercial-scale source of renewable energy. Device developers and utilities are pursuing deployment of prototype tidal turbines to assess technology viability, site feasibility, and environmental interactions. Deployment of prototype turbines requires permits from a range of regulatory authorities. Ensuring the safety of marine animals, particularly those under protection of the Endangered Species Act of 1973 (ESA) and the Marine Mammal Protection Act of 1972 has emerged as a key regulatory challenge for initial MHK deployments. The greatest perceived risk to marine animals is from strike by the rotating blades of tidal turbines. Development of the marine mammal alert system (MAAS) was undertaken to support monitoring and mitigation requirements for tidal turbine deployments. The prototype system development focused on Southern Resident killer whales (SRKW), an endangered population of killer whales that frequents Puget Sound and is intermittently present in the part of the sound where deployment of prototype tidal turbines is being considered. Passive acoustics were selected as the primary means because of the vocal nature of these animals. The MAAS passive acoustic system consists of two-stage process involving the use of an energy detector and a spectrogram-based classifier to distinguish between SKRW’s calls and noise. A prototype consisting of two 2D symmetrical star arrays separated by 20 m center to center was built and evaluated in the waters of Sequim Bay using whale call playback.

  15. 76 FR 54245 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, Integrated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... Review; Comment Request, Integrated Public Alert and Warning Systems (IPAWS) Inventory AGENCY: Federal..., integrated, flexible, and comprehensive system to alert and warn the American people in situations of war... requires that DHS establish an inventory of public alert and warning resources, capabilities, and...

  16. 76 FR 32367 - Agency Information Collection Activities, Proposed Collection; Comment Request; Integrated Public...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-06

    ...; Comment Request; Integrated Public Alert and Warning Systems (IPAWS) Inventory AGENCY: Federal Emergency... proposed revision of the information collection concerning public alert and warning systems at the Federal... evaluation and assessment of existing public alert and warning resources and their integration with...

  17. Volcanic alert system (VAS) developed during the 2011-2014 El Hierro (Canary Islands) volcanic process

    NASA Astrophysics Data System (ADS)

    García, Alicia; Berrocoso, Manuel; Marrero, José M.; Fernández-Ros, Alberto; Prates, Gonçalo; De la Cruz-Reyna, Servando; Ortiz, Ramón

    2014-06-01

    The 2011 volcanic unrest at El Hierro Island illustrated the need for a Volcanic Alert System (VAS) specifically designed for the management of volcanic crises developing after long repose periods. The VAS comprises the monitoring network, the software tools for analysis of the monitoring parameters, the Volcanic Activity Level (VAL) management, and the assessment of hazard. The VAS presented here focuses on phenomena related to moderate eruptions, and on potentially destructive volcano-tectonic earthquakes and landslides. We introduce a set of new data analysis tools, aimed to detect data trend changes, as well as spurious signals related to instrumental failure. When data-trend changes and/or malfunctions are detected, a watchdog is triggered, issuing a watch-out warning (WOW) to the Monitoring Scientific Team (MST). The changes in data patterns are then translated by the MST into a VAL that is easy to use and understand by scientists, technicians, and decision-makers. Although the VAS was designed specifically for the unrest episodes at El Hierro, the methodologies may prove useful at other volcanic systems.

  18. Enhanced 911/global position system wizard: a telemedicine application for the prevention of severe hypoglycemia--monitor, alert, and locate.

    PubMed

    Dassau, Eyal; Jovanovic, Lois; Doyle, Francis J; Zisser, Howard C

    2009-11-01

    Intensive insulin therapy has an inherent risk of hypoglycemia that can lead to loss of consciousness, cardiac arrhythmia, seizure, and death ("dead-in-bed syndrome"). This risk of hypoglycemia is a major concern for patients, families, and physicians. The need for an automated system that can alert in the event of severe hypoglycemia is evident. In engineering systems, where there is a risk of malfunction of the primary control system, alert and safety mechanisms are implemented in layers of protection. This concept has been adopted in the proposed system that integrates a hypoglycemia prediction algorithm with a global position system (GPS) locator and short message service such that the current glucose value with the rate of change (ROC) and the location of the subject can be communicated to a predefined list. Furthermore, if the system is linked to the insulin pump, it can suspend the pump or decrease the basal insulin infusion rate to prevent the pending event. The system was evaluated on clinical datasets of glucose tracings from the DexCom Seven system. Glucose tracings were analyzed for hypoglycemia events and then a text message was broadcast to a predefined list of people who were notified with the glucose value, ROC, GPS coordinates, and a Google map of the location. In addition to providing a safety layer to a future artificial pancreas, this system also can be easily implemented in current continuous glucose monitors to help provide information and alerts to people with diabetes.

  19. Mexican Seismic Alert System's SAS-I algorithm review considering strong earthquakes felt in Mexico City since 1985

    NASA Astrophysics Data System (ADS)

    Cuellar Martinez, A.; Espinosa Aranda, J.; Suarez, G.; Ibarrola Alvarez, G.; Ramos Perez, S.; Camarillo Barranco, L.

    2013-05-01

    The Seismic Alert System of Mexico (SASMEX) uses three algorithms for alert activation that involve the distance between the seismic sensing field station (FS) and the city to be alerted; and the forecast for earthquake early warning activation in the cities integrated to the system, for example in Mexico City, the earthquakes occurred with the highest accelerations, were originated in the Pacific Ocean coast, whose distance this seismic region and the city, favors the use of algorithm called Algorithm SAS-I. This algorithm, without significant changes since its beginning in 1991, employs the data that generate one or more FS during P wave detection until S wave detection plus a period equal to the time employed to detect these phases; that is the double S-P time, called 2*(S-P). In this interval, the algorithm performs an integration process of quadratic samples from FS which uses a triaxial accelerometer to get two parameters: amplitude and growth rate measured until 2*(S-P) time. The parameters in SAS-I are used in a Magnitude classifier model, which was made from Guerrero Coast earthquakes time series, with reference to Mb magnitude mainly. This algorithm activates a Public or Preventive Alert if the model predicts whether Strong or Moderate earthquake. The SAS-I algorithm has been operating for over 23 years in the subduction zone of the Pacific Coast of Mexico, initially in Guerrero and followed by Oaxaca; and since March 2012 in the seismic region of Pacific covering the coasts among Jalisco, Colima, Michoacan, Guerrero and Oaxaca, where this algorithm has issued 16 Public Alert and 62 Preventive Alerts to the Mexico City where its soil conditions increase damages by earthquake such as the occurred in September 1985. This work shows the review of the SAS-I algorithm and possible alerts that it could generate from major earthquakes recordings detected by FS or seismometers near the earthquakes, coming from Pacific Ocean Coast whose have been felt in Mexico

  20. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator....

  1. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway....

  2. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator....

  3. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator....

  4. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway....

  5. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway....

  6. The Traffic-Alert and Collision Avoidance System (TCAS) in the glass cockpit

    NASA Technical Reports Server (NTRS)

    Chappell, Sheryl L.

    1988-01-01

    This volume contains the contributions of the participants in the NASA Ames Research Center workshop on the traffic-alert and collision avoidance system (TCAS) implementation for aircraft with cathode ray tube (CRT) or flat panel displays. To take advantage of the display capability of the advanced-technology aircraft, NASA sponsored this workshop with the intent of bringing together industry personnel, pilots, and researchers so that pertinent issues in the area could be identified. During the 2-day workshop participants addressed a number of issues including: What is the optimum format for TCAS advisories. Where and how should maneuver advisories be presented to the crew. Should the maneuver advisories be presented on the primary flight display. Is it appropriate to have the autopilot perform the avoidance maneuver. Where and how should traffic information be presented to the crew. Should traffic information be combined with weather and navigation information. How much traffic should be shown and what ranges should be used. Contained in the document are the concepts and suggestions produced by the workshop participants.

  7. Road safety alerting system with radar and GPS cooperation in a VANET environment

    NASA Astrophysics Data System (ADS)

    Santamaria, Amilcare Francesco; Sottile, Cesare; De Rango, Floriano; Voznak, Miroslav

    2014-05-01

    New applications in wireless environments are increasing and keeping even more interests from the developer companies and researchers. In particular, in these last few years the government and institutional organization for road safety spent a lot of resources and money to promote Vehicular Ad-Hoc Network (VANET) technology, also car manufactures are giving a lot of contributions on this field as well. In our paper, we propose an innovative system to increase road safety, matching the requests of the market allowing a cooperation between on-board devices. The vehicles are equipped with On Board Unit (OBU) and On Board Radar Unit (OBRU), which can spread alerting messages around the network regarding warning and dangerous situations exploiting IEEE802.llp standard. Vehicles move along roads observing the environment, traffic and road conditions, and vehicles parameters as well. These information can be elaborated and shared between neighbors, Road Side Unit (RSU)s and, of course, with Internet, allowing inter-system communications exploiting an Road Traffic Manager (RTM). Radar systems task it the detection of the environment in order to increase the knowledge of current conditions of the roads, for example it is important to identify obstacles, road accidents, dangerous situations and so on. Once detected exploiting onboard devices, such as Global Position System (GPS) receiver it is possible to know the exact location of the caught event and after a data elaboration the information is spread along the network. Once the drivers are advised, they can make some precautionary actions such as reduction of traveling speed or modification of current road path. In this work the routing algorithms, which have the main goal to rapidly disseminate information, are also been investigated.

  8. CISN ShakeAlert: Decision Module Enhancements for Earthquake Alerts

    NASA Astrophysics Data System (ADS)

    Neuhauser, D. S.; Henson, I.; Allen, R. M.; CISN EEW Team

    2011-12-01

    The California Integrated Seismic Network (CISN) has been developing CISN ShakeAlert, a prototype end-to-end earthquake early warning system for the purpose of testing earthquake alerts with a small group of users in California. Rather than adopting a single methodology, the CISN is building a system that can accept event detections, magnitude estimates, and ground shaking predictions and observations from several systems at once. The Decision Module is the ShakeAlert component that receives earthquake detections and hazard assessments from multiple independent algorithms and methodologies, aggregates and correlates this information, and provides a single evolving view of the earthquake in progress to be delivered as an alert to people in harm's way. The alert messages generated by the Decision Module include the best or average estimate of earthquake magnitude, location, and can include predicted peak ground motion. As additional information is received from the detection algorithms, the Decision Module updates its view of the event and its assessment of the reliability of the prediction, and continues to distribute updated alert messages. The Decision Module publishes all of its alerts to a subscription-based messaging system, which allows different applications to utilize the earthquake alerts for their specific use and to make decisions based on the assessed reliability estimates from ShakeAlert. The Decision Module is designed to allow the incorporation of a Baysian approach to provide the most likely estimate of the earthquake parameters and their uncertainties. Recent enhancements to the Decision Module include processing of state-of-health packets from the multiple event detection system and the generation of state-of-health messages to allow downstream systems to assess and track the status of the earthquake alert system.

  9. A radar-based regional extreme rainfall analysis to derive the thresholds for a novel automatic alert system in Switzerland

    NASA Astrophysics Data System (ADS)

    Panziera, Luca; Gabella, Marco; Zanini, Stefano; Hering, Alessandro; Germann, Urs; Berne, Alexis

    2016-06-01

    This paper presents a regional extreme rainfall analysis based on 10 years of radar data for the 159 regions adopted for official natural hazard warnings in Switzerland. Moreover, a nowcasting tool aimed at issuing heavy precipitation regional alerts is introduced. The two topics are closely related, since the extreme rainfall analysis provides the thresholds used by the nowcasting system for the alerts. Warm and cold seasons' monthly maxima of several statistical quantities describing regional rainfall are fitted to a generalized extreme value distribution in order to derive the precipitation amounts corresponding to sub-annual return periods for durations of 1, 3, 6, 12, 24 and 48 h. It is shown that regional return levels exhibit a large spatial variability in Switzerland, and that their spatial distribution strongly depends on the duration of the aggregation period: for accumulations of 3 h and shorter, the largest return levels are found over the northerly alpine slopes, whereas for longer durations the southern Alps exhibit the largest values. The inner alpine chain shows the lowest values, in agreement with previous rainfall climatologies. The nowcasting system presented here is aimed to issue heavy rainfall alerts for a large variety of end users, who are interested in different precipitation characteristics and regions, such as, for example, small urban areas, remote alpine catchments or administrative districts. The alerts are issued not only if the rainfall measured in the immediate past or forecast in the near future exceeds some predefined thresholds but also as soon as the sum of past and forecast precipitation is larger than threshold values. This precipitation total, in fact, has primary importance in applications for which antecedent rainfall is as important as predicted one, such as urban floods early warning systems. The rainfall fields, the statistical quantity representing regional rainfall and the frequency of alerts issued in case of

  10. Technical implementation plan for the ShakeAlert production system: an Earthquake Early Warning system for the West Coast of the United States

    USGS Publications Warehouse

    Given, Douglas D.; Cochran, Elizabeth S.; Heaton, Thomas; Hauksson, Egill; Allen, Richard; Hellweg, Peggy; Vidale, John; Bodin, Paul

    2014-01-01

    Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing such an EEW system, called ShakeAlert, for the West Coast of the United States. This document describes the technical implementation of that system, which leverages existing stations and infrastructure of the Advanced National Seismic System (ANSS) regional networks to achieve this new capability. While significant progress has been made in developing the ShakeAlert early warning system, improved robustness of each component of the system and additional testing and certification are needed for the system to be reliable enough to issue public alerts. Major components of the system include dense networks of ground motion sensors, telecommunications from those sensors to central processing systems, algorithms for event detection and alert creation, and distribution systems to alert users. Capital investment costs for a West Coast EEW system are projected to be $38.3M, with additional annual maintenance and operations totaling $16.1M—in addition to current ANSS expenditures for earthquake monitoring. An EEW system is complementary to, but does not replace, other strategies to mitigate earthquake losses. The system has limitations: false and missed alerts are possible, and the area very near to an earthquake epicenter may receive little or no warning. However, such an EEW system would save lives, reduce injuries and damage, and improve community resilience by reducing longer-term economic losses for both public and private entities.

  11. Developing Network Situational Awareness through Visualizations of Fused Intrusion Detection System Alerts

    DTIC Science & Technology

    2008-06-01

    Phishing with Plug and Play Exploit. In this attack, the at- tacker sets up a website offering the visitor free “ porn ” if they sign up. The user is allowed... porn alert so its unclear at the moment if 100.20.3.127 is compromised and if so, how it is compromised because there are no other alerts at this time...unauthorized porn website. The investigation would conclude that the attacker at 51.251.22.183 used the information gained from the website to open an

  12. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator....

  13. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway....

  14. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway....

  15. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator....

  16. Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates.

    PubMed

    McDonald, C P; Rogers, A; Cox, M; Smith, R; Roy, A; Robbins, S; Hartley, S; Barbara, J A J; Rothenberg, S; Stutzman, L; Widders, G

    2002-10-01

    Bacterial transmission remains the major component of morbidity and mortality associated with transfusion-transmitted infections. Platelet concentrates are the most common cause of bacterial transmission. The BacT/ALERT 3D automated blood culture system has the potential to screen platelet concentrates for the presence of bacteria. Evaluation of this system was performed by spiking day 2 apheresis platelet units with individual bacterial isolates at final concentrations of 10 and 100 colony-forming units (cfu) mL-1. Fifteen organisms were used which had been cited in platelet transmission and monitoring studies. BacT/ALERT times to detection were compared with thioglycollate broth cultures, and the performance of five types of BacT/ALERT culture bottles was evaluated. Sampling was performed immediately after the inoculation of the units, and 10 replicates were performed per organism concentration for each of the five types of BacT/ALERT bottles. The mean times for the detection of these 15 organisms by BacT/ALERT, with the exception of Propionibacterium acnes, ranged from 9.1 to 48.1 h (all 10 replicates were positive). In comparison, the time range found using thioglycollate was 12.0-32.3 h (all 10 replicates were positive). P. acnes' BacT/ALERT mean detection times ranged from 89.0 to 177.6 h compared with 75.6-86.4 h for the thioglycollate broth. BacT/ALERT, with the exception of P. acnes, which has dubious clinical significance, gave equivalent or shorter detection times when compared with the thioglycollate broth system. The BacT/ALERT system detected a range of organisms at levels of 10 and 100 cfu mL-1. This study validates the BacT/ALERT microbial detection system for screening platelets. Currently, the system is the only practically viable option available for routinely screening platelet concentrates to prevent bacterial transmission.

  17. Development of an Academic Alert and Advisement System Using a Participational Governance Structure.

    ERIC Educational Resources Information Center

    Mackin, Sara Lee

    Due to the implementation of new standards for academic progress in Fall 1978 and the resultant suspension of or imposition of credit limitations upon students not meeting these standards, Miami-Dade Community College developed and tested an academic alert program in which computer-generated letters were sent to students at mid-term to provide an…

  18. Response Times in Correcting Non-Normal System Events When Collocating Status, Alerts and Procedures, and Controls

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    2002-01-01

    Currently, most of the displays in control rooms can be categorized as status, alerts/procedures, or control screens. With the advent and use of CRTs and the associated computing power available to compute and display information, it is now possible to combine these different elements of information and control onto a single display. An experiment was conducted to determine which, if any, of these functions should be collocated in order to better handle simple anticipated non-normal system events. The results indicated that there are performance benefits and subject preferences to combining all the information onto one screen or combining the status and alert/procedure information onto one screen and placing the controls in another area.

  19. Development of a Human Motor Model for the Evaluation of an Integrated Alerting and Notification Flight Deck System

    NASA Technical Reports Server (NTRS)

    Daiker, Ron; Schnell, Thomas

    2010-01-01

    A human motor model was developed on the basis of performance data that was collected in a flight simulator. The motor model is under consideration as one component of a virtual pilot model for the evaluation of NextGen crew alerting and notification systems in flight decks. This model may be used in a digital Monte Carlo simulation to compare flight deck layout design alternatives. The virtual pilot model is being developed as part of a NASA project to evaluate multiple crews alerting and notification flight deck configurations. Model parameters were derived from empirical distributions of pilot data collected in a flight simulator experiment. The goal of this model is to simulate pilot motor performance in the approach-to-landing task. The unique challenges associated with modeling the complex dynamics of humans interacting with the cockpit environment are discussed, along with the current state and future direction of the model.

  20. Use of Circadian Lighting System to improve night shift alertness and performance of NRC Headquarters Operations Officers

    SciTech Connect

    Baker, T.L.; Morisseau, D.; Murphy, N.M.

    1995-04-01

    The Nuclear Regulatory Commission`s (NRC) Headquarters Operations Officers (HOOs) receive and respond to events reported in the nuclear industry on a 24-hour basis. The HOOs have reported reduced alertness on the night shift, leading to a potential deterioration in their on-shift cognitive performance during the early morning hours. For some HOOs, maladaptation to the night shift was also reported to be the principal cause of: (a) reduced alertness during the commute to and from work, (b) poor sleep quality, and (c) personal lifestyle problems. ShiftWork Systems, Inc. (SWS) designed and installed a Circadian Lighting System (CLS) at both the Bethesda and Rockville HOO stations with the goal of facilitating the HOOs physiological adjustment to their night shift schedules. The data indicate the following findings: less subjective fatigue on night shifts; improved night shift alertness and mental performance; higher HOO confidence in their ability to assess event reports; longer, deeper and more restorative day sleep after night duty shifts; swifter adaptation to night work; and a safer commute, particularly for those with extensive drives.

  1. Wireless Emergency Alerts

    MedlinePlus

    ... Us Main Content Frequently Asked Questions: Wireless Emergency Alerts This section contains answers to a list of frequently asked questions about Wireless Emergency Alerts (WEAs). Why are Wireless Emergency Alerts (WEA) important ...

  2. Technology, work, and information flows: lessons from the implementation of a wireless alert pager system.

    PubMed

    Reddy, Madhu C; McDonald, David W; Pratt, Wanda; Shabot, M Michael

    2005-06-01

    The combination of collaborative work practices and information technology affect the flow of information in clinical settings. The introduction of a new technology into these settings can change not only established work practices but also the information flows. In this paper, we examine the introduction of a wireless alerts pager in a surgical intensive care unit (SICU). Through a qualitative study, we analyze the effects that this new information tool had on both the work practices in the SICU and the information flow in the unit. We describe four challenges that SICU staff members faced with respect to the alerts pagers. We found that the pager provided new routes of information to SICU staff but in doing so disrupted existing work practices and information flows.

  3. Influencing Anesthesia Provider Behavior Using Anesthesia Information Management System Data for Near Real-Time Alerts and Post Hoc Reports.

    PubMed

    Epstein, Richard H; Dexter, Franklin; Patel, Neil

    2015-09-01

    In this review article, we address issues related to using data from anesthesia information management systems (AIMS) to deliver near real-time alerts via AIMS workstation popups and/or alphanumeric pagers and post hoc reports via e-mail. We focus on reports and alerts for influencing the behavior of anesthesia providers (i.e., anesthesiologists, anesthesia residents, and nurse anesthetists). Multiple studies have shown that anesthesia clinical decision support (CDS) improves adherence to protocols and increases financial performance through facilitation of billing, regulatory, and compliance documentation; however, improved clinical outcomes have not been demonstrated. We inform developers and users of feedback systems about the multitude of concerns to consider during development and implementation of CDS to increase its effectiveness and to mitigate its potentially disruptive aspects. We discuss the timing and modalities used to deliver messages, implications of outlier-only versus individualized feedback, the need to consider possible unintended consequences of such feedback, regulations, sustainability, and portability among systems. We discuss statistical issues related to the appropriate evaluation of CDS efficacy. We provide a systematic review of the published literature (indexed in PubMed) of anesthesia CDS and offer 2 case studies of CDS interventions using AIMS data from our own institution illustrating the salient points. Because of the considerable expense and complexity of maintaining near real-time CDS systems, as compared with providing individual reports via e-mail after the fact, we suggest that if the same goal can be accomplished via delayed reporting versus immediate feedback, the former approach is preferable. Nevertheless, some processes require near real-time alerts to produce the desired improvement. Post hoc e-mail reporting from enterprise-wide electronic health record systems is straightforward and can be accomplished using system

  4. Global Environmental Alert Service

    NASA Astrophysics Data System (ADS)

    Singh, A.; Grasso, V. F.

    There is a pressing need to build a mechanism which can consolidate scientific information and evidences package this knowledge in a form usable to international and national decision makers and actively disseminate this information to those users Although much information and many data sets are available in the public domain currently there is no information broker who searches and packages the policy relevant material and delivers that information in an easily understandable format to the public and decision makers A Global Environmental Alert Service GEAS could provide information emanating from monitoring earth observing and early warning systems to users in a near real time mode and bridge the gap between the scientific community and policy makers A state-of-art analysis of existing alert systems indicates that efforts are necessary for turning the tide in early warning processes and technologies A comparison analysis of existing warning systems is presented in order to assess feasibility and performance of existing systems of interest Several criteria have been chosen for the comparison analysis so as to provide a comprehensive description of the systems regarding coverage of contents impact and accessibility to information A critical review of existing alert systems reveals a major gap and need for an innovative service Characteristics and operational aspects of such a service are proposed Early warning represents the process to effectively and timely detect a potential risk

  5. Photovoltaic Systems for Government Agencies

    DTIC Science & Technology

    1994-02-01

    i -- • • ;__ S• .... S,<, - Loca ted in the Adirondacks this photovoltaic system powers a facility offering visitors a clean, odorless, and...current depends on type of metal, composition of the soil, salinity of water, and surface area of metal to be protected. Historically, cathodic

  6. Flight tests of a clear-air turbulence alerting system. [infrared radiometers

    NASA Technical Reports Server (NTRS)

    Kurkowski, R. L.; Kuhn, P. M.; Stearns, L. P.

    1981-01-01

    The detection of clear-air turbulence (CAT) ahead of an aircraft in real-time by an infrared (IR) radiometer is discussed. It is noted that the alter time and reliability depend on the band-pass of the IR filter used and on the altitude of the aircraft. Results of flights tests indicate that a bandpass of 20 to 40 microns appears optimal for altering the aircraft crew to CAT at times before encounter of 2 to 9 min. Alert time increases with altitude, as the atmospheric absorption determining the horizontal weighting is reduced.

  7. 78 FR 19271 - Special Fraud Alert: Physician-Owned Entities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-29

    ... HUMAN SERVICES Office of Inspector General Special Fraud Alert: Physician-Owned Entities AGENCY: Office of Inspector General (OIG), HHS. ACTION: Notice. SUMMARY: This Special Fraud Alert addresses.... Introduction This Special Fraud Alert addresses physician-owned entities that derive revenue from selling,...

  8. INTEGRAL burst alert service

    NASA Technical Reports Server (NTRS)

    Pedersen, H.; Jennings, D.; Mereghetti, S.; Teegarden, B.

    1997-01-01

    The detection, accurate positioning, and spectral analysis of cosmic gamma ray bursts is an objective of the International Gamma Ray Astrophysics Laboratory (INTEGRAL) mission. Due to their unpredictable nature, gamma ray bursts can only be observed in serendipity mode. In order to allow and promote multiwavelength follow-up observations of such events, it is desirable to make the information available to the astrophysics community with a minimum delay through the use of Internet. Ideally, the data dissemination should occur within a few seconds of the start of the burst event so that follow up observations can proceed while gamma rays are still being emitted. The technical feasibility of building such a system to disseminate INTEGRAL burst alerts in real time is currently under consideration, the preliminary results of which are presented. It is concluded that such an alert service is technically feasible.

  9. Assessment of the need for dual indoor/outdoor warning systems and enhanced tone alert technologies in the Chemical Stockpile Emergency Preparedness Program

    SciTech Connect

    Sorensen, J.H.

    1992-05-01

    The need for a dual indoor/outdoor warning system as recommended by the program guidance and Alert and Notification (A&N) standard for the Chemical Stockpile Emergency Preparedness Program is analyzed in this report. Under the current program standards, the outdoor warning system consists of omnidirectional sirens and the new indoor system would be an enhanced tone alert (TA) radio system. This analysis identifies various tone-alert technologies, distribution options, and alternative siren configurations. It also assesses the costs and benefits of the options and analyzes what appears to best meet program needs. Given the current evidence, it is recommended that a 10-dB siren system and the special or enhanced TA radio be distributed to each residence and special institution in the immediate response zone as preferred the A&N standard. This approach minimizes the cost of maintenance and cost of the TA radio system while providing a high degree of reliability for indoor alerting. Furthermore, it reaches the population (residential and institutional) in the greatest need of indoor alerting.

  10. Assessment of the need for dual indoor/outdoor warning systems and enhanced tone alert technologies in the Chemical Stockpile Emergency Preparedness Program

    SciTech Connect

    Sorensen, J.H.

    1992-05-01

    The need for a dual indoor/outdoor warning system as recommended by the program guidance and Alert and Notification (A N) standard for the Chemical Stockpile Emergency Preparedness Program is analyzed in this report. Under the current program standards, the outdoor warning system consists of omnidirectional sirens and the new indoor system would be an enhanced tone alert (TA) radio system. This analysis identifies various tone-alert technologies, distribution options, and alternative siren configurations. It also assesses the costs and benefits of the options and analyzes what appears to best meet program needs. Given the current evidence, it is recommended that a 10-dB siren system and the special or enhanced TA radio be distributed to each residence and special institution in the immediate response zone as preferred the A N standard. This approach minimizes the cost of maintenance and cost of the TA radio system while providing a high degree of reliability for indoor alerting. Furthermore, it reaches the population (residential and institutional) in the greatest need of indoor alerting.

  11. Distribution of rest days in 12 hour shift systems: impacts on health, wellbeing, and on shift alertness

    PubMed Central

    Tucker, P.; Smith, L.; Macdonald, I.; Folkard, S.

    1999-01-01

    OBJECTIVES: To investigate of the effects of distribution of rest days in 12 hour shift systems. Although several studies have examined the effects of compressing work schedules by comparing 8 and 12 hour shift systems, there is little published research examining the various forms of 12 hour shift system. METHODS: An abridged version of the standard shiftwork index which included retrospective alertness ratings was completed by a large sample of industrial shiftworkers. The respondents worked 12 hour shift systems that either did or did not incorporate breaks of > 24 hours between the blocks of day and night shifts. For the purposes of the analysis, each of these two groups were further subdivided into those who started their morning shift at 0600 and those who started at 0700. RESULTS: Systems which incorporated rest days between the day and night shifts were associated with slightly higher levels of on shift alertness, slightly lower levels of chronic fatigue, along with longer sleep durations when working night shifts and between rest days. Early changeovers were associated with shorter night sleeps between successive day shifts, but longer and less disturbed day sleeps between night shifts. These effects of changeover time were broadly in agreement with previous research findings. CONCLUSIONS: The distribution of rest days in 12 hour shift systems had only limited effects on the outcome measures, although the few modest differences that were found favoured systems which incorporated rest days between the day and night shifts. It is conceded that the design of the study may have obscured some subtle differences between the shift systems. Nevertheless, it is concluded that the impact of distribution of rest days seems to be minor relative to previously found effects of other features of shift systems--for example, shift duration.   PMID:10448331

  12. Improving the health forecasting alert system for cold weather and heat-waves in England: a case-study approach using temperature-mortality relationships

    NASA Astrophysics Data System (ADS)

    Masato, Giacomo; Cavany, Sean; Charlton-Perez, Andrew; Dacre, Helen; Bone, Angie; Carmicheal, Katie; Murray, Virginia; Danker, Rutger; Neal, Rob; Sarran, Christophe

    2015-04-01

    The health forecasting alert system for cold weather and heatwaves currently in use in the Cold Weather and Heatwave plans for England is based on 5 alert levels, with levels 2 and 3 dependent on a forecast or actual single temperature action trigger. Epidemiological evidence indicates that for both heat and cold, the impact on human health is gradual, with worsening impact for more extreme temperatures. The 60% risk of heat and cold forecasts used by the alerts is a rather crude probabilistic measure, which could be substantially improved thanks to the state-of-the-art forecast techniques. In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater

  13. Integration of heterogeneous clinical decision support systems and their knowledge sets: feasibility study with Drug-Drug Interaction alerts.

    PubMed

    Kam, Hye Jin; Kim, Jeong Ah; Cho, InSook; Kim, Yoon; Park, Rae Woong

    2011-01-01

    There exist limitations in both commercial and in-house clinical decision support systems (CDSSs) and issues related to the integration of different knowledge sources and CDSSs. We chose Standard-based Shareable Active Guideline Environment (SAGE) as a new architecture with knowledge integration and a centralized knowledge base which includes authoring/management functions and independent CDSS, and applied it to Drug-Drug Interaction (DDI) CDSS. The aim of this study was to evaluate the feasibility of the newly integrated DDI alerting CDSS into a real world hospital information system involving construction of an integrated CDSS derived from two heterogeneous systems and their knowledge sets. The proposed CDSS was successfully implemented and compensated for the weaknesses of the old CDSS from knowledge integration and management, and its applicability in actual situations was verified. Although the DDI CDSS was constructed as an example case, the new CDS architecture might prove applicable to areas of CDSSs.

  14. Project ALERT: Three Years Of A Catalytic Partnership For Improving Pre-Service Teacher Education In Earth System Sciences

    NASA Astrophysics Data System (ADS)

    Ambos, E. L.; Ng, E. W.; Metzger, E. P.; Skiles, J. W.; Simila, G.; Garfield, N.

    2001-12-01

    During the last three years, a California-based partnership for improving earth science education and outreach has grown between ten California State University (CSU) campuses, and two NASA centers in California, Ames Research Center (ARC), and the Jet Propulsion Laboratory (JPL). This partnership, Project ALERT (Augmented Learning Environment and Renewable Teaching) has had as its main goal the improvement of earth system science education for pre-service teachers, with particular focus on urban northern and southern California regions. Objectives associated with this goal have included evaluating and using existing NASA earth system science educational materials, creating new materials as needed, and linking CSU earth science and science education professors with NASA earth scientists and outreach and technology specialists through cooperative research and education projects. Strategies to develop the regional partnership include providing summer faculty fellowships at JPL and ARC for CSU professors and NASA scientists and outreach and education specialists, with supplementary funding for CSU professors and workshops involving CSU and NASA center personnel during the academic year. Highlights of the last three years of ALERT include: (1) the formation of new, "spin-off" projects that address curriculum reform and in-service teacher education in the earth system sciences, or digital library issues, (2) creation of a shared web site and resources for university-level introductory earth system science instruction (http://projectalert.nasa.gov), (3) evaluation and, in some instances, improvement of existing NASA-generated instructional materials, (4) intensified interest on the part of CSU faculty in education issues, leading to policy roles on respective CSU campuses, (5) modification and/or creation of more than six courses specifically incorporating earth system science into pre-service teacher education, and, (6) heightened awareness of educational and digital

  15. Design and implementation of a structural health monitoring and alerting system for hospital buildings in the United States

    USGS Publications Warehouse

    Ulusoy, Hasan S.; Kalkan, Erol; Fletcher, Jon Peter B.; Friberg, Paul; Leith, W. K.; Banga, Krishna

    2012-01-01

    This paper describes the current progress in the development of a structural health monitoring and alerting system to meet the needs of the U.S. Department of Veterans Affairs to monitor hospital buildings instrumented in high and very high seismic hazard regions in the U.S. The system, using the measured vibration data, is primarily designed for post-earthquake condition assessment of the buildings. It has two essential components – sensing and analysis. The sensing component includes all necessary firmware and sensors to measure the response of the building; while the analysis component consists of several data processing modules integrated into an open source software package which compresses a large amount of measured data into useful information to assess the building’s condition before and after an event. The information can be used for a rapid building safety assessment, and to support decisions for necessary repairs, replacements, and other maintenance and rehabilitation measures.

  16. Self-activating System and Method for Alerting When an Object or a Person is Left Unattended

    NASA Technical Reports Server (NTRS)

    Edwards, William C. (Inventor); Mack, Terry L. (Inventor); Modlin, Edward A. (Inventor)

    2006-01-01

    A system and method use a wireless tether comprising a transmitter and a receiver to alert a caregiver that an object has been left unattended. A detector senses the presence of the object, usually a child, located in a position such as a safety seat. The detector is operatively coupled to the transmitter. which is located near the object. The transmitter transmits at least one wireless signal when the object is in the position. The receiver, which is remotely located from the transmitter, senses at least one signal as long as the receiver is within a prescribed range of transmission. By performing a timing function, the receiver monitors the proximity of the caregiver, who maintains possession of the receiver, to the transmitter. The system communicates an alarm to the caregiver when the caregiver ventures outside the range of transmission without having removed the object from the position.

  17. Medical alert bracelet (image)

    MedlinePlus

    People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will ... People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will ...

  18. Alert Triage v 0.1 beta

    SciTech Connect

    Doak, Justin E.; Ingram, Joe; Johnson, Josh; Franklin, Dustin; Shelfburg, Jeff

    2016-01-06

    In the cyber security operations of a typical organization, data from multiple sources are monitored, and when certain conditions in the data are met, an alert is generated in an alert management system. Analysts inspect these alerts to decide if any deserve promotion to an event requiring further scrutiny. This triage process is manual, time-consuming, and detracts from the in-depth investigation of events. We have created a software system that uses supervised machine learning to automatically prioritize these alerts. In particular we utilize active learning to make efficient use of the pool of unlabeled alerts, thereby improving the performance of our ranking models over passive learning. We have demonstrated the effectiveness of our system on a large, real-world dataset of cyber security alerts.

  19. CISN ShakeAlert: The Decision Module for Earthquake Alerts

    NASA Astrophysics Data System (ADS)

    Neuhauser, D. S.; Khainovsky, O.; Böse, M.; Solanki, K.; Cua, G. B.; Heaton, T. H.; Allen, R. M.; Cisn Earthquake Early Warning Team

    2010-12-01

    The CISN is currently in the process of developing and implementing CISN ShakeAlert, a prototype end-to-end earthquake early warning system for the purpose of testing earthquake alerts with a small group of users. The Decision Module is the component of this system that takes earthquake detections and hazard assessments from several independent systems, and provides a single view of the earthquake in progress that can be forwarded as an alert to people in harm's way. Over the last few years, several methodologies for earthquake alerts have been tested by the CISN group in California and yet more methodologies are now being tested around the world. A variety of approaches to earthquake early warning have proven to work. Rather than adopting a single methodology, the CISN is building a system that can accept event detections, magnitude estimates, and ground shaking predictions from several systems at once. The Decision Module reconciles and integrates the event information coming from the various systems and provides a unified view of the earthquakes in progress, generating alert messages when appropriate. Initially, the Decision Module will be very basic, providing the capability of identifying earthquake detections from different systems as the same event, and distributing the best or average estimate of earthquake magnitude, location, ground shaking intensity, etc. However, the system is being designed to allow the incorporation of a Baysian approach to provide the most likely estimate of the earthquake parameters and their uncertainties. The Decision Module publishes its results to a subscription-based messaging system to allow different applications to utilize the earthquake alerts for their specific use.

  20. Agency in natural and artificial systems.

    PubMed

    Moreno, Alvaro; Etxeberria, Arantza

    2005-01-01

    We analyze the conditions for agency in natural and artificial systems. In the case of basic (natural) autonomous systems, self-construction and activity in the environment are two aspects of the same organization, the distinction between which is entirely conceptual: their sensorimotor activities are metabolic, realized according to the same principles and through the same material transformations as those typical of internal processes (such as energy transduction). The two aspects begin to be distinguishable in a particular evolutionary trend, related to the size increase of some groups of organisms whose adaptive abilities depend on motility. Here a specialized system develops, which, in the sensorimotor aspect, is decoupled from the metabolic basis, although it remains dependent on it in the self-constructive aspect. This decoupling reveals a complexification of the organization. In the last section of the article this approach to natural agency is used to analyze artificial systems by posing two problems: whether it is possible to artificially build an organization similar to the natural, and whether this notion of agency can be grounded on different organizing principles.

  1. Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease - Guinea, 2014-2015.

    PubMed

    Lee, Christopher T; Bulterys, Marc; Martel, Lise D; Dahl, Benjamin A

    2016-03-11

    The epidemic of Ebola virus disease (Ebola) in West Africa began in Guinea in late 2013 (1), and on August 8, 2014, the World Health Organization (WHO) declared the epidemic a Public Health Emergency of International Concern (2). Guinea was declared Ebola-free on December 29, 2015, and is under a 90 day period of enhanced surveillance, following 3,351 confirmed and 453 probable cases of Ebola and 2,536 deaths (3). Passive surveillance for Ebola in Guinea has been conducted principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert numbers operated by prefecture health departments or to a national toll-free call center. The national call center additionally functions as a source of public health information by responding to questions from the public about Ebola. To evaluate the sensitivity of the two systems and compare the sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined prefecture alerts database, as well as the national call center database, with the national viral hemorrhagic fever (VHF) database; the VHF database contains records of all known confirmed Ebola cases. Among 17,309 alert calls analyzed from the national call center, 71 were linked to 1,838 confirmed Ebola cases in the VHF database, yielding a sensitivity of 3.9%. The sensitivity of the national call center was highest in the capital city of Conakry (11.4%) and lower in other prefectures. In comparison, the local alerts system had a sensitivity of 51.1%. Local public health infrastructure plays an important role in surveillance in an epidemic setting.

  2. Traffic Alert and Collision Avoidance System (TCAS): Cockpit Display of Traffic Information (CDTI) investigation. Phase 1: Feasibility study

    NASA Technical Reports Server (NTRS)

    Burgess, Malcolm; Davis, Dean; Hollister, Walter; Sorensen, John A.

    1991-01-01

    The possibility of the Threat Alert and Collision Avoidance System (TCAS) traffic sensor and display being used for meaningful Cockpit Display of Traffic Information (CDTI) applications has resulted in the Federal Aviation Administration initiating a project to establish the technical and operational requirements to realize this potential. Phase 1 of the project is presented here. Phase 1 was organized to define specific CDTI applications for the terminal area, to determine what has already been learned about CDTI technology relevant to these applications, and to define the engineering required to supply the remaining TCAS-CDTI technology for capacity benefit realization. The CDTI applications examined have been limited to those appropriate to the final approach and departure phases of flight.

  3. Integration of Airborne Aerosol Prediction Systems and Vegetation Phenology to Track Pollen for Asthma Alerts in Public Health Decision Support Systems

    NASA Technical Reports Server (NTRS)

    Luvall, Jeffrey C.; Sprigg, William A.; Huete, Alfredo; Pejanovic, Goran; Nickovic,Slobodan; Ponce-Campos, Guillermo; Krapfl, Heide; Budge, Amy; Zelicoff, Alan; VandeWater, Peter K.; Levetin, Estelle; Crimmins, Theresa; Weltzin, Jake

    2011-01-01

    This slide presentation reviews the study that used a model to forecast pollen to assist in warning for asthma populations. Using MODIS daily reflectances to input to a model, PREAM, adapted from the Dust REgional Atmospheric Modeling (DREAM) system, a product of predicted pollen is produced. Using the pollen from Juniper the PREAM model was shown to be an assist in alerting the public of pollen bursts, and reduce the health impact on asthma populations.

  4. The Common Alerting Protocol (CAP) and Emergency Data Exchange Language (EDXL) - Application in Early Warning Systems for Natural Hazard

    NASA Astrophysics Data System (ADS)

    Lendholt, Matthias; Hammitzsch, Martin; Wächter, Joachim

    2010-05-01

    The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In conjunction with the Emergency Data Exchange Language (EDXL) Distribution Element (-DE) [2] these data formats can be used for warning message dissemination in early warning systems for natural hazards. Application took place in the DEWS (Distance Early Warning System) [3] project where CAP serves as central message format containing both human readable warnings and structured data for automatic processing by message receivers. In particular the spatial reference capabilities are of paramount importance both in CAP and EDXL. Affected areas are addressable via geo codes like HASC (Hierarchical Administrative Subdivision Codes) [4] or UN/LOCODE [5] but also with arbitrary polygons that can be directly generated out of GML [6]. For each affected area standardized criticality values (urgency, severity and certainty) have to be set but also application specific key-value-pairs like estimated time of arrival or maximum inundation height can be specified. This enables - together with multilingualism, message aggregation and message conversion for different dissemination channels - the generation of user-specific tailored warning messages. [1] CAP, http://www.oasis-emergency.org/cap [2] EDXL-DE, http://docs.oasis-open.org/emergency/edxl-de/v1.0/EDXL-DE_Spec_v1.0.pdf [3] DEWS, http://www.dews-online.org [4] HASC, "Administrative Subdivisions of Countries: A Comprehensive World Reference, 1900 Through 1998" ISBN 0-7864-0729-8 [5] UN/LOCODE, http://www.unece.org/cefact/codesfortrade/codes_index.htm [6] GML, http://www.opengeospatial.org/standards/gml

  5. Real-time earthquake alert system for the greater San Francisco Bay Area: a prototype design to address operational issues

    SciTech Connect

    Harben, P.E.; Jarpe, S.; Hunter, S.

    1996-12-10

    The purpose of the earthquake alert system (EAS) is to outrun the seismic energy released in a large earthquake using a geographically distributed network of strong motion sensors that telemeter data to a rapid CPU-processing station, which then issues an area-wide warning to a region before strong motion will occur. The warning times involved are short, from 0 to 30 seconds or so; consequently, most responses must be automated. The San Francisco Bay Area is particularly well suited for an EAS because (1) large earthquakes have relatively shallow hypocenters (10- to 20-kilometer depth), giving favorable ray-path geometries for larger warning times than deeper from earthquakes, and (2) the active faults are few in number and well characterized, which means far fewer geographically distributed strong motion sensors are (about 50 in this region). An EAS prototype is being implemented in the San Francisco Bay Area. The system consists of four distinct subsystems: (1) a distributed strong motion seismic network, (2) a central processing station, (3) a warning communications system and (4) user receiver and response systems. We have designed a simple, reliable, and inexpensive strong motion monitoring station that consists of a three-component Analog Devices ADXLO5 accelerometer sensing unit, a vertical component weak motion sensor for system testing, a 16-bit digitizer with multiplexing, and communication output ports for RS232 modem or radio telemetry. The unit is battery-powered and will be sited in fire stations. The prototype central computer analysis system consists of a PC dam-acquisition platform that pipes the incoming strong motion data via Ethernet to Unix-based workstations for dam processing. Simple real-time algorithms, particularly for magnitude estimation, are implemented to give estimates of the time since the earthquake`s onset its hypocenter location, its magnitude, and the reliability of the estimate. These parameters are calculated and transmitted

  6. Human factors considerations for contraindication alerts.

    PubMed

    van der Sijs, Heleen; Baboe, Imtiaaz; Phansalkar, Shobha

    2013-01-01

    Alert fatigue is a ubiquitous problem in clinical decision support systems. Several remedies to alert fatigue have been proposed including improving the specificity of alerts and compliance with human factors principles. Human factors principles that are relevant for drug safety alerting have been identified and operationalized for drug-drug interactions (DDIs), resulting in a previously developed and validated quantitative instrument. Such an instrument is lacking for contraindications. This study describes the operationalization of human factors principles for contraindication alerting. Thirty items associated with 10 human factors principles are included in the instrument: 4 items are new, 5 are similar, and 21 are equal to the DDI-instrument. The instrument was further operationalized to a test protocol. Three independent persons used the test protocol. Inter-rater reliability indicated moderate agreement (κ=0.540) It is feasible to test the implementation of human factors in contraindication alert design with the newly developed instrument.

  7. Alert Override Reasons: A Failure to Communicate

    PubMed Central

    Chused, Amy E.; Kuperman, Gilad J.; Stetson, Peter D.

    2008-01-01

    In 2007, the Leapfrog CPOE standard required that all clinical alert overrides be accompanied by an override reason. We wanted to know how many of the free text comments left by clinicians were actually override reasons, and how many were other types of communication. We reviewed 3583 free text comments left voluntarily by clinicians while responding to an alert in a CPOE system. Of the comments received, 58% were override reasons, 28% were acknowledgement of the alert, 9% were content free and over 5% were misdirected communication, written with intent to reach someone who did not receive the alert comments. This is particularly concerning because much of the misdirected communication contained clinical instructions. Those clinical instructions were stored with the alert rather than with any clinical orders, and thus were not viewed by anyone receiving the orders. Our results show that free text alert comments may cause communication failures. PMID:18999082

  8. Marine Animal Alert System -- Task 2.1.5.3: Development of Monitoring Technologies -- FY 2011 Progress Report

    SciTech Connect

    Carlson, Thomas J.; Deng, Zhiqun; Myers, Joshua R.; Matzner, Shari; Copping, Andrea E.

    2011-09-30

    The Marine Animal Alert System (MAAS) in development by the Pacific Northwest National Laboratory is focused on providing elements of compliance monitoring to support deployment of marine hydrokinetic energy devices. An initial focus is prototype tidal turbines to be deployed in Puget Sound in Washington State. The MAAS will help manage the risk of injury or mortality to marine animals from blade strike or contact with tidal turbines. In particular, development has focused on detection, classification, and localization of listed Southern Resident killer whales within 200 m of prototype turbines using both active and passive acoustic approaches. At the close of FY 2011, a passive acoustic system consisting of a pair of four-element star arrays and parallel processing of eight channels of acoustic receptions has been designed and built. Field tests of the prototype system are scheduled for the fourth quarter of calendar year 2011. Field deployment and testing of the passive acoustic prototype is scheduled for the first quarter of FY 2012. The design of an active acoustic system that could be built using commercially available off-the-shelf components from active acoustic system vendors is also in the final stages of design and specification.

  9. 75 FR 67201 - Flightcrew Alerting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-02

    ... that section, the FAA is charged with promoting safe flight of civil aircraft in air commerce by... Alert and Collision Avoidance Systems Aircraft Flight Information Services-Broadcast (FIS-B) Data Link.../17/2002. TSO-C157, Aircraft Flight Information Services-Broadcast (FIS-B) Data Link Systems...

  10. 75 FR 81512 - Airworthiness Directives; Various Aviation Communication & Surveillance Systems (ACSS) Traffic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-28

    ... Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) Units AGENCY... received reports of anomalies with the Aviation Communication & Surveillance Systems (ACSS) Traffic Alert...) Traffic Alert and Collision Avoidance System (TCAS) units with the part numbers (P/Ns) specified in...

  11. Evaluation of a Novel Kit for Use with the BacT/ALERT 3D System for Drug Susceptibility Testing of Mycobacterium tuberculosis

    PubMed Central

    Werngren, Jim; Klintz, Lisbeth; Hoffner, Sven E.

    2006-01-01

    We evaluated a new protocol for the BacT/ALERT MB susceptibility test (bioMérieux Inc., Durham, NC) using 80 Mycobacterium tuberculosis WHO challenge panel strains. The drug susceptibility profiles of these strains are well characterized, and consensus drug resistance results have been established after tests were performed at around 20 international reference laboratories using recommended reference drug susceptibility techniques. Strains were tested according to the bioMérieux protocol using the following critical concentrations: rifampin (RIF), 0.9 mg/liter; isoniazid (INH), 0.4 and 0.09 mg/liter; and ethambutol (EMB), 1.8 mg/liter. The BacT/ALERT system detected 36/37 RIF-resistant strains. For INH (low concentration), 59/59 resistant strains were detected, and for EMB, 34/34 resistant strains were detected. Thus, the sensitivities were 97%, 100%, and 100% for RIF, INH, and EMB, respectively. The corresponding specificities were 100%, 95%, and 98%, respectively, for the same drugs. As soon as the BacT/ALERT MP seed bottle flagged positive, the median time to obtain a susceptibility results was 7.8 days. The results show good concordance with the consensus results of the international reference laboratories and demonstrate that BacT/ALERT 3D should be considered as an alternative method for rapid and automated drug susceptibility testing of M. tuberculosis. PMID:16757609

  12. Comparative Evaluation of Löwenstein-Jensen Proportion Method, BacT/ALERT 3D System, and Enzymatic Pyrazinamidase Assay for Pyrazinamide Susceptibility Testing of Mycobacterium tuberculosis▿

    PubMed Central

    Singh, Pushpendra; Wesley, Clement; Jadaun, G. P. S.; Malonia, Sunil Kumar; Das, R.; Upadhyay, P.; Faujdar, J.; Sharma, P.; Gupta, P.; Mishra, Abhay Kumar; Singh, Kalpana; Chauhan, D. S.; Sharma, V. D.; Gupta, U. D.; Venkatesan, K.; Katoch, V. M.

    2007-01-01

    Pyrazinamide (PZA) is an important first-line antituberculosis drug because of its sterilizing activity against semidormant tubercle bacilli. In spite of its very high in vivo activity, its in vitro activity is not apparent unless an acidic environment is available, which makes PZA susceptibility testing difficult by conventional methods. The present study was, therefore, planned to assess the performance of the colorimetric BacT/ALERT 3D system and compare the results with those from conventional tests, i.e., the Löwenstein-Jensen (LJ) proportion method (pH 4.85) and Wayne's pyrazinamidase (PZase) assay, using 107 clinical isolates. The concordance among all of these tests was 89.71% after the first round of testing and reached 92.52% after resolution of the discordant results by retesting. Prolonged incubation of the PZase tube for up to 10 days was found to increase the specificity of the PZase test. The concordances between LJ proportion and BacT/ALERT 3D, LJ proportion and the PZase assay, and BacT/ALERT 3D and the PZase assay were found to be 99.06%, 93.46%, and 92.52%, respectively. Using the LJ results as the gold standard, the sensitivities of BacT/ALERT 3D and the PZase assay were 100 and 82.85%, respectively, while the specificity was 98.61% for both of the tests. The difference between the sensitivities of BacT/ALERT 3D and the PZase assay was significant (P = 0.025). The mean turnaround times for the detection of resistant and susceptible results by BacT/ALERT 3D were 8.04 and 11.32 days, respectively. While the major limitations associated with the PZase assay and the LJ proportion method are lower sensitivity in previously treated patients and a longer time requirement, respectively, the BacT/ALERT 3D system was found to be rapid, highly sensitive, and specific. PMID:17093022

  13. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions... protocols between the Federal alert gateway and the CMS provider gateway. (d) Geographic targeting. The...

  14. Effectiveness of a Mobile Short-Message-Service–Based Disease Outbreak Alert System in Kenya

    PubMed Central

    Njeru, Ian; Zurovac, Dejan; Tipo, Shikanga O; Kareko, David; Mwau, Matilu; Morita, Kouichi

    2016-01-01

    We conducted a randomized, controlled trial to test the effectiveness of a text-messaging system used for notification of disease outbreaks in Kenya. Health facilities that used the system had more timely notifications than those that did not (19.2% vs. 2.6%), indicating that technology can enhance disease surveillance in resource-limited settings. PMID:26981628

  15. Effectiveness of a Mobile Short-Message-Service-Based Disease Outbreak Alert System in Kenya.

    PubMed

    Toda, Mitsuru; Njeru, Ian; Zurovac, Dejan; O-Tipo, Shikanga; Kareko, David; Mwau, Matilu; Morita, Kouichi

    2016-04-01

    We conducted a randomized, controlled trial to test the effectiveness of a text-messaging system used for notification of disease outbreaks in Kenya. Health facilities that used the system had more timely notifications than those that did not (19.2% vs. 2.6%), indicating that technology can enhance disease surveillance in resource-limited settings.

  16. Predominance of Enterobacteriaceae isolates in early positive anaerobic blood culture bottles in BacT/Alert system.

    PubMed

    Chiueh, Tzong-Shi; Lee, Shih-Yi; Tang, Sheng-Hui; Lu, Jang-Jih; Sun, Jun-Ren

    2013-03-01

    We collected and analyzed the time to detection (TTD) of blood cultures in the BacT/Alert automated system from 2002 to 2007. Among the 10,893 monomicrobial isolates from a total of 133,735 blood culture sets, the recoveries of aerobic bottles were compared with those of anaerobic bottles in this study. Significantly more Gram-positive cocci (except Staphylococcus aureus and enterococci), glucose nonfermentative Gram-negative bacteria, and yeast were recovered from aerobic bottles than from anaerobic bottles. The average TTD was 19.0 hr and 20.1 hr for the aerobic and anaerobic bottles, respectively, and 96.8% of the microorganisms were detected within the first 72 hr. Of the 5,489 microorganisms recovered from both of the blood culture bottle pair, microbial growth was significantly more often detected first in the anaerobic bottles than the aerobic bottles for Enterobacteriaceae except Serratia marcescens, while S. aureus, coagulase-negative staphylococci and Pseudomonas aeruginosa were more often detected first in the aerobic bottles. According to these data, we conclude that the earlier positivity of anaerobic bottles is a useful marker for rapid presumptive identification of Enterobacteriaceae infection.

  17. Utilization of a Pharmacy Clinical Surveillance System for Pharmacist Alerting and Communication at a Tertiary Academic Medical Center.

    PubMed

    Hohlfelder, Benjamin; Stashek, Chad; Anger, Kevin E; Szumita, Paul M

    2016-01-01

    The objective of this analysis is to describe the utilization metrics of a pharmacy clinical surveillance system (PCSS) at a tertiary, academic medical center.We performed a retrospective database analysis assessing rule-based alerts (RBA), interventions and pharmacist communication notes documented in the PCSS from January 1, 2014 to December 31, 2014. Reports were generated on 92 unique RBAs sent to clinicians for evaluation. Metrics assessed included the number of RBAs that were triggered, clinically evaluated, intervened on by pharmacists, and therapeutic category of interventions. Pharmacy communication notes were also evaluated.A total of 399,979 RBAs were triggered through the PCSS. During that time, pharmacists documented a total of 17,733 interventions. The most common RBAs were related to lab abnormalities (132,487; 33 %) and anticoagulation/antiplatelet therapy (126,425; 32.1 %). Interventions were most frequently related to RBAs regarding anticoagulation/antiplatelet therapy (6412; 36 %) and antimicrobial therapy (3320; 19 %). Pharmacist communication was most commonly related to clarification of medication and lab orders, and therapeutic drug monitoring.Based on utilization metrics presented, the implementation of a PCSS has successfully generated RBAs to aid pharmacists in clinical practice and improved departmental documentation and communication. Further analysis is warranted to assess the impact of the RBAs, interventions, and communication notes on outcomes such as hospital cost and adverse drug events.

  18. Should health systems agencies be involved in environmental health planning?

    PubMed Central

    Higgins, C W; Philips, B U; Bruhn, J G; Aker, L T

    1980-01-01

    Public Law 93-641 provides health systems agencies (HSAs) with a broad planning preview which has enabled a number of agencies to address environmental health issues in their health systems plans. Opponents of HSA involvement in environmental health planning charge that these activities overextend agency resources, duplicate efforts of other government agencies and involve HSAs in "issues of public policy." Closer examination of these charges finds them lacking in validity. The planning activities of health systems agencies are cooperative in nature, drawing upon the planning efforts of other institutions and agencies. It is illogical to exclude environmental concerns from general health planning in light of the impact of the environment upon health. Charges that issues of public policy are inappropriate topics for health planning are seen as attempts to avoid scrutiny of inconsistant legislative policies. Cooperative planning between health systems agencies and environmental health agencies is considered both desirable and essential for the development of effective health planning. PMID:7428743

  19. Procedures for analyzing the effectiveness of siren systems for alerting the public

    SciTech Connect

    Keast, D.N.; Towers, D.A.; Anderson, G.S.; Kenoyer, J.L.; Desrosiers, A.E.

    1982-09-01

    NUREG-0654, Revision 1 (Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants), Appendix 3, discusses requirements of the licensees to implement a prompt notification system within the 10-mile emergency planning zone (EPZ) surrounding a nuclear facility. Sirens are being installed for use as part of or as the entire notification system by many licensees. This report describes a procedure for predicting siren system effectiveness under defined conditions within the EPZ's. The procedure requires a good topographical map and knowledge of the meteorology, demographics, and human activity patterns within the EPZ. The procedure is intended to be applied to systems of sirens and to obtain average results for a large number (30 or more) of listener locations.

  20. Development of a Driver Alert System (DAS) for the Bradley Fighting Vehicle

    DTIC Science & Technology

    1988-07-01

    FIGHTING VEHICLE The survivability of a Bradley Fighting Vehicle (BFV) depends, in large part, on rapid response and movement in changing battle conditions...ARI Research Note 88-73 I6 0 Development of aDriver AertSystem CO (DAS) for the Bradley Fighting Vehicle * David F. Champion, Paul R. Roberson, and...System (DAS) Final Report for the Bradley Fighting Vehicle September 85 - September 87 6. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(s) 6. CONTRACT OR GRANT

  1. Evaluation of the prompt alerting systems at four nuclear power stations

    SciTech Connect

    Towers, D.A.; Anderson, G.S.; Keast, D.N.; Kenoyer, J.L.; Desrosiers, A.E.

    1982-09-01

    This report presents evaluations of the prompt notification siren systems at the following four US nuclear power facilities: Trojan, Three Mile Island, Indian Point, and Zion. The objective of these evaluations was to provide examples of an analytical procedure for predicting siren-system effectiveness under specific conditions in the 10-mile emergency planning zone (EPZ) surrounding nuclear power plants. This analytical procedure is discussed in report No. PNL-4227.

  2. Integration of Dust Prediction Systems and Vegetation Phenology to Track Pollen for Asthma Alerts in Public Health

    NASA Technical Reports Server (NTRS)

    Luvall, Jeffrey; Sprigg, William; Huete, Alfredo; Levetin, Estelle; VandeWater, Peter; Nickovic, Slobodan; Pejanovic, Goran; Budge, Amelia; Heidi Krapfl; Myers, Orrin; Losleben, Mark; Deaton, Tommie; Zelicoff, Alan

    2009-01-01

    Initial efforts to develop a deterministic model for predicting and simulating pollen release and downwind concentration to study dependencies of phenology on meteorology will be discussed. The development of a real-time, rapid response pollen release and transport system as a component of the New Mexico Environmental Public Health Tracking System (EPHTS), is based on meteorological models, NASA Earth science results (ESR), and an in-situ network of phenology cameras. The plan is to detect pollen release verified using ground based atmospheric pollen sampling within a few hours using daily MODIS daa in nearly real-time from Direct Broadcast, similar to the MODIS Rapid Response System for fire detection. As MODIS winds down, the NPOESS-VIIRS sensor will assume daily vegetation monitoring tasks. Also, advancements in geostationary satellites will allow 1km vegetation indices at 15-30 minute intervals. The pollen module in EPHTS will be used to: (1) support public health decisions for asthma and allergy alerts in New Mexico, Texas and Oklahoma; (2) augment the Centers for Disease Control and Prevention (CDC)'s Environmental Public Health Tracking Network (EPHTN); and (3) extend surveillance services to local healthcare providers subscribing to the Syndrome Reporting Information System (SYRIS). Previous studies in NASA's public health applications portfolios provide the infrastructure for this effort. The team is confident that NASA and NOAA ESR data, combined into a verified and validated dust model will yield groundbreaking results using the modified dust model to transport pollen. The growing ESR/health infrastructure is based on results from a rapid prototype scoping effort for pollen detection and simulation carried out by the principal investigators.

  3. A Virtual Audio Guidance and Alert System for Commercial Aircraft Operations

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Wenzel, Elizabeth M.; Shrum, Richard; Miller, Joel; Null, Cynthia H. (Technical Monitor)

    1996-01-01

    Our work in virtual reality systems at NASA Ames Research Center includes the area of aurally-guided visual search, using specially-designed audio cues and spatial audio processing (also known as virtual or "3-D audio") techniques (Begault, 1994). Previous studies at Ames had revealed that use of 3-D audio for Traffic Collision Avoidance System (TCAS) advisories significantly reduced head-down time, compared to a head-down map display (0.5 sec advantage) or no display at all (2.2 sec advantage) (Begault, 1993, 1995; Begault & Pittman, 1994; see Wenzel, 1994, for an audio demo). Since the crew must keep their head up and looking out the window as much as possible when taxiing under low-visibility conditions, and the potential for "blunder" is increased under such conditions, it was sensible to evaluate the audio spatial cueing for a prototype audio ground collision avoidance warning (GCAW) system, and a 3-D audio guidance system. Results were favorable for GCAW, but not for the audio guidance system.

  4. System designed for issuing landslide alerts in the San Francisco Bay area

    USGS Publications Warehouse

    Finley, D.

    1987-01-01

    A system for forecasting landslides during major storms has been developed for the San Francisco Bay area by the U.S Geological Survey and was successfully tested during heavy storms in the bay area during February 1986. Based on the forecasts provided by the USGS, the National Weather Service (NWS) included landslide warnings in its regular weather forecasts or in special weather statements transmitted to local radio and television stations and other news media. USGS scientists said the landslide forecasting and warning system for the San Francisco Bay area can be used as a prototype in developing similar systems for other parts of the Nation susceptible to landsliding. Studies show damage from landslides in the United States averages an estimated $1.5 billion per year. 

  5. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane...

  6. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane...

  7. Predictive Information: Status or Alert Information?

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.; Bruneau, Daniel; Press, Hayes N.

    2008-01-01

    Previous research investigating the efficacy of predictive information for detecting and diagnosing aircraft system failures found that subjects like to have predictive information concerning when a parameter would reach an alert range. This research focused on where the predictive information should be located, whether the information should be more closely associated with the parameter information or with the alert information. Each subject saw 3 forms of predictive information: (1) none, (2) a predictive alert message, and (3) predictive information on the status display. Generally, subjects performed better and preferred to have predictive information available although the difference between status and alert predictive information was minimal. Overall, for detection and recalling what happened, status predictive information is best; however for diagnosis, alert predictive information holds a slight edge.

  8. Evaluation of Helmet Mounted Display Alerting Symbology

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe; Rutkowski, Michael (Technical Monitor)

    2000-01-01

    Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.

  9. Worldwide Crisis Alerting Network, Phase II. Task 2. Identification of Existing Communications Systems,

    DTIC Science & Technology

    1980-04-01

    includes listings of U.S. and NATO country flag vessels, worldwide sea routes, probability of the number of vessels transiting ocean segments during...General Description Ownership MARISAT is a satellite-based system for communications between shore points and ships at sea . It is a commercial service...Services MARISAT provides general, distress and medical emergency communications capability for ships at sea . It also provides shore-to-ship

  10. ChemSem: an extensible and scalable RSS-based seminar alerting system for scientific collaboration.

    PubMed

    Rzepa, Henry S; Wheat, Andrew; Williamson, Mark J

    2006-01-01

    A seminar announcement system based on the extensive use of XML-based data structures, CML/MathML for carrying more domain-specific molecular content, and open source software components is described. The output is a resource description framework (RDF) site summary (RSS) feed, which potentially carries many advantages over conventional announcement mechanisms, including the ability to aggregate and then sort multiple and diverse RSS feeds on the basis of declared metadata and to feed into RDF-based mechanisms for establishing links between different subject areas.

  11. Development and Application of an Alert System to Detect Cases of Food Poisoning in Japan

    PubMed Central

    Akahane, Manabu; Sugiura, Hiroaki; Ohkusa, Yasushi; Okabe, Nobuhiko; Imamura, Tomoaki

    2016-01-01

    Recent public health concerns regarding commercial food products have increased the need to develop an automated method to detect food product-related health events. We developed and verified a method for the early detection of potentially harmful events caused by commercial food products. We collected data from daily internet-based questionnaires examining the presence or absence of symptoms and information about food purchased by the respondents. Using these data, we developed a method to detect possible health concerns regarding commercialized food products. To achieve this, we combined the signal detection method used in the reporting system of adverse effects of pharmaceutical products and the Early Aberration Reporting System (EARS) used by the United States Centers for Disease Control. Whiteleg shrimp (Litopenaeus vannamei), which had odds ratio and Odds(−) of 8.99 and 4.13, respectively, was identified as a possible causative food product for diarrhea and vomiting. In conclusion, this study demonstrated that food distributors can implement post-marketing monitoring of the safety of food products purchased via the internet. PMID:27231884

  12. Development and Application of an Alert System to Detect Cases of Food Poisoning in Japan.

    PubMed

    Maeyashiki, Akie; Akahane, Manabu; Sugiura, Hiroaki; Ohkusa, Yasushi; Okabe, Nobuhiko; Imamura, Tomoaki

    2016-01-01

    Recent public health concerns regarding commercial food products have increased the need to develop an automated method to detect food product-related health events. We developed and verified a method for the early detection of potentially harmful events caused by commercial food products. We collected data from daily internet-based questionnaires examining the presence or absence of symptoms and information about food purchased by the respondents. Using these data, we developed a method to detect possible health concerns regarding commercialized food products. To achieve this, we combined the signal detection method used in the reporting system of adverse effects of pharmaceutical products and the Early Aberration Reporting System (EARS) used by the United States Centers for Disease Control. Whiteleg shrimp (Litopenaeus vannamei), which had odds ratio and Odds(-) of 8.99 and 4.13, respectively, was identified as a possible causative food product for diarrhea and vomiting. In conclusion, this study demonstrated that food distributors can implement post-marketing monitoring of the safety of food products purchased via the internet.

  13. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the...

  14. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the...

  15. Best Practice for Rainfall Measurement, Torrential Flood Monitoring and Real Time Alerting System in Serbia

    NASA Astrophysics Data System (ADS)

    Stefanovic, Milutin; Milojevic, Mileta; Zlatanovic, Nikola

    2014-05-01

    Serbia occupies 88.000 km2 and its confined zone menaced with torrent flood occupies 50.000km2. Floods on large rivers and torrents are the most frequent natural disasters in Serbia. This is the result of a geographic position and relief of Serbia. Therefore, defense from these natural disasters has been institutionalized since the 19th century. Through its specialized bodies and public companies, the State organized defense from floods on large rivers and protection of international and other main roads. The Topčiderska River is one of a number of rivers in Serbia that is a threat to both urban and rural environments. In this text, general characteristics of this river will be illustrated, as well as the historical natural hazards that have occurred in the part of Belgrade near Topčiderska River. Belgrade is the capital of Serbia, its political, administrative and financial center, which means that there are significant financial capacities and human resources for investments in all sectors, and specially in the water resources sector. Along the Topčiderska catchment there are many industrial, traffic and residential structures that are in danger of floods and flood protection is more difficult with rapid high flows. The goal is to use monitoring on the Topčiderska River basin to set up a modern system for monitoring in real time and forecast of torrential floods. This paper represents a system of remote detection and monitoring of torrential floods and rain measurements in real time on Topciderka river and ready for a quick response.

  16. Use of the BacT/alert system for rapid detection of microbial contamination in a pilot study using pancreatic islet cell products.

    PubMed

    Murray, Laura; McGowan, Neil; Fleming, John; Bailey, Laura

    2014-10-01

    At the Islet Isolation Laboratory of the Scottish National Blood Transfusion Service, manual sterility testing data show that contamination rates are 57.7% for pancreas transport fluid, 4.3% for postpurification islet samples, and 0% for pretransplant islet samples. This pilot study presents the BacT/Alert System as an alternative to manual testing to provide more rapid and sensitive sterility results for islet cell products.

  17. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Active duty alerts. 1022.121 Section 1022.121 Banks and Banking BUREAU OF CONSUMER FINANCIAL PROTECTION FAIR CREDIT REPORTING (REGULATION V) Duties of Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration....

  18. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 8 2013-01-01 2013-01-01 false Active duty alerts. 1022.121 Section 1022.121 Banks and Banking BUREAU OF CONSUMER FINANCIAL PROTECTION FAIR CREDIT REPORTING (REGULATION V) Duties of Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration....

  19. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 8 2014-01-01 2014-01-01 false Active duty alerts. 1022.121 Section 1022.121 Banks and Banking BUREAU OF CONSUMER FINANCIAL PROTECTION FAIR CREDIT REPORTING (REGULATION V) Duties of Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration....

  20. 2 CFR 25.215 - Requirements for agency information systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 2 Grants and Agreements 1 2013-01-01 2013-01-01 false Requirements for agency information systems... information systems. Each agency that makes awards (as defined in § 25.325) must ensure that systems processing information related to the awards, and other systems as appropriate, are able to accept and...

  1. 2 CFR 25.215 - Requirements for agency information systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 2 Grants and Agreements 1 2012-01-01 2012-01-01 false Requirements for agency information systems... information systems. Each agency that makes awards (as defined in § 25.325) must ensure that systems processing information related to the awards, and other systems as appropriate, are able to accept and...

  2. Non-specific alert system for dengue epidemic outbreaks in areas of endemic malaria. A hospital-based evaluation in Cayenne (French Guiana).

    PubMed Central

    Carme, B.; Sobesky, M.; Biard, M. H.; Cotellon, P.; Aznar, C.; Fontanella, J. M.

    2003-01-01

    The emergence of dengue haemorrhagic fever is a public health problem in Latin America and the Caribbean. This study, carried out in French Guiana where malaria is endemic, evaluated the value and the limitations of a non-specific alert system including all patients admitted to the emergency department of Cayenne Hospital, between 1 January 1996 and June 2001. Four indices were studied on a weekly basis: the emergency malaria negative index (EMN), the EMN thrombocytopenia index (EMNT), the dengue suspected index: EMNT/EMN ratio; and the number of hospitalized patients with dengue fever according to the Department of Medical Information. These indices were retrospectively compared with data from the Arbovirus Reference Centre at the Pasteur Institute in French Guiana. Using the non-specific indices, we were able to identify four clear epidemics, two of which were shown to be linked to dengue. Variations in the incidence of malaria had no marked effect on this alert system. We propose that this simple, cheap, sensitive and reactive alert system be used to improve the serological and virological monitoring of dengue and to facilitate adequate and timely vector control measures. It could be used in all regions at risk of dengue and malaria. PMID:12613750

  3. Use of a Web-Based Academic Alert System for Identification of Underachieving Students at an Urban Research Institution

    ERIC Educational Resources Information Center

    Donnelly, John E.

    2010-01-01

    Early alert strategies are an increasingly common way to address students' ongoing needs for greater academic and social engagement by enabling a positive campus environment and appropriate academic support; Kuh et al. find these to be necessary engagement conditions. Young and Fry show the benefits of student metacognition, or awareness of…

  4. Echo Ranging/Probe Alert Performance Analysis.

    DTIC Science & Technology

    1982-11-04

    contract included technical analyses of acoustic communication equipment, system performance predictions, sea test design and data analysis, and...proposing functional system design alternatives. 2.0 SUMMARY OF WORK PERFORMED The JAYCOR effort focused on the analysis of the Echo Ranging/ Probe Alert...JAYCOR Document No. J640-020-82-2242, 16 August 1982, CONFIDENTIAL. 13. Probe Alert Design System Performance Estimates (U), J.L. Collins, JAYCOR Document

  5. Solar Radiation Alert System

    DTIC Science & Technology

    2005-07-01

    the earth’s atmosphere at high geomagnetic latitudes were calculated for the solar proton event of 20 January 2005. The event started at 06:50...excluding them does not significantly affect the calculated dose rates. The data are available in near real-time from the file transfer protocol (ftp...form a com- plete spectrum used to calculate effective doses in Step 9. A piecewise-continuous spectrum is needed because during solar proton events

  6. CISN ShakeAlert: Beta Test Users Receive Earthquake Early Warning Alerts and Provide Feedback for Improving Alert Delivery

    NASA Astrophysics Data System (ADS)

    Hellweg, M.; Vinci, M.; Allen, R. M.; Boese, M.; Henson, I. H.; Felizardo, C.

    2012-12-01

    Earthquake Early Warning (EEW) is the ability to detect an earthquake quickly and provide a few seconds of warning before destructive seismic waves arrive. The California Integrated Seismic Network (CISN) is implementing and testing a prototype system, the ShakeAlert system, which includes delivery of earthquake alerts to potential users. The alerts will be used to provide situational awareness, but also to automatically perform an operation that can impact personal safety or reduce losses to critical infrastructures and inventories. We are working with a group of 15 selected Beta Test Users from institutions and industries throughout California that have potential uses for EEW information. ShakeAlert Beta Test Users are currently running the ShakeAlert UserDisplay. In return, they provide feedback which includes suggestions to improve the UserDisplay and other alert delivery mechanisms, as well as information on their potential uses of EEW. Our currently most "advanced" user is the Bay Area Rapid Transit (BART) System. Their train control system now automatically slows and stops trains based on basic EEW information; EEW alerts are being added as an additional trigger. Beta Test User suggestions are incorporated into revisions of the UserDisplay and other elements of the ShakeAlert system, as appropriate. To form a knowledge base for EEW implementation into a public system, we also collect feedback detailing implementation costs and challenges within the Test User organizations, as well as anticipated benefits and savings. Thus, Beta Test Users are contributing to an operational Earthquake Early Warning system that will meet the needs of the public.

  7. Science Alerts with Gaia

    NASA Astrophysics Data System (ADS)

    Mignard, François

    2011-06-01

    Gaia is before all a survey mission designed to observe the sky in a continuous manner. The sky coverage results from the spin of the satellite over a period of 6h, combined with a much slower motion of the spin axis, allowing after six months complete sky coverage. The CCD counts are stored on-board and sent to the ground station every day during the visibility period of the spacecraft by the ground antenna. The satellite design has been optimized for a survey mission, with ground treatment and not for an immediate access to the data, let alone to some scientifically immediately usable information. The processing comprises several more or less independent pipelines, each involving some sort of global processing requiring the accumulation of a substantial amount of data over several weeks or months. However, it remains possible to carry out a quick, but crude in regard of the accuracy achievable on a longer term, analysis of the data stream arriving on the ground to detec! t transient phenomena, like photometric burst or fast motion of solar system objects. This dedicated processing, largely distinct from the general processing, and the associated validation systems put in place, is referred to as Science Alerts within the DPAC community.

  8. System of Earthquakes Alert (SEA) on the territory of Bulgaria developed as a result of DACEA project

    NASA Astrophysics Data System (ADS)

    Solakov, Dimcho; Dimitrova, Liliya; Simeonova, Stela; Aleksandrova, Irena; Stoyanov, Stoyan; Metodiev, Metodi

    2013-04-01

    The prevention of the natural disasters and the performing management of reactions to crisis are common problems for many countries. The Romania-Bulgaria border region is significantly affected by earthquakes occurred in both territories: on the one-hand, Vrancea seismic source, with intermediate-depth events and on the other hand, crustal seismicity recorded in the northern part of Bulgaria (Shabla, Dulovo, Gorna Orjahovitza). The general objective of DACEA (2010-2013) project is to develop an system of earthquake alert in order to prevent the natural disasters caused by earthquakes in the cross-border area, taking into account the nuclear power plants and other chemical plants located along the Danube on the territories of Romania and Bulgaria. An integrated warning system is designed and implemented in the cross-border area. A seismic detection network is put in operation in order to warn the bodies in charge with emergency situations management in case of seismic danger. The main purpose of this network is: • monitoring of the four seismogenic areas relevant for the cross-border area, in order to detect dangerous earthquakes • sending the seismic warning signals within several seconds to the local public authorities in the cross-border area On the territory of Bulgaria the seismic network belonging to SEA is consists of: • 8 seismic stations equipped with Basalt digitizer, accelerometer Epi-sensor and BB seismometer KS2000. • 8 seismic stations equipped with Basalt digitizer, accelerometer Epi-sensor, warning and visual monitoring equipment. The stations are spanned allover the North Bulgaria. The sites were thoroughly examined and the most important requirement was the low level of noise or vibrations. SEA centers were established both in Sofia (in National Institute of Geophysics, Geodesy and Geography - NIGGG) and Bucharest (in National Institute of Research and Development for Earth Physics). Both centers are equipped with servers for data analyses

  9. Integration of Dust Prediction Systems and Vegetation Phenology to Track Pollen for Asthma Alerts in Public Health

    NASA Technical Reports Server (NTRS)

    Luvall, Jeffrey C.; Sprigg, W. A.; Huete, A.; Nickovic, S.; Pejanovic, G.; Levetin, E.; Van de water, P.; Myers, O.; Budge, A. M.; Krapfl, H.; Crimmins, T. M.

    2011-01-01

    Pollen can be transported great distances. Van de Water et. al., 2003 reported Juniperus pollen, a significant aeroallergen was transported 200-600 km. Hence local observations of plant phenology may not be consistent with the timing and source of pollen collected by pollen sampling instruments. The DREAM (Dust REgional Atmospheric Model, Yin 2007) is a verified model for atmospheric dust transport modeling using MODIS data products to identify source regions and quantities of dust (Yin 2007). The use of satellite data products for studying phenology is well documented (White and Nemani 2006). We are modifying the DREAM model to incorporate pollen transport. The linkages already exist with DREAM through PHAiRS (Public Health Applications in remote Sensing) to the public health community. This linkage has the potential to fill this data gap so that health effects of pollen can better be tracked for linkage with health outcome data including asthma, respiratory effects, myocardial infarction, and lost work days. DREAM is based on the SKIRON/Eta modeling system and the Eta/NCEP regional atmospheric model. The dust modules of the entire system incorporate the state of the art parameterizations of all the major phases of the atmospheric dust life such as production, diffusion, advection, and removal. These modules also include effects of the particle size distribution on aerosol dispersion. The dust production mechanism is based on the viscous/turbulent mixing, shear-free convection diffusion, and soil moisture. In addition to these sophisticated mechanisms, very high resolution databases, including elevation, soil properties, and vegetation cover are utilized. The DREAM model was modified to use pollen sources instead of dust (PREAM). Pollen release will be estimated based on satellite-derived phenology of Juniperus spp. communities. The MODIS surface reflectance product (MOD09) will provide information on the start of the plant growing season, growth stage, peak

  10. Evaluation of a plastic nonvented aerobic blood culture bottle for use with the BacT/ALERT microbial detection system.

    PubMed

    Snyder, J W; Munier, G K; Bostic, G D; Bozigar, P S; Hanna, R

    2002-12-01

    The current BacT/ALERT SA (BTA SA) aerobic blood culture bottle is made from glass, does not require venting, and contains a liquid emulsion sensor (LES). Its performance has been shown to be equivalent to that of the vented standard aerobic culture bottle. A further-improved version of the BTA SA bottle, designated the BacT/ALERT plastic SA (BTA PSA) culture bottle, is made from clear plastic to prevent breakage, does not require venting, and contains a modified LES (LES 2) to reduce the possibility of false positives. The BTA PSA provides a practical alternative to the current glass version of this bottle. The plastic bottle is also comparable to the current glass bottle in transparency and growth performance and additionally minimizes the exposure to infectious agents due to glass bottle breakage.

  11. 75 FR 2105 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-14

    ... Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector General (OIG... Special Fraud Alert addressing telemarketing by durable medical equipment (DME) suppliers. For the most part, OIG Special Fraud Alerts address national trends in health care fraud, including...

  12. 76 FR 81904 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-29

    ... Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION: Notice of intent to develop... Social Security Act), as well as developing new OIG Special Fraud Alerts. DATES: To assure consideration... recommendations for developing new or revised safe harbors and Special Fraud Alerts. Please assist us...

  13. 5 CFR 430.312 - OPM review of agency systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 430.312 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.312 OPM review of agency systems. (a) Agencies must submit proposed SES performance management systems to OPM for approval. (b) OPM will...

  14. 5 CFR 430.312 - OPM review of agency systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Section 430.312 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.312 OPM review of agency systems. (a) Agencies must submit proposed SES performance management systems to OPM for approval. (b) OPM will...

  15. 2 CFR 25.215 - Requirements for agency information systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Requirements for agency information systems... information related to the awards, and other systems as appropriate, are able to accept and use the DUNS... UNIVERSAL IDENTIFIER AND CENTRAL CONTRACTOR REGISTRATION Policy § 25.215 Requirements for agency...

  16. Flate-plate photovoltaic power systems handbook for Federal agencies

    NASA Technical Reports Server (NTRS)

    Cochrane, E. H.; Lawson, A. C.; Savage, C. H.

    1984-01-01

    The primary purpose is to provide a tool for personnel in Federal agencies to evaluate the viability of potential photovoltaic applications. A second objective is to provide descriptions of various photovoltaic systems installed by different Federal agencies under the Federal Photovoltaic Utilization Program so that other agencies may consider similar applications. A third objective is to share lessons learned to enable more effective procurement, design, installation, and operation of future photovoltaic systems. The intent is not to provide a complete handbook, but rather to provide a guide for Federal agency personnel with additional information incorporated by references. The steps to be followed in selecting, procuring, and installing a photovoltaic application are given.

  17. Multilingual Video and Audio News Alerting

    DTIC Science & Technology

    2004-01-01

    enable searching of multilingual video news sources by a monolingual speaker. In addition to full search capabilities, the system also enables real... Multilingual Video and Audio News Alerting David D. Palmer, Patrick Bray, Marc Reichman, Katherine Rhodes, Noah White Virage Advanced...DATE 2004 2. REPORT TYPE 3. DATES COVERED 00-00-2004 to 00-00-2004 4. TITLE AND SUBTITLE Multilingual Video and Audio News Alerting 5a

  18. Reducing Unnecessary and Duplicate Ordering for Ovum and Parasite Examinations and Clostridium difficile PCR in Immunocompromised Patients by Using an Alert at the Time of Request in the Order Management System.

    PubMed

    Otto, Caitlin C; Shuptar, Susan L; Milord, Philippe; Essick, Connor J; Nevrekar, Reshma; Granovsky, Svetlana L; Seo, Susan K; Babady, N Esther; Martin, Steven C; Tang, Yi-Wei; Pessin, Melissa S

    2015-08-01

    We implemented hospital information system (HIS) alerts to deter unnecessary test orders for ovum and parasite (O&P) exams and Clostridium difficile PCR. The HIS alerts decreased noncompliant O&P orders (orders after >72 h of hospitalization) from 49.8% to 30.9%, an overall decrease of 19%, and reduced noncompliant C. difficile PCR orders (orders <7 days after a previous positive result) from 30.6% to 19.2%, an overall decrease of 31.9%.

  19. An electronic alert to decrease Kayexalate ordering

    PubMed Central

    Leaf, David E.; Cheng, Xingxing S.; Sanders, Jason L.; Mendu, Mallika; Schiff, Gordon D.; Mount, David B.; Bazari, Hasan

    2016-01-01

    Important safety concerns have recently emerged regarding the use of sodium polystyrene sulfonate (Kayexalate), a cation-exchange resin commonly used for the treatment of hyperkalemia. We implemented an electronic alert system at a tertiary care academic medical center to warn providers of the safety concerns of Kayexalate. We assessed the number of Kayexalate prescriptions per month, as well as the number of grams of Kayexalate ordered per month, one year before versus one year after implementing the alert. The mean (±SD) number of Kayexalate orders decreased from 123 (±12) to 76 (±14) orders/month (38% absolute reduction, p < 0.001) after implementing the alert. Additionally, the mean (±SD) amount of Kayexalate prescribed decreased from 3332 (±329) to 1885 (±358) g/month (43% absolute reduction, p < 0.001). We conclude that an electronic alert is an effective tool to decrease Kayexalate ordering. PMID:27183825

  20. Prototype Conflict Alerting Logic for Free Flight

    NASA Technical Reports Server (NTRS)

    Yang, Lee C.; Kuchar, James K.

    1997-01-01

    This paper discusses the development of a prototype alerting system for a conceptual Free Flight environment. The concept assumes that datalink between aircraft is available and that conflicts are primarily resolved on the flight deck. Four alert stages are generated depending on the likelihood of a conflict. If the conflict is not resolved by the flight crews, Air Traffic Control is notified to take over separation authority. The alerting logic is based on probabilistic analysis through modeling of aircraft sensor and trajectory uncertainties. Monte Carlo simulations were used over a range of encounter situations to determine conflict probability. The four alert stages were then defined based on probability of conflict and on the number of avoidance maneuvers available to the flight crew. Preliminary results from numerical evaluations and from a piloted simulator study at NASA Ames Research Center are summarized.

  1. Transient Alerts in LSST

    NASA Astrophysics Data System (ADS)

    Kantor, J.

    During LSST observing, transient events will be detected and alerts generated at the LSST Archive Center at NCSA in Champaign-Illinois. As a very high rate of alerts is expected, approaching ˜ 10 million per night, we plan for VOEvent-compliant Distributor/Brokers (http://voevent.org) to be the primary end-points of the full LSST alert streams. End users will then use these Distributor/Brokers to classify and filter events on the stream for those fitting their science goals. These Distributor/Brokers are envisioned to be operated as a community service by third parties who will have signed MOUs with LSST. The exact identification of Distributor/Brokers to receive alerts will be determined as LSST approaches full operations and may change over time, but it is in our interest to identify and coordinate with them as early as possible. LSST will also operate a limited Distributor/Broker with a filtering capability at the Archive Center, to allow alerts to be sent directly to a limited number of entities that for some reason need to have a more direct connection to LSST. This might include, for example, observatories with significant follow-up capabilities whose observing may temporarily be more directly tied to LSST observing. It will let astronomers create simple filters that limit what alerts are ultimately forwarded to them. These user defined filters will be possible to specify using an SQL-like declarative language, or short snippets of (likely Python) code. We emphasize that this LSST-provided capability will be limited, and is not intended to satisfy the wide variety of use cases that a full-fledged public Event Distributor/Broker could. End users will not be able to subscribe to full, unfiltered, alert streams coming directly from LSST. In this session, we will discuss anticipated LSST data rates, and capabilities for alert processing and distribution/brokering. We will clarify what the LSST Observatory will provide versus what we anticipate will be a

  2. Porphyrin entrapment and release behavior of microporous organic hollow spheres: fluorescent alerting systems for existence of organic solvents in water.

    PubMed

    Jin, Jaewon; Kim, Bolyong; Park, Nojin; Kang, Sungah; Park, Joon Hyun; Lee, Sang Moon; Kim, Hae Jin; Son, Seung Uk

    2014-12-07

    This work reports on the controllable guest entrapment and release behavior of microporous organic hollow spheres (MOHs). Porphyrins which are soluble in both water and methanol were entrapped in the MOHs using methanol solution. The water-soluble porphyrins entrapped in MOHs were not extracted by water due to the hydrophobicity of microporous organic shells. In contrast, the porphyrins were released gradually into aqueous solution by adding water-soluble organic solvents. The release behavior depended on the kind of organic solvents used and on the alkyl chain length of the porphyrin compounds. These properties were applied for the fluorescent alert towards the existence of organic solvents in flowing aqueous media.

  3. Understanding Learner Agency as a Complex Dynamic System

    ERIC Educational Resources Information Center

    Mercer, Sarah

    2011-01-01

    This paper attempts to contribute to a fuller understanding of the nature of language learner agency by considering it as a complex dynamic system. The purpose of the study was to explore detailed situated data to examine to what extent it is feasible to view learner agency through the lens of complexity theory. Data were generated through a…

  4. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    PubMed Central

    Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.

    2017-01-01

    Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887

  5. Defense Intelligence Agency Integrated Scheduling System

    DTIC Science & Technology

    1990-12-01

    92 / / OK 03/29/91/09:58:43 A2-2 12/DSNET 3 Dependency Status Report 03/31/91 apendent Project Dependent Milestone Baseline Current Actual Status 12...f / " i:!- " : I AD-A245 515’ IlE II I 1 11lnll l IHl RL-TR-91-324 Final Technical Report Decembw 191 DEFENSE INTELLIGENCE AGENCY INTEGRATED...Air Force Base, NY 13441-5700 92 1 31 072 This report has been reviewed by the Rome Laboratory Public Affairs Office (PA) and is releasable to the

  6. Global Environmental Alert Service

    NASA Astrophysics Data System (ADS)

    Grasso, V. F.; Cervone, G.; Singh, A.; Kafatos, M.

    2006-12-01

    Environmental Alert Service (GEAS) that could provide information from monitoring, Earth observing and early warning systems to users in a near real time mode and bridge the gap between the scientific community and policy makers. Characteristics and operational aspects of GEAS are discussed.

  7. Project "Hypertension Alert."

    ERIC Educational Resources Information Center

    Sailors, Emma Lou

    1983-01-01

    "Hypertension Alert," a 1979-80 blood pressure screening-awareness project of the Yonkers, New York Public Schools, is described. Data is analyzed in tables for ethnic composition, and range of blood pressure readings for the high school, junior high school, and elementary school students tested. (Author/JMK)

  8. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  9. With Free Google Alert Services

    ERIC Educational Resources Information Center

    Gunn, Holly

    2005-01-01

    Alert services are a great way of keeping abreast of topics that interest you. Rather than searching the Web regularly to find new content about your areas of interest, an alert service keeps you informed by sending you notices when new material is added to the Web that matches your registered search criteria. Alert services are examples of push…

  10. ToxAlerts: A Web Server of Structural Alerts for Toxic Chemicals and Compounds with Potential Adverse Reactions

    PubMed Central

    2012-01-01

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly

  11. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Agency performance appraisal system(s... REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and Certain Other Employees § 430.204 Agency performance appraisal system(s). (a) Each agency as defined at...

  12. NA22 Model Cities Project - LL244T An Intelligent Transportation System-Based Radiation Alert and Detection System

    SciTech Connect

    Peglow, S

    2004-02-24

    The purpose of this project was twofold: first, provide an understanding of the technical foundation and planning required for deployment of Intelligent Transportation System (ITS)-based system architectures for the protection of New York City from a terrorist attack using a vehicle-deployed nuclear device; second, work with stakeholders to develop mutual understanding of the technologies and tactics required for threat detection/identification and establish guidelines for designing operational systems and procedures. During the course of this project we interviewed and coordinated analysis with people from the New Jersey State Attorney General's office, the New Jersey State Police, the Port Authority of New York/New Jersey, the Counterterrorism Division of the New York City Police Department, the New Jersey Transit Authority, the State of New Jersey Department of Transportation, TRANSCOM and a number of contractors involved with state and federal intelligent transportation development and implementation. The basic system architecture is shown in the figure below. In an actual system deployment, radiation sensors would be co-located with existing ITS elements and the data will be sent to the Traffic Operations Center. A key element of successful system operation is the integration of vehicle data, such as license plate, EZ pass ID, vehicle type/color and radiation signature. A threat data base can also be implemented and utilized in cases where there is a suspect vehicle identified from other intelligence sources or a mobile detector system. Another key aspect of an operational architecture is the procedures used to verify the threat and plan interdiction. This was a major focus of our work and discussed later in detail. In support of the operational analysis, we developed a detailed traffic simulation model that is described extensively in the body of the report.

  13. Volcanic alert in antarctica

    NASA Astrophysics Data System (ADS)

    Bush, Susan

    1992-01-01

    On January 14, members of the Council of Managers of National Antarctic Programs (COMNAP) were alerted to possible volcanic activity on Deception Island, Antarctica. The island, located at latitude 62%57‧S, longitude 60'40‧W, attracts many tourists.COMNAP is a group of national program managers of 25 countries that have government programs in the Antarctic. Its function is to implement measures adopted by the Antarctic Treaty parties, including fostering international cooperation in scientific research.

  14. Rape Survivors' Agency within the Legal and Medical Systems

    ERIC Educational Resources Information Center

    Greeson, Megan R.; Campbell, Rebecca

    2011-01-01

    Many rape survivors seek help from the legal and medical systems post-assault. Previous studies have examined how social system personnel treat survivors, but less attention has been paid to how survivors attempt to shape their interactions with these systems. The purpose of this qualitative study was to examine rape survivors' agency--the active…

  15. Defense Information Systems Agency Management of Trouble Tickets for Electronic Commerce/Electronic Data Interchange

    DTIC Science & Technology

    2007-11-02

    Institute CSC Customer Service Center DISA Defense Information Systems Agency DLA Defense Logistics Agency EC/EDI Electronic Commerce / Electronic Data...INFORMATION SYSTEMS AGENCY SUBJECT: *Audit Report on the Defense Information Systems Agency Management of Trouble Tickets for the Electronic Commerce ...Information Systems Agency Management of Trouble Tickets for Electronic Commerce / Electronic Data Interchange Executive Summary Introduction. The Deputy

  16. Integration for Airborne Dust Prediction Systems and Vegetation Phenology to Track Pollen for Asthma Alerts in Public Health Decision Support Systems

    NASA Technical Reports Server (NTRS)

    Luvall, J. C.; Sprigg, W. A.; Nickovic, S.; Huete, A.; Budge, A.; Flowers, L.

    2008-01-01

    The objective of the program is to assess the feasibility of combining a dust transport model with MODIS derived phenology to study pollen transport for integration with a public health decision support system. The use of pollen information has specifically be identified as a critical need by the New Mexico State Health department for inclusion in the Environmental Public Health Tracking (EPHT) program. Material and methods: Pollen can be transported great distances. Local observations of plan phenology may be consistent with the timing and source of pollen collected by pollen sampling instruments. The Dust REgional Atmospheric Model (DREAM) is an integrated modeling system designed to accurately describe the dust cycle in the atmosphere. The dust modules of the entire system incorporate the state of the art parameterization of all the major phases of the atmospheric dust life such as production, diffusion, advection, and removal. These modules also include effects of the particles size distribution on aerosol dispersion. The model was modified to use pollen sources instead of dust. Pollen release was estimated based on satellite-derived phenology of key plan species and vegetation communities. The MODIS surface reflectance product (MOD09) provided information on the start of the plant growing season, growth stage, and pollen release. The resulting deterministic model is useful for predicting and simulating pollen emission and downwind concentration to study details of phenology and meteorology and their dependencies. The proposed linkage in this project provided critical information on the location timing and modeled transport of pollen directly to the EPHT> This information is useful to support the centers for disease control and prevention (CDC)'s National EPHT and the state of New Mexico environmental public health decision support for asthma and allergies alerts.

  17. 75 FR 12770 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, OMB No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ... Review; Comment Request, OMB No. 1660-NEW; Radiological Emergency Preparedness Program Alert and... Preparedness Program Alert and Notification Phone Survey. SUMMARY: The Federal Emergency Management Agency...: Collection of Information Title: Radiological Emergency Preparedness Program Alert and Notification...

  18. For Emergency Alerts, Some Colleges Try Sirens

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2008-01-01

    Colleges and universities, ever more mindful of campus safety, are installing outdoor sirens. The systems can blast spoken messages or tone alerts of danger--and one of the preset messages on many of the public-address systems warns: "There is a shooter on campus. Seek shelter immediately." As college officials reviewed their…

  19. Elements of a Model State Education Agency Diffusion System.

    ERIC Educational Resources Information Center

    Mojkowski, Charles

    A study, presented to the National Dissemination Conference, provides a conceptualization of a model diffusion system as it might exist within a state education agency (SEA) and places this diffusion model within the context of the SEA's expanding role as an educational service. Five conclusions were reached regarding a model diffusion system.…

  20. Integrating child health information systems in public health agencies.

    PubMed

    Bara, Debra; McPhillips-Tangum, Carol; Wild, Ellen L; Mann, Marie Y

    2009-01-01

    Public health agencies at state and local levels are integrating information systems to improve health outcomes for children. An assessment was conducted to describe the extent to which public health agencies are currently integrating child health information systems (CHIS). Using online technology information was collected, to assess completed and planned activities related to integration of CHIS, maturity of these systems, and factors that influence decisions by public health agencies to pursue integration activities. Of the 39 public health agencies that participated, 18 (46%) reported already integrating some or all of their CHIS, and 13 (33%) reported to be planning to integrate during the next 3 years. Information systems most commonly integrated include Early Hearing Detection and Intervention (EHDI), immunization, vital records, and Newborn Dried Bloodspot Screening (NDBS). Given the high priority that has been placed on using technology to improve health status in the United States, the emphasis on expanding the capability for the electronic exchange of health information, and federal support for electronic health records by 2014, public health agencies should be encouraged and supported in their efforts to develop, implement, and maintain integrated CHIS to facilitate the electronic exchange of health information with the clinical healthcare sector.

  1. 78 FR 25749 - Submission of New Drug Application/Abbreviated New Drug Application Field Alert Reports: Notice...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-02

    ... Application Field Alert Reports: Notice of Form FDA 3331--Automated Pilot Program AGENCY: Food and Drug... submit new drug application (NDA) and abbreviated new drug application (ANDA) Field Alert Reports (FARs... program should be sent to district Drug Field Alert Monitors (contact information for each of...

  2. Seismological results from the records obtained by the Seismic Alert System of Mexico (SASMEX). The analysis of the earthquake of March 20, 2012 and other examples

    NASA Astrophysics Data System (ADS)

    Ramos Perez, S.; Rodriguez Gonzalez, M.; Uribe Carvajal, A.; Espinosa Aranda, J.; Cuellar Martinez, A.

    2013-05-01

    In this talk we show seismological processes performed with data obtained from the records collected by the strong motion recorders that constitute the seismic alert system of Mexico (SASMEX). The instruments and the triggering algorithms are original design of CIRES, This has allowed that optimal time modifications, improvements and error corrections. Punctual parameters as first time arrivals, S-P times, and maximum acceleration (Amax) for each seismic station can be obtained from the warning record it self, before the earthquake arrives. When the system initiates the alert process the S-P time at least two sites are already known and at this moment common time is set in all the array which allows the synchronization of all the records, these are recovered during field trips after every trigger. The time histories are obtained by A/D converters (12 bits) and MEMS accelerometers. During the March 20, 2012 earthquake nine seismic stations of the SASMEX array detected the event at less than one hundred kilometres of epicentral distance, this allowed to calculate the location of the hypocenter, the maxima displacements associated to each of these sites. The greatest value corresponds to the Llano Grande seismic station, 0.47m on the SW direction, for the NS component. The distributions of Amax and the estimated movement displacement are shown. The foreshock of October 6 is also analysed, The behaviour of the SASMEX during the earthquakes of Tehuacan (June 15, 1999) and of Guatemala (Nov 7, 2012) are shown as examples of the possibility that the nature of the seismic activity it self point the need and probable success of increasing the coverage of SASMEX.

  3. Implementing national patient safety alerts.

    PubMed

    Moore, Sally; Taylor, Natalie; Lawton, Rebecca; Slater, Beverley

    National patient safety alerts are sometimes difficult to implement in an effective way. All trusts have to declare compliance with alerts as part of a three-step process to improve patient safety. This article discusses an alternative way of implementing national patient safety alerts and describes how behaviour-change methods can be used to successfully implement lasting changes in practice at ward or departmental level.

  4. Reducing Unnecessary and Duplicate Ordering for Ovum and Parasite Examinations and Clostridium difficile PCR in Immunocompromised Patients by Using an Alert at the Time of Request in the Order Management System

    PubMed Central

    Shuptar, Susan L.; Milord, Philippe; Essick, Connor J.; Nevrekar, Reshma; Granovsky, Svetlana L.; Seo, Susan K.; Martin, Steven C.; Pessin, Melissa S.

    2015-01-01

    We implemented hospital information system (HIS) alerts to deter unnecessary test orders for ovum and parasite (O&P) exams and Clostridium difficile PCR. The HIS alerts decreased noncompliant O&P orders (orders after >72 h of hospitalization) from 49.8% to 30.9%, an overall decrease of 19%, and reduced noncompliant C. difficile PCR orders (orders <7 days after a previous positive result) from 30.6% to 19.2%, an overall decrease of 31.9%. PMID:26063860

  5. Delivering Alert Messages to Members of a Work Force

    NASA Technical Reports Server (NTRS)

    Loftis, Julia; Nickens, Stephanie; Pell, Melissa; Pell, Vince

    2008-01-01

    Global Alert Resolution Network (GARNET) is a software system for delivering emergency alerts as well as less-urgent messages to members of the Goddard Space Flight Center work force via an intranet or the Internet, and can be adapted to similar use in other large organizations.

  6. Thermodynamic Alerter for Microbursts (TAMP)

    NASA Technical Reports Server (NTRS)

    Eccles, Peter J.

    1991-01-01

    The following subject areas are covered: microburst detection, location and measurement; thermal alerter for microbursts prototypes (TAMP); sensor-transmitters (Senstrans) design; TAMP installation; and DAPAD software.

  7. CEI-PEA Alert, Fall 2005

    ERIC Educational Resources Information Center

    Center for Educational Innovation - Public Education Association, 2005

    2005-01-01

    The "CEI-PEA Alert" is an advocacy newsletter that deals with topics of interest to all concerned with the New York City public schools. This issue includes: (1) Chancellor Joel I. Klein Announces New Accountability System for NYC Schools; (2) Students Achieve Record-High Scores!; (3) Use Data to Help Your Child Improve Performance; (4)…

  8. 2 CFR 25.215 - Requirements for agency information systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 2 Grants and Agreements 1 2011-01-01 2011-01-01 false Requirements for agency information systems. 25.215 Section 25.215 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS...

  9. Prioritizing earthquake and tsunami alerting efforts

    NASA Astrophysics Data System (ADS)

    Allen, R. M.; Allen, S.; Aranha, M. A.; Chung, A. I.; Hellweg, M.; Henson, I. H.; Melgar, D.; Neuhauser, D. S.; Nof, R. N.; Strauss, J. A.

    2015-12-01

    The timeline of hazards associated with earthquakes ranges from seconds for the strong shaking at the epicenter, to minutes for strong shaking at more distant locations in big quakes, to tens of minutes for a local tsunami. Earthquake and tsunami warning systems must therefore include very fast initial alerts, while also taking advantage of available time in bigger and tsunami-generating quakes. At the UC Berkeley Seismological Laboratory we are developing a suite of algorithms to provide the fullest possible information about earthquake shaking and tsunami inundation from seconds to minutes after a quake. The E-larmS algorithm uses the P-wave to rapidly detect an earthquake and issue a warning. It is currently issuing alerts to test users in as little as 3 sec after the origin time. Development of a new waveform detector may lead to even faster alerts. G-larmS uses permanent deformation estimates from GNSS stations to estimate the geometry and extent of rupture underway providing more accurate ground shaking estimates in big (M>~7) earthquakes. It performed well in the M6.0 2014 Napa earthquake. T-larmS is a new algorithm designed to extend alert capabilities to tsunami inundation. Rapid estimates of source characteristics for subduction zones event can not only be used to warn of the shaking hazard, but also the local tsunami inundation hazard. These algorithms are being developed, implemented and tested with a focus on the western US, but are also now being tested in other parts of the world including Israel, Turkey, Korea and Chile. Beta users in the Bay Area are receiving the alerts and beginning to implement automated actions. They also provide feedback on users needs, which has led to the development of the MyEEW smartphone app. This app allows beta users to receive the alerts on their cell phones. All these efforts feed into our ongoing assessment of directions and priorities for future development and implementation efforts.

  10. Unmanned Aircraft Systems Human-in-the-Loop Controller and Pilot Acceptability Study: Collision Avoidance, Self-Separation, and Alerting Times (CASSAT)

    NASA Technical Reports Server (NTRS)

    Comstock, James R., Jr.; Ghatas, Rania W.; Vincent, Michael J.; Consiglio, Maria C.; Munoz, Cesar; Chamberlain, James P.; Volk, Paul; Arthur, Keith E.

    2016-01-01

    The Federal Aviation Administration (FAA) has been mandated by the Congressional funding bill of 2012 to open the National Airspace System (NAS) to Unmanned Aircraft Systems (UAS). With the growing use of unmanned systems, NASA has established a multi-center "UAS Integration in the NAS" Project, in collaboration with the FAA and industry, and is guiding its research efforts to look at and examine crucial safety concerns regarding the integration of UAS into the NAS. Key research efforts are addressing requirements for detect-and-avoid (DAA), self-separation (SS), and collision avoidance (CA) technologies. In one of a series of human-in-the-loop experiments, NASA Langley Research Center set up a study known as Collision Avoidance, Self-Separation, and Alerting Times (CASSAT). The first phase assessed active air traffic controller interactions with DAA systems and the second phase examined reactions to the DAA system and displays by UAS Pilots at a simulated ground control station (GCS). Analyses of the test results from Phase I and Phase II are presented in this paper. Results from the CASSAT study and previous human-in-the-loop experiments will play a crucial role in the FAA's establishment of rules, regulations, and procedures to safely, efficiently, and effectively integrate UAS into the NAS.

  11. Evaluation of epidemic intelligence systems integrated in the early alerting and reporting project for the detection of A/H5N1 influenza events.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P; Hartley, David M; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Yangarber, Roman; Astagneau, Pascal

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7-13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users.

  12. Toxic substances alert program

    NASA Technical Reports Server (NTRS)

    Junod, T. L.

    1978-01-01

    A toxicity profile is provided, of 187 toxic substances procured by NASA Lewis Research Center during a 3 1/2 year period, including 27 known or suspected carcinogens. The goal of the program is to assure that the center's health and safety personnel are aware of the procurement and use of toxic substances and to alert and inform the users of these materials as to the toxic characteristics and the control measures needed to ensure their safe use. The program also provides a continuing record of the toxic substances procured, who procured them, what other toxic substances the user has obtained in the past, and where similar materials have been used elsewhere at the center.

  13. Computational Approach to Structural Alerts: Furans, Phenols, Nitroaromatics, and Thiophenes.

    PubMed

    Dang, Na Le; Hughes, Tyler B; Miller, Grover P; Swamidass, S Joshua

    2017-03-14

    Structural alerts are commonly used in drug discovery to identify molecules likely to form reactive metabolites and thereby become toxic. Unfortunately, as useful as structural alerts are, they do not effectively model if, when, and why metabolism renders safe molecules toxic. Toxicity due to a specific structural alert is highly conditional, depending on the metabolism of the alert, the reactivity of its metabolites, dosage, and competing detoxification pathways. A systems approach, which explicitly models these pathways, could more effectively assess the toxicity risk of drug candidates. In this study, we demonstrated that mathematical models of P450 metabolism can predict the context-specific probability that a structural alert will be bioactivated in a given molecule. This study focuses on the furan, phenol, nitroaromatic, and thiophene alerts. Each of these structural alerts can produce reactive metabolites through certain metabolic pathways but not always. We tested whether our metabolism modeling approach, XenoSite, can predict when a given molecule's alerts will be bioactivated. Specifically, we used models of epoxidation, quinone formation, reduction, and sulfur-oxidation to predict the bioactivation of furan-, phenol-, nitroaromatic-, and thiophene-containing drugs. Our models separated bioactivated and not-bioactivated furan-, phenol-, nitroaromatic-, and thiophene-containing drugs with AUC performances of 100%, 73%, 93%, and 88%, respectively. Metabolism models accurately predict whether alerts are bioactivated and thus serve as a practical approach to improve the interpretability and usefulness of structural alerts. We expect that this same computational approach can be extended to most other structural alerts and later integrated into toxicity risk models. This advance is one necessary step toward our long-term goal of building comprehensive metabolic models of bioactivation and detoxification to guide assessment and design of new therapeutic

  14. Alerts of forest disturbance from MODIS imagery

    NASA Astrophysics Data System (ADS)

    Hammer, Dan; Kraft, Robin; Wheeler, David

    2014-12-01

    This paper reports the methodology and computational strategy for a forest cover disturbance alerting system. Analytical techniques from time series econometrics are applied to imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor to detect temporal instability in vegetation indices. The characteristics from each MODIS pixel's spectral history are extracted and compared against historical data on forest cover loss to develop a geographically localized classification rule that can be applied across the humid tropical biome. The final output is a probability of forest disturbance for each 500 m pixel that is updated every 16 days. The primary objective is to provide high-confidence alerts of forest disturbance, while minimizing false positives. We find that the alerts serve this purpose exceedingly well in Pará, Brazil, with high probability alerts garnering a user accuracy of 98 percent over the training period and 93 percent after the training period (2000-2005) when compared against the PRODES deforestation data set, which is used to assess spatial accuracy. Implemented in Clojure and Java on the Hadoop distributed data processing platform, the algorithm is a fast, automated, and open source system for detecting forest disturbance. It is intended to be used in conjunction with higher-resolution imagery and data products that cannot be updated as quickly as MODIS-based data products. By highlighting hotspots of change, the algorithm and associated output can focus high-resolution data acquisition and aid in efforts to enforce local forest conservation efforts.

  15. Self-Alert Training: Volitional Modulation of Autonomic Arousal Improves Sustained Attention

    ERIC Educational Resources Information Center

    O'Connell, Redmond G.; Bellgrove, Mark A.; Dockree, Paul M.; Lau, Adam; Fitzgerald, Michael; Robertson, Ian H.

    2008-01-01

    The present study examines a new alertness training strategy (Self-Alert Training, SAT) designed to explore the relationship between the top-down control processes governing arousal and sustained attention. In order to maximally target frontal control systems SAT combines a previously validated behavioural self-alerting technique [Robertson, I.…

  16. Protecting sensitive systems and data in an open agency

    NASA Technical Reports Server (NTRS)

    Hunt, Douglas B.; Tompkins, Frederick G.

    1987-01-01

    This paper focuses on the policy and definitional issues associated with providing adequate and reasonable levels of protection for sensitive systems and data in an agency whose basic charter mandates the open sharing of information and transfer of technology into the market economy. An information model based on current Federal regulatory issuances is presented. A scheme for determining sensitivity levels, based on a categorization taxonomy,is provided.

  17. Real time PPP approach with troposphere estimation using ultra rapid predicted products. Applications to GNSS in seismology in ALERTES-RIM system.

    NASA Astrophysics Data System (ADS)

    Cibeira Urtiaga, Ángel; Berrocoso, Manuel; Gárate, Jorge; Pazos, Antonio

    2016-04-01

    PPP approach has several advantages on other approaches focused on big precision real time applications. One of this advantages is, for instance, a less processing burden compared with double differences. Another particularity is the viability of working with one standalone receptor, without using a geodetic net nor reference stations. Nevertheless, the former has several disadvantages (e.g. several errors mitigated by double differences must be treated accordingly). Once working using the PPP approach for earthquake early warning systems, the troposfheric delay must be treated carefully, since it introduces errors in the final solution that make the accuracy decrease. In order to bring down this effect, we first work in a static way using ultra-rapid predicted IGS ephemerides to get a estimation of the troposphere we will use in a kinematic processing. This method if focused on improving the accuracy of the approach in near real time applications, and can be also combined with other strategies of filtering like sidereal filtering. It's viability in ALERTES-RIM early warning system is under study. For this, GIPSY-OASIS software from JPL is used.

  18. 77 FR 76434 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-28

    ... CFR Part 1001 Solicitation of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector... developing new OIG Special Fraud Alerts. DATES: To ensure consideration, public comments must be delivered to... the public on recommendations for developing new or revised safe harbors and Special Fraud...

  19. 78 FR 78807 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION: Notice of intent to develop... Social Security Act), as well as developing new OIG Special Fraud Alerts. DATES: To ensure consideration... the public on recommendations for developing new or revised safe harbors and Special Fraud...

  20. BEMFAM delivers AIDS alert.

    PubMed

    1993-05-01

    The Sociedade Civil Bem-Estar Familiar (BEMFAM) of Brazil developed a project using integrated communication strategies to alert prostitutes and their clients about the risks of contracting HIV. The project specifically promoted condom use and was conducted within the context of BEMFAM's Integrated Family Planning Program. Villa Mimoza, a prostitution zone in the Estacio neighborhood of Rio de Janeiro, was the site of the intervention. This neighborhood harbors 44 houses of prostitution where an estimated 500 female prostitutes receive clients. An agreement was reached with the Association of Prostitutes of the State of Rio de Janeiro whereby it would help mobilize local women, merchants, brothel owners, and clients. Initial needs were assessed by BEMFAM and AIDSCOM through questionnaires and focus groups. It was subsequently resolved that radio programs, counter displays of educational materials in brothels, and posters in brothel rooms would be the most effective channels through which to carry integrated, effective messages to the community. Final evaluation found a change in attitude and an awareness of the importance of measures to prevent AIDS along with a prevalent increase in condom use.

  1. 41 CFR 301-71.1 - What is the purpose of an agency travel accounting system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an agency travel accounting system? 301-71.1 Section 301-71.1 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES AGENCY RESPONSIBILITIES 71-AGENCY TRAVEL ACCOUNTABILITY REQUIREMENTS General § 301-71.1 What is the purpose of an agency...

  2. 41 CFR 301-71.1 - What is the purpose of an agency travel accounting system?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... an agency travel accounting system? 301-71.1 Section 301-71.1 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES AGENCY RESPONSIBILITIES 71-AGENCY TRAVEL ACCOUNTABILITY REQUIREMENTS General § 301-71.1 What is the purpose of an agency...

  3. 41 CFR 301-71.1 - What is the purpose of an agency travel accounting system?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... an agency travel accounting system? 301-71.1 Section 301-71.1 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES AGENCY RESPONSIBILITIES 71-AGENCY TRAVEL ACCOUNTABILITY REQUIREMENTS General § 301-71.1 What is the purpose of an agency...

  4. 41 CFR 301-71.1 - What is the purpose of an agency travel accounting system?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... agency travel accounting system? 301-71.1 Section 301-71.1 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES AGENCY RESPONSIBILITIES 71-AGENCY TRAVEL ACCOUNTABILITY REQUIREMENTS General § 301-71.1 What is the purpose of an agency travel...

  5. 41 CFR 301-71.1 - What is the purpose of an agency travel accounting system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... an agency travel accounting system? 301-71.1 Section 301-71.1 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES AGENCY RESPONSIBILITIES 71-AGENCY TRAVEL ACCOUNTABILITY REQUIREMENTS General § 301-71.1 What is the purpose of an agency...

  6. 20 CFR 658.410 - Establishment of State agency JS complaint system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Establishment of State agency JS complaint... Agency Js Complaint System § 658.410 Establishment of State agency JS complaint system. (a) Each State... State Administrator shall have overall responsibility for the operation of the State agency JS...

  7. Alcohol Alert: Genetics of Alcoholism

    MedlinePlus

    ... 84 Alcohol Alert Number 84 Print Version The Genetics of Alcoholism Why can some people have a ... to an increased risk of alcoholism. Cutting-Edge Genetic Research in Alcoholism Although researchers already have made ...

  8. Participatory design for drug-drug interaction alerts.

    PubMed

    Luna, Daniel; Otero, Carlos; Almerares, Alfredo; Stanziola, Enrique; Risk, Marcelo; González Bernaldo de Quirós, Fernán

    2015-01-01

    The utilization of decision support systems, in the point of care, to alert drug-drug interactions has been shown to improve quality of care. Still, the use of these systems has not been as expected, it is believed, because of the difficulties in their knowledge databases; errors in the generation of the alerts and the lack of a suitable design. This study expands on the development of alerts using participatory design techniques based on user centered design process. This work was undertaken in three stages (inquiry, participatory design and usability testing) it showed that the use of these techniques improves satisfaction, effectiveness and efficiency in an alert system for drug-drug interactions, a fact that was evident in specific situations such as the decrease of errors to meet the specified task, the time, the workload optimization and users overall satisfaction in the system.

  9. Provider acceptance of an automated electronic alert for acute kidney injury

    PubMed Central

    Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry

    2016-01-01

    Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598

  10. Validation of the BacT/ALERT(R) 3D System for Rapid Sterility Testing of Biopharmaceutical Samples.

    PubMed

    Jimenez, Luis; Rana, Narendra; Amalraj, Joseph; Walker, Kimberly; Travers, Kasey

    2012-01-01

    The BacT/ALERT® 3D system was validated to determine the sterility of different types of biopharmaceutical samples such as water for injection, unprocessed bulk, and finished bulk. The installation, operation, and performance qualification were completed and verified under good manufacturing practices. During the installation and operation validation stages, the functionality and security of the system and software were completed and verified. For the performance qualification, 11 microorganisms were evaluated, six compendial (Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus subtilis, Candida albicans, Aspergillus niger, Clostridium sporogenes), one representing the number one microbial species in sterile product recalls (Burkholderia cepacia), and four environmental isolates (Kocuria rhizophila, Staphylococcus haemolyticus, Methylobacterium radiotolerans, and Penicillium spp.). Nine of the microorganisms were spiked into three different types of biopharmaceutical samples by three different analysts on different days to ascertain the equivalence, ruggedness, sensitivity, time of detection, and repeatability. In all samples, the BacT/ALERT® exhibited equivalent or better detection than the standard test. With the exception of M. radiotolerans, all 11 microorganisms were detected within 2.5 days using the BacT/ALERT® system and the standard test. The detection times for M. radiotolerans in the three sample types averaged 5.77 days. The minimum detectable level of cells for all the microorganisms tested was found to be within 1 to 2 CFU. The system optimized sterility testing by the simultaneous on-line, non-destructive incubation and detection of microbial growth.

  11. Early post-treatment choroidal thickness to alert sunset glow fundus in patients with Vogt-Koyanagi-Harada disease treated with systemic corticosteroids

    PubMed Central

    Hirooka, Kiriko; Saito, Wataru; Namba, Kenichi; Mizuuchi, Kazuomi; Iwata, Daiju; Hashimoto, Yuki; Ishida, Susumu

    2017-01-01

    Purpose To determine if early post-treatment central choroidal thickness (CCT) changes can predict sunset glow fundus (SGF) development in patients with Vogt-Koyanagi-Harada (VKH) disease treated using systemic corticosteroids. Methods This retrospective case series included 39 eyes of 21 treatment-naïve patients with acute VKH disease who could be followed up for more than 12 months after systemic corticosteroid therapy. The eyes were divided into two groups according to whether SGF was present or absent at 12 months (9 eyes of 5 patients versus 30 eyes of 16 patients, respectively). Using enhanced depth imaging optical coherence tomography, CCT values were measured before treatment, then at 1 week and 1 and 3 months after treatment in both groups and compared between the two groups. Results Development of SGF was found 4–11 months after treatment. Mean post-treatment CCT decreased significantly at all examinations compared with baseline in both groups, along with resolution of serous retinal detachment. One week after treatment, mean CCT was significantly higher in eyes with SGF than in those without (P = 0.024). SGF was present at 12 months in 9 of 22 eyes with CCT values > 410 μm at 1 week after starting treatment, in contrast with none of 17 eyes with CCT ≤ 410 μm at this time (P = 0.003). Conclusions The current study suggested the potential validity of early post-treatment CCT as a feasible index to alert future progression to SGF in patients with VKH disease treated using systemic corticosteroids. PMID:28241069

  12. 20 CFR 658.410 - Establishment of State agency JS complaint system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 4 2012-04-01 2012-04-01 false Establishment of State agency JS complaint... System State Agency Js Complaint System § 658.410 Establishment of State agency JS complaint system. (a... JS complaint system. At the local office level, the local office manager shall be responsible for...

  13. 20 CFR 658.410 - Establishment of State agency JS complaint system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 4 2014-04-01 2014-04-01 false Establishment of State agency JS complaint... System State Agency Js Complaint System § 658.410 Establishment of State agency JS complaint system. (a... JS complaint system. At the local office level, the local office manager shall be responsible for...

  14. 20 CFR 658.410 - Establishment of State agency JS complaint system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 4 2013-04-01 2013-04-01 false Establishment of State agency JS complaint... System State Agency Js Complaint System § 658.410 Establishment of State agency JS complaint system. (a... JS complaint system. At the local office level, the local office manager shall be responsible for...

  15. Gaia Science Alerts: Early Validation Phase Data from Gaia

    NASA Astrophysics Data System (ADS)

    Walton, Nicholas; Hodgkin, Simon; van Leeuwen, Floor

    2015-08-01

    The ESA Gaia satellite launched Dec 2013, and after successful completion of its in orbit commissioning in July 2014, begun routine operations, with the aim to accurately measure the astrometric and astrophysical properties of more than a billion stars in our Milky Way.As a significant by product of its observational scanning law, where each point on the sky is observed multiple times (~80 revisits on average) over the nominal 5 year mission, Gaia has significant utility in detecting new transients, both flux (e.g. Supernovae, Flare stars) and positional (e.g. Asteroids).We will present the current status of the Gaia Photometric Science Alerts (PSA) system that has been developed within the Gaia DPAC. The PSA pipeline provides a quick look analysis of the daily data stream from Gaia, and identifies new photometric alerts, from analysis of the object photometric and the low resolution spectro-photometric data. Via a set of filters, those identified as astrophysical in nature, are published to the community. The information provided currently includes positional and flux information.The Gaia Alerts working group has organised a significant early stage followup campaign, providing access to a wide variety of followup facilities. These have been used to provide classification spectra of the Gaia alert candidates, with the early phase data confirming that the alerts issued are indeed largely astrophysical transients, with only a small contamination rate.The presentation will address the early phase issues that have been addressed in localising and classifying alerts in the early phase of Gaia observations (for instance, how lack of early knowledge of the sky as seen by Gaia was mitigated by reference to external image data), and how the alert rate published by the PSA will ramp up towards the end of 2015, with the availability of more Gaia sky data.Information concerning the Gaia alerts system can be found at http://gaia.ac.uk/selected-gaia-science-alerts

  16. 78 FR 6081 - Agency Information Collection Activities; Comment Request; National Student Loan Data System (NSLDS)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-29

    ... Agency Information Collection Activities; Comment Request; National Student Loan Data System (NSLDS) AGENCY: Federal Student Aid (FSA), Department of Education (ED). ACTION: Notice. SUMMARY: In accordance... notice will be considered public records. Title of Collection: National Student Loan Data System...

  17. 76 FR 78673 - New Agency Information Collection Activity Under OMB Review: Exercise Information System (EXIS)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-19

    ... SECURITY Transportation Security Administration New Agency Information Collection Activity Under OMB Review: Exercise Information System (EXIS) AGENCY: Transportation Security Administration, DHS. ACTION: 30-day... burden for the TSA Exercise Information System (EXIS). EXIS is a web portal designed to...

  18. The RELativistic Electron Alert System for Exploration (RELEASE): Scope, Verification and Validation Status, and Intended Future Use

    NASA Astrophysics Data System (ADS)

    Posner, A.; Rother, O.; Heber, B.; Mueller-Mellin, R.; Krause, A.

    2008-12-01

    The RELEASE method of short-term forecasting of the intensity of prompt solar energetic protons of hazardous energies (~40 MeV) with relativistic electrons has been developed. Electrons are well known to provide the first sign of a solar particle event in progress, approximately one our ahead of more dangerous protons. The forecasting of sudden intensity increases of protons from solar energetic particle events is relevant for in-situ and regional (e.g., Earth-moon system) radiation protection of humans on exploration missions. The method utilizes the speed advantage of electrons over up to 40 MeV protons and newly discovered correlations of inverse rise time and intensity between the two dominant particle species of solar eruptions. The effectiveness of this tool bases on the observed similarities in particle transport between the Sun and 1 AU. Electrons act as test particles by probing the ever- changing heliospheric transport conditions that act on the slower moving protons. In February 2008, the method has been implemented with near-real- time data of the COSTEP instrument onboard SOHO located at L1. Forecasting output is available live via the internet. The ongoing verification and validation activity so far has proven the robustness and reliability of the tool under quiet conditions with an extremely low false-alarm rate. Ongoing activities aimed at improving the method with archived COSTEP data over a full solar cycle will be presented.

  19. Integration of Airborne Aerosol Prediction Systems and Vegetation Phenology to Track Pollen for Asthma Alerts in Public Health Decision Support Systems

    NASA Technical Reports Server (NTRS)

    Luvall, Jeffrey C.; Sprigg, William A.; Huete, Alfredo; Pejanovic, Goran; Nickovic, Slobodan; Krapfl, Heide; Budge, Amy; Zelicoff, Alan; VandeWater, Peter K.; Levetin, Estelle; Losleben, Mark; Weltzin, Jake

    2009-01-01

    The residual signal indicates that the pollen event may influence the seasonal signal to an extent that would allow detection, given accurate QA filtering and BRDF corrections. MODIS daily reflectances increased during the pollen season. The DREAM model (PREAM) was successfully modified for use with pollen and may provide 24-36 hour running pollen forecasts. Publicly available pollen forecasts are linked to general weather patterns and roughly-known species phenologies. These are too coarse for timely health interventions. PREAM addresses this key data gap so that targeting intervention measures can be determined temporally and geospatially. The New Mexico Department of Health (NMDOH) as part of its Environmental Public Health Tracking Network (EPHTN) would use PREAM a tool for alerting the public in advance of pollen bursts to intervene and reduce the health impact on asthma populations at risk.

  20. Pilots' use of a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier operations. Volume 1: Methodology, summary and conclusions

    NASA Technical Reports Server (NTRS)

    Chappell, Sheryl L.; Billings, Charles E.; Scott, Barry C.; Tuttell, Robert J.; Olsen, M. Christine; Kozon, Thomas E.

    1989-01-01

    Pilots' use of and responses to a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier line operations are described in Volume 1. TCAS 2 monitors the positions of nearby aircraft by means of transponder interrogation, and it commands a climb or descent when conflicting aircraft are projected to reach an unsafe closest point-of-approach within 20 to 25 seconds. A different level of information about the location of other air traffic was presented to each of three groups of flight crews during their execution of eight simulated air carrier flights. A fourth group of pilots flew the same segments without TCAS 2 equipment. Traffic conflicts were generated at intervals during the flights; many of the conflict aircraft were visible to the flight crews. The TCAS equipment successfully ameliorated the seriousness of all conflicts; three of four non-TCAS crews had hazardous encounters. Response times to TCAS maneuver commands did not differ as a function of the amount of information provided, nor did response accuracy. Differences in flight experience did not appear to contribute to the small performance differences observed. Pilots used the displays of conflicting traffic to maneuver to avoid unseen traffic before maneuver advisories were issued by the TCAS equipment. The results indicate: (1) that pilots utilize TCAS effectively within the response times allocated by the TCAS logic, and (2) that TCAS 2 is an effective collision avoidance device. Volume II contains the appendices referenced in Volume I, providing details of the experiment and the results, and the text of two reports written in support of the program.

  1. Pilots' use of a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier operations. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Chappell, Sheryl L.; Billings, Charles E.; Scott, Barry C.; Tuttell, Robert J.; Olsen, M. Christine; Kozon, Thomas E.

    1989-01-01

    Pilots' use of and responses to a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier line operations are discribed in Volume 1. TCAS 2 monitors the positions of nearby aircraft by means of transponder interrogation, and it commands a climb or descent which conflicting aircraft are projected to reach an unsafe closest point-of-approach within 20 to 25 seconds. A different level of information about the location of other air traffic was presented to each of three groups of flight crews during their execution of eight simulated air carrier flights. A fourth group of pilots flew the same segments without TCAS 2 equipment. Traffic conflicts were generated at intervals during the flights; many of the conflict aircraft were visible to the flight crews. The TCAS equipment successfully ameliorated the seriousness of all conflicts; three of four non-TCAS crews had hazardous encounters. Response times to TCAS maneuver commands did not differ as a function of the amount of information provided, nor did response accuracy. Differences in flight experience did not appear to contribute to the small performance differences observed. Pilots used the displays of conflicting traffic to maneuver to avoid unseen traffic before maneuver advisories were issued by the TCAS equipment. The results indicate: (1) that pilots utilize TCAS effectively within the response times allocated by the TCAS logic, and (2) that TCAS 2 is an effective collision avoidance device. Volume 2 contains the appendices referenced in Volume 1, providing details of the experiment and the results, and the text of two reports written in support of the program.

  2. Two Years into Verification and Validation of the Relativistic Electron Alert System for Exploration (REleASE): An Update into Rising Solar Activity

    NASA Astrophysics Data System (ADS)

    Posner, A.; Rother, O. M.; Heber, B.; Müller-Mellin, R.; Lee, J.

    2010-12-01

    For the past two years, the REleASE method of short-term forecasting of the intensity of prompt solar energetic protons of hazardous energies (~40 MeV) with relativistic electrons has been implemented. Since February 2008, REleASE translates near-real-time electron data of the SOHO/COSTEP instrument from L1 into near-future proton fluxes. The live forecasting output is available online. Electrons are well known to provide the first sign of a solar particle event in progress, approximately one hour ahead of more dangerous protons. The forecasting of the sudden increase in intensity of protons from solar energetic particle events is relevant for radiation protection of humans on exploration missions. The method utilizes the speed advantage of electrons over up to 40 MeV protons and the correlations of inverse rise time and intensity between electrons and protons in solar particle events. The effectiveness of this tool is based on the observed similarities in particle transport between the Sun and 1 AU. Electrons act as test particles by probing the ever-changing heliospheric transport conditions that act on the slower moving protons. This presentation is the first detailed analysis of the REleASE output and shows its strengths and weaknesses through the early signs of solar activity in 2010. Electrons of a Solar Energetic Particle (SEP) event arrive at 1 AU and provide an early sign of more hazardous protons. The REleASE model would issue an alert at this time. Typically one hour into the event, the more hazardous ions from the SEP arrive at L1 or 1 AU along the same magnetic field lines as the electrons. This presentation analyzes the accuracy of this live warning system. The false/missed warning rate will be assessed and the accuracy of REleASE's forecast proton flux will be compared with measured fluxes.

  3. Performance Assessment of Network Intrusion-Alert Prediction

    DTIC Science & Technology

    2012-09-01

    suspicious ( Albin , 2011). However, if an attack is genuine, the system usually reports the attack only after it has happened since most attacks happen in...we extracted the alert log file to determine whether the tests are detected. Similar experiments were conducted in ( Albin , 2011), which identified...and report. Snort is not able to detect client-side attacks and pcap replay ( Albin , 2011). To reduce the number of “reset outside window” alerts, we

  4. Provider and pharmacist responses to warfarin drug–drug interaction alerts: a study of healthcare downstream of CPOE alerts

    PubMed Central

    Boro, Maureen S; Korman, Nancy E; Davoren, J Ben

    2011-01-01

    Objective To categorize the appropriateness of provider and pharmacist responses to warfarin critical drug–drug interaction (cDDI) alerts, assess responses and actions to the cDDI, and determine the occurrence of warfarin adverse drug events (ADE) after alerts. Design An 18-month, retrospective study of acute care admissions at a single Veterans Affairs medical center using computerized provider order entry (CPOE). Measurements Patients included had at least one warfarin cDDI alert. Chart reviews included baseline laboratory values and demographics, provider actions, patient outcomes, and associated factors, including other interacting medications and number of simultaneously processed alerts. Results 137 admissions were included (133 unique patients). Amiodarone, vitamin E in a multivitamin, sulfamethoxazole, and levothyroxine accounted for 75% of warfarin cDDI. Provider responses were clinically appropriate in 19.7% of admissions and pharmacist responses were appropriate in 9.5% of admissions. There were 50 ADE (36.6% of admissions) with warfarin; 80% were rated as having no or mild clinical effect. An increased number of non-critical alerts at the time of the reference cDDI alert was the only variable associated with an inappropriate provider response (p=0.01). Limitations This study was limited by being a retrospective review and the possibility of confounding variables, such as other interacting medications. Conclusion The large number of CPOE alerts may lead to inappropriate responses by providers and pharmacists. The high rate of ADE suggests a need for improved medication management systems for patients on warfarin. This study highlights the possibility of alert fatigue contributing to the high prevalence of inappropriate alert over-ride text responses. PMID:22037888

  5. Physicians’ response to computerised alerts for psychotropic drugs in older persons: a multilevel analysis of the associated alert, patient and physician characteristics

    PubMed Central

    Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali

    2012-01-01

    Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID

  6. Real-time monitoring of the human alertness level

    NASA Astrophysics Data System (ADS)

    Alvarez, Robin; del Pozo, Francisco; Hernando, Elena; Gomez, Eduardo; Jimenez, Antonio

    2003-04-01

    Many accidents are associated with a driver or machine operator's alertness level. Drowsiness often develops as a result of repetitive or monotonous tasks, uninterrupted by external stimuli. In order to enhance safety levels, it would be most desirable to monitor the individual's level of attention. In this work, changes in the power spectrum of the electroencephalographic signal (EEG) are associated with the subject's level of attention. This study reports on the initial research carried out in order to answer the following important questions: (i) Does a trend exist in the shape of the power spectrum, which will indicate the state of a subject's alertness state (drowsy, relaxed or alert)? (ii) What points on the cortex are most suitable to detect drowsiness and/or high alertness? (iii) What parameters in the power spectrum are most suitable to establish a workable alertness classification in human subjects? In this work, we answer these questions and combine power spectrum estimation and artificial neural network techniques to create a non-invasive and real - time system able to classify EEG into three levels of attention: High, Relaxed and Drowsiness. The classification is made every 10 seconds o more, a suitable time span for giving an alarm signal if the individual is with insufficient level of alertness. This time span is set by the user. The system was tested on twenty subjects. High and relaxed attention levels were measured in randomise hours of the day and drowsiness attention level was measured in the morning after one night of sleep deprivation.

  7. 78 FR 44622 - Agency Information Collection; Activity Under OMB Review; Confidential Close Call Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-24

    ... Research and Innovative Technology Administration Agency Information Collection; Activity Under OMB Review; Confidential Close Call Reporting System AGENCY: Research & Innovative Technology Administration (RITA), Bureau...: Demetra V. Collia, Bureau of Transportation Statistics, Research and Innovative Technology...

  8. Clinically Inconsequential Alerts: The Characteristics of Opioid Drug Alerts and Their Utility in Preventing Adverse Drug Events in the Emergency Department

    PubMed Central

    Genco, Emma K.; Forster, Jeri E.; Flaten, Hanna; Goss, Foster; Heard, Kennon J.; Hoppe, Jason; Monte, Andrew A.

    2016-01-01

    Study objective We examine the characteristics of clinical decision support alerts triggered when opioids are prescribed, including alert type, override rates, adverse drug events associated with opioids, and preventable adverse drug events. Methods This was a retrospective chart review study assessing adverse drug event occurrences for emergency department (ED) visits in a large urban academic medical center using a commercial electronic health record system with clinical decision support. Participants include those aged 18 to 89 years who arrived to the ED every fifth day between September 2012 and January 2013. The main outcome was characteristics of opioid drug alerts, including alert type, override rates, opioid-related adverse drug events, and adverse drug event preventability by clinical decision support. Results Opioid drug alerts were more likely to be overridden than nonopioid alerts (relative risk 1.35; 95% confidence interval [CI] 1.21 to 1.50). Opioid drug-allergy alerts were twice as likely to be overridden (relative risk 2.24; 95% CI 1.74 to 2.89). Opioid duplicate therapy alerts were 1.57 times as likely to be overridden (95% CI 1.30 to 1.89). Fourteen of 4,581 patients experienced an adverse drug event (0.31%; 95% CI 0.15% to 0.47%), and 8 were due to opioids (57.1%). None of the adverse drug events were preventable by clinical decision support. However, 46 alerts were accepted for 38 patients that averted a potential adverse drug event. Overall, 98.9% of opioid alerts did not result in an actual or averted adverse drug event, and 96.3% of opioid alerts were overridden. Conclusion Overridden opioid alerts did not result in adverse drug events. Clinical decision support successfully prevented adverse drug events at the expense of generating a large volume of inconsequential alerts. To prevent 1 adverse drug event, providers dealt with more than 123 unnecessary alerts. It is essential to refine clinical decision support alerting systems to eliminate

  9. Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation

    NASA Technical Reports Server (NTRS)

    Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James

    2015-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.

  10. [Computer alert and quality of care: application to the surveillance of hospital infections].

    PubMed

    Safran, E; Pittet, D; Borst, F; Thurler, G; Schulthess, P; Rebouillat, L; Lagana, M; Berney, J P; Berthoud, M; Copin, P

    1994-11-01

    The Centre Informatique of Geneva University Hospital is developing, in the environment of its hospital information system, DIOGENE, a computerized alert system for surveillance of hospital infections. This hospital information system is based on an open distributed architecture and a relational database system, and covers many medical applications. This environment allows the development of alerts useful for detecting patients at risk. The alerts offer to clinicians a mean to control their efficacy in patient care. They are a new application of telematics for surveillance in clinical epidemiology, and are a tool for quality assurance. Two examples of alerts established for hospital infection control activities are presented. The first alert systematically detects all cases of patients colonized by or infected with methicillin-resistant Staphylococcus aureus (MRSA). The second alert helps to organize prospective surveillance of bloodstream infections in order to identify some risk factors for infection and propose preventive measures.

  11. Reader Survey for INSECT ALERTS.

    ERIC Educational Resources Information Center

    Miller, Mason E.; Sauer, Richard J.

    To determine what might be done to improve "Insect Alerts," which is a newsletter that carries "information on insect biology, abundance, activity and interpretation of control need," put out through the Michigan Cooperative Extension Service 26 weeks a year, a survey was conducted. A mail questionnaire was sent to all 120 county extension…

  12. Career Alert Planning. Instructor Guide.

    ERIC Educational Resources Information Center

    Lankard, Bettina; And Others

    This instructor's guide to the Career Alert Planning (CAP) program is one of 14 components (see note) of a set of individualized materials designed to help participants find out about themselves and about the kind of work for which they are suited. In this program, participants become acquainted with occupations that are representative of 10 basic…

  13. Alerts and Notices (Devices)

    MedlinePlus

    ... Video Duodenoscopes: FDA Safety Communication 01/17/17 FUJIFILM Medical Systems, U.S.A., Inc. removes certain older ... de la FDA (en Español) 01/05/16 FUJIFILM Medical Systems, U.S.A., Inc. Validates Revised Reprocessing ...

  14. Three-Month Real-Time Dengue Forecast Models: An Early Warning System for Outbreak Alerts and Policy Decision Support in Singapore

    PubMed Central

    Shi, Yuan; Liu, Xu; Kok, Suet-Yheng; Rajarethinam, Jayanthi; Liang, Shaohong; Yap, Grace; Chong, Chee-Seng; Lee, Kim-Sung; Tan, Sharon S.Y.; Chin, Christopher Kuan Yew; Lo, Andrew; Kong, Waiming; Ng, Lee Ching; Cook, Alex R.

    2015-01-01

    Background: With its tropical rainforest climate, rapid urbanization, and changing demography and ecology, Singapore experiences endemic dengue; the last large outbreak in 2013 culminated in 22,170 cases. In the absence of a vaccine on the market, vector control is the key approach for prevention. Objectives: We sought to forecast the evolution of dengue epidemics in Singapore to provide early warning of outbreaks and to facilitate the public health response to moderate an impending outbreak. Methods: We developed a set of statistical models using least absolute shrinkage and selection operator (LASSO) methods to forecast the weekly incidence of dengue notifications over a 3-month time horizon. This forecasting tool used a variety of data streams and was updated weekly, including recent case data, meteorological data, vector surveillance data, and population-based national statistics. The forecasting methodology was compared with alternative approaches that have been proposed to model dengue case data (seasonal autoregressive integrated moving average and step-down linear regression) by fielding them on the 2013 dengue epidemic, the largest on record in Singapore. Results: Operationally useful forecasts were obtained at a 3-month lag using the LASSO-derived models. Based on the mean average percentage error, the LASSO approach provided more accurate forecasts than the other methods we assessed. We demonstrate its utility in Singapore’s dengue control program by providing a forecast of the 2013 outbreak for advance preparation of outbreak response. Conclusions: Statistical models built using machine learning methods such as LASSO have the potential to markedly improve forecasting techniques for recurrent infectious disease outbreaks such as dengue. Citation: Shi Y, Liu X, Kok SY, Rajarethinam J, Liang S, Yap G, Chong CS, Lee KS, Tan SS, Chin CK, Lo A, Kong W, Ng LC, Cook AR. 2016. Three-month real-time dengue forecast models: an early warning system for outbreak

  15. Successful ShakeAlert Performance for the Napa Quake

    NASA Astrophysics Data System (ADS)

    Allen, R. M.; Given, D. D.; Heaton, T. H.; Vidale, J. E.

    2014-12-01

    ShakeAlert, the demonstration earthquake early warning system, developed by the USGS, UC Berkeley, Caltech, ETH, and the University of Washington, functioned as expected for the August 24, 2014, M6.0 Napa earthquake. The first ShakeAlert was generated by the ElarmS algorithm 5.1 sec after the origin time of the earthquake, and 3.3 sec after the P-wave arrived at the closest station 6.5 km from the epicenter. This initial alert, based on P-wave triggers from four stations, estimated the magnitude to be 5.7. The warning was received at the UC Berkeley Seismological Laboratory 5 seconds before the S-wave and about 10 sec prior to the onset of the strongest shaking. ShakeAlert beta-testers across the San Francisco Bay Area simultaneously received the alert, including the San Francisco 911 center with 8 sec warning, and the BART train system. BART has implemented an automated train-stopping system that was activated (although no trains were running at 3:20 am). With the available network geometry and communications, the blind zone of the first alert had a radius of 16 km. The four stations that contributed to the first alert all encapsulate data into 1-second packets, but the latency in transmitting data to the processing center ranged from 0.27 to 2.62 seconds. If all the stations were to deliver data in 0.27 seconds, then the alert would have been available 2.3 sec sooner and the blind zone would be reduced to about 8 km. This would also mean that the city of Napa would have received about 1 second of warning. The magnitude estimate and event location were accurate from the initial alert onwards. The magnitude estimate did first increase to 5.8 and then dip to 5.4 2.6 sec after the initial alert, stayed at that level for 2 sec, and then returned to 5.7. The final magnitude estimate was 6.0, consistent with the ANSS catalog.

  16. The Relationship between Alertness and Executive Control

    ERIC Educational Resources Information Center

    Weinbach, Noam; Henik, Avishai

    2012-01-01

    The current study focuses on the relationship between alerting and executive attention. Previous studies reported an increased flanker congruency effect following alerting cues. In the first two experiments, we found that the alertness-congruency interaction did not exist for all executive tasks (it appeared for a flanker task but not for a Stroop…

  17. Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy

    DTIC Science & Technology

    2012-03-01

    element (or major branch of the tree) and its “ child ” features (offshoots of the major branch). Features may, in turn, have their own “ child ” features...aware of an ab- ducted child o Presidential An alert issued by the presi- dent of the United States  Source_of_Authority Entity that has...deputy officer arrives at the scene first and immediately sends the name, description, and photo of the abducted child along with descriptions of the

  18. OCD RADIO ALERT RECEIVERS.

    DTIC Science & Technology

    for methods of operating a radioalert system were established in conjunction with OCD representatives. Four types of operation were selected. Three...models each of these four receiver types were fabricated and tested. The total of 12 laboratory models were delivered to OCD . Test equipment...suitable for demonstrating the two most promising receiver types was also assembled, and delivered to OCD . A preliminary analysis of the cost of mass

  19. Kombucha--toxicity alert.

    PubMed

    The Kombucha mushroom, also known as Manchurian mushroom, is a mail-order product touted to lower blood pressure and raise T-cell counts. No controlled trials have been conducted to test these claims. Aspergillus, a mold that may grow on the Kombucha mushroom, attacks the brain and may be fatal to persons with weakened immune systems. Reported toxicity reactions have included stomach problems and yeast infections. Taking Kombucha in combination with other drugs may affect the drugs potency.

  20. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Agency performance appraisal system(s). 430.204 Section 430.204 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and...

  1. Bioterrorism: Health sector alertness

    PubMed Central

    Pinto, Violet N.

    2013-01-01

    The global events of the last two decades indicate that the threat of biological warfare is not a myth, but a harsh reality. The successive outbreaks caused by newly recognized and resurgent pathogens and the risk that high-consequence pathogens might be used as bioterrorism agents amply demonstrate the need to enhance capacity in clinical and public health management of highly infectious diseases. This review article provides a concise overview of bioterrorism, the agents used, and measures to counteract it, with a relevant note on India's current scenario of surveillance systems, laboratory response network, and the need for preparedness. PMID:23633831

  2. Agency problems of global budget system in Taiwan's National Health Insurance.

    PubMed

    Yan, Yu-Hua; Yang, Chen-Wei; Fang, Shih-Chieh

    2014-05-01

    The main purpose of this study was to investigate the agency problem presented by the global budget system followed by hospitals in Taiwan. In this study, we examine empirically the interaction between the principal: Bureau of National Health Insurance (BNHI) and agency: medical service providers (hospitals); we also describe actual medical service provider and hospital governance conditions from a agency theory perspective. This study identified a positive correlation between aversion to agency hazard (self-interest behavior, asymmetric information, and risk hedging) and agency problem risks (disregard of medical ethics, pursuit of extra-contract profit, disregard of professionalism, and cost orientation). Agency costs refer to BNHI auditing and monitoring expenditures used to prevent hospitals from deviating from NHI policy goals. This study also found agency costs negatively moderate the relationship between agency hazards and agency problems The main contribution of this study is its use of agency theory to clarify agency problems and several potential factors caused by the NHI system. This study also contributes to the field of health policy study by clarifying the nature and importance of agency problems in the health care sector.

  3. 28 CFR 802.29 - Exemption of the Pretrial Services Agency System.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Bail Agency Database (ABADABA) (CSOSA/PSA-1). (ii) Drug Test Management System (DTMS) (CSOSA/PSA-2... System. 802.29 Section 802.29 Judicial Administration COURT SERVICES AND OFFENDER SUPERVISION AGENCY FOR THE DISTRICT OF COLUMBIA DISCLOSURE OF RECORDS Exemption of Records Systems Under the Privacy...

  4. 28 CFR 802.29 - Exemption of the Pretrial Services Agency System.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Bail Agency Database (ABADABA) (CSOSA/PSA-1). (ii) Drug Test Management System (DTMS) (CSOSA/PSA-2... System. 802.29 Section 802.29 Judicial Administration COURT SERVICES AND OFFENDER SUPERVISION AGENCY FOR THE DISTRICT OF COLUMBIA DISCLOSURE OF RECORDS Exemption of Records Systems Under the Privacy...

  5. Using electronic health record alerts to provide public health situational awareness to clinicians.

    PubMed

    Lurio, Joseph; Morrison, Frances P; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations.

  6. Phasic Alertness Can Modulate Executive Control by Enhancing Global Processing of Visual Stimuli

    ERIC Educational Resources Information Center

    Weinbach, Noam; Henik, Avishai

    2011-01-01

    Researchers have suggested that the attention system is composed of several networks that have different functions. One of these networks is responsible for achieving and maintaining an alert state (alerting system), and another for selection and conflict resolution (executive control). There is growing interest in how these attentional networks…

  7. ANTARES: progress towards building a 'broker' of time-domain alerts

    NASA Astrophysics Data System (ADS)

    Saha, Abhijit; Wang, Zhe; Matheson, Thomas; Narayan, Gautham; Snodgrass, Richard; Kececioglu, John; Scheidegger, Carlos; Axelrod, Tim; Jenness, Tim; Ridgway, Stephen; Seaman, Robert; Taylor, Clark; Toeniskoetter, Jackson; Welch, Eric; Yang, Shuo; Zaidi, Tayeb

    2016-07-01

    The Arizona-NOAO Temporal Analysis and Response to Events System (ANTARES) is a joint effort of NOAO and the Department of Computer Science at the University of Arizona to build prototype software to process alerts from time-domain surveys, especially LSST, to identify those alerts that must be followed up immediately. Value is added by annotating incoming alerts with existing information from previous surveys and compilations across the electromagnetic spectrum and from the history of past alerts. Comparison against a knowledge repository of properties and features of known or predicted kinds of variable phenomena is used for categorization. The architecture and algorithms being employed are described.

  8. Frequency of tsunami alert bulletins in California

    NASA Astrophysics Data System (ADS)

    Dengler, L. A.

    2009-12-01

    To illustrate how likely a California coastal emergency manager is likely to encounter a tsunami alert bulletin, the last century of earthquake history is examined to see how many warnings, watches, or advisories would have been issued if today’s alert protocol were being used. Using the current protocol, eleven tsunami warnings would have been issued. Four of these - 1946, 1952, 1960, and 1964 - were caused by great earthquakes far away and would have resulted in all or nearly all of the California coast being placed in a warning. The sources were located 4.5 to16 hours travel time away from California. All of these events actually caused damage in California and the 1964 tsunami is ranked as a major disaster. The other seven warnings would have been issued for earthquakes in the magnitude 7 to 8 range located close to the US west coast. The 1906 “San Francisco” earthquake would have resulted in a warning for all of Northern California. The 1927 “Lompoc” earthquake would have caused a warning for Southern and Central California and the remaining warnings would have been limited to California’s North Coast. In contrast to far-field events, the travel time between the earthquake and the arrival of the first waves in these near field events is typically a half hour or less. These events did all produce small tsunamis, but none caused damage. Unlike the far-field events where the water level detection system can detect whether a significant wave has been produced before California is put into the warning classification, the near-field events don’t provide the luxury of verification before a warning is issued. Eight tsunami advisory bulletins would likely have been issued in the past century. Of these, six were from large earthquakes elsewhere in the Pacific and two were from North Coast earthquakes located further offshore than the warning events above. Two of these events, 1957 and 2006, caused significant damage in Crescent City. Thirteen earthquake

  9. Local IRBs vs. federal agencies: shifting dynamics, systems, and relationships.

    PubMed

    Klitzman, Robert L

    2012-07-01

    How IRBs relate to federal agencies, and the implications of these relationships, have received little, if any, systematic study. I interviewed 46 IRB chairs, directors, administrators, and members, contacting the leadership of 60 U.S. IRBs (every fourth one in the list of the top 240 institutions by NIH funding), interviewing IRB leaders from 34 (response rate=55%). IRBs describe complex direct and indirect relationships with federal agencies that affect IRBs through audits, guidance documents, and other communications, and can generate problems and challenges. Researchers often blame IRBs for frustrations, but IRBs often serve as the "local face" of federal regulations and agencies and are "stuck in the middle." These data have critical implications for policy, practice, and research.

  10. 76 FR 65206 - Agency Information Collection Activities: Small Vessel Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-20

    ... concerning the following information collection: Title: Small Vessel Reporting System. OMB Number: Will be... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities: Small Vessel Reporting System AGENCY: U.S. Customs and Border Protection (CBP), Department of Homeland Security....

  11. 78 FR 5477 - Agency Information Collection Activities: InfoPass System, No Form Number; Extension, Without...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-25

    ... SECURITY U.S. Citizenship and Immigration Services Agency Information Collection Activities: InfoPass... Collection. (2) Title of the Form/Collection: InfoPass System. (3) Agency form number, if any, and the.... The InfoPass system allows an applicant or petitioner to schedule an interview appointment with...

  12. Description of the AILS Alerting Algorithm

    NASA Technical Reports Server (NTRS)

    Samanant, Paul; Jackson, Mike

    2000-01-01

    This document provides a complete description of the Airborne Information for Lateral Spacing (AILS) alerting algorithms. The purpose of AILS is to provide separation assurance between aircraft during simultaneous approaches to closely spaced parallel runways. AILS will allow independent approaches to be flown in such situations where dependent approaches were previously required (typically under Instrument Meteorological Conditions (IMC)). This is achieved by providing multiple levels of alerting for pairs of aircraft that are in parallel approach situations. This document#s scope is comprehensive and covers everything from general overviews, definitions, and concepts down to algorithmic elements and equations. The entire algorithm is presented in complete and detailed pseudo-code format. This can be used by software programmers to program AILS into a software language. Additional supporting information is provided in the form of coordinate frame definitions, data requirements, calling requirements as well as all necessary pre-processing and post-processing requirements. This is important and required information for the implementation of AILS into an analysis, a simulation, or a real-time system.

  13. A Probability-Base Alerting Logic for Aircraft on Parallel Approach

    NASA Technical Reports Server (NTRS)

    Carpenter, Brenda D.; Kuchar, James K.

    1997-01-01

    This document discusses the development and evaluation of an airborne collision alerting logic for aircraft on closely-spaced approaches to parallel runways. A novel methodology is used when links alerts to collision probabilities: alerting thresholds are set such that when the probability of a collision exceeds an acceptable hazard level an alert is issued. The logic was designed to limit the hazard level to that estimated for the Precision Runway Monitoring system: one accident in every one thousand blunders which trigger alerts. When the aircraft were constrained to be coaltitude, evaluations of a two-dimensional version of the alerting logic show that the achieved hazard level is approximately one accident in every 250 blunders. Problematic scenarios have been identified and corrections to the logic can be made. The evaluations also show that over eighty percent of all unnecessary alerts were issued during scenarios in which the miss distance would have been less than 1000 ft, indicating that the alerts may have been justified. Also, no unnecessary alerts were generated during normal approaches.

  14. Dynamic malware containment under an epidemic model with alert

    NASA Astrophysics Data System (ADS)

    Zhang, Tianrui; Yang, Lu-Xing; Yang, Xiaofan; Wu, Yingbo; Tang, Yuan Yan

    2017-03-01

    Alerting at the early stage of malware invasion turns out to be an important complement to malware detection and elimination. This paper addresses the issue of how to dynamically contain the prevalence of malware at a lower cost, provided alerting is feasible. A controlled epidemic model with alert is established, and an optimal control problem based on the epidemic model is formulated. The optimality system for the optimal control problem is derived. The structure of an optimal control for the proposed optimal control problem is characterized under some conditions. Numerical examples show that the cost-efficiency of an optimal control strategy can be enhanced by adjusting the upper and lower bounds on admissible controls.

  15. A Description of the Environmental Protection Agency's In-House Library Systems.

    ERIC Educational Resources Information Center

    Thomas, Sarah M.; Needle, Lester P.

    The Environmental Protection Agency's (EPA) inhouse library systems fall into two principle categories: basic library inventory systems and literature retrieval systems. Currently, the library network supports three inventory systems: the journal system; the hard bound book system; and the circulation system. At the same time, five efforts are…

  16. Hotline Allegations Regarding Accounting for the Defense Information Systems Agency Working Capital Fund

    DTIC Science & Technology

    2007-11-02

    HOTLINE ALLEGATIONS REGARDING ACCOUNTING FOR THE DEFENSE INFORMATION SYSTEMS AGENCY WORKING CAPITAL FUND Report No. D-2001- 123 ...May 2001 Report Type N/A Dates Covered (from... to) ("DD MON YYYY") Title and Subtitle Hotline Allegations Regarding Accounting for the Defense...Room 801) Arlington, VA 22202-2884 Performing Organization Number(s) D-2001- 123 Sponsoring/Monitoring Agency Name(s) and Address(es) Monitoring Agency

  17. Managing Suspicious Activity Reporting Systems at Small Agency Police Departments

    DTIC Science & Technology

    2012-09-01

    61,571 53 Mountain view X 72,222 54 Napa X X 75,279 54 Suspicious Activity Reporting Population: 50,000–99,999 Agency SAR on...Montebello Napa Novato Perris Pittsburg Rancho Santa Margarita Redondo Beach Rosemead San Mateo Santa...Friday FBI’s LE Officers Killed and Assaulted(LEOKA) Napa , CA July 10-11, 2012; Tuesday - Wednesday Enhanced Threat and Risk Assessment

  18. Early Alert: A Report on Two Pilot Projects at Antelope Valley College.

    ERIC Educational Resources Information Center

    Lewallen, Willard Clark

    Two "early alert" pilot projects were established at Antelope Valley College, in California, to develop a follow-up system to ensure regular monitoring of student progress for early detection of academic difficulty. Two committees were established to explore and develop early alert strategies; the first focusing on basic skills courses…

  19. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... file into the format supported by mobile devices. (2) Reception. The CMS provider gateway must support... that each Participating Commercial Mobile Service provider is required to support and perform at...

  20. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... file into the format supported by mobile devices. (2) Reception. The CMS provider gateway must support... Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... that each Participating Commercial Mobile Service provider is required to support and perform at...

  1. 40 CFR 141.210 - Notice by primacy agency on behalf of the public water system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the public water system. 141.210 Section 141.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.210 Notice by primacy agency on behalf of the public...

  2. 40 CFR 141.210 - Notice by primacy agency on behalf of the public water system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the public water system. 141.210 Section 141.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.210 Notice by primacy agency on behalf of the public...

  3. 40 CFR 141.210 - Notice by primacy agency on behalf of the public water system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the public water system. 141.210 Section 141.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.210 Notice by primacy agency on behalf of the public...

  4. 40 CFR 141.210 - Notice by primacy agency on behalf of the public water system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the public water system. 141.210 Section 141.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.210 Notice by primacy agency on behalf of the public...

  5. 40 CFR 141.210 - Notice by primacy agency on behalf of the public water system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the public water system. 141.210 Section 141.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.210 Notice by primacy agency on behalf of the public...

  6. 78 FR 61378 - Agency Information Collection Activities: Small Vessel Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-03

    ... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities: Small Vessel Reporting System AGENCY: U.S. Customs and Border Protection, Department of Homeland Security. ACTION: 60-Day notice and request for comments; extension of an existing collection of information. SUMMARY: As part...

  7. 76 FR 82314 - Agency Information Collection Activities: Small Vessel Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-30

    ... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities: Small Vessel Reporting System AGENCY: U.S. Customs and Border Protection, Department of Homeland Security. ACTION: 30-Day notice and request for comments; Establishment of a new collection of information. SUMMARY: U.S....

  8. 78 FR 77139 - Agency Information Collection Activities: Small Vessel Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities: Small Vessel Reporting System AGENCY: U.S. Customs and Border Protection, Department of Homeland Security. ACTION: 30-Day.... Customs and Border Protection (CBP) of the Department of Homeland Security will be submitting...

  9. GMDSS False Alerts: A Persistent Problem for the Safety of Navigation at Sea

    NASA Astrophysics Data System (ADS)

    Tzannatos, E. S.

    2004-01-01

    GMDSS alerting was introduced in order to automate the call for search and rescue of a ship in distress, through the utilization of the most modern terrestrial and celestial communication systems. However, the GMDSS suffers from the inefficiencies associated with equipment design, operator competence and, most importantly, with those relevant to the equipment operator interface. The GMDSS inefficiencies are frequently manifested in the form of false alerts, which apart from using resources, degrade the overall effectiveness of the SAR operation. In this paper, the GMDSS post-full-implementation record of false alerts received by the Greek MRCC is presented and analyzed. The observed persistence of high incidence of false alerts dictates the need for the proposal of further measures to combat false alerts, to promote the intended mission of the system and to generally improve the safety of navigation at sea.

  10. NAPS as an Alertness Management Strategy

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Smith, Roy M.; Miller, Donna L.; Co, Elizabeth L.; Gregory, Kevin B.; Gander, Philippa H.; Lebacqz, J. Victor

    2001-01-01

    Today, 24-hour operations are necessary to meet the demands of our society and the requirements of our industrialized global economy. These around-the-clock demands pose unique physiological challenges for the humans who remain central to safe and productive operations. Optimal alertness and performance are critical factors that are increasingly challenged by unusual, extended, or changing work/rest schedules. Technological advancements and automated systems can exacerbate the challenges faced by the human factor in these environments. Shift work, transportation demands, and continuous operations engender sleep loss and circadian disruption. Both of these physiological factors can lead to increased sleepiness, decreased performance, and a reduced margin of safety. These factors can increase vulnerability to incidents and accidents in operational settings. The consequences can have both societal effects (e.g., major destructive accidents such as Three Mile Island, Exxon Valdez, Bhopal) and personal effects (e.g., an accident driving home after a night shift).

  11. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... digital selective call using a distress call format in bands used for terrestrial radio-communication or a... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert...

  12. Generalized Philosophy of Alerting with Applications for Parallel Approach Collision Prevention

    NASA Technical Reports Server (NTRS)

    Winder, Lee F.; Kuchar, James K.

    2000-01-01

    The goal of the research was to develop formal guidelines for the design of hazard avoidance systems. An alerting system is automation designed to reduce the likelihood of undesirable outcomes that are due to rare failures in a human-controlled system. It accomplishes this by monitoring the system, and issuing warning messages to the human operators when thought necessary to head off a problem. On examination of existing and recently proposed logics for alerting it appears that few commonly accepted principles guide the design process. Different logics intended to address the same hazards may take disparate forms and emphasize different aspects of performance, because each reflects the intuitive priorities of a different designer. Because performance must be satisfactory to all users of an alerting system (implying a universal meaning of acceptable performance) and not just one designer, a proposed logic often undergoes significant piecemeal modification before gamma general acceptance. This report is an initial attempt to clarify the common performance goals by which an alerting system is ultimately judged. A better understanding of these goals will hopefully allow designers to reach the final logic in a quicker, more direct and repeatable manner. As a case study, this report compares three alerting logics for collision prevention during independent approaches to parallel runways, and outlines a fourth alternative incorporating elements of the first three, but satisfying stated requirements. Three existing logics for parallel approach alerting are described. Each follows from different intuitive principles. The logics are presented as examples of three "philosophies" of alerting system design.

  13. Outlier detection for patient monitoring and alerting.

    PubMed

    Hauskrecht, Milos; Batal, Iyad; Valko, Michal; Visweswaran, Shyam; Cooper, Gregory F; Clermont, Gilles

    2013-02-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management decisions using past patient cases stored in electronic health records (EHRs). Our hypothesis is that a patient-management decision that is unusual with respect to past patient care may be due to an error and that it is worthwhile to generate an alert if such a decision is encountered. We evaluate this hypothesis using data obtained from EHRs of 4486 post-cardiac surgical patients and a subset of 222 alerts generated from the data. We base the evaluation on the opinions of a panel of experts. The results of the study support our hypothesis that the outlier-based alerting can lead to promising true alert rates. We observed true alert rates that ranged from 25% to 66% for a variety of patient-management actions, with 66% corresponding to the strongest outliers.

  14. Contribution to the top-down alert system associated with the upcoming French tsunami warning center (CENALT): tsunami hazard assessment along the French Mediterranean coast for the ALDES project

    NASA Astrophysics Data System (ADS)

    Loevenbruck, A.; Quentel, E.; Hebert, H.

    2011-12-01

    The catastrophic 2004 tsunami drew the international community's attention to tsunami risk in all basins where tsunamis occurred but no warning system exists. Consequently, under the coordination of UNESCO, France decided to create a regional center, called CENALT, for the north-east Atlantic and the western Mediterranean. This warning system, which should be operational by 2012, is set up by the CEA in collaboration with the SHOM and the CNRS. The French authorities are in charge of the top-down alert system including the local alert dissemination. In order to prepare the appropriate means and measures, they initiated the ALDES (Alerte Descendante) project to which the CEA also contributes. It aims at examining along the French Mediterranean coast the tsunami risk related to earthquakes and landslides. In addition to the evaluation at regional scale, it includes the detailed studies of 3 selected sites; the local alert system will be designed for one of them. In this project, our main task at CEA consists in assessing tsunami hazard related to seismic sources using numerical modeling. Tsunamis have already affected the west Mediterranean coast; however past events are too few and poorly documented to provide a suitable database. Thus, a synthesis of earthquakes representative of the tsunamigenic seismic activity and prone to induce the largest impact to the French coast is performed based on historical data, seismotectonics and first order models. The North Africa Margin, the Ligurian and the South Tyrrhenian Seas are considered as the main tsunamigenic zones. In order to forecast the most important plausible effects, the magnitudes are estimated by enhancing to some extent the largest known values. Our hazard estimation is based on the simulation of the induced tsunamis scenarios performed with the CEA code. Models of propagation in the basin and off the French coast allow evaluating the potential threat at regional scale in terms of sources location and

  15. Structural alerts for estimating the carcinogenicity of pesticides and biocides.

    PubMed

    Devillers, J; Mombelli, E; Samsera, R

    2011-03-01

    More than 20 years ago, Ashby and Tennant showed the interest of structural alerts for the prediction of the carcinogenicity of chemicals. These structural alerts are functional groups or structural features of various sizes that are linked to the level of carcinogenicity of chemicals. Since this pioneering work it has been possible to refine the alerts over time, as more experimental results have become available and additional mechanistic insights have been gained. To date, one of the most advanced lists of structural alerts for evaluating the carcinogenic potential of chemicals is the list proposed by Benigni and Bossa and that is implemented as a rule-based system in Toxtree and in the OECD QSAR Application Toolbox. In order to gain insight into the applicability of this system to the detection of potential carcinogens we screened about 200 pesticides and biocides showing a high structural diversity. Prediction results were compared with experimental data retrieved from an extensive bibliographical review. The prediction correctness was only equal to 60.14%. Attempts were made to analyse the sources of mispredictions.

  16. 75 FR 33898 - Agency Information Collection (VA Loan Electronic Reporting Interface (VALERI) System) Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-15

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF VETERANS AFFAIRS Agency Information Collection (VA Loan Electronic Reporting Interface (VALERI) System) Activity.... 2900-0021.'' SUPPLEMENTARY INFORMATION: Title: VA Loan Electronic Reporting Interface (VALERI)...

  17. PubMedAlertMe--standalone Windows-based PubMed SDI software application.

    PubMed

    Ma'ayan, Avi

    2008-05-01

    PubMedAlertMe is a Windows-based software system for automatically receiving e-mail alert messages about recent publications listed on PubMed. The e-mail messages contain links to newly available abstracts listed on PubMed describing publications that were selectively returned from a specified list of queries. Links are also provided to directly export citations to EndNote, and links are provided to directly forward articles to colleagues. The program is standalone. Thus, it does not require a remote mail server or user registration. PubMedAlertMe is free software, and can be downloaded from: http://amp.pharm.mssm.edu/PubMedAlertMe/PubMedAlertMe_setup.zip.

  18. 36 CFR 1236.26 - What actions must agencies take to maintain electronic information systems?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... take to maintain electronic information systems? 1236.26 Section 1236.26 Parks, Forests, and Public... electronic information systems? (a) Agencies must maintain inventories of electronic information systems and... electronic information systems that is adequate to: (1) Specify all technical characteristics necessary...

  19. 36 CFR 1236.26 - What actions must agencies take to maintain electronic information systems?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... take to maintain electronic information systems? 1236.26 Section 1236.26 Parks, Forests, and Public... electronic information systems? (a) Agencies must maintain inventories of electronic information systems and... electronic information systems that is adequate to: (1) Specify all technical characteristics necessary...

  20. 36 CFR 1236.26 - What actions must agencies take to maintain electronic information systems?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... take to maintain electronic information systems? 1236.26 Section 1236.26 Parks, Forests, and Public... electronic information systems? (a) Agencies must maintain inventories of electronic information systems and... electronic information systems that is adequate to: (1) Specify all technical characteristics necessary...

  1. 36 CFR 1236.26 - What actions must agencies take to maintain electronic information systems?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... take to maintain electronic information systems? 1236.26 Section 1236.26 Parks, Forests, and Public... electronic information systems? (a) Agencies must maintain inventories of electronic information systems and... electronic information systems that is adequate to: (1) Specify all technical characteristics necessary...

  2. 36 CFR 1236.26 - What actions must agencies take to maintain electronic information systems?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... take to maintain electronic information systems? 1236.26 Section 1236.26 Parks, Forests, and Public... electronic information systems? (a) Agencies must maintain inventories of electronic information systems and... electronic information systems that is adequate to: (1) Specify all technical characteristics necessary...

  3. User-centered design improves the usability of drug-drug interaction alerts: Experimental comparison of interfaces.

    PubMed

    Luna, Daniel R; Rizzato Lede, Daniel A; Otero, Carlos M; Risk, Marcelo R; González Bernaldo de Quirós, Fernán

    2017-02-01

    Clinical Decision Support Systems can alert health professionals about drug interactions when they prescribe medications. The Hospital Italiano de Buenos Aires in Argentina developed an electronic health record with drug-drug interaction alerts, using traditional software engineering techniques and requirements. Despite enhancing the drug-drug interaction knowledge database, the alert override rate of this system was very high. We redesigned the alert system using user-centered design (UCD) and participatory design techniques to enhance the drug-drug interaction alert interface. This paper describes the methodology of our UCD. We used crossover method with realistic, clinical vignettes to compare usability of the standard and new software versions in terms of efficiency, effectiveness, and user satisfaction. Our study showed that, compared to the traditional alert system, the UCD alert system was more efficient (alerts faster resolution), more effective (tasks completed with fewer errors), and more satisfying. These results indicate that UCD techniques that follow ISO 9241-210 can generate more usable alerts than traditional design.

  4. Insider Alert 1.0 Beta Version

    SciTech Connect

    Abbott, Robert

    2004-02-01

    Insider Alert 1.0 Beta Version supports interactive selection and graphical display of data generated by the Sandia Cognitive Framework, which simulates the examination of security data by experts of various specialties. Insider Alert also encompasses the configuration and data files input to the Cognitive Framework for this application. Insider Alert 1.0 Beta Version is a computer program for analyzing data indicative of possible espionage or improper handling of data by employees at Sandia National Laboratories (or other facilities with comparable policies and procedures for managing sensitive information) It prioritizes and displays information for review by security analysts.

  5. The Missile Defense Agency's space tracking and surveillance system

    NASA Astrophysics Data System (ADS)

    Watson, John; Zondervan, Keith

    2008-10-01

    The Ballistic Missile Defense System (BMDS) is a layered system incorporating elements in space. In addition to missile warning systems at geosynchronous altitudes, an operational BMDS will include a low Earth orbit (LEO) system-the Space Tracking and Surveillance System (STSS). It will use infrared sensing technologies synergistically with the Space Based Infrared Systems (SBIRS) and will provide a seamless adjunct to radars and sensors on the ground and in airborne platforms. STSS is being designed for a future operational capability to defend against evolving threats. STSS development is divided into phases, commencing with a two-satellite demonstration constellation scheduled for launch in 2008. The demonstration satellites will conduct a menu of tests and experiments to prove the system concept, including the ground segment. They will have limited operational capability within the integrated BMDS. Data from the demonstration satellites will be received and processed by the Missile Defense Space Experiment Center (MDSEC), a part of the Missile Defense Integration and Operations Center (MDIOC). MDA launched in 2007 into LEO a satellite (NFIRE) designed to make near-field multispectral measurements of boosting targets and to demonstrate laser communication, the latter in conjunction with the German satellite TerraSAR-X. The gimbaled, lightweight laser terminal has demonstrated on orbit a 5.5 gbps rate in both directions. The filter passbands of NFIRE are similar to the STSS demonstrator track sensor. While providing useful phenomenology during its time on orbit, NFIRE will also serve as a pathfinder in the development of STSS operations procedures.

  6. 76 FR 78738 - Agency Information Collection (Locality Pay System for Nurses and Other Health Care Personnel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-19

    ... AFFAIRS Agency Information Collection (Locality Pay System for Nurses and Other Health Care Personnel... INFORMATION: Title: Locality Pay System for Nurses and Other Health Care Personnel. OMB Control Number: 2900... determine locality pay system for certain health care personnel. VA medical facility Directors will use...

  7. Aiding the environment: the Australian Development Agency's experience of implementing an environmental management system

    SciTech Connect

    Keen, Meg . E-mail: meg.keen@anu.edu.au; Sullivan, Marjorie

    2005-08-15

    Aid agencies, like commercial businesses, are increasingly concerned with incorporating sound environmental management into their operations. Different approaches are being used to integrate sustainability into development assistance to ensure that environmental impacts are assessed and managed. One approach being used by AusAID, the Australian aid agency, is to implement an environmental management system (EMS) across program and project areas. This paper examines how AusAID has adapted the EMS approach to suit aid agency operations, and some of the lessons from the Australian experience.

  8. A Cost and Performance System (CAPS) in a Federal agency

    NASA Technical Reports Server (NTRS)

    Huseonia, W. F.; Penton, P. G.

    1994-01-01

    Cost and Performance System (CAPS) is an automated system used from the planning phase through implementation to analysis and documentation. Data is retrievable or available for analysis of cost versus performance anomalies. CAPS provides a uniform system across intra- and international elements. A common system is recommended throughout an entire cost or profit center. Data can be easily accumulated and aggregated into higher levels of tracking and reporting of cost and performance.The level and quality of performance or productivity is indicated in the CAPS model and its process. The CAPS model provides the necessary decision information and insight to the principal investigator/project engineer for a successful project management experience. CAPS provides all levels of management with the appropriate detailed level of data.

  9. An end-to-end architecture for distributing weather alerts to wireless handsets

    NASA Astrophysics Data System (ADS)

    Jones, Karen L.; Nguyen, Hung

    2005-06-01

    This paper describes the current National Weather Service's (NWS) system for providing weather alerts in the U.S. and will review how the existing end-to-end architecture is being leveraged to provide non-weather alerts, also known as "all-hazard alerts", to the general public. The paper then describes how a legacy system that transmits weather and all-hazard alerts can be extended via commercial wireless networks and protocols to reach 154 million Americans who carry cell phones. This approach uses commercial SATCOM and existing wireless carriers and services such as Short Messaging Service (SMS) for text and emerging Multimedia Messaging Service (MMS) protocol, which would allow for photos, maps, audio and video alerts to be sent to end users. This wireless broadcast alert delivery architecture is designed to be open and to embrace the National Weather Service's mandate to become an "" warning system for the general public. Examples of other public and private sector applications that require timely and intelligent push mechanisms using this alert dissemination approach are also given.

  10. Physician Alerts to Prevent Symptomatic Venous Thromboembolism in Hospitalized Patients

    PubMed Central

    Piazza, Gregory; Rosenbaum, Erin J.; Pendergast, William; Jacobson, Joseph O.; Pendleton, Robert C.; McLaren, Gordon D.; Elliott, C. Gregory; Stevens, Scott M.; Patton, William F.; Dabbagh, Ousama; Paterno, Marilyn D.; Catapane, Elaine; Li, Zhongzhen; Goldhaber, Samuel Z.

    2010-01-01

    Background Venous thromboembolism (VTE) prophylaxis remains underutilized among hospitalized patients. We designed and carried out a large multicenter randomized controlled trial to test the hypothesis that an alert from a hospital staff member to the Attending Physician will reduce the rate of symptomatic VTE among high-risk patients not receiving prophylaxis. Methods and Results We enrolled patients using a validated point score system to detect hospitalized patients at high risk for symptomatic VTE who were not receiving prophylaxis. 2,493 patients (82% on Medical Services) from 25 study sites were randomized to the intervention group (n=1,238), in which the responsible physician was alerted by another hospital staff member, versus the control group (n=1,255), in which no alert was issued. The primary end point was symptomatic, objectively confirmed VTE within 90 days. Patients whose physicians were alerted were more than twice as likely to receive VTE prophylaxis as controls (46.0% versus 20.6%, p<0.0001). The symptomatic VTE rate was lower in the intervention group (2.7% versus 3.4%; hazard ratio, 0.79; 95% confidence interval, 0.50 to 1.25), but the difference did not achieve statistical significance. The rate of major bleeding at 30 days in the alert group was similar to the control group (2.1% versus 2.3%, p=0.68). Conclusions A strategy of direct staff member to physician notification increases prophylaxis utilization and leads toward reducing the rate of symptomatic VTE in hospitalized patients. However, VTE prophylaxis continues to be underutilized even after physician notification, especially among Medical Service patients. PMID:19364975

  11. Vocational Rehabilitation. Trends and Issues Alert.

    ERIC Educational Resources Information Center

    Wonacott, Michael E.

    Vocational rehabilitation (VR) agencies are required partners in the one-stop system mandated by the Workforce Investment Act of 1998 (WIA). The following features have long characterized VR: the primary goal of integrated competitive employment for persons with disabilities; state flexibility in VR systems, approaches, and structures; case…

  12. Chemical Safety Alert: Safer Technology and Alternatives

    EPA Pesticide Factsheets

    This alert is intended to introduce safer technology concepts and general approaches, explains the concepts and principles, and gives brief examples of the integration of safer technologies into facility risk management activities.

  13. Commercial Mobile Alert Service (CMAS) Scenarios

    DTIC Science & Technology

    2012-05-01

    government officials to send targeted text alerts to the public via commercial mo- bile service providers (CMSPs). The SEI is developing integration...capabilities are operational within 30 minutes. Response measure Full operational capabilities within 30 minutes of incident Business goals...months and had its last exercise a month ago. Artifact The text of the alert Response The message is entered into the originating software

  14. Public Alerts for Hyper-Hazard Events

    NASA Astrophysics Data System (ADS)

    Woo, G.

    2011-12-01

    Hyper-hazard events pose an exceptional risk to threatened populations around the world. Because of the potentially grave number of casualties, special procedures need to be enacted to alert the public. This paper will consider the decision analysis associated with the provision of public alerts, and what training measures are required. Special focus will be on the issue of false alarms, and the social pyschology of population response to hazard warnings.

  15. Modulations among the alerting, orienting and executive control networks.

    PubMed

    Callejas, Alicia; Lupiàñez, Juan; Funes, María Jesús; Tudela, Pío

    2005-11-01

    This paper reports a series of experiments that were carried out in order to study the attentional system. Three networks make up this system, and each of them specializes in particular processes. The executive control network specializes in control processes, such as conflict resolution or detection of errors; the orienting network directs the processing system to the source of input and enhances its processing; the alerting network prepares the system for a fast response by maintaining an adequate level of activation in the cognitive system. Recently, Fan and collaborators [J Cogn Neurosci 14(3):340-347, 2002] designed a task to measure the efficiency of each network. We modified Fan's task to test the influences among the networks. We found that the executive control network is inhibited by the alerting network, whereas the orienting network raises the efficiency of the executive control network (Experiment 1). We also found that the alerting network influences the orienting network by speeding up its time course function (Experiment 2). Results were replicated in a third experiment, proving the effects to be stable over time, participants and experimental context, and to be potentially important as a tool for neuropsychological assessment.

  16. Distributed Cognition and Distributed Morality: Agency, Artifacts and Systems.

    PubMed

    Heersmink, Richard

    2017-04-01

    There are various philosophical approaches and theories describing the intimate relation people have to artifacts. In this paper, I explore the relation between two such theories, namely distributed cognition and distributed morality theory. I point out a number of similarities and differences in these views regarding the ontological status they attribute to artifacts and the larger systems they are part of. Having evaluated and compared these views, I continue by focussing on the way cognitive artifacts are used in moral practice. I specifically conceptualise how such artifacts (a) scaffold and extend moral reasoning and decision-making processes, (b) have a certain moral status which is contingent on their cognitive status, and (c) whether responsibility can be attributed to distributed systems. This paper is primarily written for those interested in the intersection of cognitive and moral theory as it relates to artifacts, but also for those independently interested in philosophical debates in extended and distributed cognition and ethics of (cognitive) technology.

  17. Alertness can be improved by an interaction between orienting attention and alerting attention in schizophrenia

    PubMed Central

    2011-01-01

    Background Attention is impaired in schizophrenia. Early attention components include orienting and alerting, as well as executive control networks. Previous studies have shown mainly executive control deficits, while few of them found orienting and alerting abnormalities. Here we explore the different attentive networks, their modulation and interactions in patients with schizophrenia. Methods Twenty-one schizophrenic patients (DSMIV), compared to 21 controls, performed a modified version of the Attention Network Task, in which an orienting paradigm (with valid, invalid and no cues) was combined with a flanker task (congruent/incongruent) and an alerting signal (tone/no tone), to assess orienting, executive control and alerting networks independently. Results Patients showed an abnormal alerting effect and slower overall reaction time compared to controls. Moreover, there was an interaction between orienting and alerting: patients are helped more than controls by the alerting signal in a valid orientation to solve the incongruent condition. Conclusion These results suggest that patients with schizophrenia have altered alerting abilities. However, the orienting and alerting cues interact to improve their attention performance in the resolution of conflict, creating possibilities for cognitive remediation strategies. PMID:21729299

  18. Individual alerting efficiency modulates time perception

    PubMed Central

    Liu, Peiduo; Yang, Wenjing; Yuan, Xiangyong; Bi, Cuihua; Chen, Antao; Huang, Xiting

    2015-01-01

    Time perception plays a fundamental role in human perceptual and motor activities, and can be influenced by various factors, such as selective attention and arousal. However, little is known about the influence of individual alerting efficiency on perceived duration. In this study, we explored this question by running two experiments. The Attentional Networks Test was used to evaluate individual differences in alerting efficiency in each experiment. Temporal bisection (Experiment 1) and time generalization task (Experiment 2) were used to explore the participants’ perception of duration. The results indicated that subjects in the high alerting efficiency group overestimated interval durations and estimated durations more accurately compared with subjects in the low alerting efficiency group. The two experiments showed that the sensitivity of time was not influenced by individual alerting efficiency. Based on previous studies and current findings, we infer that individual differences in alerting efficiency may influence time perception through modulating the latency of the attention-controlled switch and the speed of the peacemaker within the framework of the internal clock model. PMID:25904881

  19. Application of a Model for Improving the Training and Education System of a Federal Agency.

    ERIC Educational Resources Information Center

    Thomas, John W.

    The Far West Laboratory used a five-step instructional systems design (ISD) model to develop a nationwide training and educational curriculum and delivery system for the Federal Emergency Management Agency. Stages of the model involved defining a comprehensive set of objectives, defining a priority curriculum, assigning training strategies,…

  20. 78 FR 59099 - Agency Information Collection (VA Loan Electronic Reporting Interface (VALERI) System) Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF VETERANS AFFAIRS Agency Information Collection (VA Loan Electronic Reporting Interface (VALERI) System) Activity... Reporting Interface (VALERI) System. OMB Control Number: 2900-0021. Type of Review: Revision of a...

  1. Information Systems in Child, Youth, and Family Agencies: Planning, Implementation, and Service Enhancement.

    ERIC Educational Resources Information Center

    Grasso, Anthony J., Ed.; Epstein, Irwin, Ed.

    This book describes Boysville's 5-year effort to design, implement, and evaluate an agency-based computerized management information, program evaluation, and clinical decision-making system, BOMIS (Boysville Management Information System). The goal of BOMIS is the integration of the four intervention programs, through the collection, analysis,…

  2. Sounding the Alert: Designing an Effective Voice for Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Burkett, E. R.; Given, D. D.

    2015-12-01

    The USGS is working with partners to develop the ShakeAlert Earthquake Early Warning (EEW) system (http://pubs.usgs.gov/fs/2014/3083/) to protect life and property along the U.S. West Coast, where the highest national seismic hazard is concentrated. EEW sends an alert that shaking from an earthquake is on its way (in seconds to tens of seconds) to allow recipients or automated systems to take appropriate actions at their location to protect themselves and/or sensitive equipment. ShakeAlert is transitioning toward a production prototype phase in which test users might begin testing applications of the technology. While a subset of uses will be automated (e.g., opening fire house doors), other applications will alert individuals by radio or cellphone notifications and require behavioral decisions to protect themselves (e.g., "Drop, Cover, Hold On"). The project needs to select and move forward with a consistent alert sound to be widely and quickly recognized as an earthquake alert. In this study we combine EEW science and capabilities with an understanding of human behavior from the social and psychological sciences to provide insight toward the design of effective sounds to help best motivate proper action by alert recipients. We present a review of existing research and literature, compiled as considerations and recommendations for alert sound characteristics optimized for EEW. We do not yet address wording of an audible message about the earthquake (e.g., intensity and timing until arrival of shaking or possible actions), although it will be a future component to accompany the sound. We consider pitch(es), loudness, rhythm, tempo, duration, and harmony. Important behavioral responses to sound to take into account include that people respond to discordant sounds with anxiety, can be calmed by harmony and softness, and are innately alerted by loud and abrupt sounds, although levels high enough to be auditory stressors can negatively impact human judgment.

  3. Study of Integration Considerations for Wireless Emergency Alerts

    DTIC Science & Technology

    2014-02-01

    Valley, California • Department of Homeland Security Science and Technology Directorate, Washington, D.C. • EAS Committee, Wisconsin • National...Department of Homeland Security Science and Technology Directorate (DHS S&T).1 This report, Study of Integration Strategy Considerations for Wireless...system. As alerting technology evolves, and as EMA jurisdictions grow and change, the scale and need for coordination increas- es. The subsequent

  4. Impact of Homeland Security Alert level on calls to a law enforcement peer support hotline.

    PubMed

    Omer, Saad B; Barnett, Daniel J; Castellano, Cherie; Wierzba, Rachel K; Hiremath, Girish S; Balicer, Ran D; Everly, George S

    2007-01-01

    The Homeland Security Advisory System (HSAS) was established by the Department of Homeland Security to communicate the risk of a terrorist event. In order to explore the potential psychological impacts of HSAS we analyzed the effects of terror alerts on the law enforcement community. We used data from the New Jersey Cop 2 Cop crisis intervention hotline. Incidence Rate Ratios--interpreted as average relative increases in the daily number of calls to the Cop 2 Cop hotline during an increased alert period--were computed from Poisson models. The hotline received a total of 4,145 initial calls during the study period. The mean daily number of calls was higher during alert level elevation compared to prior 7 days (7.68 vs. 8.00). In the Poisson regression analysis, the Incidence Rate Ratios of number of calls received during elevated alert levels compared to the reference period of seven days preceding each change in alert were close to 1, with confidence intervals crossing 1 (i.e. not statistically significant) for all lag periods evaluated. This investigation, in the context of New Jersey law enforcement personnel, does not support the concern that elevating the alert status places undue stress upon alert recipients.

  5. A clinical data warehouse-based process for refining medication orders alerts.

    PubMed

    Boussadi, Abdelali; Caruba, Thibaut; Zapletal, Eric; Sabatier, Brigitte; Durieux, Pierre; Degoulet, Patrice

    2012-01-01

    The objective of this case report is to evaluate the use of a clinical data warehouse coupled with a clinical information system to test and refine alerts for medication orders control before they were fully implemented. A clinical decision rule refinement process was used to assess alerts. The criteria assessed were the frequencies of alerts for initial prescriptions of 10 medications whose dosage levels depend on renal function thresholds. In the first iteration of the process, the frequency of the 'exceeds maximum daily dose' alerts was 7.10% (617/8692), while that of the 'under dose' alerts was 3.14% (273/8692). Indicators were presented to the experts. During the different iterations of the process, 45 (16.07%) decision rules were removed, 105 (37.5%) were changed and 136 new rules were introduced. Extensive retrospective analysis of physicians' medication orders stored in a clinical data warehouse facilitates alert optimization toward the goal of maximizing the safety of the patient and minimizing overridden alerts.

  6. SC-228 Inclusion of DAA Warning Alert for TCAS Interoperability

    NASA Technical Reports Server (NTRS)

    Fern, Lisa

    2016-01-01

    This white paper summarizes NASA research results that have informed Special Committee 228 (SC-228) discussions and decisions regarding the inclusion of a warning-level alert within the detect and avoid (DAA) alerting structure for unmanned aircraft systems (UAS). For UAS, the removal of the pilot from onboard the aircraft has eliminated the ability of the ground-based pilot in command (PIC) to use out-the-window visual information to make judgments about a potential threat of a loss of well clear with another aircraft. As a result, the DAA traffic display will be the primary source of information that the PIC can use to execute the three primary well clear functions: 1) detect a potential loss of well clear, 2) determine a resolution maneuver, and 3) upload that maneuver to the aircraft via the ground control station (GCS). In addition, pilots are required to coordinate with air traffic control (ATC) prior to maneuvering off of their approved flight plan. In determining an appropriate resolution maneuver to avoid a loss of well clear, the PIC must decide both when and how to maneuver, and both the timeliness and the accuracy (i.e., correctness) of the maneuver are critical to reducing the likelihood and/or severity of a loss of well clear. Alerting information is one of three critical components of the DAA display, along with traffic information elements (e.g., relative heading, speed and altitude) and maneuver guidance. Alerting information and maneuver guidance, in particular, have been found to have a significant impact, both statistically and practically, on pilots' ability to avoid and minimize the severity of losses of well clear While all three display components are key to pilots performing the traffic avoidance task of remaining well clear, in general, alerting information provides crucial information about when a resolution maneuver is required while maneuver guidance assists the pilot in determining how best to maneuver. A fundamental task of the DAA

  7. The Swift Burst Alert Telescope

    NASA Astrophysics Data System (ADS)

    Parsons, A.; Barthelmy, S.; Barbier, L.; Gehrels, N.; Palmer, D.; Tueller, J.; Fenimore, E.; BAT Engineering Team

    2000-10-01

    The Swift Gamma Ray Burst MIDEX is a multiwavelength observatory scheduled to be launched in September 2003 to study gamma-ray bursts (GRBs) and their x-ray and optical afterglow emission. Swift will exploit these newly discovered GRB afterglow characteristics to make a comprehensive study of ~ 1000 GRBs and use the afterglow phenomenon as a tool for probing their source and evolution. Swift will also be able to use GRBs to probe the early Universe. The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Mission. BAT will observe and locate hundreds of bursts per year to better than 4 arc minutes accuracy. Using this prompt burst location information, Swift can slew quickly (within 20 - 70 s) to point on-board x-ray (XRT) and optical (UVOT) instrumentation at the burst for continued afterglow studies. The BAT instrument consists of a large (5200 cm2) hard x-ray detector plane positioned one meter away from an even larger (2.6 m2) coded aperture mask. The BAT detector plane consists of 128 CdZnTe semiconductor detector modules each containing 256 individual, planar 4 mm x 4 mm x 2 mm CdZnTe detectors that are read out by a pair of XA1 Application Specific Integrated Circuits (ASICs). The BAT mask will be constructed using 5 mm x 5 mm x 1 mm lead tiles attached to a self-supporting 0.4 g/cm2 substrate fabricated from Kevlar fiber/honeycomb materials. With 4 mm square focal plane detector elements and 5 mm square mask pixels, BAT will have angular resolution better than 22 arc minutes and will determine GRB source locations to ~ 4 arc minutes for bursts detected at 5 sigma or brighter. A full description of the BAT instrument and its capabilities will be presented along with results from performance tests of prototype detector modules.

  8. Ballistic Missile Defense System Transition and Transfer Process from Missile Defense Agency to the Army - Innovative or Dysfunctional?

    DTIC Science & Technology

    2010-04-14

    TRANSFER PROCESS FROM MISSILE DEFENSE AGENCY TO THE ARMY– INNOVATIVE OR DYSFUNCTIONAL? BY LIEUTENANT COLONEL SCOTT C. ARMSTRONG United States Army...5a. CONTRACT NUMBER Ballistic Missile Defense System Transition and Transfer Process from Missile Defense Agency to the Army – Innovative or...TRANSITION AND TRANSFER PROCESS FROM MISSILE DEFENSE AGENCY TO THE ARMY— INNOVATIVE OR DYSFUNCTIONAL? by Lieutenant Colonel Scott C. Armstrong

  9. Phasic alertness and residual switch costs in task switching.

    PubMed

    Schneider, Darryl W

    2017-02-01

    Residual switch costs are deficits in task-switching performance that occur despite considerable time to prepare for a task switch. In the present study, the author investigated whether increased phasic alertness modulates residual switch costs. In 2 experiments involving the task-cuing procedure, subjects performed numerical categorization tasks on target digits, with and without an alerting stimulus presented shortly before the target (alert and no-alert trials, respectively). Switch costs were obtained that decreased with a longer cue-target interval, indicating subjects engaged in preparation, but large residual switch costs remained. Alerting effects were obtained in the form of faster overall performance on alert than on no-alert trials, indicating the alerting stimuli increased phasic alertness. Critically, residual switch costs were similar on alert and no-alert trials in both experiments, unaffected by manipulations of alert type, alert availability, and alert-target interval. Implications of the results for understanding the relationship between phasic alertness and cognitive control in task switching are discussed. (PsycINFO Database Record

  10. 20 CFR 652.201 - What is the role of the State agency in the One-Stop delivery system?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... One-Stop delivery system? 652.201 Section 652.201 Employees' Benefits EMPLOYMENT AND TRAINING... Services in a One-Stop Delivery System Environment § 652.201 What is the role of the State agency in the One-Stop delivery system? (a) The role of the State agency in the One-Stop delivery system is...

  11. Subjective alertness rhythms in elderly people

    NASA Technical Reports Server (NTRS)

    Monk, T. H.; Buysse, D. J.; Reynolds, C. F. 3rd; Kupfer, D. J.; Houck, P. R.

    1996-01-01

    The aim of this study was to evaluate age-related changes in the circadian rhythm of subjective alertness and to explore the circadian mechanisms underlying such changes. Using a visual analogue scale (VAS) instrument, 25 older men and women (71 y and older; 15 female, 10 male) rated their subjective alertness about 7 times per day during 5 baseline days of temporal isolation during which habitual bedtimes and waketimes were enforced. Comparisons were made with 13 middle-aged men (37-52 y) experiencing the same protocol. Advancing age (particularly in the men) resulted in less rhythmic alertness patterns, as indicated by lower amplitudes and less reliability of fitted 24-h sinusoids. This appeared in spite of the absence of any reliable age-related diminution in circadian temperature rhythm amplitude, thus suggesting the effect was not due to SCN weakness per se, but to weakened transduction of SCN output. In a further experiment, involving 36 h of constant wakeful bedrest, differences in the amplitude of the alertness rhythm were observed between 9 older men (79 y+), 7 older women (79 y+), and 17 young controls (9 males, 8 females, 19-28 y) suggesting that with advancing age (particularly in men) there is less rhythmic input into subjective alertness from the endogenous circadian pacemaker. These results may explain some of the nocturnal insomnia and daytime hypersomnia that afflict many elderly people.

  12. Direct inoculation method using BacT/ALERT 3D and BD Phoenix System allows rapid and accurate identification and susceptibility testing for both Gram-positive cocci and Gram-negative rods in aerobic blood cultures.

    PubMed

    Yonetani, Shota; Okazaki, Mitsuhiro; Araki, Koji; Makino, Hiroshi; Fukugawa, Yoko; Okuyama, Takahiro; Ohnishi, Hiroaki; Watanabe, Takashi

    2012-06-01

    This study describes a direct inoculation method using the automated BacT/ALERT 3D and the BD Phoenix System in combination for identification and susceptibility testing of isolates from positive blood cultures. Organism identification and susceptibility results were compared with the conventional method for 211 positive aerobic blood cultures. Of 110 Gram-positive cocci (GPCs), 98 (89.1%) isolates were correctly identified to the species level. Of 101 Gram-negative rods (GNRs), 98 (97.0%) isolates were correctly identified to the species level. The overall categorical agreement in antimicrobial susceptibility testing among the 110 GPCs was 92.7%, with 0.04% very major and 0.7% major error rates. The overall categorical agreement among 78 isolates of enterobacteria and 23 isolates of nonfermenters in GNRs was 99.5% and 91.1%, respectively, with no major errors identified. We conclude that, compared with previously reported direct inoculation methods, our method is superior in identification and susceptibility testing of GPCs.

  13. Comparative evaluation of the role of single and multiple blood specimens in the outcome of blood cultures using BacT/ALERT 3D (automated) blood culture system in a tertiary care hospital

    PubMed Central

    Elantamilan, D.; Lyngdoh, Valarie Wihiwot; Khyriem, Annie B.; Rajbongshi, Jyotismita; Bora, Ishani; Devi, Surbala Thingujam; Bhattacharyya, Prithwis; Barman, Himesh

    2016-01-01

    Introduction: Bloodstream infection (BSI) is a leading cause of mortality in critically ill patients. The mortality directly attributable to BSI has been estimated to be around 16% and 40% in general hospital population and Intensive Care Unit (ICU) population, respectively. The detection rate of these infections increases with the number of blood samples obtained for culture. The newer continuous monitoring automated blood culture systems with enhanced culture media show increased yield and sensitivity. Hence, we aimed at studying the role of single and multiple blood specimens from different sites at the same time in the outcome of automated blood culture system. Materials and Methods and Results: A total of 1054 blood culture sets were analyzed over 1 year, the sensitivity of one, two, and three samples in a set was found to be 85.67%, 96.59%, and 100%, respectively, which showed a statistically significant difference (P < 0.0001). Similar findings were seen in few more studies, however, among individual organisms in contrast to other studies, the isolation rates of Gram-positive bacteria were less than that of Gram-negative Bacilli with one (or first) sample in a blood culture set. In our study, despite using BacT/ALERT three-dimensional continuous culture monitoring system with FAN plus culture bottles, 15% of positive cultures would have been missed if only a single sample was collected in a blood culture set. Conclusion: The variables like the volume of blood and number of samples collected from different sites still play a major role in the outcome of these automated blood culture systems. PMID:27688629

  14. Environmental Media Systems: Innovations at the U.S. Environmental Protection Agency's National Exposure Research Laboratory

    ERIC Educational Resources Information Center

    Costelloe-Kuehn, Brandon

    2012-01-01

    This multi-sited ethnography analyzes challenges and opportunities in the design and development of digital media systems in the Office of Research and Development (ORD) at the United States Environmental Protection Agency (EPA). Drawing heavily from interviews conducted over the course of three years, primarily with scientists at the ORD's…

  15. 78 FR 64064 - Agency Information Collection (Principles of Excellence Complaint System Intake) Activity Under...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... AFFAIRS Agency Information Collection (Principles of Excellence Complaint System Intake) Activity Under... collection of information abstracted below to the Office of Management and Budget (OMB) for review and....Regulations.gov , or to Office of Information and Regulatory Affairs, Office of Management and Budget,...

  16. 77 FR 52110 - Agency Response to Public Comments of Safety Measurement System Changes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ... the vehicle is being driven (e.g. improper lane change, speeding). Further, the Vehicle Maintenance... System Changes AGENCY: Federal Motor Carrier Safety Administration, DOT. ACTION: Notice; response to comments. SUMMARY: The Federal Motor Carrier Safety Administration (FMCSA) announces changes to the...

  17. 5 CFR 1330.405 - Procedures for certifying agency appraisal systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... reporting requirements in paragraph (g) of this section; and (ii) Based on those annual reports, OPM... performance appraisal periods. (g) Annual reporting requirement. Agencies with certified appraisal systems... applicable, of senior employees to ensure that annual summary ratings or ratings of record are...

  18. The state agency experience (evaluation/selection of hardware for automated, geo-based information systems)

    NASA Technical Reports Server (NTRS)

    Campbell, L. F., Jr.

    1981-01-01

    The purpose and format of a panel session that addressed the procedures by which the hardware components of geographic information systems are evaluated and selected are described. State agencies from Alaska, Colorado, Montana, and Washington were represented and the topic was discussed within the general context of information requirements in land management decision making.

  19. 20 CFR 658.410 - Establishment of State agency JS complaint system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the JS complaint system. (c)(1) State agencies shall ensure that centralized control procedures are... Administrator of the local or State office taking the complaint shall ensure that a central complaint log is.... (Approved by the Office of Management and Budget under control number 1205-0039) (Pub. L. No. 96-511,...

  20. 78 FR 53196 - Agency Information Collection (Principles of Excellence Complaint System Intake); Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... public comment in response to the notice. VA published an emergency notice the Principles of Excellence... AFFAIRS Agency Information Collection (Principles of Excellence Complaint System Intake); Comment Request... Veterans Benefits Administration (VBA) is announcing an opportunity for public comment on the...

  1. 77 FR 65898 - Agency Information Collection Activities: InfoPass System, No Form Number; Extension, Without...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-31

    ... SECURITY U.S. Citizenship and Immigration Services Agency Information Collection Activities: InfoPass...: Extension, Without Change, of a Currently Approved Collection. (2) Title of the Form/Collection: InfoPass... as a brief abstract: Primary: Individuals or households. The InfoPass system allows an applicant...

  2. Case Management Agency Systems of Administering Long-Term Care: Evidence from the Channeling Demonstration.

    ERIC Educational Resources Information Center

    Kemper, Peter

    1990-01-01

    Examines what was learned from channeling demonstration about potential of case management agency systems for administering home care benefits. Considers both advantages (substitution of lower cost for higher cost services, negotiation of lower prices for services, quality assurance) and disadvantages (difficulty controlling participation rates,…

  3. 75 FR 25319 - Agency Information Collection (Survey of Satisfaction With the Disability Evaluation System (DES...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... AFFAIRS Agency Information Collection (Survey of Satisfaction With the Disability Evaluation System (DES... submit the collection of information abstracted below to the Office of Management and Budget (OMB) for review and comment. The PRA submission describes the nature of the information collection and...

  4. CISN ShakeAlert: Using early warnings for earthquakes in California

    NASA Astrophysics Data System (ADS)

    Hellweg, M.; Vinci, M.; CISN-EEW Project Team

    2011-12-01

    As part of a USGS-funded project, the California Integrated Seismic Network (CISN) is now implementing and testing a prototype, end-to-end system for earthquake early warning, the ShakeAlert system. Having an alert of shaking just before it starts can improve resilience if the recipient of the alert has developed plans for responding to it and acts on them. We are working with a suite of perspective users from critical industries and institutions throughout California, such as the Bay Area Rapid Transit District, to identify information necessary for ShakeAlert users, as well as delivery mechanisms, procedures and products. At the same time, we will support their efforts to determine and implement appropriate responses to alerts of expected earthquake shaking, and to assess possible uses and especially benefits to themselves and to society. Thus, a detailed introduction to the CISN ShakeAlert system is an integral part of our interaction with the users, as are regular opportunities for feedback and support. In a final workshop, users will be surveyed for evaluations of perspective uses for early warning in their organizations as well as expected improvements in their response to earthquakes due to the early warning and their expected savings in terms of lives, damage and resilience.

  5. Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

    NASA Technical Reports Server (NTRS)

    Monacos, Steve P. (Inventor); Panangadan, Anand V. (Inventor)

    2015-01-01

    A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

  6. Flight controller alertness and performance during spaceflight shiftwork operations.

    PubMed

    Kelly, S M; Rosekind, M R; Dinges, D F; Miller, D L; Gillen, K A; Gregory, K B; Aguilar, R D; Smith, R M

    1998-09-01

    Decreased alertness and performance associated with fatigue, sleep loss, and circadian disruption are issues faced by a diverse range of shiftwork operations personnel. During Space Transportation System (STS) operations, Mission Operations Directorate (MOD) personnel provide 24-hr. coverage of critical tasks. A joint NASA Johnson Space Center and NASA Ames Research Center project was undertaken to examine these issues in flight controllers during MOD shiftwork operations. An initial operational test of procedures and measures was conducted during the STS-53 mission in December 1992. The study measures included a Background Questionnaire, a subjective daily logbook completed on a 24-hour basis (to report sleep patterns, work periods, etc.), and an 8 minute performance and mood test battery administered at the beginning, middle, and end of each shift period. Seventeen flight controllers representing the 3 Orbit shifts participated. The initial results clearly support the need for further data collection during other STS missions to document baseline levels of alertness and performance during MOD shiftwork operations. Countermeasure strategies specific to the MOD environment are being developed to minimize the adverse effects of fatigue, sleep loss, and circadian disruption engendered by shiftwork operations. These issues are especially pertinent for the night shift operations and the acute phase advance required for the transition of day shift personnel into the night for shuttle launch. Implementation and evaluation of the countermeasure strategies to maximize alertness and performance is planned. As STS missions extend to further EDO (extended duration orbiters), and timelines and planning for 24-hour Space Station operations continue, alertness and performance issues related to sleep and circadian disruption will remain highly relevant in the MOD environment.

  7. 50 CFR 80.81 - What must an agency submit when applying for a comprehensive-management-system grant?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of the agency's comprehensive management system including inventory, strategic plan, operational plan... for a comprehensive-management-system grant? 80.81 Section 80.81 Wildlife and Fisheries UNITED STATES... when applying for a comprehensive-management-system grant? A State fish and wildlife agency must...

  8. 50 CFR 80.81 - What must an agency submit when applying for a comprehensive-management-system grant?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of the agency's comprehensive management system including inventory, strategic plan, operational plan... for a comprehensive-management-system grant? 80.81 Section 80.81 Wildlife and Fisheries UNITED STATES... when applying for a comprehensive-management-system grant? A State fish and wildlife agency must...

  9. 50 CFR 80.81 - What must an agency submit when applying for a comprehensive-management-system grant?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of the agency's comprehensive management system including inventory, strategic plan, operational plan... for a comprehensive-management-system grant? 80.81 Section 80.81 Wildlife and Fisheries UNITED STATES... when applying for a comprehensive-management-system grant? A State fish and wildlife agency must...

  10. The health system consequences of agency nursing and moonlighting in South Africa.

    PubMed

    Rispel, Laetitia C; Blaauw, Duane

    2015-01-01

    Background Worldwide, there is an increased reliance on casual staff in the health sector. Recent policy attention in South Africa has focused on the interrelated challenges of agency nursing and moonlighting in the health sector. Objective This paper examines the potential health system consequences of agency nursing and moonlighting among South African nurses. Methods During 2010, a cluster random sample of 80 hospitals was selected in four South African provinces. On the survey day, all nurses providing clinical care completed a self-administered questionnaire after giving informed consent. The questionnaire obtained information on socio-demographics, involvement in agency nursing and moonlighting, and self-reported indicators of potential health system consequences of agency nursing and moonlighting. A weighted analysis was done using STATA(®) 13. Results In the survey, 40.7% of nurses reported moonlighting or working for an agency in the preceding year. Of all participants, 51.5% reported feeling too tired to work, 11.5% paid less attention to nursing work on duty, and 10.9% took sick leave when not actually sick in the preceding year. Among the moonlighters, 11.9% had taken vacation leave to do agency work or moonlighting, and 9.8% reported conflicting schedules between their primary and secondary jobs. In the bivariate analysis, moonlighting nurses were significantly more likely than non-moonlighters to take sick leave when not sick (p=0.011) and to pay less attention to nursing work on duty (p=0.035). However, in a multiple logistic regression analysis, the differences between moonlighters and non-moonlighters did not remain statistically significant after adjusting for other socio-demographic variables. Conclusion Although moonlighting did not emerge as a statistically significant predictor, the reported health system consequences are serious. A combination of strong nursing leadership, effective management, and consultation with and buy-in from front

  11. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... distress message format, which is relayed through space stations. (b) The distress alert must be sent... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... authority of the person responsible for the ship, aircraft or other vehicle carrying the mobile station...

  12. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... distress message format, which is relayed through space stations. (b) The distress alert must be sent... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... authority of the person responsible for the ship, aircraft or other vehicle carrying the mobile station...

  13. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... distress message format, which is relayed through space stations. (b) The distress alert must be sent... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... authority of the person responsible for the ship, aircraft or other vehicle carrying the mobile station...

  14. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... distress message format, which is relayed through space stations. (b) The distress alert must be sent... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... authority of the person responsible for the ship, aircraft or other vehicle carrying the mobile station...

  15. Self-Regulation: Calm, Alert, and Learning

    ERIC Educational Resources Information Center

    Shanker, Stuart

    2010-01-01

    There is a growing awareness among developmental scientists that the better a child can self-regulate, the better she can rise to the challenge of mastering ever more complex skills and concepts. In the simplest terms, self-regulation can be defined as the ability to stay calmly focused and alert, which often involves--but cannot be reduced…

  16. Assessment in Education. IBE Special Alert

    ERIC Educational Resources Information Center

    UNESCO International Bureau of Education, 2014

    2014-01-01

    As another year is approaching, the time seems appropriate to look back and reflect on all the things that have been done, and more importantly learned during 2014. Along the same lines, and in order to offer further food for thought, the IBE is happy to share with you its latest Thematic alert on the topic of assessment in education. More…

  17. Innovative Software Tools Measure Behavioral Alertness

    NASA Technical Reports Server (NTRS)

    2014-01-01

    To monitor astronaut behavioral alertness in space, Johnson Space Center awarded Philadelphia-based Pulsar Informatics Inc. SBIR funding to develop software to be used onboard the International Space Station. Now used by the government and private companies, the technology has increased revenues for the firm by an average of 75 percent every year.

  18. Alerting or Somnogenic Light: Pick Your Color

    PubMed Central

    Bourgin, Patrice; Hubbard, Jeffrey

    2016-01-01

    In mammals, light exerts pervasive effects on physiology and behavior in two ways: indirectly through clock synchronization and the phase adjustment of circadian rhythms, and directly through the promotion of alertness and sleep, respectively, in diurnal and nocturnal species. A recent report by Pilorz and colleagues describes an even more complex role for the acute effects of light. In mice, blue light acutely causes behavioral arousal, whereas green wavelengths promote sleep. These opposing effects are mediated by melanopsin-based phototransduction through different neural pathways. These findings reconcile nocturnal and diurnal species through a common alerting response to blue light. One can hypothesize that the opposite responses to natural polychromatic light in night- or day-active animals may reflect higher sensitivity of nocturnal species to green, and diurnals to blue wavelengths, resulting in hypnogenic and alerting effects, respectively. Additional questions remain to be clarified. How do different light wavelengths affect other behaviors such as mood and cognition? How do those results apply to humans? How does light pose either a risk or benefit, depending on whether one needs to be asleep or alert? Indeed, in addition to timing, luminance levels, and light exposure duration, these findings stress the need to understand how best to adapt the color spectrum of light to our needs and to take this into account for the design of daily lighting concepts—a key challenge for today’s society, especially with the emergence of LED light technology. PMID:27525420

  19. Project ALERT. Workplace Education. External Evaluators Reports.

    ERIC Educational Resources Information Center

    Philippi, Jorie W.; Mikulecky, Larry; Lloyd, Paul

    This document contains four evaluations of Project ALERT (Adult Literacy Enhanced & Redefined through Training), a workplace literacy partnership of Wayne State University, the Detroit Public Schools, and several city organizations, unions, and manufacturers in the automobile industry that was formed to meet employees' job-specific basic skills…

  20. CEI-PEA Alert, Summer 2006

    ERIC Educational Resources Information Center

    Center for Educational Innovation - Public Education Association, 2006

    2006-01-01

    The "CEI-PEA Alert" is an advocacy newsletter that deals with topics of interest to all concerned with the New York City public schools. This issue includes: (1) Practical Skills & High Academic Standards: Career Technical Education; (2) Parents: Help Your Children Gain "Soft Skills" for the Workforce; (3) Culinary Arts…

  1. Feature Selection Using Information Gain for Improved Structural-Based Alert Correlation.

    PubMed

    Alhaj, Taqwa Ahmed; Siraj, Maheyzah Md; Zainal, Anazida; Elshoush, Huwaida Tagelsir; Elhaj, Fatin

    2016-01-01

    Grouping and clustering alerts for intrusion detection based on the similarity of features is referred to as structurally base alert correlation and can discover a list of attack steps. Previous researchers selected different features and data sources manually based on their knowledge and experience, which lead to the less accurate identification of attack steps and inconsistent performance of clustering accuracy. Furthermore, the existing alert correlation systems deal with a huge amount of data that contains null values, incomplete information, and irrelevant features causing the analysis of the alerts to be tedious, time-consuming and error-prone. Therefore, this paper focuses on selecting accurate and significant features of alerts that are appropriate to represent the attack steps, thus, enhancing the structural-based alert correlation model. A two-tier feature selection method is proposed to obtain the significant features. The first tier aims at ranking the subset of features based on high information gain entropy in decreasing order. The‏ second tier extends additional features with a better discriminative ability than the initially ranked features. Performance analysis results show the significance of the selected features in terms of the clustering accuracy using 2000 DARPA intrusion detection scenario-specific dataset.

  2. Feature Selection Using Information Gain for Improved Structural-Based Alert Correlation

    PubMed Central

    Siraj, Maheyzah Md; Zainal, Anazida; Elshoush, Huwaida Tagelsir; Elhaj, Fatin

    2016-01-01

    Grouping and clustering alerts for intrusion detection based on the similarity of features is referred to as structurally base alert correlation and can discover a list of attack steps. Previous researchers selected different features and data sources manually based on their knowledge and experience, which lead to the less accurate identification of attack steps and inconsistent performance of clustering accuracy. Furthermore, the existing alert correlation systems deal with a huge amount of data that contains null values, incomplete information, and irrelevant features causing the analysis of the alerts to be tedious, time-consuming and error-prone. Therefore, this paper focuses on selecting accurate and significant features of alerts that are appropriate to represent the attack steps, thus, enhancing the structural-based alert correlation model. A two-tier feature selection method is proposed to obtain the significant features. The first tier aims at ranking the subset of features based on high information gain entropy in decreasing order. The‏ second tier extends additional features with a better discriminative ability than the initially ranked features. Performance analysis results show the significance of the selected features in terms of the clustering accuracy using 2000 DARPA intrusion detection scenario-specific dataset. PMID:27893821

  3. Using rainfall thresholds and ensemble precipitation forecasts to issue and improve urban inundation alerts

    NASA Astrophysics Data System (ADS)

    Yang, Tsun-Hua; Hwang, Gong-Do; Tsai, Chin-Cheng; Ho, Jui-Yi

    2016-11-01

    Urban inundation forecasting with extended lead times is useful in saving lives and property. This study proposes the integration of rainfall thresholds and ensemble precipitation forecasts to provide probabilistic urban inundation forecasts. Utilization of ensemble precipitation forecasts can extend forecast lead times to 72 h, predicting peak flows and to allow response agencies to take necessary preparatory measures. However, ensemble precipitation forecasting is time- and resource-intensive. Using rainfall thresholds to estimate urban areas' inundation risk can decrease this complexity and save computation time. This study evaluated the performance of this system using 352 townships in Taiwan and seven typhoons during the period 2013-2015. The levels of forecast probability needed to issue inundation alerts were addressed because ensemble forecasts are probability based. This study applied six levels of forecast probability and evaluated their performance using five measures. The results showed that this forecasting system performed better before a typhoon made landfall. Geography had a strong impact at the start of the numerical weather modeling, resulting in the underestimation of rainfall forecasts. Regardless of this finding, the inundation forecast performance was highly contingent on the rainfall forecast skill. This study then tested a hybrid approach of on-site observations and rainfall forecasts to decrease the influence of numerical weather predictions and improve the forecast performance. The results of this combined system showed that forecasts with a 24 h lead time improved significantly. These findings and the hybrid approach can be applied to other hydrometeorological early warning systems to improve hazard-related forecasts.

  4. Health system strengthening in Myanmar during political reforms: perspectives from international agencies.

    PubMed

    Risso-Gill, Isabelle; McKee, Martin; Coker, Richard; Piot, Peter; Legido-Quigley, Helena

    2014-07-01

    Myanmar has undergone a remarkable political transformation in the last 2 years, with its leadership voluntarily transitioning from an isolated military regime to a quasi-civilian government intent on re-engaging with the international community. Decades of underinvestment have left the country underdeveloped with a fragile health system and poor health outcomes. International aid agencies have found engagement with the Myanmar government difficult but this is changing rapidly and it is opportune to consider how Myanmar can engage with the global health system strengthening (HSS) agenda. Nineteen semi-structured, face-to-face interviews were conducted with representatives from international agencies working in Myanmar to capture their perspectives on HSS following political reform. They explored their perceptions of HSS and the opportunities for implementation. Participants reported challenges in engaging with government, reflecting the disharmony between actors, economic sanctions and barriers to service delivery due to health system weaknesses and bureaucracy. Weaknesses included human resources, data and medical products/infrastructure and logistical challenges. Agencies had mixed views of health system finance and governance, identifying problems and also some positive aspects. There is little consensus on how HSS should be approached in Myanmar, but much interest in collaborating to achieve it. Despite myriad challenges and concerns, participants were generally positive about the recent political changes, and remain optimistic as they engage in HSS activities with the government.

  5. 4. Missile Alert Facility, outside gate, view looking southwest. Thalheimer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Missile Alert Facility, outside gate, view looking southwest. Thalheimer - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  6. 3. Missile Alert Facility, northwest corner, view from bleachers. Lyon ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Missile Alert Facility, northwest corner, view from bleachers. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  7. 6. Missile Alert Facility, west side. Thalheimer Whiteman Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Missile Alert Facility, west side. Thalheimer - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  8. 8. Missile Alert Facility, northeast corner. Lyon Whiteman Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Missile Alert Facility, northeast corner. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  9. 2. Missile Alert Facility, south side, view from baseball bleachers. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Missile Alert Facility, south side, view from baseball bleachers. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  10. 29. Launch Control Center, view looking in, alert crew mannequin ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. Launch Control Center, view looking in, alert crew mannequin at end of Launch Control Center. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  11. 1. Missile Alert Facility, east side, view from bleachers on ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Missile Alert Facility, east side, view from bleachers on athletic field. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  12. 5. Missile Alert Facility, east and north sides, looking southwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Missile Alert Facility, east and north sides, looking southwest. Thalheimer - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  13. Inter-agency Working Group for Airborne Data and Telemetry Systems (IWGADTS)

    NASA Technical Reports Server (NTRS)

    Webster, Chris; Freudinger, Lawrence; Sorenson, Carl; Myers, Jeff; Sullivan, Don; Oolman, Larry

    2009-01-01

    The Interagency Coordinating Committee for Airborne Geosciences Research and Applications (ICCAGRA) was established to improve cooperation and communication among agencies sponsoring airborne platforms and instruments for research and applications, and to serve as a resource for senior level management on airborne geosciences issues. The Interagency Working Group for Airborne Data and Telecommunications Systems (IWGADTS) is a subgroup to ICCAGRA for the purpose of developing recommendations leading to increased interoperability among airborne platforms and instrument payloads, producing increased synergy among research programs with similar goals, and enabling the suborbital layer of the Global Earth Observing System of Systems.

  14. Implementing the National Integrated Ocean Observing System (IOOS): from the federal agency perspective

    USGS Publications Warehouse

    Bassett, R.; Beard, R.; Burnett, W.; Crout, R.; Griffith, B.; Jensen, R.; Signell, R.

    2010-01-01

    The national Integrated Ocean Observing System (IOOS??) is responsible for coordinating a network of people, resources, and technology to disseminate continuous data, information, models, products, and services made throughout our coastal waters, Great Lakes, and the oceans. There are many components of the IOOS-including government, academic, and private entities. This article will focus on some of the federal contributions to IOOS and describe the capabilities of several agency partners.

  15. Evaluation of the Early Alert Program, Spring 1999.

    ERIC Educational Resources Information Center

    Cartnal, Ryan; Hagen, Peter F.

    This report evaluates the Early Alert program at Cuesta College (California). The report is divided into four main sections: services accessed, accessibility, actions taken as a result of receiving an Early Alert letter, and timing and utility of the Early Alert program. These are followed by the demography of the respondents, a brief background…

  16. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Transmission of a distress alert. 80.1113... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... stations that a ship is in distress. These alerts are based on the use of transmissions via...

  17. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Transmission of a distress alert. 80.1113... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... stations that a ship is in distress. These alerts are based on the use of transmissions via...

  18. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Transmission of a distress alert. 80.1113... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... coast earth stations that a ship is in distress. These alerts are based on the use of transmissions...

  19. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmission of a distress alert. 80.1113... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... coast earth stations that a ship is in distress. These alerts are based on the use of transmissions...

  20. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Transmission of a distress alert. 80.1113... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... stations that a ship is in distress. These alerts are based on the use of transmissions via...

  1. Smart repeater system for communications interoperability during multi-agency law enforcement operations

    SciTech Connect

    Crutcher, R.I.; Jones, R.W.; Moore, M.R.; Smith, S.F.; Tolley, A.L.; Rochelle, R.W.

    1996-12-31

    A prototype smart repeater that provides interoperability capabilities for radio communication systems in multi-agency and multi-user scenarios is being developed by the Oak Ridge National Laboratory. The smart repeater functions as a deployable communications platform that can be dynamically reconfigured to cross-link the radios of participating federal, state, and local government agencies. This interconnection capability improves the coordination and execution of multi-agency operations, including coordinated law enforcement activities and general emergency or disaster response scenarios. The repeater provides multiple channels of operation in the 30--50, 118--136, 138--174, and 403--512 MHz land mobile communications and aircraft bands while providing the ability to cross-connect among multiple frequencies, bands, modulation types, and encryption formats. Additionally, two telephone interconnects provide links to the fixed and cellular telephone networks. The 800- and 900-MHz bands are not supported by the prototype, but the modular design of the system accommodates future retrofits to extend frequency capabilities with minimal impact to the system. Configuration of the repeater is through a portable personal computer with a Windows-based graphical interface control screen that provides dynamic reconfiguration of network interconnections and formats.

  2. Personalized Alert Notifications and Evacuation Routes in Indoor Environments

    PubMed Central

    Aedo, Ignacio; Yu, Shuxin; Díaz, Paloma; Acuña, Pablo; Onorati, Teresa

    2012-01-01

    The preparedness phase is crucial in the emergency management process for reaching an adequate level of readiness to react to potential threats and hazards. During this phase, emergency plans are developed to establish, among other procedures, evacuation and emergency escape routes. Information and Communication Technologies (ICT) can support and improve these procedures providing appropriate, updated and accessible information to all people in the affected zone. Current emergency management and evacuation systems do not adapt information to the context and the profile of each person, so messages received in the emergency might be useless. In this paper, we propose a set of criteria that ICT-based systems could achieve in order to avoid this problem adapting emergency alerts and evacuation routes to different situations and people. Moreover, in order to prove the applicability of such criteria, we define a mechanism that can be used as a complement of traditional evacuation systems to provide personalized alerts and evacuation routes to all kinds of people during emergency situations in working places. This mechanism is composed by three main components: CAP-ONES for notifying emergency alerts, NERES for defining emergency plans and generating personalized evacuation routes, and iNeres as the interface to receive and visualize these routes on smartphones. The usability and understandability of proposed interface has been assessed through a user study performed in a fire simulation in an indoor environment. This evaluation demonstrated that users considered iNeres easy to understand, to learn and to use, and they also found very innovative the idea to use smartphones as a support for escaping instead of static signals on walls and doors. PMID:22969373

  3. Education and Training Module in Alertness Management

    NASA Technical Reports Server (NTRS)

    Mallis, M. M.; Brandt, S. L.; Oyung, R. L.; Reduta, D. D.; Rosekind, M. R.

    2006-01-01

    The education and training module (ETM) in alertness management has now been integrated as part of the training regimen of the Pilot Proficiency Awards Program ("WINGS") of the Federal Aviation Administration. Originated and now maintained current by the Fatigue Countermeasures Group at NASA Ames Research Center, the ETM in Alertness Management is designed to give pilots the benefit of the best and most recent research on the basics of sleep physiology, the causes of fatigue, and strategies for managing alertness during flight operations. The WINGS program is an incentive program that encourages pilots at all licensing levels to participate in recurrent training, upon completion of which distinctive lapel or tie pins (wings) and certificates of completion are awarded. In addition to flight training, all WINGS applicants must attend at least one FAA-sponsored safety seminar, FAA-sanctioned safety seminar, or industry recurrent training program. The Fatigue Countermeasures Group provides an FAA-approved industry recurrent training program through an on-line General Aviation (GA) WINGS ETM in alertness management to satisfy this requirement. Since 1993, the Fatigue Countermeasures Group has translated fatigue and alertness information to operational environments by conducting two-day ETM workshops oriented primarily toward air-carrier operations subject to Part 121 of the Federal Aviation Regulations pertaining to such operations. On the basis of the information presented in the two-day ETM workshops, an ETM was created for GA pilots and was transferred to a Web-based version. To comply with the requirements of the WINGS Program, the original Web-based version has been modified to include hypertext markup language (HTML) content that makes information easily accessible, in-depth testing of alertness-management knowledge, new interactive features, and increased informational resources for GA pilots. Upon successful completion of this training module, a participant

  4. Applying the XForms Standard to Public Health Case Reporting and Alerting

    PubMed Central

    Hills, Rebecca A; Baseman, Janet G; Revere, Debra; Boge, Craig L K; Oberle, Mark W; Doctor, Jason N; Lober, William B

    2011-01-01

    Notifiable condition reporting and alerting are two important public health functions. Today, a variety of methods are used to transfer these types of information. The increasing use of electronic health record systems by healthcare providers makes new types of electronic communication possible. We used the XForms standard and nationally recognized technical profiles to demonstrate the communication of both notifiable condition reports and patient-tailored public health alerts. This demonstration of bi-directional communication took placein a prototypical health information exchange environment. We successfully transferred information between provider electronic health record systems and public health systems for notifiable condition reporting. Patient-specific alerts were successfully sent from public health to provider systems. In this paper we discuss the benefits of XForms, including the use of XML, advanced form controls, form initialization and reduction in scripting. We also review implementation challenges, the maturity of the technology and its suitability for use in public health. PMID:23569609

  5. Thermal Energy for Space Cooling--Federal Technology Alert

    SciTech Connect

    Brown, Daryl R.

    2000-12-31

    Cool storage technology can be used to significantly reduce energy costs by allowing energy-intensive, electrically driven cooling equipment to be predominantly operated during off peak hours when electricity rates are lower. This Federal Technology Alert, which is sponsored by DOE's Federal Energy Management Program (FEMP), describes the basic types of cool storage technologies and cooling system integration options. In addition, it defines the savings potential in the federal sector, presents application advice, and describes the performance experience of specific federal users. The results of a case study of a GSA building using cool storage technology are also provided.

  6. Government Agencies

    DTIC Science & Technology

    1988-05-01

    manufacturers. The Navy has a major in- house design capability for ships; the government does not possess such a capability for aircraft or other weapon systems...the Coast Guard, government agencies acquire a wide variety of ships, ranging from sophisticated submarines and nuclear aircraft carriers to much...the initial phase a review was made of written material relating to government procedures in U.S. Government agencies for acquiring vessels, aircraft

  7. Runway Safety Monitor Algorithm for Runway Incursion Detection and Alerting

    NASA Technical Reports Server (NTRS)

    Green, David F., Jr.; Jones, Denise R. (Technical Monitor)

    2002-01-01

    The Runway Safety Monitor (RSM) is an algorithm for runway incursion detection and alerting that was developed in support of NASA's Runway Incursion Prevention System (RIPS) research conducted under the NASA Aviation Safety Program's Synthetic Vision System element. The RSM algorithm provides pilots with enhanced situational awareness and warnings of runway incursions in sufficient time to take evasive action and avoid accidents during landings, takeoffs, or taxiing on the runway. The RSM currently runs as a component of the NASA Integrated Display System, an experimental avionics software system for terminal area and surface operations. However, the RSM algorithm can be implemented as a separate program to run on any aircraft with traffic data link capability. The report documents the RSM software and describes in detail how RSM performs runway incursion detection and alerting functions for NASA RIPS. The report also describes the RIPS flight tests conducted at the Dallas-Ft Worth International Airport (DFW) during September and October of 2000, and the RSM performance results and lessons learned from those flight tests.

  8. Caffeine: implications for alertness in athletes.

    PubMed

    Rogers, Naomi L; Dinges, David F

    2005-04-01

    Caffeine is one of the most widely consumed drugs in the world, taken socially and for its alertness- and performance-promoting actions. Extensive reports assert that caffeine increases alertness and cognitive performance levels and, when taken before exercise, demonstrates ergogenic properties. Caffeine ingestion has been associated with increased performance during endurance submaximal, and acute, high-intensity exercise. The exact mechanism of action for the performance effects of caffeine is unknown, although several physiologically and psychologically based theories exist as to how caffeine achieves increased performance capabilities. This paper outlines the known sites of caffeine activity in the body,and discusses these with respect to the effects of caffeine observed during performance assessments.

  9. Review of the Tri-Agency Space Nuclear Reactor Power System Technology Program

    NASA Technical Reports Server (NTRS)

    Ambrus, J. H.; Wright, W. E.; Bunch, D. F.

    1984-01-01

    The Space Nuclear Reactor Power System Technology Program designated SP-100 was created in 1983 by NASA, the U.S. Department of Defense, and the Defense Advanced Research Projects Agency. Attention is presently given to the development history of SP-100 over the course of its first year, in which it has been engaged in program objectives' definition, the analysis of civil and military missions, nuclear power system functional requirements' definition, concept definition studies, the selection of primary concepts for technology feasibility validation, and the acquisition of initial experimental and analytical results.

  10. Health-Care Provider Preferences for Time-Sensitive Communications from Public Health Agencies

    PubMed Central

    Revere, Debra; Painter, Ian; Oberle, Mark

    2014-01-01

    Objective The Rapid Emergency Alert Communication in Health (REACH) Trial was a randomized control trial to systematically compare and evaluate the effectiveness of traditional and mobile communication modalities for public health agencies to disseminate time-sensitive information to health-care providers (HCPs). We conducted a sub-study to identify the communication channels by which HCPs preferred receiving public health alerts and advisories. Methods Enrolled HCPs were blindly randomized into four message delivery groups to receive time-sensitive public health messages by e-mail, fax, or short message service (SMS) or to a no-message control group. Follow-up interviews were conducted 5–10 days after the message. In the final interview, additional questions were asked regarding HCP preferences for receiving public health alerts and advisories. We examined the relationship between key covariates and preferred method of receiving public health alert and advisory messages. Results Gender, age, provider type, and study site showed statistically significant associations with delivery method preference. Older providers were more likely than younger providers to prefer e-mail or fax, while younger providers were more likely than older providers to prefer receiving messages via SMS. Conclusions There is currently no evidence-based research to guide or improve communication between public health agencies and HCPs. Understanding the preferences of providers for receiving alerts and advisories may improve the effectiveness of vital public health communications systems and, in turn, may enhance disease surveillance, aid in early detection, and improve case finding and situational awareness for public health emergencies. PMID:25355977

  11. Best Practices in Wireless Emergency Alerts

    DTIC Science & Technology

    2014-02-01

    015 | 33 Value is measured in terms of the types of outcomes expected. For example, a practice that reduc- es property damage from a storm could be...of value to the alert originating community. 3. WEA Best Practices must present information with clarity. They must be clearly written us- ing terms...must be effective. They must show a measurable improvement over al- ternative practices. Based on these guidelines, the researchers further developed

  12. [Advance in application of syndromic surveillance for detection of emerging infectious diseases and outbreak alerts].

    PubMed

    Lin, Mei; Wang, Xin; Liang, Dabin

    2015-07-01

    Over the past decade, syndromic surveillance, as supplementation of disease surveillance, has provided possibility of early alert in a real-time way for detection of emerging infectious diseases and outbreaks of widespread infectious diseases, resulting in improvement in sensitivity of outbreak detection and public health alert capacity. This tool has been highly valued and widely used in the world, and effective implementation has been observed in China. Upon abundant literature search, the authors reviewed the progress and advance of syndromic surveillance in early alert of emerging infectious diseases and outbreaks, and analyzed the problem met in the current situation in China when implementing syndromic surveillance in local facilities, which are high cost, lack of medical information platform, lack of real-time digital alert system and lack of a comprehensive information exchange platform. The authors suggested that syndromic surveillance should be implemented considering the local situation and performed in a more effective way in the current situation. Syndromic surveillance has to be integrated into the conventional public health surveillance systems and advanced laboratory networks. Digital information system is urgently needed to achieve real-time alert.

  13. Federal technology alert: Ultrasonic humidifiers

    SciTech Connect

    1998-11-01

    Humidifiers are used in buildings to maintain humidity levels to ensure quality and handling capabilities in manufacturing processes, to lower the transmission rate of disease-causing bacteria in hospitals, to reduce static electricity in manufacturing clean rooms and in computer rooms, and to provide higher levels of employee comfort in offices. Ultrasonic humidifiers generate a water mist without raising its temperature. An electronic oscillation is converted to a mechanical oscillation using a piezo disk immersed in a reservoir of mineral-free water. The mechanical oscillation is directed at the surface of the water, where at very high frequencies it creates a very fine mist of water droplets. This adiabatic process, which does not heat the supply water, reduces humidifier energy use by 90 to 93% compared with systems that do boil the water. Ultrasonic humidifiers have been demonstrated to be more efficient and to require less maintenance than competing humidifier technologies such as electrode canisters, quartz lamps, and indirect steam-to-steam. They do not require anticorrosive additives that affect the indoor air quality of buildings using direct steam humidifiers. There are two potential disadvantages of ultrasonic humidifiers. They must use mineral-free, deionized water or water treated with reverse osmosis. Treated water reduces maintenance costs because it eliminates calcium deposits, but increases other operating costs. Also, the cool mist from ultrasonic humidifiers absorbs energy from the supply air as it evaporates and provides a secondary cooling effect.

  14. Can Seizure-Alert Dogs predict seizures?

    PubMed

    Brown, Stephen W; Goldstein, Laura H

    2011-12-01

    An index observation where a dog was trained to alert to, as well as respond to, human tonic-clonic seizures led to further research and refinement of training techniques. This was followed by anecdotal reports of pet dogs spontaneously anticipating human epileptic seizures. An industry has since developed training Seizure-Alert Dogs (SADs) to give humans warnings of their seizures. In some cases this has been accompanied by a reduction in seizure frequency. SADs may be trained along with the person with epilepsy, responding specifically to that person's seizures, or may be trained separately. Recent sceptical reports of non-epileptic seizures in some people with SADs have cast doubt on dogs' ability to anticipate true epileptic seizures. This may reflect selection criteria for training programmes as well as training methods used, but does not necessarily indicate that SADs might not be able to predict epileptic seizures. Whether the seizures are epileptic or non-epileptic, it is speculated that SADs probably alert to subtle pre-ictal human behaviour changes, but may also be sensitive to heart rate or olfactory cues. As yet, however, no rigorous data exist as to whether seizure prediction by SADS is better than chance, and what false positive and negative prediction rates might be.

  15. EEG quantification of alertness: methods for early identification of individuals most susceptible to sleep deprivation

    NASA Astrophysics Data System (ADS)

    Berka, Chris; Levendowski, Daniel J.; Westbrook, Philip; Davis, Gene; Lumicao, Michelle N.; Olmstead, Richard E.; Popovic, Miodrag; Zivkovic, Vladimir T.; Ramsey, Caitlin K.

    2005-05-01

    Electroencephalographic (EEG) and neurocognitive measures were simultaneously acquired to quantify alertness from 24 participants during 44-hours of sleep deprivation. Performance on a three-choice vigilance task (3C-VT), paired-associate learning/memory task (PAL) and modified Maintenance of Wakefulness Test (MWT), and sleep technician-observed drowsiness (eye-closures, head-nods, EEG slowing) were quantified. The B-Alert system automatically classifies each second of EEG on an alertness/drowsiness continuum. B-Alert classifications were significantly correlated with technician-observations, visually scored EEG and performance measures. B-Alert classifications during 3C-VT, and technician observations and performance during the 3C-VT and PAL evidenced progressively increasing drowsiness as a result of sleep deprivation with a stabilizing effect observed at the batteries occurring between 0600 and 1100 suggesting a possible circadian effect similar to those reported in previous sleep deprivation studies. Participants were given an opportunity to take a 40-minute nap approximately 24-hours into the sleep deprivation portion of the study (i.e., 7 PM on Saturday). The nap was followed by a transient period of increased alertness. Approximately 8 hours after the nap, behavioral and physiological measures of drowsiness returned to levels prior to the nap. Cluster analysis was used to stratify individuals into three groups based on their level of impairment as a result of sleep deprivation. The combination of B-Alert and neuro-behavioral measures may identify individuals whose performance is most susceptible to sleep deprivation. These objective measures could be applied in an operational setting to provide a "biobehavioral assay" to determine vulnerability to sleep deprivation.

  16. Responses to intimate partner violence in Kakuma refugee camp: refugee interactions with agency systems.

    PubMed

    Horn, Rebecca

    2010-01-01

    Intimate partner violence (IPV) has been recognised as a significant problem amongst forcibly displaced communities, and great progress has been made by the United Nations High Commission for Refugees (UNHCR) in responding to IPV and other forms of sexual and gender based violence. However, they have not always effectively engaged refugee communities in these activities, with potentially negative consequences for the health and protection of women. This study was conducted in Kakuma refugee camp, north-west Kenya. Eighteen focus group discussions were conducted with 157 refugees from various nationalities, including Sudanese, Somali, Ethiopian, and Congolese. They focused on the nature and consequences of IPV in Kakuma. The aim of this paper is to explore how refugees in Kakuma talk about the ways that IPV is dealt with, focusing particularly on the ways that community responses are said to interact with formal response systems established by UNHCR and its implementing partners. Refugees talked about using a 'hierarchy of responses' to IPV, with only particularly serious or intransigent cases reaching UNHCR or its implementing agencies. Some male refugees described being mistrustful of agency responses, because agencies were believed to favour women and to prioritise protecting the woman at all costs, even if that means separating her from the family. Whilst community responses to IPV might often be appropriate and helpful, the findings of the current study suggest that in Kakuma they do not necessarily result in the protection of women. Yet women in Kakuma are reported to be reluctant to report their cases to UNHCR and its implementing agencies. A more effective protection response from UNHCR might involve closer co-operation with individuals and structures within the refugee communities to develop a co-ordinated response to IPV.

  17. Automated health alerts from Kinect-based in-home gait measurements.

    PubMed

    Stone, Erik E; Skubic, Marjorie; Back, Jessica

    2014-01-01

    A method for automatically generating alerts to clinicians in response to changes in in-home gait parameters is investigated. Kinect-based gait measurement systems were installed in apartments in a senior living facility. The systems continuously monitored the walking speed, stride time, and stride length of apartment residents. A framework for modeling uncertainty in the residents' gait parameter estimates, which is critical for robust change detection, is developed; along with an algorithm for detecting changes that may be clinically relevant. Three retrospective case studies, of individuals who had their gait monitored for periods ranging from 12 to 29 months, are presented to illustrate use of the alert method. Evidence suggests that clinicians could be alerted to health changes at an early stage, while they are still small and interventions may be most successful. Additional potential uses are also discussed.

  18. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    NASA Technical Reports Server (NTRS)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  19. Alert!: In Emergencies, Schools Use Technology to Get the Message out Quickly

    ERIC Educational Resources Information Center

    Violino, Bob

    2008-01-01

    This article describes how a growing number of community colleges have begun deploying emergency alert systems that can be used to send information via e-mail and text messaging directly to students' cell phones and other portable devices. Such systems enable authorized campus administrators to send messages to thousands of people within minutes.…

  20. Airborne derivation of microburst alerts from ground-based Terminal Doppler Weather Radar information: A flight evaluation

    NASA Technical Reports Server (NTRS)

    Hinton, David A.

    1993-01-01

    An element of the NASA/FAA windshear program is the integration of ground-based microburst information on the flight deck, to support airborne windshear alerting and microburst avoidance. NASA conducted a windshear flight test program in the summer of 1991 during which airborne processing of Terminal Doppler Weather Radar (TDWR) data was used to derive microburst alerts. Microburst information was extracted from TDWR, transmitted to a NASA Boeing 737 in flight via data link, and processed to estimate the windshear hazard level (F-factor) that would be experienced by the aircraft in each microburst. The microburst location and F-factor were used to derive a situation display and alerts. The situation display was successfully used to maneuver the aircraft for microburst penetrations, during which atmospheric 'truth' measurements were made. A total of 19 penetrations were made of TDWR-reported microburst locations, resulting in 18 airborne microburst alerts from the TDWR data and two microburst alerts from the airborne reactive windshear detection system. The primary factors affecting alerting performance were spatial offset of the flight path from the region of strongest shear, differences in TDWR measurement altitude and airplane penetration altitude, and variations in microburst outflow profiles. Predicted and measured F-factors agreed well in penetrations near microburst cores. Although improvements in airborne and ground processing of the TDWR measurements would be required to support an airborne executive-level alerting protocol, the practicality of airborne utilization of TDWR data link data has been demonstrated.

  1. Integrative Indicator for Assessing the Alert Levels of Algal Bloom in Lakes: Lake Taihu as a Case Study

    NASA Astrophysics Data System (ADS)

    Li, Qinqin; Hu, Weiping; Zhai, Shuhua

    2016-01-01

    Algal blooms have recently become one of the most serious environmental problems in eutrophic freshwater ecosystems worldwide. Although many observation and simulation approaches have been applied to predict algal blooms, few studies have addressed the alert levels of algal blooms using integrative indicators in a large lake with multiple service function and significant horizontal heterogeneity. This study developed an integrative indicator assessment system (IIAS) to rank the alert level of algal blooms. In the IIAS, algal biomass, area percentage, distance from drinking water intake points, distance from scenic zones and duration of algal bloom were used as indicators to calculate a comprehensive alert level, which was classified into five grades (Vigilance, Low, Moderate, High, and Severe). Lake Taihu was taken as a case study to assess the comprehensive alert level of algal blooms in 2007 and 2010. The comprehensive alert level showed obvious spatial-temporal patterns, with an acceptable accuracy in Lake Taihu. The comprehensive alert levels were relatively higher in typical phytoplankton subzones than typical hydrophytes subzones and are more sensitive to weight factor in the northern and western subzones where high biomass usually occurs. Case study showed a very good application of the proposed comprehensive alert level assessment methodology, which can be adjusted to predict the degree of hazard of algal blooms in multi-service function large lakes to help the government and decision makers to act to prevent the disaster from algal bloom spreading.

  2. Automated Health Alerts Using In-Home Sensor Data for Embedded Health Assessment

    PubMed Central

    Guevara, Rainer Dane; Rantz, Marilyn

    2015-01-01

    We present an example of unobtrusive, continuous monitoring in the home for the purpose of assessing early health changes. Sensors embedded in the environment capture behavior and activity patterns. Changes in patterns are detected as potential signs of changing health. We first present results of a preliminary study investigating 22 features extracted from in-home sensor data. A 1-D alert algorithm was then implemented to generate health alerts to clinicians in a senior housing facility. Clinicians analyze each alert and provide a rating on the clinical relevance. These ratings are then used as ground truth for training and testing classifiers. Here, we present the methodology for four classification approaches that fuse multisensor data. Results are shown using embedded sensor data and health alert ratings collected on 21 seniors over nine months. The best results show similar performance for two techniques, where one approach uses only domain knowledge and the second uses supervised learning for training. Finally, we propose a health change detection model based on these results and clinical expertise. The system of in-home sensors and algorithms for automated health alerts provides a method for detecting health problems very early so that early treatment is possible. This method of passive in-home sensing alleviates compliance issues. PMID:27170900

  3. Reduced visual disengagement but intact phasic alerting in young children with autism.

    PubMed

    Kleberg, Johan Lundin; Thorup, Emilia; Falck-Ytter, Terje

    2017-03-01

    Children with autism may have difficulties with visual disengagement-that is, inhibiting current fixations and orienting to new stimuli in the periphery. These difficulties may limit these children's ability to flexibly monitor the environment, regulate their internal states, and interact with others. In typical development, visual disengagement is influenced by a phasic alerting network that increases the processing speed of the visual system after salient events. The role of the phasic alerting effect in the putative atypical disengagement performance in autism spectrum disorder (ASD) is not known. Here, we compared visual disengagement in six-year-old children with autism (N = 18) and typically developing children (N = 17) matched for age and nonverbal IQ. We manipulated phasic alerting during a visual disengagement task by adding spatially nonpredictive sounds shortly before the onset of the visual peripheral targets. Children with ASD showed evidence of delayed disengagement compared to the control group. Sounds facilitated visual disengagement similarly in both groups, suggesting typical modulation by phasic alerting in ASD in the context of this task. These results support the view that atypical visual disengagement in ASD is related to other factors than atypicalities in the alerting network. Autism Res 2017, 10: 539-545. © 2016 The Authors Autism Research published by Wiley Periodicals, Inc. on behalf of International Society for Autism Research.

  4. De-alerting of U.S. nuclear forces: a critical appraisal

    SciTech Connect

    Bailey, K C; Barish, F

    1998-08-21

    Since the end of the Cold War, there have been pressures by disarmament advocates to move more quickly to draw down, toward zero, the number of nuclear weapons in U.S. and Russian arsenals. They criticize the process of negotiating arms control agreements as being too slow, and point out that treaty implementation is hampered by the necessity of ratification by the U.S. Senate and Russian Duma. One method of moving more rapidly toward nuclear abolition suggested by some analysts is de-alerting of nuclear-weapon delivery systems. De-alerting is defined as taking steps that increase significantly the time required to launch a given delivery vehicle armed with a nuclear warhead. Although there is little inclination by the U.S. Government to de-alert its nuclear forces at present, some academic literature and press stories continue to advocate such steps. This paper offers a critique of de-alerting proposals together with an assessment of the dangers of accidental, unauthorized, or unintended use of nuclear weapons. It concludes that de-alerting nuclear forces would be extremely de-stabilizing, principally because it would increase the value to an opponent of launching a first strike.

  5. CAT: the INGV Tsunami Alert Center

    NASA Astrophysics Data System (ADS)

    Michelini, A.

    2014-12-01

    After the big 2004 Sumatra earthquake, the tsunami threat posed by large earthquakes occurring in the Mediterranean sea was formally taken into account by many countries around the Mediterranean basin. In the past, large earthquakes that originated significant tsunamis occurred nearly once per century (Maramai et al., 2014, Annals of Geophysics). The Intergovernmental Oceanographic Commission of UNESCO (IOC-UNESCO) received a mandate from the international community to coordinate the establishment of the ICG/NEAMTWS (http://neamtic.ioc-unesco.org) through Resolution IOC-XXIII-14. Since then, several countries (France, Turkey, Greece) have started operating as candidate Tsunami Watch Provider (cTWP) in the Mediterranean. Italy started operating as cTWP on October 1st, 2014. The Italian cTWP is formed by INGV ("Istituto Nazionale di Geofisica e Vulcanologia)", DPC ("Dipartimento di Protezione Civile") and ISPRA ("Istituto Superiore per la Protezione e la Ricerca Ambientale"). INGV is in charge of issuing the alert for potentially tsunamigenic earthquakes, ISPRA provides the sea level recordings and DPC is in charge of disseminating the alert. INGV established the tsunami alert center (CAT, "Centro di Allerta Tsunami") at the end of 2013. CAT is co-located with the INGV national seismic surveillance center operated since many years. In this work, we show the technical and personnel organization of CAT, its response to recent earthquakes, and the new procedures under development for implementation. (*) INGV-CAT WG: Amato A., Basili R., Bernardi F., Bono A., Danecek P., De Martini P.M., Govoni A., Graziani L., Lauciani V., Lomax, A., Lorito S., Maramai A., Mele F., Melini D., Molinari I., Nostro C., Piatanesi A., Pintore S., Quintiliani M., Romano F., Selva J., Selvaggi G., Sorrentino D., Tonini R.

  6. Automatic Clock and Time Signal System of the Astronomical Agency in East Asia Area

    NASA Astrophysics Data System (ADS)

    Lee, Yong Sam

    2009-09-01

    We analysed the old automatic clock and time signal system that was used by the national astronomical agency in East Asian Area. Jagyeongnu is a kind of water clock that was operated by the flowing water in Joseon Dynasty. Seowoongwan managed the water clock so as to keep the standard time system in the dynasty from the 16th year (1434) of King Sejong's reign. In 1438 the Okru that was invented in the period. Such kind of clock system already was used in China, which was Shui yun i hsiang t'ai (?) in 1092. During the period Joseon Dynasty, China and Japan had been kept the time system that one day is divided into 12 shin (?2?) or 100 gak (?). However detailed part of the system had a little difference among the three countries. Though the whole system of water clock in Joseon had manufactured on the basis of Chinese, it had been gradually developed by own method and idea. In this study we show the historical records of the standard time keeping system in East Asian history. And then we can inform materials on the structure and functional devises for the purpose of new restoration models about the automatic clock and time system.

  7. Towards cross-lingual alerting for bursty epidemic events

    PubMed Central

    2011-01-01

    Background Online news reports are increasingly becoming a source for event-based early warning systems that detect natural disasters. Harnessing the massive volume of information available from multilingual newswire presents as many challanges as opportunities due to the patterns of reporting complex spatio-temporal events. Results In this article we study the problem of utilising correlated event reports across languages. We track the evolution of 16 disease outbreaks using 5 temporal aberration detection algorithms on text-mined events classified according to disease and outbreak country. Using ProMED reports as a silver standard, comparative analysis of news data for 13 languages over a 129 day trial period showed improved sensitivity, F1 and timeliness across most models using cross-lingual events. We report a detailed case study analysis for Cholera in Angola 2010 which highlights the challenges faced in correlating news events with the silver standard. Conclusions The results show that automated health surveillance using multilingual text mining has the potential to turn low value news into high value alerts if informed choices are used to govern the selection of models and data sources. An implementation of the C2 alerting algorithm using multilingual news is available at the BioCaster portal http://born.nii.ac.jp/?page=globalroundup. PMID:22166371

  8. Alpha synchronization and anxiety: implications for inhibition vs. alertness hypotheses.

    PubMed

    Knyazev, Gennady G; Savostyanov, Alexander N; Levin, Evgenij A

    2006-02-01

    Although there is much evidence that alpha oscillations are linked with processes of perception, attention and semantic memory, their functional significance remains uncertain. Synchronization in the alpha frequency range is taken to be a marker of cognitive inactivity, active inhibition of sensory information, or a means of inhibition of non-task relevant cortical areas. Here we propose an alternative interpretation which posits that higher alpha power during reference interval signifies higher readiness of alpha system to information processing. Predictions derived from the inhibition and alertness hypotheses were tested during presentation of acoustic stimuli (tone 1000 Hz) and neutral words to 30 males (18-25 years) with different levels of trait anxiety. On the whole, predictions derived from the inhibition theory were not confirmed and findings more corresponded to the alertness hypothesis. High-anxiety subjects showed higher alpha power during reference interval simultaneously with higher magnitude of event-related desynchronization and higher amplitude of phase-locked alpha responses. These findings are discussed in terms of functional significance of alpha band synchronization and desynchronization.

  9. Relationship between alertness, performance, and body temperature in humans

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth P Jr; Hull, Joseph T.; Czeisler, Charles A.

    2002-01-01

    Body temperature has been reported to influence human performance. Performance is reported to be better when body temperature is high/near its circadian peak and worse when body temperature is low/near its circadian minimum. We assessed whether this relationship between performance and body temperature reflects the regulation of both the internal biological timekeeping system and/or the influence of body temperature on performance independent of circadian phase. Fourteen subjects participated in a forced desynchrony protocol allowing assessment of the relationship between body temperature and performance while controlling for circadian phase and hours awake. Most neurobehavioral measures varied as a function of internal biological time and duration of wakefulness. A number of performance measures were better when body temperature was elevated, including working memory, subjective alertness, visual attention, and the slowest 10% of reaction times. These findings demonstrate that an increased body temperature, associated with and independent of internal biological time, is correlated with improved performance and alertness. These results support the hypothesis that body temperature modulates neurobehavioral function in humans.

  10. Post-crisis analysis of an ineffective tsunami alert: the 2010 earthquake in Maule, Chile.

    PubMed

    Soulé, Bastien

    2014-04-01

    Considering its huge magnitude and its location in a densely populated area of Chile, the Maule seism of 27 February 2010 generated a low amount of victims. However, post-seismic tsunamis were particularly devastating on that day; surprisingly, no full alert was launched, not at the national, regional or local level. This earthquake and associated tsunamis are of interest in the context of natural hazards management as well as crisis management planning. Instead of focusing exclusively on the event itself, this article places emphasis on the process, systems and long-term approach that led the tsunami alert mechanism to be ineffectual. Notably, this perspective reveals interrelated forerunner signs of vulnerability.

  11. 40 CFR 35.936-21 - Delegation to State agencies; certification of procurement systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Treatment Works-Clean Water Act § 35.936-21 Delegation to State agencies; certification of procurement... documentation required under these sections. (b) If a State agency believes that State laws which...

  12. Sleepiness and alertness in American industries

    SciTech Connect

    Coleman, R.M.; Dillingham, J.; Dement, W.C.

    1989-01-01

    Recent evidence that industrial accidents may be caused in part by shiftworkers' lack of alertness has caused growing concern at the US Nuclear Regulatory Commission and within the scientific community. The purpose of the study reported in this paper was threefold: (1) Is sleepiness on the job specific to utility plants (2) Are performance and safety problems caused by sleepiness specific to utility plants (3) Are specific shift schedules associated with a higher prevalence of sleepiness Findings indicate sleepiness on the job among shiftworkers is a widespread problem, not limited to the nuclear power industry. The most common solution in American industry is to overstaff each shift and discipline sleeping employees. Results show this is not effective. A more proactive solution is recommended including some of the following: (1) Provide employees education to assist adjustment to shiftwork. (2) Design and implement shift schedules that are more compatible with human physiological capabilities. (3) Allow officially sanctioned napping on shift as is done in Japan. (4) Divide 6-, 8-, or 12-h shifts into smaller blocks of 2 to 3 h of primary duty. (5) make the environment where employees work more conductive to alertness. (6) Develop a firehouse type of schedule where some employees sleep throughout the night, but are awakened if operational problems arise. (7) Provide incentives to employees to adjust their life style to the night shift and reward them with time off.

  13. Upgrading of data acquisition software for centralized radiation monitoring system in Malaysian Nuclear Agency

    SciTech Connect

    Yussup, F. Ibrahim, M. M. Soh, S. C.; Hasim, H.; Haris, M. F.; Azman, A.; Razalim, F. A. A.; Yapp, R.; Ramli, A. A. M.

    2016-01-22

    With the growth of technology, many devices and equipments can be connected to the network and internet to enable online data acquisition for real-time data monitoring and control from monitoring devices located at remote sites. Centralized radiation monitoring system (CRMS) is a system that enables area radiation level at various locations in Malaysian Nuclear Agency (Nuklear Malaysia) to be monitored centrally by using a web browser. The Local Area Network (LAN) in Nuclear Malaysia is utilized in CRMS as a communication media for data acquisition of the area radiation levels from radiation detectors. The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software upgrading on the system server that is responsible to acquire and record the area radiation readings from the detectors. The recorded readings are called in a web programming to be displayed on a website. Besides the main feature which is acquiring the area radiation levels in Nuclear Malaysia centrally, the upgrading involves new features such as uniform time interval for data recording and exporting, warning system and dose triggering.

  14. Upgrading of data acquisition software for centralized radiation monitoring system in Malaysian Nuclear Agency

    NASA Astrophysics Data System (ADS)

    Yussup, F.; Ibrahim, M. M.; Haris, M. F.; Soh, S. C.; Hasim, H.; Azman, A.; Razalim, F. A. A.; Yapp, R.; Ramli, A. A. M.

    2016-01-01

    With the growth of technology, many devices and equipments can be connected to the network and internet to enable online data acquisition for real-time data monitoring and control from monitoring devices located at remote sites. Centralized radiation monitoring system (CRMS) is a system that enables area radiation level at various locations in Malaysian Nuclear Agency (Nuklear Malaysia) to be monitored centrally by using a web browser. The Local Area Network (LAN) in Nuclear Malaysia is utilized in CRMS as a communication media for data acquisition of the area radiation levels from radiation detectors. The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software upgrading on the system server that is responsible to acquire and record the area radiation readings from the detectors. The recorded readings are called in a web programming to be displayed on a website. Besides the main feature which is acquiring the area radiation levels in Nuclear Malaysia centrally, the upgrading involves new features such as uniform time interval for data recording and exporting, warning system and dose triggering.

  15. 20 CFR 411.582 - Can a State VR agency receive payment under the cost reimbursement payment system if a continuous...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Can a State VR agency receive payment under... Systems § 411.582 Can a State VR agency receive payment under the cost reimbursement payment system if a...? Yes. If a State VR agency provides services to a beneficiary under 34 CFR part 361, and elects...

  16. 20 CFR 411.582 - Can a State VR agency receive payment under the cost reimbursement payment system if a continuous...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Can a State VR agency receive payment under... Systems § 411.582 Can a State VR agency receive payment under the cost reimbursement payment system if a...? Yes. If a State VR agency provides services to a beneficiary under 34 CFR part 361, and elects...

  17. 20 CFR 411.365 - How does a State VR agency notify us about its choice of a payment system for use when...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false How does a State VR agency notify us about... agency notify us about its choice of a payment system for use when functioning as an EN? (a) The State VR agency must send us a letter telling us which EN payment system it will use when it functions as an...

  18. 20 CFR 411.365 - How does a State VR agency notify us about its choice of a payment system for use when...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false How does a State VR agency notify us about... agency notify us about its choice of a payment system for use when functioning as an EN? (a) The State VR agency must send us a letter telling us which EN payment system it will use when it functions as an...

  19. 20 CFR 411.365 - How does a State VR agency notify us about its choice of a payment system for use when...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false How does a State VR agency notify us about... agency notify us about its choice of a payment system for use when functioning as an EN? (a) The State VR agency must send us a letter telling us which EN payment system it will use when it functions as an...

  20. Chronotype and time-of-day influences on the alerting, orienting, and executive components of attention.

    PubMed

    Matchock, Robert L; Mordkoff, J Toby

    2009-01-01

    Recent research on attention has identified three separable components, known as alerting, orienting, and executive functioning, which are thought to be subserved by distinct neural networks. Despite systematic investigation into their relatedness to each other and to psychopathology, little is known about how these three networks might be modulated by such factors as time-of-day and chronotype. The present study administered the Attentional Network Test (ANT) and a self-report measure of alertness to 80 participants at 0800, 1200, 1600, and 2000 hours on the same day. Participants were also chronotyped with a morningness/eveningness questionnaire and divided into evening versus morning/neither-type groups; morning chronotypes tend to perform better early in the day, while evening chronotypes show enhanced performance later in the day. The results replicated the lack of any correlations between alerting, orienting, and executive functioning, supporting the independence of these three networks. There was an effect of time-of-day on executive functioning with higher conflict scores at 1200 and 1600 hours for both chronotypes. The efficiency of the orienting system did not change as a function of time-of-day or chronotype. The alerting measure, however, showed an interaction between time-of-day and chronotype such that alerting scores increased only for the morning/neither-type participants in the latter half of the day. There was also an interaction between time-of-day and chronotype for self-reported alertness, such that it increased during the first half of the day for all participants, but then decreased for morning/neither types (only) toward evening. This is the first report to examine changes in the trinity of attentional networks measured by the ANT throughout a normal day in a large group of normal participants, and it encourages more integration between chronobiology and cognitive neuroscience for both theoretical and practical reasons.