Sample records for align troponin complexes

  1. Label-Free Detection of Cardiac Troponin-I Using Carbon Nanofiber Based Nanoelectrode Arrays

    NASA Technical Reports Server (NTRS)

    Periyakaruppan, Adaikkappan; Koehne, Jessica Erin; Gandhiraman, Ram P.; Meyyappan, M.

    2013-01-01

    A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. A carbon nanofiber (CNF) multiplexed array has been fabricated with 9 sensing pads, each containing 40,000 carbon nanofibers as nanoelectrodes. Here, we report the use of vertically aligned CNF nanoelectrodes for the detection of cardiac Troponin-I for the early diagnosis of myocardial infarction. Antibody, antitroponin, probe immobilization and subsequent binding to human cardiac troponin-I were characterized using electrochemical impedance spectroscopy and cyclic voltammetry techniques. Each step of the modification process resulted in changes in electrical capacitance or resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific antigen. This sensor demonstrates high sensitivity, down to 0.2 ng/mL, and good selectivity making this platform a good candidate for early stage diagnosis of myocardial infarction.

  2. Structure and Function of Cardiac Troponin C (TNNC1): Implications for Heart Failure, Cardiomyopathies, and Troponin Modulating Drugs

    PubMed Central

    Li, Monica X.; Hwang, Peter M.

    2015-01-01

    In striated muscle, the protein troponin complex turns contraction on and off in a calcium-dependent manner. The calcium-sensing component of the complex is troponin C, which is expressed from the TNNC1 gene in both cardiac muscle and slow-twitch skeletal muscle (identical transcript in both tissues) and the TNNC2 gene in fast-twitch skeletal muscle. Cardiac troponin C (cTnC) is made up of two globular EF-hand domains connected by a flexible linker. The structural C-domain (cCTnC) contains two high affinity calcium-binding sites that are always occupied by Ca2+ or Mg2+ under physiologic conditions, stabilizing an open conformation that remains anchored to the rest of the troponin complex. In contrast, the regulatory N-domain (cNTnC) contains a single low affinity site that is largely unoccupied at resting calcium concentrations. During muscle activation, calcium binding to cNTnC favors an open conformation that binds to the switch region of troponin I, removing adjacent inhibitory regions of troponin I from actin and allowing muscle contraction to proceed. Regulation of the calcium binding affinity of cNTnC is physiologically important, because it directly impacts the calcium sensitivity of muscle contraction. Calcium sensitivity can be modified by drugs that stabilize the open form of cNTnC, post-translational modifications like phosphorylation of troponin I, or downstream thin filament protein interactions that impact the availability of the troponin I switch region. Recently, mutations in cTnC have been associated with hypertrophic or dilated cardiomyopathy. A detailed understanding of how calcium sensitivity is regulated through the troponin complex is necessary for explaining how mutations perturb its function to promote cardiomyopathy and how post-translational modifications in the thin filament affect heart function and heart failure. Troponin modulating drugs are being developed for the treatment of cardiomyopathies and heart failure. PMID:26232335

  3. Molecular dynamics studies on troponin (TnI-TnT-TnC) complexes: insight into the regulation of muscle contraction.

    PubMed

    Varughese, Jayson F; Chalovich, Joseph M; Li, Yumin

    2010-10-01

    Mutations of any subunit of the troponin complex may lead to serious disorders. Rational approaches to managing these disorders require knowledge of the complex interactions among the three subunits that are required for proper function. Molecular dynamics (MD) simulations were performed for both skeletal (sTn) and cardiac (cTn) troponin. The interactions and correlated motions among the three components of the troponin complex were analyzed using both Molecular Mechanics-Generalized Born Surface Area (MMGBSA) and cross-correlation techniques. The TnTH2 helix was strongly positively correlated with the two long helices of TnI. The C domain of TnC was positively correlated with TnI and TnT. The N domain of TnC was negatively correlated with TnI and TnT in cTn, but not in sTn. The two C-domain calcium-binding sites of TnC were dynamically correlated. The two regulatory N-domain calcium-binding sites of TnC were dynamically correlated, even though the calcium-binding site I is dysfunctional. The strong interaction residue pairs and the strong dynamically correlated residues pairs among the three components of troponin complexes were identified. These correlated motions are consistent with the idea that there is a high degree of cooperativity among the components of the regulatory complex in response to Ca(2+) and other effectors. This approach may give insight into the mechanism by which mutations of troponin cause disease. It is interesting that some observed disease causing mutations fall within regions of troponin that are strongly correlated or interacted.

  4. Predictors of Peak Troponin Level in Acute Coronary Syndromes: Prior Aspirin Use and SYNTAX Score

    PubMed Central

    Bhatt, Hemal A.; Sanghani, Dharmesh R.; Lee, David; Julliard, Kell N.; Fernaine, George A.

    2015-01-01

    The peak troponin level has been associated with cardiovascular (CV) mortality and adverse CV events. The association of peak troponin with CV risk factors and severity and complexity of coronary artery disease remains unknown. We assessed the predictors of peak troponin in patients with acute coronary syndrome (ACS). This study aims to determine the predictors of peak troponin in ACS. Cardiac catheterization (CC) reports and electronic medical records from 2010 to 2013 were retrospectively reviewed. A total of 219 patients were eligible for the study. All major CV risk factors, comorbidities, laboratory data, CC indications, and coronary lesion characteristics were included. Univariate and multivariate regression analyses were done. On multivariate linear regression analysis, ST-elevation myocardial infarction (p = 0.001, β = 65.16) and increasing synergy between percutaneous coronary intervention with Taxus and cardiac surgery (SYNTAX) score (p = 0.002, β = 1.15) were associated with higher peak troponin. The Pearson correlation between SYNTAX score and peak troponin was r = 0.257, p = 0.001. History of daily aspirin use was associated with lower peak troponin (p = 0.002, β = −24.32). Prior statin use (p = 0.321, β = −8.98) and the presence of CV risk factors were not associated with peak troponin. Coronary artery disease severity and complexity, urgency of CC, and prior aspirin use are associated with peak troponin levels in ACS. Our findings may help predict patient population with ACS who would be at a greater risk for short- and long-term CV morbidity and mortality due to elevated peak troponin. PMID:26900312

  5. A Proteomics Analysis of the Effects of Chronic Hemiparetic Stroke on Troponin T Expression in Human Vastus Lateralis

    PubMed Central

    Rabek, Jeffrey P.; Hafer-Macko, Charlene E.; Amaning, James K.; DeFord, James H.; Dimayuga, Vincent L.; Madsen, Mark A.; Macko, Richard F.

    2009-01-01

    Stroke disability is attributed to upper motor neuron deficits resulting from ischemic brain injury. We have developed proteome maps of the Vastus lateralis to examine the effects of ischemic brain injury on paretic skeletal muscle myofilament proteins. Proteomics analyses from seven hemiparetic stroke patients have detected a decrease of three troponin T isoforms in the paretic muscle suggesting that myosin–actin interactions may be attenuated. We propose that ischemic brain injury may prevent troponin T participation in complex formation thereby affecting the protein interactions associated with excitation–contraction coupling. We have also detected a novel skeletal troponin T isoform that has a C-terminal variation. Our data suggest that the decreased slow troponin T isoform pools in the paretic limb may contribute to the gait deficit after stroke. The complexity of the neurological deficit on Vastus lateralis is suggested by the multiple changes in proteins detected by our proteomics mapping. PMID:19447848

  6. Troponin C Mutations Partially Stabilize the Active State of Regulated Actin and Fully Stabilize the Active State When Paired with Δ14 TnT.

    PubMed

    Baxley, Tamatha; Johnson, Dylan; Pinto, Jose R; Chalovich, Joseph M

    2017-06-13

    Striated muscle contraction is regulated by the actin-associated proteins tropomyosin and troponin. The extent of activation of myosin ATPase activity is lowest in the absence of both Ca 2+ and activating cross-bridges (i.e., S1-ADP or rigor S1). Binding of activating species of myosin to actin at a saturating Ca 2+ concentration stabilizes the most active state (M state) of the actin-tropomyosin-troponin complex (regulated actin). Ca 2+ binding alone produces partial stabilization of the active state. The extent of stabilization at a saturating Ca 2+ concentration depends on the isoform of the troponin subunits, the phosphorylation state of troponin, and, in the case of cardiac muscle, the presence of hypertrophic cardiomyopathy-producing mutants of troponin T and troponin I. Cardiac dysfunction is also associated with mutations of troponin C (TnC). Troponin C mutants A8V, C84Y, and D145E increase the Ca 2+ sensitivity of ATPase activity. We show that these mutants change the distribution of regulated actin states. The A8V and C84Y TnC mutants decreased the inactive B state distribution slightly at low Ca 2+ concentrations, but the D145E mutants had no effect on that state. All TnC mutants increased the level of the active M state compared to that of the wild type, at a saturating Ca 2+ concentration. Troponin complexes that contained two mutations that stabilize the active M state, A8V TnC and Δ14 TnT, appeared to be completely in the active state in the presence of only Ca 2+ . Because Ca 2+ gives full activation, in this situation, troponin must be capable of positioning tropomyosin in the active M state without the need for rigor myosin binding.

  7. Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI.

    PubMed

    Kondo, Takashi; Kobayashi, Daisuke; Mochizuki, Maki; Asanuma, Kouichi; Takahashi, Satoshi

    2017-01-01

    Background Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. However, differences in measured values between these new reagents and previously used reagents have not been well studied. In this study, we aimed to compare the values between ARCHITECT High-Sensitive Troponin I ST (newly developed reagents), ARCHITECT Troponin I ST and STACIA CLEIA cardiac troponin I (two previously developed reagent kits). Methods Gel filtration high-performance liquid chromatography was used to analyse the causes of differences in measured values. Results The measured values differed between ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cardiac troponin I reagents (r = 0.82). Cross-reactivity tests using plasma with added skeletal-muscle troponin I resulted in higher reactivity (2.17-3.03%) for the STACIA CLEIA cardiac troponin I reagents compared with that for the ARCHITECT High-Sensitive Troponin I ST reagents (less than 0.014%). In addition, analysis of three representative samples using gel filtration high-performance liquid chromatography revealed reagent-specific differences in the reactivity against each cardiac troponin I complex; this could explain the differences in values observed for some of the samples. Conclusion The newly developed ARCHITECT High-Sensitive Troponin I ST reagents were not affected by the presence of skeletal-muscle troponin I in the blood and may be useful for routine examinations.

  8. Coupled expression of troponin T and troponin I isoforms in single skeletal muscle fibers correlates with contractility.

    PubMed

    Brotto, Marco A; Biesiadecki, Brandon J; Brotto, Leticia S; Nosek, Thomas M; Jin, Jian-Ping

    2006-02-01

    Striated muscle contraction is powered by actin-activated myosin ATPase. This process is regulated by Ca(2+) via the troponin complex. Slow- and fast-twitch fibers of vertebrate skeletal muscle express type I and type II myosin, respectively, and these myosin isoenzymes confer different ATPase activities, contractile velocities, and force. Skeletal muscle troponin has also diverged into fast and slow isoforms, but their functional significance is not fully understood. To investigate the expression of troponin isoforms in mammalian skeletal muscle and their functional relationship to that of the myosin isoforms, we concomitantly studied myosin, troponin T (TnT), and troponin I (TnI) isoform contents and isometric contractile properties in single fibers of rat skeletal muscle. We characterized a large number of Triton X-100-skinned single fibers from soleus, diaphragm, gastrocnemius, and extensor digitorum longus muscles and selected fibers with combinations of a single myosin isoform and a single class (slow or fast) of the TnT and TnI isoforms to investigate their role in determining contractility. Types IIa, IIx, and IIb myosin fibers produced higher isometric force than that of type I fibers. Despite the polyploidy of adult skeletal muscle fibers, the expression of fast or slow isoforms of TnT and TnI is tightly coupled. Fibers containing slow troponin had higher Ca(2+) sensitivity than that of the fast troponin fibers, whereas fibers containing fast troponin showed a higher cooperativity of Ca(2+) activation than that of the slow troponin fibers. These results demonstrate distinct but coordinated regulation of troponin and myosin isoform expression in skeletal muscle and their contribution to the contractile properties of muscle.

  9. Coupled expression of troponin T and troponin I isoforms in single skeletal muscle fibers correlates with contractility

    PubMed Central

    BROTTO, MARCO A.; BIESIADECKI, BRANDON J.; BROTTO, LETICIA S.; NOSEK, THOMAS M; JIN, J.-P.

    2005-01-01

    (Summary) Brotto, Marco A., Brandon J. Biesiadecki, Leticia S. Brotto, Thomas M. Nosek, and J.-P. Jin. Striated muscle contraction is powered by actin-activated myosin ATPase. This process is regulated by Ca2+ via the troponin complex. Slow and fast twitch fibers of vertebrate skeletal muscle express type I and type II myosin, respectively, and these myosin isoenzymes confer different ATPase activities, contractile velocities and force. Skeletal muscle troponin has also diverged into fast and slow isoforms, but their functional significance is not fully understood. To investigate the expression of troponin isoforms in mammalian skeletal muscle and their functional relationship to that of the myosin isoforms, we concomitantly studied myosin and troponin T (TnT) and troponin I (TnI) isoform contents and isometric contractile properties in single fibers of rat skeletal muscle. We characterized a large number of Triton skinned single fibers from soleus, diaphragm, gastrocnemius and extensor digitorum longus muscles and selected fibers with combinations of a single myosin isoform and a single class (slow or fast) of TnT and TnI isoform to investigate their role in determining contractility. Type IIa, IIx and IIb myosin fibers produced higher isometric force than that of type I fibers. Despite the polyploidy of adult skeletal muscle fibers, the expression of fast or slow isoforms of TnT and TnI is tightly coupled. Fibers containing slow troponin had higher Ca2+ sensitivity than that of the fast troponin fibers, while fibers containing fast troponin showed a higher cooperativity of Ca2+ activation than that of the slow troponin fibers. The results demonstrate distinctive, but coordinated, regulation of troponin and myosin isoform expression in skeletal muscle and their contribution to the contractile properties. PMID:16192301

  10. Troponin T3 expression in skeletal and smooth muscle is required for growth and postnatal survival: characterization of Tnnt3(tm2a(KOMP)Wtsi) mice.

    PubMed

    Ju, Yawen; Li, Jie; Xie, Chao; Ritchlin, Christopher T; Xing, Lianping; Hilton, Matthew J; Schwarz, Edward M

    2013-09-01

    The troponin complex, which consists of three regulatory proteins (troponin C, troponin I, and troponin T), is known to regulate muscle contraction in skeletal and cardiac muscle, but its role in smooth muscle remains controversial. Troponin T3 (TnnT3) is a fast skeletal muscle troponin believed to be expressed only in skeletal muscle cells. To determine the in vivo function and tissue-specific expression of Tnnt3, we obtained the heterozygous Tnnt3+/flox/lacZ mice from Knockout Mouse Project (KOMP) Repository. Tnnt3(lacZ/+) mice are smaller than their WT littermates throughout development but do not display any gross phenotypes. Tnnt3(lacZ/lacZ) embryos are smaller than heterozygotes and die shortly after birth. Histology revealed hemorrhagic tissue in Tnnt3(lacZ/lacZ) liver and kidney, which was not present in Tnnt3(lacZ/+) or WT, but no other gross tissue abnormalities. X-gal staining for Tnnt3 promoter-driven lacZ transgene expression revealed positive staining in skeletal muscle and diaphragm and smooth muscle cells located in the aorta, bladder, and bronchus. Collectively, these findings suggest that troponins are expressed in smooth muscle and are required for normal growth and breathing for postnatal survival. Moreover, future studies with this mouse model can explore TnnT3 function in adult muscle function using the conditional-inducible gene deletion approach Copyright © 2013 Wiley Periodicals, Inc.

  11. Hypertrophic Cardiomyopathy Cardiac Troponin C Mutations Differentially Affect Slow Skeletal and Cardiac Muscle Regulation

    PubMed Central

    Veltri, Tiago; Landim-Vieira, Maicon; Parvatiyar, Michelle S.; Gonzalez-Martinez, David; Dieseldorff Jones, Karissa M.; Michell, Clara A.; Dweck, David; Landstrom, Andrew P.; Chase, P. Bryant; Pinto, Jose R.

    2017-01-01

    Mutations in TNNC1—the gene encoding cardiac troponin C (cTnC)—that have been associated with hypertrophic cardiomyopathy (HCM) and cardiac dysfunction may also affect Ca2+-regulation and function of slow skeletal muscle since the same gene is expressed in both cardiac and slow skeletal muscle. Therefore, we reconstituted rabbit soleus fibers and bovine masseter myofibrils with mutant cTnCs (A8V, C84Y, E134D, and D145E) associated with HCM to investigate their effects on contractile force and ATPase rates, respectively. Previously, we showed that these HCM cTnC mutants, except for E134D, increased the Ca2+ sensitivity of force development in cardiac preparations. In the current study, an increase in Ca2+ sensitivity of isometric force was only observed for the C84Y mutant when reconstituted in soleus fibers. Incorporation of cTnC C84Y in bovine masseter myofibrils reduced the ATPase activity at saturating [Ca2+], whereas, incorporation of cTnC D145E increased the ATPase activity at inhibiting and saturating [Ca2+]. We also tested whether reconstitution of cardiac fibers with troponin complexes containing the cTnC mutants and slow skeletal troponin I (ssTnI) could emulate the slow skeletal functional phenotype. Reconstitution of cardiac fibers with troponin complexes containing ssTnI attenuated the Ca2+ sensitization of isometric force when cTnC A8V and D145E were present; however, it was enhanced for C84Y. In summary, although the A8V and D145E mutants are present in both muscle types, their functional phenotype is more prominent in cardiac muscle than in slow skeletal muscle, which has implications for the protein-protein interactions within the troponin complex. The C84Y mutant warrants further investigation since it drastically alters the properties of both muscle types and may account for the earlier clinical onset in the proband. PMID:28473771

  12. Detection of a troponin I-like protein in non-striated muscle of the tardigrades (water bears)

    PubMed Central

    Obinata, Takashi; Ono, Kanako

    2011-01-01

    Tardigrades, also known as water bears, have somatic muscle fibers that are responsible for movement of their body and legs. These muscle fibers contain thin and thick filaments in a non-striated pattern. However, the regulatory mechanism of muscle contraction in tardigrades is unknown. In the absence of extensive molecular and genomic information, we detected a protein of 31 kDa in whole lysates of tardigrades that cross-reacted with the antibody raised against nematode troponin I (TnI). TnI is a component of the troponin complex that regulates actin-myosin interaction in a Ca2+-dependent and actin-linked manner. This TnI-like protein was co-extracted with actin in a buffer containing ATP and EGTA, which is known to induce relaxation of a troponin-regulated contractile system. The TnI-like protein was specifically expressed in the somatic muscle fibers in adult animals and partially co-localized with actin filaments in a non-striated manner. Interestingly, the pharyngeal muscle did not express this protein. These observations suggest that the non-striated somatic muscle of tardigrades has an actin-linked and troponin-regulated system for muscle contraction. PMID:21866271

  13. Cardiac differentiation of cardiosphere-derived cells in scaffolds mimicking morphology of the cardiac extracellular matrix.

    PubMed

    Xu, Yanyi; Patnaik, Sourav; Guo, Xiaolei; Li, Zhenqing; Lo, Wilson; Butler, Ryan; Claude, Andrew; Liu, Zhenguo; Zhang, Ge; Liao, Jun; Anderson, Peter M; Guan, Jianjun

    2014-08-01

    Stem cell therapy has the potential to regenerate heart tissue after myocardial infarction (MI). The regeneration is dependent upon cardiac differentiation of the delivered stem cells. We hypothesized that timing of the stem cell delivery determines the extent of cardiac differentiation as cell differentiation is dependent on matrix properties such as biomechanics, structure and morphology, and these properties in cardiac extracellular matrix (ECM) continuously vary with time after MI. In order to elucidate the relationship between ECM properties and cardiac differentiation, we created an in vitro model based on ECM-mimicking fibers and a type of cardiac progenitor cell, cardiosphere-derived cells (CDCs). A simultaneous fiber electrospinning and cell electrospraying technique was utilized to fabricate constructs. By blending a highly soft hydrogel with a relatively stiff polyurethane and modulating fabrication parameters, tissue constructs with similar cell adhesion property but different global modulus, single fiber modulus, fiber density and fiber alignment were achieved. The CDCs remained alive within the constructs during a 1week culture period. CDC cardiac differentiation was dependent on the scaffold modulus, fiber volume fraction and fiber alignment. Two constructs with relatively low scaffold modulus, ∼50-60kPa, most significantly directed the CDC differentiation into mature cardiomyocytes as evidenced by gene expressions of cardiac troponin T (cTnT), calcium channel (CACNA1c) and cardiac myosin heavy chain (MYH6), and protein expressions of cardiac troponin I (cTnI) and connexin 43 (CX43). Of these two low-modulus constructs, the extent of differentiation was greater for lower fiber alignment and higher fiber volume fraction. These results suggest that cardiac ECM properties may have an effect on cardiac differentiation of delivered stem cells. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. Familial Hypertrophic Cardiomyopathy Related Cardiac Troponin C L29Q Mutation Alters Length-Dependent Activation and Functional Effects of Phosphomimetic Troponin I*

    PubMed Central

    Li, Alison Y.; Stevens, Charles M.; Liang, Bo; Rayani, Kaveh; Little, Sean; Davis, Jonathan; Tibbits, Glen F.

    2013-01-01

    The Ca2+ binding properties of the FHC-associated cardiac troponin C (cTnC) mutation L29Q were examined in isolated cTnC, troponin complexes, reconstituted thin filament preparations, and skinned cardiomyocytes. While higher Ca2+ binding affinity was apparent for the L29Q mutant in isolated cTnC, this phenomenon was not observed in the cTn complex. At the level of the thin filament in the presence of phosphomimetic TnI, L29Q cTnC further reduced the Ca2+ affinity by 27% in the steady-state measurement and increased the Ca2+ dissociation rate by 20% in the kinetic studies. Molecular dynamics simulations suggest that L29Q destabilizes the conformation of cNTnC in the presence of phosphomimetic cTnI and potentially modulates the Ca2+ sensitivity due to the changes of the opening/closing equilibrium of cNTnC. In the skinned cardiomyocyte preparation, L29Q cTnC increased Ca2+ sensitivity in a highly sarcomere length (SL)-dependent manner. The well-established reduction of Ca2+ sensitivity by phosphomimetic cTnI was diminished by 68% in the presence of the mutation and it also depressed the SL-dependent increase in myofilament Ca2+ sensitivity. This might result from its modified interaction with cTnI which altered the feedback effects of cross-bridges on the L29Q cTnC-cTnI-Tm complex. This study demonstrates that the L29Q mutation alters the contractility and the functional effects of the phosphomimetic cTnI in both thin filament and single skinned cardiomyocytes and importantly that this effect is highly sarcomere length dependent. PMID:24260207

  15. The concerted movement of the switch region of Troponin I in cardiac muscle thin filaments as tracked by conventional and pulsed (DEER) EPR.

    PubMed

    Potluri, Phani R; Chamoun, Jean; Cooke, James A; Badr, Myriam; Guse, Joanna A; Rayes, Roni; Cordina, Nicole M; McCamey, Dane; Fajer, Piotr G; Brown, Louise J

    2017-12-01

    The absence of a crystal structure of the calcium free state of the cardiac isoform of the troponin complex has hindered our understanding of how the simple binding of Ca 2+ triggers conformational changes in troponin which are then propagated to enable muscle contraction. Here we have used continuous wave (CW) and Double Electron-Electron Resonance (DEER) pulsed EPR spectroscopy to measure distances between TnI and TnC to track the movement of the functionally important regulatory 'switch' region of cardiac Tn. Spin labels were placed on the switch region of Troponin I and distances measured to Troponin C. Under conditions of high Ca 2+ , the interspin distances for one set (TnI151/TnC84) were 'short' (9-10Å) with narrow distance distribution widths (3-8Å) indicating the close interaction of the switch region with the N-lobe of TnC. Additional spin populations representative of longer interspin distances were detected by DEER. These longer distance populations, which were ∼16-19Å longer than the short distance populations, possessed notably broader distance distribution widths (14-29Å). Upon Ca 2+ removal, the interspin population shifted toward the longer distances, indicating the release of the switch region from TnC and an overall increase in disorder for this region. Together, our results suggest that under conditions of low Ca 2+ , the close proximity of the TnI switch region to TnC in the cardiac isoform is necessary for promoting the interaction between the regulatory switch helix with the N-lobe of cardiac Troponin C, which, unlike the skeletal isoform, is largely in a closed conformation. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Cardiological aspects of carbon monoxide poisoning.

    PubMed

    Marchewka, Jakub; Gawlik, Iwona; Dębski, Grzegorz; Popiołek, Lech; Marchewka, Wojciech; Hydzik, Piotr

    2017-01-01

    The aim of this study was to assess cardiological manifestations of carbon monoxide (CO) poisoning. Background/introduction: Carbon monoxide intoxication is one of the most important toxicological causes of morbidity and mortality worldwide. Early clinical manifestation of CO poisoning is cardiotoxicity. We enrolled 75 patients (34 males and 41 females, mean age 37.6 ± 17.7 y/o) hospitalized due to CO poisoning. Laboratory tests including troponin I, blood pressure measurements, HR and electrocardiograms (ECG) were collected. Pach's scale scoring and grading system was used to establish severity of poisoning. Grade of poisoning is positively correlated with troponin I levels and systolic blood pressure. Moreover, troponin levels are significantly correlated with exposition time, lactates and are higher in tachycardiac, hypertensive and positive ECG subpopulations. COHb levels are indicative of exposure but do not correlate with grade of poisoning. The main cause of CO poisoning were bathroom heaters - 83%, only 11% of examined intoxicated population were equipped with CO detectors. Complex cardiological screening covering troponin levels, ECG, blood pressure and heart rate measurements as well as complete blood count with particular attention to platelet parameters should be performed in each case where CO intoxication is suspected. More emphasis on education on CO poisoning is needed.

  17. The Ca2+ sensitizer CK‐2066260 increases myofibrillar Ca2+ sensitivity and submaximal force selectively in fast skeletal muscle

    PubMed Central

    Cheng, Arthur J.; Hartman, James J.; Hinken, Aaron C.; Lee, Ken; Durham, Nickie; Russell, Alan J.; Malik, Fady I.; Westerblad, Håkan; Jasper, Jeffrey R.

    2017-01-01

    Key points We report that the small molecule CK‐2066260 selectively slows the off‐rate of Ca2 + from fast skeletal muscle troponin, leading to increased myofibrillar Ca2 + sensitivity in fast skeletal muscle.Rodents dosed with CK‐2066260 show increased hindlimb muscle force and power in response to submaximal rates of nerve stimulation in situ.CK‐2066260 has no effect on free cytosolic [Ca2 +] during contractions of isolated muscle fibres.We conclude that fast skeletal muscle troponin sensitizers constitute a potential therapy to address an unmet need of improving muscle function in conditions of weakness and premature muscle fatigue. Abstract Skeletal muscle dysfunction occurs in many diseases and can lead to muscle weakness and premature muscle fatigue. Here we show that the fast skeletal troponin activator, CK‐2066260, counteracts muscle weakness by increasing troponin Ca2+ affinity, thereby increasing myofibrillar Ca2+ sensitivity. Exposure to CK‐2066260 resulted in a concentration‐dependent increase in the Ca2+ sensitivity of ATPase activity in isolated myofibrils and reconstituted hybrid sarcomeres containing fast skeletal muscle troponin C. Stopped‐flow experiments revealed a ∼2.7‐fold decrease in the Ca2+ off‐rate of isolated troponin complexes in the presence of CK‐2066260 (6 vs. 17 s−1 under control conditions). Isolated mouse flexor digitorum brevis fibres showed a rapidly developing, reversible and concentration‐dependent force increase at submaximal stimulation frequencies. This force increase was not accompanied by any changes in the free cytosolic [Ca2+] or its kinetics. CK‐2066260 induced a slowing of relaxation, which was markedly larger at 26°C than at 31°C and could be linked to the decreased Ca2+ off‐rate of troponin C. Rats dosed with CK‐2066260 showed increased hindlimb isometric and isokinetic force in response to submaximal rates of nerve stimulation in situ producing significantly higher absolute forces at low isokinetic velocities, whereas there was no difference in force at the highest velocities. Overall muscle power was increased and the findings are consistent with a lack of effect on crossbridge kinetics. In conclusion, CK‐2066260 acts as a fast skeletal troponin activator that may be used to increase muscle force and power in conditions of muscle weakness. PMID:27869319

  18. Structure of the inhibitory region of troponin by site directed spin labeling electron paramagnetic resonance

    PubMed Central

    Brown, Louise J.; Sale, Ken L.; Hills, Ron; Rouviere, Clement; Song, Likai; Zhang, Xiaojun; Fajer, Piotr G.

    2002-01-01

    Site-directed spin labeling EPR (SDSL-EPR) was used to determine the structure of the inhibitory region of TnI in the intact cardiac troponin ternary complex. Maeda and collaborators have modeled the inhibitory region of TnI (skeletal 96–112: the structural motif that communicates the Ca2+ signal to actin) as a kinked α-helix [Vassylyev, D., Takeda, S., Wakatsuki, S., Maeda, K. & Maeda, Y. (1998) Proc. Natl. Acad. Sci. USA 95, 4847–4852), whereas Trewhella and collaborators have proposed the same region to be a flexible β-hairpin [Tung, C. S., Wall, M. E., Gallagher, S. C. & Trewhella, J. (2000) Protein Sci. 9, 1312–1326]. To distinguish between the two models, residues 129–145 of cardiac TnI were mutated sequentially to cysteines and labeled with the extrinsic spin probe, MTSSL. Sequence-dependent solvent accessibility was measured as a change in power saturation of the spin probe in the presence of the relaxation agent. In the ternary complex, the 129–137 region followed a pattern characteristic of a regular 3.6 residues/turn α-helix. The following region, residues 138–145, showed no regular pattern in solvent accessibility. Measurements of 4 intradomain distances within the inhibitory sequence, using dipolar EPR, were consistent with an α-helical structure. The difference in side-chain mobility between the ternary (C⋅I⋅T) and binary (C⋅I) complexes revealed a region of interaction of TnT located at the N-terminal end of the inhibitory sequence, residues 130–135. The above findings for the troponin complex in solution do not support either of the computational models of the binary complex; however, they are in very good agreement with a preliminary report of the x-ray structure of the cardiac ternary complex [Takeda, S. Yamashita, A., Maeda, K. & Maeda, Y. (2002) Biophys. J. 82, 832]. PMID:12239350

  19. Role of Admission Troponin-T and Serial Troponin-T Testing in Predicting Outcomes in Severe Sepsis and Septic Shock.

    PubMed

    Vallabhajosyula, Saraschandra; Sakhuja, Ankit; Geske, Jeffrey B; Kumar, Mukesh; Poterucha, Joseph T; Kashyap, Rahul; Kashani, Kianoush; Jaffe, Allan S; Jentzer, Jacob C

    2017-09-09

    Troponin-T elevation is seen commonly in sepsis and septic shock patients admitted to the intensive care unit. We sought to evaluate the role of admission and serial troponin-T testing in the prognostication of these patients. This was a retrospective cohort study from 2007 to 2014 on patients admitted to the intensive care units at the Mayo Clinic with severe sepsis and septic shock. Elevated admission troponin-T and significant delta troponin-T were defined as ≥0.01 ng/mL and ≥0.03 ng/mL in 3 hours, respectively. The primary outcome was in-hospital mortality. Secondary outcomes included 1-year mortality and lengths of stay. During this 8-year period, 944 patients met the inclusion criteria with 845 (90%) having an admission troponin-T ≥0.01 ng/mL. Serial troponin-T values were available in 732 (78%) patients. Elevated admission troponin-T was associated with older age, higher baseline comorbidity, and severity of illness, whereas significant delta troponin-T was associated with higher severity of illness. Admission log 10 troponin-T was associated with unadjusted in-hospital (odds ratio 1.6; P =0.003) and 1-year mortality (odds ratio 1.3; P =0.04), but did not correlate with length of stay. Elevated delta troponin-T and log 10 delta troponin-T were not significantly associated with any of the primary or secondary outcomes. Admission log 10 troponin-T remained an independent predictor of in-hospital mortality (odds ratio 1.4; P =0.04) and 1-year survival (hazard ratio 1.3; P =0.008). In patients with sepsis and septic shock, elevated admission troponin-T was associated with higher short- and long-term mortality. Routine serial troponin-T testing did not add incremental prognostic value in these patients. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Prognostic prediction of troponins in cardiac myxoma: case study with literature review

    PubMed Central

    Yuan, Shi-Min

    2015-01-01

    Objective It was supposed that troponins in cardiac myxoma patients might be in a same fashion as in the conditions without myocardial injury. In order to verify this hypothesis, troponins in cardiac myxoma patients were discussed by presenting a comprehensive retrieval of the literature with incorporating the information of a recent patient. Methods Postoperative detections of troponin I, creatine kinase isoenzyme MB (CK-MB) and N-terminal pro-B-type natriuretic peptide revealed elevated troponin I and CK-MB and normal N-terminal pro-B-type natriuretic peptide. Postoperative troponin I and CK-MB shared a same trend, reaching a peak value at postoperative hour 2, gradually decreased on postoperative day 1, and reached a plateau on postoperative days 7 and 13. A significant correlation could be noted between the postoperative values of the two indicators (Y=0.0714X + 0.6425, r2=0.9111, r=0.9545, P=0.0116). No significant linear correlation between troponin I and N-terminal pro-B-type natriuretic peptide were found. Literature review of troponins in cardiac myxoma patients revealed the uncomplicated patients had a normal or only slightly elevated troponin before open heart surgery. However, the complicated patients (with cerebral or cardiac events) showed a normal preoperative troponin in 3 (23.1%) and an elevated troponin in 10 (76.9%) patients (χ2=7.54, P=0.0169, Fisher's exact test). The overall quantitative result of troponin I was 2.45±2.53 µg/L, and that of troponin T was 3.10±4.29 mg/L, respectively. Conclusion Troponins are not necessarily elevated in patients with a cardiac myxoma without coronary syndrome. By contrast, patients with a cardiac myxoma with an elevated troponin may herald the presence of an associated coronary event. An old cerebral infarct does not necessarily cause an elevation of troponin or B-type natriuretic peptide, or new neurological events, but might lead to a delayed awakening. PMID:26107461

  1. Cardiac Troponins and Autoimmunity: their role in the pathogenesis of myocarditis and of heart failure

    PubMed Central

    Kaya, Ziya; Katus, Hugo A.; Rose, Noel R.

    2010-01-01

    Despite the widespread use of cardiac troponins as biomarkers for the diagnosis and quantitation of cardiac injury, the effect of troponin release and a possible autoimmune response to the troponins is unknown. Other investigators reported that programmed cell death – 1 (PD-1) – receptor deficient mice developed severe cardiomyopathy with autoantibodies to troponin I. We found that immunization of genetically susceptible mice with troponin I but not troponin T induced a robust autoimmune response leading to marked inflammation and fibrosis in the myocardium. At later times, antibodies to cardiac myosin were detected in troponin – immunized mice. The severity of inflammation correlated with expression of chemokines RANTES, MIP-2, IP-10 and MCD-1 in the myocardium. Prior immunization with troponin I increased the severity of experimental infarctions, indicating that an autoimmune response to troponin I aggravates acute cardiac damage. Cardiac inflammation, fibrosis and functional impairment were transferred from immunized to naive recipients by CD4+ T cells, and the cytokine profile suggested both a Th2 and Th17 profile in A/J mice. Finally we identified an 18-mer of troponin I containing an immuno-dominant epitope. PMID:19446498

  2. Interpretation of positive troponin results among patients with and without myocardial infarction

    PubMed Central

    Tecson, Kristen M.; Arnold, William; Barrett, Tyler; Birkhahn, Robert; Daniels, Lori B.; DeFilippi, Christopher; Headden, Gary; Peacock, W. Frank; Reed, Michael; Singer, Adam J.; Schussler, Jeffrey M.; Smith, Stephen; Than, Martin P.

    2017-01-01

    Measuring cardiac troponins is integral to diagnosing acute myocardial infarction (AMI); however, troponins may be elevated without AMI, and the use of multiple different assays confounds comparisons. We considered characteristics and serial troponin values in emergency department chest pain patients with and without AMI to interpret troponin excursions. We compared serial troponin in 124 AMI and non-AMI patients from the observational Performance of Triage Cardiac Markers in the Clinical Setting (PEARL) study who presented with chest pain and had at least one troponin value exceeding the 99th percentile of normal. Because 8 assays were used during data collection, we employed a method of scaling the troponin value to the corresponding assay's 99th percentile upper reference limit to standardize the results. In 81 AMI patients, 96% had elevated troponin at the first test following initial elevation, compared to 73% of the 43 non-AMI patients (P < 0.001). Scaling troponin to the 99th percentile of normal yielded a median value that was 4.8 [2.2, 14.1] times higher than the 99th percentile cutpoint among AMI patients, compared to 2.3 [1.5, 6.5] times higher among non-AMI patients (P = 0.04). The rise in serial scaled troponin values distinguished the AMI patients. Scaling to the 99th percentile was useful for comparing troponin when different assays were utilized. PMID:28127121

  3. Comparative studies on troponin, a Ca²⁺-dependent regulator of muscle contraction, in striated and smooth muscles of protochordates.

    PubMed

    Obinata, Takashi; Sato, Naruki

    2012-01-01

    Troponin is well known as a Ca(2+)-dependent regulator of striated muscle contraction and it has been generally accepted that troponin functions as an inhibitor of muscle contraction or actin-myosin interaction at low Ca(2+) concentrations, and Ca(2+) at higher concentrations removes the inhibitory action of troponin. Recently, however, troponin became detectable in non-striated muscles of several invertebrates and in addition, unique troponin that functions as a Ca(2+)-dependent activator of muscle contraction has been detected in protochordate animals, although troponin in vertebrate striated muscle is known as an inhibitor of the contraction in the absence of a Ca(2+). Further studies on troponin in invertebrate muscle, especially in non-striated muscle, would provide new insight into the evolution of regulatory systems for muscle contraction and diverse function of troponin and related proteins. The methodology used for preparation and characterization of functional properties of protochordate striated and smooth muscles will be helpful for further studies of troponin in other invertebrate animals. Copyright © 2011. Published by Elsevier Inc.

  4. Cardiac muscle activation blunted by a mutation to the regulatory component, troponin T.

    PubMed

    Kobayashi, Minae; Debold, Edward P; Turner, Matthew A; Kobayashi, Tomoyoshi

    2013-09-06

    The striated muscle thin filament comprises actin, tropomyosin, and troponin. The Tn complex consists of three subunits, troponin C (TnC), troponin I (TnI), and troponin T (TnT). TnT may serve as a bridge between the Ca(2+) sensor (TnC) and the actin filament. In the short helix preceding the IT-arm region, H1(T2), there are known dilated cardiomyopathy-linked mutations (among them R205L). Thus we hypothesized that there is an element in this short helix that plays an important role in regulating the muscle contraction, especially in Ca(2+) activation. We mutated Arg-205 and several other amino acid residues within and near the H1(T2) helix. Utilizing an alanine replacement method to compare the effects of the mutations, the biochemical and mechanical impact on the actomyosin interaction was assessed by solution ATPase activity assay, an in vitro motility assay, and Ca(2+) binding measurements. Ca(2+) activation was markedly impaired by a point mutation of the highly conserved basic residue R205A, residing in the short helix H1(T2) of cTnT, whereas the mutations to nearby residues exhibited little effect on function. Interestingly, rigor activation was unchanged between the wild type and R205A TnT. In addition to the reduction in Ca(2+) sensitivity observed in Ca(2+) binding to the thin filament, myosin S1-ADP binding to the thin filament was significantly affected by the same mutation, which was also supported by a series of S1 concentration-dependent ATPase assays. These suggest that the R205A mutation alters function through reduction in the nature of cooperative binding of S1.

  5. Resource utilization and outcome among patients with selective versus nonselective troponin testing.

    PubMed

    Campbell, Alex R; Rodriguez, Alexander J; Larson, David M; Strauss, Craig E; Garberich, Ross F; Partridge, Matthew F; Henry, Timothy D; Sharkey, Scott W

    2018-05-01

    In patients with suspected acute coronary syndrome (ACS), troponin testing is effective for diagnosis and prognosis. Troponin testing has now expanded to include patients without suspected ACS. This nonselective troponin testing has unknown consequences for resource utilization and outcome. Therefore, we examined selective versus nonselective troponin testing with respect to patient characteristics, resource utilization, and outcome. This retrospective 1-year study included all patients with troponin testing at a U.S. emergency department. Testing was classified as selective (ACS) or nonselective (non-ACS) based on admission ICD-9 codes. Troponin upper reference limit (URL) was ≥99th percentile. Among 47,053 patients, troponin was measured in 9109 (19%) of whom 5764 were hospitalized. Admission diagnosis was non-ACS in 4427 (77%) and ACS in 1337 (23%). Non-ACS patients were older, 71±17 versus 65±16 years, with longer hospital stay, 77 versus 32 h, and greater 1-year mortality 22% versus 6.7%; P<.001. In patients with troponin ≥URL, revascularization was performed in 64 (4.7%) of non-ACS versus 213 (48%) of ACS; P<.001. In patients with troponin 80% of the non-ACS population CONCLUSIONS: Contemporary troponin testing is frequently nonselective. The non-ACS and ACS populations differ significantly regarding clinical characteristics, revascularization rates, and outcomes. Troponin elevation is a powerful predictor of 1-year mortality in non-ACS, this association reveals an opportunity for risk stratification and targeted therapy. In patients with suspected acute coronary syndrome (ACS), troponin testing is effective for diagnosis and prognosis. However, troponin testing has now expanded to include patients without suspected ACS. This nonselective troponin testing has unknown consequences for hospital resource utilization and patient outcome. Our findings demonstrate contemporary troponin testing is largely nonselective (77% of testing was performed in patients without acute coronary syndrome). In comparison to patients with acute coronary syndrome, those with non-acute coronary syndrome are older, with longer hospital stay, lower revascularization rates, and greater 1-year mortality. Troponin elevation identifies a high-risk population in both acute coronary syndrome and non-acute coronary syndrome populations, yet effective treatment for the latter is lacking. Copyright © 2018. Published by Elsevier Inc.

  6. Long-timescale molecular dynamics simulations elucidate the dynamics and kinetics of exposure of the hydrophobic patch in troponin C.

    PubMed

    Lindert, Steffen; Kekenes-Huskey, Peter M; McCammon, J Andrew

    2012-10-17

    Troponin (Tn) is an important regulatory protein in the thin-filament complex of cardiomyocytes. Calcium binding to the troponin C (TnC) subunit causes a change in its dynamics that leads to the transient opening of a hydrophobic patch on TnC's surface, to which a helix of another subunit, troponin I (TnI), binds. This process initiates contraction, making it an important target for studies investigating the detailed molecular processes that underlie contraction. Here we use microsecond-timescale Anton molecular dynamics simulations to investigate the dynamics and kinetics of the opening transition of the TnC hydrophobic patch. Free-energy differences for opening are calculated for wild-type Ca(2+)-bound TnC (∼8 kcal/mol), V44Q Ca(2+)-bound TnC (3.2 kcal/mol), E40A Ca(2+)-bound TnC (∼12 kcal/mol), and wild-type apo TnC (∼20 kcal/mol). These results suggest that the mutations have a profound impact on the frequency with which the hydrophobic patch presents to TnI. In addition, these simulations corroborate that cardiac wild-type TnC does not open on timescales relevant to contraction without calcium being bound. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. Troponin I levels from donors accepted for pediatric heart transplantation do not predict recipient graft survival.

    PubMed

    Lin, Kimberly Y; Sullivan, Patrick; Salam, Abdul; Kaufman, Beth; Paridon, Stephen; Hanna, Brian D; Spray, Thomas L; Weber, Janice; Shaddy, Robert

    2011-08-01

    Troponin I is often obtained during the evaluation of a potential transplant donor heart. It is not clear whether elevations in donor troponin I levels predict adverse outcomes and should thus preclude acceptance of a donor heart. This study examined whether troponin I levels from donors accepted for pediatric heart transplantation predicted graft failure. Deidentified data on heart transplants performed in recipients aged < 21 years between April 2007 and April 2009 was provided by the Organ Procurement and Transplantation Network. Donor troponin I level and recipient outcomes, including survival without retransplantation (graft survival), were examined for statistical correlation. Overall graft survival in 839 heart transplants was 81% at 2 years. At least 1 troponin I level was recorded in 657 donors before transplant, with a median value of 0.1 ng/ml (range, 0-50 ng/ml). Troponin I level and graft status were not correlated (p = 0.74). A receiver operating characteristic curve showed no association between troponin I and graft status (area under the curve, 0.51; p = 0.98). Graft survival did not differ significantly (p = 0.60) among quartiles of troponin I levels (<0.04, 0.04-<0.1, 0.1-<0.35, ≥ 0.35 ng/ml). A troponin I level ≥ 1 ng/ml was found in 74 transplanted donor hearts; graft survival was not associated with troponin I ≥ 1 (80%) vs < 1 (80%) at 2 years (p = 0.93). Troponin I values were not associated with post-transplant hospital length of stay (r = -0.06; p = 0.10). In donor hearts accepted for pediatric heart transplantation, troponin I elevation before procurement is not associated with increased graft failure. The significance of elevated troponin I levels, which occurs in many heart donors, remains unclear and should therefore be considered in the context of other clinical information. Copyright © 2011 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Troponin and Anti-Troponin Autoantibody Levels in Patients with Ventricular Noncompaction

    PubMed Central

    Erer, Hatice Betül; Güvenç, Tolga Sinan; Kemik, Ahu Sarbay; Yılmaz, Hale Yaka; Kul, Şeref; Altay, Servet; Sayar, Nurten; Kaya, Yüksel; Eren, Mehmet

    2013-01-01

    Ventricular hypertrabeculation/noncompaction is a morphologic and functional anomaly of myocardium characterized by prominent trabeculae accompanied by deep recessus. Dilated cardiomyopathy with left ventricular failure is observed in these patients, while the cause or pathophysiologic nature of this complication is not known. Anti-troponin antibodies are formed against circulating cardiac troponins after an acute coronary event or conditions associated with chronic myocyte necrosis, such as dilated cardiomyopathy. In present study, we aimed to investigate cardiac troponins and anti troponin autoantibodies in ventricular noncompaction/hypertrabeculation patients with/without reduced ejection fraction. A total of 50 patients with ventricular noncompaction and 23 healthy volunteers were included in this study. Noncompaction/hypertrabeculation was diagnosed with two-dimensional echocardiography using appropriate criteria. Depending on ejection fraction, patients were grouped into noncompaction with preserved EF (LVEF >50%, n = 24) and noncompaction with reduced EF (LVEF <35%, n = 26) groups. Troponin I, troponin T, anti-troponin I IgM and anti-troponin T IgM were measured with sandwich immunoassay method using a commercially available kit. Patients with noncompaction had significantly higher troponin I (28.98±9.21 ng/ml in NCNE group and 28.11±10.42 ng/ml in NCLE group), troponin T (22.17±6.97 pg/ml in NCNE group and 22.78±7.76 pg/ml in NCLE group) and antitroponin I IgM (1.92±0.43 µg/ml in NCNE group and 1.79±0.36 µg/ml in NCLE group) levels compared to control group, while antitroponin T IgM and IgG were only elevated in patients with noncompaction and reduced EF (15.81±6.52 µg/ml for IgM and 16.46±6.25 µg/ml for IgG). Elevated cardiac troponins and anti-troponin I autoantibodies were observed in patients with noncompaction preceding the decline in systolic function and could indicate ongoing myocardial damage in these patients. PMID:23469039

  9. Troponin concentrations for stratification of patients with acute coronary syndromes in relation to therapeutic efficacy of tirofiban. PRISM Study Investigators. Platelet Receptor Inhibition in Ischemic Syndrome Management.

    PubMed

    Heeschen, C; Hamm, C W; Goldmann, B; Deu, A; Langenbrink, L; White, H D

    1999-11-20

    A major challenge for physicians is to identify patients with acute coronary syndromes who may benefit from treatment with glycoprotein-IIb/IIIa-receptor antagonists. We investigated whether troponin concentrations can be used to stratify patients for benefit from treatment with tirofiban. We enrolled 2222 patients of the Platelet Receptor Inhibition in Ischemic Syndrome Management study with coronary artery disease and who had had chest pain in the previous 24 h. All patients received aspirin and were randomly assigned treatment with tirofiban or heparin. We took baseline measurements of troponin I and troponin T. We recorded death, myocardial infarction, or recurrent ischaemia after 48 h infusion treatment and at 7 days and 30 days. 629 (28.3%) patients had troponin I concentrations higher than the diagnostic threshold of 1.0 microg/L and 644 (29.0%) troponin T concentrations higher than 0.1 microg/L. 30-day event rates (death, myocardial infarction) were 13.0% for troponin-I-positive patients compared with 4.9% for troponin-I-negative patients (p<0.0001), and 13.7% compared wth 3.5% for troponin T (p<0.001). At 30 days, in troponin-I-positive patients, tirofiban had lowered the risk of death (adjusted hazard ratio 0.25 [95% CI 0.09-0.68], p=0.004) and myocardial infarction (0.37 [0.16-0.84], p=0.01). This benefit was seen in medically managed patients (0.30 [0.10-0.84], p=0.004) and those undergoing revascularisation (0.37 [0.15-0.93] p=0.02) after 48 h infusion treatment. By contrast, no treatment effect was seen for troponin-I-negative patients. Similar benefits were seen for troponin-T-positive patients. Troponin I and troponin T reliably identified high-risk patients with acute coronary syndromes, managed medically and by revascularisation, who would benefit from tirofiban.

  10. Troponin and exercise.

    PubMed

    Gresslien, T; Agewall, S

    2016-10-15

    Cardiac troponins are the preferred biomarkers in diagnostic of myocardial infarction, but these markers also can rise in response to exercise. Multiple studies have assessed troponins post-exercise, but the results have varied and there have been disagreements about the mechanism of troponin release. The aim of this paper was to review the literature, and to consider factors and mechanisms regarding exercise-induced increase of troponin. 145 studies were found after a search in pubmed and inclusion of additional articles found in the reference list of the first articles. Results showed that troponin rises in 0-100% of subjects after prolonged heavy exercise like marathon, but also after short-term and intermittent exercise like 30min of running and basketball. The variation can be due to factors like intensity, age, training experience, variation in sample size, blood sample timing and troponin assay. The pattern of troponin level post-exercise corresponds to release from the cytosolic compartment of cardiomyocytes. Increased membrane permeability might be caused by production of reactive oxygen species or alterations in calcium, pH, glucose/fat metabolism or in communication between integrins. Other suggested mechanisms are increased cardiovascular stress, inflammation, vasculitis, release of troponin degradation products in "blebs", dehydration, impaired renal clearance and expression of cardiac troponin in skeletal muscle. It can be concluded that both heavy and light exercise may cause elevated troponin, which have to be considered when patient are suspected to have a myocardial infarction. Several factors probably influence post-exercise levels of troponin, but the mechanism of release is most likely physiologic. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Analytical and assay issues for use of cardiac troponin testing for risk stratification in primary care.

    PubMed

    Wu, Alan H B; Christenson, Robert H

    2013-08-01

    Cardiac troponin is the standard marker for diagnosis of acute myocardial infarction and risk stratification of patients who present to an emergency department with signs and symptoms of acute cardiac ischemia. Over the past few years, the analytical sensitivity of assays for cardiac troponin has improved significantly to the point where a detectable amount of troponin can be measured in essentially all healthy subjects. Recent studies have shown that use of a highly sensitive troponin assays may provide value to traditional markers of primary disease risk for patients, i.e., for those who have no history of heart disease. There are barriers to the adoption of cardiac troponin for screening high risk cohorts such as the elderly, diabetics and perhaps even the asymptomatic population. Strategies used for the assignment of cutoff concentrations in acute care, i.e., the 99 th percentile, may not be appropriate for primary care as changes over baseline levels may provide more accurate information of risk than cross-sectional results. A review of biological variation has shown that cardiac troponin as a biomarker has low index of individuality, indicating that reference values are of little utility. Whether or not cardiac troponin can be released in reversible injury is a debate that could have significance for detecting minor myocardial injury. A major hurdle for use of troponin in primary care is the lack of assay standardization and nomenclature for the different generations of troponin assays. Standardization requires knowledge of what is released after cardiac injury and what the various cardiac troponin assays are measuring. Currently it is not clear if the cardiac troponin release after ischemic injury is identical to that in circulation of healthy individuals. This may affect the design of future assays and standardization approaches. There is potential that a marker of myocardial injury such as troponin can add to the value of existing indicators and biomarkers of cardiovascular disease risk. Additional analytical and clinical validations are needed to fully elucidate cardiac troponin metabolism and resolve ongoing clinical and laboratory issues. While these issues are directed to the use of troponin in primary care, most of these concepts are relevant to the use of troponin in acute coronary syndromes as well. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Troponin-T as a biomarker in neonates with perinatal asphyxia.

    PubMed

    Abiramalatha, T; Kumar, M; Chandran, S; Sudhakar, Y; Thenmozhi, M; Thomas, N

    2017-01-01

    Troponin-T is a commonly used cardiac biomarker, which could be useful in perinatal asphyxia. We aimed to analyze troponin-T concentrations in asphyxiated neonates and to correlate the concentrations with clinical outcomes. Data were collected from electronic medical records of neonates diagnosed with perinatal asphyxia over a period of four years. There were 63 neonates with moderate to severe encephalopathy, in whom serial troponin-T concentrations had been done on days 1, 3, and 7. 53 (84%) asphyxiated infants had troponin-T concentration >100 pg/ml at 2-4 h of life.The difference in troponin-T concentrations between moderate and severe encephalopathy was not statistically significant (173 vs. 263 pg/ml, p value 0.40). The difference in the concentrations at 72 hours between cooled and non-cooled neonates was not significant (48.5 vs. 62.5 pg/ml, p value 0.22). Troponin-T concentration was significantly higher in babies with hypotensive shock and hepatic injury, but not acute kidney injury. There was no significant correlation between troponin-T and the extent of resuscitation needed.Troponin-T concentration on day 1 of life was significantly higher in babies who died than who survived (407 vs. 168 pg/ml, p value 0.03). ROC curve for troponin-T to predict mortality had an area under the curve (AUC) of 0.803; the best cut-off value (190 pg/ml) had 82% sensitivity and 80% specificity. There was no significant difference in troponin-T concentrations between cooled and non-cooled neonates. Troponin-T concentration had a good predictive accuracy for mortality before discharge.

  13. High-sensitivity cardiac troponin I and risk of heart failure in patients with suspected acute coronary syndrome: a cohort study.

    PubMed

    Stelzle, Dominik; Shah, Anoop S V; Anand, Atul; Strachan, Fiona E; Chapman, Andrew R; Denvir, Martin A; Mills, Nicholas L; McAllister, David A

    2018-01-01

    Heart failure may occur following acute myocardial infarction, but with the use of high-sensitivity cardiac troponin assays we increasingly diagnose patients with minor myocardial injury. Whether troponin concentrations remain a useful predictor of heart failure in patients with acute coronary syndrome is uncertain. We identified all consecutive patients (n = 4748) with suspected acute coronary syndrome (61 ± 16 years, 57% male) presenting to three secondary and tertiary care hospitals. Cox-regression models were used to evaluate the association between high-sensitivity cardiac troponin I concentration and subsequent heart failure hospitalization. C-statistics were estimated to evaluate the predictive value of troponin for heart failure hospitalization. Over 2071 years of follow-up there were 83 heart failure hospitalizations. Patients with troponin concentrations above the upper reference limit (URL) were more likely to be hospitalized with heart failure than patients below the URL (118/1000 vs. 17/1000 person years, adjusted hazard ratio: 7.0). Among patients with troponin concentrations

  14. Interaction of cardiac troponin with cardiotonic drugs: a structural perspective.

    PubMed

    Li, Monica X; Robertson, Ian M; Sykes, Brian D

    2008-04-25

    Over the 40 years since its discovery, many studies have focused on understanding the role of troponin as a myofilament based molecular switch in regulating the Ca(2+)-dependent activation of striated muscle contraction. Recently, studies have explored the role of cardiac troponin as a target for cardiotonic agents. These drugs are clinically useful for treating heart failure, a condition in which the heart is no longer able to pump enough blood to other organs. These agents act via a mechanism that modulates the Ca(2+)-sensitivity of troponin; such a mode of action is therapeutically desirable because intracellular Ca(2+) concentration is not perturbed, preserving the regulation of other Ca(2+)-based signaling pathways. This review describes molecular details of the interaction of cardiac troponin with a variety of cardiotonic drugs. We present recent structural work that has identified the docking sites of several cardiotonic drugs in the troponin C-troponin I interface and discuss their relevance in the design of troponin based drugs for the treatment of heart disease.

  15. Effectiveness of 2-hour Troponin in High-risk Patients With Suspected Acute Coronary Syndrome.

    PubMed

    Bove, Joseph; Hochman, Steven; Miller, Jacob; Artim, Stephen

    2017-06-01

    Research has shown the safety and effectiveness of drawing a standard troponin level at presentation and again at 2 hours in only low-risk patients. Because high-sensitivity troponins are not currently approved in the United States, we studied the utility of a standard troponin that is presently in use. Our goal was to determine if 2-hour standard troponin would be safe and effective in the evaluation of a high-risk cohort of patients never studied previously. We conducted a single-center prospective observational study of adult patients presenting to the emergency department with signs and symptoms suggestive of acute coronary syndrome. Patients were defined as high risk if the attending physician planned to admit or transfer the patient to the observation unit. History, Electrocardiography, Age, Risk factors, Troponin scores were calculated on all patients to provide verification that the individuals were high risk. The primary outcome was a composite of 30-day myocardial infarction, death, cardiac arrest with return of spontaneous circulation, or dysrhythmia. The secondary outcome was 30-day revascularization. We included a total of 122 patients with an average follow-up of 112 days (minimum 30 days). A total of 86% of cases had History, Electrocardiography, Age, Risk factors, Troponin scores ≥4. The primary outcome was met in 22 (18%) patients, and the secondary outcome occurred in 7 (5.7%) patients. The negative predictive value of negative 2-hour troponins along with no significant delta troponin rise was 98.7%. Discharging patients thought to be high risk who have negative troponins at 0 and 2 hours and no delta troponin rise appears safe. No deaths occurred in follow-up. Larger studies are warranted.

  16. Prevalence of troponin elevations in patients with cardiac arrest and implications for assessing quality of care in hypothermia centers.

    PubMed

    Kontos, Michael C; Ornato, Joseph P; Kurz, Michael C; Roberts, Charlotte S; Gossip, Michelle; Dhindsa, Harinder S; Reid, Renee D; Peberdy, Mary A

    2013-10-01

    The prevalence of troponin elevations in patients with cardiac arrest (CA) using newer generation troponin assays when the ninety-ninth percentile is used has not been well described. We studied patients admitted with CA without ST elevation myocardial infarction (MI). Treatment included a multidisciplinary protocol that included routine use of hypothermia for appropriate patients. Serial assessment of cardiac biomarkers, including troponin I was obtained over the initial 24 to 36 hours. Patients were classified into 1 of 5 groups on the basis of multiples of the ninety-ninth percentile (upper reference limit [URL]), using the peak troponin I value: <1×, 1 to 3×, 3 to 5×, 5 to 10×, and >10×. Serial changes between the initial and second troponin I values were also assessed. A total of 165 patients with CA (mean age 58 ± 16, 67% men) were included. Troponin I was detectable in all but 2 patients (99%); all others had peak troponin I values that were greater than or equal to the URL. Most patients had peak troponin I values >10× URL, including patients with ventricular fibrillation or ventricular tachycardia (85%), asystole (50%), and pulseless electrical activity (59%). Serial changes in troponin I were present in almost all patients: ≥20% change in 162 (98%), ≥30% change in 159 (96%), and an absolute increase of ≥0.02 ng/ml in 85% of patients. In conclusion, almost all patients with CA who survived to admission had detectable troponin I, most of whom met biomarker guideline criteria for MI. Given the high mortality of these patients, these data have important implications for MI mortality reporting at CA treatment centers. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. The Usefulness and Limitations of Point-of-care Cardiac Troponin Measurement in the Emergency Department.

    PubMed

    Suzuki, Kenichiro; Komukai, Kimiaki; Nakata, Kotaro; Kan, Renshi; Oi, Yuhei; Muto, Eri; Kashiwagi, Yusuke; Tominaga, Mitsutoshi; Miyanaga, Satoru; Ishikawa, Tetsuya; Okuno, Kenji; Uzura, Masahiko; Yoshimura, Michihiro

    2018-02-09

    Objective This study was carried out to examine the usefulness of point-of-care (POC) cardiac troponin in diagnosing acute coronary syndrome (ACS) and to understand the limitations of a POC cardiac troponin I/T-based diagnoses. Methods Patients whose cardiac troponin levels were measured in the emergency department using a POC system (AQT System; Radiometer, Tokyo, Japan) between January and December 2016 were retrospectively examined (N=1449). Patients who were < 20 years of age or who were admitted with cardiopulmonary arrest were excluded. The sensitivity and specificity of the POC cardiac troponin levels for the diagnosis of ACS were determined. Result One hundred and twenty of 1449 total patients had ACS (acute myocardial infarction, n=88; unstable angina n=32). On comparing the receiver operating characteristic (ROC) curves, the area under the curve (AUC) values for POC cardiac troponin I and cardiac troponin T were 0.833 and 0.786, respectively. The sensitivity and specificity of POC cardiac troponin I when using the 99th percentile (0.023 ng/mL) as the diagnostic cut-off value were 69.0% and 88.1%, respectively. The sensitivity of POC cardiac troponin I (99th percentile) was higher in the patients sampled > 3 h after symptom onset (83.3%) than in those sampled ≤ 3 h after symptom onset (58.8%, p < 0.01). Conclusion When sampled > 3 h after the onset of symptoms, the POC cardiac troponin I level is considered to be suitable for use in diagnosing ACS. However, when sampled ≤ 3 h after the onset of symptoms, careful interpretation of POC cardiac troponins is therefore required to rule out ACS.

  18. Nasal vaccination with troponin reduces troponin specific T-cell responses and improves heart function in myocardial ischemia–reperfusion injury

    PubMed Central

    Frenkel, Dan; Pachori, Alok S.; Zhang, Lunan; Dembinsky-Vaknin, Adi; Farfara, Dorit; Petrovic-Stojkovic, Sanja; Dzau, Victor J.

    2009-01-01

    Myocardial ischemia with subsequent reperfusion (MI/R) can lead to significant myocardial damage. Ischemia initiates inflammation at the blood–microvascular endothelial cell interface and contributes significantly to both acute injury and repair of the damaged tissue. We have found that MI/R injury in mice is associated with a cellular immune response to troponin. Myocardial cells exclusively synthesize troponin and release the troponin into the bloodstream following injury. Mucosally administered proteins induce T cells that secrete anti-inflammatory cytokines such as IL-10 and transforming growth factor β at the anatomical site where the protein localizes. We found that nasal administration of the three subunits of troponin (C, I and T isoforms), given prior to or 1 h following MI/R, decreased infarct size by 40% measured 24 h later. At 1.5 months following MI/R, there was a 50% reduction in infarct size and improvement in cardiac function as measured by echocardiography. Protection was associated with a reduction of cellular immunity to troponin. Immunohistochemistry demonstrated increased IL-10 and reduced IFN-γ in the area surrounding the ischemic infarct following nasal troponin. Adoptive transfer of CD4+ T cells to mice from nasally troponin-treated mice 1 h after the MI/R decreased infarct size by 72%, whereas CD4+ T cells from IL-10−/− mice or nasally BSA-treated mice had no effect. Our results demonstrate that IL-10-secreting CD4+ T cells induced by nasal troponin reduce injury following MI/R. Modulation of cardiac inflammation by nasal troponin provides a novel treatment to decrease myocardial damage and enhance recovery after myocardial ischemia. PMID:19515797

  19. Acute coronary syndrome vs nonspecific troponin elevation: clinical predictors and survival analysis.

    PubMed

    Alcalai, Ronny; Planer, David; Culhaoglu, Afsin; Osman, Aydin; Pollak, Arthur; Lotan, Chaim

    2007-02-12

    Although troponin is considered a specific marker for the diagnosis of acute coronary syndrome (ACS), recent studies have shown troponin elevation in a variety of nonischemic conditions. Our aim was to determine the predictors for the diagnosis of ACS in the presence of an abnormal troponin level. All patients with abnormal troponin T levels were analyzed. Demographic and clinical data were collected and death was recorded. The study group was divided into 2 subgroups: ACS vs nonthrombotic troponin elevation. A multivariate logistic regression analysis was performed to define variables that predict the diagnosis of ACS. The positive predictive value (PPV) for ACS diagnosis was calculated, and a survival analysis was performed. During the study period, 615 patients had elevated troponin T levels. Only 326 patients (53%) received a main diagnosis of ACS, while 254 (41%) had nonthrombotic troponin elevation; for 35 patients (6%), the diagnosis was not conclusive. Positive predictors for the diagnosis of ACS were age between 40 and 70 years, history of hypertension or ischemic heart disease, normal renal function, and a troponin T level higher than 1.0 ng/mL. The overall PPV of troponin T for ACS diagnosis was only 56% (95% CI, 52%-60%). The PPV of troponin T level higher than 1.0 ng/mL in the presence of normal renal function was 90% but was as low as 27% for values of 0.1 to 1.0 ng/mL for elderly patients with renal failure. In-hospital and long-term survival rates were significantly better (P<.001) for patients with ACS. Nonspecific troponin elevation is a common finding among hospitalized patients and correlates with worse prognosis. The diagnosis of myocardial infarction should still mostly be based on the clinical presentation. The predictors and algorithm suggested in this study might increase the diagnostic accuracy of ACS and direct the appropriate treatment.

  20. Disparate Fluorescence Properties of 2-[4′-(Iodoacetamido)anilino]-Naphthalene-6-Sulfonic Acid Attached to Cys-84 and Cys-35 of Troponin C in Cardiac Muscle Troponin

    PubMed Central

    Dong, Wen-Ji; Wang, Chien-Kao; Gordon, Albert M.; Cheung, Herbert C.

    1997-01-01

    Two monocysteine mutants of cardiac muscle troponin C, cTnC(C35S) and cTnC(C84S), were genetically generated and labeled with the fluorescent probe 2-[4′-(iodoacetamido)anilino]naphthalene-6-sulfonic acid (IAANS) at Cys-84 and Cys-35, respectively. Cys-84 is located on helix D in the regulatory N-domain, and Cys-35 is at the -y position of the inactive 12-residue loop of site I. These labeled mutants were studied by a variety of steady-state and time-resolved fluorescence methods. In the absence of divalent cation, the fluorescence of the attached IAANS indicated an exposed environment at Cys-35 and a relatively less-exposed environment at Cys-84. The binding of Ca2+ to the single regulatory site elicited a large enhancement of the emission of IAANS attached to Cys-84, but only marginal fluorescence changes of the probe at Cys-35. Upon reconstitution of the labeled cTnC mutants with troponin I and troponin T to form the three-subunit troponin, the fluorescence of IAANS-Cys-84 in apo-troponin was spectrally similar to that observed with the Ca2+-loaded uncomplexed cTnC mutant. Only very moderate changes in the fluorescence of IAANS-Cys-84 were observed when the regulatory site in reconstituted troponin was saturated. The exposed Cys-35 environment of the uncomplexed cTnC mutant became considerably less exposed and less polar when the mutant was incorporated into apo-troponin. In contrast to the Cys-84 site, saturation of the regulatory site II by Ca2+ in reconstituted troponin resulted in a reversal of the environment of the Cys-35 site toward a more exposed and more polar environment. These results indicated involvement of the inactive loop I in the Ca2+ trigger mechanism in cardiac muscle. The fluorescence of IAANS at both Cys-84 and Cys-35 was sensitive to phosphorylation of cTnI in reconstituted troponin, and the sensitivity was observed with both apo-troponin and Ca2+-loaded troponin. PMID:9017210

  1. Troponin and Cardiac Events in Stable Ischemic Heart Disease and Diabetes.

    PubMed

    Everett, Brendan M; Brooks, Maria Mori; Vlachos, Helen E A; Chaitman, Bernard R; Frye, Robert L; Bhatt, Deepak L

    2015-08-13

    Cardiac troponin concentrations are used to identify patients who would benefit from urgent revascularization for acute coronary syndromes. We hypothesized that they might be used in patients with stable ischemic heart disease to identify those at high risk for cardiovascular events who might also benefit from prompt coronary revascularization. We measured the cardiac troponin T concentration at baseline with a high-sensitivity assay in 2285 patients who had both type 2 diabetes and stable ischemic heart disease and were enrolled in the Bypass Angioplasty Revascularization Investigation in Type 2 Diabetes trial. We tested for an association between the troponin T concentration and a composite end point of death from cardiovascular causes, myocardial infarction, or stroke; we then evaluated whether random assignment to prompt revascularization reduced the rate of the composite end point in patients with an abnormal troponin T concentration (≥14 ng per liter) as compared with those with a normal troponin T concentration (<14 ng per liter). Of the 2285 patients, 2277 (99.6%) had detectable (≥3 ng per liter) troponin T concentrations and 897 (39.3%) had abnormal troponin T concentrations at baseline. The 5-year rate of the composite end point was 27.1% among the patients who had had abnormal troponin T concentrations at baseline, as compared with 12.9% among those who had had normal baseline troponin T concentrations. In models that were adjusted for cardiovascular risk factors, severity of diabetes, electrocardiographic abnormalities, and coronary anatomy, the hazard ratio for the composite end point among patients with abnormal troponin T concentrations was 1.85 (95% confidence interval [CI], 1.48 to 2.32; P<0.001). Among patients with abnormal troponin T concentrations, random assignment to prompt revascularization, as compared with medical therapy alone, did not result in a significant reduction in the rate of the composite end point (hazard ratio, 0.96; 95% CI, 0.74 to 1.25). The cardiac troponin T concentration was an independent predictor of death from cardiovascular causes, myocardial infarction, or stroke in patients who had both type 2 diabetes and stable ischemic heart disease. An abnormal troponin T value of 14 ng per liter or higher did not identify a subgroup of patients who benefited from random assignment to prompt coronary revascularization. (Funded by the National Institutes of Health and Roche Diagnostics; BARI 2D ClinicalTrials.gov number, NCT00006305.).

  2. A pilot study of cardiac troponin I in patients with acute myocardial infarction and unstable angina.

    PubMed

    Selim, Najlaa A; Hmouda, Houssem T

    2002-05-01

    To assess the value of cardiac troponin I in the initial management of acute myocardial infarction and unstable angina, as well as the concordance between creatine phosphokinase-cardiac isoenzyme and cardiac troponin I. We reviewed retrospectively the charts of 32 patients with acute myocardial infarction or unstable angina admitted to the Intensive Care Unit from the Emergency Room of King Khalid Military City Hospital, Hafar-Al-Batin, Kingdom of Saudi Arabia from April 1998 to September 2000. The time of admission to the intensive care unit, which corresponds to the beginning of thrombolytic therapy, the time when cardiac enzymes (creatine phosphokinase-cardiac isoenzyme and cardiac troponin I) are available as well as number of cardiac troponin I determinations before obtaining a significant positive result (>2ng/ml) and the delay between admission and the first significant positive result of cardiac troponin I, were evaluated. Sixteen patients had confirmed acute myocardial infarction based on the association of typical chest pain, electrocardiographic findings with ST segment elevation and significant increase of the ratio creatine phosphokinase-cardiac isoenzyme/creatine phosphokinase > 10%. Sixteen patients had unstable angina and out of the 16 patients (81.25%) with acute myocardial infarction, 13 received thrombolytic therapy which was initiated on the basis of typical clinical history and electrocardiographic features, before the availability of cardiac enzymes. Troponin I was available in only 13 cases. The number of tests performed in these patients was 32. The first positive result of cardiac troponin I was available within a mean time of 16.66 20.8 hours from admission. The number of negative tests performed before obtaining a frank positive result was 9 in 12 patients. The number of positive tests after having obtained the first frank positive cardiac troponin I result was 10 in 12 patients. In all cases of cardiac troponin I, results were concordant with creatine phosphokinase-cardiac isoenzyme. In the 16 patients with unstable angina, only 11 patients had cardiac troponin I serum level. A total of 21 tests were performed. In 9 patients 14 cardiac troponin I tests were < 2 ng/ml. This was correlated with normal creatine phosphokinase-cardiac isoenzyme/creatine phosphokinase ratio. In 2 patients, 7 cardiac troponin I tests were positive. Both of them had significant increase of creatine phosphokinase-cardiac isoenzyme/creatine phosphokinase ratio and electrocardiographic features of myocardial ischemia and were referred for urgent coronary angiography. Cardiac troponin I levels are not helpful in the initial management of patients with acute myocardial infarction. Thrombolytic therapy should be therefore instituted before the availability of cardiac troponin I results. However, cardiac troponin I results are concordant with creatine phosphokinase-cardiac isoenzyme in retrospective confirmation of the diagnosis of acute myocardial infarction a few hours after onset. In patients with unstable angina, cardiac troponin I should be used mainly for risk stratification.

  3. Binding mode of cytochalasin B to F-actin is altered by lateral binding of regulatory proteins.

    PubMed

    Suzuki, N; Mihashi, K

    1991-01-01

    The binding of cytochalasin B (CB) to F-actin was studied using a trace amount of [3H]-cytochalasin B. F-Actin-bound CB was separated from free CB by ultracentrifugation and the amount of F-actin-bound CB was determined by comparing the radioactivity both in the supernatant and in the precipitate. A filament of pure F-actin possessed one high-affinity binding site for CB (Kd = 5.0 nM) at the B-end. When the filament was bound to native tropomyosin (complex of tropomyosin and troponin), two low-affinity binding sites for CB (Kd = 230 nM) were created, while the high-affinity binding site was reserved (Kd = 3.4 nM). It was concluded that the creation of low-affinity binding sites was primarily due to binding of tropomyosin to F-actin, as judged from the following two observations: (1) a filament of F-actin/tropomyosin complex possessed one high-affinity binding site (Kd = 3.9 nM) plus two low-affinity binding sites (Kd = 550 nM); (2) the Ca2(+)-receptive state of troponin C in F-actin/native tropomyosin complex did not affect CB binding.

  4. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    PubMed

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  5. Cardiac troponin I in sickle cell crisis.

    PubMed

    Aslam, Ahmad K; Rodriguez, Carlos; Aslam, Ahmed F; Vasavada, Balendu C; Khan, Ijaz A

    2009-03-20

    Gross and microscopic findings consistent with acute and healed myocardial injury without coronary artery disease have been described in autopsy studies of patients with sickle cell crisis. The present study was designed to determine whether serum levels of cardiac troponin I are elevated in sickle cell crisis. Cardiac troponin I levels were measured in 32 patients age>18 years with the admission diagnosis of sickle cell crisis. All patients had cardiac troponin I level drawn >24 h after the onset of symptoms. The clinical profile and electrocardiograms were analyzed. Out of 32 patients, 2 patients had serum cardiac troponin I elevated, both had presented with acute chest syndrome. Serum cardiac troponin I may be elevated during sickle cell crisis, possibly by myocardial ischemia resulting from microvascular coronary obstruction during sickle cell crisis.

  6. Evaluation of first-draw whole blood, point-of-care cardiac markers in the context of the universal definition of myocardial infarction: a comparison of a multimarker panel to troponin alone and to testing in the central laboratory.

    PubMed

    Lee-Lewandrowski, Elizabeth; Januzzi, James L; Grisson, Ricky; Mohammed, Asim A; Lewandrowski, Grant; Lewandrowski, Kent

    2011-04-01

    Previous studies evaluating point-of-care testing (POCT) for cardiac biomarkers did not use current recommendations for troponin cutoff values or recognize the recent universal definition of acute myocardial infarction. Traditionally, achieving optimal sensitivity for the detection of myocardial injury on initial presentation required combining cardiac troponin and/or creatine kinase isoenzyme MB with an early marker, usually myoglobin. In recent years, the performance of central laboratory combining cardiac troponin assays has improved significantly, potentially obviating the need for a multimarker panel to achieve optimum sensitivity. To compare 2 commonly used POCT strategies to a fourth generation, central laboratory cardiac troponin T assay on first-draw specimens from patients being evaluated for acute myocardial infarction in the emergency department. The 2 strategies included a traditional POCT multimarker panel and a newer POCT method using cardiac troponin I alone. Blood specimens from 204 patients presenting to the emergency department with signs and/or symptoms of myocardial ischemia were measured on the 2 POCT systems and by a central laboratory method. The diagnosis for each patient was determined by retrospective chart review. The cardiac troponin T assasy alone was more sensitive for acute myocardial infarction than the multimarker POCT panel with equal or better specificity. When compared with a POCT troponin I, the cardiac troponin T was also more sensitive, but this difference was not significant. The POCT troponin I alone also had the same sensitivity as the multimarker panel. Testing for combining cardiac troponin alone using newer, commercially available, central laboratory or POCT assays performed with equal or greater sensitivity to acute myocardial infarction as the older, traditional, multimarker panel. In the near future, high-sensitivity, central laboratory troponins will be available for routine clinical use. As a result, the quality gap between central laboratories and older POCT methods will continue to widen, unless the performance of the POCT methods is improved.

  7. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy: A Prospective, Observational Cohort Study.

    PubMed

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B; Zorumski, Charles F; Conway, Charles; Nagele, Peter

    2017-04-01

    While electroconvulsive therapy is widely regarded as a lifesaving and safe procedure, evidence regarding its effects on myocardial cell injury is sparse. The objective of this investigation was to determine the incidence and magnitude of new cardiac troponin elevation after electroconvulsive therapy using a novel high-sensitivity cardiac troponin I assay. This was a prospective cohort study in adult patients undergoing electroconvulsive therapy in a single academic center (up to three electroconvulsive therapy treatments per patient). The primary outcome was new high-sensitivity cardiac troponin I elevation after electroconvulsive therapy, defined as an increase of high-sensitivity cardiac troponin I greater than 100% after electroconvulsive therapy compared to baseline with at least one value above the limit of quantification (10 ng/l). Twelve-lead electrocardiogram and high-sensitivity cardiac troponin I values were obtained before and 15 to 30 min after electroconvulsive therapy; in a subset of patients, an additional 2-h high-sensitivity cardiac troponin I value was obtained. The final study population was 100 patients and a total of 245 electroconvulsive therapy treatment sessions. Eight patients (8 of 100; 8%) experienced new high-sensitivity cardiac troponin I elevation after electroconvulsive therapy with a cumulative incidence of 3.7% (9 of 245 treatments; one patient had two high-sensitivity cardiac troponin I elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2 of 245; 0.8%). Median high-sensitivity cardiac troponin I concentrations did not increase significantly after electroconvulsive therapy. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of electroconvulsive therapy treatments. Electroconvulsive therapy appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with preexisting cardiovascular risk factors, however, may develop new cardiac troponin elevation after electroconvulsive therapy, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia.

  8. Cardiac ischemia in patients with septic shock randomized to vasopressin or norepinephrine

    PubMed Central

    2013-01-01

    Introduction Cardiac troponins are sensitive and specific biomarkers of myocardial necrosis. We evaluated troponin, CK, and ECG abnormalities in patients with septic shock and compared the effect of vasopressin (VP) versus norepinephrine (NE) on troponin, CK, and ECGs. Methods This was a prospective substudy of a randomized trial. Adults with septic shock randomly received, blinded, a low-dose infusion of VP (0.01 to 0.03 U/min) or NE (5 to 15 μg/min) in addition to open-label vasopressors, titrated to maintain a mean blood pressure of 65 to 75 mm Hg. Troponin I/T, CK, and CK-MB were measured, and 12-lead ECGs were recorded before study drug, and 6 hours, 2 days, and 4 days after study-drug initiation. Two physician readers, blinded to patient data and drug, independently interpreted ECGs. Results We enrolled 121 patients (median age, 63.9 years (interquartile range (IQR), 51.1 to 75.3), mean APACHE II 28.6 (SD 7.7)): 65 in the VP group and 56 in the NE group. At the four time points, 26%, 36%, 32%, and 21% of patients had troponin elevations, respectively. Baseline characteristics and outcomes were similar between patients with positive versus negative troponin levels. Troponin and CK levels and rates of ischemic ECG changes were similar in the VP and the NE groups. In multivariable analysis, only APACHE II was associated with 28-day mortality (OR, 1.07; 95% CI, 1.01 to 1.14; P = 0.033). Conclusions Troponin elevation is common in adults with septic shock. We observed no significant differences in troponin, CK, and ECGs in patients treated with vasopressin and norepinephrine. Troponin elevation was not an independent predictor of mortality. Trial registration Controlled-trials.com ISRCTN94845869 PMID:23786655

  9. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    PubMed Central

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept. PMID:28856047

  10. Increase in Cardiac Troponin I in a Lamb with Tetralogy of Fallot

    PubMed Central

    NEUWALD, Elisa Barp; SOARES, Frederico Aécio Carvalho; DREYER, Cristina Terres; CARNESELLA, Samuel; WOUTERS, Angelica Terezinha Barth; GONZÁLEZ, Félix Hilario Diaz; DRIEMEIER, David

    2013-01-01

    ABSTRACT This study describes a case of tetralogy of Fallot in a lamb showing failure to thrive and signs of respiratory distress. Physical examination, electrocardiography, thoracic radiographies, echocardiography and cardiac troponin I evaluation were performed. The value of cardiac troponin I was compared with the values of 10 healthy lambs of the same age and breed, and the affected animal demonstrated an increase in cardiac troponin I. Due to the poor prognosis, euthanasia was indicated, and necropsy confirmed the diagnosis. This is the first report of an increase in cardiac troponin I in a lamb with tetralogy of Fallot. PMID:23685750

  11. Impact of genotype and phenotype on cardiac biomarkers in patients with transthyretin amyloidosis – Report from the Transthyretin Amyloidosis Outcome Survey (THAOS)

    PubMed Central

    Kristen, Arnt V.; Maurer, Mathew S.; Rapezzi, Claudio; Mundayat, Rajiv; Suhr, Ole B.; Damy, Thibaud

    2017-01-01

    Aim Cardiac troponins and natriuretic peptides are established for risk stratification in light-chain amyloidosis. Data on cardiac biomarkers in transthyretin amyloidosis (ATTR) are lacking. Methods and results Patients (n = 1617) with any of the following cardiac biomarkers, BNP (n = 1079), NT-proBNP (n = 550), troponin T (n = 274), and troponin I (n = 108), available at baseline in the Transthyretin Amyloidosis Outcomes Survey (THAOS) were analyzed for differences between genotypes and phenotypes and their association with survival. Median level of BNP was 68.0 pg/mL (IQR 30.5–194.9), NT-proBNP 337.9 pg/mL (IQR 73.0–2584.0), troponin T 0.03 μg/L (IQR 0.01–0.05), and troponin I 0.08 μg/L (IQR 0.04–0.13). NT-proBNP and BNP were higher in wild-type than mutant-type ATTR, troponin T and I did not differ, respectively. Non-Val30Met patients had higher BNP, NT-proBNP and troponin T levels than Val30Met patients, but not troponin I. Late-onset Val30Met was associated with higher levels of troponin I and troponin T compared with early-onset. 115 patients died during a median follow-up of 1.2 years. Mortality increased with increasing quartiles (BNP/NT-proBNP Q1 = 1.7%, Q2 = 5.2%, Q3 = 21.7%, Q4 = 71.3%; troponin T/I Q1 = 6.5%, Q2 = 14.5%, Q3 = 33.9%, Q4 = 45.2%). Three-year overall-survival estimates for BNP/NT-proBNP and troponin T/I quartiles differed significantly (p<0.001). Stepwise risk stratification was achieved by combining NT-proBNP/BNP and troponin T/I. From Cox proportional hazards model, age, modified body mass index, mutation (Val30Met vs. Non-Val30Met) and BNP/NT-proBNP (Q1–Q3 pooled vs. Q4) were identified as independent predictors of survival in patients with mutant-type ATTR. Conclusions In this ATTR patient cohort, cardiac biomarkers were abnormal in a substantial percentage of patients irrespective of genotype. Along with age, mBMI, and mutation (Val30Met vs. Non-Val30Met), cardiac biomarkers were associated with surrogates of disease severity with BNP/NT-proBNP identified as an independent predictor of survival in ATTR. Trial registration ClinicalTrials.gov NCT00628745 PMID:28384285

  12. The incremental value of troponin biomarkers in risk stratification of acute coronary syndromes: is the relationship multiplicative?

    PubMed

    Amin, Amit P; Nathan, Sandeep; Vassallo, Patricia; Calvin, James E

    2009-05-20

    To emphasize the importance of troponin in the context of a new score for risk stratifying acute coronary syndromes (ACS) patients. Although troponins have powerful prognostic value, current ACS scores do not fully capitalize this prognostic ability. Here, we weigh troponin status in a multiplicative manner to develop the TRACS score from previously published Rush score risk factors (RRF). 2,866 ACS patients (46.7% troponin positive) from 9 centers comprising the TRACS registry, were randomly split into derivation (n=1,422) and validation (n=1,444) cohorts. In the derivation sample, RRF sum was multiplied by 3 if troponins were positive to yield the TRACS score, which was grouped into five categories of 0-2, 3-5, 6-8, 9-11, 12-15 (multiples of 3). Predictive performance of this score to predict hospital death was ascertained in the validation sample. The TRACS score had ROC AUC of 0.71 in the validation cohort. Logistic regression, Kaplan-Meier analysis, likelihood-ratio and Bayesian Information Criterion (BIC) test indicated that weighing troponin status with 3 in the TRACS score improved the prediction of mortality. Hosmer-Lemeshow test indicated sound model fit. We demonstrate that weighing troponin as a multiple of 3 yields robust prognostication of hospital mortality in ACS patients, when used in the context of the TRACS score.

  13. The Incremental Value of Troponin Biomarkers in Risk Stratification of Acute Coronary Syndromes: Is the Relationship Multiplicative?

    PubMed Central

    Amin, Amit P; Nathan, Sandeep; Vassallo, Patricia; Calvin, James E

    2009-01-01

    Structured Abstract Objective: To emphasize the importance of troponin in the context of a new score for risk stratifying acute coronary syndromes (ACS) patients. Although troponins have powerful prognostic value, current ACS scores do not fully capitalize this prognostic ability. Here, we weigh troponin status in a multiplicative manner to develop the TRACS score from previously published Rush score risk factors (RRF). Methods: 2,866 ACS patients (46.7% troponin positive) from 9 centers comprising the TRACS registry, were randomly split into derivation (n=1,422) and validation (n=1,444) cohorts. In the derivation sample, RRF sum was multiplied by 3 if troponins were positive to yield the TRACS score, which was grouped into five categories of 0-2, 3-5, 6-8, 9-11, 12-15 (multiples of 3). Predictive performance of this score to predict hospital death was ascertained in the validation sample. Results: The TRACS score had ROC AUC of 0.71 in the validation cohort. Logistic regression, Kaplan-Meier analysis, likelihood-ratio and Bayesian Information Criterion (BIC) test indicated that weighing troponin status with 3 in the TRACS score improved the prediction of mortality. Hosmer-Lemeshow test indicated sound model fit. Conclusions: We demonstrate that weighing troponin as a multiple of 3 yields robust prognostication of hospital mortality in ACS patients, when used in the context of the TRACS score. PMID:19557150

  14. Critical review and meta-analysis on the combination of heart-type fatty acid binding protein (H-FABP) and troponin for early diagnosis of acute myocardial infarction.

    PubMed

    Lippi, Giuseppe; Mattiuzzi, Camilla; Cervellin, Gianfranco

    2013-01-01

    An early diagnosis is crucial for effective triage and management of patients with suspected acute myocardial infarction (AMI). Although troponin testing is the cornerstone of diagnosis, the sensitivity of this biomarker is still suboptimal at patient admission. The heart-type fatty acid binding protein (H-FABP) is an early and sensitive biomarker of myocardial ischemia, whose appropriate setting is in combination with troponin testing. We performed a systematic review and meta-analysis of articles that have assessed the combination of troponin and H-FABP in the early diagnosis of AMI. Eight studies, totaling 2735 patients, met the inclusion criteria but none of them used a high-sensitivity troponin immunoassay. The between-study variation was high (98.5%), and attributable to heterogeneity. When considered alone, troponin exhibited a significantly greater pooled area under the curve (AUC) than H-FABP alone (0.820 versus 0.784; p<0.001). The pooled specificity was also higher for troponin alone than for H-FABP alone (0.94 versus 0.83; p<0.001), whereas the cumulative sensitivity was lower for troponin than for H-FABP (0.73 versus 0.80; p=0.02). The combination of both biomarkers exhibited a greater AUC than troponin alone (0.881; p<0.001), as well as a higher pooled sensitivity (0.91; p<0.001), which was however counterbalanced by a lower specificity (0.82; p<0.001). These results attest that the combination of H-FABP with a conventional troponin immunoassay seems advantageous for increasing the sensitivity of the former biomarker, at the expense of a lower specificity. The introduction of H-FABP testing would hence require careful assessment of laboratory data or clinical signs and symptoms for excluding sources of elevation different from AMI. Further studies are needed to assess the diagnostic effectiveness of combining H-FABP with a high-sensitivity troponin immunoassay. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Implications of troponin testing in clinical medicine

    PubMed Central

    Goldmann, Britta U; Christenson, Robert H; Hamm, Christian W; Meinertz, Thomas; Ohman, E Magnus

    2001-01-01

    During the past decade considerable research has been conducted into the use of cardiac troponins, their diagnostic capability and their potential to allow risk stratification in patients with acute chest pain. Determination of risk in patients with suspected myocardial ischaemia is known to be as important as retrospective confirmation of a diagnosis of myocardial infarction (MI). Therefore, creatine kinase (CK)-MB - the former 'gold standard' in detecting myocardial necrosis - has been supplanted by new, more accurate biomarkers.Measurement of cardiac troponin levels constitute a substantial determinant in assessment of ischaemic heart disease, the presentations of which range from silent ischaemia to acute MI. Under these conditions, troponin release is regarded as surrogate marker of thrombus formation and peripheral embolization, and therefore new therapeutic strategies are focusing on potent antithrombotic regimens to improve long-term outcomes. Although elevated troponin levels are highly sensitive and specific indicators of myocardial damage, they are not always reflective of acute ischaemic coronary artery disease; other processes have been identified that cause elevations in these biomarkers. However, because prognosis appears to be related to the presence of troponins regardless of the mechanism of myocardial damage, clinicians increasingly rely on troponin assays when formulating individual therapeutic plans. PMID:11806777

  16. How genome complexity can explain the difficulty of aligning reads to genomes.

    PubMed

    Phan, Vinhthuy; Gao, Shanshan; Tran, Quang; Vo, Nam S

    2015-01-01

    Although it is frequently observed that aligning short reads to genomes becomes harder if they contain complex repeat patterns, there has not been much effort to quantify the relationship between complexity of genomes and difficulty of short-read alignment. Existing measures of sequence complexity seem unsuitable for the understanding and quantification of this relationship. We investigated several measures of complexity and found that length-sensitive measures of complexity had the highest correlation to accuracy of alignment. In particular, the rate of distinct substrings of length k, where k is similar to the read length, correlated very highly to alignment performance in terms of precision and recall. We showed how to compute this measure efficiently in linear time, making it useful in practice to estimate quickly the difficulty of alignment for new genomes without having to align reads to them first. We showed how the length-sensitive measures could provide additional information for choosing aligners that would align consistently accurately on new genomes. We formally established a connection between genome complexity and the accuracy of short-read aligners. The relationship between genome complexity and alignment accuracy provides additional useful information for selecting suitable aligners for new genomes. Further, this work suggests that the complexity of genomes sometimes should be thought of in terms of specific computational problems, such as the alignment of short reads to genomes.

  17. Evaluation of Changes in Morphology and Function of Human Induced Pluripotent Stem Cell Derived Cardiomyocytes (HiPSC-CMs) Cultured on an Aligned-Nanofiber Cardiac Patch

    PubMed Central

    Khan, Mahmood; Xu, Yanyi; Hua, Serena; Johnson, Jed; Belevych, Andriy; Janssen, Paul M. L.; Gyorke, Sandor; Guan, Jianjun; Angelos, Mark G.

    2015-01-01

    Introduction Dilated cardiomyopathy is a major cause of progressive heart failure. Utilization of stem cell therapy offers a potential means of regenerating viable cardiac tissue. However, a major obstacle to stem cell therapy is the delivery and survival of implanted stem cells in the ischemic heart. To address this issue, we have developed a biomimetic aligned nanofibrous cardiac patch and characterized the alignment and function of human inducible pluripotent stem cell derived cardiomyocytes (hiPSC-CMs) cultured on this cardiac patch. This hiPSC-CMs seeded patch was compared with hiPSC-CMs cultured on standard flat cell culture plates. Methods hiPSC-CMs were cultured on; 1) a highly aligned polylactide-co-glycolide (PLGA) nanofiber scaffold (~50 microns thick) and 2) on a standard flat culture plate. Scanning electron microscopy (SEM) was used to determine alignment of PLGA nanofibers and orientation of the cells on the respective surfaces. Analysis of gap junctions (Connexin-43) was performed by confocal imaging in both the groups. Calcium cycling and patch-clamp technique were performed to measure calcium transients and electrical coupling properties of cardiomyocytes. Results SEM demonstrated >90% alignment of the nanofibers in the patch which is similar to the extracellular matrix of decellularized rat myocardium. Confocal imaging of the cardiomyocytes demonstrated symmetrical alignment in the same direction on the aligned nanofiber patch in sharp contrast to the random appearance of cardiomyocytes cultured on a tissue culture plate. The hiPSC-CMs cultured on aligned nanofiber cardiac patches showed more efficient calcium cycling compared with cells cultured on standard flat surface culture plates. Quantification of mRNA with qRT-PCR confirmed that these cardiomyocytes expressed α-actinin, troponin-T and connexin-43 in-vitro. Conclusions Overall, our results demonstrated changes in morphology and function of human induced pluripotent derived cardiomyocytes cultured in an anisotropic environment created by an aligned nanofiber patch. In this environment, these cells better approximate normal cardiac tissue compared with cells cultured on flat surface and can serve as the basis for bioengineering of an implantable cardiac patch. PMID:25993466

  18. Evaluation of Changes in Morphology and Function of Human Induced Pluripotent Stem Cell Derived Cardiomyocytes (HiPSC-CMs) Cultured on an Aligned-Nanofiber Cardiac Patch.

    PubMed

    Khan, Mahmood; Xu, Yanyi; Hua, Serena; Johnson, Jed; Belevych, Andriy; Janssen, Paul M L; Gyorke, Sandor; Guan, Jianjun; Angelos, Mark G

    2015-01-01

    Dilated cardiomyopathy is a major cause of progressive heart failure. Utilization of stem cell therapy offers a potential means of regenerating viable cardiac tissue. However, a major obstacle to stem cell therapy is the delivery and survival of implanted stem cells in the ischemic heart. To address this issue, we have developed a biomimetic aligned nanofibrous cardiac patch and characterized the alignment and function of human inducible pluripotent stem cell derived cardiomyocytes (hiPSC-CMs) cultured on this cardiac patch. This hiPSC-CMs seeded patch was compared with hiPSC-CMs cultured on standard flat cell culture plates. hiPSC-CMs were cultured on; 1) a highly aligned polylactide-co-glycolide (PLGA) nanofiber scaffold (~50 microns thick) and 2) on a standard flat culture plate. Scanning electron microscopy (SEM) was used to determine alignment of PLGA nanofibers and orientation of the cells on the respective surfaces. Analysis of gap junctions (Connexin-43) was performed by confocal imaging in both the groups. Calcium cycling and patch-clamp technique were performed to measure calcium transients and electrical coupling properties of cardiomyocytes. SEM demonstrated >90% alignment of the nanofibers in the patch which is similar to the extracellular matrix of decellularized rat myocardium. Confocal imaging of the cardiomyocytes demonstrated symmetrical alignment in the same direction on the aligned nanofiber patch in sharp contrast to the random appearance of cardiomyocytes cultured on a tissue culture plate. The hiPSC-CMs cultured on aligned nanofiber cardiac patches showed more efficient calcium cycling compared with cells cultured on standard flat surface culture plates. Quantification of mRNA with qRT-PCR confirmed that these cardiomyocytes expressed α-actinin, troponin-T and connexin-43 in-vitro. Overall, our results demonstrated changes in morphology and function of human induced pluripotent derived cardiomyocytes cultured in an anisotropic environment created by an aligned nanofiber patch. In this environment, these cells better approximate normal cardiac tissue compared with cells cultured on flat surface and can serve as the basis for bioengineering of an implantable cardiac patch.

  19. Cardiac troponins--Translational biomarkers in cardiology: Theory and practice of cardiac troponin high-sensitivity assays.

    PubMed

    Adamcova, Michaela; Popelova-Lencova, Olga; Jirkovsky, Eduard; Simko, Fedor; Gersl, Vladimir; Sterba, Martin

    2016-01-01

    Tn is a unique translational biomarker in cardiology whose potential has not been diminished in the new era of high sensitive assays. cTns can be valuable markers in cardiac diseases as well as in infectious diseases and respiratory diseases. Furthermore, the role of cTns is growing in the routine evaluation of cardioxicity and in determining the efficacy/safety ratio of novel cardioprotective strategies in clinical settings. cTns can detect myocardial injury not only in a wide spectrum of laboratory animals in experimental studies in vivo, but also in isolated heart models or cardiomyocytes in vitro. The crucial issue regarding the cross-species usage of cardiac troponin investigation remains the choice of cardiac troponin testing. This review summarizes the recent proteomic data on aminoacid sequences of cTnT and cTnI in various species, as well as selected analytical characteristics of human cardiac troponin high-sensitivity assays. Due to the highly phylogenetically conserved structure of troponins, the same bioindicator can be investigated using the same method in both clinical and experimental cardiology, thus contributing to a better understanding of the pathogenesis of cardiac diseases as well as to increased effectiveness of troponin use in clinical practice. Measuring cardiac troponins using commercially available human high-sensitivity cardiac troponin tests with convenient antibodies selected on the basis of adequate proteomic knowledge can solve many issues which would otherwise be difficult to address in clinical settings for various ethical and practical reasons. Our survey could help elaborate the practical guidelines for optimizing the choice of cTns assay in cardiology. © 2016 International Union of Biochemistry and Molecular Biology.

  20. Association Between Troponin Levels and Embolic Stroke of Undetermined Source.

    PubMed

    Merkler, Alexander E; Gialdini, Gino; Murthy, Santosh B; Salehi Omran, Setareh; Moya, Antonio; Lerario, Michael P; Chong, Ji; Okin, Peter M; Weinsaft, Jonathan W; Safford, Monika M; Fink, Matthew E; Navi, Babak B; Iadecola, Costantino; Kamel, Hooman

    2017-09-22

    Our aim was to determine whether patients with embolic strokes of undetermined source (ESUS) have higher rates of elevated troponin than patients with noncardioembolic strokes. CAESAR (The Cornell Acute Stroke Academic Registry) prospectively enrolled all adults with acute stroke from 2011 to 2014. Two neurologists used standard definitions to retrospectively ascertain the etiology of stroke, with a third resolving disagreements. In this analysis we included patients with ESUS and, as controls, patients with small- and large-artery strokes; only patients with a troponin measured within 24 hours of stroke onset were included. A troponin elevation was defined as a value exceeding our laboratory's upper limit (0.04 ng/mL) without a clinically recognized acute ST-segment elevation myocardial infarction. Multiple logistic regression was used to evaluate the association between troponin elevation and ESUS after adjustment for demographics, stroke severity, insular infarction, and vascular risk factors. In a sensitivity analysis we excluded patients diagnosed with atrial fibrillation after discharge. Among 512 patients, 243 (47.5%) had ESUS, and 269 (52.5%) had small- or large-artery stroke. In multivariable analysis an elevated troponin was independently associated with ESUS (odds ratio 3.3; 95% confidence interval 1.2, 8.8). This result was unchanged after excluding patients diagnosed with atrial fibrillation after discharge (odds ratio 3.4; 95% confidence interval 1.3, 9.1), and the association remained significant when troponin was considered a continuous variable (odds ratio for log[troponin], 1.4; 95% confidence interval 1.1, 1.7). Elevations in cardiac troponin are more common in patients with ESUS than in those with noncardioembolic strokes. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  1. Mechanism of the calcium-regulation of muscle contraction--in pursuit of its structural basis.

    PubMed

    Wakabayashi, Takeyuki

    2015-01-01

    The author reviewed the research that led to establish the structural basis for the mechanism of the calcium-regulation of the contraction of striated muscles. The target of calcium ions is troponin on the thin filaments, of which the main component is the double-stranded helix of actin. A model of thin filament was generated by adding tropomyosin and troponin. During the process to provide the structural evidence for the model, the troponin arm was found to protrude from the calcium-depleted troponin and binds to the carboxyl-terminal region of actin. As a result, the carboxyl-terminal region of tropomyosin shifts and covers the myosin-binding sites of actin to block the binding of myosin. At higher calcium concentrations, the troponin arm changes its partner from actin to the main body of calcium-loaded troponin. Then, tropomyosin shifts back to the position near the grooves of actin double helix, and the myosin-binding sites of actin becomes available to myosin resulting in force generation through actin-myosin interactions.

  2. Cardiac troponin increases among marathon runners in the Perth Marathon: the Troponin in Marathons (TRIM) study.

    PubMed

    Hubble, Kelley M; Fatovich, Daniel M; Grasko, Jonathon M; Vasikaran, Samuel D

    2009-01-19

    To determine the prevalence of elevated troponin levels after a marathon, and test for an association with reduced renal clearance. Prospective observational study of entrants running the full (42 km) 2007 Perth Marathon, Western Australia. Elevated troponin levels (> or = 0.1 microg/L) after the race; pre- and post-race survey data, and biochemical parameters. 27% of runners (92/346) enrolled in the study, of whom 88 (96%) completed it. Most were men (71%; 65/92); mean age was 43.1 years (SD, 9.8 years; range, 25-64 years) and mean body mass index (BMI) was 24.1 kg/m(2). Raised troponin levels were seen in 32% of participants (28/88), the highest being 1.4 microg/L. The strongest predictor for developing elevated troponin levels was a decrease in weight (odds ratio [OR], 2.15; 95% CI, 1.27-3.65). Creatinine increase was also associated with elevated troponin levels (OR, 1.03; 95% CI, 1.01-1.06), but pre-race estimated glomerular filtration rate, age, sex, BMI, training factors, marathon experience and race time were not. Most runners (99%; 87/88) had elevated levels of ischaemia-modified albumin after the race. Troponin level increases were common among marathon finishers. The strongest predictors were weight loss and an increase in creatinine levels, suggesting that reduced renal clearance is an associated factor. Further study is needed to determine the clinical significance of these findings, and to understand the mechanism.

  3. The diagnostic value of troponin T testing in the community setting.

    PubMed

    Planer, David; Leibowitz, David; Paltiel, Ora; Boukhobza, Rina; Lotan, Chaim; Weiss, Teddy A

    2006-03-08

    Many patients presenting with chest pain to their family physician are referred to the emergency room, in part, due to lack of accurate objective diagnostic tools. This study aimed to assess the diagnostic value of bedside troponin T kit testing in patients presenting with chest pain to their family physician. Prospective, multi-center study. Consecutive subjects with chest pain were recruited from 44 community clinics in Jerusalem. Following clinical assessment by the family physician, qualitative troponin kit testing was performed. Patients with a negative clinical assessment and negative troponin kit were sent home and all others were referred to the emergency room. The final diagnosis at the time of hospital discharge was recorded and telephone follow up was performed after 60 days. Positive predictive value, negative predictive value, sensitivity and specificity of troponin kit for myocardial infarction diagnosis and of family physician for hospitalization, were assessed. Of 392 patients enrolled, 349 (89%) were included in the final analysis. The prevalence of myocardial infarction was 1.7%. The positive and negative predictive values of the troponin kit for myocardial infarction diagnosis were 100% and 99.7%, respectively. The positive and negative predictive values of the family physician's assessment to predict hospitalization were 41.4% and 94.1%, respectively. Troponin kit testing is an important tool to assist the family physician in the assessment of patients with chest pain in the community setting. Troponin kit testing may identify otherwise undiagnosed cases of myocardial infarctions, and reduce unnecessary referrals to the emergency room.

  4. Fragmented QRS complex is a prognostic marker of microvascular reperfusion and changes in LV function occur in patients with ST elevation myocardial infarction who underwent primary percutaneous coronary intervention.

    PubMed

    Zhang, Ruoxi; Chen, Shuyuan; Zhao, Qi; Sun, Meng; Yu, Bo; Hou, Jingbo

    2017-06-01

    The present study aimed to investigate the in-hospital and long-term prognostic value of fragmented QRS complex (fQRS) for microvascular reperfusion and changes in left ventricular (LV) function in patients with ST elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI). A total of 216 patients with STEMI undergoing primary PCI were included in the current study. Patients were divided into two groups based on the presence (n=126) or absence (n=90) of fQRS following electrocardiograms (ECGs) on admission. Following primary PCI and follow up, patients were divided into four groups based on new onset, resolution, persistence and absence of fQRS. Major adverse cardiac events were defined to include cardiovascular death, arrhythmia, heart failure, reinfarction and target vessel revascularization. The percentage of patients with heart failure and microvascular reperfusion differed significantly between the fQRS(+) and fQRS(-) groups. Levels of N-terminal pro-brain natriuretic peptide (NT-proBNP), Peak creatine kinase-MB (CK-MB) and Troponin I levels were observed to be significantly higher in the fQRS(+) group compared with the fQRS(-) group. In univariate logistic regression analysis, left ventricular ejection fraction (LVEF), NT-proBNP, Troponin I, Peak CK-MB and microvascular reperfusion were found to be associated with fQRS. Multivariate analysis identified that LVEF, NT-proBNP, Troponin I and microvascular reperfusion may be independent predictors of fQRS. The presence of fQRS was demonstrated to be associated with left ventricular dysfunction at follow up assessments. The presence of fQRS was not only significantly associated with myocardial microvascular reperfusion and left ventricular function, but was also a prognostic marker in STEMI.

  5. Cholesterol depletion by methyl-beta-cyclodextrin enhances myoblast fusion and induces the formation of myotubes with disorganized nuclei.

    PubMed

    Mermelstein, Cláudia S; Portilho, Débora M; Medeiros, Rommel B; Matos, Aline R; Einicker-Lamas, Marcelo; Tortelote, Giovane G; Vieyra, Adalberto; Costa, Manoel L

    2005-02-01

    The formation of a skeletal muscle fiber begins with the withdrawal of committed mononucleated precursors from the cell cycle. These myoblasts elongate while aligning with each other, guided by recognition between their membranes. This step is followed by cell fusion and the formation of long striated multinucleated myotubes. We used methyl-beta-cyclodextrin (MCD) in primary cultured chick skeletal muscle cells to deplete membrane cholesterol and investigate its role during myogenesis. MCD promoted a significant increase in the expression of troponin T, enhanced myoblast fusion, and induced the formation of large multinucleated myotubes with nuclei being clustered centrally and not aligned at the cell periphery. MCD myotubes were striated, as indicated by sarcomeric alpha-actinin staining, and microtubule and desmin filament distribution was not altered. Pre-fusion MCD-treated myoblasts formed large aggregates, with cadherin and beta-catenin being accumulated in cell adhesion contacts. We also found that the membrane microdomain marker GM1 was not present as clusters in the membrane of MCD-treated myoblasts. Our data demonstrate that cholesterol is involved in the early steps of skeletal muscle differentiation.

  6. Elevated troponin in patients with acute stroke - Is it a true heart attack?

    PubMed

    Dous, George V; Grigos, Angela C; Grodman, Richard

    2017-09-01

    Although the prognostic value of a positive troponin in an acute stroke patient is still uncertain, it is a commonly encountered clinical situation given that Ischemic Heart Disease (IHD) and cerebrovascular disease (CVD) frequently co-exist in the same patient and share similar risk factors. Our objectives in this review are to (1) identify the biologic relationship between acute cerebrovascular stroke and elevated troponin levels, (2) determine the pathophysiologic differences between positive troponin in the setting of acute stroke versus acute myocardial infarction (AMI), and (3) examine whether positive troponin in the setting of acute stroke has prognostic significance. We also will provide an insight analysis of some of the available studies and will provide guidance for a management approach based on the available data according to the current guidelines.

  7. Comparison of four different cardiac troponin assays in patients with end-stage renal disease on chronic haemodialysis.

    PubMed

    Helleskov Madsen, Lene; Ladefoged, Søren; Hildebrandt, Per; Atar, Dan

    2008-01-01

    Several studies have documented the importance of troponin elevation as a prognostic marker in end-stage renal disease (ESRD). The reason for the elevated concentrations is not clarified. We do not know whether the different assays recognize the same patients within ESRD populations. The aim of this study was to compare concentrations of troponin measured by four different assays in a cohort of patients with ESRD, to investigate whether haemodialysis affects troponin concentrations, and to compare the prognostic potential of the different assays. We included 109 patients on chronic haemodialysis. Serum cardiac troponin T (cTnT) was measured pre- and postdialysis using Elecsys 2010 and troponin I (cTnI) using Access AccuTnI, Dimension RxL and AIA-600II. The cTnT assay had the highest percentage of elevated concentrations for all chosen cut-offs with a reduction in percentage of patients with elevated concentrations during haemodialysis. Elecsys 2010 and AIA-600II demonstrated a significant increased mortality with raised concentrations of troponin. The diverging results in previous studies are most likely based on substantial differences in the analytical performance of the assays. The prognostic value of cTnT appears superior to cTnI, which amplifies the prognostic significance of this cardiovascular marker in patients with ESRD.

  8. Anti-troponin I antibodies in renal transplant patients.

    PubMed

    Nunes, José Pedro L; Sampaio, Susana; Cerqueira, Ana; Kaya, Ziya; Oliveira, Nuno Pardal

    2015-02-01

    To characterize the prevalence and clinical correlates of anti-troponin I antibodies in renal transplant patients. A group of 48 consecutive renal transplant patients under immunosuppressive therapy were studied. Anti-troponin I antibodies were measured and clinical data were retrieved. An anti-troponin I antibody titer <1:40 was seen in most patients (30). IgG antibody titers ≥1:80 were seen in eight patients, with a single value of 1:160. Regarding IgM antibodies, in six cases titers ≥1:80 were seen, with one value of 1:320. In only one patient were both anti-troponin I antibody IgG and IgM titers 1:80 or higher. Clinical cardiac disease was seen in nine patients. The presence of an anti-troponin I antibody titer ≥1:80 was not associated with the presence of clinical cardiac disease (p=0.232), but was associated with statin therapy status (p=0.008), being less frequent in patients under statin therapy. Anti-troponin I antibodies are seen in a minority of renal transplant patients, and are not associated with the presence of clinical heart disease, but are associated with lack of statin therapy. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  9. Normal range of serum highly-sensitive troponin-T in patients with chronic kidney disease stage 3-5.

    PubMed

    Chotivanawan, Thunnop; Krittayaphong, Rungroj

    2012-02-01

    Serum troponin-T concentrations are commonly increased in chronic kidney disease (CKD) without acute coronary syndrome. Highly-sensitive troponin-T the new tool that helpful for diagnosis of acute coronary syndrome, provides few data about normal value in patients with chronic kidney disease. The authors studied 89 patients with CKD stage 3-5: 40 had CKD stage 3, 26 had CKD stage 4 and 23 had CKD stage 5. Serum samples were collected for the analysis of highly-sensitive troponin-T levels. The values of highly-sensitive troponin-T of the total group and each CKD stage were presented. The level of highly-sensitive troponin-T in patients with CKD stage 3-5 was 0.044 +/- 0.076 ng/ml. For CKD stages 3, 4 and 5 levels were 0.015 +/- 0.016, 0.043 +/- 0.056, 0.098 +/- 0.121 ng/ml, respectively. 95th percentile of the total group was 0.139 ng/ml. 95th percentile for stage 3, 4 and 5 were 0.052, 0.136, 0.297 ng/ml, respectively. 95th percentile for highly-sensitive troponin-T of patients with CKD stage 3-5 was 0.139 ng/ml. This number may be considered as the cut-off value for diagnosis of acute myocardial infarction.

  10. StructAlign, a Program for Alignment of Structures of DNA-Protein Complexes.

    PubMed

    Popov, Ya V; Galitsyna, A A; Alexeevski, A V; Karyagina, A S; Spirin, S A

    2015-11-01

    Comparative analysis of structures of complexes of homologous proteins with DNA is important in the analysis of DNA-protein recognition. Alignment is a necessary stage of the analysis. An alignment is a matching of amino acid residues and nucleotides of one complex to residues and nucleotides of the other. Currently, there are no programs available for aligning structures of DNA-protein complexes. We present the program StructAlign, which should fill this gap. The program inputs a pair of complexes of DNA double helix with proteins and outputs an alignment of DNA chains corresponding to the best spatial fit of the protein chains.

  11. The Diagnostic Value of Troponin T Level in the Determination of Cardiac Damage in Perinatal Asphyxia Newborns.

    PubMed

    Yildirim, Ali; Ozgen, Fatih; Ucar, Birsen; Alatas, Ozkan; Tekin, Neslihan; Kilic, Zubeyir

    2016-01-01

    Perinatal asphyxia is a clinical condition which results from oxygen deprivation of the fetus or newborn and the breakdown of perfusion in various organs. The aim of this study was to evaluate and compare troponin T levels over time as a marker of cardiac injury in cases of perinatal asphyxia and healthy newborns. The study included a total of 30 newborns diagnosed with perinatal asphyxia with a gestational age of 32-41 weeks, based on the last menstruation date, and 30 healthy newborns with a gestational age of 34-40 weeks, as the control group. Levels of troponin T and creatinin kinase MB were recorded for all participants. No difference was determined between the groups in terms of gestational age, manner of birth, electrocardiographic findings, and PaO2 and PaCO2 values. The umbilical artery pH levels and bicarbonate levels in the study group were found to be statistically lower than those in the control group (p < 0.001). The troponin T and creatinin kinase MB levels in the patients in the study group were higher than those within the control group, at all times. The periods when specificity and sensitivity were highest together for troponin T were the 12th and 24th h. Specificity for troponin T reached the highest value at the 24th h and sensitivity reached the highest value in the cord blood. A positive correlation was found between the troponin T and creatinin kinase MB values at the 6th and 12th h. However, no correlation could be found in the blood between the serum troponin T and creatinin kinase MB levels at the 3rd and 24th h. The troponin T level is a useful test for showing cardiac damage in hypoxic patients in the neonatal period. The sensitivity and specificity of cardiac specific troponin T levels in detecting cardiac damage are much higher according to telecardiography and electrocardiography, while the implementation of the method is simple.

  12. Elevated troponin I levels in acute liver failure: is myocardial injury an integral part of acute liver failure?

    PubMed

    Parekh, Nimisha K; Hynan, Linda S; De Lemos, James; Lee, William M

    2007-06-01

    Although rare instances of cardiac injury or arrhythmias have been reported in acute liver failure (ALF), overall, the heart is considered to be spared in this condition. Troponin I, a sensitive and specific marker of myocardial injury, may be elevated in patients with sepsis and acute stroke without underlying acute coronary syndrome, indicating unrecognized cardiac injury in these settings. We sought to determine whether subclinical cardiac injury might also occur in acute liver failure. Serum troponin I levels were measured in 187 patients enrolled in the US Acute Liver Failure Study Group registry, and correlated with clinical variables and outcomes. Diagnoses were representative of the larger group of >1000 patients thus far enrolled and included 80 with acetaminophen-related injury, 26 with viral hepatitis, 19 with ischemic injury, and 62 others. Overall, 74% of patients had elevated troponin I levels (>0.1 ng/ml). Patients with elevated troponin I levels were more likely to have advanced hepatic coma (grades III or IV) or to die (for troponin I levels >0.1 ng/ml, odds ratio 3.88 and 4.69 for advanced coma or death, respectively). In acute liver failure, subclinical myocardial injury appears to occur more commonly than has been recognized, and its pathogenesis in the context of acute liver failure is unclear. Elevated troponin levels are associated with a significant increase in morbidity and mortality. Measurement of troponin I levels may be helpful in patients with acute liver failure, to detect unrecognized myocardial damage and as a marker of unfavorable outcome.

  13. Structural basis for the regulation of muscle contraction by troponin and tropomyosin.

    PubMed

    Galińska-Rakoczy, Agnieszka; Engel, Patti; Xu, Chen; Jung, Hyunsuk; Craig, Roger; Tobacman, Larry S; Lehman, William

    2008-06-20

    The molecular switching mechanism governing skeletal and cardiac muscle contraction couples the binding of Ca2+ on troponin to the movement of tropomyosin on actin filaments. Despite years of investigation, this mechanism remains unclear because it has not yet been possible to directly assess the structural influence of troponin on tropomyosin that causes actin filaments, and hence myosin-crossbridge cycling and contraction, to switch on and off. A C-terminal domain of troponin I is thought to be intimately involved in inducing tropomyosin movement to an inhibitory position that blocks myosin-crossbridge interaction. Release of this regulatory, latching domain from actin after Ca2+ binding to TnC (the Ca2+ sensor of troponin that relieves inhibition) presumably allows tropomyosin movement away from the inhibitory position on actin, thus initiating contraction. However, the structural interactions of the regulatory domain of TnI (the "inhibitory" subunit of troponin) with tropomyosin and actin that cause tropomyosin movement are unknown, and thus, the regulatory process is not well defined. Here, thin filaments were labeled with an engineered construct representing C-terminal TnI, and then, 3D electron microscopy was used to resolve where troponin is anchored on actin-tropomyosin. Electron microscopy reconstruction showed how TnI binding to both actin and tropomyosin at low Ca2+ competes with tropomyosin for a common site on actin and drives tropomyosin movement to a constrained, relaxing position to inhibit myosin-crossbridge association. Thus, the observations reported reveal the structural mechanism responsible for troponin-tropomyosin-mediated steric interference of actin-myosin interaction that regulates muscle contraction.

  14. X-ray diffraction evidence for myosin-troponin connections and tropomyosin movement during stretch activation of insect flight muscle

    PubMed Central

    Perz-Edwards, Robert J.; Irving, Thomas C.; Baumann, Bruce A. J.; Gore, David; Hutchinson, Daniel C.; Kržič, Uroš; Porter, Rebecca L.; Ward, Andrew B.; Reedy, Michael K.

    2011-01-01

    Stretch activation is important in the mechanical properties of vertebrate cardiac muscle and essential to the flight muscles of most insects. Despite decades of investigation, the underlying molecular mechanism of stretch activation is unknown. We investigated the role of recently observed connections between myosin and troponin, called “troponin bridges,” by analyzing real-time X-ray diffraction “movies” from sinusoidally stretch-activated Lethocerus muscles. Observed changes in X-ray reflections arising from myosin heads, actin filaments, troponin, and tropomyosin were consistent with the hypothesis that troponin bridges are the key agent of mechanical signal transduction. The time-resolved sequence of molecular changes suggests a mechanism for stretch activation, in which troponin bridges mechanically tug tropomyosin aside to relieve tropomyosin’s steric blocking of myosin–actin binding. This enables subsequent force production, with cross-bridge targeting further enhanced by stretch-induced lattice compression and thick-filament twisting. Similar linkages may operate in other muscle systems, such as mammalian cardiac muscle, where stretch activation is thought to aid in cardiac ejection. PMID:21148419

  15. Abnormal troponin I levels in a thalassemia major patient with high ferritin concentration, permanent atrial fibrillation and without acute coronary syndrome.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2010-01-21

    Thalassemia is a congenital hemoglobinopathy leading to anemia because of impaired erythropoiesis and peripheral hemolysis. Thalassemia major patients are transfusion dependent and it results in iron accumulation. The heart is one of the major organs affected with iron overload and iron induced cardiac dysfunction (pump and conduction abnormalities) remains the number one cause of death among thalassemia major patients. It has been reported that a high ferritin concentration is related to high troponin levels in hemodialysis patients receiving more intravenous iron sucrose. Abnormal troponin I levels have also been reported without acute coronary syndrome. We present a case of abnormal troponin I levels in Thalassemia major patient with high ferritin concentration, permanent atrial fibrillation and without acute coronary syndrome. To our knowledge, this is the first report of abnormal troponin I levels in a Thalassemia major patient with high ferritin concentration and without acute coronary syndrome and also this case focuses attention on the importance of the correct evaluation of abnormal troponin I levels. Copyright (c) 2008 Elsevier Ireland Ltd. All rights reserved.

  16. A highly sensitive and selective diagnostic assay based on virus nanoparticles

    NASA Astrophysics Data System (ADS)

    Park, Jin-Seung; Cho, Moon Kyu; Lee, Eun Jung; Ahn, Keum-Young; Lee, Kyung Eun; Jung, Jae Hun; Cho, Yunjung; Han, Sung-Sik; Kim, Young Keun; Lee, Jeewon

    2009-04-01

    Early detection of the protein marker troponin I in patients with a higher risk of acute myocardial infarction can reduce the risk of death from heart attacks. Most troponin assays are currently based on the conventional enzyme linked immunosorbent assay and have detection limits in the nano- and picomolar range. Here, we show that by combining viral nanoparticles, which are engineered to have dual affinity for troponin antibodies and nickel, with three-dimensional nanostructures including nickel nanohairs, we can detect troponin levels in human serum samples that are six to seven orders of magnitude lower than those detectable using conventional enzyme linked immunosorbent assays. The viral nanoparticle helps to orient the antibodies for maximum capture of the troponin markers. High densities of antibodies on the surfaces of the nanoparticles and nanohairs lead to greater binding of the troponin markers, which significantly enhances detection sensitivities. The nickel nanohairs are re-useable and can reproducibly differentiate healthy serum from unhealthy ones. We expect other viral nanoparticles to form similar highly sensitive diagnostic assays for a variety of other protein markers.

  17. Mechanism of the calcium-regulation of muscle contraction — In pursuit of its structural basis —

    PubMed Central

    WAKABAYASHI, Takeyuki

    2015-01-01

    The author reviewed the research that led to establish the structural basis for the mechanism of the calcium-regulation of the contraction of striated muscles. The target of calcium ions is troponin on the thin filaments, of which the main component is the double-stranded helix of actin. A model of thin filament was generated by adding tropomyosin and troponin. During the process to provide the structural evidence for the model, the troponin arm was found to protrude from the calcium-depleted troponin and binds to the carboxyl-terminal region of actin. As a result, the carboxyl-terminal region of tropomyosin shifts and covers the myosin-binding sites of actin to block the binding of myosin. At higher calcium concentrations, the troponin arm changes its partner from actin to the main body of calcium-loaded troponin. Then, tropomyosin shifts back to the position near the grooves of actin double helix, and the myosin-binding sites of actin becomes available to myosin resulting in force generation through actin-myosin interactions. PMID:26194856

  18. Coronary atherosclerosis and adverse outcomes in patients with recent-onset atrial fibrillation and troponin rise.

    PubMed

    Conti, Alberto; Angeli, Elena; Scorpiniti, Margherita; Alesi, Andrea; Trausi, Federica; Lazzeretti, Delia; Padeletti, Luigi; Gensini, Gian Franco

    2015-10-01

    The relationship between troponin and atrial fibrillation (AF) without acute coronary syndrome is still unclear. We sought to investigate the presence of coronary atherosclerosis and adverse outcomes in patients with AF. Consecutive patients with recent-onset AF and without severe comorbidities were enrolled between 2004 and 2013. Patients with a troponin rise or with adverse outcomes were considered for coronary angiography and revascularization when "critical" stenosis (≥70%) was recognized. Propensity score matching was performed to adjust for baseline characteristics; after matching, no differences existed between the groups of patients with or without troponin rise. The primary end point was the composite of acute coronary syndrome, revascularization, and cardiac death at 1- and 12-month follow-ups. Of 3627 patients enrolled, 3541 completed the study; 202 (6%) showed troponin rise; and 91 (3%), an adverse outcome. In the entire cohort, on multivariate analysis, the odds ratio for the occurrence of the primary end point of troponin rise was 14 (95% confidence interval [CI], 10-23; P<.001), and that of known coronary artery disease was 3 (CI, 2-5; P=.001). In the matching cohort, the odds ratio of troponin rise was 10 (CI, 4-22; P<.001), and that of TIMI score greater than 2 was 4 (CI, 2-9; P≤.001). In the entire cohort, patients with or without troponin rise achieved the primary end point in 38 (19%) and 43 (1%) patients, respectively (P<.001). Stroke occurred in 4 (2%) and 20 (1%), respectively (P=.018). Critical stenosis and revascularization account for 23 (12%) and 15 (1%), respectively (P<.001). In the matching cohort, results were confirmed, but incidence of stroke was comparable. Patients with recent-onset AF and troponin rise showed higher prevalence of coronary atherosclerosis and adverse cardiac events. Stroke per se did not succeed in justifying the high morbidity. Thus, beyond stroke, coronary atherosclerosis might have a pivotal role in poor outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Highly increased Troponin I levels following high-intensity endurance cycling may detect subclinical coronary artery disease in presumably healthy leisure sport cyclists: The North Sea Race Endurance Exercise Study (NEEDED) 2013.

    PubMed

    Skadberg, Øyvind; Kleiven, Øyunn; Bjørkavoll-Bergseth, Magnus; Melberg, Tor; Bergseth, Rolf; Selvåg, Jone; Auestad, Bjørn; Greve, Ole J; Dickstein, Kenneth; Aarsland, Torbjørn; Ørn, Stein

    2017-05-01

    Background Circulating cardiac troponin levels increase following prolonged intense physical exercise. The aim of this study was to identify participants with highly elevated cardiac troponins after prolonged, high intensity exercise, and to evaluate these for subclinical coronary artery disease. Methods and results Ninety-seven recreational cyclists without known cardiovascular disease or diabetes, participating in a 91 km mountain bike race were included, 74 (76%) were males, age: 43 ± 10 years, race duration: 4.2 (3.6-4.7) h. Blood samples, rest electrocardiogram and physical examination were obtained 24 h prior to, and at 0, 3 and 24 h following the race. Median cardiac troponin I level at baseline: 3.4 (2.1-4.9) ng/l (upper limit of normal: 30.0 ng/l). There was a highly significant ( p < 0.0001) increase in circulating cardiac troponin I in all participants: immediately following the race; 50.5 (28.5-71.9) ng/l, peaking at 3 h 69.3 (42.3-97.7) ng/l and declining at 24 h: 14.2 (8.5-27.9) ng/l. No cyclist had symptoms or rest electrocardiogram changes compatible with coronary artery disease during or following the race. Coronary artery disease was detected by coronary angiography in the three cyclists with the three of the four highest cardiac troponin values (>370 ng/l) at 3 and 24 h following the race. Computed tomographic coronary angiography was performed in an additional 10 riders with the subsequently highest cardiac troponin I values, without identifying underlying coronary artery disease. Conclusions This study suggests that there is a pathologic cardiac troponin I response following exercise in individuals with subclinical coronary artery disease. This response may be associated with an excessive cardiac troponin I increase at 3 and 24 h following prolonged high-intensity exercise.

  20. Causes of Troponin Elevation and Associated Mortality in Young Patients.

    PubMed

    Wu, Candace; Singh, Avinainder; Collins, Bradley; Fatima, Amber; Qamar, Arman; Gupta, Ankur; Hainer, Jon; Klein, Josh; Jarolim, Petr; Di Carli, Marcelo; Nasir, Khurram; Bhatt, Deepak L; Blankstein, Ron

    2018-03-01

    While increased serum troponin levels are often due to myocardial infarction, increased levels may also be found in a variety of other clinical scenarios. Although these causes of troponin elevation have been characterized in several studies in older adults, they have not been well characterized in younger individuals. We conducted a retrospective review of patients 50 years of age or younger who presented with elevated serum troponin levels to 2 large tertiary care centers between January 2000 and April 2016. Patients with prior known coronary artery disease were excluded. The cause of troponin elevation was adjudicated via review of electronic medical records. All-cause death was determined using the Social Security Administration's death master file. Of the 6081 cases meeting inclusion criteria, 3574 (58.8%) patients had a myocardial infarction, while 2507 (41.2%) had another cause of troponin elevation. Over a median follow-up of 8.7 years, all-cause mortality was higher in patients with nonmyocardial infarction causes of troponin elevation compared with those with myocardial infarction (adjusted hazard ratio [HR] 1.30; 95% confidence interval [CI], 1.15-1.46; P < .001). Specifically, mortality was higher in those with central nervous system pathologies (adjusted HR 2.21; 95% CI, 1.85-2.63; P < .001), nonischemic cardiomyopathies (adjusted HR 1.66; 95% CI, 1.37-2.02; P < .001), and end-stage renal disease (adjusted HR 1.36; 95% CI, 1.07-1.73; P = .013). However, mortality was lower in patients with myocarditis compared with those with an acute myocardial infarction (adjusted HR 0.43; 95% CI:, 0.31-0.59; P < .001). There is a broad differential for troponin elevation in young patients, which differs based on demographic features. Most nonmyocardial infarction causes of troponin elevation are associated with higher all-cause mortality compared with acute myocardial infarction. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Relation between troponin T concentration and mortality in patients presenting with an acute stroke: observational study

    PubMed Central

    James, P; Ellis, C J; Whitlock, R M L; McNeil, A R; Henley, J; Anderson, N E

    2000-01-01

    Objective To assess whether a raised serum troponin T concentration would be an independent predictor of death in patients with an acute ischaemic stroke. Design Observational study. Setting Auckland Hospital, Auckland, New Zealand. Subjects All 181 patients with an acute ischaemic stroke admitted over nine months in 1997-8, from a total of 8057 patients admitted to the acute medical service. Main outcome measures Blood samples for measuring troponin T concentration were collected 12-72 hours after admission; other variables previously associated with severity of stroke were also recorded and assessed as independent predictors of inpatient mortality. Results Troponin T concentration was raised (>0.1 μg/l) in 17% (30) of patients admitted with an acute ischaemic stroke. Thirty one patients died in hospital (12/30 (40%) patients with a raised troponin T concentration v 19/151 (13%) patients with a normal concentration (relative risk 3.2 (95% confidence 1.7 to 5.8; P=0.0025)). Of 17 possible predictors of death, assessed in a multivariate stepwise model, only a raised troponin T concentration (P=0.0002), age (P=0.0008), and an altered level of consciousness at presentation (P=0.0074) independently predicted an adverse outcome. Conclusions Serum troponin T concentration at hospital admission is a powerful predictor of mortality in patients admitted with an acute ischaemic stroke. PMID:10834890

  2. 5A.01: CORONARY ATHEROSCLEROSIS AND ADVERSE OUTCOME IN HYPERTENSIVE PATIENTS WITH RECENT-ONSET ATRIAL FIBRILLATION AND TROPONIN RISE.

    PubMed

    Conti, A; Angeli, E; Trausi, F; Grifoni, C; Lazzeretti, D; Bianchi, S; Catarzi, S; Covelli, A; Perrotta, M E; Lencioni, A M; Pisani, N; Bertolini, L

    2015-06-01

    Atrial fibrillation (AF), the most common cardiac-arrhythmia in critical-care, has reached a high prevalence in hypertensive patients. Prevention of systemic-embolism is mandatory; unfortunately, evidence to support the treatment of comorbidities as coronary artery disease (CAD) that contribute to excess mortality is lacking, and the mechanism underlying the troponin-rise during AF without acute coronary syndrome (ACS) is unclear. This study investigates the relationship between CAD, stroke and outcomes in patients with troponin-rise and AF. Patients with a recent-onset AF and without severe comorbidities were enrolled. Baseline characteristics in those with troponin-rise versus those without were adjusted with propensity-score-matching for possible confounders. SPSS-software allowed estimation of the propensity-score using logistic-regression and specifying nearest-neighbor matching in prior-stroke, heart-rate, hypertension, TIMI-risk-score, GRACE-score, CHA2DS2Vasc-score. Patients with a troponin-rise or cardiovascular event (CVE) were considered for angiography. The primary endpoint was the composite of ACS, revascularization (with critical CAD>/ = 70%) and cardiac-death at the follow-up; the secondary endpoint was stroke. Out of 6203 AF patients without severe comorbidities, 3541 with recent-onset AF completed the study; 202(6%) showed a troponin-rise, 91(3%) a CVE. After matching no difference existed in baseline characteristics. On multivariate analysis, in the entire cohort, troponin-rise, know-CAD and hypertension were predictors of the endpoint, whereas only troponin-rise (Odd Ratio, OR: 10, Confidence Interval 95%, CI: 4-22, p < 0.001) and TIMI-score > 2 (OR 4, CI 2-9, p < 0.001) in the matching cohort, suggesting the role of CAD in poor outcomes. Patients with or without troponin-rise achieved the endpoint in 38(19%) and 43(1%), respectively (p < 0.001). Stroke occurred in 4(2%) and 20 (1%), respectively (p = 0.018). Critical CAD account for 23(12%) and 15(1%), respectively (p < 0,001). In the matching cohort, only stroke did not reach the statistical significance. Interestingly, the best cut/off troponin level for decision-making was 0.30 ng/L which, on Receiver Operator Curve analysis, was associated with 68% of sensitivity and 60% specificity; the value > 0.50 ng/L with 55% and 75%, respectively. Patients with a recent-onset AF and troponin-rise showed a high prevalence of CVE but not stroke, thus CAD might have a role in poor outcomes.

  3. Troponin elevation in severe sepsis and septic shock: the role of left ventricular diastolic dysfunction and right ventricular dilatation*.

    PubMed

    Landesberg, Giora; Jaffe, Allan S; Gilon, Dan; Levin, Phillip D; Goodman, Sergey; Abu-Baih, Abed; Beeri, Ronen; Weissman, Charles; Sprung, Charles L; Landesberg, Amir

    2014-04-01

    Serum troponin concentrations predict mortality in almost every clinical setting they have been examined, including sepsis. However, the causes for troponin elevations in sepsis are poorly understood. We hypothesized that detailed investigation of myocardial dysfunction by echocardiography can provide insight into the possible causes of troponin elevation and its association with mortality in sepsis. Prospective, analytic cohort study. Tertiary academic institute. A cohort of ICU patients with severe sepsis or septic shock. Advanced echocardiography using global strain, strain-rate imaging and 3D left and right ventricular volume analyses in addition to the standard echocardiography, and concomitant high-sensitivity troponin-T measurement in patients with severe sepsis or septic shock. Two hundred twenty-five echocardiograms and concomitant high-sensitivity troponin-T measurements were performed in a cohort of 106 patients within the first days of severe sepsis or septic shock (2.1 ± 1.4 measurements/patient). Combining echocardiographic and clinical variables, left ventricular diastolic dysfunction defined as increased mitral E-to-strain-rate e'-wave ratio, right ventricular dilatation (increased right ventricular end-systolic volume index), high Acute Physiology and Chronic Health Evaluation-II score, and low glomerular filtration rate best correlated with elevated log-transformed concomitant high-sensitivity troponin-T concentrations (mixed linear model: t = 3.8, 3.3, 2.8, and -2.1 and p = 0.001, 0.0002, 0.006, and 0.007, respectively). Left ventricular systolic dysfunction determined by reduced strain-rate s'-wave or low ejection fraction did not significantly correlate with log(concomitant high-sensitivity troponin-T). Forty-one patients (39%) died in-hospital. Right ventricular end-systolic volume index and left ventricular strain-rate e'-wave predicted in-hospital mortality, independent of Acute Physiology and Chronic Health Evaluation-II score (logistic regression: Wald = 8.4, 6.6, and 9.8 and p = 0.004, 0.010, and 0.001, respectively). Concomitant high-sensitivity troponin-T predicted mortality in univariate analysis (Wald = 8.4; p = 0.004), but not when combined with right ventricular end-systolic volume index and strain-rate e'-wave in the multivariate analysis (Wald = 2.3, 4.6, and 6.2 and p = 0.13, 0.032, and 0.012, respectively). Left ventricular diastolic dysfunction and right ventricular dilatation are the echocardiographic variables correlating best with concomitant high-sensitivity troponin-T concentrations. Left ventricular diastolic and right ventricular systolic dysfunction seem to explain the association of troponin with mortality in severe sepsis and septic shock.

  4. [Diagnostic value of cardiac troponin T increase in critically ill patients].

    PubMed

    Koshkina, E V; Krasnosel'skiĭ, M Ia; Fedorovskiĭ, N M; Goriacheva, E V; Polupan, A A; Aref'ev, A A; Katrukha, A G

    2009-01-01

    There are presently reports on elevated levels of cardiac troponins in patients without acute myocardial infarction (AMI). The objective of this investigation was to study the diagnostic value of increased blood cardiac troponin T levels in patients without its clinical picture and ECG changes characteristic of AMI. The study covered 72 patients (48 males and 24 females) aged 54 to 87 years (mean 69.8 +/- 11.2 years). The inclusion criteria were increased cardiac troponin T; the main exclusion criteria were AMI-typical anginal pain and characteristic ECG changes (ST-segment elevation, the appearance of pathological Q waves). The final diagnosis of AMI was established in only 29 (40.3%) patients; the other 43 patients were diagnosed as having the following diseases: septic state in 21; oncopathology in 10; diabetic nephropathy with chronic renal failure in 6; brain infarct in 4; and B12 deficiency anemia in 2. In dead patients, the level of troponin T was significantly higher than that in discharged patients, respective of the underlying disease. There was a direct correlation between the cardiac troponin T levels and the SAPS II index that reflected the severity of a patient's general condition (r = 0.44; p = 0.0001) and an inverse correlation between the cardiac troponin level and the left ventricular ejection fraction (r = -0.45; p = 0.003). Thus, despite the cardiospecificity of troponin T, its detection in the blood of critically ill patients without other manifestations of AMI is not a specific symptom of AMI, but it is suggestive of the severity of the disease, probably with the involvement of the myocardium into the pathological process.

  5. Short-term increase of serum troponin I and serum heart-type fatty acid-binding protein (H-FABP) in dogs following administration of formoterol.

    PubMed

    Strauss, Volker; Wöhrmann, Thomas; Frank, Ilona; Hübel, Ulrich; Luft, Jörg; Bode, Gerd; Germann, Paul-Georg

    2010-07-01

    In this paper, changes in serum levels of the cardiac biomarkers troponin I and the heart-type fatty acid-binding protein (H-FABP) following administration of a long-acting beta(2)-sympathicomimeticum (long-acting beta-agonist, LABA) to dogs were measured. We measured troponin I in dogs in a 4-week repeated-dose study with inhalative administration of formoterol (13microg/kgd) and a glucocorticoid/formoterol combination (143/16microg/kgd). The medians of troponin I increased within 3 days in both groups, far beyond the cut-off level (0.1microg/L), but returned to baseline levels on study day 9. The increase was more pronounced in the formoterol-only group (3.29microg/L) compared to the glucocorticoid/formoterol combination group (1.32microg/L). In a second study, we measured serum troponin I as well as serum H-FABP levels in several samples over 7 days in dogs, receiving a single inhalative dose of a glucocorticoid/formoterol combination (120/12mug/kgd). The median of the troponin I concentration increased above the cut-off level within 2h and that of H-FABP within 4h. The medians of both parameters were temporarily above the cut-off levels even on study day 7. Both studies were conducted according to national animal welfare guidelines. To our knowledge, this is the first report that shows a corresponding increase of troponin I and H-FABP in dogs treated with formoterol. Both parameters are more sensitive in detecting a drug-induced cardiac injury compared to total LDH, total CK as well as CK MB activity. However, it is recommended to take at least three blood samples per day to assess a temporary increase of troponin I.

  6. FET-biosensor for cardiac troponin biomarker

    NASA Astrophysics Data System (ADS)

    Arshad, Mohd Khairuddin Md; Faris Mohamad Fathil, Mohamad; Hashim, Uda

    2017-11-01

    Acute myocardial infarction or myocardial infarction (MI) is a major health problem, due to diminished flow of blood to the heart, leads to higher rates of mortality and morbidity. The most specific markers for cardiac injury are cardiac troponin I (cTnI) and cardiac troponin T (cTnT) which have been considered as `gold standard'. Due to higher specificity, determination of the level of cardiac troponins became a predominant indicator for MI. Currently, field-effect transistor (FET)-based biosensors have been main interest to be implemented in portable sensors with the ultimate application in point-of-care testing (POCT). In this paper, we review on the FET-based biosensor based on its principle of operation, integration with nanomaterial, surface functionalization as well as immobilization, and the introduction of additional gate (for ambipolar conduction) on the device architecture for the detection of cardiac troponin I (cTnI) biomarker.

  7. Multiple Species Comparison of Cardiac Troponin T and Dystrophin: Unravelling the DNA behind Dilated Cardiomyopathy.

    PubMed

    England, Jennifer; Loughna, Siobhan; Rutland, Catrin Sian

    2017-07-07

    Animals have frequently been used as models for human disorders and mutations. Following advances in genetic testing and treatment options, and the decreasing cost of these technologies in the clinic, mutations in both companion and commercial animals are now being investigated. A recent review highlighted the genes associated with both human and non-human dilated cardiomyopathy. Cardiac troponin T and dystrophin were observed to be associated with both human and turkey (troponin T) and canine (dystrophin) dilated cardiomyopathies. This review gives an overview of the work carried out in cardiac troponin T and dystrophin to date in both human and animal dilated cardiomyopathy.

  8. High sensitivity-troponin elevation secondary to non-coronary diagnoses and death and recurrent myocardial infarction: An examination against criteria of causality.

    PubMed

    Chew, Derek P; Briffa, Tom G; Alhammad, Nasser J; Horsfall, Matt; Zhou, Julia; Lou, Pey W; Coates, Penelope; Scott, Ian; Brieger, David; Quinn, Stephen J; French, John

    2015-10-01

    Myonecrosis provoked by illness unrelated to unstable coronary plaque is common, but uncertainty about a cause-effect relationship with future events challenges the appropriateness of initiating therapies known to be effective in cardiac conditions. We examined the causal relationship between troponin elevation in non-coronary diagnoses and late cardiac events using the Bradford Hills criteria for causality. Patients presenting acutely to South Australian public hospitals receiving at least one troponin between September 2011-September 2012 were included. Diagnoses were classified as coronary, non-coronary cardiac and non-cardiac using the International Classification of Diseases, version 10 Australian Modified, codes. The relationship between peak in-hospital troponin, using a high-sensitivity troponin T assay and adjudicated cardiac and non-cardiac mortality, and subsequent myocardial infarction (MI) was assessed using competing-risk flexible parametric survival models. Troponin results were available for 38,161 patients of whom, 12,645 (33.6%), 3237 (8.5%), and 22,079 (57.9%) patients were discharged with coronary, non-coronary cardiac and non-cardiac diagnoses, respectively. Troponin >14 ng/l was observed in 43.6%. The relationship between troponin and cardiac mortality was stronger among the non-coronary diagnosis group (troponin 1000 ng/l: coronary hazard ratio: 5.1 (95% confidence interval (CI) 4.0-6.6) vs non-coronary hazard ratio: 16.3 (95% CI 12.6-22.4)). The temporal hazard for cardiac death was marked within 30 days in both groups. Among non-coronary diagnoses, the hazard for recurrent MI was higher but did not vary with time. Consistency with causal criteria between secondary myonecrosis and cardiac events suggest the potential benefit for extending cardiac specific interventions to this population if supported in trials appropriately designed to address competing risks. Troponin elevation precipitated by non-coronary events is common and demonstrates an associations with late mortality that are analogous to spontaneous MI resulting from unstable coronary plaque. These observations help inform the design of randomized clinical trials exploring the benefits and risk of therapies with established benefits in other cardiac conditions. Such studies will need to appropriately account for competing risks in this population of patients. © The European Society of Cardiology 2014.

  9. Quantitative troponin and death, cardiogenic shock, cardiac arrest and new heart failure in patients with non-ST-segment elevation acute coronary syndromes (NSTE ACS): insights from the Global Registry of Acute Coronary Events.

    PubMed

    Jolly, Sanjit S; Shenkman, Heather; Brieger, David; Fox, Keith A; Yan, Andrew T; Eagle, Kim A; Steg, P Gabriel; Lim, Ki-Dong; Quill, Ann; Goodman, Shaun G

    2011-02-01

    The objective of this study was to determine if the extent of quantitative troponin elevation predicted mortality as well as in-hospital complications of cardiac arrest, new heart failure and cardiogenic shock. 16,318 patients with non-ST-segment elevation acute coronary syndromes (NSTE ACS) from the Global Registry of Acute Coronary Events (GRACE) were included. The maximum 24 h troponin value as a multiple of the local laboratory upper limit of normal was used. The population was divided into five groups based on the degree of troponin elevation, and outcomes were compared. An adjusted analysis was performed using quantitative troponin as a continuous variable with adjustment for known prognostic variables. For each approximate 10-fold increase in the troponin ratio, there was an associated increase in cardiac arrest, sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) (1.0, 2.4, 3.4, 5.9 and 13.4%; p<0.001 for linear trend), cardiogenic shock (0.5, 1.4, 2.0, 4.4 and 12.7%; p<0.001), new heart failure (2.5, 5.1, 7.4, 11.6 and 15.8%; p<0.001) and mortality (0.8, 2.2, 3.0, 5.3 and 14.0%; p<0.001). These findings were replicated using the troponin ratio as a continuous variable and adjusting for covariates (cardiac arrest, sustained VT or VF, OR 1.56, 95% CI 1.39 to 1.74; cardiogenic shock, OR 1.87, 95% CI 1.61 to 2.18; and new heart failure, OR 1.57, 95% CI 1.45 to 1.71). The degree of troponin elevation was predictive of early mortality (HR 1.61, 95% CI 1.44 to 1.81; p<0.001 for days 0-14) and longer term mortality (HR 1.18, 95% CI 1.07 to 1.30, p=0.001 for days 15-180). The extent of troponin elevation is an independent predictor of morbidity and mortality.

  10. Comparison of cardiac troponins I and T measured with high-sensitivity methods for evaluation of prognosis in atrial fibrillation: an ARISTOTLE substudy.

    PubMed

    Hijazi, Ziad; Siegbahn, Agneta; Andersson, Ulrika; Lindahl, Bertil; Granger, Christopher B; Alexander, John H; Atar, Dan; Gersh, Bernard J; Hanna, Michael; Harjola, Veli-Pekka; Horowitz, John; Husted, Steen; Hylek, Elaine M; Lopes, Renato D; McMurray, John J V; Wallentin, Lars

    2015-02-01

    Although cardiac troponin is associated with outcomes in atrial fibrillation (AF), the complementary prognostic information provided by cardiac troponin I (cTnI) and cTnT is unknown. This study investigated the distribution, determinants, and prognostic value of cTnI and cTnT concentrations in patients with AF. Samples were collected. At the time of randomization, we analyzed cTnI and cTnT concentrations of 14806 AF patients in the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) trial using high-sensitivity assays. Correlations (Spearman), determinants (multivariable linear regression), and outcomes (adjusted Cox models and c-statistics) were investigated. Concentrations of cTnI and cTnT were correlated (r = 0.70) and measurable in most participants [cTnI 98.5% (median 5.4 ng/L, ≥99th percentile in 9.2%) and cTnT 93.5% (median 10.9 ng/L, ≥99th percentile in 34.4%)]. Renal impairment was the most important factor affecting the concentrations of both troponins. cTnI increase was more associated with heart failure, vascular disease, and persistent/permanent AF, and cTnT with age, male sex, and diabetes. Over a median 1.9 years of follow-up, patients with both troponins above the median had significantly higher risk for stroke/systemic embolism [hazard ratio (HR) 1.72 (95% CI 1.31-2.27)], cardiac death [3.14 (2.35-4.20)], and myocardial infarction [2.99 (1.78-5.03)] than those with both troponins below median (all P < 0.005). Intermediate risks were observed when only 1 troponin was above the median. When combined with clinical information, each marker provided similar prognostication and had comparable c-index. cTnI and cTnT concentrations are moderately correlated and measurable in plasma of most AF patients. The risk of stroke and cardiovascular events is highest when both troponins are above median concentrations. Each troponin provides comparable prognostic information when combined with clinical risk factors. ClinicalTrials.gov/NCT00412984. © 2014 American Association for Clinical Chemistry.

  11. Multiple Species Comparison of Cardiac Troponin T and Dystrophin: Unravelling the DNA behind Dilated Cardiomyopathy

    PubMed Central

    England, Jennifer

    2017-01-01

    Animals have frequently been used as models for human disorders and mutations. Following advances in genetic testing and treatment options, and the decreasing cost of these technologies in the clinic, mutations in both companion and commercial animals are now being investigated. A recent review highlighted the genes associated with both human and non-human dilated cardiomyopathy. Cardiac troponin T and dystrophin were observed to be associated with both human and turkey (troponin T) and canine (dystrophin) dilated cardiomyopathies. This review gives an overview of the work carried out in cardiac troponin T and dystrophin to date in both human and animal dilated cardiomyopathy. PMID:29367539

  12. A Spatially Detailed Model of Isometric Contraction Based on Competitive Binding of Troponin I Explains Cooperative Interactions between Tropomyosin and Crossbridges

    PubMed Central

    Land, Sander; Niederer, Steven A.

    2015-01-01

    Biophysical models of cardiac tension development provide a succinct representation of our understanding of force generation in the heart. The link between protein kinetics and interactions that gives rise to high cooperativity is not yet fully explained from experiments or previous biophysical models. We propose a biophysical ODE-based representation of cross-bridge (XB), tropomyosin and troponin within a contractile regulatory unit (RU) to investigate the mechanisms behind cooperative activation, as well as the role of cooperativity in dynamic tension generation across different species. The model includes cooperative interactions between regulatory units (RU-RU), between crossbridges (XB-XB), as well more complex interactions between crossbridges and regulatory units (XB-RU interactions). For the steady-state force-calcium relationship, our framework predicts that: (1) XB-RU effects are key in shifting the half-activation value of the force-calcium relationship towards lower [Ca2+], but have only small effects on cooperativity. (2) XB-XB effects approximately double the duty ratio of myosin, but do not significantly affect cooperativity. (3) RU-RU effects derived from the long-range action of tropomyosin are a major factor in cooperative activation, with each additional unblocked RU increasing the rate of additional RU’s unblocking. (4) Myosin affinity for short (1–4 RU) unblocked stretches of actin of is very low, and the resulting suppression of force at low [Ca2+] is a major contributor in the biphasic force-calcium relationship. We also reproduce isometric tension development across mouse, rat and human at physiological temperature and pacing rate, and conclude that species differences require only changes in myosin affinity and troponin I/troponin C affinity. Furthermore, we show that the calcium dependence of the rate of tension redevelopment ktr is explained by transient blocking of RU’s by a temporary decrease in XB-RU effects. PMID:26262582

  13. Selectivity verification of cardiac troponin monoclonal antibodies for cardiac troponin detection by using conventional ELISA

    NASA Astrophysics Data System (ADS)

    Fathil, M. F. M.; Arshad, M. K. Md; Gopinath, Subash C. B.; Adzhri, R.; Ruslinda, A. R.; Hashim, U.

    2017-03-01

    This paper presents preparation and characterization of conventional enzyme-linked immunosorbent assay (ELISA) for cardiac troponin detection to determine the selectivity of the cardiac troponin monoclonal antibodies. Monoclonal antibodies, used to capture and bind the targets in this experiment, are cTnI monoclonal antibody (MAb-cTnI) and cTnT monoclonal antibody (MAb-cTnT), while both cardiac troponin I (cTnI) and T (cTnT) are used as targets. ELISA is performed inside two microtiter plates for MAb-cTnI and MAb-cTnT. For each plate, monoclonal antibodies are tested by various concentrations of cTnI and cTnT ranging from 0-6400 µg/l. The binding selectivity and level of detection between monoclonal antibodies and antigen are determined through visual observation based on the color change inside each well on the plate. ELISA reader is further used to quantitatively measured the optical density of the color changes, thus produced more accurate reading. The results from this experiment are utilized to justify the use of these monoclonal antibodies as bio-receptors for cardiac troponin detection by using field-effect transistor (FET)-based biosensors coupled with substrate-gate in the future.

  14. Cloning of a newly identified heart-specific troponin I isoform, which lacks the troponin T binding portion, using the yeast hybrid system.

    PubMed

    Suzuki, Hideaki; Arakawa, Yasuhiro; Ito, Masaki; Yamada, Hisashi; Horiguchi-Yamada, Junko

    2006-01-01

    To elucidate the molecular pathogenesis behind increased levels of laminin in cardiac muscle cells in cardiomyopathy by using a yeast hybrid screen. The present study reports the cloning of a newly identified heart-specific troponin I isoform, which is putatively linked to laminin. Future studies will explore the functional significance of this connection. Yeast two-hybrid screen analysis was performed using MLF1-interacting protein (amino acids 1 to 318) as bait. The human heart complementary DNA library was screened by using the yeast-mating method for overnight culture. Two final positive clones from the heart library were isolated. These two clones encoded the same protein, a short isoform of human cardiac troponin I (TnI) that lacked TnI exons 5 and 6. The TnI isoform has a heart-specific expression pattern and it shares several sequence features with human cardiac TnI; however, it lacks the troponin T binding portion. The heart-specific segment of the human cardiac TnI isoform shares several sequence features with human cardiac TnI, but it lacks the troponin T binding portion. These results suggest that the heart-specific TnI isoform may be involved in cardiac development and disease.

  15. Cloning of a newly identified heart-specific troponin I isoform, which lacks the troponin T binding portion, using the yeast hybrid system

    PubMed Central

    Suzuki, Hideaki; Arakawa, Yasuhiro; Ito, Masaki; Yamada, Hisashi; Horiguchi-Yamada, Junko

    2006-01-01

    OBJECTIVE To elucidate the molecular pathogenesis behind increased levels of laminin in cardiac muscle cells in cardiomyopathy by using a yeast hybrid screen. The present study reports the cloning of a newly identified heart-specific troponin I isoform, which is putatively linked to laminin. Future studies will explore the functional significance of this connection. METHODS Yeast two-hybrid screen analysis was performed using MLF1-interacting protein (amino acids 1 to 318) as bait. The human heart complementary DNA library was screened by using the yeast-mating method for overnight culture. RESULTS Two final positive clones from the heart library were isolated. These two clones encoded the same protein, a short isoform of human cardiac troponin I (TnI) that lacked TnI exons 5 and 6. The TnI isoform has a heart-specific expression pattern and it shares several sequence features with human cardiac TnI; however, it lacks the troponin T binding portion. CONCLUSION The heart-specific segment of the human cardiac TnI isoform shares several sequence features with human cardiac TnI, but it lacks the troponin T binding portion. These results suggest that the heart-specific TnI isoform may be involved in cardiac development and disease. PMID:18651010

  16. Cardiac troponin I degradation in serum of patients with hypertrophic obstructive cardiomyopathy undergoing percutaneous septal ablation.

    PubMed

    Madsen, Lene H; Lund, Terje; Grieg, Zanina; Nygaard, Ståle; Holmvang, Lene; Jurlander, Birgit; Grande, Peer; Christensen, Geir; Atar, Dan

    2009-01-01

    Troponin has become the most important marker for diagnosing acute myocardial infarction, yet knowledge is scarce regarding appearance of specific degradation fragments in the blood. We have recently described the appearance of intact cardiac troponin I (cTnI) and 7 degradation products in patients suffering from ST-elevation myocardial infarction (STEMI) using Western blot analysis. However, the time resolution in STEMI patients is hampered by the rather vague time point 'onset of pain'. We therefore sought to utilize a time-wise more reliable model of human myocardial necrosis: percutaneous transluminal septal myocardial ablation (PTSMA) of hypertrophic obstructive cardiomyopathy (HOCM). Here the iatrogenic induction of myocardial necrosis occurs in vivo, allowing us to investigate degradation of cTnI by the second. Blood samples were obtained from 8 patients with HOCM just prior to initiation of PTSMA and up to 50 h following the procedure. Western blot analysis was performed with subsequent analysis of relative intensities of the bands as compared to the degradation of cTnI in STEMI patients from the ASSENT-2 troponin substudy. We demonstrate intact cTnI and 9 degradation products [molecular weight (MW) 12.0-23.5 kDa]. The bands were comparable in MW to degradation fragments in STEMI. Their early rise in intensity, occurring within few minutes after the alcohol injection, emphasizes how susceptible troponin bands are to chemical/ischemic insults. Moreover, two additional bands were visible in the PTSMA population. This work describes the degradation products of troponin I in HOCM patients undergoing PTSMA. The detected bands appear fast and are similar to degradations following STEMI. This model contributes to our knowledge of the degradation patterns of troponin in disease states, and may thus play a role in the interpretation of elevated troponin levels. Copyright 2009 S. Karger AG, Basel.

  17. N-terminal pro-brain natriuretic peptide and high-sensitivity troponin in the evaluation of acute chest pain of uncertain etiology. A PITAGORAS substudy.

    PubMed

    Sanchis, Juan; Bardají, Alfredo; Bosch, Xavier; Loma-Osorio, Pablo; Marín, Francisco; Sánchez, Pedro L; Calvo, Francisco; Avanzas, Pablo; Hernández, Carolina; Serrano, Silvia; Carratalá, Arturo; Barrabés, José A

    2013-07-01

    High-sensitivity troponin assays have improved the diagnosis of acute coronary syndrome in patients presenting with chest pain and normal troponin levels as measured by conventional assays. Our aim was to investigate whether N-terminal pro-brain natriuretic peptide provides additional information to troponin determination in these patients. A total of 398 patients, included in the PITAGORAS study, presenting to the emergency department with chest pain and normal troponin levels as measured by conventional assay in 2 serial samples (on arrival and 6 h to 8h later) were studied. The samples were also analyzed in a central laboratory for high-sensitivity troponin T (both samples) and for N-terminal pro-brain natriuretic peptide (second sample). The endpoints were diagnosis of acute coronary syndrome and the composite endpoint of in-hospital revascularization or a 30-day cardiac event. Acute coronary syndrome was adjudicated to 79 patients (20%) and the composite endpoint to 59 (15%). When the N-terminal pro-brain natriuretic peptide quartile increased, the diagnosis of acute coronary syndrome also increased (12%, 16%, 23% and 29%; P=.01), as did the risk of the composite endpoint (6%, 13%, 16% and 24%; P=.004). N-terminal pro-brain natriuretic peptide elevation (>125ng/L) was associated with both endpoints (relative risk= 2.0; 95% confidence interval, 1.2-3.3; P=.02; relative risk=2.4; 95% confidence interval, 1.4-4.2; P=.004). However, in the multivariable models adjusted by clinical and electrocardiographic data, a predictive value was found for high-sensitivity T troponin but not for N-terminal pro-brain natriuretic peptide. In low-risk patients with chest pain of uncertain etiology evaluated using high-sensitivity T troponin, N-terminal pro-brain natriuretic peptide does not contribute additional predictive value to diagnosis or the prediction of short-term outcomes. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  18. Troponin Limit of Detection Plus Cardiac Risk Stratification Scores to Rule Out Acute Myocardial Infarction and 30-Day Major Adverse Cardiac Events in ED Patients.

    PubMed

    Datlow, Mitchell D; Gray, Kelly M; Watts, Adriel; Diercks, Deborah B; Mumma, Bryn E

    2017-12-01

    When screening for acute myocardial infarction (AMI), troponin levels below the 99th percentile, including those below the limit of detection (LOD), are considered normal. We hypothesized that a low-risk HEART score (0-3) or ACS Pretest Probability Assessment <2% plus a single troponin below the LOD would rule out both AMI and 30-day major adverse cardiac events (MACE). We studied all patients who presented to a single academic emergency department and received a troponin I (Siemens Ultra Troponin I) from September 1, 2013, to November 13, 2013 (n=888). Demographic and clinical data were abstracted from the electronic medical record. Primary outcome was a final encounter diagnosis of myocardial infarction. Secondary outcome was 30-day MACE, defined as composite of myocardial infarction, revascularization, or death from a cardiac or uncertain etiology. Sensitivities of low-risk HEART score and ACS Pretest Probability <2% alone were 98% (95% confidence interval [CI], 89%-100%) and 96% (95% CI, 86%-100%) for AMI and 94% (95% CI, 86%-98%) and 95% (95% CI, 88%-99%), respectively, for 30-day MACE. When combined with troponin below the LOD, sensitivity for AMI was 100% (95% CI, 93%-100%; difference 2%; 95% CI, -2% to 6%) for low-risk HEART Score and 100% (95% CI, 93%-100%; difference 4%; 95% CI, -1.5% to 10%) for ACS Pretest Probability <2%. When combined with troponin below the LOD, sensitivity for 30-day MACE was 100% (95% CI, 95%-100%; difference 6%; 95% CI, 1%-12%) for low-risk HEART Score and 100% (95% CI, 95%-100%; difference 5%; 95% CI, 0.2%-10%) for ACS Pretest Probability <2%. Addition of a single troponin below the LOD to these scores improves sensitivity for 30-day MACE.

  19. Towards evidence-based emergency medicine: Best BETs from the Manchester Royal Infirmary. BET 2: Is there value in testing troponin levels after ICD discharge?

    PubMed

    Targett, Chris; Harris, Tim

    2014-03-01

    A short cut review was carried out to establish whether testing for troponin levels is useful after discharge of an Implanted Cardioverter-Defibrillator (ICD). Many papers were found using the reported searches, none of which directly addressed the problem but some 13 presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that the number of ICD discharges must be taken into account when evaluating any troponin level rise. Overall a positive troponin assay post ICD discharge is independently associated with an increased mortality.

  20. Toward Protein Structure In Situ: Comparison of Two Bifunctional Rhodamine Adducts of Troponin C

    PubMed Central

    Julien, Olivier; Sun, Yin-Biao; Knowles, Andrea C.; Brandmeier, Birgit D.; Dale, Robert E.; Trentham, David R.; Corrie, John E. T.; Sykes, Brian D.; Irving, Malcolm

    2007-01-01

    As part of a program to develop methods for determining protein structure in situ, sTnC was labeled with a bifunctional rhodamine (BR or BSR), cross-linking residues 56 and 63 of its C-helix. NMR spectroscopy of the N-terminal domain of BSR-labeled sTnC in complex with Ca2+ and the troponin I switch peptide (residues 115–131) showed that BSR labeling does not significantly affect the secondary structure of the protein or its dynamics in solution. BR-labeling was previously shown to have no effect on the solution structure of this complex. Isometric force generation in isolated demembranated fibers from rabbit psoas muscle into which BR- or BSR-labeled sTnC had been exchanged showed reduced Ca2+-sensitivity, and this effect was larger with the BSR label. The orientation of rhodamine dipoles with respect to the fiber axis was determined by polarized fluorescence. The mean orientations of the BR and BSR dipoles were almost identical in relaxed muscle, suggesting that both probes accurately report the orientation of the C-helix to which they are attached. The BSR dipole had smaller orientational dispersion, consistent with less flexible linkers between the rhodamine dipole and cysteine-reactive groups. PMID:17483167

  1. ATPase activity and light scattering of acto-heavy meromyosin: dependence on ATP concentration and on ionic strength.

    PubMed

    Dancker, P

    1975-01-01

    1. The dependence on ATP concentration of ATPase activity and light scattering decrease of acto-HMM could be described at very low ionic strength by one hyperbolic adsorption isotherm with a dissociation constant of 3 X 10(-6)M. Hence the increase of ATP ase activity was paralleled by a decrease in light scattering. At higher values of ionic strength ATPase activity stopped rising before HMM was completely saturated with ATP. Higher ionic strength prevented ATPase activity from further increasing when the rigor links (links between actin and nucleotide-free myosin), which have formerly protected the ATPase against the suppressing action of higher ionic strength have fallen below a certain amount. This protecting influence of rigor links did not require tropomyosin-troponin. 2. For complete activation of ATPase activity by actin less actin was needed when HMM was incompletely saturated with ATP than when it was completely saturated with ATP. 3. The apparent affinity of ATP to regulated acto-HMM (which contained tropomyosin-troponin) was lower than to unregulated acto-HMM (which was devoid of tropomyosin-troponin). In the presence of rigor complexes (indicated by an incomplete decrease of light scattering) the ATPase activity of regulated acto-HMM was higher than that of unregulated acto-HMM. At increasing ATP concentrations the ATPase activity of regulated acto-HMM stopped rising at a similar degree of saturation with ATP as the ATPase activity of unregulated acto-HMM at the same ionic strength.

  2. Emergency department triage strategies for acute chest pain using creatine kinase-MB and troponin I assays: a cost-effectiveness analysis.

    PubMed

    Polanczyk, C A; Kuntz, K M; Sacks, D B; Johnson, P A; Lee, T H

    1999-12-21

    Evaluation of acute chest pain is highly variable. To evaluate the cost-effectiveness of strategies using cardiac markers and noninvasive tests for myocardial ischemia. Cost-effectiveness analysis. Prospective data from 1066 patients with chest pain and from the published literature. Patients admitted with acute chest pain. Lifetime. Societal. Creatine kinase (CK)-MB mass assay alone; CK-MB mass assay followed by cardiac troponin I assay if the CK-MB value is normal; CK-MB mass assay followed by troponin I assay if the CK-MB value is normal and electrocardiography shows ischemic changes; both CK-MB mass and troponin I assays; and troponin I assay alone. These strategies were evaluated alone or in combination with early exercise testing. Lifetime cost, life expectancy (in years), and incremental cost-effectiveness. For patients 55 to 64 years of age, measurement of CK-MB mass followed by exercise testing in appropriate patients was the most competitive strategy ($43000 per year of life saved). Measurement of CK-MB mass followed by troponin I measurement had an incremental cost-effectiveness ratio of $47400 per year of life saved for patients 65 to 74 years of age; it was also the most cost-effective strategy when early exercise testing could not be performed, CK-MB values were normal, and ischemic changes were seen on electrocardiography. Results were influenced by age, probability of myocardial infarction, and medical costs. Measurement of CK-MB mass plus early exercise testing is a cost-effective initial strategy for younger patients and those with a low to moderate probability of myocardial infarction. Troponin I measurement can be a cost-effective second test in higher-risk subsets of patients if the CK-MB level is normal and early exercise testing is not an option.

  3. Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.

    PubMed

    Jarolim, Petr; Patel, Purvish P; Conrad, Michael J; Chang, Lei; Melenovsky, Vojtech; Wilson, David H

    2015-10-01

    The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an investigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals. © 2015 American Association for Clinical Chemistry.

  4. Atrial fibrillation associated with exogenous subclinical hyperthyroidism, changing axis deviation, troponin-I positive and without acute coronary syndrome.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2011-08-04

    Changing axis deviation has been rarely reported also during atrial fibrillation or atrial flutter. Changing axis deviation has been also rarely reported during acute myocardial infarction associated with atrial fibrillation or at the end of atrial fibrillation during acute myocardial infarction. Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. It has also been reported that increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. Serum troponin-I is a sensitive indicator of myocardial damage but abnormal troponin-I levels have been also reported without acute coronary syndrome and without cardiac damage. Abnormal troponin-I levels after supraventricular tachycardia have been also reported. We present a case of changing axis deviation in a 49-year-old Italian man with atrial fibrillation, exogenous subclinical hyperthyroidism and troponin-I positive without acute coronary syndrome. Also this case focuses attention on changing axis deviation, on subclinical hyperthyroidism and on the importance of a correct evaluation of abnormal troponin-I levels. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  5. Serum cardiac troponin I and cardiac troponin T concentrations in dogs with gastric dilatation-volvulus.

    PubMed

    Schober, Karsten E; Cornand, Corinna; Kirbach, Babett; Aupperle, Heike; Oechtering, Gerhard

    2002-08-01

    To determine whether serum concentrations of cardiac troponin I (cTnI) and cardiac troponin T (cTnT) are increased in dogs with gastric dilatationvolvulus (GDV) and whether concentrations correlate with severity of ECG abnormalities or outcome. Prospective case series. 85 dogs with GDV. Serum cTnl and cTnT concentrations were measured 12 to 24, 48, 72, and 96 hours after surgery. Dogs were grouped on the basis of severity of ECG abnormalities and outcome. cTnl and cTnT were detected in serum from 74 (87%) and 43 (51%) dogs, respectively. Concentrations were significantly different among groups when dogs were grouped on the basis of severity of ECG abnormalities (none or mild vs moderate vs severe). Dogs that died (n = 16) had significantly higher serum cTnI (24.9 ng/ml) and cTnT (0.18 ng/ml) concentrations than did dogs that survived (2.05 and < 0.01 ng/ml, respectively). Myocardial cell injury was confirmed at necropsy in 4 dogs with high serum cardiac troponin concentrations. Results indicate that concentrations of cTnI and cTnT suggestive of myocardial cell injury can commonly be found in serum from dogs with GDV and that serum cardiac troponin concentrations are associated with severity of ECG abnormalities and outcome.

  6. [Diagnostics of acute myocardial infarction in elderly patients].

    PubMed

    Bahrmann, P; Heppner, H J; Bahrmann, A; Christ, M; Bertsch, T; Sieber, C C

    2011-06-01

    The early diagnosis of an acute myocardial infarction (MI) is improved by the introduction of novel high-sensitivity troponin assays. These assays can measure low level myocardial injury not detectable by standard troponin assays. Especially in older patients who appear to have a higher basal troponin level, the results must always be judged in the context of the medical history, physical examination, electrocardiogram (ECG) and any further findings. Even small increases in high-sensitivity troponin indicate increased risk for death or MI during follow-up. In the case of MI an invasive strategy results in better survival rates compared with conservative therapy but at the expense of an increased risk of bleeding in elderly patients. This article provides an overview on the diagnosis of MI in elderly patients.

  7. Origin of noise in liquid-gated Si nanowire troponin biosensors.

    PubMed

    Kutovyi, Y; Zadorozhnyi, I; Hlukhova, H; Handziuk, V; Petrychuk, M; Ivanchuk, Andriy; Vitusevich, S

    2018-04-27

    Liquid-gated Si nanowire field-effect transistor (FET) biosensors are fabricated using a complementary metal-oxide-semiconductor-compatible top-down approach. The transport and noise properties of the devices reflect the high performance of the FET structures, which allows label-free detection of cardiac troponin I (cTnI) molecules. Moreover, after removing the troponin antigens the structures demonstrate the same characteristics as before cTnI detection, indicating the reusable operation of biosensors. Our results show that the additional noise is related to the troponin molecules and has characteristics which considerably differ from those usually recorded for conventional FETs without target molecules. We describe the origin of the noise and suggest that noise spectroscopy represents a powerful tool for understanding molecular dynamic processes in nanoscale FET-based biosensors.

  8. Origin of noise in liquid-gated Si nanowire troponin biosensors

    NASA Astrophysics Data System (ADS)

    Kutovyi, Y.; Zadorozhnyi, I.; Hlukhova, H.; Handziuk, V.; Petrychuk, M.; Ivanchuk, Andriy; Vitusevich, S.

    2018-04-01

    Liquid-gated Si nanowire field-effect transistor (FET) biosensors are fabricated using a complementary metal-oxide-semiconductor-compatible top-down approach. The transport and noise properties of the devices reflect the high performance of the FET structures, which allows label-free detection of cardiac troponin I (cTnI) molecules. Moreover, after removing the troponin antigens the structures demonstrate the same characteristics as before cTnI detection, indicating the reusable operation of biosensors. Our results show that the additional noise is related to the troponin molecules and has characteristics which considerably differ from those usually recorded for conventional FETs without target molecules. We describe the origin of the noise and suggest that noise spectroscopy represents a powerful tool for understanding molecular dynamic processes in nanoscale FET-based biosensors.

  9. Elevated Cardiac Troponin T in Patients With Skeletal Myopathies.

    PubMed

    Schmid, Johannes; Liesinger, Laura; Birner-Gruenberger, Ruth; Stojakovic, Tatjana; Scharnagl, Hubert; Dieplinger, Benjamin; Asslaber, Martin; Radl, Roman; Beer, Meinrad; Polacin, Malgorzata; Mair, Johannes; Szolar, Dieter; Berghold, Andrea; Quasthoff, Stefan; Binder, Josepha S; Rainer, Peter P

    2018-04-10

    Cardiac troponins are often elevated in patients with skeletal muscle disease who have no evidence of cardiac disease. The goal of this study was to characterize cardiac troponin concentrations in patients with myopathies and derive insights regarding the source of elevated troponin T measurements. Cardiac troponin T (cTnT) and cardiac troponin I (cTnI) concentrations were determined by using high sensitivity assays in 74 patients with hereditary and acquired skeletal myopathies. Patients underwent comprehensive cardiac evaluation, including 12-lead electrocardiogram, 24-h electrocardiogram, cardiac magnetic resonance imaging, and coronary artery computed tomography. cTnT and cTnI protein expression was determined in skeletal muscle samples of 9 patients and in control tissues derived from autopsy using antibodies that are used in commercial assays. Relevant Western blot bands were subjected to liquid chromatography tandem mass spectrometry for protein identification. Levels of cTnT (median: 24 ng/l; interquartile range: 11 to 54 ng/l) were elevated (>14 ng/l) in 68.9% of patients; cTnI was elevated (>26 ng/l) in 4.1% of patients. Serum cTnT levels significantly correlated with creatine kinase and myoglobin (r = 0.679 and 0.786, respectively; both p < 0.001). Based on cTnT serial testing, 30.1% would have fulfilled current rule-in criteria for myocardial infarction. Noncoronary cardiac disease was present in 23%. Using cTnT antibodies, positive bands were found in both diseased and healthy skeletal muscle at molecular weights approximately 5 kDa below cTnT. Liquid chromatography tandem mass spectrometry identified the presence of skeletal troponin T isoforms in these bands. Measured cTnT concentrations were chronically elevated in the majority of patients with skeletal myopathies, whereas cTnI elevation was rare. Our data indicate that cross-reaction of the cTnT immunoassay with skeletal muscle troponin isoforms was the likely cause. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Effect of antioxidant supplementation on exercise-induced cardiac troponin release in cyclists: a randomized trial.

    PubMed

    Klinkenberg, Lieke J J; Res, Peter T; Haenen, Guido R; Bast, Aalt; van Loon, Luc J C; van Dieijen-Visser, Marja P; Meex, Steven J R

    2013-01-01

    Cardiac troponin is the biochemical gold standard to diagnose acute myocardial infarction. Interestingly however, elevated cardiac troponin concentrations are also frequently observed during and after endurance-type exercise. Oxidative stress associated with prolonged exercise has been proposed to contribute to cardiac troponin release. Therefore, the aim of this study was to assess the effect of 4 week astaxanthin supplementation (a potent cartenoid antioxidant) on antioxidant capacity and exercise-induced cardiac troponin release in cyclists. Thirty-two well-trained male cyclists (age 25±5, weight 73±7 kg, maximum O2 uptake 60±5 mL·kg(-1)·min(-1), Wmax 5.4±0.5 W·kg(-1); mean ± SD) were repeatedly subjected to a laboratory based standardized exercise protocol before and after 4 weeks of astaxanthin (20 mg/day), or placebo supplementation in a double-blind randomized manner. Blood samples were obtained at baseline, at 60 min of cycling and immediately post-exercise (≈ 120 min). The pre-supplementation cycling trial induced a significant rise of median cardiac troponin T concentrations from 3.2 (IQR 3.0-4.2) to 4.7 ng/L (IQR 3.7-6.7), immediately post-exercise (p<0.001). Four weeks of astaxanthin supplementation significantly increased mean basal plasma astaxanthin concentrations from non-detectable values to 175±86 µg·kg(-1). However, daily astaxanthin supplementation had no effect on exercise-induced cardiac troponin T release (p = 0.24), as measured by the incremental area under the curve. Furthermore, the elevation in basal plasma astaxanthin concentrations was not reflected in changes in antioxidant capacity markers (trolox equivalent antioxidant capacity, uric acid, and malondialdehyde). Markers of inflammation (high-sensitivity C-reactive protein) and exercise-induced skeletal muscle damage (creatine kinase) were equally unaffected by astaxanthin supplementation. Despite substantial increases in plasma astaxanthin concentrations, astaxanthin supplementation did not improve antioxidant capacity in well-trained cyclists. Accordingly, exercise-induced cardiac troponin T concentrations were not affected by astaxanthin supplementation. ClinicalTrials.gov NCT01241877.

  11. Effect of Xenon Anesthesia Compared to Sevoflurane and Total Intravenous Anesthesia for Coronary Artery Bypass Graft Surgery on Postoperative Cardiac Troponin Release: An International, Multicenter, Phase 3, Single-blinded, Randomized Noninferiority Trial.

    PubMed

    Hofland, Jan; Ouattara, Alexandre; Fellahi, Jean-Luc; Gruenewald, Matthias; Hazebroucq, Jean; Ecoffey, Claude; Joseph, Pierre; Heringlake, Matthias; Steib, Annick; Coburn, Mark; Amour, Julien; Rozec, Bertrand; Liefde, Inge de; Meybohm, Patrick; Preckel, Benedikt; Hanouz, Jean-Luc; Tritapepe, Luigi; Tonner, Peter; Benhaoua, Hamina; Roesner, Jan Patrick; Bein, Berthold; Hanouz, Luc; Tenbrinck, Rob; Bogers, Ad J J C; Mik, Bert G; Coiffic, Alain; Renner, Jochen; Steinfath, Markus; Francksen, Helga; Broch, Ole; Haneya, Assad; Schaller, Manuella; Guinet, Patrick; Daviet, Lauren; Brianchon, Corinne; Rosier, Sebastien; Lehot, Jean-Jacques; Paarmann, Hauke; Schön, Julika; Hanke, Thorsten; Ettel, Joachym; Olsson, Silke; Klotz, Stefan; Samet, Amir; Laurinenas, Giedrius; Thibaud, Adrien; Cristinar, Mircea; Collanges, Olivier; Levy, François; Rossaint, Rolf; Stevanovic, Ana; Schaelte, Gereon; Stoppe, Christian; Hamou, Nora Ait; Hariri, Sarah; Quessard, Astrid; Carillion, Aude; Morin, Hélène; Silleran, Jacqueline; Robert, David; Crouzet, Anne-Sophie; Zacharowski, Kai; Reyher, Christian; Iken, Sonja; Weber, Nina C; Hollmann, Marcus; Eberl, Susanne; Carriero, Giovanni; Collacchi, Daria; Di Persio, Alessandra; Fourcade, Olivier; Bergt, Stefan; Alms, Angela

    2017-12-01

    Ischemic myocardial damage accompanying coronary artery bypass graft surgery remains a clinical challenge. We investigated whether xenon anesthesia could limit myocardial damage in coronary artery bypass graft surgery patients, as has been reported for animal ischemia models. In 17 university hospitals in France, Germany, Italy, and The Netherlands, low-risk elective, on-pump coronary artery bypass graft surgery patients were randomized to receive xenon, sevoflurane, or propofol-based total intravenous anesthesia for anesthesia maintenance. The primary outcome was the cardiac troponin I concentration in the blood 24 h postsurgery. The noninferiority margin for the mean difference in cardiac troponin I release between the xenon and sevoflurane groups was less than 0.15 ng/ml. Secondary outcomes were the safety and feasibility of xenon anesthesia. The first patient included at each center received xenon anesthesia for practical reasons. For all other patients, anesthesia maintenance was randomized (intention-to-treat: n = 492; per-protocol/without major protocol deviation: n = 446). Median 24-h postoperative cardiac troponin I concentrations (ng/ml [interquartile range]) were 1.14 [0.76 to 2.10] with xenon, 1.30 [0.78 to 2.67] with sevoflurane, and 1.48 [0.94 to 2.78] with total intravenous anesthesia [per-protocol]). The mean difference in cardiac troponin I release between xenon and sevoflurane was -0.09 ng/ml (95% CI, -0.30 to 0.11; per-protocol: P = 0.02). Postoperative cardiac troponin I release was significantly less with xenon than with total intravenous anesthesia (intention-to-treat: P = 0.05; per-protocol: P = 0.02). Perioperative variables and postoperative outcomes were comparable across all groups, with no safety concerns. In postoperative cardiac troponin I release, xenon was noninferior to sevoflurane in low-risk, on-pump coronary artery bypass graft surgery patients. Only with xenon was cardiac troponin I release less than with total intravenous anesthesia. Xenon anesthesia appeared safe and feasible.

  12. Structural Basis for the Regulation of Muscle Contraction by Troponin and Tropomyosin

    PubMed Central

    Galińska-Rakoczy, Agnieszka; Engel, Patti; Xu, Chen; Jung, HyunSuk; Craig, Roger; Tobacman, Larry S.; Lehman, William

    2008-01-01

    The molecular switching mechanism governing skeletal and cardiac muscle contraction couples the binding of Ca2+ on troponin to the movement of tropomyosin on actin filaments. Despite years of investigation, this mechanism remains unclear because it has not yet been possible to directly assess the structural influence of troponin on tropomyosin that causes actin filaments, and hence myosin-crossbridge cycling and contraction, to switch on and off. A C-terminal domain of troponin I is thought to be intimately involved in inducing tropomyosin movement to an inhibitory position that blocks myosin-crossbridge interaction. Release of this regulatory, latching domain from actin after Ca2+-binding to TnC presumably allows tropomyosin movement away from the inhibitory position on actin, thus initiating contraction. However, the structural interactions of the regulatory domain of TnI with tropomyosin and actin that cause tropomyosin movement are unknown and thus the regulatory process is not well defined. Here, thin filaments were labeled with an engineered construct representing C-terminal TnI and then 3D-EM was used to resolve where troponin is anchored on actin-tropomyosin. EM-reconstruction showed how TnI-binding to both actin and tropomyosin at low-Ca2+ competes with tropomyosin for a common site on actin and drives tropomyosin movement to a constrained, relaxing position to inhibit myosin-crossbridge association. Thus the observations reported reveal the structural mechanism responsible for troponin-tropomyosin-mediated steric-interference of actin-myosin interaction that regulates muscle contraction. PMID:18514658

  13. Troponin I degradation in serum of patients with acute ischemic stroke.

    PubMed

    Jensen, Jesper K; Hallén, Jonas; Lund, Terje; Madsen, Lene Helleskov; Grieg, Zanina; Januzzi, James L; Atar, Dan

    2011-02-01

    Although troponin is a cornerstone biomarker in the assessment and management of patients with acute coronary syndrome, much remains to be learned about the biology of this widely used biomarker, including its post-release modification. Degradation of troponin following release in patients with acute coronary syndrome has been described; however whether such post-release modification occurs in other non-acute coronary syndrome states remains unknown. The aim of this study was to define troponin degradation in patients with acute ischemic stroke. Troponin I (cTnI) was measured daily during the first 5 days of admission in 244 patients with acute ischemic stroke. Western blot analysis was performed using anti-cTnI antibodies and compared with serum concentrations of cTnI in seven patients and one patient with myocardial infarction (positive control). Elevated levels of troponin were detected in 25 (10%) patients; in all, both intact cTnI and cTnI degradation products were detected, with up to seven degradation fragments found. Samples with the highest total cTnI levels gave the strongest and most numerous western-blotting bands. All fragments were comparable with the degradation pattern of the positive control in terms of position. Immunoblotting of blood samples from patients with acute ischemic stroke reveals similar degradation patterns of cTnI as has been described in patients with acute myocardial infarction. The biological ramification and potential clinical impact of this finding bears further scrutiny.

  14. Loss of Prox1 in striated muscle causes slow to fast skeletal muscle fiber conversion and dilated cardiomyopathy.

    PubMed

    Petchey, Louisa K; Risebro, Catherine A; Vieira, Joaquim M; Roberts, Tom; Bryson, John B; Greensmith, Linda; Lythgoe, Mark F; Riley, Paul R

    2014-07-01

    Correct regulation of troponin and myosin contractile protein gene isoforms is a critical determinant of cardiac and skeletal striated muscle development and function, with misexpression frequently associated with impaired contractility or disease. Here we reveal a novel requirement for Prospero-related homeobox factor 1 (Prox1) during mouse heart development in the direct transcriptional repression of the fast-twitch skeletal muscle genes troponin T3, troponin I2, and myosin light chain 1. A proportion of cardiac-specific Prox1 knockout mice survive beyond birth with hearts characterized by marked overexpression of fast-twitch genes and postnatal development of a fatal dilated cardiomyopathy. Through conditional knockout of Prox1 from skeletal muscle, we demonstrate a conserved requirement for Prox1 in the repression of troponin T3, troponin I2, and myosin light chain 1 between cardiac and slow-twitch skeletal muscle and establish Prox1 ablation as sufficient to cause a switch from a slow- to fast-twitch muscle phenotype. Our study identifies conserved roles for Prox1 between cardiac and skeletal muscle, specifically implicated in slow-twitch fiber-type specification, function, and cardiomyopathic disease.

  15. Loss of Prox1 in striated muscle causes slow to fast skeletal muscle fiber conversion and dilated cardiomyopathy

    PubMed Central

    Petchey, Louisa K.; Risebro, Catherine A.; Vieira, Joaquim M.; Roberts, Tom; Bryson, John B.; Greensmith, Linda; Lythgoe, Mark F.; Riley, Paul R.

    2014-01-01

    Correct regulation of troponin and myosin contractile protein gene isoforms is a critical determinant of cardiac and skeletal striated muscle development and function, with misexpression frequently associated with impaired contractility or disease. Here we reveal a novel requirement for Prospero-related homeobox factor 1 (Prox1) during mouse heart development in the direct transcriptional repression of the fast-twitch skeletal muscle genes troponin T3, troponin I2, and myosin light chain 1. A proportion of cardiac-specific Prox1 knockout mice survive beyond birth with hearts characterized by marked overexpression of fast-twitch genes and postnatal development of a fatal dilated cardiomyopathy. Through conditional knockout of Prox1 from skeletal muscle, we demonstrate a conserved requirement for Prox1 in the repression of troponin T3, troponin I2, and myosin light chain 1 between cardiac and slow-twitch skeletal muscle and establish Prox1 ablation as sufficient to cause a switch from a slow- to fast-twitch muscle phenotype. Our study identifies conserved roles for Prox1 between cardiac and skeletal muscle, specifically implicated in slow-twitch fiber-type specification, function, and cardiomyopathic disease. PMID:24938781

  16. [Should the patient with myocardial bridge be advised not to performe extreme sport effort? Case of a patient with troponin I elevation after exercise].

    PubMed

    Jankowski, Krzysztof; Ożdżeńska-Milke, Ewa; Jankowski, Łukasz; Rzewuska, Ewa; Dul, Przemysław; Ilnicka, Edyta; Kobylecka, Małgorzata; Pruszczyk, Piotr

    2012-01-01

    Elevated levels of cardiac troponins are an established method of diagnosis of heart muscle necrosis. A case of a long distance amateur-marathon runner, who showed significant elevation of plasma troponin I after extreme physical effort is reported. The diagnostic examinations did not reveal atherosclerosis burden, but myocardial bridging of coronary artery. The authors describe the significance of the pathology in the view of extreme sport effort performed by the described patient.

  17. Field-Effect Transistor-Integration with TiO2 Nanoparticles for Sensing of Cardiac Troponin I Biomarker.

    PubMed

    Arshad, M K Md; Adzhri, R; Fathil, M F M; Gopinath, Subash C B; N M, Nuzaihan M

    2018-08-01

    The development of electrical biosensor towards device miniaturization in order to achieve better sensitivity with enhanced electrical signal has certain limitations especially complexity in fabrication process and costs. In this paper, an alternative technique with minor modification in the device structure is presented for signal amplification by implementing ambipolar conduction in the biosensor itself. We demonstrated the field-effect transistor (FET)-based biosensor coupled back-gate for attaining a higher sensitivity with the detection of lower target abundance. To utilize the coupled back-gate as a pre-amplifier, silicon-on-insulator wafer with thicknesses of top-silicon and buried oxide (BOX) layers of 70 nm and 145 nm, respectively were desired. Titanium dioxide (TiO2) nanomaterial was deposited using sol-gel method on the channel which acts as a transducer. Surface functionalization on TiO2 thin film allowed an effective immobilization of anti-cardiac troponin I antibody to interact cardiac troponin I (cTnI). Binding events at each step was validated by X-ray photoelectron spectroscopy (XPS) analysis. Further, electrical characterization (Id-Vd) confirms the potentiality of FET-based biosensor to detect cTnI (represents acute myocardial infarction disease) with the concentration ranges from 10 μg/ml down to 1 fg/ml. The sensitivity of 459.2 nA (g/ml)-1 and lower detection limit of 1 fg/ml were achieved at Vbg = -5 V and Vd = 5 V. The designed device demonstrates its ability to detect lower level of cTnI with pre-amplified electrical signal by back-gate biasing.

  18. Comparison of QTc and Troponin Levels in ST Elevation MIs Compared with Non-ST Elevation MIs.

    PubMed

    Henrie, Nathan; Harvell, Bryan; Ernst, Amy A; Weiss, Steven J; Oglesbee, Scott; Sarangarm, Dusadee; Hernandez, Lorenzo

    2017-03-01

    ST elevation myocardial infarctions (STEMIs) and non-ST elevation myocardial infarctions (NSTEMIs) have differences that can be important to differentiate. Our primary hypothesis was that corrected QT (QTc) duration and troponin I levels were higher in STEMIs compared with NSTEMIs. The objective of our study was to compare STEMIs with NSTEMIs for QTc duration and troponin levels. This was a retrospective case-control study of all STEMIs and a random sample of NSTEMIs during a 1-year period. STEMIs were retrieved by searching our electrocardiogram database for all of the cardiology-diagnosed STEMIs. NSTEMIs were found by selecting a randomized sample of all of the patients with a final discharge diagnosis of NSTEMI. Records and electrocardiograms were reviewed for initial troponin I levels and QTc duration. Data extractors were educated formally and a 5% sample was reevaluated by the other extractor as a reliability measure. Data analysis included χ 2 tests and parametric or nonparametric analysis, where appropriate. A logistic regression model was created with variables selected a priori for predictors of STEMIs compared with NSTEMIs. A total of 92 STEMIs and 111 NSTEMIs were evaluated, and interrater reliability showed 90% agreement. Patients with NSTEMIs had significantly longer QTc. Troponin I did not differ on univariate analysis. In a logistic model, Hispanics were more likely than whites to have a STEMI (adjusted odds ratio [AOR] 2.2, 95% confidence interval [CI] 1.09-4.5). An increase in troponin I of 1 was associated with a 7% increase in the AOR of a STEMI (AOR 1.7, 95% CI 1.03-1.12) and an increase in QTc by 10 was associated with a 13% decrease in the AOR of a STEMI (AOR 0.87, 95% CI 0.78-0.93). Patients with NSTEMIs had longer QTc intervals and lower troponin I levels than those with STEMIs.

  19. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  20. Diagnostic Utility of High Sensitivity Troponins for Echocardiographic Markers of Structural Heart Disease.

    PubMed

    Wang, Tom Kai Ming; Dugo, Clementina; Gillian, Yvonne; Yvonne, Wynne; Heather, Semple; Kevin, Smith; Peter, Cleave; Jonathan, Christiansen; Andrew, To; Nezar, Amir; Scott, Tony; Ross, Boswell; Patrick, Gladding

    2018-02-15

    The conventional use of high-sensitivity troponins (hs-troponins) is for diagnosing myocardial infarction however they also have a role in chronic disease management. This pilot study assessed the relationship of hs-troponins with echocardiographic markers of left ventricular hypertrophy (LVH) and structural heart disease (SHD). Patients undergoing computer gomography (CT) coronary angiogram for low-intermediate risk chest pain and healthy volunteers were recruited. Hs-troponins Singulex I, Abbott I and Roche T and N-terminal pro-brain natriuretic peptide (NT-proBNP) were evaluated in relation to SHD parameters including left ventricular hypertrophy (LVH Echo ) and left atrial enlargement (LAE Echo ) on echocardiography. 78 subjects who underwent echocardiography were included in this study. C-statistics (95% confidence interval) of the four biomarkers for predicting LVH Echo were 0.84 (0.72-0.92), 0.84 (0.73-0.92), 0.75 (0.63-0.85) and 0.62 (0.49-0.74); for LAE Echo 0.74 (0.6-0.85), 0.78 (0.66-0.88), 0.55 (0.42-0.67) and 0.68 (0.62-0.85); and composite SHD 0.79 (0.66-0.88), 0.87 (0.75-0.94), 0.62 (0.49-0.73) and 0.74 (0.62-0.84) respectively. Optimal cut points for SHD were >1.2 ng/L, >1.6 ng/L, >8 ng/L and >18 pmol/L respectively. These results advocate the potential role of hs-troponins as screening tools for structural heart disease with theranostic implications.

  1. Epitope mapping and targeted quantitation of the cardiac biomarker troponin by SID-MRM mass spectrometry.

    PubMed

    Zhao, Cheng; Trudeau, Beth; Xie, Helen; Prostko, John; Fishpaugh, Jeffrey; Ramsay, Carol

    2014-06-01

    The absolute quantitation of the targeted protein using MS provides a promising method to evaluate/verify biomarkers used in clinical diagnostics. In this study, a cardiac biomarker, troponin I (TnI), was used as a model protein for method development. The epitope peptide of TnI was characterized by epitope excision followed with LC/MS/MS method and acted as the surrogate peptide for the targeted protein quantitation. The MRM-based MS assay using a stable internal standard that improved the selectivity, specificity, and sensitivity of the protein quantitation. Also, plasma albumin depletion and affinity enrichment of TnI by anti-TnI mAb-coated microparticles reduced the sample complexity, enhanced the dynamic range, and further improved the detecting sensitivity of the targeted protein in the biological matrix. Therefore, quantitation of TnI, a low abundant protein in human plasma, has demonstrated the applicability of the targeted protein quantitation strategy through its epitope peptide determined by epitope mapping method. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study.

    PubMed

    Shah, Anoop S V; Anand, Atul; Sandoval, Yader; Lee, Kuan Ken; Smith, Stephen W; Adamson, Philip D; Chapman, Andrew R; Langdon, Timothy; Sandeman, Dennis; Vaswani, Amar; Strachan, Fiona E; Ferry, Amy; Stirzaker, Alexandra G; Reid, Alan; Gray, Alasdair J; Collinson, Paul O; McAllister, David A; Apple, Fred S; Newby, David E; Mills, Nicholas L

    2015-12-19

    Suspected acute coronary syndrome is the commonest reason for emergency admission to hospital and is a large burden on health-care resources. Strategies to identify low-risk patients suitable for immediate discharge would have major benefits. We did a prospective cohort study of 6304 consecutively enrolled patients with suspected acute coronary syndrome presenting to four secondary and tertiary care hospitals in Scotland. We measured plasma troponin concentrations at presentation using a high-sensitivity cardiac troponin I assay. In derivation and validation cohorts, we evaluated the negative predictive value of a range of troponin concentrations for the primary outcome of index myocardial infarction, or subsequent myocardial infarction or cardiac death at 30 days. This trial is registered with ClinicalTrials.gov (number NCT01852123). 782 (16%) of 4870 patients in the derivation cohort had index myocardial infarction, with a further 32 (1%) re-presenting with myocardial infarction and 75 (2%) cardiac deaths at 30 days. In patients without myocardial infarction at presentation, troponin concentrations were less than 5 ng/L in 2311 (61%) of 3799 patients, with a negative predictive value of 99·6% (95% CI 99·3-99·8) for the primary outcome. The negative predictive value was consistent across groups stratified by age, sex, risk factors, and previous cardiovascular disease. In two independent validation cohorts, troponin concentrations were less than 5 ng/L in 594 (56%) of 1061 patients, with an overall negative predictive value of 99·4% (98·8-99·9). At 1 year, these patients had a lower risk of myocardial infarction and cardiac death than did those with a troponin concentration of 5 ng/L or more (0·6% vs 3·3%; adjusted hazard ratio 0·41, 95% CI 0·21-0·80; p<0·0001). Low plasma troponin concentrations identify two-thirds of patients at very low risk of cardiac events who could be discharged from hospital. Implementation of this approach could substantially reduce hospital admissions and have major benefits for both patients and health-care providers. British Heart Foundation and Chief Scientist Office (Scotland). Copyright © 2015 Shah et al. Open Access article distributed under the terms of CC BY-NC-ND. Published by Elsevier Ltd.. All rights reserved.

  3. Right ventricular dysfunction in acute pulmonary embolism: NT-proBNP vs. troponin T.

    PubMed

    Cotugno, Marilena; Orgaz-Molina, Jacinto; Rosa-Salazar, Vladimir; Guirado-Torrecillas, Leticia; García-Pérez, Bartolomé

    2017-04-21

    Dysfunction of the right ventricle (RV) is a parameter of severity in acute pulmonary embolism (PE). Echocardiographic assessment is not always possible in accident and emergency, hence the need to predict the presence of RV dysfunction using easily measurable parameters. To analyse the value of NT-proBNP and troponin T as markers of RV dysfunction in patients with acute PE. Secondarily, to assess the relationship between RV failure and clinical parameters related to PE. Analytical, observational, cross-sectional and retrospective study comparing the values NT-proBNP, troponin T and presenting symptoms of PE among patients with and without RV dysfunction. One hundred seventy-two patients (52 with RV failure,120 without) were included. All symptoms occurred with similar frequency between the 2groups except dyspnea and syncope (more common in the group with RV failure). Both NT-proBNP and troponin T had significantly higher values in the group of patients with RV dysfunction. However, in the multivariate analysis, NT-proBNP had a higher explanatory value for RV failure than troponin T. NT-proBNP is a diagnostic parameter of RV dysfunction with higher sensitivity in the context of acute PE. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  4. Clinical Characteristics, Management, and Outcomes of Suspected Poststroke Acute Coronary Syndrome

    PubMed Central

    De Venecia, Toni Anne; Wongrakpanich, Supakanya; Rodriguez-Ziccardi, Mary; Yadlapati, Sujani; Kishlyansky, Marina; Rammohan, Harish Seetha; Figueredo, Vincent M.

    2017-01-01

    Background Acute coronary syndrome (ACS) can complicate acute ischemic stroke, causing significant morbidity and mortality. To date, literatures that describe poststroke acute coronary syndrome and its morbidity and mortality burden are lacking. Methods This is a single center, retrospective study where clinical characteristics, cardiac evaluation, and management of patients with suspected poststroke ACS were compared and analyzed for their association with inpatient mortality and 1-year all-cause mortality. Results Of the 82 patients, 32% had chest pain and 88% had ischemic ECG changes; mean peak troponin level was 18, and mean ejection fraction was 40%. The medical management group had older individuals (73 versus 67 years, p < 0.05), lower mean peak troponin levels (12 versus 49, p < 0.05), and lower mean length of stay (12 versus 25 days, p < 0.05) compared to those who underwent stent or CABG. Troponin levels were significantly associated with 1-year all-cause mortality. Conclusion Age and troponin level appear to play a role in the current clinical decision making for patient with suspected poststroke ACS. Troponin level appears to significantly correlate with 1-year all-cause mortality. In the management of poststroke acute coronary syndrome, optimal medical therapy had similar inpatient and all-cause mortality compared to PCI and/or CABG. PMID:29130017

  5. Selection of DNA aptamers against Human Cardiac Troponin I for colorimetric sensor based dot blot application.

    PubMed

    Dorraj, Ghamar Soltan; Rassaee, Mohammad Javad; Latifi, Ali Mohammad; Pishgoo, Bahram; Tavallaei, Mahmood

    2015-08-20

    Troponin T and I are ideal markers which are highly sensitive and specific for myocardial injury and have shown better efficacy than earlier markers. Since aptamers are ssDNA or RNA that bind to a wide variety of target molecules, the purpose of this research was to select an aptamer from a 79bp single-stranded DNA (ssDNA) random library that was used to bind the Human Cardiac Troponin I from a synthetic nucleic acids library by systematic evolution of ligands exponential enrichment (Selex) based on several selection and amplification steps. Human Cardiac Troponin I protein was coated onto the surface of streptavidin magnetic beads to extract specific aptamer from a large and diverse random ssDNA initial oligonucleotide library. As a result, several aptamers were selected and further examined for binding affinity and specificity. Finally TnIApt 23 showed beast affinity in nanomolar range (2.69nM) toward the target protein. A simple and rapid colorimetric detection assay for Human Cardiac Troponin I using the novel and specific aptamer-AuNPs conjugates based on dot blot assay was developed. The detection limit for this protein using aptamer-AuNPs-based assay was found to be 5ng/ml. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Myocardial protection with prophylactic oral metoprolol during coronary artery bypass grafting surgery: evaluation by troponin I

    PubMed Central

    Rossi Neto, João Manoel; Gun, Carlos; Ramos, Rui Fernando; de Almeida, Antonio Flavio Sanchez; Issa, Mario; Amato, Vivian Lener; Dinkhuysen, Jarbas J.; Piegas, Leopoldo Soares

    2013-01-01

    Introduction Biochemical markers of myocardial injury are frequently altered after cardiac surgery. So far there is no evidence whether oral beta-blockers may reduce myocardial injury after coronary artery bypass grafting. Objective To determine if oral administration of prophylactic metoprolol reduces the release of cardiac troponin I in isolated coronary artery bypass grafting, not complicated by new Q waves. Methods A prospective randomized study, including 68 patients, divided in 2 groups: Group A (n=33, control) and B (n=35, beta-blockers). In group B, metoprolol tartrate was administered 200 mg/day. The myocardial injury was assessed by troponin I with 1 hour and 12 hours after coronary artery bypass grafting. Results No significant difference between groups regarding pre-surgical, surgical, complication in intensive care (15% versus 14%, P=0.92) and the total number of hospital events (21% versus 14%, P=0.45) was observed. The median value of troponin I with 12 hours in the study population was 3.3 ng/ml and was lower in group B than in group A (2.5 ng/ml versus 3.7 ng/ml, P<0,05). In the multivariate analysis, the variables that have shown to be independent predictors of troponin I release after 12 hours were: no beta-blockers administration and number of vessels treated. Conclusion The results of this study in uncomplicated coronary artery bypass grafting, comparing the postoperative release of troponin I at 12 hours between the control group and who used oral prophylactic metoprolol for at least 72 hours, allow to conclude that there was less myocardial injury in the betablocker group, giving some degree of myocardial protection. PMID:24598948

  7. Influence of population selection on the 99th percentile reference value for cardiac troponin assays.

    PubMed

    Collinson, Paul O; Heung, Yen Ming; Gaze, David; Boa, Frances; Senior, Roxy; Christenson, Robert; Apple, Fred S

    2012-01-01

    We sought to determine the effect of patient selection on the 99th reference percentile of 2 sensitive and 1 high-sensitivity (hs) cardiac troponin assays in a well-defined reference population. Individuals>45 years old were randomly selected from 7 representative local community practices. Detailed information regarding the participants was collected via questionnaires. The healthy reference population was defined as individuals who had no history of vascular disease, hypertension, or heavy alcohol intake; were not receiving cardiac medication; and had blood pressure<140/90 mmHg, fasting blood glucose<110 mg/dL (approximately 6 mmol/L), estimated creatinine clearance>60 mL·min(-1)·(1.73 m2)(-1), and normal cardiac function according to results of echocardiography. Samples were stored at -70 °C until analysis for cardiac troponin I (cTnI) and cardiac troponin T (cTnT) and N-terminal pro-B-type natriuretic peptide. Application of progressively more stringent population selection strategies to the initial baseline population of 545 participants until the only individuals who remained were completely healthy according to the study criteria reduced the number of outliers seen and led to a progressive decrease in the 99th-percentile value obtained for the Roche hs-cTnT assay and the sensitive Beckman cTnI assay but not for the sensitive Siemens Ultra cTnI assay. Furthermore, a sex difference found in the baseline population for the hs-cTnT (P=0.0018) and Beckman cTnI assays (P<0.0001) progressively decreased with more stringent population selection criteria. The reference population selection strategy significantly influenced the 99th percentile reference values determined for troponin assays and the observed sex differences in troponin concentrations.

  8. Diagnosis of unstable angina pectoris has declined markedly with the advent of more sensitive troponin assays.

    PubMed

    D'Souza, Maria; Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S; Gerke, Oke; Larsen, Torben B; Diederichsen, Axel C P; Jangaard, Nikolaj; Diederichsen, Søren Z; Hosbond, Susanne; Hove, Jens; Thygesen, Kristian; Mickley, Hans

    2015-08-01

    Since the arrival of the universal definition of myocardial infarction more sensitive troponin assays have been developed. How these occurrences have influenced the proportions and clinical features of the components of acute coronary syndrome have not been studied prospectively in unselected hospital patients. During 2010 we evaluated all patients in whom cardiac troponin I had been measured at a single university hospital. The diagnosis of acute myocardial infarction (ST-elevation myocardial infarction [STEMI] or non-ST-elevation myocardial infarction [NSTEMI]) was established in cases of a rise and/or fall of cardiac troponin I together with cardiac ischemic features. Patients with unstable chest discomfort and cardiac troponin I values below the decision limit of myocardial infarction were diagnosed as having unstable angina pectoris. The definition of acute coronary syndrome included unstable angina pectoris, NSTEMI, and STEMI. Mortality data were obtained from the Danish Civil Personal Registration System. Of 3762 consecutive patients, 516 had acute coronary syndrome. Unstable angina pectoris was present in 7%, NSTEMI in 67%, and STEMI in 26%. The NSTEMI patients were older, more frequently women, and had more comorbidities than patients with unstable angina pectoris and STEMI. At median follow-up of 3.2 years 195 patients had died: 14% of unstable angina pectoris, 45% of NSTEMI, and 25% of STEMI patients. Age-adjusted log-rank statistics revealed differences in mortality: NSTEMI vs unstable angina pectoris (P = .0091) and NSTEMI vs STEMI (P = .0045). The application of the universal definition together with the use of a contemporary troponin assay seems to have reduced the proportion of patients with unstable angina pectoris to the benefit of patients with NSTEMI. Despite this, NSTEMI patients have a sustained higher mortality than patients with STEMI. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: first experience in an emergency department of a general hospital.

    PubMed

    Lotze, Ulrich; Lemm, Holger; Heyer, Anke; Müller, Karin

    2011-01-01

    The purpose of this observational study was to test the diagnostic performance of the Elecsys® troponin T high-sensitive system combined with copeptin measurement for early exclusion of acute myocardial infarction (MI) in clinical practice. Troponin T high-sensitive (diagnostic cutoff: <14 pg/mL) and copeptin (diagnostic cutoff: <14 pmol/L) levels were determined at admission in addition to other routine laboratory parameters in patients with suspected acute MI presenting to the emergency department of a general hospital over a period of five months. Data from 142 consecutive patients (mean age 71.2 ± 13.5 years, 76 men) were analyzed. Final diagnoses were acute MI in 13 patients (nine ST elevation MI, four non-ST elevation MI, 9.2%) unstable angina pectoris in three (2.1%), cardiac symptoms not primarily associated with myocardial ischemia in 79 (55.6%), and noncardiac disease in 47 patients (33.1%). The patients with acute MI were younger and had higher troponin T high-sensitive and copeptin values than patients without acute MI. Seventeen patients had very high copeptin values (>150 pmol/L), one of whom had a level of >700 pmol/L and died of pulmonary embolism. A troponin T high-sensitive level of <14 pg/mL in combination with copeptin <14 pmol/L at initial presentation ruled out acute MI in 45 of the 142 patients (31.7%), each with a sensitivity and negative predictive value of 100%. According to this early experience, a single determination of troponin T high-sensitive and copeptin may enable early and accurate exclusion of acute MI in one third of patients, even in an emergency department of a general hospital.

  10. Elevated troponin predicts long-term adverse cardiovascular outcomes in hypertensive crisis: a retrospective study.

    PubMed

    Pattanshetty, Deepak J; Bhat, Pradeep K; Aneja, Ashish; Pillai, Dilip P

    2012-12-01

    Hypertensive crisis is associated with poor clinical outcomes. Elevated troponin, frequently observed in hypertensive crisis, may be attributed to myocardial supply-demand mismatch or obstructive coronary artery disease (CAD). However, in patients presenting with hypertensive crisis and an elevated troponin, the prevalence of CAD and the long-term adverse cardiovascular outcomes are unknown. We sought to assess the impact of elevated troponin on cardiovascular outcomes and evaluate the role of troponin as a predictor of obstructive CAD in patients with hypertensive crisis. Patients who presented with hypertensive crisis (n = 236) were screened retrospectively. Baseline and follow-up data including the event rates were obtained using electronic patient records. Those without an assay for cardiac Troponin I (cTnI) (n = 65) were excluded. Of the remaining 171 patients, those with elevated cTnI (cTnI ≥ 0.12 ng/ml) (n = 56) were compared with those with normal cTnI (cTnI < 0.12 ng/ml) (n = 115) at 2 years for the occurrence of major adverse cardiac or cerebrovascular events (MACCE) (composite of myocardial infarction, unstable angina, hypertensive crisis, pulmonary edema, stroke or transient ischemic attack). At 2 years, MACCE occurred in 40 (71.4%) patients with elevated cTnI compared with 44 (38.3%) patients with normal cTnI [hazard ratio: 2.77; 95% confidence interval (CI): 1.79-4.27; P < 0.001]. Also, patients with elevated cTnI were significantly more likely to have underlying obstructive CAD (odds ratio: 8.97; 95% CI: 1.4-55.9; P < 0.01). In patients with hypertensive crisis, elevated cTnI confers a significantly greater risk of long-term MACCE, and is a strong predictor of obstructive CAD.

  11. [Interpretation of elevated serum troponin levels in end stage renal disease - case 2/2010].

    PubMed

    Artunc, Ferruh; Haap, Michael; Heyne, Nils; Weyrich, Peter; Wolf, Sabine

    2010-02-01

    We report on a female patient with rheumatoid arthritis and end-stage renal-disease following AA-amyloidosis who presented with chest pain to the emergency department. ECG showed no signs of ischemia, echocardiography revealed a concentric left ventricular hypertrophy with increased texture. Serum concentration of troponin I was mildly elevated whereas creatine kinase (CK)/ CK-MB were normal. The chief complaints resolved spontaneously and there was no change in the serum troponin-I and CK/CK-MB concentrations. Coronary heart disease was ruled out by angiography and cardiac involvement of the underlying AA-amyloidosis was diagnosed. After one month, the patient suffered from a syncope complicated by a pelvic ring fracture with hemorrhagic shock and declined chronic dialysis treatment. Patients with end-stage renal disease may exhibit a persisting elevation of serum troponin concentration reflecting the high burden of cardiovascular disease. Myocardial infarction can be distinguished by the lack of increase in serial tests. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  12. Identification of cardiomyocyte nuclei and assessment of ploidy for the analysis of cell turnover.

    PubMed

    Bergmann, Olaf; Zdunek, Sofia; Alkass, Kanar; Druid, Henrik; Bernard, Samuel; Frisén, Jonas

    2011-01-15

    Assays to quantify myocardial renewal rely on the accurate identification of cardiomyocyte nuclei. We previously ¹⁴C birth dated human cardiomyocytes based on the nuclear localization of cTroponins T and I. A recent report by Kajstura et al. suggested that cTroponin I is only localized to the nucleus in a senescent subpopulation of cardiomyocytes, implying that ¹⁴C birth dating of cTroponin T and I positive cell populations underestimates cardiomyocyte renewal in humans. We show here that the isolation of cell nuclei from the heart by flow cytometry with antibodies against cardiac Troponins T and I, as well as pericentriolar material 1 (PCM-1), allows for isolation of close to all cardiomyocyte nuclei, based on ploidy and marker expression. We also present a reassessment of cardiomyocyte ploidy, which has important implications for the analysis of cell turnover, and iododeoxyuridine (IdU) incorporation data. These data provide the foundation for reliable analysis of cardiomyocyte turnover in humans. Copyright © 2010 Elsevier Inc. All rights reserved.

  13. Prediction of troponin-T degradation using color image texture features in 10d aged beef longissimus steaks.

    PubMed

    Sun, X; Chen, K J; Berg, E P; Newman, D J; Schwartz, C A; Keller, W L; Maddock Carlin, K R

    2014-02-01

    The objective was to use digital color image texture features to predict troponin-T degradation in beef. Image texture features, including 88 gray level co-occurrence texture features, 81 two-dimension fast Fourier transformation texture features, and 48 Gabor wavelet filter texture features, were extracted from color images of beef strip steaks (longissimus dorsi, n = 102) aged for 10d obtained using a digital camera and additional lighting. Steaks were designated degraded or not-degraded based on troponin-T degradation determined on d 3 and d 10 postmortem by immunoblotting. Statistical analysis (STEPWISE regression model) and artificial neural network (support vector machine model, SVM) methods were designed to classify protein degradation. The d 3 and d 10 STEPWISE models were 94% and 86% accurate, respectively, while the d 3 and d 10 SVM models were 63% and 71%, respectively, in predicting protein degradation in aged meat. STEPWISE and SVM models based on image texture features show potential to predict troponin-T degradation in meat. © 2013.

  14. The diagnostic significance of NT-proBNP and troponin I in emergency department patients presenting with palpitations

    PubMed Central

    Ocak, Tarık; Erdem, Alim; Duran, Arif; Tekelioğlu, Ümit Yaşar; Öztürk, Serkan; Ayhan, Suzi Selim; Özlü, Mehmet Fatih; Tosun, Mehmet; Koçoğlu, Hasan; Yazıcı, Mehmet

    2013-01-01

    OBJECTIVE: This prospective study investigated the diagnostic significance of the N-terminal pro-brain natriuretic (NT-proBNP) and troponin I peptides in emergency department patients presenting with palpitations. METHODS: Two groups of patients with palpitations but without documented supraventricular tachycardia were compared: a group with supraventricular tachycardia (n = 49) and a control group (n = 47). Both groups were diagnosed using electrophysiological studies during the study period. Blood samples were obtained from all of the patients to determine the NT-proBNP and troponin I levels within the first hour following arrival in the emergency department. RESULT: The mean NT-proBNP levels were 207.74±197.11 in supraventricular tachyarrhythmia group and 39.99±32.83 pg/mL in control group (p<0.001). To predict supraventricular tachycardia, the optimum NT-proBNP threshold was 61.15 pg/mL, as defined by the receiver operating characteristic (ROC) curve, with a non-significant area under the ROC curve of 0.920 (95% CI, 0.86-0.97, p<0.001). The NT-proBNP cut-off for diagnosing supraventricular tachycardia had 81.6% sensitivity and 91.5% specificity. Supraventricular tachycardia was significantly more frequent in the patients with NT-proBNP levels ≥61.15 pg/mL (n = 44, 90.9%, p>0.001). The mean troponin I levels were 0.17±0.56 and 0.01±0.06 pg/mL for the patients with and without supraventricular tachycardia, respectively (p<0.05). Of the 96 patients, 21 (21.87%) had troponin I levels ≥0.01: 2 (4.25%) in the control group and 19 (38.77%) in the supraventricular tachycardia group (p<0.001). CONCLUSION: Troponin I and, in particular, NT-proBNP peptide were helpful for differentiating supraventricular tachycardia from non- supraventricular tachycardia palpitations. Further randomized, large, multicenter trials are needed to define the benefit and diagnostic role of NT-proBNP and troponin I in the management algorithm of patients presenting with palpitations in emergency departments. PMID:23778331

  15. Rapidly rule out acute myocardial infarction by combining copeptin and heart-type fatty acid-binding protein with cardiac troponin.

    PubMed

    Jacobs, Leo H J; van Borren, Marcel; Gemen, Eugenie; van Eck, Martijn; van Son, Bas; Glatz, Jan F C; Daniels, Marcel; Kusters, Ron

    2015-09-01

    The rapid exclusion of acute myocardial infarction in patients with chest pain can reduce the length of hospital admission, prevent unnecessary diagnostic work-up and reduce the burden on our health-care systems. The combined use of biomarkers that are associated with different pathophysiological aspects of acute myocardial infarction could improve the early diagnostic assessment of patients presenting with chest pain. We measured cardiac troponin I, copeptin and heart-type fatty acid-binding protein concentrations in 584 patients who presented to the emergency department with acute chest pain. The diagnostic performances for the diagnosis of acute myocardial infarction and NSTEMI were calculated for the individual markers and their combinations. Separate calculations were made for patients presenting to the emergency department <3 h, 3-6 h and 6-12 h after chest pain onset. For ruling out acute myocardial infarction, the net predictive values (95% CI) of cardiac troponin I, copeptin and heart-type fatty acid-binding protein were 90.4% (87.3-92.9), 84% (79.8-87.6) and 87% (83.5-90), respectively. Combining the three biomarkers resulted in a net predictive value of 95.8% (92.8-97.8). The improvement was most pronounced in the early presenters (<3 h) where the combined net predictive value was 92.9% (87.3-96.5) compared to 84.6% (79.4-88.9) for cardiac troponin I alone. The area under the receiver operating characteristic for the triple biomarker combination increased significantly (P < 0.05) compared to that of cardiac troponin I alone (0.880 [0.833-0.928] vs. 0.840 [0.781-0.898], respectively). Combining copeptin, heart-type fatty acid-binding protein and cardiac troponin I measurements improves the diagnostic performance in patients presenting with chest pain. Importantly, in patients who present early (<3 h) after chest pain onset, the combination improves the diagnostic performance compared to the standard cardiac troponin I measurement alone. © The Author(s) 2015.

  16. Rapid large-scale purification of myofilament proteins using a cleavable His6-tag.

    PubMed

    Zhang, Mengjie; Martin, Jody L; Kumar, Mohit; Khairallah, Ramzi J; de Tombe, Pieter P

    2015-11-01

    With the advent of high-throughput DNA sequencing, the number of identified cardiomyopathy-causing mutations has increased tremendously. As the majority of these mutations affect myofilament proteins, there is a need to understand their functional consequence on contraction. Permeabilized myofilament preparations coupled with protein exchange protocols are a common method for examining into contractile mechanics. However, producing large quantities of myofilament proteins can be time consuming and requires different approaches for each protein of interest. In the present study, we describe a unified automated method to produce troponin C, troponin T, and troponin I as well as myosin light chain 2 fused to a His6-tag followed by a tobacco etch virus (TEV) protease site. TEV protease has the advantage of a relaxed P1' cleavage site specificity, allowing for no residues left after proteolysis and preservation of the native sequence of the protein of interest. After expression in Esherichia coli, cells were lysed by sonication in imidazole-containing buffer. The His6-tagged protein was then purified using a HisTrap nickel metal affinity column, and the His6-tag was removed by His6-TEV protease digestion for 4 h at 30°C. The protease was then removed using a HisTrap column, and complex assembly was performed via column-assisted sequential desalting. This mostly automated method allows for the purification of protein in 1 day and can be adapted to most soluble proteins. It has the advantage of greatly increasing yield while reducing the time and cost of purification. Therefore, production and purification of mutant proteins can be accelerated and functional data collected in a faster, less expensive manner. Copyright © 2015 the American Physiological Society.

  17. Fluorescent Protein-Based Ca2+ Sensor Reveals Global, Divalent Cation-Dependent Conformational Changes in Cardiac Troponin C.

    PubMed

    Badr, Myriam A; Pinto, Jose R; Davidson, Michael W; Chase, P Bryant

    2016-01-01

    Cardiac troponin C (cTnC) is a key effector in cardiac muscle excitation-contraction coupling as the Ca2+ sensing subunit responsible for controlling contraction. In this study, we generated several FRET sensors for divalent cations based on cTnC flanked by a donor fluorescent protein (CFP) and an acceptor fluorescent protein (YFP). The sensors report Ca2+ and Mg2+ binding, and relay global structural information about the structural relationship between cTnC's N- and C-domains. The sensors were first characterized using end point titrations to decipher the response to Ca2+ binding in the presence or absence of Mg2+. The sensor that exhibited the largest responses in end point titrations, CTV-TnC, (Cerulean, TnC, and Venus) was characterized more extensively. Most of the divalent cation-dependent FRET signal originates from the high affinity C-terminal EF hands. CTV-TnC reconstitutes into skinned fiber preparations indicating proper assembly of troponin complex, with only ~0.2 pCa unit rightward shift of Ca2+-sensitive force development compared to WT-cTnC. Affinity of CTV-TnC for divalent cations is in agreement with known values for WT-cTnC. Analytical ultracentrifugation indicates that CTV-TnC undergoes compaction as divalent cations bind. C-terminal sites induce ion-specific (Ca2+ versus Mg2+) conformational changes in cTnC. Our data also provide support for the presence of additional, non-EF-hand sites on cTnC for Mg2+ binding. In conclusion, we successfully generated a novel FRET-Ca2+ sensor based on full length cTnC with a variety of cellular applications. Our sensor reveals global structural information about cTnC upon divalent cation binding.

  18. Rapid large-scale purification of myofilament proteins using a cleavable His6-tag

    PubMed Central

    Zhang, Mengjie; Martin, Jody L.; Kumar, Mohit; de Tombe, Pieter P.

    2015-01-01

    With the advent of high-throughput DNA sequencing, the number of identified cardiomyopathy-causing mutations has increased tremendously. As the majority of these mutations affect myofilament proteins, there is a need to understand their functional consequence on contraction. Permeabilized myofilament preparations coupled with protein exchange protocols are a common method for examining into contractile mechanics. However, producing large quantities of myofilament proteins can be time consuming and requires different approaches for each protein of interest. In the present study, we describe a unified automated method to produce troponin C, troponin T, and troponin I as well as myosin light chain 2 fused to a His6-tag followed by a tobacco etch virus (TEV) protease site. TEV protease has the advantage of a relaxed P1′ cleavage site specificity, allowing for no residues left after proteolysis and preservation of the native sequence of the protein of interest. After expression in Esherichia coli, cells were lysed by sonication in imidazole-containing buffer. The His6-tagged protein was then purified using a HisTrap nickel metal affinity column, and the His6-tag was removed by His6-TEV protease digestion for 4 h at 30°C. The protease was then removed using a HisTrap column, and complex assembly was performed via column-assisted sequential desalting. This mostly automated method allows for the purification of protein in 1 day and can be adapted to most soluble proteins. It has the advantage of greatly increasing yield while reducing the time and cost of purification. Therefore, production and purification of mutant proteins can be accelerated and functional data collected in a faster, less expensive manner. PMID:26386113

  19. Mini-thin filaments regulated by troponin–tropomyosin

    PubMed Central

    Gong, Huiyu; Hatch, Victoria; Ali, Laith; Lehman, William; Craig, Roger; Tobacman, Larry S.

    2005-01-01

    Striated muscle thin filaments contain hundreds of actin monomers and scores of troponins and tropomyosins. To study the cooperative mechanism of thin filaments, “mini-thin filaments” were generated by isolating particles nearly matching the minimal structural repeat of thin filaments: a double helix of actin subunits with each strand approximately seven actins long and spanned by a troponin–tropomyosin complex. One end of the particles was capped by a gelsolin (segment 1–3)–TnT fusion protein (substituting for normal TnT), and the other end was capped by tropomodulin. EM showed that the particles were 46 ± 9 nm long, with a knob-like mass attributable to gelsolin at one end. Average actin, tropomyosin, and gelsolin–troponin composition indicated one troponin–tropomyosin attached to each strand of the two-stranded actin filament. The minifilaments thus nearly represent single regulatory units of thin filaments. The myosin S1 MgATPase rate stimulated by the minifilaments was Ca2+-sensitive, indicating that single regulatory length particles are sufficient for regulation. Ca2+ bound cooperatively to cardiac TnC in conventional thin filaments but noncooperatively to cardiac TnC in minifilaments in the absence of myosin. This suggests that thin filament Ca2+-binding cooperativity reflects indirect troponin–troponin interactions along the long axis of conventional filaments, which do not occur in minifilaments. Despite noncooperative Ca2+ binding to minifilaments in the absence of myosin, Ca2+ cooperatively activated the myosin S1-particle ATPase rate. Two-stranded single regulatory units therefore may be sufficient for myosin-mediated Ca2+-binding cooperativity. Functional mini-thin filaments are well suited for biochemical and structural analysis of thin-filament regulation. PMID:15644437

  20. A sting from an unknown jellyfish species associated with persistent symptoms and raised troponin I levels.

    PubMed

    McD Taylor, David; Pereira, Peter; Seymour, Jamie; Winkel, Kenneth D

    2002-06-01

    We describe a patient stung by an unknown jellyfish species offshore in Far North Queensland. The sting caused immediate and severe pain, multiple whip-like skin lesions and constitutional symptoms. The jellyfish tentacular nematocysyts were similar to, but distinct from, those of Carukia barnesi, a cause of the 'Irukandji' syndrome. The patients symptoms largely resolved over seven months and were associated with elevated cardiac troponin levels, in the absence of other evidence of cardiac disease. This case highlights the envenomation risks associated with marine recreation, and the need for critical evaluation of cardiac troponin assays and for further research in marine toxicology.

  1. Highly-sensitive troponin I is increased in patients with gynecological cancers.

    PubMed

    Danese, Elisa; Montagnana, Martina; Giudici, Silvia; Aloe, Rosalia; Franchi, Massimo; Guidi, Gian Cesare; Lippi, Giuseppe

    2013-08-01

    To investigate troponin I (TnI) in patients with gynecological cancers. Highly-sensitive (HS) and conventional TnI were measured in 25 patients with untreated ovarian cancer, 25 with endometriosis and 25 with benign masses. Both HS and conventional TnI were increase in cancer patients. Values above the cut-off were found in 44% and 16% cancer patients using HS and conventional TnI methods, respectively. Cardiac involvement is frequent in patients with gynecological cancers and should be preferably assessed using HS troponin immunoassays. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. The diagnostic value of troponin in critically ill.

    PubMed

    Voga, Gorazd

    2010-01-01

    Troponin T and I are sensitive and specific markers of myocardial necrosis. They are used for the routine diagnosis of acute coronary syndrome. In critically ill patients they are basic diagnostic tool for diagnosis of myocardial necrosis due to myocardial ischemia. Moreover, the increase of troponin I and T is related with adverse outcome in many subgroups of critically ill patients. The new, high sensitivity tests which have been developed recently allow earlier and more accurate diagnosis of acute coronary syndrome. The use of the new tests has not been studied in critically ill patients, but they will probably replace the old tests and will be used on the routine basis.

  3. Isoform variants of troponin in skeletal and cardiac muscle cells cultured with and without nerves.

    PubMed

    Toyota, N; Shimada, Y

    1983-05-01

    Immunofluorescence microscopy shows that cultured skeletal and cardiac muscle cells of chicken embryos exhibit the same stainabilities with antibodies against skeletal and cardiac troponin components as do those in embryos. Muscle cells of each type cultured with motor or sympathetic nerves or in medium containing the nerve extract exhibit the same reactivities as do those in adult animals. Cardiac muscle cells incubated in the nerve-conditioned medium also change the form of troponin components to the adult type. It appears that the differentiation of individual muscle fibers to specific types is induced by nerves, and especially by the neurohumoral effect.

  4. Association of High-Sensitivity Cardiac Troponin I Concentration With Cardiac Outcomes in Patients With Suspected Acute Coronary Syndrome

    PubMed Central

    Chapman, Andrew R.; Lee, Kuan Ken; McAllister, David A.; Cullen, Louise; Greenslade, Jaimi H.; Parsonage, William; Worster, Andrew; Kavsak, Peter A.; Blankenberg, Stefan; Neumann, Johannes; Söerensen, Nils A.; Westermann, Dirk; Buijs, Madelon M.; Verdel, Gerard J. E.; Pickering, John W.; Than, Martin P.; Twerenbold, Raphael; Badertscher, Patrick; Sabti, Zaid; Mueller, Christian; Anand, Atul; Adamson, Philip; Strachan, Fiona E.; Ferry, Amy; Sandeman, Dennis; Gray, Alasdair; Body, Richard; Keevil, Brian; Carlton, Edward; Greaves, Kim; Korley, Frederick K.; Metkus, Thomas S.; Sandoval, Yader; Apple, Fred S.; Newby, David E.; Shah, Anoop S. V.

    2017-01-01

    Importance High-sensitivity cardiac troponin I testing is widely used to evaluate patients with suspected acute coronary syndrome. A cardiac troponin concentration of less than 5 ng/L identifies patients at presentation as low risk, but the optimal threshold is uncertain. Objective To evaluate the performance of a cardiac troponin I threshold of 5 ng/L at presentation as a risk stratification tool in patients with suspected acute coronary syndrome. Data Sources Systematic search of MEDLINE, EMBASE, Cochrane, and Web of Science databases from January 1, 2006, to March 18, 2017. Study Selection Prospective studies measuring high-sensitivity cardiac troponin I concentrations in patients with suspected acute coronary syndrome in which the diagnosis was adjudicated according to the universal definition of myocardial infarction. Data Extraction and Synthesis The systematic review identified 19 cohorts. Individual patient-level data were obtained from the corresponding authors of 17 cohorts, with aggregate data from 2 cohorts. Meta-estimates for primary and secondary outcomes were derived using a binomial-normal random-effects model. Main Outcomes and Measures The primary outcome was myocardial infarction or cardiac death at 30 days. Performance was evaluated in subgroups and across a range of troponin concentrations (2-16 ng/L) using individual patient data. Results Of 11 845 articles identified, 104 underwent full-text review, and 19 cohorts from 9 countries were included. Among 22 457 patients included in the meta-analysis (mean age, 62 [SD, 15.5] years; n = 9329 women [41.5%]), the primary outcome occurred in 2786 (12.4%). Cardiac troponin I concentrations were less than 5 ng/L at presentation in 11 012 patients (49%), in whom there were 60 missed index or 30-day events (59 index myocardial infarctions, 1 myocardial infarction at 30 days, and no cardiac deaths at 30 days). This resulted in a negative predictive value of 99.5% (95% CI, 99.3%-99.6%) for the primary outcome. There were no cardiac deaths at 30 days and 7 (0.1%) at 1 year, with a negative predictive value of 99.9% (95% CI, 99.7%-99.9%) for cardiac death. Conclusions and Relevance Among patients with suspected acute coronary syndrome, a high-sensitivity cardiac troponin I concentration of less than 5 ng/L identified those at low risk of myocardial infarction or cardiac death within 30 days. Further research is needed to understand the clinical utility and cost-effectiveness of this approach to risk stratification. PMID:29127948

  5. Association of High-Sensitivity Cardiac Troponin I Concentration With Cardiac Outcomes in Patients With Suspected Acute Coronary Syndrome.

    PubMed

    Chapman, Andrew R; Lee, Kuan Ken; McAllister, David A; Cullen, Louise; Greenslade, Jaimi H; Parsonage, William; Worster, Andrew; Kavsak, Peter A; Blankenberg, Stefan; Neumann, Johannes; Sörensen, Nils A; Westermann, Dirk; Buijs, Madelon M; Verdel, Gerard J E; Pickering, John W; Than, Martin P; Twerenbold, Raphael; Badertscher, Patrick; Sabti, Zaid; Mueller, Christian; Anand, Atul; Adamson, Philip; Strachan, Fiona E; Ferry, Amy; Sandeman, Dennis; Gray, Alasdair; Body, Richard; Keevil, Brian; Carlton, Edward; Greaves, Kim; Korley, Frederick K; Metkus, Thomas S; Sandoval, Yader; Apple, Fred S; Newby, David E; Shah, Anoop S V; Mills, Nicholas L

    2017-11-21

    High-sensitivity cardiac troponin I testing is widely used to evaluate patients with suspected acute coronary syndrome. A cardiac troponin concentration of less than 5 ng/L identifies patients at presentation as low risk, but the optimal threshold is uncertain. To evaluate the performance of a cardiac troponin I threshold of 5 ng/L at presentation as a risk stratification tool in patients with suspected acute coronary syndrome. Systematic search of MEDLINE, EMBASE, Cochrane, and Web of Science databases from January 1, 2006, to March 18, 2017. Prospective studies measuring high-sensitivity cardiac troponin I concentrations in patients with suspected acute coronary syndrome in which the diagnosis was adjudicated according to the universal definition of myocardial infarction. The systematic review identified 19 cohorts. Individual patient-level data were obtained from the corresponding authors of 17 cohorts, with aggregate data from 2 cohorts. Meta-estimates for primary and secondary outcomes were derived using a binomial-normal random-effects model. The primary outcome was myocardial infarction or cardiac death at 30 days. Performance was evaluated in subgroups and across a range of troponin concentrations (2-16 ng/L) using individual patient data. Of 11 845 articles identified, 104 underwent full-text review, and 19 cohorts from 9 countries were included. Among 22 457 patients included in the meta-analysis (mean age, 62 [SD, 15.5] years; n = 9329 women [41.5%]), the primary outcome occurred in 2786 (12.4%). Cardiac troponin I concentrations were less than 5 ng/L at presentation in 11 012 patients (49%), in whom there were 60 missed index or 30-day events (59 index myocardial infarctions, 1 myocardial infarction at 30 days, and no cardiac deaths at 30 days). This resulted in a negative predictive value of 99.5% (95% CI, 99.3%-99.6%) for the primary outcome. There were no cardiac deaths at 30 days and 7 (0.1%) at 1 year, with a negative predictive value of 99.9% (95% CI, 99.7%-99.9%) for cardiac death. Among patients with suspected acute coronary syndrome, a high-sensitivity cardiac troponin I concentration of less than 5 ng/L identified those at low risk of myocardial infarction or cardiac death within 30 days. Further research is needed to understand the clinical utility and cost-effectiveness of this approach to risk stratification.

  6. Preprocedural statin therapy reduces the risk and extent of cardiac biomarker release following percutaneous coronary intervention.

    PubMed

    Veselka, Josef; Procházková, Sárka; Duchonová, Radka; Homolová, Ingrid; Tesar, David; Bybee, Kevin A

    2006-05-01

    This study evaluates the association between statin therapy in patients treated by percutaneous coronary intervention (PCI) for stable angina pectoris and postinterventional myocardial injury with subsequent long-term clinical outcome. Prospectively collected data on 400 consecutive patients with stable angina pectoris or evidence of inducible myocardial ischemia were analyzed. The incidence of myocardial infarction based on postinterventional release of troponin I>1.5 ng/ml was 12% in the statin pretreated patients and 20% in those not pretreated with statin therapy (P=0.04, odds ratio 1.84, 95% confidence interval 1.06-3.21). Of the patients experiencing a post-PCI troponin elevation>1.5 ng/ml, those pretreated with a statin pre-PCI had a lesser troponin elevation compared with those not receiving a statin pre-PCI (median: 2.9 ng/ml [1.9-11.5] vs 5.0 ng/ml [3.1-8.8]; P<0.001). In the multivariate model, preprocedural statin therapy was identified as the only independent negative predictor of procedure-related myocardial necrosis based on postprocedural troponin elevation. In the 21-month follow-up period, statin pretreated patients were observed to have fewer deaths, revascularizations, or myocardial infarction; however, this difference was not statistically significant. These results suggest that pretreatment with statins in patients undergoing PCI for stable angina pectoris reduces the risk and extent of procedure-related myocardial injury measured by troponin release.

  7. Nemaline myopathy and distal arthrogryposis associated with an autosomal recessive TNNT3 splice variant.

    PubMed

    Sandaradura, Sarah A; Bournazos, Adam; Mallawaarachchi, Amali; Cummings, Beryl B; Waddell, Leigh B; Jones, Kristi J; Troedson, Christopher; Sudarsanam, Annapurna; Nash, Benjamin M; Peters, Gregory B; Algar, Elizabeth M; MacArthur, Daniel G; North, Kathryn N; Brammah, Susan; Charlton, Amanda; Laing, Nigel G; Wilson, Meredith J; Davis, Mark R; Cooper, Sandra T

    2018-03-01

    A male neonate presented with severe weakness, hypotonia, contractures and congenital scoliosis. Skeletal muscle specimens showed marked atrophy and degeneration of fast fibers with striking nemaline rods and hypertrophy of slow fibers that were ultrastructurally normal. A neuromuscular gene panel identified a homozygous essential splice variant in TNNT3 (chr11:1956150G > A, NM_006757.3:c.681+1G > A). TNNT3 encodes skeletal troponin-T fast and is associated with autosomal dominant distal arthrogryposis. TNNT3 has not previously been associated with nemaline myopathy (NM), a rare congenital myopathy linked to defects in proteins associated with thin filament structure and regulation. cDNA studies confirmed pathogenic consequences of the splice variant, eliciting exon-skipping and intron retention events leading to a frameshift. Western blot showed deficiency of troponin-T fast protein with secondary loss of troponin-I fast . We establish a homozygous splice variant in TNNT3 as the likely cause of severe congenital NM with distal arthrogryposis, characterized by specific involvement of Type-2 fibers and deficiency of troponin-T fast . © 2017 Wiley Periodicals, Inc.

  8. Elevation in serum troponin I predicts the benefit of tirofiban.

    PubMed

    Januzzi, J L; Chae, C U; Sabatine, M S; Jang, I K

    2001-05-01

    Elevations in serum troponins among patients with acute coronary syndromes have been shown to identify those patients who are at high risk for poor outcome and who accrue larger relative benefits from aggressive antiplatelet and antithrombotic therapies. We studied a group of patients from the PRISM-PLUS trial to explore whether simply using serum troponin I, a serum marker of cardiac injury, could predict benefit of GP IIb/IIIa receptor antagonism with tirofiban. For this study, the subjects consisted of 55 patients receiving the combination therapy of tirofiban/heparin, and 55 receiving heparin alone. The baseline characteristics were similar between the two treatment groups. Serial blood samples were obtained over the first 24-hour period following randomization to study drug, and were analyzed for troponin I (TnI) levels. Among those patients with elevated serum TnI (>0.5 ng/ml), the 30-day event rate for death or myocardial infarction (MI) was reduced from 20.6% among the heparin only group to 3.6% for those treated with the combination of tirofiban/heparin, an absolute risk reduction of 17% and relative risk reduction of 83% (p=0.06). Among the TnI negative patients, the rates of death/MI at 30 days were 9.5% and 11.1% among the combination and heparin treated groups respectively (p=NS). Irrespective of high-risk clinical factors, including ST segment depression, these data support the hypothesis that serum troponins identify those who benefit from aggressive antiplatelet therapy with tirofiban.

  9. Sequential N-Terminal Pro-B-Type Natriuretic Peptide and High-Sensitivity Cardiac Troponin Measurements During Albumin Replacement in Patients With Severe Sepsis or Septic Shock.

    PubMed

    Masson, Serge; Caironi, Pietro; Fanizza, Caterina; Carrer, Sara; Caricato, Anselmo; Fassini, Paola; Vago, Tarcisio; Romero, Marilena; Tognoni, Gianni; Gattinoni, Luciano; Latini, Roberto

    2016-04-01

    Myocardial dysfunction is a frequent complication in patients with severe sepsis and can worsen the prognosis. We investigated whether circulating biomarkers related to myocardial function and injury predicted outcome and were associated with albumin replacement. A multicenter, randomized clinical trial about albumin replacement in severe sepsis or septic shock (the Albumin Italian Outcome Sepsis trial). Forty ICUs in Italy. Nine hundred and ninety-five patients with severe sepsis or septic shock. Randomization to albumin and crystalloid solutions or crystalloid solutions alone. Plasma concentrations of N- terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin T were measured 1, 2, and 7 days after enrollment. We tested the relationship of single marker measurements or changes over time with clinical events, organ dysfunctions, albumin replacement, and ICU or 90-day mortality in the overall population and after stratification by shock. N-terminal pro-B-type natriuretic peptide levels were abnormal in 97.4% of the patients and high-sensitivity cardiac troponin T in 84.5%, with higher concentrations in those with shock. After extensive adjustments, N-terminal pro-B-type natriuretic peptide concentrations predicted ICU or 90-day mortality, better than high-sensitivity cardiac troponin T. Early changes in N-terminal pro-B-type natriuretic peptide or high-sensitivity cardiac troponin T concentrations were independently associated with subsequent mortality in patients with shock. Patients given albumin had significantly higher N-terminal pro-B-type natriuretic peptide levels; in addition, early rise in N-terminal pro-B-type natriuretic peptide was associated with a better outcome in this subgroup. Circulating N-terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin T are frequently elevated in severe sepsis or septic shock and have relevant prognostic value, which may be important in monitoring the clinical efficacy of supporting therapy.

  10. Cost effectiveness of high-sensitivity troponin compared to conventional troponin among patients presenting with undifferentiated chest pain: A trial based analysis.

    PubMed

    Kaambwa, Billingsley; Ratcliffe, Julie; Horsfall, Matthew; Astley, Carolyn; Karnon, Jonathan; Coates, Penelope; Arstall, Margaret; Zeitz, Christopher; Worthley, Matthew; Beltrame, John; Chew, Derek P

    2017-07-01

    Patients with low and intermediate risk chest pain features comprise the greatest proportion presenting to emergency services for evaluation of suspected acute coronary syndromes (ACS). The efficient and timely identification of patients with these features remains a major challenge within clinical practice. Troponin assays are increasingly being used for the determination of risk among patients presenting with chest pain potentially facilitating more appropriate care. To date, no economic evaluation comparing high-sensitivity troponin T (hs-TnT) reporting to standard troponin T (c-TnT) reporting in the routine management of suspected ACS and based on longer-term clinical outcomes has been conducted. An economic evaluation was conducted with 1937 participants randomized to either hs-TnT (n=973) or c-TnT (n=964) with 12month follow-up. The primary outcome measure was the number of cumulative combined outcomes of all-cause mortality and new or recurrent ACS avoided. Mean per participant Australian Medicare costs were higher in the hs-TnT arm compared to the c-TnT arm (by $1285/patient). Mean total adverse clinical outcomes avoided were higher in the hs-TnT arm (by 0.0120/patient) resulting in an incremental cost-effectiveness ratio (ICER) of $108,552/adverse clinical outcome avoided. An ICER of $49,030/adverse clinical outcome avoided was obtained when the analysis was restricted to patients below the threshold of normal Troponin testing (actual c-TnT levels <30ng/L). hs-TnT reporting leads to fewer adverse clinical events but at a high ICER. For the routine implementation of hs-TnT to be more cost-effective, substantial changes in clinical practice will be required. Australian New Zealand Clinical Trials Registry (ACTRN12614000189628). https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=365726. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Q10 supplementation effects on cardiac enzyme CK-MB and troponin in patients undergoing coronary artery bypass graft: a randomized, double-blinded, placebo-controlled clinical trial

    PubMed Central

    Moludi, Jalal; Keshavarz, Seyedali; Tabaee, Ali Sadeghpour; Safiri, Saeid; Pakzad, Reza

    2016-01-01

    Introduction: Coronary artery bypass surgery (CABG) is associated with ischemia-reperfusion injury and tissue damage. CoQ10 as an antioxidant has an important role and may have cardio-protective effects after myocardial dysfunction and CABG. We aimed to evaluate whether CoQ10 has a myocardial cardio protective impact on cardiac biomarkers after CABG. Methods: In this double-blind study, 80 patients with coronary artery disease (CAD) who underwent CABG surgery were divided into intervention and control groups and received Q10 supplement or placebo, respectively. The surgical characteristics of the patients in the two groups were similar. The intervention group received 150 mg of Q10 supplement per day for 7 days before the surgery. The control group received placebo capsule. After operation the inter- and intra-group blood levels of CK-MB and troponin, before and after supplementation and 12 hours after the CABG, and postoperative outcomes such as intensive care unit (ICU) stay and hospital stay were compared. Results: In this study, 40 subjects were located in each group. The participation rate was 97.5% and men and women accounted for 52.5% and 47.5% respectively. The mean age of the subjects was 58.17 ± 8.55. The two groups were not significantly different in terms of basic variables. Within-group comparison showed a significant increase in the level of troponin enzymes over time (P < 0.001) and CK-MB (P < 0.001). However, between-group comparison showed no significant difference between the two groups in terms of CK-MB (P = 0.384) and troponin (P = 0.115). In the end, no interaction was observed between the intervention and time on CK-MB (P = 0.095) and troponin (P = 0.198) variables. Conclusion: Q10 supplementation 7 days before surgery was not effective in reducing CK-MB and troponin after CABG. PMID:27069560

  12. Prognosis of patients with non-ST-segment-elevation myocardial infarction and nonobstructive coronary artery disease: propensity-matched analysis from the Acute Catheterization and Urgent Intervention Triage Strategy trial.

    PubMed

    Planer, David; Mehran, Roxana; Ohman, E Magnus; White, Harvey D; Newman, Jonathan D; Xu, Ke; Stone, Gregg W

    2014-06-01

    Troponin elevation is a risk factor for mortality in patients with non-ST-segment-elevation acute coronary syndromes. However, the prognosis of patients with troponin elevation and nonobstructive coronary artery disease (CAD) is unknown. Our objective was therefore to evaluate the impact of nonobstructive CAD in patients with non-ST-segment-elevation acute coronary syndromes and troponin elevation enrolled in the Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trial. In the ACUITY trial, 3-vessel quantitative coronary angiography was performed in a formal substudy of 6921 patients presenting with non-ST-segment-elevation acute coronary syndromes. Patients with elevated admission troponin levels were stratified by the presence or absence of obstructive CAD (any lesion with quantitative diameter stenosis >50%). Propensity score matching was performed to adjust for baseline characteristics. Of 2442 patients with elevated troponin, 197 (8.8%) had nonobstructive CAD. Maximum diameter stenosis was 87.4 (73.2, 100.0) versus 22.6 (19.2, 25.7; P<0.0001) in patients with versus without obstructive CAD, respectively. Propensity matching yielded 117 patients with nonobstructive CAD and 331 patients with obstructive CAD, with no significant baseline differences between groups. In the matched cohort, overall 1-year mortality was significantly higher in patients with nonobstructive CAD (5.2% versus 1.6%; hazard ratio [95% confidence interval]=3.44 [1.05, 11.28]; P=0.04), driven by greater noncardiac mortality. Conversely, recurrent myocardial infarction and unplanned revascularization rates were significantly higher in patients with obstructive CAD. Patients with non-ST-segment-elevation acute coronary syndromes and elevated troponin levels but without obstructive CAD, while having low rates of subsequent myocardial infarction and unplanned revascularization, are still at considerable risk for 1-year mortality from noncardiac causes. http://www.clinicaltrials.gov. Unique identifier: NCT00093158. © 2014 American Heart Association, Inc.

  13. Metal ring on 4th or 5th finger markedly increases both cardiac troponin I at left ventricle and cancer-related parameters such as oncogen C-fosAb2 & integrin α₅β₁[corrected] by 4-12 times. Thus these metal rings appear to promote both heart problems & cancer.

    PubMed

    Omura, Yoshiaki; Hines, Howard; Jones, Marilyn; O'Young, Brian; Duvvi, Harsha; Lu, Dominic P; Pallos, Andrew; Shimotsuura, Yasuhiro; Ohki, Motomu

    2010-01-01

    We examined patients wearing a metal ring on the left 4th finger with abnormally increased Cardiac Troponin I (which is known to increase in the presence of myocardial injury or left ventricular hypertrophy) of 5-14ng BDORT units (depending on the ring and individual) at left ventricle compared with normal value of 1ng BDORT units or less. Although shape of the ECG does not change significantly regardless of whether metal rings are on or not, when rings are on, the Bi-Digital O-Ring Test evaluation of trace of ECG revealed "Vulnerable Period of Rising Part of T-wave" of ECG waves (which correspond to the left ventricle and AV node) become abnormal with increased Cardiac Troponin I. DHEA in various parts of the body reduced significantly and maximum decrease in DHEA was found when metal ring was on the left 4th and 5th fingers. Telomere reduced with each of the 5 fingers, but the 2nd, 4th, and 5th fingers produced the maximum reduction of telomere. When metal ring was inserted onto the left 1st finger and left 2nd finger, Cardiac Troponin I did not change significantly. Additional abnormality was found when patients with cancer wore metal ring(s); namely both Cardiac Troponin I and cancer parameters, such as Integrin α₅β₁[corrected] and Oncogen C-fos Ab2, increase anywhere between 4-12 times. However, when the ring was cut, creating a 1mm or longer empty space, no increase in cancer markers and Cardiac Troponin I were observed. Similar findings were found with metal bracelets.

  14. High-Sensitivity Cardiac Troponin and the Risk Stratification of Patients With Renal Impairment Presenting With Suspected Acute Coronary Syndrome

    PubMed Central

    Miller-Hodges, Eve; Anand, Atul; Shah, Anoop S.V.; Chapman, Andrew R.; Gallacher, Peter; Lee, Kuan Ken; Farrah, Tariq; Halbesma, Nynke; Blackmur, James P.; Newby, David E.; Mills, Nicholas L.

    2018-01-01

    Background: High-sensitivity cardiac troponin testing may improve the risk stratification and diagnosis of myocardial infarction, but concentrations can be challenging to interpret in patients with renal impairment, and the effectiveness of testing in this group is uncertain. Methods: In a prospective multicenter study of consecutive patients with suspected acute coronary syndrome, we evaluated the performance of high-sensitivity cardiac troponin I in those with and without renal impairment (estimated glomerular filtration rate <60mL/min/1.73m2). The negative predictive value and sensitivity of troponin concentrations below the risk stratification threshold (5 ng/L) at presentation were reported for a primary outcome of index type 1 myocardial infarction, or type 1 myocardial infarction or cardiac death at 30 days. The positive predictive value and specificity at the 99th centile diagnostic threshold (16 ng/L in women, 34 ng/L in men) was determined for index type 1 myocardial infarction. Subsequent type 1 myocardial infarction and cardiac death were reported at 1 year. Results: Of 4726 patients identified, 904 (19%) had renal impairment. Troponin concentrations <5 ng/L at presentation identified 17% of patients with renal impairment as low risk for the primary outcome (negative predictive value, 98.4%; 95% confidence interval [CI], 96.0%–99.7%; sensitivity 98.9%; 95%CI, 97.5%–99.9%), in comparison with 56% without renal impairment (P<0.001) with similar performance (negative predictive value, 99.7%; 95% CI, 99.4%–99.9%; sensitivity 98.4%; 95% CI, 97.2%–99.4%). The positive predictive value and specificity at the 99th centile were lower in patients with renal impairment at 50.0% (95% CI, 45.2%–54.8%) and 70.9% (95% CI, 67.5%–74.2%), respectively, in comparison with 62.4% (95% CI, 58.8%–65.9%) and 92.1% (95% CI, 91.2%–93.0%) in those without. At 1 year, patients with troponin concentrations >99th centile and renal impairment were at greater risk of subsequent myocardial infarction or cardiac death than those with normal renal function (24% versus 10%; adjusted hazard ratio, 2.19; 95% CI, 1.54–3.11). Conclusions: In suspected acute coronary syndrome, high-sensitivity cardiac troponin identified fewer patients with renal impairment as low risk and more as high risk, but with lower specificity for type 1 myocardial infarction. Irrespective of diagnosis, patients with renal impairment and elevated cardiac troponin concentrations had a 2-fold greater risk of a major cardiac event than those with normal renal function, and should be considered for further investigation and treatment. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01852123. PMID:28978551

  15. Photoluminescence analysis of self induced planer alignment in azo dye dispersed nematic liquid crystal complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Rishi, E-mail: kkraina@gmail.com; Sood, Srishti, E-mail: kkraina@gmail.com; Raina, K. K., E-mail: kkraina@gmail.com

    2014-04-24

    We have developed azo dye doped nematic liquid crystal complex for advanced photonic liquid crystal display technology aspects. Disperse orange azo dye self introduced planer alignment in the nematic liquid crystal without any surface anchoring treatment. Planer alignment was characterized by optical polarizing microscopy. The electro-optical switching response of dye disperse planer aligned nematic cell was investigated as a function of applied voltage with the help of photoluminescence spectrophotometer for the tuning of photoluminescence contrast.

  16. Preparation of a porous conductive scaffold from aniline pentamer-modified polyurethane/PCL blend for cardiac tissue engineering.

    PubMed

    Baheiraei, Nafiseh; Yeganeh, Hamid; Ai, Jafar; Gharibi, Reza; Ebrahimi-Barough, Somayeh; Azami, Mahmoud; Vahdat, Sadaf; Baharvand, Hossein

    2015-10-01

    A novel biodegradable electroactive polyurethane containing aniline pentamer (AP) was blended with polycaprolactone (PCL). The prepared blend (PB) and PCL were further fabricated in to scaffolds using a mixture of poly(ethylene glycol) and salt particles in a double porogen particulate leaching and compression molding methodology. Scaffolds held open and interconnected pores having pore size ranging from several μm to 150 µm. PB scaffolds had compression modulus and strength of 4.1 and 1.3 MPa, respectively. The conductivity of the scaffold was measured as 10(-5) ± 0.09 S .cm(-1) and preserved for at least 100 h post fabrication. Scaffolds supported neonatal cardiomyocytes adhesion and growth with PB showing more extensive effect on the expression of the cardiac genes involved in muscle contraction and relaxation (troponin-T) and cytoskeleton alignment (actinin-4). Our results highlight the potential of incorporation of AP as an electroactive moiety for induction of cardiomyocyte proliferation and repair of damaged heart tissue. © 2015 Wiley Periodicals, Inc.

  17. Skeletal muscle troponin as a novel biomarker to enhance assessment of the impact of strength training on fall prevention in the older adults.

    PubMed

    Abreu, Eduardo L; Cheng, An-Lin; Kelly, Patricia J; Chertoff, Keyna; Brotto, Leticia; Griffith, Elizabeth; Kinder, Glenda; Uridge, Tina; Zachow, Rob; Brotto, Marco

    2014-01-01

    Loss of muscle mass and strength (i.e., sarcopenia) in the older adults is a strong predictor of falls, with subsequent morbidity and inability to execute activities of daily living. Use of biomarkers may enhance assessment of effects of community-based exercise interventions aimed at improving muscle strength. The aim of this study was to investigate the use of troponin as a newly proposed biomarker of skeletal muscle health when determining the outcomes of strength-training programs designed for community-dwelling adults over the age of 65 years. Outcomes of two strength training programs ("Peer Exercise Program Promotes Independence" and "Stay Strong, Stay Healthy") were assessed using physical performance tests designed for senior fitness evaluation, grip strength, and changes in serum levels of skeletal muscle-specific troponin T (sTnT). Improvement in physical performance, including a significant increase in grip strength, was associated with a significant reduction in serum levels of sTnT. Findings from these studies suggest that, when "Peer Exercise Program Promotes Independence" and "Stay Strong, Stay Healthy" are implemented for at least 10 weeks, significant gains in strength are achieved. This strength improvement was associated with a reduction in serum levels of troponin, supporting the use of troponin as a novel biomarker of muscle health in the assessment of strength training programs for the older adults. Reduced sTnT after exercise intervention suggests that skeletal muscles become stronger and less susceptible to damage because of the exercise regimens.

  18. The HEART score with high-sensitive troponin T at presentation: ruling out patients with chest pain in the emergency room.

    PubMed

    Santi, Luca; Farina, Gabriele; Gramenzi, Annagiulia; Trevisani, Franco; Baccini, Margherita; Bernardi, Mauro; Cavazza, Mario

    2017-04-01

    The HEART score is a simple scoring system, ranging from 0 to 10, specifically developed for risk stratification of patients with undifferentiated chest pain. It has been validated for the conventional troponin, but not for high-sensitive troponin. We assess a modified version of the HEART score using a single high-sensitivity troponin T dosage at presentation, regardless of symptom duration, and with different ECG criteria to evaluate if the patients with a low HEART score could be safely discharged early. The secondary aim was to confirm a statistically significant difference in each HEART score group (low 0-3, intermediate 4-6, high 7-10) in the occurrence of major adverse cardiac events at 30 and 180 days. We retrospectively analyzed the HEART score of 1597 consecutive patients admitted to the Emergency Department of our Hospital for chest pain between January 1 and June 30, 2014. Of these, 190 did not meet the inclusion criteria and 29 were lost to follow-up. None of the 512 (37.2 %) patients with a low HEART score had an event within 180 days. The difference between the cumulative incidences of events in the three HEART score groups was statistically significant (P < 0.0001). We demonstrate that it might be possible to safely discharge Emergency Department chest pain patients with a low modified HEART score after an initial determination of high-sensitive troponin T, without a prolonged observation period or an additional cardiac testing.

  19. A novel approach to cardiac troponins to improve the diagnostic work-up in chest pain patients.

    PubMed

    Eggers, Kai M; Jaffe, Allan S; Svennblad, Bodil; Lindahl, Bertil

    2012-12-01

    In patients with acute chest pain, current guidelines recommend serial measurements of cardiac troponins at predefined and partly late time points. Consequently, diagnostic assessment in these patients tends to be lengthy and often results in unnecessary admissions. We, therefore, evaluated whether an approach integrating troponin results into the clinical context provided by the individual patient's presentation might facilitate the early diagnostic work-up. In 197 chest pain patients, cardiac troponin I (cTnI; Stratus CS) was measured serially within 12 hours after hospital admission. In patient cohorts with different chances of having myocardial infarction (MI) according to clinical data, electrocardiographic findings, and admission biomarker results, pretest probabilities for MI were calculated and compared with posttest probabilities derived from subsequent cTnI results after admission. Elevated cTnI levels at 1 to 2 hours after admission revealed ≥95.0% posttest probabilities for MI in cohorts with intermediate or high chances of having MI. The posttest probabilities for the absence of MI were 94.7% to 98.2% in cohorts with low or intermediate chances of having MI when cTnI was negative at 2 hours. Troponin testing considering the individual patient's pretest probability of MI seems, in conclusion, to provide clinically useful information already 1 to 2 hours after admission. Such an approach has the potential to identify both patient cohorts in whom early discharge or admittance for further evaluation would be appropriate. This could facilitate the early diagnostic work-up of chest pain patients, thereby improving patient flow and reducing overcrowding in healthcare facilities.

  20. Can venous ProBNP levels predict placenta accreta?

    PubMed

    Ersoy, Ali Ozgur; Oztas, Efser; Ozler, Sibel; Ersoy, Ebru; Erkenekli, Kudret; Uygur, Dilek; Caglar, Ali Turhan; Danisman, Nuri

    2016-12-01

    Placenta previa (PP) is a potential life-threatening pregnancy complication. Pro-brain natriuretic peptide (ProBNP), creatine kinase (CK), cardiac form of CK (CK-MB) and Troponin I are circulatory biomarkers related to cardiac functions. We aimed to determine whether these biomarkers are related to PP and placenta accreta. In this case-control study, fifty-four pregnant women who attended our tertiary care center for perinatology with the diagnosis of PP totalis, and of them, 14 patients with placenta accreta were recruited as the study groups. Forty-six uncomplicated control patients who were matched for age, BMI were also included. Maternal venous ProBNP, CK, CK-MB and Troponin I levels were compared between the three groups. Obstetric history characteristics were comparable among groups, generally. CK and CK-MB levels were similar among three groups. Troponin I levels in the previa and accreta groups were significantly higher than the controls. ProBNP levels in the accreta group were significantly higher than other two groups. The multivariate regression model revealed that ProBNP could predict placental adhesion anomalies. Troponin I and ProBNP levels in PP cases were higher than controls and ProBNP could predict placenta accreta.

  1. AlignNemo: a local network alignment method to integrate homology and topology.

    PubMed

    Ciriello, Giovanni; Mina, Marco; Guzzi, Pietro H; Cannataro, Mario; Guerra, Concettina

    2012-01-01

    Local network alignment is an important component of the analysis of protein-protein interaction networks that may lead to the identification of evolutionary related complexes. We present AlignNemo, a new algorithm that, given the networks of two organisms, uncovers subnetworks of proteins that relate in biological function and topology of interactions. The discovered conserved subnetworks have a general topology and need not to correspond to specific interaction patterns, so that they more closely fit the models of functional complexes proposed in the literature. The algorithm is able to handle sparse interaction data with an expansion process that at each step explores the local topology of the networks beyond the proteins directly interacting with the current solution. To assess the performance of AlignNemo, we ran a series of benchmarks using statistical measures as well as biological knowledge. Based on reference datasets of protein complexes, AlignNemo shows better performance than other methods in terms of both precision and recall. We show our solutions to be biologically sound using the concept of semantic similarity applied to Gene Ontology vocabularies. The binaries of AlignNemo and supplementary details about the algorithms and the experiments are available at: sourceforge.net/p/alignnemo.

  2. Preoperative Myocardial Injury as a Predictor of Mortality in Emergency General Surgery: An Analysis Using the American College of Surgeons NSQIP Database.

    PubMed

    Zimmerman, Asha M; Marwaha, Jayson; Nunez, Hector; Harrington, David; Heffernan, Daithi; Monaghan, Sean; Adams, Charles; Stephen, Andrew

    2016-08-01

    Recent studies have linked postoperative serum troponin elevation to mortality in a range of different clinical scenarios. To date, there has been no investigation into the significance of preoperative troponin elevation in emergency general surgery (EGS) patients. We define this as preoperative myocardial injury (PMI). We hypothesize that PMI seen in EGS patients may predict postoperative morbidity and mortality. Using the American College of Surgeons (ACS) National Surgical Quality Improvement Program (NSQIP) database, we performed a retrospective review of all EGS cases between 2008 and 2014. Patients with preoperative troponin I drawn were compared. There were 464 EGS patients who had troponin I measurements preoperatively. Eighty-two (18%) had preoperative troponin elevations. Patients with PMI were more likely to have the following preoperative physiologic derangements: acute renal failure (18% vs 4%; p = 0.002) and septic shock (40% vs 13%; p < 0.001). Patient comorbidities associated with PMI included congestive heart failure (13% vs 3%; p = 0.007), dialysis dependence (16% vs 3%; p = 0.002), and American Society of Anesthesiologists (ASA) class ≥ 4 (52% vs 29%; p < 0.001). Compared with controls, patients with PMI had higher rates of postoperative events (77% vs 52%; p < 0.001) and mortality (34% vs 13%; p = 0.009). Univariate analysis showed that patients with PMI had an increased risk of postoperative events (odds ratio [OR] 3.02; 95% CI 1.74 to 5.25) and mortality (OR 3.53; 95% CI 1.66 to 7.47). Multivariate analysis revealed preoperative troponin I elevation was an independent predictor of mortality (OR 3.03; 95% CI 1.19 to 7.72, p = 0.020). Emergency general surgery patients with PMI are at increased risk for postoperative events and death. Preoperative myocardial injury is an independent predictor of mortality and has prognostic utility that can prepare surgical teams for adverse events so that they can be recognized, evaluated, and treated earlier. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Cardiac Dysfunction in a Porcine Model of Pediatric Malnutrition

    PubMed Central

    Fabiansen, Christian; Lykke, Mikkel; Hother, Anne-Louise; Koch, Jørgen; Nielsen, Ole Bækgaard; Hunter, Ingrid; Goetze, Jens P.; Friis, Henrik; Thymann, Thomas

    2015-01-01

    Background Half a million children die annually of severe acute malnutrition and cardiac dysfunction may contribute to the mortality. However, cardiac function remains poorly examined in cases of severe acute malnutrition. Objective To determine malnutrition-induced echocardiographic disturbances and longitudinal changes in plasma pro-atrial natriuretic peptide and cardiac troponin-T in a pediatric porcine model. Methods and Results Five-week old piglets (Duroc-x-Danish Landrace-x-Yorkshire) were fed a nutritionally inadequate maize-flour diet to induce malnutrition (MAIZE, n = 12) or a reference diet (AGE-REF, n = 12) for 7 weeks. Outcomes were compared to a weight-matched reference group (WEIGHT-REF, n = 8). Pro-atrial natriuretic peptide and cardiac troponin-T were measured weekly. Plasma pro-atrial natriuretic peptide decreased in both MAIZE and AGE-REF during the first 3 weeks but increased markedly in MAIZE relative to AGE-REF during week 5–7 (p≤0.001). There was overall no difference in plasma cardiac troponin-T between groups. However, further analysis revealed that release of cardiac troponin-T in plasma was more frequent in AGE-REF compared with MAIZE (OR: 4.8; 95%CI: 1.2–19.7; p = 0.03). However, when release occurred, cardiac troponin-T concentration was 6.9-fold higher (95%CI: 3.0–15.9; p<0.001) in MAIZE compared to AGE-REF. At week 7, the mean body weight in MAIZE was lower than AGE-REF (8.3 vs 32.4 kg, p<0.001), whereas heart-weight relative to body-weight was similar across the three groups. The myocardial performance index was 86% higher in MAIZE vs AGE-REF (p<0.001) and 27% higher in MAIZE vs WEIGHT-REF (p = 0.025). Conclusions Malnutrition associates with cardiac dysfunction in a pediatric porcine model by increased myocardial performance index and pro-atrial natriuretic peptide and it associates with cardiac injury by elevated cardiac troponin-T. Clinical studies are needed to see if the same applies for children suffering from malnutrition. PMID:26473958

  4. Economic Considerations of Early Rule-In/Rule-Out Algorithms for The Diagnosis of Myocardial Infarction in The Emergency Department Using Cardiac Troponin and Glycemic Biomarkers.

    PubMed

    Shortt, Colleen; Xie, Feng; Whitlock, Richard; Ma, Jinhui; Clayton, Natasha; Sherbino, Jonathan; Hill, Stephen A; Pare, Guillaume; McQueen, Matthew; Mehta, Shamir R; Devereaux, P J; Worster, Andrew; Kavsak, Peter

    2017-02-01

    We have previously demonstrated the utility of a rule-in/rule-out strategy for myocardial infarction (MI) using glycemic biomarkers in combination with cardiac troponin in the emergency department (ED). Given that the cost of assessing patients with possible MI in the ED is increasing, we sought to compare the health services cost of our previously identified early rule-in/rule-out approaches for MI among patients who present to the ED with symptoms suggestive of acute coronary syndrome (ACS). We compared the cost differences between different rule-in/rule-out strategies for MI using presentation cardiac troponin I (cTnI), high-sensitivity cTnI (hs-cTnI), high-sensitivity cardiac troponin T (hs-cTnT), glucose, and/or hemoglobin A 1c (Hb A 1c ) in 1137 ED patients (7-day MI n = 133) as per our previously defined algorithms and compared them with the European Society of Cardiology (ESC) 0-h algorithm-cutoffs. Costs associated with each decision model were obtained from site-specific sources (length of stay) and provincial sources (Ontario Case Costing Initiative). Algorithms incorporating cardiac troponin and glucose for early rule-in/rule-out were the most cost effective and clinically safest methods (i.e., ≤1 MI missed) for early decision making, with hs-cTnI and glucose yielding lower costs compared to cTnI and glucose, despite the higher price for the hs-cTnI test. The addition of Hb A 1c to the algorithms increased the cost of these algorithms but did not miss any additional patients with MI. Applying the ESC 0-h algorithm-cutoffs for hs-cTnI and hs-cTnT were the most costly. Rule-in/rule-out algorithms incorporating presentation glucose with high-sensitivity cardiac troponin are the safest and most cost-effective options as compared to the ESC 0-h algorithm-cutoffs. © 2016 American Association for Clinical Chemistry.

  5. Inhaled Xenon Attenuates Myocardial Damage in Comatose Survivors of Out-of-Hospital Cardiac Arrest: The Xe-Hypotheca Trial.

    PubMed

    Arola, Olli; Saraste, Antti; Laitio, Ruut; Airaksinen, Juhani; Hynninen, Marja; Bäcklund, Minna; Ylikoski, Emmi; Wennervirta, Johanna; Pietilä, Mikko; Roine, Risto O; Harjola, Veli-Pekka; Niiranen, Jussi; Korpi, Kirsi; Varpula, Marjut; Scheinin, Harry; Maze, Mervyn; Vahlberg, Tero; Laitio, Timo

    2017-11-28

    The authors previously reported that inhaled xenon combined with hypothermia attenuates brain white matter injury in comatose survivors of out-of-hospital cardiac arrest (OHCA). A pre-defined secondary objective was to assess the effect of inhaled xenon on myocardial ischemic damage in the same study population. A total of 110 comatose patients who had experienced OHCA from a cardiac cause were randomized to receive either inhaled xenon (40% end-tidal concentration) combined with hypothermia (33°C) for 24 h (n = 55; xenon group) or hypothermia treatment alone (n = 55; control group). Troponin-T levels were measured at hospital admission, and at 24 h, 48 h, and 72 h post-cardiac arrest. All available cases were analyzed for troponin-T release. Troponin-T measurements were available from 54 xenon patients and 54 control patients. The baseline characteristics did not differ significantly between the groups. After adjustments for age, sex, study site, primary coronary percutaneous intervention (PCI), and norepinephrine dose, the mean ± SD post-arrival incremental change of the ln-transformed troponin-T at 72 h was 0.79 ± 1.54 in the xenon group and 1.56 ± 1.38 in the control group (adjusted mean difference -0.66; 95% confidence interval: -1.16 to -0.16; p = 0.01). The effect of xenon on the change in the troponin-T values did not differ in patients with or without PCI or in those with a diagnosis of ST-segment elevation myocardial infarction (group by PCI or ST-segment elevation myocardial infarction interaction effect; p = 0.86 and p = 0.71, respectively). Among comatose survivors of OHCA, in comparison with hypothermia alone, inhaled xenon combined with hypothermia suggested a less severe myocardial injury as demonstrated by the significantly reduced release of troponin-T. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Comparative Analysis of Mass Spectral Similarity Measures on Peak Alignment for Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry

    PubMed Central

    2013-01-01

    Peak alignment is a critical procedure in mass spectrometry-based biomarker discovery in metabolomics. One of peak alignment approaches to comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) data is peak matching-based alignment. A key to the peak matching-based alignment is the calculation of mass spectral similarity scores. Various mass spectral similarity measures have been developed mainly for compound identification, but the effect of these spectral similarity measures on the performance of peak matching-based alignment still remains unknown. Therefore, we selected five mass spectral similarity measures, cosine correlation, Pearson's correlation, Spearman's correlation, partial correlation, and part correlation, and examined their effects on peak alignment using two sets of experimental GC×GC-MS data. The results show that the spectral similarity measure does not affect the alignment accuracy significantly in analysis of data from less complex samples, while the partial correlation performs much better than other spectral similarity measures when analyzing experimental data acquired from complex biological samples. PMID:24151524

  7. Novel biomarkers in critical care: utility or futility?

    PubMed Central

    Ackland, Gareth L; Mythen, Michael G

    2007-01-01

    One of the holy grails of modern medicine, across a range of clinical sub-specialties, is establishing highly sensitive and specific biomarkers for various diseases. Significant success has been achieved in some of these clinical areas, most notably identifying high-sensitivity C-reactive peptide, troponin I/T and brain natriuretic peptide as significant prognosticators for both the acute outcome and the development of cardiovascular pathology. However, it is highly debatable whether this translates to complex, multi-system pathophysiological insults. Is critical care immune from the application of these novel biomarkers, given the numerous confounding factors interfering with their interpretation? PMID:18001503

  8. Myocardial injury after noncardiac surgery: a large, international, prospective cohort study establishing diagnostic criteria, characteristics, predictors, and 30-day outcomes.

    PubMed

    Botto, Fernando; Alonso-Coello, Pablo; Chan, Matthew T V; Villar, Juan Carlos; Xavier, Denis; Srinathan, Sadeesh; Guyatt, Gordon; Cruz, Patricia; Graham, Michelle; Wang, C Y; Berwanger, Otavio; Pearse, Rupert M; Biccard, Bruce M; Abraham, Valsa; Malaga, German; Hillis, Graham S; Rodseth, Reitze N; Cook, Deborah; Polanczyk, Carisi A; Szczeklik, Wojciech; Sessler, Daniel I; Sheth, Tej; Ackland, Gareth L; Leuwer, Martin; Garg, Amit X; Lemanach, Yannick; Pettit, Shirley; Heels-Ansdell, Diane; Luratibuse, Giovanna; Walsh, Michael; Sapsford, Robert; Schünemann, Holger J; Kurz, Andrea; Thomas, Sabu; Mrkobrada, Marko; Thabane, Lehana; Gerstein, Hertzel; Paniagua, Pilar; Nagele, Peter; Raina, Parminder; Yusuf, Salim; Devereaux, P J; Devereaux, P J; Sessler, Daniel I; Walsh, Michael; Guyatt, Gordon; McQueen, Matthew J; Bhandari, Mohit; Cook, Deborah; Bosch, Jackie; Buckley, Norman; Yusuf, Salim; Chow, Clara K; Hillis, Graham S; Halliwell, Richard; Li, Stephen; Lee, Vincent W; Mooney, John; Polanczyk, Carisi A; Furtado, Mariana V; Berwanger, Otavio; Suzumura, Erica; Santucci, Eliana; Leite, Katia; Santo, Jose Amalth do Espirirto; Jardim, Cesar A P; Cavalcanti, Alexandre Biasi; Guimaraes, Helio Penna; Jacka, Michael J; Graham, Michelle; McAlister, Finlay; McMurtry, Sean; Townsend, Derek; Pannu, Neesh; Bagshaw, Sean; Bessissow, Amal; Bhandari, Mohit; Duceppe, Emmanuelle; Eikelboom, John; Ganame, Javier; Hankinson, James; Hill, Stephen; Jolly, Sanjit; Lamy, Andre; Ling, Elizabeth; Magloire, Patrick; Pare, Guillaume; Reddy, Deven; Szalay, David; Tittley, Jacques; Weitz, Jeff; Whitlock, Richard; Darvish-Kazim, Saeed; Debeer, Justin; Kavsak, Peter; Kearon, Clive; Mizera, Richard; O'Donnell, Martin; McQueen, Matthew; Pinthus, Jehonathan; Ribas, Sebastian; Simunovic, Marko; Tandon, Vikas; Vanhelder, Tomas; Winemaker, Mitchell; Gerstein, Hertzel; McDonald, Sarah; O'Bryne, Paul; Patel, Ameen; Paul, James; Punthakee, Zubin; Raymer, Karen; Salehian, Omid; Spencer, Fred; Walter, Stephen; Worster, Andrew; Adili, Anthony; Clase, Catherine; Cook, Deborah; Crowther, Mark; Douketis, James; Gangji, Azim; Jackson, Paul; Lim, Wendy; Lovrics, Peter; Mazzadi, Sergio; Orovan, William; Rudkowski, Jill; Soth, Mark; Tiboni, Maria; Acedillo, Rey; Garg, Amit; Hildebrand, Ainslie; Lam, Ngan; Macneil, Danielle; Mrkobrada, Marko; Roshanov, Pavel S; Srinathan, Sadeesh K; Ramsey, Clare; John, Philip St; Thorlacius, Laurel; Siddiqui, Faisal S; Grocott, Hilary P; McKay, Andrew; Lee, Trevor W R; Amadeo, Ryan; Funk, Duane; McDonald, Heather; Zacharias, James; Villar, Juan Carlos; Cortés, Olga Lucía; Chaparro, Maria Stella; Vásquez, Skarlett; Castañeda, Alvaro; Ferreira, Silvia; Coriat, Pierre; Monneret, Denis; Goarin, Jean Pierre; Esteve, Cristina Ibanez; Royer, Catherine; Daas, Georges; Chan, Matthew T V; Choi, Gordon Y S; Gin, Tony; Lit, Lydia C W; Xavier, Denis; Sigamani, Alben; Faruqui, Atiya; Dhanpal, Radhika; Almeida, Smitha; Cherian, Joseph; Furruqh, Sultana; Abraham, Valsa; Afzal, Lalita; George, Preetha; Mala, Shaveta; Schünemann, Holger; Muti, Paola; Vizza, Enrico; Wang, C Y; Ong, G S Y; Mansor, Marzida; Tan, Alvin S B; Shariffuddin, Ina I; Vasanthan, V; Hashim, N H M; Undok, A Wahab; Ki, Ushananthini; Lai, Hou Yee; Ahmad, Wan Azman; Razack, Azad H A; Malaga, German; Valderrama-Victoria, Vanessa; Loza-Herrera, Javier D; De Los Angeles Lazo, Maria; Rotta-Rotta, Aida; Szczeklik, Wojciech; Sokolowska, Barbara; Musial, Jacek; Gorka, Jacek; Iwaszczuk, Pawel; Kozka, Mateusz; Chwala, Maciej; Raczek, Marcin; Mrowiecki, Tomasz; Kaczmarek, Bogusz; Biccard, Bruce; Cassimjee, Hussein; Gopalan, Dean; Kisten, Theroshnie; Mugabi, Aine; Naidoo, Prebashini; Naidoo, Rubeshan; Rodseth, Reitze; Skinner, David; Torborg, Alex; Paniagua, Pilar; Urrutia, Gerard; Maestre, Mari Luz; Santaló, Miquel; Gonzalez, Raúl; Font, Adrià; Martínez, Cecilia; Pelaez, Xavier; De Antonio, Marta; Villamor, Jose Marcial; García, Jesús Alvarez; Ferré, Maria José; Popova, Ekaterina; Alonso-Coello, Pablo; Garutti, Ignacio; Cruz, Patricia; Fernández, Carmen; Palencia, Maria; Díaz, Susana; Del Castillo, Teresa; Varela, Alberto; de Miguel, Angeles; Muñoz, Manuel; Piñeiro, Patricia; Cusati, Gabriel; Del Barrio, Maria; Membrillo, Maria José; Orozco, David; Reyes, Fidel; Sapsford, Robert J; Barth, Julian; Scott, Julian; Hall, Alistair; Howell, Simon; Lobley, Michaela; Woods, Janet; Howard, Susannah; Fletcher, Joanne; Dewhirst, Nikki; Williams, C; Rushton, A; Welters, I; Leuwer, M; Pearse, Rupert; Ackland, Gareth; Khan, Ahsun; Niebrzegowska, Edyta; Benton, Sally; Wragg, Andrew; Archbold, Andrew; Smith, Amanda; McAlees, Eleanor; Ramballi, Cheryl; Macdonald, Neil; Januszewska, Marta; Stephens, Robert; Reyes, Anna; Paredes, Laura Gallego; Sultan, Pervez; Cain, David; Whittle, John; Del Arroyo, Ana Gutierrez; Sessler, Daniel I; Kurz, Andrea; Sun, Zhuo; Finnegan, Patrick S; Egan, Cameron; Honar, Hooman; Shahinyan, Aram; Panjasawatwong, Krit; Fu, Alexander Y; Wang, Sihe; Reineks, Edmunds; Nagele, Peter; Blood, Jane; Kalin, Megan; Gibson, David; Wildes, Troy

    2014-03-01

    Myocardial injury after noncardiac surgery (MINS) was defined as prognostically relevant myocardial injury due to ischemia that occurs during or within 30 days after noncardiac surgery. The study's four objectives were to determine the diagnostic criteria, characteristics, predictors, and 30-day outcomes of MINS. In this international, prospective cohort study of 15,065 patients aged 45 yr or older who underwent in-patient noncardiac surgery, troponin T was measured during the first 3 postoperative days. Patients with a troponin T level of 0.04 ng/ml or greater (elevated "abnormal" laboratory threshold) were assessed for ischemic features (i.e., ischemic symptoms and electrocardiography findings). Patients adjudicated as having a nonischemic troponin elevation (e.g., sepsis) were excluded. To establish diagnostic criteria for MINS, the authors used Cox regression analyses in which the dependent variable was 30-day mortality (260 deaths) and independent variables included preoperative variables, perioperative complications, and potential MINS diagnostic criteria. An elevated troponin after noncardiac surgery, irrespective of the presence of an ischemic feature, independently predicted 30-day mortality. Therefore, the authors' diagnostic criterion for MINS was a peak troponin T level of 0.03 ng/ml or greater judged due to myocardial ischemia. MINS was an independent predictor of 30-day mortality (adjusted hazard ratio, 3.87; 95% CI, 2.96-5.08) and had the highest population-attributable risk (34.0%, 95% CI, 26.6-41.5) of the perioperative complications. Twelve hundred patients (8.0%) suffered MINS, and 58.2% of these patients would not have fulfilled the universal definition of myocardial infarction. Only 15.8% of patients with MINS experienced an ischemic symptom. Among adults undergoing noncardiac surgery, MINS is common and associated with substantial mortality.

  9. Influence of Nitrous Oxide Anesthesia, B-Vitamins, and MTHFR gene polymorphisms on Perioperative Cardiac Events: The Vitamins in Nitrous Oxide (VINO) Randomized Trial

    PubMed Central

    Nagele, Peter; Brown, Frank; Francis, Amber; Scott, Mitchell G.; Gage, Brian F.; Miller, J. Philip

    2013-01-01

    Background Nitrous oxide causes an acute increase in plasma homocysteine that is more pronounced in patients with the MTHFR C677T or A1298C gene variant. In this randomized controlled trial we sought to determine if patients carrying the MTHFR C677T or A1298C variant had a higher risk for perioperative cardiac events after nitrous oxide anesthesia and if this risk could be mitigated by B-vitamins. Methods We randomized adult patients with cardiac risk factors undergoing noncardiac surgery to receive nitrous oxide plus intravenous B-vitamins before and after surgery or to nitrous oxide and placebo. Serial cardiac biomarkers and 12-lead electrocardiograms were obtained. The primary study endpoint was the incidence of myocardial injury, as defined by cardiac troponin I elevation within the first 72 hours after surgery. Results A total of 500 patients completed the trial. Patients who were homozygous for either MTHFR C677T or A1298C gene variant (n= 98; 19.6%) had no increased rate of postoperative cardiac troponin I elevation compared to wild-type and heterozygous patients (11.2% vs. 14.0%; relative risk 0.96, 95% CI 0.85 to 1.07, p=0.48). B-vitamins blunted the rise in homocysteine, but had no effect on cardiac troponin I elevation compared to patients receiving placebo (13.2% vs. 13.6%; relative risk 1.02, 95% CI 0.78 to 1.32, p=0.91). Conclusions Neither MTHFR C677T and A1298C gene variant nor acute homocysteine increase are associated with perioperative cardiac troponin elevation after nitrousoxide anesthesia. B-vitamins blunt nitrous oxide-induced homocysteine increase but have no effect on cardiac troponin elevation. PMID:23856660

  10. Cardiac Troponin Is a Predictor of Septic Shock Mortality in Cancer Patients in an Emergency Department: A Retrospective Cohort Study.

    PubMed

    Yang, Zhi; Qdaisat, Aiham; Hu, Zhihuang; Wagar, Elizabeth A; Reyes-Gibby, Cielito; Meng, Qing H; Yeung, Sai-Ching J

    2016-01-01

    Septic shock may be associated with myocardial damage; however, the prognostic value of cardiac enzymes in cancer patients with septic shock is unknown. In this study, we evaluated the prognostic significance of cardiac enzymes in combination with established prognostic factors in predicting the 7-day mortality rate of patients with septic shock, and we constructed a new scoring system, Septic Oncologic Patients in Emergency Department (SOPED), which includes cardiac enzymes, to predict 7-day mortality rates. We performed a retrospective cohort study of 375 adult cancer patients with septic shock who visited the emergency department of a comprehensive cancer center between 01/01/2004 and 12/31/2013. The 7-day and 28-day mortality rates were 19.7% and 37.6%, respectively. The creatine kinase myocardial band fraction and troponin-I were significantly higher in patients who died in ≤7 days and ≤28 days than in those who did not. In Cox regression models, troponin-I >0.05 ng/mL plus Predisposition, Infection, Response, and Organ Failure (PIRO2011) or Mortality in Emergency Department Sepsis (MEDS) score was a significant predictor of survival for ≤7 days. With our new SOPED scoring system, the receiver operating characteristic area under the curve was 0.836, higher than those for PIRO2011 and MEDS. Troponin-I >0.05 ng/mL was an important predictor of short-term mortality (≤7 days). The SOPED scoring system, which incorporated troponin-I, was more prognostically accurate than were other scores for 7-day mortality. Large multicenter studies are needed to verify our results and prospectively validate the prognostic performance of the SOPED score.

  11. Dynamic Equilibrium of Cardiac Troponin C's Hydrophobic Cleft and Its Modulation by Ca2+ Sensitizers and a Ca2+ Sensitivity Blunting Phosphomimic, cTnT(T204E).

    PubMed

    Schlecht, William; Dong, Wen-Ji

    2017-10-18

    Several studies have suggested that conformational dynamics are important in the regulation of thin filament activation in cardiac troponin C (cTnC); however, little direct evidence has been offered to support these claims. In this study, a dye homodimerization approach is developed and implemented that allows the determination of the dynamic equilibrium between open and closed conformations in cTnC's hydrophobic cleft. Modulation of this equilibrium by Ca 2+ , cardiac troponin I (cTnI), cardiac troponin T (cTnT), Ca 2+ -sensitizers, and a Ca 2+ -desensitizing phosphomimic of cTnT (cTnT(T204E) is characterized. Isolated cTnC contained a small open conformation population in the absence of Ca 2+ that increased significantly upon the addition of saturating levels of Ca 2+ . This suggests that the Ca 2+ -induced activation of thin filament arises from an increase in the probability of hydrophobic cleft opening. The inclusion of cTnI increased the population of open cTnC, and the inclusion of cTnT had the opposite effect. Samples containing Ca 2+ -desensitizing cTnT(T204E) showed a slight but insignificant decrease in open conformation probability compared to samples with cardiac troponin T, wild type [cTnT(wt)], while Ca 2+ sensitizer treated samples generally increased open conformation probability. These findings show that an equilibrium between the open and closed conformations of cTnC's hydrophobic cleft play a significant role in tuning the Ca 2+ sensitivity of the heart.

  12. Prevalence of Positive Troponin and Echocardiogram Findings and Association With Mortality in Acute Ischemic Stroke.

    PubMed

    Wrigley, Peter; Khoury, Jane; Eckerle, Bryan; Alwell, Kathleen; Moomaw, Charles J; Woo, Daniel; Flaherty, Mathew L; De Los Rios la Rosa, Felipe; Mackey, Jason; Adeoye, Opeolu; Martini, Sharyl; Ferioli, Simona; Kissela, Brett M; Kleindorfer, Dawn O

    2017-05-01

    Acute ischemic stroke (AIS) patients may have raised serum cardiac troponin levels on admission, although it is unclear what prognostic implications this has, and whether elevated levels are associated with cardiac causes of stroke or structural cardiac disease as seen on echocardiogram. We investigated the positivity of cardiac troponin and echocardiogram testing within a large biracial AIS population and any association with poststroke mortality. Within a catchment area of 1.3 million, we screened emergency department admissions from 2010 using International Classification of Diseases, Ninth Edition , discharge codes 430 to 436 and ascertained all physician-confirmed AIS cases by retrospective chart review. Hypertroponinemia was defined as elevation in cardiac troponin above the standard 99th percentile. Multiple logistic regression was performed, controlling for stroke severity, history of cardiac disease, and all other stroke risk factors. Of 1999 AIS cases, 1706 (85.3%) had a cardiac troponin drawn and 1590 (79.5%) had echocardiograms. Hypertroponinemia occurred in 353 of 1706 (20.7%) and 160 of 1590 (10.1%) had echocardiogram findings of interest. Among 1377 who had both tests performed, hypertroponinemia was independently associated with echocardiogram findings (odds ratio, 2.9; 95% confidence interval, 2-4.2). When concurrent myocardial infarctions (3.5%) were excluded, hypertroponinemia was also associated with increased mortality at 1 year (35%; odds ratio, 3.45; 95% confidence interval, 2.1-5.6) and 3 years (60%; odds ratio, 2.91; 95% confidence interval, 2.06-4.11). Hypertroponinemia in the context of AIS without concurrent myocardial infarction was associated with structural cardiac disease and long-term mortality. Prospective studies are needed to determine whether further cardiac evaluation might improve the long-term mortality rates seen in this group. © 2017 American Heart Association, Inc.

  13. Left ventricular diastolic dysfunction without left ventricular hypertrophy in obese children and adolescents: a Tissue Doppler Imaging and Cardiac Troponin I Study.

    PubMed

    El Saiedi, Sonia A; Mira, Marwa F; Sharaf, Sahar A; Al Musaddar, Maysoun M; El Kaffas, Rania M H; AbdelMassih, Antoine F; Barsoum, Ihab H Y

    2018-01-01

    Obesity increases the risk for various cardiovascular problems. Increase in body mass index is often an independent risk factor for the development of elevated blood pressure and clustering of various cardiovascular risk factors. To determine early markers of left ventricular affection in obese patients before the appearance of left ventricular hypertrophy. In this cross-sectional study, we evaluated 42 obese patients and 30 healthy controls. Their ages ranged from 6 to 19 years. Studied children were subjected to anthropometric, lipid profile, and serum Troponin I level measurements. Echocardiographic evaluation performed to assess the left ventricle included left ventricular dimension measurement using motion-mode echocardiography, based on which patients with left ventricular hypertrophy (10 patients) were eliminated, as well as conventional and tissue Doppler imaging. Tissue Doppler findings in the study groups showed that the ratio of transmitral early diastolic filling velocity to septal peak early diastolic myocardial velocity (E/e') was significantly higher in cases compared with controls [6.9±1.4 versus 9.0±1.6, p (Pearson's coefficient)=0.001, respectively]. The level of cardiac troponin I was significantly higher in cases compared with controls [0.14±0.39 ng/ml versus 0.01±0.01 ng/ml, p (Pearson's coefficient)=0.047, respectively] and there was a significant correlation between troponin I and transmitral early diastolic filling velocity to septal peak early diastolic myocardial velocity ratio (E/e') [R (correlation coefficient)=0.6]. Tissue Doppler Imaging and Troponin I evaluation proved useful tools to detect early affection of the left ventricle in obese patients even in the absence of left ventricular hypertrophy.

  14. New myocardial infarction definition affects incidence, mortality, hospitalization rates and prognosis.

    PubMed

    Agüero, Fernando; Marrugat, Jaume; Elosua, Roberto; Sala, Joan; Masiá, Rafael; Ramos, Rafel; Grau, María

    2015-10-01

    To analyse differences in myocardial infarction incidence, mortality and hospitalization rates, 28-day case-fatality and two-year prognosis using two myocardial infarction case definitions: the classical World Health Organization definition (1994) and the European Society of Cardiology/American College of Cardiology definition (2000), which added cardiac troponin as a diagnostic biomarker. Population-based cohort of 4170 consecutive myocardial infarction patients aged 35-74 years from Girona (Spain) recruited between 2002 and 2009. Incidence, mortality rates standardized to the European population and 28-day case-fatality were calculated. To estimate the association between case definition and prognosis, Cox models were fitted. Use of the 2000 European Society of Cardiology/American College of Cardiology definition significantly increased myocardial infarction incidence per 100,000 population (238.3 vs. 274.5 in men and 54.1 vs. 69.7 in women). Applying this definition decreased the 28-day case-fatality rate from 26.9% to 23.4% in men, and from 31.0% to 24.1% in women. In the acute phase, patients diagnosed only by increased troponins were significantly less treated with thrombolysis (34.4% vs. 2.0%), angiotensin-converting enzyme inhibitors (71.7% vs. 65.0%) and percutaneous coronary intervention (41.1% vs. 31.7%). Case-fatality at 28 days was significantly better in cases diagnosed only by troponin increase (0.2 % vs. 9.7%), but two-year cardiovascular mortality was higher (7.5% vs. 3.7%). Inclusion of cardiac troponins in myocardial infarction diagnosis increased annual incidence and decreased case-fatality. Diagnosis based only on increased troponins was associated with worse outcome. This group of patients at high risk of death should receive aggressive secondary prevention therapy. © The European Society of Cardiology 2014.

  15. Usefulness of the troponin-ejection fraction product to differentiate stress cardiomyopathy from ST-segment elevation myocardial infarction.

    PubMed

    Nascimento, Francisco O; Yang, Solomon; Larrauri-Reyes, Maiteder; Pineda, Andres M; Cornielle, Vertilio; Santana, Orlando; Heimowitz, Todd B; Stone, Gregg W; Beohar, Nirat

    2014-02-01

    The presentation of stress cardiomyopathy (SC) with nonobstructive coronary artery disease mimics that of ST-segment elevation myocardial infarction (STEMI) due to coronary occlusion. No single parameter has been successful in differentiating the 2 entities. We thus sought to develop a noninvasive clinical tool to discriminate between these 2 conditions. We retrospectively reviewed 59 consecutive cases of SC at our institution from July 2005 through June 2011 and compared those with 60 consecutives cases of angiographically confirmed STEMI treated with primary percutaneous coronary intervention in the same period. All patients underwent acute echocardiography, and the peak troponin I level was determined. The troponin-ejection fraction product (TEFP) was derived by multiplying the peak troponin I level and the echocardiographically derived left ventricular ejection fraction. Comparing the SC and STEMI groups, the mean left ventricular ejection fraction at the time of presentation was 30 ± 9% versus 44 ± 11%, respectively (p <0.001), and the peak troponin I was 7.6 ± 18 versus 102.2 ± 110.3 ng/dl, respectively (p <0.001). The mean TEFP was thus 182 ± 380 and 4,088 ± 4,244 for the SC and STEMI groups, respectively (p <0.001). Receiver operating characteristic curve analysis showed that a TEFP value ≥250 had a sensitivity of 95%, a specificity of 87%, a negative predictive value of 94%, a positive predictive value of 88%, and an overall accuracy of 91% to differentiate a true STEMI from SC (C-statistic 0.91 ± 0.02, p <0.001). In conclusion, for patients not undergoing emergent angiography, the TEFP may be used with high accuracy to differentiate SC with nonobstructive coronary artery disease from true STEMI due to coronary occlusion. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. The cardiac troponins: uses in routine clinical practice. Experiences from GUSTO and other clinical trials.

    PubMed

    Stubbs, P

    1998-11-01

    Recent advances in pharmacological and mechanical approaches to acute coronary syndromes have led to rapid changes in the management of patients admitted with acute coronary syndromes. These changes have been mirrored by the appearance of newer highly specific biochemical markers of myocardial damage particularly the cardiac troponins. When new biochemical markers become available it is the responsibility of the clinical chemist to evaluate them critically in terms of sensitivity, specificity, efficiency and analyzer precision, in the rigid setting of quality control that laboratories practise, and to compare them with other markers. When the data are shown to Clinical Cardiologists with supporting statements such as 'useful management tool' and 'can be used for early diagnosis of Myocardial Infarction', a different set of questions may need to be answered. The 'So what?' response is most frequent and is the most important hurdle that these newer biochemical markers have to overcome to convince physicians to change their current practice. This presentation will review the results of studies that have examined the potential clinical usefulness of the cardiac troponins with respect to diagnosis and risk stratification of patients admitted with suspected acute coronary syndromes. Any troponin variable that survives the 'so what' question has one further major hurdle to overcome. This is the requirement to inform physicians what different therapeutic strategies they should follow if the variable is present. Available clinical trial evidence about differing management options for patients according to their troponin status will be reviewed and outline management algorithms will be presented. Many questions remain unanswered and these will be included at the time points where they may be relevant.

  17. Purification of cardiomyocytes from differentiating pluripotent stem cells using molecular beacons that target cardiomyocyte-specific mRNA.

    PubMed

    Ban, Kiwon; Wile, Brian; Kim, Sangsung; Park, Hun-Jun; Byun, Jaemin; Cho, Kyu-Won; Saafir, Talib; Song, Ming-Ke; Yu, Shan Ping; Wagner, Mary; Bao, Gang; Yoon, Young-Sup

    2013-10-22

    Although methods for generating cardiomyocytes from pluripotent stem cells have been reported, current methods produce heterogeneous mixtures of cardiomyocytes and noncardiomyocyte cells. Here, we report an entirely novel system in which pluripotent stem cell-derived cardiomyocytes are purified by cardiomyocyte-specific molecular beacons (MBs). MBs are nanoscale probes that emit a fluorescence signal when hybridized to target mRNAs. Five MBs targeting mRNAs of either cardiac troponin T or myosin heavy chain 6/7 were generated. Among 5 MBs, an MB that targeted myosin heavy chain 6/7 mRNA (MHC1-MB) identified up to 99% of HL-1 cardiomyocytes, a mouse cardiomyocyte cell line, but <3% of 4 noncardiomyocyte cell types in flow cytometry analysis, which indicates that MHC1-MB is specific for identifying cardiomyocytes. We delivered MHC1-MB into cardiomyogenically differentiated pluripotent stem cells through nucleofection. The detection rate of cardiomyocytes was similar to the percentages of cardiac troponin T- or cardiac troponin I-positive cardiomyocytes, which supports the specificity of MBs. Finally, MHC1-MB-positive cells were sorted by fluorescence-activated cell sorter from mouse and human pluripotent stem cell differentiating cultures, and ≈97% cells expressed cardiac troponin T or cardiac troponin I as determined by flow cytometry. These MB-based sorted cells maintained their cardiomyocyte characteristics, which was verified by spontaneous beating, electrophysiological studies, and expression of cardiac proteins. When transplanted in a myocardial infarction model, MB-based purified cardiomyocytes improved cardiac function and demonstrated significant engraftment for 4 weeks without forming tumors. We developed a novel cardiomyocyte selection system that allows production of highly purified cardiomyocytes. These purified cardiomyocytes and this system can be valuable for cell therapy and drug discovery.

  18. Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome.

    PubMed

    Angeletti, Silvia; De Cesaris, Marina; Hart, Jonathan George; Urbano, Michele; Vitali, Massimiliano Andrea; Fragliasso, Fulvio; Dicuonzo, Giordano

    2015-12-01

    Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT. © 2015 Society for Laboratory Automation and Screening.

  19. Evolution of EF-hand calcium-modulated proteins. IV. Exon shuffling did not determine the domain compositions of EF-hand proteins

    NASA Technical Reports Server (NTRS)

    Kretsinger, R. H.; Nakayama, S.

    1993-01-01

    In the previous three reports in this series we demonstrated that the EF-hand family of proteins evolved by a complex pattern of gene duplication, transposition, and splicing. The dendrograms based on exon sequences are nearly identical to those based on protein sequences for troponin C, the essential light chain myosin, the regulatory light chain, and calpain. This validates both the computational methods and the dendrograms for these subfamilies. The proposal of congruence for calmodulin, troponin C, essential light chain, and regulatory light chain was confirmed. There are, however, significant differences in the calmodulin dendrograms computed from DNA and from protein sequences. In this study we find that introns are distributed throughout the EF-hand domain and the interdomain regions. Further, dendrograms based on intron type and distribution bear little resemblance to those based on protein or on DNA sequences. We conclude that introns are inserted, and probably deleted, with relatively high frequency. Further, in the EF-hand family exons do not correspond to structural domains and exon shuffling played little if any role in the evolution of this widely distributed homolog family. Calmodulin has had a turbulent evolution. Its dendrograms based on protein sequence, exon sequence, 3'-tail sequence, intron sequences, and intron positions all show significant differences.

  20. Mitochondrial events responsible for morphine's cardioprotection against ischemia/reperfusion injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Haiyan; Department of Pharmacology, Tianjin Medical University, Tianjin 300070; Huh, Jin

    Morphine may induce cardioprotection by targeting mitochondria, but little is known about the exact mitochondrial events that mediate morphine's protection. We aimed to address the role of the mitochondrial Src tyrosine kinase in morphine's protection. Isolated rat hearts were subjected to 30 min ischemia and 2 h of reperfusion. Morphine was given before the onset of ischemia. Infarct size and troponin I release were measured to evaluate cardiac injury. Oxidative stress was evaluated by measuring mitochondrial protein carbonylation and mitochondrial ROS generation. HL-1 cells were subjected to simulated ischemia/reperfusion and LDH release and mitochondrial membrane potential (ΔΨm) were measured. Morphinemore » reduced infarct size as well as cardiac troponin I release which were aborted by the selective Src tyrosine kinase inhibitors PP2 and Src-I1. Morphine also attenuated LDH release and prevented a loss of ΔΨm at reperfusion in a Src tyrosine kinase dependent manner in HL-1 cells. However, morphine failed to reduce LDH release in HL-1 cells transfected with Src siRNA. Morphine increased mitochondrial Src phosphorylation at reperfusion and this was abrogated by PP2. Morphine attenuated mitochondrial protein carbonylation and mitochondrial superoxide generation at reperfusion through Src tyrosine kinase. The inhibitory effect of morphine on the mitochondrial complex I activity was reversed by PP2. These data suggest that morphine induces cardioprotection by preventing mitochondrial oxidative stress through mitochondrial Src tyrosine kinase. Inhibition of mitochondrial complex I at reperfusion by Src tyrosine kinase may account for the prevention of mitochondrial oxidative stress by morphine. - Highlights: • Morphine induced mito-Src phosphorylation and reduced infarct size in rat hearts. • Morphine failed to reduce I/R-induced LDH release in Src-silencing HL-1 cells. • Morphine prevented mitochondria damage caused by I/R through Src. • Morphine reduced mitochondrial ROS generation by inhibiting complex I via Src.« less

  1. Treat the patient not the blood test: the implications of an increase in cardiac troponin after prolonged endurance exercise

    PubMed Central

    Whyte, G; Stephens, N; Senior, R; George, K; Shave, R; Wilson, M; Sharma, S

    2007-01-01

    Collapse after prolonged endurance exercise is common and usually benign. This case study reports a triathlete who suffered a vaso‐vagal associated collapsed after exercise. Misdiagnosis of myocardial injury in the presence of elevated cardiac troponins and ECG anomalies led to inappropriate management and highlights the difficulty in treating the collapsed athlete following arduous exercise. PMID:17261549

  2. Treat the patient not the blood test: the implications of an increase in cardiac troponin after prolonged endurance exercise

    PubMed Central

    Whyte, Gregory; Whyte, Gregory; Stephens, Nigel; Senior, Roxy; George, Keith; Shave, Robert; Wilson, Mathew; Sharma, Sanjay

    2009-01-01

    Collapse after prolonged endurance exercise is common and usually benign. This case study reports a triathlete who suffered a vaso-vagal associated collapsed after exercise. Misdiagnosis of myocardial injury in the presence of elevated cardiac troponins and ECG anomalies led to inappropriate management and highlights the difficulty in treating the collapsed athlete following arduous exercise. PMID:21686646

  3. Recent Advances in Point-of-Care Diagnostics for Cardiac Markers

    PubMed Central

    2014-01-01

    National and international cardiology guidelines have recommended a 1-hour turnaround time for reporting results of cardiac troponin to emergency department personnel, measured from the time of blood collection to reporting. Use of point-of-care testing (POCT) can reduce turnaround times for cardiac markers, but current devices are not as precise or sensitive as central laboratory assays. The gap is growing as manufacturers of mainframe immunoassay instruments have or will release troponin assays that are even higher than those currently available. These assays have analytical sensitivity that enables detection of nearly 100% of all healthy subjects which is not possible for current POCT assays. Use of high sensitivity troponin results in a lower value for the 99th percentile of a healthy population. Clinically, this enables for the detection of more cases of myocardial injury. In order to compete analytically, next generation POCT assays will to make technologic advancements, such as the use of microfluidic to better control sample delivery, nanoparticles or nanotubes to increase the surface-to-volume ratios for analytes and antibodies, and novel detection schemes such as chemiluminescence and electrochemical detectors to enhance analytical sensitivity. Multi-marker analysis using POCT is also on the horizon for tests that complement cardiac troponin. PMID:27683464

  4. Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers.

    PubMed

    Fathil, M F M; Md Arshad, M K; Gopinath, Subash C B; Hashim, U; Adzhri, R; Ayub, R M; Ruslinda, A R; Nuzaihan M N, M; Azman, A H; Zaki, M; Tang, Thean-Hock

    2015-08-15

    Acute myocardial infarction or myocardial infarction (MI) is a major health problem, due to diminished flow of blood to the heart, leads to higher rates of mortality and morbidity. Data from World Health Organization (WHO) accounted 30% of global death annually and expected more than 23 million die annually by 2030. This fatal effects trigger the need of appropriate biomarkers for early diagnosis, thus countermeasure can be taken. At the moment, the most specific markers for cardiac injury are cardiac troponin I (cTnI) and cardiac troponin T (cTnT) which have been considered as 'gold standard'. Due to higher specificity, determination of the level of cardiac troponins became a predominant indicator for MI. Several ways of diagnostics have been formulated, which include enzyme-linked immunosorbent assay, chemiluminescent, fluoro-immunoassays, electrical detections, surface plasmon resonance, and colorimetric protein assay. This review represents and elucidates the strategies, methods and detection levels involved in these diagnostics on cardiac superior biomarkers. The advancement, sensitivity, and limitations of each method are also discussed. In addition, it concludes with a discussion on the point-of care (POC) assay for a fast, accurate and ability of handling small sample measurement of cardiac biomarker. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. RF Jitter Modulation Alignment Sensing

    NASA Astrophysics Data System (ADS)

    Ortega, L. F.; Fulda, P.; Diaz-Ortiz, M.; Perez Sanchez, G.; Ciani, G.; Voss, D.; Mueller, G.; Tanner, D. B.

    2017-01-01

    We will present the numerical and experimental results of a new alignment sensing scheme which can reduce the complexity of alignment sensing systems currently used, while maintaining the same shot noise limited sensitivity. This scheme relies on the ability of electro-optic beam deflectors to create angular modulation sidebands in radio frequency, and needs only a single-element photodiode and IQ demodulation to generate error signals for tilt and translation degrees of freedom in one dimension. It distances itself from current techniques by eliminating the need for beam centering servo systems, quadrant photodetectors and Gouy phase telescopes. RF Jitter alignment sensing can be used to reduce the complexity in the alignment systems of many laser optical experiments, including LIGO and the ALPS experiment.

  6. EF-hand proteins and the regulation of actin-myosin interaction in the eutardigrade Hypsibius klebelsbergi (tardigrada).

    PubMed

    Prasath, Thiruketheeswaran; Greven, Hartmut; D'Haese, Jochen

    2012-06-01

    Many tardigrade species resist harsh environmental conditions by entering anhydrobiosis or cryobiosis. Desiccation as well as freeze resistance probably leads to changes of the ionic balance that includes the intracellular calcium concentration. In order to search for protein modifications affecting the calcium homoeostasis, we studied the regulatory system controlling actin-myosin interaction of the eutardigrade Hypsibius klebelsbergi and identified full-length cDNA clones for troponin C (TnC, 824 bp), calmodulin (CaM, 1,407 bp), essential myosin light chain (eMLC, 1,015 bp), and regulatory myosin light chain (rMLC, 984 bp) from a cDNA library. All four proteins belong to the EF-hand superfamily typified by a calcium coordinating helix-loop-helix motif. Further, we cloned and obtained recombinant TnC and both MLCs. CaM and TnC revealed four and two potential calcium-binding domains, respectively. Gel mobility shift assays demonstrated calcium-induced conformational transition of TnC. From both MLCs, only the rMLC showed one potential N-terminal EF-hand domain. Additionally, sequence properties suggest phosphorylation of this myosin light chain. Based on our results, we suggest a dual-regulated system at least in somatic muscles for tardigrades with a calcium-dependent tropomyosin-troponin complex bound to the actin filaments and a phosphorylation of the rMLC turning on and off both actin and myosin. Our results indicate no special modifications of the molecular structure and function of the EF-hand proteins in tardigrades. Phylogenetic trees of 131 TnCs, 96 rMLCs, and 62 eMLCs indicate affinities to Ecdysozoa, but also to some other taxa suggesting that our results reflect the complex evolution of these proteins rather than phylogenetic relationships. © 2012 WILEY PERIODICALS, INC.

  7. Epicardial fat thickness in stable coronary artery disease: its relationship with high-sensitive cardiac troponin T and N-terminal pro-brain natriuretic peptide.

    PubMed

    Börekçi, Abdurrezzak; Gür, Mustafa; Özaltun, Betül; Baykan, Ahmet Oytun; Harbalioğlu, Hazar; Seker, Taner; Sen, Ömer; Acele, Armağan; Gözükara, Mehmet Yavuz; Kuloğlu, Osman; Koç, Mevlüt; Çayli, Murat

    2014-12-01

    Epicardial adipose tissue is related to coronary atherosclerosis, left ventricle hypertrophy, myocardial dysfunction, cardiomyopathy, and inflammation, which produces a variety of cytokines that influence key pathogenic mechanisms of atherogenesis. The main goal of this study is to examine the relationship between epicardial fat thickness (EFT) and cardiovascular risk markers as well as the complexity of coronary artery disease (CAD) in patients with stable CAD. We prospectively included 439 stable CAD patients undergoing coronary angiography in the present study (mean age: 62.2±10.7 years). Patients were divided into two groups (EFTlow and EFThigh groups) according to their median EFT values. EFT was evaluated by two-dimensional echocardiography before angiography. The SYNTAX score was calculated in all patients. N-terminal pro-brain natriuretic peptide (NT-proBNP), high-sensitive C-reactive protein (hs-CRP), high-sensitive cardiac troponin T (hs-cTnT), uric acid, and other biochemical markers were also measured. Age, SYNTAX score, frequencies of diabetes, hyperlipidemia, and hypertension, NT-proBNP, hs-CRP, hs-cTnT, and uric acid levels were higher in EFThigh group compared with the EFTlow group (P<0.05 for all). EFT was associated independently with age (β=-0.102, P=0.001), diabetes (β=-0.083, P=0.011), SYNTAX score (β=0.352, P<0.001), hs-CRP level (β=0.217, P<0.001), hs-cTnT level (β=0.197, P<0.001), and NT-proBNP level (β=0.300, P<0.001) in multivariate analysis. EFT obtained by echocardiograpy may not only be an easy tool but also an important tool for early detection of increased cardiac risk as well as the extent and complexity of CAD in patients with stable CAD.

  8. SPARSE: quadratic time simultaneous alignment and folding of RNAs without sequence-based heuristics.

    PubMed

    Will, Sebastian; Otto, Christina; Miladi, Milad; Möhl, Mathias; Backofen, Rolf

    2015-08-01

    RNA-Seq experiments have revealed a multitude of novel ncRNAs. The gold standard for their analysis based on simultaneous alignment and folding suffers from extreme time complexity of [Formula: see text]. Subsequently, numerous faster 'Sankoff-style' approaches have been suggested. Commonly, the performance of such methods relies on sequence-based heuristics that restrict the search space to optimal or near-optimal sequence alignments; however, the accuracy of sequence-based methods breaks down for RNAs with sequence identities below 60%. Alignment approaches like LocARNA that do not require sequence-based heuristics, have been limited to high complexity ([Formula: see text] quartic time). Breaking this barrier, we introduce the novel Sankoff-style algorithm 'sparsified prediction and alignment of RNAs based on their structure ensembles (SPARSE)', which runs in quadratic time without sequence-based heuristics. To achieve this low complexity, on par with sequence alignment algorithms, SPARSE features strong sparsification based on structural properties of the RNA ensembles. Following PMcomp, SPARSE gains further speed-up from lightweight energy computation. Although all existing lightweight Sankoff-style methods restrict Sankoff's original model by disallowing loop deletions and insertions, SPARSE transfers the Sankoff algorithm to the lightweight energy model completely for the first time. Compared with LocARNA, SPARSE achieves similar alignment and better folding quality in significantly less time (speedup: 3.7). At similar run-time, it aligns low sequence identity instances substantially more accurate than RAF, which uses sequence-based heuristics. © The Author 2015. Published by Oxford University Press.

  9. Role of Symmetry in the Mirror-Image Confusions of Preschoolers.

    ERIC Educational Resources Information Center

    Vogel, Juliet M.; Loughlin, Kathleen A.

    1978-01-01

    Preschool children copied peg locations with standardized comparison pegboards aligned horizontally and diagonally and with three levels of pegboard complexity. Error patterns varied with type of alignment and display complexity. Results failed to support Bryant's hypothesis that mirror image confusions are no more frequent than other in-line…

  10. NT-ProBNP and Troponin T and Risk of Rapid Kidney Function Decline and Incident CKD in Elderly Adults

    PubMed Central

    Katz, Ronit; Dalrymple, Lorien; de Boer, Ian; DeFilippi, Christopher; Kestenbaum, Bryan; Park, Meyeon; Sarnak, Mark; Seliger, Stephen; Shlipak, Michael

    2015-01-01

    Background and objectives Elevations in N-terminal pro–B-type natriuretic peptide and high-sensitivity troponin T are associated with poor cardiovascular outcomes. Whether elevations in these cardiac biomarkers are associated with decline in kidney function was evaluated. Design, setting, participants, & measurements N-terminal pro–B-type natriuretic peptide and troponin T were measured at baseline in 3752 participants free of heart failure in the Cardiovascular Health Study. eGFR was determined from the Chronic Kidney Disease Epidemiology Collaboration equation using serum cystatin C. Rapid decline in kidney function was defined as decline in serum cystatin C eGFR≥30%, and incident CKD was defined as the onset of serum cystatin C eGFR<60 among those without CKD at baseline (n=2786). Cox regression models were used to examine the associations of each biomarker with kidney function decline adjusting for demographics, baseline serum cystatin C eGFR, diabetes, and other CKD risk factors. Results In total, 503 participants had rapid decline in serum cystatin C eGFR over a mean follow-up time of 6.41 (1.81) years, and 685 participants developed incident CKD over a mean follow-up time of 6.41 (1.74) years. Participants in the highest quartile of N-terminal pro–B-type natriuretic peptide (>237 pg/ml) had an 67% higher risk of rapid decline and 38% higher adjusted risk of incident CKD compared with participants in the lowest quartile (adjusted hazard ratio for serum cystatin C eGFR rapid decline, 1.67; 95% confidence interval, 1.25 to 2.23; hazard ratio for incident CKD, 1.38; 95% confidence interval, 1.08 to 1.76). Participants in the highest category of troponin T (>10.58 pg/ml) had 80% greater risk of rapid decline compared with participants in the lowest category (adjusted hazard ratio, 1.80; 95% confidence interval, 1.35 to 2.40). The association of troponin T with incident CKD was not statistically significant (hazard ratio, 1.17; 95% confidence interval, 0.92 to 1.50). Conclusions Elevated N-terminal pro–B-type natriuretic peptide and troponin T are associated with rapid decline of kidney function and incident CKD. Additional studies are needed to evaluate the mechanisms that may explain this association. PMID:25605700

  11. Cardiovascular risk stratification in hemodialysis patients in the era of highly sensitive troponins: should we choose between hs-troponin I and hs-troponin T?

    PubMed

    Bargnoux, Anne-Sophie; Kuster, Nils; Patrier, Laure; Dupuy, Anne-Marie; Tachon, Gaelle; Maurice, Francois; Badaoui, Bouchra; Chalabi, Lotfi; Badiou, Stéphanie; Deleuze, Sebastien; Leray-Moragues, Hélène; Morena, Marion; Canaud, Bernard; Cristol, Jean-Paul

    2016-04-01

    New highly sensitive (hs) assays have challenged the interpretation of cardiac troponins (cTn). The present study was designed to evaluate simultaneously conventional cTnT and cTnI together with their corresponding highly sensitive determinations in stable hemodialysis (HD) patients. Ability of cTn to stratify HD patient risk was assessed. A total of 224 stable HD patients was included in this observational study. cTnT and hs-cTnT were measured using Roche cTnT/hs-cTnT assays based on a Cobas e601® analyzer. cTnI and hs-cTnI were measured using Beckman AccuTnI/hs-TnI IUO assays on Access II system. Patients were followed up prospectively during 9 years. Relationship between cTn level and mortality was assessed through Cox survival analysis. The median cTnT and cTnI concentrations were 38.5 ng/L (IQR, 18.8-76) and 10 ng/L (IQR, 10-20), respectively. The median hs-cTnT and hs-cTnI concentrations were 62.5 ng/L (IQR, 38.8-96.3) and 13.9 ng/L (IQR, 8.4-23.6), respectively. The prevalence of values above the 99th percentile was significantly more marked with cTnT (85.3 and 97.8% for conventional and hs cTnT, respectively) than with cTnI (7.6 and 67.4% for conventional and hs cTnI, respectively). During the follow-up, 167 patients died, mainly from cardiac cause (n=77). The optimized cut-off values, determined by bootstrap method, predicting mortality were 38, 69, 20 and 11 ng/L for cTnT, hs-cTnT, cTnI and hs-cTnI, respectively. After full adjustment, elevated plasma concentrations of all troponin were significant predictors of mortality. A large proportion of patients free of acute coronary syndrome (ACS) has hs-cTn I or T higher than the 99th percentile which could be seen as a limiting factor for ACS screening. However, all generation and type of troponin assays could be reliable indicators of prognosis risk in HD patients.

  12. Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry.

    PubMed

    Vanhaebost, Jessica; Ducrot, Kewin; de Froidmont, Sébastien; Scarpelli, Maria Pia; Egger, Coraline; Baumann, Pia; Schmit, Gregory; Grabherr, Silke; Palmiere, Cristian

    2017-02-01

    The aim of this study was to assess whether the identification of pathological myocardial enhancement at multiphase postmortem computed tomography angiography was correlated with increased levels of troponin T and I in postmortem serum from femoral blood as well as morphological findings of myocardial ischemia. We further aimed to investigate whether autopsy cases characterized by increased troponin T and I concentrations as well as morphological findings of myocardial ischemia were also characterized by pathological myocardial enhancement at multiphase postmortem computed tomography angiography. Two different approaches were used. In one, 40 forensic autopsy cases that had pathological enhancement of the myocardium (mean Hounsfield units ≥95) observed at postmortem angiography were retrospectively selected. In the second approach, 40 forensic autopsy cases that had a cause of death attributed to acute myocardial ischemia were retrospectively selected. The preliminary results seem to indicate that the identification of a pathological enhancement of the myocardium at postmortem angiography is associated with the presence of increased levels of cardiac troponins in postmortem serum and morphological findings of ischemia. Analogously, a pathological enhancement of the myocardium at postmortem angiography can be retrospectively found in the great majority of autopsy cases characterized by increased cardiac troponin levels in postmortem serum and morphological findings of myocardial ischemia. Multiphase postmortem computed tomography angiography is a useful tool in the postmortem setting for investigating ischemically damaged myocardium.

  13. Polymer microfiber meshes facilitate cardiac differentiation of c-kit{sup +} human cardiac stem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kan, Lijuan; Thayer, Patrick; Fan, Huimin

    Electrospun microfiber meshes have been shown to support the proliferation and differentiation of many types of stem cells, but the phenotypic fate of c-kit{sup +} human cardiac stem cells (hCSCs) have not been explored. To this end, we utilized thin (~5 µm) elastomeric meshes consisting of aligned 1.7 µm diameter poly (ester-urethane urea) microfibers as substrates to examine their effect on hCSC viability, morphology, proliferation, and differentiation relative to cells cultured on tissue culture polystyrene (TCPS). The results showed that cells on microfiber meshes displayed an elongated morphology aligned in the direction of fiber orientation, lower proliferation rates, but increasedmore » expressions of genes and proteins majorly associated with cardiomyocyte phenotype. The early (NK2 homeobox 5, Nkx2.5) and late (cardiac troponin I, cTnI) cardiomyocyte genes were significantly increased on meshes (Nkx=2.5 56.2±13.0, cTnl=2.9±0.56,) over TCPS (Nkx2.5=4.2±0.9, cTnl=1.6±0.5, n=9, p<0.05 for both groups) after differentiation. In contrast, expressions of smooth muscle markers, Gata6 and myosin heavy chain (SM-MHC), were decreased on meshes. Immunocytochemical analysis with cardiac antibody exhibited the similar pattern of above cardiac differentiation. We conclude that aligned microfiber meshes are suitable for guiding cardiac differentiation of hCSCs and may facilitate stem cell-based therapies for treatment of cardiac diseases. - Highlights: • First study to characterize c-kit{sup +} human cardiac stem cells on microfiber meshes. • Microfiber meshes seem reducing cell proliferation, but no effect on cell viability. • Microfiber meshes facilitate the elongation of human cardiac stem cells in culture. • Cardiac but not smooth muscle differentiation were enhanced on microfiber meshes. • Microfiber meshes may be used as cardiac patches in cell-based cardiac therapy.« less

  14. Reducing beam shaper alignment complexity: diagnostic techniques for alignment and tuning

    NASA Astrophysics Data System (ADS)

    Lizotte, Todd E.

    2011-10-01

    Safe and efficient optical alignment is a critical requirement for industrial laser systems used in a high volume manufacturing environment. Of specific interest is the development of techniques to align beam shaping optics within a beam line; having the ability to instantly verify by a qualitative means that each element is in its proper position as the beam shaper module is being aligned. There is a need to reduce these types of alignment techniques down to a level where even a newbie to optical alignment will be able to complete the task. Couple this alignment need with the fact that most laser system manufacturers ship their products worldwide and the introduction of a new set of variables including cultural and language barriers, makes this a top priority for manufacturers. Tools and methodologies for alignment of complex optical systems need to be able to cross these barriers to ensure the highest degree of up time and reduce the cost of maintenance on the production floor. Customers worldwide, who purchase production laser equipment, understand that the majority of costs to a manufacturing facility is spent on system maintenance and is typically the largest single controllable expenditure in a production plant. This desire to reduce costs is driving the trend these days towards predictive and proactive, not reactive maintenance of laser based optical beam delivery systems [10]. With proper diagnostic tools, laser system developers can develop proactive approaches to reduce system down time, safe guard operational performance and reduce premature or catastrophic optics failures. Obviously analytical data will provide quantifiable performance standards which are more precise than qualitative standards, but each have a role in determining overall optical system performance [10]. This paper will discuss the use of film and fluorescent mirror devices as diagnostic tools for beam shaper module alignment off line or in-situ. The paper will also provide an overview methodology showing how it is possible to reduce complex alignment directions into a simplified set of instructions for layman service engineers.

  15. Troponin rise in hospitalized patients with nonacute coronary syndrome: retrospective assessment of outcomes and predictors.

    PubMed

    Dhesi, Sumandeep; Shanks, Miriam; Tymchak, Wayne J

    2015-03-01

    Cardiac troponin is elevated in several clinical settings apart from thrombotic acute coronary syndrome (ACS) and is associated with increased adverse events. It is not clear whether troponin elevation in type II myocardial infarction (MI) is associated with increased cardiovascular events. Our objectives were to identify the cause of mortality in type II MI and to attempt to establish the threshold range of cardiac troponin-I (cTnI) elevation as well as clinical factors associated with adverse outcomes in type II MI. This retrospective cohort study included 245 patients presenting with a noncardiac primary diagnosis associated with cTnI elevation at a single centre from January 2003 to December 2011. Primary outcome was a composite of cardiovascular and noncardiovascular mortality. Secondary outcomes included subsequent stroke, ACS, and heart failure (HF). At 1 year, ACS occurred in 13 patients (5.3%), stroke was seen in 10 (4.1%) patients, and HF occurred in 19 (7.8%) patients. Overall 1-year mortality included 102 events (41.6%), with 10 cardiovascular deaths (9.8%), 65 noncardiovascular deaths (63.7%), and 27 (26.5%) deaths from unknown causes. In multivariable analysis, factors independently associated with increased overall 1-year mortality included cTnI elevation ≥ 4.63 μg/L (odds ratio [OR], 3.37; 95% confidence interval [CI], 1.55-7.34; P = 0.002), age ≥ 70 years (OR, 2.44; 95% CI, 1.40-4.29; P = 0.002), and estimated glomerular filtration rate < 30 mL/min/1.73m(2) (OR, 2.40; 95% CI 1.31-4.40; P = 0.005). Unlike the published literature, our study includes a variety of both operative and nonoperative clinical settings associated with troponin elevation. We illustrate that although overall mortality is high after type II MI, the majority of mortality is caused by noncardiovascular events. Copyright © 2015 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  16. Myocardial protection by glucose-insulin-potassium in acute coronary syndrome patients undergoing urgent multivessel off-pump coronary artery bypass surgery.

    PubMed

    Shim, J-K; Yang, S-Y; Yoo, Y-C; Yoo, K-J; Kwak, Y-L

    2013-01-01

    The aim of this randomized and controlled trial was to investigate the effect of a glucose-insulin-potassium (GIK) solution on myocardial protection in acute coronary syndrome (ACS) patients undergoing urgent multivessel off-pump coronary artery bypass (OPCAB) surgery. Sixty-six patients were randomly allocated either to receive 0.3 ml kg(-1) h(-2) GIK solution (potassium 80 mEq and regular insulin 325 IU in 500 ml of 50% glucose) or equivalent volume of normal saline (control) upon anaesthetic induction until 6 h after reperfusion. The primary endpoints were to compare the concentrations of creatine kinase-MB (CK-MB) and troponin-T between the groups after reperfusion. The secondary endpoints were to compare the incidences of postoperative troponin-T >0.8 ng ml(-1) and myocardial infarction (MI) between the groups. Highest CK-MB [8.7 (4.4) vs 13.1 (7.9) ng ml(-1), P=0.006] and troponin-T [0.20 (0.13-0.49) vs 0.48 (0.18-0.91) ng ml(-1), P<0.0001] values after reperfusion were significantly lower in the GIK group compared with the control group. The area under the curve of serially measured troponin-T was also significantly smaller in the GIK group compared with the control group [0.83 (0.43-1.81) vs 0.46 (0.31-1.00), P=0.036]. Significantly fewer patients in the GIK group showed troponin-T >0.8 ng ml(-1) after reperfusion compared with the control group (3 vs 11, P=0.033). The incidence of postoperative MI was similar between the groups. GIK administration in ACS patients undergoing urgent multivessel OPCAB significantly attenuated the degree of ensuing myocardial injury without complications related to glycaemic control. Clinical Trial Registry. URL: http://clinicaltrials.gov/ct2/show/NCT01384656?term=GIK+AND+OPCAB&rank=1. Unique identification number NCT01384656.

  17. Serial measures of cardiac troponin T levels by a highly sensitive assay and incident atrial fibrillation in a prospective cohort of ambulatory older adults.

    PubMed

    Hussein, Ayman A; Bartz, Traci M; Gottdiener, John S; Sotoodehnia, Nona; Heckbert, Susan R; Lloyd-Jones, Donald; Kizer, Jorge R; Christenson, Robert; Wazni, Oussama; deFilippi, Christopher

    2015-05-01

    Various mechanisms in cardiac remodeling related to atrial fibrillation (AF) lead to elevated circulating cardiac troponin levels, but little is known about such elevations upstream to AF onset. The purpose of this study was to study the association between circulating troponin levels as assessed by a highly sensitive cardiac troponin T (hs-cTnT) assay and incident atrial fibrillation (AF). In a large prospective cohort of ambulatory older adults [the Cardiovascular Health Study (CHS)], hs-cTnT levels were measured in sera that were collected at enrollment from 4262 participants without AF (2871 with follow-up measurements). Incident AF was identified by electrocardiograms during CHS visits, hospital discharge diagnoses, and Medicare files, including outpatient and physician claims diagnoses. Over median follow-up of 11.2 years (interquartile range 6.1-16.5), 1363 participants (32.0%) developed AF. Higher baseline levels of hs-cTnT were associated with incident AF in covariate-adjusted analyses accounting for demographics, traditional risk factors, and incident heart failure in time-dependent analyzes (hazard ratio for 3rd tertile vs undetectable 1.75, 95% confidence interval 1.48-2.08). This association was statistically significant in analyses that additionally adjusted for biomarkers of inflammation and hemodynamic strain (hazard ratio for 3rd tertile vs undetectable 1.38, 95% confidence interval 1.16-1.65). Significant associations were also found when hs-cTnT levels were treated as a continuous variable and when examining change from baseline of hs-cTnT levels and incident AF. The findings show a significant association of circulating troponin levels in ambulatory older adults with incident AF beyond that of traditional risk factors, incident heart failure, and biomarkers of inflammation and hemodynamic strain. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. The structural role of high molecular weight tropomyosins in dipteran indirect flight muscle and the effect of phosphorylation.

    PubMed

    Mateos, Jesús; Herranz, Raúl; Domingo, Alberto; Sparrow, John; Marco, Roberto

    2006-01-01

    In Drosophila melanogaster two high molecular weight tropomyosin isoforms, historically named heavy troponins (TnH-33 and TnH-34), are encoded by the Tm1 tropomyosin gene. They are specifically expressed in the indirect flight muscles (IFM). Their N-termini are conventional and complete tropomyosin sequences, but their C-termini consist of different IFM-specific domains that are rich in proline, alanine, glycine and glutamate. The evidence indicates that in Diptera these IFM-specific isoforms are conserved and are not troponins, but heavy tropomyosins (TmH). We report here that they are post-translationally modified by several phosphorylations in their C-termini in mature flies, but not in recently emerged flies that are incapable of flight. From stoichiometric measurements of thin filament proteins and interactions of the TmH isoforms with the standard Drosophila IFM tropomyosin isoform (protein 129), we propose that the TmH N-termini are integrated into the thin filament structural unit as tropomyosin dimers. The phosphorylated C-termini remain unlocated and may be important in IFM stretch-activation. Comparison of the Tm1 and Tm2 gene sequences shows a complete conservation of gene organisation in other Drosophilidae, such as Drosophila pseudoobscura, while in Anopheles gambiae only one exon encodes a single C-terminal domain, though overall gene organization is maintained. Interestingly, in Apis mellifera (hymenopteran), while most of the Tm1 and Tm2 gene features are conserved, the gene lacks any C-terminal exons. Instead these sequences are found at the 3' end of the troponin I gene. In this insect order, as in Lethocerus (hemipteran), the original designation of troponin H (TnH) should be retained. We discuss whether the insertion of the IFM-specific pro-ala-gly-glu-rich domain into the tropomyosin or troponin I genes in different insect orders may be related to proposals that the IFM stretch activation mechanism has evolved independently several times in higher insects.

  19. Prevalence and outcome of patients referred for chest pain with high sensitivity troponin elevation and no diagnosis at discharge.

    PubMed

    Lordet, Vincent; Lesbordes, Matthieu; Garcia, Rodrigue; Varroud-Vial, Nicolas; Ingrand, Pierre; Christiaens, Luc; Levesque, Sébastien

    2018-05-26

    Specialized chest pain units (CPU) appear to increase the proportion of patients with acute chest pain who are properly evaluated. The aim of this study was to evaluate the survival and occurrence of cardiovascular events in patients without diagnosis at the end of the management of chest pain with high-sensibility troponin elevation. All consecutive patients who came to the cardiac emergency room of Poitiers University Hospital between January 1, 2014 and August 7, 2015 for chest pain and troponin elevation were included. The primary endpoint was the number of undiagnosed patients, and secondary endpoints included survival and major adverse cardiac event (MACE) occurrence in this population. A total of 1001 patients (695 male, mean age 68 ± 16 years) who had chest pain and troponin elevation were included. Median follow-up was 24.5 [14.7; 29.5] months. Forty-seven (4.7%) patients remained without diagnosis. Compared with patients with diagnosis, these patients were younger (53.6 ± 19.7 years, p<0.0001), had less hypertension (29.8%, p<0.0001), less diabetes (4.3%, p=0.0016) and less history of coronary artery disease (CAD) (6.4%, p<0.0001). Their GRACE score was lower (109.3 ± 33.3, p=0.002). None of the followed patients died or had MACE in six months of follow-up. Survival curves showed that the probability of survival was excellent not only at 6 months but also at 36 months (p=0.0025). Fewer than 5% of patients referred for chest pain and with high-sensitivity troponin elevation remained without diagnosis after adapted care in the CPU. Their 6-month prognosis was excellent. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Highly sensitive troponin and coronary computed tomography angiography in the evaluation of suspected acute coronary syndrome in the emergency department.

    PubMed

    Ferencik, Maros; Hoffmann, Udo; Bamberg, Fabian; Januzzi, James L

    2016-08-07

    The evaluation of patients presenting to the emergency department with suspected acute coronary syndrome (ACS) remains a clinical challenge. The traditional assessment includes clinical risk assessment based on cardiovascular risk factors with serial electrocardiograms and cardiac troponin measurements, often followed by advanced cardiac testing as inpatient or outpatient (i.e. stress testing, imaging). Despite this costly and lengthy work-up, there is a non-negligible rate of missed ACS with an increased risk of death. There is a clinical need for diagnostic strategies that will lead to rapid and reliable triage of patients with suspected ACS. We provide an overview of the evidence for the role of highly sensitive troponin (hsTn) in the rapid and efficient evaluation of suspected ACS. Results of recent research studies have led to the introduction of hsTn with rapid rule-in and rule-out protocols into the guidelines. Highly sensitive troponin increases the sensitivity for the detection of myocardial infarction and decreases time to diagnosis; however, it may decrease the specificity, especially when used as a dichotomous variable, rather than continuous variable as recommended by guidelines; this may increase clinician uncertainty. We summarize the evidence for the use of coronary computed tomography angiography (CTA) as the rapid diagnostic tool in this population when used with conventional troponin assays. Coronary CTA significantly decreases time to diagnosis and discharge in patients with suspected ACS, while being safe. However, it may lead to increase in invasive procedures and includes radiation exposure. Finally, we outline the opportunities for the combined use of hsTn and coronary CTA that may result in increased efficiency, decreased need for imaging, lower cost, and decreased radiation dose. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  1. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  2. Determinants and prognostic implications of Cardiac Troponin T measured by a sensitive assay in Type 2 Diabetes Mellitus

    PubMed Central

    2010-01-01

    Background The cardiac troponins are biomarkers used for diagnosis of myocardial injury. They are also powerful prognostic markers in many diseases and settings. Recently introduced high-sensitivity assays indicate that chronic cardiac troponin elevations are common in response to cardiovascular (CV) morbidity. Type 2 diabetes mellitus (T2DM) confers a high risk of CV disease, but little is known about chronic cardiac troponin elevations in diabetic subjects. Accordingly, we aimed to understand the prevalence, determinants, and prognostic implications of cardiac troponin T (cTnT) elevations measured with a high-sensitivity assay in patients with T2DM. Methods cTnT was measured in stored, frozen serum samples from 124 subjects enrolled in the Asker and Bærum Cardiovascular Diabetes trial at baseline and at 2-year follow-up, if availabe (96 samples available). Results were analyzed in relation to baseline variables, hospitalizations, and group assignment (multifactorial intensive versus conventional diabetes care for lowering CV risk). Results One-hundred thirteen (90 %) had detectable cTnT at baseline and of those, 22 (18 % of the total population) subjects had values above the 99th percentile for healthy controls (13.5 ng/L). Levels at baseline were associated with conventional CV risk factors (age, renal function, gender). There was a strong correlation between cTnT levels at the two time-points (r = 0.92, p > 0.001). Risk for hospitalizations during follow-up increased step-wise by quartiles of hscTnT measured at baseline (p = 0.058). Conclusions Elevations of cTnT above the 99th percentile measured by a highly sensitive assay were encountered frequently in a population of T2DM patients. cTnT levels appeared to be stable over time and associated with conventional CV risk factors. Although a clear trend was present, no statistically robust associations with adverse outcomes could be found. PMID:20843304

  3. Determinants and prognostic implications of cardiac troponin T measured by a sensitive assay in type 2 diabetes mellitus.

    PubMed

    Hallén, Jonas; Johansen, Odd Erik; Birkeland, Kåre I; Gullestad, Lars; Aakhus, Svend; Endresen, Knut; Tjora, Solve; Jaffe, Allan S; Atar, Dan

    2010-09-15

    The cardiac troponins are biomarkers used for diagnosis of myocardial injury. They are also powerful prognostic markers in many diseases and settings. Recently introduced high-sensitivity assays indicate that chronic cardiac troponin elevations are common in response to cardiovascular (CV) morbidity. Type 2 diabetes mellitus (T2DM) confers a high risk of CV disease, but little is known about chronic cardiac troponin elevations in diabetic subjects. Accordingly, we aimed to understand the prevalence, determinants, and prognostic implications of cardiac troponin T (cTnT) elevations measured with a high-sensitivity assay in patients with T2DM. cTnT was measured in stored, frozen serum samples from 124 subjects enrolled in the Asker and Bærum Cardiovascular Diabetes trial at baseline and at 2-year follow-up, if available (96 samples available). Results were analyzed in relation to baseline variables, hospitalizations, and group assignment (multifactorial intensive versus conventional diabetes care for lowering CV risk). One-hundred thirteen (90%) had detectable cTnT at baseline and of those, 22 (18% of the total population) subjects had values above the 99th percentile for healthy controls (13.5 ng/L). Levels at baseline were associated with conventional CV risk factors (age, renal function, gender). There was a strong correlation between cTnT levels at the two time-points (r=0.92, p>0.001). Risk for hospitalizations during follow-up increased step-wise by quartiles of hscTnT measured at baseline (p=0.058). Elevations of cTnT above the 99th percentile measured by a highly sensitive assay were encountered frequently in a population of T2DM patients. cTnT levels appeared to be stable over time and associated with conventional CV risk factors. Although a clear trend was present, no statistically robust associations with adverse outcomes could be found.

  4. Isolation, electron microscopic imaging, and 3-D visualization of native cardiac thin myofilaments.

    PubMed

    Spiess, M; Steinmetz, M O; Mandinova, A; Wolpensinger, B; Aebi, U; Atar, D

    1999-06-15

    An increasing number of cardiac diseases are currently pinpointed to reside at the level of the thin myofilaments (e.g., cardiomyopathies, reperfusion injury). Hence the aim of our study was to develop a new method for the isolation of mammalian thin myofilaments suitable for subsequent high-resolution electron microscopic imaging. Native cardiac thin myofilaments were extracted from glycerinated porcine myocardial tissue in the presence of protease inhibitors. Separation of thick and thin myofilaments was achieved by addition of ATP and several centrifugation steps. Negative staining and subsequent conventional and scanning transmission electron microscopy (STEM) of thin myofilaments permitted visualization of molecular details; unlike conventional preparations of thin myofilaments, our method reveals the F-actin moiety and allows direct recognition of thin myofilament-associated porcine cardiac troponin complexes. They appear as "bulges" at regular intervals of approximately 36 nm along the actin filaments. Protein analysis using SDS-polyacrylamide gel electrophoresis revealed that only approximately 20% troponin I was lost during the isolation procedure. In a further step, 3-D helical reconstructions were calculated using STEM dark-field images. These 3-D reconstructions will allow further characterization of molecular details, and they will be useful for directly visualizing molecular alterations related to diseased cardiac thin myofilaments (e.g., reperfusion injury, alterations of Ca2+-mediated tropomyosin switch). Copyright 1999 Academic Press.

  5. Transformation and Alignment in Similarity

    ERIC Educational Resources Information Center

    Hodgetts, Carl J.; Hahn, Ulrike; Chater, Nick

    2009-01-01

    This paper contrasts two structural accounts of psychological similarity: structural alignment (SA) and Representational Distortion (RD). SA proposes that similarity is determined by how readily the structures of two objects can be brought into alignment; RD measures similarity by the complexity of the transformation that "distorts" one…

  6. The Introduction and Clinical Use of Cardiac-Specific Troponin Assays.

    PubMed

    Antman, Elliott M

    2018-01-01

    The earliest biomarkers introduced to diagnose myocardial infarction (MI) such as aspartate aminotransferase (AST) and lactic dehydrogenase (LDH) lacked cardiac specificity and were replaced by creatine kinase (CK), the CK-MB isoenzyme, and ultimately the cardiac-specific troponins (cTnT and cTnI). This has opened up the possibilities of ruling out MI more rapidly and also identifying patients with a chronic elevation of cTn and a poor prognosis in a range of cardiac conditions. © 2017 ASCPT.

  7. Industrial metrology as applied to large physics experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veal, D.

    1993-05-01

    A physics experiment is a large complex 3-D object (typ. 1200 m{sup 3}, 35000 tonnes), with sub-millimetric alignment requirements. Two generic survey alignment tasks can be identified; first, an iterative positioning of the apparatus subsystems in space and, second, a quantification of as-built parameters. The most convenient measurement technique is industrial triangulation but the complexity of the measured object and measurement environment constraints frequently requires a more sophisticated approach. To enlarge the ``survey alignment toolbox`` measurement techniques commonly associated with other disciplines such as geodesy, applied geodesy for accelerator alignment, and mechanical engineering are also used. Disparate observables require amore » heavy reliance on least squares programs for campaign pre-analysis and calculation. This paper will offer an introduction to the alignment of physics experiments and will identify trends for the next generation of SSC experiments.« less

  8. [Differentiation of mesenchymal stem cells into cardiomyocytes induced by cardiomyocytes].

    PubMed

    Wang, Ting-Zhong; Ma, Ai-Qun; Xu, Zheng-Yun; Jiang, Wen-Hui; Du, Yuan

    2005-06-01

    To investigate the role of adult cardiomyocytes in the differentiation of mesenchymal stem cells (MSCs) into cardiomyocytes. Rat MSCs were isolated by a Percoll's gradient solution and cultured in low-glucose Dulbecco' s modified Eagle' s medium (DMEM). After 2 passages, cell-surface antigen CD34, CD71 and CD90 for rat MSCs were determined by flow cytometry, and these MSCs were transfected with pEGFP-N3 by Lipofectamine2000. Then those MSCs labeled with GFP, were cultured in contacted, nocontacted and conditioned with adult rat myocardiocytes. Immunofluorescence staining against alpha-actin, desmin, and troponin-T were performed after 1 week. Immunofluorescence staining was positive against alpha-actin, desmin, and troponin-T on MSCs in contacted culture group. In contrast, no alpha-actin, desmin, and troponin-T expression on MSCs were observed in the noncontacted culture group and the conditioned culture group. Direct cell-to-cell contact between MSCs and adult cardiomyocytes may induce differentiation of MSCs into cardiomyocytes.

  9. Cardiovascular risk in pulmonary alveolar proteinosis.

    PubMed

    Manali, Effrosyni D; Papadaki, Georgia; Konstantonis, Dimitrios; Tsangaris, Iraklis; Papaioannou, Andriana I; Kolilekas, Likurgos; Schams, Andrea; Kagouridis, Konstantinos; Karakatsani, Anna; Orfanos, Stylianos; Griese, Matthias; Papiris, Spyros A

    2016-02-01

    We hypothesized that cardiovascular events and/or indices of cardiac dysfunction may be increased in pulmonary alveolar proteinosis (PAP). Systemic and pulmonary arterial hypertension, arrhythmias, pulmonary embolism, stroke and ischemic heart attack were reported. Patients underwent serum anti-GM-CSF antibodies, disease severity score (DSS), Doppler transthoracic echocardiograph, glucose, thyroid hormones, lipids, troponin and pro-Brain natriuretic peptide (BNP) examination. Thirteen patients (8 female) were studied, median age of 47. Pro-BNP inversely related to DLCO% and TLC%; troponin directly related to DSS, age, P(A-a)O2, left atrium-, left ventricle-end-diastole diameter and BMI. On multiple regression analysis DSS was the only parameter significantly and strongly related with troponin (R(2) = 0.776, p = 0.007). No cardiovascular event was reported during follow-up. In PAP cardiovascular risk indices relate to lung disease severity. Therefore, PAP patients could be at increased risk for cardiovascular events. Quantitation of its magnitude and potential links to lungs' physiologic derangement will be addressed in future studies.

  10. Thematic Roles, Markedness Alignment and Processing Complexity

    ERIC Educational Resources Information Center

    Lee, Yoonhyoung; Kwon, Youan; Gordon, Peter C.

    2015-01-01

    Two experiments used eye-tracking during reading to investigate the role of the consistency of the relative markedness alignment of noun phrases (NPs) in the processing of complex sentences in Korean. To do so, the animacy of the first NP was varied in both experiments to manipulate the relative markedness of NPs. In addition, case markings of the…

  11. Cardiac damage associated with stress hyperglycaemia and acute coronary syndrome changes according to level of presenting blood glucose.

    PubMed

    Al Jumaily, Talib; Rose'Meyer, Roselyn B; Sweeny, Amy; Jayasinghe, Rohan

    2015-10-01

    To determine the prevalence of stress hyperglycaemia in people presenting with acute coronary syndrome (ACS), and the relationships between admission glucose and cardiac damage, cardiovascular mortality and morbidity. In a prospective observational study people presenting with ACS at the Gold Coast Hospital had their admission glucose (AG) level tested to determine stress hyperglycaemia. A range of measurements supplemented this data including troponin levels, category of ACS and major adverse coronary events (MACEs) were obtained through hospital records and patient follow-up post-discharge. One hundred eighty-eight participants were recruited. The prevalence of stress hyperglycaemia in ACS was 44% with 31% having a previous diagnosis of type 2 diabetes and 7.7% had undiagnosed diabetes. The stress hyperglycaemic group had a significantly higher median troponin levels compared to participants with normal blood glucose levels on admission (p<0.05) however the highest presenting glucose group (>15 mmol/L) had troponin levels similar to people presenting with normal blood glucose levels and ACS (p>0.05). Cardiac necrosis as measured by troponin levels is significantly increased in people with ACS and stress hyperglycaemia. This study found that one in four participants presenting with ACS and an admission glucose of >7.0 had no previous diagnosis for diabetes. Consistently ordering HbA1C testing on patients with high AG can enable earlier diagnosis and treatment of diabetes. Copyright © 2015. Published by Elsevier Ireland Ltd.

  12. [The role of biochemical markers with special regard to troponin, CK-MB, NT-proBNP as early biomarkers of cardiotoxicity among women after chemotherapy due to breast cancer].

    PubMed

    Stachowiak, Paweł; Milchert-Leszczyńska, Marta; Falco, Michał; Polakowska, Małgorzata; Wojtarowicz, Andrzej; Kaliszczak, Robert; Safranow, Krzysztof; Kornacewicz-Jach, Zdzisława

    Cardiotoxicity of drugs in oncology is a growing problem which cardiologists and oncologists have to struggle with. So far, researchers have been looking for biochemical markers which could help to extract a group more prone to developing complications after chemotherapy. Authors’ reports are inconsistent in this topic. This study assesses the role of troponin I, CK-MB and NT-proBNP as early predictive markers for later cardiotoxicity among patients with breast cancer treated with chemotherapy. One hundred five patients with breast cancer, without either heart failure or more than moderate severity of valvular heart diseases were qualified to the study. NT-proBNP concentration significantly increased just after the first cycle of chemotherapy, either in a subgroup which developed cardiotoxicity or without this end point (p<0.001, p=0.004). CK-MB did not change significantly during observation. Troponin I did not change in any of the patients. During observation HDL-cholesterol concentration significantly decreased. A transient increase of the concentration of LDL-cholesterol had been noted, but later it decreased below baseline level. Troponin I has too low sensitivity to be used as a prognostic marker for further cardiotoxicity after chemotherapy. No prognostic values have been noted of NT-proBNP and CK-MB due to the lack of differences in both a subgroup with and without cardiotoxicity.

  13. Diagnostic Accuracy of a New High-Sensitivity Troponin I Assay and Five Accelerated Diagnostic Pathways for Ruling Out Acute Myocardial Infarction and Acute Coronary Syndrome.

    PubMed

    Greenslade, Jaimi H; Carlton, Edward W; Van Hise, Christopher; Cho, Elizabeth; Hawkins, Tracey; Parsonage, William A; Tate, Jillian; Ungerer, Jacobus; Cullen, Louise

    2018-04-01

    This diagnostic accuracy study describes the performance of 5 accelerated chest pain pathways, calculated with the new Beckman's Access high-sensitivity troponin I assay. High-sensitivity troponin I was measured with presentation and 2-hour blood samples in 1,811 patients who presented to an emergency department (ED) in Australia. Patients were classified as being at low risk according to 5 rules: modified accelerated diagnostic protocol to assess patients with chest pain symptoms using troponin as the only biomarker (m-ADAPT), the Emergency Department Assessment of Chest Pain Score (EDACS) pathway, the History, ECG, Age, Risk Factors, and Troponin (HEART) pathway, the No Objective Testing Rule, and the new Vancouver Chest Pain Rule. Endpoints were 30-day acute myocardial infarction and acute coronary syndrome. Measures of diagnostic accuracy for each rule were calculated. Data included 96 patients (5.3%) with acute myocardial infarction and 139 (7.7%) with acute coronary syndrome. The new Vancouver Chest Pain Rule and No Objective Testing Rule had high sensitivity for acute myocardial infarction (100%; 95% confidence interval [CI] 96.2% to 100% for both) and acute coronary syndrome (98.6% [95% CI 94.9% to 99.8%] and 99.3% [95% CI 96.1% to 100%]). The m-ADAPT, EDACS, and HEART pathways also yielded high sensitivity for acute myocardial infarction (96.9% [95% CI 91.1% to 99.4%] for m-ADAPT and 97.9% [95% CI 92.7% to 99.7%] for EDACS and HEART), but lower sensitivity for acute coronary syndrome (≤95.0% for all). The m-ADAPT, EDACS, and HEART rules classified more patients as being at low risk (64.3%, 62.5%, and 49.8%, respectively) than the new Vancouver Chest Pain Rule and No Objective Testing Rule (28.2% and 34.5%, respectively). In this cohort with a low prevalence of acute myocardial infarction and acute coronary syndrome, using the Beckman's Access high-sensitivity troponin I assay with the new Vancouver Chest Pain Rule or No Objective Testing Rule enabled approximately one third of patients to be safely discharged after 2-hour risk stratification with no further testing. The EDACS, m-ADAPT, or HEART pathway enabled half of ED patients to be rapidly referred for objective testing. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  14. SPARSE: quadratic time simultaneous alignment and folding of RNAs without sequence-based heuristics

    PubMed Central

    Will, Sebastian; Otto, Christina; Miladi, Milad; Möhl, Mathias; Backofen, Rolf

    2015-01-01

    Motivation: RNA-Seq experiments have revealed a multitude of novel ncRNAs. The gold standard for their analysis based on simultaneous alignment and folding suffers from extreme time complexity of O(n6). Subsequently, numerous faster ‘Sankoff-style’ approaches have been suggested. Commonly, the performance of such methods relies on sequence-based heuristics that restrict the search space to optimal or near-optimal sequence alignments; however, the accuracy of sequence-based methods breaks down for RNAs with sequence identities below 60%. Alignment approaches like LocARNA that do not require sequence-based heuristics, have been limited to high complexity (≥ quartic time). Results: Breaking this barrier, we introduce the novel Sankoff-style algorithm ‘sparsified prediction and alignment of RNAs based on their structure ensembles (SPARSE)’, which runs in quadratic time without sequence-based heuristics. To achieve this low complexity, on par with sequence alignment algorithms, SPARSE features strong sparsification based on structural properties of the RNA ensembles. Following PMcomp, SPARSE gains further speed-up from lightweight energy computation. Although all existing lightweight Sankoff-style methods restrict Sankoff’s original model by disallowing loop deletions and insertions, SPARSE transfers the Sankoff algorithm to the lightweight energy model completely for the first time. Compared with LocARNA, SPARSE achieves similar alignment and better folding quality in significantly less time (speedup: 3.7). At similar run-time, it aligns low sequence identity instances substantially more accurate than RAF, which uses sequence-based heuristics. Availability and implementation: SPARSE is freely available at http://www.bioinf.uni-freiburg.de/Software/SPARSE. Contact: backofen@informatik.uni-freiburg.de Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25838465

  15. A low-complexity add-on score for protein remote homology search with COMER.

    PubMed

    Margelevicius, Mindaugas

    2018-06-15

    Protein sequence alignment forms the basis for comparative modeling, the most reliable approach to protein structure prediction, among many other applications. Alignment between sequence families, or profile-profile alignment, represents one of the most, if not the most, sensitive means for homology detection but still necessitates improvement. We aim at improving the quality of profile-profile alignments and the sensitivity induced by them by refining profile-profile substitution scores. We have developed a new score that represents an additional component of profile-profile substitution scores. A comprehensive evaluation shows that the new add-on score statistically significantly improves both the sensitivity and the alignment quality of the COMER method. We discuss why the score leads to the improvement and its almost optimal computational complexity that makes it easily implementable in any profile-profile alignment method. An implementation of the add-on score in the open-source COMER software and data are available at https://sourceforge.net/projects/comer. The COMER software is also available on Github at https://github.com/minmarg/comer and as a Docker image (minmar/comer). Supplementary data are available at Bioinformatics online.

  16. Regenerating skeletal muscle in the face of aging and disease.

    PubMed

    Jasuja, Ravi; LeBrasseur, Nathan K

    2014-11-01

    Skeletal muscle is a fundamental organ in the generation of force and movement, the regulation of whole-body metabolism, and the provision of resiliency. Indeed, physical medicine and rehabilitation is recognized for optimizing skeletal muscle health in the context of aging (sarcopenia) and disease (cachexia). Exercise is, and will remain, the cornerstone of therapies to improve skeletal muscle health. However, there are now a number of promising biologic and small molecule interventions currently under development to rejuvenate skeletal muscle, including myostatin inhibitors, selective androgen receptor modulators, and an activator of the fast skeletal muscle troponin complex. The opportunities for skeletal muscle-based regenerative therapies and a selection of emerging pharmacologic interventions are discussed in this review.

  17. Parametric and non-parametric masking of randomness in sequence alignments can be improved and leads to better resolved trees.

    PubMed

    Kück, Patrick; Meusemann, Karen; Dambach, Johannes; Thormann, Birthe; von Reumont, Björn M; Wägele, Johann W; Misof, Bernhard

    2010-03-31

    Methods of alignment masking, which refers to the technique of excluding alignment blocks prior to tree reconstructions, have been successful in improving the signal-to-noise ratio in sequence alignments. However, the lack of formally well defined methods to identify randomness in sequence alignments has prevented a routine application of alignment masking. In this study, we compared the effects on tree reconstructions of the most commonly used profiling method (GBLOCKS) which uses a predefined set of rules in combination with alignment masking, with a new profiling approach (ALISCORE) based on Monte Carlo resampling within a sliding window, using different data sets and alignment methods. While the GBLOCKS approach excludes variable sections above a certain threshold which choice is left arbitrary, the ALISCORE algorithm is free of a priori rating of parameter space and therefore more objective. ALISCORE was successfully extended to amino acids using a proportional model and empirical substitution matrices to score randomness in multiple sequence alignments. A complex bootstrap resampling leads to an even distribution of scores of randomly similar sequences to assess randomness of the observed sequence similarity. Testing performance on real data, both masking methods, GBLOCKS and ALISCORE, helped to improve tree resolution. The sliding window approach was less sensitive to different alignments of identical data sets and performed equally well on all data sets. Concurrently, ALISCORE is capable of dealing with different substitution patterns and heterogeneous base composition. ALISCORE and the most relaxed GBLOCKS gap parameter setting performed best on all data sets. Correspondingly, Neighbor-Net analyses showed the most decrease in conflict. Alignment masking improves signal-to-noise ratio in multiple sequence alignments prior to phylogenetic reconstruction. Given the robust performance of alignment profiling, alignment masking should routinely be used to improve tree reconstructions. Parametric methods of alignment profiling can be easily extended to more complex likelihood based models of sequence evolution which opens the possibility of further improvements.

  18. Onorbit IMU alignment error budget

    NASA Technical Reports Server (NTRS)

    Corson, R. W.

    1980-01-01

    The Star Tracker, Crew Optical Alignment Sight (COAS), and Inertial Measurement Unit (IMU) from a complex navigation system with a multitude of error sources were combined. A complete list of the system errors is presented. The errors were combined in a rational way to yield an estimate of the IMU alignment accuracy for STS-1. The expected standard deviation in the IMU alignment error for STS-1 type alignments was determined to be 72 arc seconds per axis for star tracker alignments and 188 arc seconds per axis for COAS alignments. These estimates are based on current knowledge of the star tracker, COAS, IMU, and navigation base error specifications, and were partially verified by preliminary Monte Carlo analysis.

  19. Prognostic implications of high-sensitivity cardiac troponin T assay in a real-world population with non-ST-elevation acute coronary syndrome.

    PubMed

    Magnoni, Marco; Gallone, Guglielmo; Ceriotti, Ferruccio; Vergani, Vittoria; Giorgio, Daniela; Angeloni, Giulia; Maseri, Attilio; Cianflone, Domenico

    2018-09-01

    High-sensitivity cardiac troponin T (hsTnT) was recently approved for clinical use by the Food and Drug Administration. The transition from contemporary to hsTnT assays requires a thorough understanding of the clinical differences between these assays. HsTnT may provide a more accurate prognostic stratification than contemporary cardiac troponin I (cTnI) in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS). HsTnT and cTnI were measured in 644 patients with CK-MB negative NSTE-ACS who were enrolled in the prospective multicenter SPAI (Stratificazione Prognostica dell'Angina Instabile) study. Patients were stratified at the 99th percentile reference limit for each assay. The primary endpoint was cardiovascular death (CVD) or non-fatal myocardial infarction (MI); the secondary endpoint was the occurrence of unstable angina (UA). Follow-up lasted 180 days. Patients with hsTnT ≥99th percentile were at higher risk of CVD/MI (30-day: 5.9% vs 0.8%, p  = 0.001; 180-day: 11.1% vs 4.7%, p  = 0.004), also after adjusting for TIMI Risk Score. No significant difference in CVD/MI at 180-day was found between hsTnT-positive/cTnI-negative and hsTnT-negative/cTnI-negative patients (adjHR 1.61, 95% CI 0.74-3.49, p  = 0.232). Occurrence of UA was not differently distributed between hsTnT groups dichotomized at the 99th percentile (12.4% vs 12.5% p  = 0.54). Our investigation on a real-world NSTE-ACS population showed good prognostic performance of hsTnT in the risk stratification of the hard endpoint, but did not demonstrate the improved prognostic ability of hsTnT over contemporary cTn. Neither troponin assay predicted the recurrence of UA, suggesting the acute rise of cardiac troponin as a marker of severity, but not the occurrence of future coronary instability.

  20. Normal plasma levels of cardiac troponin I measured by the high-sensitivity cardiac troponin I access prototype assay and the impact on the diagnosis of myocardial ischemia.

    PubMed

    Venge, Per; Johnston, Nina; Lindahl, Bertil; James, Stefan

    2009-09-22

    This study sought to evaluate the analytical and clinical performance of the novel hypersensitive cardiac troponin I (cTnI) prototype assay from Beckman Coulter (Fullerton, California). Studies on patients with acute coronary syndromes and on seemingly healthy subjects have shown that even very minor elevations of cardiac troponins are associated with an increased risk of death. However, the normal plasma levels of cardiac troponins are still not known. cTnI plasma levels were measured in 542 healthy subjects, 319 men (age 59.9 +/- 11.8 years) and 213 women (age 59.8 +/- 13.1 years), and in 1,503 randomly selected patients of the GUSTO IV (Global Utilization of Strategies To open Occluded arteries IV) cohort with unstable angina and non-ST-segment elevation myocardial infarctions (MIs). The cTnI levels at 10% coefficient of variation and 20% coefficient of variation imprecision were 0.0033 and 0.0016 microg/l, respectively. The cTnI levels were measurable in >95% of the healthy subjects. The median level of healthy subjects <60 years of age was 0.0032 microg/l (range 0.0011 to 0.0079 microg/l) with the 99th percentile being 0.010 microg/l. No sex differences were observed. A receiver-operator characteristic curve analysis showed an optimal discrimination between healthy subjects and patients at 0.0064 microg/l with a sensitivity of 84.8% (95% confidence interval: 82.8% to 86.6%) and specificity of 89.7% (95% confidence interval: 86.8% to 92.2%). Outcomes as to death and/or MI were significantly different at this level (p < 0.01) in the GUSTO IV cohort. The novel high-sensitivity cTnI prototype assay from Beckman Coulter allows for the first time the measurement of cTnI levels in almost all healthy subjects. Our data indicate that the assay may be a powerful aid in the diagnosis and outcome prediction of patients with suspected myocardial ischemia and question any definition of myocardial infarction.

  1. Troponin elevation in acute ischemic stroke (TRELAS) - protocol of a prospective observational trial

    PubMed Central

    2011-01-01

    Background Levels of the cardiac muscle regulatory protein troponin T (cTnT) are frequently elevated in patients with acute ischemic stroke and elevated cTnT predicts poor outcome and mortality. The pathomechanism of troponin release may relate to co-morbid coronary artery disease and myocardial ischemia or, alternatively, to neurogenic cardiac damage due to autonomic activation after acute ischemic stroke. Therefore, there is uncertainty about how acute ischemic stroke patients with increased cTnT levels should be managed regarding diagnostic and therapeutic workup. Methods/Design The primary objective of the prospective observational trial TRELAS (TRoponin ELevation in Acute ischemic Stroke) is to investigate the frequency and underlying pathomechanism of cTnT elevation in acute ischemic stroke patients in order to give guidance for clinical practice. All consecutive patients with acute ischemic stroke admitted within 72 hours after symptom onset to the Department of Neurology at the Campus Benjamin Franklin of the University Hospital Charité will be screened for cTnT elevations (i.e. >= 0.05 μg/l) on admission and again on the following day. Patients with increased cTnT will undergo coronary angiography within 72 hours. Diagnostic findings of coronary angiograms will be compared with age- and gender-matched patients presenting with Non-ST-Elevation myocardial infarction to the Department of Cardiology. The primary endpoint of the study will be the occurrence of culprit lesions in the coronary angiogram indicating underlying co-morbid obstructive coronary artery disease. Secondary endpoints will be the localization of stroke in the cerebral imaging and left ventriculographic findings of wall motion abnormalities suggestive of stroke-induced global cardiac dysfunction. Discussion TRELAS will prospectively determine the frequency and possible etiology of troponin elevation in a large cohort of ischemic stroke patients. The findings are expected to contribute to clarify pathophysiologic concepts of co-morbid cardiac damage in ischemic stroke patients and also to provide a basis for clinical recommendations for cardiac workup of such patients. Trial registration clinicaltrials.gov NCT01263964 PMID:21824425

  2. Protein Identification Using Top-Down Spectra*

    PubMed Central

    Liu, Xiaowen; Sirotkin, Yakov; Shen, Yufeng; Anderson, Gordon; Tsai, Yihsuan S.; Ting, Ying S.; Goodlett, David R.; Smith, Richard D.; Bafna, Vineet; Pevzner, Pavel A.

    2012-01-01

    In the last two years, because of advances in protein separation and mass spectrometry, top-down mass spectrometry moved from analyzing single proteins to analyzing complex samples and identifying hundreds and even thousands of proteins. However, computational tools for database search of top-down spectra against protein databases are still in their infancy. We describe MS-Align+, a fast algorithm for top-down protein identification based on spectral alignment that enables searches for unexpected post-translational modifications. We also propose a method for evaluating statistical significance of top-down protein identifications and further benchmark various software tools on two top-down data sets from Saccharomyces cerevisiae and Salmonella typhimurium. We demonstrate that MS-Align+ significantly increases the number of identified spectra as compared with MASCOT and OMSSA on both data sets. Although MS-Align+ and ProSightPC have similar performance on the Salmonella typhimurium data set, MS-Align+ outperforms ProSightPC on the (more complex) Saccharomyces cerevisiae data set. PMID:22027200

  3. Cardiac injury biomarkers in paediatric age: Are we there yet?

    PubMed

    Neves, Ana L; Henriques-Coelho, Tiago; Leite-Moreira, Adelino; Areias, José C

    2016-11-01

    The aim of this article is to evaluate the clinical utility of cardiac injury biomarkers in paediatric age. In December 2015, a literature search was performed (PubMed access to MEDLINE citations; http://www.ncbi.nlm.nih.gov/PubMed/ ). The search strategy included the following medical subject headings and text terms for the key words: "cardiac injury biomarkers", "creatine kinase-MB", "myoglobin", "troponin", "children", "neonate/s", "newborn/s", "infant/s" and echocardiography. In the paediatric population, troponins show a good correlation with the extent of myocardial damage following cardiac surgery and cardiotoxic medication and can be used as predictors of subsequent cardiac recovery and mortality. Elevation of cardiac injury biomarkers may also have diagnostic value in cases when cardiac contusion or pericarditis is suspected. Cardiac injury biomarkers are very sensitive markers for the detection of myocardial injury and have been studied in healthy newborns, after tocolysis, intrauterine growth restriction, respiratory distress and asphyxia. The proportion of newborns with elevated troponin was higher than that in ill infants, children, and adolescents and in healthy adults, suggesting that myocardial injury, although clinically occult, is common in this young age group. Results suggest that significant elevation of cord troponin is an excellent early predictor of severity of hypoxic-ischaemic encephalopathy and mortality in term infants. Cardiac biomarkers may also benefit centres without on-site echocardiography with evidence showing good correlation with echo-derived markers of myocardial function. Further studies are needed to better clarify the role of cardiac biomarkers in paediatric age and their correlation with echocardiographic parameters.

  4. [A case of an allergic reaction due to Anisakis simplex possibly after the ingestion of squid--successful detection of four A. simplex allergens, Ani s 1, Ani s 2, Ani s 12 and troponin C-like protein].

    PubMed

    Iijima, Shigeruko; Moriyama, Tatsuya; Ichikawa, Hidetaka; Kobayashi, Yukihiro; Shiomi, Kazuo

    2012-08-01

    A 62-year-old man ingested dressed salmon and its roe (ikura) and grilled mackerel and one hour later further ingested raw tuna and squid as an evening meal at a bar. Soon after the ingestion of raw seafood, he showed wheals, loss of consciousness and low blood pressure. Specific serum IgE to the nematode Anisakis simplex was positive but those to some seafoods were negative. Moreover, a skin prick test using the crude extract was positive for A. simplex but negative for the seafoods, which he ingested on the day of the above episode. When the A. simplex extract was analyzed by IgE-binding immunoblot analysis using the patient serum, two highly intense protein bands were recognized at 18 and 17 kDa, one intense band at 35 kDa and two weak bands at 28 and 26 kDa. ELISA with 11 natural or recombinant A. simplex allergens (Ani s 1-6, 8, 9, 11 and 12 and troponin C-like protein) showed that the patient serum strongly reacted to Ani s 1 and Ani s 12 and weakly to Ani s 2 and troponin C-like protein. Based on these results, he was diagnosed as IgE-mediated A. simplex allergy due to four allergens (Ani s 1, Ani s 2, Ani s 12 and troponin C-like protein), possibly infested in the raw squid which he had ingested just before manifestation of allergic reactions.

  5. Acute effects of implantable cardioverter-defibrillator shocks on biomarkers of myocardial injury, apoptosis, heart failure, and systemic inflammation

    PubMed Central

    Brewster, Jordan; Sexton, Travis; Dhaliwal, Gary; Charnigo, Richard; Morales, Gustavo; Parrott, Kevin; Darrat, Yousef; Gurley, John; Smyth, Susan; Elayi, Claude S.

    2017-01-01

    Background ICD shocks are potentially associated with myocardial injury, altered hemodynamics, apoptosis and inflammatory signaling. Their precise cellular impact can be explored after defibrillation testing (DFT) via biomarkers. We evaluated changes in biomarkers after ICD shocks during DFT. Methods We prospectively enrolled outpatients presenting for first implantation of a cardiac device. Biomarkers indicative of myocardial injury, inflammation and apoptosis were measured before and after implantation, and compared between patients receiving DFT (DFT+) to those not (DFT−). Results Sixty-three patients were enrolled, 40 in the DFT+ group and 23 in the DFT− group. Average levels of troponin I, hsCRP, Calprotectin, NTproBNP, and sFas increased by >50% after cardiac device implantation compared to baseline. Increase in troponin never exceeded 50 fold upper limit of normal (2ng/mL). Troponin trended higher in the DFT+ group at 8 hours (median 0.18 ng/mL, IQR 0.11–0.48) versus the DFT− group (0.10 ng/mL, IQR 0.06–0.28, P=0.0501); NTproBNP had a similar trend (p=0.0581). sFas significantly increased in the DFT+ group from baseline (median 4663 pg/mL, IQR 2908–5679) to 24 hours (5039 pg/mL, IQR 3274–6261; p=0.0338) but not in the DFT− group (p=0.4705). Conclusion DFT testing is associated with acutely increased plasma levels of troponin and sFas, a biomarker of apoptosis, along with a trend towards higher NTproBNP. PMID:28156007

  6. Role of troponin I proteolysis in the pathogenesis of stunned myocardium.

    PubMed

    Gao, W D; Atar, D; Liu, Y; Perez, N G; Murphy, A M; Marban, E

    1997-03-01

    Myocardial stunning is characterized by decreased myofilament Ca2+ responsiveness. To investigate the molecular basis of stunned myocardium, we performed PAGE and Western immunoblot analysis of the contractile proteins. Isolated rat hearts were retrogradely perfused at 37 degrees C for either 50 minutes (control group) or for 10 minutes, followed by 20-minute global ischemia and 20-minute reperfusion (stunned group), or for 20-minute ischemia without reflow. Another group consisted of hearts subjected to 20-minute ischemia in which stunning was mitigated by 10-minute reperfusion with low Ca2+/low pH solution. Myocardial tissue samples subjected to PAGE revealed no obvious differences among groups. Western immunoblots for actin, tropomyosin, troponin C, troponin T, myosin light chain-1, and myosin light chain-2 showed highly selective recognition of the appropriate full-length molecular weight bands in all groups. Troponin I (TnI) Western blots revealed an additional band (approximately 26 kD, compared with 32 kD for the full-length protein) in stunned myocardial samples only. In parallel experiments, skinned trabeculae were treated with calpain I for 20 minutes; Western blots showed a TnI degradation pattern similar to that observed in stunned myocardium. Such TnI degradation was prevented by calpastatin, a naturally occurring calpain inhibitor. The results show that (1) TnI is partially and selectively degraded in stunned myocardium; (2) this degradation could be prevented by low Ca2+/low pH reperfusion, which also prevented the contractile dysfunction of stunning; and (3) calpain I could similarly degrade TnI, supporting the idea that Ca(2+)-dependent myofilament proteolysis underlies myocardial stunning.

  7. Mutual Alignment Comparison Facilitates Abstraction and Transfer of a Complex Scientific Concept

    ERIC Educational Resources Information Center

    Orton, Judy M.; Anggoro, Florencia K.; Jee, Benjamin D.

    2012-01-01

    Learning about a scientific concept often occurs in the context of unfamiliar examples. Mutual alignment analogy--a type of analogical comparison in which the analogues are only partially understood--has been shown to facilitate learning from unfamiliar examples . In the present study, we examined the role of mutual alignment analogy in the…

  8. Molecular and immunohistochemical analyses of cardiac troponin T during cardiac development in the Mexican axolotl, Ambystoma mexicanum.

    PubMed

    Zhang, C; Pietras, K M; Sferrazza, G F; Jia, P; Athauda, G; Rueda-de-Leon, E; Rveda-de-Leon, E; Maier, J A; Dube, D K; Lemanski, S L; Lemanski, L F

    2007-01-01

    The Mexican axolotl, Ambystoma mexicanum, is an excellent animal model for studying heart development because it carries a naturally occurring recessive genetic mutation, designated gene c, for cardiac nonfunction. The double recessive mutants (c/c) fail to form organized myofibrils in the cardiac myoblasts resulting in hearts that fail to beat. Tropomyosin expression patterns have been studied in detail and show dramatically decreased expression in the hearts of homozygous mutant embryos. Because of the direct interaction between tropomyosin and troponin T (TnT), and the crucial functions of TnT in the regulation of striated muscle contraction, we have expanded our studies on this animal model to characterize the expression of the TnT gene in cardiac muscle throughout normal axolotl development as well as in mutant axolotls. In addition, we have succeeded in cloning the full-length cardiac troponin T (cTnT) cDNA from axolotl hearts. Confocal microscopy has shown a substantial, but reduced, expression of TnT protein in the mutant hearts when compared to normal during embryonic development. 2006 Wiley-Liss, Inc.

  9. A fit-for-purpose approach to analytical sensitivity applied to a cardiac troponin assay: time to escape the 'highly-sensitive' trap.

    PubMed

    Ungerer, Jacobus P J; Pretorius, Carel J

    2014-04-01

    Highly-sensitive cardiac troponin (cTn) assays are being introduced into the market. In this study we argue that the classification of cTn assays into sensitive and highly-sensitive is flawed and recommend a more appropriate way to characterize analytical sensitivity of cTn assays. The raw data of 2252 cardiac troponin I (cTnI) tests done in duplicate with a 'sensitive' assay was extracted and used to calculate the cTnI levels in all, including those below the 'limit of detection' (LoD) that were censored. Duplicate results were used to determine analytical imprecision. We show that cTnI can be quantified in all samples including those with levels below the LoD and that the actual margins of error decrease as concentrations approach zero. The dichotomous classification of cTn assays into sensitive and highly-sensitive is theoretically flawed and characterizing analytical sensitivity as a continuous variable based on imprecision at 0 and the 99th percentile cut-off would be more appropriate.

  10. Endogenous Cardiac Troponin T Modulates Ca2+-Mediated Smooth Muscle Contraction

    PubMed Central

    Kajioka, Shunichi; Takahashi-Yanaga, Fumi; Shahab, Nouval; Onimaru, Mitsuho; Matsuda, Miho; Takahashi, Ryosuke; Asano, Haruhiko; Morita, Hiromitsu; Morimoto, Sachio; Yonemitsu, Yoshikazu; Hayashi, Maya; Seki, Narihito; Sasaguri, Toshiuyki; Hirata, Masato; Nakayama, Shinsuke; Naito, Seiji

    2012-01-01

    Mechanisms linked to actin filaments have long been thought to cooperate in smooth muscle contraction, although key molecules were unclear. We show evidence that cardiac troponin T (cTnT) substantially contributes to Ca2+-mediated contraction in a physiological range of cytosolic Ca2+ concentration ([Ca2+]i). cTnT was detected in various smooth muscles of the aorta, trachea, gut and urinary bladder, including in humans. Also, cTnT was distributed along with tropomyosin in smooth muscle cells, suggesting that these proteins are ready to cause smooth muscle contraction. In chemically permeabilised smooth muscle of cTnT+/− mice in which cTnT reduced to ~50%, the Ca2+-force relationship was shifted toward greater [Ca2+]i, indicating a sizeable contribution of cTnT to smooth muscle contraction at [Ca2+]i < 1 μM. Furthermore, addition of supplemental TnI and TnC reconstructed a troponin system to enhance contraction. The results indicated that a Tn/Tn-like system on actin-filaments cooperates together with the thick-filament pathway. PMID:23248744

  11. Altered Tnnt3 characterizes selective weakness of fast fibers in mice overexpressing FSHD region gene 1 (FRG1)

    PubMed Central

    Sancisi, Valentina; Germinario, Elena; Esposito, Alessandra; Morini, Elisabetta; Peron, Samantha; Moggio, Maurizio; Tomelleri, Giuliano; Danieli-Betto, Daniela

    2013-01-01

    Facioscapulohumeral muscular dystrophy (FSHD), a common hereditary myopathy, is characterized by atrophy and weakness of selective muscle groups. FSHD is considered an autosomal dominant disease with incomplete penetrance and unpredictable variability of clinical expression within families. Mice overexpressing FRG1 (FSHD region gene 1), a candidate gene for this disease, develop a progressive myopathy with features of the human disorder. Here, we show that in FRG1-overexpressing mice, fast muscles, which are the most affected by the dystrophic process, display anomalous fast skeletal troponin T (fTnT) isoform, resulting from the aberrant splicing of the Tnnt3 mRNA that precedes the appearance of dystrophic signs. We determine that muscles of FRG1 mice develop less strength due to impaired contractile properties of fast-twitch fibers associated with an anomalous MyHC-actin ratio and a reduced sensitivity to Ca2+. We demonstrate that the decrease of Ca2+ sensitivity of fast-twitch fibers depends on the anomalous troponin complex and can be rescued by the substitution with the wild-type proteins. Finally, we find that the presence of aberrant splicing isoforms of TNNT3 characterizes dystrophic muscles in FSHD patients. Collectively, our results suggest that anomalous TNNT3 profile correlates with the muscle impairment in both humans and mice. On the basis of these results, we propose that aberrant fTnT represents a biological marker of muscle phenotype severity and disease progression. PMID:24305066

  12. An electrochemical immunosensor for cardiac Troponin I using electrospun carboxylated multi-walled carbon nanotube-whiskered nanofibres.

    PubMed

    Rezaei, Babak; Shoushtari, Ahmad Mousavi; Rabiee, Mohammad; Uzun, Lokman; Mak, Wing Cheung; Turner, Anthony P F

    2018-05-15

    A sandwich-type nanostructured immunosensor based on carboxylated multi-walled carbon nanotube (CMWCNT)-embedded whiskered nanofibres (WNFs) was developed for detection of cardiac Troponin I (cTnI). WNFs were directly fabricated on glassy carbon electrodes (GCE) by removing the sacrificial component (polyethylene glycol, PEG) after electrospinning of polystyrene/CMWCNT/PEG nanocomposite nanofibres, and utilised as a transducer layer for enzyme-labeled amperometric immunoassay of cTnI. The whiskered segments of CMWCNTs were activated and utilised to immobilise anti-cTnT antibodies. It was observed that the anchored CMWCNTs within the nanofibres were suitably stabilised with excellent electrochemical repeatability. A sandwich-type immuno-complex was formed between cTnI and horseradish peroxidase-conjugated anti-cTnI (HRP-anti-cTnI). The amperometric responses of the immunosensor were studied using cyclic voltammetry (CV) through an enzymatic reaction between hydrogen peroxide and HRP conjugated to the secondary antibody. The nanostructured immunosensor delivered a wide detection range for cTnI from the clinical borderline for a normal person (0.5-2ngmL -1 ) to the concentration present in myocardial infarction patients (> 20ngmL -1 ), with a detection limit of ~ 0.04ngmL -1 . It also showed good reproducibility and repeatability for three different cTnI concentration (1, 10 and 25ngmL -1 ) with satisfactory relative standard deviations (RSD). Hence, the proposed nanostructured immunosensor shows potential for point-of-care testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Structure of the F–actin–tropomyosin complex

    PubMed Central

    von der Ecken, Julian; Müller, Mirco; Lehman, William; Manstein, Dietmar J.; Penczek, Pawel A.; Raunser, Stefan

    2015-01-01

    Filamentous actin (F-actin) is the major protein of muscle thin filaments, and actin microfilaments are the main component of the eukaryotic cytoskeleton. Mutations in different actin isoforms lead to early-onset autosomal dominant non-syndromic hearing loss1, familial thoracic aortic aneurysms and dissections2, and multiple variations of myopathies3. In striated muscle fibres, the binding of myosin motors to actin filaments is mainly regulated by tropomyosin and troponin4,5. Tropomyosin also binds to F-actin in smooth muscle and in non-muscle cells and stabilizes and regulates the filaments there in the absence of troponin6. Although crystal structures for monomeric actin (G-actin) are available7, a high-resolution structure of F-actin is still missing, hampering our understanding of how disease-causing mutations affect the function of thin muscle filaments and microfilaments. Here we report the three-dimensional structure of F-actin at a resolution of 3.7 ångstroms in complex with tropomyosin at a resolution of 6.5ångstroms, determined by electron cryomicroscopy. The structure reveals that the D-loop is ordered and acts as a central region for hydrophobic and electrostatic interactions that stabilize the F-actin filament. We clearly identify the density corresponding to ADP and Mg2+ and explain the possible effect of prominent disease-causing mutants. A comparison of F-actin with G-actin reveals the conformational changes during filament formation and identifies the D-loop as their key mediator. We also confirm that negatively charged tropomyosin interacts with a positively charged groove on F-actin. Comparison of the position of tropomyosin in F-actin–tropomyosin with its position in our previously determined actin–tropomyosin–myosin structure8 reveals a myosin-induced transition of tropomyosin. Our results allow us to understand the role of individual mutations in the genesis of actin- and tropomyosin-related diseases and will serve as a strong foundation for the targeted development of drugs. PMID:25470062

  14. Reversed-polarity regions

    NASA Technical Reports Server (NTRS)

    Tang, F.

    1980-01-01

    The 58 RPRS studied have a lifespan comparable to normal active regions and have no tendency to rotate toward a more normal alignment. They seem to have stable configurations with no apparent evidence suggesting stress due to their anomalous magnetic alignment. Magnetic complexity in RPRs is the key to flare productivity just as it is in normal regions - weak field RPRs produced no flares and regions with complex spots produced more flares than regions with noncomplex spots by a factor of 5. The RPRs however, differ from normal regions in the frequency of having complex spots, particularly the long lived complex spots, in them. Less than 17 percent of normal ARs have complex spots; less than 1.8 percent have long lived complex spots. In contrast, 41 percent of RPRs have complex spots and 24 percent have long lived complex spots.

  15. Impact of elevated cardiac biomarkers on mortality after vascular surgery procedures.

    PubMed

    Buckley, Ryan; Stevens, Scott L

    2014-12-01

    Concurrent cardiac disease is an important cause of morbidity and mortality in vascular surgical patients. Increasingly, cardiac biomarkers are used to identify cardiac injury in these high-risk patients. This review provides data demonstrating that perioperative troponin elevation correlates with poor short- and long-term outcomes for vascular surgical patients. In addition, the data demonstrate that patients with high circulating troponin levels fair worse than those with lower levels. Early identification of patients with cardiac injury using biomarkers allows timely diagnosis, risk stratification, and aggressive medical therapy for vascular surgical patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Mesalamine hypersensitivity and Kounis syndrome in a pediatric ulcerative colitis patient

    PubMed Central

    Kounis, George N; Kouni, Sophia A; Hahalis, George; Kounis, Nicholas G

    2008-01-01

    5-aminosalicylic acid (mesalamine) rarely induces hypersensitivity reactions. If chest pain associated with atypical electrocardiographic changes are seen during its administration, one should always bear in mind typeIvariant of Kounis syndrome. This variant includes patients, of any age, with normal coronary arteries, without predisposing factors for coronary artery disease, in whom the acute release of inflammatory mediators from mast cells can induce either sudden coronary artery narrowing, without increase of cardiac enzymes and troponins, or coronary artery spasm that progresses to acute myocardial infarction, with elevated cardiac enzymes and troponins. PMID:19084925

  17. L’investigation de la contusion myocardique pour la fracture sternale à l’urgence

    PubMed Central

    Audette, Jean-Sébastien; Émond, Marcel; Scott, Hugh; Lortie, Gilles

    2014-01-01

    Résumé Objectif Décrire la pratique d’acquisition d’un électrocardiogramme (ECG) initial, d’ECG de contrôle ou d’un monitoring équivalent et du dosage des troponines chez les patients avec une fracture sternale évalués au département d’urgence ou par un médecin de première ligne. Type d’étude Étude rétrospective descriptive multicentrique. Contexte Deux centres académiques de traumatologie de la région de Québec au Canada. Participants 54 patients ayant subi une fracture sternale traumatique. Interventions Évaluation de l’acquisition d’ECG initial et à 6 heures post-traumatisme ou un monitoring équivalent ainsi que le dosage des troponines sanguines. Principaux paramètres à l’étude En ce qui concerne l’ECG, les critères de comparaison de qualité furent sélectionnés à partir d’opinions d’experts rapportées dans quatre études. L’utilisation d’un ECG initial et de contrôle 6 heures post-traumatisme ou d’un monitoring cardiaque de 6 heures représente la pratique recommandée par la plupart de ceux-ci pour le diagnostic de la contusion myocardique dans la fracture sternale. L’utilisation des troponines I sanguines, 4 à 8 heures suivant un traumatisme thoracique, a également été proposée par certains auteurs comme méthode de détection efficace des arythmies significatives secondaires à la contusion myocardique. Des analyses descriptives univariées et des tests de chi-carré furent effectués. Une valeur P < ,05 fut considérée significative. Résultats Trente-neuf (72 %) patients ont été évalués initialement avec un ECG, tandis que 18 (33 %) de ces patients ont eu une évaluation par ECG ou monitoring cardiaque après 6 heures à l’urgence. Seize patients (30 %) ont été évalués à l’aide du dosage des troponines I. Deux patients (4 %) ont présenté des anomalies électrocardiographiques et un seul patient (2 %) a présenté des troponines I élevées. Conclusion Les urgentologues doivent augmenter leur utilisation de l’ECG comme outil diagnostic initial et de contrôle pour les patients ayant subi une fracture sternale traumatique afin de détecter la contusion myocardique et l’arythmie. L’utilisation de la troponinémie, de concert avec l’ECG, est également suggérée dans cette population pour l’identification des patients à risque de complications secondaires à leur contusion myocardique.

  18. ChromAlign: A two-step algorithmic procedure for time alignment of three-dimensional LC-MS chromatographic surfaces.

    PubMed

    Sadygov, Rovshan G; Maroto, Fernando Martin; Hühmer, Andreas F R

    2006-12-15

    We present an algorithmic approach to align three-dimensional chromatographic surfaces of LC-MS data of complex mixture samples. The approach consists of two steps. In the first step, we prealign chromatographic profiles: two-dimensional projections of chromatographic surfaces. This is accomplished by correlation analysis using fast Fourier transforms. In this step, a temporal offset that maximizes the overlap and dot product between two chromatographic profiles is determined. In the second step, the algorithm generates correlation matrix elements between full mass scans of the reference and sample chromatographic surfaces. The temporal offset from the first step indicates a range of the mass scans that are possibly correlated, then the correlation matrix is calculated only for these mass scans. The correlation matrix carries information on highly correlated scans, but it does not itself determine the scan or time alignment. Alignment is determined as a path in the correlation matrix that maximizes the sum of the correlation matrix elements. The computational complexity of the optimal path generation problem is reduced by the use of dynamic programming. The program produces time-aligned surfaces. The use of the temporal offset from the first step in the second step reduces the computation time for generating the correlation matrix and speeds up the process. The algorithm has been implemented in a program, ChromAlign, developed in C++ language for the .NET2 environment in WINDOWS XP. In this work, we demonstrate the applications of ChromAlign to alignment of LC-MS surfaces of several datasets: a mixture of known proteins, samples from digests of surface proteins of T-cells, and samples prepared from digests of cerebrospinal fluid. ChromAlign accurately aligns the LC-MS surfaces we studied. In these examples, we discuss various aspects of the alignment by ChromAlign, such as constant time axis shifts and warping of chromatographic surfaces.

  19. Enabling complex nanoscale pattern customization using directed self-assembly.

    PubMed

    Doerk, Gregory S; Cheng, Joy Y; Singh, Gurpreet; Rettner, Charles T; Pitera, Jed W; Balakrishnan, Srinivasan; Arellano, Noel; Sanders, Daniel P

    2014-12-16

    Block copolymer directed self-assembly is an attractive method to fabricate highly uniform nanoscale features for various technological applications, but the dense periodicity of block copolymer features limits the complexity of the resulting patterns and their potential utility. Therefore, customizability of nanoscale patterns has been a long-standing goal for using directed self-assembly in device fabrication. Here we show that a hybrid organic/inorganic chemical pattern serves as a guiding pattern for self-assembly as well as a self-aligned mask for pattern customization through cotransfer of aligned block copolymer features and an inorganic prepattern. As informed by a phenomenological model, deliberate process engineering is implemented to maintain global alignment of block copolymer features over arbitrarily shaped, 'masking' features incorporated into the chemical patterns. These hybrid chemical patterns with embedded customization information enable deterministic, complex two-dimensional nanoscale pattern customization through directed self-assembly.

  20. Myocardial Injury in Patients With Sepsis and Its Association With Long-Term Outcome.

    PubMed

    Frencken, Jos F; Donker, Dirk W; Spitoni, Cristian; Koster-Brouwer, Marlies E; Soliman, Ivo W; Ong, David S Y; Horn, Janneke; van der Poll, Tom; van Klei, Wilton A; Bonten, Marc J M; Cremer, Olaf L

    2018-02-01

    Sepsis is frequently complicated by the release of cardiac troponin, but the clinical significance of this myocardial injury remains unclear. We studied the associations between troponin release during sepsis and 1-year outcomes. We enrolled consecutive patients with sepsis in 2 Dutch intensive care units between 2011 and 2013. Subjects with a clinically apparent cause of troponin release were excluded. High-sensitivity cardiac troponin I (hs-cTnI) concentration in plasma was measured daily during the first 4 intensive care unit days, and multivariable Cox regression analysis was used to model its association with 1-year mortality while adjusting for confounding. In addition, we studied cardiovascular morbidity occurring during the first year after hospital discharge. Among 1258 patients presenting with sepsis, 1124 (89%) were eligible for study inclusion. Hs-cTnI concentrations were elevated in 673 (60%) subjects on day 1, and 755 (67%) ever had elevated levels in the first 4 days. Cox regression analysis revealed that high hs-cTnI concentrations were associated with increased death rates during the first 14 days (adjusted hazard ratio, 1.72; 95% confidence interval, 1.14-2.59 and hazard ratio, 1.70; 95% confidence interval, 1.10-2.62 for hs-cTnI concentrations of 100-500 and >500 ng/L, respectively) but not thereafter. Furthermore, elevated hs-cTnI levels were associated with the development of cardiovascular disease among 200 hospital survivors who were analyzed for this end point (adjusted subdistribution hazard ratio, 1.25; 95% confidence interval, 1.04-1.50). Myocardial injury occurs in the majority of patients with sepsis and is independently associated with early-but not late-mortality, as well as postdischarge cardiovascular morbidity. © 2018 American Heart Association, Inc.

  1. Combining presentation high-sensitivity cardiac troponin I and glucose measurements to rule-out an acute myocardial infarction in patients presenting to emergency department with chest pain.

    PubMed

    Greenslade, J H; Kavsak, P; Parsonage, W; Shortt, C; Than, M; Pickering, J W; Aldous, S; Cullen, L

    2015-03-01

    The use of high sensitivity troponin (hs-Tn) may enable early rule out of acute myocardial infarction (AMI) for patients presenting to the emergency department (ED) with chest pain. This study evaluated two approaches to the early rule out of AMI; a combination of a presentation hs-Tn <4ng/L and normal glucose at presentation (dual testing) and a presentation hs-Tn troponin below the limit of detection (LoD). We utilised prospectively collected data on adult patients presenting with suspected ACS in two EDs in Australia and New Zealand. Blood samples were taken on presentation and tested for glucose and high sensitivity troponin I. The primary endpoint was index AMI and the secondary endpoint was 30-day acute coronary syndrome (ACS). Sensitivity, specificity, positive and negative predictive values were used to assess the diagnostic accuracy of the dual testing and LoD approaches. Of the 1412 participants, 182 (12.9%) had index AMI. The LoD and the dual testing approach were 100% sensitive for index AMI. The specificity of the dual testing approach (25.2%) was slightly higher than that of the LoD (20.4%). Sensitivity for ACS was similar for the two approaches (96.5% for dual testing and 98.1% for the LoD). The dual testing and LoD approach identified all patients with index AMI and could be used to reduce the proportion of patients requiring lengthy assessment and inpatient admission. Further investigation is still required to rule out unstable angina pectoris in patients identified as low risk. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

    PubMed

    Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna

    2014-11-01

    International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.

  3. Asia-Pacific consensus statement on the optimal use of high-sensitivity troponin assays in acute coronary syndromes diagnosis: focus on hs-TnI

    PubMed Central

    Tan, Jack Wei Chieh; Lam, Carolyn S P; Kasim, Sazzli Shahlan; Aw, Tar Choon; Abanilla, Joel M; Chang, Wei-Ting; Dang, Van Phuoc; Iboleon-Dy, Maria; Mumpuni, Sari Sri; Phommintikul, Arintaya; Ta, Manh Cuong; Topipat, Punkiat; Yiu, Kai Hang; Cullen, Louise

    2017-01-01

    Objective High-sensitivity troponin (hs-Tn) assays need to be applied appropriately to improve diagnosis and patient outcomes in acute coronary syndromes (ACS). Methods Experts from Asia Pacific convened in 2015 to provide data-driven consensus-based, region-specific recommendations and develop an algorithm for the appropriate incorporation of this assay into the ACS assessment and treatment pathway. Results Nine recommendations were developed by the expert panel: (1) troponin is the preferred cardiac biomarker for diagnostic assessment of ACS and is indicated for patients with symptoms of possible ACS; (2) hs-Tn assays are recommended; (3) serial testing is required for all patients; (4) testing should be performed at presentation and 3 hours later; (5) gender-specific cut-off values should be used for hs-Tn I assays; (6) hs-Tn I level >10 times the upper limit of normal should be considered to ‘rule in’ a diagnosis of ACS; (7) dynamic change >50% in hs-Tn I level from presentation to 3-hour retest identifies patients at high risk for ACS; (8) where only point-of-care testing is available, patients with elevated readings should be considered at high risk, while patients with low/undetectable readings should be retested after 6 hours or sent for laboratory testing and (9) regular education on the appropriate use of troponin tests is essential. Conclusions We propose an algorithm that will potentially reduce delays in discharge by the accurate ‘rule out’ of non-ACS patients within 3 hours. Appropriate research should be undertaken to ensure the efficacy and safety of the algorithm in clinical practice, with the long-term goal of improvement of care of patients with ACS in Asia Pacific. PMID:28466882

  4. The Cardiomyopathy Mutation, R146G Troponin I, Stabilizes the Intermediate "C" State of Regulated Actin under High- and Low-Free Ca(2+) Conditions.

    PubMed

    Johnson, Dylan; Mathur, Mohit C; Kobayashi, Tomoyoshi; Chalovich, Joseph M

    2016-08-16

    The R146G mutation of troponin I (TnI) is associated with hypertrophic cardiomyopathy in humans. Earlier data pointed to stabilization of the intermediate, C state, of actin-tropomyosin-troponin by this mutant. Because cardiac disorders appear to be linked to changes in regulated actin distributions, we determined the extent to which the R146G TnI mutant alters the distribution of states at low and high Ca(2+) concentrations. We show, from measurements of the kcat for actin-activated ATPase activity at saturating Ca(2+) concentrations, that R146G TnI reduced the population of the active, M, state to 25% of the wild-type level. Together with acrylodan-tropomyosin fluorescence measurements of the B state, it appeared that the C state was populated at ∼91% of the total for the R146G TnI-containing actin filaments. The C state was also more heavily populated at low Ca(2+) concentrations. Acrylodan-tropomyosin fluorescence changes showed a large diminution in the inactive state value relative to the wild-type value without a comparable increase in the active state. Furthermore, the rate of binding of rigor S1 to pyrene-labeled actin filaments containing R146G TnI was faster than the rate of binding to wild-type filaments at low free Ca(2+) concentrations. These results indicate that the inhibitory region of TnI affects the B-C and M-C equilibria of actin-tropomyosin-troponin. The observation that a mutation in the inhibitory region affects the M-C equilibrium may point to a novel regulatory interaction.

  5. Subclinical Atherosclerosis, Cardiac and Kidney Function, Heart Failure, and Dementia in the Very Elderly.

    PubMed

    Kuller, Lewis H; Lopez, Oscar L; Gottdiener, John S; Kitzman, Dalane W; Becker, James T; Chang, Yuefang; Newman, Anne B

    2017-07-22

    Heart failure (HF) and dementia are major causes of disability and death among older individuals. Risk factors and biomarkers of HF may be determinants of dementia in the elderly. We evaluated the relationship between biomarkers of cardiovascular disease and HF and risk of dementia and death. Three hypotheses were tested: (1) higher levels of high-sensitivity cardiac troponin T, N-terminal of prohormone brain natriuretic peptide, and cystatin C predict risk of death, cardiovascular disease, HF, and dementia; (2) higher levels of cardiovascular disease biomarkers are associated with increased risk of HF and then secondary increased risk of dementia; and (3) risk of dementia is lower among participants with a combination of lower coronary artery calcium, atherosclerosis, and lower high-sensitivity cardiac troponin T (myocardial injury). The Cardiovascular Health Study Cognition Study was a continuation of the Cardiovascular Health Study limited to the Pittsburgh, PA, center from 1998-1999 to 2014. In 1992-1994, 924 participants underwent magnetic resonance imaging of the brain. There were 199 deaths and 116 developed dementia before 1998-1999. Of the 609 participants eligible for the Pittsburgh Cardiovascular Health Study Cognition Study, 87.5% (n=532) were included in the study. There were 120 incident HF cases and 72% had dementia. In 80 of 87, dementia preceded HF. A combination of low coronary artery calcium score and low high-sensitivity cardiac troponin T was significantly associated with reduced risk of dementia and HF. Most participants with HF had dementia but with onset before HF. Lower high-sensitivity cardiac troponin T and coronary artery calcium was associated with low risk of dementia based on a small number of events. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00005133. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  6. Rational clinical evaluation of suspected acute coronary syndromes: The value of more information.

    PubMed

    Hancock, David G; Chuang, Ming-Yu Anthony; Bystrom, Rebecca; Halabi, Amera; Jones, Rachel; Horsfall, Matthew; Cullen, Louise; Parsonage, William A; Chew, Derek P

    2017-12-01

    Many meta-analyses have provided synthesised likelihood ratio data to aid clinical decision-making. However, much less has been published on how to safely combine clinical information in practice. We aimed to explore the benefits and risks of pooling clinical information during the ED assessment of suspected acute coronary syndrome. Clinical information on 1776 patients was collected within a randomised trial conducted across five South Australian EDs between July 2011 and March 2013. Bayes theorem was used to calculate patient-specific post-test probabilities using age- and gender-specific pre-test probabilities and likelihood ratios corresponding to the presence or absence of 18 clinical factors. Model performance was assessed as the presence of adverse cardiac outcomes among patients theoretically discharged at a post-test probability less than 1%. Bayes theorem-based models containing high-sensitivity troponin T (hs-troponin) outperformed models excluding hs-troponin, as well as models utilising TIMI and GRACE scores. In models containing hs-troponin, a plateau in improving discharge safety was observed after the inclusion of four clinical factors. Models with fewer clinical factors better approximated the true event rate, tended to be safer and resulted in a smaller standard deviation in post-test probability estimates. We showed that there is a definable point where additional information becomes uninformative and may actually lead to less certainty. This evidence supports the concept that clinical decision-making in the assessment of suspected acute coronary syndrome should be focused on obtaining the least amount of information that provides the highest benefit for informing the decisions of admission or discharge. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  7. A clinical score to obviate the need for cardiac stress testing in patients with acute chest pain and negative troponins.

    PubMed

    Bouzas-Mosquera, Alberto; Peteiro, Jesús; Broullón, Francisco J; Álvarez-García, Nemesio; Maneiro-Melón, Nicolás; Pardo-Martinez, Patricia; Sagastagoitia-Fornie, Marta; Martínez, Dolores; Yáñez, Juan C; Vázquez-Rodríguez, José Manuel

    2016-08-01

    Although cardiac stress testing may help establish the safety of early discharge in patients with suspected acute coronary syndromes and negative troponins, more cost-effective strategies are necessary. We aimed to develop a clinical prediction rule to safely obviate the need for cardiac stress testing in this setting. A decision rule was derived in a prospective cohort of 3001 patients with acute chest pain and negative troponins, and validated in a set of 1473 subjects. The primary end point was a composite of positive cardiac stress testing (in the absence of a subsequent negative coronary angiogram), positive coronary angiography, or any major coronary events within 3 months. A score chart was built based on 7 variables: male sex (+2), age (+1 per decade from the fifth decade), diabetes mellitus (+2), hypercholesterolemia (+1), prior coronary revascularization (+2), type of chest pain (typical angina, +5; non-specific chest pain, -3), and non-diagnostic repolarization abnormalities (+2). In the validation set, the model showed good discrimination (c statistic = 0.84; 95% confidence interval, 0.82-0.87) and calibration (Hosmer-Lemeshow goodness-of-fit test, P= .34). If stress tests were avoided in patients in the validation sample with a sum score of 0 or lower, the number of referrals would be reduced by 23.4%, yielding a negative predictive value of 98.8% (95% confidence interval, 97.0%-99.7%). This novel prediction rule based on a combination of readily available clinical characteristics may be a valuable tool to decide whether stress testing can be reliably avoided in patients with acute chest pain and negative troponins. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Detection of high-sensitivity troponin in outpatients with stable pulmonary hypertension identifies a subgroup at higher risk of adverse outcomes.

    PubMed

    Roy, Andrew K; McCullagh, Brian N; Segurado, Ricardo; McGorrian, Catherine; Keane, Elizabeth; Keaney, John; Fitzgibbon, Maria N; Mahon, Niall G; Murray, Patrick T; Gaine, Sean P

    2014-01-01

    The detection of elevations in cardiorenal biomarkers, such as troponins, B-type natriuretic peptides (BNPs), and neutrophil gelatinase-associated lipocalins, are associated with poor outcomes in patients hospitalized with acute heart failure. Less is known about the association of these markers with adverse events in chronic right ventricular dysfunction due to pulmonary hypertension, or whether their measurement may improve risk assessment in the outpatient setting. We performed a cohort study of 108 patients attending the National Pulmonary Hypertension Unit in Dublin, Ireland, from 2007 to 2009. Cox proportional hazards analysis and receiver operating characteristic curves were used to determine predictors of mortality and hospitalization. Death or hospitalization occurred in 50 patients (46.3%) during the median study period of 4.1 years. Independent predictors of mortality were: 1) decreasing 6-minute walk test (6MWT; hazard ratio [HR] 12.8; P < .001); 2) BNP (HR 6.68; P < .001); and 3) highly sensitive troponin (hsTnT; HR 5.48; P < .001). Adjusted hazard analyses remained significant when hsTnT was added to a model with BNP and 6MWT (HR 9.26, 95% CI 3.61-23.79), as did the predictive ability of the model for death and rehospitalization (area under the receiver operating characteristic curve 0.81, 95% CI 0.73-0.90). Detection of troponin using a highly sensitive assay identifies a pulmonary hypertension subgroup with a poorer prognosis. hsTnT may also be used in a risk prediction model to identify patients at higher risk who may require escalation of targeted pulmonary vasodilator therapies and closer clinical surveillance. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform.

    PubMed

    Huang, Jian; Walcott, Gregory P; Ruse, Richard B; Bohanan, Scott J; Killingsworth, Cheryl R; Ideker, Raymond E

    2012-09-11

    We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.

  10. Biologic variability in NT-proBNP and cardiac troponin-I in healthy dogs and dogs with mitral valve degeneration.

    PubMed

    Ruaux, Craig; Scollan, Katherine; Suchodolski, Jan S; Steiner, Jörg M; Sisson, D David

    2015-09-01

    The N-terminal fragment of the prohormone B-type natriuretic peptide (NT-proBNP) and cardiac troponin-I are candidate biomarkers for cardiac disease in dogs. The degree of biologic variation in these biomarkers has not previously been reported in healthy dogs or dogs with mitral regurgitation. The purpose of the study was to derive estimates of intrinsic biologic variability and reference change values for NT-proBNP and cardiac troponin-I in healthy dogs and dogs with mitral regurgitation grade IB and II according to the International Small Animal Cardiac Health Council (ISACHC) grading system. Plasma and sera were collected weekly for up to 7 weeks from 12 control dogs and 9 dogs with mitral regurgitation. NT-proBNP and troponin-I (C-TnI) concentrations were determined. Indices of biologic variation such as reciprocal index of individuality (r-IoI) and reference change values (RCV) were calculated in both the groups. Individuality was high in control dogs and dogs with grade IB and II mitral valve regurgitation for both C-TnI (r-IoI 1.6 and 2) and NT-proBNP (1.5 and 2.7), while the 2-sided RCV for NT-proBNP was significantly lower in dogs with mitral regurgitation (52.5% vs 99.4%, P<0.01.). High individuality of these cardiac biomarkers suggests that, following diagnosis, these assays are best interpreted by serial determination in individual canine patients rather than by comparison to a population-based reference interval. The smaller RCV values for dogs with mitral regurgitation suggest that smaller relative changes in NT-proBNP are clinically meaningful in these patients. © 2015 American Society for Veterinary Clinical Pathology.

  11. Effect of Hypertrophic Cardiomyopathy-Linked Troponin C Mutations on the Response of Reconstituted Thin Filaments to Calcium upon Troponin I Phosphorylation†

    PubMed Central

    Albury, Acchia N. J.; Swindle, Nicholas; Swartz, Darl R.; Tikunova, Svetlana B.

    2012-01-01

    The objective of this work was to investigate the effect of hypertrophic cardiomyopathy-linked A8V and E134D mutations in cardiac troponin C (cTnC) on the response of reconstituted thin filaments to calcium upon phosphorylation of cardiac troponin I (cTnI) by protein kinase A. The phosphorylation of cTnI at protein kinase A sites was mimicked by S22D/S23D mutation in cTnI. Our results demonstrate that the A8V and E134D mutations had no effect on the extent of calcium desensitization of reconstituted thin filaments induced by cTnI pseudo-phosphorylation. However, the A8V mutation enhanced the effect of cTnI pseudo-phosphorylation on the rate of calcium dissociation from reconstituted thin filaments and on calcium dependence of actomyosin ATPase. Consequently, while the A8V mutation still led to a slower rate of calcium dissociation from reconstituted thin filaments upon pseudo-phosphorylation of cTnI, the ability of the A8V mutation to decrease the rate of calcium dissociation was diminished. In addition, the ability of the A8V mutation to sensitize actomyosin ATPase to calcium was diminished after cTnI was replaced by the phosphorylation mimetic of cTnI. Consistent with the hypothesis that the E134D mutation is benign, it exerted minor to no effect on the rate of calcium dissociation from reconstituted thin filaments, and on calcium sensitivity of actomyosin ATPase, regardless of cTnI phosphorylation status. In conclusion, our study enhances understanding of how cardiomyopathy-linked cTnC mutations affect the response of reconstituted thin filaments to calcium upon cTnI phosphorylation. PMID:22489623

  12. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy (ECT)

    PubMed Central

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A.; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J. Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B.; Zorumski, Charles F.; Conway, Charles; Nagele, Peter

    2017-01-01

    Background While electroconvulsive therapy (ECT) is widely regarded as a life-saving and safe procedure, evidence regarding its effects on myocardial cell injury are sparse. The objective of this investigation was to determine incidence and magnitude of new cardiac troponin elevation after ECT using a novel high-sensitivity cardiac troponin I (hscTnI) assay. Methods This was a prospective cohort study in adult patients undergoing ECT in a single academic center (up to three ECT treatments per patient). The primary outcome was new hscTnI elevation after ECT, defined as an increase of hscTnI >100% after ECT compared to baseline with at least one value above the limit of quantification (10 ng/L). 12-lead ECG and hscTnI values were obtained prior to and 15–30 minutes after ECT; in a subset of patients an additional 2-hour hscTnI value was obtained. Results The final study population was 100 patients and a total of 245 ECT treatment sessions. Eight patients (8/100, 8%) experienced new hscTnI elevation after ECT with a cumulative incidence of 3.7% (9/245 treatments; one patient had two hscTnI elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2/245, 0.8%). Median hscTnI concentrations did not increase significantly after ECT. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of ECT treatments. Conclusions ECT appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with pre-existing cardiovascular risk factors, however, may develop new cardiac troponin elevation after ECT, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia. PMID:28166110

  13. Safety of a rapid diagnostic protocol with accelerated stress testing.

    PubMed

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  14. Cardiac troponin T determination by a highly sensitive assay in postmortem serum and pericardial fluid.

    PubMed

    González-Herrera, Lucas; Valenzuela, Aurora; Ramos, Valentín; Blázquez, Antonia; Villanueva, Enrique

    2016-06-01

    The main objective of this study was to test, for the first time, a highly sensitive cardiac troponin T (cTnThs) assay in postmortem serum and pericardial fluid and to evaluate cardiac troponin T (cTnT) levels and their stability after death at different postmortem intervals, in an attempt to determine the viability of the cTnThs assay in the postmortem diagnosis of the cause of death. cTnT levels were determined in serum and pericardial fluid samples taken from 58 cadavers at known postmortem intervals, whose causes of death were categorized into the following groups: (1) sudden cardiac deaths, (2) multiple trauma, (3) mechanical asphyxia, and (4) other natural deaths. cTnT was determined by inmunoassay, using the Troponin T highly sensitive STAT assay (Roche(®)). Average cTnT levels measured by a highly sensitive assay in postmortem serum were markedly higher than clinical serum levels. Moreover, similar results, higher cTnT levels in postmortem pericardial fluid, were obtained when compared to levels found in pericardial fluid taken from two living patients during coronary artery bypass surgery. cTnT levels in both postmortem fluids remained stable for up to 34 h after death. No differences in cTnT levels in either postmortem fluid by sex and age were detected. Levels of cTnT found in pericardial fluid in the other natural deaths group were significantly lower than the cTnT levels found in that postmortem fluid from any of the other causes of death groups. It is therefore reasonable to conclude that determination of cTnT by a highly sensitive assay in pericardial fluid can provide forensic pathologists with a complementary test to the diagnosis of cause of death.

  15. Use of a highly-sensitive cardiac troponin I assay in a screening population for hypertrophic cardiomyopathy: a case-referent study.

    PubMed

    McGorrian, Catherine M; Lyster, Sarah; Roy, Andrew; Tarrant, Heloise; Codd, Mary; Doran, Peter; Fitzgibbon, Maria; Galvin, Joseph; Mahon, Niall G

    2013-09-11

    Hypertrophic cardiomyopathy (HCM) is a genetic condition, and relatives of affected persons may be at risk. Cardiac troponin biomarkers have previously been shown to be elevated in HCM. This study examines the new highly-sensitive cardiac troponin I (hsTnI) assay in a HCM screening population. Nested case-control study of consecutive HCM sufferers and their relatives recruited from May 2010 to September 2011. After informed consent, participants provided venous blood samples and clinical and echocardiographic features were recorded. Associations between the natural log (ln) of the contemporary troponin I (cTnI) and hsTnI assays and markers of cardiac hypertrophy were examined. Multiple regression models were fitted to examine the predictive ability of hsTnI for borderline or definite HCM. Of 107 patients, 24 had borderline and 19 had definite changes of HCM. Both TnI assays showed significant, positive correlations with measures of cardiac muscle mass. After age and sex adjustment, the area under the receiver operator characteristic (AUROC) curve for the outcome of HCM was 0.78, 95% CI [0.65, 0.90], for ln(hsTnI), and 0.66, 95% CI [0.51, 0.82], for ln(cTnI) (p=0.11). Including the hsTnI assay in a multiple-adjusted "screening" model for HCM resulted in a non-significant improvement in both the AUROC and integrated discrimination index. Both cTnI and hsTnI show a graded, positive association with measures of cardiac muscle mass in persons at risk of HCM. Further studies will be required to evaluate the utility of these assays in ECG- and symptom-based identification of HCM in at-risk families.

  16. Serial measurements of high sensitive cardiac troponin I in patients with acutely decompensated heart failure treated with carperitide or nitrates.

    PubMed

    Sato, Yukihito; Nishi, Kiyoto; Saijo, Sayaka; Tanada, Yohei; Goto, Taisuke; Takahashi, Naoki; Yamamoto, Erika; Fukuhara, Rei; Miyamoto, Tadashi; Taniguchi, Ryoji; Fujiwara, Hisayoshi; Takatsu, Yoshiki

    2010-07-01

    In patients with acutely decompensated heart failure (ADHF), elevated serum concentration of cardiac troponin is an independent predictor of adverse cardiac events. In ADHF with a preserved systolic blood pressure, treatment with intravenous vasodilator is recommended. However, the effect of vasodilators on troponin concentrations has not been elucidated well. Serial high sensitive cardiac troponin I (hs-TnI) was measured in 36 patients presenting with ADHF and preserved systolic blood pressure, of whom 20 were treated with atrial natriuretic peptide (ANP) and 16 with nitrates. The concentrations of hs-TnI ranged from 0.069+/-0.114ng/ml at baseline to 0.076+/-0.121ng/ml at 5h, 0.062+/-0.106ng/ml at 1 day, and 0.056+/-0.089ng/ml at day 7 (n=36,ns). The relative change in hs-TnI between baseline and at 5h, day 1 and day 7 were 1.13+/-0.43, 0.95+/-0.44 and 0.93+/-0.64 in patients treated with ANP, and 1.02+/-0.19, 0.95+/-0.31 and 1.19+/-1.38 in patients treated with nitrates (ns; ANP versus nitrates). On day 7, a hs-TnI change, >20% decrease from baseline, was observed in 55% patients with ANP versus 56% patients with nitrates (ns). The cardiac event rates were similar in both groups. In ADHF patients with preserved systolic blood pressure, the administration of intravenous vasodilators did not decrease hs-TnI over the first 7 days. Treatments with ANP and nitrates were associated with similar short-term decreases in hs-TnI and long-term adverse cardiac events. Copyright 2010 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  17. Decreasing troponin turnaround time in the emergency department using the central laboratory: A process improvement study.

    PubMed

    Boelstler, Arlene M; Rowland, Ralph; Theoret, Jennifer; Takla, Robert B; Szpunar, Susan; Patel, Shraddha P; Lowry, Andrew M; Pena, Margarita E

    2015-03-01

    To implement collaborative process improvement measures to reduce emergency department (ED) troponin turnaround time (TAT) to less than 60min using central laboratory. This was an observational, retrospective data study. A multidisciplinary team from the ED and laboratory identified opportunities and developed a new workflow model. Process changes were implemented in ED patient triage, staffing, lab collection and processing. Data collected included TAT of door-to-order, order-to-collect, collect-to-received, received-to-result, door-to-result, ED length of stay, and hemolysis rate before (January-August, 2011) and after (September 2011-June 2013) process improvement. After process improvement and implementation of the new workflow model, decreased median TAT (in min) was seen in door-to-order (54 [IQR43] vs. 11 [IQR20]), order-to-collect (15 [IQR 23] vs. 10 [IQR12]), collect-to-received (6 [IQR8] vs. 5 [IQR5]), received-to-result (30 [IQR12] vs. 24 [IQR11]), and overall door-to-result (117 [IQR60] vs. 60 [IQR40]). A troponin TAT of <60min was realized beginning in May 2012 (59 [IQR39]). Hemolysis rates decreased (14.63±0.74 vs. 3.36±1.99, p<0.0001), as did ED length of stay (5.87±2.73h vs. 5.15±2.34h, p<0.0001). Conclusion Troponin TAT of <60min using a central laboratory was achieved with collaboration between the ED and the laboratory; additional findings include a decreased ED length of stay. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Time course of degradation of cardiac troponin I in patients with acute ST-elevation myocardial infarction: the ASSENT-2 troponin substudy.

    PubMed

    Madsen, Lene H; Christensen, Geir; Lund, Terje; Serebruany, Victor L; Granger, Chris B; Hoen, Ingvild; Grieg, Zanina; Alexander, John H; Jaffe, Allan S; Van Eyk, Jennifer E; Atar, Dan

    2006-11-10

    Although measurement of troponin is widely used for diagnosing acute myocardial infarction (AMI), its diagnostic potential may be increased by a more complete characterization of its molecular appearance and degradation in the blood. The aim of this study was to define the time course of cardiac troponin I (cTnI) degradation in patients with acute ST-elevation myocardial infarction (STEMI). In the ASSENT-2 substudy, 26 males hospitalized with STEMI were randomized to 2 different thrombolytic drugs within 6 hours after onset of symptoms. Blood samples were obtained just before initiation of thrombolysis and at 30 minutes intervals (7 samples per patient). Western blot analysis was performed using anti-cTnI antibodies and compared with serum concentrations of cTnI. All patients exceeded the cTnI cutoff for AMI during the sampling period; at initiation of therapy, 23 had elevated cTnI values. All patients demonstrated 2 bands on immunoblot: intact cTnI and a single degradation product as early as 90 minutes after onset of symptoms. On subsequent samples, 15 of 26 patients showed multiple degradation products with up to 7 degradation bands. The appearance of fragments was correlated with higher levels of cTnI (P<0.001) and time to initiation of treatment (P=0.058). This study defines for the first time the initial time course of cTnI degradation in STEMI. Intact cTnI and a single degradation product were detectable on immunoblot as early as 90 minutes after onset of symptoms with further degradation after 165 minutes. Infarct size and time to initiation of treatment was the major determinant for degradation.

  19. Clinical impact of a high-sensitivity troponin assay introduction on patients presenting to the emergency department.

    PubMed

    Peck, Daniel; Knott, Jonathan; Lefkovits, Jeffrey

    2016-06-01

    Biomarkers are a critical component in the investigation of patients with potential ischaemic heart disease. The proposed benefits of a high-sensitivity troponin (hs-Tn) assay include earlier diagnosis of myocardial infarction. However, the decreased specificity may adversely affect clinical practice. The present study aims to investigate the impact that the introduction of a hs-Tn assay had on patients presenting to the ED. A pre- and post-interventional analysis was performed on all patients presenting to the Royal Melbourne Hospital ED, and had a troponin, in the 12 months before and after the introduction of the hs-Tn assay. The main outcome measures were ED length of stay, admission rates, proportion of patients undergoing interventional cardiac procedures and proportion diagnosed with myocardial infarction. There were 6557 patients who had a conventional assay and 7335 patients who had a hs-Tn assay. The introduction of a hs-Tn assay was associated with an increased abnormal troponin rate (23.4% vs 28.1%, P < 0.001). The median length of ED stay decreased by 9.1% (P < 0.001). The proportion admitted to hospital increased (60.9% vs 65.9%, P < 0.001); however, there was no difference in the proportion undergoing revascularisation or the proportion diagnosed with myocardial infarction. Although the introduction of a hs-Tn assay led to an increase in hospital admissions, the unchanged rate of cardiac procedures or final diagnoses of acute myocardial infarction and ischaemic heart disease suggests that the hs-Tn did not improve the detection of these conditions. It remains unclear whether there was a benefit admitting the additional cohort of patients. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  20. Template-Based Modeling of Protein-RNA Interactions.

    PubMed

    Zheng, Jinfang; Kundrotas, Petras J; Vakser, Ilya A; Liu, Shiyong

    2016-09-01

    Protein-RNA complexes formed by specific recognition between RNA and RNA-binding proteins play an important role in biological processes. More than a thousand of such proteins in human are curated and many novel RNA-binding proteins are to be discovered. Due to limitations of experimental approaches, computational techniques are needed for characterization of protein-RNA interactions. Although much progress has been made, adequate methodologies reliably providing atomic resolution structural details are still lacking. Although protein-RNA free docking approaches proved to be useful, in general, the template-based approaches provide higher quality of predictions. Templates are key to building a high quality model. Sequence/structure relationships were studied based on a representative set of binary protein-RNA complexes from PDB. Several approaches were tested for pairwise target/template alignment. The analysis revealed a transition point between random and correct binding modes. The results showed that structural alignment is better than sequence alignment in identifying good templates, suitable for generating protein-RNA complexes close to the native structure, and outperforms free docking, successfully predicting complexes where the free docking fails, including cases of significant conformational change upon binding. A template-based protein-RNA interaction modeling protocol PRIME was developed and benchmarked on a representative set of complexes.

  1. Simulation-based comprehensive benchmarking of RNA-seq aligners

    PubMed Central

    Baruzzo, Giacomo; Hayer, Katharina E; Kim, Eun Ji; Di Camillo, Barbara; FitzGerald, Garret A; Grant, Gregory R

    2018-01-01

    Alignment is the first step in most RNA-seq analysis pipelines, and the accuracy of downstream analyses depends heavily on it. Unlike most steps in the pipeline, alignment is particularly amenable to benchmarking with simulated data. We performed a comprehensive benchmarking of 14 common splice-aware aligners for base, read, and exon junction-level accuracy and compared default with optimized parameters. We found that performance varied by genome complexity, and accuracy and popularity were poorly correlated. The most widely cited tool underperforms for most metrics, particularly when using default settings. PMID:27941783

  2. Hyperfine-Structure-Induced Depolarization of Impulsively Aligned I2 Molecules

    NASA Astrophysics Data System (ADS)

    Thomas, Esben F.; Søndergaard, Anders A.; Shepperson, Benjamin; Henriksen, Niels E.; Stapelfeldt, Henrik

    2018-04-01

    A moderately intense 450 fs laser pulse is used to create rotational wave packets in gas phase I2 molecules. The ensuing time-dependent alignment, measured by Coulomb explosion imaging with a delayed probe pulse, exhibits the characteristic revival structures expected for rotational wave packets but also a complex nonperiodic substructure and decreasing mean alignment not observed before. A quantum mechanical model attributes the phenomena to coupling between the rotational angular momenta and the nuclear spins through the electric quadrupole interaction. The calculated alignment trace agrees very well with the experimental results.

  3. An accelerated diagnostic protocol for the early, safe discharge of low-risk chest pain patients.

    PubMed

    Altherwi, Tawfeeq; Grad, Willis B

    2015-07-01

    Can an accelerated 2-hour diagnostic protocol using the cardiac troponin I (cTnI) measurement as the only biomarker be implemented to allow an earlier and safe discharge of low-risk chest pain patients? Than M, Cullen L, Aldous S, et al. 2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial. J Am Coll Cardiol 2012;59(23):2091-8. To determine whether an accelerated diagnostic protocol (ADP) for possible cardiac chest pain could identify low-risk patients suitable for early discharge using cTnI as the sole biomarker.

  4. The quality of laboratory aspects of troponin testing in clinical practice guidelines and consensus documents needs to be improved.

    PubMed

    Aakre, Kristin M; Langlois, Michel R; Barth, Julian H; Misra, Shivani; Watine, Joseph; Oosterhuis, Wytze P

    2014-11-01

    The European Federation of Laboratory Medicine (EFLM) and the Union of European Medical Specialists (UEMS) joint Working Group on guidelines recently proposed a checklist to help standardize the description of laboratory investigations in clinical practice guidelines (CPG). Nine CPGs or consensus documents published from 2011 to 2013 describing the investigation of chest pain, diagnosis of acute coronary syndrome, or myocardial infarction were evaluated against the published checklist. Clinical use of troponin analysis are commonly dealt with but the publications present variable, vague and sometimes conflicting information regarding this laboratory test being very much relied on upon making a diagnosis of acute coronary syndrome. Most of the laboratory related checklist items are not considered or need to be updated e.g. suggested analytical quality goals are not applicable for the high sensitive assays and important interferences that may lead to false positive or negative diagnoses are commonly not mentioned. The current paper sums up important analytical and biological issues related to troponin assays and gives suggestions for analytical quality goals that could be included in CPG's. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. CRYO-EM STRUCTURES OF THE ACTIN:TROPOMYOSIN FILAMENT REVEAL THE MECHANISM FOR THE TRANSITION FROM C- TO M-STATE

    PubMed Central

    Sousa, Duncan R.; Stagg, Scott M.; Stroupe, M. Elizabeth

    2013-01-01

    Tropomyosin is a key factor in the molecular mechanisms that regulate the binding of myosin motors to actin filaments in most eukaryotic cells. This regulation is achieved by the azimuthal repositioning of tropomyosin along the actin:tropomyosin:troponin thin filament to block or expose myosin binding sites on actin. In striated muscle, including involuntary cardiac muscle, tropomyosin regulates muscle contraction by coupling Ca2+ binding to troponin with myosin binding to the thin filament. In smooth muscle, the switch is the post-translational modification of the myosin. Depending on the activation state of troponin and the binding state of myosin, tropomyosin can occupy the blocked, closed, or open position on actin. Using native cryogenic 3DEM, we have directly resolved and visualized cardiac and gizzard muscle tropomyosin on filamentous actin in the position that corresponds to the closed state. From the 8-Å resolution structure of the reconstituted Ac:Tm filament formed with gizzard-derived Tm we discuss two possible mechanisms for the transition from closed to open state and describe the role Tm plays in blocking myosin tight binding in the closed state position. PMID:24021812

  6. Effects of metoprolol therapy on cardiac troponin-I levels after elective percutaneous coronary interventions.

    PubMed

    Atar, Ilyas; Korkmaz, Mehmet Emin; Atar, Inci Asli; Gulmez, Oyku; Ozin, Bulent; Bozbas, Huseyin; Erol, Tansel; Aydinalp, Alp; Yildirir, Aylin; Yucel, Muammer; Muderrisoglu, Haldun

    2006-03-01

    Beta-blockers (BBs) have been shown to improve survival and reduce the risk of re-infarction in patients following myocardial infarction. There are conflicting data about the effects of BB therapy on cardiac biomarkers after percutaneous coronary interventions (PCIs). The aim of the study was to investigate the effects of BB use on cardiac troponin-I (cTnI) levels in patients who had undergone elective PCI. In this prospective study, 287 patients with coronary artery disease were included. Patients were randomized either to BB or control groups prior to the intervention. Blood samples for cTnI were obtained before and at 6, 24, and 36 h after the procedure. Of the 287 patients included, 143 received metoprolol succinate 100 mg/day, and 144 received no BB and served as the control group. Baseline clinical characteristics of both groups, except for history of coronary artery bypass graft surgery, were similar. We observed no significant difference in the elevation of cTnI levels between the two groups after PCI (BB group, 17 patients, 11.9%; control group, 10 patients, 6.9%; P=0.2). Metoprolol succinate therapy seems to have no cardioprotective effect in limiting troponin-I rise after PCI.

  7. Highly Sensitive Troponin I Followed by Advanced Coronary Artery Disease Assessment Using Computed Tomography Angiography Improves Acute Coronary Syndrome Risk Stratification Accuracy and Work-up in Acute Chest Pain Patients: Results from ROMICAT II Trial

    PubMed Central

    Mayrhofer, Thomas; Puchner, Stefan B.; Lu, Michael T.; Maurovich-Horvat, Pal; Pope, J. Hector; Truong, Quynh A.; Udelson, James E.; Peacock, W. Frank; White, Charles S.; Woodard, Pamela K.; Fleg, Jerome L.; Nagurney, John T.; Januzzi, James L.; Hoffmann, Udo

    2015-01-01

    Objectives We compared diagnostic accuracy of conventional troponin/traditional coronary artery disease (CAD) assessment and highly sensitive troponin (hsTn) I/advanced CAD assessment for acute coronary syndrome (ACS) during the index hospitalization. Background HsTn I and advanced assessment of CAD using coronary computed tomography angiography (CTA) are promising candidates to improve the accuracy of emergency department (ED) evaluation of patients with suspected ACS. Methods We performed an observational cohort study in patients with suspected ACS enrolled in the ROMICAT II trial and randomized to coronary CTA who also had hsTn I measurement at the time of the ED presentation. We assessed coronary CTA for traditional (no CAD, non-obstructive CAD, ≥50% stenosis) and advanced features of CAD (≥50% stenosis, high-risk plaque features: positive remodeling, low <30 Hounsfield Units plaque, napkin ring sign, spotty calcium). Results Of 160 patients (mean age: 53±8 years, 40% women) 10.6% were diagnosed with ACS. The ACS rate in patients with HsTn I below the limit of detection (n=9, 5.6%), intermediate (n=139, 86.9%), and above the 99th percentile (n=12, 7.5%) was 0%, 8.6%, and 58.3%, respectively. Absence of ≥50% stenosis and high-risk plaque ruled out ACS in patients with intermediate hsTn I (n=87, 54.4%; ACS rate 0%), while patients with both ≥50% stenosis and high-risk plaque were at high risk (n=13, 8.1%; ACS rate 69.2%) and patients with either ≥50% stenosis or high-risk plaque were at intermediate risk for ACS (n=39, 24.4%; ACS rate 7.7%). HsTn I/advanced coronary CTA assessment significantly improved the diagnostic accuracy for ACS as compared to conventional troponin/traditional coronary CTA (AUC 0.84, 95%CI 0.80-0.88 vs. 0.74, 95%CI 0.70-0.78; p<0.001). Conclusions HsTn I at the time of presentation followed by early advanced coronary CTA assessment improves the risk stratification and diagnostic accuracy for ACS as compared to conventional troponin and traditional coronary CTA assessment. (Multicenter Study to Rule Out Myocardial Infarction/Ischemia by Cardiac Computed Tomography [ROMICAT-II]; NCT01084239) PMID:26476506

  8. Agreement in electrocardiogram interpretation in patients with septic shock.

    PubMed

    Mehta, Sangeeta; Granton, John; Lapinsky, Stephen E; Newton, Gary; Bandayrel, Kristofer; Little, Anjuli; Siau, Chuin; Cook, Deborah J; Ayers, Dieter; Singer, Joel; Lee, Terry C; Walley, Keith R; Storms, Michelle; Cooper, Jamie; Holmes, Cheryl L; Hebert, Paul; Gordon, Anthony C; Presneill, Jeff; Russell, James A

    2011-09-01

    The reliability of electrocardiogram interpretation to diagnose myocardial ischemia in critically ill patients is unclear. In adults with septic shock, we assessed intra- and inter-rater agreement of electrocardiogram interpretation, and the effect of knowledge of troponin values on these interpretations. Prospective substudy of a randomized trial of vasopressin vs. norepinephrine in septic shock. Nine Canadian intensive care units. Adults with septic shock requiring at least 5 μg/min of norepinephrine for 6 hrs. Twelve-lead electrocardiograms were recorded before study drug, and 6 hrs, 2 days, and 4 days after study drug initiation. Two physician readers, blinded to patient data and group, independently interpreted electrocardiograms on three occasions (first two readings were blinded to patient data; third reading was unblinded to troponin). To calibrate and refine definitions, both readers initially reviewed 25 trial electrocardiograms representing normal to abnormal. Cohen's Kappa and the φ statistic were used to analyze intra- and inter-rater agreement. One hundred twenty-one patients (62.2 ± 16.5 yrs, Acute Physiology and Chronic Health Evaluation II 28.6 ± 7.7) had 373 electrocardiograms. Blinded to troponin, readers 1 and 2 interpreted 46.4% and 30.0% of electrocardiograms as normal, and 15.3% and 12.3% as ischemic, respectively. Intrarater agreement was moderate for overall ischemia (κ 0.54 and 0.58), moderate/good for "normal" (κ 0.69 and 0.55), fair to good for specific signs of ischemia (ST elevation, T inversion, and Q waves, reader 1 κ 0.40 to 0.69; reader 2 κ 0.56 to 0.70); and good/very good for atrial arrhythmias (κ 0.84 and 0.79) and bundle branch block (κ 0.88 and 0.79). Inter-rater agreement was fair for ischemia (κ 0.29), moderate for ST elevation (κ 0.48), T inversion (κ 0.52), and Q waves (κ 0.44), good for bundle branch block (κ 0.78), and very good for atrial arrhythmias (κ 0.83). Inter-rater agreement for ischemia improved from fair to moderate (κ 0.52, p = .028) when unblinded to troponin. In patients with septic shock, inter-rater agreement of electrocardiogram interpretation for myocardial ischemia was fair, and improved with troponin knowledge.

  9. Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.

    PubMed

    Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H

    2018-05-13

    Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common challenges included concerns over POCT accuracy (32%), and technical barriers (29%). In the study ED, implementation of POCT was associated with a reduction in time to test result for both troponin and chemistry. Local staff felt that faster time to test result improved quality of care; however, concerns were raised with POCT accuracy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Troponin T and NT ProBNP Levels in Gestational, Type 1 and Type 2 Diabetic Mothers and Macrosomic Infants.

    PubMed

    Mert, Mustafa Kurthan; Satar, Mehmet; Özbarlas, Nazan; Yaman, Akgün; Özgünen, Fatma Tuncay; Asker, Hüseyin Selim; Çekinmez, Eren Kale; Tetiker, Tamer

    2016-01-01

    This study compares NT proBNP and troponin T levels in umbilical cord arterial blood and postnatal echocardiographic findings for infants of gestational and pregestational diabetic mothers and macrosomic infants. Twenty-seven infants of pregestational diabetic mothers, 61 infants of gestational diabetic mothers and 37 macrosomic infants of nondiabetic mothers were prospectively enrolled in this study along with a control group of 58 healthy infants of mothers without any pregestational or gestational disorders as the control group. All enrollees were born after 34 weeks of gestation. For this study, umbilical cord blood was drawn during delivery to determine NT proBNP and troponin T levels. Echocardiography was performed 24-72 h after the delivery. Umbilical cord troponin T and NT proBNP levels were found to be higher in the diabetic and macrosomic groups than in the control group (all of them p < 0.001). NT proBNP levels were positively correlated with interventricular septum thickness in the pregestational and gestational infants of diabetic mothers groups (r = 0.564 and r = 0.560, respectively, p < 0.01). Both pregestational and gestational diabetic mothers were divided into two groups according to HbA1c levels in the third trimester as good (<6.1 %) and suboptimal (>6.1 %) metabolic control. In the good and suboptimal metabolic control diabetic groups, NT proBNP levels were also positively correlated with interventricular septum thickness (r = 0.536 and r = 0.576, respectively, p < 0.01). In the suboptimal metabolic control diabetic group, NT proBNP was only found to be positively correlated with the left ventricular mass index (r = 0.586, p < 0.01). While there was no correlation in the myocardial performance index between infants of diabetic mothers and the control group, the myocardial performance index of macrosomic infants was lower than that of the control group (p = 0.017). Cardiac biomarkers (NT proBNP and troponin T) were elevated in infants of diabetic mothers and macrosomic infants. While there was a positive correlation between NT proBNP levels and cardiac structure in infants of pregestational and gestational diabetic mothers, there was no relationship between NT proBNP levels and cardiac function.

  11. Triangular Alignment (TAME). A Tensor-based Approach for Higher-order Network Alignment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohammadi, Shahin; Gleich, David F.; Kolda, Tamara G.

    2015-11-01

    Network alignment is an important tool with extensive applications in comparative interactomics. Traditional approaches aim to simultaneously maximize the number of conserved edges and the underlying similarity of aligned entities. We propose a novel formulation of the network alignment problem that extends topological similarity to higher-order structures and provide a new objective function that maximizes the number of aligned substructures. This objective function corresponds to an integer programming problem, which is NP-hard. Consequently, we approximate this objective function as a surrogate function whose maximization results in a tensor eigenvalue problem. Based on this formulation, we present an algorithm called Triangularmore » AlignMEnt (TAME), which attempts to maximize the number of aligned triangles across networks. We focus on alignment of triangles because of their enrichment in complex networks; however, our formulation and resulting algorithms can be applied to general motifs. Using a case study on the NAPABench dataset, we show that TAME is capable of producing alignments with up to 99% accuracy in terms of aligned nodes. We further evaluate our method by aligning yeast and human interactomes. Our results indicate that TAME outperforms the state-of-art alignment methods both in terms of biological and topological quality of the alignments.« less

  12. Accelerating large-scale protein structure alignments with graphics processing units

    PubMed Central

    2012-01-01

    Background Large-scale protein structure alignment, an indispensable tool to structural bioinformatics, poses a tremendous challenge on computational resources. To ensure structure alignment accuracy and efficiency, efforts have been made to parallelize traditional alignment algorithms in grid environments. However, these solutions are costly and of limited accessibility. Others trade alignment quality for speedup by using high-level characteristics of structure fragments for structure comparisons. Findings We present ppsAlign, a parallel protein structure Alignment framework designed and optimized to exploit the parallelism of Graphics Processing Units (GPUs). As a general-purpose GPU platform, ppsAlign could take many concurrent methods, such as TM-align and Fr-TM-align, into the parallelized algorithm design. We evaluated ppsAlign on an NVIDIA Tesla C2050 GPU card, and compared it with existing software solutions running on an AMD dual-core CPU. We observed a 36-fold speedup over TM-align, a 65-fold speedup over Fr-TM-align, and a 40-fold speedup over MAMMOTH. Conclusions ppsAlign is a high-performance protein structure alignment tool designed to tackle the computational complexity issues from protein structural data. The solution presented in this paper allows large-scale structure comparisons to be performed using massive parallel computing power of GPU. PMID:22357132

  13. Multi-scale continuum modeling of biological processes: from molecular electro-diffusion to sub-cellular signaling transduction

    NASA Astrophysics Data System (ADS)

    Cheng, Y.; Kekenes-Huskey, P.; Hake, J. E.; Holst, M. J.; McCammon, J. A.; Michailova, A. P.

    2012-01-01

    This paper presents a brief review of multi-scale modeling at the molecular to cellular scale, with new results for heart muscle cells. A finite element-based simulation package (SMOL) was used to investigate the signaling transduction at molecular and sub-cellular scales (http://mccammon.ucsd.edu/smol/, http://FETK.org) by numerical solution of the time-dependent Smoluchowski equations and a reaction-diffusion system. At the molecular scale, SMOL has yielded experimentally validated estimates of the diffusion-limited association rates for the binding of acetylcholine to mouse acetylcholinesterase using crystallographic structural data. The predicted rate constants exhibit increasingly delayed steady-state times, with increasing ionic strength, and demonstrate the role of an enzyme's electrostatic potential in influencing ligand binding. At the sub-cellular scale, an extension of SMOL solves a nonlinear, reaction-diffusion system describing Ca2+ ligand buffering and diffusion in experimentally derived rodent ventricular myocyte geometries. Results reveal the important role of mobile and stationary Ca2+ buffers, including Ca2+ indicator dye. We found that alterations in Ca2+-binding and dissociation rates of troponin C (TnC) and total TnC concentration modulate sub-cellular Ca2+ signals. The model predicts that reduced off-rate in the whole troponin complex (TnC, TnI, TnT) versus reconstructed thin filaments (Tn, Tm, actin) alters cytosolic Ca2+ dynamics under control conditions or in disease-linked TnC mutations. The ultimate goal of these studies is to develop scalable methods and theories for the integration of molecular-scale information into simulations of cellular-scale systems.

  14. Desktop aligner for fabrication of multilayer microfluidic devices.

    PubMed

    Li, Xiang; Yu, Zeta Tak For; Geraldo, Dalton; Weng, Shinuo; Alve, Nitesh; Dun, Wu; Kini, Akshay; Patel, Karan; Shu, Roberto; Zhang, Feng; Li, Gang; Jin, Qinghui; Fu, Jianping

    2015-07-01

    Multilayer assembly is a commonly used technique to construct multilayer polydimethylsiloxane (PDMS)-based microfluidic devices with complex 3D architecture and connectivity for large-scale microfluidic integration. Accurate alignment of structure features on different PDMS layers before their permanent bonding is critical in determining the yield and quality of assembled multilayer microfluidic devices. Herein, we report a custom-built desktop aligner capable of both local and global alignments of PDMS layers covering a broad size range. Two digital microscopes were incorporated into the aligner design to allow accurate global alignment of PDMS structures up to 4 in. in diameter. Both local and global alignment accuracies of the desktop aligner were determined to be about 20 μm cm(-1). To demonstrate its utility for fabrication of integrated multilayer PDMS microfluidic devices, we applied the desktop aligner to achieve accurate alignment of different functional PDMS layers in multilayer microfluidics including an organs-on-chips device as well as a microfluidic device integrated with vertical passages connecting channels located in different PDMS layers. Owing to its convenient operation, high accuracy, low cost, light weight, and portability, the desktop aligner is useful for microfluidic researchers to achieve rapid and accurate alignment for generating multilayer PDMS microfluidic devices.

  15. Desktop aligner for fabrication of multilayer microfluidic devices

    PubMed Central

    Li, Xiang; Yu, Zeta Tak For; Geraldo, Dalton; Weng, Shinuo; Alve, Nitesh; Dun, Wu; Kini, Akshay; Patel, Karan; Shu, Roberto; Zhang, Feng; Li, Gang; Jin, Qinghui; Fu, Jianping

    2015-01-01

    Multilayer assembly is a commonly used technique to construct multilayer polydimethylsiloxane (PDMS)-based microfluidic devices with complex 3D architecture and connectivity for large-scale microfluidic integration. Accurate alignment of structure features on different PDMS layers before their permanent bonding is critical in determining the yield and quality of assembled multilayer microfluidic devices. Herein, we report a custom-built desktop aligner capable of both local and global alignments of PDMS layers covering a broad size range. Two digital microscopes were incorporated into the aligner design to allow accurate global alignment of PDMS structures up to 4 in. in diameter. Both local and global alignment accuracies of the desktop aligner were determined to be about 20 μm cm−1. To demonstrate its utility for fabrication of integrated multilayer PDMS microfluidic devices, we applied the desktop aligner to achieve accurate alignment of different functional PDMS layers in multilayer microfluidics including an organs-on-chips device as well as a microfluidic device integrated with vertical passages connecting channels located in different PDMS layers. Owing to its convenient operation, high accuracy, low cost, light weight, and portability, the desktop aligner is useful for microfluidic researchers to achieve rapid and accurate alignment for generating multilayer PDMS microfluidic devices. PMID:26233409

  16. Inflight alignment of payload inertial reference from Shuttle navigation system

    NASA Astrophysics Data System (ADS)

    Treder, A. J.; Norris, R. E.; Ruprecht, R.

    Two methods for payload attitude initialization from the STS Orbiter have been proposed: body axis maneuvers (BAM) and star line maneuvers (SLM). The first achieves alignment directly through the Shuttle star tracker, while the second, indirectly through the stellar-updated Shuttle inertial platform. The Inertial Upper Stage (IUS) with its strapdown navigation system is used to demonstrate in-flight alignment techniques. Significant accuracy can be obtained with minimal impact on Orbiter operations, with payload inertial reference potentially approaching the accuracy of the Shuttle star tracker. STS-6 flight performance parameters, including alignment stability, are discussed and compared with operational complexity. Results indicate overall alignment stability of .06 deg, 3 sigma per axis.

  17. Automation of the targeting and reflective alignment concept

    NASA Technical Reports Server (NTRS)

    Redfield, Robin C.

    1992-01-01

    The automated alignment system, described herein, employs a reflective, passive (requiring no power) target and includes a PC-based imaging system and one camera mounted on a six degree of freedom robot manipulator. The system detects and corrects for manipulator misalignment in three translational and three rotational directions by employing the Targeting and Reflective Alignment Concept (TRAC), which simplifies alignment by decoupling translational and rotational alignment control. The concept uses information on the camera and the target's relative position based on video feedback from the camera. These relative positions are converted into alignment errors and minimized by motions of the robot. The system is robust to exogenous lighting by virtue of a subtraction algorithm which enables the camera to only see the target. These capabilities are realized with relatively minimal complexity and expense.

  18. Interdisciplinary Exploration Supports Sternberg's Expansion of Giftedness

    ERIC Educational Resources Information Center

    Ambrose, Don

    2017-01-01

    Robert Sternberg's (2017) Active Concerned Citizenship and Ethical Leadership (ACCEL) framework provides a helpful way to align gifted education with the complexities of 21st-century socioeconomic and cultural environments. The recommendation that we shift away from pseudoquantitative precision in conceptions of giftedness aligns with similar…

  19. Alignment of RNA molecules: Binding energy and statistical properties of random sequences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valba, O. V., E-mail: valbaolga@gmail.com; Nechaev, S. K., E-mail: sergei.nechaev@gmail.com; Tamm, M. V., E-mail: thumm.m@gmail.com

    2012-02-15

    A new statistical approach to the problem of pairwise alignment of RNA sequences is proposed. The problem is analyzed for a pair of interacting polymers forming an RNA-like hierarchical cloverleaf structures. An alignment is characterized by the numbers of matches, mismatches, and gaps. A weight function is assigned to each alignment; this function is interpreted as a free energy taking into account both direct monomer-monomer interactions and a combinatorial contribution due to formation of various cloverleaf secondary structures. The binding free energy is determined for a pair of RNA molecules. Statistical properties are discussed, including fluctuations of the binding energymore » between a pair of RNA molecules and loop length distribution in a complex. Based on an analysis of the free energy per nucleotide pair complexes of random RNAs as a function of the number of nucleotide types c, a hypothesis is put forward about the exclusivity of the alphabet c = 4 used by nature.« less

  20. OPTIMA: sensitive and accurate whole-genome alignment of error-prone genomic maps by combinatorial indexing and technology-agnostic statistical analysis.

    PubMed

    Verzotto, Davide; M Teo, Audrey S; Hillmer, Axel M; Nagarajan, Niranjan

    2016-01-01

    Resolution of complex repeat structures and rearrangements in the assembly and analysis of large eukaryotic genomes is often aided by a combination of high-throughput sequencing and genome-mapping technologies (for example, optical restriction mapping). In particular, mapping technologies can generate sparse maps of large DNA fragments (150 kilo base pairs (kbp) to 2 Mbp) and thus provide a unique source of information for disambiguating complex rearrangements in cancer genomes. Despite their utility, combining high-throughput sequencing and mapping technologies has been challenging because of the lack of efficient and sensitive map-alignment algorithms for robustly aligning error-prone maps to sequences. We introduce a novel seed-and-extend glocal (short for global-local) alignment method, OPTIMA (and a sliding-window extension for overlap alignment, OPTIMA-Overlap), which is the first to create indexes for continuous-valued mapping data while accounting for mapping errors. We also present a novel statistical model, agnostic with respect to technology-dependent error rates, for conservatively evaluating the significance of alignments without relying on expensive permutation-based tests. We show that OPTIMA and OPTIMA-Overlap outperform other state-of-the-art approaches (1.6-2 times more sensitive) and are more efficient (170-200 %) and precise in their alignments (nearly 99 % precision). These advantages are independent of the quality of the data, suggesting that our indexing approach and statistical evaluation are robust, provide improved sensitivity and guarantee high precision.

  1. Development and application of an algorithm to compute weighted multiple glycan alignments.

    PubMed

    Hosoda, Masae; Akune, Yukie; Aoki-Kinoshita, Kiyoko F

    2017-05-01

    A glycan consists of monosaccharides linked by glycosidic bonds, has branches and forms complex molecular structures. Databases have been developed to store large amounts of glycan-binding experiments, including glycan arrays with glycan-binding proteins. However, there are few bioinformatics techniques to analyze large amounts of data for glycans because there are few tools that can handle the complexity of glycan structures. Thus, we have developed the MCAW (Multiple Carbohydrate Alignment with Weights) tool that can align multiple glycan structures, to aid in the understanding of their function as binding recognition molecules. We have described in detail the first algorithm to perform multiple glycan alignments by modeling glycans as trees. To test our tool, we prepared several data sets, and as a result, we found that the glycan motif could be successfully aligned without any prior knowledge applied to the tool, and the known recognition binding sites of glycans could be aligned at a high rate amongst all our datasets tested. We thus claim that our tool is able to find meaningful glycan recognition and binding patterns using data obtained by glycan-binding experiments. The development and availability of an effective multiple glycan alignment tool opens possibilities for many other glycoinformatics analysis, making this work a big step towards furthering glycomics analysis. http://www.rings.t.soka.ac.jp. kkiyoko@soka.ac.jp. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press.

  2. Current development in microfluidic immunosensing chip.

    PubMed

    Henares, Terence G; Mizutani, Fumio; Hisamoto, Hideaki

    2008-03-17

    This review accounts for the current development in microfluidic immunosensing chips. The basic knowledge of immunoassay in relation to its microfluidic material substrate, fluid handling and detection mode are briefly discussed. Here, we mainly focused on the surface modification, antibody immobilization, detection, signal enhancement and multiple analyte sensing. Some of the clinically important currently implemented on the microfluidic immunoassay chips are C-reactive protein (CRP), prostate specific antigen (PSA), ferritin, vascular endothelial growth factor (VEGF), myoglobin (Myo), cardiac troponin T (cTnT), cardiac troponin I (cTnI), and creatine kinase-cardiac muscle isoform (CK-MB). The emerging microfludic immunosensor technology may be a promising prospect that can propel the improvement of clinical and medical diagnosis.

  3. Improving scanner wafer alignment performance by target optimization

    NASA Astrophysics Data System (ADS)

    Leray, Philippe; Jehoul, Christiane; Socha, Robert; Menchtchikov, Boris; Raghunathan, Sudhar; Kent, Eric; Schoonewelle, Hielke; Tinnemans, Patrick; Tuffy, Paul; Belen, Jun; Wise, Rich

    2016-03-01

    In the process nodes of 10nm and below, the patterning complexity along with the processing and materials required has resulted in a need to optimize alignment targets in order to achieve the required precision, accuracy and throughput performance. Recent industry publications on the metrology target optimization process have shown a move from the expensive and time consuming empirical methodologies, towards a faster computational approach. ASML's Design for Control (D4C) application, which is currently used to optimize YieldStar diffraction based overlay (DBO) metrology targets, has been extended to support the optimization of scanner wafer alignment targets. This allows the necessary process information and design methodology, used for DBO target designs, to be leveraged for the optimization of alignment targets. In this paper, we show how we applied this computational approach to wafer alignment target design. We verify the correlation between predictions and measurements for the key alignment performance metrics and finally show the potential alignment and overlay performance improvements that an optimized alignment target could achieve.

  4. Rapid Quantification of 3D Collagen Fiber Alignment and Fiber Intersection Correlations with High Sensitivity

    PubMed Central

    Sun, Meng; Bloom, Alexander B.; Zaman, Muhammad H.

    2015-01-01

    Metastatic cancers aggressively reorganize collagen in their microenvironment. For example, radially orientated collagen fibers have been observed surrounding tumor cell clusters in vivo. The degree of fiber alignment, as a consequence of this remodeling, has often been difficult to quantify. In this paper, we present an easy to implement algorithm for accurate detection of collagen fiber orientation in a rapid pixel-wise manner. This algorithm quantifies the alignment of both computer generated and actual collagen fiber networks of varying degrees of alignment within 5°°. We also present an alternative easy method to calculate the alignment index directly from the standard deviation of fiber orientation. Using this quantitative method for determining collagen alignment, we demonstrate that the number of collagen fiber intersections has a negative correlation with the degree of fiber alignment. This decrease in intersections of aligned fibers could explain why cells move more rapidly along aligned fibers than unaligned fibers, as previously reported. Overall, our paper provides an easier, more quantitative and quicker way to quantify fiber orientation and alignment, and presents a platform in studying effects of matrix and cellular properties on fiber alignment in complex 3D environments. PMID:26158674

  5. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    PubMed

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Red blood cells aligning inside innovative liquid crystal cell

    NASA Astrophysics Data System (ADS)

    Likhomanova, S. V.; Kamanin, A. A.; Kamanina, N. V.

    2017-11-01

    Investigation results of red blood cells (human erythrocytes) aligning and fixing inside the liquid crystal (LC) cell have been presented in the present paper. LC cells have been modified through the improved nanostructured relief and LC sensitized with intermolecular charge transfer complex COANP-C70.

  7. Template-Based Modeling of Protein-RNA Interactions

    PubMed Central

    Zheng, Jinfang; Kundrotas, Petras J.; Vakser, Ilya A.

    2016-01-01

    Protein-RNA complexes formed by specific recognition between RNA and RNA-binding proteins play an important role in biological processes. More than a thousand of such proteins in human are curated and many novel RNA-binding proteins are to be discovered. Due to limitations of experimental approaches, computational techniques are needed for characterization of protein-RNA interactions. Although much progress has been made, adequate methodologies reliably providing atomic resolution structural details are still lacking. Although protein-RNA free docking approaches proved to be useful, in general, the template-based approaches provide higher quality of predictions. Templates are key to building a high quality model. Sequence/structure relationships were studied based on a representative set of binary protein-RNA complexes from PDB. Several approaches were tested for pairwise target/template alignment. The analysis revealed a transition point between random and correct binding modes. The results showed that structural alignment is better than sequence alignment in identifying good templates, suitable for generating protein-RNA complexes close to the native structure, and outperforms free docking, successfully predicting complexes where the free docking fails, including cases of significant conformational change upon binding. A template-based protein-RNA interaction modeling protocol PRIME was developed and benchmarked on a representative set of complexes. PMID:27662342

  8. Alignment hierarchies: engineering architecture from the nanometre to the micrometre scale.

    PubMed

    Kureshi, Alvena; Cheema, Umber; Alekseeva, Tijna; Cambrey, Alison; Brown, Robert

    2010-12-06

    Natural tissues are built of metabolites, soluble proteins and solid extracellular matrix components (largely fibrils) together with cells. These are configured in highly organized hierarchies of structure across length scales from nanometre to millimetre, with alignments that are dominated by anisotropies in their fibrillar matrix. If we are to successfully engineer tissues, these hierarchies need to be mimicked with an understanding of the interaction between them. In particular, the movement of different elements of the tissue (e.g. molecules, cells and bulk fluids) is controlled by matrix structures at distinct scales. We present three novel systems to introduce alignment of collagen fibrils, cells and growth factor gradients within a three-dimensional collagen scaffold using fluid flow, embossing and layering of construct. Importantly, these can be seen as different parts of the same hierarchy of three-dimensional structure, as they are all formed into dense collagen gels. Fluid flow aligns collagen fibrils at the nanoscale, embossed topographical features provide alignment cues at the microscale and introducing layered configuration to three-dimensional collagen scaffolds provides microscale- and mesoscale-aligned pathways for protein factor delivery as well as barriers to confine protein diffusion to specific spatial directions. These seemingly separate methods can be employed to increase complexity of simple extracellular matrix scaffolds, providing insight into new approaches to directly fabricate complex physical and chemical cues at different hierarchical scales, similar to those in natural tissues.

  9. Node fingerprinting: an efficient heuristic for aligning biological networks.

    PubMed

    Radu, Alex; Charleston, Michael

    2014-10-01

    With the continuing increase in availability of biological data and improvements to biological models, biological network analysis has become a promising area of research. An emerging technique for the analysis of biological networks is through network alignment. Network alignment has been used to calculate genetic distance, similarities between regulatory structures, and the effect of external forces on gene expression, and to depict conditional activity of expression modules in cancer. Network alignment is algorithmically complex, and therefore we must rely on heuristics, ideally as efficient and accurate as possible. The majority of current techniques for network alignment rely on precomputed information, such as with protein sequence alignment, or on tunable network alignment parameters, which may introduce an increased computational overhead. Our presented algorithm, which we call Node Fingerprinting (NF), is appropriate for performing global pairwise network alignment without precomputation or tuning, can be fully parallelized, and is able to quickly compute an accurate alignment between two biological networks. It has performed as well as or better than existing algorithms on biological and simulated data, and with fewer computational resources. The algorithmic validation performed demonstrates the low computational resource requirements of NF.

  10. Cardiovascular biomarkers and sex: the case for women.

    PubMed

    Daniels, Lori B; Maisel, Alan S

    2015-10-01

    Measurement of biomarkers is a critical component of cardiovascular care. Women and men differ in their cardiac physiology and manifestations of cardiovascular disease. Although most cardiovascular biomarkers are used by clinicians without taking sex into account, sex-specific differences in biomarkers clearly exist. Baseline concentrations of many biomarkers (including cardiac troponin, natriuretic peptides, galectin-3, and soluble ST2) differ in men versus women, but these sex-specific differences do not generally translate into a need for differential sex-based cut-off points. Furthermore, most biomarkers are similarly diagnostic and prognostic, regardless of sex. Two potential exceptions are cardiac troponins measured by high-sensitivity assay, and proneurotensin. Troponin levels are lower in women than in men and, with the use of high-sensitivity assays, sex-specific cut-off points might improve the diagnosis of myocardial infarction. Proneurotensin is a novel biomarker that was found to be predictive of incident cardiovascular disease in women, but not men, and was also predictive of incident breast cancer. If confirmed, proneurotensin might be a unique biomarker of disease risk in women. With any biomarker, an understanding of sex-specific differences might improve its use and might also lead to an enhanced understanding of the physiological differences between the hearts of men and women.

  11. Diagnostic value of mean platelet volume (MPV) to troponin T inpatients with acute coronary syndrome

    NASA Astrophysics Data System (ADS)

    Aryanto, D.; Isnanta, R.; Safri, Z.; Hasan, R.

    2018-03-01

    Acute Coronary Syndrome (ACS) is used to describe the spectrum of coronary artery disease (CAD). Troponin T is the determinant of the most sensitive marker of ACS, but there aren’t all hospitals have this because of expensiveness. Mean Platelet Volume (MPV) is one of the components of a complete blood routine examination and relatively cheap as a marker in ACS. Determining the sensitivity and specificity of MPV in detecting cases of the acute coronary syndrome, 325 subjects’ medical records were from the period of July 2013 to June 2014; 228 ACS patients met the inclusion criteria. 228 subjects showed a risk factor for age ≥45years of more 195 (85.5%). 122 subjects with hypertension (53.5%) and subjects who smoked 118 (51.8%) that suffered most ACS. Subjects with risk factors for diabetes mellitus, obesity, menopause and dyslipidemia in this study was lower than non-diabetic 161 (70.6%), obese189 (82.9%), nonmenopause 196 (86%) and normal lipid 210 (92.1%). But there was norelation between risk factor with MPV and troponin T statistically. The results of diagnostic tests MPV for the evaluation of patients with ACS, sensitivity 92%, specificity 71%, positive predictive value 95% and negative predictive value 58%.

  12. Ultrasensitive cardiac troponin I antibody based nanohybrid sensor for rapid detection of human heart attack.

    PubMed

    Bhatnagar, Deepika; Kaur, Inderpreet; Kumar, Ashok

    2017-02-01

    An ultrasensitive cardiac troponin I antibody conjugated with graphene quantum dots (GQD) and polyamidoamine (PAMAM) nanohybrid modified gold electrode based sensor was developed for the rapid detection of heart attack (myocardial infarction) in human. Screen printed gold (Au) electrode was decorated with 4-aminothiophenol for amine functionalization of the Au surface. These amino groups were further coupled with carboxyl functionalities of GQD with EDC-NHS reaction. In order to enhance the sensitivity of the sensor, PAMAM dendrimer was successively embedded on GQD through carbodiimide coupling to provide ultra-high surface area for antibody immobilization. The activated cardiac troponin I (cTnI) monoclonal antibody was immobilized on PAMAM to form nanoprobe for sensing specific heart attack marker cTnI. Various concentrations of cardiac marker, cTnI were electrochemically measured using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in human blood serum. The modifications on sensor surface were characterized by FTIR and AFM techniques. The sensor is highly specific to cTnI and showed negligible response to non-specific antigens. The sensitivity of the sensor was 109.23μAcm -2 μg -1 and lower limit of detection of cTnI was found 20fgmL -1 . Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Sex-based differences in plasma chemistry and cardiac marker test results in Siamese fighting fowl.

    PubMed

    Sribhen, Choosri; Choothesa, Apassara; Songserm, Thaveesak; Issariyodom, Supaporn; Sribhen, Kosit

    2006-09-01

    Variations in the results of plasma chemistry analysis as a function of sex have rarely been demonstrated in avian species. The aim of the present study was to investigate sex-related differences in values for routine biochemical variables, including conventional muscle enzymes, and novel cardiac markers in female and male Siamese fighting fowl. Plasma chemistry analytes and cardiac marker proteins (creatine kinase-MB and cardiac troponin T) were measured in 70 Siamese fighting fowl using automated chemistry and immunoassay analyzers. Data were compared by 2-tailed t tests between sexes, and Spearman rank correlation between conventional and novel cardiac markers. Male fowl had significantly higher uric acid concentration and gamma-glutamyltransferase activity; whereas, female fowl had significantly higher total cholesterol, triglycerides, and calcium concentrations, and alkaline phosphatase activity. As compared with female fowl, the fighting cocks also had significantly higher plasma concentrations of creatine kinase-MB and cardiac troponin T. Significant correlations between cardiac troponin T, but not creatine kinase-MB, and the activities of conventional muscle enzymes (creatine kinase, aspartate aminotransferase and lactate dehydrogenase) were observed in male but not in female fowl. These results indicate that sex-specific differences exist for several biochemical parameters and cardiac marker proteins in fighting fowl, and that such differences should be considered in interpreting laboratory test results.

  14. Single histidine button in cardiac troponin I sustains heart performance in response to severe hypercapnic respiratory acidosis in vivo.

    PubMed

    Palpant, Nathan J; D'Alecy, Louis G; Metzger, Joseph M

    2009-05-01

    Intracellular acidosis is a profound negative regulator of myocardial performance. We hypothesized that titrating myofilament calcium sensitivity by a single histidine substituted cardiac troponin I (A164H) would protect the whole animal physiological response to acidosis in vivo. To experimentally induce severe hypercapnic acidosis, mice were exposed to a 40% CO(2) challenge. By echocardiography, it was found that systolic function and ventricular geometry were maintained in cTnI A164H transgenic (Tg) mice. By contrast, non-Tg (Ntg) littermates experienced rapid and marked cardiac decompensation during this same challenge. For detailed hemodymanic assessment, Millar pressure-conductance catheterization was performed while animals were treated with a beta-blocker, esmolol, during a severe hypercapnic acidosis challenge. Survival and load-independent measures of contractility were significantly greater in Tg vs. Ntg mice. This assay showed that Ntg mice had 100% mortality within 5 min of acidosis. By contrast, systolic and diastolic function were protected in Tg mice during acidosis, and they had 100% survival. This study shows that, independent of any beta-adrenergic compensation, myofilament-based molecular manipulation of inotropy by histidine-modified troponin I maintains cardiac inotropic and lusitropic performance and markedly improves survival during severe acidosis in vivo.

  15. An Evidence-Based Approach to the Assessment of Heart-Type Fatty Acid Binding Protein in Acute Coronary Syndrome

    PubMed Central

    Viswanathan, Karthik; Hall, Alistair S; Barth, Julian H

    2012-01-01

    Cardiac troponins have been the biomarkers of choice for the diagnosis of acute coronary syndrome (ACS) for over a decade. There has, however, been considerable interest over the last two decades for newer biomarkers that would bring added value to the measurement of troponin such as the provision of prognosis and assistance in the choice of therapeutic interventions. In this manuscript, we review the development of heart-type fatty acid binding protein (H-FABP) in patients with ACS using the evidence-based laboratory medicine format. Phase I studies have established that H-FABP reference intervals and pre-analytical factors influencing H-FABP. Phase II studies have confirmed a) that H-FABP is elevated in patients with established myocardial infarction; b) that its serum concentration is related to the extent of infarction using survival as a surrogate; and c) that its use in chest pain patients can identify ACS patients and also provide prognostic information on survival. Furthermore, it is an independent prognostic marker for patients with suspected ACS who are troponin negative. Phase III studies involving randomised control trials for diagnosis and prognosis have not yet been performed and Phase IV studies await uptake of H-FABP in a routine service. PMID:22363093

  16. Head-to-head comparison of the diagnostic performance of coronary computed tomography angiography and dobutamine-stress echocardiography in the evaluation of acute chest pain with normal ECG findings and negative troponin tests: A prospective multicenter study.

    PubMed

    Durand, Eric; Bauer, Fabrice; Mansencal, Nicolas; Azarine, Arshid; Diebold, Benoit; Hagege, Albert; Perdrix, Ludivine; Gilard, Martine; Jobic, Yannick; Eltchaninoff, Hélène; Bensalah, Mourad; Dubourg, Benjamin; Caudron, Jérôme; Niarra, Ralph; Chatellier, Gilles; Dacher, Jean-Nicolas; Mousseaux, Elie

    2017-08-15

    To perform a head-to-head comparison of coronary CT angiography (CCTA) and dobutamine-stress echocardiography (DSE) in patients presenting recent chest pain when troponin and ECG are negative. Two hundred seventeen patients with recent chest pain, normal ECG findings, and negative troponin were prospectively included in this multicenter study and were scheduled for CCTA and DSE. Invasive coronary angiography (ICA), was performed in patients when either DSE or CCTA was considered positive or when both were non-contributive or in case of recurrent chest pain during 6month follow-up. The presence of coronary artery stenosis was defined as a luminal obstruction >50% diameter in any coronary segment at ICA. ICA was performed in 75 (34.6%) patients. Coronary artery stenosis was identified in 37 (17%) patients. For CCTA, the sensitivity was 96.9% (95% CI 83.4-99.9), specificity 48.3% (29.4-67.5), positive likelihood ratio 2.06 (95% CI 1.36-3.11), and negative likelihood ratio 0.07 (95% CI 0.01-0.52). The sensitivity of DSE was 51.6% (95% CI 33.1-69.9), specificity 46.7% (28.3-65.7), positive likelihood ratio 1.03 (95% CI 0.62-1.72), and negative likelihood ratio 1.10 (95% CI 0.63-1.93). The CCTA: DSE ratio of true-positive and false-positive rates was 1.70 (95% CI 1.65-1.75) and 1.00 (95% CI 0.91-1.09), respectively, when non-contributive CCTA and DSE were both considered positive. Only one missed acute coronary syndrome was observed at six months. CCTA has higher diagnostic performance than DSE in the evaluation of patients with recent chest pain, normal ECG findings, and negative troponine to exclude coronary artery disease. Copyright © 2017. Published by Elsevier B.V.

  17. Lyme disease presenting with facial palsy and myocarditis mimicking myocardial infarction.

    PubMed

    Gilson, Julieta; Khalighi, Koroush; Elmi, Farhad; Krishnamurthy, Mahesh; Talebian, Amirsina; Toor, Rubinder S

    2017-01-01

    A 45-year-old woman presented with a sudden episode of typical chest pain, radiating to her neck. The patient denied premature coronary artery disease in the family. Initial EKG showed normal sinus rhythm with a 1 mm ST-elevation involving lead II and lead aVF and a 1 mm ST-depression in lead V1 with associated T-wave inversion. Initial Troponin I (normal <0.4 ng/mL) and CK-MB (normal <7.7 ng/mL) were elevated at 7.82 ng/mL and 55.2 ng/mL, respectively. Six hours later, Troponin I increased to 13.44 ng/mL and CK-MB to 75.7 ng/mL. The patient underwent cardiac catheterization which did not show any significant obstructive coronary artery disease. Two days later the patient developed right-sided facial palsy. Diagnosis of Lyme disease was confirmed by ELISA with positive IgM and IgG antibodies. Treatment with intravenous ceftriaxone and oral steroids was started. Eventually resolution of symptoms and, normalization of cardiac markers and EKG changes, were achieved. This is a rare case of Lyme myocarditis associated with markedly elevated Troponin I, normal left ventricle function, and an absence of conduction abnormalities. To the best of our knowledge, Lyme myocarditis mimicking acute coronary syndrome with such high levels of Troponin I and neurologic compromise has not been previously described. Lyme myocarditis may be a challenging diagnosis in endemic areas especially in patients with coronary artery disease risk factors, presenting with typical chest pain, EKG changes and positive cardiac biomarkers. Therefore, it should be considered a differential diagnosis in patients presenting with clinical symptoms suggestive of acute coronary syndrome. Abbreviations AV: Atrioventricular; CK-MB: Creatinine Kinase-MB; EKG: Electrocardiogram; ELISA: Enzyme-Linked Immunosorbent Assay; IgG: Immunoglobulin G; IgM: Immunoglobulin M.

  18. Elevated cardiac troponin T is associated with higher mortality and amputation rates in patients with peripheral arterial disease.

    PubMed

    Linnemann, Birgit; Sutter, Thilo; Herrmann, Eva; Sixt, Sebastian; Rastan, Aljoscha; Schwarzwaelder, Uwe; Noory, Elias; Buergelin, Karlheinz; Beschorner, Ulrich; Zeller, Thomas

    2014-04-22

    The aim of the present study was to evaluate whether elevated cardiac troponin T (cTnT) was independently associated with an increased all-cause mortality or risk of cardiovascular events and amputation among patients with peripheral arterial disease (PAD). PAD patients often have impaired renal function, and the blood concentration of cardiac troponin often increases with declining glomerular filtration rate. The cohort consisted of 1,041 consecutive PAD patients (653 males, 388 females, age 70.7 ± 10.8 years, Rutherford stages 2 to 5) undergoing endovascular peripheral revascularization. At baseline, measurable cTnT levels (≥0.01 ng/ml) were detected in 21.3% of individuals. Compared with patients who had undetectable cTnT levels, those with cTnT levels ≥0.01 ng/ml had higher rates for mortality (31.7% vs. 3.9%, respectively; p < 0.001), myocardial infarction (4.1% vs. 1.1%, respectively; p = 0.003), and amputation (10.1% vs. 2.4%, respectively; p < 0.001) during a 1-year follow-up. In adjusted Cox regression models, cTnT levels ≥0.01 ng/ml were associated with increased total mortality (hazard ratio [HR]: 8.14; 95% confidence interval [CI]: 3.77 to 17.6; p < 0.001) and amputation rates (HR: 3.71; 95% CI: 1.33 to 10.3; p = 0.012). cTnT is frequently elevated in PAD patients and is associated with higher event rates in terms of total mortality and amputation. Even small cTnT elevations predict a markedly increased risk that is independent of an impaired renal function. (Troponin T as Risk Stratification Tool in Patients With Peripheral Arterial Occlusive Disease; NCT01087385). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. The small-molecule fast skeletal troponin activator, CK-2127107, improves exercise tolerance in a rat model of heart failure.

    PubMed

    Hwee, Darren T; Kennedy, Adam R; Hartman, James J; Ryans, Julie; Durham, Nickie; Malik, Fady I; Jasper, Jeffrey R

    2015-04-01

    Heart failure-mediated skeletal myopathy, which is characterized by muscle atrophy and muscle metabolism dysfunction, often manifests as dyspnea and limb muscle fatigue. We have previously demonstrated that increasing Ca(2+) sensitivity of the sarcomere by a small-molecule fast skeletal troponin activator improves skeletal muscle force and exercise performance in healthy rats and models of neuromuscular disease. The objective of this study was to investigate the effect of a novel fast skeletal troponin activator, CK-2127107 (2-aminoalkyl-5-N-heteroarylpyrimidine), on skeletal muscle function and exercise performance in rats exhibiting heart failure-mediated skeletal myopathy. Rats underwent a left anterior descending coronary artery ligation, resulting in myocardial infarction and a progressive decline in cardiac function [left anterior descending coronary artery heart failure (LAD-HF)]. Compared with sham-operated control rats, LAD-HF rat hindlimb and diaphragm muscles exhibited significant muscle atrophy. Fatigability was increased during repeated in situ isokinetic plantar flexor muscle contractions. CK-2127107 produced a leftward shift in the force-Ca(2+) relationship of skinned, single diaphragm, and extensor digitorum longus fibers. Exercise performance, which was assessed by rotarod running, was lower in vehicle-treated LAD-HF rats than in sham controls (116 ± 22 versus 193 ± 31 seconds, respectively; mean ± S.E.M.; P = 0.04). In the LAD-HF rats, a single oral dose of CK-2127107 (10 mg/kg p.o.) increased running time compared with vehicle treatment (283 ± 47 versus 116 ± 22 seconds; P = 0.0004). In summary, CK-2127107 substantially increases exercise performance in this heart failure model, suggesting that modulation of skeletal muscle function by a fast skeletal troponin activator may be a useful therapeutic in heart failure-associated exercise intolerance. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.

  20. Incremental prognostic value of biomarkers beyond the GRACE (Global Registry of Acute Coronary Events) score and high-sensitivity cardiac troponin T in non-ST-elevation acute coronary syndrome.

    PubMed

    Widera, Christian; Pencina, Michael J; Bobadilla, Maria; Reimann, Ines; Guba-Quint, Anja; Marquardt, Ivonne; Bethmann, Kerstin; Korf-Klingebiel, Mortimer; Kempf, Tibor; Lichtinghagen, Ralf; Katus, Hugo A; Giannitsis, Evangelos; Wollert, Kai C

    2013-10-01

    Guidelines recommend the use of validated risk scores and a high-sensitivity cardiac troponin assay for risk assessment in non-ST-elevation acute coronary syndrome (NSTE-ACS). The incremental prognostic value of biomarkers in this context is unknown. We calculated the Global Registry of Acute Coronary Events (GRACE) score and measured the circulating concentrations of high-sensitivity cardiac troponin T (hs-cTnT) and 8 selected cardiac biomarkers on admission in 1146 patients with NSTE-ACS. We used an hs-cTnT threshold at the 99th percentile of a reference population to define increased cardiac marker in the score. The magnitude of the increase in model performance when individual biomarkers were added to GRACE was assessed by the change (Δ) in the area under the receiver-operating characteristic curve (AUC), integrated discrimination improvement (IDI), and category-free net reclassification improvement [NRI(>0)]. Seventy-eight patients reached the combined end point of 6-month all-cause mortality or nonfatal myocardial infarction. The GRACE score alone had an AUC of 0.749. All biomarkers were associated with the risk of the combined end point and offered statistically significant improvement in model performance when added to GRACE (likelihood ratio test P ≤ 0.015). Growth differentiation factor 15 [ΔAUC 0.039, IDI 0.049, NRI(>0) 0.554] and N-terminal pro-B-type natriuretic peptide [ΔAUC 0.024, IDI 0.027, NRI(>0) 0.438] emerged as the 2 most promising biomarkers. Improvements in model performance upon addition of a second biomarker were small in magnitude. Biomarkers can add prognostic information to the GRACE score even in the current era of high-sensitivity cardiac troponin assays. The incremental information offered by individual biomarkers varies considerably, however.

  1. Thermo-wrap technology preserves normothermia better than routine thermal care in patients undergoing off-pump coronary artery bypass and is associated with lower immune response and lesser myocardial damage.

    PubMed

    Nesher, Nahum; Uretzky, Gideon; Insler, Steven; Nataf, Patrick; Frolkis, Inna; Pineau, Emmanuelle; Cantoni, Emmanuel; Bolotin, Gil; Vardi, Moshe; Pevni, Dimitry; Lev-Ran, Oren; Sharony, Ram; Weinbroum, Avi A

    2005-06-01

    Perioperative hypothermia might be detrimental to the patient undergoing off-pump coronary artery bypass surgery. We assessed the efficacy of the Allon thermoregulation system (MTRE Advanced Technologies Ltd, Or-Akiva, Israel) compared with that of routine thermal care in maintaining normothermia during and after off-pump coronary artery bypass surgery. Patients undergoing off-pump coronary artery bypass surgery were perioperatively and randomly warmed with the 2 techniques (n = 45 per group). Core temperature, hemodynamics, and troponin I, interleukin 6, interleukin 8, and interleukin 10 blood levels were assessed. The mean temperature of the patients in the Allon thermoregulation system group (AT group) was significantly ( P < .005) higher than that of the patients receiving routine thermal care (the RTC group); less than 40% of the latter reached 36 degrees C compared with 100% of the former. The cardiac index was higher and the systemic vascular resistance was lower ( P < .05) by 16% and 25%, respectively, in the individuals in the AT group compared with in the individuals in the RTC group during the 4 postoperative hours. End-of-surgery interleukin 6 levels and 24-hour postoperative troponin I levels were significantly ( P < .01) lower in the patients in the AT group than in the RTC group. The RTC group's troponin levels closely correlated with their interleukin 6 levels at the end of the operation ( R = 0.51, P = .002). Unlike routine thermal care, the Allon thermoregulation system maintains core normothermia in more than 80% of patients undergoing off-pump coronary artery bypass surgery. Normothermia is associated with better cardiac and vascular conditions, a lower cardiac injury rate, and a lower inflammatory response. The close correlation between the increased interleukin 6 and troponin I levels in the routine thermal care group indicates a potential deleterious effect of lowered temperature on the patient's outcome.

  2. Cardiac Troponin Measurement in the Critically Ill: Potential for Guiding Clinical Management.

    PubMed

    Poe, Stacy; Vandivier-Pletsch, Robin H; Clay, Michael; Wong, Hector R; Haynes, Erin; Rothenberg, Florence G

    2015-12-01

    Elevated cardiac troponin (cTn) in the absence of acute coronary syndromes (ACS) is associated with increased mortality in critically ill patients. There are no evidence-based interventions that reduce mortality in this group. We performed a retrospective investigation of the Veterans Administration Inpatient Evaluation Center database to determine whether drugs used in ACS (β-blockers, aspirin, and statins) are associated with reduced mortality in critically ill patients. Thirty-day mortality was determined for non-ACS patients admitted to any Veterans Administration Intensive Care Unit between October 1, 2007, and September 30, 2008, adjusted for severity of illness. Troponin assay values were normalized across institutions. Multivariate analyses for 30-day mortality showed an odds ratio (OR) of 1.82 for patients with high cTn (P < 0.0001, cTn > 10% coefficient of variation) and 1.18 for intermediate cTn (P = 0.0021, cTn between lowest limit detectable and 10% coefficient of variation) compared with patients with no elevation, adjusting for severity of illness (n = 19,979). Logistic regression models showed that patients with no or intermediate elevations of cTn taking statins within 24 hours of cTn measurement had a lower mortality than patients not taking statins (OR, 0.66; 95% confidence interval [95% CI], 0.53-0.82; P = 0.0003), whereas patients with high cTn had a lower mortality if they were taking β-blockers or aspirin within 24 hours of cTn measurement compared to patients not taking β-blockers or aspirin (β-blockers: OR, 0.80; 95% CI, 0.68-0.94; P = 0.0077; aspirin: OR, 0.81;95% CI, 0.69-0.96; P = 0.0134). This retrospective study confirms an association between elevated troponin and outcomes in critically ill patients without ACS and identifies statins, β-blockers, and aspirin as potential outcome modifiers in a cTn-dependent manner.

  3. Prognostic Importance of Sex-Specific Cardiac Troponin T 99(th) Percentiles in Suspected Acute Coronary Syndrome.

    PubMed

    Eggers, Kai M; Jernberg, Tomas; Lindahl, Bertil

    2016-08-01

    Cardiac troponin levels differ between the sexes, with higher values commonly seen in men. The use of sex-specific troponin thresholds is, thus, subject of an ongoing debate. We assessed whether sex-specific cardiac troponin T (cTnT) 99(th) percentiles would improve risk prediction in patients admitted to Swedish coronary care units due to suspected acute coronary syndrome. In this retrospective register-based study (48,250 patients), we investigated the prediction of all-cause mortality and the composite of cardiovascular death or nonfatal myocardial infarction within 1 year using the single 99(th) cTnT percentile (>14 ng/L) or sex-specific cTnT 99(th) percentiles (>16/9 ng/L). A total of 1078 men (3.0%) with cTnT 15-16 ng/L and 1854 women (8.4%) with cTnT 10-14 ng/L would have been reclassified regarding their cTnT status by the means of sex-specific 99(th) percentiles. The prevalence of cardiovascular risk factors and crude event rates increased across higher cTnT strata in both men and women. Multivariable-adjusted Cox models, however, did not demonstrate better risk prediction by sex-specific 99(th) percentiles. Assessing cTnT as a continuous variable demonstrated an increase in multivariable-adjusted risk starting at levels around 10-12 ng/L in both men and women. We found no evidence supporting the use of sex-specific cTnT 99(th) percentiles in men and women admitted because of suspected acute coronary syndrome. This likely depends on sex-specific differences in disease mechanisms associated with small cTnT elevations. From a pragmatic perspective, a single cTnT cutoff slightly below 14 ng/L seems to be preferable as a threshold for medical decision-making. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Early Dynamic Risk Stratification with Baseline Troponin Levels and 90-minute ST Segment Resolution to Predict 30 Day Cardiovascular Mortality in STEMI: Analysis from CLARITY TIMI-28

    PubMed Central

    Sherwood, Matthew W.; Morrow, David A.; Scirica, Benjamin M.; Jiang, Songtao; Bode, Christoph; Rifai, Nader; Gerszten, Robert E.; Gibson, C. Michael; Cannon, Christopher P.; Braunwald, Eugene; Sabatine, Marc S.

    2010-01-01

    Background Troponin is the preferred biomarker for risk stratification in non-ST-elevation ACS. The incremental prognostic utility of the initial magnitude of troponin elevation and its value in conjunction with ST segment resolution (STRes) in STEMI is less well-defined. Methods Troponin T (TnT) was measured in 1250 patients at presentation undergoing fibrinolysis for STEMI in CLARITY-TIMI 28. STRes was measured at 90 minutes. Multivariable logistic regression was used to examine the independent association between TnT levels, STRes, and 30-day cardiovascular (CV) mortality. Results Patients were classified into undetectable TnT at baseline (n=594), detectable but below the median of 0.12 ng/ml (n=330), and above the median (n=326). Rates of 30-day CV death were 1.5%, 4.5%, and 9.5% respectively (P<0.0001). Compared with those with undetectable levels and adjusting for baseline factors, the odds ratios for 30-day CV death were 4.56 (1.72-12.08, P=0.002) and 5.81 (2.29-14.73, P=0.0002) for those below and above the median, respectively. When combined with STRes, there was a significant gradient of risk, and in a multivariable model both baseline TnT (P=0.004) and STRes (P=0.003) were significant predictors of 30-day CV death. The addition of TnT and STRes to clinical risk factors significantly improved the C-statistic (0.86 to 0.90, P=0.02) and the integrated discriminative improvement 7.1% (P=0.0009). Conclusions Baseline TnT and 90-minute STRes are independent predictors of 30-day CV death in patients with STEMI. Use of these two simple, readily available tools can aid clinicians in early risk stratification. PMID:20569707

  5. The twilight zone of cis element alignments.

    PubMed

    Sebastian, Alvaro; Contreras-Moreira, Bruno

    2013-02-01

    Sequence alignment of proteins and nucleic acids is a routine task in bioinformatics. Although the comparison of complete peptides, genes or genomes can be undertaken with a great variety of tools, the alignment of short DNA sequences and motifs entails pitfalls that have not been fully addressed yet. Here we confront the structural superposition of transcription factors with the sequence alignment of their recognized cis elements. Our goals are (i) to test TFcompare (http://floresta.eead.csic.es/tfcompare), a structural alignment method for protein-DNA complexes; (ii) to benchmark the pairwise alignment of regulatory elements; (iii) to define the confidence limits and the twilight zone of such alignments and (iv) to evaluate the relevance of these thresholds with elements obtained experimentally. We find that the structure of cis elements and protein-DNA interfaces is significantly more conserved than their sequence and measures how this correlates with alignment errors when only sequence information is considered. Our results confirm that DNA motifs in the form of matrices produce better alignments than individual sequences. Finally, we report that empirical and theoretically derived twilight thresholds are useful for estimating the natural plasticity of regulatory sequences, and hence for filtering out unreliable alignments.

  6. The twilight zone of cis element alignments

    PubMed Central

    Sebastian, Alvaro; Contreras-Moreira, Bruno

    2013-01-01

    Sequence alignment of proteins and nucleic acids is a routine task in bioinformatics. Although the comparison of complete peptides, genes or genomes can be undertaken with a great variety of tools, the alignment of short DNA sequences and motifs entails pitfalls that have not been fully addressed yet. Here we confront the structural superposition of transcription factors with the sequence alignment of their recognized cis elements. Our goals are (i) to test TFcompare (http://floresta.eead.csic.es/tfcompare), a structural alignment method for protein–DNA complexes; (ii) to benchmark the pairwise alignment of regulatory elements; (iii) to define the confidence limits and the twilight zone of such alignments and (iv) to evaluate the relevance of these thresholds with elements obtained experimentally. We find that the structure of cis elements and protein–DNA interfaces is significantly more conserved than their sequence and measures how this correlates with alignment errors when only sequence information is considered. Our results confirm that DNA motifs in the form of matrices produce better alignments than individual sequences. Finally, we report that empirical and theoretically derived twilight thresholds are useful for estimating the natural plasticity of regulatory sequences, and hence for filtering out unreliable alignments. PMID:23268451

  7. Phylogeny Reconstruction with Alignment-Free Method That Corrects for Horizontal Gene Transfer.

    PubMed

    Bromberg, Raquel; Grishin, Nick V; Otwinowski, Zbyszek

    2016-06-01

    Advances in sequencing have generated a large number of complete genomes. Traditionally, phylogenetic analysis relies on alignments of orthologs, but defining orthologs and separating them from paralogs is a complex task that may not always be suited to the large datasets of the future. An alternative to traditional, alignment-based approaches are whole-genome, alignment-free methods. These methods are scalable and require minimal manual intervention. We developed SlopeTree, a new alignment-free method that estimates evolutionary distances by measuring the decay of exact substring matches as a function of match length. SlopeTree corrects for horizontal gene transfer, for composition variation and low complexity sequences, and for branch-length nonlinearity caused by multiple mutations at the same site. We tested SlopeTree on 495 bacteria, 73 archaea, and 72 strains of Escherichia coli and Shigella. We compared our trees to the NCBI taxonomy, to trees based on concatenated alignments, and to trees produced by other alignment-free methods. The results were consistent with current knowledge about prokaryotic evolution. We assessed differences in tree topology over different methods and settings and found that the majority of bacteria and archaea have a core set of proteins that evolves by descent. In trees built from complete genomes rather than sets of core genes, we observed some grouping by phenotype rather than phylogeny, for instance with a cluster of sulfur-reducing thermophilic bacteria coming together irrespective of their phyla. The source-code for SlopeTree is available at: http://prodata.swmed.edu/download/pub/slopetree_v1/slopetree.tar.gz.

  8. Phylogeny Reconstruction with Alignment-Free Method That Corrects for Horizontal Gene Transfer

    PubMed Central

    Grishin, Nick V.; Otwinowski, Zbyszek

    2016-01-01

    Advances in sequencing have generated a large number of complete genomes. Traditionally, phylogenetic analysis relies on alignments of orthologs, but defining orthologs and separating them from paralogs is a complex task that may not always be suited to the large datasets of the future. An alternative to traditional, alignment-based approaches are whole-genome, alignment-free methods. These methods are scalable and require minimal manual intervention. We developed SlopeTree, a new alignment-free method that estimates evolutionary distances by measuring the decay of exact substring matches as a function of match length. SlopeTree corrects for horizontal gene transfer, for composition variation and low complexity sequences, and for branch-length nonlinearity caused by multiple mutations at the same site. We tested SlopeTree on 495 bacteria, 73 archaea, and 72 strains of Escherichia coli and Shigella. We compared our trees to the NCBI taxonomy, to trees based on concatenated alignments, and to trees produced by other alignment-free methods. The results were consistent with current knowledge about prokaryotic evolution. We assessed differences in tree topology over different methods and settings and found that the majority of bacteria and archaea have a core set of proteins that evolves by descent. In trees built from complete genomes rather than sets of core genes, we observed some grouping by phenotype rather than phylogeny, for instance with a cluster of sulfur-reducing thermophilic bacteria coming together irrespective of their phyla. The source-code for SlopeTree is available at: http://prodata.swmed.edu/download/pub/slopetree_v1/slopetree.tar.gz. PMID:27336403

  9. Aligning population-based care management with chronic disease complexity.

    PubMed

    Hewner, Sharon; Seo, Jin Young; Gothard, Sandra E; Johnson, Barbara J

    2014-01-01

    Risk-stratified care management requires knowledge of the complexity of chronic disease and comorbidity, information that is often not readily available in the primary care setting. The purpose of this article was to describe a population-based approach to risk-stratified care management that could be applied in primary care. Three populations (Medicaid, Medicare, and privately insured) at a regional health plan were divided into risk-stratified cohorts based on chronic disease and complexity, and utilization was compared before and after the implementation of population-specific care management teams of nurses. Risk-stratified care management was associated with reductions in hospitalization rates in all three populations, but the opportunities to avoid admissions were different. Knowledge of population complexity is critical to the development of risk-stratified care management in primary care, and a complexity matrix can help nurses identify gaps in care and align interventions to cohort and population needs. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Troponin T or troponin I or CK-MB (or none?).

    PubMed

    Collinson, P O

    1998-11-01

    Differential diagnosis of patients who present with chest pain remains problematical. It has been shown that 11.8-7% of patients with acute myocardial infarction (AMI) are sent home from the emergency department (ED). Audit of our own ED has shown the incidence of missed prognostically significant myocardial damage to be 6.7%. Diagnostic criteria for AMI have classically been based on the triad of history, ECG and measurement of cardiac enzymes. The choice of 'cardiac enzymes' has been dictated by the evolution of laboratory techniques, commencing with measurement of aspartate transaminase and progressing to measurement of creatine kinase (CK) and its MB isoenzyme (CK-MB). Measurement of CK-MB has been shown by both clinical studies and rigorous statistical analysis to represent the best test for the diagnosis of AMI. The advent of real time immunoassay together with advances in therapeutic options for management of acute coronary syndromes (ACS) has resulted in a paradigm shift in the approach to laboratory testing. Immunoassay for CK-MB (CK-MB mass measurement) is diagnostically superior to CK-MB activity measurement and is the test of choice for 'classical' AMI. Development of immunoassays for the cardiac troponins, i.e. cardiac troponin T (cTnT) and cardiac troponin I (cTnI), has enhanced diagnostic specificity. These measurements are completely specific for cardiac damage, allow quantitation of the extent of infarction and are diagnostically superior to CK-MB measurement. Applications of this specificity have included the differential diagnosis of CK elevation in arduous physical training, detection of myocardial damage after DC cardioversion and prediction of ejection fraction. Of more interest is the utility of these markers in management of patients presenting without clear electrocardiographic changes. Diagnosis and management of patients presenting with ST segment elevation has been clarified by large clinical trials of thrombolytic agents. In such patients, thrombolysis is the treatment of choice. Patients presenting with ST segment elevation represents the minority of patients with probable ACS 9.6% of all patients presenting to our hospital. The majority require risk stratification into high- and low-risk groups. It is here that cardiac troponins have a major role. The measurement of cTnT has been shown in a large number of studies to enable risk stratification of patients with unstable angina. The combination of cTnT, admission ECG and stress ECG can be used for a comprehensive risk stratification of patients with unstable angina. The combination of cTnT, admission ECG and stress ECG can be used for a comprehensive risk stratification which can be completed by 24 h from admission, as well as allowing a safe discharge policy from the ED. Measurements of cardiac troponins can also be used to predict prognosis in patients with other diagnostic categories. Patients with cardiac failure can be risk stratified according to cTnT status. cTnT status on admission allows subdivision into high- and low-risk groups in patients presenting with ST segment elevation. Certainly, cTnT measurement can be incorporated into a clinical decision-making strategy to assign patients to investigation and management pathways. There is evidence that cTnT may be useful to guide therapeutic options. The major issue is one of cost. In the U.K. model of managed care with undemanding diagnostic standards, the role of cTnT will be to enhance clinical decision-making strategies, to provide accurate diagnosis and to reduce lengths of stay. This can be shown to have potential for major improvements in cost efficiency. Improvements in diagnostic accuracy can reduce inappropriate long-term drug therapy. In systems with a more aggressive laboratory investigation strategy, rationalization of test numbers will provide an immediate cost reduction while improving quality. Finally, use of point-of-care testing (POCT) means that biochemical testing can be pe

  11. Two Simple and Efficient Algorithms to Compute the SP-Score Objective Function of a Multiple Sequence Alignment.

    PubMed

    Ranwez, Vincent

    2016-01-01

    Multiple sequence alignment (MSA) is a crucial step in many molecular analyses and many MSA tools have been developed. Most of them use a greedy approach to construct a first alignment that is then refined by optimizing the sum of pair score (SP-score). The SP-score estimation is thus a bottleneck for most MSA tools since it is repeatedly required and is time consuming. Given an alignment of n sequences and L sites, I introduce here optimized solutions reaching O(nL) time complexity for affine gap cost, instead of O(n2L), which are easy to implement.

  12. Alignment of chirped-pulse compressor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yakovlev, I V

    2012-11-30

    An original method of alignment of grating compressors for ultrahigh-power CPA laser systems is proposed. The use of this method for adjustment of the grating compressor of a PEARL subpetawatt laser complex made it possible to align the diffraction gratings with a second accuracy in all three angular degrees of freedom, including alignment of the grooves, and to adjust the angles of beam incidence on the grating with a high accuracy. A simple method for measuring the difference in the groove densities of gratings with accuracy better than 0.005 lines mm{sup -1} is proposed and tested. (control of laser radiationmore » parameters)« less

  13. Fast switchable ferroelectric liquid crystal gratings with two electro-optical modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Ying; Srivastava, A. K., E-mail: abhishek-srivastava-lu@yahoo.co.in; Chigrinov, V. G.

    In this article, we reveal a theoretical and experimental illustration of the Ferroelectric liquid crystal (FLC) grating fabricated by mean of patterned alignment based on photo-alignment. The complexity related to the mismatching of the predefined alignment domains on the top and bottom substrate has been avoided by incorporating only one side photo aligned substrate while the other substrate does not have any alignment layer. Depending on the easy axis in the said alignment domains and the azimuth plane of the impinging polarized light, the diffracting element can be tuned in two modes i.e. DIFF/OFF switchable and DIFF/TRANS switchable modes, whichmore » can be applied to different applications. The diffraction profile has been illustrated theoretically that fits well with the experimental finding and thus the proposed diffraction elements with fast response time and high diffraction efficiency could find application in many modern devices.« less

  14. Modular and configurable optimal sequence alignment software: Cola.

    PubMed

    Zamani, Neda; Sundström, Görel; Höppner, Marc P; Grabherr, Manfred G

    2014-01-01

    The fundamental challenge in optimally aligning homologous sequences is to define a scoring scheme that best reflects the underlying biological processes. Maximising the overall number of matches in the alignment does not always reflect the patterns by which nucleotides mutate. Efficiently implemented algorithms that can be parameterised to accommodate more complex non-linear scoring schemes are thus desirable. We present Cola, alignment software that implements different optimal alignment algorithms, also allowing for scoring contiguous matches of nucleotides in a nonlinear manner. The latter places more emphasis on short, highly conserved motifs, and less on the surrounding nucleotides, which can be more diverged. To illustrate the differences, we report results from aligning 14,100 sequences from 3' untranslated regions of human genes to 25 of their mammalian counterparts, where we found that a nonlinear scoring scheme is more consistent than a linear scheme in detecting short, conserved motifs. Cola is freely available under LPGL from https://github.com/nedaz/cola.

  15. Label-free detection of cardiac troponin-I using gold nanoparticles functionalized single-walled carbon nanotubes based chemiresistive biosensor

    NASA Astrophysics Data System (ADS)

    Rajesh, Sharma, Vikash; Puri, Nitin K.; Singh, Rajiv K.; Biradar, Ashok M.; Mulchanadani, Ashok

    2013-11-01

    We report a specific and ultrasensitive, label-free chemiresistive biosensor based on mercaptopropionic acid capped gold nanoparticles (GNP) functionalized single walled carbon nanotube (SWNT) hybrid for the detection of cardiac specific biomarker troponin-I (cTnI). GNPs were attached to SWNTs through a molecular linker 1-pyrenemethylamine. The highly specific cTnI antibody was covalently immobilized on GNPs through capping agent using carbodiimide coupling reaction. The cTnI interaction to its corresponding antibody was studied with respect to changes in conductance in SWNTs channel, and a detailed field-effect transistor characteristic was delineated. The device exhibited a linear response to cTnI from 0.01 to 10 ng ml-1.

  16. Finite Element Estimation of Protein-Ligand Association Rates with Post-Encounter Effects: Applications to Calcium binding in Troponin C and SERCA

    PubMed Central

    Kekenes-Huskey, P. M.; Gillette, A.; Hake, J.; McCammon, J. A.

    2012-01-01

    We introduce a computational pipeline and suite of software tools for the approximation of diffusion-limited binding based on a recently developed theoretical framework. Our approach handles molecular geometries generated from high-resolution structural data and can account for active sites buried within the protein or behind gating mechanisms. Using tools from the FEniCS library and the APBS solver, we implement a numerical code for our method and study two Ca2+-binding proteins: Troponin C and the Sarcoplasmic Reticulum Ca2+ ATPase (SERCA). We find that a combination of diffusional encounter and internal ‘buried channel’ descriptions provide superior descriptions of association rates, improving estimates by orders of magnitude. PMID:23293662

  17. Finite Element Estimation of Protein-Ligand Association Rates with Post-Encounter Effects: Applications to Calcium binding in Troponin C and SERCA.

    PubMed

    Kekenes-Huskey, P M; Gillette, A; Hake, J; McCammon, J A

    2012-10-31

    We introduce a computational pipeline and suite of software tools for the approximation of diffusion-limited binding based on a recently developed theoretical framework. Our approach handles molecular geometries generated from high-resolution structural data and can account for active sites buried within the protein or behind gating mechanisms. Using tools from the FEniCS library and the APBS solver, we implement a numerical code for our method and study two Ca(2+)-binding proteins: Troponin C and the Sarcoplasmic Reticulum Ca(2+) ATPase (SERCA). We find that a combination of diffusional encounter and internal 'buried channel' descriptions provide superior descriptions of association rates, improving estimates by orders of magnitude.

  18. Finite-element estimation of protein-ligand association rates with post-encounter effects: applications to calcium binding in troponin C and SERCA

    NASA Astrophysics Data System (ADS)

    Kekenes-Huskey, P. M.; Gillette, A.; Hake, J.; McCammon, J. A.

    2012-01-01

    We introduce a computational pipeline and suite of software tools for the approximation of diffusion-limited binding based on a recently developed theoretical framework. Our approach handles molecular geometries generated from high-resolution structural data and can account for active sites buried within the protein or behind gating mechanisms. Using tools from the FEniCS library and the APBS solver, we implement a numerical code for our method and study two Ca2+-binding proteins: troponin C and the sarcoplasmic reticulum Ca2+ ATPase. We find that a combination of diffusional encounter and internal ‘buried channel’ descriptions provides superior descriptions of association rates, improving estimates by orders of magnitude.

  19. PROPER: global protein interaction network alignment through percolation matching.

    PubMed

    Kazemi, Ehsan; Hassani, Hamed; Grossglauser, Matthias; Pezeshgi Modarres, Hassan

    2016-12-12

    The alignment of protein-protein interaction (PPI) networks enables us to uncover the relationships between different species, which leads to a deeper understanding of biological systems. Network alignment can be used to transfer biological knowledge between species. Although different PPI-network alignment algorithms were introduced during the last decade, developing an accurate and scalable algorithm that can find alignments with high biological and structural similarities among PPI networks is still challenging. In this paper, we introduce a new global network alignment algorithm for PPI networks called PROPER. Compared to other global network alignment methods, our algorithm shows higher accuracy and speed over real PPI datasets and synthetic networks. We show that the PROPER algorithm can detect large portions of conserved biological pathways between species. Also, using a simple parsimonious evolutionary model, we explain why PROPER performs well based on several different comparison criteria. We highlight that PROPER has high potential in further applications such as detecting biological pathways, finding protein complexes and PPI prediction. The PROPER algorithm is available at http://proper.epfl.ch .

  20. Formation of wormlike aggregates of fluorocarbon-hydrocarbon hybrid surfactant by Langmuir-Blodgett transfer and alignment of gold nanoparticles.

    PubMed

    Kondo, Yukishige; Fukuoka, Hiroshi; Nakano, Shuichi; Hayashi, Kohei; Tsukagoshi, Tatsuya; Matsumoto, Mutsuyoshi; Yoshino, Norio

    2007-05-22

    A novel anionic fluorocarbon-hydrocarbon hybrid surfactant (SS-Hyb-Na+) with a disulfide group has been synthesized from 11-bromo-1-undecanal and perfluorohexylethyl iodide via three steps. The Langmuir-Blodgett (LB) transfer of the 1:100 (mol/mol) mixed monolayer of SS-Hyb-Na+ and stearyl alcohol (C18OH) formed on an aqueous solution containing a cationic polymer, poly(diallyldimethylammonium chloride) (PDDA+Cl-) onto a hydrophobic silicon wafer yields the formation of wormlike aggregates consisting of SS-Hyb-/PDDA+ polyion complexes. It is found that the aggregates align along the withdrawal direction of the wafer substrate. When the wafer on which the wormlike aggregates exist is immersed into the dispersion of gold nanoparticles (Au NPs) prepared by the citrate reduction method, Au NPs align along the wormlike structures. Even though the surface of the wafer is placed either vertical or parallel to the monolayer compression direction during the LB transfer, the one-dimensional (1D) array of Au NPs is observed along the withdrawal direction of the wafer. This indicates that the wormlike aggregates of SS-Hyb-/PDDA+ complexes are aligned during the LB transfer, and the aligned aggregates behave as a scaffold in the 1D array of Au NPs.

  1. Orientational control of block copolymer microdomains by sub-tesla magnetic fields

    NASA Astrophysics Data System (ADS)

    Gopinadhan, Manesh; Choo, Youngwoo; Feng, Xunda; Kawabata, Kohsuke; di, Xiaojun; Osuji, Chinedum

    Magnetic fields offer a versatile approach to controlling the orientation of block copolymer (BCP) microdomains during self-assembly. To date however, such control has required the imposition of large magnetic fields (>3T), necessitating the use of complex magnet systems - either superconducting or very large conventional resistive magnets. Here we demonstrate the ability to direct BCP self-assembly using considerably smaller fields (<1T) which are accessible using simple rare-earth permanent magnets. The low field alignment is enabled by the presence of small quantities of mesogenic species that are blended into, and co-assemble with the liquid crystalline (LC) mesophase of the side-chain LC BCP under study. In situ SAXS experiments reveal a pronounced dependence of the critical alignment field strength on the stoichiometry of the blend, and the ability to generate aligned microdomains with orientational distribution coefficients exceeding 0.95 at sub-1 T fields for appropriate stoichiometries. The alignment response overall can be rationalized in terms of increased mobility and grain size due to the presence of the mesogenic additive. We use a permanent magnet to fabricate films with aligned nanopores, and the utility of this approach to generate complex BCP microdomain patterns in thin films by local field screening are highlighted. NSF DMR-1410568 and DMR-0847534.

  2. Quasiparticle Level Alignment for Photocatalytic Interfaces.

    PubMed

    Migani, Annapaoala; Mowbray, Duncan J; Zhao, Jin; Petek, Hrvoje; Rubio, Angel

    2014-05-13

    Electronic level alignment at the interface between an adsorbed molecular layer and a semiconducting substrate determines the activity and efficiency of many photocatalytic materials. Standard density functional theory (DFT)-based methods have proven unable to provide a quantitative description of this level alignment. This requires a proper treatment of the anisotropic screening, necessitating the use of quasiparticle (QP) techniques. However, the computational complexity of QP algorithms has meant a quantitative description of interfacial levels has remained elusive. We provide a systematic study of a prototypical interface, bare and methanol-covered rutile TiO2(110) surfaces, to determine the type of many-body theory required to obtain an accurate description of the level alignment. This is accomplished via a direct comparison with metastable impact electron spectroscopy (MIES), ultraviolet photoelectron spectroscopy (UPS), and two-photon photoemission (2PP) spectroscopy. We consider GGA DFT, hybrid DFT, and G0W0, scQPGW1, scQPGW0, and scQPGW QP calculations. Our results demonstrate that G0W0, or our recently introduced scQPGW1 approach, are required to obtain the correct alignment of both the highest occupied and lowest unoccupied interfacial molecular levels (HOMO/LUMO). These calculations set a new standard in the interpretation of electronic structure probe experiments of complex organic molecule/semiconductor interfaces.

  3. Protein docking by the interface structure similarity: how much structure is needed?

    PubMed

    Sinha, Rohita; Kundrotas, Petras J; Vakser, Ilya A

    2012-01-01

    The increasing availability of co-crystallized protein-protein complexes provides an opportunity to use template-based modeling for protein-protein docking. Structure alignment techniques are useful in detection of remote target-template similarities. The size of the structure involved in the alignment is important for the success in modeling. This paper describes a systematic large-scale study to find the optimal definition/size of the interfaces for the structure alignment-based docking applications. The results showed that structural areas corresponding to the cutoff values <12 Å across the interface inadequately represent structural details of the interfaces. With the increase of the cutoff beyond 12 Å, the success rate for the benchmark set of 99 protein complexes, did not increase significantly for higher accuracy models, and decreased for lower-accuracy models. The 12 Å cutoff was optimal in our interface alignment-based docking, and a likely best choice for the large-scale (e.g., on the scale of the entire genome) applications to protein interaction networks. The results provide guidelines for the docking approaches, including high-throughput applications to modeled structures.

  4. SSAW: A new sequence similarity analysis method based on the stationary discrete wavelet transform.

    PubMed

    Lin, Jie; Wei, Jing; Adjeroh, Donald; Jiang, Bing-Hua; Jiang, Yue

    2018-05-02

    Alignment-free sequence similarity analysis methods often lead to significant savings in computational time over alignment-based counterparts. A new alignment-free sequence similarity analysis method, called SSAW is proposed. SSAW stands for Sequence Similarity Analysis using the Stationary Discrete Wavelet Transform (SDWT). It extracts k-mers from a sequence, then maps each k-mer to a complex number field. Then, the series of complex numbers formed are transformed into feature vectors using the stationary discrete wavelet transform. After these steps, the original sequence is turned into a feature vector with numeric values, which can then be used for clustering and/or classification. Using two different types of applications, namely, clustering and classification, we compared SSAW against the the-state-of-the-art alignment free sequence analysis methods. SSAW demonstrates competitive or superior performance in terms of standard indicators, such as accuracy, F-score, precision, and recall. The running time was significantly better in most cases. These make SSAW a suitable method for sequence analysis, especially, given the rapidly increasing volumes of sequence data required by most modern applications.

  5. Engineering-Aligned 3D Neural Circuit in Microfluidic Device.

    PubMed

    Bang, Seokyoung; Na, Sangcheol; Jang, Jae Myung; Kim, Jinhyun; Jeon, Noo Li

    2016-01-07

    The brain is one of the most important and complex organs in the human body. Although various neural network models have been proposed for in vitro 3D neuronal networks, it has been difficult to mimic functional and structural complexity of the in vitro neural circuit. Here, a microfluidic model of a simplified 3D neural circuit is reported. First, the microfluidic device is filled with Matrigel and continuous flow is delivered across the device during gelation. The fluidic flow aligns the extracellular matrix (ECM) components along the flow direction. Following the alignment of ECM fibers, neurites of primary rat cortical neurons are grown into the Matrigel at the average speed of 250 μm d(-1) and form axon bundles approximately 1500 μm in length at 6 days in vitro (DIV). Additionally, neural networks are developed from presynaptic to postsynaptic neurons at 14 DIV. The establishment of aligned 3D neural circuits is confirmed with the immunostaining of PSD-95 and synaptophysin and the observation of calcium signal transmission. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Estimation of actomyosin active force maintained by tropomyosin and troponin complex under vertical forces in the in vitro motility assay system

    PubMed Central

    Ishii, Shuya; Kawai, Masataka; Ishiwata, Shin'ichi

    2018-01-01

    The interaction between actin filaments and myosin molecular motors is a power source of a variety of cellular functions including cell division, cell motility, and muscular contraction. In vitro motility assay examines actin filaments interacting with myosin molecules that are adhered to a substrate (e.g., glass surface). This assay has been the standard method of studying the molecular mechanisms of contraction under an optical microscope. While the force generation has been measured through an optically trapped bead to which an actin filament is attached, a force vector vertical to the glass surface has been largely ignored with the in vitro motility assay. The vertical vector is created by the gap (distance) between the trapped bead and the glass surface. In this report, we propose a method to estimate the angle between the actin filament and the glass surface by optically determining the gap size. This determination requires a motorized stage in a standard epi-fluorescence microscope equipped with optical tweezers. This facile method is applied to force measurements using both pure actin filaments, and thin filaments reconstituted from actin, tropomyosin and troponin. We find that the angle-corrected force per unit filament length in the active condition (pCa = 5.0) decreases as the angle between the filament and the glass surface increases; i.e. as the force in the vertical direction increases. At the same time, we demonstrate that the force on reconstituted thin filaments is approximately 1.5 times larger than that on pure actin filaments. The range of angles we tested was between 11° and 36° with the estimated measurement error less than 6°. These results suggest the ability of cytoplasmic tropomyosin isoforms maintaining actomyosin active force to stabilize cytoskeletal architecture. PMID:29420610

  7. A correlation between acute kidney injury and myonecrosis after scheduled percutaneous coronary intervention*

    PubMed Central

    Zhang, Min; Meng, Hao-yu; Zhao, Ying-ming; Tao, Zhi-wen; Gong, Xiao-xuan; Wang, Ze-mu; Chen, Bo; Tao, Zheng-xian; Li, Chun-jian; Zhu, Tie-bing; Wang, Lian-sheng; Yang, Zhi-jian

    2013-01-01

    Slight elevations in cardiac troponin I and T are frequently observed after percutaneous coronary intervention (PCI). Contrast-induced acute kidney injury (CI-AKI) is a complex syndrome induced by exposure to intravascular contrast media (CM). Currently, the relationships between the CM, pre-existing kidney insufficiency, CI-AKI, and myonecrosis after elective PCI are unclear. To investigate the relationship between CI-AKI and post-procedural myonecrosis (PMN) after PCI, we analyzed 327 non-ST-segment elevation acute coronary syndrome subjects undertaking elective PCI. The levels of cardiac troponins (cTns), cTnI and cTnT, at baseline and on at least one occasion 18–24 h after PCI were measured. We also recorded serum levels of creatinine (SCr) and the urine albumin:creatinine ratio (ACR) before coronary angiography, and 24–48 h and 48–72 h after contrast administration. A post-procedure increase in cTns was detected in 16.21% (53/327) of subjects with cTns levels >99th to 5×99th percentile upper reference limit (URL). Twenty-seven patients (8.26%) developed CI-AKI. CI-AKI occurred more often in subjects with PMN than in those without PMN (20.8% versus 5.8%, respectively, P=0.001). Multiple logistic regression analysis revealed that pre-existing microalbuminuria (MA) was an important independent predictor of PMN (OR: 3.31; 95% CI: 1.26–8.65, P=0.01). However, there was no correlation between the incidence of CI-AKI and PMN (OR: 2.38; 95% CI: 0.88–6.46, P=0.09). We conclude that pre-existing MA was not only an important independent predictor of CI-AKI but also of PMN. PMID:23897790

  8. Purification of cardiac myocytes from human heart biopsies for gene expression analysis.

    PubMed

    Kosloski, L M; Bales, I K; Allen, K B; Walker, B L; Borkon, A M; Stuart, R S; Pak, A F; Wacker, M J

    2009-09-01

    The collection of gene expression data from human heart biopsies is important for understanding the cellular mechanisms of arrhythmias and diseases such as cardiac hypertrophy and heart failure. Many clinical and basic research laboratories conduct gene expression analysis using RNA from whole cardiac biopsies. This allows for the analysis of global changes in gene expression in areas of the heart, while eliminating the need for more complex and technically difficult single-cell isolation procedures (such as flow cytometry, laser capture microdissection, etc.) that require expensive equipment and specialized training. The abundance of fibroblasts and other cell types in whole biopsies, however, can complicate gene expression analysis and the interpretation of results. Therefore, we have designed a technique to quickly and easily purify cardiac myocytes from whole cardiac biopsies for RNA extraction. Human heart tissue samples were collected, and our purification method was compared with the standard nonpurification method. Cell imaging using acridine orange staining of the purified sample demonstrated that >98% of total RNA was contained within identifiable cardiac myocytes. Real-time RT-PCR was performed comparing nonpurified and purified samples for the expression of troponin T (myocyte marker), vimentin (fibroblast marker), and alpha-smooth muscle actin (smooth muscle marker). Troponin T expression was significantly increased, and vimentin and alpha-smooth muscle actin were significantly decreased in the purified sample (n = 8; P < 0.05). Extracted RNA was analyzed during each step of the purification, and no significant degradation occurred. These results demonstrate that this isolation method yields a more purified cardiac myocyte RNA sample suitable for downstream applications, such as real-time RT-PCR, and allows for more accurate gene expression changes in cardiac myocytes from heart biopsies.

  9. Reverse actin sliding triggers strong myosin binding that moves tropomyosin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bekyarova, T.I.; Reedy, M.C.; Baumann, B.A.J.

    2008-09-03

    Actin/myosin interactions in vertebrate striated muscles are believed to be regulated by the 'steric blocking' mechanism whereby the binding of calcium to the troponin complex allows tropomyosin (TM) to change position on actin, acting as a molecular switch that blocks or allows myosin heads to interact with actin. Movement of TM during activation is initiated by interaction of Ca{sup 2+} with troponin, then completed by further displacement by strong binding cross-bridges. We report x-ray evidence that TM in insect flight muscle (IFM) moves in a manner consistent with the steric blocking mechanism. We find that both isometric contraction, at highmore » [Ca{sup 2+}], and stretch activation, at lower [Ca{sup 2+}], develop similarly high x-ray intensities on the IFM fourth actin layer line because of TM movement, coinciding with x-ray signals of strong-binding cross-bridge attachment to helically favored 'actin target zones.' Vanadate (Vi), a phosphate analog that inhibits active cross-bridge cycling, abolishes all active force in IFM, allowing high [Ca{sup 2+}] to elicit initial TM movement without cross-bridge attachment or other changes from relaxed structure. However, when stretched in high [Ca{sup 2+}], Vi-'paralyzed' fibers produce force substantially above passive response at pCa {approx} 9, concurrent with full conversion from resting to active x-ray pattern, including x-ray signals of cross-bridge strong-binding and TM movement. This argues that myosin heads can be recruited as strong-binding 'brakes' by backward-sliding, calcium-activated thin filaments, and are as effective in moving TM as actively force-producing cross-bridges. Such recruitment of myosin as brakes may be the major mechanism resisting extension during lengthening contractions.« less

  10. Cardiac troponin I is modified in the myocardium of bypass patients.

    PubMed

    McDonough, J L; Labugger, R; Pickett, W; Tse, M Y; MacKenzie, S; Pang, S C; Atar, D; Ropchan, G; Van Eyk, J E

    2001-01-02

    Selective proteolysis of cardiac troponin I (cTnI) is a proposed mechanism of contractile dysfunction in stunned myocardium, and the presence of cTnI degradation products in serum may reflect the functional state of the remaining viable myocardium. However, recent swine and canine studies have not demonstrated stunning-dependent cTnI degradation. To address the universality of cTnI modification, myocardial biopsy samples were obtained from coronary artery bypass patients (n=37) before and 10 minutes after removal of cross-clamp. Analysis of biopsy samples for cTnI by Western blotting revealed a spectrum of modified cTnI products in myocardium both before and after cross-clamp, including degradation products (7 products resulting from differential N- and C-terminal processing) and covalent complexes (3 products). In particular, a 22-kDa cTnI degradation product with C-terminal proteolysis was identified, which may represent an initial ischemia-dependent cTnI modification, similar to cTnI(1-193) observed in stunned rat myocardium. Although no systematic change in amount of modified cTnI was observed, subgroups of patients displayed an increase (n=10, 85+/-5% of cTnI remaining intact before cross-clamp versus 75+/-5% after) or a decrease (n=12, 67+/-5% before versus 78+/-5% after). Electron microscopy demonstrated normal ultrastructure in biopsy samples, which suggests no necrosis was present. In addition, cTnI modification products were observed in serum through a modified SDS-PAGE methodology. cTnI modification, in particular proteolysis, occurs in myocardium of bypass patients and may play a key role in stunning in some bypass patients.

  11. YAHA: fast and flexible long-read alignment with optimal breakpoint detection.

    PubMed

    Faust, Gregory G; Hall, Ira M

    2012-10-01

    With improved short-read assembly algorithms and the recent development of long-read sequencers, split mapping will soon be the preferred method for structural variant (SV) detection. Yet, current alignment tools are not well suited for this. We present YAHA, a fast and flexible hash-based aligner. YAHA is as fast and accurate as BWA-SW at finding the single best alignment per query and is dramatically faster and more sensitive than both SSAHA2 and MegaBLAST at finding all possible alignments. Unlike other aligners that report all, or one, alignment per query, or that use simple heuristics to select alignments, YAHA uses a directed acyclic graph to find the optimal set of alignments that cover a query using a biologically relevant breakpoint penalty. YAHA can also report multiple mappings per defined segment of the query. We show that YAHA detects more breakpoints in less time than BWA-SW across all SV classes, and especially excels at complex SVs comprising multiple breakpoints. YAHA is currently supported on 64-bit Linux systems. Binaries and sample data are freely available for download from http://faculty.virginia.edu/irahall/YAHA. imh4y@virginia.edu.

  12. Validating Automated Measures of Text Complexity

    ERIC Educational Resources Information Center

    Sheehan, Kathleen M.

    2017-01-01

    Automated text complexity measurement tools (also called readability metrics) have been proposed as a way to help teachers, textbook publishers, and assessment developers select texts that are closely aligned with the new, more demanding text complexity expectations specified in the Common Core State Standards. This article examines a critical…

  13. Effect of alignment perturbations in a trans-tibial prosthesis user: A pilot study.

    PubMed

    Courtney, Anna; Orendurff, Michael S; Buis, Arjan

    2016-04-01

    A recurring complication in trans-tibial prosthetic limb users is "poor socket fit" with painful residuum-socket interfaces, a consequence of excess pressure. This is due to both poor socket fit and poor socket alignment; however, the interaction of these factors has not been quantified. Through evaluation of kinetic data this study aimed to articulate an interaction uniting socket design, alignment and interface pressures. The results will help to refine future studies and will hopefully help determine whether sockets can be designed, fitted and aligned to maximize mobility whilst minimizing injurious forces. Interface pressures were recorded throughout ambulation in one user with "optimal (reference) alignment" followed by 5 malalignments in a patellar tendon-bearing and a hydrocast socket. Marked differences in pressure distribution were discovered when equating the patellar tendon-bearing against the hydrocast socket and when comparing interface pressures from reference with offset alignment. Patellar tendon-bearing sockets were found to be more sensitive to alignment perturbations than hydrocast sockets. A complex interaction was found, with the most prominent finding demonstrating the requisite for attainment of optimal alignment: a translational alignment error of 10 mm can increase maximum peak pressures by 227% (mean 17.5%). Refinements for future trials are described and the necessity for future research into socket design, alignment and interface pressures has been estabilished.

  14. Engineering survey planning for the alignment of a particle accelerator: part I. Proposition of an assessment method

    NASA Astrophysics Data System (ADS)

    Junqueira Leão, Rodrigo; Raffaelo Baldo, Crhistian; Collucci da Costa Reis, Maria Luisa; Alves Trabanco, Jorge Luiz

    2018-03-01

    The performance of particle accelerators depends highly on the relative alignment between their components. The position and orientation of the magnetic lenses that form the trajectory of the charged beam is kept to micrometric tolerances in a range of hundreds of meters of the length of the machines. Therefore, the alignment problem is fundamentally of a dimensional metrology nature. There is no common way of expressing these tolerances in terms of terminology and alignment concept. The alignment needs for a certain machine is normally given in terms of deviations between the position of any magnet in the accelerator and the fitted line that relates the actual position of the magnets’ assembly. Root mean square errors and standard deviations are normally used interchangeably and measurement uncertainty is often neglected. Although some solutions have been employed successfully in several accelerators, there is no off-the-shelf solution to perform the alignment. Also, each alignment campaign makes use of different measuring instruments to achieve the desired results, which makes the alignment process a complex measurement chain. This paper explores these issues by reviewing the tolerances specified for the alignment of particle accelerators, and proposes a metric to assess the quality of the alignment. The metric has the advantage of fully integrating the measurement uncertainty in the process.

  15. Molecular engineering of lanthanide ion chelating phospholipids generating assemblies with a switched magnetic susceptibility.

    PubMed

    Isabettini, Stéphane; Massabni, Sarah; Hodzic, Arnel; Durovic, Dzana; Kohlbrecher, Joachim; Ishikawa, Takashi; Fischer, Peter; Windhab, Erich J; Walde, Peter; Kuster, Simon

    2017-08-09

    Lanthanide ion (Ln 3+ ) chelating amphiphiles are powerful molecules for tailoring the magnetic response of polymolecular assemblies. Mixtures of 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and 1,2-dimyristoyl-sn-glycero-3-phospho-ethanolamine-diethylene triaminepentaacetate (DMPE-DTPA) complexed to Ln 3+ deliver highly magnetically responsive bicelles. Their magnetic properties are readily tuned by changing the bicellar size or the magnetic susceptibility Δχ of the bilayer lipids. The former technique is intrinsically bound to the region of the phase diagram guarantying the formation of bicelles. Methods aiming towards manipulating the Δχ of the bilayer are comparatively more robust, flexible and lacking. Herein, we synthesized a new Ln 3+ chelating phospholipid using glutamic acid as a backbone: DMPE-Glu-DTPA. The chelate polyhedron was specifically engineered to alter the Δχ, whilst remaining geometrically similar to DMPE-DTPA. Planar asymmetric assemblies hundreds of nanometers in size were achieved presenting unprecedented magnetic alignments. The DMPE-Glu-DTPA/Ln 3+ complex switched the Δχ, achieving perpendicular alignment of assemblies containing Dy 3+ and parallel alignment of those containing Tm 3+ . Moreover, samples with chelated Yb 3+ were more alignable than the Tm 3+ chelating counterparts. Such a possibility has never been demonstrated for planar Ln 3+ chelating polymolecular assemblies. The physico-chemical properties of these novel assemblies were further studied by monitoring the alignment behavior at different temperatures and by including 16 mol% of cholesterol (Chol-OH) in the phospholipid bilayer. The DMPE-Glu-DTPA/Ln 3+ complex and the resulting assemblies are promising candidates for applications in numerous fields including pharmaceutical technologies, structural characterization of membrane biomolecules by NMR spectroscopy, as contrasting agents for magnetic resonance imaging, and for the development of smart optical gels.

  16. Simultaneous phylogeny reconstruction and multiple sequence alignment

    PubMed Central

    Yue, Feng; Shi, Jian; Tang, Jijun

    2009-01-01

    Background A phylogeny is the evolutionary history of a group of organisms. To date, sequence data is still the most used data type for phylogenetic reconstruction. Before any sequences can be used for phylogeny reconstruction, they must be aligned, and the quality of the multiple sequence alignment has been shown to affect the quality of the inferred phylogeny. At the same time, all the current multiple sequence alignment programs use a guide tree to produce the alignment and experiments showed that good guide trees can significantly improve the multiple alignment quality. Results We devise a new algorithm to simultaneously align multiple sequences and search for the phylogenetic tree that leads to the best alignment. We also implemented the algorithm as a C program package, which can handle both DNA and protein data and can take simple cost model as well as complex substitution matrices, such as PAM250 or BLOSUM62. The performance of the new method are compared with those from other popular multiple sequence alignment tools, including the widely used programs such as ClustalW and T-Coffee. Experimental results suggest that this method has good performance in terms of both phylogeny accuracy and alignment quality. Conclusion We present an algorithm to align multiple sequences and reconstruct the phylogenies that minimize the alignment score, which is based on an efficient algorithm to solve the median problems for three sequences. Our extensive experiments suggest that this method is very promising and can produce high quality phylogenies and alignments. PMID:19208110

  17. Evaluation of Cardiac Toxicity Biomarkers in Rats from Different Laboratories

    PubMed Central

    Kim, Kyuri; Chini, Naseem; Fairchild, David G.; Engle, Steven K.; Reagan, William J.; Summers, Sandra D.; Mirsalis, Jon C.

    2016-01-01

    There is a great need for improved diagnostic and prognostic accuracy of potential cardiac toxicity in drug development. This study reports the evaluation of several commercially available biomarker kits by three institutions (SRI, Eli Lilly and Pfizer) for the discrimination between myocardial degeneration/necrosis and cardiac hypertrophy as well as the assessment of the inter-laboratory and inter-platform variation in results. Serum concentrations of natriuretic peptides (NT-proANP, NT-proBNP), cardiac and skeletal troponins (cTnI, cTnT, sTnI), myosin light chain 3 (Myl3) and fatty acid binding protein 3 (FABP3) were assessed in rats treated with minoxidil and isoproterenol. Minoxidil caused increased heart-to-body weight ratios and prominent elevations in NT-proANP and NT-proBNP concentrations detected at 24 hr postdose without elevation in troponins, Myl3 or FABP3 and with no abnormal histopathological findings. Isoproterenol caused ventricular leukocyte infiltration, myocyte fibrosis and necrosis with increased concentrations of the natriuretic peptides, cardiac troponins and Myl3. These results reinforce the advantages of a multi-marker strategy in elucidating the underlying cause of cardiac insult and detecting myocardial tissue damage at 24 hr post-treatment. The inter-laboratory and inter-platform comparison analyses also showed that the data obtained from different laboratories and platforms are highly correlated and reproducible, making these biomarkers widely applicable in preclinical studies. PMID:27638646

  18. Ultrasensitive and low-volume point-of-care diagnostics on flexible strips - a study with cardiac troponin biomarkers

    NASA Astrophysics Data System (ADS)

    Shanmugam, Nandhinee Radha; Muthukumar, Sriram; Prasad, Shalini

    2016-09-01

    We demonstrate a flexible, mechanically stable, and disposable electrochemical sensor platform for monitoring cardiac troponins through the detection and quantification of cardiac Troponin-T (cTnT). We designed and fabricated nanostructured zinc oxide (ZnO) sensing electrodes on flexible porous polyimide substrates. We demonstrate ultrasensitive detection is capable at very low sample volumes due to the confinement phenomenon of target species within the ZnO nanostructures leading to enhancement of biomolecular binding on the sensor electrode surface. The performance of the ZnO nanostructured sensor electrode was evaluated against gold and nanotextured ZnO electrodes. The electrochemical sensor functions on affinity based immunoassay principles whereby monoclonal antibodies for cTnT were immobilized on the sensor electrodes using thiol based chemistry. Detection of cTnT in phosphate buffered saline (PBS) and human serum (HS) buffers was achieved at low sample volumes of 20 μL using non-faradaic electrochemical impedance spectroscopy (EIS). Limit of detection (LOD) of 1E-4 ng/mL (i.e. 1 pg/mL) at 7% CV (coefficient of variation) for cTnT in HS was demonstrated on nanostructured ZnO electrodes. The mechanical integrity of the flexible biosensor platform was demonstrated with cyclic bending tests. The sensor performed within 12% CV after 100 bending cycles demonstrating the robustness of the nanostructured ZnO electrochemical sensor platform.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlecht, William; Li, King-Lun; Hu, Dehong

    By examining the behavior of each Ca2+ -sensitizer on cTnC at different levels of reconstitution (cTnI-cTnC, full troponin, or full troponin in thin filament) the importance of these proteins on sensitizer efficacy was evaluated, lending insight into the mechanism of action behind each drug. A fluorescence based approach was used to monitor the opening and closing of cardiac troponin C's hydrophobic pocket in the presence and absence of four common Ca2+ -sensitizers: EMD 57033, levosimendan, bepridil and pimobendan. Ca2+ -titration experiments were employed to determine the effect on Ca2+- sensitivity and cooperativity of cTnC opening, while stopped flow experiments weremore » used to investigate the impact on cTnC relaxation kinetics. This study shows EMD 57033 is unable to sensitize cTnC to Ca2+, and likely requires the presence of myosin to illicit a response. Levosimendan, bepridil, and pimobendan were all able to increase the sensitivity of cTnC for Ca2+ to varying degrees; levosimendan and pimobendan reduced the rate of cTnC closing, while bepridil increased this rate. Additionally the same experiments were run on thin filament samples containing cTnT (T204E), a known Ca2+- blunting phosphorylation mimic. Levosimendan, bepridil, and pimobendan were found to elevate the Ca2+-sensitivity of cTnT(T204E) containing thin filaments to within range of the wild type thin filaments.« less

  20. Evaluation of plasma sphingosine 1-phosphate, hepcidin and cardiovascular damage biomarkers (cardiac troponin I and homocysteine) in rats infected with brucellosis and vaccinated (Rev-1, RB-51).

    PubMed

    Azimzadeh, Kaveh; Nasrollahi Nargesabad, Reza; Vousooghi, Nasim

    2017-08-01

    Brucellosis is known as one of important zoonosis. Studying the histological and biochemical effects of the disease could help to increase our knowledge about it. The aim of the present study was to evaluate changes of plasma parameters after intraperitoneal injection of two species of Brucella (Brucella melitensis and Brucella abortus) and two vaccines (Rev-1, RB-51) in the rat. Forty male rats were divided into five groups (n = 8 in each group). Two groups received suspensions of Brucella abortus and Brucella melitensis and two other groups were injected intraperitoneally with two mentioned vaccines and the last group received only distilled water. The results showed a significant increase in sphingosine 1-phosphate, Malondialdehyde, hepcidin, homocysteine, cardiac troponin I and copper levels and a considerable decrease in the levels of iron and zinc (P ≤ 0.01) in infected groups compared to the control animals. In vaccinated groups, hepcidin was increased but other parameters were not changed in comparison to the control group. It can be concluded that increase of homocysteine and cardiac troponin I in brucellosis could be a warning for cardiac adverse effects. Besides, increase of sphingosine 1-phosphate probably indicates its stimulant and modulatory effects in anti- Brucellosis biochemical pathways of the host. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Nerve-responsive troponin I slow promoter does not respond to unloading

    NASA Technical Reports Server (NTRS)

    Criswell, D. S.; Hodgson, V. R.; Hardeman, E. C.; Booth, F. W.

    1998-01-01

    We examined the regulation of the troponin I slow (TnIs) promoter during skeletal muscle unloading-induced protein isoform transition, by using a transgenic mouse line harboring the -4,200 to +12 base pairs region of the human TnIs promoter. Eighteen female transgenic mice ( approximately 30 g body mass) were randomly divided into two groups: weight-bearing (WB) controls (n = 9) and hindlimb unloaded (HU; n = 9). The HU mice were tail suspended for 7 days. Body mass was unchanged in the WB group but was reduced (-6%; P < 0.05) after the HU treatment. Absolute soleus muscle mass (-25%) and soleus mass relative to body mass (-16%) were both lower (P < 0.05) in the HU group compared with the WB mice. Northern blot analyses indicate that 7 days of HU result in a 64% decrease (P < 0.05) in the abundance of endogenous TnIs mRNA (microg/mg muscle) in the mouse soleus. Furthermore, there is a trend for the abundance of the fast troponin I mRNA to be increased (+34%). Analysis of transgenic chloramphenicol acetyltransferase activity in the soleus muscle revealed no difference (P > 0.05) between WB and HU groups. We conclude that additional elements are necessary for the TnIs gene to respond to an unloading-induced, slow-to-fast isoform transition stimulus.

  2. Prevalence of myocarditis in pediatric intensive care unit cases presenting with other system involvement.

    PubMed

    Rady, Hanaa Ibrahim; Zekri, Hanan

    2015-01-01

    To assess children with myocarditis, the frequency of various presenting symptoms, and the accuracy of different investigations in the diagnosis. This was an observational study of 63 patients admitted to PICU with non-cardiac diagnosis. Cardiac enzymes, chest-X ray, echocardiography, and electrocardiogram were performed to diagnose myocarditis among those patients. There were 16 cases of definite myocarditis. The age distribution was non-normal, with median of 5.5 months (3.25-21). Of the 16 patients who were diagnosed with myocarditis, 62.5% were originally diagnosed as having respiratory problems, and there were more females than males. Among the present cases, the accuracy of cardiac enzymes (cardiac troponin T [cTn] and creatine phosphokinase MB [CKMB]) in the diagnosis of myocarditis was only 63.5%, while the accuracy of low fractional shortening and of chest-X ray cardiomegaly was 85.7 and 80.9%; respectively. Cardiac troponin folds 2.02 had positive predictive value of 100%, negative predictive value of 88.7%, specificity of 100%, sensitivity of 62.5%, and accuracy of 90.5%. Children with myocarditis present with symptoms that can be mistaken for other types of illnesses. When clinical suspicion of myocarditis exists, chest-X ray and echocardiography are sufficient as screening tests. Cardiac troponins confirm the diagnosis in screened cases, with specificity of 100%. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  3. Both cell fusion and transdifferentiation account for the transformation of human peripheral blood CD34-positive cells into cardiomyocytes in vivo.

    PubMed

    Zhang, Sui; Wang, Dachun; Estrov, Zeev; Raj, Sean; Willerson, James T; Yeh, Edward T H

    2004-12-21

    Adult human peripheral blood CD34-positive (CD34+) cells appear to transform into cardiomyocytes in the injured hearts of severe combined immunodeficient mice. It remains unclear, however, whether the apparent transformation is the result of transdifferentiation of the donor stem cells or of fusion of the donor cell with the cardiomyocyte of the recipients. We performed flow cytometry analyses of cells isolated from the hearts of mice that received human CD34+ cells. Human HLA-ABC antigen and cardiac troponin T or Nkx2.5 were used as markers for cardiomyocytes derived from human CD34+ cells, and HLA-ABC and VE-cadherin were used to identify the transformed endothelial cells. The double-positive cells were collected and interphase fluorescence in situ hybridization was used to detect the expression of human and mouse X chromosomes in these cells. We found that 73.3% of nuclei derived from HLA+ and troponin T+ or Nkx2.5+ cardiomyocytes contain both human and mouse X chromosomes and 23.7% contain only human X chromosome. In contrast, the nuclei of HLA-, troponin T+ cells contain only mouse X chromosomes. Furthermore, 97.3% of endothelial cells derived from CD34+ cells contained human X chromosome only. Thus, both cell fusion and transdifferentiation may account for the transformation of peripheral blood CD34+ cells into cardiomyocytes in vivo.

  4. Biomarker evaluation of skeletal muscle toxicity following clofibrate administration in rats.

    PubMed

    Bodié, Karen; Buck, Wayne R; Pieh, Julia; Liguori, Michael J; Popp, Andreas

    2016-05-01

    The use of sensitive biomarkers to monitor skeletal muscle toxicity in preclinical toxicity studies is important for the risk assessment in humans during the development of a novel compound. Skeletal muscle toxicity in Sprague Dawley Rats was induced with clofibrate at different dose levels for 7 days to compare standard clinical pathology assays with novel skeletal muscle and cardiac muscle biomarkers, gene expression and histopathological changes. The standard clinical pathology assays aspartate aminotransferase (AST), alanine aminotransferase (ALT), and creatine kinase (CK) enzyme activity were compared to novel biomarkers fatty acid binding protein 3 (Fabp3), myosin light chain 3 (Myl3), muscular isoform of CK immunoreactivity (three isoforms CKBB, CKMM, CKMB), parvalbumin (Prv), skeletal troponin I (sTnI), cardiac troponin T (cTnT), cardiac troponin I (cTnI), CKMM, and myoglobin (Myo). The biomarker elevations were correlated to histopathological findings detected in several muscles and gene expression changes. Clofibrate predominantly induced skeletal muscle toxicity of type I fibers of low magnitude. Useful biomarkers for skeletal muscle toxicity were AST, Fabp3, Myl3, (CKMB) and sTnI. Measurements of CK enzyme activity by a standard clinical assay were not useful for monitoring clofibrate-induced skeletal muscle toxicity in the rat at the doses used in this study. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.

  5. Multistage Complexity in Language Proficiency Assessment: A Framework for Aligning Theoretical Perspectives, Test Development, and Psychometrics

    ERIC Educational Resources Information Center

    Luecht, Richard M.

    2003-01-01

    This article contends that the necessary links between constructs and test scores/decisions in language assessment must be established through principled design procedures that align three models: (1) a theoretical construct model; (2) a test development model; and (3) a psychometric scoring model. The theoretical construct model articulates the…

  6. Changes in the Cognitive Complexity of English Instruction: The Moderating Effects of School and Classroom Characteristics

    ERIC Educational Resources Information Center

    Polikoff, Morgan S.; Struthers, Kathryn

    2013-01-01

    Background/Context: A central aim of standards-based reform is to close achievement gaps by raising academic standards for all students. Rigorous standards coupled with aligned assessments will purportedly improve student opportunity to learn through high-quality, aligned instruction. After 10 years of No Child Left Behind (NCLB), the impact of…

  7. Polarization properties of below-threshold harmonics from aligned molecules H2+ in linearly polarized laser fields.

    PubMed

    Dong, Fulong; Tian, Yiqun; Yu, Shujuan; Wang, Shang; Yang, Shiping; Chen, Yanjun

    2015-07-13

    We investigate the polarization properties of below-threshold harmonics from aligned molecules in linearly polarized laser fields numerically and analytically. We focus on lower-order harmonics (LOHs). Our simulations show that the ellipticity of below-threshold LOHs depends strongly on the orientation angle and differs significantly for different harmonic orders. Our analysis reveals that this LOH ellipticity is closely associated with resonance effects and the axis symmetry of the molecule. These results shed light on the complex generation mechanism of below-threshold harmonics from aligned molecules.

  8. The deterministic optical alignment of the HERMES spectrograph

    NASA Astrophysics Data System (ADS)

    Gers, Luke; Staszak, Nicholas

    2014-07-01

    The High Efficiency and Resolution Multi Element Spectrograph (HERMES) is a four channel, VPH-grating spectrograph fed by two 400 fiber slit assemblies whose construction and commissioning has now been completed at the Anglo Australian Telescope (AAT). The size, weight, complexity, and scheduling constraints of the system necessitated that a fully integrated, deterministic, opto-mechanical alignment system be designed into the spectrograph before it was manufactured. This paper presents the principles about which the system was assembled and aligned, including the equipment and the metrology methods employed to complete the spectrograph integration.

  9. Automatic laser beam alignment using blob detection for an environment monitoring spectroscopy

    NASA Astrophysics Data System (ADS)

    Khidir, Jarjees; Chen, Youhua; Anderson, Gary

    2013-05-01

    This paper describes a fully automated system to align an infra-red laser beam with a small retro-reflector over a wide range of distances. The component development and test were especially used for an open-path spectrometer gas detection system. Using blob detection under OpenCV library, an automatic alignment algorithm was designed to achieve fast and accurate target detection in a complex background environment. Test results are presented to show that the proposed algorithm has been successfully applied to various target distances and environment conditions.

  10. Shear induced alignment of short nanofibers in 3D printed polymer composites.

    PubMed

    Yunus, Doruk Erdem; Shi, Wentao; Sohrabi, Salman; Liu, Yaling

    2016-12-09

    3D printing of composite materials offers an opportunity to combine the desired properties of composite materials with the flexibility of additive manufacturing in geometric shape and complexity. In this paper, the shear-induced alignment of aluminum oxide nanowires during stereolithography printing was utilized to fabricate a nanowire reinforced polymer composite. To align the fibers, a lateral oscillation mechanism was implemented and combined with wall pattern printing technique to generate shear flow in both vertical and horizontal directions. A series of specimens were fabricated for testing the composite material's tensile strength. The results showed that mechanical properties of the composite were improved by reinforcement of nanofibers through shear induced alignment. The improvement of tensile strength was approximately ∼28% by aligning the nanowires at 5 wt% (∼1.5% volume fraction) loading of aluminum oxide nanowires.

  11. AlexSys: a knowledge-based expert system for multiple sequence alignment construction and analysis

    PubMed Central

    Aniba, Mohamed Radhouene; Poch, Olivier; Marchler-Bauer, Aron; Thompson, Julie Dawn

    2010-01-01

    Multiple sequence alignment (MSA) is a cornerstone of modern molecular biology and represents a unique means of investigating the patterns of conservation and diversity in complex biological systems. Many different algorithms have been developed to construct MSAs, but previous studies have shown that no single aligner consistently outperforms the rest. This has led to the development of a number of ‘meta-methods’ that systematically run several aligners and merge the output into one single solution. Although these methods generally produce more accurate alignments, they are inefficient because all the aligners need to be run first and the choice of the best solution is made a posteriori. Here, we describe the development of a new expert system, AlexSys, for the multiple alignment of protein sequences. AlexSys incorporates an intelligent inference engine to automatically select an appropriate aligner a priori, depending only on the nature of the input sequences. The inference engine was trained on a large set of reference multiple alignments, using a novel machine learning approach. Applying AlexSys to a test set of 178 alignments, we show that the expert system represents a good compromise between alignment quality and running time, making it suitable for high throughput projects. AlexSys is freely available from http://alnitak.u-strasbg.fr/∼aniba/alexsys. PMID:20530533

  12. Troponin test

    MedlinePlus

    ... Bates ER, Blankenship JC, et al. 2015 ACC/AHA/SCAI Focused update on primary percutaneous coronary intervention ... myocardial infarction: an update of the 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention and the ...

  13. Effects of the whole-body cryotherapy on NTproBNP, hsCRP and troponin I in athletes.

    PubMed

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; d'Eril, Gianlodovico Melzi

    2009-11-01

    Whole-body cryotherapy refers to brief exposure to very cold air for treating symptoms of various illnesses. In sports medicine, whole-body cryotherapy is administered to improve recovery from muscular trauma. As specific studies are lacking, we measured cardiac markers in 10 top-level rugby players of the Italian National team before and after a 1-week course of daily sessions of whole-body cryotherapy. All subjects continued with the same training workload as that of the previous weeks. N-terminal pro B-type natriuretic peptide (NTproBNP) levels increased but remained within the normal range, whilst troponin I (TnI) and high sensitivity C-reactive protein (hsCRP) were unchanged. Whole-body cryotherapy did not impair cardiac function in this sample of elite athletes.

  14. Selection of specific inhibitor peptides in enzyme-linked immunosorbent assay (ELISA) of cardiac troponin I using immuno-dominant epitopes as competitor.

    PubMed

    Rezaee, Majid Asiabanha; Rasaee, Mohammad Javad; Mohammadnejad, Javad

    2017-01-01

    Human cardiac troponin I (cTni) is the gold marker for early diagnosis of myocardial infarction. In this regard, four immune-dominant epitopes of cTni were predicted and their 3D structures were determined. Thereafter, the competitive performance of the peptides was monitored with the developed polyclonal antibody-based indirect competitive ELISA; a half-maximal inhibitory concentration (IC50) of 0.49 (µg/mL) and detection limit of 0.037 (µg/mL) were achieved for recombinant cTni. The competitive ELISA determined sensitivity levels of 0.306, 0.141, 0.960, and 0.155 (µg/mL), respectively, for each peptide as competitor. We indicated that two of the selected epitopes have significant sensitivity scales and inhibition ability.

  15. Complexity matching in dyadic conversation.

    PubMed

    Abney, Drew H; Paxton, Alexandra; Dale, Rick; Kello, Christopher T

    2014-12-01

    Recent studies of dyadic interaction have examined phenomena of synchronization, entrainment, alignment, and convergence. All these forms of behavioral matching have been hypothesized to play a supportive role in establishing coordination and common ground between interlocutors. In the present study, evidence is found for a new kind of coordination termed complexity matching. Temporal dynamics in conversational speech signals were analyzed through time series of acoustic onset events. Timing in periods of acoustic energy was found to exhibit behavioral matching that reflects complementary timing in turn-taking. In addition, acoustic onset times were found to exhibit power law clustering across a range of timescales, and these power law functions were found to exhibit complexity matching that is distinct from behavioral matching. Complexity matching is discussed in terms of interactive alignment and other theoretical principles that lead to new hypotheses about information exchange in dyadic conversation and interaction in general. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  16. Chemometric Analysis of Gas Chromatography – Mass Spectrometry Data using Fast Retention Time Alignment via a Total Ion Current Shift Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nadeau, Jeremy S.; Wright, Bob W.; Synovec, Robert E.

    2010-04-15

    A critical comparison of methods for correcting severely retention time shifted gas chromatography-mass spectrometry (GC-MS) data is presented. The method reported herein is an adaptation to the Piecewise Alignment Algorithm to quickly align severely shifted one-dimensional (1D) total ion current (TIC) data, then applying these shifts to broadly align all mass channels throughout the separation, referred to as a TIC shift function (SF). The maximum shift varied from (-) 5 s in the beginning of the chromatographic separation to (+) 20 s toward the end of the separation, equivalent to a maximum shift of over 5 peak widths. Implementing themore » TIC shift function (TIC SF) prior to Fisher Ratio (F-Ratio) feature selection and then principal component analysis (PCA) was found to be a viable approach to classify complex chromatograms, that in this study were obtained from GC-MS separations of three gasoline samples serving as complex test mixtures, referred to as types C, M and S. The reported alignment algorithm via the TIC SF approach corrects for large dynamic shifting in the data as well as subtle peak-to-peak shifts. The benefits of the overall TIC SF alignment and feature selection approach were quantified using the degree-of-class separation (DCS) metric of the PCA scores plots using the type C and M samples, since they were the most similar, and thus the most challenging samples to properly classify. The DCS values showed an increase from an initial value of essentially zero for the unaligned GC-TIC data to a value of 7.9 following alignment; however, the DCS was unchanged by feature selection using F-Ratios for the GC-TIC data. The full mass spectral data provided an increase to a final DCS of 13.7 after alignment and two-dimensional (2D) F-Ratio feature selection.« less

  17. Multivariate curve resolution based chromatographic peak alignment combined with parallel factor analysis to exploit second-order advantage in complex chromatographic measurements.

    PubMed

    Parastar, Hadi; Akvan, Nadia

    2014-03-13

    In the present contribution, a new combination of multivariate curve resolution-correlation optimized warping (MCR-COW) with trilinear parallel factor analysis (PARAFAC) is developed to exploit second-order advantage in complex chromatographic measurements. In MCR-COW, the complexity of the chromatographic data is reduced by arranging the data in a column-wise augmented matrix, analyzing using MCR bilinear model and aligning the resolved elution profiles using COW in a component-wise manner. The aligned chromatographic data is then decomposed using trilinear model of PARAFAC in order to exploit pure chromatographic and spectroscopic information. The performance of this strategy is evaluated using simulated and real high-performance liquid chromatography-diode array detection (HPLC-DAD) datasets. The obtained results showed that the MCR-COW can efficiently correct elution time shifts of target compounds that are completely overlapped by coeluted interferences in complex chromatographic data. In addition, the PARAFAC analysis of aligned chromatographic data has the advantage of unique decomposition of overlapped chromatographic peaks to identify and quantify the target compounds in the presence of interferences. Finally, to confirm the reliability of the proposed strategy, the performance of the MCR-COW-PARAFAC is compared with the frequently used methods of PARAFAC, COW-PARAFAC, multivariate curve resolution-alternating least squares (MCR-ALS), and MCR-COW-MCR. In general, in most of the cases the MCR-COW-PARAFAC showed an improvement in terms of lack of fit (LOF), relative error (RE) and spectral correlation coefficients in comparison to the PARAFAC, COW-PARAFAC, MCR-ALS and MCR-COW-MCR results. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Genome alignment with graph data structures: a comparison

    PubMed Central

    2014-01-01

    Background Recent advances in rapid, low-cost sequencing have opened up the opportunity to study complete genome sequences. The computational approach of multiple genome alignment allows investigation of evolutionarily related genomes in an integrated fashion, providing a basis for downstream analyses such as rearrangement studies and phylogenetic inference. Graphs have proven to be a powerful tool for coping with the complexity of genome-scale sequence alignments. The potential of graphs to intuitively represent all aspects of genome alignments led to the development of graph-based approaches for genome alignment. These approaches construct a graph from a set of local alignments, and derive a genome alignment through identification and removal of graph substructures that indicate errors in the alignment. Results We compare the structures of commonly used graphs in terms of their abilities to represent alignment information. We describe how the graphs can be transformed into each other, and identify and classify graph substructures common to one or more graphs. Based on previous approaches, we compile a list of modifications that remove these substructures. Conclusion We show that crucial pieces of alignment information, associated with inversions and duplications, are not visible in the structure of all graphs. If we neglect vertex or edge labels, the graphs differ in their information content. Still, many ideas are shared among all graph-based approaches. Based on these findings, we outline a conceptual framework for graph-based genome alignment that can assist in the development of future genome alignment tools. PMID:24712884

  19. Computational complexity of algorithms for sequence comparison, short-read assembly and genome alignment.

    PubMed

    Baichoo, Shakuntala; Ouzounis, Christos A

    A multitude of algorithms for sequence comparison, short-read assembly and whole-genome alignment have been developed in the general context of molecular biology, to support technology development for high-throughput sequencing, numerous applications in genome biology and fundamental research on comparative genomics. The computational complexity of these algorithms has been previously reported in original research papers, yet this often neglected property has not been reviewed previously in a systematic manner and for a wider audience. We provide a review of space and time complexity of key sequence analysis algorithms and highlight their properties in a comprehensive manner, in order to identify potential opportunities for further research in algorithm or data structure optimization. The complexity aspect is poised to become pivotal as we will be facing challenges related to the continuous increase of genomic data on unprecedented scales and complexity in the foreseeable future, when robust biological simulation at the cell level and above becomes a reality. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Sensitive Troponin I and Stress Testing in the Emergency Department for the Early Management of Chest Pain Using 2-Hour Protocol.

    PubMed

    Dadkhah, Shahriar; Almuwaqqat, Zakaria; Sulaiman, Samian; Husein, Husein; Nguyen, Quang; Ali, Saad; Taskesen, Tuncay

    2017-09-01

    Despite improvements in identifying high-risk patients with non-ST segment ACS (acute coronary syndrome), low risk patients presenting with atypical chest pain and non-diagnostic Electrocardiogram (ECG) continued to undergo unnecessary admissions and testing. Since 1992, our chest pain protocol included using 4-hour serial biomarkers from ED admission in combination with stress testing to evaluate these patients. Our study aimed at determining whether a new accelerated diagnostic protocol using sensitive cardiac troponin I (cTnI) 2 hours after admission to the ED followed by stress testing is safe and effective in emergency settings, allowing for appropriate triage, earlier discharge and reducing costs. We conducted a single center randomized trial at Presence St. Francis Hospital Chest pain center in Evanston, Illinois enrolling sixty-four consecutive patients with atypical chest pain and non-diagnostic ECG, participants were randomized to accelerated 2 hrs protocol or our pre-existing 4-hrs protocol. Sixty patients completed the protocol and were randomized to either a 2-hour (29 patients) or 4-hour protocol using both I-STAT and PATHFAST cTnI (31 Patients). Troponin I was evaluated at 0 and at 2 hours from ED presentation with and additional draw for patients in the 4-hour rule out-group. Patients with normal serial biomarkers were then evaluated with stress testing and qualified for earlier discharge if the stress test was negative, while those with a positive biomarker at any time were admitted. Thirty-six patients had exercise treadmill stress test and 24 patients had either nuclear or Echo stress test. Fifty-three patients had a normal stress test and were discharged home. One patient in the 4-hour group with normal serial troponins developed ventricular tachycardia/fibrillation during the recovery period of a regular stress test. Six patients had a positive PATHFAST cTnI and a normal I-STAT cTnI at 2-hours. Two out of these six patients evaluated by coronary angiography. One patient had severe tortuous coronaries but no significant obstructive lesion and one had a severe CAD who needed Coronary artery bypass grafting (CABG). Three of the six patients had a normal stress test and one patient decided to leave without further testing. None of the patients with a normal stress test had a major cardiac event or adverse cardiac outcome at six-month follow up. This study demonstrates that the 2 hours accelerated protocol using high sensitivity Troponin assay at 0 and 2 hours with comprehensive clinical evaluation and ECG followed by stress testing might be successful in identifying low-risk patient population who may benefit from early discharge from ED reducing associated costs and length of stay.

  1. Myocardial injury after noncardiac surgery-incidence and predictors from a prospective observational cohort study at an Indian tertiary care centre.

    PubMed

    George, Rubin; Menon, Vidya P; Edathadathil, Fabia; Balachandran, Sabarish; Moni, Merlin; Sathyapalan, Dipu; Prasanna, Preetha; S, Gokuldas; Paul, Jerry; K K, Chandrababu; Kumar, Lakshmi; Pillai, Ashok

    2018-05-01

    Asymptomatic myocardial injury following noncardiac surgery (MINS) is an independent predictor of 30-day mortality and may go unrecognized based on standard diagnostic definition for myocardial infarction (MI). Given lack of published research on MINS in India, our study aims to determine incidence of MINS in patients undergoing noncardiac surgery at our tertiary care hospital, and evaluate the clinical characteristics including 30-day outcome.The prospective observational study included patients >65 years or >45 years with either hypertension (HTN), diabetes mellitus (DM), coronary artery disease (CAD), cerebrovascular accident (CVA), or peripheral arterial disease undergoing noncardiac surgery. MINS was peak troponin level of ≥0.03 ng/dL at 12-hour or 24-hour postoperative. All patients were followed for 30 days postoperatively. Predictors of MINS and mortality were analyzed using multivariate logistic regression. Patients categorized based on peak troponin cut-off values determined by receiver operating characteristic curve were analyzed by Kaplan-Meir test to compare the survival of patients between the groups.Among 1075 patients screened during 34-month period, the incidence of MINS was 17.5% (188/1075). Patients with DM, CAD, or who underwent peripheral nerve block anaesthesia were 1.5 (P < .01), 2 (P < .001), and 12 (P < .001) times, respectively, more likely to develop MINS than others. Patients with heart rates ≥96 bpm before induction of anesthesia were significantly associated with MINS (P = .005) and mortality (P = .02). The 30-day mortality in MINS cohort was 11.7% (22/188, 95% CI 7.5%-17.2%) vs 2.5% (23/887, 95% CI 1.7%-3.9%) in patients without MINS (P < .001). ECG changes (P = .002), peak troponin values >1 ng/mL (P = .01) were significantly associated with mortality. A peak troponin cut-off of >0.152 ng/mL predicted mortality among MINS patients at 72% sensitivity and 58% specificity. Lack of antithrombotic therapy following MINS was independent predictor of mortality (P < .001), with decreased mortality in patients who took post-op ASA (Aspirin) or Clopidogrel. Mortality among MINS patients with post-op ASA intake is 6.7% vs 12.1% among MINS patients without post-op ASA intake. Mortality among MINS patients with post-op Clopidogrel intake is 10.5% vs 11.8% among MINS patients without post-op Clopidogrel intake.A higher (17.5%, 95% CI 15-19%) incidence of MINS was observed in our patient cohort with significant association with 30-day mortality. Serial postoperative monitoring of troponin following noncardiac surgery as standard of care, would identify "at risk" patients translating to improved outcomes.

  2. Integration of 3D Printed and Micropatterned Polycaprolactone Scaffolds for Guidance of Oriented Collagenous Tissue Formation In Vivo.

    PubMed

    Pilipchuk, Sophia P; Monje, Alberto; Jiao, Yizu; Hao, Jie; Kruger, Laura; Flanagan, Colleen L; Hollister, Scott J; Giannobile, William V

    2016-03-01

    Scaffold design incorporating multiscale cues for clinically relevant, aligned tissue regeneration has potential to improve structural and functional integrity of multitissue interfaces. The objective of this preclinical study is to develop poly(ε-caprolactone) (PCL) scaffolds with mesoscale and microscale architectural cues specific to human ligament progenitor cells and assess their ability to form aligned bone-ligament-cementum complexes in vivo. PCL scaffolds are designed to integrate a 3D printed bone region with a micropatterned PCL thin film consisting of grooved pillars. The patterned film region is seeded with human ligament cells, fibroblasts transduced with bone morphogenetic protein-7 genes seeded within the bone region, and a tooth dentin segment positioned on the ligament region prior to subcutaneous implantation into a murine model. Results indicate increased tissue alignment in vivo using micropatterned PCL films, compared to random-porous PCL. At week 6, 30 μm groove depth significantly enhances oriented collagen fiber thickness, overall cell alignment, and nuclear elongation relative to 10 μm groove depth. This study demonstrates for the first time that scaffolds with combined hierarchical mesoscale and microscale features can align cells in vivo for oral tissue repair with potential for improving the regenerative response of other bone-ligament complexes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Pairwise Sequence Alignment Library

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeff Daily, PNNL

    2015-05-20

    Vector extensions, such as SSE, have been part of the x86 CPU since the 1990s, with applications in graphics, signal processing, and scientific applications. Although many algorithms and applications can naturally benefit from automatic vectorization techniques, there are still many that are difficult to vectorize due to their dependence on irregular data structures, dense branch operations, or data dependencies. Sequence alignment, one of the most widely used operations in bioinformatics workflows, has a computational footprint that features complex data dependencies. The trend of widening vector registers adversely affects the state-of-the-art sequence alignment algorithm based on striped data layouts. Therefore, amore » novel SIMD implementation of a parallel scan-based sequence alignment algorithm that can better exploit wider SIMD units was implemented as part of the Parallel Sequence Alignment Library (parasail). Parasail features: Reference implementations of all known vectorized sequence alignment approaches. Implementations of Smith Waterman (SW), semi-global (SG), and Needleman Wunsch (NW) sequence alignment algorithms. Implementations across all modern CPU instruction sets including AVX2 and KNC. Language interfaces for C/C++ and Python.« less

  4. Direct-write 3D printing of composite materials with magnetically aligned discontinuous reinforcement

    NASA Astrophysics Data System (ADS)

    Martin, Joshua J.; Caunter, Andrew; Dendulk, Amy; Goodrich, Scott; Pembroke, Ryan; Shores, Dan; Erb, Randall M.

    2017-05-01

    Three-dimensional (3D) printing of fiber reinforced composites represents an enabling technology that may bring toughness and specific strength to complex parts. Recently, direct-write 3D printing has been offered as a promising route to manufacturing fiber reinforced composites that show high specific strength. These approaches primarily rely on the use of shear-alignment during the extrusion process to align fibers along the printing direction. Shear alignment prevents fibers from being oriented along principle stress directions of the final designed part. This paper describes a new direct-write style 3D printing system that incorporates magnetic fields to actively control the orientation of reinforcing fibers during the printing of fiber reinforced composites. Such a manufacturing system is fraught with complications from the high shear dominated alignment experienced by the fibers during extrusion to the slow magnetic alignment dynamics of fibers in viscous media. Here we characterize these issues and suggest effective operating windows in which magnetic alignment is a viable approach to orienting reinforcing particles during direct-write 3D printing.

  5. SATCHMO-JS: a webserver for simultaneous protein multiple sequence alignment and phylogenetic tree construction.

    PubMed

    Hagopian, Raffi; Davidson, John R; Datta, Ruchira S; Samad, Bushra; Jarvis, Glen R; Sjölander, Kimmen

    2010-07-01

    We present the jump-start simultaneous alignment and tree construction using hidden Markov models (SATCHMO-JS) web server for simultaneous estimation of protein multiple sequence alignments (MSAs) and phylogenetic trees. The server takes as input a set of sequences in FASTA format, and outputs a phylogenetic tree and MSA; these can be viewed online or downloaded from the website. SATCHMO-JS is an extension of the SATCHMO algorithm, and employs a divide-and-conquer strategy to jump-start SATCHMO at a higher point in the phylogenetic tree, reducing the computational complexity of the progressive all-versus-all HMM-HMM scoring and alignment. Results on a benchmark dataset of 983 structurally aligned pairs from the PREFAB benchmark dataset show that SATCHMO-JS provides a statistically significant improvement in alignment accuracy over MUSCLE, Multiple Alignment using Fast Fourier Transform (MAFFT), ClustalW and the original SATCHMO algorithm. The SATCHMO-JS webserver is available at http://phylogenomics.berkeley.edu/satchmo-js. The datasets used in these experiments are available for download at http://phylogenomics.berkeley.edu/satchmo-js/supplementary/.

  6. Paraplegic patients: how to measure balance and what is normal or functional?

    PubMed

    Barkoh, Kaku; Lucas, Joshua W; Lee, Larry; Hsieh, Patrick C; Wang, Jeffrey C; Rolfe, Kevin

    2018-02-01

    To review the current understanding and data of sagittal balance and alignment considerations in paraplegic patients. A PubMed literature search was conducted to identify all relevant articles relating to sagittal alignment and sagittal balance considerations in paraplegic and spinal cord injury patients. While there are numerous studies and publications on sagittal balance in the ambulatory patient with spinal deformity or complex spine disorders, there is paucity of the literature on "normal" sagittal balance in the paraplegic patients. Studies have reported significantly alterations of the sagittal alignment parameters in the non-ambulatory paraplegic patients compared to ambulatory patients. The variability of the alignment changes is related to the differences in the level of the spinal cord injury and their differences in the activations of truncal muscles to allow functional movements in those patients, particularly in optimizing sitting and transferring. Surgical goal in treating paraplegic patients with complex pathologies should not be solely directed to achieve the "normal" radiographic parameters of sagittal alignment in the ambulatory patients. The goal should be to maintain good coronal balance to allow ideal sitting position and to preserve motion segment to optimize functions of paraplegia patients. Current available literature data have not defined normal sagittal parameters for paraplegic patients. There are significant differences in postural sagittal parameters and muscle activations in paraplegic and non-spinal cord injury patients that can lead to differences in sagittal alignment and balance. Treatment goal in spine surgery for paraplegic patients should address their global function, sitting balance, and ability to perform self-care rather than the accepted radiographic parameters for adult spinal deformity in ambulatory patients.

  7. Statistical inference of protein structural alignments using information and compression.

    PubMed

    Collier, James H; Allison, Lloyd; Lesk, Arthur M; Stuckey, Peter J; Garcia de la Banda, Maria; Konagurthu, Arun S

    2017-04-01

    Structural molecular biology depends crucially on computational techniques that compare protein three-dimensional structures and generate structural alignments (the assignment of one-to-one correspondences between subsets of amino acids based on atomic coordinates). Despite its importance, the structural alignment problem has not been formulated, much less solved, in a consistent and reliable way. To overcome these difficulties, we present here a statistical framework for the precise inference of structural alignments, built on the Bayesian and information-theoretic principle of Minimum Message Length (MML). The quality of any alignment is measured by its explanatory power-the amount of lossless compression achieved to explain the protein coordinates using that alignment. We have implemented this approach in MMLigner , the first program able to infer statistically significant structural alignments. We also demonstrate the reliability of MMLigner 's alignment results when compared with the state of the art. Importantly, MMLigner can also discover different structural alignments of comparable quality, a challenging problem for oligomers and protein complexes. Source code, binaries and an interactive web version are available at http://lcb.infotech.monash.edu.au/mmligner . arun.konagurthu@monash.edu. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  8. Periprocedural ischaemia during recanalisation of chronic total coronary occlusions: the influence of the transcollateral retrograde approach.

    PubMed

    Werner, Gerald S; Coenen, Anja; Tischer, Karl-Heinz

    2014-11-01

    Percutaneous coronary intervention for chronic total coronary occlusions (CTO) becomes increasingly more complex with the transcollateral retrograde approach. This study assesses the effect of the retrograde approach on markers of ischaemia and clinical events. Four hundred and ninety-two consecutive procedures in 392 patients were prospectively evaluated. Before and within 18-24 hours after the PCI creatine kinase (CK) and cardiac troponin I (cTnI) were obtained. A CK increase of greater than three times the upper limit of normal (ULN) was considered a periprocedural MI. Patients with initially elevated cTnI were excluded. In 106 patients with a retrograde wire passage of the septal collaterals, the incidence of a CK or TnI increase was higher as compared to the antegrade group. Patients with septal dilatation or passage of a dilatation catheter (Corsair) showed the highest cTnI. There was no difference in cardiac death or cerebral complications between the groups with antegrade and retrograde approach within the first 30 days. Complex retrograde recanalisation procedures for CTOs lead to an increased periprocedural ischaemic burden, most likely due to obstruction of the collateral pathway, and to the increased plaque burden of complex lesions treated with the retrograde approach.

  9. System Alignment and Consensus Discourses in Reforms: "School Effectiveness Frameworks and Instructional Rounds." Philosophical Responses with Oakeshott, Mouffe and Rancière

    ERIC Educational Resources Information Center

    Stickney, Jeff

    2015-01-01

    In this commentary 26-year Ontario district teacher, Jeff Stickney, begins by surveying balanced approaches to large- and small-scale education reforms: contrasting linear alignment with more complex ecological models, drawing on recent work by Andy Hargreaves (2008; Hargreaves & Shirley, 2012). Next, through a brief case study of School…

  10. Lessons Learned in Systemic District Reform: A Cross-District Analysis from the Comprehensive Aligned Instructional System (CAIS) Benchmarking Study

    ERIC Educational Resources Information Center

    Waters, Louise Bay; Vargo, Merrill

    2008-01-01

    Urban district reform has been hampered by the challenge of understanding and supporting the tremendous complexity of district change. Improving this understanding through actionable, practice-based research is the purpose of this study. The authors began the study with the hypothesis that achieving districts both align their instructional systems…

  11. IT Governance and the Public Sector: A Survey of Perceptions, Attitudes, and Knowledge of Federal Public Sector IT Employees

    ERIC Educational Resources Information Center

    Martin, David P.

    2013-01-01

    IT governance has become an important topic as both public and private organizations struggle to meet the challenge of aligning complex IT systems with operational needs. Without effective IT governance, organizations fail to gain strategic benefits that come by the proper strategic alignment of IT resources with the larger organizational mission.…

  12. Troponins Test

    MedlinePlus

    ... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... test is not approved in the U.S., but research is ongoing and it may become available in ...

  13. Active and Passive Radiative Transfer Modeling with Preferentially-Aligned Particles

    NASA Technical Reports Server (NTRS)

    Adams, Ian Stuart

    2017-01-01

    The fluid dynamics of falling hydrometeors often results in preferential orientations that can affect both the intensity and polarization of electromagnetic radiation. In order to properly interpret remote sensing observations of ice and snow, such alignments should be considered when constructing databases of scattering particles; however, the inclusion of aligned particles increases the complexity of the scattering data. To demonstrate the use of scattering properties of preferentially-aligned particles, millimeter-wave brightness temperatures and radar observables, including reflectivity and linear depolarization ratio, are modeled using the Atmospheric Radiative Transfer Simulator (ARTS). The necessary scattering parameters for vector radiative transfer, particularly with respect to ARTS, are reviewed, and the exploitation of particle symmetries, as well as scattering reciprocity relationships, are detailed.

  14. Automated batch fiducial-less tilt-series alignment in Appion using Protomo

    PubMed Central

    Noble, Alex J.; Stagg, Scott M.

    2015-01-01

    The field of electron tomography has benefited greatly from manual and semi-automated approaches to marker-based tilt-series alignment that have allowed for the structural determination of multitudes of in situ cellular structures as well as macromolecular structures of individual protein complexes. The emergence of complementary metal-oxide semiconductor detectors capable of detecting individual electrons has enabled the collection of low dose, high contrast images, opening the door for reliable correlation-based tilt-series alignment. Here we present a set of automated, correlation-based tilt-series alignment, contrast transfer function (CTF) correction, and reconstruction workflows for use in conjunction with the Appion/Leginon package that are primarily targeted at automating structure determination with cryogenic electron microscopy. PMID:26455557

  15. Biological intuition in alignment-free methods: response to Posada.

    PubMed

    Ragan, Mark A; Chan, Cheong Xin

    2013-08-01

    A recent editorial in Journal of Molecular Evolution highlights opportunities and challenges facing molecular evolution in the era of next-generation sequencing. Abundant sequence data should allow more-complex models to be fit at higher confidence, making phylogenetic inference more reliable and improving our understanding of evolution at the molecular level. However, concern that approaches based on multiple sequence alignment may be computationally infeasible for large datasets is driving the development of so-called alignment-free methods for sequence comparison and phylogenetic inference. The recent editorial characterized these approaches as model-free, not based on the concept of homology, and lacking in biological intuition. We argue here that alignment-free methods have not abandoned models or homology, and can be biologically intuitive.

  16. Subclinical myocardial necrosis and cardiovascular risk in stable patients undergoing elective cardiac evaluation.

    PubMed

    Tang, W H Wilson; Wu, Yuping; Nicholls, Stephen J; Brennan, Danielle M; Pepoy, Michael; Mann, Shirley; Pratt, Alan; Van Lente, Frederick; Hazen, Stanley L

    2010-03-01

    The presence of subclinical myocardial necrosis as a prodrome to longer-term adverse cardiac event risk has been debated. The debate has focused predominantly within patients with acute coronary syndrome, and on issues of troponin assay variability and accuracy of detection, rather than on the clinical significance of the presence of subclinical myocardial necrosis (ie, "troponin leak") within stable cardiac patients. Herein, we examine the relationship between different degrees of subclinical myocardial necrosis and long-term adverse clinical outcomes within a stable cardiac patient population with essentially normal renal function. Sequential consenting patients (N=3828; median creatinine clearance, 100 mL/min/1.73m(2)) undergoing elective diagnostic coronary angiography with cardiac troponin I (cTnI) levels below the diagnostic cut-off for defining myocardial infarction (<0.03 ng/mL) were evaluated. The relationship of subclinical myocardial necrosis with incident major adverse cardiovascular events (defined as any death, myocardial infarction, or stroke) over 3-year follow-up was examined. "Probable" (cTnI 0.001-0.008 ng/mL) and "definite" (cTnI 0.009-0.029 ng/mL) subclinical myocardial necrosis were observed frequently within the cohort (34% and 18%, respectively). A linear relationship was observed between the magnitude of subclinical myocardial necrosis and risk of 3-year incident major adverse cardiovascular events, particularly in those with cTnI 0.009 ng/mL or higher (hazard ratio, 3.00; 95% confidence interval, 2.4-3.8), even after adjustment for traditional risk factors, C-reactive protein, and creatinine clearance. The presence of subclinical myocardial necrosis was associated with elevations in acute phase proteins (C-reactive protein, ceruloplasmin; P<0.01 each) and reduction in systemic antioxidant enzyme activities (arylesterase; P<0.01) but showed no significant associations with multiple specific measures of oxidant stress, and showed borderline associations with myeloperoxidase, a marker of leukocyte activation. In stable cardiology patients, prodromal subclinical myocardial necrosis is associated with substantially higher long-term risk for major adverse cardiovascular events. The underlying mechanisms contributing to this minimal troponin leak phenomenon warrants further investigation.

  17. Myofilament Calcium Sensitivity: Mechanistic Insight into TnI Ser-23/24 and Ser-150 Phosphorylation Integration

    PubMed Central

    Salhi, Hussam E.; Hassel, Nathan C.; Siddiqui, Jalal K.; Brundage, Elizabeth A.; Ziolo, Mark T.; Janssen, Paul M. L.; Davis, Jonathan P.; Biesiadecki, Brandon J.

    2016-01-01

    Troponin I (TnI) is a major regulator of cardiac muscle contraction and relaxation. During physiological and pathological stress, TnI is differentially phosphorylated at multiple residues through different signaling pathways to match cardiac function to demand. The combination of these TnI phosphorylations can exhibit an expected or unexpected functional integration, whereby the function of two phosphorylations are different than that predicted from the combined function of each individual phosphorylation alone. We have shown that TnI Ser-23/24 and Ser-150 phosphorylation exhibit functional integration and are simultaneously increased in response to cardiac stress. In the current study, we investigated the functional integration of TnI Ser-23/24 and Ser-150 to alter cardiac contraction. We hypothesized that Ser-23/24 and Ser-150 phosphorylation each utilize distinct molecular mechanisms to alter the TnI binding affinity within the thin filament. Mathematical modeling predicts that Ser-23/24 and Ser-150 phosphorylation affect different TnI affinities within the thin filament to distinctly alter the Ca2+-binding properties of troponin. Protein binding experiments validate this assertion by demonstrating pseudo-phosphorylated Ser-150 decreases the affinity of isolated TnI for actin, whereas Ser-23/24 pseudo-phosphorylation is not different from unphosphorylated. Thus, our data supports that TnI Ser-23/24 affects TnI-TnC binding, while Ser-150 phosphorylation alters TnI-actin binding. By measuring force development in troponin-exchanged skinned myocytes, we demonstrate that the Ca2+ sensitivity of force is directly related to the amount of phosphate present on TnI. Furthermore, we demonstrate that Ser-150 pseudo-phosphorylation blunts Ser-23/24-mediated decreased Ca2+-sensitive force development whether on the same or different TnI molecule. Therefore, TnI phosphorylations can integrate across troponins along the myofilament. These data demonstrate that TnI Ser-23/24 and Ser-150 phosphorylation regulates muscle contraction in part by modulating different TnI interactions in the thin filament and it is the combination of these differential mechanisms that provides understanding of their functional integration. PMID:28018230

  18. Natriuretic Peptide and High-Sensitivity Troponin for Cardiovascular Risk Prediction in Diabetes: The Atherosclerosis Risk in Communities (ARIC) Study

    PubMed Central

    Gori, Mauro; Gupta, Deepak K.; Claggett, Brian; Selvin, Elizabeth; Folsom, Aaron R.; Matsushita, Kunihiro; Bello, Natalie A.; Cheng, Susan; Shah, Amil; Skali, Hicham; Vardeny, Orly; Ni, Hanyu; Ballantyne, Christie M.; Astor, Brad C.; Klein, Barbara E.; Aguilar, David

    2016-01-01

    OBJECTIVE Cardiovascular disease (CVD) is the major cause of morbidity and mortality in diabetes; yet, heterogeneity in CVD risk has been suggested in diabetes, providing a compelling rationale for improving diabetes risk stratification. We hypothesized that N-terminal prohormone brain natriuretic peptide (NTproBNP) and high-sensitivity troponin T may enhance CVD risk stratification beyond commonly used markers of risk and that CVD risk is heterogeneous in diabetes. RESEARCH DESIGN AND METHODS Among 8,402 participants without prevalent CVD at visit 4 (1996–1998) of the Atherosclerosis Risk in Communities (ARIC) study there were 1,510 subjects with diabetes (mean age 63 years, 52% women, 31% African American, and 60% hypertensive). RESULTS Over a median follow-up of 13.1 years, there were 540 incident fatal/nonfatal CVD events (coronary heart disease, heart failure, and stroke). Both troponin T ≥14 ng/L (hazard ratio [HR] 1.96 [95% CI 1.57–2.46]) and NTproBNP >125 pg/mL (1.61 [1.29–1.99]) were independent predictors of incident CVD events at multivariable Cox proportional hazard models. Addition of circulating cardiac biomarkers to traditional risk factors, abnormal electrocardiogram (ECG), and conventional markers of diabetes complications including retinopathy, nephropathy, and peripheral arterial disease significantly improved CVD risk prediction (net reclassification index 0.16 [95% CI 0.07–0.22]). Compared with individuals without diabetes, subjects with diabetes had 1.6-fold higher adjusted risk of incident CVD. However, participants with diabetes with normal cardiac biomarkers and no conventional complications/abnormal ECG (n = 725 [48%]) were at low risk (HR 1.12 [95% CI 0.95–1.31]), while those with abnormal cardiac biomarkers, alone (n = 186 [12%]) or in combination with conventional complications/abnormal ECG (n = 243 [16%]), were at greater risk (1.99 [1.59–2.50] and 2.80 [2.34–3.35], respectively). CONCLUSIONS Abnormal levels of NTproBNP and troponin T may help to distinguish individuals with high diabetes risk from those with low diabetes risk, providing incremental risk prediction beyond commonly used markers of risk. PMID:26740635

  19. The impact of intermittent exercise in a hypoxic environment on redox status and cardiac troponin release in the serum of well-trained marathon runners.

    PubMed

    Li, Feifei; Nie, Jinlei; Lu, Yifan; Tong, Tom Kwok Keung; Yi, Longyan; Yan, Huiping; Fu, Frank Hoo Kin; Ma, Shengxia

    2016-10-01

    To investigate the effects of hypoxic training on redox status and cardiac troponin (cTn) release after intermittent exercise. Nine well-trained male marathon runners (age, 21.7 ± 2.3 year; body mass, 64.7 ± 4.8 kg; height, 177.9 ± 3.8 cm; and VO2max, 64.3 ± 6.7 ml kg(-1) min(-1)) completed intermittent exercise under normoxic [trial N; fraction of inspiration oxygen (FIO2), 21.0 %] and hypoxic (trial H; FIO2, 14.4 %) conditions in random order. Each bout of intermittent exercise included hard run (16.2 ± 0.8 km h(-1)) at 90 % VO2max for 2 min followed by easy run (9.0 ± 0.4 km h(-1)) at 50 % VO2max for 2 min and 23 bouts in 92 min totally. Malondialdehyde, reduced glutathione (GSH), superoxide dismutase, an estimate of total antioxidant capacity (T-AOC), high-sensitivity cardiac troponin T (hs-cTnT), and cardiac troponin I (cTnI) were measured before, immediately after (0 h), and 2, 4, and 24 h after the completion of trials N and H. GSH was increased immediately after trial N. T-AOC was lower 4 h after trial H than trial N. Hs-cTnT was elevated from 0 to 4 h and returned to baseline 24 h after both trials. CTnI was increased after trial H; peaked at 2-4 h and returned to below the detection by 24 h. The overall redox status was balanced under normoxic conditions, and exercise-induced cTn release did not deviate. However, the protective effects of antioxidant were weaker in the hypoxic state than normoxic, and the stress on the myocardium induced by intermittent exercise was transiently aggravated.

  20. Implementation of high sensitivity cardiac troponin T measurement in the emergency department.

    PubMed

    Christ, Michael; Popp, Steffen; Pohlmann, Hella; Poravas, Michail; Umarov, Dina; Bach, Ruth; Bertsch, Thomas

    2010-12-01

    we examined the diagnostic performance of high sensitivity cardiac troponin T (cTnThs) measurement and its ability to predict risk in unselected patients presenting to the emergency department with acute chest pain. we conducted a retrospective analysis of 137 consecutive patients with chest pain (age range, 66 ± 16 years; 64% male). A final diagnosis of acute myocardial infarction was made using the "old" (cTnT fourth-generation assay, ≥ 0.04 microg/L) or the "new" cutpoint (cTnThs ≥ 0.014 microg/L). the adjudicated final diagnosis of acute myocardial infarction significantly increased from 20 to 35 patients (a 75% increase) and troponin-positive nonvascular cardiac chest pain from 10 to 30 (a 200% increase) using cTnThs. The number of patients with unstable angina or troponin-negative nonvascular cardiac chest pain significantly decreased (P <.05). Diagnostic performance of cTnThs levels at admission was significantly higher compared to cTnT levels (area under the curve [AUC] 0.85 vs AUC 0.70; P <.05). cTnThs levels below the detection limit (<0.003 microg/L) had a negative predictive value of 100% to exclude acute myocardial infarction. The event rate during 6 months of follow-up was low in patients with cTnThs levels <0.014 microg/L, while patients with cTnT levels ≥ 0.04 μg/L were at increased, and patients with cTnThs ≥ 0.014 μg/L and cTnT <0.04 microg/L at intermediate risk of death or recurrent myocardial infarction (P = .002). Risk was highest in chest pain patients with dynamic changes of cTnThs levels >30%. the introduction of cTnThs assay displays an excellent diagnostic performance for the workup of patients with chest pain at the time of their initial presentation. Even small increases of cTnThs indicate increased risk for death or myocardial infarction during follow-up. © 2010 Elsevier Inc. All rights reserved.

  1. Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations.

    PubMed

    Irfan, Affan; Reichlin, Tobias; Twerenbold, Raphael; Meister, Marc; Moehring, Berit; Wildi, Karin; Bassetti, Stefano; Zellweger, Christa; Gimenez, Maria Rubini; Hoeller, Rebeca; Murray, Karsten; Sou, Seoung Mann; Mueller, Mira; Mosimann, Tamina; Reiter, Miriam; Haaf, Philip; Ziller, Ronny; Freidank, Heike; Osswald, Stefan; Mueller, Christian

    2013-09-01

    Absolute changes in high-sensitivity cardiac troponin T (hs-cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high-sensitivity cardiac troponin I (hs-cTnI) assays and whether the combination of absolute and relative change might further increase accuracy. In a prospective, international multicenter study, high-sensitivity cardiac troponin (hs-cTn) was measured with 3 novel assays (hs-cTnT, Roche Diagnostics Corp, Indianapolis, Ind; hs-cTnI, Beckman Coulter Inc, Brea, Calif; hs-cTnI, Siemens, Munich, Germany) in a blinded fashion at presentation and after 1 and 2 hours in a blinded fashion in 830 unselected patients with suspected acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. The area under the receiver operating characteristic curve for diagnosing acute myocardial infarction was significantly higher for 1- and 2-hour absolute versus relative hs-cTn changes for all 3 assays (P < .001). The area under the receiver operating characteristic curve of the combination of 2-hour absolute and relative change (hs-cTnT 0.98 [95% confidence interval {CI}, 0.97-0.99]; hs-cTnI, Beckman Coulter Inc, 0.97 [95% CI, 0.96-0.99]; hs-cTnI, Siemens, 0.96 [95% CI, 0.93-0.99]) were high and provided some benefit compared with the use of absolute change alone for hs-cTnT, but not for the hs-cTnI assays. Reclassification analysis confirmed the superiority of absolute changes versus relative changes. Absolute changes seem to be the preferred metrics for both hs-cTnT and hs-cTnI in the early diagnosis of acute myocardial infarction. The combination of absolute and relative changes provides a small added value for hs-cTnT, but not for hs-cTnI. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Beyond triage: the diagnostic accuracy of emergency department nursing staff risk assessment in patients with suspected acute coronary syndromes.

    PubMed

    Carlton, Edward Watts; Khattab, Ahmed; Greaves, Kim

    2016-02-01

    To establish the accuracy of emergency department (ED) nursing staff risk assessment using an established chest pain risk score alone and when incorporated with presentation high-sensitivity troponin testing as part of an accelerated diagnostic protocol (ADP). Prospective observational study comparing nursing and physician risk assessment using the modified Goldman (m-Goldman) score and a predefined ADP, incorporating presentation high-sensitivity troponin. A UK District ED. Consecutive patients, aged ≥18, with suspected cardiac chest pain and non-ischaemic ECG, for whom the treating physician determined serial troponin testing was required. 30-day major adverse cardiac events (MACE). 960 participants were recruited. 912/960 (95.0%) had m-Goldman scores recorded by physicians and 745/960 (77.6%) by nursing staff. The area under the curve of the m-Goldman score in predicting 30-day MACE was 0.647 (95% CI 0.594 to 0.700) for physicians and 0.572 (95% CI 0.510 to 0.634) for nursing staff (p=0.09). When incorporated into an ADP, sensitivity for the rule-out of MACE was 99.2% (95% CI 94.8% to 100%) and 96.7% (90.3% to 99.2%) for physicians and nurses, respectively. One patient in the physician group (0.3%) and three patients (1.1%) in the nursing group were classified as low risk yet had MACE. There was fair agreement in the identification of low-risk patients (kappa 0.31, 95% CI 0.24 to 0.38). The diagnostic accuracy of ED nursing staff risk assessment is similar to that of ED physicians and interobserver reliability between assessor groups is fair. When incorporating high-sensitivity troponin testing, a nurse-led ADP has a miss rate of 1.1% for MACE at 30 days. Controlled Trials Database (ISRCTN no. 21109279). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Comparing serum levels of cardiac biomarkers in cancer patients receiving chemotherapy and subjects with chronic periodontitis

    PubMed Central

    2012-01-01

    Background Chronic periodontitis (CP) is a chronic inflammation associated with elevations of several inflammatory and cardiac markers. Studies implicated CP as one of the etiologies in coronary heart disease (CHD). Cardiotoxicity is a major complication of anticancer drugs, including anthracyclines and 5-fluorouracil (5FU). The most severe cardiac complications are heart failure, arrhythmia and coronary heart disease (CHD). In this study, we compared the level of inflammatory factors and cardiac markers between chronic periodontitis patients and cancer patients receiving chemotherapy. Methods 108 blood samples of periodontally healthy subjects were obtained on random from Hong Kong Red Cross, and these represented the controlled population. Forty-four patients diagnosed with chronic periodontitis were recruited from the West China Hospital of Stomatology, Sichuan University. They have received scaling and root planning with mean pocket depths of 6.05 mm. Thirty breast cancer patients diagnosed with invasive ductal carcinoma from UNIMED Medical Institute, Hong Kong gave consent to participate in this study. They received 4 cycles of 500mg/m2 5-fluorouracil, 75 mg/m2 epirubicin and 500mg/m2 cyclophosphamide at a 3-week interval between each cycle. Peripheral venous blood from each group was taken for measurement of blood cells, inflammatory marker (P-selectin, high sensitvity C-reactive protein) and cardiac markers (troponin T; troponin I; N-terminal pro brain natriuretic peptide (Nt-proBNP) and Lactate dehydrogenase (LDH). Results The lymphocyte count was higher (p < 0.05) in periodontitis patients than the other two groups, and more neutrophils (p < 0.05) were seen in cancer patients receiving chemotherapy. The two test groups demonstrated higher levels (p < 0.01) of inflammatory and cardiac markers than the control group. Conclusions The elevated cardiac markers found in periodontitis patients suggested that they may carry potential risks in developing cardiac lesions. Troponin T, troponin I, pro-BNP, LDH and high sensitvity C-reactive protein may be used as markers to monitor cardiac lesions in chronic inflammatory patients. PMID:23046680

  4. Optimal network alignment with graphlet degree vectors.

    PubMed

    Milenković, Tijana; Ng, Weng Leong; Hayes, Wayne; Przulj, Natasa

    2010-06-30

    Important biological information is encoded in the topology of biological networks. Comparative analyses of biological networks are proving to be valuable, as they can lead to transfer of knowledge between species and give deeper insights into biological function, disease, and evolution. We introduce a new method that uses the Hungarian algorithm to produce optimal global alignment between two networks using any cost function. We design a cost function based solely on network topology and use it in our network alignment. Our method can be applied to any two networks, not just biological ones, since it is based only on network topology. We use our new method to align protein-protein interaction networks of two eukaryotic species and demonstrate that our alignment exposes large and topologically complex regions of network similarity. At the same time, our alignment is biologically valid, since many of the aligned protein pairs perform the same biological function. From the alignment, we predict function of yet unannotated proteins, many of which we validate in the literature. Also, we apply our method to find topological similarities between metabolic networks of different species and build phylogenetic trees based on our network alignment score. The phylogenetic trees obtained in this way bear a striking resemblance to the ones obtained by sequence alignments. Our method detects topologically similar regions in large networks that are statistically significant. It does this independent of protein sequence or any other information external to network topology.

  5. Retention time alignment of LC/MS data by a divide-and-conquer algorithm.

    PubMed

    Zhang, Zhongqi

    2012-04-01

    Liquid chromatography-mass spectrometry (LC/MS) has become the method of choice for characterizing complex mixtures. These analyses often involve quantitative comparison of components in multiple samples. To achieve automated sample comparison, the components of interest must be detected and identified, and their retention times aligned and peak areas calculated. This article describes a simple pairwise iterative retention time alignment algorithm, based on the divide-and-conquer approach, for alignment of ion features detected in LC/MS experiments. In this iterative algorithm, ion features in the sample run are first aligned with features in the reference run by applying a single constant shift of retention time. The sample chromatogram is then divided into two shorter chromatograms, which are aligned to the reference chromatogram the same way. Each shorter chromatogram is further divided into even shorter chromatograms. This process continues until each chromatogram is sufficiently narrow so that ion features within it have a similar retention time shift. In six pairwise LC/MS alignment examples containing a total of 6507 confirmed true corresponding feature pairs with retention time shifts up to five peak widths, the algorithm successfully aligned these features with an error rate of 0.2%. The alignment algorithm is demonstrated to be fast, robust, fully automatic, and superior to other algorithms. After alignment and gap-filling of detected ion features, their abundances can be tabulated for direct comparison between samples.

  6. The Role of Social Identity Complexity in Inter-Group Attitudes among Young Adolescents

    ERIC Educational Resources Information Center

    Knifsend, Casey A.; Juvonen, Jaana

    2013-01-01

    To supplement research on adolescent social identities, the current study examined how social identity complexity relates to ethnic inter-group attitudes in a young adolescent sample (N = 97; "age range" = 12-14 years). Social identity complexity refers to the perceived overlap of groups with which youth align themselves. Descriptive…

  7. Rod-Shaped Neural Units for Aligned 3D Neural Network Connection.

    PubMed

    Kato-Negishi, Midori; Onoe, Hiroaki; Ito, Akane; Takeuchi, Shoji

    2017-08-01

    This paper proposes neural tissue units with aligned nerve fibers (called rod-shaped neural units) that connect neural networks with aligned neurons. To make the proposed units, 3D fiber-shaped neural tissues covered with a calcium alginate hydrogel layer are prepared with a microfluidic system and are cut in an accurate and reproducible manner. These units have aligned nerve fibers inside the hydrogel layer and connectable points on both ends. By connecting the units with a poly(dimethylsiloxane) guide, 3D neural tissues can be constructed and maintained for more than two weeks of culture. In addition, neural networks can be formed between the different neural units via synaptic connections. Experimental results indicate that the proposed rod-shaped neural units are effective tools for the construction of spatially complex connections with aligned nerve fibers in vitro. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Pragmatic approach to chest pain patients discharged with undetectable high-sensitivity troponin T and normal electrocardiogram: the STABS + CT protocol.

    PubMed

    Bishop, Warrick; Girao, Gary

    2017-06-01

    A strategy that discharges chest pain patients with negative high-sensitivity troponin and non-ischaemic electrocardiography changes may still result in 0.44% of patients experiencing myocardial infarction within 30 days. We observed that a pragmatic approach that systematically discharged 25 patients on cardio-protective medications of aspirin, metoprolol and atorvastatin followed with prompt (<10 days) coronary computed tomography angiography resulted in no major adverse cardiac event and adverse drug reaction 30 days post-presentation. The strategy resulted in three patients (12%) ultimately diagnosed with likely unstable angina, which required planned coronary intervention in two patients and medical management in one patient. No unplanned readmissions for chest pains were noted from initial presentation through to 6-month follow up. © 2017 Royal Australasian College of Physicians.

  9. Manipulating the cell differentiation through lentiviral vectors.

    PubMed

    Coppola, Valeria; Galli, Cesare; Musumeci, Maria; Bonci, Désirée

    2010-01-01

    The manipulation of cell differentiation is important to create new sources for the treatment of degenerative diseases or solve cell depletion after aggressive therapy against cancer. In this chapter, the use of a tissue-specific promoter lentiviral vector to obtain a myocardial pure lineage from murine embryonic stem cells (mES) is described in detail. Since the cardiac isoform of troponin I gene product is not expressed in skeletal or other muscle types, short mouse cardiac troponin proximal promoter is used to drive reporter genes. Cells are infected simultaneously with two lentiviral vectors, the first expressing EGFP to monitor the transduction efficiency, and the other expressing a puromycin resistance gene to select the specific cells of interest. This technical approach describes a method to obtain a pure cardiomyocyte population and can be applied to other lineages of interest.

  10. Some distinctive features of zebrafish myogenesis based on unexpected distributions of the muscle cytoskeletal proteins actin, myosin, desmin, alpha-actinin, troponin and titin.

    PubMed

    Costa, Manoel L; Escaleira, Roberta C; Rodrigues, Viviane B; Manasfi, Muhamed; Mermelstein, Claudia S

    2002-08-01

    The current myofibrillogenesis model is based mostly on in vitro cell cultures and on avian and mammalian embryos in situ. We followed the expression of actin, myosin, desmin, alpha-actinin, titin, and troponin using immunofluorescence microscopy of zebrafish (Danio rerio) embryos. We could see young mononucleated myoblasts with sharp striations. The striations were positive for all the sarcomeric proteins. Desmin distribution during muscle maturation changes from dispersed aggregates to a perinuclear concentration to striated afterwards. We could not observe desmin-positive, myofibrillar-proteins-negative cells, and we could not find any non-striated distribution of sarcomeric proteins, such as stress fiber-like structures. Some steps, like fusion before striation, seem to be different in the zebrafish when compared with the previously described myogenesis sequences.

  11. Cross-sectional study of high-sensitivity cardiac troponins T and I in a hospital and community outpatient setting.

    PubMed

    Potter, Julia M; Simpson, Aaron J; Kerrigan, Jennifer; Southcott, Emma; Salib, Marie M; Koerbin, Gus; Hickman, Peter E

    2017-02-01

    Cardiac troponins are specific for the heart, but not for the acute coronary syndrome. We wanted to assess how common elevated cardiac troponin concentrations were, in a population with significant non-cardiac disease. We measured both hs-cTnT and hs-cTnI on all samples submitted to the laboratory during one 24h period, and assessed the magnitude of the cTn concentration with the location and severity of disease of the patient. Community patients and patients from the maternity ward had the lowest cTn concentrations with results above the 99th percentile being only 0-2% of the total. As expected, the highest proportion of results >99th percentile came from Coronary Care and Intensive Care. However, substantial numbers of persons on Medical and Surgical wards, without a primary diagnosis of cardiac disease, also had cTn >99th percentile. Particularly for cTnT, there was a highly significant odds ratio predicting mortality when results above and below the 99th percentile were compared. Significant illnesses apart from the acute coronary syndrome are important causes of a rise in cTn to above the 99th percentile, and appear to reflect the total body burden of disease. Even when the high hs-cTn concentration is not due to the acute coronary syndrome, there is a significant association with all-cause mortality. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Molecular evaluation of five cardiac genes in Doberman Pinschers with dilated cardiomyopathy.

    PubMed

    Meurs, Kathryn M; Hendrix, Kristina P; Norgard, Michelle M

    2008-08-01

    To sequence the exonic and splice site regions of 5 cardiac genes associated with the human form of familial dilated cardiomyopathy (DCM) in Doberman Pinschers with DCM and to identify a causative mutation. 5 unrelated Doberman Pinschers with DCM and 2 unaffected Labrador Retrievers (control dogs). Exonic and splice site regions of the 5 genes encoding the cardiac proteins troponin C, lamin A/C, cysteine- and glycine-rich protein 3, cardiac troponin T, and the beta-myosin heavy chain were sequenced. Sequences were compared for nucleotide changes between affected dogs and the published canine sequences and 2 control dogs. Base pair changes were considered to be causative for DCM if they were present in an affected dog but not in the control dogs or published sequences and if they involved a conserved amino acid and changed that amino acid to a different polarity, acid-base status, or structure. A causative mutation for DCM in Doberman Pinschers was not identified, although single nucleotide polymorphisms were detected in some dogs in the cysteine- and glycine-rich protein 3, beta-myosin heavy chain, and troponin T genes. Mutations in 5 of the cardiac genes associated with the development of DCM in humans did not appear to be causative for DCM in Doberman Pinschers. Continued evaluation of additional candidate genes or a focused approach with an association analysis is warranted to elucidate the molecular cause of this important cardiac disease in Doberman Pinschers.

  13. Predicting short term mortality after investigation for venous thromboembolism.

    PubMed

    Hogg, Kerstin; Hinchliffe, Edward; Haslam, Shonagh; Sethi, Bilal; Carrier, Marc; Lecky, Fiona

    2013-04-01

    Deaths following diagnosis of venous thromboembolism (VTE) often result from another concurrent illness. The specificity of mortality markers predicting death from pulmonary embolism is unknown. The aim of this analysis was to compare blood predictors of death in patients with confirmed VTE to patients with negative investigations for VTE. Consecutive patients investigated for VTE were prospectively consented from a single hospital over 9months. VTE was diagnosed and excluded with a standard diagnostic algorithm. Blood was drawn for biomarker analysis and analyzed in batches for NT-proBNP, high sensitivity troponin T, C-reactive protein (CRP), fatty acid binding protein (FABP) and ischemia modified albumin (IMA). Participants were followed for 3months. The cohort was analyzed in two groups: those diagnosed with VTE and those who had thrombosis excluded. Regression analysis for 3-month mortality was performed for each group. 16/153 patients diagnosed with VTE died within three months (10.5%) as did 23/606 patients who had negative investigations for VTE (3.8%). Predictors for death following VTE included cancer, NT-proBNP, troponin T, FABP, and Hb<95g/L. NT-proBNP>500pg/ml in acute cancer associated VTE predicted death with C-statistic of 0.89 (0.80-0.99). Cancer, NT-proBNP and troponin T also predicted death in patients with negative investigations for VTE. Several blood markers are not specific for death from PE and may be surrogate markers of global declining health. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Evaluation of Cardiac Toxicity Biomarkers in Rats from Different Laboratories.

    PubMed

    Kim, Kyuri; Chini, Naseem; Fairchild, David G; Engle, Steven K; Reagan, William J; Summers, Sandra D; Mirsalis, Jon C

    2016-12-01

    There is a great need for improved diagnostic and prognostic accuracy of potential cardiac toxicity in drug development. This study reports the evaluation of several commercially available biomarker kits by 3 institutions (SRI, Eli Lilly, and Pfizer) for the discrimination between myocardial degeneration/necrosis and cardiac hypertrophy as well as the assessment of the interlaboratory and interplatform variation in results. Serum concentrations of natriuretic peptides (N-terminal pro-atrial natriuretic peptide [NT-proANP] and N-terminal pro-brain natriuretic peptide [NT-proBNP]), cardiac and skeletal troponins (cTnI, cTnT, and sTnI), myosin light chain 3 (Myl3), and fatty acid binding protein 3 (FABP3) were assessed in rats treated with minoxidil (MNX) and isoproterenol (ISO). MNX caused increased heart-to-body weight ratios and prominent elevations in NT-proANP and NT-proBNP concentrations detected at 24-hr postdose without elevation in troponins, Myl3, or FABP3 and with no abnormal histopathological findings. ISO caused ventricular leukocyte infiltration, myocyte fibrosis, and necrosis with increased concentrations of the natriuretic peptides, cardiac troponins, and Myl3. These results reinforce the advantages of a multimarker strategy in elucidating the underlying cause of cardiac insult and detecting myocardial tissue damage at 24-hr posttreatment. The interlaboratory and interplatform comparison analyses also showed that the data obtained from different laboratories and platforms are highly correlated and reproducible, making these biomarkers widely applicable in preclinical studies.

  15. Children's Reasoning about Spatial Relational Similarity: The Effect of Alignment and Relational Complexity

    ERIC Educational Resources Information Center

    Hribar, Alenka; Haun, Daniel B. M.; Call, Josep

    2012-01-01

    We investigated 4- and 5-year-old children's mapping strategies in a spatial task. Children were required to find a picture in an array of three identical cups after observing another picture being hidden in another array of three cups. The arrays were either aligned one behind the other in two rows or placed side by side forming one line.…

  16. Content and Alignment of State Writing Standards and Assessments as Predictors of Student Writing Achievement: An Analysis of 2007 National Assessment of Educational Progress Data

    ERIC Educational Resources Information Center

    Troia, Gary A.; Olinghouse, Natalie G.; Zhang, Mingcai; Wilson, Joshua; Stewart, Kelly A.; Mo, Ya; Hawkins, Lisa

    2018-01-01

    We examined the degree to which content of states' writing standards and assessments (using measures of content range, frequency, balance, and cognitive complexity) and their alignment were related to student writing achievement on the 2007 National Assessment of Educational Progress (NAEP), while controlling for student, school, and state…

  17. Automated batch fiducial-less tilt-series alignment in Appion using Protomo.

    PubMed

    Noble, Alex J; Stagg, Scott M

    2015-11-01

    The field of electron tomography has benefited greatly from manual and semi-automated approaches to marker-based tilt-series alignment that have allowed for the structural determination of multitudes of in situ cellular structures as well as macromolecular structures of individual protein complexes. The emergence of complementary metal-oxide semiconductor detectors capable of detecting individual electrons has enabled the collection of low dose, high contrast images, opening the door for reliable correlation-based tilt-series alignment. Here we present a set of automated, correlation-based tilt-series alignment, contrast transfer function (CTF) correction, and reconstruction workflows for use in conjunction with the Appion/Leginon package that are primarily targeted at automating structure determination with cryogenic electron microscopy. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A simplified implementation of edge detection in MATLAB is faster and more sensitive than fast fourier transform for actin fiber alignment quantification.

    PubMed

    Kemeny, Steven Frank; Clyne, Alisa Morss

    2011-04-01

    Fiber alignment plays a critical role in the structure and function of cells and tissues. While fiber alignment quantification is important to experimental analysis and several different methods for quantifying fiber alignment exist, many studies focus on qualitative rather than quantitative analysis perhaps due to the complexity of current fiber alignment methods. Speed and sensitivity were compared in edge detection and fast Fourier transform (FFT) for measuring actin fiber alignment in cells exposed to shear stress. While edge detection using matrix multiplication was consistently more sensitive than FFT, image processing time was significantly longer. However, when MATLAB functions were used to implement edge detection, MATLAB's efficient element-by-element calculations and fast filtering techniques reduced computation cost 100 times compared to the matrix multiplication edge detection method. The new computation time was comparable to the FFT method, and MATLAB edge detection produced well-distributed fiber angle distributions that statistically distinguished aligned and unaligned fibers in half as many sample images. When the FFT sensitivity was improved by dividing images into smaller subsections, processing time grew larger than the time required for MATLAB edge detection. Implementation of edge detection in MATLAB is simpler, faster, and more sensitive than FFT for fiber alignment quantification.

  19. EPE analysis of sub-N10 BEoL flow with and without fully self-aligned via using Coventor SEMulator3D

    NASA Astrophysics Data System (ADS)

    Franke, Joern-Holger; Gallagher, Matt; Murdoch, Gayle; Halder, Sandip; Juncker, Aurelie; Clark, William

    2017-03-01

    During the last few decades, the semiconductor industry has been able to scale device performance up while driving costs down. What started off as simple geometrical scaling, driven mostly by advances in lithography, has recently been accompanied by advances in processing techniques and in device architectures. The trend to combine efforts using process technology and lithography is expected to intensify, as further scaling becomes ever more difficult. One promising component of future nodes are "scaling boosters", i.e. processing techniques that enable further scaling. An indispensable component in developing these ever more complex processing techniques is semiconductor process modeling software. Visualization of complex 3D structures in SEMulator3D, along with budget analysis on film thicknesses, CD and etch budgets, allow process integrators to compare flows before any physical wafers are run. Hundreds of "virtual" wafers allow comparison of different processing approaches, along with EUV or DUV patterning options for defined layers and different overlay schemes. This "virtual fabrication" technology produces massively parallel process variation studies that would be highly time-consuming or expensive in experiment. Here, we focus on one particular scaling booster, the fully self-aligned via (FSAV). We compare metal-via-metal (mevia-me) chains with self-aligned and fully-self-aligned via's using a calibrated model for imec's N7 BEoL flow. To model overall variability, 3D Monte Carlo modeling of as many variability sources as possible is critical. We use Coventor SEMulator3D to extract minimum me-me distances and contact areas and show how fully self-aligned vias allow a better me-via distance control and tighter via-me contact area variability compared with the standard self-aligned via (SAV) approach.

  20. Factors driving physician-hospital alignment in orthopaedic surgery.

    PubMed

    Page, Alexandra E; Butler, Craig A; Bozic, Kevin J

    2013-06-01

    The relationships between physicians and hospitals are viewed as central to the proposition of delivering high-quality health care at a sustainable cost. Over the last two decades, major changes in the scope, breadth, and complexities of these relationships have emerged. Despite understanding the need for physician-hospital alignment, identification and understanding the incentives and drivers of alignment prove challenging. Our review identifies the primary drivers of physician alignment with hospitals from both the physician and hospital perspectives. Further, we assess the drivers more specific to motivating orthopaedic surgeons to align with hospitals. We performed a comprehensive literature review from 1992 to March 2012 to evaluate published studies and opinions on the issues surrounding physician-hospital alignment. Literature searches were performed in both MEDLINE(®) and Health Business™ Elite. Available literature identifies economic and regulatory shifts in health care and cultural factors as primary drivers of physician-hospital alignment. Specific to orthopaedics, factors driving alignment include the profitability of orthopaedic service lines, the expense of implants, and issues surrounding ambulatory surgery centers and other ancillary services. Evolving healthcare delivery and payment reforms promote increased collaboration between physicians and hospitals. While economic incentives and increasing regulatory demands provide the strongest drivers, cultural changes including physician leadership and changing expectations of work-life balance must be considered when pursuing successful alignment models. Physicians and hospitals view each other as critical to achieving lower-cost, higher-quality health care.

  1. A new graph-based method for pairwise global network alignment

    PubMed Central

    Klau, Gunnar W

    2009-01-01

    Background In addition to component-based comparative approaches, network alignments provide the means to study conserved network topology such as common pathways and more complex network motifs. Yet, unlike in classical sequence alignment, the comparison of networks becomes computationally more challenging, as most meaningful assumptions instantly lead to NP-hard problems. Most previous algorithmic work on network alignments is heuristic in nature. Results We introduce the graph-based maximum structural matching formulation for pairwise global network alignment. We relate the formulation to previous work and prove NP-hardness of the problem. Based on the new formulation we build upon recent results in computational structural biology and present a novel Lagrangian relaxation approach that, in combination with a branch-and-bound method, computes provably optimal network alignments. The Lagrangian algorithm alone is a powerful heuristic method, which produces solutions that are often near-optimal and – unlike those computed by pure heuristics – come with a quality guarantee. Conclusion Computational experiments on the alignment of protein-protein interaction networks and on the classification of metabolic subnetworks demonstrate that the new method is reasonably fast and has advantages over pure heuristics. Our software tool is freely available as part of the LISA library. PMID:19208162

  2. Aligning Biomolecular Networks Using Modular Graph Kernels

    NASA Astrophysics Data System (ADS)

    Towfic, Fadi; Greenlee, M. Heather West; Honavar, Vasant

    Comparative analysis of biomolecular networks constructed using measurements from different conditions, tissues, and organisms offer a powerful approach to understanding the structure, function, dynamics, and evolution of complex biological systems. We explore a class of algorithms for aligning large biomolecular networks by breaking down such networks into subgraphs and computing the alignment of the networks based on the alignment of their subgraphs. The resulting subnetworks are compared using graph kernels as scoring functions. We provide implementations of the resulting algorithms as part of BiNA, an open source biomolecular network alignment toolkit. Our experiments using Drosophila melanogaster, Saccharomyces cerevisiae, Mus musculus and Homo sapiens protein-protein interaction networks extracted from the DIP repository of protein-protein interaction data demonstrate that the performance of the proposed algorithms (as measured by % GO term enrichment of subnetworks identified by the alignment) is competitive with some of the state-of-the-art algorithms for pair-wise alignment of large protein-protein interaction networks. Our results also show that the inter-species similarity scores computed based on graph kernels can be used to cluster the species into a species tree that is consistent with the known phylogenetic relationships among the species.

  3. A quick and reliable procedure for assessing foot alignment in athletes.

    PubMed

    De Michelis Mendonça, Luciana; Bittencourt, Natália Franco Netto; Amaral, Giovanna Mendes; Diniz, Lívia Santos; Souza, Thales Rezende; da Fonseca, Sérgio Teixeira

    2013-01-01

    Quick procedures with proper psychometric properties that can capture the combined alignment of the foot-ankle complex in a position that may be more representative of the status of the lower limb during ground contact are essential for assessing a large group of athletes. The assessed lower limb was positioned with the calcaneus surface facing upward in a way that all of the marks could be seen at the center of the camera display. After guaranteeing maintenance of the foot at 90° of dorsiflexion actively sustained by the athlete, the examiner took the picture of the foot-ankle alignment. Intraclass correlation coefficients ranging from 0.82 to 0.93 demonstrated excellent intratester and intertester reliability for the proposed measurements of forefoot, rearfoot, and shank-forefoot alignments. The intraclass correlation coefficient between the shank-forefoot measures and the sum of the rearfoot and forefoot measures was 0.98, suggesting that the shank-forefoot alignment measures can represent the combined rearfoot and forefoot alignments. This study describes a reliable and practical measurement procedure for rearfoot, forefoot, and shank-forefoot alignments that can be applied to clinical and research situations as a screening procedure for risk factors for lower-limb injuries in athletes.

  4. Scanning wave photopolymerization enables dye-free alignment patterning of liquid crystals

    PubMed Central

    Hisano, Kyohei; Aizawa, Miho; Ishizu, Masaki; Kurata, Yosuke; Nakano, Wataru; Akamatsu, Norihisa; Barrett, Christopher J.; Shishido, Atsushi

    2017-01-01

    Hierarchical control of two-dimensional (2D) molecular alignment patterns over large areas is essential for designing high-functional organic materials and devices. However, even by the most powerful current methods, dye molecules that discolor and destabilize the materials need to be doped in, complicating the process. We present a dye-free alignment patterning technique, based on a scanning wave photopolymerization (SWaP) concept, that achieves a spatial light–triggered mass flow to direct molecular order using scanning light to propagate the wavefront. This enables one to generate macroscopic, arbitrary 2D alignment patterns in a wide variety of optically transparent polymer films from various polymerizable mesogens with sufficiently high birefringence (>0.1) merely by single-step photopolymerization, without alignment layers or polarized light sources. A set of 150,000 arrays of a radial alignment pattern with a size of 27.4 μm × 27.4 μm were successfully inscribed by SWaP, in which each individual pattern is smaller by a factor of 104 than that achievable by conventional photoalignment methods. This dye-free inscription of microscopic, complex alignment patterns over large areas provides a new pathway for designing higher-performance optical and mechanical devices. PMID:29152567

  5. Quantification of Cardiomyocyte Alignment from Three-Dimensional (3D) Confocal Microscopy of Engineered Tissue.

    PubMed

    Kowalski, William J; Yuan, Fangping; Nakane, Takeichiro; Masumoto, Hidetoshi; Dwenger, Marc; Ye, Fei; Tinney, Joseph P; Keller, Bradley B

    2017-08-01

    Biological tissues have complex, three-dimensional (3D) organizations of cells and matrix factors that provide the architecture necessary to meet morphogenic and functional demands. Disordered cell alignment is associated with congenital heart disease, cardiomyopathy, and neurodegenerative diseases and repairing or replacing these tissues using engineered constructs may improve regenerative capacity. However, optimizing cell alignment within engineered tissues requires quantitative 3D data on cell orientations and both efficient and validated processing algorithms. We developed an automated method to measure local 3D orientations based on structure tensor analysis and incorporated an adaptive subregion size to account for multiple scales. Our method calculates the statistical concentration parameter, κ, to quantify alignment, as well as the traditional orientational order parameter. We validated our method using synthetic images and accurately measured principal axis and concentration. We then applied our method to confocal stacks of cleared, whole-mount engineered cardiac tissues generated from human-induced pluripotent stem cells or embryonic chick cardiac cells and quantified cardiomyocyte alignment. We found significant differences in alignment based on cellular composition and tissue geometry. These results from our synthetic images and confocal data demonstrate the efficiency and accuracy of our method to measure alignment in 3D tissues.

  6. Genetics Home Reference: Sheldon-Hall syndrome

    MedlinePlus

    ... proteins that are involved in muscle tensing (contraction). Muscle contraction occurs when thick filaments made of proteins called ... early development of the muscles. The process of muscle contraction is controlled (regulated) by other proteins called troponins ...

  7. Parallel seed-based approach to multiple protein structure similarities detection

    DOE PAGES

    Chapuis, Guillaume; Le Boudic-Jamin, Mathilde; Andonov, Rumen; ...

    2015-01-01

    Finding similarities between protein structures is a crucial task in molecular biology. Most of the existing tools require proteins to be aligned in order-preserving way and only find single alignments even when multiple similar regions exist. We propose a new seed-based approach that discovers multiple pairs of similar regions. Its computational complexity is polynomial and it comes with a quality guarantee—the returned alignments have both root mean squared deviations (coordinate-based as well as internal-distances based) lower than a given threshold, if such exist. We do not require the alignments to be order preserving (i.e., we consider nonsequential alignments), which makesmore » our algorithm suitable for detecting similar domains when comparing multidomain proteins as well as to detect structural repetitions within a single protein. Because the search space for nonsequential alignments is much larger than for sequential ones, the computational burden is addressed by extensive use of parallel computing techniques: a coarse-grain level parallelism making use of available CPU cores for computation and a fine-grain level parallelism exploiting bit-level concurrency as well as vector instructions.« less

  8. Algorithms for Automatic Alignment of Arrays

    NASA Technical Reports Server (NTRS)

    Chatterjee, Siddhartha; Gilbert, John R.; Oliker, Leonid; Schreiber, Robert; Sheffler, Thomas J.

    1996-01-01

    Aggregate data objects (such as arrays) are distributed across the processor memories when compiling a data-parallel language for a distributed-memory machine. The mapping determines the amount of communication needed to bring operands of parallel operations into alignment with each other. A common approach is to break the mapping into two stages: an alignment that maps all the objects to an abstract template, followed by a distribution that maps the template to the processors. This paper describes algorithms for solving the various facets of the alignment problem: axis and stride alignment, static and mobile offset alignment, and replication labeling. We show that optimal axis and stride alignment is NP-complete for general program graphs, and give a heuristic method that can explore the space of possible solutions in a number of ways. We show that some of these strategies can give better solutions than a simple greedy approach proposed earlier. We also show how local graph contractions can reduce the size of the problem significantly without changing the best solution. This allows more complex and effective heuristics to be used. We show how to model the static offset alignment problem using linear programming, and we show that loop-dependent mobile offset alignment is sometimes necessary for optimum performance. We describe an algorithm with for determining mobile alignments for objects within do loops. We also identify situations in which replicated alignment is either required by the program itself or can be used to improve performance. We describe an algorithm based on network flow that replicates objects so as to minimize the total amount of broadcast communication in replication.

  9. Quantum communication complexity of establishing a shared reference frame.

    PubMed

    Rudolph, Terry; Grover, Lov

    2003-11-21

    We discuss the aligning of spatial reference frames from a quantum communication complexity perspective. This enables us to analyze multiple rounds of communication and give several simple examples demonstrating tradeoffs between the number of rounds and the type of communication. Using a distributed variant of a quantum computational algorithm, we give an explicit protocol for aligning spatial axes via the exchange of spin-1/2 particles which makes no use of either exchanged entangled states, or of joint measurements. This protocol achieves a worst-case fidelity for the problem of "direction finding" that is asymptotically equivalent to the optimal average case fidelity achievable via a single forward communication of entangled states.

  10. Cholesterol-diethylenetriaminepentaacetate complexed with thulium ions integrated into bicelles to increase their magnetic alignability.

    PubMed

    Liebi, Marianne; Kuster, Simon; Kohlbrecher, Joachim; Ishikawa, Takashi; Fischer, Peter; Walde, Peter; Windhab, Erich J

    2013-11-27

    Lanthanides have been used for several decades to increase the magnetic alignability of bicelles. DMPE-DTPA (1,2-dimyristoyl-sn-glycero-3-phospho-ethanolamine-diethylenetriaminepentaacetate) is commonly applied to anchor the lanthanides into the bicelles. However, because DMPE-DTPA has the tendency to accumulate at the highly curved edge region of the bicelles and if located there does not contribute to the magnetic orientation energy, we have tested cholesterol-DTPA complexed with thulium ions (Tm(3+)) as an alternative chelator to increase the magnetic alignability. Differential scanning calorimetric (DSC) measurements indicate the successful integration of cholesterol-DTPA into a DMPC (1,2-dimyristoyl-sn-glycero-3-phosphocholine) bilayer. Cryo transmission electron microscopy and small-angle neutron scattering (SANS) measurements show that the disklike structure, that is, bicelles, is maintained if cholesterol-DTPA·Tm(3+) is integrated into a mixture of DMPC, cholesterol, and DMPE-DTPA·Tm(3+). The size of the bicelles is increased compared to the size of the bicelles obtained from mixtures without cholesterol-DTPA·Tm(3+). Magnetic-field-induced birefringence and SANS measurements in a magnetic field show that with addition of cholesterol-DTPA·Tm(3+) the magnetic alignability of these bicelles is significantly increased compared to bicelles composed of DMPC, cholesterol, and DMPE-DTPA·Tm(3+) only.

  11. Three-dimensional matrix fiber alignment modulates cell migration and MT1-MMP utility by spatially and temporally directing protrusions

    NASA Astrophysics Data System (ADS)

    Fraley, Stephanie I.; Wu, Pei-Hsun; He, Lijuan; Feng, Yunfeng; Krisnamurthy, Ranjini; Longmore, Gregory D.; Wirtz, Denis

    2015-10-01

    Multiple attributes of the three-dimensional (3D) extracellular matrix (ECM) have been independently implicated as regulators of cell motility, including pore size, crosslink density, structural organization, and stiffness. However, these parameters cannot be independently varied within a complex 3D ECM protein network. We present an integrated, quantitative study of these parameters across a broad range of complex matrix configurations using self-assembling 3D collagen and show how each parameter relates to the others and to cell motility. Increasing collagen density resulted in a decrease and then an increase in both pore size and fiber alignment, which both correlated significantly with cell motility but not bulk matrix stiffness within the range tested. However, using the crosslinking enzyme Transglutaminase II to alter microstructure independently of density revealed that motility is most significantly predicted by fiber alignment. Cellular protrusion rate, protrusion orientation, speed of migration, and invasion distance showed coupled biphasic responses to increasing collagen density not predicted by 2D models or by stiffness, but instead by fiber alignment. The requirement of matrix metalloproteinase (MMP) activity was also observed to depend on microstructure, and a threshold of MMP utility was identified. Our results suggest that fiber topography guides protrusions and thereby MMP activity and motility.

  12. Optimal and fast rotational alignment of volumes with missing data in Fourier space.

    PubMed

    Shatsky, Maxim; Arbelaez, Pablo; Glaeser, Robert M; Brenner, Steven E

    2013-11-01

    Electron tomography of intact cells has the potential to reveal the entire cellular content at a resolution corresponding to individual macromolecular complexes. Characterization of macromolecular complexes in tomograms is nevertheless an extremely challenging task due to the high level of noise, and due to the limited tilt angle that results in missing data in Fourier space. By identifying particles of the same type and averaging their 3D volumes, it is possible to obtain a structure at a more useful resolution for biological interpretation. Currently, classification and averaging of sub-tomograms is limited by the speed of computational methods that optimize alignment between two sub-tomographic volumes. The alignment optimization is hampered by the fact that the missing data in Fourier space has to be taken into account during the rotational search. A similar problem appears in single particle electron microscopy where the random conical tilt procedure may require averaging of volumes with a missing cone in Fourier space. We present a fast implementation of a method guaranteed to find an optimal rotational alignment that maximizes the constrained cross-correlation function (cCCF) computed over the actual overlap of data in Fourier space. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Strain-induced alignment and phase behavior of blue phase liquid crystals confined to thin films.

    PubMed

    Bukusoglu, Emre; Martinez-Gonzalez, Jose A; Wang, Xiaoguang; Zhou, Ye; de Pablo, Juan J; Abbott, Nicholas L

    2017-12-06

    We report on the influence of surface confinement on the phase behavior and strain-induced alignment of thin films of blue phase liquid crystals (BPs). Confining surfaces comprised of bare glass, dimethyloctadecyl [3-(trimethoxysilyl)propyl] ammonium chloride (DMOAP)-functionalized glass, or polyvinyl alcohol (PVA)-coated glass were used with or without mechanically rubbing to influence the azimuthal anchoring of the BPs. These experiments reveal that confinement can change the phase behavior of the BP films. For example, in experiments performed with rubbed-PVA surfaces, we measured the elastic strain of the BPs to change the isotropic-BPII phase boundary, suppressing formation of BPII for film thicknesses incommensurate with the BPII lattice. In addition, we observed strain-induced alignment of the BPs to exhibit a complex dependence on both the surface chemistry and azimuthal alignment of the BPs. For example, when using bare glass surfaces causing azimuthally degenerate and planar anchoring, BPI oriented with (110) planes of the unit cell parallel to the contacting surfaces for thicknesses below 3 μm but transitioned to an orientation with (200) planes aligned parallel to the contacting surfaces for thicknesses above 4 μm. In contrast, BPI aligned with (110) planes parallel to confining surfaces for all other thicknesses and surface treatments, including bare glass with uniform azimuthal alignment. Complementary simulations based on minimization of the total free energy (Landau-de Gennes formalism) confirmed a thickness-dependent reorientation due to strain of BPI unit cells within a window of surface anchoring energies and in the absence of uniform azimuthal alignment. In contrast to BPI, BPII did not exhibit thickness-dependent orientations but did exhibit orientations that were dependent on the surface chemistry, a result that was also captured in simulations by varying the anchoring energies. Overall, the results in this paper reveal that the orientations assumed by BPs in thin films reflect a complex interplay of surface interactions and elastic energies associated with strain of the BP lattice. The results also provide new principles and methods to control the structure and properties of BP thin films, which may find use in BP-templated material synthesis, and BP-based optical and electronic devices.

  14. The RAPID-CTCA trial (Rapid Assessment of Potential Ischaemic Heart Disease with CTCA) - a multicentre parallel-group randomised trial to compare early computerised tomography coronary angiography versus standard care in patients presenting with suspected or confirmed acute coronary syndrome: study protocol for a randomised controlled trial.

    PubMed

    Gray, Alasdair J; Roobottom, Carl; Smith, Jason E; Goodacre, Steve; Oatey, Katherine; O'Brien, Rachel; Storey, Robert F; Na, Lumine; Lewis, Steff C; Thokala, Praveen; Newby, David E

    2016-12-07

    Emergency department attendances with chest pain requiring assessment for acute coronary syndrome (ACS) are a major global health issue. Standard assessment includes history, examination, electrocardiogram (ECG) and serial troponin testing. Computerised tomography coronary angiography (CTCA) enables additional anatomical assessment of patients for coronary artery disease (CAD) but has only been studied in very low-risk patients. This trial aims to investigate the effect of early CTCA upon interventions, event rates and health care costs in patients with suspected/confirmed ACS who are at intermediate risk. Participants will be recruited in about 35 tertiary and district general hospitals in the UK. Patients ≥18 years old with symptoms with suspected/confirmed ACS with at least one of the following will be included: (1) ECG abnormalities, e.g. ST-segment depression >0.5 mm; (2) history of ischaemic heart disease; (3) troponin elevation above the 99 th centile of the normal reference range or increase in high-sensitivity troponin meeting European Society of Cardiology criteria for 'rule-in' of myocardial infarction (MI). The early use of ≥64-slice CTCA as part of routine assessment will be compared to standard care. The primary endpoint will be 1-year all-cause death or recurrent type 1 or type 4b MI at 1 year, measured as the time to such event. A number of secondary clinical, process and safety endpoints will be collected and analysed. Cost effectiveness will be estimated in terms of the lifetime incremental cost per quality-adjusted life year gained. We plan to recruit 2424 (2500 with ~3% drop-out) evaluable patients (1212 per arm) to have 90% power to detect a 20% versus 15% difference in 1-year death or recurrent type 1 MI or type 4b MI, two-sided p < 0.05. Analysis will be on an intention-to-treat basis. The relationship between intervention and the primary outcome will be analysed using Cox proportional hazard regression adjusted for study site (used to stratify the randomisation), age, baseline Global Registry of Acute Coronary Events score, previous CAD and baseline troponin level. The results will be expressed as a hazard ratio with the corresponding 95% confidence intervals and p value. The Rapid Assessment of Potential Ischaemic Heart Disease with CTCA (RAPID-CTCA) trial will recruit 2500 participants across about 35 hospital sites. It will be the first study to investigate the role of CTCA in the early assessment of patients with suspected or confirmed ACS who are at intermediate risk and including patients who have raised troponin measurements during initial assessment. ISRCTN19102565 . Registered on 3 October 2014. ClinicalTrials.gov: NCT02284191.

  15. Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A

    2013-04-26

    Alignment is important for comfortable and stable gait of lower-limb prosthesis users. The magnitude of socket reaction moments in the multiple planes acting simultaneously upon the residual limb may be related to perception of comfort in individuals using prostheses through socket interface pressures. The aim of this study was to investigate the effect of prosthetic alignment changes on sagittal and coronal socket reaction moment interactions (moment-moment curves) and to characterize the curves in 11 individuals with transtibial amputation using novel moment-moment interaction parameters measured by plotting sagittal socket reaction moments versus coronal ones under various alignment conditions. A custom instrumented prosthesis alignment component was used to measure socket reaction moments during walking. Prosthetic alignment was tuned to a nominally aligned condition by a prosthetist, and from this position, angular (3° and 6° of flexion, extension, abduction or adduction of the socket) and translational (5mm and 10mm of anterior, posterior, medial or lateral translation of the socket) alignment changes were performed in either the sagittal or the coronal plane in a randomized manner. A total of 17 alignment conditions were tested. Coronal angulation and translation alignment changes demonstrated similar consistent changes in the moment-moment curves. Sagittal alignment changes demonstrated more complex changes compared to the coronal alignment changes. Effect of sagittal angulations and translations on the moment-moment curves was different during 2nd rocker (mid-stance) with extension malalignment appearing to cause medio-lateral instability. Presentation of coronal and sagittal socket reaction moment interactions may provide useful visual information for prosthetists to understand the biomechanical effects of malalignment of transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Pairwise alignment of chromatograms using an extended Fisher-Rao metric.

    PubMed

    Wallace, W E; Srivastava, A; Telu, K H; Simón-Manso, Y

    2014-09-02

    A conceptually new approach for aligning chromatograms is introduced and applied to examples of metabolite identification in human blood plasma by liquid chromatography-mass spectrometry (LC-MS). A square-root representation of the chromatogram's derivative coupled with an extended Fisher-Rao metric enables the computation of relative differences between chromatograms. Minimization of these differences using a common dynamic programming algorithm brings the chromatograms into alignment. Application to a complex sample, National Institute of Standards and Technology (NIST) Standard Reference Material 1950, Metabolites in Human Plasma, analyzed by two different LC-MS methods having significantly different ranges of elution time is described. Published by Elsevier B.V.

  17. Blood test could predict risk of heart attack and subsequent death.

    PubMed

    2017-01-18

    A high-sensitivity blood test, known as a troponin test, could predict the risk of heart attack and death and patients' response to statins, say researchers from the Universities of Edinburgh and Glasgow.

  18. Clinical and electrocardiographic presentations of transient trifascicular block in three cats.

    PubMed

    Oxford, Eva M; Giacomazzi, Flavia B; Moïse, N Sydney; Santilli, Roberto A

    2018-06-01

    This report describes transient trifascicular block in three cats presented with lethargy and inappetence, and elevated cardiac troponin I concentrations. The electrocardiogram (ECG) of cat 1 showed a sinus rhythm with pronounced first-degree atrioventricular (AV) block, right bundle branch block, and left anterior fascicular block. The ECG of cat 2 showed truncular left bundle branch block alternating with left anterior fascicular block coupled with prolonged PR intervals, second-degree heart block, and paroxysmal third-degree AV block. The ECG of cat 3 showed first-degree AV block with concomitant right bundle branch block. The diagnosis of trifascicular block was made when paroxysmal third-degree AV block was documented. All cats recovered with medical management within weeks. Each cat resumed a sinus rhythm. Elevated cardiac troponin I concentrations suggested myocarditis that improved. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Oxidative stress and cardiomyocyte necrosis with elevated serum troponins: pathophysiologic mechanisms.

    PubMed

    Robinson, Antwon D; Ramanathan, Kodangudi B; McGee, Jesse E; Newman, Kevin P; Weber, Karl T

    2011-08-01

    The progressive nature of heart failure is linked to multiple factors, including an ongoing loss of cardiomyocytes and necrosis. Necrotic cardiomyocytes leave behind several footprints: the spillage of their contents leading to elevations in serum troponins; and morphologic evidence of tissue repair with scarring. The pathophysiologic origins of cardiomyocyte necrosis relates to neurohormonal activation, including the adrenergic nervous system. Catecholamine-initiated excessive intracellular Ca accumulation and mitochondria Ca overloading in particular initiate a mitochondriocentric signal-transducer-effector pathway to necrosis and which includes the induction of oxidative stress and opening of their inner membrane permeability transition pore. Hypokalemia, ionized hypocalcemia and hypomagnesemia, where consequent elevations in parathyroid hormone further account for excessive intracellular Ca accumulation, hypozincemia and hyposelenemia each compromise metalloenzyme-based antioxidant defenses. The necrotic loss of cardiomyocytes and adverse structural remodeling of myocardium is related to the central role played by a mitochondriocentric pathway initiated by neurohormonal activation.

  20. A novel perfused rotary bioreactor for cardiomyogenesis of embryonic stem cells.

    PubMed

    Teo, Ailing; Mantalaris, Athanasios; Song, Kedong; Lim, Mayasari

    2014-05-01

    Developments in bioprocessing technology play an important role for overcoming challenges in cardiac tissue engineering. To this end, our laboratory has developed a novel rotary perfused bioreactor for supporting three-dimensional cardiac tissue engineering. The dynamic culture environments provided by our novel perfused rotary bioreactor and/or the high-aspect rotating vessel produced constructs with higher viability and significantly higher cell numbers (up to 4 × 10(5) cells/bead) than static tissue culture flasks. Furthermore, cells in the perfused rotary bioreactor showed earlier gene expressions of cardiac troponin-T, α- and β-myosin heavy chains with higher percentages of cardiac troponin-I-positive cells and better uniformity of sacromeric α-actinin expression. A dynamic and perfused environment, as provided by this bioreactor, provides a superior culture performance in cardiac differentiation for embryonic stem cells particularly for larger 3D constructs.

  1. Juvenile Churg-Strauss Syndrome as an Etiology of Myocarditis and Ischemic Stroke in Adolescents; a Case Report

    PubMed Central

    Moradinejad, Mohammad-Hassan; Rezaei, Amir; Ziaee, Vahid

    2011-01-01

    Background Churg-Strauss syndrome (CSS), a systemic vasculitis accompanied by asthma and eosinophilia, almost invariably affects the lung and is frequently associated with cutaneous involvement. It rarely has cardiac involvement. We report an unusual case of CSS with myocardial involvement and stroke. Case Presentation A 16-year old female suffered of allergic asthma for 4 years. She was under treatment with oral prednisolone and seretide inhalation. After CSS diagnosis, she developed paroxysmal atrial tachycardia. Serum levels of Troponin I and Troponin T were increased indicating massive myocardial damage probably due to myocarditis. After 5 months she developed acute hemiparesis without any evidence of ischemic or hemorrhagic event. She was treated with IVIg, intravenous pulses of methylprednisone and cyclophosphamide for each complication. Conclusion Myocarditis and stroke may also complicate CSS which should be taken in consideration for better management. PMID:23056844

  2. Giant cell myositis responsive to combined corticosteroids and immunoglobulin.

    PubMed

    Shah, A; Pace, A; Hilton, D; Househam, E; Weatherby, S

    2015-12-01

    A 70-year-old man presented with respiratory distress and proximal muscle weakness shortly after biopsy of a left forearm mass. The biopsy showed giant cell myositis, and serological investigations identified a grossly elevated serum creatine kinase level, suggesting skeletal muscle damage. Serum troponin T was also high, but troponin I was normal. Serum antiacetylcholine receptor antibodies were positive, and imaging showed a thymoma. He recovered well following intravenous immunoglobulin and corticosteroids, and later underwent thymectomy. He is currently in sustained remission, with no clinically detectable myasthenia, but subsequently, developed hypogammaglobulinaemia. Neurologists should remember giant cell myositis/myocarditis can occur in patients who have myasthenia gravis with thymoma, as it is potentially fatal, but may respond to immunosuppression. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Use of Cardiac Injury Markers in the Postmortem Diagnosis of Sudden Cardiac Death.

    PubMed

    Carvajal-Zarrabal, Octavio; Hayward-Jones, Patricia M; Nolasco-Hipolito, Cirilo; Barradas-Dermitz, Dulce Ma; Calderón-Garcidueñas, Ana Laura; López-Amador, Noé

    2017-09-01

    In the daily practice of forensic pathology, sudden cardiac death (SCD) is a diagnostic challenge. Our aim was to determine the usefulness of blood biomarkers [creatine kinase CK-MB, myoglobin, troponins I and T (cTn-I and T), and lactate dehydrogenase] measured by immunoassay technique, in the postmortem diagnosis of SCD. Two groups were compared, 20 corpses with SCD and 8 controls. Statistical significance was determined by variance analysis procedures, with a post hoc Tukey multiple range test for comparison of means (p < 0.05). SCD cases showed significantly higher levels (p < 0.05) of cTn-T and cTn-I compared to the control group. Although only cases within the first 8 h of postmortem interval were included, and the control group consisted mainly of violent death cases, our results suggest that blood troponin levels may be useful to support a diagnosis of SCD. © 2017 American Academy of Forensic Sciences.

  4. A Case Report of Salmonella muenchen Enteritis Causing Rhabdomyolysis and Myocarditis in a Previously Healthy 26-Year-Old Man.

    PubMed

    Chapple, Will; Martell, Jon; Wilson, Joy S; Matsuura, Don T

    2017-04-01

    This case report examines an unusual presentation of a non-typhoidal Salmonella serovar with limited prevalence in the literature. This is the first case report to associate specifically the Salmonella muenchen serovar with rhabdomyolysis and myocarditis. This case report reviews the diagnostic criteria for myocarditis and explores the diagnostic dilemma of troponin elevation in the setting of rhabdomyolysis. It demonstrates that Salmonella muenchen has the ability to present in a broad range of individuals with complications extending beyond classical gastrointestinal symptoms. This report also concludes that diagnosis of the many possible complications from non-typhoidal Salmonella infections can be difficult due to patient comorbidities, variability in the severity of the illnesses, laboratory test limitations, and imaging limitations. When a patient presents with elevated troponins in the setting of rhabdomyolysis a careful workup should be done to evaluate for ischemic causes, myocarditis, or false elevation secondary to rhabdomyolysis.

  5. Evaluation of a new ultrasensitive assay for cardiac troponin I.

    PubMed

    Casals, Gregori; Filella, Xavier; Bedini, Josep Lluis

    2007-12-01

    We evaluated the analytical and clinical performance of a new ultrasensitive cardiac troponin I assay (cTnI) on the ADVIA Centaur system (TnI-Ultra). The evaluation included the determination of detection limit, within-assay and between-assay variation and comparison with two other non-ultrasensitive methods. Moreover, cTnI was determined in 120 patients with acute chest pain with three methods. To evaluate the ability of the new method to detect MI earlier, it was assayed in 8 MI patients who first tested negative then positive by the other methods. The detection limit was 0.009 microg/L and imprecision was <10% at all concentrations evaluated. In comparison with two other methods, 10% of the anginas diagnosed were recategorized to MI. The ADVIA Centaur TnI-Ultra assay presented high reproducibility and high sensitivity. The use of the recommended lower cutpoint (0.044 microg/L) implied an increased and earlier identification of MI.

  6. Megaliths and Neolithic astronomy in southern Egypt

    NASA Astrophysics Data System (ADS)

    Malville, J. Mckim; Wendorf, Fred; Mazar, Ali A.; Schild, Romauld

    1998-04-01

    The Sahara west of the Nile in southern Egypt was hyperarid and unoccupied during most of the Late Pleistocene epoch. About 11,000 years ago the summer monsoons of central Africa moved into Egypt, and temporary lakes or playas were formed. The Nabta Playa depression, which is one of the largest in southern Egypt, is a kidney-shaped basin of roughly 10km by 7km in area. We report the discovery of megalithic alignments and stone circles next to locations of Middle and Late Neolithic communities at Nabta, which suggest the early development of a complex society. The southward shift of the monsoons in the Late Neolithic age rendered the area once again hyperarid and uninhabitable some 4,800 radiocarbon years before the present (years BP). This well-determined date establishes that the ceremonial complex of Nabta, which has alignments to cardinal and solstitial directions, was a very early megalithic expression of ideology and astronomy. Five megalithic alignments within the playa deposits radiate outwards from megalithic structures, which may have been funerary structures. The organization of the megaliths suggests a symbolic geometry that integrated death, water, and the Sun. An exodus from the Nubian Desert at ~4,800 years BP may have stimulated social differentiation and cultural complexity in predynastic Upper Egypt.

  7. Argument Structure of Tsou: Simplex and Complex Predicates

    ERIC Educational Resources Information Center

    Lin, Gujing

    2010-01-01

    This thesis investigates the argument structure of Tsou, a Formosan language within the Austronesian family. The investigation studies both simplex and complex predicates as well as describes the valency groupings and alignment patterns emerging from various clausal configurations. Assuming the stance that language description should respect…

  8. A Lossy Compression Technique Enabling Duplication-Aware Sequence Alignment

    PubMed Central

    Freschi, Valerio; Bogliolo, Alessandro

    2012-01-01

    In spite of the recognized importance of tandem duplications in genome evolution, commonly adopted sequence comparison algorithms do not take into account complex mutation events involving more than one residue at the time, since they are not compliant with the underlying assumption of statistical independence of adjacent residues. As a consequence, the presence of tandem repeats in sequences under comparison may impair the biological significance of the resulting alignment. Although solutions have been proposed, repeat-aware sequence alignment is still considered to be an open problem and new efficient and effective methods have been advocated. The present paper describes an alternative lossy compression scheme for genomic sequences which iteratively collapses repeats of increasing length. The resulting approximate representations do not contain tandem duplications, while retaining enough information for making their comparison even more significant than the edit distance between the original sequences. This allows us to exploit traditional alignment algorithms directly on the compressed sequences. Results confirm the validity of the proposed approach for the problem of duplication-aware sequence alignment. PMID:22518086

  9. Introducing Evidence Through Research "Push": Using Theory and Qualitative Methods.

    PubMed

    Morden, Andrew; Ong, Bie Nio; Brooks, Lauren; Jinks, Clare; Porcheret, Mark; Edwards, John J; Dziedzic, Krysia S

    2015-11-01

    A multitude of factors can influence the uptake and implementation of complex interventions in health care. A plethora of theories and frameworks recognize the need to establish relationships, understand organizational dynamics, address context and contingency, and engage key decision makers. Less attention is paid to how theories that emphasize relational contexts can actually be deployed to guide the implementation of an intervention. The purpose of the article is to demonstrate the potential role of qualitative research aligned with theory to inform complex interventions. We detail a study underpinned by theory and qualitative research that (a) ensured key actors made sense of the complex intervention at the earliest stage of adoption and (b) aided initial engagement with the intervention. We conclude that using theoretical approaches aligned with qualitative research can provide insights into the context and dynamics of health care settings that in turn can be used to aid intervention implementation. © The Author(s) 2015.

  10. Whole-genome alignment.

    PubMed

    Dewey, Colin N

    2012-01-01

    Whole-genome alignment (WGA) is the prediction of evolutionary relationships at the nucleotide level between two or more genomes. It combines aspects of both colinear sequence alignment and gene orthology prediction, and is typically more challenging to address than either of these tasks due to the size and complexity of whole genomes. Despite the difficulty of this problem, numerous methods have been developed for its solution because WGAs are valuable for genome-wide analyses, such as phylogenetic inference, genome annotation, and function prediction. In this chapter, we discuss the meaning and significance of WGA and present an overview of the methods that address it. We also examine the problem of evaluating whole-genome aligners and offer a set of methodological challenges that need to be tackled in order to make the most effective use of our rapidly growing databases of whole genomes.

  11. Preoperative Statin Therapy in Cardiac Surgery Is More Effective in Patients Who Display Preoperative Activation of the Inflammatory System

    PubMed Central

    Martínez-Comendador, José; Alvarez, José Rubio; Sierra, Juan; Teijeira, Elvis; Adrio, Belén

    2013-01-01

    We sought to determine whether preoperative statin treatment is more effective in reducing, after cardiac surgery with cardiopulmonary bypass, systemic inflammatory response and myocardial damage markers in patients who have elevated preoperative interleukin-6 levels than in patients who have normal preoperative interleukin-6 levels. The study involved a prospective cohort of 164 patients who underwent coronary and valvular surgery with cardiopulmonary bypass. There were 2 study groups: group A (n = 60), patients with elevated preoperative interleukin-6 levels; and group B (n = 104), patients with normal preoperative interleukin-6 levels. Each group was subdivided according to whether patients were (group 1) or were not (group 2) treated preoperatively with statins. Accordingly, the subdivided study groups were A1 (n = 40), A2 (n = 20), B1 (n = 56), and B2 (n = 48). The plasma levels of proinflammatory interleukin-6 were measured 1, 6, 24, and >72 hours after surgery. The baseline, operative, and postoperative morbidity and mortality characteristics were similar in all groups. Group A1 had significantly lower levels of interleukin-6 and troponin I than did group A2 at all postoperative time points. Group B1 had significantly lower levels of interleukin-6 than did group B2 postoperatively. There were no significant differences in troponin I levels between groups B1 and B2. We conclude that, in patients with preoperative activation of the inflammatory system, preoperative treatment with statins is associated with lower postoperative interleukin-6 and troponin I levels after cardiac surgery with cardiopulmonary bypass. PMID:23466655

  12. Preoperative statin therapy in cardiac surgery is more effective in patients who display preoperative activation of the inflammatory system.

    PubMed

    Martínez-Comendador, José; Alvarez, José Rubio; Sierra, Juan; Teijeira, Elvis; Adrio, Belén

    2013-01-01

    We sought to determine whether preoperative statin treatment is more effective in reducing, after cardiac surgery with cardiopulmonary bypass, systemic inflammatory response and myocardial damage markers in patients who have elevated preoperative interleukin-6 levels than in patients who have normal preoperative interleukin-6 levels. The study involved a prospective cohort of 164 patients who underwent coronary and valvular surgery with cardiopulmonary bypass. There were 2 study groups: group A (n = 60), patients with elevated preoperative interleukin-6 levels; and group B (n = 104), patients with normal preoperative interleukin-6 levels. Each group was subdivided according to whether patients were (group 1) or were not (group 2) treated preoperatively with statins. Accordingly, the subdivided study groups were A1 (n = 40), A2 (n = 20), B1 (n = 56), and B2 (n = 48). The plasma levels of proinflammatory interleukin-6 were measured 1, 6, 24, and >72 hours after surgery. The baseline, operative, and postoperative morbidity and mortality characteristics were similar in all groups. Group A1 had significantly lower levels of interleukin-6 and troponin I than did group A2 at all postoperative time points. Group B1 had significantly lower levels of interleukin-6 than did group B2 postoperatively. There were no significant differences in troponin I levels between groups B1 and B2. We conclude that, in patients with preoperative activation of the inflammatory system, preoperative treatment with statins is associated with lower postoperative interleukin-6 and troponin I levels after cardiac surgery with cardiopulmonary bypass.

  13. [The association of eccentricity indexes with cardiac biomarkers in normotensive acute pulmonary embolism patients: an observational study].

    PubMed

    Cetiner, Mehmet Ali; Sayın, Muhammet Raşit; Yıldırım, Nesligül; Karabağ, Turgut; Aydın, Mustafa

    2013-03-01

    The present study aims at investigating the association of systolic and diastolic eccentricity indexes with cardiac biomarkers in hemodynamically stable patients with acute pulmonary embolism (APE). Thirty hemodynamically stable (systolic blood pressure >90 mmHg) patients with APE (17M, mean age 61.67±17.6 years) were included in this cross-sectional observational study. The associations of serum troponin I, D-dimer, brain natriuretic peptide (BNP) and heart type fatty acid binding protein (hFABP) levels with systolic and diastolic eccentricity indices, tricuspid annular plane systolic excursion (TAPSE), myocardial performance index (MPI), systolic pulmonary artery pressure and the index of the inferior vena cava were investigated. The relationships between parameters were evaluated by Pearson and Spearman correlation analysis according to the distribution of data. Correlation analysis revealed that the most significant relationship between cardiac biomarkers and echocardiographic measurements was in the BNP value. Meanwhile, systolic and diastolic eccentricity indexes were found to have significant correlation with serum troponin I (respectively r=0.470, p=0.009/r=0.310, p=0.095) and BNP (respectively r=0.402, p=0.028/r=0.384, p=0.036) values. On the other hand, elevated D-dimer levels led to statistical significance in none of the echocardiographic parameters. According to our results, hFABP was rarely positive in normotensive patients with APE. An elevated D-dimer alone was not significant in predicting RVD. Eccentricity indexes revealed significant relationship with BNP and troponin I values. The results obtained indicate that early echocardiographic evaluation is important in patients with abnormal cardiac biomarkers.

  14. Treatment of Non-ST Elevation Myocardial Infarction: A Process Analysis of Patient and Program Factors in a Teaching Hospital.

    PubMed

    Shepple, Benjamin I; Thistlethwaite, William A; Schumann, Christopher L; Akosah, Kwame O; Schutt, Robert C; Keeley, Ellen C

    2016-09-01

    As part of a quality improvement project, we performed a process analysis to evaluate how patients presenting with type 1 non-ST elevation myocardial infarction (STEMI) are diagnosed and managed early after the diagnosis has been made. We performed a retrospective chart review and collected detailed information regarding the timing of the first 12-lead electrocardiogram, troponin order entry and first positive troponin result, administration of anticoagulation and antiplatelet medications, and referral for coronary angiography to identify areas of treatment variability and delay. A total of 242 patients with type 1 non-STEMI were included. The majority of patients received aspirin early after presentation to the emergency department; however, there was significant variability in the time from presentation to administration of other medications, including anticoagulation and P2Y12 therapy, even after an elevated troponin level was documented in the chart. Lack of a standardized non-STEMI admission order set, inconsistency regarding whether the emergency department physician or the cardiology admitting team order these medications after the diagnosis is made, and per current protocol, the initial call regarding the patient made to the cardiology fellow, not the admitting house staff, were identified as possible contributors to the delay. Patients who presented during "nighttime" hours had higher rates of atypical symptoms (P = 0.036) and longer delays to coronary angiography (46.5 versus 24 hours, P < 0.001) even in those deemed intermediate to high risk. A process analysis revealed considerable variation in non-STEMI treatment in our teaching hospital and identified specific areas for quality improvement measures.

  15. Lack of concordance between a rapid bedside and conventional laboratory method of cardiac troponin testing: impact on risk stratification of patients suspected of acute coronary syndrome.

    PubMed

    Cramer, G Etienne; Kievit, Peter C; Brouwer, Marc A; de Keijzer, Marinus H; Luijten, Hans E; Verheugt, Freek W A

    2007-06-01

    This study was designed to test the usefulness of a bedside assay as compared to a laboratory method of troponin testing to predict adverse cardiac outcome of chest pain patients. We studied 358 ER visits of patients suspected of a non ST-elevation acute coronary syndrome. cTnI (Immulite, DPC) on a lab analyser and cTnT (Cardiac Reader, Roche) at bedside were measured at baseline. The between-assay level of concordance, reporting turnaround times and clinical outcomes during 180 days of follow-up were assessed. Death and myocardial infarction were then evaluated according to troponin result, either concordant negative, discordant or concordant positive. Discordance occurred in 11.4% (41/358) of cases. The proportion of patients with a positive cTnI and negative cTnT result (8.9%) versus the reverse (2.5%) differed significantly (p<0.001). The median time gained using the rapid test was 72 min. The rate of death and/or MI was 25% (10/40) among patients with discordant results as compared to 7.5% (17/228) with a concordant negative result (p<0.001). All patients from the discordant group with an event had a positive cTnI result, while cTnT was negative. Patients with a discordant reading were at high risk of adverse cardiac outcome, which was only identified by the laboratory cTnI assay. Markedly, the use of the rapid assay saved time at the expense of clinical sensitivity.

  16. A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform.

    PubMed

    Liu, Dongkui; Lu, Xing; Yang, Yiwen; Zhai, Yunyun; Zhang, Jian; Li, Lei

    2018-05-04

    Acute myocardial infarction (AMI) is one of the leading risks to global health. Thus, the rapid, accurate early diagnosis of AMI is highly critical. Human cardiac troponin I (cTnI) has been regarded as a golden biomarker for AMI due to its excellent selectivity. In this work, a novel fluorescent aptasensor based on a graphene oxide (GO) platform was developed for the highly sensitive and selective detection of cTnI. GO binds to the fluorescent anti-cTnI aptamer and quenches its fluorescence. In the presence of cTnI, the fluorescent anti-cTnI aptamer leaves the surface of GO, combines with cTnI because of the powerful affinity of the fluorescent anti-cTnI aptamer and cTnI, and then restores the fluorescence of the fluorescent anti-cTnI aptamer. Fluorescence-enhanced detection is highly sensitive and selective to cTnI. The method exhibited good analytical performance with a reasonable dynamic linearity at the concentration range of 0.10-6.0 ng/mL and a low detection limit of 0.07 ng/mL (S/N = 3). The fluorescent aptasensor also exhibited high selectivity toward cTnI compared with other interference proteins. The proposed method may be a potentially useful tool for cTnI determination in human serum. Graphical abstract A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform.

  17. Ca++-sensitizing mutations in troponin, Pi, and 2-deoxyATP alter the depressive effect of acidosis on regulated thin-filament velocity

    PubMed Central

    Longyear, Thomas J.; Turner, Matthew A.; Davis, Jonathan P.; Lopez, Joseph; Biesiadecki, Brandon

    2014-01-01

    Repeated, intense contractile activity compromises the ability of skeletal muscle to generate force and velocity, resulting in fatigue. The decrease in velocity is thought to be due, in part, to the intracellular build-up of acidosis inhibiting the function of the contractile proteins myosin and troponin; however, the underlying molecular basis of this process remains poorly understood. We sought to gain novel insight into the decrease in velocity by determining whether the depressive effect of acidosis could be altered by 1) introducing Ca++-sensitizing mutations into troponin (Tn) or 2) by agents that directly affect myosin function, including inorganic phosphate (Pi) and 2-deoxy-ATP (dATP) in an in vitro motility assay. Acidosis reduced regulated thin-filament velocity (VRTF) at both maximal and submaximal Ca++ levels in a pH-dependent manner. A truncated construct of the inhibitory subunit of Tn (TnI) and a Ca++-sensitizing mutation in the Ca++-binding subunit of Tn (TnC) increased VRTF at submaximal Ca++ under acidic conditions but had no effect on VRTF at maximal Ca++ levels. In contrast, both Pi and replacement of ATP with dATP reversed much of the acidosis-induced depression of VRTF at saturating Ca++. Interestingly, despite producing similar magnitude increases in VRTF, the combined effects of Pi and dATP were additive, suggesting different underlying mechanisms of action. These findings suggest that acidosis depresses velocity by slowing the detachment rate from actin but also by possibly slowing the attachment rate. PMID:24651988

  18. [Molecular modifications of troponin I and T detected in serum from patients with acute myocardial infarction].

    PubMed

    Atar, Dan; Madsen, Lene Helleskov; Labugger, Ralf; VanEyk, Jennifer E

    2003-01-06

    Cardiac troponin I and T (cTnI and cTnT) are specific biochemical serum markers for acute myocardial infarction (AMI). However, cTnI diagnostic assays are plagued by difficulties, resulting in > 20-fold differences in measured values. These discrepancies may result from the release of the numerous cTnI modification products that are present in ischaemic myocardium. The resolution of these discrepancies requires an investigation of the exact forms of the troponins present in the bloodstream of patients after myocardial injury. A Westernblot direct serum analysis protocol was developed that allowed us to detect intact cTnI and a spectrum of up to 11 modified products in the serum from patients with AMI. We document both a cTnI degradation pattern and the existence of phosphorylated cTnI in serum. The number and extent of these modifications reflect patterns similar to the time profiles of the routine clinical serum markers of total creatine kinase, creatine kinase-MB, and cTnI (determined by ELISA). Data from in vitro experiments, which were undertaken to study the degradation of human recombinant cTnI and cTnT when spiked in serum, indicate that some modification products present in patient serum existed in the myocardium. This pilot study defines, for the first time, what forms of cTnI and cTnT appear in the bloodstream of AMI patients, and it clarifies the lack of standardization between different cTnI diagnostic assays.

  19. The Novel Extracellular Cyclophilin A (CyPA) - Inhibitor MM284 Reduces Myocardial Inflammation and Remodeling in a Mouse Model of Troponin I -Induced Myocarditis.

    PubMed

    Heinzmann, David; Bangert, Anna; Müller, Anna-Maria; von Ungern-Sternberg, Saskia N I; Emschermann, Frederic; Schönberger, Tanja; Chatterjee, Madhumita; Mack, Andreas F; Klingel, Karin; Kandolf, Reinhard; Malesevic, Miroslav; Borst, Oliver; Gawaz, Meinrad; Langer, Harald F; Katus, Hugo; Fischer, Gunter; May, Andreas E; Kaya, Ziya; Seizer, Peter

    2015-01-01

    Cyclophilins are a group of highly conserved cytosolic enzymes that have a peptidylprolyl cis/trans isomerase activity. Cyclophilin A (CyPA) can be secreted in the extracellular space by inflammatory cells and upon cell death. The presence of CyPA in patients with non-ischemic cardiomyopathy is associated with poor clinical prognosis. Here, we investigated the inhibition of extracellular CyPA in a mouse model of troponin I-induced autoimmune myocarditis using the strictly extracellular CyPA-inhibitor MM284. Since A/J mice develop severe inflammation and fibrosis after immunization with murine cardiac troponin I (mcTn I), we used this model to analyze the effects of an extracellular CyPA inhibition. As extracellular CyPA-inhibitor we used the recently described CsA-derivate MM284. In vitro studies confirmed that MM284 inhibits CyPA-induced monocytic migration and adhesion. A/J mice immunized with mcTnI were treated with MM284 or vehicle every second day. After 28 days, we found a considerable reduction of myocardial injury and fibrosis. Further analysis revealed a reduced myocardial presence of T-cells and macrophages compared to control treated animals. Whereas MMP-9 expression was reduced significantly by MM284, we observed no significant reduction of inflammatory cytokines such as IL-6 or TNFα. Extracellular CyPA plays an important role in autoimmune myocarditis for myocardial damage and fibrosis. Our data suggest a new pharmacological approach for the treatment of myocardial inflammation and reduction of cardiac fibrosis by inhibition of extracellular CyPA.

  20. Sub-cell turning to accomplish micron-level alignment of precision assemblies

    NASA Astrophysics Data System (ADS)

    Kumler, James J.; Buss, Christian

    2017-08-01

    Higher performance expectations for complex optical systems demand tighter alignment requirements for lens assembly alignment. In order to meet diffraction limited imaging performance over wide spectral bands across the UV and visible wavebands, new manufacturing approaches and tools must be developed if the optical systems will be produced consistently in volume production. This is especially applicable in the field of precision microscope objectives for life science, semiconductor inspection and laser material processing systems. We observe a rising need for the improvement in the optical imaging performance of objective lenses. The key challenge lies in the micron-level decentration and tilt of each lens element. One solution for the production of high quality lens systems is sub-cell assembly with alignment turning. This process relies on an automatic alignment chuck to align the optical axis of a mounted lens to the spindle axis of the machine. Subsequently, the mount is cut with diamond tools on a lathe with respect to the optical axis of the mount. Software controlled integrated measurement technology ensures highest precision. In addition to traditional production processes, further dimensions can be controlled in a very precise manner, e.g. the air gaps between the lenses. Using alignment turning simplifies further alignment steps and reduces the risk of errors. This paper describes new challenges in microscope objective design and manufacturing, and addresses difficulties with standard production processes. A new measurement and alignment technique is described, and strengths and limitations are outlined.

  1. Cognitive and Affective Processes Underlying Career Change

    ERIC Educational Resources Information Center

    Muja, Naser; Appelbaum, Steven H.

    2012-01-01

    Purpose: Aligning social identity and career identity has become increasingly complex due to growth in the pursuit of meaningful careers that offer very long-term personal satisfaction and stability. This paper aims to explore the complex cognitive and affective thought process involved in the conscious planning of voluntary career change.…

  2. Flavivirus and Filovirus EvoPrinters: New alignment tools for the comparative analysis of viral evolution.

    PubMed

    Brody, Thomas; Yavatkar, Amarendra S; Park, Dong Sun; Kuzin, Alexander; Ross, Jermaine; Odenwald, Ward F

    2017-06-01

    Flavivirus and Filovirus infections are serious epidemic threats to human populations. Multi-genome comparative analysis of these evolving pathogens affords a view of their essential, conserved sequence elements as well as progressive evolutionary changes. While phylogenetic analysis has yielded important insights, the growing number of available genomic sequences makes comparisons between hundreds of viral strains challenging. We report here a new approach for the comparative analysis of these hemorrhagic fever viruses that can superimpose an unlimited number of one-on-one alignments to identify important features within genomes of interest. We have adapted EvoPrinter alignment algorithms for the rapid comparative analysis of Flavivirus or Filovirus sequences including Zika and Ebola strains. The user can input a full genome or partial viral sequence and then view either individual comparisons or generate color-coded readouts that superimpose hundreds of one-on-one alignments to identify unique or shared identity SNPs that reveal ancestral relationships between strains. The user can also opt to select a database genome in order to access a library of pre-aligned genomes of either 1,094 Flaviviruses or 460 Filoviruses for rapid comparative analysis with all database entries or a select subset. Using EvoPrinter search and alignment programs, we show the following: 1) superimposing alignment data from many related strains identifies lineage identity SNPs, which enable the assessment of sublineage complexity within viral outbreaks; 2) whole-genome SNP profile screens uncover novel Dengue2 and Zika recombinant strains and their parental lineages; 3) differential SNP profiling identifies host cell A-to-I hyper-editing within Ebola and Marburg viruses, and 4) hundreds of superimposed one-on-one Ebola genome alignments highlight ultra-conserved regulatory sequences, invariant amino acid codons and evolutionarily variable protein-encoding domains within a single genome. EvoPrinter allows for the assessment of lineage complexity within Flavivirus or Filovirus outbreaks, identification of recombinant strains, highlights sequences that have undergone host cell A-to-I editing, and identifies unique input and database SNPs within highly conserved sequences. EvoPrinter's ability to superimpose alignment data from hundreds of strains onto a single genome has allowed us to identify unique Zika virus sublineages that are currently spreading in South, Central and North America, the Caribbean, and in China. This new set of integrated alignment programs should serve as a useful addition to existing tools for the comparative analysis of these viruses.

  3. Early Invasive Versus Selective Strategy for Non-ST-Segment Elevation Acute Coronary Syndrome: The ICTUS Trial.

    PubMed

    Hoedemaker, Niels P G; Damman, Peter; Woudstra, Pier; Hirsch, Alexander; Windhausen, Fons; Tijssen, Jan G P; de Winter, Robbert J

    2017-04-18

    The ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes) trial compared early invasive strategy with a selective invasive strategy in patients with non-ST-segment elevation acute coronary syndrome (NSTE-ACS) and an elevated cardiac troponin T. No long-term benefit of an early invasive strategy was found at 1 and 5 years. The aim of this study was to determine the 10-year clinical outcomes of an early invasive strategy versus a selective invasive strategy in patients with NSTE-ACS and an elevated cardiac troponin T. The ICTUS trial was a multicenter, randomized controlled clinical trial that included 1,200 patients with NSTE-ACS and an elevated cardiac troponin T. Enrollment was from July 2001 to August 2003. We collected 10-year follow-up of death, myocardial infarction (MI), and revascularization through the Dutch population registry, patient phone calls, general practitioners, and hospital records. The primary outcome was the 10-year composite of death or spontaneous MI. Additional outcomes included the composite of death or MI, death, MI (spontaneous and procedure-related), and revascularization. Ten-year death or spontaneous MI was not statistically different between the 2 groups (33.8% vs. 29.0%, hazard ratio [HR]: 1.12; 95% confidence interval [CI]: 0.97 to 1.46; p = 0.11). Revascularization occurred in 82.6% of the early invasive group and 60.5% in the selective invasive group. There were no differences in additional outcomes, except for a higher rate of death or MI in the early invasive group compared with the rates for the selective invasive group (37.6% vs. 30.5%; HR: 1.30; 95% CI: 1.07 to 1.58; p = 0.009), driven by a higher rate of procedure-related MI in the early invasive group (6.5% vs. 2.4%; HR: 2.82; 95% CI: 1.53 to 5.20; p = 0.001). In patients with NSTE-ACS and elevated cardiac troponin T levels, an early invasive strategy has no benefit over a selective invasive strategy in reducing the 10-year composite outcome of death or spontaneous MI, and a selective invasive strategy may be a viable option in selected patients. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Analytical validation and establishment of reference intervals for a 'high-sensitivity' cardiac troponin-T assay in horses.

    PubMed

    Shields, E; Seiden-Long, I; Massie, S; Passante, S; Leguillette, R

    2016-06-13

    Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.

  5. Association of troponin T, detected with highly sensitive assay, and outcomes in infective endocarditis.

    PubMed

    Stancoven, Amy B; Shiue, Angela B; Khera, Amit; Pinkston, Kristi; Hashim, Ibrahim A; Wang, Andrew; de Lemos, James A; Peterson, Gail E

    2011-08-01

    Troponin levels have been correlated with adverse outcomes in multiple disease processes, including congestive heart failure, acute coronary syndromes, sepsis, and, in a few small series, infective endocarditis. We hypothesized that a novel measurement of troponin using a highly sensitive assay would correlate with adverse outcomes when prospectively studied in patients with infective endocarditis. At a single center in the International Collaboration on Endocarditis, 42 patients met the inclusion criteria and underwent testing for cardiac troponin T (cTnT) using both a standard and a highly sensitive precommercial assay. The cTnT levels were associated with the prespecified primary composite outcome of death, central nervous system event, and cardiac abscess. Secondary outcomes included the individual components of the composite outcome and the need for cardiac surgery. A receiver operating characteristic curve was derived and used to identify the optimal cutpoint for cTnT using the highly sensitive assay. cTnT was detectable with the highly sensitive assay in 39 (93%) of 42 patients with infective endocarditis and with the standard assay in 25 (56%) of 42 (p <0.05). Of the 42 patients, 15 experienced the composite outcome, 4 died, 9 had a central nervous system event, and 5 had a cardiac abscess. With the hs-cTnT assay, the median cTnT was greater in the patients who experienced the primary outcome (0.12 vs 0.02 ng/ml, p <0.05). According to the receiver operating characteristic curve analysis (area under the curve of 0.74), cTnT levels of ≥0.08 ng/ml produced optimal specificity (78%) for the primary outcome. The patients with a cTnT level of ≥0.08 ng/ml were more likely to experience the primary outcome (odds ratio 7.0, 95% confidence interval 1.7 to 28.6, p <0.01) and a central nervous system event (odds ratio 9.3, 95% confidence interval 1.3 to 24.1, p = 0.02). In conclusion, cTnT is detectable in 93% of patients with infective endocarditis using a novel highly sensitive assay, with higher levels correlating with poor clinical outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Blood troponin levels in acute cardiac events depends on space weather activity components (a correlative study).

    PubMed

    Stoupel, Eliiyahu; Radishauskas, Richardas; Bernotiene, Gailute; Tamoshiunas, Abdonas; Virvichiute, Daiva

    2018-02-05

    Many biological processes are influenced by space weather activity components such as solar activity (SA), geomagnetic activity (GMA) and cosmic ray activity (CRA). Examples are total mortality, acute myocardial infarction (AMI), stroke (cerebrovascular accident), sudden cardiac death, some congenital maladies (congenital heart disease and Down syndrome), many events in neonatology, ophtalmology, blood pressure regulation, blood coagulation, inflammation, etc. The aim of this study was to check if the level of blood troponins (Tns) - markers of myocardial damage and recognized components of modern description of AMI - is connected with the mentioned space weather parameters. Patients admitted to a 3000-bed tertiary university hospital in Kaunas, Lithuania, with suspected AMI were the object of the study. Data for the time between 2008 and 2013 - 72 consecutive months - were studied. Of the patients, 1896 (1398 male, 498 female) had elevated troponin I (Tn I) or troponin T (Tn T, sensitive Tn) levels. Normal values were 0.00-0.03 ng/mL for Tn I and 0.00-14.00 ng/mL for Tn T. Monthly means and standard deviation of Tn I and Tn T were compared with monthly markers of SA, GMA and CRA. Pearson correlation coefficients and their probabilities were established (in addition to the consecutive graphs of both comparing physical and biological data). The cosmophysical data came from space service institutions in the United States, Russia and Finland. AMI was diagnosed in 1188 patients (62.66%), and intermediate coronary syndrome in 698 patients (36.81%). There were significant links of the Tn blood levels with four SA indices and CRA (neutron activity in imp/min); there was no significant correlation with GMA indices Ap and Cp (p=0.27 and p=0.235). Tn T levels significantly correlated with the GMA indices and not with the SA and CRA levels (Ap: r=0.77, p=0.0021; Cp: r=0.729, p=0.0047). First, the monthly level of blood Tn I in ACS is significantly correlated with the indices of SA (inverse) and with CRA (neutron); second, no significant correlation with the GMA indices was found; and third, the Tn T levels showed significant links with the GMA indices and none with SA and CRA (neutron).

  7. High-sensitivity troponin I for risk assessment in patients with atrial fibrillation: insights from the Apixaban for Reduction in Stroke and other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) trial.

    PubMed

    Hijazi, Ziad; Siegbahn, Agneta; Andersson, Ulrika; Granger, Christopher B; Alexander, John H; Atar, Dan; Gersh, Bernard J; Mohan, Puneet; Harjola, Veli-Pekka; Horowitz, John; Husted, Steen; Hylek, Elaine M; Lopes, Renato D; McMurray, John J V; Wallentin, Lars

    2014-02-11

    High-sensitivity troponin-I (hs-TnI) measurement improves risk assessment for cardiovascular events in many clinical settings, but the added value in atrial fibrillation patients has not been described. At randomization, hs-TnI was analyzed in 14 821 atrial fibrillation patients in the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) trial comparing apixaban with warfarin. The associations between hs-TnI concentrations and clinical outcomes were evaluated by using adjusted Cox analysis. The hs-TnI assay detected troponin (≥1.3 ng/L) in 98.5% patients, 50% had levels >5.4, 25% had levels >10.1, and 9.2% had levels ≥23 ng/L (the 99th percentile in healthy individuals). During a median of 1.9 years follow-up, annual rates of stroke or systemic embolism ranged from 0.76% in the lowest hs-TnI quartile to 2.26% in the highest quartile (>10.1 ng/L). In multivariable analysis, hs-TnI was significantly associated with stroke or systemic embolism, adjusted hazard ratio 1.98 (1.42-2.78), P=0.0007. hs-TnI was also significantly associated with cardiac death; annual rates ranged from 0.40% to 4.24%, hazard ratio 4.52 (3.05-6.70), P<0.0001, in the corresponding groups, and for major bleeding hazard ratio 1.44 (1.11-1.86), P=0.0250. Adding hs-TnI levels to the CHA2DS2VASc score improved c-statistics from 0.629 to 0.653 for stroke or systemic embolism, and from 0.591 to 0.731 for cardiac death. There were no significant interactions with study treatment. Troponin-I is detected in 98.5% and elevated in 9.2% of atrial fibrillation patients. The hs-TnI level is independently associated with a raised risk of stroke, cardiac death, and major bleeding and improves risk stratification beyond the CHA2DS2VASc score. The benefits of apixaban in comparison with warfarin are consistent regardless of hs-TnI levels. http://www.clinicaltrials.gov. Unique identifier: NCT00412984.

  8. Conservation success as a function of good alignment of social and ecological structures and processes.

    PubMed

    Bodin, Orjan; Crona, Beatrice; Thyresson, Matilda; Golz, Anna-Lea; Tengö, Maria

    2014-10-01

    How to create and adjust governing institutions so that they align (fit) with complex ecosystem processes and structures across scales is an issue of increasing concern in conservation. It is argued that lack of such social-ecological fit makes governance and conservation difficult, yet progress in explicitly defining and rigorously testing what constitutes a good fit has been limited. We used a novel modeling approach and data from case studies of fishery and forest conservation to empirically test presumed relationships between conservation outcomes and certain patterns of alignment of social-ecological interdependences. Our approach made it possible to analyze conservation outcome on a systems level while also providing information on how individual actors are positioned in the complex web of social-ecological interdependencies. We found that when actors who shared resources were also socially linked, conservation at the level of the whole social-ecological system was positively affected. When the scales at which individual actors used resources and the scale at which ecological resources were interconnected to other ecological resources were aligned through tightened feedback loops, conservation outcome was better than when they were not aligned. The analysis of individual actors' positions in the web of social-ecological interdependencies was helpful in understanding why a system has a certain level of social-ecological fit. Results of analysis of positions showed that different actors contributed in very different ways to achieve a certain fit and revealed some underlying difference between the actors, for example in terms of actors' varying rights to access and use different ecological resources. © 2014 Society for Conservation Biology.

  9. SWPhylo - A Novel Tool for Phylogenomic Inferences by Comparison of Oligonucleotide Patterns and Integration of Genome-Based and Gene-Based Phylogenetic Trees.

    PubMed

    Yu, Xiaoyu; Reva, Oleg N

    2018-01-01

    Modern phylogenetic studies may benefit from the analysis of complete genome sequences of various microorganisms. Evolutionary inferences based on genome-scale analysis are believed to be more accurate than the gene-based alternative. However, the computational complexity of current phylogenomic procedures, inappropriateness of standard phylogenetic tools to process genome-wide data, and lack of reliable substitution models which correlates with alignment-free phylogenomic approaches deter microbiologists from using these opportunities. For example, the super-matrix and super-tree approaches of phylogenomics use multiple integrated genomic loci or individual gene-based trees to infer an overall consensus tree. However, these approaches potentially multiply errors of gene annotation and sequence alignment not mentioning the computational complexity and laboriousness of the methods. In this article, we demonstrate that the annotation- and alignment-free comparison of genome-wide tetranucleotide frequencies, termed oligonucleotide usage patterns (OUPs), allowed a fast and reliable inference of phylogenetic trees. These were congruent to the corresponding whole genome super-matrix trees in terms of tree topology when compared with other known approaches including 16S ribosomal RNA and GyrA protein sequence comparison, complete genome-based MAUVE, and CVTree methods. A Web-based program to perform the alignment-free OUP-based phylogenomic inferences was implemented at http://swphylo.bi.up.ac.za/. Applicability of the tool was tested on different taxa from subspecies to intergeneric levels. Distinguishing between closely related taxonomic units may be enforced by providing the program with alignments of marker protein sequences, eg, GyrA.

  10. SWPhylo – A Novel Tool for Phylogenomic Inferences by Comparison of Oligonucleotide Patterns and Integration of Genome-Based and Gene-Based Phylogenetic Trees

    PubMed Central

    Yu, Xiaoyu; Reva, Oleg N

    2018-01-01

    Modern phylogenetic studies may benefit from the analysis of complete genome sequences of various microorganisms. Evolutionary inferences based on genome-scale analysis are believed to be more accurate than the gene-based alternative. However, the computational complexity of current phylogenomic procedures, inappropriateness of standard phylogenetic tools to process genome-wide data, and lack of reliable substitution models which correlates with alignment-free phylogenomic approaches deter microbiologists from using these opportunities. For example, the super-matrix and super-tree approaches of phylogenomics use multiple integrated genomic loci or individual gene-based trees to infer an overall consensus tree. However, these approaches potentially multiply errors of gene annotation and sequence alignment not mentioning the computational complexity and laboriousness of the methods. In this article, we demonstrate that the annotation- and alignment-free comparison of genome-wide tetranucleotide frequencies, termed oligonucleotide usage patterns (OUPs), allowed a fast and reliable inference of phylogenetic trees. These were congruent to the corresponding whole genome super-matrix trees in terms of tree topology when compared with other known approaches including 16S ribosomal RNA and GyrA protein sequence comparison, complete genome-based MAUVE, and CVTree methods. A Web-based program to perform the alignment-free OUP-based phylogenomic inferences was implemented at http://swphylo.bi.up.ac.za/. Applicability of the tool was tested on different taxa from subspecies to intergeneric levels. Distinguishing between closely related taxonomic units may be enforced by providing the program with alignments of marker protein sequences, eg, GyrA. PMID:29511354

  11. Mechanically Oriented 3D Collagen Hydrogel for Directing Neurite Growth.

    PubMed

    Antman-Passig, Merav; Levy, Shahar; Gartenberg, Chaim; Schori, Hadas; Shefi, Orit

    2017-05-01

    Recent studies in the field of neuro-tissue engineering have demonstrated the promising effects of aligned contact guidance cue to scaffolds of enhancement and direction of neuronal growth. In vivo, neurons grow and develop neurites in a complex three-dimensional (3D) extracellular matrix (ECM) surrounding. Studies have utilized hydrogel scaffolds derived from ECM molecules to better simulate natural growth. While many efforts have been made to control neuronal growth on 2D surfaces, the development of 3D scaffolds with an elaborate oriented topography to direct neuronal growth still remains a challenge. In this study, we designed a method for growing neurons in an aligned and oriented 3D collagen hydrogel. We aligned collagen fibers by inducing controlled uniaxial strain on gels. To examine the collagen hydrogel as a suitable scaffold for neuronal growth, we evaluated the physical properties of the hydrogel and measured collagen fiber properties. By combining the neuronal culture in 3D collagen hydrogels with strain-induced alignment, we were able to direct neuronal growth in the direction of the aligned collagen matrix. Quantitative evaluation of neurite extension and directionality within aligned gels was performed. The analysis showed neurite growth aligned with collagen matrix orientation, while maintaining the advantageous 3D growth.

  12. Robust algorithm for aligning two-dimensional chromatograms.

    PubMed

    Gros, Jonas; Nabi, Deedar; Dimitriou-Christidis, Petros; Rutler, Rebecca; Arey, J Samuel

    2012-11-06

    Comprehensive two-dimensional gas chromatography (GC × GC) chromatograms typically exhibit run-to-run retention time variability. Chromatogram alignment is often a desirable step prior to further analysis of the data, for example, in studies of environmental forensics or weathering of complex mixtures. We present a new algorithm for aligning whole GC × GC chromatograms. This technique is based on alignment points that have locations indicated by the user both in a target chromatogram and in a reference chromatogram. We applied the algorithm to two sets of samples. First, we aligned the chromatograms of twelve compositionally distinct oil spill samples, all analyzed using the same instrument parameters. Second, we applied the algorithm to two compositionally distinct wastewater extracts analyzed using two different instrument temperature programs, thus involving larger retention time shifts than the first sample set. For both sample sets, the new algorithm performed favorably compared to two other available alignment algorithms: that of Pierce, K. M.; Wood, Lianna F.; Wright, B. W.; Synovec, R. E. Anal. Chem.2005, 77, 7735-7743 and 2-D COW from Zhang, D.; Huang, X.; Regnier, F. E.; Zhang, M. Anal. Chem.2008, 80, 2664-2671. The new algorithm achieves the best matches of retention times for test analytes, avoids some artifacts which result from the other alignment algorithms, and incurs the least modification of quantitative signal information.

  13. Potential Anti-Inflammatory Treatment of Ischemic Heart Disease

    PubMed Central

    Hodzic, Enisa

    2018-01-01

    Introduction Ischemic heart disease (IHD) is clinical manifestation of chronic inflammatory progressive pathological process of atherosclerosis in coronary arteries. IHD is the leading cause of morbidity and mortality in the world. The question is whether it is possible to improve and direct the therapeutic treatment of IHD patients in the treatment of the inflammatory process in the atherosclerotic leasions. Material and Methods A prospective, comparative, analytica,clinically applicable, open-type study was performed. The study was conducted on 80 subjects with controlled biohumoral markers: troponin, CK, CK MB, BNP; markers of atherogenesis: LDL and homocystein; inflammatory markers: CRP, amyloid, cytokines IL-2, IL-6,TNF-alpha. The experimental group of 38 respondents had in addition to the conventional IHD treatment with: ampicillin (which included organosulfur compounds), cyancobalamin, vitamin B complex (B1, B2 and B6) and folacin. A control group of 42 respondents did not have this additional treatment. Results Major adverse cardic events (MACE) such as postinfarctic angina pectoris and repeated infarction, need for surgical interventions of myocardial revascularization, signs of cardiac insufficiency and death were observed during the one-year period. There was no correlation between the IL-2, IL-6 and TNF-alpha, as well as CK, CKMB and troponin and MACE in one-year follow-up. There was a strong positive correlation between MACE and CRP (p = 0,0002) and amyloid (p = 0,0005) as inflamatory markers; a strong positive correlation between MACE and homocysteine as an atherogenic marker (p = 0,0002, and amoderate positive correlation between MACE and BNP (p = 0.0403) as ischemic marker and marker of cardiac insufficiency. The echocardiographically monitored systolic function showed a moderate difference in the groups with average higher values in the experimantal group (p = 0.0282). Conclusion The applied treatment exhibited a moderate positive effect on the systolic function of LV and significantly reduced the MACE in the work compared to the control group (p <0.0001), and demonstrated a potential anti-inflammatory effect. PMID:29736096

  14. Electron Tomography of Cryofixed, Isometrically Contracting Insect Flight Muscle Reveals Novel Actin-Myosin Interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Shenping; Liu, Jun; Reedy, Mary C.

    2010-10-22

    Isometric muscle contraction, where force is generated without muscle shortening, is a molecular traffic jam in which the number of actin-attached motors is maximized and all states of motor action are trapped with consequently high heterogeneity. This heterogeneity is a major limitation to deciphering myosin conformational changes in situ. We used multivariate data analysis to group repeat segments in electron tomograms of isometrically contracting insect flight muscle, mechanically monitored, rapidly frozen, freeze substituted, and thin sectioned. Improved resolution reveals the helical arrangement of F-actin subunits in the thin filament enabling an atomic model to be built into the thin filamentmore » density independent of the myosin. Actin-myosin attachments can now be assigned as weak or strong by their motor domain orientation relative to actin. Myosin attachments were quantified everywhere along the thin filament including troponin. Strong binding myosin attachments are found on only four F-actin subunits, the 'target zone', situated exactly midway between successive troponin complexes. They show an axial lever arm range of 77{sup o}/12.9 nm. The lever arm azimuthal range of strong binding attachments has a highly skewed, 127{sup o} range compared with X-ray crystallographic structures. Two types of weak actin attachments are described. One type, found exclusively in the target zone, appears to represent pre-working-stroke intermediates. The other, which contacts tropomyosin rather than actin, is positioned M-ward of the target zone, i.e. the position toward which thin filaments slide during shortening. We present a model for the weak to strong transition in the myosin ATPase cycle that incorporates azimuthal movements of the motor domain on actin. Stress/strain in the S2 domain may explain azimuthal lever arm changes in the strong binding attachments. The results support previous conclusions that the weak attachments preceding force generation are very different from strong binding attachments.« less

  15. Rapid and Sensitive Detection of Cardiac Troponin I for Point-of-Care Tests Based on Red Fluorescent Microspheres.

    PubMed

    Cai, Yanxue; Kang, Keren; Li, Qianru; Wang, Yu; He, Xiaowei

    2018-05-07

    A reliable lateral flow immunoassay (LFIA) based on a facile one-step synthesis of single microspheres in combining with immunochromatography technique was developed to establish a new point-of-care test (POCT) for the rapid and early detection of cardiac troponin I (cTnI), a kind of cardiac specific biomarker for acute myocardial infarction (AMI). The double layered microspheres with clear core-shell structures were produced using soap-free emulsion polymerization method with inexpensive compounds (styrene and acrylic acid). The synthetic process was simple, rapid and easy to control due to one-step synthesis without any complicated procedures. The microspheres are nanostructure with high surface area, which have numerous carboxyl groups on the out layer, resulting in high-efficiency coupling between the carrier and antibody via amide bond. Meanwhile, the red fluorescent dye, Nile-red (NR), was wrapped inside the microspheres to improve its stability, as well to reduce the background noise, because of its higher emission wavelength than interference from real plasma samples. The core-shell structures provided different functional areas to separate antibody and dyes, so the immunoassay has highly sensitive, wide working curves in the range of 0⁻40 ng/mL, low limits of detection (LOD) at 0.016 ng/mL, and limits of quantification (LOQ) at 0.087 ng/mL with coefficient of variations (CV) of 10%. This strategy suggested an outstanding platform for LFIA, with good reproducibility and stability to straightforwardly analyze the plasma samples without washing steps, thereby reducing the operating procedures for non-professionals and promoting detection efficiency. The whole detection process can be completed in less than 15 min. This novel immunoassay offers a reliable and favorable analytical result by detecting the real samples, indicating that it holds great potential as a new alternative for biomolecule detection in complex samples, for the early detection of cardiac specific biomarkers.

  16. Optical Device for Converting a Laser Beam into Two Co-aligned but Oppositely Directed Beams

    NASA Technical Reports Server (NTRS)

    Jennings, Donald

    2013-01-01

    Optical systems consisting of a series of optical elements require alignment from the input end to the output end. The optical elements can be mirrors, lenses, sources, detectors, or other devices. Complex optical systems are often difficult to align from end-to-end because the alignment beam must be inserted at one end in order for the beam to traverse the entire optical path to the other end. The ends of the optical train may not be easily accessible to the alignment beam. Typically, when a series of optical elements is to be aligned, an alignment laser beam is inserted into the optical path with a pick-off mirror at one end of the series of elements. But it may be impossible to insert the beam at an end-point. It can be difficult to locate the pick-off mirror at the desired position because there is not enough space, there is no mounting surface, or the location is occupied by a source, detector, or other component. Alternatively, the laser beam might be inserted at an intermediate location (not at an end-point) and sent, first in one direction and then the other, to the opposite ends of the optical system for alignment. However, in this case, alignment must be performed in two directions and extra effort is required to co-align the two beams to make them parallel and coincident, i.e., to follow the same path as an end-to-end beam. An optical device has been developed that accepts a laser beam as input and produces two co-aligned, but counter-propagating beams. In contrast to a conventional alignment laser placed at one end of the optical path, this invention can be placed at a convenient position within the optical train and aligned to send its two beams simultaneously along precisely opposite paths that, taken together, trace out exactly the same path as the conventional alignment laser. This invention allows the user the freedom to choose locations within the optical train for placement of the alignment beam. It is also self-aligned by design and requires almost no adjustment.

  17. Numerical Upscaling of Solute Transport in Fractured Porous Media Based on Flow Aligned Blocks

    NASA Astrophysics Data System (ADS)

    Leube, P.; Nowak, W.; Sanchez-Vila, X.

    2013-12-01

    High-contrast or fractured-porous media (FPM) pose one of the largest unresolved challenges for simulating large hydrogeological systems. The high contrast in advective transport between fast conduits and low-permeability rock matrix, including complex mass transfer processes, leads to the typical complex characteristics of early bulk arrivals and long tailings. Adequate direct representation of FPM requires enormous numerical resolutions. For large scales, e.g. the catchment scale, and when allowing for uncertainty in the fracture network architecture or in matrix properties, computational costs quickly reach an intractable level. In such cases, multi-scale simulation techniques have become useful tools. They allow decreasing the complexity of models by aggregating and transferring their parameters to coarser scales and so drastically reduce the computational costs. However, these advantages come at a loss of detail and accuracy. In this work, we develop and test a new multi-scale or upscaled modeling approach based on block upscaling. The novelty is that individual blocks are defined by and aligned with the local flow coordinates. We choose a multi-rate mass transfer (MRMT) model to represent the remaining sub-block non-Fickian behavior within these blocks on the coarse scale. To make the scale transition simple and to save computational costs, we capture sub-block features by temporal moments (TM) of block-wise particle arrival times to be matched with the MRMT model. By predicting spatial mass distributions of injected tracers in a synthetic test scenario, our coarse-scale solution matches reasonably well with the corresponding fine-scale reference solution. For predicting higher TM-orders (such as arrival time and effective dispersion), the prediction accuracy steadily decreases. This is compensated to some extent by the MRMT model. If the MRMT model becomes too complex, it loses its effect. We also found that prediction accuracy is sensitive to the choice of the effective dispersion coefficients and on the block resolution. A key advantage of the flow-aligned blocks is that the small-scale velocity field is reproduced quite accurately on the block-scale through their flow alignment. Thus, the block-scale transverse dispersivities remain in the similar magnitude as local ones, and they do not have to represent macroscopic uncertainty. Also, the flow-aligned blocks minimize numerical dispersion when solving the large-scale transport problem.

  18. Aligning "TextEvaluator"® Scores with the Accelerated Text Complexity Guidelines Specified in the Common Core State Standards. Research Report. ETS RR-15-21

    ERIC Educational Resources Information Center

    Sheehan, Kathleen M.

    2015-01-01

    The "TextEvaluator"® text analysis tool is a fully automated text complexity evaluation tool designed to help teachers, curriculum specialists, textbook publishers, and test developers select texts that are consistent with the text complexity guidelines specified in the Common Core State Standards.This paper documents the procedure used…

  19. Generating Automated Text Complexity Classifications That Are Aligned with Targeted Text Complexity Standards. Research Report. ETS RR-10-28

    ERIC Educational Resources Information Center

    Sheehan, Kathleen M.; Kostin, Irene; Futagi, Yoko; Flor, Michael

    2010-01-01

    The Common Core Standards call for students to be exposed to a much greater level of text complexity than has been the norm in schools for the past 40 years. Textbook publishers, teachers, and assessment developers are being asked to refocus materials and methods to ensure that students are challenged to read texts at steadily increasing…

  20. Interfacial charge separation and recombination in InP and quasi-type II InP/CdS core/shell quantum dot-molecular acceptor complexes.

    PubMed

    Wu, Kaifeng; Song, Nianhui; Liu, Zheng; Zhu, Haiming; Rodríguez-Córdoba, William; Lian, Tianquan

    2013-08-15

    Recent studies of group II-VI colloidal semiconductor heterostuctures, such as CdSe/CdS core/shell quantum dots (QDs) or dot-in-rod nanorods, show that type II and quasi-type II band alignment can facilitate electron transfer and slow down charge recombination in QD-molecular electron acceptor complexes. To explore the general applicability of this wave function engineering approach for controlling charge transfer properties, we investigate exciton relaxation and dissociation dynamics in InP (a group III-V semiconductor) and InP/CdS core/shell (a heterostructure beween group III-V and II-VI semiconductors) QDs by transient absorption spectroscopy. We show that InP/CdS QDs exhibit a quasi-type II band alignment with the 1S electron delocalized throughout the core and shell and the 1S hole confined in the InP core. In InP-methylviologen (MV(2+)) complexes, excitons in the QD can be dissociated by ultrafast electron transfer to MV(2+) from the 1S electron level (with an average time constant of 11.4 ps) as well as 1P and higher electron levels (with a time constant of 0.39 ps), which is followed by charge recombination to regenerate the complex in its ground state (with an average time constant of 47.1 ns). In comparison, InP/CdS-MV(2+) complexes show similar ultrafast charge separation and 5-fold slower charge recombination rates, consistent with the quasi-type II band alignment in these heterostructures. This result demonstrates that wave function engineering in nanoheterostructures of group III-V and II-VI semiconductors provides a promising approach for optimizing their light harvesting and charge separation for solar energy conversion applications.

  1. An Alignment Model for Collaborative Value Networks

    NASA Astrophysics Data System (ADS)

    Bremer, Carlos; Azevedo, Rodrigo Cambiaghi; Klen, Alexandra Pereira

    This paper presents parts of the work carried out in several global organizations through the development of strategic projects with high tactical and operational complexity. By investing in long-term relationships, strongly operating in the transformation of the competitive model and focusing on the value chain management, the main aim of these projects was the alignment of multiple value chains. The projects were led by the Axia Transformation Methodology as well as by its Management Model and following the principles of Project Management. As a concrete result of the efforts made in the last years in the Brazilian market this work also introduces the Alignment Model which supports the transformation process that the companies undergo.

  2. 3D-Printing of Meso-structurally Ordered Carbon Fiber/Polymer Composites with Unprecedented Orthotropic Physical Properties

    NASA Astrophysics Data System (ADS)

    Lewicki, James P.; Rodriguez, Jennifer N.; Zhu, Cheng; Worsley, Marcus A.; Wu, Amanda S.; Kanarska, Yuliya; Horn, John D.; Duoss, Eric B.; Ortega, Jason M.; Elmer, William; Hensleigh, Ryan; Fellini, Ryan A.; King, Michael J.

    2017-03-01

    Here we report the first example of a class of additively manufactured carbon fiber reinforced composite (AMCFRC) materials which have been achieved through the use of a latent thermal cured aromatic thermoset resin system, through an adaptation of direct ink writing (DIW) 3D-printing technology. We have developed a means of printing high performance thermoset carbon fiber composites, which allow the fiber component of a resin and carbon fiber fluid to be aligned in three dimensions via controlled micro-extrusion and subsequently cured into complex geometries. Characterization of our composite systems clearly show that we achieved a high order of fiber alignment within the composite microstructure, which in turn allows these materials to outperform equivalently filled randomly oriented carbon fiber and polymer composites. Furthermore, our AM carbon fiber composite systems exhibit highly orthotropic mechanical and electrical responses as a direct result of the alignment of carbon fiber bundles in the microscale which we predict will ultimately lead to the design of truly tailorable carbon fiber/polymer hybrid materials having locally programmable complex electrical, thermal and mechanical response.

  3. Nature of the water/aromatic parallel alignment interactions.

    PubMed

    Mitoraj, Mariusz P; Janjić, Goran V; Medaković, Vesna B; Veljković, Dušan Ž; Michalak, Artur; Zarić, Snežana D; Milčić, Miloš K

    2015-01-30

    The water/aromatic parallel alignment interactions are interactions where the water molecule or one of its O-H bonds is parallel to the aromatic ring plane. The calculated energies of the interactions are significant, up to ΔE(CCSD)(T)(limit) = -2.45 kcal mol(-1) at large horizontal displacement, out of benzene ring and CH bond region. These interactions are stronger than CH···O water/benzene interactions, but weaker than OH···π interactions. To investigate the nature of water/aromatic parallel alignment interactions, energy decomposition methods, symmetry-adapted perturbation theory, and extended transition state-natural orbitals for chemical valence (NOCV), were used. The calculations have shown that, for the complexes at large horizontal displacements, major contribution to interaction energy comes from electrostatic interactions between monomers, and for the complexes at small horizontal displacements, dispersion interactions are dominant binding force. The NOCV-based analysis has shown that in structures with strong interaction energies charge transfer of the type π → σ*(O-H) between the monomers also exists. © 2014 Wiley Periodicals, Inc.

  4. 3D-Printing of Meso-structurally Ordered Carbon Fiber/Polymer Composites with Unprecedented Orthotropic Physical Properties.

    PubMed

    Lewicki, James P; Rodriguez, Jennifer N; Zhu, Cheng; Worsley, Marcus A; Wu, Amanda S; Kanarska, Yuliya; Horn, John D; Duoss, Eric B; Ortega, Jason M; Elmer, William; Hensleigh, Ryan; Fellini, Ryan A; King, Michael J

    2017-03-06

    Here we report the first example of a class of additively manufactured carbon fiber reinforced composite (AMCFRC) materials which have been achieved through the use of a latent thermal cured aromatic thermoset resin system, through an adaptation of direct ink writing (DIW) 3D-printing technology. We have developed a means of printing high performance thermoset carbon fiber composites, which allow the fiber component of a resin and carbon fiber fluid to be aligned in three dimensions via controlled micro-extrusion and subsequently cured into complex geometries. Characterization of our composite systems clearly show that we achieved a high order of fiber alignment within the composite microstructure, which in turn allows these materials to outperform equivalently filled randomly oriented carbon fiber and polymer composites. Furthermore, our AM carbon fiber composite systems exhibit highly orthotropic mechanical and electrical responses as a direct result of the alignment of carbon fiber bundles in the microscale which we predict will ultimately lead to the design of truly tailorable carbon fiber/polymer hybrid materials having locally programmable complex electrical, thermal and mechanical response.

  5. 3D-Printing of Meso-structurally Ordered Carbon Fiber/Polymer Composites with Unprecedented Orthotropic Physical Properties

    PubMed Central

    Lewicki, James P.; Rodriguez, Jennifer N.; Zhu, Cheng; Worsley, Marcus A.; Wu, Amanda S.; Kanarska, Yuliya; Horn, John D.; Duoss, Eric B.; Ortega, Jason M.; Elmer, William; Hensleigh, Ryan; Fellini, Ryan A.; King, Michael J.

    2017-01-01

    Here we report the first example of a class of additively manufactured carbon fiber reinforced composite (AMCFRC) materials which have been achieved through the use of a latent thermal cured aromatic thermoset resin system, through an adaptation of direct ink writing (DIW) 3D-printing technology. We have developed a means of printing high performance thermoset carbon fiber composites, which allow the fiber component of a resin and carbon fiber fluid to be aligned in three dimensions via controlled micro-extrusion and subsequently cured into complex geometries. Characterization of our composite systems clearly show that we achieved a high order of fiber alignment within the composite microstructure, which in turn allows these materials to outperform equivalently filled randomly oriented carbon fiber and polymer composites. Furthermore, our AM carbon fiber composite systems exhibit highly orthotropic mechanical and electrical responses as a direct result of the alignment of carbon fiber bundles in the microscale which we predict will ultimately lead to the design of truly tailorable carbon fiber/polymer hybrid materials having locally programmable complex electrical, thermal and mechanical response. PMID:28262669

  6. B-cell Ligand Processing Pathways Detected by Large-scale Comparative Analysis

    PubMed Central

    Towfic, Fadi; Gupta, Shakti; Honavar, Vasant; Subramaniam, Shankar

    2012-01-01

    The initiation of B-cell ligand recognition is a critical step for the generation of an immune response against foreign bodies. We sought to identify the biochemical pathways involved in the B-cell ligand recognition cascade and sets of ligands that trigger similar immunological responses. We utilized several comparative approaches to analyze the gene coexpression networks generated from a set of microarray experiments spanning 33 different ligands. First, we compared the degree distributions of the generated networks. Second, we utilized a pairwise network alignment algorithm, BiNA, to align the networks based on the hubs in the networks. Third, we aligned the networks based on a set of KEGG pathways. We summarized our results by constructing a consensus hierarchy of pathways that are involved in B cell ligand recognition. The resulting pathways were further validated through literature for their common physiological responses. Collectively, the results based on our comparative analyses of degree distributions, alignment of hubs, and alignment based on KEGG pathways provide a basis for molecular characterization of the immune response states of B-cells and demonstrate the power of comparative approaches (e.g., gene coexpression network alignment algorithms) in elucidating biochemical pathways involved in complex signaling events in cells. PMID:22917187

  7. Acute alcohol intoxication impairs segmental body alignment in upright standing.

    PubMed

    Hafstrom, A; Patel, M; Modig, F; Magnusson, M; Fransson, P A

    2014-01-01

    Balance control when standing upright is a complex process requiring input from several partly independent mechanisms such as coordination, feedback and feedforward control, and adaptation. Acute alcohol intoxication from ethanol is recognized as a major contributor to accidental falls requiring medical care. This study aimed to investigate if intoxication at 0.06 and 0.10% blood alcohol concentration affected body alignment. Mean angular positions of the head, shoulder, hip, and knee were measured with 3D-motion analysis and compared with the ankle position in 25 healthy adults during standing with or without perturbations, and with eyes open or closed. Alcohol intoxication had significant effects on body alignment during perturbed and unperturbed stance, and on adaptation to perturbations. It induced a significantly more posterior alignment of the knees and shoulders, and a tendency for a more posterior and left deviated head alignment in perturbed stance than when sober. The impact of alcohol intoxication was most apparent on the knee alignment, where availability of visual information deteriorated the adaptation to perturbations. Thus, acute alcohol intoxication resulted in inadequate balance control strategies with increased postural rigidity and impaired adaptation to perturbations. These factors probably contribute to the increased risk of falling when intoxicated with alcohol.

  8. Self-aligned block technology: a step toward further scaling

    NASA Astrophysics Data System (ADS)

    Lazzarino, Frédéric; Mohanty, Nihar; Feurprier, Yannick; Huli, Lior; Luong, Vinh; Demand, Marc; Decoster, Stefan; Vega Gonzalez, Victor; Ryckaert, Julien; Kim, Ryan Ryoung Han; Mallik, Arindam; Leray, Philippe; Wilson, Chris; Boemmels, Jürgen; Kumar, Kaushik; Nafus, Kathleen; deVilliers, Anton; Smith, Jeffrey; Fonseca, Carlos; Bannister, Julie; Scheer, Steven; Tokei, Zsolt; Piumi, Daniele; Barla, Kathy

    2017-04-01

    In this work, we present and compare two integration approaches to enable self-alignment of the block suitable for the 5- nm technology node. The first approach is exploring the insertion of a spin-on metal-based material to memorize the first block and act as an etch stop layer in the overall integration. The second approach is evaluating the self-aligned block technology employing widely used organic materials and well-known processes. The concept and the motivation are discussed considering the effects on design and mask count as well as the impact on process complexity and EPE budget. We show the integration schemes and discuss the requirements to enable self-alignment. We present the details of materials and processes selection to allow optimal selective etches and we demonstrate the proof of concept using a 16- nm half-pitch BEOL vehicle. Finally, a study on technology insertion and cost estimation is presented.

  9. Energy-level alignment at organic heterointerfaces

    PubMed Central

    Oehzelt, Martin; Akaike, Kouki; Koch, Norbert; Heimel, Georg

    2015-01-01

    Today’s champion organic (opto-)electronic devices comprise an ever-increasing number of different organic-semiconductor layers. The functionality of these complex heterostructures largely derives from the relative alignment of the frontier molecular-orbital energies in each layer with respect to those in all others. Despite the technological relevance of the energy-level alignment at organic heterointerfaces, and despite continued scientific interest, a reliable model that can quantitatively predict the full range of phenomena observed at such interfaces is notably absent. We identify the limitations of previous attempts to formulate such a model and highlight inconsistencies in the interpretation of the experimental data they were based on. We then develop a theoretical framework, which we demonstrate to accurately reproduce experiment. Applying this theory, a comprehensive overview of all possible energy-level alignment scenarios that can be encountered at organic heterojunctions is finally given. These results will help focus future efforts on developing functional organic interfaces for superior device performance. PMID:26702447

  10. Linear Transceiver Design for Interference Alignment: Complexity and Computation

    DTIC Science & Technology

    2010-07-01

    restriction on the choice of beamforming vector of node b. Thus, for any fixed transmit node b in H , there are multiple restriction sets, each...signal space can be chosen. The receive nodes in H can achieve interference alignment if and only if these restricted sets of one-dimensional signal...total number of restriction sets is at most linear in the number of edges in H and each restriction set contains at most two one-dimensional

  11. Electron tomography simulator with realistic 3D phantom for evaluation of acquisition, alignment and reconstruction methods.

    PubMed

    Wan, Xiaohua; Katchalski, Tsvi; Churas, Christopher; Ghosh, Sreya; Phan, Sebastien; Lawrence, Albert; Hao, Yu; Zhou, Ziying; Chen, Ruijuan; Chen, Yu; Zhang, Fa; Ellisman, Mark H

    2017-05-01

    Because of the significance of electron microscope tomography in the investigation of biological structure at nanometer scales, ongoing improvement efforts have been continuous over recent years. This is particularly true in the case of software developments. Nevertheless, verification of improvements delivered by new algorithms and software remains difficult. Current analysis tools do not provide adaptable and consistent methods for quality assessment. This is particularly true with images of biological samples, due to image complexity, variability, low contrast and noise. We report an electron tomography (ET) simulator with accurate ray optics modeling of image formation that includes curvilinear trajectories through the sample, warping of the sample and noise. As a demonstration of the utility of our approach, we have concentrated on providing verification of the class of reconstruction methods applicable to wide field images of stained plastic-embedded samples. Accordingly, we have also constructed digital phantoms derived from serial block face scanning electron microscope images. These phantoms are also easily modified to include alignment features to test alignment algorithms. The combination of more realistic phantoms with more faithful simulations facilitates objective comparison of acquisition parameters, alignment and reconstruction algorithms and their range of applicability. With proper phantoms, this approach can also be modified to include more complex optical models, including distance-dependent blurring and phase contrast functions, such as may occur in cryotomography. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Challenges in Aligning Workplace Learning with Business Goals: A Perspective from HRD Professionals in New Zealand

    ERIC Educational Resources Information Center

    Short, Tom; Harris, Roger

    2010-01-01

    Modern organisations have become more complex, less mechanistic and increasingly sensitive to rapid changes in the external environment than in previous eras. Today, executives lead employees through a maze of complexity and changing contexts. However, another group of dedicated professionals, the human resource managers and practitioners, also…

  13. GenomeVista

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poliakov, Alexander; Couronne, Olivier

    2002-11-04

    Aligning large vertebrate genomes that are structurally complex poses a variety of problems not encountered on smaller scales. Such genomes are rich in repetitive elements and contain multiple segmental duplications, which increases the difficulty of identifying true orthologous SNA segments in alignments. The sizes of the sequences make many alignment algorithms designed for comparing single proteins extremely inefficient when processing large genomic intervals. We integrated both local and global alignment tools and developed a suite of programs for automatically aligning large vertebrate genomes and identifying conserved non-coding regions in the alignments. Our method uses the BLAT local alignment program tomore » find anchors on the base genome to identify regions of possible homology for a query sequence. These regions are postprocessed to find the best candidates which are then globally aligned using the AVID global alignment program. In the last step conserved non-coding segments are identified using VISTA. Our methods are fast and the resulting alignments exhibit a high degree of sensitivity, covering more than 90% of known coding exons in the human genome. The GenomeVISTA software is a suite of Perl programs that is built on a MySQL database platform. The scheduler gets control data from the database, builds a queve of jobs, and dispatches them to a PC cluster for execution. The main program, running on each node of the cluster, processes individual sequences. A Perl library acts as an interface between the database and the above programs. The use of a separate library allows the programs to function independently of the database schema. The library also improves on the standard Perl MySQL database interfere package by providing auto-reconnect functionality and improved error handling.« less

  14. Optimizing multiple sequence alignments using a genetic algorithm based on three objectives: structural information, non-gaps percentage and totally conserved columns.

    PubMed

    Ortuño, Francisco M; Valenzuela, Olga; Rojas, Fernando; Pomares, Hector; Florido, Javier P; Urquiza, Jose M; Rojas, Ignacio

    2013-09-01

    Multiple sequence alignments (MSAs) are widely used approaches in bioinformatics to carry out other tasks such as structure predictions, biological function analyses or phylogenetic modeling. However, current tools usually provide partially optimal alignments, as each one is focused on specific biological features. Thus, the same set of sequences can produce different alignments, above all when sequences are less similar. Consequently, researchers and biologists do not agree about which is the most suitable way to evaluate MSAs. Recent evaluations tend to use more complex scores including further biological features. Among them, 3D structures are increasingly being used to evaluate alignments. Because structures are more conserved in proteins than sequences, scores with structural information are better suited to evaluate more distant relationships between sequences. The proposed multiobjective algorithm, based on the non-dominated sorting genetic algorithm, aims to jointly optimize three objectives: STRIKE score, non-gaps percentage and totally conserved columns. It was significantly assessed on the BAliBASE benchmark according to the Kruskal-Wallis test (P < 0.01). This algorithm also outperforms other aligners, such as ClustalW, Multiple Sequence Alignment Genetic Algorithm (MSA-GA), PRRP, DIALIGN, Hidden Markov Model Training (HMMT), Pattern-Induced Multi-sequence Alignment (PIMA), MULTIALIGN, Sequence Alignment Genetic Algorithm (SAGA), PILEUP, Rubber Band Technique Genetic Algorithm (RBT-GA) and Vertical Decomposition Genetic Algorithm (VDGA), according to the Wilcoxon signed-rank test (P < 0.05), whereas it shows results not significantly different to 3D-COFFEE (P > 0.05) with the advantage of being able to use less structures. Structural information is included within the objective function to evaluate more accurately the obtained alignments. The source code is available at http://www.ugr.es/~fortuno/MOSAStrE/MO-SAStrE.zip.

  15. Molecular Defects in Cardiac Myofilament Ca2+-Regulation Due to Cardiomyopathy-Linked Mutations Can Be Reversed by Small Molecules Binding to Troponin.

    PubMed

    Sheehan, Alice; Messer, Andrew E; Papadaki, Maria; Choudhry, Afnan; Kren, Vladimír; Biedermann, David; Blagg, Brian; Khandelwal, Anuj; Marston, Steven B

    2018-01-01

    The inherited cardiomyopathies, hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM) are relatively common, potentially life-threatening and currently untreatable. Mutations are often in the contractile proteins of cardiac muscle and cause abnormal Ca 2+ regulation via troponin. HCM is usually linked to higher myofilament Ca 2+ -sensitivity whilst in both HCM and DCM mutant tissue there is often an uncoupling of the relationship between troponin I (TnI) phosphorylation by PKA and modulation of myofilament Ca 2+ -sensitivity, essential for normal responses to adrenaline. The adrenergic response is blunted, and this may predispose the heart to failure under stress. At present there are no compounds or interventions that can prevent or treat sarcomere cardiomyopathies. There is a need for novel therapies that act at a more fundamental level to affect the disease process. We demonstrated that epigallocatechin-3 gallate (EGCG) was found to be capable of restoring the coupled relationship between Ca 2+ -sensitivity and TnI phosphorylation in mutant thin filaments to normal in vitro , independent of the mutation (15 mutations tested). We have labeled this property "re-coupling." The action of EGCG in vitro to reverse the abnormality caused by myopathic mutations would appear to be an ideal pharmaceutical profile for treatment of inherited HCM and DCM but EGCG is known to be promiscuous in vivo and is thus unsuitable as a therapeutic drug. We therefore investigated whether other structurally related compounds can re-couple myofilaments without these off-target effects. We used the quantitative in vitro motility assay to screen 40 compounds, related to C-terminal Hsp90 inhibitors, and found 23 that can re-couple mutant myofilaments. There is no correlation between re-couplers and Hsp90 inhibitors. The Ca 2+ -sensitivity shift due to TnI phosphorylation was restored to 2.2 ± 0.01-fold ( n = 19) compared to 2.0 ± 0.24-fold ( n = 7) in wild-type thin filaments. Many of these compounds were either pure re-couplers or pure desensitizers, indicating these properties are independent; moreover, re-coupling ability could be lost with small changes of compound structure, indicating the possibility of specificity. Small molecules that can re-couple may have therapeutic potential. HIGHLIGHTS - Inherited cardiomyopathies are common diseases that are currently untreatable at a fundamental level and therefore finding a small molecule treatment is highly desirable.- We have identified a molecular level dysfunction common to nearly all mutations: uncoupling of the relationship between troponin I phosphorylation and modulation of myofilament Ca 2+ -sensitivity, essential for normal responses to adrenaline.- We have identified a new class of drugs that are capable of both reducing Ca 2+ -sensitivity and/or recouping the relationship between troponin I phosphorylation and Ca 2+ -sensitivity.- The re-coupling phenomenon can be explained on the basis of a single mechanism that is testable.- Measurements with a wide range of small molecules of varying structures can indicate the critical molecular features required for recoupling and allows the prediction of other potential re-couplers.

  16. Analytical structure, dynamics, and coarse graining of a kinetic model of an active fluid

    NASA Astrophysics Data System (ADS)

    Gao, Tong; Betterton, Meredith D.; Jhang, An-Sheng; Shelley, Michael J.

    2017-09-01

    We analyze one of the simplest active suspensions with complex dynamics: a suspension of immotile "extensor" particles that exert active extensile dipolar stresses on the fluid in which they are immersed. This is relevant to several experimental systems, such as recently studied tripartite rods that create extensile flows by consuming a chemical fuel. We first describe the system through a Doi-Onsager kinetic theory based on microscopic modeling. This theory captures the active stresses produced by the particles that can drive hydrodynamic instabilities, as well as the steric interactions of rodlike particles that lead to nematic alignment. This active nematic system yields complex flows and disclination defect dynamics very similar to phenomenological Landau-deGennes Q -tensor theories for active nematic fluids, as well as by more complex Doi-Onsager theories for polar microtubule-motor-protein systems. We apply the quasiequilibrium Bingham closure, used to study suspensions of passive microscopic rods, to develop a nonstandard Q -tensor theory. We demonstrate through simulation that this B Q -tensor theory gives an excellent analytical and statistical accounting of the suspension's complex dynamics, at a far reduced computational cost. Finally, we apply the B Q -tensor model to study the dynamics of extensor suspensions in circular and biconcave domains. In circular domains, we reproduce previous results for systems with weak nematic alignment, but for strong alignment we find unusual dynamics with activity-controlled defect production and absorption at the boundaries of the domain. In biconcave domains, a Fredericks-like transition occurs as the width of the neck connecting the two disks is varied.

  17. Kernel Manifold Alignment for Domain Adaptation.

    PubMed

    Tuia, Devis; Camps-Valls, Gustau

    2016-01-01

    The wealth of sensory data coming from different modalities has opened numerous opportunities for data analysis. The data are of increasing volume, complexity and dimensionality, thus calling for new methodological innovations towards multimodal data processing. However, multimodal architectures must rely on models able to adapt to changes in the data distribution. Differences in the density functions can be due to changes in acquisition conditions (pose, illumination), sensors characteristics (number of channels, resolution) or different views (e.g. street level vs. aerial views of a same building). We call these different acquisition modes domains, and refer to the adaptation problem as domain adaptation. In this paper, instead of adapting the trained models themselves, we alternatively focus on finding mappings of the data sources into a common, semantically meaningful, representation domain. This field of manifold alignment extends traditional techniques in statistics such as canonical correlation analysis (CCA) to deal with nonlinear adaptation and possibly non-corresponding data pairs between the domains. We introduce a kernel method for manifold alignment (KEMA) that can match an arbitrary number of data sources without needing corresponding pairs, just few labeled examples in all domains. KEMA has interesting properties: 1) it generalizes other manifold alignment methods, 2) it can align manifolds of very different complexities, performing a discriminative alignment preserving each manifold inner structure, 3) it can define a domain-specific metric to cope with multimodal specificities, 4) it can align data spaces of different dimensionality, 5) it is robust to strong nonlinear feature deformations, and 6) it is closed-form invertible, which allows transfer across-domains and data synthesis. To authors' knowledge this is the first method addressing all these important issues at once. We also present a reduced-rank version of KEMA for computational efficiency, and discuss the generalization performance of KEMA under Rademacher principles of stability. Aligning multimodal data with KEMA reports outstanding benefits when used as a data pre-conditioner step in the standard data analysis processing chain. KEMA exhibits very good performance over competing methods in synthetic controlled examples, visual object recognition and recognition of facial expressions tasks. KEMA is especially well-suited to deal with high-dimensional problems, such as images and videos, and under complicated distortions, twists and warpings of the data manifolds. A fully functional toolbox is available at https://github.com/dtuia/KEMA.git.

  18. Fnip1 regulates skeletal muscle fiber type specification, fatigue resistance, and susceptibility to muscular dystrophy

    PubMed Central

    Reyes, Nicholas L.; Banks, Glen B.; Tsang, Mark; Margineantu, Daciana; Gu, Haiwei; Djukovic, Danijel; Chan, Jacky; Torres, Michelle; Liggitt, H. Denny; Hirenallur-S, Dinesh K.; Hockenbery, David M.; Raftery, Daniel; Iritani, Brian M.

    2015-01-01

    Mammalian skeletal muscle is broadly characterized by the presence of two distinct categories of muscle fibers called type I “red” slow twitch and type II “white” fast twitch, which display marked differences in contraction strength, metabolic strategies, and susceptibility to fatigue. The relative representation of each fiber type can have major influences on susceptibility to obesity, diabetes, and muscular dystrophies. However, the molecular factors controlling fiber type specification remain incompletely defined. In this study, we describe the control of fiber type specification and susceptibility to metabolic disease by folliculin interacting protein-1 (Fnip1). Using Fnip1 null mice, we found that loss of Fnip1 increased the representation of type I fibers characterized by increased myoglobin, slow twitch markers [myosin heavy chain 7 (MyH7), succinate dehydrogenase, troponin I 1, troponin C1, troponin T1], capillary density, and mitochondria number. Cultured Fnip1-null muscle fibers had higher oxidative capacity, and isolated Fnip1-null skeletal muscles were more resistant to postcontraction fatigue relative to WT skeletal muscles. Biochemical analyses revealed increased activation of the metabolic sensor AMP kinase (AMPK), and increased expression of the AMPK-target and transcriptional coactivator PGC1α in Fnip1 null skeletal muscle. Genetic disruption of PGC1α rescued normal levels of type I fiber markers MyH7 and myoglobin in Fnip1-null mice. Remarkably, loss of Fnip1 profoundly mitigated muscle damage in a murine model of Duchenne muscular dystrophy. These results indicate that Fnip1 controls skeletal muscle fiber type specification and warrant further study to determine whether inhibition of Fnip1 has therapeutic potential in muscular dystrophy diseases. PMID:25548157

  19. Investigations into the Sarcomeric Protein and Ca2+-Regulation Abnormalities Underlying Hypertrophic Cardiomyopathy in Cats (Felix catus)

    PubMed Central

    Messer, Andrew E.; Chan, Jasmine; Daley, Alex; Copeland, O'Neal; Marston, Steven B.; Connolly, David J.

    2017-01-01

    Hypertrophic cardiomyopathy (HCM) is the most common single gene inherited cardiomyopathy. In cats (Felix catus) HCM is even more prevalent and affects 16% of the outbred population and up to 26% in pedigree breeds such as Maine Coon and Ragdoll. Homozygous MYBPC3 mutations have been identified in these breeds but the mutations in other cats are unknown. At the clinical and physiological level feline HCM is closely analogous to human HCM but little is known about the primary causative mechanism. Most identified HCM causing mutations are in the genes coding for proteins of the sarcomere. We therefore investigated contractile and regulatory proteins in left ventricular tissue from 25 cats, 18 diagnosed with HCM, including a Ragdoll cat with a homozygous MYBPC3 R820W, and 7 non-HCM cats in comparison with human HCM (from septal myectomy) and donor heart tissue. Myofibrillar protein expression was normal except that we observed 20–44% MyBP-C haploinsufficiency in 5 of the HCM cats. Troponin extracted from 8 HCM and 5 non-HCM cat hearts was incorporated into thin filaments and studied by in vitro motility assay. All HCM cat hearts had a higher (2.06 ± 0.13 fold) Ca2+-sensitivity than non-HCM cats and, in all the HCM cats, Ca2+-sensitivity was not modulated by troponin I phosphorylation. We were able to restore modulation of Ca2+-sensitivity by replacing troponin T with wild-type protein or by adding 100 μM Epigallocatechin 3-gallate (EGCG). These fundamental regulatory characteristics closely mimic those seen in human HCM indicating a common molecular mechanism that is independent of the causative mutation. Thus, the HCM cat is a potentially useful large animal model. PMID:28642712

  20. AMP-activated Protein Kinase Phosphorylates Cardiac Troponin I at Ser-150 to Increase Myofilament Calcium Sensitivity and Blunt PKA-dependent Function*

    PubMed Central

    Nixon, Benjamin R.; Thawornkaiwong, Ariyoporn; Jin, Janel; Brundage, Elizabeth A.; Little, Sean C.; Davis, Jonathan P.; Solaro, R. John; Biesiadecki, Brandon J.

    2012-01-01

    AMP-activated protein kinase (AMPK) is an energy-sensing enzyme central to the regulation of metabolic homeostasis. In the heart AMPK is activated during cardiac stress-induced ATP depletion and functions to stimulate metabolic pathways that restore the AMP/ATP balance. Recently it was demonstrated that AMPK phosphorylates cardiac troponin I (cTnI) at Ser-150 in vitro. We sought to determine if the metabolic regulatory kinase AMPK phosphorylates cTnI at Ser-150 in vivo to alter cardiac contractile function directly at the level of the myofilament. Rabbit cardiac myofibrils separated by two-dimensional isoelectric focusing subjected to a Western blot with a cTnI phosphorylation-specific antibody demonstrates that cTnI is endogenously phosphorylated at Ser-150 in the heart. Treatment of myofibrils with the AMPK holoenzyme increased cTnI Ser-150 phosphorylation within the constraints of the muscle lattice. Compared with controls, cardiac fiber bundles exchanged with troponin containing cTnI pseudo-phosphorylated at Ser-150 demonstrate increased sensitivity of calcium-dependent force development, blunting of both PKA-dependent calcium desensitization, and PKA-dependent increases in length dependent activation. Thus, in addition to the defined role of AMPK as a cardiac metabolic energy gauge, these data demonstrate AMPK Ser-150 phosphorylation of cTnI directly links the regulation of cardiac metabolic demand to myofilament contractile energetics. Furthermore, the blunting effect of cTnI Ser-150 phosphorylation cross-talk can uncouple the effects of myofilament PKA-dependent phosphorylation from β-adrenergic signaling as a novel thin filament contractile regulatory signaling mechanism. PMID:22493448

  1. Biomarkers in Trypanosoma cruzi-infected and uninfected individuals with varying severity of cardiomyopathy in Santa Cruz, Bolivia.

    PubMed

    Okamoto, Emi E; Sherbuk, Jacqueline E; Clark, Eva H; Marks, Morgan A; Gandarilla, Omar; Galdos-Cardenas, Gerson; Vasquez-Villar, Angel; Choi, Jeong; Crawford, Thomas C; Do, Rose Q; Q, Rose; Fernandez, Antonio B; Colanzi, Rony; Flores-Franco, Jorge Luis; Gilman, Robert H; Bern, Caryn

    2014-10-01

    Twenty to thirty percent of persons with Trypanosoma cruzi infection eventually develop cardiomyopathy. If an early indicator were to be identified and validated in longitudinal studies, this could enable treatment to be prioritized for those at highest risk. We evaluated cardiac and extracellular matrix remodeling markers across cardiac stages in T. cruzi infected (Tc+) and uninfected (Tc-) individuals. Participants were recruited in a public hospital in Santa Cruz, Bolivia and assigned cardiac severity stages by electrocardiogram and echocardiogram. BNP, NTproBNP, CKMB, troponin I, MMP-2, MMP-9, TIMP-1, TIMP-2, TGFb1, and TGFb2 were measured in specimens from 265 individuals using multiplex bead systems. Biomarker levels were compared between Tc+ and Tc- groups, and across cardiac stages. Receivers operating characteristic (ROC) curves were created; for markers with area under curve>0.60, logistic regression was performed. Analyses stratified by cardiac stage showed no significant differences in biomarker levels by Tc infection status. Among Tc+ individuals, those with cardiac insufficiency had higher levels of BNP, NTproBNP, troponin I, MMP-2, TIMP-1, and TIMP-2 than those with normal ejection fraction and left ventricular diameter. No individual marker distinguished between the two earliest Tc+ stages, but in ROC-based analyses, MMP-2/MMP-9 ratio was significantly higher in those with than those without ECG abnormalities. BNP, NTproBNP, troponin I, MMP-2, TIMP-1, and TIMP-2 levels rose with increasing severity stage but did not distinguish between Chagas cardiomyopathy and other cardiomyopathies. Among Tc+ individuals without cardiac insufficiency, only the MMP-2/MMP-9 ratio differed between those with and without ECG changes.

  2. Use of observed within-person variation of cardiac troponin in emergency department patients for determination of biological variation and percentage and absolute reference change values.

    PubMed

    Simpson, Aaron J; Potter, Julia M; Koerbin, Gus; Oakman, Carmen; Cullen, Louise; Wilkes, Garry J; Scanlan, Samuel L; Parsonage, William; Hickman, Peter E

    2014-06-01

    Many patients presenting to the emergency department (ED) for assessment of possible acute coronary syndrome (ACS) have low cardiac troponin concentrations that change very little on repeat blood draw. It is unclear if a lack of change in cardiac troponin concentration can be used to identify acutely presenting patients at low risk of ACS. We used the hs-cTnI assay from Abbott Diagnostics, which can detect cTnI in the blood of nearly all people. We identified a population of ED patients being assessed for ACS with repeat cTnI measurement who ultimately were proven to have no acute cardiac disease at the time of presentation. We used data from the repeat sampling to calculate total within-person CV (CV(T)) and, knowing the assay analytical CV (CV(A)), we could calculate within-person biological variation (CV(i)), reference change values (RCVs), and absolute RCV delta cTnI concentrations. We had data sets on 283 patients. Men and women had similar CV(i) values of approximately 14%, which was similar at all concentrations <40 ng/L. The biological variation was not dependent on the time interval between sample collections (t = 1.5-17 h). The absolute delta critical reference change value was similar no matter what the initial cTnI concentration was. More than 90% of subjects had a critical reference change value <5 ng/L, and 97% had values of <10 ng/L. With this hs-cTnI assay, delta cTnI seems to be a useful tool for rapidly identifying ED patients at low risk for possible ACS. © 2014 The American Association for Clinical Chemistry.

  3. Comparison of cardiac TnI outliers using a contemporary and a high-sensitivity assay on the Abbott Architect platform.

    PubMed

    Ryan, J B; Southby, S J; Stuart, L A; Mackay, R; Florkowski, C M; George, P M

    2014-07-01

    Assays for cardiac troponin (cTn) have undergone improvements in sensitivity and precision in recent years. Increased rates of outliers, however, have been reported on various cTn platforms, typically giving irreproducible, falsely higher results. We aimed to evaluate the outlier rate occurring in patients with elevated cTnI using a contemporary and high-sensitivity assay. All patients with elevated cTnI (up to 300 ng/L) performed over a 21-month period were assayed in duplicate. A contemporary assay (Abbott STAT Troponin-I) was used for the first part of the study and subsequently a high-sensitivity assay (Abbott STAT High-Sensitive Troponin-I) was used. Outliers exceeded a calculated critical difference (CD) (CD = z × √2 × SDAnalytical) where z = 3.5 (for probability of 0.0005) and critical outliers also were on a different side of the decision level. The respective outlier and critical outlier rates were 0.22% and 0.10% for the contemporary assay (n = 4009) and 0.18% and 0.13% for the high-sensitivity assay (n = 3878). There was no significant reduction in outlier rate between the two assays (χ(2) = 0.034, P = 0.854). Fifty-six percent of outliers occurred in samples where cTn was an 'add-on' test (and was stored and refrigerated prior to assay). Despite recent improvements in cTn methods, outliers (including critical outliers) still occur at a low rate in both a contemporary and high-sensitivity cTnI assay. Laboratory and clinical staff should be aware of this potential analytical error, particularly in samples with suboptimal sample handling such as add-on tests. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. Diagnosis and management of ischemic heart disease.

    PubMed

    Lippi, Giuseppe; Franchini, Massimo; Cervellin, Gianfranco

    2013-03-01

    Ischemic heart disease (IHD) is the leading cause of death and disability worldwide. An early and accurate diagnosis of IHD is necessary to improve outcomes. According to recent guidelines, the diagnosis of acute myocardial infarction (AMI) is based on increased or decreased value of cardiospecific troponins with one measure exceeding the 99th percentile upper reference limit, associated with symptoms suggestive for myocardial ischemia, indicative electrocardiogram abnormalities, and evidence of recent myocardial functional impairment or intracoronary thrombosis. The recent advent of highly sensitive troponin immunoassays has represented a paradigm shift, wherein the improved analytical sensitivity has increased the negative predictive value, while contextually decreasing the diagnostic specificity of these tests. Although several additional biomarkers have been proposed as surrogate or in combination with troponins, there is little evidence that any of these will substantially improve AMI diagnosis. With regard to therapy, early mechanical (i.e., percutaneous coronary intervention, PCI) or pharmacological reperfusion should be performed early in ST-segment elevation myocardial infarction (STEMI) within 12 h of symptom onset, whereas fibrinolysis may be considered in all other circumstances. Patients undergoing primary PCI should also receive a combination of double antiplatelet therapy (i.e., aspirin and adenosine diphosphate receptor blocker), associated with parenteral anticoagulation, preferably with low-molecular-weight heparin. In analogy with STEMI, a wealth of data shows that primary early invasive strategy (i.e., PCI) and antiplatelet therapy remains the cornerstone of management of patients with non-ST segment elevation acute coronary syndrome. Stem cell-based therapy has also emerged as a potentially therapeutic option, and there are ongoing efforts among several investigators to translate basic research into clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Fast pressure jumps can perturb calcium and magnesium binding to troponin C F29W.

    PubMed

    Pearson, David S; Swartz, Darl R; Geeves, Michael A

    2008-11-18

    We have used rapid pressure jump and stopped-flow fluorometry to investigate calcium and magnesium binding to F29W chicken skeletal troponin C. Increased pressure perturbed calcium binding to the N-terminal sites in the presence and absence of magnesium and provided an estimate for the volume change upon calcium binding (-12 mL/mol). We observed a biphasic response to a pressure change which was characterized by fast and slow reciprocal relaxation times of the order 1000/s and 100/s. Between pCa 8-5.4 and at troponin C concentrations of 8-28 muM, the slow relaxation times were invariant, indicating that a protein isomerization was rate-limiting. The fast event was only detected over a very narrow pCa range (5.6-5.4). We have devised a model based on a Monod-Wyman-Changeux cooperative mechanism with volume changes of -9 and +6 mL/mol for the calcium binding to the regulatory sites and closed to open protein isomerization steps, respectively. In the absence of magnesium, we discovered that calcium binding to the C-terminal sites could be detected, despite their position distal to the calcium-sensitive tryptophan, with a volume change of +25 mL/mol. We used this novel observation to measure competitive magnesium binding to the C-terminal sites and deduced an affinity in the range 200-300 muM (and a volume change of +35 mL/mol). This affinity is an order of magnitude tighter than equilibrium fluorescence data suggest based on a model of direct competitive binding. Magnesium thus indirectly modulates binding to the N-terminal sites, which may act as a fine-tuning mechanism in vivo.

  6. Fast Pressure Jumps Can Perturb Calcium and Magnesium Binding to Troponin C F29W

    PubMed Central

    Pearson, David S.; Swartz, Darl R.; Geeves, Michael A.

    2009-01-01

    We have used rapid pressure jump and stopped-flow fluorimetry to investigate calcium and magnesium binding to F29W chicken skeletal troponin C. Increased pressure perturbed calcium binding to the N-terminal sites in the presence and absence of magnesium and provided an estimate for the volume change upon calcium binding (-12 mL.mol-1). We observed a biphasic response to a pressure change which was characterized by fast and slow reciprocal relaxation times of the order 1000 s-1 and 100 s-1. Between pCa 8-5.4 and at troponin C concentrations of 8-28 μM, the slow relaxation times were invariant indicating that a protein isomerization was rate-limiting. The fast event was only detected over a very narrow pCa range (5.6-5.4). We have devised a model based on a Monod-Wyman-Changeux cooperative mechanism with volume changes of -9 and +6 mL/mol for the calcium binding to the regulatory sites and closed to open protein isomerization steps respectively. In the absence of magnesium, we discovered that calcium binding to the C-terminal sites could be detected, despite their position distal to the calcium sensitive tryptophan, with a volume change of +25 mL/mol. We used this novel observation to measure competitive magnesium binding to the C-terminal sites and deduced an affinity in the range 200 - 300 μM (and a volume change of +35 mL/mol). This affinity is an order of magnitude tighter than equilibrium fluorescence data suggest based on a model of direct competitive binding. Magnesium thus indirectly modulates binding to the N-terminal sites, which may act as a fine-tuning mechanism in vivo. PMID:18942859

  7. Myocardial Injury after Percutaneous Coronary Intervention for In-Stent Restenosis Versus de novo Stenosis.

    PubMed

    Shimonaga, Takashi; Kurisu, Satoshi; Watanabe, Noriaki; Ikenaga, Hiroki; Higaki, Tadanao; Iwasaki, Toshitaka; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2015-01-01

    Periprocedural myocardial injury (PMI) remains a relatively common complication even after successful procedures. In-stent restenosis (ISR) may be involved in lesion-related factors for PMI. We compared the incidence of PMI between patients with ISR and those with de novo stenosis. The study population consisted of 121 patients with coronary artery disease who had been treated with statins and subsequently underwent angiographically successful percutaneous coronary intervention (PCI). Blood samples for troponin I were collected 18 to 24 hours after PCI. PMI was defined as an increase in the troponin I levels greater than 0.15 ng/mL. Major PMI was defined as an increase in the troponin I levels greater than 0.75 ng/mL. There were 34 patients with ISR and 87 patients with de novo stenosis. The incidence of PMI was similar between the two groups (47.1 % vs. 55.2 %, p=0.42). Among the patients with ISR, the incidences of PMI were 33.3 %, 60.0 % and 66.7 % in patients with focal ISR, diffuse ISR and diffuse proliferative ISR, respectively, although these differences were not statistically significant. The incidence of major PMI was significantly less frequent in patients with ISR than those with de novo stenosis (5.9 % vs. 25.3 %, p=0.03). A multivariate logistic regression analysis showed that ISR [odds ratio (OR) 0.22, 95% confidence interval (CI) 0.03-0.90; p=0.03] and the maximum inflation pressure (OR 1.15, 95% CI 1.04-1.30; p=0.009) were independent predictors of major PMI. Our results suggest that while PMI occurs in patients with ISR as commonly as those with de novo stenosis, major PMI occurs less frequently in patients with ISR.

  8. Impact of Modifiable Risk Factors on B-type Natriuretic Peptide and Cardiac Troponin T Concentrations

    PubMed Central

    Srivastava, Pratyaksh K.; Pradhan, Aruna D.; Cook, Nancy R.; Ridker, Paul M.; Everett, Brendan M.

    2015-01-01

    Alcohol use, physical activity, diet, and cigarette smoking are modifiable cardiovascular risk factors that have a substantial impact on the risk of myocardial infarction, stroke, and cardiovascular death. We hypothesized that these behaviors may alter concentrations of cardiac troponin, a marker of myocyte injury, and B-type natriuretic peptide, a marker of myocyte stress. Both markers have shown strong association with adverse cardiovascular outcomes. In 519 women with no evidence of cardiovascular disease, we measured circulating concentrations of cardiac troponin T, using a high-sensitivity assay (hsTnT), and the amino-terminal fragment of B-type natriuretic peptide (NT-proBNP). We used logistic regression to determine if these behaviors were associated with detectable hsTnT (>3 ng/L) or with NT-proBNP in the highest quartile (≥127.3 ng/L). The median (Q1-Q3) NT-proBNP of the cohort was 68.8 (40.3–127.3), and 30.8% (160/519) of the cohort had detectable circulating hsTnT. In adjusted models, women who drank 1–6 drinks per week had lower odds of having a detectable hsTnT (0.58, 95% CI: 0.34–0.96) and lower odds of having an elevated NT-proBNP (OR 0.55, 95% CI 0.32–0.96). We were subsequently able to validate the results for B-type natriuretic peptide in a large independent cohort. In conclusion, our results suggest that regular alcohol consumption is associated with lower concentrations of hsTnT and NT-proBNP, two cardiovascular biomarkers associated with cardiovascular risk, and raise the hypothesis that the beneficial effects of alcohol consumption may be mediated by direct effects on the myocardium. PMID:26739393

  9. Biomarkers in Trypanosoma cruzi-Infected and Uninfected Individuals with Varying Severity of Cardiomyopathy in Santa Cruz, Bolivia

    PubMed Central

    Clark, Eva H.; Marks, Morgan A.; Gandarilla, Omar; Galdos-Cardenas, Gerson; Vasquez-Villar, Angel; Choi, Jeong; Crawford, Thomas C.; Q., Rose; Fernandez, Antonio B.; Colanzi, Rony; Flores-Franco, Jorge Luis; Gilman, Robert H.; Bern, Caryn

    2014-01-01

    Background Twenty to thirty percent of persons with Trypanosoma cruzi infection eventually develop cardiomyopathy. If an early indicator were to be identified and validated in longitudinal studies, this could enable treatment to be prioritized for those at highest risk. We evaluated cardiac and extracellular matrix remodeling markers across cardiac stages in T. cruzi infected (Tc+) and uninfected (Tc−) individuals. Methods Participants were recruited in a public hospital in Santa Cruz, Bolivia and assigned cardiac severity stages by electrocardiogram and echocardiogram. BNP, NTproBNP, CKMB, troponin I, MMP-2, MMP-9, TIMP-1, TIMP-2, TGFb1, and TGFb2 were measured in specimens from 265 individuals using multiplex bead systems. Biomarker levels were compared between Tc+ and Tc− groups, and across cardiac stages. Receivers operating characteristic (ROC) curves were created; for markers with area under curve>0.60, logistic regression was performed. Results Analyses stratified by cardiac stage showed no significant differences in biomarker levels by Tc infection status. Among Tc+ individuals, those with cardiac insufficiency had higher levels of BNP, NTproBNP, troponin I, MMP-2, TIMP-1, and TIMP-2 than those with normal ejection fraction and left ventricular diameter. No individual marker distinguished between the two earliest Tc+ stages, but in ROC-based analyses, MMP-2/MMP-9 ratio was significantly higher in those with than those without ECG abnormalities. Conclusions BNP, NTproBNP, troponin I, MMP-2, TIMP-1, and TIMP-2 levels rose with increasing severity stage but did not distinguish between Chagas cardiomyopathy and other cardiomyopathies. Among Tc+ individuals without cardiac insufficiency, only the MMP-2/MMP-9 ratio differed between those with and without ECG changes. PMID:25275382

  10. Effects of anthracycline, cyclophosphamide and taxane chemotherapy on QTc measurements in patients with breast cancer.

    PubMed

    Veronese, Pedro; Hachul, Denise Tessariol; Scanavacca, Mauricio Ibrahim; Hajjar, Ludhmila Abrahão; Wu, Tan Chen; Sacilotto, Luciana; Veronese, Carolina; Darrieux, Francisco Carlos da Costa

    2018-01-01

    Acute and subacute cardiotoxicity are characterized by prolongation of the corrected QT interval (QTc) and other measures derived from the QTc interval, such as QTc dispersion (QTdc) and transmural dispersion of repolarization (DTpTe). Although anthracyclines prolong the QTc interval, it is unclear whether breast cancer patients who undergo the ACT chemotherapy regimen of anthracycline (doxorubicin: A), cyclophosphamide (C) and taxane (T) may present with QTc, QTdc and DTpTe prolongation. Twenty-three consecutive patients with breast cancer were followed prospectively during ACT chemotherapy and were analyzed according to their QT measurements. QTc, QTdc and DTpTe measurements were determined by a 12-lead electrocardiogram (EKG) prior to chemotherapy (baseline), immediately after the first phase of anthracycline and cyclophosphamide (AC) treatment, and immediately after T treatment. Serum troponin and B-type natriuretic peptide (BNP) levels were also measured. Compared to baseline values, the QTc interval was significantly prolonged after the AC phase (439.7 ± 33.2 ms vs. 472.5 ± 36.3 ms, p = 0.001) and after T treatment (439.7 ± 33.2 ms vs. 467.9 ± 42.6 ms, p < 0.001). Troponin levels were elevated after the AC phase (23.0 pg/mL [min-max: 6.0-85.0] vs. 6.0 pg/mL [min-max: 6.0-22.0], p < 0.001) and after T treatment (25.0 pg/mL [min-max: 6.0-80.0] vs. 6.0 pg/mL [min-max: 6.0-22.0], p < 0.001) compared to baseline values. In this prospective study of patients with non-metastatic breast cancer who underwent ACT chemotherapy, significant QTc prolongation and an elevation in serum troponin levels were observed.

  11. Improved fatigue resistance in Gsα-deficient and aging mouse skeletal muscles due to adaptive increases in slow fibers

    PubMed Central

    Feng, Han-Zhong; Chen, Min; Weinstein, Lee S.

    2011-01-01

    Genetically modified mice with deficiency of the G protein α-subunit (Gsα) in skeletal muscle showed metabolic abnormality with reduced glucose tolerance, low muscle mass, and low contractile force, along with a fast-to-slow-fiber-type switch (Chen M, Feng HZ, Gupta D, Kelleher J, Dickerson KE, Wang J, Hunt D, Jou W, Gavrilova O, Jin JP, Weinstein LS. Am J Physiol Cell Physiol 296: C930–C940, 2009). Here we investigated a hypothesis that the switching to more slow fibers is an adaptive response with specific benefit. The results showed that, corresponding to the switch of myosin isoforms, the thin-filament regulatory proteins troponin T and troponin I both switched to their slow isoforms in the atrophic soleus muscle of 3-mo-old Gsα-deficient mice. This fiber-type switch involving coordinated changes of both thick- and thin-myofilament proteins progressed in the Gsα-deficient soleus muscles of 18- to 24-mo-old mice, as reflected by the expression of solely slow isoforms of myosin and troponin. Compared with age-matched controls, Gsα-deficient soleus muscles with higher proportion of slow fibers exhibited slower contractile and relaxation kinetics and lower developed force, but significantly increased resistance to fatigue, followed by a better recovery. Gsα-deficient soleus muscles of neonatal and 3-wk-old mice did not show the increase in slow fibers. Therefore, the fast-to-slow-fiber-type switch in Gsα deficiency at older ages was likely an adaptive response. The benefit of higher fatigue resistance in adaption to metabolic deficiency and aging provides a mechanism to sustain skeletal muscle function in diabetic patients and elderly individuals. PMID:21680879

  12. [Cardiac safety of electroconvulsive therapy in an elderly patient--a case report].

    PubMed

    Karakuła-Juchnowicz, Hanna; Próchnicki, Michał; Kiciński, Paweł; Olajossy, Marcin; Pelczarska-Jamroga, Agnieszka; Dzikowski, Michał; Jaroszyński, Andrzej

    2015-10-01

    Since electroconvulsive therapy (ECT) was introduced as treatment for psychiatric disorders in 1938, it has remained one of the most effective therapeutic methods. ECT is often used as a "treatment of last resort" when other methods fail, and a life-saving procedure in acute clinical states when a rapid therapeutic effect is needed. Mortality associated with ECT is lower, compared to the treatment with tricyclic antidepressants, and comparable to that observed in so-called minor surgery. In the literature, cases of effective and safe electroconvulsive therapy have been described in patients of advanced age, with a burden of many somatic disorders. However, cases of acute cardiac episodes have also been reported during ECT. The qualification of patients for ECT and the selection of a group of patients at the highest risk of cardiovascular complications remains a serious clinical problem. An assessment of the predictive value of parameters of standard electrocardiogram (ECG), which is a simple, cheap and easily available procedure, deserves special attention. This paper reports a case of a 74-year-old male patient treated with ECT for a severe depressive episode, in the context of cardiologic safety. Both every single ECT session and the full course were assessed to examine their impact on levels of troponin T, which is a basic marker of cardiac damage, and selected ECG parameters (QTc, QRS). In the presented case ECT demonstrated its high general and cardiac safety with no negative effect on cardiac troponin (TnT) levels, corrected QT interval (QTc) duration, or other measured ECG parameters despite initially increased troponin levels, the patient's advanced age, the burden of a severe somatic disease and its treatment (anticancer therapy). © 2015 MEDPRESS.

  13. Effect of obstructive sleep apnoea on severity and short-term prognosis of acute coronary syndrome.

    PubMed

    Barbé, Ferran; Sánchez-de-la-Torre, Alicia; Abad, Jorge; Durán-Cantolla, Joaquin; Mediano, Olga; Amilibia, Jose; Masdeu, Maria José; Florés, Marina; Barceló, Antonia; de la Peña, Mónica; Aldomá, Albina; Worner, Fernando; Valls, Joan; Castellà, Gerard; Sánchez-de-la-Torre, Manuel

    2015-02-01

    The goal of this study was to evaluate the influence of obstructive sleep apnoea on the severity and short-term prognosis of patients admitted for acute coronary syndrome. Obstructive sleep apnoea was defined as an apnoea-hypopnoea index (AHI) >15 h(-1). We evaluated the acute coronary syndrome severity (ejection fraction, Killip class, number of diseased vessels, and plasma peak troponin) and short-term prognosis (length of hospitalisation, complications and mortality). We included 213 patients with obstructive sleep apnoea (mean±sd AHI 30±14 h(-1), 61±10 years, 80% males) and 218 controls (AHI 6±4 h(-1), 57±12 years, 82% males). Patients with obstructive sleep apnoea exhibited a higher prevalence of systemic hypertension (55% versus 37%, p<0.001), higher body mass index (29±4 kg·m(-2) versus 26±4 kg·m(-2), p<0.001), and lower percentage of smokers (61% versus 71%, p=0.04). After adjusting for smoking, age, body mass index and hypertension, the plasma peak troponin levels were significantly elevated in the obstructive sleep apnoea group (831±908 ng·L(-1) versus 987±884 ng·L(-1), p=0.03) and higher AHI severity was associated with an increased number of diseased vessels (p=0.04). The mean length of stay in the coronary care unit was higher in the obstructive sleep apnoea group (p=0.03). This study indicates that obstructive sleep apnoea is related to an increase in the peak plasma troponin levels, number of diseased vessels, and length of stay in the coronary care unit. Copyright ©ERS 2015.

  14. Temporal seizure focus and status epilepticus are associated with high-sensitive troponin I elevation after epileptic seizures.

    PubMed

    Chatzikonstantinou, Anastasios; Ebert, Anne D; Hennerici, Michael G

    2015-09-01

    Postictal elevation of high-sensitive troponin I (TNI), a highly specific biomarker for myocardial ischemia, has been reported. We aimed at evaluating its association of high-sensitive troponin I (TNI) with seizure type and focus, as well as vascular risk factors. TNI was measured in 247 patients admitted to our clinic via the emergency room with an acute epileptic seizure. TNI control measurements were performed in 61.5% of cases. All patients underwent electroencephalography and cerebral imaging. Seizure focus - when possible - was determined using results from these examinations as well as clinical data. Of 247 patients, 133 (53.8%) were men, the mean age was 59 ± 18 years. 70 (28.3%) patients had focal and 177 (71.7%) generalized seizures. Status epilepticus was present in 38 cases (15.4%). Mean TNI was 0.05 ± 0.17. TNI was elevated in 27 patients (10.9%). Higher age, status epilepticus and temporal seizure focus were significantly associated with TNI elevation in multivariate analysis. In 21 (13.8%) of the patients with TNI control measurement, TNI was continuously elevated. Higher age and temporal seizure focus were significantly associated with continuously high TNI. Coronary heart disease and vascular risk factors were significantly associated with high TNI only in univariate analysis. No patient had a symptomatic myocardial ischemia. Postictal TNI elevation is relatively common in older patients with status epilepticus or temporal seizure focus. These data support the concept of relevant and possibly dangerous ictal effects on cardiac function especially in temporal lobe seizures. Although the risk of manifest postictal myocardial infarction seems to be very low, selected patients could profit from closer monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Changes in Left Atrial Transport Function in Patients Who Maintained Sinus Rhythm After Successful Radiofrequency Catheter Ablation for Atrial Fibrillation: A 1-Year Follow-Up Multislice Computed Tomography Study.

    PubMed

    Kim, Jin-Seok; Im, Sung Il; Shin, Seung Yong; Kang, Jun Hyuk; Na, Jin Oh; Choi, Cheol Ung; Kim, Seong Hwan; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo; Hwang, Chun; Kim, Young-Hoon; Yong, Hwan Seok; Lim, Hong Euy

    2017-02-01

    Functional remodeling of left atrium (LA) after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) has not been fully elucidated. This study aimed to determine the impact of RFCA on LA transport function in patients who maintained sinus rhythm (SR) after AF ablation. A total of 96 patients (paroxysmal AF [PAF] = 52) who maintained SR during 1 year after AF ablation were enrolled. Multislice computed tomography was performed to determine LA volume (LAV) and LA emptying fraction (LAEF) at pre-RFCA and 1-year post-RFCA. Creatine kinase-MB (CK-MB) and troponin-T levels were analyzed 1-day post-RFCA. At 1-year post-RFCA, mean LAV and LAEF decreased in overall patients. Based on LAEF change (ΔLAEF) cutoff of 5.0%, LAEF reduced in 41 patients (worsened group) and improved or showed no change in 55 patients (preserved group). Compared with preserved group, worsened group had a higher proportion of PAF, higher levels of CK-MB and troponin-T, and additional LA ablation. ΔLAEF was inversely correlated with CK-MB and troponin-T levels. Subgroup analysis showed that LAEF significantly decreased in PAF patients who underwent additional LA ablation. Multivariate analysis revealed that high baseline LAEF and additional LA ablation were independent predictors for worsened LAEF. Although SR was maintained for 1 year after AF ablation, LAEF as well as LAV decreased. The extent of LAEF deterioration was significantly associated with the amount of iatrogenic myocardial damage. Our data indicate that extensive atrial ablation may lead to LA functional deterioration, especially in patients with PAF. © 2016 Wiley Periodicals, Inc.

  16. Validation of an accelerated high-sensitivity troponin T assay protocol in an Australian cohort with chest pain.

    PubMed

    Parsonage, William A; Greenslade, Jaimi H; Hammett, Christopher J; Lamanna, Arvin; Tate, Jillian R; Ungerer, Jacobus P; Chu, Kevin; Than, Martin; Brown, Anthony F T; Cullen, Louise

    2014-02-17

    To validate an accelerated biomarker strategy using a high-sensitivity cardiac troponin T (hs-cTnT) assay for diagnosing acute myocardial infarction (AMI) in patients presenting to the emergency department with chest pain; and to validate this strategy in combination with the National Heart Foundation of Australia/Cardiac Society of Australia and New Zealand risk stratification model. Single-centre, prospective, observational cohort study of 764 adults presenting to a tertiary hospital with symptoms of possible acute coronary syndrome between November 2008 and February 2011. AMI or cardiac death within 24 hours of presentation (primary), and major adverse cardiac events within 30 days (secondary). An elevated hs-cTnT assay result above the 99th percentile at either the 0 h or 2 h time points had sensitivity of 96.4% (95% CI, 87.9%-99.0%), specificity of 82.6% (95% CI, 79.7%-85.2%), negative predictive value of 99.7% (95% CI, 98.8%-99.9%) and positive predictive value of 30.5% (95% CI, 24.2%-37.6%) for diagnosing AMI. Compared with a traditional 6 h cardiac troponin testing strategy, the accelerated strategy led to reclassification of risk in only two patients with adverse cardiac outcomes, with no net effect on appropriate management. In patients presenting with chest pain, an accelerated biomarker strategy using the hs-cTnT assay performed well in the initial diagnosis of AMI. The accelerated strategy was also effective when incorporated into a comprehensive strategy of risk stratification that included clinical and demographic factors. The time saved by this approach could have a major impact on health service delivery. Australian New Zealand Clinical Trials Registry ACTRN12610000053022.

  17. Randomized trial comparing 600- with 300-mg loading dose of clopidogrel in patients with non-ST elevation acute coronary syndrome undergoing percutaneous coronary intervention: results of the Platelet Responsiveness to Aspirin and Clopidogrel and Troponin Increment after Coronary intervention in Acute coronary Lesions (PRACTICAL) Trial.

    PubMed

    Yong, Gerald; Rankin, Jamie; Ferguson, Louise; Thom, Jim; French, John; Brieger, David; Chew, Derek P; Dick, Ron; Eccleston, David; Hockings, Bernard; Walters, Darren; Whelan, Alan; Eikelboom, John W

    2009-01-01

    There is uncertainty about the benefit of a higher loading dose (LD) of clopidogrel in patients with non-ST elevation acute coronary syndrome (NSTEACS) undergoing early percutaneous coronary intervention (PCI). We compared the effects of a 600- versus a 300-mg LD of clopidogrel on inhibition of platelet aggregation, myonecrosis, and clinical outcomes in patients with NSTEACS undergoing an early invasive management strategy. Patients with NSTEACS (n = 256, mean age 63 years, 81.6% elevated troponin) without thienopyridine for at least 7 days were randomized to receive 600- or 300-mg LD of clopidogrel. Percutaneous coronary intervention was performed in 140 patients, with glycoprotein IIb/IIIa inhibitor use in 68.6%. Adenosine diphosphate (ADP)-induced platelet aggregation was measured by optical platelet aggregometry immediately before coronary angiography. Post-PCI myonecrosis was defined as a next-day troponin I greater than 5 times the upper limit of reference range and greater than baseline levels. Clopidogrel 600-mg LD compared with 300-mg LD was associated with significantly reduced ADP-induced platelet aggregation (49.7% vs 55.7% with ADP 20 micromol/L) but did not reduce post-PCI myonecrosis or adverse clinical outcomes to 6 months. There was no association between preprocedural platelet aggregation and outcome. These data confirm a modest incremental antiplatelet effect of a 600-mg clopidogrel LD compared with 300-mg LD but provide no support for a clinical benefit in patients with NSTEACS managed with an early invasive strategy including a high rate (69%) of glycoprotein IIb/IIIa inhibitor use during PCI.

  18. The Importance of H-FABP in Determining the Severity of Carbon Monoxide Poisoning.

    PubMed

    Koylu, Ramazan; Cander, Basar; Dundar, Zerrin Defne; Koylu, Oznur; Akilli, Nazire Belgin; Ivelik, Korhan

    2011-12-01

    In this study, we aimed to investigate the importance of the use of heart-type fatty acid binding protein (H-FABP) in evaluating the myocardial damage in patients admitted to the emergency department with moderate to severe carbon monoxide (CO) poisoning. All patients admitted to the emergency department with severe acute CO intoxication were enrolled the study. The H-FABP and cardiac biomarker levels were assessed at 0, 6th and 24th hours. The patients were divided into groups as those with normal echocardiography findings and with wall motion abnormalities. The differences between the groups for these parameters were compared. The mean age of 80 patients was 32.3 ± 12.9 years old. 42 of them were male. On admission, 29 (36.3%) had elevated serum troponin I levels and 56 (70.0%) had elevated serum H-FABP levels. At 6thhour, 4 (5.0%) of 80 patients had higher serum H-FABP levels and 23 (28.8%) of them had higher serum Troponin I levels than 0 hour. The patients with wall motion abnormality had significantly higher serum H-FABP levels compared to the patients with normal echocardiography findings at 6th and 24th hours (p = 0.001 and 0.009). While the serum COHb and H-FABP levels tended to decrease continuously in time (p < 0.001), the serum troponin I levels increased at 6th hour and then decreased at 24th hour (p = 0.017). The serum H-FABP levels are useful in identifying the myocardial damage in patients admitted to the emergency department with moderate to severe carbon monoxide poisoning at an early phase. Carbon monoxide; Poisoning; H-FABP; Myocardial injury.

  19. A FABP-ulous 'rule out' strategy? Heart fatty acid binding protein and troponin for rapid exclusion of acute myocardial infarction.

    PubMed

    Body, Richard; McDowell, Garry; Carley, Simon; Wibberley, Christopher; Ferguson, Jamie; Mackway-Jones, Kevin

    2011-08-01

    Many Emergency Departments (EDs) utilise 'triple marker' testing with CK-MB, myoglobin and troponin I (cTnI) to exclude acute myocardial infarction (AMI) within hours of presentation. We evaluated the ability of 8 biomarkers to rapidly exclude AMI at the point of presentation and investigated whether 'triple marker' testing represents the optimal multimarker strategy. We recruited patients who presented to the ED with suspected cardiac chest pain occurring within 24 h. Blood was drawn at the time of presentation. Diagnostic value was assessed by calculating the area under the ROC curve (AUC) and a multivariate model was constructed by logistic regression. The primary outcome was a diagnosis of AMI, established by ≥12-h troponin testing in all patients. 705 included patients underwent venepuncture a median of 3.5 h after symptom onset. Heart fatty acid binding protein (H-FABP) had an AUC of 0.86 (95% CI 0.82-0.90), which was significantly higher than any other biomarker including cTnI. While no single biomarker could enable exclusion of AMI, multivariate analysis identified cTnI and H-FABP as the optimal biomarker combination. Combined with clinical risk stratification, this strategy had a sensitivity of 96.9%, specificity of 54.7%, PPV 32.4% and NPV 98.8%. We have derived an algorithm that would enable AMI to be immediately excluded in 315 (44.7%) patients at the cost of missing 6 AMIs per 1000 patients treated. While the risk is likely to be unacceptable for clinical implementation, we have highlighted an area for future development using serial testing and increasingly sensitive assays. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Purification of Cardiomyocytes from Differentiating Pluripotent Stem Cells using Molecular Beacons Targeting Cardiomyocyte-Specific mRNA

    PubMed Central

    Kim, Sangsung; Park, Hun-Jun; Byun, Jaemin; Cho, Kyu-Won; Saafir, Talib; Song, Ming-Ke; Yu, Shan Ping; Wagner, Mary; Bao, Gang; Yoon, Young-Sup

    2013-01-01

    Background While methods for generating cardiomyocytes (CMs) from pluripotent stem cells (PSCs) have been reported, current methods produce heterogeneous mixtures of CMs and non-CM cells. Here, we report an entirely novel system in which PSC-derived CMs are purified by CM-specific molecular beacons (MBs). MBs are nano-scale probes that emit a fluorescence signal when hybridized to target mRNAs. Method and Results Five MBs targeting mRNAs of either cardiac troponin T or myosin heavy chain 6/7 were generated. Among five MBs, a MB targeting myosin heavy chain 6/7 mRNA (MHC1-MB) identified up to 99% of HL-1 CMs, a mouse CM cell line, but < 3% of four non-CM cell types in flow cytometry analysis, indicating that MHC1-MB is specific for identifying CMs. We delivered MHC1-MB into cardiomyogenically differentiated PSCs through nucleofection. The detection rate of CMs was similar to the percentages of cardiac troponin T (TNNT2) or cardiac troponin I (TNNI3)-positive CMs, supporting the specificity of MBs. Finally, MHC1-MB-positive cells were FACS-sorted from mouse and human PSC differentiating cultures and ~97% cells expressed TNNT2- or TNNI3 determined by flow cytometry. These MB-based sorted cells maintained their CM characteristics verified by spontaneous beating, electrophysiologic studies, and expression of cardiac proteins. When transplanted in a myocardial infarction model, MB-based purified CMs improved cardiac function and demonstrated significant engraftment for 4 weeks without forming tumors. Conclusions We developed a novel CM selection system that allows production of highly purified CMs. These purified CMs and this system can be valuable for cell therapy and drug discovery. PMID:23995537

Top