Science.gov

Sample records for alkaline filter elution

  1. Fluid mechanics of DNA double-strand filter elution.

    PubMed Central

    Rudinger, George; Blazek, Ed Robert

    2002-01-01

    Measurement of infrequent DNA double-strand breaks (DSB) in mammalian cells is essential for the understanding of cell damage by ionizing radiation and many DNA-reactive drugs. One of the most important assays for measuring DSB in cellular DNA is filter elution. This study is an attempt to determine whether standard concepts of fluid mechanics can yield a self-consistent model of this process. Major assumptions of the analysis are reptation through a channel formed by surrounding strands, with only strand ends captured by filter pores. Both viscosity and entanglement with surrounding strands are considered to determine the resistance to this motion. One important result is that the average elution time of a strand depends not only on its length, but also on the size distribution of the surrounding strands. This model is consistent with experimental observations, such as the dependence of elution kinetics upon radiation dose, but independence from the size of the DNA sample up to a critical filter loading, and possible overlap of elution times for strands of different length. It indicates how the dependence of elution time on the flow rate could reveal the relative importance of viscous and entanglement resistance, and also predicts the consequences of using different filters. PMID:11751292

  2. Application of alkaline elution, Fast Micromethod and flow cytometry in detection of marine contamination.

    PubMed

    Bihari, Nevenka; Hamer, Bojan; Jaksić, Zeljko; Fafandel, Maja; Micić, Milena; Batel, Renato

    2002-06-01

    DNA damage is an inescapable aspect of life in the biosphere. The presented investigations were an attempt to examine the response of a DNA damage as a biomarker of environmental quality in the mussels Mytilus galloprovincialis sampled at differently contaminated areas of Istrian coast, Northern Adriatic. The investigations were performed in order to get information about the genotoxic risk for marine organisms exposed to mixed environmental pollution, as well as the information about the presence of unknown mixture of genotoxic contaminants in the marine environment. Types of DNA damage detected are alkali-labile sites and single-strand breaks measured by Fast Micromethod, interstrand cross-links and DNA protein cross-links by alkaline filter elution and cell cycle disturbation by flow cytometry. The applicability of all three methods for marine quality control is discussed. PMID:12064444

  3. An automated alkaline elution system: DNA damage induced by 1,2-dibromo-3-chloropropane in vivo and in vitro.

    PubMed

    Brunborg, G; Holme, J A; Søderlund, E J; Omichinski, J G; Dybing, E

    1988-11-01

    An automated alkaline elution system for the detection of DNA damage has been developed. After manual application of samples, which is completed within 5 min, the subsequent supply of liquids, changes in flow rates, and temperature are controlled automatically. The system operates 16 filters and may easily be expanded. The sensitivity of the fluorometric DNA determinations with the Hoechst 33258 dye is increased by using an elution buffer (20 mM Na2EDTA, pH 12.50) with low background fluorescence. DNA is determined using an automated setup similar to the one recently presented by Sterzel et al. (1985, Anal. Biochem. 147, 462-467). The most significant modification is the use of a neutralization buffer which allows variations in the pH of eluted fractions. This change increases the sensitivity of the DNA measurements. The automated alkaline elution system was evaluated using the nematocide 1,2-dibromo-3-chloropropane (DBCP) in a study of its genotoxic effects in the testes and the kidneys. Significant DNA damage was induced in testicular cells by 2.5 microM DBCP (1 h) in vitro and 85 mumol/kg DBCP ip (3 h) in vivo. The damage appeared after short treatment times (10 min in vivo). Variations in the observed DBCP response in vivo were largely due to interanimal variations. The automated alkaline elution system proved to be a sensitive assay also for the detection of DNA damage in kidney nuclei prepared from rats exposed to DBCP. Provided that kidney nuclei from untreated rats, mice, or hamster were kept ice-cold until lysing, 85-100% of their DNA was retained after 16 h of elution, indicating highly intact DNA. Under the same conditions, guinea pig DNA was rapidly degraded unless the nuclei were prepared in a buffer with a higher concentration of Na2EDTA (20 mM). PMID:3239754

  4. Major discrepancies between results obtained with two different methods for evaluating DNA damage: alkaline elution and alkaline unwinding. Possible explanations.

    PubMed

    Taningher, M; Bordone, R; Russo, P; Grilli, S; Santi, L; Parodi, S

    1987-01-01

    The fluorometric assay of DNA alkaline unwinding, developed by Birnboim and Jevcak (Cancer Res 41: 1889-1892, 1981) was applied to rat liver DNA, after treatment in vivo. N-nitrosodimethylamine, for which DNA damage in rat liver has been extensively investigated, was tested as a standard compound. The results were in complete agreement (both in terms of damage and repair) with data from the literature and with our own results obtained with other methods of detecting DNA alkaline fragmentation. Sensitivity was also of the same order of that of usual methods, with the effect of 0.3 mg/Kg of N-nitrosodimethylamine being detectable. Other DNA damaging carcinogens such as 1,2-dimethylhydrazine, 2-naphthylamine and dacarbazine were also correctly detected. Compounds like nitrofurantoin, benzoin and caprolactam, which appeared clearly positive with the alkaline elution technique, but for which genotoxicity and carcinogenicity are doubtful (nitrofurantoin) or most likely negative (benzoin and caprolactam), gave negative results with this method. This is also in agreement with previous results, observed using a different approach to measuring DNA unwinding. On the basis of these and other observations, we suggest that, under certain conditions, the alkaline elution technique is perhaps not only sensitive to DNA breaks but also to changes in chromatin conformation. Unwinding methods could be more specific in the detection of DNA fragmentations. PMID:3674758

  5. AN ALTERNATIVE ELUENT TO BEEF EXTRACT FOR ELUTING POLIOVIRUS FROM ELECTROPOSITIVE FILTERS

    EPA Science Inventory

    Traditional methods for enteric virus removal from waters involve filtering the water through a positively charged filter followed by elution with beef extract, second step concentration by flocculation, and assay in cell culture. Two of the problems associated with this method ...

  6. Megasonic sonication for cost-effective and automatable elution of Cryptosporidium from filters and membranes.

    PubMed

    Kerrouche, Abdelfateh; Desmulliez, Marc P Y; Bridle, Helen

    2015-11-01

    Sample processing is a highly challenging stage in the monitoring of waterborne pathogens. This step is time-consuming, requires highly trained technicians and often results in low recovery rates of pathogens. In the UK but also in other parts of the world, Cryptosporidium is the only pathogen directly tested for in routine operational monitoring. The traditional sampling process involves the filtration of 1000L of water, semi-automated elution of the filters and membranes with recovery rates of about 30-40% typically. This paper explores the use of megasonic sonication in an attempt to increase recovery rates and reduce both the time required for processing and the number of labour-intensive steps. Results demonstrate that megasonic energy assisted elution is equally effective as the traditional manual process in terms of recovery rates. Major advantages are however offered in terms of reduction of the elution volume enabling the current centrifugation stage to be avoided. This saves time, equipment and staff costs and critically removes the step in the process that would be most challenging to automate, paving the way thereby for highly effective automated solutions to pathogens monitoring. PMID:26363087

  7. X-ray induced DNA double strand break production and repair in mammalian cells as measured by neutral filter elution.

    PubMed Central

    Bradley, M O; Kohn, K W

    1979-01-01

    This work presents a neutral filter elution method for detecting DNA double strand breaks in mouse L1210 cells after X-ray. The assay will detect the number of double strand breaks induced by as little as 1000 rad of X-ray. The rate of DNA elution through the filters under neutral conditions increases with X-ray dose. Certain conditions for deproteinization, pH, and filter type are shown to increase the assay's sensitivity. Hydrogen peroxide and Bleomycin also induce apparent DNA double strand breaks, although the ratios of double to single strand breaks vary from those produced by X-ray. The introduction of double strand cuts by HpA I restriction endonuclease in DNA lysed on filters results in a rapid rate of elution under neutral conditions, implying that the method can detect double strand breaks if they exist in the DNA. The eluted DNA bands with a double stranded DNA marker in cesium chloride. This evidence suggests that the assay detects DNA double strand breaks. L1210 cells are shown to rejoin most of the DNA double strand breaks induced by 5-10 krad of X-ray with a half-time of about 40 minutes. PMID:92010

  8. Combined DNA extraction and antibody elution from filter papers for the assessment of malaria transmission intensity in epidemiological studies

    PubMed Central

    2013-01-01

    Background Informing and evaluating malaria control efforts relies on knowledge of local transmission dynamics. Serological and molecular tools have demonstrated great sensitivity to quantify transmission intensity in low endemic settings where the sensitivity of traditional methods is limited. Filter paper blood spots are commonly used a source of both DNA and antibodies. To enhance the operational practicability of malaria surveys, a method is presented for combined DNA extraction and antibody elution. Methods Filter paper blood spots were collected as part of a large cross-sectional survey in the Kenyan highlands. DNA was extracted using a saponin/chelex method. The eluate of the first wash during the DNA extraction process was used for antibody detection and compared with previously validated antibody elution procedures. Antibody elution efficiency was assessed by total IgG ELISA for malaria antigens apical membrane antigen-1 (AMA-1) and merozoite-surface protein-1 (MSP-142). The sensitivity of nested 18S rRNA and cytochrome b PCR assays and the impact of doubling filter paper material for PCR sensitivity were determined. The distribution of cell material and antibodies throughout filter paper blood spots were examined using luminescent and fluorescent reporter assays. Results Antibody levels measured after the combined antibody/DNA extraction technique were strongly correlated to those measured after standard antibody elution (p < 0.0001). Antibody levels for both AMA-1 and MSP-142 were generally slightly lower (11.3-21.4%) but age-seroprevalence patterns were indistinguishable. The proportion of parasite positive samples ranged from 12.9% to 19.2% in the different PCR assays. Despite strong agreement between outcomes of different PCR assays, none of the assays detected all parasite-positive individuals. For all assays doubling filter paper material for DNA extraction increased sensitivity. The concentration of cell and antibody material was not

  9. The development of point-of-use water filters as sampling devices in bioforensics: extent of microbial sorption and elution.

    PubMed

    Sedillo, Jennifer L; Quintana, Ayshea; Souza, Kathryn; Oshima, Kevin H; Smith, Geoffrey B

    2008-06-01

    The foundational idea for this project is that household faucet-mounted water filters may be used as bioforensic sampling devices to detect the extent of a potential bioagent release in domestic water supplies. An optimized eluent solution was determined experimentally by quantifying recoveries of microorganisms from point-of-use (POU) drinking water filters. The optimized extraction protocol was then used in mock bioagent release experiments to determine the feasibility of POU filters as bioforensic sampling devices. Bacillus atrophaeus spores, Escherichia coli and PP7 virus were exposed to filters and the number of attached organisms was determined by enumerating the unattached organisms on selective agar media. Subsequently, the filters were eluted and the percent of extracted organisms was determined based on the number of attached organisms. Two popular brands of carbon block filters retained 92%-99% of representative virus, spore and vegetative bacteria. In back-flush elutions of single filters, the most efficient eluent was identified as a combination of 1% peptone and 1% Tween-80, and extraction recovered 25.4% (+/-17.5%) of attached E. coli, 20.4% (+/-3.6%) of B. atrophaeus spores, and 9.4% (+/-5.2%) of PP7 virions (+/- standard deviations). In bioagent release studies in which filters were challenged with 100 agents mL(-1), greater than 99% of the spores were retained by the filters, and the percent of attached spores that were recovered ranged from 10.4% at day 0 to 4.3% five days after the release event (averaged from five separate experiments). In contrast, E. coli, Salmonella typhimurium and PP7 virus were rapidly inactivated in the chlorinated tap water, indicating their improbable survival in chlorinated water supplies. It is therefore concluded that household water filters can be used as microbial sampling devices for bioforensic applications in the event of a bioagent release in domestic drinking water supplies. PMID:18528538

  10. Assessment of the elution of charcoal, cellulose acetate, and other particles from cigarettes with charcoal and activated charcoal/resin filters.

    PubMed

    Agyei-Aye, K; Appleton, S; Rogers, R A; Taylor, C R

    2004-08-01

    This experiment was designed to study the release of cellulose acetate fibers, charcoal, and other particles from cigarettes with charcoal and activated charcoal/resin filters. For the first time in such studies, efforts were made to identify the particles that were eluted using other analytical techniques in addition to light microscopy. Other corrective measures were also implemented. During the studies it was found that trimming of larger filters to fit smaller filter housings introduced cellulose acetate-like particles from the fibers of the filter material. Special, custom made-to-fit filters were used instead. Tools such as forceps that were used to retrieve filters from their housings were also found to introduce fragments onto the filters. It is believed that introduction of such debris may have accounted for the very large number of cellulose acetate and charcoal particles that had been reported in the literature. Use of computerized particle-counting microscopes appeared to result in excessive number of particles. This could be because the filter or smoke pads used for such work do not have the flat and level surfaces ideal for computerized particle-counting microscopes. At the high magnifications that the pads were viewed for particles, constant focusing of the microscope would be essential. It was also found that determination of total particles by using extrapolation of particle count by grid population usually gave extremely high particle counts compared to the actual number of particles present. This could be because particle distributions during smoking are not uniform. Lastly, a less complex estimation of the thickness of the particles was adopted. This and the use of a simple mathematical conversion coupled with the Cox equation were utilized to assess the aerodynamic diameters of the particles. Our findings showed that compared to numbers quoted in the literature, only a small amount of charcoal, cellulose acetate shards, and other particles are

  11. Treatment of a high-strength sulphate-rich alkaline leachate using an anaerobic filter

    SciTech Connect

    Wang, Z.; Banks, C.J.

    2007-07-01

    The research looks at the feasibility of treating an alkaline sulphate-rich leachate arising from the co-disposal of municipal solid waste with cement kiln dust by means of an anaerobic filter (AF). This type of leachate with a high sulphate concentration is commonly prohibited for discharge to sewer and requires an on-site treatment solution. The AF used had a working volume of 4 l and contained reticulated polyurethane foam as the biomass support material. The filters were operated over a 152 day experimental period during which the COD loading onto the filter was increased from 0.76 to 7.63 kg COD m{sup -3} d{sup -1}. In the early stages of operation at low loading, soluble sulphides accumulated that inhibited methanogenic activity. This was restored by dosing FeCl{sub 3} to the reactor. The continued dosing allowed efficient COD removal of between 75% and 90% until the nominal retention time in the reactor was 3 days, at which point reactor performance declined significantly. The main mechanism for COD removal was by sulphate-reducing bacteria, which also resulted in up to 88% sulphate removal from the leachate. The average methane generation rate was 0.10 l g{sup -1} COD removed. The results indicate the potential for using this approach as a pre-treatment that could significantly reduce the COD load to a second stage treatment process, but problems associated with the implementation of the technology at a larger scale have been identified.

  12. Model for trace metal exposure in filter-feeding flamingos at alkaline Rift Valley Lake, Kenya

    SciTech Connect

    Nelson, Y.M.; DiSante, C.J.; Lion, L.W.; Thampy, R.J.; Raini, J.A.; Motelin, G.K.

    1998-11-01

    Toxic trace metals have been implicated as a potential cause of recent flamingo kills at Lake Nakuru, Kenya. Chromium (Cr), copper (Cu), lead (Pb), and zinc (Zn) have accumulated in the lake sediments as a result of unregulated discharges and because this alkaline lake has no natural outlet. Lesser flamingos (Phoeniconaias minor) at Lake Nakuru feed predominantly on the cyanobacterium Spirulina platensis, and because of their filter-feeding mechanism, they are susceptible to exposure to particle-bound metals. Trace metal adsorption isotherms to lake sediments and S. platensis were obtained under simulated lake conditions, and a mathematical model was developed to predict metal exposure via filter feeding based on predicted trace metal phase distribution. Metal adsorption to suspended solids followed the trend Pb {much_gt} Zn > Cr > Cu, and isotherms were linear up to 60 {micro}g/L. Adsorption to S. platensis cells followed the trend Pb {much_gt} Zn > Cu > Cr and fit Langmuir isotherms for Cr, Cu and Zn and a linear isotherm for Pb. Predicted phase distributions indicated that Cr and Pb in Lake Nakuru are predominantly associated with suspended solids, whereas Cu and Zn are distributed more evenly between the dissolved phase and particulate phases of both S. platensis and suspended solids. Based on established flamingo feeding rates and particle size selection, predicted Cr and Pb exposure occurs predominantly through ingestion of suspended solids, whereas Cu and Zn exposure occurs through ingestion of both suspended solids and S. platensis. For the lake conditions at the time of sampling, predicted ingestion rates based on measured metal concentrations in lake suspended solids were 0.71, 6.2, 0.81, and 13 mg/kg-d for Cr, Cu, Pb, and Zn, respectively.

  13. Evaluation of electrochemical ion exchange for cesium elution

    SciTech Connect

    Bontha, J.D.; Kurath, D.E.; Surma, J.E.; Buehler, M.F.

    1996-04-01

    Electrochemical elution was investigated as an alternative method to acid elution for the desorption of cesium from loaded ion exchange resins. The approach was found to have several potential advantages over existing technologies, in particular, electrochemical elution eliminates the need for addition of chemicals to elute cesium from the ion exchange resin. Also, since, in the electrochemical elution process the eluting solution is not in direct contact with the ion exchange material, very small volumes of the eluting solution can be used in a complete recycle mode in order to minimize the total volume of the cesium elute. In addition, the cesium is eluted as an alkaline solution that does not require neutralization with caustic to meet the tank farm specifications. Other advantages include easy incorporation of the electrochemical elution process into the present cesium recovery schemes.

  14. Facile and Sensitive Fluorescence Sensing of Alkaline Phosphatase Activity with Photoluminescent Carbon Dots Based on Inner Filter Effect.

    PubMed

    Li, Guoliang; Fu, Huili; Chen, Xuejie; Gong, Peiwei; Chen, Guang; Xia, Lian; Wang, Hua; You, Jinmao; Wu, Yongning

    2016-03-01

    A simple and sensitive fluorescent assay for detecting alkaline phosphatase (ALP) based on the inner filter effect (IFE) has been proven, which is conceptually different from the previously reported ALP fluorescent assays. In this sensing platform, N-doped carbon dots (CDs) with a high quantum yield of 49% were prepared by one-pot synthesis and were directly used as a fluorophore in IFE. p-Nitrophenylphosphate (PNPP) was employed to act as an ALP substrate, and its enzyme catalytic product (p-nitrophenol (PNP)) was capable of functioning as a powerful absorber in IFE to influence the excitation of fluorophore (CDs). When in the presence of ALP, PNPP was transformed into PNP and induced the absorption band transition from 310 to 405 nm, which resulted in the complementary overlap between the absorption of PNP and the excitation of CDs. Because of the competitive absorption, the excitation of CDs was significantly weakened, resulting in the quenching of CDs. The present IFE-based sensing strategy showed a good linear relationship from 0.01 to 25 U/L (R(2) = 0.996) and provided an exciting detection limit of 0.001 U/L (signal-to-noise ratio of 3). The proposed sensing approach was successfully applied to ALP sensing in serum samples, ALP inhibitor investigation and phosphatase cell imaging. The presented IFE-based CDs fluorescence sensing strategy gives new insight on the development of the facile and sensitive optical probe for enzyme activity assay because the surface modification or the linking between the receptor and the fluorophore is no longer required. PMID:26820049

  15. Determination of nicotine, tar, volatile organic compounds and carbonyls in mainstream cigarette smoke using a glass filter and a sorbent cartridge followed by the two-phase/one-pot elution method with carbon disulfide and methanol.

    PubMed

    Uchiyama, Shigehisa; Hayashida, Hideki; Izu, Rina; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2015-12-24

    We have developed a new analytical method for the determination of nicotine, tar, volatile organic compounds and carbonyls in main-stream cigarette smoke using a sorbent cartridge packed with Carboxen 572 (CX-572) and a Cambridge filter pad (CFP) followed by the two-phase/one-pot elution method. A CX-572 cartridge is installed between the intake of the CFP and the pump of the smoking machine. Gaseous compounds collected with the CX-572 cartridge and total particulate matter (TPM) collected with the CFP are coeluted simultaneously in the same vial and then analyzed by high-performance liquid chromatography (HPLC), gas chromatography-mass spectrometry (GC/MS) and gas chromatograph-thermal conductivity detector (GC/TCD). Carbonyl compounds are determined by adding derivatizing reagent (2,4-dinitrophenylhydrazine, DNPH) to the eluate followed by HPLC analysis. VOCs and nicotine are determined by GC/MS, and water is determined by GC/TCD. The same sample eluate solution is used for HPLC, GC/MS and GC/TCD analyses. As a result of measuring main-stream cigarette smoke generated from reference cigarettes, almost all carbonyl compounds and VOCs except formaldehyde were passed through a CFP and trapped in a CX-572 cartridge. 100% of nicotine, tar and TPM were trapped in a CFP. 50% of water and 53% of formaldehyde were trapped in a CFP. The one-pot data is almost equal to the sums of CFP (particulate matter) and CX-572 (gaseous compounds) data. The two-phase/one-pot elution method can simultaneously measure nicotine, tar, volatile organic compounds and carbonyl compounds in cigarette smoke with simple operation and small amounts of reagents. PMID:26653840

  16. ELUTION OF URANIUM FROM RESIN

    DOEpatents

    McLEan, D.C.

    1959-03-10

    A method is described for eluting uranium from anion exchange resins so as to decrease vanadium and iron contamination and permit recycle of the major portion of the eluats after recovery of the uranium. Diminution of vanadium and iron contamination of the major portion of the uranium is accomplished by treating the anion exchange resin, which is saturated with uranium complex by adsorption from a sulfuric acid leach liquor from an ore bearing uranium, vanadium and iron, with one column volume of eluant prepared by passing chlorine into ammonium hydroxide until the chloride content is about 1 N and the pH is about 1. The resin is then eluted with 8 to 9 column volumes of 0.9 N ammonium chloride--0.1 N hydrochloric acid solution. The eluants are collected separately and treated with ammonia to precipitate ammonium diuranate which is filtered therefrom. The uranium salt from the first eluant is contaminated with the major portion of ths vanadium and iron and is reworked, while the uranium recovered from the second eluant is relatively free of the undesirable vanadium and irons. The filtrate from the first eluant portion is discarded. The filtrate from the second eluant portion may be recycled after adding hydrochloric acid to increase the chloride ion concentration and adjust the pH to about 1.

  17. Sequential elution process

    DOEpatents

    Kingsley, Ilse S.

    1987-01-01

    A process and apparatus for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials.

  18. Sequential elution process

    DOEpatents

    Kingsley, I.S.

    1987-01-06

    A process and apparatus are disclosed for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials. 1 fig.

  19. Drug-eluting medical implants.

    PubMed

    Zilberman, Meital; Kraitzer, Amir; Grinberg, Orly; Elsner, Jonathan J

    2010-01-01

    Drug-eluting medical implants are actually active implants that induce healing effects, in addition to their regular task of support. This effect is achieved by controlled release of active pharmaceutical ingredients (API) into the surrounding tissue. In this chapter we focus on three types of drug-eluting devices: drug-eluting vascular stents, drug-eluting wound dressings and protein-eluting scaffolds for tissue regeneration, thus describing both internal and external implants. Each of these drug-eluting devices also presents an approach for solving the drug release issue. Most drug-eluting vascular stents are loaded with water-insoluble antiproliferative agents, and their diffusion from the device to the surrounding tissue is relatively slow. In contrast, most drug-eluting wound dressings are loaded with highly water-soluble antibacterial agents and the issue of fast release must therefore be addressed. Growth factor release from scaffolds for tissue regeneration offers a new approach of incorporating high-molecular-weight bioactive agents which are very sensitive to process conditions and preserve their activity during the preparation stage. The drug-eluting medical implants are described here in terms of matrix formats and polymers, incorporated drugs and their release profiles from the implants, and implant functioning. Basic elements, such as new composite core/shell fibers and structured films, can be used to build new antibiotic-eluting devices. As presented in this chapter, the effect of the processing parameters on the microstructure and the resulting drug release profiles, mechanical and physical properties, and other relevant properties, must be elucidated in order to achieve the desired properties. Newly developed implants and novel modifications of previously developed approaches have enhanced the tools available for creating clinically important biomedical applications. PMID:20217535

  20. Potential for use of industrial waste materials as filter media for removal of Al, Mo, As, V and Ga from alkaline drainage in constructed wetlands--adsorption studies.

    PubMed

    Hua, T; Haynes, R J; Zhou, Y-F; Boullemant, A; Chandrawana, I

    2015-03-15

    The potential to remove Al, Mo, V, As and Ga from alkaline (pH 8.0-8.6) drainage originating from seawater neutralized bauxite processing residue storage areas using constructed wetland technology was studied in a laboratory study. Bauxite processing residue sand, bauxite, alum water treatment sludge and blast furnace slag were investigated as potential active filter materials. Al was shown to precipitate as Al(OH)3 in the pH range 7.0-8.0 in aqueous solution and 6.0-8.5 in the presence of silica sand particles that provided a surface for nucleation. For V As Mo and Ga, adsorption to the surfaces of the adsorbents decreased greatly at elevated pH values (>pH 6-9). Water treatment sludge and bauxite had a greater ability to adsorb V, As and Mo at high pH (As and V at pH 7-9 and Mo at pH 5-7) than processing sand and slag. Adsorption isotherm data for As and V onto all four adsorbent than processing sand and slag. Adsorption isotherm data for As and V onto all four adsorbent materials fitted equally well to the Langmuir and Freundlich equations but for Ga, and to a lesser extent Mo, the Freundlich equation gave higher R(2) values. For all four ions, the maximum adsorption capacity (Langmuir value qmax) was greatest for water treatment sludge. Bauxite adsorbed more Mo, Ga and V than residue sand or slag. The pseudo-second order equation gave a better fit to the experimental kinetic data than the pseudo-first order model suggesting that chemisorption rather than diffusion/exchange was the rate limiting step to adsorption. It was concluded that water treatment sludge and bauxite were the most effective adsorbents and that for effective removal of the target ions the pH of the drainage water needs to be decreased to 6.0-7.0. PMID:25589434

  1. Simultaneous speciation analysis of chromate, molybdate, tungstate and vanadate in welding fume alkaline extracts by HPLC-ICP-MS.

    PubMed

    Ščančar, Janez; Berlinger, Balázs; Thomassen, Yngvar; Milačič, Radmila

    2015-09-01

    A novel analytical procedure was developed for the simultaneous speciation analysis of chromate, molybdate, tungstate and vanadate by anion-exchange high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC-ICP-MS). Linear gradient elution from 100% water to 100% 0.7 M NaCl was applied for chromatographic separation of metal species. In standard aqueous solution at neutral pH molybdate, tungstate and vanadate exist in several aqueous species, while chromate is present as a single CrO4(2-) species. Consequently, only chromate can be separated from this solution in a sharp chromatographic peak. For obtaining sharp chromatographic peaks for molybdate, tungstate and vanadate, the pH of aqueous standard solutions was raised to 12. At highly alkaline conditions single CrO4(2-), MoO4(2-) and WO4(2-) are present and were eluted in sharp chromatographic peaks, while VO4(3-) species, which predominates at pH 12 was eluted in slightly broaden peak. In a mixture of aqueous standard solutions (pH 12) chromate, molybdate, tungstate and vanadate were eluted at retention times from 380 to 420 s, 320 to 370 s, 300 to 350 s and 240 to 360 s, respectively. Eluted species were simultaneously detected on-line by ICP-MS recording m/z 52, 95, 182 and 51. The developed procedure was successfully applied to the analysis of leachable concentrations of chromate, molybdate, tungstate and vanadate in alkaline extracts (2% NaOH+3% Na2CO3) of manual metal arc (MMA) welding fumes loaded on filters. Good repeatability and reproducibility of measurement (RSD±3.0%) for the investigated species were obtained in both aqueous standard solutions (pH 12) and in alkaline extracts of welding fumes. Low limits of detection (LODs) were found for chromate (0.02 ng Cr mL(-1)), molybdate (0.1 ng Mo mL(-1)), tungstate (0.1 ng W mL(-1)) and vanadate (0.2 ng V mL(-1)). The accuracy of analytical procedure for the determination of chromate was checked by analysis of

  2. Normalized Elution Time Prediction Utility

    2011-02-17

    This program is used to compute the predicted normalized elution time (NET) for a list of peptide sequences. It includes the Kangas/Petritis neural network trained model, the Krokhin hydrophobicity model, and the Mant hydrophobicity model. In addition, it can compute the predicted strong cation exchange (SCX) fraction (on a 0 to 1 scale) in which a given peptide will appear.

  3. Elution of Ti during solvent extraction of coal and the transformation of eluted Ti upon combustion

    SciTech Connect

    Zhang, L.A.; Takanohashi, T.; Saito, I.; Wang, Q.Y.; Ninomiya, Y.

    2008-06-15

    Solvent extraction of coal is an effective method for removing coal ash, thereby generating the ultraclean fuel that can be directly combusted in gas turbine. Due to their organic affinity, a few inorganic elements can be extracted as well. Ti in coal extract, its elution from raw coal as well as the transformation of eluted Ti during coal extract combustion, have been investigated. Two coals of the U.S. and their acid-washed samples were extracted under 1 MPa N{sub 2} (cold) at 360{sup o}C. The solvents used include nonpolar 1-methylnaphthalene and its mixtures with polar indole. The results indicate that, Ti in coal extracts is mainly composed of nanoparticles including TiO{sub 2} (anatase) and Ti associated with quartz. These particles are insoluble in any acids, having a fine dispersion into coal matrix. Upon coal fragmentation at 360{sup o}C, they could be liberated, and, hence, traversed the filter for isolating coal extracts. The organo-Ti was preferentially extracted as well, which is most likely in a form of Ti porphyrin or Ti chelated with phenol-oxygen. These findings also have implications for revealing the modes of occurrence of Ti in the raw coals. Combustion of coal extract at 1,000{sup o}C resulted in the formation of nanometric TiO{sub 2} polymorphs and complex compounds like FeZnTiO{sub 4}. The former species could be mainly formed by the phase change of TiO{sub 2} (anatase) at high-temperatures, while formation of the latter one could involve the capture of metallic vapors like Zn on TiO{sub 2} polymorphs.

  4. EVALUATION OF POTENTIAL ELUANTS FOR NON-ACID ELUTION OF CESIUM FROM RESORCINOL-FORMALDEHYDE RESIN

    SciTech Connect

    Adu-Wusu, K.; Pennebaker, F.

    2010-12-22

    Small-column ion exchange (SCIX) units installed in high-level waste tanks to remove Cs-137 from highly alkaline salt solutions are among the waste treatment plans in the DOE-complex. Spherical Resorcinol-Formaldehyde (sRF) is the ion exchange resin selected for use in the Hanford Waste Treatment and Immobilization Plant (WTP). It is also the primary ion exchange material under consideration for SCIX at the Hanford site. The elution step of the multi-step ion exchange process is typically done with 0.5 M nitric acid. An acid eluant is a potential hazard in the event of a spill, leak, etc. because the high-level waste tanks are made of carbon steel. Corrosion and associated structural damage may ensue. A study has been conducted to explore non-acid elution as an alternative. Batch contact sorption equilibrium screening tests have been conducted with 36 potential non-acid eluants. The sorption tests involve equilibrating each cesium-containing eluant solution with the sRF resin for 48 hours at 25 C in a shaker oven. In the sorption tests, an eluant is deemed to have a high cesium elution potential if it minimizes cesium sorption onto the sRF resin. The top candidates (based on lowest cesium sorption distribution coefficients) include ammonium carbonate, ammonium carbonate/ammonium hydroxide, ammonium bicarbonate, rubidium carbonate, ammonium acetate, ammonium acetate/ammonium hydroxide, ammonium bicarbonate/ammonium hydroxide, calcium chloride, and magnesium chloride. A select few of the top candidate eluants from the screening tests were subjected to actual sorption (loading) and elution tests to confirm their elution ability. The actual sorption (loading) and elution tests mimicked the typical sRF-cesium ion exchange process (i.e., sorption or loading, caustic wash, water rinse, and elution) via batch contact sorption and quasi column caustic wash/water rinse/elution. The eluants tested included ammonium carbonate, ammonium acetate, calcium acetate, magnesium

  5. Gradient elution in capillary electrochromatography

    SciTech Connect

    Anex, D.; Rakestraw, D.J.; Yan, Chao; Dadoo, R.; Zare, R.N.

    1997-08-01

    In analogy to pressure-driven gradient techniques in high-performance liquid chromatography, a system has been developed for delivering electroosmotically-driven solvent gradients for capillary electrochromatography (CEC). Dynamic gradients with sub-mL/min flow rates are generated by merging two electroosmotic flows that are regulated by computer-controlled voltages. These flows are delivered by two fused-silica capillary arms attached to a T-connector, where they mix and then flow into a capillary column that has been electrokinetically packed with 3-mm reversed-phase particles. The inlet of one capillary arm is placed in a solution reservoir containing one mobile phase and the inlet of the other is placed in a second reservoir containing a second mobile phase. Two independent computer-controlled programmable high-voltage power supplies (0-50 kV)--one providing an increasing ramp and the other providing a decreasing ramp--are used to apply variable high-voltage potentials to the mobile phase reservoirs to regulate the electroosmotic flow in each arm. The ratio of the electroosmotic flow rates between the two arms is changed with time according to the computer-controlled voltages to deliver the required gradient profile to the separation column. Experiments were performed to confirm the composition of the mobile phase during a gradient run and to determine the change of the composition in response to the programmed voltage profile. To demonstrate the performance of electroosmotically-driven gradient elution in CEC, a mixture of 16 polycyclic aromatic hydrocarbons (PAHs) was separated in less than 90 minutes. This gradient technique is expected to be well-suited for generating not only solvent gradients in CEC, but also other types of gradients such as pH- and ionic-strength gradients in capillary electrokinetic separations and analyses.

  6. Evaluation of the celite secondary concentration procedure and an alternate elution buffer for the recovery of enteric adenoviruses 40 and 41

    EPA Science Inventory

    The effective recovery of adenovirus from water is a critical first step in developing a virus occurrence method able to provide accurate data for risk assessments and other applications. During virus concentration, electropositive filters are typically eluted with beef extract,...

  7. Alkaline sorbent injection for mercury control

    DOEpatents

    Madden, Deborah A.; Holmes, Michael J.

    2002-01-01

    A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

  8. Alkaline sorbent injection for mercury control

    DOEpatents

    Madden, Deborah A.; Holmes, Michael J.

    2003-01-01

    A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

  9. Paclitaxel-Eluting versus Everolimus-Eluting Coronary Stents in Diabetes.

    PubMed

    2016-07-28

    Paclitaxel-Eluting versus Everolimus-Eluting Coronary Stents in Diabetes Original Article, N Engl J Med 2015;373:1709-1719. In the list of authors (page 1709), the surname Abhaychand should have been Abhaichand. The article is correct at NEJM.org. PMID:27464221

  10. Fractionated elution using the TEKCIS technetium-99m generator.

    PubMed

    Vigne, Jonathan; De Mil, Rémy; Peyronnet, Damien; Hecquard, Claudine; Agostini, Denis; Lemonnier, Françoise

    2016-06-01

    The TEKCIS technetium-99m (Tc) generator was designed to allow dry column shipment and automatized conception. A high Tc radioactive concentration is required in a subset of radiopharmacy procedures. Fractionated elution can be a useful tool to meet this requirement, especially when current elution is close to the generator expiration date. The aim of our study was to assess TEKCIS generator elution kinetics and to determine the optimal fractionated elution time to fit with procedures requiring the highest Tc radioactive concentration in clinical use. After duplicate elution at several predetermined elution times, the volume and activity of each eluate were measured. Two optimal time points were selected to perform fractionated elution and repeatability (n=34 and 33) assessed on TEKCIS generators calibrated at 6 or 8 GBq. The complete eluate volume (5 ml) was collected after 60 s of elution. A logarithmic equation was established between eluate volume (v, ml) from elapsed elution time (t, s): v=1.8335ln(t)-2.5965. Using the reciprocal equation, elution times required to obtain some commonly eluted volumes were calculated. Fractionated elutions during 15 and 20 s were selected and an average elution volume from 2.74 to 3.27 ml was collected, with an average elution yield of approximately 90 and 100%, respectively. Our work provides a simple and reliable methodology for the use of fractionated elution with the new TEKCIS generator. PMID:26945284

  11. Establishing conditions for the storage and elution of rabies virus RNA using FTA® cards

    PubMed Central

    SAKAI, Takeo; ISHII, Ayako; SEGAWA, Takao; TAKAGI, Yukihiko; KOBAYASHI, Yuki; ITOU, Takuya

    2014-01-01

    The Flinders Technology Associates filter paper cards (FTA® cards) can be used to store nucleic acid from various samples and are easily portable. However, RNA is physicochemically unstable compared with DNA, and appropriate methods have not been established for storage and extraction of RNA from FTA® cards. The present study investigated the optimum conditions for storage and elution of viral RNA (vRNA) using rabies virus (RABV) applied to FTA® cards. When TE buffer was used, the elution rates of vRNA increased with the length of the elution time. When the cards were stored at −80°C or −20°C, vRNA was stable over 3 months. Degradation of vRNAs occurred following storage at 4°C and room temperature, suggesting that RNA should be extracted from cards as soon as possible if no freezer is available. When we tried to amplify vRNA from RABV-infected animal brains applied to FTA® cards and stored at −80°C for 6 months, we did not detect any amplified products with the primer set for 964 bp of RABV N gene. However, we were able to detect amplified products by increasing the elution time of vRNA from FTA® cards from 30 min to 24 hr or by changing the primer sets to amplify 290 bp of N gene. Thus, we recommend extending the elution time for damaged or low concentration samples in FTA® cards. PMID:25648208

  12. Highly porous drug-eluting structures

    PubMed Central

    Elsner, Jonathan J.; Kraitzer, Amir; Grinberg, Orly; Zilberman, Meital

    2012-01-01

    For many biomedical applications, there is need for porous implant materials. The current article focuses on a method for preparation of drug-eluting porous structures for various biomedical applications, based on freeze drying of inverted emulsions. This fabrication process enables the incorporation of any drug, to obtain an “active implant” that releases drugs to the surrounding tissue in a controlled desired manner. Examples for porous implants based on this technique are antibiotic-eluting mesh/matrix structures used for wound healing applications, antiproliferative drug-eluting composite fibers for stent applications and local cancer treatment, and protein-eluting films for tissue regeneration applications. In the current review we focus on these systems. We show that the release profiles of both types of drugs, water-soluble and water-insoluble, are affected by the emulsion's formulation parameters. The former's release profile is affected mainly through the emulsion stability and the resulting porous microstructure, whereas the latter's release mechanism occurs via water uptake and degradation of the host polymer. Hence, appropriate selection of the formulation parameters enables to obtain desired controllable release profile of any bioactive agent, water-soluble or water-insoluble, and also fit its physical properties to the application. PMID:23507890

  13. ALP (Alkaline Phosphatase) Test

    MedlinePlus

    ... known as: ALK PHOS; Alkp Formal name: Alkaline Phosphatase Related tests: AST ; ALT ; GGT ; Bilirubin ; Liver Panel ; Bone Markers ; Alkaline Phosphatase Isoenzymes; Bone Specific ALP All content on Lab ...

  14. ELUTION OF URANIUM VALUES FROM ION EXCHANGE RESINS

    DOEpatents

    Kennedy, R.H.

    1959-11-24

    A process is described for eluting complex uranium ions absorbed on ion exchange resins. The resin is subjected to the action of an aqueous eluting solution contuining sulfuric acid and an alkali metal, ammonium, or magnesium chloride or nitrate, the elution being carried out until the desired amount of the uranium is removed from the resin.

  15. Coronary vasomotion dysfunction after everolimus-eluting stent implantation.

    PubMed

    Giudice, Pietro; Attisano, Tiziana; Di Maio, Marco; Bellino, Elisabetta M; Polito, Maria V; Baldi, Cesare; Vigorito, Francesco; Di Muro, Michele R; Tomasello, Salvatore D; Galassi, Alfredo R; Piscione, Federico

    2014-12-01

    First generation drug-eluting stent can cause a paradoxical "in-segment" coronary vasoconstriction. This phenomenon was seen with sirolimus, paclitaxel, and, more recently, also with zotarolimus-eluting stent. For the first time, we describe a case of coronary-induced vasoconstriction by everolimus-eluting stents (EES). PMID:25598992

  16. Recent Advances in Drug Eluting Stents

    PubMed Central

    Puranik, Amey S.; Dawson, Eileen R.; Peppas, Nicholas A.

    2013-01-01

    One of the most common medical interventions to reopen an occluded vessel is the implantation of a coronary stent. While this method of treatment is effective initially, restenosis, or the re-narrowing of the artery frequently occurs largely due to neointimal hyperplasia of smooth muscle cells. Drug eluting stents were developed in order to provide local, site-specific, controlled release of drugs that can inhibit neointima formation. By implementing a controlled release delivery system it may be possible to control the time release of the pharmacological factors and thus be able to bypass some of the critical events associated with stent hyperplasia and prevent the need for subsequent intervention. However, since the advent of first-generation drug eluting stents, long-term adverse effects have raised concerns regarding their safety. These limitations in safety and efficacy have triggered considerable research in developing biodegradable stents and more potent drug delivery systems. In this review, we shed light on the current state-of-the-art in drug eluting stents, problems related to them and highlight some of the ongoing research in this area. PMID:23117022

  17. The Supralimus sirolimus-eluting stent.

    PubMed

    Lemos, Pedro A; Bienert, Igor

    2013-05-01

    The use of biodegradable polymeric coatings has emerged as a potential bioengineering target to improve the vascular compatibility of coronary drug-eluting stents (DESs). This review summarizes the main features and scientific facts about the Supralimus sirolimus-eluting stent (Sahajanand Medical Technologies Ltd, Surat, India), which is a biodegradable polymer-based, sirolimus-eluting metallic stent that was recently introduced for routine use in Europe. The novel stent is built on a stainless steel platform, coated with a blend of biodegradable polymers (poly-l-lactide, poly-dl-lactide-co-glycolide and polyvinyl pyrrolidone; coating thickness is 4-5 µm). The active agent is the antiproliferative sirolimus in a dose load of 1.4 µg/mm(2), which is released within 48 days. The Supralimus stent was initially evaluated in the single-arm SERIES-I study, which showed binary angiographic restenosis rates of 0% (in-stent) and 1.7% (in-segment) and an in-stent late lumen loss of 0.09 ± 0.28 mm. The multicenter randomized PAINT trial compared two DESs with identical metallic platforms and biodegradable polymer carriers, but different agents (Infinnium [Sahajanand Medical Technologies Pvt Ltd] paclitaxel-eluting stent or Supralimus sirolimus-eluting stent) against bare stents. After 3 years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9 vs 7.1%; p = 0.6), but a lower risk of repeat interventions (10 vs 29.9%; p < 0.01) than controls with bare stents. The incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (1st year: 1.8%; 2nd year: 0.4% and 3rd year: 0%). These results demonstrate that the novel Supralimus stents are effective in reducing reintervention, while potentially improving the safety profile by decreasing the risk of late-term thrombosis, even though further studies would be necessary to confirm these findings. PMID:23597097

  18. [Drug-eluting stents: long-term safety].

    PubMed

    Karpov, Iu A; Samko, A N; Buza, V V

    2009-01-01

    The review concerns the problem of late thromboses of drug-eluting stents and their influence on late prognosis of the patients; presents long-term results of the trial of sirolimus-eluting stents implanted to patients with coronary heart disease; analyses mechanisms of development of late stent thrombosis, data from different meta-analyses and registers comparing long-term outcomes in patients with implanted sirolimus-eluting stents and metallic stents; suggests risk factors of late thromboses of drug-eluting stents; presents original evidence on 3.5-year follow-up of patients with implanted sirolimus-eluting stents and metallic stents. PMID:19537584

  19. Quantifying phytate in dairy digesta and feces: alkaline extraction and high-performance ion chromatography.

    PubMed

    Ray, P P; Shang, C; Maguire, R O; Knowlton, K F

    2012-06-01

    Development of an analytical method with appropriate combination of extraction and quantification approaches for undigested phytate in ruminant feces and digesta will advance knowledge of phytate degradation in ruminants and help to reduce phosphorus excretion. Established quantification methods give satisfactory results for feedstuffs and nonruminant manure but recovery of phytate is incomplete for ruminant feces and digesta because of their complex sample matrix and low ratio of phytate to inorganic P. The objective was to develop a robust, accurate, sensitive, and inexpensive method to extract and quantify phytate in feeds, ruminant feces, and digesta. Diets varying in phytate content were fed to dairy heifers, dry cows, and lactating cows to generate digesta and fecal samples of varying composition to challenge extraction and quantification methods. Samples were extracted with 0.5 M HCl or 0.25 M NaOH + 0.05 M EDTA. Acid extracts were mixed with 20% NaCl, alkaline extracts were acidified to final pH < 2, and then both extracts were clarified with C₁₈ cartridges and 0.2-μm filters. High-performance ion chromatography (HPIC) was used to quantify phytate. In feed samples, the measured phytate was comparable in alkaline and acid extracts (2,965 vs. 3,085 μg/g of DM). In digesta and fecal samples, alkaline extraction yielded greater estimates of phytate content than did acid extraction (40.7 vs. 33.6 and 202.9 vs. 144.4 μg/g of DM for digesta and fecal samples, respectively). Analysis of alkaline extracts by HPIC is usually not possible because of sample matrix interferences; acidification and C(18)-cartridge elution of alkaline extracts prevented this interference. Pure phytate added to dry samples before extraction was almost completely recovered (88 to 105%), indicating high extraction efficiency, no adverse effect of extract clean-up procedures, and accurate quantification of phytate. The proposed method is rapid, inexpensive, robust, and combines the

  20. Alkaline detergent recycling via ultrafiltration

    SciTech Connect

    Steffani, C.; Meltzer, M.

    1995-06-01

    The metal finishing industry uses alkaline cleaners and detergents to remove oils and dirt from manufactured parts, often before they are painted or plated. The use of these cleaners has grown because environmental regulations are phasing out ozone depleting substances and placing restrictions on the use and disposal of many hazardous solvents. Lawrence Livermore National Laboratory is examining ultrafiltration as a cleaning approach that reclaims the cleaning solutions and minimizes wastes. The ultrafiltration membrane is made from sheets of polymerized organic film. The sheets are rolled onto a supporting frame and installed in a tube. Spent cleaning solution is pumped into a filter chamber and filtered through the membrane that captures oils and dirt and allows water and detergent to pass. The membrane is monitored and when pressure builds from oil and dirt, an automatic system cleans the surface to maintain solution flow and filtration quality. The results show that the ultrafiltration does not disturb the detergent concentration or alkalinity but removed almost all the oils and dirt leaving the solution in condition to be reused.

  1. Prediction of Neutral Salt Elution Profiles for Affinity Chromatography

    NASA Astrophysics Data System (ADS)

    Robinson, Jack B.; Strottmann, James M.; Stellwagen, Earle

    1981-04-01

    Neutral salts exhibit very marked differences as eluants of proteins from affinity columns. We observe: (i) that the relative potencies of neutral salts as eluants are independent of the protein or the affinity ligand in the systems studied, (ii) that the absolute salt concentration necessary to elute any given protein bound to the affinity matrix is proportional to the algebraic sum of a set of elution coefficients defined herein for the separate ions present in the solution, and (iii) that the proportionality between elution potency and elution coefficient is a function of the affinity of the protein for the immobilized ligand. Given the concentration of one neutral salt required for elution of a protein of interest from an affinity column, the elution capability of any neutral salt at any temperature can be quantitatively predicted for that protein. Accordingly, application and elution protocols for affinity chromatography can be designed to optimize the yield and fold purification of proteins.

  2. Second generation drug-eluting stents: a review of the everolimus-eluting platform.

    PubMed

    Whitbeck, Matthew G; Applegate, Robert J

    2013-01-01

    Everolimus-eluting stents (EES) represent the next generation of drug-eluting stents (DES). Important design modifications include thin strut stent backbones, less inflammatory and more biocompatible polymers, and lower drug dosing. The cobalt chromium EES fluoropolymer XIENCE V stent has been the most extensively studied of such stents. In animal models, this stent demonstrated minimal vessel inflammation, a biologically active endothelium with strut coverage similar to a bare metal stent, and inhibition of intimal hyperplasia comparable to that seen with sirolimus-eluting stents. The SPIRIT family of clinical trials demonstrated low rates of late loss, and clinical restenosis, as well as low rates of very late stent thrombosis. These excellent clinical outcomes addressed limitations of the 1st generation DES, and substantiated widespread clinical use of the EES platform. PMID:23926441

  3. Innovative Elution Processes for Recovering Uranium from Seawater

    SciTech Connect

    Wai, Chien; Tian, Guoxin; Janke, Christopher

    2014-05-29

    Utilizing amidoxime-based polymer sorbents for extraction of uranium from seawater has attracted considerable interest in recent years. Uranium collected in the sorbent is recovered typically by elution with an acid. One drawback of acid elution is deterioration of the sorbent which is a significant factor that limits the economic competitiveness of the amidoxime-based sorbent systems for sequestering uranium from seawater. Developing innovative elution processes to improve efficiency and to minimize loss of sorbent capacity become essential in order to make this technology economically feasible for large-scale industrial applications. This project has evaluated several elution processes including acid elution, carbonate elution, and supercritical fluid elution for recovering uranium from amidoxime-based polymer sorbents. The elution efficiency, durability and sorbent regeneration for repeated uranium adsorption- desorption cycles in simulated seawater have been studied. Spectroscopic techniques are used to evaluate chemical nature of the sorbent before and after elution. A sodium carbonate-hydrogen peroxide elution process for effective removal of uranium from amidoxime-based sorbent is developed. The cause of this sodium carbonate and hydrogen peroxide synergistic leaching of uranium from amidoxime-based sorbent is attributed to the formation of an extremely stable uranyl peroxo-carbonato complex. The efficiency of uranium elution by the carbonate-hydrogen peroxide method is comparable to that of the hydrochloric acid elution but damage to the sorbent material is much less for the former. The carbonate- hydrogen peroxide elution also does not need any elaborate step to regenerate the sorbent as those required for hydrochloric acid leaching. Several CO2-soluble ligands have been tested for extraction of uranium from the sorbent in supercritical fluid carbon dioxide. A mixture of hexafluoroacetylacetone and tri-n-butylphosphate shows the best result but uranium

  4. Modelling Simple Experimental Platform for In Vitro Study of Drug Elution from Drug Eluting Stents (DES)

    NASA Astrophysics Data System (ADS)

    Kalachev, L. V.

    2016-06-01

    We present a simple model of experimental setup for in vitro study of drug release from drug eluting stents and drug propagation in artificial tissue samples representing blood vessels. The model is further reduced using the assumption on vastly different characteristic diffusion times in the stent coating and in the artificial tissue. The model is used to derive a relationship between the times at which the measurements have to be taken for two experimental platforms, with corresponding artificial tissue samples made of different materials with different drug diffusion coefficients, to properly compare the drug release characteristics of drug eluting stents.

  5. CONCENTRATION OF POLIOVIRUS FROM TAP WATER USING POSITIVELY CHARGED MICROPOROUS FILTERS

    EPA Science Inventory

    Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentration from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cel...

  6. The future of drug eluting stents

    PubMed Central

    Anis, R R; Karsch, K R

    2006-01-01

    In‐stent restenosis (ISR) is the major drawback of percutaneous coronary interventions, occurring in 10–40% of patients. Drug eluting stents (DES) are successful in a large majority of patients in preventing restenosis for the first year after implantation. Recently, new stents have emerged that are loaded with anti‐inflammatory, antimigratory, antiproliferative, or pro‐healing drugs. These drugs are supposed to inhibit inflammation and neointimal growth and subsequently ISR. The future of DES lies in the development of better stents with new stent designs, better polymers including biological polymers and biological biodissolvable stent coatings, and new, better drugs. PMID:16216857

  7. Paclitaxel Drug-Eluting Stents in Peripheral Arterial Disease: A Health Technology Assessment

    PubMed Central

    2015-01-01

    Background Peripheral arterial disease is a condition in which atherosclerotic plaques partially or completely block blood flow to the legs. Although percutaneous transluminal angioplasty and metallic stenting have high immediate success rates in treating peripheral arterial disease, long-term patency and restenosis rates in long and complex lesions remain unsatisfactory. Objective The objective of this analysis was to evaluate the clinical effectiveness, safety, cost-effectiveness and budget impact of Zilver paclitaxel self-expanding drug-eluting stents for the treatment of de novo or restenotic lesions in above-the-knee peripheral arterial disease. Data Sources Literature searches were performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews. For the economic review, a search filter was applied to limit search results to economics-related literature. Data sources for the budget impact analysis included expert opinion, published literature, and Ontario administrative data. Review Methods Systematic reviews, meta-analyses, randomized controlled trials, and observational studies were included in the clinical effectiveness review, and full economic evaluations were included in the economic literature review. Studies were included if they examined the effect of Zilver paclitaxel drug-eluting stents in de novo or restenotic lesions in above-the-knee arteries. For the budget impact analysis, 3 scenarios were constructed based on different assumptions. Results One randomized controlled trial reported a significantly higher patency rate with Zilver paclitaxel drug-eluting stents for lesions ≤ 14 cm than with angioplasty or bare metal stents. One observational study showed no difference in patency rates between Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. Zilver paclitaxel drug-eluting stents were associated with

  8. Alkaline "Permanent" Paper.

    ERIC Educational Resources Information Center

    Pacey, Antony

    1991-01-01

    Discussion of paper manufacturing processes and their effects on library materials focuses on the promotion of alkaline "permanent" paper, with less acid, by Canadian library preservation specialists. Standards for paper acidity are explained; advantages of alkaline paper are described, including decreased manufacturing costs; and recyclability is…

  9. Anodes for alkaline electrolysis

    DOEpatents

    Soloveichik, Grigorii Lev

    2011-02-01

    A method of making an anode for alkaline electrolysis cells includes adsorption of precursor material on a carbonaceous material, conversion of the precursor material to hydroxide form and conversion of precursor material from hydroxide form to oxy-hydroxide form within the alkaline electrolysis cell.

  10. Alkaline igneous rocks

    SciTech Connect

    Fitton, J.G.; Upton, B.G.J.

    1987-01-01

    In this volume, an international team of scientists provides an up-to-date overview of the nature, origin, and evolution of alkaline magmas. Particular attention is paid to carbonatites, lamprophyres, and lamproites which are rock suites of current interest not recently reviewed elsewhere. Recent work on the classical alkaline provinces of East Africa, South Greenland, and the Kola Peninsula is included together with reviews of other areas of alkaline magmatism in North and South America, East Greenland, Europe, West Africa, and the ocean basins. Other papers discuss the impact of experimental isotopic and geochemical studies of the petrogenesis of alkaline rocks. This book will be of interest to petrologists and geochemists studying alkaline igneous rocks, and to other earth scientists as a reference on the rapidly expanding field of igneous petrology.

  11. Evaluation of Elution Parameters for Cesium Ion Exchange Resins

    SciTech Connect

    Burgeson, Ingrid E.; Deschane, Jaquetta R.; Cook, Bryan J.; Blanchard, David L.; Weier, Dennis R.

    2006-08-28

    Cesium ion exchange is one of the planned processes for treating and disposing of waste at the U.S. Department of Energy Hanford Site. Radioactive supernatant liquids from the waste tanks will undergo ultrafiltration, followed by cesium ion exchange using a regenerable organic ion exchange resin. Two resins, SuperLig?644 and a Resorcinol-formaldehyde resin are being evaluated for cesium removal and cesium elution characteristics. The main purpose of this study is to optimize the cesium elution to provide a resin which after undergoing elution would meet the U.S. Department of Energy/Office of River Protection Project-Waste Treatment Plant processing and resin disposal criteria. Columns of each resin type were loaded to greater or equal to 90% breakthrough with a Hanford waste stimulant and eluted with nitric acid. The temperature, flow rate and nitric acid concentration were varied to determine the optimal elution conditions. Temperature and eluant flow rate were the most important elution parameters. As would be predicted based upon kinetic consideration alone, decreasing the eluant flow rate and increasing the temperature provided the optimal elution conditions. Varying the nitric acid concentration did not have a significant effect on the elution; however, elutions performed using both high acid concentration (1M) and elevated temperature (45 C) resulted in resin degradation, causing gas generation and resin bed disruption.

  12. [Recent developments of drug eluting stent coatings].

    PubMed

    Chen, Wen-ping; Zhan, Hong-bing

    2011-11-01

    Drug eluting stents (DESs) have revolutionized the interventional cardiology over the past decade since the first DES became commercially available in Europe in 2002. Compared to bare metal stents that are deployed to keep the vessel open by mechanical force, DESs have an additional function of reducing restenosis by the action of the drug on the target site. Coatings on the stent surface which ensure the maximum delivery of therapeutic agents to the target site with minimal systematic toxicity, also play an important role in adjusting the drug release profile. Coating material and technology not only affect the surface biocompatibility and the integrity maintenance during the implanting process, but also decide the way of drug delivering and transmitting from the coating. This paper reviews the basic principles of DES coating design, the categories of DES coatings, the commonly used clinical DES coatings and their efficiency in reducing restenosis, and finally provides the future perspectives for DES coatings. PMID:22260019

  13. Alkaline battery operational methodology

    DOEpatents

    Sholklapper, Tal; Gallaway, Joshua; Steingart, Daniel; Ingale, Nilesh; Nyce, Michael

    2016-08-16

    Methods of using specific operational charge and discharge parameters to extend the life of alkaline batteries are disclosed. The methods can be used with any commercial primary or secondary alkaline battery, as well as with newer alkaline battery designs, including batteries with flowing electrolyte. The methods include cycling batteries within a narrow operating voltage window, with minimum and maximum cut-off voltages that are set based on battery characteristics and environmental conditions. The narrow voltage window decreases available capacity but allows the batteries to be cycled for hundreds or thousands of times.

  14. Native Elution of Yeast Protein Complexes Obtained by Affinity Capture.

    PubMed

    LaCava, John; Fernandez-Martinez, Javier; Rout, Michael P

    2016-01-01

    This protocol describes two options for the native (nondenaturing) elution of protein complexes obtained by affinity capture. The first approach involves the elution of complexes purified through a tag that includes a human rhinovirus 3C protease (PreScission protease) cleavage site sequence between the protein of interest and the tag. Incubation with the protease cleaves immobilized complexes from the affinity medium. The second approach involves the release of protein A-tagged protein complexes using a competitive elution reagent called PEGylOx. The degree of purity of the native assemblies eluted is sample dependent and strongly influenced by the affinity capture. It should be noted that the efficiency of native elution is commonly lower than that of elution by a denaturing agent (e.g., SDS) and the release of the complex will be limited by the activity of the protease or the inhibition constant (Ki) of the competitive release agent. However, an advantage of native release is that some nonspecifically bound materials tend to stay adsorbed to the affinity medium, providing an eluted fraction of higher purity. Finally, keep in mind that the presence of the protease or elution peptide could potentially affect downstream applications; thus, their removal should be considered. PMID:27371597

  15. Array tomography: immunostaining and antibody elution.

    PubMed

    Micheva, Kristina D; O'Rourke, Nancy; Busse, Brad; Smith, Stephen J

    2010-11-01

    Array tomography is a volumetric microscopy method based on physical serial sectioning. Ultrathin sections of a plastic-embedded tissue are cut using an ultramicrotome, bonded in an ordered array to a glass coverslip, stained as desired, and imaged. The resulting two-dimensional image tiles can then be reconstructed computationally into three-dimensional volume images for visualization and quantitative analysis. The minimal thickness of individual sections permits high-quality rapid staining and imaging, whereas the array format allows reliable and convenient section handling, staining, and automated imaging. Also, the physical stability of the arrays permits images to be acquired and registered from repeated cycles of staining, imaging, and stain elution, as well as from imaging using multiple modalities (e.g., fluorescence and electron microscopy). Array tomography makes it possible to visualize and quantify previously inaccessible features of tissue structure and molecular architecture. However, careful preparation of the tissue is essential for successful array tomography; these steps can be time-consuming and require some practice to perfect. In this protocol, tissue arrays are prepared for imaging by tagging with primary antibodies against specific cellular targets, followed by labeling with fluorescent secondary antibodies. Alternatively, fluorescent proteins that have been introduced into the tissue before dissection can be used. PMID:21041398

  16. Stack filters

    NASA Astrophysics Data System (ADS)

    Wendt, P. D.; Coyle, E. J.; Gallagher, N. C., Jr.

    1986-08-01

    A large class of easily implemented nonlinear filters called stack filters are discussed which includes the rank order operators in addition to the compositions of morphological operators. Techniques similar to those used to determine the root signal behavior of median filters are employed to study the convergence properties of the filters, and necessary conditions for a stack filter to preserve monotone regions or edges in signals, and the output distribution of the filters, are obtained. Among the stack filters of window width three are found asymmetric median filters in which one removes only positive going edges, the other removes only negative going edges, while the median filter removes impulses of both signs.

  17. [Elution of urinary proteins preserved on nitrocellulose membrane with heating].

    PubMed

    Qin, Weiwei; Gao, Youhe

    2015-09-01

    The preservation of urinary proteins on a membrane plays a vital role in biomarker research, and the efficient elution of proteins preserved on nitrocellulose membrane (NC membrane) determines the application of this method. During the heating elution procedure, we raised the temperature to reduce the intense vortexing time, and kept gentle rotating while precipitation to prevent nitrocellulose reformation. We also used SDS-PAGE and LC-MS/MS to analyze the urinary proteins prepared by heating elution procedure, intense vortexing elution procedure and acetone precipitation method. There was no degradation of proteins prepared by heating elution procedure. Compared with proteins prepared by heating elution method and acetone precipitation method, the overlapping rates of the proteins was almost the same (92.6% versus 96.8%) and the ratios of CV values (< 20%) of the proteins were both high (85.2% and 94.4%). The heating elution procedure achieved good technical reproducibility, and was much simpler and more efficient than the previous one. It can facilitate the application of the preservation of urinary proteins on membrane. PMID:26955716

  18. Comparisons of Aluminum and Silica Elution from Various Glass Vials.

    PubMed

    Ogawa, Toru; Miyajima, Makoto; Nishimoto, Norihiro; Minami, Hidemi; Terada, Katsuhide

    2016-01-01

    To understand the risk of particle formation in glass vials, we investigated the correlation between vial surface condition and alminum (Al) or silicon (Si) elution using various suppliers' vials with or without surface treatment. The elution of Si, which can also be an indicator of Al elution, consists of two phases; the first phase is influenced by roughness of the glass surface at the time of filling, and the second phase is dependent on the fundamental elution rate from the glass tube. When vials were filled with citrate buffer at pH 7, vials with varied surface conditions showed the most obvious differences in Al and Si elution. Sulfur-treated vials showed slightly lower Al and Si elution than the non-treated vials. It is considered that this effect of the sulfur treatment on elution is due to the surface being smoothed during heat treatment after the washing process. Different from the sulfur treatment, silicon dioxide (SiO2)-coated vials hardly showed any Al elution as long as the surface was fully coated with the SiO2 layer. It was found that the protective effect of the SiO2 layer against Al elution is more effective in a vial filled with a solution having a lower pH, due to the lower Si dissolving rate occurring at a lower pH. As shown above, pre-measuring the Si and Al present in a citrate buffer at pH 7 placed within a glass container can be a useful tool for selecting the appropriate container for liquid drugs. PMID:26656229

  19. Effect of pH on phosphorus, copper, and zinc elution from swine wastewater activated sludge.

    PubMed

    Waki, Miyoko; Yasuda, Tomoko; Fukumoto, Yasuyuki; Suzuki, Kazuyoshi

    2014-01-01

    With the goal of reducing the amounts of phosphorus (P), copper (Cu), and zinc (Zn) discharged from swine wastewater activated sludge treatment facilities, we studied the elution of these elements from activated sludge at various pH values. Sludge samples with neutral pH collected from three farms were incubated at pH values ranging from 3 to 10. The soluble concentrations of these elements changed dramatically with pH and were highest at pH 3. We assumed that P present in the sludge under neutral and alkaline conditions was in insoluble form bound up with magnesium (Mg) and calcium (Ca), because Ca and Mg also eluted from the sludge at low pH. To clarify forms of Zn and Cu in the sludge, we performed a sequential extraction analysis. Zinc in adsorbed, organically bound, and sulfide fractions made up a large proportion of the total Zn. Copper in organically bound, carbonate, and sulfide fractions made up a large proportion of the total Cu. The soluble P concentrations were lowest at pH 9 or 10 (11-36 mg/L), the soluble Zn concentrations were lowest at pH 8 or 9 (0.07-0.15 mg/L), and the soluble Cu concentrations were lowest at pH 6-9 (0.2 mg/L, the detection limit). PMID:25116486

  20. Alkaline flooding injection strategy

    SciTech Connect

    French, T.R.; Josephson, C.B.

    1992-03-01

    The objective of this project is to improved alkali-surfactant flooding methods, and this includes determining the proper design of injection strategy. Several different injection strategies have been used or suggested for recovering heavy oils with surfactant-enhanced alkaline flooding methods. Oil recovery was compared for four different injection strategies: (1) surfactant followed by polymer, (2) surfactant followed by alkaline polymer, (3) alkaline surfactant followed by polymer, and (4) alkali, surfactant, and polymer mixed in a single formulation. The effect of alkaline preflush was also studied under two different conditions. All of the oil recovery experiments were conducted under optimal conditions with a viscous, non-acidic oil from Hepler (KS) oil field. The coreflood experiments were conducted with Berea sandstone cores since field core was not available in sufficient quantity for coreflood tests. The Tucker sand of Hepler field is a Class I fluvial dominated deltaic reservoir, as classified by the Department of Energy, which has been selected as the site of a DOE-sponsored field pilot test.

  1. Disk filter

    DOEpatents

    Bergman, Werner

    1986-01-01

    An electric disk filter provides a high efficiency at high temperature. A hollow outer filter of fibrous stainless steel forms the ground electrode. A refractory filter material is placed between the outer electrode and the inner electrically isolated high voltage electrode. Air flows through the outer filter surfaces through the electrified refractory filter media and between the high voltage electrodes and is removed from a space in the high voltage electrode.

  2. Disk filter

    DOEpatents

    Bergman, W.

    1985-01-09

    An electric disk filter provides a high efficiency at high temperature. A hollow outer filter of fibrous stainless steel forms the ground electrode. A refractory filter material is placed between the outer electrode and the inner electrically isolated high voltage electrode. Air flows through the outer filter surfaces through the electrified refractory filter media and between the high voltage electrodes and is removed from a space in the high voltage electrode.

  3. Elution of uranium and transition metals from amidoxime-based polymer adsorbents for sequestering uranium from seawater

    DOE PAGESBeta

    Pan, Horng-Bin; Kuo, Li-Jung; Miyamoto, Naomi; Wood, Jordana; Strivens, Jonathan E.; Gill, Gary; Janke, Christopher James; Wai, Chien

    2015-11-30

    High-surface-area amidoxime and carboxylic acid grafted polymer adsorbents developed at Oak Ridge National Laboratory were tested for sequestering uranium in a flowing seawater flume system at the PNNL-Marine Sciences Laboratory. FTIR spectra indicate that a KOH conditioning process is necessary to remove the proton from the carboxylic acid and make the sorbent effective for sequestering uranium from seawater. The alkaline conditioning process also converts the amidoxime groups to carboxylate groups in the adsorbent. Both Na2CO3 H2O2 and hydrochloric acid elution methods can remove ~95% of the uranium sequestered by the adsorbent after 42 days of exposure in real seawater. Themore » Na2CO3 H2O2 elution method is more selective for uranium than conventional acid elution. Iron and vanadium are the two major transition metals competing with uranium for adsorption to the amidoxime-based adsorbents in real seawater. Tiron (4,5-Dihydroxy-1,3-benzenedisulfonic acid disodium salt, 1 M) can remove iron from the adsorbent very effectively at pH around 7. The coordination between vanadium (V) and amidoxime is also discussed based on our 51V NMR data.« less

  4. Elution of Uranium and Transition Metals from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    SciTech Connect

    Pan, Horng-Bin; Kuo, Li-Jung; Wai, Chien M.; Miyamoto, Naomi; Joshi, Ruma; Wood, Jordana R.; Strivens, Jonathan E.; Janke, Christopher J.; Oyola, Yatsandra; Das, Sadananda; Mayes, Richard T.; Gill, Gary A.

    2015-11-30

    High-surface-area amidoxime and carboxylic acid grafted polymer adsorbents developed at Oak Ridge National Laboratory were tested for sequestering uranium in a flowing seawater flume system at the PNNL-Marine Sciences Laboratory. FTIR spectra indicate that a KOH conditioning process is necessary to remove the proton from the carboxylic acid and make the sorbent effective for sequestering uranium from seawater. The alkaline conditioning process also converts the amidoxime groups to carboxylate groups in the adsorbent. Both Na2CO3-H2O2 and hydrochloric acid elution methods can remove ~95% of the uranium sequestered by the adsorbent after 42 days of exposure in real seawater. The Na2CO3-H2O2 elution method is more selective for uranium than conventional acid elution. Iron and vanadium are the two major transition metals competing with uranium for adsorption to the amidoxime-based adsorbents in real seawater.

  5. Elution of uranium and transition metals from amidoxime-based polymer adsorbents for sequestering uranium from seawater

    SciTech Connect

    Pan, Horng-Bin; Kuo, Li-Jung; Miyamoto, Naomi; Wood, Jordana; Strivens, Jonathan E.; Gill, Gary; Janke, Christopher James; Wai, Chien

    2015-11-30

    High-surface-area amidoxime and carboxylic acid grafted polymer adsorbents developed at Oak Ridge National Laboratory were tested for sequestering uranium in a flowing seawater flume system at the PNNL-Marine Sciences Laboratory. FTIR spectra indicate that a KOH conditioning process is necessary to remove the proton from the carboxylic acid and make the sorbent effective for sequestering uranium from seawater. The alkaline conditioning process also converts the amidoxime groups to carboxylate groups in the adsorbent. Both Na2CO3 H2O2 and hydrochloric acid elution methods can remove ~95% of the uranium sequestered by the adsorbent after 42 days of exposure in real seawater. The Na2CO3 H2O2 elution method is more selective for uranium than conventional acid elution. Iron and vanadium are the two major transition metals competing with uranium for adsorption to the amidoxime-based adsorbents in real seawater. Tiron (4,5-Dihydroxy-1,3-benzenedisulfonic acid disodium salt, 1 M) can remove iron from the adsorbent very effectively at pH around 7. The coordination between vanadium (V) and amidoxime is also discussed based on our 51V NMR data.

  6. The effect of an alendronate-eluting titanium system to induce osteogenic differentiation in human buccal fat cells (HBFCs)

    NASA Astrophysics Data System (ADS)

    Kim, Sung Eun; Lee, Su-Young; Yun, Young-Pil; Lee, Jae Yong; Park, Kyeongsoon; Lee, Deok-Won; Song, Hae-Ryong

    2012-10-01

    The purpose of this study was to develop alendronate (Aln)-eluting Ti substrates to induce osteogenic differentiation of human buccal fat cells (HBFCs). The surface of pristine Ti was modified by dopamine (DOPA) and then heparin was grafted onto the aminated Ti surfaces to achieve the Aln-eluting Ti system. Aln was subsequently immobilized on the surface of heparinized Ti (Hep-Ti). Pristine Ti and surface-modified-Ti were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and contact angle. Osteogenic differentiation of HBFCs on the surface of pristine-Ti, Hep-Ti, Aln (1 mg)/Hep-Ti, and Aln (5 mg)/Hep-Ti was demonstrated by alkaline phosphatase (ALP) activity, calcium deposition, and osteocalcin and osteopontin mRNA expression. Successful immobilization of Aln on Hep-Ti was confirmed by XPS and contact angle. Aln/Hep-Ti showed the sustained release for up to 28 days. Additionally, HBFCs cultured on Aln/Hep-Ti substrates showed significantly induced ALP activity, calcium deposition, and osteocalcin and osteopontin mRNA expression. These results suggest that Aln-eluting Ti substrates have a potential effect on osteogenic differentiation of HBFCs and will be a promising material for bone regeneration.

  7. Concentration of poliovirus from tap water using positively charged microporous filters.

    PubMed Central

    Sobsey, M D; Jones, B L

    1979-01-01

    Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods. PMID:36844

  8. Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial

    PubMed Central

    2014-01-01

    Background Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion. Methods/Design The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged ≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter >4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography. Discussion EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients. Trial registration The trial listed in clinicaltrials.gov as NCT01711931. PMID:24398143

  9. Water Filters

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The Aquaspace H2OME Guardian Water Filter, available through Western Water International, Inc., reduces lead in water supplies. The filter is mounted on the faucet and the filter cartridge is placed in the "dead space" between sink and wall. This filter is one of several new filtration devices using the Aquaspace compound filter media, which combines company developed and NASA technology. Aquaspace filters are used in industrial, commercial, residential, and recreational environments as well as by developing nations where water is highly contaminated.

  10. Alkaline quinone flow battery.

    PubMed

    Lin, Kaixiang; Chen, Qing; Gerhardt, Michael R; Tong, Liuchuan; Kim, Sang Bok; Eisenach, Louise; Valle, Alvaro W; Hardee, David; Gordon, Roy G; Aziz, Michael J; Marshak, Michael P

    2015-09-25

    Storage of photovoltaic and wind electricity in batteries could solve the mismatch problem between the intermittent supply of these renewable resources and variable demand. Flow batteries permit more economical long-duration discharge than solid-electrode batteries by using liquid electrolytes stored outside of the battery. We report an alkaline flow battery based on redox-active organic molecules that are composed entirely of Earth-abundant elements and are nontoxic, nonflammable, and safe for use in residential and commercial environments. The battery operates efficiently with high power density near room temperature. These results demonstrate the stability and performance of redox-active organic molecules in alkaline flow batteries, potentially enabling cost-effective stationary storage of renewable energy. PMID:26404834

  11. PRELIMINARY REPORT ON EVALUATION OF POTENTIAL ELUANTS FOR NON-ACID ELUTION OF CESIUM FROM RESORCINOL-FORMALDEHYDE RESIN

    SciTech Connect

    Adu-Wusu, K.; Pennebaker, F.

    2010-09-01

    Small-column ion exchange (SCIX) units installed in high-level waste tanks to remove Cs-137 from highly alkaline salt solutions are among the waste treatment plans in the DOE-complex. Spherical Resorcinol-Formaldehyde (sRF) is the ion exchange resin selected for use in the Hanford Waste Treatment and Immobilization Plant (WTP). It is also the primary ion exchange material under consideration for SCIX at the Hanford site. The elution step of the multi-step ion exchange process is typically done with 0.5 M nitric acid. An acid eluant is a potential hazard in the event of a spill, leak, etc. because the high-level waste tanks are made of carbon steel. Corrosion and associated structural damage may ensue. Studies are ongoing to explore non-acid elution as an alternative. Batch contact sorption equilibrium screening tests have been conducted with 36 potential non-acid eluants. The sorption tests involve equilibrating each cesium-containing eluant solution with the sRF resin for 48 hours at 25 C in a shaker oven. In the sorption tests, an eluant is deemed to have a high cesium elution potential if it minimizes cesium sorption onto the sRF resin. The top candidates (based on lowest cesium sorption distribution coefficients) include ammonium carbonate, ammonium carbonate/ammonium hydroxide, ammonium bicarbonate, rubidium carbonate, ammonium acetate, ammonium acetate/ammonium hydroxide, ammonium bicarbonate/ammonium hydroxide, calcium chloride, and magnesium chloride. The next phase of testing for this work will focus on the following down selected eluants: Ammonium carbonate, ammonium acetate, calcium acetate, magnesium acetate, nitric acid, and ammonium hydroxide. The next testing phase is a confirmation of the elution ability of the selected eluants. It will mimic a typical sRF cesium ion exchange process i.e., sorption or loading, caustic wash, water rinse, and elution via batch contact sorption and quasi column caustic wash/water rinse/elution. Due to corrosion

  12. Biological Filters.

    ERIC Educational Resources Information Center

    Klemetson, S. L.

    1978-01-01

    Presents the 1978 literature review of wastewater treatment. The review is concerned with biological filters, and it covers: (1) trickling filters; (2) rotating biological contractors; and (3) miscellaneous reactors. A list of 14 references is also presented. (HM)

  13. Metallic Filters

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Filtration technology originated in a mid 1960's NASA study. The results were distributed to the filter industry, an HR Textron responded, using the study as a departure for the development of 421 Filter Media. The HR system is composed of ultrafine steel fibers metallurgically bonded and compressed so that the pore structure is locked in place. The filters are used to filter polyesters, plastics, to remove hydrocarbon streams, etc. Several major companies use the product in chemical applications, pollution control, etc.

  14. Water Filters

    NASA Technical Reports Server (NTRS)

    1987-01-01

    A compact, lightweight electrolytic water filter generates silver ions in concentrations of 50 to 100 parts per billion in the water flow system. Silver ions serve as effective bactericide/deodorizers. Ray Ward requested and received from NASA a technical information package on the Shuttle filter, and used it as basis for his own initial development, a home use filter.

  15. FILTER TREATMENT

    DOEpatents

    Sutton, J.B.; Torrey, J.V.P.

    1958-08-26

    A process is described for reconditioning fused alumina filters which have become clogged by the accretion of bismuth phosphate in the filter pores, The method consists in contacting such filters with faming sulfuric acid, and maintaining such contact for a substantial period of time.

  16. Coronary vasomotion one year after drug-eluting stent implantation: comparison of everolimus-eluting and paclitaxel-eluting coronary stents.

    PubMed

    Hamilos, Michalis; Ribichini, Flavio; Ostojic, Miodrag C; Ferrero, Valeria; Orlic, Dejan; Vassanelli, Corrado; Karanovic, Nevena; Sarno, Giovanna; Cuisset, Thomas; Vardas, Panos E; Wijns, William

    2014-06-01

    First-generation drug-eluting stents (DES) have been associated with impaired localized coronary vasomotion and delayed endothelialization. We aimed to compare coronary vasomotion after implantation of a newer-generation everolimus-eluting stent (EES), with a first-generation paclitaxel-eluting stent (PES). Coronary vasomotion was studied in 19 patients with EES and 13 with PES. Vasomotor response was measured proximally and distally to the stent and in a remote vessel (reference segment). Quantitative coronary angiography was performed offline. Endothelium independent vasomotion did not differ significantly between the two groups. EES showed significant vasodilatation while PES showed vasoconstriction at both proximal (+4.5 ± 3.6 vs -4.2 ± 6.9, p < 0.001) and distal (+4.6 ± 7.9 vs -4.8 ± 9.3, p = 0.003) segments. The reference segment did not show any significant difference in vasodilatation between the two groups (+9.8 ± 6.4 vs +7.2 ± 5.2, p = 0.17). Endothelium-dependent vasomotion at adjacent stent segments is relatively preserved after EES implantation while vasoconstriction was observed after PES implantation. PMID:24794876

  17. Effects of ultrasound and ultrasound assisted alkaline pretreatments on the enzymolysis and structural characteristics of rice protein.

    PubMed

    Li, Suyun; Yang, Xue; Zhang, Yanyan; Ma, Haile; Liang, Qiufang; Qu, Wenjuan; He, Ronghai; Zhou, Cunshan; Mahunu, Gustav Komla

    2016-07-01

    The objectives of this study were to investigate the effects of multi-frequency energy-gathered ultrasound (MFEGU) and MFEGU assisted alkaline pretreatments on the enzymolysis and the mechanism of two pretreatments accelerating the rice protein (RP) proteolysis process. The results showed that MFEGU and MFEGU assisted alkaline pretreatments improved significantly (P<0.05) the degree of hydrolysis (DH) and the protein elution amount of RP. Furthermore under the same DH conditions, ultrasound and ultrasound assisted alkaline pretreatments were more save the enzymolysis time than the unpretreatment. The changes in UV-vis spectra, fluorescence emission spectra indicated unfolding and destruction of RP by MFEGU and MFEGU assisted alkaline pretreatments. The circular dichroism analysis showed that both pretreatments decreased α-helix but increased β-sheet and random coil of RP. Amino acid composition revealed that MFEGU and MFEGU assisted alkaline pretreatments could increase the protein elution amount and the ratio of hydrophobic amino acids. Atomic force microscopy (AFM) indicated that both pretreatments destroyed the microstructures and reduced the particle size of RP. Therefore, MFEGU and MFEGU assisted alkaline pretreatments are beneficial to improving the degree of hydrolysis due to its sonochemistry effect on the molecular conformation as well as on the microstructure of protein. PMID:26964920

  18. Alkaline Phosphatase in Stem Cells

    PubMed Central

    Štefková, Kateřina; Procházková, Jiřina; Pacherník, Jiří

    2015-01-01

    Alkaline phosphatase is an enzyme commonly expressed in almost all living organisms. In humans and other mammals, determinations of the expression and activity of alkaline phosphatase have frequently been used for cell determination in developmental studies and/or within clinical trials. Alkaline phosphatase also seems to be one of the key markers in the identification of pluripotent embryonic stem as well as related cells. However, alkaline phosphatases exist in some isoenzymes and isoforms, which have tissue specific expressions and functions. Here, the role of alkaline phosphatase as a stem cell marker is discussed in detail. First, we briefly summarize contemporary knowledge of mammalian alkaline phosphatases in general. Second, we focus on the known facts of its role in and potential significance for the identification of stem cells. PMID:25767512

  19. Development of a pheromone elution rate physical model

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A first principle modeling approach is applied to available data describing the elution of semiochemicals from pheromone dispensers. These data include field data for 27 products developed by several manufacturers, including homemade devices, as well as laboratory data collected on three semiochemi...

  20. Stent fracture and restenosis of a paclitaxel-eluting stent.

    PubMed

    Hamilos, Michalis I; Papafaklis, Michail I; Ligthart, Jurgen M; Serruys, Patrick W; Sianos, Georgios

    2005-01-01

    We describe the case of a patient with restenosis six months after stent implantation, at two points where stent fracture had occurred. Fracture is an unusual and probably underestimated cause of restenosis, which acquires special significance in this era of drug-eluting stents. PMID:16422133

  1. Early definite stent thrombosis with everolimus-eluting stents

    PubMed Central

    Naito, Ryo; Miyauchi, Katsumi; Konishi, Hirokazu; Tsuboi, Shuta; Okazaki, Shinya; Daida, Hiroyuki

    2015-01-01

    Key Clinical Message Stent thrombosis (ST) is a serious complication of percutaneous coronary intervention. Several factors are associated with ST, and combination of these factors increase the risk, even in everolimus-eluting stents, which have low risk of ST. We experienced a case of ST caused by limited coronary flow and resistance to antiplatelet agent. PMID:26509023

  2. Alkaline fuel cells applications

    NASA Astrophysics Data System (ADS)

    Kordesch, Karl; Hacker, Viktor; Gsellmann, Josef; Cifrain, Martin; Faleschini, Gottfried; Enzinger, Peter; Fankhauser, Robert; Ortner, Markus; Muhr, Michael; Aronson, Robert R.

    On the world-wide automobile market technical developments are increasingly determined by the dramatic restriction on emissions as well as the regimentation of fuel consumption by legislation. Therefore there is an increasing chance of a completely new technology breakthrough if it offers new opportunities, meeting the requirements of resource preservation and emission restrictions. Fuel cell technology offers the possibility to excel in today's motive power techniques in terms of environmental compatibility, consumer's profit, costs of maintenance and efficiency. The key question is economy. This will be decided by the costs of fuel cell systems if they are to be used as power generators for future electric vehicles. The alkaline hydrogen-air fuel cell system with circulating KOH electrolyte and low-cost catalysed carbon electrodes could be a promising alternative. Based on the experiences of Kordesch [K. Kordesch, Brennstoffbatterien, Springer, Wien, 1984, ISBN 3-387-81819-7; K. Kordesch, City car with H 2-air fuel cell and lead-battery, SAE Paper No. 719015, 6th IECEC, 1971], who operated a city car hybrid vehicle on public roads for 3 years in the early 1970s, improved air electrodes plus new variations of the bipolar stack assembly developed in Graz are investigated. Primary fuel choice will be a major issue until such time as cost-effective, on-board hydrogen storage is developed. Ammonia is an interesting option. The whole system, ammonia dissociator plus alkaline fuel cell (AFC), is characterised by a simple design and high efficiency.

  3. Ligand-assisted elution chromatography for separation of lanthanides.

    PubMed

    Ling, Lei; Wang, Nien-Hwa Linda

    2015-04-10

    Lanthanides (Ln's) are the major components of rare earth elements, which are critical components of many high-value products. The ions of adjacent Ln's have the same valence and very similar ionic radii. They cannot be separated using conventional adsorption or ion exchange processes. Current production of high-purity Ln's is based on multiple sequential and parallel solvent extraction processes, which require large amounts of toxic solvents and result in serious negative impact on the environment. In this study, a ligand-assisted elution chromatography process for the separation of Ln's was developed for the first time for titania, which is a robust and inexpensive inorganic sorbent. A selective ligand for Ln's, ethylenediaminetetraacetic acid (EDTA), was found to adsorb on the sorbent. The adsorbed EDTA became strong adsorption sites for the Ln's. Desorption of Ln's was driven by reversible reactions of Ln's with EDTA in the mobile phase. The overall sorbent selectivity for the reaction and adsorption process was approximately equal to the ratio of the sorbent selectivity to the ligand selectivity. The separation mechanisms were tested and verified using rate model simulations and experimental data for the separation of praseodymium (Pr), neodymium (Nd), and samarium (Sm). Simulations based on the model were used to design efficient linear gradient elution and stepwise elution processes. The purity and yield of all three Ln's were found to be above 95% in the designed processes. Stepwise elution can be implemented in a continuous process for increasing sorbent productivity and reducing costs for large-scale separation. Ligand assisted elution processes are much simpler and more environmentally friendly than the conventional solvent extraction processes. PMID:25746756

  4. Nanoporous Titanium Surfaces for Sustained Elution of Proteins and Antibiotics

    PubMed Central

    Cassani, Davide A. D.; Variola, Fabio

    2014-01-01

    Current medically relevant metals for prosthetic reconstructions enjoy a relatively good success rate, but their performance drops significantly in patients with compromised health status, and post-surgical infections still remain an important challenge. To address these problems, different nanotechnology-based strategies have been exploited to create implantable metals with an enhanced bioactivity and antibacterial capacities. Among these, oxidative nanopatterning has emerged as a very effective approach to engender nanoporous surfaces that stimulate and guide the activity of adhering cells. The resulting nanoporosity is also attractive because it offers nanoconfined volumes that can be exploited to load bioactive compounds and modulate their release over time. Such extended elution is needed since a single exposure to growth factors and/or antibiotics, for instance, may not be adequate to further sustain bone regeneration and/or to counteract bacterial colonization. In this article, we assessed the capacities of nanoporous titanium surfaces generated by oxidative nanopatterning to provide controlled and sustained elution of proteins and antibiotic molecules. To this end, we have selected bovine serum albumin (BSA) and vancomycin to reflect commonly used compounds, and investigated their adsorption and elution by Fourier-transform infrared (FT-IR) and ultraviolet–visible (UV-VIS) spectroscopy. Our results demonstrate that while the elution of albumin is not significantly affected by the nanoporosity, in the case of vancomycin, nanoporous surfaces provided an extended release. These findings were successively correlated to the establishment of interactions with the surface and physical-entrapment effects exerted by the nanopores, ultimately highlighting their synergistic contribution to the release profiles and thus their importance in the design of nanostructured eluting platforms for applications in medicine. PMID:24633020

  5. Filtering apparatus

    DOEpatents

    Haldipur, Gaurang B.; Dilmore, William J.

    1992-01-01

    A vertical vessel having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas.

  6. Filtering apparatus

    DOEpatents

    Haldipur, G.B.; Dilmore, W.J.

    1992-09-01

    A vertical vessel is described having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas. 18 figs.

  7. Silica in alkaline brines

    USGS Publications Warehouse

    Jones, B.F.; Rettig, S.L.; Eugster, H.P.

    1967-01-01

    Analysis of sodium carbonate-bicarbonate brines from closed basins in volcanic terranes of Oregon and Kenya reveals silica contents of up to 2700 parts per million at pH's higher than 10. These high concentrations of SiO 2 can be attributed to reaction of waters with silicates, and subsequent evaporative concentration accompanied by a rise in pH. Supersaturation with respect to amorphous silica may occur and persist for brines that are out of contact with silicate muds and undersaturated with respect to trona; correlation of SiO2 with concentration of Na and total CO2 support this interpretation. Addition of moredilute waters to alkaline brines may lower the pH and cause inorganic precipitation of substantial amounts of silica.

  8. Bifunctional alkaline oxygen electrodes

    NASA Technical Reports Server (NTRS)

    Swette, L.; Kackley, N.; Mccatty, S. A.

    1991-01-01

    The authors describe the identification and testing of electrocatalysts and supports for the positive electrode of moderate-temperature, single-unit, rechargeable alkaline fuel cells. Recent work on Na(x)Pt3O4, a potential bifunctional catalyst, is described, as well as the application of novel approaches to the development of more efficient bifunctional electrode structures. The three dual-character electrodes considered here showed similar superior performance; the Pt/RhO2 and Rh/RhO2 electrodes showed slightly better performance than the Pt/IrO2 electrode. It is concluded that Na(x)Pt3O4 continues to be a promising bifunctional oxygen electrode catalyst but requires further investigation and development.

  9. Nanoparticles and drug eluting stents for disease detection and treatment

    NASA Astrophysics Data System (ADS)

    Meng, Juan

    This thesis presents the results of experimental and theoretical studies of nanoparticle entry/adhesion to breast cancer cells and adhesion in drug-eluting stents. Atomic Force Microscopy (AFM) techniques are used to quantify the adhesion. The thermodynamics and kinetics concepts are presented for the modeling of nanoparticle entry into breast cancer cells. In the case of the drug-eluting stents studies, a combination of adhesion theory and fracture mechanics concepts is used to estimate the adhesion energies. To investigate the specific accumulation of the functionalized super-paramagnetic iron oxide nanoparticles (SPIONs) in breast cancer cells, a combination of transmission electron microscopy (TEM) and spectrophotometric analysis was used. It is shown that SPIONs conjugated to luteinizing hormone releasing hormone (LHRH) (LHRH-SPIONs), can be used to specifically target breast cancer cells. They also act as contrast enhancement agents during the magnetic resonance imaging (MRI) of breast cancer xenografts. The adhesion between LHRH and breast cancer cells is an important factor for LHRH-SPIONs to target breast cancer cells. AFM techniques were used to quantify adhesion between LHRH peptides and their receptors on breast cancer cells. The adhesion force between LHRH-coated AFM tips and human breast cancer cells is shown to be about five times greater than that between LHRH-coated AFM tips and normal breast cells. This result also suggests that force microscopy can be used for the specific detection of breast cancer cells. Adhesion and fracture mechanics techniques were used to study the adhesion between the drug eluting layer and Parylene C layer coated onto a model drug-eluting stent. AFM force--displacement measurements were used to quantify the adhesion between the parylene C primer and the drug-eluting layer and the cohesion between the three constituents of the drug-eluting layer. Adhesion theories were then used to relate the measured forces to adhesion

  10. Influence of cell disruption and elution on cellulase release of Clostridium straminisolvens (CSK1).

    PubMed

    Wang, Jungang; Li, Jiajia; Liu, Jinhuan; Hua, Binbin; Wang, Xiaofen; Lv, Yucai; Cao, Yanzhuan; Cui, Zongjun

    2014-05-01

    Clostridium straminisolvens (CSK1) is a novel cellulolytic bacterium isolated from a cellulose-degrading bacterial community MC1. In this study, the influence of the following cell disruption and elution methods on CSK1cellulase release was investigated: (1) freezing-thawing, (2) ultrasonication, (3) elution, (4) freezing-thawing following elution, (5) ultrasonication following elution, and lastly (6) high-pressure homogenization following elution. The activity of the cellulases CMCase, β-glucosidase, Avicelase, FPase, and xylanase in crude extracts increased 81.5, 23.8, 87.7, 46.3, and 51.7 %, respectively, with an observed optimal treatment method for each cellulase type. The release of protein from CSK1 cells increased following either cell disruption or elution and was highest at 88.3 % in the homogenization high pressure following elution treatment. A newly observed protein was present following cell elution. The performance of cell elution as determined by real time-PCR indicated that the first time cell elution removed more than 90 % of the CSK1 cells from the substrate. These findings demonstrate that cell disruption and elution are effective methods for inducing cellulase release, and elution is the key step for CSK1. To our knowledge, this study presents the first evidence of optimal treatments for induction of cellulase release of Clostridium straminisolvens. This information will be of great value for use in subsequent efforts to better understand the cellulase characteristics of CSK1 and cellulose degradation mechanisms of the MC1 community. PMID:24728761

  11. A case of early drug-eluting stent fracture.

    PubMed

    Smaldone, Costantino; Bacà, Marco; Niccoli, Giampaolo

    2010-10-01

    Although stent fracture following femoro-popliteal intervention is well recognized, coronary stent fracture represents an underrecognized entity. Its incidence is low but it represents an important clinical entity as it may complicate with stent thrombosis causing acute coronary syndromes, or may predispose to instent restenosis. Although coronary stent fracture may involve both bare metal stents (BMS) and drug-eluting stents (DES), a recent analysis of the literature indicates that reports of stent fracture have increased since DES was introduced. Furthermore, chronic stretch at specific vessel sites as bends may lead to late occurrence of fracture. We present the case of a patient with a non-ST-segment elevation acute coronary syndrome caused by the early fracture of an everolimus-eluting stent (Xience®) implanted only three days before. PMID:20944195

  12. Suppression of scarring in peripheral nerve implants by drug elution

    NASA Astrophysics Data System (ADS)

    FitzGerald, James J.

    2016-04-01

    Objective. Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Approach. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. Main results. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Significance. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  13. [Coronary aneurysm after drug-eluting stent implantation].

    PubMed

    Paulista, Paulo Paredes; Paulista, Paulo Henrique Dágola; Centemero, Marinella Patrizia; Feres, Fausto

    2008-01-01

    The use of drug-eluting stents aiming at by-pass the disadvantage of stainless steel stents have been associated to late thrombosis after withdrawal of anti-platelet agents. We report a case with another complication, the development of a coronary aneurysm in the stent area more than three years after index procedure. Late chronic local inflammatory responses may be responsible for the weakening, erosion and aneusrysm formation. PMID:18719840

  14. Fully bioresorbable drug-eluting coronary scaffolds: A review.

    PubMed

    Charpentier, Emmanuel; Barna, Alexandre; Guillevin, Loïc; Juliard, Jean-Michel

    2015-01-01

    Following the development of stents, then drug-eluting stents (DES), bioresorbable scaffolds are proposed as a third evolution in coronary angioplasty, aiming to reduce the incidence of restenosis and stent thrombosis and to restore vascular physiology. At least 16 such devices are currently under development, but published clinical data were available for only three of them in September 2014. The first device is Abbott's BVS(®), a poly-L-lactic acid (PLLA)-based everolimus-eluting device, which has been tested in a registry and two non-randomized trials. Clinical results seem close to what is expected from a modern DES, but possibly with more post-procedural side-effects. Two randomized trials versus DES are underway. This device is already marketed in many European countries. The second device is Elixir's DESolve(®), a PLLA-based novolimus-eluting device, which has been evaluated in two single-arm trials. Results are not widely different from those expected from a DES. The third device is Biotronik's DREAMS(®), a metallic magnesium-based paclitaxel-eluting device, which has been assessed in an encouraging single-arm trial; its second version is currently undergoing evaluation in a single-arm trial. The available results suggest that the technological and clinical development of bioresorbable scaffolds is not yet complete: their possible clinical benefits are still unclear compared with third-generation DES; the impact of arterial physiology restoration has to be assessed over the long term; and their cost-effectiveness has to be established. From the perspective of a health technology assessment, there is no compelling reason to hasten the clinical use of these devices before the results of ongoing randomized controlled trials become available. PMID:26113479

  15. Advances with polymer-free amphilimus-eluting stents.

    PubMed

    CARRIé, Didier

    2016-06-01

    Despite the improved clinical outcomes following the availability of second generation drug eluting stents (DES), percutaneous coronary intervention (PCI) is associated with worse clinical and angiographic outcomes among the patients with diabetes mellitus (DM) than among non-diabetics. The Cre8 Amphilimus-eluting DES is polymer-free, resulting in a reduced inflammatory response and lower risk of stent thrombosis. In a clinical study, it showed equivalent efficacy and safety in diabetic and non-diabetic populations, a unique finding among DES studies. These findings were confirmed in a real-world study, Investig8, and another real-world study, Particip8, is ongoing. The RESERVOIR Clinical Trial recruited patients with DM and showed noninferiority of the Cre8 DES compared to an everolimus eluting DES (EES) in the overall group but showed a statistical superiority of Cre8 in diabetic patients with higher metabolic dysfunctions. The Cre8 DES is therefore a valuable option for this important patient population. PMID:26934663

  16. Modulators of intestinal alkaline phosphatase.

    PubMed

    Bobkova, Ekaterina V; Kiffer-Moreira, Tina; Sergienko, Eduard A

    2013-01-01

    Small molecule modulators of phosphatases can lead to clinically useful drugs and serve as invaluable tools to study functional roles of various phosphatases in vivo. Here, we describe lead discovery strategies for identification of inhibitors and activators of intestinal alkaline phosphatases. To identify isozyme-selective inhibitors and activators of the human and mouse intestinal alkaline phosphatases, ultrahigh throughput chemiluminescent assays, utilizing CDP-Star as a substrate, were developed for murine intestinal alkaline phosphatase (mIAP), human intestinal alkaline phosphatase (hIAP), human placental alkaline phosphatase (PLAP), and human tissue-nonspecific alkaline phosphatase (TNAP) isozymes. Using these 1,536-well assays, concurrent HTS screens of the MLSMR library of 323,000 compounds were conducted for human and mouse IAP isozymes monitoring both inhibition and activation. This parallel screening approach led to identification of a novel inhibitory scaffold selective for murine intestinal alkaline phosphatase. SAR efforts based on parallel testing of analogs against different AP isozymes generated a potent inhibitor of the murine IAP with IC50 of 540 nM, at least 65-fold selectivity against human TNAP, and >185 selectivity against human PLAP. PMID:23860652

  17. Alkaline battery, separator therefore

    NASA Technical Reports Server (NTRS)

    Schmidt, George F. (Inventor)

    1980-01-01

    An improved battery separator for alkaline battery cells has low resistance to electrolyte ion transfer and high resistance to electrode ion transfer. The separator is formed by applying an improved coating to an electrolyte absorber. The absorber, preferably, is a flexible, fibrous, and porous substrate that is resistant to strong alkali and oxidation. The coating composition includes an admixture of a polymeric binder, a hydrolyzable polymeric ester and inert fillers. The coating composition is substantially free of reactive fillers and plasticizers commonly employed as porosity promoting agents in separator coatings. When the separator is immersed in electrolyte, the polymeric ester of the film coating reacts with the electrolyte forming a salt and an alcohol. The alcohol goes into solution with the electrolyte while the salt imbibes electrolyte into the coating composition. When the salt is formed, it expands the polymeric chains of the binder to provide a film coating substantially permeable to electrolyte ion transfer but relatively impermeable to electrode ion transfer during use.

  18. Evaluation of Alkaline Cleaner Materials

    NASA Technical Reports Server (NTRS)

    Partz, Earl

    1998-01-01

    Alkaline cleaners used to process aluminum substrates have contained chromium as the corrosion inhibitor. Chromium is a hazardous substance whose use and control are described by environmental laws. Replacement materials that have the characteristics of chromated alkaline cleaners need to be found that address both the cleaning requirements and environmental impacts. This report will review environmentally friendly candidates evaluated as non-chromium alkaline cleaner replacements and methods used to compare those candidates one versus another. The report will also list characteristics used to select candidates based on their declared contents. It will also describe and evaluate methods used to discriminate among the large number of prospective candidates.

  19. Metal elution from Ni- and Fe-based alloy reactors under hydrothermal conditions.

    PubMed

    Faisal, Muhammad; Quitain, Armando T; Urano, Shin-Ya; Daimon, Hiroyuki; Fujie, Koichi

    2004-05-20

    Elution of metals from Ni- and Fe-based alloy (i.e. Inconel 625 and SUS 316) under hydrothermal conditions was investigated. Results showed that metals could be eluted even in a short contact time. At subcritical conditions, a significant amount of Cr was extracted from SUS 316, while only traces of Ni, Fe, Mo, and Mn were eluted. In contrast, Ni was removed in significant amounts compared to Cr when Inconel 625 was tested. Several factors including temperature and contact time were found to affect elution behavior. The presence of air in the fluid even promoted elution under subcritical conditions. PMID:15120875

  20. WE-G-BRE-08: Radiosensitization by Olaparib Eluting Nanospheres

    SciTech Connect

    Tangutoori, S; Kumar, R; Sridhar, S; Korideck, H; Makrigiorgos, G; Cormack, R

    2014-06-15

    Purpose: Permanent prostate brachytherapy often uses inert bio-absorbable spacers to achieve the desired geometric distribution of sources within the prostate. Transforming these spacers into implantable nanoplatforms for chemo-radiation therapy (INCeRT) provides a means of providing sustained in-situ release of radiosensitizers in the prostate to enhance the therapeutic ratio of the procedure. Olaparib, a PARP inhibitor, suppresses DNA repair processes present during low dose rate continuous irradiation. This work investigates the radiosensitizing/DNA damage repair inhibition by NanoOlaparib eluting nanospheres. Methods: Human cell line PC3 (from ATCC), was maintained in F12-k medium supplemented with fetal bovine serum. Clonogenic assay kit (from Fischer Scientific) was used to fix and stain the cells to determine the long term effects of irradiation. Nanoparticle size and zeta potential of nanospheres were determined using a Zeta particle size analyzer. The incorporation of Olaparib in nanospheres was evaluated by HPLC. Irradiation was performed in a small animal irradiator operating at 220 KeV.The long term effects of radio-sensitization with olaparib and nanoolaparib was determined using the clonogenic assay at 2 Gy and 4 Gy doses. The cells were allowed to grow for around 10 doubling cycles, The colonies were fixed and stained using clonogenic assay kit. The excess stain was washed off using DI water and the images were taken using a digital camera. Results: Radiosensitization studies were carried out in prostate cancer cell line, PC3 radiation at 0, 2 and 4Gy doses. Strongest dose response was observed with nanoolaparib treated cells compared to untreated cells. Conclusion: A two stage drug release of drug eluting nanospheres from a biodegradable spacer has been suggested for sustained in-situ release of Olaparib to suppress DNA repair processes during prostate brachytherapy. The Olaparib eluting nanospheres had the same in-vitro radiosensitizing effect as

  1. Optimization of Drug Delivery by Drug-Eluting Stents

    PubMed Central

    Bozsak, Franz; Gonzalez-Rodriguez, David; Sternberger, Zachary; Belitz, Paul; Bewley, Thomas; Chomaz, Jean-Marc; Barakat, Abdul I.

    2015-01-01

    Drug-eluting stents (DES), which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours) or very slowly (over periods of several months up to one year) at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices. PMID:26083626

  2. Humic acid interference with virus recovery by electropositive microporous filters.

    PubMed Central

    Guttman-Bass, N; Catalano-Sherman, J

    1986-01-01

    The effects of humic acid on poliovirus type 1 recovery from water by Zeta Plus 60S filters were investigated. The humic acid interfered by preventing virus adsorption to the filters, and the interference increased as a function of the amount of humic acid filtered. Humic acid decreased virus adsorption when filtered before the virus, but did not elute virus which had adsorbed to the filters. The effects on virus recovery were not due to alterations in virus titer or neutralizability. The addition of AlCl3, which improved virus recovery by electronegative filters in the presence of humic acid, did not aid in overall virus recovery by the Zeta Plus filters in the presence or absence of humic acid. However, the salt and humic acid in combination improved virus adsorption and concurrently reduced virus elution efficiency. The addition of NaH2PO4 had no direct effect on virus recovery and did not alter the effect of humic acid. In an attempt to identify the components of humic acid responsible for the interference, humic materials were fractionated by size by using Sephadex gel chromatography and dialysis, and the fractions were tested for interfering activity. Interference was not associated with specific size fractions of the humic materials. PMID:3021058

  3. The alkaline and alkaline-carbonatite magmatism from Southern Brazil

    NASA Astrophysics Data System (ADS)

    Ruberti, E.; Gomes, C. D. B.; Comin-Chiaramonti, P.

    2015-12-01

    Early to Late Cretaceous lasting to Paleocene alkaline magmatism from southern Brazil is found associated with major extensional structural features in and around the Paraná Basin and grouped into various provinces on the basis of several data. Magmatism is variable in size, mode of occurrence and composition. The alkaline rocks are dominantly potassic, a few occurrences showing sodic affinity. The more abundant silicate rocks are evolved undersaturated to saturated in silica syenites, displaying large variation in igneous forms. Less evolved types are restricted to subvolcanic environments and outcrops of effusive suites occur rarely. Cumulatic mafic and ultramafic rock types are very common, particularly in the alkali-carbonatitic complexes. Carbonatite bodies are represented by Ca-carbonatites and Mg-carbonatites and more scarcely by Fe-carbonatites. Available radiometric ages for the alkaline rocks fit on three main chronological groups: around 130 Ma, subcoveal with the Early Cretaceous flood tholeiites of the Paraná Basin, 100-110 Ma and 80-90 Ma (Late Cretaceous). The alkaline magmatism also extends into Paleocene times, as indicated by ages from some volcanic lavas. Geochemically, alkaline potassic and sodic rock types are distinguished by their negative and positive Nb-Ta anomalies, respectively. Negative spikes in Nb-Ta are also a feature common to the associated tholeiitic rocks. Sr-Nd-Pb systematics confirm the contribution of both HIMU and EMI mantle components in the formation of the alkaline rocks. Notably, Early and Late Cretaceous carbonatites have the same isotopic Sr-Nd initial ratios of the associated alkaline rocks. C-O isotopic Sr-Nd isotopic ratios indicate typical mantle signature for some carbonatites and the influence of post-magmatic processes in others. Immiscibility of liquids of phonolitic composition, derived from mafic alkaline parental magmas, has been responsible for the origin of the carbonatites. Close association of alkaline

  4. Cost-Effectiveness Analysis of Infrapopliteal Drug-Eluting Stents

    SciTech Connect

    Katsanos, Konstantinos Karnabatidis, Dimitris; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Siablis, Dimitris

    2013-02-15

    IntroductionThere are no cost-utility data about below-the-knee placement of drug-eluting stents. The authors determined the cost-effectiveness of infrapopliteal drug-eluting stents for critical limb ischemia (CLI) treatment. The event-free individual survival outcomes defined by the absence of any major events, including death, major amputation, and target limb repeat procedures, were reconstructed on the basis of two published infrapopliteal series. The first included spot Bail-out use of Sirolimus-eluting stents versus bare metal stents after suboptimal balloon angioplasty (Bail-out SES).The second was full-lesion Primary Everolimus-eluting stenting versus plain balloon angioplasty and bail-out bare metal stenting as necessary (primary EES). The number-needed-to-treat (NNT) to avoid one major event and incremental cost-effectiveness ratios (ICERs) were calculated for a 3-year postprocedural period for both strategies. Overall event-free survival was significantly improved in both strategies (hazard ratio (HR) [confidence interval (CI)]: 0.68 [0.41-1.12] in Bail-out SES and HR [CI]: 0.53 [0.29-0.99] in Primary EES). Event-free survival gain per patient was 0.89 (range, 0.11-3.0) years in Bail-out SES with an NNT of 4.6 (CI: 2.5-25.6) and a corresponding ICER of 6,518 Euro-Sign (range 1,685-10,112 Euro-Sign ). Survival gain was 0.91 (range 0.25-3.0) years in Primary EES with an NNT of 2.7 (CI: 1.7-5.8) and an ICER of 11,581 Euro-Sign (range, 4,945-21,428 Euro-Sign ) per event-free life-year gained. Two-way sensitivity analysis showed that stented lesion length >10 cm and/or DES list price >1000 Euro-Sign were associated with the least economically favorable scenario in both strategies. Both strategies of bail-out SES and primary EES placement in the infrapopliteal arteries for CLI treatment exhibit single-digit NNT and relatively low corresponding ICERs.

  5. A fractured sirolimus-eluting stent with a coronary aneurysm.

    PubMed

    Kim, Sung Hea; Kim, Hyun Joong; Han, Seong Woo; Jung, Sang Man; Kim, Jun Suk; Chee, Hyun Keun; Ryu, Kyu Hyung

    2009-08-01

    A 55-year-old man had undergone successful percutaneous intervention with a sirolimus-eluting stent, placed in the right coronary artery (2.5 x 33 mm) and distal left circumflex artery (3.0 x 28 mm) without high pressure ballooning. Twelve months later he presented with unstable angina. Angiography revealed two fracture sites on the right coronary artery-deployed stent, with a large aneurysm and an aneurysmal dilatation of the left circumflex artery without stent fracture. Due to the potential risk of aneurysmal rupture, he underwent coronary artery bypass grafting and ligation of the aneurysm. PMID:19632438

  6. [DNA degradation during standard alkaline of thermal denaturation].

    PubMed

    Drozhdeniuk, A P; Sulimova, G E; Vaniushin, B F

    1976-01-01

    Essential degradation 8 DNA (up to 10 per cent) with liberation of acid-soluble fragments takes place on the standard alkaline (0,01 M sodium phosphate, pH 12, 60 degrees, 15 min) or thermal (0.06 M sodium phosphate buffer, pH 6.8, 102 degrees C, 15 min) denaturation. This degradation is more or less selective: fraction of low molecular weight fragments, isolated by hydroxyapatite cromatography and eluted by 0.06 M sodium phosphate buffer, pH 6.8 is rich in adenine and thymine and contains about 2 times less 5-methylcytosine than the total wheat germ DNA. The degree of degradation of DNA on thermal denaturation is higher than on alkaline degradation. Therefore while studying reassociation of various DNA, one and the same standard method of DNA denaturation should be used. Besides, both the level of DNA degradation and the nature of the resulting products (fragments) should be taken into account. PMID:999984

  7. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.

    PubMed

    Parsa, Ehsan; Saroukhani, Sepideh; Majlessi, Fereshteh; Poorhosseini, Hamidreza; Lofti-Tokaldany, Masoumeh; Jalali, Arash; Salarifar, Mojtaba; Nematipour, Ebrahim; Alidoosti, Mohammad; Aghajani, Hassan; Amirzadegan, Alireza; Kassaian, Seyed Ebrahim

    2016-04-01

    We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent. PMID:27127426

  8. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study

    PubMed Central

    Parsa, Ehsan; Saroukhani, Sepideh; Majlessi, Fereshteh; Poorhosseini, Hamidreza; Lofti-Tokaldany, Masoumeh; Jalali, Arash; Salarifar, Mojtaba; Nematipour, Ebrahim; Alidoosti, Mohammad; Aghajani, Hassan; Amirzadegan, Alireza

    2016-01-01

    We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421–1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent. PMID:27127426

  9. Mathematical modeling of cross-linking monomer elution from resin-based dental composites.

    PubMed

    Manojlovic, Dragica; Radisic, Marina; Lausevic, Mila; Zivkovic, Slavoljub; Miletic, Vesna

    2013-01-01

    Elution of potentially toxic substances, including monomers, from resin-based dental composites may affect the biocompatibility of these materials in clinical conditions. In addition to the amounts of eluted monomers, mathematical modeling of elution kinetics reveals composite restorations as potential chronic sources of leachable monomers. The aim of this work was to experimentally quantify elution of main cross-linking monomers from four commercial composites and offer a mathematical model of elution kinetics. Composite samples (n = 7 per group) of Filtek Supreme XT (3M ESPE), Tetric EvoCeram (Ivoclar Vivadent), Admira (Voco), and Filtek Z250 (3M ESPE) were prepared in 2-mm thick Teflon moulds and cured with halogen or light-emitting diode light. Monomer elution in ethanol and water was analyzed using high-performance liquid chromatography up to 28 days postimmersion. The mathematical model was expressed as a sum of two exponential regression functions representing the first-order kinetics law. Elution kinetics in all cases followed the same mathematical model though differences in rate constants as well as the extent of monomer elution were material-, LCU-, medium-dependent. The proposed mechanisms of elution indicate fast elution from surface and subsurface layers and up to 100 times slower monomer extraction from the bulk polymer. PMID:22997145

  10. Water Filters

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Seeking to find a more effective method of filtering potable water that was highly contaminated, Mike Pedersen, founder of Western Water International, learned that NASA had conducted extensive research in methods of purifying water on board manned spacecraft. The key is Aquaspace Compound, a proprietary WWI formula that scientifically blends various types of glandular activated charcoal with other active and inert ingredients. Aquaspace systems remove some substances; chlorine, by atomic adsorption, other types of organic chemicals by mechanical filtration and still others by catalytic reaction. Aquaspace filters are finding wide acceptance in industrial, commercial, residential and recreational applications in the U.S. and abroad.

  11. Numerical modeling of elution peak profiles in supercritical fluid chromatography. Part I-Elution of an unretained tracer

    SciTech Connect

    Kaczmarski, Krzysztof; Guiochon, Georges A

    2010-01-01

    When chromatography is carried out with high-density carbon dioxide as the main component of the mobile phase (a method generally known as 'supercritical fluid chromatography' or SFC), the required pressure gradient along the column is moderate. However, this mobile phase is highly compressible and, under certain experimental conditions, its density may decrease significantly along the column. Such an expansion absorbs heat, cooling the column, which absorbs heat from the outside. The resulting heat transfer causes the formation of axial and radial gradients of temperature that may become large under certain conditions. Due to these gradients, the mobile phase velocity and most physico-chemical parameters of the system (viscosity, diffusion coefficients, etc.) are no longer constant throughout the column, resulting in a loss of column efficiency, even at low flow rates. At high flow rates and in serious cases, systematic variations of the retention factors and the separation factors with increasing flow rates and important deformations of the elution profiles of all sample components may occur. The model previously used to account satisfactorily for the effects of the viscous friction heating of the mobile phase in HPLC is adapted here to account for the expansion cooling of the mobile phase in SFC and is applied to the modeling of the elution peak profiles of an unretained compound in SFC. The numerical solution of the combined heat and mass balance equations provides temperature and pressure profiles inside the column, and values of the retention time and efficiency for elution of this unretained compound that are in excellent agreement with independent experimental data.

  12. Drug-Eluting Fibers for HIV-1 Inhibition and Contraception

    PubMed Central

    Ball, Cameron; Krogstad, Emily; Chaowanachan, Thanyanan; Woodrow, Kim A.

    2012-01-01

    Multipurpose prevention technologies (MPTs) that simultaneously prevent sexually transmitted infections (STIs) and unintended pregnancy are a global health priority. Combining chemical and physical barriers offers the greatest potential to design effective MPTs, but integrating both functional modalities into a single device has been challenging. Here we show that drug-eluting fiber meshes designed for topical drug delivery can function as a combination chemical and physical barrier MPT. Using FDA-approved polymers, we fabricated nanofiber meshes with tunable fiber size and controlled degradation kinetics that facilitate simultaneous release of multiple agents against HIV-1, HSV-2, and sperm. We observed that drug-loaded meshes inhibited HIV-1 infection in vitro and physically obstructed sperm penetration. Furthermore, we report on a previously unknown activity of glycerol monolaurate (GML) to potently inhibit sperm motility and viability. The application of drug-eluting nanofibers for HIV-1 prevention and sperm inhibition may serve as an innovative platform technology for drug delivery to the lower female reproductive tract. PMID:23209601

  13. Corrosion of mild steel in simulated cesium elution process solutions

    SciTech Connect

    Elmore, M.R.

    1996-09-01

    The West Valley Support Project is being conducted to meet technology needs for the West Valley Demonstration Project and to provide support to the site cleanup and stabilization activities, which involves removing residual Cs in Tank 8D-1 after waste retrieval. In-tank oxalic acid elution of Cs-loaded zeolite is being evaluated. The work reported here involved evaluating the potential for increased corrosion of Tank 8D-1 during Cs elution, because oxalic acid is corrosive to carbon steel. This included corrosion tests with mild steel (A516 Grade 55) at 27-50 C with 4 and 8 wt% oxalic acid, for 2, 4, and 6 days. Results agreed with Sept. 1995 tests at 50 C for 1-3 weeks. Corrosion rate of A516 Grade 55 mild steel in oxalic acid is quite high (about 150 mils/y or 3.8 mm/y). Corrosion increased three- or fourfold going from 27 to 50 C. Although the tests resulted in a very rough surface appearance, indicating potential for localized corrosion, eg, pitting and crevice corrosion, the exposure times used were apparently too short to initiate pitting.

  14. Drug-eluting fibers for HIV-1 inhibition and contraception.

    PubMed

    Ball, Cameron; Krogstad, Emily; Chaowanachan, Thanyanan; Woodrow, Kim A

    2012-01-01

    Multipurpose prevention technologies (MPTs) that simultaneously prevent sexually transmitted infections (STIs) and unintended pregnancy are a global health priority. Combining chemical and physical barriers offers the greatest potential to design effective MPTs, but integrating both functional modalities into a single device has been challenging. Here we show that drug-eluting fiber meshes designed for topical drug delivery can function as a combination chemical and physical barrier MPT. Using FDA-approved polymers, we fabricated nanofiber meshes with tunable fiber size and controlled degradation kinetics that facilitate simultaneous release of multiple agents against HIV-1, HSV-2, and sperm. We observed that drug-loaded meshes inhibited HIV-1 infection in vitro and physically obstructed sperm penetration. Furthermore, we report on a previously unknown activity of glycerol monolaurate (GML) to potently inhibit sperm motility and viability. The application of drug-eluting nanofibers for HIV-1 prevention and sperm inhibition may serve as an innovative platform technology for drug delivery to the lower female reproductive tract. PMID:23209601

  15. Precision control of eluted activity from a Sr/Rb generator for cardiac positron emission tomography.

    PubMed

    Klein, R; Adler, A; Beanlands, R S; deKemp, R A

    2004-01-01

    A rubidium-82 (/sup 82/Rb) elution system is described for use with clinical positron emission tomography. The system is self-calibrating with 1.4% repeatability, independent of generator activity and elution flow rate. Saline flow is switched between a /sup 82/Sr//sup 82/Rb generator and a bypass line to achieve a constant activity elution of /sup 82/Rb. In the present study, pulse width modulation (PWM) of a solenoid valve is compared to simple threshold control as a means to simulate a proportional valve. A predictive-corrective control algorithm is developed which produces a constant activity elution within the constraints of long feedback delay and short elution time. Accurate constant-activity elutions of 10-70% of the total generator activity were demonstrated using the threshold comparison control. The adaptive-corrective control of the PWM valve provided a substantial improvement in precision of the steady-state output. PMID:17271953

  16. Multiple Stent Fractures After Everolimus-Eluting Stent Implantation Causing Acute Myocardial Infarction

    PubMed Central

    Ji, Eun Young; Park, Gyung-Min; Kim, Dae Won; Kim, Tae-Seok; Kim, Chan Joon; Cho, Jung Sun; Park, Mahn-Won; Her, Sung Ho

    2016-01-01

    Abstract Stent fracture is an uncommon complication of drug-eluting stent implantation, but it has a clinical significance because of its potential association with adverse cardiac events such as in-stent restenosis, target lesion revascularization, and stent thrombosis. Multiple stent fractures account for a small proportion, but they may lead to more serious complications. Newer generation drug-eluting stents are designed for improved safety and efficacy compared with early generation drug-eluting stents. Multiple stent fractures after newer generation drug-eluting stent implantation are a rare case. We report a case of 25-year-old male who presented with acute myocardial infarction caused by multiple stent fractures after everolimus-eluting stents implantation and was treated by balloon angioplasty. Physicians should be aware of the possibility of multiple stent fractures even after newer generation drug-eluting stent implantation. PMID:26871806

  17. Tissue Integration of Growth Factor-Eluting Layer-by-Layer Polyelectrolyte Multilayer Coated Implants

    PubMed Central

    Macdonald, Mara L.; Samuel, Raymond E.; Shah, Nisarg J.; Padera, Robert; Beben, Yvette M.; Hammond, Paula T.

    2011-01-01

    Drug eluting coatings that can direct the host tissue response to implanted medical devices have the potential to ameliorate both the medical and financial burden of complications from implantation. However, because many drugs useful in this arena are biologic in nature, a paucity of delivery strategies for biologics, including growth factors, currently limits the control that can be exerted on the implantation environment. Layer-by-Layer (LbL) polyelectrolyte multilayer films are highly attractive as ultrathin biologic reservoirs, due to conformal coating of difficult geometries, aqueous processing likely to preserve fragile protein function, and tenability of incorporation and release profiles. Herein, we describe the first LbL films capable of microgram-scale release of the biologic Bone Morphogenetic Protein 2 (BMP-2), which is capable of directing the host tissue response to create bone from native progenitor cells. Ten micrograms of BMP-2 are released over a period of two weeks in vitro; less than 1% is released in the first 3 hours (compared with commercial collagen matrices which can release up to 60% of BMP-2, too quickly to induce differentiation). BMP-2 released from LbL films retains its ability to induce bone differentiation in MC3T3 E1S4 preosteoblasts, as measured by induction of alkaline phosphatase and stains for calcium (via Alizarin Red) and calcium matrix (via Von Kossa). In vivo, BMP-2 film coated scaffolds were compared with film coated scaffolds lacking BMP-2. BMP-2 coatings implanted intramuscularly were able to initiate host progenitor cells to differentiate into bone, which matured and expanded from four to nine weeks as measured by MicroCT and histology. Such LbL films represent new steps towards controlling and tuning host response to implanted medical devices, which may ultimately increase the success of implanted devices, provide alternative new approaches toward bone wound healing, and lay the foundation for development of a multi

  18. A chelating ion exchanger for gallium recovery from alkaline solution using 5-palmitoyl-8-hydroxyquinoline immobilized on a nonpolar adsorbent

    SciTech Connect

    Filik, H.; Apak, R.

    1998-06-01

    The recently developed method of gallium recovery from alkaline solution by alkanoyl oxine/chloroform extraction has been improved by immobilizing palmitoyl oxine on hydrophobic macroporous styrene-divinylbenzene copolymer Amberlite XAD-2 and passing the GA-containing alkaline solution of pH 13.5 through the synthesized resin column. The developed column showed reasonable efficiency after successive passages, and the selectivity of Ga over Al was very high, suggesting the utilizibility of the method in Ga recovery from the basic aluminate liquor of the Bayer process. The Ga capacity of the oxine-based resin was 3.94 {micro}mol/g. Two mg Ga retained on 10 g resin could be eluted with 25 mL of 2 N HCl at a throughput rate of 2 mL/min. The developed process has prospective use in Ga separation from Al in a strongly alkaline solution.

  19. Water Filter

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A compact, lightweight electrolytic water sterilizer available through Ambassador Marketing, generates silver ions in concentrations of 50 to 100 parts per billion in water flow system. The silver ions serve as an effective bactericide/deodorizer. Tap water passes through filtering element of silver that has been chemically plated onto activated carbon. The silver inhibits bacterial growth and the activated carbon removes objectionable tastes and odors caused by addition of chlorine and other chemicals in municipal water supply. The three models available are a kitchen unit, a "Tourister" unit for portable use while traveling and a refrigerator unit that attaches to the ice cube water line. A filter will treat 5,000 to 10,000 gallons of water.

  20. Eyeglass Filters

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Biomedical Optical Company of America's suntiger lenses eliminate more than 99% of harmful light wavelengths. NASA derived lenses make scenes more vivid in color and also increase the wearer's visual acuity. Distant objects, even on hazy days, appear crisp and clear; mountains seem closer, glare is greatly reduced, clouds stand out. Daytime use protects the retina from bleaching in bright light, thus improving night vision. Filtering helps prevent a variety of eye disorders, in particular cataracts and age related macular degeneration.

  1. Neoatherosclerosis after Drug-Eluting Stent Implantation: Roles and Mechanisms

    PubMed Central

    Cui, Yuanyuan; Shi, Dazhuo; Chen, Keji

    2016-01-01

    In-stent neoatherosclerosis (NA), characterized by a relatively thin fibrous cap and large volume of yellow-lipid accumulation after drug-eluting stents (DES) implantation, has attracted much attention owing to its close relationship with late complications, such as revascularization and late stent thrombosis (ST). Accumulating evidence has demonstrated that more than one-third of patients with first-generation DES present with NA. Even in the advent of second-generation DES, NA still occurs. It is indicated that endothelial dysfunction induced by DES plays a critical role in neoatherosclerotic development. Upregulation of reactive oxygen species (ROS) induced by DES implantation significantly affects endothelial cells healing and functioning, therefore rendering NA formation. In light of the role of ROS in suppression of endothelial healing, combining antioxidant therapies with stenting technology may facilitate reestablishing a functioning endothelium to improve clinical outcome for patients with stenting.

  2. Drug-eluting stents to prevent reblockage of coronary arteries.

    PubMed

    Schwertz, Dorie W; Vaitkus, Paul

    2003-01-01

    Restenosis limits the success of percutaneous transluminal coronary interventions. Coronary artery stenting decreases restenosis, improves outcomes, and is currently the most commonly used percutaneous coronary intervention in the United States. However, in-stent restenosis continues to occur at an unacceptable rate. In-stent restenosis is a neointimal hyperplastic response resulting primarily from vascular smooth muscle cell proliferation. Treatment with anti-proliferative agents presents a logical approach to eradicating restenosis, however, these drugs are highly toxic. Coating stents with anti-proliferative agents allows local delivery of high doses and avoids systemic side effects. In 2001, the results of two clinical trials, RAVEL and ELUTES, using sirolimus- and paclitaxil-coated stents demonstrated nearly complete elimination of in-stent restenosis. These dramatic results represent a tremendous advance in the treatment of coronary heart disease. PMID:12537084

  3. Drug-eluting stents to prevent stent thrombosis and restenosis.

    PubMed

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described. PMID:26567863

  4. Microfluidic Fabrication of MEAN-Eluting Magnetic Microspheres

    PubMed Central

    Kim, Dong-Hyun; Choy, Terence; Huang, Sui; Green, Richard M; Omary, Reed A.; Larson, Andrew C.

    2014-01-01

    Recently, 6-methoxyethylamino numonafide (MEAN) exhibited potent inhibition of hepatocellular carcinoma (HCC) cell growth and less systemic toxicity than amonafide. MEAN may serve as an ideal candidate for the treatment of HCC; however, liver-directed, selective infusion methods may be critical to maximize MEAN dose delivered to the targeted tumors. Our study describes the microfluidic fabrication of MEAN-eluting ultrasmall superparamagnetic iron oxide (USPIO) nanocluster-containing alginate microspheres (MEAN-magnetic microspheres) intended for selective transcatheter delivery to hepatocellular carcinoma. The resulting drug delivery platform was mono-disperse, microsphere sizes were readily controlled based upon channel flow rates during synthesis procedures, and drug release rates from the microspheres could be readily controlled with the introduction of USPIO nanoclusters. The MR relaxivity properties of the microspheres suggest the feasibility of in vivo imaging after administration and these microspheres exhibited potent therapeutic effects significantly inhibiting cell growth inducing apoptosis in hepatoma cells. PMID:24161384

  5. RECLAMATION OF ALKALINE ASH PILES

    EPA Science Inventory

    The objective of the study was to develop methods for reclaiming ash disposal piles for the ultimate use as agricultural or forest lands. The ashes studied were strongly alkaline and contained considerable amounts of salts and toxic boron. The ashes were produced from burning bit...

  6. In vivo Evaluation of Cenderitide-Eluting Stent (CES) II.

    PubMed

    Huang, Yingying; Ng, Xu Wen; Lim, Soon Ghim; Chen, Horng Haur; Burnett, John C; Boey, Yin Chiang Freddy; Venkatraman, Subbu S

    2016-02-01

    The use of drug-eluting coronary stents has led to significant reduction in in-stent restenosis (ISR), but led to delayed endothelialization, necessitating the prolonged use of expensive anti-thrombotic drugs with their side-effects. Cenderitide (CD-NP) is a novel anti-proliferative chimeric peptide of semi-endothelial origin. Our previous work in vitro has demonstrated; that the smooth muscle cells were inhibited significantly more than endothelial cells which is the desirable feature of an anti-restenosis drug. This work reports the effects of implantation of a centeritide-eluting stent (CES) on ISR and endothelialization in an in vivo model. CESs were produced by coating bare metallic stents with CD-NP entrapped in biodegradable poly(ε-caprolactone) using an ultrasonic spray coater. A total of 32 stents were successfully implanted into 16 pigs, and all animal survived for 28 days. The plasma levels of CD-NP were significantly higher in the CES group than in the control group (bare metal stents and polymer-coated stent) at post-stenting, indicating the successful release of CD-NP from the stent in vivo. Furthermore, SEM analysis results showed the greater endothelial coverage of the stent struts, as well as between the struts in CES group. Moreover, histological results showed mild inflammation, and low fibrin score at 28 days. However, plasma cGMP (second messenger, cyclic 3',5' guanosine monophosphate) does not show a significant difference, and the CES is also unable to show significant difference in terms on neointimal area and stenosis, in comparison to BMS at 28 days. PMID:26178873

  7. A monoclonal antibody against the surface of osteoblasts recognizes alkaline phosphatase isoenzymes in bone, liver, kidney, and intestine.

    PubMed

    Bruder, S P; Caplan, A I

    1990-01-01

    Monoclonal antibodies against the surface of embryonic osteogenic cells have been used to characterize the osteoblastic lineage. One antibody, SB-1, reacts in frozen sections with a family of cells in bone, liver, kidney, and intestine which are identically stained by the histochemical substrate for alkaline phosphatase. In this report, biochemical and immunochemical evidence is presented to indicate that SB-1 is directed against an epitope on alkaline phosphatase which is shared by isoenzymes in a variety of chick tissues. In a solid-phase assay system, high dilutions (1:10(5] of ascites fluid were found to give significant binding of SB-1 to alkaline phosphatase extracted from chick limb or intestine. Partial purification of intestinal alkaline phosphatase on a Sepharose CL-6B column results in the co-elution of alkaline phosphatase enzyme activity and antibody-binding material; this indicates that SB-1 recognizes intestinal alkaline phosphatase rather than an impurity in the crude preparation. Furthermore, Western immunoblots of chick calvarial bone extract electrophoresed on a 5-20% SDS-polyacrylamide gel show that SB-1 reacts with a single 155 kD band which also is stained by the alkaline phosphatase histochemical substrate. In a similar set of experiments, SB-1 reacts with an intestinal alkaline phosphatase isoenzyme whose molecular weight is approximately 185 kD. From these studies, we conclude that SB-1 is specifically reactive with alkaline phosphatase isoenzymes present in bone, liver, kidney, cartilage, and intestine. The reactive epitope is stable to SDS denaturation, not associated with the active site of the enzyme, and dependent on disulfide bonds which impart secondary structure to the protein. PMID:2357424

  8. Determinants of protein elution rates from preparative ion-exchange adsorbents.

    PubMed

    Angelo, James M; Lenhoff, Abraham M

    2016-04-01

    The rate processes involved in elution in preparative chromatography can affect both peak resolution and hence selectivity as well as practical factors such as facility fit. These processes depend on the physical structure of the adsorbent particles, the amount of bound solute, the solution conditions for operation or some combination of these factors. Ion-exchange adsorbents modified with covalently attached or grafted polymer layers have become widely used in preparative chromatography. Their often easily accessible microstructures offer substantial binding capacities for biomolecules, but elution has sometimes been observed to be undesirably slow. In order to determine which physicochemical phenomena control elution behavior, commercially available cellulosic, dextran-grafted and unmodified agarose materials were characterized here by their elution profiles at various conditions, including different degrees of loading. Elution data were analyzed under the assumption of purely diffusion-limited control, including the role of pore structure properties such as porosity and tortuosity. In general, effective elution rates decreased with the reduction of accessible pore volume, but differences among different proteins indicated the roles of additional factors. Additional measurements and analysis, including the use of confocal laser scanning microscopy to observe elution within single chromatographic particles, indicated the importance of protein association within the particle during elution. The use of protein stabilizing agents was explored in systems presenting atypical elution behavior, and l-arginine and disaccharide excipients were shown to alleviate the effects for one protein, lysozyme, in the presence of sodium chloride. Incorporation of these excipients into eluent buffer gave rise to faster elution and significantly lower pool volumes in elution from polymer-modified adsorbents. PMID:26948763

  9. Chapter A6. Section 6.6. Alkalinity and Acid Neutralizing Capacity

    USGS Publications Warehouse

    Rounds, Stewart A.; Wilde, Franceska D.

    2002-01-01

    Alkalinity (determined on a filtered sample) and Acid Neutralizing Capacity (ANC) (determined on a whole-water sample) are measures of the ability of a water sample to neutralize strong acid. Alkalinity and ANC provide information on the suitability of water for uses such as irrigation, determining the efficiency of wastewater processes, determining the presence of contamination by anthropogenic wastes, and maintaining ecosystem health. In addition, alkalinity is used to gain insights on the chemical evolution of an aqueous system. This section of the National Field Manual (NFM) describes the USGS field protocols for alkalinity/ANC determination using either the inflection-point or Gran function plot methods, including calculation of carbonate species, and provides guidance on equipment selection.

  10. Isolation of alkaline mutagens from complex mixtures

    SciTech Connect

    Ho, C.H.; Guerin, M.R.; Clark, B.R.; Rao, T.K.; Epler, J.L.

    1981-05-01

    A method for the preparative-scale enrichment of alkaline mutagens from complex natural and anthropogenic mixtures is described. Mutagenic alkaline fractions were isolated from cigarette smoke, crude petroleum, and petroleum substitutes derived from coal and shale.

  11. Nucleotide sequences encoding a thermostable alkaline protease

    DOEpatents

    Wilson, David B.; Lao, Guifang

    1998-01-01

    Nucleotide sequences, derived from a thermophilic actinomycete microorganism, which encode a thermostable alkaline protease are disclosed. Also disclosed are variants of the nucleotide sequences which encode a polypeptide having thermostable alkaline proteolytic activity. Recombinant thermostable alkaline protease or recombinant polypeptide may be obtained by culturing in a medium a host cell genetically engineered to contain and express a nucleotide sequence according to the present invention, and recovering the recombinant thermostable alkaline protease or recombinant polypeptide from the culture medium.

  12. Nucleotide sequences encoding a thermostable alkaline protease

    DOEpatents

    Wilson, D.B.; Lao, G.

    1998-01-06

    Nucleotide sequences, derived from a thermophilic actinomycete microorganism, which encode a thermostable alkaline protease are disclosed. Also disclosed are variants of the nucleotide sequences which encode a polypeptide having thermostable alkaline proteolytic activity. Recombinant thermostable alkaline protease or recombinant polypeptide may be obtained by culturing in a medium a host cell genetically engineered to contain and express a nucleotide sequence according to the present invention, and recovering the recombinant thermostable alkaline protease or recombinant polypeptide from the culture medium. 3 figs.

  13. Ceramic filters

    SciTech Connect

    Holmes, B.L.; Janney, M.A.

    1995-12-31

    Filters were formed from ceramic fibers, organic fibers, and a ceramic bond phase using a papermaking technique. The distribution of particulate ceramic bond phase was determined using a model silicon carbide system. As the ceramic fiber increased in length and diameter the distance between particles decreased. The calculated number of particles per area showed good agreement with the observed value. After firing, the papers were characterized using a biaxial load test. The strength of papers was proportional to the amount of bond phase included in the paper. All samples exhibited strain-tolerant behavior.

  14. CONCENTRATION AND PROCESSING OF WATERBORNE VIRUSES BY POSITIVE CHARGE 1MDS CARTRIDGE FILTERS AND ORGANIC FLOCCULATION

    EPA Science Inventory

    This chapter describes the most widely used virus adsorption-elution (VIRADEL) method for recovering human enteric viruses from water matrices (Fout et al., 1996). The method takes advantage of postively charged cartridge filters to concentrate viruses from water. The major adv...

  15. Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost.

    PubMed

    Arat Ozkan, Alev; Sinan, Umit Yasar; Gurmen, Aziz T

    2016-01-01

    Stent fracture is a rare complication of drug-eluting stent implantation with a reported rate of 0.84%-3.2% in various clinical studies with first-generation drug-eluting stents and 29% in autopsy studies. Sirolimus-eluting stents with their closed cell design were reported to be more prone to fracture compared to paclitaxel-eluting stents. Other risk factors for stent fracture are multiple stenting, longer stent length, chronic renal failure, right coronary artery intervention, and a higher maximal inflation pressure. The role of angiography in diagnosing stent fracture is limited, a fact also questioning the reliability of angiographic data. Image enhancement techniques like StentBoost are widely available in new-generation angiography systems and are used to assess stent expansion, overlap size, or to localize the postdilation balloon. Here, we report a case of zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost. PMID:27489714

  16. Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost

    PubMed Central

    Arat Ozkan, Alev; Sinan, Umit Yasar; Gurmen, Aziz T

    2016-01-01

    Stent fracture is a rare complication of drug-eluting stent implantation with a reported rate of 0.84%–3.2% in various clinical studies with first-generation drug-eluting stents and 29% in autopsy studies. Sirolimus-eluting stents with their closed cell design were reported to be more prone to fracture compared to paclitaxel-eluting stents. Other risk factors for stent fracture are multiple stenting, longer stent length, chronic renal failure, right coronary artery intervention, and a higher maximal inflation pressure. The role of angiography in diagnosing stent fracture is limited, a fact also questioning the reliability of angiographic data. Image enhancement techniques like StentBoost are widely available in new-generation angiography systems and are used to assess stent expansion, overlap size, or to localize the postdilation balloon. Here, we report a case of zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost. PMID:27489714

  17. Selective elution of HLA antigens and beta 2-microglobulin from human platelets by chloroquine diphosphate

    SciTech Connect

    Kao, K.J.

    1988-01-01

    To determine whether chloroquine can specifically elute HLA antigens and beta 2-microglobulin (beta 2-M) from the platelet surface, quantitative immunofluorescence flow cytometry and monoclonal antibodies were used to show that HLA antigens and beta 2-M were proportionally eluted from the platelet surface without affecting the membrane glycoproteins IIb and IIIa. Second, an autoradiogram of electrophoresed I-125-labeled platelets showed that only beta 2-M but not other I-125-labeled membrane proteins could be eluted. Although HLA antigens were poorly labeled by I-125 and could not be detected on the autoradiogram, the eluted HLA antigens could be detected by anti-HLA monoclonal antibody and immunoblotting techniques. No loss of plasma membrane integrity was observed by transmission electron microscopy after chloroquine treatment of platelets. The results indicate that chloroquine selectively elutes HLA antigens and their noncovalently associated beta 2-M without affecting other integral platelet membrane proteins.

  18. From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    PubMed

    Tenekecioglu, Erhan; Bourantas, Christos; Abdelghani, Mohammad; Zeng, Yaping; Silva, Rafael Cavalcante; Tateishi, Hiroki; Sotomi, Yohei; Onuma, Yoshinobu; Yılmaz, Mustafa; Serruys, Patrick W

    2016-03-01

    Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the anti-proliferative drug. Despite significant decreases in in-stent restenosis rates with drug eluting stents, limitations still remain before we are able to develop fully bioresorbable scaffolds. Enhanced mechanical flexibility that provides superior conformability to the vessel wall, resumption of the vasoreactivity in the follow-up period and improving visualization on non-invasive imaging modalities are some of the supremacies of the fully bioresorbable scaffolds. In this review, we aim to give a general view on the latest developments in metallic drug eluting stents and fully bioresorbable scaffolds. PMID:26782080

  19. Development of alkaline fuel cells.

    SciTech Connect

    Hibbs, Michael R.; Jenkins, Janelle E.; Alam, Todd Michael; Janarthanan, Rajeswari; Horan, James L.; Caire, Benjamin R.; Ziegler, Zachary C.; Herring, Andrew M.; Yang, Yuan; Zuo, Xiaobing; Robson, Michael H.; Artyushkova, Kateryna; Patterson, Wendy; Atanassov, Plamen Borissov

    2013-09-01

    This project focuses on the development and demonstration of anion exchange membrane (AEM) fuel cells for portable power applications. Novel polymeric anion exchange membranes and ionomers with high chemical stabilities were prepared characterized by researchers at Sandia National Laboratories. Durable, non-precious metal catalysts were prepared by Dr. Plamen Atanassov's research group at the University of New Mexico by utilizing an aerosol-based process to prepare templated nano-structures. Dr. Andy Herring's group at the Colorado School of Mines combined all of these materials to fabricate and test membrane electrode assemblies for single cell testing in a methanol-fueled alkaline system. The highest power density achieved in this study was 54 mW/cm2 which was 90% of the project target and the highest reported power density for a direct methanol alkaline fuel cell.

  20. Spatiotemporal dynamics of doxorubicin elution from embolic beads within a microfluidic network.

    PubMed

    Carugo, Dario; Capretto, Lorenzo; Roy, Bibhas; Carboni, Michele; Caine, Marcus; Lewis, Andrew L; Hill, Martyn; Chakraborty, Suman; Zhang, Xunli

    2015-09-28

    Anticancer treatment using embolic drug-eluting beads (DEBs) has shown multifarious advantages compared to systemic chemotherapy. However, there is a growing need for a better understanding of the physical parameters governing drug-elution from embolic devices under physiologically relevant fluidic conditions. In the present study, we investigated the spatiotemporal dynamics of doxorubicin hydrochloride elution from drug-loaded hydrogel embolic beads within a microfluidic device consisting of a network of interconnected microchannels which replicates the architectural properties of microvascular systems. Drug-elution has been investigated experimentally at a single-bead level, using in-house developed microscopy- and spectrofluorimetry-based methods. Results demonstrated that the kinetics of drug-elution and the amount of eluted drug strongly depended on the location of the embolic event within the embolised channel (e.g. fractional amount of eluted drug after 3h was equal to ~0.2 and ~0.6 for completely-confined and partially-confined bead, respectively). Drug-elution from partially-confined bead showed a counterintuitive dependence on the local Reynolds number (and thus on the mean fluid velocity), as a result of dynamic changes in bead compressibility causing the displacement of the bead from the primary embolic site. Conversely, the kinetics of drug-elution from fully-confined bead was less affected by the local Reynolds number and bead displayed faster elution from the surface area exposed to the systemic flow, which was associated with the formation of fluid eddies nearby the bead post embolisation. PMID:26160306

  1. Prognostic Significance of Polymer Coatings in Zotarolimus-Eluting Stents.

    PubMed

    Iqbal, M Bilal; Nadra, Imad J; Din, Jehangir N; Hendry, Cara; Ding, Lillian; Fung, Anthony; Aymong, Eve; Chan, Albert W; Hodge, Steven; Robinson, Simon D; Della Siega, Anthony

    2016-03-01

    Polymer coatings on drug-eluting stents (DES) serve as a vehicle for delivery of antirestenotic drugs. Whether they influence outcomes for contemporary DES is unknown. The evolution of polymer coatings for zotarolimus-eluting stents (ZES) provides a natural experiment that facilitates such analysis. The Resolute ZES (R-ZES) uses the same antirestenotic drug as the Endeavor ZES (E-ZES) but has a more biocompatible polymer with enhanced drug release kinetics. However, there are limited data on the real-world comparative efficacy of R-ZES and the preceding E-ZES. Thus, we analyzed 17,643 patients who received either E-ZES or R-ZES from 2008 to 2014 from the British Columbia Cardiac Registry. A total of 9,869 patients (56%) received E-ZES and 7,774 patients (44%) received R-ZES. Compared with E-ZES, R-ZES was associated with lower 2-year mortality (4.1% vs 6.4%, p <0.001) and 2-year target vessel revascularization (TVR; 6.8% vs 10.7%, p <0.001). R-ZES use was an independent predictor of lower mortality rate and TVR. This was confirmed in propensity-matched analyses for 2-year mortality (hazard ratio [HR] 0.59, 95% CI 0.49 to 0.71, p <0.001) and 2-year TVR (HR 0.86, 95% CI 0.75 to 0.98, p = 0.032). Instrumental variable analyses demonstrated R-ZES to be associated with lower 2-year mortality (Δ = -2.2%, 95% CI -4.3% to -0.2%, p = 0.032) and 2-year TVR (Δ = -3.3% to 95% CI -6.1% to -0.7%, p = 0.015). Acknowledging the limitations of observational analyses, this study has shown that R-ZES was associated with lower long-term TVR and mortality. These data are reassuring for the newer R-ZES and demonstrate how polymer coatings may influence the clinical performance of DES with wider implications for future DES development and design. PMID:26796194

  2. Poliovirus concentration from tap water with electropositive adsorbent filters.

    PubMed

    Sobsey, M D; Glass, J S

    1980-08-01

    Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels. PMID:6258472

  3. Drug-Eluting Stent: A Review and Update

    PubMed Central

    Htay, Thein; Liu, Ming W

    2005-01-01

    The development of stent has been a major advance in the treatment of obstructive coronary artery disease since the introduction of balloon angioplasty. However, neointimal hyperplasia occurring within the stent leading to in-stent restenosis is a main obstacle in the long-term success of percutaneous coronary intervention (PCI). The recent introduction of drug-eluting stents (DES) contributes a major breakthrough to interventional cardiology. Many large randomized clinical trials using DES have shown a remarkable reduction in angiographic restenosis and target vessel revascularization when compared with bare metal stents. The results of these trials also appear to be supported by evidence from everyday practice and noncontrolled clinical trials. However, the expanded applications of DES, especially in treating complex lesions such as left main trunk, bifurcation, saphenous vein graft lesions, or in-stent restenosis, are still under evaluation with ongoing studies. With the availability of different types of DES in the market, the issue of cost should not be a deterrent and DES will eventually be an economically viable option for all patients. The adoption of DES in all percutaneous coronary intervention may become a reality in the near future. In this review article, we summarize the recent development and progress of DES as well as compare and update the results of clinical trials. PMID:17315599

  4. Antiplatelet therapy after drug-eluting stent implantation.

    PubMed

    Warren, Josephine; Baber, Usman; Mehran, Roxana

    2015-02-01

    Dual antiplatelet therapy (DAPT), which is the combination of aspirin and a platelet P2Y12 inhibitor, is the cornerstone of secondary prevention in ischemic heart disease requiring intracoronary stenting. Although the efficacy of DAPT in the reduction of ischemic events has been well validated, the optimal duration, and indeed combination, of therapy is yet to be established. This area continues to attract debate with new developments in stent design and antiplatelet agents, as well as evolving clinical skill levels. Presently, clinical guidelines advocate the use of DAPT for 6-12 months following drug-eluting stent (DES) implantation, but this can vary according to clinical indication, bleeding risk, and country of practice. Concerns have arisen that unnecessary prolongation of DAPT may be associated with increased bleeding events, as well as cost. Whether these guidelines effectively cater to current stenting techniques, devices, and antiplatelet agents remains to be determined. This review analyzes contemporary issues surrounding DAPT following DES implantation, as researchers continue to seek to strike the optimal balance between bleeding and thrombotic risk. Although reduced DAPT durations continue to show promising results in preventing ischemic events while also mitigating bleeding risk, ultimately the consideration of clinical presentation as well as medical and social history is paramount to guiding the optimal duration and cessation of DAPT. PMID:25467922

  5. The ultimate band compression factor in gradient elution chromatography

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2008-01-01

    The equations predicting the ultimate time band compression factor, G = (t{sub R}-t{sub F})/t{sub p} in linear gradient elution chromatography, for an infinitely narrow injection (injection time t{sub p} {yields} 0) were derived for an ideal-model column (dispersionless chromatography, H = 0) assuming the Linear Solvent Strength Model for the retention behavior of the analyte. Numerical solutions can readily be obtained when the LSSM model does not apply. The results can be generalized to any retained organic modifier (k'{sub A}) in the mobile phase. The stronger the retention of the organic modifier, the more effective the band compression. Dispersion in real chromatographic column (H {ne} 0) affects the limits that can be reached in linear gradients but poorly in step gradients. Examples based on a conventional HETP of about 12 {micro}m using a 5 {micro}m particle packed column reveal that the best time compression factor that could be expected is twice the one predicted with an ideal column.

  6. Silver ions eluted from partially protected silver nanoparticles.

    PubMed

    Heidari Zare, Hamideh; Düttmann, Oliver; Vass, Attila; Franz, Gerhard; Jocham, Dieter

    2016-01-01

    The most prominent character of a new type of antibacterial urological catheters is the zebra-stripe pattern of a silver film, which is plated electroless on their interior wall and capped by a very thin semipermeable layer of parylene. This design effectively controls the release rate of Ag(+) ions in artificial urine, which has been measured as function of time with optical emission spectroscopy. By evaluating the minimum inhibitory concentration against certain strains of bacteria with solutions of AgNO3 of known concentration with the method of optical density and applying this analysis to the silver-eluting catheters, it was shown that this moderation prolongs the period of their application significantly. But to act as antibacterial agent in chlorine-containing solutions, as in urine, the presence of urea is required to avoid precipitation of AgCl and to meet or even exceed the minimum inhibitory concentration of Ag(+). The quality of the silver depot layer was further determined by the deposition rate and its morphology, which revealed that the film consisted of grains with a mean size of 150 nm. PMID:27400747

  7. Bone healing by sterilizable calcium phosphate tetrapods eluting osteogenic molecules.

    PubMed

    Maeda, Yujiro; Hojo, Hironori; Shimohata, Nobuyuki; Choi, Sungjin; Yamamoto, Kenichi; Takato, Tsuyoshi; Chung, Ung-il; Ohba, Shinsuke

    2013-07-01

    Although bone grafts and prosthetic implants have shown some clinical success in the treatment of bone defects, the graft availability, biocompatibility, function, and longevity still remain to be improved. One possible solution to these problems is to develop bone implants acting on host cells to induce rapid bone regeneration. Here, we demonstrate bone healing by means of a sterilizable and osteogenic molecule-eluting implant system in which two small molecules, a smoothened agonist (SAG) and a helioxanthin derivative (TH), are loaded onto tetrapod-shaped calcium phosphate granules (Tetrabone). We succeeded in directing progenitor cells toward mature osteoblasts with the combined application of the two small molecules acting on different stages of osteogenesis. Tetrabone released SAG and TH for prolonged periods when loaded with these molecules. EOG sterilization did not affect the osteogenic activity of the SAG- and TH-loaded Tetrabones. The combinatorial use of SAG- and TH-loaded Tetrabones achieved bone healing without cell transplantation in a rat femur bone defect model within two weeks. This system will allow us to vary the combination rate of implants loaded with different osteogenic factors depending on the types and sizes of defects, potentially allowing full temporal and spatial control of the bone regeneration. PMID:23623228

  8. EVALUATION OF POTENTIAL ELUANTS FOR NON-ACID ELUTION OF CESIUM FROM SPHERICAL RESORCINOL-FORMALDEHYDE RESIN

    SciTech Connect

    Adu-Wusu, K.; Nash, C.; Pennebaker, F.

    2011-10-23

    Ion Exchange column loading and elution of cesium from spherical resorcinol-formaldehyde resin have been conducted for two potential non-acid eluants -(NH{sub 4}){sub 2}CO{sub 3} and CH{sub 3}COONH{sub 4}. The results revealed encouraging cesium elution performance. 100% elution was achieved in at most 22 hours ({approx}28 bed volumes) of elution. Elution performance was fairly high at 6 hours ({approx}8 bed volumes) of elution for some of the eluants and also practically comparable to the benchmark acid eluant (HNO{sub 3}). Hence, it is quite possible 100% percent elution will be closer to the 6th hour than the 22nd hour. Elution is generally enhanced by increasing the concentration and pH of the eluants, and combining the eluants.

  9. Drug eluting biliary stents to decrease stent failure rates: A review of the literature

    PubMed Central

    Shatzel, Joseph; Kim, Jisoo; Sampath, Kartik; Syed, Sharjeel; Saad, Jennifer; Hussain, Zilla H; Mody, Kabir; Pipas, J Marc; Gordon, Stuart; Gardner, Timothy; Rothstein, Richard I

    2016-01-01

    Biliary stenting is clinically effective in relieving both malignant and non-malignant obstructions. However, there are high failure rates associated with tumor ingrowth and epithelial overgrowth as well as internally from biofilm development and subsequent clogging. Within the last decade, the use of prophylactic drug eluting stents as a means to reduce stent failure has been investigated. In this review we provide an overview of the current research on drug eluting biliary stents. While there is limited human trial data regarding the clinical benefit of drug eluting biliary stents in preventing stent obstruction, recent research suggests promise regarding their safety and potential efficacy. PMID:26839648

  10. Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

    PubMed Central

    Otsuki, Shuji; Sabaté, Manel

    2014-01-01

    Primary percutaneous coronary intervention is the preferred reperfusion strategy for patients presenting with ST-segment elevation myocardial infarction (STEMI). First generation drug-eluting stents (DES), (sirolimus drug-eluting stents and paclitaxel drug-eluting stents), reduce the risk of restenosis and target vessel revascularization compared to bare metal stents. However, stent thrombosis emerged as a major safety concern with first generation DES. In response to these safety issues, second generation DES were developed with different drugs, improved stent platforms and more biocompatible durable or bioabsorbable polymeric coating. This article presents an overview of safety and efficacy of the first and second generation DES in STEMI. PMID:25276295

  11. Drug eluting biliary stents to decrease stent failure rates: A review of the literature.

    PubMed

    Shatzel, Joseph; Kim, Jisoo; Sampath, Kartik; Syed, Sharjeel; Saad, Jennifer; Hussain, Zilla H; Mody, Kabir; Pipas, J Marc; Gordon, Stuart; Gardner, Timothy; Rothstein, Richard I

    2016-01-25

    Biliary stenting is clinically effective in relieving both malignant and non-malignant obstructions. However, there are high failure rates associated with tumor ingrowth and epithelial overgrowth as well as internally from biofilm development and subsequent clogging. Within the last decade, the use of prophylactic drug eluting stents as a means to reduce stent failure has been investigated. In this review we provide an overview of the current research on drug eluting biliary stents. While there is limited human trial data regarding the clinical benefit of drug eluting biliary stents in preventing stent obstruction, recent research suggests promise regarding their safety and potential efficacy. PMID:26839648

  12. Anode conductor for alkaline cells

    SciTech Connect

    Schrenk, D.J.; Murphy, P.E.

    1988-12-13

    This patent describes an electrochemical cell comprised of an anode comprised of zinc; a cathode; and alkaline electrolyte; and a current collector comprised of a silicon bronze alloy that is comprised of 85-98% by weight copper and 1-5% by weight silicon with the remainder being comprised of at least one of manganese, iron, zinc, aluminum, tin, lead, or mixtures thereof; and a strip of metal tab stock welded to the current collector, the tab stock being a metal other than silicon bronze alloy.

  13. Alkaline fuel cell performance investigation

    NASA Technical Reports Server (NTRS)

    Martin, R. E.; Manzo, M. A.

    1988-01-01

    An exploratory experimental fuel cell test program was conducted to investigate the performance characteristics of alkaline laboratory research electrodes. The objective of this work was to establish the effect of temperature, pressure, and concentration upon performance and evaluate candidate cathode configurations having the potential for improved performance. The performance characterization tests provided data to empirically establish the effect of temperature, pressure, and concentration upon performance for cell temperatures up to 300 F and reactant pressures up to 200 psia. Evaluation of five gold alloy cathode catalysts revealed that three doped gold alloys had more than two times the surface areas of reference cathodes and therefore offered the best potential for improved performance.

  14. Alkaline fuel cell performance investigation

    NASA Technical Reports Server (NTRS)

    Martin, R. E.; Manzo, M. A.

    1988-01-01

    An exploratory experimental fuel cell test program was conducted to investigate the performance characteristics of alkaline laboratory research electrodes. The objective of this work was to establish the effect of temperature, pressure, and concentration upon performance and evaluate candidate cathode configurations having the potential for improved performance. The performance characterization tests provided data to empirically establish the effect of temperature, pressure, and concentration upon performance for cell temperatures up to 300 F and reactant pressures up to 200 psia. Evaluation of five gold alloy cathode catalysts revealed that three doped gold alloys had more that two times the surface areas of reference cathodes and therefore offered the best potential for improved performance.

  15. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries

    PubMed Central

    Galon, Micheli Z.; Gutierrez, Paulo S.; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A.

    2015-01-01

    Background Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). Methods In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. Results According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. Conclusions The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies. PMID:25984451

  16. Silver Dissolution and Release from Ceramic Water Filters.

    PubMed

    Mittelman, Anjuliee M; Lantagne, Daniele S; Rayner, Justine; Pennell, Kurt D

    2015-07-21

    Application of silver nanoparticles (nAg) or silver nitrate (AgNO3) has been shown to improve the microbiological efficacy of ceramic water filters used for household water treatment. Silver release, however, can lead to undesirable health effects and reduced filter effectiveness over time. The objectives of this study were to evaluate the contribution of nanoparticle detachment, dissolution, and cation exchange to silver elution, and to estimate silver retention under different influent water chemistries. Dissolved silver (Ag(+)) and nAg release from filter disks painted with 0.03 mg/g casein-coated nAg or AgNO3 were measured as a function of pH (5-9), ionic strength (1-50 mM), and cation species (Na(+), Ca(2+), Mg(2+)). Silver elution was controlled by dissolution as Ag(+) and subsequent cation exchange reactions regardless of the applied silver form. Effluent silver levels fell below the drinking water standard (0.1 mg/L) after flushing with 30-42 pore volumes of pH 7, 10 mM NaNO3 at pH 7. When the influent water was at pH 5, contained divalent cations or 50 mM NaNO3, silver concentrations were 5-10 times above the standard. Our findings support regular filter replacement and indicate that saline, hard, or acidic waters should be avoided to minimize effluent silver concentrations and preserve silver treatment integrity. PMID:26068303

  17. Grace DAKASEP alkaline battery separator

    NASA Technical Reports Server (NTRS)

    Giovannoni, R. T.; Lundquist, J. T.; Choi, W. M.

    1987-01-01

    The Grace DAKASEP separator was originally developed as a wicking layer for nickel-zinc alkaline batteries. The DAKASEP is a filled non-woven separator which is flexible and heat sealable. Through modification of formulation and processing variables, products with a variety of properties can be produced. Variations of DAKASEP were tested in Ni-H2, Ni-Zn, Ni-Cd, and primary alkaline batteries with good results. The properties of DAKASEP which are optimized for Hg-Zn primary batteries are shown in tabular form. This separator has high tensile strength, 12 micron average pore size, relatively low porosity at 46-48 percent, and consequently moderately high resistivity. Versions were produced with greater than 70 percent porosity and resistivities in 33 wt percent KOH as low as 3 ohm cm. Performance data for Hg-Zn E-1 size cells containing DAKASEP with the properties shown in tabular form, are more reproducible than data obtained with a competitive polypropylene non-woven separator. In addition, utilization of active material is in general considerably improved.

  18. A completely fractured zotarolimus-eluting stent in an aortocoronary saphenous vein bypass graft.

    PubMed

    Venero, Carmelo V; Aligeti, Venkata R; Wortham, Dale C

    2013-01-01

    Drug-eluting stents (DES) have significantly improved the rate of target vessel revascularization in comparison with bare metal stents. DES fracture was not reported in multicenter randomized clinical trials, but several case reports of DES fracture have been published, mostly with sirolimus-eluting stents. DES fracture is associated with stent restenosis and thrombosis. We report a zotarolimus-eluting stent fracture in an aortocoronary saphenous vein graft (SVG) bypass. The patient presented with chest pain and a non-ST-elevation myocardial infarction. He underwent cardiac catheterization that showed a complete fracture of a zotarolimus-eluting stent in the ostium of a sequential SVG to the diagonal and obtuse coronary arteries. His management included coronary angioplasty and retrieval of the proximal fractured segment. We discuss the potential causes for this stent fracture and suggest caution when using a DES in an ostial location of a SVG bypass, especially in a highly mobile vessel. PMID:22553171

  19. Inflammation and impaired wound healing after zotarolimus-eluting stent implantation.

    PubMed

    Yoneda, Shuichi; Abe, Shichiro; Taguchi, Isao; Masawa, Nobuhide; Inoue, Katsumi; Inoue, Teruo

    2012-01-01

    An 86-year-old man died suddenly 5 months after implantation of a zotarolimus-eluting stent. Two zotarolimus-eluting stents were placed to treat a highly calcified diffuse lesion in the proximal-to-mid right coronary artery. The lesion was fully covered by the two stents, and intravascular ultrasound showed complete stent apposition. However, an X-ray at autopsy showed that the proximal stent was fractured. Although we thought that thrombotic occlusion at the fracture site might have caused his sudden death, no thrombus was present. In addition, in the other sites where the stents were optimally dilated, there was stent malapposition and peri-strut inflammation including macrophage infiltration, giant cells, polymer phagocytosis, and neovascularization in the neointima. Even with a second-generation drug-eluting stent, such as the zotarolimus-eluting stent, wound healing may be impaired at the stent-injured vessel site. PMID:22356902

  20. Oral Factors Affecting Titanium Elution and Corrosion: An In Vitro Study Using Simulated Body Fluid

    PubMed Central

    Suito, Hideki; Iwawaki, Yuki; Goto, Takaharu; Tomotake, Yoritoki; Ichikawa, Tetsuo

    2013-01-01

    Objectives Ti, which is biocompatible and resistant to corrosion, is widely used for dental implants, particularly in patients allergic to other materials. However, numerous studies have reported on Ti allergy and the in vitro corrosion of Ti. This study investigated the conditions that promote the elution of Ti ions from Ti implants. Methods Specimens of commercially pure Ti, pure nickel, a magnetic alloy, and a gold alloy were tested. Each specimen was immersed in a simulated body fluid (SBF) whose pH value was controlled (2.0, 3.0, 5.0, 7.4, and 9.0) using either hydrochloric or lactic acid. The parameters investigated were the following: duration of immersion, pH of the SBF, contact with a dissimilar metal, and mechanical stimulus. The amounts of Ti ions eluted were measured using a polarized Zeeman atomic absorption spectrophotometer. Results Eluted Ti ions were detected after 24 h (pH of 2.0 and 3.0) and after 48 h (pH of 9.0). However, even after 4 weeks, eluted Ti ions were not detected in SBF solutions with pH values of 5.0 and 7.4. Ti elution was affected by immersion time, pH, acid type, mechanical stimulus, and contact with a dissimilar metal. Elution of Ti ions in a Candida albicans culture medium was observed after 72 h. Significance Elution of Ti ions in the SBF was influenced by its pH and by crevice corrosion. The results of this study elucidate the conditions that lead to the elution of Ti ions in humans, which results in implant corrosion and Ti allergy. PMID:23762461

  1. Alkaline and alkaline earth metal phosphate halides and phosphors

    SciTech Connect

    Lyons, Robert Joseph; Setlur, Anant Achyut; Cleaver, Robert John

    2012-11-13

    Compounds, phosphor materials and apparatus related to nacaphite family of materials are presented. Potassium and rubidium based nacaphite family compounds and phosphors designed by doping divalent rare earth elements in the sites of alkaline earth metals in the nacaphite material families are descried. An apparatus comprising the phosphors based on the nacaphite family materials are presented herein. The compounds presented is of formula A.sub.2B.sub.1-yR.sub.yPO.sub.4X where the elements A, B, R, X and suffix y are defined such that A is potassium, rubidium, or a combination of potassium and rubidium and B is calcium, strontium, barium, or a combination of any of calcium, strontium and barium. X is fluorine, chlorine, or a combination of fluorine and chlorine, R is europium, samarium, ytterbium, or a combination of any of europium, samarium, and ytterbium, and y ranges from 0 to about 0.1.

  2. Effects of ageing on elution behaviour of nitrogenous compounds in disposed wastes from landfill sites.

    PubMed

    Nishio, Takayuki

    2014-01-01

    Comparative studies of elution and cation exchange capacity (CEC) tests were applied to aged and fresh municipal and industrial solid wastes to examine the effects of ageing on the long-term elution behaviour of nitrogen on leachate in municipal and industrial solid waste landfill sites. Nitrogen in the leachate gradually eluted as organic nitrogen, but not upon transformation of organic nitrogen to elutable inorganic nitrogen compounds in the solid waste. Ammonium in the solid waste, retained similar to its interaction with clay minerals in soil, elutes when exposed to leachate by being replaced with highly concentrated cations or loses its positive charge in high pH in the leachate, which percolates down from the upper layer of the disposed waste. The quantity of ammonium adsorbed into the aged wastes through CEC measurement process by replacement with ammonium acetate was higher than that onto the fresh wastes. That difference in quantities can serve as an index of the ability of the solid waste to withhold ammonium in the leachate that percolates down the landfill layer. Those results demonstrate that ammonification of organic nitrogen in the waste is not the crucial step of the elution of nitrogenous compounds into leachate. PMID:25145199

  3. Nonspecific native elution of proteins and mumps virus in immunoaffinity chromatography.

    PubMed

    Brgles, Marija; Sviben, Dora; Forčić, Dubravko; Halassy, Beata

    2016-05-20

    Immunoaffinity chromatography, based on the antigen-antibody recognition, enables specific purification of any antigen (protein, virus) by its antibody. The problem with immunoaffinity chromatography is the harsh elution conditions required for disrupting strong antigen-antibody interactions, such as low pH buffers, which are often deleterious for the immobilized protein and the protein to be isolated since they can also disrupt the intramolecular forces. Therefore, immunoaffinity chromatography can only be partially used for protein and virus purification. Here we report on a nonspecific elution in immunoaffinity chromatography using native conditions by elution with amino acid solution at physiological pH for which we suppose possible competing mechanism of action. Elution potential of various amino acid solutions was tested using immunoaffinity columns specific for ovalbumin and mumps virus, and protein G affinity column. Results have shown that the most successful elution solutions were those containing imidazole and arginine of high molarity. Imidazole represents aromatic residues readily found at the antigen-antibody interaction surface and arginine is most frequently found on protein surface in general. Therefore, results on their eluting power in immunoaffinity chromatography, which increases with increasing molarity, are in line with the competing mechanism of action. Virus immunoaffinity chromatography resulted in removal on nonviable virus particles, which is important for research and biotechnology purposes. In addition, amino acids are proven stabilizers for proteins and viruses making approach presented in this work a very convenient purification method. PMID:27090389

  4. Multiple enzyme purifications from muscle extracts by using affinity-elution-chromatographic procedures.

    PubMed Central

    Scopes, R K

    1977-01-01

    1. Starting with (NH4)2SO4 fractions of muscle extracts, procedures for purifying four to six separate enzymes from each fraction by using affinity-elution-chromatographic techniques are described. 2. Schemes for purifying 12 separate enzymes from rabbit muscle, and eight from chicken muscle extracts, are included. In nearly all cases the overall procedure involves three steps: the initial (NH4)2SO4 fractionation, the ion-exchange chromatography with affinity elution of the enzyme, and gel filtration. The specific activities of the enzymes so purified are comparable with the highest values in the literature. 3. The five schemes described include illustrations of affinity elution of the separate enzymes at different pH values, at different ionic strengths and in combination with conventional gradient elution. They also include stepwise adsorption on columns at different pH values. 4. Separation of two electrophoretically differing forms of phosphoglycerate kinase was achieved by gradient affinity elution from CM-cellulose. The lower-pI form was eluted by a lower concentration of substrate than the higher-pI form. PMID:849261

  5. Size and composition of synthetic calcium sulfate beads influence dissolution and elution rates in vitro.

    PubMed

    Roberts, Randy; McConoughey, Stephen J; Calhoun, Jason H

    2014-05-01

    Treatments of osteomyelitis lag behind bacterial resistance to antibiotics. We tested different-sized calcium sulfate beads and their ability to elute multiple antibiotics in vitro as a possible method to improve the therapeutic delivery in patients. Two sizes of calcium sulfate beads (4.8 and 3.0 mm diameter) that contained vancomycin, tobramycin, or both were dissolved in phosphate-buffered saline, and the rate of dissolution by weight and antibiotic elution by the disc diffusion assay and high-pressure liquid chromatography were measured. The 4.8 mm beads showed significantly higher dissolution rates relative to the 3.0 mm beads (2.3 mg/day vs. 1.3 mg/day). While the vancomycin-loaded 4.8 mm beads eluted for a longer time relative to the 3.0 mm beads (20 days vs. 10 days), the smaller beads had threefold higher elution for the first 2 days, before dropping to near zero elution by day 4. The presence of tobramycin extended the elution of the vancomycin to day 40, which closely matches the recommended 6 weeks to treat orthopedic staphylococcus infections. These data suggest that size and content of the bead are variables that could affect their clinical success, and both could be exploited to tailor treatments of specific infections and injuries. PMID:24155136

  6. The control of mercury vapor using biotrickling filters.

    PubMed

    Philip, Ligy; Deshusses, Marc A

    2008-01-01

    The feasibility of using biotrickling filters for the removal of mercury vapor from simulated flue gases was evaluated. The experiments were carried out in laboratory-scale biotrickling filters with various mixed cultures naturally attached on a polyurethane foam packing. Sulfur oxidizing bacteria, toluene degraders and denitrifiers were used and compared for their ability to remove Hg 0 vapor. In particular, the biotrickling filters with sulfur oxidizing bacteria were able to remove 100% of mercury vapor, with an inlet concentration of 300-650 microg m(-3), at a gas contact time as low as six seconds. 87-92% of the removed mercury was fixed in or onto the microbial cells while the remaining left the system with the trickling liquid. The removal of mercury vapors in a biotrickling filter with dead cells was almost equivalent to this in biotrickling filters with live cells, indicating that significant abiotic removal mechanisms existed. Sulfur oxidizing bacteria biotrickling filters were the most effective in controlling mercury vapors, suggesting that sulfur played a key role. Identification of the location of metal deposition and of the form of metal was conducted using TEM, energy dispersive X-ray analysis (EDAX) and mercury elution analyses. The results suggested that mercury removal was through a series of complex mechanisms, probably both biotic and abiotic, including sorption in and onto cellular material and possible biotransformations. Overall, the study demonstrates that biotrickling filters appear to be a promising alternative for mercury vapor removal from flue gases. PMID:17692357

  7. Simulation of elution profiles in liquid chromatography-I: Gradient elution conditions, and with mismatched injection and mobile phase solvents.

    PubMed

    Jeong, Lena N; Sajulga, Ray; Forte, Steven G; Stoll, Dwight R; Rutan, Sarah C

    2016-07-29

    High-performance liquid chromatography (HPLC) simulators are effective method development tools. The goal of the present work was to design and implement a simple algorithm for simulation of liquid chromatographic separations that allows for characterization of the effect of injection solvent mismatch and injection solvent volume overload. The simulations yield full analyte profiles during solute migration and at elution, which enable a thorough physical understanding of the effects of method variables on chromatographic performance. The Craig counter-current distribution model (the plate model) is used as the basis for simulation, where a local retention factor is assigned for each spatial and temporal element within the simulation. The algorithm, which is an adaptation of an approach originally described by Czok and Guiochon (Ref. [10]), is sufficiently flexible to allow the use of either linear (e.g., Linear Solvent Strength Theory) or non-linear models of solute retention (e.g., Neue-Kuss (Ref. [36])). In this study, both types of models were used, one for simulating separations of a homologous series of alkylbenzenes, and the other for separations of selected amphetamines. The simulation program was validated first by comparison of simulated retention times and peak widths for five amphetamines to predictions obtained using linear solvent strength (LSS) theory, and to results from experimental separations of these compounds. The simulated retention times for the amphetamines agreed within 0.02% and 2.5% compared to theory and experiment, respectively. Secondly, the program was evaluated for simulating the case where there is a compositional mismatch between the mobile phase at the column inlet and the injection solvent (i.e., the sample matrix). This work involved alkylbenzenes, and retention time and peak width predictions from simulations were within 1.5 and 6.0% of experimental values, respectively, even without correction for extra-column dispersion. The

  8. HEPA filter dissolution process

    SciTech Connect

    Brewer, K.N.; Murphy, J.A.

    1992-12-31

    This invention is comprised of a process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

  9. Recirculating electric air filter

    DOEpatents

    Bergman, Werner

    1986-01-01

    An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  10. Hepa filter dissolution process

    DOEpatents

    Brewer, Ken N.; Murphy, James A.

    1994-01-01

    A process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

  11. HEPA filter dissolution process

    DOEpatents

    Brewer, K.N.; Murphy, J.A.

    1994-02-22

    A process is described for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal. 4 figures.

  12. Recirculating electric air filter

    DOEpatents

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  13. Process for extracting technetium from alkaline solutions

    SciTech Connect

    Moyer, B.A.; Sachleben, R.A.; Bonnesen, P.V.

    1994-12-31

    This invention relates generally to a process for extracting technetium from nuclear wastes and more particularly to a process for extracting technetium from alkaline waste solutions containing technetium and high concentrations of alkali metal nitrates. A process for extracting technetium values from an aqueous alkaline solution containing at least one alkali metal hydroxide and at least one alkali metal nitrate comprises the steps of: contacting the aqueous alkaline solution with a solvent consisting of a crown ether in a diluent, the diluent being a water-immiscible organic liquid in which the crown ether is soluble, for a period of time sufficient to selectively extract the technetium values from the aqueous alkaline solution into the solvent; separating the solvent containing the technetium values from the aqueous alkaline solution; and stripping the technetium values from the solvent by contacting the solvent with water.

  14. Elution strategies for reversed-phase high-performance liquid chromatography analysis of sucrose alkanoate regioisomers with charged aerosol detection.

    PubMed

    Lie, Aleksander; Pedersen, Lars Haastrup

    2013-10-11

    A broad range of elution strategies for RP-HPLC analysis of sucrose alkanoate regioisomers with CAD was systematically evaluated. The HPLC analyses were investigated using design-of-experiments methodology and analysed by analysis of variance (ANOVA) and regression modelling. Isocratic elutions, isocratic elutions with increased flow, and gradient elutions with step-down profiles and step-up profiles were performed and the chromatographic parameters of the different elution strategies were described by suitable variables. Based on peak resolutions general resolution deviation for multiple peaks (RDm) was developed for sample-independent evaluation of separation of any number of peaks in chromatographic analysis. Isocratic elutions of sucrose alkanoates showed similar relationships between eluent acetonitrile concentration and retention time for all regioisomers of sucrose caprate and sucrose laurate, as confirmed by evaluation of the curvatures using approximate second derivatives and Kendall rank correlation coefficients. Regression modelling and statistical analysis showed that acetonitrile concentration and flow rate were highly significant for both average adjusted retention time and RDm for sucrose laurate. For both responses the effect of changes in acetonitrile concentration was larger than the effect of changes in flow rate, over the ranges studied. Regression modelling of the step-down gradient profiles for the sucrose alkanoates showed that the eluent acetonitrile concentrations were the overall most significant variables for retention time and separation. The models for average adjusted retention time of sucrose caprate and sucrose laurate showed only a few differences in the significance levels of terms, while the models for RDm showed larger differences between the sucrose alkanoates, in both the number of terms and their significance. Efficiency evaluation of elution strategies, in terms of RDm and analysis time, showed that the best results were

  15. An in-vitro evaluation of three types of drug-eluting microspheres loaded with irinotecan.

    PubMed

    Pereira, Philippe L; Plotkin, Stephen; Yu, Renee; Sutter, Allison; Wu, Yue; Sommer, Christof M; Cruise, Gregory M

    2016-10-01

    To compare the mechanical and chemical properties of three commercially available microspheres loaded with irinotecan. LifePearl (200 µm), DC Bead (100-300 µm), and Tandem (100 µm) microspheres were loaded with irinotecan. For loading, elution, and stability determinations, irinotecan concentrations were quantified using validated high-performance liquid chromatography methods. In-vitro elution was performed over 24 h using a USP 4 dissolution apparatus. Diameter measurements were performed using light microscopy. Time in suspension was considered as the time required for the microspheres to vacate 1/3 of the volume. All three microsphere types rapidly loaded irinotecan, with more than 95% loading at 1 h. In-vitro elution of irinotecan was rapid for LifePearl and DC Bead microspheres, with more than 98% elution at 1 h, and delayed for Tandem microspheres, with about 70% elution at 6 h. After loading with irinotecan, the average diameter of LifePearl and DC Bead microspheres was reduced by 9 and 18%, respectively, and was unchanged for Tandem microspheres. All three microsphere types lost 4-6% of the loaded irinotecan almost immediately upon placement in contrast: water and contrast: 5% dextrose, but further losses were minimal over 2 weeks. LifePearl microspheres remained longer in suspension (392±23 s) compared with DC Bead (154±13 s, P<0.001) and Tandem (198±19 s, P<0.001) microspheres. All three microsphere types load irinotecan rapidly. LifePearl and DC Bead microspheres elute irinotecan rapidly. Elution is delayed with Tandem microspheres. LifePearl microspheres show the longest time in suspension. PMID:27416270

  16. Osmolarity effects on red blood cell elution in sedimentation field-flow fractionation.

    PubMed

    Assidjo, N E; Chianéa, T; Clarot, I; Dreyfuss, M F; Cardot, P J

    1999-07-01

    Field-flow fractionation (FFF) is an analytical technique particularly suitable for the separation, isolation, and characterization of macromolecules and micrometer- or submicrometer-sized particles. This chromatographic-like methodology can modulate the retention of micron-sized species according to an elution mode described to date as "steric hyperlayer". In such a model, differences in sample species size, density, or other physical parameters make particle selective elution possible depending on the configuration and the operating conditions of the FFF system. Elution characteristics of micron-sized particles of biological origin, such as cells, can be modified using media and carrier phases of different osmolarities. In these media, a cells average size, density, and shape are modified. Therefore, systematic studies of a single reference cell population, red blood cells (RBCs), are performed with 2 sedimentation FFF systems using either gravity (GrFFF) or a centrifugational field (SdFFF). However, in all cases, normal erythrocyte in isotonic suspension elutes as a single peak when fractionated in these systems. With carrier phases of different osmolarities, FFF elution characteristics of RBCs are modified. Retention modifications are qualitatively consistent with the "steric-hyperlayer" model. Such systematic studies confirm the key role of size, density, and shape in the elution mode of RBCs in sedimentation FFF for living, micronsized biological species. Using polymers as an analogy, the RBC population is described as highly "polydisperse". However, this definition must be reconsidered depending on the parameters under concern, leading to a matricial concept: multipolydispersity. It is observed that multipolydispersity modifications of a given RBC population are qualitatively correlated to the eluted sample band width. PMID:10422264

  17. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography.

    PubMed

    Klein, R; Adler, A; Beanlands, R S; Dekemp, R A

    2007-02-01

    A rubidium-82 ((82)Rb) elution system is described for use with positron emission tomography. Due to the short half-life of (82)Rb (76 s), the system physics must be modelled precisely to account for transport delay and the associated activity decay and dispersion. Saline flow is switched between a (82)Sr/(82)Rb generator and a bypass line to achieve a constant-activity elution of (82)Rb. Pulse width modulation (PWM) of a solenoid valve is compared to simple threshold control as a means to simulate a proportional valve. A predictive-corrective control (PCC) algorithm is developed which produces a constant-activity elution within the constraints of long feedback delay and short elution time. The system model parameters are adjusted through a self-tuning algorithm to minimize error versus the requested time-activity profile. The system is self-calibrating with 2.5% repeatability, independent of generator activity and elution flow rate. Accurate 30 s constant-activity elutions of 10-70% of the total generator activity are achieved using both control methods. The combined PWM-PCC method provides significant improvement in precision and accuracy of the requested elution profiles. The (82)Rb elution system produces accurate and reproducible constant-activity elution profiles of (82)Rb activity, independent of parent (82)Sr activity in the generator. More reproducible elution profiles may improve the quality of clinical and research PET perfusion studies using (82)Rb. PMID:17228112

  18. The Influence of Irradiation Time and Layer Thickness on Elution of Triethylene Glycol Dimethacrylate from SDR® Bulk-Fill Composite

    PubMed Central

    Jakubowska, Katarzyna; Chlubek, Dariusz; Buczkowska-Radlińska, Jadwiga

    2016-01-01

    Objective. This study aimed to evaluate triethylene glycol dimethacrylate (TEGDMA) elution from SDR bulk-fill composite. Methods. Three groups of samples were prepared, including samples polymerized in a 4 mm layer for 20 s, in a 4 mm layer for 40 s, and in a 2 mm layer for 20 s. Elution of TEGDMA into 100% ethanol, a 75% ethanol/water solution, and distilled water was studied. The TEGDMA concentration was measured using HPLC. Results. The TEGDMA concentration decreased in the following order: 100% ethanol > 75% ethanol > distilled water. Doubling the energy delivered to the 4 mm thick sample caused decrease (p < 0.05) in TEGDMA elution to distilled water. In ethanol solutions, the energy increase had no influence on TEGDMA elution. Decreasing the sample thickness resulted in decrease (p < 0.05) in TEGDMA elution for all the solutions. Conclusions. The concentration of eluted TEGDMA and the elution time were both strongly affected by the hydrophobicity of the solvent. Doubling the energy delivered to the 4 mm thick sample did not decrease the elution of TEGDMA but did decrease the amount of the monomer available to less aggressive solvents. Elution of TEGDMA was also correlated with the exposed sample surface area. Clinical Relevance. Decreasing the SDR layer thickness decreases TEGDMA elution. PMID:27366742

  19. Properties of multilayer filters

    NASA Technical Reports Server (NTRS)

    Baumeister, P. W.

    1973-01-01

    New methods were investigated of using optical interference coatings to produce bandpass filters for the spectral region 110 nm to 200 nm. The types of filter are: triple cavity metal dielectric filters; all dielectric reflection filters; and all dielectric Fabry Perot type filters. The latter two types use thorium fluoride and either cryolite films or magnesium fluoride films in the stacks. The optical properties of the thorium fluoride were also measured.

  20. Alkaline-resistance model of subtilisin ALP I, a novel alkaline subtilisin.

    PubMed

    Maeda, H; Mizutani, O; Yamagata, Y; Ichishima, E; Nakajima, T

    2001-05-01

    The alkaline-resistance mechanism of the alkaline-stable enzymes is not yet known. To clarify the mechanism of alkaline-resistance of alkaline subtilisin, structural changes of two typical subtilisins, subtilisin ALP I (ALP I) and subtilisin Sendai (Sendai), were studied by means of physicochemical methods. Subtilisin NAT (NAT), which exhibits no alkaline resistance, was examined as a control. ALP I gradually lost its activity, accompanied by protein degradation, but, on the contrary, Sendai was stable under alkaline conditions. CD spectral measurements at neutral and alkaline pH indicated no apparent differences between ALP I and Sendai. A significant difference was observed on measurement of fluorescence emission spectra of the tryptophan residues of ALP I that were exposed on the enzyme surface. The fluorescence intensity of ALP I was greatly reduced under alkaline conditions; moreover, the reduction was reversed when alkaline-treated ALP I was neutralized. The fluorescence spectrum of Sendai remained unchanged. The enzymatic and optical activities of NAT were lost at high pH, indicating a lack of functional and structural stability in an alkaline environment. Judging from these results, the alkaline resistance is closely related to the surface structure of the enzyme molecule. PMID:11328588

  1. Contrasting Effects of Physical Wear on Elution of Two Antibiotics from Orthopedic Cement

    PubMed Central

    Dodds, S.; Akid, R.; Stephenson, J.; Nichol, T.; Banerjee, R. D.; Stockley, I.; Townsend, R.

    2012-01-01

    The use of antibiotics as a supplement to bone cement for the purposes of providing a local release of antibiotics is common practice in arthroplasty surgery and the kinetics of elution of the antibiotics in such systems have been investigated previously. However, in these previous studies no account was taken of the potential effects that wear may have on the elution kinetics of the antibiotic. Here, we have modified an existing wear testing rig to allow the simultaneous study of the elution kinetics of bone cement samples containing antibiotics being subjected to immersion only and immersion and conjoint wear. The results show contrasting effects with two commonly used antibiotics. Bone cement containing daptomycin showed no substantial change in antibiotic elution due to wear, while cement containing gentamicin (the most commonly used antibiotic in this application) in contrast demonstrated a substantial reduction in the rate of antibiotic elution when wear was applied. Scanning electron microscopy revealed a possible explanation for these diverse results, due to wear-induced “sealing” of the surface in conjunction with the crystal morphology of the antibiotic. PMID:22155831

  2. Comparison between sirolimus- and paclitaxel-eluting stent in T-cell subsets redistribution.

    PubMed

    Sardella, Gennaro; De Luca, Leonardo; Di Roma, Angelo; De Persio, Giovanni; Conti, Giulia; Paroli, Marino; Fedele, Francesco

    2006-02-15

    We sought to investigate the effects of 2 different coronary drug-eluting stents on the distribution of central or effector memory T cells circulating in the coronary sinus of patients with coronary artery disease who underwent percutaneous coronary revascularization. We randomly assigned 43 patients (mean age 65.4 +/- 4.3 years; 34 men) presenting with stable coronary disease and angiographically proved stenosis of the left anterior descending artery to treatment with sirolimus- or paclitaxel-eluting stents. Heparinized blood samples were obtained from the coronary sinus before and 20 minutes after stent implantation. Analysis of surface phenotype was performed by 4-color flow cytometry, and data are expressed as the percentage of positive cells. The percentages of CD8+ and CD4+ effector memory T cells, as defined by the CD3+CD45RO+CD27- phenotype, were significantly reduced in patients who received a sirolimus-eluting stent compared with the basal values. Conversely, the percentages of CD8+, but not CD4+, central memory T cells (CD3+CD45RO+CD27+) were increased in the same treatment group after the revascularization procedure. No changes in the percentages of memory T-cell populations in the paclitaxel-eluting stent group were observed. These findings show that sirolimus-eluting stents rapidly induced a redistribution of memory T lymphocytes, with a significant decrease of proinflammatory effector memory T cells circulating within the coronary sinus. PMID:16461044

  3. Impact of ultrasonic time on hot water elution of severely biodegraded heavy oil from weathered soils.

    PubMed

    Ji, Guodong; Sui, Xin

    2010-07-15

    An ultrasound-enhanced elution system employing water at a temperature of 70 degrees C was used to remedy weathered soils contaminated with severely biodegraded heavy oil (SBHO). The effect of varying the ultrasonic irradiation time from 0 to 1800 s on the elution of SBHO and three characteristic biomarkers (C(26-34) 17alpha 25-norhopanes, C(26-28) TAS, and C(27-29) MTAS) was analyzed using GC/MS, scanning electron microscopy (SEM), and X-ray diffraction (XRD). Elution of the three biomarkers was closely related to the carbon number of the marker. C(26-34) 17alpha 25-norhopanes and C(26-28) TAS species with higher carbon numbers and C(27-29) MTAS species with lower carbon numbers were more readily eluted using sonication times of 1080-1800 s, while smaller TAS homologs were more readily eluted after sonication times of 0-360 s. SEM images of samples treated for longer periods revealed larger "bare patches" on the soil surface. The results of XRD and energy spectroscopy experiments indicated that ultrasound irradiation for 1080 s negatively affected the deposition of CaCO(3), but overall improved the mineral and chemical compositions of treated soils and removal of SBHO. PMID:20347521

  4. Aluminum elution and precipitation in glass vials: effect of pH and buffer species.

    PubMed

    Ogawa, Toru; Miyajima, Makoto; Wakiyama, Naoki; Terada, Katsuhide

    2015-02-01

    Inorganic extractables from glass vials may cause particle formation in the drug solution. In this study, the ability of eluting Al ion from borosilicate glass vials, and tendencies of precipitation containing Al were investigated using various pHs of phosphate, citrate, acetate and histidine buffer. Through heating, all of the buffers showed that Si and Al were eluted from glass vials in ratios almost the same as the composition of borosilicate glass, and the amounts of Al and Si from various buffer solutions at pH 7 were in the following order: citrate > phosphate > acetate > histidine. In addition, during storage after heating, the Al concentration at certain pHs of phosphate and acetate buffer solution decreased, suggesting the formation of particles containing Al. In citrate buffer, Al did not decrease in spite of the high elution amount. Considering that the solubility profile of aluminum oxide and the Al eluting profile of borosilicate glass were different, it is speculated that Al ion may be forced to leach into the buffer solution according to Si elution on the surface of glass vials. When Al ions were added to the buffer solutions, phosphate, acetate and histidine buffer showed a decrease of Al concentration during storage at a neutral range of pHs, indicating the formation of particles containing Al. In conclusion, it is suggested that phosphate buffer solution has higher possibility of forming particles containing Al than other buffer solutions. PMID:24261406

  5. A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease

    PubMed Central

    Bennett, Johan; Dubois, Christophe

    2013-01-01

    The development of coronary stents represents a major step forward in the treatment of obstructive coronary artery disease since the introduction of percutaneous coronary intervention. The initial enthusiasm for bare metal stents was, however, tempered by a significant incidence of in-stent restenosis, the manifestation of excessive neointima hyperplasia within the stented vessel segment, ultimately leading to target vessel revascularization. Later, drug-eluting stents, with controlled local release of antiproliferative agents, consistently reduced this need for repeat revascularization. In turn, the long-term safety of first-generation drug-eluting stents was brought into question with the observation of an increased incidence of late stent thrombosis, often presenting as myocardial infarction or sudden death. Since then, new drugs, polymers, and platforms for drug elution have been developed to improve stent safety and preserve efficacy. Development of a novel platinum chromium alloy with high radial strength and high radiopacity has enabled the design of a new, thin-strut, flexible, and highly trackable stent platform, while simultaneously improving stent visibility. Significant advances in polymer coating, serving as a drug carrier on the stent surface, and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation drug-eluting stents. This review will provide an overview of the novel platinum chromium everolimus-eluting stents that are currently available. The clinical data from major clinical trials with these devices will be summarized and put into perspective. PMID:23818756

  6. ARRANGEMENT FOR REPLACING FILTERS

    DOEpatents

    Blomgren, R.A.; Bohlin, N.J.C.

    1957-08-27

    An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.

  7. Corrosion resistant filter unit

    SciTech Connect

    Gentry, J.M.

    1992-02-18

    This patent describes a fluid filter assembly adapted for the filtration of corrosive fluid to be injected into a well bore at pressure levels which may exceed 10,000 pounds per square. It comprises: a frame assembly for the mounting of a portion of the fluid filter assembly therein, the frame assembly; filter pods, the plurality of filter pods forming at least two banks of filter pods, each bank having at least two filter pods therein, each bank of the filter pods being supported by one or more the supports of the plurality of supports secured to selected struts of the frame assembly; an inlet manifold to direct the corrosive fluid to the plurality of filter pods, the inlet manifold being interconnected to the banks of filter pods formed by the filter pods whereby flow of the corrosive fluid can be directed to each bank of the filter pods; an outlet manifold to direct the corrosive fluid from the filter pods, the outlet manifold being interconnected to the banks of filter pods formed by the filter pods; a first valve means to control the flow of the corrosive fluid between banks of filter pods formed by the filter pods whereby the flow of the corrosive fluid can be selectively directed to each bank of the filter pods; a second valve means to selectively control the flow of the corrosive fluid between the inlet manifold and the outlet manifold; and union means for interconnecting the filter pods, inlet manifold and outlet manifold, each of the union means including mechanical connection means and internal seal means for isolating the corrosive fluids from the mechanical connection means.

  8. Inorganic-organic separators for alkaline batteries

    NASA Technical Reports Server (NTRS)

    Sheibley, D. W. (Inventor)

    1978-01-01

    A flexible separator is reported for use between the electrodes of Ni-Cd and Ni-Zn batteries using alkaline electrolytes. The separator was made by coating a porous substrate with a battery separator composition. The coating material included a rubber-based resin copolymer, a plasticizer and inorganic and organic fillers which comprised 55% by volume or less of the coating as finally dried. One or more of the filler materials, whether organic or inorganic, is preferably active with the alkaline electrolyte to produce pores in the separator coating. The plasticizer was an organic material which is hydrolyzed by the alkaline electrolyte to improve conductivity of the separator coating.

  9. Process for extracting technetium from alkaline solutions

    DOEpatents

    Moyer, Bruce A.; Sachleben, Richard A.; Bonnesen, Peter V.

    1995-01-01

    A process for extracting technetium values from an aqueous alkaline solution containing at least one alkali metal hydroxide and at least one alkali metal nitrate, the at least one alkali metal nitrate having a concentration of from about 0.1 to 6 molar. The solution is contacted with a solvent consisting of a crown ether in a diluent for a period of time sufficient to selectively extract the technetium values from the aqueous alkaline solution. The solvent containing the technetium values is separated from the aqueous alkaline solution and the technetium values are stripped from the solvent.

  10. Rigid porous filter

    DOEpatents

    Chiang, Ta-Kuan; Straub, Douglas L.; Dennis, Richard A.

    2000-01-01

    The present invention involves a porous rigid filter including a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulates from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulates. The present filter has the advantage of requiring fewer filter elements due to the high surface area-to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

  11. In vitro tobramycin elution analysis from a novel beta-tricalcium phosphate-silicate-xerogel biodegradable drug-delivery system.

    PubMed

    DiCicco, Michael; Goldfinger, Aaron; Guirand, Felix; Abdullah, Aquill; Jansen, Susan A

    2004-07-15

    This in vitro research analyzed local tobramycin elution characteristics from a novel, biodegradable drug delivery system, consisting of a beta-TCP bone substitute, VITOSS trade mark, encapsulated with silicate xerogel prepared by the sol-gel process. Tobramycin elution from silicate-xerogel-encapsulated VITOSS was compared directly with non-silicate-xerogel-encapsulated VITOSS to assess whether xerogels are effective in delivering greater tobramycin quantities in a controllable, sustained manner crucial for microbial inhibition. Tobramycin elution characteristics indicate an initial release maximum during the first 24 h that diminishes gradually several days after impregnation. The copious tobramycin quantity eluted from the VITOSS/silicate-xerogel systems is attributed to various factors: the intrinsic ultraporosity and hydrophilicity of VITOSS, the ability of tobramycin to completely dissolve in aqueous media, tobramycin complexation with highly polar SO(4) (2-) salts that further assist dissolution, and ionic exchanges between VITOSS and the environment. Silicate-xerogel-encapsulated VITOSS eluted 60.65 and 61.31% of impregnated tobramycin, whereas non-silicate-xerogel-encapsulated VITOSS eluted approximately one-third less impregnated tobramycin, at 21.53 and 23.60%. These results suggest that silicate xerogel optimizes tobramycin elution because of its apparent biodegradability. This mechanism occurs through xerogel superficial acidic sites undergoing exchanges with various ions present in the leaching buffer. Tobramycin elution kinetics were evaluated, and demonstrate that first-order elution rate constants are considerably less when silicate xerogels are employed, following a more uniform exponential decay-type mechanism, thus bolstering controlled release. Overall, tobramycin elution rates adhere to linear-type Higuchi release profiles. Elution rate constants are initially first order, and taper into zero-order elution kinetics in the latter stages of

  12. Filter type gas sampler with filter consolidation

    DOEpatents

    Miley, Harry S.; Thompson, Robert C.; Hubbard, Charles W.; Perkins, Richard W.

    1997-01-01

    Disclosed is an apparatus for automatically consolidating a filter or, more specifically, an apparatus for drawing a volume of gas through a plurality of sections of a filter, whereafter the sections are subsequently combined for the purpose of simultaneously interrogating the sections to detect the presence of a contaminant.

  13. Filter type gas sampler with filter consolidation

    DOEpatents

    Miley, H.S.; Thompson, R.C.; Hubbard, C.W.; Perkins, R.W.

    1997-03-25

    Disclosed is an apparatus for automatically consolidating a filter or, more specifically, an apparatus for drawing a volume of gas through a plurality of sections of a filter, where after the sections are subsequently combined for the purpose of simultaneously interrogating the sections to detect the presence of a contaminant. 5 figs.

  14. Method and apparatus for selective filtering of ions

    DOEpatents

    Page, Jason S.; Tang, Keqi; Smith, Richard D.

    2009-04-07

    An adjustable, low mass-to-charge (m/z) filter is disclosed employing electrospray ionization to block ions associated with unwanted low m/z species from entering the mass spectrometer and contributing their space charge to down-stream ion accumulation steps. The low-mass filter is made by using an adjustable potential energy barrier from the conductance limiting terminal electrode of an electrodynamic ion funnel, which prohibits species with higher ion mobilities from being transmitted. The filter provides a linear voltage adjustment of low-mass filtering from m/z values from about 50 to about 500. Mass filtering above m/z 500 can also be performed; however, higher m/z species are attenuated. The mass filter was evaluated with a liquid chromatography-mass spectrometry analysis of an albumin tryptic digest and resulted in the ability to block low-mass, "background" ions which account for 40-70% of the total ion current from the ESI source during peak elution.

  15. Some design considerations for polymer-free drug-eluting stents: a mathematical approach.

    PubMed

    McGinty, Sean; Vo, Tuoi T N; Meere, Martin; McKee, Sean; McCormick, Christopher

    2015-05-01

    In this paper we provide the first model of drug elution from polymer-free arterial drug-eluting stents. The generalised model is capable of predicting drug release from a number of polymer-free systems including those that exhibit nanoporous, nanotubular and smooth surfaces. We derive analytical solutions which allow us to easily determine the important parameters that control drug release. Drug release profiles are provided, and we offer design recommendations so that the release profile may be tailored to achieve the desired outcome. The models presented here are not specific to drug-eluting stents and may also be applied to other biomedical implants that use nanoporous surfaces to release a drug. PMID:25712386

  16. Drug-eluting stents: role of stent design, delivery vehicle, and drug selection.

    PubMed

    Rodgers, Campbell D K

    2002-01-01

    Increasing focus has recently been directed toward the different parameters of drug-eluting stents-stent design, delivery-vehicle materials, and drug properties-and the manner in which each of these elements may affect the function of the stents. Several specific characteristics of design may affect restenosis, although design optimization often presents a choice between acute procedural success and long-term biological stability. The influence of design parameters such as strut thickness and cell configuration is described. Polymer material has frequently been used to coat drug-eluting stents, although some agents, such as paclitaxel, can be attached directly to the stent's surface, obviating the need for a polymer layer. The properties of agents used in drug-eluting stents and how those properties affect delivery and long-term outcome are discussed, as is the influence of the disease state of the target vessel on stent safety and efficacy. PMID:12478230

  17. Modeling smooth muscle cell proliferation of coronary artery expanded with a drug eluting stent

    NASA Astrophysics Data System (ADS)

    Lyu, Suping

    2010-03-01

    The drug eluting coronary stent is for the treatment of narrowed coronary artery. A high strength balloon is used to open the narrowed vessel and leave behind a tiny metal mesh, or stent, to mechanically prevent the vessel from re-narrowing and biologically slow down proliferation of the smooth muscle cells. However, the drug eluting stents that had better performance also more seriously prevented the healing processes of the vessels, which could cause serious thrombotic reactions. In this study, we assume the healing process is controlled by proper proliferation of smooth cells. We also assume that the inflammation reactions and mechanical traction drive the smooth muscle cells to proliferate while the drug loaded in the stents drives the processes at the opposite direction. Numerical calculation was applied to the system. The drug distribution and elution durations, inflammation reactions and mechanical traction were discussed.

  18. The elution of certain protein affinity tags with millimolar concentrations of diclofenac.

    PubMed

    Baliova, Martina; Juhasova, Anna; Jursky, Frantisek

    2015-12-01

    Diclofenac (2-[(2, 6-dichlorophenyl)amino] benzeneacetic acid) is a sparingly soluble, nonsteroidal anti-inflammatory drug therapeutically acting at low micromolar concentrations. In pH range from 8 to 11, its aqueous solubility can be increased up to 200 times by the presence of counter ions such as sodium. Our protein interaction studies revealed that a millimolar concentration of sodium diclofenac is able to elute glutathione S-transferase (GST), cellulose binding protein (CBD), and maltose binding protein (MBP) but not histidine-tagged or PDZ-tagged proteins from their affinity resins. The elution efficiency of diclofenac is comparable with the eluting agents normally used at similar concentrations. Native gel electrophoresis of sodium diclofenac-treated proteins showed that the interaction is non-covalent and non-denaturing. These results suggest that sodium diclofenac, in addition to its pharmaceutical applications, can also be exploited as a lead for the development of new proteomics reagents. PMID:26551210

  19. Controversies in the use & implementation of drug-eluting stent technology

    PubMed Central

    Itagaki, Brandon K.; Brar, Somjot S.

    2012-01-01

    The introduction of drug eluting stents has resulted in dramatic reductions in the rates of restenosis and the need for repeat revascularization. In the last several years, concern has been raised regarding the long-term safety of this technology, particularly in the area of late restenosis and stent thrombosis. The development of newer anti-restenotic drug coatings, biodegradable polymers and even completely bioabsorbable stents offer the potential to address these limitations. Additional questions that have recently come to the forefront include the optimal duration of dual antiplatelet therapy, the use of platelet reactivity assays and genetic testing and drug eluting stent use in the treatment of acute myocardial infarction. This article will attempt to address these and other areas of controversy in the use and implementation of drug eluting stents. PMID:23391788

  20. Cordierite silicon nitride filters

    SciTech Connect

    Sawyer, J.; Buchan, B. ); Duiven, R.; Berger, M. ); Cleveland, J.; Ferri, J. )

    1992-02-01

    The objective of this project was to develop a silicon nitride based crossflow filter. This report summarizes the findings and results of the project. The project was phased with Phase I consisting of filter material development and crossflow filter design. Phase II involved filter manufacturing, filter testing under simulated conditions and reporting the results. In Phase I, Cordierite Silicon Nitride (CSN) was developed and tested for permeability and strength. Target values for each of these parameters were established early in the program. The values were met by the material development effort in Phase I. The crossflow filter design effort proceeded by developing a macroscopic design based on required surface area and estimated stresses. Then the thermal and pressure stresses were estimated using finite element analysis. In Phase II of this program, the filter manufacturing technique was developed, and the manufactured filters were tested. The technique developed involved press-bonding extruded tiles to form a filter, producing a monolithic filter after sintering. Filters manufactured using this technique were tested at Acurex and at the Westinghouse Science and Technology Center. The filters did not delaminate during testing and operated and high collection efficiency and good cleanability. Further development in areas of sintering and filter design is recommended.

  1. Alternate Methods for Eluting Cesium from Spherical Resorcinol-Formaldehyde Resin

    SciTech Connect

    Taylor, Paul Allen; Johnson, Heather Lauren

    2009-02-01

    A small-column ion exchange (SCIX) system has been proposed for removing cesium from the supernate and dissolved salt solutions in the high-level-waste tanks at the Savannah River Site (SRS). The SCIX system could use either crystalline silicotitanate (CST), an inorganic, non-regenerable sorbent, or spherical resorcinol-formaldehyde (RF), a new regenerable resin, to remove cesium from the waste solutions. The baseline method for eluting the cesium from the RF resin uses 15 bed volumes (BV) of 0.5 M nitric acid (HNO{sub 3}). The nitric acid eluate, containing the radioactive cesium, would be combined with the sludge from the waste tanks and would be converted into glass at the Defense Waste Processing Facility (DWPF) at SRS. The amount of nitric acid that would be used to elute the RF resin, using the current elution protocol, exceeds the capacity of DWPF to destroy the nitrate ions and maintain the required chemical reducing environment in the glass melt. Installing a denitration evaporator at SRS is technically feasible but would add considerable cost to the project. Alternate methods for eluting the resin have been tested, including using lower concentrations of nitric acid, other acids, and changing the flow regimes. About 4 BV of 0.5 M HNO{sub 3} are required to remove the sodium (titrate the resin) and most of the cesium from the resin, so the bulk of the acid used for the baseline elution method removes a very small quantity of cesium from the resin. A summary of the elution methods that have been tested are listed.

  2. Medicare and Private Insurance Variations in New Medical Technology: The Case of Drug Eluting Stents

    PubMed Central

    Bayindir, Esra Eren; Mandic, Pinar Karaca

    2016-01-01

    Importance Little is known about the geographic and hospital variations of the new medical technologies in Medicare. Even less is known about these variations for the privately insured. Objective To examine geographic and hospital variations in the diffusion of drug eluting stents, comparing Medicare and privately insured populations. Design Retrospective analyses of discharges from the State Inpatient Databases for 11 states (2004–2005) supplemented with data on hospital characteristics from the American Hospital Association Annual Survey. Setting/participants Study sample included discharges with percutaneous coronary intervention (PCI) procedures that involved a cardiac stent. Exposure Insurance type: Medicare versus private insurance. Main outcome Use of a drug eluting stent during the PCI was our outcome variable. We estimated linear probability models at the discharge level that related our outcome variable to patient and hospital characteristics separately for Medicare and private insurance. To examine variations across hospital referral regions (HRRs) and across hospitals, our models included HRR and hospital indicators respectively. Results Our analysis included 390,649 records (237,991 Medicare, 152,658 private insurance). We found large HRR variations in the use of drug eluting stents in 2004 for both payer types, the year after drug eluting stents were approved (adjusted CoV: 0.35 (Medicare); 0.24 (Private Insurance)). We also found large hospital variations in 2004 (adjusted CoV: 0.32 (Medicare); 0.29 (Private Insurance)). Between 2004 and 2005, adjusted HRR and hospital variations decreased across both payer types, suggesting that practice styles converged as the drug eluting stents diffused and became more common. Finally, adjusted drug eluting stent rates were highly correlated both at the HRR and hospital level across payer types. Conclusion Our findings are consistent with the hypothesis that private insurance closely follows the lead of

  3. Improved blood compatibility of rapamycin-eluting stent by incorporating curcumin.

    PubMed

    Pan, C J; Tang, J J; Shao, Z Y; Wang, J; Huang, N

    2007-09-01

    This paper dealt with improving the blood compatibility of the rapamycin-eluting stent by incorporating curcumin. The rapamycin- and rapamycin/curcumin-loaded PLGA (poly(d,l-lactic acid-co-glycolic acid)) coatings were fabricated onto the surface of the stainless steel stents using an ultrasonic atomization spray method. The structure of the coating films was characterized by Fourier transform infrared spectroscopy (FTIR). The optical microscopy and scanning electron microscopy (SEM) images of the drug-eluting stents indicated that the surface of all drug-eluting stents was very smooth and uniform, and there were not webbings and "bridges" between struts. There were not any cracks and delaminations on stent surface after expanded by the angioplasty balloon. The in vitro platelet adhesion and activation were investigated by static platelet adhesion test and GMP140 (P-selection), respectively. The clotting time was examined by activated partially prothromplastin time (APTT) test. The fibrinogen adsorption on the drug-loaded PLGA films was evaluated by enzyme-linked immunosorbent assay (ELISA). All obtained data showed that incorporating curcumin in rapamycin-loaded PLGA coating can significantly decrease platelet adhesion and activation, prolong APTT clotting time as well as decrease the fibrinogen adsorption. All results indicated that incorporating curcumin in rapamycin-eluting coating obviously improve the blood compatibility of rapamycin-eluting stents. It was suggested that it may be possible to develop a drug-eluting stent which had the characteristics of not only good anti-proliferation but also improved anticoagulation. PMID:17540543

  4. Drug-eluting stents in the management of peripheral arterial disease

    PubMed Central

    Bosiers, Marc; Cagiannos, Catherine; Deloose, Koen; Verbist, Jürgen; Peeters, Patrick

    2008-01-01

    Since major meta-analyses of randomized controlled trials in interventional cardiology showed the potential of drug-eluting stents in decreasing restenosis and reintervention rates after coronary artery stenting, one of the next steps in the treatment of arterial occlusive disease is the transfer of the active coating technology towards peripheral arterial interventions. In this manuscript, we aim to provide a literature overview on available peripheral (lower limb, renal, and supra-aortic) drug-eluting stent applications, debate the cost implications, and give recommendations for future treatment strategies. PMID:18827906

  5. Involvement of COX-2 in nickel elution from a wire implanted subcutaneously in mice.

    PubMed

    Sato, Taiki; Kishimoto, Yu; Asakawa, Sanki; Mizuno, Natsumi; Hiratsuka, Masahiro; Hirasawa, Noriyasu

    2016-07-01

    Many types of medical alloys include nickel (Ni), and the elution of Ni ions from these materials causes toxicities and inflammation. We have previously reported that inflammation enhances Ni elution, although the molecular mechanisms underlying this effect remain unclear. In this study, we investigated how inflammatory responses enhanced Ni elution in a wire-implantation mouse model. Subcutaneous implantation of Ni wire induced the expression of cyclooxygenase-2 (COX-2) and microsomal prostaglandin E synthase-1 (mPGES-1) mRNA in the surrounding tissues. Immunostaining analysis showed that cells expressing COX-2 were mainly fibroblast-like cells 8h after implantation of a Ni wire, but were mainly infiltrated leukocytes at 24h. NiCl2 induced the expression of COX-2 mRNA in primary fibroblasts, neutrophils, RAW 264 cells, and THP-1 cells, indicating that Ni ions can induce COX-2 expression in various types of cells. The elution of Ni ions from the implanted Ni wire at 8h was reduced by dexamethasone (Dex), indomethacin (Ind), or celecoxib (Cel) treatment. Ni wire implantation induced an increase in mRNA levels for anaerobic glycolytic pathway components glucose transporter 1 (GLUT1), hexokinase 2 (HK2), lactate dehydrogenase A (LDHA), and monocarboxylate transporter 4 (MCT4); the expression of these genes was also inhibited by Dex, Ind, and Cel. In primary fibroblasts, the expression of these mRNAs and the production of lactate were induced by NiCl2 and further potentiated by PGE2. Furthermore, Ni wire-induced infiltration of inflammatory leukocytes was significantly reduced by Dex, Ind, or Cel. Depletion of neutrophils with a specific antibody caused reduction of both leukocyte infiltration and Ni elution. These results indicate that Ni ions eluted from wire induced COX-2 expression, which further promoted elution of Ni ions by increasing lactate production and leukocyte infiltration. Since COX inhibitors and Dex reduced the elution of Ni ions, these drugs may be

  6. Two Cases of Immediate Stent Fracture after Zotarolimus-Eluting Stent Implantation

    PubMed Central

    Lee, Pil Hyung; Lee, Seung-Whan; Lee, Jong-Young; Kim, Young-Hak; Lee, Cheol Whan; Park, Duk-Woo; Park, Seong-Wook

    2015-01-01

    Drug-eluting stent (DES) implantation is currently the standard treatment for various types of coronary artery disease. However, previous reports indicate that stent fractures, which usually occur after a period of time from the initial DES implantation, have increased during the DES era; stent fractures can contribute to unfavorable events such as in-stent restenosis and stent thrombosis. In our present report, we describe two cases of zotarolimus-eluting stent fracture: one that was detected six hours after implementation, and the other case that was detected immediately after deployment. Both anatomical and technical risk factors contributed to these unusual cases of immediate stent fracture. PMID:25653706

  7. A case of coronary rupture and pseudoaneurysm formation after fracture of implanted paclitaxel-eluting stents.

    PubMed

    Kawai, Yasuyuki; Kitayama, Michihiko; Akao, Hironobu; Motoyama, Atsushi; Tsuchiya, Taketsugu; Kajinami, Kouji

    2016-07-01

    A 48-year-old man who had undergone implantation of two paclitaxel-eluting stents (PESs) at the right coronary artery was admitted to our hospital with progressive dyspnea. In the coronary care unit, he developed cardiogenic shock due to cardiac tamponade treated by pericardiocentesis. A coronary angiogram showed a large pseudoaneurysm at the site of the previously implanted stents, suggesting coronary rupture due to implanted stent fracture. The pseudoaneurysm was completely sealed by polytetrafluoroethylene-covered stent implantation. Although this case is very rare, coronary rupture by stent fracture should be considered when cardiac tamponade occurs after drug-eluting stent implantation, especially PES. PMID:25998891

  8. Composite seal reduces alkaline battery leakage

    NASA Technical Reports Server (NTRS)

    Clatterbuck, C. H.; Plitt, K. F.

    1965-01-01

    Composite seal consisting of rubber or plastic washers and a metal washer reduces alkaline battery leakage. Adhesive is applied to each washer interface, and the washers are held together mechanically.

  9. Bag filters for TPP

    SciTech Connect

    L.V. Chekalov; Yu.I. Gromov; V.V. Chekalov

    2007-05-15

    Cleaning of TPP flue gases with bag filters capable of pulsed regeneration is examined. A new filtering element with a three-dimensional filtering material formed from a needle-broached cloth in which the filtration area, as compared with a conventional smooth bag, is increased by more than two times, is proposed. The design of a new FRMI type of modular filter is also proposed. A standard series of FRMI filters with a filtration area ranging from 800 to 16,000 m{sup 2} is designed for an output more than 1 million m{sub 3}/h of with respect to cleaned gas. The new bag filter permits dry collection of sulfur oxides from waste gases at TPP operating on high-sulfur coals. The design of the filter makes it possible to replace filter elements without taking the entire unit out of service.

  10. HEPA filter monitoring program

    NASA Astrophysics Data System (ADS)

    Kirchner, K. N.; Johnson, C. M.; Aiken, W. F.; Lucerna, J. J.; Barnett, R. L.; Jensen, R. T.

    1986-07-01

    The testing and replacement of HEPA filters, widely used in the nuclear industry to purify process air, are costly and labor-intensive. Current methods of testing filter performance, such as differential pressure measurement and scanning air monitoring, allow determination of overall filter performance but preclude detection of incipient filter failure such as small holes in the filters. Using current technology, a continual in-situ monitoring system was designed which provides three major improvements over current methods of filter testing and replacement. The improvements include: cost savings by reducing the number of intact filters which are currently being replaced unnecessarily; more accurate and quantitative measurement of filter performance; and reduced personnel exposure to a radioactive environment by automatically performing most testing operations.

  11. Novel Backup Filter Device for Candle Filters

    SciTech Connect

    Bishop, B.; Goldsmith, R.; Dunham, G.; Henderson, A.

    2002-09-18

    The currently preferred means of particulate removal from process or combustion gas generated by advanced coal-based power production processes is filtration with candle filters. However, candle filters have not shown the requisite reliability to be commercially viable for hot gas clean up for either integrated gasifier combined cycle (IGCC) or pressurized fluid bed combustion (PFBC) processes. Even a single candle failure can lead to unacceptable ash breakthrough, which can result in (a) damage to highly sensitive and expensive downstream equipment, (b) unacceptably low system on-stream factor, and (c) unplanned outages. The U.S. Department of Energy (DOE) has recognized the need to have fail-safe devices installed within or downstream from candle filters. In addition to CeraMem, DOE has contracted with Siemens-Westinghouse, the Energy & Environmental Research Center (EERC) at the University of North Dakota, and the Southern Research Institute (SRI) to develop novel fail-safe devices. Siemens-Westinghouse is evaluating honeycomb-based filter devices on the clean-side of the candle filter that can operate up to 870 C. The EERC is developing a highly porous ceramic disk with a sticky yet temperature-stable coating that will trap dust in the event of filter failure. SRI is developing the Full-Flow Mechanical Safeguard Device that provides a positive seal for the candle filter. Operation of the SRI device is triggered by the higher-than-normal gas flow from a broken candle. The CeraMem approach is similar to that of Siemens-Westinghouse and involves the development of honeycomb-based filters that operate on the clean-side of a candle filter. The overall objective of this project is to fabricate and test silicon carbide-based honeycomb failsafe filters for protection of downstream equipment in advanced coal conversion processes. The fail-safe filter, installed directly downstream of a candle filter, should have the capability for stopping essentially all particulate

  12. MST Filterability Tests

    SciTech Connect

    Poirier, M. R.; Burket, P. R.; Duignan, M. R.

    2015-03-12

    The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO2, and NaNO3) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

  13. Technetium recovery from high alkaline solution

    DOEpatents

    Nash, Charles A.

    2016-07-12

    Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.

  14. Alkaline tolerant dextranase from streptomyces anulatus

    DOEpatents

    Decker, Stephen R.; Adney, William S.; Vinzant, Todd B.; Himmel, Michael E.

    2003-01-01

    A process for production of an alkaline tolerant dextranase enzyme comprises culturing a dextran-producing microorganism Streptomyces anulatus having accession no. ATCC PTA-3866 to produce an alkaline tolerant dextranase, Dex 1 wherein the protein in said enzyme is characterized by a MW of 63.3 kDa and Dex 2 wherein its protein is characterized by a MW of 81.8 kDa.

  15. Evaluation of the alkaline electrolysis of zinc

    SciTech Connect

    Meisenhelder, J.H.; Brown, A.P.; Loutfy, R.O.; Yao, N.P.

    1981-05-01

    The alkaline leach and electrolysis process for zinc production is compared to the conventional acid-sulfate process in terms of both energy saving and technical merit. In addition, the potential for industrial application of the alkaline process is discussed on the basis of present market conditions, possible future zinc market scenarios, and the probability of increased secondary zinc recovery. In primary zinc production, the energy-saving potential for the alkaline process was estimated to be greater than 10%, even when significantly larger electrolysis current densities than those required for the sulfate process are used. The principal technical advantages of the alkaline process are that it can handle low-grade, high-iron-content or oxidized ores (like most of those found in the US) in a more cost- and energy-efficient manner than can the sulfate process. Additionally, in the electrowinning operation, the alkaline process should be technically superior because a dendritic or sponge deposit is formed that is amenable to automated collection without interruption of the electrolysis. Also, use of the higher current densities would result in significant capital cost reductions. Alkaline-based electrolytic recovery processes were considered for the recycling of zinc from smelter baghouse dusts and from the potential source of nickel/zinc electric-vehicle batteries. In all comparisons, an alkaline process was shown to be technically superior and, particularly for the baghouse dusts, energetically and economically superior to alternatively proposed recovery methods based on sulfate electrolysis. It is concluded that the alkaline zinc method is an important alternative technology to the conventional acid zinc process. (WHK)

  16. Survey of digital filtering

    NASA Technical Reports Server (NTRS)

    Nagle, H. T., Jr.

    1972-01-01

    A three part survey is made of the state-of-the-art in digital filtering. Part one presents background material including sampled data transformations and the discrete Fourier transform. Part two, digital filter theory, gives an in-depth coverage of filter categories, transfer function synthesis, quantization and other nonlinear errors, filter structures and computer aided design. Part three presents hardware mechanization techniques. Implementations by general purpose, mini-, and special-purpose computers are presented.

  17. Nonlinear optimal semirecursive filtering

    NASA Astrophysics Data System (ADS)

    Daum, Frederick E.

    1996-05-01

    This paper describes a new hybrid approach to filtering, in which part of the filter is recursive but another part in non-recursive. The practical utility of this notion is to reduce computational complexity. In particular, if the non- recursive part of the filter is sufficiently small, then such a filter might be cost-effective to run in real-time with computer technology available now or in the future.

  18. Alkaline Water and Longevity: A Murine Study

    PubMed Central

    Magro, Massimiliano; Corain, Livio; Ferro, Silvia; Baratella, Davide; Bonaiuto, Emanuela; Terzo, Milo; Corraducci, Vittorino; Salmaso, Luigi; Vianello, Fabio

    2016-01-01

    The biological effect of alkaline water consumption is object of controversy. The present paper presents a 3-year survival study on a population of 150 mice, and the data were analyzed with accelerated failure time (AFT) model. Starting from the second year of life, nonparametric survival plots suggest that mice watered with alkaline water showed a better survival than control mice. Interestingly, statistical analysis revealed that alkaline water provides higher longevity in terms of “deceleration aging factor” as it increases the survival functions when compared with control group; namely, animals belonging to the population treated with alkaline water resulted in a longer lifespan. Histological examination of mice kidneys, intestine, heart, liver, and brain revealed that no significant differences emerged among the three groups indicating that no specific pathology resulted correlated with the consumption of alkaline water. These results provide an informative and quantitative summary of survival data as a function of watering with alkaline water of long-lived mouse models. PMID:27340414

  19. Performed surfactant-optimized aqueous alkaline flood

    SciTech Connect

    Thigpen, D.R.; Lawson, J.B.; Nelson, R.C.

    1991-11-26

    This paper describes improvement in a process for recovering oil from an acidic oil reservoir by injecting an aqueous alkaline solution comprising water, sodium chloride, and alkaline material for reacting with the reservoir oil forming a petroleum acid soap to form an in-situ surfactant system. The improvement comprises: selecting a preformed cosurfactant which is soluble in both the aqueous solution and the reservoir oil and has a solubility ratio which is grater than the solubility ratio of the petroleum acid soap where the solubility ratio is the ratio of solubility in the aqueous alkaline solution to the solubility in the reservoir oil; combining with the alkaline solution an amount of the preformed cosurfactant which will result in the in-situ surfacant system having a salinity about equal to a salinity which results in minimal interfacial tension between the oil in the reservoir and the in-situ surfactant system at reservoir temperature, wherein the amount of the preformed cosurfactant is about 0.3 percent by weight in the aqueous alkaline solution; and injecting the cosurfactant-aqueous alkaline solution mixture into the reservoir to displace oil toward a fluid production location.

  20. The ribosome filter redux.

    PubMed

    Mauro, Vincent P; Edelman, Gerald M

    2007-09-15

    The ribosome filter hypothesis postulates that ribosomes are not simply translation machines but also function as regulatory elements that differentially affect or filter the translation of particular mRNAs. On the basis of new information, we take the opportunity here to review the ribosome filter hypothesis, suggest specific mechanisms of action, and discuss recent examples from the literature that support it. PMID:17890902

  1. Filter service system

    DOEpatents

    Sellers, Cheryl L.; Nordyke, Daniel S.; Crandell, Richard A.; Tomlins, Gregory; Fei, Dong; Panov, Alexander; Lane, William H.; Habeger, Craig F.

    2008-12-09

    According to an exemplary embodiment of the present disclosure, a system for removing matter from a filtering device includes a gas pressurization assembly. An element of the assembly is removably attachable to a first orifice of the filtering device. The system also includes a vacuum source fluidly connected to a second orifice of the filtering device.

  2. HEPA filter encapsulation

    DOEpatents

    Gates-Anderson, Dianne D.; Kidd, Scott D.; Bowers, John S.; Attebery, Ronald W.

    2003-01-01

    A low viscosity resin is delivered into a spent HEPA filter or other waste. The resin is introduced into the filter or other waste using a vacuum to assist in the mass transfer of the resin through the filter media or other waste.

  3. Nonlinear Attitude Filtering Methods

    NASA Technical Reports Server (NTRS)

    Markley, F. Landis; Crassidis, John L.; Cheng, Yang

    2005-01-01

    This paper provides a survey of modern nonlinear filtering methods for attitude estimation. Early applications relied mostly on the extended Kalman filter for attitude estimation. Since these applications, several new approaches have been developed that have proven to be superior to the extended Kalman filter. Several of these approaches maintain the basic structure of the extended Kalman filter, but employ various modifications in order to provide better convergence or improve other performance characteristics. Examples of such approaches include: filter QUEST, extended QUEST, the super-iterated extended Kalman filter, the interlaced extended Kalman filter, and the second-order Kalman filter. Filters that propagate and update a discrete set of sigma points rather than using linearized equations for the mean and covariance are also reviewed. A two-step approach is discussed with a first-step state that linearizes the measurement model and an iterative second step to recover the desired attitude states. These approaches are all based on the Gaussian assumption that the probability density function is adequately specified by its mean and covariance. Other approaches that do not require this assumption are reviewed, including particle filters and a Bayesian filter based on a non-Gaussian, finite-parameter probability density function on SO(3). Finally, the predictive filter, nonlinear observers and adaptive approaches are shown. The strengths and weaknesses of the various approaches are discussed.

  4. Practical Active Capacitor Filter

    NASA Technical Reports Server (NTRS)

    Shuler, Robert L., Jr. (Inventor)

    2005-01-01

    A method and apparatus is described that filters an electrical signal. The filtering uses a capacitor multiplier circuit where the capacitor multiplier circuit uses at least one amplifier circuit and at least one capacitor. A filtered electrical signal results from a direct connection from an output of the at least one amplifier circuit.

  5. 21 CFR 864.7660 - Leukocyte alkaline phosphatase test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Leukocyte alkaline phosphatase test. 864.7660... Leukocyte alkaline phosphatase test. (a) Identification. A leukocyte alkaline phosphatase test is a device used to identify the enzyme leukocyte alkaline phosphatase in neutrophilic granulocytes...

  6. 21 CFR 864.7660 - Leukocyte alkaline phosphatase test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Leukocyte alkaline phosphatase test. 864.7660... Leukocyte alkaline phosphatase test. (a) Identification. A leukocyte alkaline phosphatase test is a device used to identify the enzyme leukocyte alkaline phosphatase in neutrophilic granulocytes...

  7. Regenerative particulate filter development

    NASA Technical Reports Server (NTRS)

    Descamp, V. A.; Boex, M. W.; Hussey, M. W.; Larson, T. P.

    1972-01-01

    Development, design, and fabrication of a prototype filter regeneration unit for regenerating clean fluid particle filter elements by using a backflush/jet impingement technique are reported. Development tests were also conducted on a vortex particle separator designed for use in zero gravity environment. A maintainable filter was designed, fabricated and tested that allows filter element replacement without any leakage or spillage of system fluid. Also described are spacecraft fluid system design and filter maintenance techniques with respect to inflight maintenance for the space shuttle and space station.

  8. A bioengineered drug-Eluting scaffold accelerated cutaneous wound healing In diabetic mice.

    PubMed

    Yin, Hao; Ding, Guoshan; Shi, Xiaoming; Guo, Wenyuan; Ni, Zhijia; Fu, Hong; Fu, Zhiren

    2016-09-01

    Hyperglycemia in diabetic patients can greatly hinder the wound healing process. In this study we investigated if the engagement of F4/80(+) murine macrophages could accelerate the cutaneous wound healing in streptozotocin induced diabetic mice. To facilitate the engagement of macrophages, we engineered a drug-eluting electrospun scaffold with a payload of monocyte chemoattractant protein-1 (MCP-1). MCP-1 could be readily released from the scaffold within 3 days. The electrospun scaffold showed no cytotoxic effects on human keratinocytes in vitro. Full-thickness excisional cutaneous wound was created in diabetic mice. The wound fully recovered within 10 days in mice treated with the drug-eluting scaffold. In contrast, the wound took 14 days to fully recover in control groups. The use of drug-eluting scaffold also improved the re-epithelialization. Furthermore, we observed a larger population of F4/80(+) macrophages in the wound bed of mice treated with drug-eluting scaffolds on day 3. This marked increase of macrophages in the wound bed could have contributed to the accelerated wound healing. Our study shed new light on an immuno-engineering solution for wound healing management in diabetic patients. PMID:27187186

  9. Gene Expression Pattern after Insertion of Dexamethasone-Eluting Electrode into the Guinea Pig Cochlea

    PubMed Central

    Mugridge, Kenneth; Oguchi, Tomohiro; Hashimoto, Shigenari; Suzuki, Nobuyoshi; Iwasaki, Satoshi; Jolly, Claude; Usami, Shin-ichi

    2014-01-01

    A cochlear implant is an indispensable apparatus for a profound hearing loss patient. But insertion of the electrode entails a great deal of stress to the cochlea, and may cause irreversible damage to hair cells and related nerve structure. Although damage prevention effects of dexamethasone have been reported, long-term administration is difficult. In this study, we used a dexamethasone-eluting electrode in the guinea pig cochlea, and compared the gene expression after 7 days insertion with that of a normal electrode and non-surgically treated control by microarray. 40 genes were up-regulated 2-fold or more in the normal electrode group compared to the non-surgically treated group. Most of the up-regulated genes were associated with immune response and inflammation. In the dexamethasone-eluting group, compared to the normal electrode group, 7 of the 40 genes were further up-regulated, while 12 of them were down-regulated and there was a tendency to return to the non-surgical condition. 9 genes were down-regulated 2-fold or less with normal electrode insertion, and 4 of the 9 tended to return to the non-surgical condition in the dexamethasone-eluting group. These genes are certainly involved in the maintenance of the physiological functions of the cochlea. Our results indicate that the dexamethasone-eluting electrode will have an effect on the normalization of homeostasis in the cochlea. PMID:25329543

  10. Fiscal year 1996 laboratory scale studies of cesium elution in tank 8D-1

    SciTech Connect

    Russell, R.L.; Patello, G.K.; Sills, J.A.

    1996-09-01

    This report details work performed as part of the West Valley Support Project (WVSP) by Pacific Northwest National Laboratory (PNNL). This work is intended to support residual waste removal during high-level waste (HLW) tank stabilization activities to be performed by the West valley Demonstration Project (WVDP). The HLW originated from a now inactive commercial nuclear fuel-reprocessing plant at West Valley, New York. It is stored in a carbon-steel tank designated 8D-2. Cesium-loaded zeolite was generated by a supernatant decontamination process involving ion exchange. The exchange columns and the spent zeolite are stored in a carbon-steel tank designated 8D-1. During the vitrification phase of the WVDP waste remediation, and estimated 95 percent of the zeolite will be transferred from tank 8D-1 to tank 8D- 2. The remaining cesium-loaded zeolite will require treatment to remove the highly radioactive cesium. This report summarizes the findings of laboratory experiments. The primary objectives of these experiments were: to refine the optimum process conditions for use of oxalic acid to elute cesium from zeolite; minimize iron dissolution during cesium elution; investigation of the effect of neutralization on cesium elution; determination of effects of zeolite particle size on cesium elution; and determine if aluminum can be used as an indicator for cesium in solution.

  11. Elution of zinc in dust discharged from electric arc furnace in carbonic acid solution

    NASA Astrophysics Data System (ADS)

    Yokoyama, S.; Sasaki, T.; Sasano, J.; Izaki, M.

    2012-03-01

    The dust discharged from an electric arc furnace (EAF) is a valuable resource of zinc. As a fundamental study of extraction of zinc, iron and chlorine in the EAF dust, the elution behavior of them in carbonic acid solution was studied. The influence of the weight of the EAF dust on the elution behavior was examined in this study. Experiment was carried out putting the EAF dust from 1 g to 200 g in weight into 1 L of water that was introduced by CO2. Generally, the pH in the aqueous solution increased with an increase in weight of the additive EAF dust. Maximums of the eluted concentrations of zinc and chloride ion increased with an increase in the weight of the additive EAF dust whereas the extraction ratios of both of them decreased with an increase in the weight of the additive EAF dust. Iron in the EAF dust remained in the dust without elution. The limit of extraction of zinc from the EAF dust to water was given by the solubilities of ZnFe2O4 and ZnO expressed by eq. (6) and eq. (9) respectively.

  12. A new mixed-mode model for interpreting and predicting protein elution during isoelectric chromatofocusing.

    PubMed

    Choy, Derek Y C; Creagh, A Louise; von Lieres, Eric; Haynes, Charles

    2014-05-01

    Experimental data are combined with classic theories describing electrolytes in solution and at surfaces to define the primary mechanisms influencing protein retention and elution during isoelectric chromatofocusing (ICF) of proteins and protein mixtures. Those fundamental findings are used to derive a new model to understand and predict elution times of proteins during ICF. The model uses a modified form of the steric mass action (SMA) isotherm to account for both ion exchange and isoelectric focusing contributions to protein partitioning. The dependence of partitioning on pH is accounted for through the characteristic charge parameter m of the SMA isotherm and the application of Gouy-Chapman theory to define the dependence of the equilibrium binding constant Kbi on both m and ionic strength. Finally, the effects of changes in matrix surface pH on protein retention are quantified through a Donnan equilibrium type model. By accounting for isoelectric focusing, ion binding and exchange, and surface pH contributions to protein retention and elution, the model is shown to accurately capture the dependence of protein elution times on column operating conditions. PMID:24293057

  13. Clopidogrel discontinuation within the first year after coronary drug-eluting stent implantation: an observational study

    PubMed Central

    2014-01-01

    Background The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. Methods We followed 4,154 patients treated with coronary drug-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e., cardiac death, myocardial infarction, or stent thrombosis) from medical databases. Results Discontinuation of clopidogrel within the first 3 months after stent implantation was associated with a significantly increased rate of MACE at 1-year follow-up (hazard ratio (HR) 2.06; 95% confidence interval (CI): 1.08-3.93). Discontinuation 3-6 months (HR 1.29; 95% CI: 0.70-2.41) and 6-12 months (HR 1.29; 95% CI: 0.54-3.07) after stent implantation were associated with smaller, not statistically significant, increases in MACE rates. Among patients who discontinued clopidogrel, MACE rates were highest within the first 2 months after discontinuation. Conclusions Discontinuation of clopidogrel was associated with an increased rate of MACE among patients treated with drug-eluting stents. The increase was statistically significant within the first 3 months after drug-eluting stent implantation but not after 3 to 12 months. PMID:25125079

  14. ADSORPTION OF ENTEROVIRUSES TO SOIL CORES AND THEIR SUBSEQUENT ELUTION BY ARTIFICIAL RAINWATER

    EPA Science Inventory

    The adsorption and elution of a variety of human enteroviruses in a highly permeable, sandy soil was studied by using cores (43 by 125 mm) collected from an operating recharge basin on Long Island. Viruses studied included field and reference strains of polioviruses types 1 and 3...

  15. Selection of the Optimum Electrospray Voltage for Gradient Elution LC-MS Measurements

    SciTech Connect

    Marginean, Ioan; Kelly, Ryan T.; Moore, Ronald J.; Prior, David C.; Lamarche, Brian L.; Tang, Keqi; Smith, Richard D.

    2009-04-01

    Changes in liquid composition during gradient elution liquid chromatography (LC) and mass spectrometry (MS) analyses affect the electrospray operation. To establish methodologies for judicious selection of the electrospray voltage, we monitored in real-time the effect of the LC gradient on the spray current. The optimum range of the electrospray voltage shifted to lower values as the concentration of organic solvent in the eluent increased during reversed-phase LC analyses. These results provided the means to rationally select the voltage that ensured successful electrospray operation throughout gradient elution LC-MS experiments. A small run-to-run drift in the spray current was observed for electrosprays operated at constant voltage. This could be the result of fouling or degradation of the electrospray emitter, which affected the electric field driving the electrospray. Algorithms using feedback from spray current measurements to maintain the electrospray voltage within the optimum operating range throughout gradient elution LC-MS were evaluated. The electrospray operation with voltage regulation and at constant, judiciously selected voltage during gradient elution LC-MS measurements produced data with similar reproducibility.

  16. Elution-Extrusion Countercurrent Chromatography: Theory and Concepts in Metabolic Analysis

    PubMed Central

    Berthod, Alain; Friesen, J. Brent; Inui, Taichi; Pauli, Guido F.

    2008-01-01

    Elution-extrusion countercurrent chromatography (EECCC) takes full advantage of the liquid nature of the stationary phase in CCC by combining regular chromatographic elution with stationary phase extrusion. EECCC is shown to be a three-stage process consisting of classical elution (I), sweeping elution (II), and extrusion (III). After only two column volumes of solvent, it rapidly yields a high-resolution chromatogram that covers an extended polarity range of solutes. As hydrophilicity/lipophilicity balance is a crucial discriminatory property of analytes in highly complex mixtures such as metabolomic samples, the precise determination of CCC distribution constants (KD) is vital to the analysis of metabolomes and other complex biological matrices. This work builds the EECCC concept by performing a full theoretical treatment and providing equations for retention volumes, peak widths, resolution factors, and distribution constants. Experimental validation utilizes natural products standards that resemble the zero to infinity range of the polarity continuum. EECCC extends the “sweet spot” of high-resolution in CCC, and provides access to the otherwise practically unapproachable high-KD portion of the high-resolution chromatograms in CCC. Its improved capabilities of KD-targeting make EECCC a promising tool for the specific analysis of “small” molecules in complex samples such as in metabolomic fingerprinting and footprinting. PMID:17408244

  17. The utility of accurate mass and LC elution time information in the analysis of complex proteomes

    SciTech Connect

    Norbeck, Angela D.; Monroe, Matthew E.; Adkins, Joshua N.; Anderson, Kevin K.; Daly, Don S.; Smith, Richard D.

    2005-08-01

    Theoretical tryptic digests of all predicted proteins from the genomes of three organisms of varying complexity were evaluated for specificity and possible utility of combined peptide accurate mass and predicted LC normalized elution time (NET) information. The uniqueness of each peptide was evaluated using its combined mass (+/- 5 ppm and 1 ppm) and NET value (no constraint, +/- 0.05 and 0.01 on a 0-1 NET scale). The set of peptides both underestimates actual biological complexity due to the lack of specific modifications, and overestimates the expected complexity since many proteins will not be present in the sample or observable on the mass spectrometer because of dynamic range limitations. Once a peptide is identified from an LCMS/MS experiment, its mass and elution time is representative of a unique fingerprint for that peptide. The uniqueness of that fingerprint in comparison to that for the other peptides present is indicative of the ability to confidently identify that peptide based on accurate mass and NET measurements. These measurements can be made using HPLC coupled with high resolution MS in a high-throughput manner. Results show that for organisms with comparatively small proteomes, such as Deinococcus radiodurans, modest mass and elution time accuracies are generally adequate for peptide identifications. For more complex proteomes, increasingly accurate easurements are required. However, the majority of proteins should be uniquely identifiable by using LC-MS with mass accuracies within +/- 1 ppm and elution time easurements within +/- 0.01 NET.

  18. A comparison of two methods of eluting insect DNA from Flinders Technology Associates Cards

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Flinders Technology Associates (FTA) technology lyses cells and stabilizes DNA for room-temperature storage in a single step but it has been infrequently used with arthropods. One possible reason is the paucity of quick and inexpensive protocols to subsequently elute the DNA from the card matrix. Th...

  19. Very late sirolimus-eluting stent displaced fracture in the mid-left anterior descending artery.

    PubMed

    Rahman, Nasir; Dhakam, Sajid; Kazmi, Khawar Abbass

    2008-06-01

    Coronary stent fractures are very rare. The predisposing factors for stent fractures are excessive postdilatation, overlapping stents and a hinge site in a tortuous coronary artery. We report a case of very late (after 699 days), displaced, sirolimus-eluting stent fracture deployed at nominal pressures without postdilatation and at a non-hinge portion of the left anterior descending artery. PMID:18523336

  20. 40 CFR 799.6784 - TSCA water solubility: Column elution method; shake flask method.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false TSCA water solubility: Column elution... AND MIXTURE TESTING REQUIREMENTS Product Properties Test Guidelines § 799.6784 TSCA water solubility... here may not yet be optimal. This method is intended for material with solubilities below...

  1. 40 CFR 799.6784 - TSCA water solubility: Column elution method; shake flask method.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 32 2014-07-01 2014-07-01 false TSCA water solubility: Column elution... AND MIXTURE TESTING REQUIREMENTS Product Properties Test Guidelines § 799.6784 TSCA water solubility... here may not yet be optimal. This method is intended for material with solubilities below...

  2. 40 CFR 799.6784 - TSCA water solubility: Column elution method; shake flask method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 33 2012-07-01 2012-07-01 false TSCA water solubility: Column elution... AND MIXTURE TESTING REQUIREMENTS Product Properties Test Guidelines § 799.6784 TSCA water solubility... here may not yet be optimal. This method is intended for material with solubilities below...

  3. Elution profiles of lanthanides with α-hydroxyisobutyric acid by ion exchange chromatography using fine resin.

    PubMed

    Trikha, Rahul; Sharma, Bal Krishan; Sabharwal, Kanwal Nain; Prabhu, Krishan

    2015-11-01

    Experiments were carried out using a strong acid cation exchange resin with a particle size of 75-150 μm, termed as "fine resin" in hydrogen ion form for the elution of individual lanthanides Sm, Eu, Gd, Tb, and Dy that are produced as fission products in the spent nuclear fuel and generated in the effluent during reprocessing of spent nuclear fuel. Batch experiments were carried out to study the effect of concentration of nitric acid on distribution coefficient. The distribution coefficient values for these individual lanthanides were determined in nitric acid medium in the concentration range of 0.01-4.0 N. Uptake of each individual lanthanide by resin was increased with increased nitric acid concentration from 0.01 to 0.5 N and remained similar from 0.5 to 1.0 N and decreased thereafter up to 4.0 N. Column experiments were also carried out using the same resin to study the parameters like pH of the eluent, flow rate, and resin bed height under isocratic elution conditions for eluting lanthanide elements using α-hydroxyisobutyric acid as eluent. The results of this study have indicated the possibility for the elution of individual lanthanides. PMID:26333182

  4. Multiple biological complex of alkaline extract of the leaves of Sasa senanensis Rehder.

    PubMed

    Sakagami, Hiroshi; Zhou, Li; Kawano, Michiyo; Thet, May Maw; Tanaka, Shoji; Machino, Mamoru; Amano, Shigeru; Kuroshita, Reina; Watanabe, Shigeru; Chu, Qing; Wang, Qin-Tao; Kanamoto, Taisei; Terakubo, Shigemi; Nakashima, Hideki; Sekine, Keisuke; Shirataki, Yoshiaki; Zhang, Chang-Hao; Uesawa, Yoshihiro; Mohri, Kiminori; Kitajima, Madoka; Oizumi, Hiroshi; Oizumi, Takaaki

    2010-01-01

    Previous studies have shown anti-inflammatory potential of alkaline extract of the leaves of Sasa senanensis Rehder (SE). The aim of the present study was to clarity the molecular entity of SE, using various fractionation methods. SE inhibited the production of nitric oxide (NO), but not tumour necrosis factor-α by lipopolysaccharide (LPS)-stimulated mouse macrophage-like cells. Lignin carbohydrate complex prepared from SE inhibited the NO production to a comparable extent with SE, whereas chlorophyllin was more active. On successive extraction with organic solvents, nearly 90% of SE components, including chlorophyllin, were recovered from the aqueous layer. Anti-HIV activity of SE was comparable with that of lignin-carbohydrate complex, and much higher than that of chlorophyllin and n-butanol extract fractions. The CYP3A inhibitory activity of SE was significantly lower than that of grapefruit juice and chlorophyllin. Oral administration of SE slightly reduced the number of oral bacteria. When SE was applied to HPLC, nearly 70% of SE components were eluted as a single peak. These data suggest that multiple components of SE may be associated with each other in the native state or after extraction with alkaline solution. PMID:20952742

  5. Ceramic fiber filter technology

    SciTech Connect

    Holmes, B.L.; Janney, M.A.

    1996-06-01

    Fibrous filters have been used for centuries to protect individuals from dust, disease, smoke, and other gases or particulates. In the 1970s and 1980s ceramic filters were developed for filtration of hot exhaust gases from diesel engines. Tubular, or candle, filters have been made to remove particles from gases in pressurized fluidized-bed combustion and gasification-combined-cycle power plants. Very efficient filtration is necessary in power plants to protect the turbine blades. The limited lifespan of ceramic candle filters has been a major obstacle in their development. The present work is focused on forming fibrous ceramic filters using a papermaking technique. These filters are highly porous and therefore very lightweight. The papermaking process consists of filtering a slurry of ceramic fibers through a steel screen to form paper. Papermaking and the selection of materials will be discussed, as well as preliminary results describing the geometry of papers and relative strengths.

  6. Compact planar microwave blocking filters

    NASA Technical Reports Server (NTRS)

    U-Yen, Kongpop (Inventor); Wollack, Edward J. (Inventor)

    2012-01-01

    A compact planar microwave blocking filter includes a dielectric substrate and a plurality of filter unit elements disposed on the substrate. The filter unit elements are interconnected in a symmetrical series cascade with filter unit elements being organized in the series based on physical size. In the filter, a first filter unit element of the plurality of filter unit elements includes a low impedance open-ended line configured to reduce the shunt capacitance of the filter.

  7. Small-Column Cesium Ion Exchange Elution Testing of Spherical Resorcinol-Formaldehyde

    SciTech Connect

    Brown, Garrett N.; Russell, Renee L.; Peterson, Reid A.

    2011-10-21

    This report summarizes the work performed to evaluate multiple, cesium loading, and elution cycles for small columns containing SRF resin using a simple, high-level waste (HLW) simulant. Cesium ion exchange loading and elution curves were generated for a nominal 5 M Na, 2.4E-05 M Cs, 0.115 M Al loading solution traced with 134Cs followed by elution with variable HNO3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with 137Cs. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small ({approx}15.7 mL) bed of SRF resin with a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45 C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with 29+ BVs of HNO3 processed at 25 C and at 1.4 BV/h. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium leakage) to help establish acid strength and purity requirements.

  8. Switching types of drug-eluting stents does not prevent repeated in-stent restenosis in patients with coronary drug-eluting stent restenosis

    PubMed Central

    Yasuoka, Yoshinori; Kume, Kiyoshi; Adachi, Hidenori; Hattori, Susumu; Matsutera, Ryo; Kohama, Yasuaki; Sasaki, Tatsuya

    2014-01-01

    Objectives We treated patients experiencing drug-eluting stent (DES) restenosis with plain old balloon angioplasty (POBA), implantation of the same type of DES [homogeneous drug-eluting stent (HOMO-DES)], or implantation of a different type of DES [heterogeneous drug-eluting stent (HETERO-DES)], and compared the efficacy and safety of these procedures for the prevention of repeated in-stent restenosis (ISR). Background In patients with de-novo coronary lesions, DES implantation is associated with a markedly reduced restenosis rate as compared with that associated with a bare metal stent and POBA. However, the optimal management strategy for patients with DES ISR remains unknown. Patients and methods We identified 191 consecutive DES ISR lesions from 183 patients who required clinically driven revascularization and divided them into three groups according to the treatment: 38 lesions were treated with POBA, 38 with HOMO-DES, and 115 with HETERO-DES. Results The incidence of target lesion revascularization (TLR) was 42.1% (16/38), 15.8% (6/38), and 16.5% (19/115) in the POBA, HOMO-DES, and HETERO-DES groups (POBA vs. HOMO, HETERO-DES; P=0.002, respectively). Multivariate analysis indicated that diabetes [odds ratio (OR), 3.4], hemodialysis (OR, 7.74), nonfocal ISR patterns (OR, 3.35), previous myocardial infarction (OR, 3.26), and POBA (OR, 8.84) were independent predictors of TLR. Conclusion A strategy involving repeated DES implantation was superior to POBA for preventing recurrent restenosis. Treatment with a different type or generation of DES does not appear to reduce the incidence of TLR. Moreover, we identified certain useful factors for facilitating appropriate and early triage in the patients with repeated DES ISR. PMID:25076360

  9. Fabric filter blinding mechanisms

    SciTech Connect

    Notestein, J.E.; Shang, J.Y.

    1982-08-01

    This discussion of various bag/cloth filter degradation mechanisms is mostly common sense. However, this information is occasionally lost in the subtleties of real-system operation. Although this paper is written with reference to fluidized-bed combustion (FBC) applications, the insights are generally applicable. For enumeration of particular filter fabric and baghouse experiences in FBC applications, the reader is referred to a report by Davy McKee Corporatin (no date). A fabric filter is a composite matrix of fibers oriented to retain the dust particles from dust-laden gas. The cleaned gas passes through the fabric filter; the retained dust particles are deposited on the surface of (and within) the fiber matrix. The retained dust can be later removed through mechanical means. The fabric may be made of any fibrous material, spun in yarn, and then woven, impacted, needled, or bonded into a felt. Deep penetration of aggregated fine particles, lack of dust removal during filter cleaning, and chars or condensed aerosols may contribute to the increase in pressure drop across the filter. This increases the filter operation power consumption and, consequently, reduces the filtration capacity. The phenomenon of building a high-pressure drop in spite of filter cleaning provisions is known as blinding. In order to maintain an acceptable gas throughput, blinding problems must be addressed. Recommendations are given: maintain temperature above dew point, use filter aids, by-pass filter during start-up or operational upsets, etc.

  10. Filtering separators having filter cleaning apparatus

    SciTech Connect

    Margraf, A.

    1984-08-28

    This invention relates to filtering separators of the kind having a housing which is subdivided by a partition, provided with parallel rows of holes or slots, into a dust-laden gas space for receiving filter elements positioned in parallel rows and being impinged upon by dust-laden gas from the outside towards the inside, and a clean gas space. In addition, the housing is provided with a chamber for cleansing the filter element surfaces of a row by counterflow action while covering at the same time the partition holes or slots leading to the adjacent rows of filter elements. The chamber is arranged for the supply of compressed air to at least one injector arranged to feed compressed air and secondary air to the row of filter elements to be cleansed. The chamber is also reciprocatingly displaceable along the partition in periodic and intermittent manner. According to the invention, a surface of the chamber facing towards the partition covers at least two of the rows of holes or slots of the partition, and the chamber is closed upon itself with respect to the clean gas space, and is connected to a compressed air reservoir via a distributor pipe and a control valve. At least one of the rows of holes or slots of the partition and the respective row of filter elements in flow communication therewith are in flow communication with the discharge side of at least one injector acted upon with compressed air. At least one other row of the rows of holes or slots of the partition and the respective row of filter elements is in flow communication with the suction side of the injector.

  11. Generic Kalman Filter Software

    NASA Technical Reports Server (NTRS)

    Lisano, Michael E., II; Crues, Edwin Z.

    2005-01-01

    The Generic Kalman Filter (GKF) software provides a standard basis for the development of application-specific Kalman-filter programs. Historically, Kalman filters have been implemented by customized programs that must be written, coded, and debugged anew for each unique application, then tested and tuned with simulated or actual measurement data. Total development times for typical Kalman-filter application programs have ranged from months to weeks. The GKF software can simplify the development process and reduce the development time by eliminating the need to re-create the fundamental implementation of the Kalman filter for each new application. The GKF software is written in the ANSI C programming language. It contains a generic Kalman-filter-development directory that, in turn, contains a code for a generic Kalman filter function; more specifically, it contains a generically designed and generically coded implementation of linear, linearized, and extended Kalman filtering algorithms, including algorithms for state- and covariance-update and -propagation functions. The mathematical theory that underlies the algorithms is well known and has been reported extensively in the open technical literature. Also contained in the directory are a header file that defines generic Kalman-filter data structures and prototype functions and template versions of application-specific subfunction and calling navigation/estimation routine code and headers. Once the user has provided a calling routine and the required application-specific subfunctions, the application-specific Kalman-filter software can be compiled and executed immediately. During execution, the generic Kalman-filter function is called from a higher-level navigation or estimation routine that preprocesses measurement data and post-processes output data. The generic Kalman-filter function uses the aforementioned data structures and five implementation- specific subfunctions, which have been developed by the user on

  12. Intermediate range order in alkaline borate glasses

    NASA Astrophysics Data System (ADS)

    Crupi, C.; Carini, G.; Ruello, G.; D'Angelo, G.

    2016-03-01

    We describe the neutron diffraction patterns of a series of alkaline borate glasses at different metal oxide content. Strong differences are observed in the intermediate range order as a function of the specific alkaline ion and of its concentration. On these results, we propose that the first sharp diffraction peak arises from correlations of atoms of voids and show that the compositional variation of this peak intensity in alkaline borate glasses is due to changes in the distribution of void sizes within the three-dimensional network. We argue that our interpretation in terms of interstitial (empty and/or filled) voids, having different sizes, provides a general explanation for all anomalous behaviours revealed for the first sharp diffraction peak.

  13. Concentric Split Flow Filter

    NASA Technical Reports Server (NTRS)

    Stapleton, Thomas J. (Inventor)

    2015-01-01

    A concentric split flow filter may be configured to remove odor and/or bacteria from pumped air used to collect urine and fecal waste products. For instance, filter may be designed to effectively fill the volume that was previously considered wasted surrounding the transport tube of a waste management system. The concentric split flow filter may be configured to split the air flow, with substantially half of the air flow to be treated traveling through a first bed of filter media and substantially the other half of the air flow to be treated traveling through the second bed of filter media. This split flow design reduces the air velocity by 50%. In this way, the pressure drop of filter may be reduced by as much as a factor of 4 as compare to the conventional design.

  14. Optically tunable optical filter

    NASA Astrophysics Data System (ADS)

    James, Robert T. B.; Wah, Christopher; Iizuka, Keigo; Shimotahira, Hiroshi

    1995-12-01

    We experimentally demonstrate an optically tunable optical filter that uses photorefractive barium titanate. With our filter we implement a spectrum analyzer at 632.8 nm with a resolution of 1.2 nm. We simulate a wavelength-division multiplexing system by separating two semiconductor laser diodes, at 1560 nm and 1578 nm, with the same filter. The filter has a bandwidth of 6.9 nm. We also use the same filter to take 2.5-nm-wide slices out of a 20-nm-wide superluminescent diode centered at 840 nm. As a result, we experimentally demonstrate a phenomenal tuning range from 632.8 to 1578 nm with a single filtering device.

  15. Contactor/filter improvements

    DOEpatents

    Stelman, D.

    1988-06-30

    A contactor/filter arrangement for removing particulate contaminants from a gaseous stream is described. The filter includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. A cover screen isolates the filter element from contact with the moving granular bed. In one embodiment, the granular material is comprised of porous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses. 6 figs.

  16. Alkaline Band Formation in Chara corallina

    PubMed Central

    Lucas, William J.

    1979-01-01

    The nature of the transport system responsible for the establishment of alkaline bands on cells of Chara corallina was investigated. The transport process was found to be insensitive to external pH, provided the value was above a certain threshold. At this threshold (pH 5.1 to 4.8) the transport process was inactivated. Transport function could be recovered by raising the pH value of the external solution. The fastest rate of recovery was always obtained in the presence of exogenous HCO3−. Experiments in which plasmalemma integrity was modified using 10 millimolar K+ treatment were also performed. Alkaline band transport was significantly reduced in the presence of 10 millimolar K+, but the system did not recover, following return to 0.2 millimolar K+ solutions, until the transport site was reexposed to exogenous HCO3−. The influence of presence and absence of various cations on both alkaline band transport and total H14CO3− assimilation was examined. No specific cation requirement (mono- or divalent) was found for either process, except the previously established role of Ca2+ at the HCO3− transport site. The alkaline band transport process exhibited a general requirement for cations. This transport system could be partially or completely stalled in low cation solutions, or glass-distilled water, respectively. The results indicate that no cationic flux occurs across the plasmalemma in direct association with either the alkaline band or HCO3− transport systems. It is felt that the present results offer support for the hypothesis that an OH− efflux transport system (rather than a H+ influx system) is responsible for alkaline band development in C. corallina. The results support the hypothesis that OH− efflux is an electrogenic process. This OH− transport system also appears to contain two allosteric effector sites, involving an acidic group and a HCO3− ion. PMID:16660706

  17. Hybrid Filter Membrane

    NASA Technical Reports Server (NTRS)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  18. Filter vapor trap

    DOEpatents

    Guon, Jerold

    1976-04-13

    A sintered filter trap is adapted for insertion in a gas stream of sodium vapor to condense and deposit sodium thereon. The filter is heated and operated above the melting temperature of sodium, resulting in a more efficient means to remove sodium particulates from the effluent inert gas emanating from the surface of a liquid sodium pool. Preferably the filter leaves are precoated with a natrophobic coating such as tetracosane.

  19. Degradation of halogenated carbons in alkaline alcohol

    NASA Astrophysics Data System (ADS)

    Nakagawa, Seiko; Shimokawa, Toshinari

    2002-02-01

    1,1,2-Trichloro-trifluoroethane, 1,2-dibromo-tetrafluoroethane, 2,3,4,6-tetrachlorophenol, 1,2,4-trichlorobenzene, and 2,4,6-trichloroanisole were dissolved in alkaline isopropyl alcohol and irradiated with 60Co gamma rays after purged with pure nitrogen gas. The concentration of the hydroxide ions and the parent molecules decreased with the dose, while that of the halide ions and the organic products, with less halogen atoms than the parent, increased. Chain degradation will occur in alkaline isopropyl alcohol.

  20. Alkaline earth filled nickel skutterudite antimonide thermoelectrics

    DOEpatents

    Singh, David Joseph

    2013-07-16

    A thermoelectric material including a body centered cubic filled skutterudite having the formula A.sub.xFe.sub.yNi.sub.zSb.sub.12, where A is an alkaline earth element, x is no more than approximately 1.0, and the sum of y and z is approximately equal to 4.0. The alkaline earth element includes guest atoms selected from the group consisting of Be, Mb, Ca, Sr, Ba, Ra and combinations thereof. The filled skutterudite is shown to have properties suitable for a wide variety of thermoelectric applications.

  1. Laser direct write of planar alkaline microbatteries

    NASA Astrophysics Data System (ADS)

    Arnold, C. B.; Kim, H.; Piqué, A.

    We are developing a laser engineering approach to fabricate and optimize alkaline microbatteries in planar geometries. The laser direct-write technique enables multicapability for adding, removing and processing material and provides the ability to pattern complicated structures needed for fabricating complete microbattery assemblies. In this paper, we demonstrate the production of planar zinc-silver oxide alkaline cells under ambient conditions. The microbattery cells exhibit 1.55-V open-circuit potentials, as expected for the battery chemistry, and show a flat discharge behavior under constant-current loads. High capacities of over 450 μAhcm-2 are obtained for 5-mm2 microbatteries.

  2. Alkaline Capacitors Based on Nitride Nanoparticles

    NASA Technical Reports Server (NTRS)

    Aldissi, Matt

    2003-01-01

    High-energy-density alkaline electrochemical capacitors based on electrodes made of transition-metal nitride nanoparticles are undergoing development. Transition- metal nitrides (in particular, Fe3N and TiN) offer a desirable combination of high electrical conductivity and electrochemical stability in aqueous alkaline electrolytes like KOH. The high energy densities of these capacitors are attributable mainly to their high capacitance densities, which, in turn, are attributable mainly to the large specific surface areas of the electrode nanoparticles. Capacitors of this type could be useful as energy-storage components in such diverse equipment as digital communication systems, implanted medical devices, computers, portable consumer electronic devices, and electric vehicles.

  3. Westinghouse filter update

    SciTech Connect

    Bruck, G.J.; Smeltzer, E.E.; Newby, R.A.; Bachovchin, D.M.

    1993-06-01

    The Department of Energy, Morgantown Energy Technology Center (DOE/METC), with Westinghouse are developing high temperature particulate filters for application in integrated, coal gasification combined cycle (IGCC) and pressurized fluidized bed combustion (PFBC) power generation systems. Development of these IGCC and PFBC advanced power cycles using subpilot and pilot scale facilities include the integrated operation of a high temperature particulate filter. This testing provides the basis for evaluating filter design, performance and operation characteristics in the actual process gas environment. This operating data is essential for the specification of components and materials and successful scaleup of the filter systems for demonstration and commercial application.

  4. Independent task Fourier filters

    NASA Astrophysics Data System (ADS)

    Caulfield, H. John

    2001-11-01

    Since the early 1960s, a major part of optical computing systems has been Fourier pattern recognition, which takes advantage of high speed filter changes to enable powerful nonlinear discrimination in `real time.' Because filter has a task quite independent of the tasks of the other filters, they can be applied and evaluated in parallel or, in a simple approach I describe, in sequence very rapidly. Thus I use the name ITFF (independent task Fourier filter). These filters can also break very complex discrimination tasks into easily handled parts, so the wonderful space invariance properties of Fourier filtering need not be sacrificed to achieve high discrimination and good generalizability even for ultracomplex discrimination problems. The training procedure proceeds sequentially, as the task for a given filter is defined a posteriori by declaring it to be the discrimination of particular members of set A from all members of set B with sufficient margin. That is, we set the threshold to achieve the desired margin and note the A members discriminated by that threshold. Discriminating those A members from all members of B becomes the task of that filter. Those A members are then removed from the set A, so no other filter will be asked to perform that already accomplished task.

  5. Filter construction and design.

    PubMed

    Jornitz, Maik W

    2006-01-01

    Sterilizing and pre-filters are manufactured in different formats and designs. The criteria for the specific designs are set by the application and the specifications of the filter user. The optimal filter unit or even system requires evaluation, such as flow rate, throughput, unspecific adsorption, steam sterilizability and chemical compatibility. These parameters are commonly tested within a qualification phase, which ensures that an optimal filter design and combination finds its use. If such design investigations are neglected it could be costly in the process scale. PMID:16570863

  6. Nanofiber Filters Eliminate Contaminants

    NASA Technical Reports Server (NTRS)

    2009-01-01

    With support from Phase I and II SBIR funding from Johnson Space Center, Argonide Corporation of Sanford, Florida tested and developed its proprietary nanofiber water filter media. Capable of removing more than 99.99 percent of dangerous particles like bacteria, viruses, and parasites, the media was incorporated into the company's commercial NanoCeram water filter, an inductee into the Space Foundation's Space Technology Hall of Fame. In addition to its drinking water filters, Argonide now produces large-scale nanofiber filters used as part of the reverse osmosis process for industrial water purification.

  7. Linear phase compressive filter

    DOEpatents

    McEwan, T.E.

    1995-06-06

    A phase linear filter for soliton suppression is in the form of a laddered series of stages of non-commensurate low pass filters with each low pass filter having a series coupled inductance (L) and a reverse biased, voltage dependent varactor diode, to ground which acts as a variable capacitance (C). L and C values are set to levels which correspond to a linear or conventional phase linear filter. Inductance is mapped directly from that of an equivalent nonlinear transmission line and capacitance is mapped from the linear case using a large signal equivalent of a nonlinear transmission line. 2 figs.

  8. Linear phase compressive filter

    DOEpatents

    McEwan, Thomas E.

    1995-01-01

    A phase linear filter for soliton suppression is in the form of a laddered series of stages of non-commensurate low pass filters with each low pass filter having a series coupled inductance (L) and a reverse biased, voltage dependent varactor diode, to ground which acts as a variable capacitance (C). L and C values are set to levels which correspond to a linear or conventional phase linear filter. Inductance is mapped directly from that of an equivalent nonlinear transmission line and capacitance is mapped from the linear case using a large signal equivalent of a nonlinear transmission line.

  9. Comparison of a drug-eluting balloon first and then bare metal stent with a drug-eluting stent for treatment of de novo lesions: study protocol of a randomized controlled trial

    PubMed Central

    2013-01-01

    Background The use of a drug-eluting balloon for the treatment of de novo coronary artery lesions remains to be evaluated. A previous trial in patients with stable and unstable angina comparing a bare metal stent mounted on a drug-eluting balloon with a sirolimus-eluting stent failed to meet the prespecified non-inferiority criteria versus the sirolimus-eluting stent. The stent struts of a bare metal stent pre-mounted on a drug-eluting balloon may prevent the appropriate delivery of drugs to the vessel wall and may result in reduced efficacy. In the present study we will therefore evaluate the efficacy of a drug-eluting balloon for treating de novo coronary artery lesions using a strategy designed to uniformly deliver drug to the vessel with a bare metal stent. Methods/Design The Comparison of Drug-Eluting Balloon first study is a prospective, randomized, open-label trial designed to demonstrate the non-inferiority of first using a drug-eluting balloon (Sequent® please; B. Braun, Melsungen, Germany) followed by a bare metal stent (Coroflex® Blue; B. Braun) compared with using a drug-eluting stent (Resolute Integrity™; Boston Scientific, Natick, MA, USA) for de novo coronary artery lesions. The primary endpoint of the study is in-segment late loss at 9 months measured by quantitative coronary angiography. Secondary endpoints include angiographic findings such as angiographic success, device success, binary angiographic restenosis, and clinical outcomes such as procedural success, all-cause death, myocardial infarction, target vessel revascularization, target lesion revascularization, and stent thrombosis. A total of 180 patients will be enrolled in the study. Discussion The Comparison of Drug-Eluting Balloon first study will evaluate the clinical efficacy, angiographic outcomes and safety of a drug-eluting balloon first followed by a bare metal stent compared with a drug-eluting stent for the treatment of de novo coronary artery lesions. Trial registration

  10. Influence of Sterilization and Storage Period on Elution of Polyvinylpyrrolidone from Wet-Type Polysulfone Membrane Dialyzers.

    PubMed

    Miyata, Masahiro; Konishi, Shuji; Shimamoto, Yoshimasa; Kamada, Aki; Umimoto, Koichi

    2015-01-01

    The objectives of this study were to investigate the influence of the sterilization and storage period on elution of polyvinylpyrrolidone (PVP) from wet-type polysulfone (PSu) membrane dialyzers. APS-15SA (APS) dialyzers sterilized by gamma-radiation and RENAK PS-1.6 (RENAK) dialyzers sterilized by autoclaving were compared in this study. Each dialyzer was washed with physiological saline and the amount of PVP eluted from the PSu membrane was measured. Then, experimental use of each dialyzer was performed by circulating physiological saline for 4 hours, after which the PVP eluted from the PSu membrane was measured. As the results, the amount of PVP eluted by washing was positively correlated with the storage period for both dialyzers (APS: rs = 0.958; RENAK: rs = 0.952). In the experimental circuit, the amount of PVP eluted from the RENAK dialyzer was positively correlated with the storage period (rs = 0.810), whereas the amount of PVP eluted from the APS dialyzer was negatively correlated with the storage period (rs = -0.833). We found that the amount of PVP eluted from PSu membrane is quite different by the sterilization and storage period of dialyzers. PMID:25851313

  11. Uneven-order decentered Shapiro filters for boundary filtering

    NASA Astrophysics Data System (ADS)

    Falissard, F.

    2015-07-01

    This paper addresses the use of Shapiro filters for boundary filtering. A new class of uneven-order decentered Shapiro filters is proposed and compared to classical Shapiro filters and even-order decentered Shapiro filters. The theoretical analysis shows that the proposed boundary filters are more accurate than the centered Shapiro filters and more robust than the even-order decentered boundary filters usable at the same distance to the boundary. The benefit of the new boundary filters is assessed for computations using the compressible Euler equations.

  12. Comparative Study of Four Microporous Filters for Concentrating Viruses from Drinking Water

    PubMed Central

    Jakubowski, Walter; Hill, William F.; Clarke, Norman A.

    1975-01-01

    Four microporous virus-adsorbent filter media for recovering low levels of virus from 380 liters of drinking water were compared. In addition, two of the filter media were compared with 1,900 liters of drinking water. The filter media evaluated were MF nitrocellulose membranes (293 mm), AA Cox M-780 epoxy-fiberglass-asbestos disks (267 mm), K-27 yarn-wound fiberglass cartridges + AA Cox M-780 disks (127 mm), and Balston epoxy-fiberglass tubes (24.5 by 63.5 mm). The filters were used to concentrate seeded poliovirus from 380 liters of finished drinking water. Sodium thiosulfate was added to the drinking water to neutralize chlorine, and hydrochloric acid was added to adjust the pH to 3.5. Virus was eluted from the filters with glycine-NaOH buffer at pH 11.5. In terms of virus recovery efficiency, the filter media ranked Balston > Cox 267-mm > MF 293-mm ≃ K-27 + Cox 127-mm, but differences were slight. The Balston filters and holders were also superior to the other systems in terms of size, weight, cost, and handling factors. Experiments with 2- and 8-μm porosity Balston filters showed no statistically significant difference in virus recovery. Virus was readily detected by the Balston and the MF 293-mm systems at input levels of 12 to 22 PFU/1,900 liters. Preliminary experiments indicated that an elution pH lower than 11.5 may be satisfactory. PMID:167662

  13. The Alkaline Diet: Is There Evidence That an Alkaline pH Diet Benefits Health?

    PubMed Central

    Schwalfenberg, Gerry K.

    2012-01-01

    This review looks at the role of an alkaline diet in health. Pubmed was searched looking for articles on pH, potential renal acid loads, bone health, muscle, growth hormone, back pain, vitamin D and chemotherapy. Many books written in the lay literature on the alkaline diet were also reviewed and evaluated in light of the published medical literature. There may be some value in considering an alkaline diet in reducing morbidity and mortality from chronic diseases and further studies are warranted in this area of medicine. PMID:22013455

  14. Filter holder and gasket assembly for candle or tube filters

    DOEpatents

    Lippert, T.E.; Alvin, M.A.; Bruck, G.J.; Smeltzer, E.E.

    1999-03-02

    A filter holder and gasket assembly are disclosed for holding a candle filter element within a hot gas cleanup system pressure vessel. The filter holder and gasket assembly includes a filter housing, an annular spacer ring securely attached within the filter housing, a gasket sock, a top gasket, a middle gasket and a cast nut. 9 figs.

  15. Filter holder and gasket assembly for candle or tube filters

    DOEpatents

    Lippert, Thomas Edwin; Alvin, Mary Anne; Bruck, Gerald Joseph; Smeltzer, Eugene E.

    1999-03-02

    A filter holder and gasket assembly for holding a candle filter element within a hot gas cleanup system pressure vessel. The filter holder and gasket assembly includes a filter housing, an annular spacer ring securely attached within the filter housing, a gasket sock, a top gasket, a middle gasket and a cast nut.

  16. Cigarette Filter-based Assays as Proxies for Toxicant Exposure and Smoking Behavior A Literature Review

    PubMed Central

    Pauly, John L.; O’Connor, Richard J.; Paszkiewicz, Geraldine M.; Cummings, K. Michael; Djordjevic, Mirjana V.; Shields, Peter G.

    2009-01-01

    Background Cigarettes are being marketed with filters that differ in composition and design. The filters have different toxicant trapping efficiency and smoking stains reflect variations in smoking behavior. Presented herein are the results of a structured literature review that was performed to identify cigarette filter-based assays that may serve as proxies for mouth-level exposure and assessing smoking methods. Methods A search of the published scientific literature and internal tobacco company documents from 1954 to 2009 was performed. Results The literature search identified diverse schemes for assessing cigarette filters, including visual inspection and digital imaging of smoked-stained spent filters, and quantitative determinations for total particulate matter (TPM), nicotine, and solanesol. The results also showed that: (a) there is sufficient data to link filter-based chemical measures to standardized smoking machine-measured yields of tar and nicotine; (b) TPM eluted from filters or in chemical digest of filters can be used to estimate the efficiency of the filter for trapping smoke solids; (c) visual and digital inspection of spent filters are useful as indicators of variations in smoking behaviors; and (d) there is a correlation between solanesol and nicotine measured in filters and exposure biomarkers in smokers. Conclusions The cigarette filter may prove useful in estimating smoking behaviors such as filter vent blocking and puffing intensity, and may have utility as proxy measures of mouth-level smoke exposure in clinical trials. Additional investigations are needed to compare the different proposed assay schemes and the assay results with measurements of human biomarker assays of smoke exposure. PMID:19959679

  17. The Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence.

    PubMed

    Chisari, Alberto; Pistritto, Anna Maria; Piccolo, Raffaele; La Manna, Alessio; Danzi, Gian Battista

    2016-01-01

    The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) and the abluminal gradient coating technology are additional novel features of this coronary device. The Ultimaster DES has undergone extensive clinical evaluation in two studies: The CENTURY I and II trials. Results from these two landmark studies suggested an excellent efficacy and safety profile of the Ultimaster DES across several lesion and patient subsets, with similar clinical outcomes to contemporary, new-generation DES. The aim of this review is to summarize the rationale behind this novel DES technology and to provide an update of available evidence about the clinical performance of the Ultimaster DES. PMID:27608017

  18. Everolimus-eluting stent platforms in percutaneous coronary intervention: comparative effectiveness and outcomes.

    PubMed

    Panoulas, Vasileios F; Mastoris, Ioannis; Konstantinou, Klio; Tespili, Maurizio; Ielasi, Alfonso

    2015-01-01

    Despite the remarkable benefits obtained following the introduction of the first-generation drug-eluting stent (DES), concerns were raised over its long-term safety, particularly with regard to very late (beyond 1 year) stent thrombosis. Newer-generation DESs have been developed to overcome this limitation using novel stent platforms, new drugs, more biocompatible durable polymers, and bioabsorbable polymers or backbones. To date, new-generation DESs have virtually replaced the use of first-generation DESs worldwide. In this review article, we discuss in detail the design, pharmacology, and mechanism of action of the newer-generation permanent and bioresorbable everolimus-eluting platforms. Furthermore, we present and evaluate the current evidence on the performance and safety of these devices compared to those of other available stent platforms. PMID:26244031

  19. Acoustophoretic microfluidic chip for sequential elution of surface bound molecules from beads or cells

    PubMed Central

    Augustsson, Per; Malm, Johan; Ekström, Simon

    2012-01-01

    An acoustophoresis-based microfluidic flow-chip is presented as a novel platform to facilitate analysis of proteins and peptides loosely bound to the surface of beads or cells. The chip allows for direct removal of the background surrounding the beads or cells, followed by sequential treatment and collection of a sequence of up to five different buffer conditions. During this treatment, the beads/cells are retained in a single flow by acoustic radiation force. Eluted peptides are collected from the outlets and subsequently purified by miniaturized solid-phase extraction and analyzed with matrix assisted laser desorption mass spectrometry. Fundamental parameters such as the system fluidics and dispersion are presented. The device was successfully applied for wash and sequential elution of peptides bound to the surface of microbeads and human spermatozoa, respectively. PMID:24003343

  20. Advantages of novel BioMimeTM Sirolimus Eluting Coronary Stent system. Moving towards biomimicry.

    PubMed

    Upendra, K; Sanjeev, B

    2012-02-01

    Since the first reported use of percutaneous transluminal coronary angioplasty (PTCA), advancements in interventional cardiology arena have been fast paced. Within the last ten years, these developments have been exponential. Developers & clinicians are fast adapting from the learning curve awarded by the time course of DES evolution. In that light BioMimeTM Sirolimus Eluting Coronary Stent comes as a fresh thought in taking stents towards a biomimicry concept. The stent is built on an ultra-low strut thickness (65 µm) cobalt chromium stent platform, using an intelligent hybrid of close and open cells allowing for morphology mediated expansion, employs a well known anti-proliferative - Sirolimus that elutes from a biodegradable co-polymer formulation in 30 days and ensures high coating integrity and low coating thickness of 2 µm. The resultant stent demonstrates almost 100% endothelialization at 30 days in preclinical model and zero percent MACE >18 months in the primary efficacy and safety clinical study. PMID:22322571

  1. Leaching potential of phenylurea herbicides in a calcareous soil: comparison of column elution and batch studies.

    PubMed

    Langeron, Julie; Sayen, Stéphanie; Couderchet, Michel; Guillon, Emmanuel

    2014-04-01

    The transfer of eleven phenylurea herbicides through soil columns was investigated in laboratory conditions in order to determine leaching properties in a calcareous soil. Elution curves with distilled water were plotted after herbicide application on the soil column. Phenylurea retention by the soil indicating interactions with soil can be classified as follows: fenuron < fluometron ≤ isoproturon = monuron < metoxuron < monolinuron < metobromuron < chlorotoluron < linuron = diuron < chlorbromuron. The number and nature of halogen atoms on the phenyl ring had an important influence on leaching. Retention was higher for molecules with higher number of halogen, and it was also higher for bromine than chlorine. Column elution experiments were compared to batch experiments from which the distribution coefficients K d were determined. According to Kendall correlation coefficients, parameter m/m 0 max from column experiments was relatively well linked to K d. In case of phenylurea, a linear relationship between K d and m/m 0 max was established. PMID:23097070

  2. Everolimus-eluting stent platforms in percutaneous coronary intervention: comparative effectiveness and outcomes

    PubMed Central

    Panoulas, Vasileios F; Mastoris, Ioannis; Konstantinou, Klio; Tespili, Maurizio; Ielasi, Alfonso

    2015-01-01

    Despite the remarkable benefits obtained following the introduction of the first-generation drug-eluting stent (DES), concerns were raised over its long-term safety, particularly with regard to very late (beyond 1 year) stent thrombosis. Newer-generation DESs have been developed to overcome this limitation using novel stent platforms, new drugs, more biocompatible durable polymers, and bioabsorbable polymers or backbones. To date, new-generation DESs have virtually replaced the use of first-generation DESs worldwide. In this review article, we discuss in detail the design, pharmacology, and mechanism of action of the newer-generation permanent and bioresorbable everolimus-eluting platforms. Furthermore, we present and evaluate the current evidence on the performance and safety of these devices compared to those of other available stent platforms. PMID:26244031

  3. Recovery of functional DNA inserts by electroendosmotic elution during gel electrophoresis.

    PubMed Central

    Tan, H V; Kitzis, A; Berthollet, T; Hamard, G; Beldjord, C; Benarous, R

    1988-01-01

    In contrast to all previous preparative electrophoresis apparatus which used a pump, electroendosmotic elution uses bound electrical charges at the end of the separating gel to generate a buffer flow. The electroendosmotic flow increased with increasing currents and decreasing buffer concentrations: its exact characteristics for the built apparatus were determined. The electroendosmotic device was able to separate two DNA fragments differing in size by only 5% with a recovery over 95%. As demonstrated in practical examples of recovery and uses of DNA inserts, up to 10 micrograms of DNA per band can be loaded at a time. The recovered DNA can be used directly for nick-translation, ligation... without further treatment. The performances of the method are expected to improve still further if the charge density and pores of the electroendosmotic medium can be "made-to-order" to provide a better flow profile of the eluting buffer. Images PMID:2833722

  4. Dual delivery of active antibactericidal agents and bone morphogenetic protein at sustainable high concentrations using biodegradable sheath-core-structured drug-eluting nanofibers

    PubMed Central

    Hsu, Yung-Hen; Lin, Chang-Tun; Yu, Yi-Hsun; Chou, Ying-Chao; Liu, Shih-Jung; Chan, Err-Cheng

    2016-01-01

    In this study, we developed biodegradable sheath-core-structured drug-eluting nanofibers for sustainable delivery of antibiotics (vancomycin and ceftazidime) and recombinant human bone morphogenetic protein (rhBMP-2) via electrospinning. To prepare the biodegradable sheath-core nanofibers, we first prepared solutions of poly(d,l)-lactide-co-glycolide, vancomycin, and ceftazidime in 1,1,1,3,3,3-hexafluoro-2-propanol and rhBMP-2 in phosphate-buffered solution. The poly(d,l)-lactide-co-glycolide/antibiotics and rhBMP-2 solutions were then fed into two different capillary tubes controlled by two independent pumps for coaxial electrospinning. The electrospun nanofiber morphology was observed under a scanning electron microscope. We further characterized the in vitro antibiotic release from the nanofibers via high-performance liquid chromatography and that of rhBMP-2 via enzyme-linked immunosorbent assay and alkaline phosphatase activity. We showed that the biodegradable coaxially electrospun nanofibers could release high vancomycin/ceftazidime concentrations (well above the minimum inhibition concentration [MIC]90) and rhBMP-2 for >4 weeks. These experimental results demonstrate that novel biodegradable nanofibers can be constructed with various pharmaceuticals and proteins for long-term drug deliveries. PMID:27574423

  5. Dual delivery of active antibactericidal agents and bone morphogenetic protein at sustainable high concentrations using biodegradable sheath-core-structured drug-eluting nanofibers.

    PubMed

    Hsu, Yung-Hen; Lin, Chang-Tun; Yu, Yi-Hsun; Chou, Ying-Chao; Liu, Shih-Jung; Chan, Err-Cheng

    2016-01-01

    In this study, we developed biodegradable sheath-core-structured drug-eluting nanofibers for sustainable delivery of antibiotics (vancomycin and ceftazidime) and recombinant human bone morphogenetic protein (rhBMP-2) via electrospinning. To prepare the biodegradable sheath-core nanofibers, we first prepared solutions of poly(d,l)-lactide-co-glycolide, vancomycin, and ceftazidime in 1,1,1,3,3,3-hexafluoro-2-propanol and rhBMP-2 in phosphate-buffered solution. The poly(d,l)-lactide-co-glycolide/antibiotics and rhBMP-2 solutions were then fed into two different capillary tubes controlled by two independent pumps for coaxial electrospinning. The electrospun nanofiber morphology was observed under a scanning electron microscope. We further characterized the in vitro antibiotic release from the nanofibers via high-performance liquid chromatography and that of rhBMP-2 via enzyme-linked immunosorbent assay and alkaline phosphatase activity. We showed that the biodegradable coaxially electrospun nanofibers could release high vancomycin/ceftazidime concentrations (well above the minimum inhibition concentration [MIC]90) and rhBMP-2 for >4 weeks. These experimental results demonstrate that novel biodegradable nanofibers can be constructed with various pharmaceuticals and proteins for long-term drug deliveries. PMID:27574423

  6. Optimizing the performance of bandpass photon detectors for inverse photoemission: Transmission of alkaline earth fluoride window crystals

    SciTech Connect

    Thiede, Christian Schmidt, Anke B.; Donath, Markus

    2015-08-15

    Bandpass photon detectors are widely used in inverse photoemission in the isochromat mode at energies in the vacuum-ultraviolet spectral range. The energy bandpass of gas-filled counters is usually formed by the ionization threshold of the counting gas as high-pass filter and the transmission cutoff of an alkaline earth fluoride window as low-pass filter. The transmission characteristics of the window have, therefore, a crucial impact on the detector performance. We present transmission measurements in the vacuum-ultraviolet spectral range for alkaline earth fluoride window crystals in the vicinity of the transmission cutoff as a function of crystal purity, surface finish, surface contamination, temperature, and thickness. Our findings reveal that the transmission characteristics of the window crystal and, thus, the detector performance depend critically on these window parameters.

  7. MERCURIC CHLORIDE CAPTURE BY ALKALINE SORBENTS

    EPA Science Inventory

    The paper gives results of bench-scale mechanistic studies of mercury/sorbent reactions that showed that mercuric chloride (HgC12) is readily adsorbed by alkaline sorbents, which may offers a less expensive alternative to the use of activated carbons. A laboratory-scale, fixed-b...

  8. Negative Electrode For An Alkaline Cell

    DOEpatents

    Coco, Isabelle; Cocciantelli, Jean-Michel; Villenave, Jean-Jacques

    1998-07-14

    The present invention concerns a negative electrode for an alkaline cell, comprising a current collector supporting a paste containing an electrochemically active material and a binder, characterized in that said binder is a polymer containing hydrophilic and hydrophobic groups, said polymer being selected from an acrylic homopolymer, copolymer and terpolymer, an unsaturated organic acid copolymer and an unsaturated acid anhydride copolymer.

  9. Kinetics of the alkaline hydrolysis of nitrocellulose.

    PubMed

    Christodoulatos, C; Su, T L; Koutsospyros, A

    2001-01-01

    Cellulose nitrate (nitrocellulose) is an explosive solid substance used in large quantities in various formulations of rocket and gun propellants. Safe destruction of nitrocellulose can be achieved by alkaline hydrolysis, which converts it to biodegradable products that can then be treated by conventional biological processes. The kinetics of the alkaline hydrolysis of munitions-grade nitrocellulose in sodium hydroxide solutions were investigated in completely mixed batch reactors. Experiments were conducted using solutions of alkaline strength ranging from 0.1 to 15% by mass and temperatures in the range of 30 to 90 degrees C. Regression analysis of the kinetic data revealed that alkaline hydrolysis of nitrocellulose is of the order 1.0 and 1.5 with respect to nitrocellulose and hydroxide concentration, respectively. The activation energy of the hydrolysis reaction was found to be 100.9 kJ/mol with a preexponential Arrhenius constant of 4.73 x 10(13). Nitrite and nitrate, in a 3:1 ratio, were the primary nitrogen species present in the posthydrolysis solution. The kinetic information is pertinent to the development and optimization of nitrocellulose chemical-biological treatment systems. PMID:11563378

  10. Use Alkalinity Monitoring to Optimize Bioreactor Performance.

    PubMed

    Jones, Christopher S; Kult, Keegan J

    2016-05-01

    In recent years, the agricultural community has reduced flow of nitrogen from farmed landscapes to stream networks through the use of woodchip denitrification bioreactors. Although deployment of this practice is becoming more common to treat high-nitrate water from agricultural drainage pipes, information about bioreactor management strategies is sparse. This study focuses on the use of water monitoring, and especially the use of alkalinity monitoring, in five Iowa woodchip bioreactors to provide insights into and to help manage bioreactor chemistry in ways that will produce desirable outcomes. Results reported here for the five bioreactors show average annual nitrate load reductions between 50 and 80%, which is acceptable according to established practice standards. Alkalinity data, however, imply that nitrous oxide formation may have regularly occurred in at least three of the bioreactors that are considered to be closed systems. Nitrous oxide measurements of influent and effluent water provide evidence that alkalinity may be an important indicator of bioreactor performance. Bioreactor chemistry can be managed by manipulation of water throughput in ways that produce adequate nitrate removal while preventing undesirable side effects. We conclude that (i) water should be retained for longer periods of time in bioreactors where nitrous oxide formation is indicated, (ii) measuring only nitrate and sulfate concentrations is insufficient for proper bioreactor operation, and (iii) alkalinity monitoring should be implemented into protocols for bioreactor management. PMID:27136151

  11. ISSUES WITH ALKALINE TREATMENT OF SLUDGE

    EPA Science Inventory

    This presentation begins with a discussion of the use of lime and other alkaline materials from the very earliest times to the present for killing bacteria, viruses and parasites and for controlling odors in wastewaters and sludge. It answers the question "How did EPA arrive at i...

  12. Alkaline electrochemical cells and method of making

    NASA Technical Reports Server (NTRS)

    Hoyt, H. E.; Pfluger, H. L. (Inventor)

    1970-01-01

    Equilibrated cellulose ether membranes of increased electrolytic conductivity for use as separators in concentrated alkaline electrochemical cells are investigated. The method of making such membranes by equilibration to the degree desired in an aqueous alkali solution mantained at a temperature below about 10 C is described.

  13. Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

    SciTech Connect

    Sakamoto, Susumu Kikuchi, Naoshi; Ichikawa, Atsuo; Sano, Go; Satoh, Keita; Sugino, Keishi; Isobe, Kazutoshi; Takai, Yujiro; Shibuya, Kazutoshi; Homma, Sakae

    2013-08-01

    Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

  14. Stent thrombosis with an aneurysm 7 years after a drug eluting stent implantation

    PubMed Central

    Patil, Pritam; Sethi, Arvind; Kaul, Upendra

    2014-01-01

    We report a case of very late stent thrombosis 7 years post sirolimus eluting stent implantation presenting as ST elevation MI while on dual antiplatelet therapy. Angiography revealed an aneurysm at the proximal end of the stent. The patient was managed successfully by primary percutaneous coronary intervention (PCI) with adjunct thrombus aspiration and intracoronary abciximab administration followed by deploying a mesh-covered stent MGuard. This very late complication is a rare presentation after a drug illuting stent (DES). PMID:24814120

  15. Hepatic Arterial Chemoembolization Using Drug-Eluting Beads in Gastrointestinal Neuroendocrine Tumor Metastatic to the Liver

    SciTech Connect

    Gaur, Shantanu K.; Friese, Jeremy L.; Sadow, Cheryl A.; Ayyagari, Rajasekhara; Binkert, Christoph A.; Schenker, Matthew P.; Kulke, Matthew; Baum, Richard

    2011-06-15

    Purpose: This study was designed to evaluate short (<3 months) and intermediate-term (>3 months) follow-up in patients with metastatic neuroendocrine tumor to the liver who underwent hepatic arterial chemoembolization with drug-eluting beads at a single institution. Methods: Institutional review board approval was obtained for this retrospective review. All patients who were treated with 100-300 or 300-500 {mu}m drug-eluting LC Beads (Biocompatibles, UK) preloaded with doxorubicin (range, 50-100 mg) for GI neuroendocrine tumor metastatic to the liver from June 2004 to June 2009 were included. CT and MRI were evaluated for progression using Response Evaluation Criteria In Solid Tumors (RECIST) or European Association for the Study of the Liver (EASL) criteria. Short-term (<3 months) and intermediate-term (>3 months) imaging response was determined and Kaplan-Meier survival curves were plotted. Results: Thirty-eight drug-eluting bead chemoembolization procedures were performed on 32 hepatic lobes, comprising 21 treatment cycles in 18 patients. All procedures were technically successful with two major complications (biliary injuries). At short-term follow-up (<3 months), 22 of 38 (58%) procedures and 10 of 21 (48%) treatment cycles produced an objective response (OR) with the remainder having stable disease (SD). At intermediate-term follow-up (mean, 445 days; range, 163-1247), 17 of 26 (65%) procedures and 8 of 14 (57%) treatment cycles produced an OR. Probability of progressing was approximately 52% at 1 year with a median time to progression of 419 days. Conclusions: Drug-eluting bead chemoembolization is a reasonable alternative to hepatic arterial embolization and chemoembolization for the treatment of metastatic neuroendocrine tumor to the liver.

  16. Downflow dust filter

    SciTech Connect

    Richard, K.L.

    1986-09-09

    This patent describes an industrial dust filter apparatus comprising: a housing including upper, intermediate and lower sections, the upper section having a top opening inlet for particulate laden gases and the lower section tapering downwardly to a particulate outlet; a plurality of vertically arranged substantially cylindrical filters supported in substantially parallel relationship to each other in the intermediate section of the housing, the filters being closed at their upper ends and having their exterior filter surfaces exposed to particulate laden gases from the inlet; at least one horizontal duct extending across the housing beneath the filters, closed at one end and opening at its other end to a clean gas outlet through a side wall of the intermediate housing section; means communicating the lower open end of the filters through the upper walls of the duct so that the duct functions as a clean gas plenum; a plurality of verturis, vertically supported in the duct, on aligned with each filter; and means in the duct for pulse firing a jet of air upwardly through the venturis into the interior of the filters to remove particulates from the outer surfaces thereof.

  17. Filtering reprecipitated slurry

    SciTech Connect

    Morrissey, M.F.

    1992-12-31

    As part of the Late Washing Demonstration at Savannah River Technology Center, Interim Waste Technology has filtered reprecipitated and non reprecipitated slurry with the Experimental Laboratory Filter (ELF) at TNX. Reprecipitated slurry generates higher permeate fluxes than non reprecipitated slurry. Washing reprecipitated slurry may require a defoamer because reprecipitation encourages foaming.

  18. Filtering reprecipitated slurry

    SciTech Connect

    Morrissey, M.F.

    1992-01-01

    As part of the Late Washing Demonstration at Savannah River Technology Center, Interim Waste Technology has filtered reprecipitated and non reprecipitated slurry with the Experimental Laboratory Filter (ELF) at TNX. Reprecipitated slurry generates higher permeate fluxes than non reprecipitated slurry. Washing reprecipitated slurry may require a defoamer because reprecipitation encourages foaming.

  19. Active rejector filter

    SciTech Connect

    Kuchinskii, A.G.; Pirogov, S.G.; Savchenko, V.M.; Yakushev, A.K.

    1985-01-01

    This paper describes an active rejector filter for suppressing noise signals in the frequency range 50-100 Hz and for extracting a vlf information signal. The filter has the following characteristics: a high input impedance, a resonant frequency of 75 Hz, a Q of 1.25, and an attenuation factor of 53 dB at resonant frequency.

  20. The role of CABG in the era of drug-eluting stents: a surgeon's viewpoint

    PubMed Central

    Teoh, L K Kristine; Lee, Chuen Neng

    2010-01-01

    Advances in transcatheter technologies, from balloon angioplasty to bare metal stents to drug-eluting stents, have resulted in improved outcomes following percutaneous coronary intervention (PCI). As a consequence, the differences in outcomes between coronary artery bypass graft surgery (CABG) and PCI have become less significant over short-term follow-up. In addition, the number of patients undergoing coronary revascularisation with PCI has increased and far exceeds that of CABG, which has declined, the ratio stabilising in recent years. With the advent of drug-eluting stents and the increasing off-label use of these stents—and in the setting of questionable public awareness of the relative risks and benefits of the therapeutic options of optimal medical treatment and revascularisation by PCI or CABG—the role of CABG requires clarification and reaffirmation. Recent clinical trials have helped to better define the relative benefits of each treatment modality. The mid- and long-term results of these studies remain to be seen, however, while the evidence for the role of PCI in left main stem disease remains inconclusive at the present time. In this context of continually emerging clinical evidence, this review seeks to provide a balanced opinion regarding the role of CABG in the era of drug-eluting stents.

  1. In vitro hemocompatibility and cytocompatibility of dexamethasone-eluting PLGA stent coatings

    NASA Astrophysics Data System (ADS)

    Zhang, Jiang; Liu, Yang; Luo, Rifang; Chen, Si; Li, Xin; Yuan, Shuheng; Wang, Jin; Huang, Nan

    2015-02-01

    Drug-eluting stents (DESs) have been an important breakthrough for interventional cardiology applications since 2002. Though successful in reducing restenosis, some adverse clinical problems still emerged, which were mostly caused by the bare-metal stents and non-biodegradable polymer coatings, associated with the delayed endothelialization process. In this study, dexamethasone-loaded poly (lactic-co-glycolic acid) (PLGA) coatings were developed to explore the potential application of dexamethasone-eluting stents. Dexamethasone-eluting PLGA stents were prepared using ultrasonic atomization spray method. For other tests like stability and cytocompatibility and hemocompatibility tests, dexamethasone loaded coatings were deposited on 316L SS wafers. Fourier transform-infrared spectroscopy (FT-IR) results demonstrated that there was no chemical reaction between PLGA and dexamethasone. The balloon expansion experiment and surface morphology observation suggested that the stent coatings were smooth and uniform, and could also withstand the compressive and tensile strains imparted without cracking after stent expansion. The drug release behavior in vitro indicated that dexamethasone existed burst release within 1 day, but it presented linear release characteristics after 6 days. In vitro platelets adhesion, activation test and APTT test were also done, which showed that after blending dexamethasone into PLGA, the hemocompatibility was improved. Besides, dexamethasone and dexamethasone-loaded PLGA coatings could significantly inhibit the attachment and proliferation of smooth muscle cells.

  2. Elution kinetics, antimicrobial activity, and mechanical properties of 11 different antibiotic loaded acrylic bone cement.

    PubMed

    Gálvez-López, Ruben; Peña-Monje, Alejandro; Antelo-Lorenzo, Ramón; Guardia-Olmedo, Juan; Moliz, Juan; Hernández-Quero, José; Parra-Ruiz, Jorge

    2014-01-01

    Antibiotic-loaded acrylic bone cements (ALABC) spacers are routinely used in the treatment of prosthetic joint infections. The objectives of our study were to evaluate different ALABC for elution kinetics, thermal stability, and mechanical properties. A 10 or 20% mixture (w/w) beads of medium viscosity bone cement (DePuy, Inc) and vancomycin (VAN), gentamycin (GM), daptomycin (DAP), moxifloxacin (MOX), rifampicin (RIF), cefotaxime (CTX), cefepime (FEP), amoxicillin clavulanate (AmC), ampicillin (AMP), meropenem (MER), and ertapenem (ERT) were formed and placed into wells filled with phosphate-buffered saline. Antibiotic concentrations were determined using high-performance liquid chromatography. Antimicrobial activity was tested against Micrococcus luteus ATCC 9341 or Escherichia coli ATCC 25922. AmC, AMP, and FEP concentration rapidly decreased after day 2, being almost undetectable at day 4. Sustained and high elution rates were observed with VAN, GM, MOX, and RIF for the 30-day duration of the experiment. DAP, MER, ERT, and CTX elution rates constantly decreased from day 4. All antibiotics tested retained antimicrobial activity proving thermal stability. Mechanical properties of ALABC were maintained except when RIF was used. PMID:24231380

  3. Drug-eluting microarrays to identify effective chemotherapeutic combinations targeting patient-derived cancer stem cells

    PubMed Central

    Carstens, Matthew R.; Fisher, Robert C.; Acharya, Abhinav P.; Butterworth, Elizabeth A.; Scott, Edward; Huang, Emina H.; Keselowsky, Benjamin G.

    2015-01-01

    A new paradigm in oncology establishes a spectrum of tumorigenic potential across the heterogeneous phenotypes within a tumor. The cancer stem cell hypothesis postulates that a minute fraction of cells within a tumor, termed cancer stem cells (CSCs), have a tumor-initiating capacity that propels tumor growth. An application of this discovery is to target this critical cell population using chemotherapy; however, the process of isolating these cells is arduous, and the rarity of CSCs makes it difficult to test potential drug candidates in a robust fashion, particularly for individual patients. To address the challenge of screening drug libraries on patient-derived populations of rare cells, such as CSCs, we have developed a drug-eluting microarray, a miniaturized platform onto which a minimal quantity of cells can adhere and be exposed to unique treatment conditions. Hundreds of drug-loaded polymer islands acting as drug depots colocalized with adherent cells are surrounded by a nonfouling background, creating isolated culture environments on a solid substrate. Significant results can be obtained by testing <6% of the cells required for a typical 96-well plate. Reliability was demonstrated by an average coefficient of variation of 14% between all of the microarrays and 13% between identical conditions within a single microarray. Using the drug-eluting array, colorectal CSCs isolated from two patients exhibited unique responses to drug combinations when cultured on the drug-eluting microarray, highlighting the potential as a prognostic tool to identify personalized chemotherapeutic regimens targeting CSCs. PMID:26124098

  4. In Vitro Elution Characteristics of Gentamicin and Vancomycin from Synthetic Bone Graft Substitutes

    PubMed Central

    Maier, Gerrit Steffen; Roth, Klaus Edgar; Andereya, Stefan; Birnbaum, Klaus; Niedhart, Christopher; Lühmann, Markus; Ohnsorge, Jörg; Maus, Uwe

    2013-01-01

    Objects: Beta tricalciumphosphate pellets loaded with individualized antibiotics may represent novel options in the treatment of osteomyelitis and infectious bone disease. Here, the in vitro antibiotic elution of vancomycin and gentamicin from the synthetic bone graft substitutes Cerasorb® and Cerasorb M® was tested. Methods: Antibiotic elution and concentration of gentamcin and vancomycin were measured using photometrically-based measurement and homogeneous particle-enhanced turbidimetric inhibition immunoassays (PETINIA). Results: Initially both materials showed a high release of the loaded antibiotics, with Cerasorb M® showing lower release levels for gentamicin and vancomycin than Cerasorb®. Gentamicin concentrations of Cerasorb M granules and Cerasorb were below the minimum detectiontreshold until day four and six of the experiment respectively. The vancomycin release-level followed a similar pattern, although the vancomycin concentration eluted by Cerasorb M® granules stayed above the detection threshold during the experimental time. Conclusions: Cerasorb® and Cersorb M® may represent a new treatment option in osteomyelitis and infectious bone disease. PMID:24285988

  5. Blood compatibility assessment of polymers used in drug eluting stent coatings.

    PubMed

    Szott, Luisa Mayorga; Irvin, Colleen A; Trollsas, Mikael; Hossainy, Syed; Ratner, Buddy D

    2016-06-01

    Differences in thrombosis rates have been observed clinically between different drug eluting stents. Such differences have been attributed to numerous factors, including stent design, injury created by the catheter delivery system, coating application technologies, and the degree of thrombogenicity of the polymer. The relative contributions of these factors are generally unknown. This work focuses on understanding the thrombogenicity of the polymer by examining mechanistic interactions with proteins, human platelets, and human monocytes of a number of polymers used in drug eluting stent coatings, in vitro. The importance for blood interactions of adsorbed albumin and the retention of albumin was suggested by the data. Microscopic imaging and immunostaining enhanced the interpretation of results from the lactate dehydrogenase cell counting assay and provided insight into platelet interactions, total quantification, and morphometry. In particular, highly spread platelets may be surface-passivating, possibly inhibiting ongoing thrombotic events. In many of the assays used here, poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) showed a differentiated protein deposition pattern that may contribute to the explanation of the consistently thromboresistant blood-materials interaction for fluororpolymers cited in literature. These results are supportive of one of several possible factors contributing to the good thromboresistant clinical safety performance of PVDF-HFP coated drug eluting stents. PMID:27083991

  6. Purification of 3-phosphoglycerate kinase from diverse sources by affinity elution chromatography.

    PubMed Central

    Fifis, T; Scopes, R K

    1978-01-01

    1. Affinity elution chromatography was used to purify phosphoglycerate kinase from a variety of sources. The choice of buffer pH for the chromatography was made according to the relative electrophoretic mobility of the enzyme from the species concerned. 2. Outlines of the methods used to isolate the enzyme from over 20 sources are presented. The enzyme was purified from the muscle tissue of a variety of mammals, fish and birds, from liver of several animals, from yeast, Escherichia coli, and plant leaves. The more acidic varieties of the enzymes were purified by conventional gradient elution from ion-exchangers as affinity elution procedures were not applicable. 3. The structural and kinetic parameters investigated show that phosphoglycerate kinase is evolutionarily a highly conservative enzyme; there were few differences in properties regardless of source or function (glycolytic, gluconeogenic or photosynthetic). 4. A detailed comparison of the enzyme preparations purified from bovine muscle and bovine liver failed to detect any significant differences between them; the evidence indicates that they are genetically identical. PMID:367367

  7. The pre-clinical assessment of rapamycin-eluting, durable polymer-free stent coating concepts.

    PubMed

    Steigerwald, Kristin; Merl, Sabine; Kastrati, Adnan; Wieczorek, Anna; Vorpahl, Marc; Mannhold, Raimund; Vogeser, Michael; Hausleiter, Jörg; Joner, Michael; Schömig, Albert; Wessely, Rainer

    2009-02-01

    All four currently FDA-approved drug-eluting stents (DESs) contain a durable polymeric coating which can negatively impact vascular healing processes and eventually lead to adverse cardiac events. Aim of this study was the pre-clinical assessment of two novel rapamycin-eluting stent (RES) coating technologies that abstain from use of a durable polymer. Two distinctive RES coating technologies were evaluated in vitro and in the porcine coronary artery stent model. The R-poly(S) stent platform elutes rapamycin from a biodegradable polymer that is top coated with the resin shellac to minimize the amount of polymer. The R-pro(S) stent platform allows dual drug release of rapamycin and probucol, blended by shellac. HPLC-based determination of pharmacokinetics indicated drug release for more than 28 days. At 30 days, neointimal formation was found to be significantly decreased for both DESs compared to bare-metal stents. Assessment of vascular healing revealed absence of increased inflammation in both DESs, which is commonly observed in DES with non-erodible polymeric coating. In conclusion, the pre-clinical assessment of RESs with resin-based or dual drug coating indicated an adequate efficacy profile as well as a beneficial effect for vascular healing processes. These results encourage the transfer of these technologies to clinical evaluation. PMID:18990438

  8. Drug-eluting balloon: Initial experience in patients with in-stent restenosis (ISR)

    PubMed Central

    Swamy, A.J.; Kumar, Anil; Keshavamurthy, G.; Chadha, D.S.

    2014-01-01

    Background In-stent restenosis is the most important limitation of modern coronary angioplasty. Drug-eluting stents solve this problem but at the cost of late stent thrombosis and longer duration of dual-antiplatelet therapy. Drug-eluting balloon (DEB) technology is now available and offers an attractive option for treatment of restenosis. Methods A cohort of 20 patients with in-stent restenosis after stenting were treated with a drug-eluting balloon and were followed up clinically and angiographically for 6 months. Results and conclusion Procedural success was achieved in all patients. 6 month clinical follow-up was available for all and 6 month angiographic follow up for 17 patients. On 6 month follow-up, 5 of the 20 patients had recurrence of angina and 4 patients had angiographic restenosis (2 focal, 2 diffuse). The mean Canadian Cardiovascular Society angina score improved significantly from 3.1 to 1.1. DEB offers a novel method of treatment for patients with in-stent restenosis with a good safety and efficacy profile. PMID:25378777

  9. Very Late Stent Thrombosis 11 Years after Implantation of a Drug-Eluting Stent

    PubMed Central

    Jepson, Nigel

    2015-01-01

    Very late stent thrombosis is an infrequent yet potentially fatal complication associated with drug-eluting stents. We report the case of an 88-year-old man who sustained an ST-segment-elevation myocardial infarction 11 years after initial sirolimus-eluting stent implantation. Optical coherence tomograms of the lesion showed that the focal incomplete endothelialization of the stent struts was the likely cause; neointimal formation, neoatherosclerosis, and late stent malapposition might also have contributed. To our knowledge, this is the longest reported intervening period between stent insertion and the development of an acute coronary event secondary to very late stent thrombosis. The associated prognostic and therapeutic implications are considerable, because they illuminate the uncertainties surrounding the optimal duration of antiplatelet therapy in patients who have drug-eluting stents. Clinicians face challenges in treating these patients, particularly when competing medical demands necessitate the discontinuation of antiplatelet therapy. In addition to the patient's case, we discuss factors that can contribute to very late stent thrombosis. PMID:26504449

  10. Sintered composite filter

    DOEpatents

    Bergman, W.

    1986-05-02

    A particulate filter medium formed of a sintered composite of 0.5 micron diameter quartz fibers and 2 micron diameter stainless steel fibers is described. Preferred composition is about 40 vol.% quartz and about 60 vol.% stainless steel fibers. The media is sintered at about 1100/sup 0/C to bond the stainless steel fibers into a cage network which holds the quartz fibers. High filter efficiency and low flow resistance are provided by the smaller quartz fibers. High strength is provided by the stainless steel fibers. The resulting media has a high efficiency and low pressure drop similar to the standard HEPA media, with tensile strength at least four times greater, and a maximum operating temperature of about 550/sup 0/C. The invention also includes methods to form the composite media and a HEPA filter utilizing the composite media. The filter media can be used to filter particles in both liquids and gases.

  11. Sub-micron filter

    DOEpatents

    Tepper, Frederick; Kaledin, Leonid

    2009-10-13

    Aluminum hydroxide fibers approximately 2 nanometers in diameter and with surface areas ranging from 200 to 650 m.sup.2/g have been found to be highly electropositive. When dispersed in water they are able to attach to and retain electronegative particles. When combined into a composite filter with other fibers or particles they can filter bacteria and nano size particulates such as viruses and colloidal particles at high flux through the filter. Such filters can be used for purification and sterilization of water, biological, medical and pharmaceutical fluids, and as a collector/concentrator for detection and assay of microbes and viruses. The alumina fibers are also capable of filtering sub-micron inorganic and metallic particles to produce ultra pure water. The fibers are suitable as a substrate for growth of cells. Macromolecules such as proteins may be separated from each other based on their electronegative charges.

  12. Implicit Kalman filtering

    NASA Technical Reports Server (NTRS)

    Skliar, M.; Ramirez, W. F.

    1997-01-01

    For an implicitly defined discrete system, a new algorithm for Kalman filtering is developed and an efficient numerical implementation scheme is proposed. Unlike the traditional explicit approach, the implicit filter can be readily applied to ill-conditioned systems and allows for generalization to descriptor systems. The implementation of the implicit filter depends on the solution of the congruence matrix equation (A1)(Px)(AT1) = Py. We develop a general iterative method for the solution of this equation, and prove necessary and sufficient conditions for convergence. It is shown that when the system matrices of an implicit system are sparse, the implicit Kalman filter requires significantly less computer time and storage to implement as compared to the traditional explicit Kalman filter. Simulation results are presented to illustrate and substantiate the theoretical developments.

  13. Multidimensional synthetic estimation filter

    NASA Technical Reports Server (NTRS)

    Monroe, Stanley E., Jr.; Juday, Richard D.

    1990-01-01

    The synthetic estimation filter (SEF) crafts an affine variation into its response to a changing parameter (e.g. scale or rotation). Sets of such filters are used in an estimation correlator to reduce the number of filters required for a given tracking accuracy. By overspecifying the system (one more SEF than parameters to be tracked), the ratio of correlation responses between filters forms a robust estimator into the spanned domain of the parameters. Previous results dealt with a laboratory correlator which could track a single parameter. This paper explores the SEF and the estimator's extension to more dimensions. A 2D example is given in which a reduction of filters from 25 to 3 is demonstrated to span a 4-degree square portion of pose space.

  14. Information geometric nonlinear filtering

    NASA Astrophysics Data System (ADS)

    Newton, Nigel J.

    2015-06-01

    This paper develops information geometric representations for nonlinear filters in continuous time. The posterior distribution associated with an abstract nonlinear filtering problem is shown to satisfy a stochastic differential equation on a Hilbert information manifold. This supports the Fisher metric as a pseudo-Riemannian metric. Flows of Shannon information are shown to be connected with the quadratic variation of the process of posterior distributions in this metric. Apart from providing a suitable setting in which to study such information-theoretic properties, the Hilbert manifold has an appropriate topology from the point of view of multi-objective filter approximations. A general class of finite-dimensional exponential filters is shown to fit within this framework, and an intrinsic evolution equation, involving Amari's -1-covariant derivative, is developed for such filters. Three example systems, one of infinite dimension, are developed in detail.

  15. Titanium corrosion in alkaline hydrogen peroxide environments

    NASA Astrophysics Data System (ADS)

    Been, Jantje

    1998-12-01

    The corrosion of Grade 2 titanium in alkaline hydrogen peroxide environments has been studied by weight loss corrosion tests, electrochemical impedance spectroscopy (EIS), linear polarization resistance (LPR) measurements and potentiodynamic polarography. Calcium ions and wood pulp were investigated as corrosion inhibitors. In alkaline peroxide, the titanium corrosion rate increased with increasing pH, temperature, and hydrogen peroxide concentration. The corrosion controlling mechanism is thought to be the reaction of the oxide with the perhydroxyl ion. No evidence of thermodynamically stable calcium titanate was found in the surface film of test coupons exposed to calcium-inhibited alkaline peroxide solutions. Calcium inhibition is probably the result of low local alkali and peroxide concentrations at the metal surface produced by reaction of adsorbed calcium with hydrogen peroxide. It has been shown that the inhibiting effect of calcium is temporary, possibly through an effect of calcium on the chemical and/or physical stability of the surface oxide. Pulp is an effective and stable corrosion inhibitor. Raising the pulp concentration decreased the corrosion rate. The inhibiting effect of pulp may be related to the adsorption and interaction of the pulp fibers with H 2O2, thereby decreasing the peroxide concentration and rendering the solution less corrosive. The presence of both pulp and calcium led to higher corrosion rates than obtained by either one inhibitor alone. Replacement of hydrofluoric acid with alkaline peroxide for pickling of titanium was investigated. Titanium corrosion rates in alkaline peroxide exceeded those obtained in the conventional hydrofluoric acid bath. General corrosion was observed with extensive roughening of the surface giving a dull gray appearance. Preferred dissolution of certain crystallographic planes was investigated through the corrosion of a titanium single crystal. Whereas the overall effect on the corrosion rate was small

  16. ACTINIDE-ALUMINATE SPECIATION IN ALKALINE RADIOACTIVE WASTE

    EPA Science Inventory

    Highly alkaline radioactive waste tanks contain a number of transuranic species, in particular U, Np, Pu, and Am - the exact forms of which are currently unknown. Knowledge of actinide speciation under highly alkaline conditions is essential towards understanding and predicting ...

  17. A method for making an alkaline battery electrode plate

    NASA Technical Reports Server (NTRS)

    Chida, K.; Ezaki, T.

    1983-01-01

    A method is described for making an alkaline battery electrode plate where the desired active substances are filled into a nickel foam substrate. In this substrate an electrolytic oxidation reduction occurs in an alkaline solution containing lithium hydroxide.

  18. Protein adsorption to poly(ethylenimine)-modified Sepharose FF. IV. Dynamic adsorption and elution behaviors.

    PubMed

    Liu, Na; Yu, Lin-Ling; Sun, Yan

    2014-10-01

    We have previously investigated bovine serum albumin (BSA) uptake to poly(ethylenimine) (PEI)-grafted Sepharose FF. It was found that there was a critical ionic capacity (cIC; 600mmol/L) for BSA, above which the protein adsorption capacity and uptake kinetics increased drastically. In this work, two poly(ethylenimine) (PEI)-grafted resins with IC values of 271mmol/L (FF-PEI-L270) and 683mmol/L (FF-PEI-L680), which were below and above the cIC, respectively, were chosen to investigate the breakthrough and linear gradient elution (LGE) behaviors of BSA. Commercially available anion exchanger, Q Sepharose FF, was used for comparison. The DBC values of FF-PEI-L680 were much higher in the entire residence time range (2-10min) than the other two resins due to its high static adsorption capacity and uptake kinetics. At a residence time of 5.0min, the DBC of FF-PEI-L680 (104mg/mL) was about seven times that of FF-PEI-L270 and three times that of Q Sepharose FF. A rise-fall trend of the DBCs with increasing ionic strength (IS) was found for all the three resins studied, indicating the presence of electrostatic exclusion for protein uptake at low IS. With increasing NaCl concentration from 20 to 200mmol/L, FF-PEI-L680 kept very high DBC values (64-114mg/mL). In addition, FF-PEI-L270 showed more favorable adsorption properties than Q Sepharose FF at 100-300mmol/L NaCl. These results proved that the three-dimensional grafting ion exchange layer on the PEI resins enhanced their tolerance to IS. In the study of LGE, the three resins showed similar elution behaviors and no distinct peak tailings were observed. The salt concentrations at the elution peaks (IR) were in the order of FF-PEI-L680>FF-PEI-L270>Q Sepharose FF, indicating that the elution for the PEI resins needed higher salt concentrations, which was also an appearance of the salt-tolerant feature of the PEI resins. When protein loading amount was increased to the value equivalent to the DBC at 10% breakthrough, the

  19. Properties of Ceramic Filters

    SciTech Connect

    Spain, J.D.

    1996-12-31

    The mechanical integrity of ceramic filter elements is a key issue for hot gas cleanup systems. To meet the demands of advanced power systems, the filter components sustain thermal stresses of normal operations (pulse cleaning), of start-up and shut-down, and of process upsets such as excessive ash accumulation without catastrophic failure. They must also survive various mechanical loads associated with handling and assembly, normal operation, and process upsets. For near-term filter systems, the elements must also survive operating temperature of 1650{degrees}F for three years. Objectives of the testing conducted were as follows: (1) measure basic physical, mechanical and thermal properties of candle filter materials and relate these properties to in-service performance, (2) perform post-exposure testing of candle-filter materials after service at Tidd and Karhula and compare post-exposure results to as-manufactured results to evaluate property degradation, (3) based on measured properties and in-service performance, develop an understanding of material requirements for candle-filter materials and help establish property goals, and (4) establish a test protocol for evaluation of candle filter materials.

  20. Method of filtering

    SciTech Connect

    White, H.R.

    1985-04-09

    This invention provides a non-fibrous combustible filter aid for vacuum pre-coat filter units which is effective to maintain a filter bed coating on rotary filter drums just sufficiently porous to pass the liquid of a slurry while retaining the slurry solids thereon and is capable of being scraped off the bed in thin film form with the slurry solids thereon. The filter aid comprises relatively non-compressible non-fibrous granular charcoal or nut shell particles having a dry bulk density from about 0.3 to about 0.6 grams per cubic centimeter, a particle density of about 1.4 to 1.7 grams per cubis centimeter and a particle size range of 30 to 125 microns. The filter aid of this invention is capable of being burned with the solids deposited thereon to recover the heat value thereof or to dispose of the solids, is free from silicates or other non-combustible ingredients, and is devoid of fibers which will interfere with the proper operation of the filter unit.

  1. Ceramic fiber reinforced filter

    DOEpatents

    Stinton, David P.; McLaughlin, Jerry C.; Lowden, Richard A.

    1991-01-01

    A filter for removing particulate matter from high temperature flowing fluids, and in particular gases, that is reinforced with ceramic fibers. The filter has a ceramic base fiber material in the form of a fabric, felt, paper of the like, with the refractory fibers thereof coated with a thin layer of a protective and bonding refractory applied by chemical vapor deposition techniques. This coating causes each fiber to be physically joined to adjoining fibers so as to prevent movement of the fibers during use and to increase the strength and toughness of the composite filter. Further, the coating can be selected to minimize any reactions between the constituents of the fluids and the fibers. A description is given of the formation of a composite filter using a felt preform of commercial silicon carbide fibers together with the coating of these fibers with pure silicon carbide. Filter efficiency approaching 100% has been demonstrated with these filters. The fiber base material is alternately made from aluminosilicate fibers, zirconia fibers and alumina fibers. Coating with Al.sub.2 O.sub.3 is also described. Advanced configurations for the composite filter are suggested.

  2. Comparison on the efficacy of everolimus-eluting stent and zotarolimus-eluting stents in coronary heart disease between diabetic and non-diabetic patients

    PubMed Central

    Lin, Liming; Jin, Cheng; Wei, Xiaoming; Li, Huiying; Shi, Jihong; Wu, Shouling; Yang, Xiaojie; Qi, Xiangqian

    2015-01-01

    Objective: The aim of this study is to examine and compare the efficacy of everolimus-eluting stents (EES) and zotarolimus-eluting stents (ZES) in coronary heart disease in diabetic or non-diabetic patients. Methods: A total of 666 patients needed for percutaneous coronary intervention were randomly selected from June 2008 to June 2013 in our hospital and were divided into two groups: (i) coronary heart disease with diabetes group and (ii) non-diabetes group. Patients in each group were further assigned to receive treatment of either EES or ZES. Then we observed the major adverse cardiac events, including mortality, nonfatal myocardial infarction and non-fatal cerebrovascular events over the period of 15 months after initial stent implantation. Results: Compared to the non-diabetic group, more patients in diabetic group had received anti-hypotensive treatment (72% vs. 49%, P < 0.0001) and hypolipemic treatment (80% vs. 67%, P < 0.0001) before the percutaneous coronary intervention. In both diabetic group and non-diabetic group, patients received ZES treatment had a much greater incidence rate of major adverse cardiac events compared to the patients received EES treatment (P < 0.05). Meanwhile, target lesion revascularization rate in the ZES group was also significantly higher than that in the EES group. The data showed big differences between ZES and EES groups with important statistical significance (P < 0.05). Conclusion: Patients with coronary heart disease and diabetes have a higher risk of major adverse cardiac events after stent implantation. EES treatment is safer with higher efficacy in our study, being a more effective stent for the patients merged with diabetes. PMID:26885005

  3. FINAL REPORT. ACTINIDE-ALUMINATE SPECIATION IN ALKALINE RADIOACTIVE WASTE

    EPA Science Inventory

    Investigation of behavior of actinides in alkaline media containing Al(III) showed that no aluminate complexes of actinides in oxidation states (III-VII) were formed in alkaline solutions. At alkaline precipitation (pH 10-14) of actinides in presence of Al(III) formation of alumi...

  4. Solc filter engineering

    NASA Technical Reports Server (NTRS)

    Rosenberg, W. J.; Title, A. M.

    1982-01-01

    A Solc (1965) filter configuration is presented which is both tunable and spectrally variable, since it possesses an adjustable bandwidth, and which although less efficient than a Lyot filter is attractive because of its spectral versatility. The lossless design, using only an entrance and exit polarizer, improves throughput generally and especially in the IR, where polarizers are less convenient than dichroic sheet polarizers. Attention is given to the transmission profiles of Solc filters with different numbers of elements and split elements, as well as their mechanical design features.

  5. Multilevel filtering elliptic preconditioners

    NASA Technical Reports Server (NTRS)

    Kuo, C. C. Jay; Chan, Tony F.; Tong, Charles

    1989-01-01

    A class of preconditioners is presented for elliptic problems built on ideas borrowed from the digital filtering theory and implemented on a multilevel grid structure. They are designed to be both rapidly convergent and highly parallelizable. The digital filtering viewpoint allows the use of filter design techniques for constructing elliptic preconditioners and also provides an alternative framework for understanding several other recently proposed multilevel preconditioners. Numerical results are presented to assess the convergence behavior of the new methods and to compare them with other preconditioners of multilevel type, including the usual multigrid method as preconditioner, the hierarchical basis method and a recent method proposed by Bramble-Pasciak-Xu.

  6. Longer storage of dialyzers increases elution of poly(N-vinyl-2-pyrrolidone) from polysulfone-group dialysis membranes.

    PubMed

    Namekawa, Koki; Kaneko, Ami; Sakai, Kiyotaka; Kunikata, Satoru; Matsuda, Masato

    2011-03-01

    The objective of this study was to evaluate the effect of protracted storage of dialyzers on the amount of poly(N-vinyl-2-pyrrolidone) (PVP) eluted from polysulfone-group dialysis membranes. We tested five dialysis membranes: APS-15SA (Asahi Kasei Kuraray, wet), CX-1.6U (Toray, moist), FX140 (Fresenius, dry), PES-15Sα (Nipro, dry), and FDX-150GW (Nikkiso, wet). Each dialyzer was stored for 1, 3, 14, and 18 months after sterilization. The dialysis-fluid side compartment was primed with reverse osmosis (RO) water at 500 mL/min for 5 min at 310 K. The blood side compartment was primed with RO water at 200 mL/min for 5 min at 310 K. Finally, 1 L RO water was circulated through the blood side compartment at 200 mL/min for 4 h at 310 K. Eluted PVP was determined by use of the iodine method, using 0.02 N: iodine solution. PVP was mainly eluted from wet-type dialyzers during priming. Thus, the standard 5 min priming of the wet-type dialyzer according to the maker manual inhibits PVP elution during circulation. PVP was eluted in the dialysis-fluid side of the moist-type dialyzer during priming but no PVP was eluted in the blood side. PVP was mainly eluted from dry-type dialyzers during circulation. We recommend more than the standard 5 min priming, particularly for dry-type dialyzers stored for protracted periods, because 5 min insufficient to inhibit PVP elution during circulation. PMID:21286768

  7. Poly(N-vinyl-2-pyrrolidone) elution from polysulfone dialysis membranes by varying solvent and wall shear stress.

    PubMed

    Namekawa, Koki; Matsuda, Masato; Fukuda, Makoto; Kaneko, Ami; Sakai, Kiyotaka

    2012-06-01

    Some dialysis patients are treated with post-hemodiafiltration (HDF); the blood viscosity of the patients who undergo post-HDF is higher than that of the patients who undergo conventional hemodialysis. This study aims to evaluate poly(N-vinyl-2-pyrrolidone) (PVP) elution from PSf dialysis membranes by varying solvents and high wall shear stress caused by blood viscosity. We tested three commercial membranes: APS-15SA (Asahi Kasei Kuraray), CX-1.6U (Toray) and FX140 (Fresenius). Dialysate and blood sides of the dialyzers were primed with reverse osmosis (RO) water and saline. RO water, saline and dextran solution (2.9 and 5.8 mPa s) were circulated in the blood side. The amount of eluted PVP was determined by 0.02 N iodometry. The hardness and adsorption force of human serum albumin (HSA) on the membrane surfaces were measured by the atomic force microscope. When wall shear stress was increased using dextran, the amount of PVP eluted by the 2.9 mPa s solution equaled that eluted by the 5.8 mPa s solution with APS-15SA and CX-1.6U sterilized by gamma rays. The amount of PVP eluted by the 5.8 mPa s solution was higher than that eluted by the 2.9 mPa s solution with FX140 sterilized by autoclaving. The wall shear stress increased the PVP elution from the surface, hardness and adsorption force of HSA. Sufficient gamma-ray irradiation is effective in decreasing PVP elution. PMID:22311608

  8. Influence of amount of oxidizing slag discharged from stainless steelmaking process of electric arc furnace on elution behavior into fresh water

    NASA Astrophysics Data System (ADS)

    Yokoyama, S.; Shimomura, T.; Hisyamudin, M. N. N.; Takahashi, T.; Izaki, M.

    2012-03-01

    Fundamental study was carried out for provision for acidification of soil due to acid rain. The influence of weight of the additive slag on elution behavior of the slag into water was studied in this study. Elution experiment was carried out on a basis of JIS K 0058-1. Generally, the pH in the aqueous solution increased with an increase in weight of the additive slag. The pH converged to approximately eight. Calcium, magnesium and manganese, which were essential elements for plants, were eluted from the slag irrespective to elution condition. The eluted concentrations of Ca and Mg increased with an increase in weight of the additive slag. Silicon and zinc were also eluted depending on the conditions. Aluminum that was harmful for plants was not eluted from the used slag.

  9. Comparison of zonal elution and nonlinear chromatography in determination of the interaction between seven drugs and immobilised β(2)-adrenoceptor.

    PubMed

    Li, Qian; Wang, Jing; Zheng, Yuqing Yuan; Yang, Lingjian; Zhang, Yajun; Bian, Liujiao; Zheng, Jianbin; Li, Zijian; Zhao, Xinfeng; Zhang, Youyi

    2015-07-01

    Zonal elution and nonlinear chromatography are two mainstream models for the determination of drug-protein interaction in affinity chromatography. This work intended to compare the results by zonal elution with that by nonlinear chromatography when it comes to the analysis of the interaction between seven drugs and immobilised β2-adrenoceptor (β2-AR). The results of the zonal elution showed that clorprenaline, clenbuterol, methoxyphenamine, salbutamol, terbutaline, tulobuterol and bambuterol have only one type of binding site on immobilised β2-AR, while nonlinear chromatography confirmed the existence of at least two types of binding sites between β2-AR and clorprenaline, clenbuterol and bambuterol. On these sites, both zonal elution and nonlinear chromatography presented the same rank order for the association constants of the seven drugs. Compared with the data from zonal elution, the association constants calculated using nonlinear chromatography gave a good linear response to the corresponding values by radio-ligand binding assay. The sampling efficiencies of nonlinear chromatography were clearly higher than zonal elution. Nonlinear chromatography will probably become a powerful alternative for the high throughput determination of drug-protein interaction. PMID:26002106

  10. Optimization of adenovirus 40 and 41 recovery from tap water using small disk filters.

    PubMed

    McMinn, Brian R

    2013-11-01

    Currently, the U.S. Environmental Protection Agency's Information Collection Rule (ICR) for the primary concentration of viruses from drinking and surface waters uses the 1MDS filter, but a more cost effective option, the NanoCeram® filter, has been shown to recover comparable levels of enterovirus and norovirus from both matrices. In order to achieve the highest viral recoveries, filtration methods require the identification of optimal concentration conditions that are unique for each virus type. This study evaluated the effectiveness of 1MDS and NanoCeram filters in recovering adenovirus (AdV) 40 and 41 from tap water, and optimized two secondary concentration procedures the celite and organic flocculation method. Adjustments in pH were made to both virus elution solutions and sample matrices to determine which resulted in higher virus recovery. Samples were analyzed by quantitative PCR (qPCR) and Most Probable Number (MPN) techniques and AdV recoveries were determined by comparing levels of virus in sample concentrates to that in the initial input. The recovery of adenovirus was highest for samples in unconditioned tap water (pH 8) using the 1MDS filter and celite for secondary concentration. Elution buffer containing 0.1% sodium polyphosphate at pH 10.0 was determined to be most effective overall for both AdV types. Under these conditions, the average recovery for AdV40 and 41 was 49% and 60%, respectively. By optimizing secondary elution steps, AdV recovery from tap water could be improved at least two-fold compared to the currently used methodology. Identification of the optimal concentration conditions for human AdV (HAdV) is important for timely and sensitive detection of these viruses from both surface and drinking waters. PMID:23796954

  11. Photolysis of alkaline-earth nitrates

    NASA Astrophysics Data System (ADS)

    Kriger, L. D.; Miklin, M. B.; Dyagileva, E. P.; Anan'ev, V. A.

    2013-02-01

    Peroxynitrite and nitrite ions are the diamagnetic products of photolysis (with light at a wavelength of 253.7 nm) of alkaline-earth nitrates; the paramagnetic products and hydrogen peroxide were not found. The structural water in alkaline-earth nitrate crystals did not affect the qualitative composition of the photodecomposition products. The quantum yield of nitrite ions was 0.0012, 0.0038, 0.0078, and 0.0091 quanta-1 and that of peroxynitrite ions was 0.0070, 0.0107, 0.0286, and 0.0407 quanta-1 for Sr(NO3)2, Ba(NO3)2, Ca(NO3)2 · 4H2O, and Mg(NO3)2 · 6H2O, respectively.

  12. Parallel Subconvolution Filtering Architectures

    NASA Technical Reports Server (NTRS)

    Gray, Andrew A.

    2003-01-01

    These architectures are based on methods of vector processing and the discrete-Fourier-transform/inverse-discrete- Fourier-transform (DFT-IDFT) overlap-and-save method, combined with time-block separation of digital filters into frequency-domain subfilters implemented by use of sub-convolutions. The parallel-processing method implemented in these architectures enables the use of relatively small DFT-IDFT pairs, while filter tap lengths are theoretically unlimited. The size of a DFT-IDFT pair is determined by the desired reduction in processing rate, rather than on the order of the filter that one seeks to implement. The emphasis in this report is on those aspects of the underlying theory and design rules that promote computational efficiency, parallel processing at reduced data rates, and simplification of the designs of very-large-scale integrated (VLSI) circuits needed to implement high-order filters and correlators.

  13. Improved optical filter

    NASA Technical Reports Server (NTRS)

    Title, A. M.

    1978-01-01

    Filter includes partial polarizer between birefrigent elements. Plastic film on partial polarizer compensates for any polarization rotation by partial polarizer. Two quarter-wave plates change incident, linearly polarized light into elliptically polarized light.

  14. Westinghouse filter update

    SciTech Connect

    Lippert, T.E.; Bruck, G.J.; Smeltzer, E.E.; Newby, R.A.; Bachovchin, D.M.

    1993-09-01

    Hot gas filters have been implemented and operated in four different test facilities: Subpilot scale entrained gasifier, located at the Texaco Montebello Research facilities in California, Foster Wheeler Advanced Pressurized Fluidized Bed Combustion pilot plant facilities, located in Livingston, New Jersey, Slipstream of the American Electric Power (AEP) 70 MW (electric) Tidd-PFBC, located in Brilliant, Ohio, and in the Ahlstrom 10 MW (thermal) Circulating PFBC facility, located in Karhula, Finland. Candle filter testing has occurred at all four facilities; cross flow filter testing has occurred at the Texaco and Foster Wheeler facilities. Table 1 identifies and summarizes the key operating characteristics of these facilities and the type and scale of filter unit tested. A brief description of each project is given.

  15. Active-R filter

    DOEpatents

    Soderstrand, Michael A.

    1976-01-01

    An operational amplifier-type active filter in which the only capacitor in the circuit is the compensating capacitance of the operational amplifiers, the various feedback and coupling elements being essentially solely resistive.

  16. HEPA air filter (image)

    MedlinePlus

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  17. Alkaline earth cation extraction from acid solution

    DOEpatents

    Dietz, Mark; Horwitz, E. Philip

    2003-01-01

    An extractant medium for extracting alkaline earth cations from an aqueous acidic sample solution is described as are a method and apparatus for using the same. The separation medium is free of diluent, free-flowing and particulate, and comprises a Crown ether that is a 4,4'(5')[C.sub.4 -C.sub.8 -alkylcyclohexano]18-Crown-6 dispersed on an inert substrate material.

  18. The alkaline earth intercalates of molybdenum disulfide

    NASA Technical Reports Server (NTRS)

    Somoano, R. B.; Hadek, V.; Rembaum, A.; Samson, S.; Woollam, J. A.

    1975-01-01

    Molybdenum disulfide has been intercalated with calcium and strontium by means of the liquid ammonia technique. Chemical, X-ray, and superconductivity data are presented. The X-ray data reveal a lowering of crystal symmetry and increase of complexity of the structure upon intercalation with the alkaline earth metals. The Ca and Sr intercalates start to superconduct at 4 and 5.6 K, respectively, and show considerable anisotropy regarding the critical magnetic field.

  19. Surfactant-enhanced alkaline flooding field project

    SciTech Connect

    French, T.R.

    1991-10-01

    The Tucker sand of Helper (KS) field is a candidate for surfactant-enhanced alkaline flooding. The geology of the Helper site is typical of many DOE Class I reservoirs. The Tucker sand of Helper field was deposited in a fluvial dominated deltaic environment. Helper oil can be mobilized with either chemical system 2 or chemical system 3, as described in this report. Oil fields in the Gulf Coast region are also good candidates for surfactant-enhanced alkaline flooding. The results from laboratory tests conducted in Berea sandstone cores with oil brine from Helper (KS) field are encouraging. The crude oil is viscous and non-acidic and, yet, was mobilized by the chemical formulations described in this report. Significant amounts of the oil were mobilized under simulated reservoir conditions. The results in Berea sandstone cores were encouraging and should be verified by tests with field core. Consumption of alkali, measured with field core, was very low. Surfactant loss appeared to be acceptable. Despite the good potential for mobilization of Helper oil, certain reservoir characteristics such as low permeability, compartmentalization, and shallow depth place constraints on applications of any chemical system in the Tucker sand. These constraints are typical of many DOE Class I reservoirs. Although Hepler field is not a perfect reservoir in which to apply surfactant- enhanced alkaline flooding, Hepler oil is particularly amenable to mobilization by surfactant-enhanced alkaline systems. A field test is recommended, dependent upon final evaluation of well logs and cores from the proposed pilot area. 14 refs., 21 figs., 10 tabs.

  20. Anti-Glare Filters

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Glare from CRT screens has been blamed for blurred vision, eyestrain, headaches, etc. Optical Coating Laboratory, Inc. (OCLI) manufactures a coating to reduce glare which was used to coat the windows on the Gemini and Apollo spacecraft. In addition, OCLI offers anti-glare filters (Glare Guard) utilizing the same thin film coating technology. The coating minimizes brightness, provides enhanced contrast and improves readability. The filters are OCLI's first consumer product.

  1. Switching power supply filter

    NASA Technical Reports Server (NTRS)

    Kumar, Prithvi R. (Inventor); Abare, Wayne (Inventor)

    1989-01-01

    A filter for a switching power supply. The filter includes a common mode inductor with coil configurations allowing differential mode current from a dc source to pass through but attenuating common mode noise from the power supply so that the noise does not reach the dc source. The invention also includes the use of feed through capacitors at the switching power supply input terminals to provide further high-frequency noise attenuation.

  2. Alkaline injection for enhanced oil recovery: a status report

    SciTech Connect

    Mayer, E.H.; Berg, R.L.; Carmichael, J.D.; Weinbrandt, R.M.

    1983-01-01

    In the past several years, there has been renewed interest in enhanced oil recovery (EOR) by alkaline injection. Alkaline solutions also are being used as preflushes in micellar/polymer projects. Several major field tests of alkaline flooding are planned, are in progress, or recently have been completed. Considerable basic research on alkaline injection has been published recently, and more is in progress. This paper summarizes known field tests and, where available, the amount of alkali injected and the performance results. Recent laboratory work, much sponsored by the U.S. DOE, and the findings are described. Alkaline flood field test plans for new projects are summarized.

  3. Alkaline flooding for enhanced oil recovery

    SciTech Connect

    Gittler, W.E.

    1983-09-01

    There are over 12 active projects of varying size using one of 3 major types of alkaline agents. These include sodium silicate, caustic soda, and soda ash. Among the largest pilots currently is the THUMS project in the Wilmington field, California. Plans called for the injection of a 4% weight concentration of sodium orthosilicate over a 60% PV. Through the first 3 yr, over 27 million bbl of chemicals have been injected. Gulf Oil is operating several alkaline floods, one of which is located off shore in the Quarantine Bay field, Louisiana. In this pilot, sodium hydroxide in a weight concentration of 5 to 12% is being injected. Belco Petroleum Corp. has reported that their pilot operating in the Isenhour Unit in Wyoming is using a .5% weight concentration of soda ash in conjunction with a polymer. Other uses for alkaline agents in chemical flooding include the use of silicate as a preflush or sacrificial agent in micellar/polymer and surfactant recovery systems. In addition, caustic has been tested in the surface-mixed caustic emulsion process while orthosilicate has been tested in a recovery method known as mobility-controlled caustic floods.

  4. Contactor/filter improvements

    DOEpatents

    Stelman, David

    1989-01-01

    A contactor/filter arrangement for removing particulate contaminants from a gaseous stream includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. The housing further includes a gas inlet means, a gas outlet means, and means for moving a body of granular material through the zone. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. Disposed on the upstream face of the filter element is a cover screen which isolates the filter element from contact with the moving granular bed and collects a portion of the particulates so as to form a dust cake having openings small enough to exclude the granular material, yet large enough to receive the dust particles. In one embodiment, the granular material is comprised of prous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses.

  5. Remotely serviced filter and housing

    DOEpatents

    Ross, Maurice J.; Zaladonis, Larry A.

    1988-09-27

    A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge using an overhead crane. The filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station.

  6. The fate of added alkalinity in model scenarios of ocean alkalinization

    NASA Astrophysics Data System (ADS)

    Ferrer González, Miriam; Ilyina, Tatiana

    2014-05-01

    The deliberate large-scale manipulation of the Earth's climate (geo-engineering) has been proposed to mitigate climate change and ocean acidification. Whilst the mitigation potential of these technologies could sound promising, they may also pose many environmental risks. Our research aims at exploring the ocean-based carbon dioxide removal method of alkalinity enhancement. Its mitigation potential to reduce atmospheric CO2 and counteract the consequences of ocean acidification, risks and unintended consequences are studied. In order to tackle these questions, different scenarios are implemented in the state-of-the-art Earth system model of the Max Planck Institute for Meteorology. The model configuration is based on the 5th phase of the coupled model intercomparison project following a high CO2 future climate change scenario RCP8.5 (in which radiative forcing rises to 8.5 W/m² in 2100). Two different scenarios are performed where the alkalinity is artificially added globally uniformly in the upper ocean. In the first scenario, alkalinity is increased as a pulse by doubling natural values of the first 12 meters. In the second scenario we add alkalinity into the same ocean layer such that the atmospheric CO2 concentration is reduced from RCP8.5 to RCP4.5 levels (with the radiative forcing of 4.5 W/m² in 2100). We investigate the fate of the added alkalinity in these two scenarios and compare the differences in alkalinity budgets. In order to increase oceanic CO2 uptake from the atmosphere, enhanced alkalinity has to stay in the upper ocean. Once the alkalinity is added, it will become part of the biogeochemical cycles and it will be distributed with the ocean currents. Therefore, we are particularly interested in the residence time of the added alkalinity at the surface. Variations in CO2 partial pressure, seawater pH and saturation state of carbonate minerals produced in the implemented scenarios will be presented. Collateral changes in ocean biogeochemistry and

  7. Cochlear implant and inflammation reaction: Safety study of a new steroid-eluting electrode.

    PubMed

    Astolfi, L; Simoni, E; Giarbini, N; Giordano, P; Pannella, M; Hatzopoulos, S; Martini, A

    2016-06-01

    Dexamethasone is a common anti-inflammatory agent added to cochlear implants to reduce hearing loss due to electrode insertion trauma. We evaluated the safety of eluting silicone rods containing 10% dexamethasone in a Guinea pig model. Animals were implanted with a dexamethasone eluting silicone electrode (DER) or with a non-eluting electrode (NER). The control group only underwent a cochleostomy (CS). Prior to implantation and during the two weeks following implantation, the hearing status of the animals was assessed by means of Compound Action Potentials (CAPs) with an electrode placed near the round window. Two weeks after implantation, the mean click threshold shifts were 1 dB ± 10 dB in the DER group, 10 dB ± 10 dB in the NER group and -4 dB ± 10 dB in the control group. After two weeks the bullae of each animal were extracted to verify the presence of macrophages, the percent of tissue growth in the scala tympani and the tissue sealing around cochleostomy. Silicone electrodes samples were also explanted and examined for bacterial infection. Neither bacterial infection nor enhanced number of macrophages were observed. A limited, but not significant, tissue growth was found in the scala tympani between the experimental and the control group. The data suggest that, in the Guinea pig model, the use of DER is apparently safe as an anti-inflammatory slow-release additive to the cochlear implant. PMID:27109196

  8. Retention prediction and separation optimization under multilinear gradient elution in liquid chromatography with Microsoft Excel macros.

    PubMed

    Fasoula, S; Zisi, Ch; Gika, H; Pappa-Louisi, A; Nikitas, P

    2015-05-22

    A package of Excel VBA macros have been developed for modeling multilinear gradient retention data obtained in single or double gradient elution mode by changing organic modifier(s) content and/or eluent pH. For this purpose, ten chromatographic models were used and four methods were adopted for their application. The methods were based on (a) the analytical expression of the retention time, provided that this expression is available, (b) the retention times estimated using the Nikitas-Pappa approach, (c) the stepwise approximation, and (d) a simple numerical approximation involving the trapezoid rule for integration of the fundamental equation for gradient elution. For all these methods, Excel VBA macros have been written and implemented using two different platforms; the fitting and the optimization platform. The fitting platform calculates not only the adjustable parameters of the chromatographic models, but also the significance of these parameters and furthermore predicts the analyte elution times. The optimization platform determines the gradient conditions that lead to the optimum separation of a mixture of analytes by using the Solver evolutionary mode, provided that proper constraints are set in order to obtain the optimum gradient profile in the minimum gradient time. The performance of the two platforms was tested using experimental and artificial data. It was found that using the proposed spreadsheets, fitting, prediction, and optimization can be performed easily and effectively under all conditions. Overall, the best performance is exhibited by the analytical and Nikitas-Pappa's methods, although the former cannot be used under all circumstances. PMID:25869801

  9. Antibiotic eluting clay mineral (Laponite®) for wound healing application: an in vitro study.

    PubMed

    Ghadiri, M; Chrzanowski, W; Rohanizadeh, R

    2014-11-01

    Different materials in form of sponge, hydrogel and film have been developed and formulated for treating and dressing burn wounds. In this study, the potential of Laponite, a gel forming clay, in combination with an antimicrobial agent (mafenide), as a wound dressing material was tested in vitro. Laponite/mafenide (Lap/Maf) hydrogel was formulated in three different ratios of Lap/Maf 1:1, 1:2, 1:3. Laponite/mafenide/alginate (Lap/Maf/Alg) film was also formulated by combining Lap/Maf gel (1:1) with alginate. Intercalation rate of mafenide into the layers of Laponite nanoparticles and physico-chemical properties, including wound dressing characteristics of materials were studied using various analytical methods. Furthermore, the degradation of materials and the release profile of mafenide were investigated in simulated wound exudates fluid and antibacterial effectiveness of the eluted mafenide was tested on a range of bacterial species. The cytotoxicity of materials was also evaluated in skin fibroblast culture. The results showed that mafenide molecules were intercalated between the nano-sized layers of Laponite. The eluted mafenide showed active antibacterial effects against all three tested bacteria. All intercalated mafenide released from Lap/Maf 1:1 and 1:2 gel formulations and nearly 80% release from 1:3 formulation during test period. No significant difference was observed in release profile of mafenide between Lap/Maf/Alg film and Lap/Maf formulations. Wound dressing tests on Lap/Maf/Alg film showed it is a breathable dressing and has capacity to absorb wound exudates. The study showed that prepared Lap/Maf composite has the potential to be used as an antibiotic eluting gel or film for wound healing application. Additionally, Laponite has shown benefits in wound healing processes by releasing Mg(2+) ions and thereby reducing the cytotoxic effect of mafenide on fibroblast cells. PMID:25027303

  10. Simple automated generation of gradient elution conditions in sequential injection chromatography using monolithic column.

    PubMed

    Koblová, Petra; Sklenářová, Hana; Chocholouš, Petr; Polášek, Miroslav; Solich, Petr

    2011-06-15

    The paper deals with the concept of simple automated creation of gradient profile of the mobile phase for gradient-elution sequential injection chromatography (GE-SIC). The feasibility and merits of this concept are demonstrated on the separation and simultaneous assay of indomethacin as active principle and of its two degradation products (5-methoxy-2-methylindoleacetic acid and 4-chloro-benzoic acid) in a topical pharmaceutical formulation. The GE-SIC separation was performed with a FIAlab(®) 3000 SIC set-up (USA) equipped with an Onyx™ Monolithic C18 (25 mm × 4.6mm, Phenomenex(®)) column, a six-port selection valve, a 5-mL syringe pump and a fiber-optics UV CCD detector. Ketoprofen was used as an internal standard (IS). The gradient elution was achieved by automated reproducible mixing of acetonitrile and aqueous 0.2% phosphoric acid in the holding coil of the SIC system. Different profiles of the gradient elution were tested. The optimal gradient using two mobile phases 30:70 and 50:50 of acetonitrile/0.2% phosphoric acid (v/v) was achieved under the optimum flow rate 1.2 mL min(-1). The chromatographic resolution R between the peaks of all solutes (including the IS) was >2.00. The repeatability of retention times was characterized by the RSD values 0.18-0.30% (n=6). Net separation time was 3.5 min and the mobile phase consumption was 4.5 mL for a single GE-SIC assay. The figures of merit of the novel GE-SIC method compared well with those of conventional HPLC. PMID:21641437

  11. Quantitation of specific proteins in polyacrylamide gels by the elution of Fast Green FCF.

    PubMed

    Gilmore, L B; Hook, G E

    1981-07-01

    The quantitation of proteins in polyacrylamide gels stained with Fast green FCF has been investigated using a modification of the elution technique originally described by Fenner et al. (Fenner, C., Traut, R.R., Mason, D.T. and Wikman-Coffelt, J. (1975) Anal. Biochem. 63, 595--602) for Coomassie Blue and adapted by Medugorac (Medugorac, I. (1979) Basic Res. Cardiol. 74, 406--416) for use with proteins stained with Fast Green FCF. The elution of dye from stained protein was accomplished using 1.0 M NaOH instead of aqueous pyridine as required by the original method. The primary advantages of our modification are that the time required for protein quantitation has been considerably reduced and the use of toxic organic solvents has been eliminated. We have investigated the applicability of the method of several different proteins and our results indicate: (a) The quantity of Fast Green FCF eluted from specific proteins is proportional to the quantity of protein applied to the gel, but varies for each individual protein. (b) The method allows quantitation over a very wide range of protein (1--800 micrograms). (c) Quantitation of protein is independent of the width of the stained bands as well as acrylamide concentration. (d) The method is applicable to gels of many types including disc, slab and continuous gradient gels. (e) Protein can be estimated from the patterns obtained by two-dimensional polyacrylamide gel electrophoresis. (f) The presence of Triton X-100 in gel and protein sample does not affect quantitation; the method is applicable to gels containing SDS provided that SDS is removed prior to staining. (g) Precipitation of protein with 12.5% TCA following electrophoresis does not interfere with quantitation. (h) The reproducibility of the technique is excellent, with standard deviations being less than 10% of the mean in all cases. This method appears highly versatile but requires appropriate standards for the quantitation of individual proteins. PMID:7276424

  12. Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits

    PubMed Central

    Ruiter, Matthijs S.; van Tiel, Claudia M.; Doornbos, Albert; Marinković, Goran; Strang, Aart C.; Attevelt, Nico J. M.; de Waard, Vivian; de Winter, Robbert J.; Steendam, Rob; de Vries, Carlie J. M.

    2015-01-01

    Background The introduction of drug-eluting stents (DES) has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP) has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC), endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface. Methods Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions. Results Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation. Conclusion We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient. PMID:26389595

  13. Impact of Statin Treatment on Strut Coverage after Drug-Eluting Stent Implantation

    PubMed Central

    Suh, Yongsung; Kim, Byeong-Keuk; Shin, Dong-Ho; Kim, Jung-Sun; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo

    2015-01-01

    Purpose To evaluate the effect of statin treatment on strut coverage after drug-eluting stent (DES) implantation. Materials and Methods In this study, 60 patients were randomly assigned to undergo sirolimus-eluting stent (SES) or biolimus-eluting stent (BES) implantation, after which patients were randomly treated with pitavastatin 2 mg or pravastatin 20 mg for 6 months. The degree of strut coverage was assessed by 6-month follow-up optical coherence tomography, which was performed in 52 DES-implanted patients. Results The percentages of uncovered struts were 19.4±14.7% in pitavastatin-treated patients (n=25) and 19.1±15.2% in pravastatin-treated patients (n=27; p=0.927). A lower percentage of uncovered struts was significantly correlated with a lower follow-up low-density lipoprotein (LDL) cholesterol level (r=0.486; p=0.009) and a greater decline of the LDL cholesterol level (r=-0.456; p=0.015) in SES-implanted patients, but not in BES-implanted patients. In SES-implanted patients, the percentage of uncovered struts was significantly lower among those with LDL cholesterol levels of less than 70 mg/dL after 6 months of follow-up (p=0.025), but no significant difference in this variable according to the follow-up LDL cholesterol level was noted among BES-implanted patients (p=0.971). Conclusion Lower follow-up LDL cholesterol levels, especially those less than 70 mg/dL, might have a protective effect against delayed strut coverage after DES implantation. This vascular healing effect of lower LDL cholesterol levels could differ according to the DES type. PMID:25510746

  14. Miniaturized Self-Expanding Drug-Eluting Stent in Small Coronary Arteries: Late Effectiveness

    PubMed Central

    de Oliveira, Flavio Roberto Azevedo; Mattos, Luiz Alberto Piva e; Abizaid, Alexandre; Abizaid, Andrea S.; Costa, J. Ribamar; Costa, Ricardo; Staico, Rodolfo; Botelho, Roberto; Sousa, J. Eduardo; Sousa, Amanda

    2013-01-01

    Background Small vessels represent a risk factor for restenosis in percutaneous coronary angioplasty (PCA). The Sparrow® self-expanding drug-eluting stent, which has a lower profile than the current systems, has never been tested in this scenario. Objectives To evaluate the late effectiveness of the Sparrow® drug-eluting stent, regarding in-stent late lumen loss (LLL). Methods Patients with ischemia, symptomatic or documented, were submitted to PCA in vessels with reference diameter < 2.75 mm, divided into two groups regarding Sparrow® stent type: group 1: Sparrow® drug-eluting stent (DES), group 2: Sparrow® bare metal stent (BMS). Clinical follow-up duration was 12 months. Evaluation using quantitative coronary angiography (QCA) was performed immediately and at 8 months. A decrease of over 65% of in-stent LLL with DES was estimated to calculate sample size. IBM® SPSS software, release 19 (Chicago, Illinois, USA) was used for the statistical analysis. Results A total of 24 patients were randomized, 12 in each group. The DES and BMS groups were similar in age (63.25 ± 10.01 vs. 64.58 ± 11.54, p = 0.765), male gender (58.3% vs. 33.3%, p = 0.412), risk factors and all angiographs aspects. Immediate results were satisfactory in both groups. At 8 months in-stent late lumen loss was significantly lower in DES than in BMS group (DES vs. BMS 0.25 ± 0.16 0.97 ± 0.76, p = 0.008). Conclusion In small-vessel PCA, the Sparrow® DES determined significant reduction in in-stent LLL, when compared to Sparrow® BMS. PMID:24100691

  15. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    PubMed Central

    da Silva, Rose Mary Ferreira Lisboa; Silva, Carlos Augusto Bueno; Greco, Otaviano José; Moreira, Maria da Consolação Vieira

    2014-01-01

    Background The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents. PMID:25029473

  16. Vasculitis resulting from a superficial femoral artery angioplasty with a paclitaxel-eluting balloon.

    PubMed

    Thomas, Shannon D; McDonald, Robert R A; Varcoe, Ramon L

    2014-02-01

    Drug-eluting balloons (DEBs) coated with the antiproliferative agent paclitaxel may improve primary patency by reducing recurrent luminal stenosis. A proportion of the active drug and excipient coating are known to embolize distally, but until now, there have been no reports of adverse events resulting from their use. We report an unusual case of a painful nodular, biopsy specimen-proven vasculitic rash that afflicted the ipsilateral lower limb of a patient after superficial femoral artery treatment with a DEB. This adverse event may have implications for the use of DEB in this and other vascular territories. PMID:23642919

  17. Acute ischemic cholecystitis after transarterial chemoembolization with drug-eluting beads.

    PubMed

    Karaman, Bülent; Battal, Bilal; Ören, Nisa Cem; Üstünsöz, Bahri; Yağci, Gökhan

    2012-01-01

    Transarterial chemoembolization (TACE) is a widely used treatment choice for hepatocellular cancer. DC Bead microspheres are a new embolic material for TACE that doxorubicin can be loaded to. The tumor response rate of this well-tolerated treatment was changed between 60% and 81.8%. We report a case of ischemic cholecystitis after TACE with drug-eluting beads (DEB) that required cholecystectomy. The possibility of cholecystitis is always remembered during TACE-DEB for tumors in segment IV and/or V. Although selective catheterization is related with a lower risk for ischemic cholecystitis, the anatomic and vascular variability in patients with malignancy may lead to some unexpected conditions. PMID:23154025

  18. Solid phase extraction and HPLC analysis of toxic components eluted from methyl methacrylate dental materials.

    PubMed

    Shintani, H; Tsuchiya, T; Hata, Y; Nakamura, A

    1993-01-01

    Methyl methacrylate polymer (PolyMMA) is widely used as the composite resin for the dental plate. During the fabrication process of PolyMMA for the polymerization reaction, benzoylperoxide (BPO) and N,N-dimethyl p-toluidine (DMPT) are added as the initiator and the stimulator, respectively. Because these compounds exhibit toxicity as well as a residue potential, their use raises concerns regarding human safety. The degree of dissolution into serum was determined to evaluate risk to the user. Analysis was by HPLC combined with solid-phase extraction using a C-18 column. The eluted compounds were found to be in the order of 10 to 100 ppm. PMID:8492570

  19. Bradycardia Associated With Drug-Eluting Beads Loaded With Irinotecan (DEBIRI) Infusion for Colorectal Liver Metastases

    SciTech Connect

    Pua, Uei

    2013-06-15

    Intra-arterial injection of drug-eluting beads loaded with irinotecan (DEBIRI) is a new treatment option being investigated, with encouraging results, for unresectable colorectal liver metastases that are refractory to systemic chemotherapy (Martin et al., Ann Surg Oncol 18:192-198, 2011). Toxicity related to DEBIRI has also been described (Martin et al., Cardiovasc Intervent Radiol 33:960-966, 2010). Nevertheless, experience and literature related to DEBIRI remain limited, and experience with this treatment is expected to increase. The purpose of this article is to describe bradycardia occurring during DEBIRI administration, which has not been reported thus far.

  20. Optimization of hydrophobic interaction chromatography using a mathematical model of elution curves of a protein mixture.

    PubMed

    Lienqueo, María Elena; Shene, Carolina; Asenjo, Juan

    2009-01-01

    This paper describes a methodology for optimizing performance of hydrophobic interaction chromatography (HIC) for protein mixtures in which Rate Model simulations and evaluation of cost function are used. The system under study was HIC of a two-protein mixture (alpha-chymotrypsin and alpha-amylase), carried out with different conditions (gradient steepness, salt, concentration, volume of sample, pH, type of matrix, and flow rates). Parameters in the rate model were obtained from different sources. Mass transfer parameters (Reynolds, Peclet, and Biot numbers) were calculated using empirical correlations. Under the experimental conditions Re number was small (0.23) and axial dispersion negligible (PeL>300). Mass transfer was controlled by intraparticle diffusion (Bi>50). The model assumes that equilibrium constant (b) in the Langmuir isotherm was salt concentration (I) dependent [b(I)]. Parameters in the relationship for b(I) were estimated from experimental single protein elution curves and used to simulate protein mixtures. Rate model simulations showed that if protein sample load to the column was below 1 mg, displacement effects were negligible; in other cases protein interactions would limit the proposed mathematical description of HIC. The calibrated Rate Model successfully predicted elution curves of the protein mixture with deviations lower than 6x10(-4) absorbance units. The model was also able to predict that the Butyl Sepharose--NaCl 4 M system allowed to obtain the highest resolution (>1) for the two-protein mixture evaluated. The cost function built for optimizing the performance of HIC considers yield, purity, concentration, and the time needed to accomplish the separation. This function contains two types of parameters that have to be determined. The ones dependent on the HIC system and process conditions were obtained from simulations of elution curves of the two-protein mixture, by the calibrated Rate Model. The other parameters are dependent on

  1. Strontium eluting graphene hybrid nanoparticles augment osteogenesis in a 3D tissue scaffold

    NASA Astrophysics Data System (ADS)

    Kumar, Sachin; Chatterjee, Kaushik

    2015-01-01

    The objective of this work was to prepare hybrid nanoparticles of graphene sheets decorated with strontium metallic nanoparticles and demonstrate their advantages in bone tissue engineering. Strontium-decorated reduced graphene oxide (RGO_Sr) hybrid nanoparticles were synthesized by the facile reduction of graphene oxide and strontium nitrate. X-ray diffraction, transmission electron microscopy, and atomic force microscopy revealed that the hybrid particles were composed of RGO sheets decorated with 200-300 nm metallic strontium particles. Thermal gravimetric analysis further confirmed the composition of the hybrid particles as 22 wt% of strontium. Macroporous tissue scaffolds were prepared by incorporating RGO_Sr particles in poly(ε-caprolactone) (PCL). The PCL/RGO_Sr scaffolds were found to elute strontium ions in aqueous medium. Osteoblast proliferation and differentiation was significantly higher in the PCL scaffolds containing the RGO_Sr particles in contrast to neat PCL and PCL/RGO scaffolds. The increased biological activity can be attributed to the release of strontium ions from the hybrid nanoparticles. This study demonstrates that composites prepared using hybrid nanoparticles that elute strontium ions can be used to prepare multifunctional scaffolds with good mechanical and osteoinductive properties. These findings have important implications for designing the next generation of biomaterials for use in tissue regeneration.The objective of this work was to prepare hybrid nanoparticles of graphene sheets decorated with strontium metallic nanoparticles and demonstrate their advantages in bone tissue engineering. Strontium-decorated reduced graphene oxide (RGO_Sr) hybrid nanoparticles were synthesized by the facile reduction of graphene oxide and strontium nitrate. X-ray diffraction, transmission electron microscopy, and atomic force microscopy revealed that the hybrid particles were composed of RGO sheets decorated with 200-300 nm metallic strontium

  2. Economic analysis of endovascular drug-eluting treatments for femoropopliteal artery disease in the UK

    PubMed Central

    Katsanos, Konstantinos; Garner, Abigail M; Zayed, Hany; Cleveland, Trevor; Pietzsch, Jan B

    2016-01-01

    Objectives To estimate the clinical and economic impact of drug-eluting endovascular treatment strategies for femoropopliteal artery disease compared with current standard of care. Design Systematic literature search to pool target lesion revascularisations (TLR). Model-based per-patient cost impact and quasi-cost-effectiveness projection over 24 months based on pooled TLRs and current reimbursement. Setting The UK's National Health Service (NHS). Participants Patients presenting with symptomatic femoropopliteal disease eligible for endovascular treatment. Interventions Current National Institute for Health and Care Excellence (NICE) guideline-recommended treatment with percutaneous transluminal balloon angioplasty (PTA) and bailout bare metal stenting (BMS) versus primary BMS placement, or drug-coated balloon (DCB), or drug-eluting stent (DES) treatment. Primary and secondary outcome measures 24-month per-patient cost impact to NHS (primary outcome). Secondary outcomes: pooled 24-month TLR rates; numbers needed to treat (NNTs); cost per TLR avoided and estimated incremental cost-effectiveness ratio (ICER) in £ per quality-adjusted life year (QALY). Results N=28 studies were identified, reporting on 5167 femoropopliteal lesions. Over 24 months, DCB, DES and BMS reduced TLRs of de novo lesions from 36.2% to 17.6%, 19.4% and 26.9%, respectively, at an increased cost of £43, £44 and £112. NNTs to avoid 1 TLR in 24 months were 5.4, 6.0 and 10.8, resulting in cost per TLR avoided of £231, £264 and £1204. DCB was estimated to add 0.011 QALYs, DES 0.010 QALYs and BMS 0.005 QALYs, resulting in estimated ICERs of £3983, £4534 and £20 719 per QALY gained. A subset analysis revealed more favourable clinical and economic outcomes for a 3.5 µg/mm2 DCB with urea excipient, compared with the rest of DCBs. A modest reduction of 10% in DCB and DES prices made drug-eluting treatments dominant. Conclusions Widespread adoption of drug-eluting endovascular

  3. Sirolimus-eluting stent fracture detection by three-dimensional optical coherence tomography.

    PubMed

    Okamura, Takayuki; Matsuzaki, Masunori

    2012-03-01

    Stent fracture has emerged as a complication of drug-eluting stent and is now recognized as contributing to in-stent restenosis and possibly stent thrombosis. Although optical coherence tomography (OCT) can detect stent fractures in the absence of circumference struts, it is challenging to visualize stent fractures with only cross-sectional OCT images. We describe two cases of restenosis with stent fracture detected by a novel three-dimensional OCT image reconstruction technique. This technique allows identification of a single stent fracture even in the absence of angiographic signs. PMID:21805594

  4. Liquid chromatography at critical conditions in ternary mobile phases: gradient elution along the critical line.

    PubMed

    Trathnigg, Bernd; Malik, Muhammad Imran; Pircher, Nicole; Hayden, Stephan

    2010-07-01

    In ternary mobile phases consisting of acetone, methanol, and water, the retention of PEG on reversed-phase columns is independent on molar mass at certain compositions of the mobile phase. Along this critical adsorption line, the retention of polypropylene glycol varies quite strongly, which can be utilized in the separation of block copolymers. Gradient elution along the critical line allows a baseline separation of all oligomers in polypropylene glycol up to approximately 25 propylene oxide units. The same resolution can be achieved in the separation of ethylene oxide-propylene oxide block copolymers, regardless of the length of the ethylene oxide block. PMID:20535754

  5. Adenosine-induced coronary vasospasm following drug-eluting stent implantation

    PubMed Central

    Matsumoto, Naoya; Nagao, Ken; Hirayama, Atsushi; Kasama, Shu

    2014-01-01

    We present the case of coronary vasospasm during adenosine stress in a patient with a prior drug-eluting stent implantation. The patient had a stent implantation in the left anterior descending coronary artery 3 years ago. Recently, he developed a chest pain and underwent adenosine stress myocardial perfusion single photon emission CT (SPECT). During the adenosine stress, he felt severe chest pain and ST elevation on electrocardiogram. An invasive coronary angiography showed no in-stent restenosis. This phenomenon deemed to be adenosine-induced coronary vasospasm after stent implantation. PMID:24518394

  6. Application of rotational atherectomy in the drug-eluting stent era

    PubMed Central

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  7. In-filter PCDF and PCDD formation at low temperature during MSWI combustion.

    PubMed

    Weidemann, Eva; Marklund, Stellan; Bristav, Henrik; Lundin, Lisa

    2014-05-01

    This case study investigated PCDF and PCDD emissions from a 65 MW waste-to-energy plant to identify why an air pollution control system remodeling to accommodate increased production resulted in increased TEQ concentrations. Pre- and post-filter gases were collected simultaneously in four sample sets with varying filter temperatures and with/without activated carbon injection. Samples were analyzed to determine total PCDF and PCDD concentrations, as well as homologue profiles, and concentrations of individual congeners (some remained co-eluted). The total post filter PCDD concentrations where found to increase while the concentrations of PCDF and 2,3,7,8-substituted congeners declined. An investigation of the individual congener concentrations revealed that the increase of PCDD concentrations were due to a few congeners, suggesting a single formation route. The study also concludes that vital information about the formation could be obtained by not restricting the analysis to just the 2,3,7,8-substituted congeners. PMID:24359919

  8. Filter and method of fabricating

    DOEpatents

    Janney, Mark A.

    2006-02-14

    A method of making a filter includes the steps of: providing a substrate having a porous surface; applying to the porous surface a coating of dry powder comprising particles to form a filter preform; and heating the filter preform to bind the substrate and the particles together to form a filter.

  9. Sequential leaching of coal to investigate the elution of inorganic elements into coal extract (HyperCoal)

    SciTech Connect

    Lian Zhang; Toshimasa Takanohashi; Tetsuya Nakazato; Ikuo Saito; Hiroaki Tao

    2008-07-15

    Two Argonne premium coal samples, Illinois No. 6 (IL) and Wyodak-Anderson (WY), were extracted by 1-methynaphthalene for 1 h at 360{sup o}C and under 1 MPa nitrogen (cold) protection. Elution of inorganic elements into coal extracts as well as their chemistry has been mainly investigated. An indirect method for metallic speciation was employed by initially washing coal with a variety of acids. Subsequently, the washed coals as well as the respective raw coal were extracted. For a given metal, elution of its ion-exchangeable fraction was defined as the difference between its amounts eluted into the extracts of raw coal and acetic acid-washed coal. Elution of submicrometer discrete particles was defined as the difference between the extracts of acetic acid-washed coal and nitric acid-washed coal. Elution of its fraction insoluble in nitric acid was assigned as organometals which are chemically associated with coal carbonaceous matrix and/or those incorporated into fine clay minerals. About 822 and 1110 ppm inorganic elements were eluted into the extracts of IL and WY coals, respectively. Fe was the most prevalent. The transition metals including Cr, Ni, Mn, Co, Cu, and Zn were also abundant. These metals were mostly nitric-acid insoluble. Electron spin resonance spectroscopy characterization suggested the high-spin Fe{sup 3+} state for Fe that is virtually totally associated with coal functional groups. Regarding the remaining metals in coal extracts, they are mainly submicrometer discrete particles in IL extract. Elution of the ion-exchangeable carboxylates was however prominent during WY coal extraction. 43 refs., 6 figs., 5 tabs.

  10. Remotely serviced filter and housing

    DOEpatents

    Ross, M.J.; Zaladonis, L.A.

    1987-07-22

    A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station. 6 figs.

  11. An IIR median hybrid filter

    NASA Technical Reports Server (NTRS)

    Bauer, Peter H.; Sartori, Michael A.; Bryden, Timothy M.

    1992-01-01

    A new class of nonlinear filters, the so-called class of multidirectional infinite impulse response median hybrid filters, is presented and analyzed. The input signal is processed twice using a linear shift-invariant infinite impulse response filtering module: once with normal causality and a second time with inverted causality. The final output of the MIMH filter is the median of the two-directional outputs and the original input signal. Thus, the MIMH filter is a concatenation of linear filtering and nonlinear filtering (a median filtering module). Because of this unique scheme, the MIMH filter possesses many desirable properties which are both proven and analyzed (including impulse removal, step preservation, and noise suppression). A comparison to other existing median type filters is also provided.

  12. Filters for cathodic arc plasmas

    DOEpatents

    Anders, Andre; MacGill, Robert A.; Bilek, Marcela M. M.; Brown, Ian G.

    2002-01-01

    Cathodic arc plasmas are contaminated with macroparticles. A variety of magnetic plasma filters has been used with various success in removing the macroparticles from the plasma. An open-architecture, bent solenoid filter, with additional field coils at the filter entrance and exit, improves macroparticle filtering. In particular, a double-bent filter that is twisted out of plane forms a very compact and efficient filter. The coil turns further have a flat cross-section to promote macroparticle reflection out of the filter volume. An output conditioning system formed of an expander coil, a straightener coil, and a homogenizer, may be used with the magnetic filter for expanding the filtered plasma beam to cover a larger area of the target. A cathodic arc plasma deposition system using this filter can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

  13. Anti-clogging filter system

    SciTech Connect

    Brown, Erik P.

    2015-05-19

    An anti-clogging filter system for filtering a fluid containing large particles and small particles includes an enclosure with at least one individual elongated tubular filter element in the enclosure. The individual elongated tubular filter element has an internal passage, a closed end, an open end, and a filtering material in or on the individual elongated tubular filter element. The fluid travels through the open end of the elongated tubular element and through the internal passage and through the filtering material. An anti-clogging element is positioned on or adjacent the individual elongated tubular filter element and provides a fluid curtain that preferentially directs the larger particulates to one area of the filter material allowing the remainder of the filter material to remain more efficient.

  14. Filter cake characterization studies

    SciTech Connect

    Newby, R.A.; Smeltzer, E.E.; Alvin, M.A.; Lippert, T.E.

    1995-11-01

    The Westinghouse Electric Corporation, Science & Technology Center is developing an Integrated Low Emissions Cleanup (ILEC) concept for high-temperature gas cleaning to meet environmental standards, as well as to provide gas turbine protection. The ILEC system is a ceramic barrier hot gas filter (HGF) that removes particulate while simultaneously contributing to the control of sulfur, alkali, and potentially other contaminants in high-temperature, high-pressure fuel gases, or combustion gases. The gas-phase contaminant removal is performed by sorbent particles injected into the HGF. The overall objective of this program is to demonstrate, at a bench scale, the technical feasibility of the ILEC concept for multi-contaminant control, and to provide test data applicable to the design of subsequent field tests. The program has conducted ceramic barrier filter testing under simulated PFBC conditions to resolve issues relating to filter cake permeability, pulse cleaning, and filter cake additive performance. ILEC testing has also been performed to assess the potential for in-filter sulfur and alkali removal.

  15. Filter component assessment

    SciTech Connect

    Alvin, M.A.; Lippert, T.E.; Diaz, E.S.; Smeltzer, E.W.

    1995-11-01

    The objectives of this program are to provide a more ruggedized filter system that utilizes porous ceramic filters which have improved resistance to damage resulting from crack propagation, thermal fatigue and/or thermal excursions during plant or process transient conditions, and/or mechanical ash bridging events within the candle filter array. As part of the current Phase 1, Task 1, effort of this program, Westinghouse is evaluating the filtration characteristics, mechanical integrity, and corrosion resistance of the following advanced or second generation candle filters for use in advanced coal-fired process applications: 3M CVI-SiC composite--chemical vapor infiltration of silicon carbide into an aluminosilicate Nextel{trademark} 312 fiber preform; DuPont PRD-66--filament wound candle filter structure containing corundum, cordierite, cristobalite, and mullite; DuPont SiC-SiC--chemical infiltration of silicon carbide into a silicon carbide Nicalon{trademark} fiber mat or felt preform; and IF and P Fibrosic{trademark}--vacuum infiltrated oxide-based chopped fibrous matrix. Results to date are presented.

  16. Multilayer volume microwave filters

    NASA Astrophysics Data System (ADS)

    Gvozdev, V. I.; Smirnov, S. V.; Chernushenko, A. M.

    1985-09-01

    Multilayer volume microwave filters are particularly suitable for miniaturization of radioelectronic devices by way of circuit integration, the principal advantage over planar filters being the much higher Q-factor; Q sub 0 or = 10 to the 3rd power as compared with Q sub 0 or = 10 to the 2nd power. Their metal-dielectric structure forms an array of coupled half-wavelength resonators electrically symmetric with respect to the center layer, coupling being effected by a magnetic field normal to the plane of resonators. The structure consists of an asymmetric strip line with conductor at the input end, followed by a metal layer with cut out symmetric slot line, a dielectric layer, a symmetric strip line with conductor, a metal layer with cut out symmetric slot line, a dielectric layer, and an asymmetric strip line with conductor at the output end. The size of such a filter depends directly on the number of resonator stages and, without the case, is comparable with the size of conventional filters on symmetric strip lines only but is much smaller than that of conventional filters on asymmetric strip lines only.

  17. Properties of ceramic candle filters

    SciTech Connect

    Pontius, D.H.; Starrett, H.S.

    1994-10-01

    The objectives of this program have been: (1) the post-test evaluation of candle filters, (2) to measure the material properties of current filter materials, destructively and non-destructively, and to relate these properties and behaviors to in-service performance, (3) to develop an understanding of the material requirements for hot gas filter elements, (4) to develop material property goals for filter materials, and (5) to establish test matrices and a protocol to evaluate candidate filter materials.

  18. Filters for Submillimeter Electromagnetic Waves

    NASA Technical Reports Server (NTRS)

    Berdahl, C. M.

    1986-01-01

    New manufacturing process produces filters strong, yet have small, precise dimensions and smooth surface finish essential for dichroic filtering at submillimeter wavelengths. Many filters, each one essentially wafer containing fine metal grid made at same time. Stacked square wires plated, fused, and etched to form arrays of holes. Grid of nickel and tin held in brass ring. Wall thickness, thickness of filter (hole depth) and lateral hole dimensions all depend upon operating frequency and filter characteristics.

  19. Disinfecting Filters For Recirculated Air

    NASA Technical Reports Server (NTRS)

    Pilichi, Carmine A.

    1992-01-01

    Simple treatment disinfects air filters by killing bacteria, algae, fungi, mycobacteria, viruses, spores, and any other micro-organisms filters might harbor. Concept applied to reusable stainless-steel wire mesh filters and disposable air filters. Treatment used on filters in air-circulation systems in spacecraft, airplanes, other vehicles, and buildings to help prevent spread of colds, sore throats, and more-serious illnesses.

  20. DOE HEPA filter test program

    SciTech Connect

    1998-05-01

    This standard establishes essential elements of a Department of Energy (DOE) program for testing HEPA filters to be installed in DOE nuclear facilities or used in DOE-contracted activities. A key element is the testing of HEPA filters for performance at a DOE Filter Test Facility (FTF) prior to installation. Other key elements are (1) providing for a DOE HEPA filter procurement program, and (2) verifying that HEPA filters to be installed in nuclear facilities appear on a Qualified Products List (QPL).

  1. Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection

    NASA Astrophysics Data System (ADS)

    Gulati, Karan; Aw, Moom Sinn; Losic, Dusan

    2011-10-01

    Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems. This study presents the use of titanium [Ti] wires with titania nanotube [TNT] arrays formed with a drug delivery capability to design alternative bone fixation tools for orthopaedic applications. A titania layer with an array of nanotube structures was synthesised on the surface of a Ti wire by electrochemical anodisation and loaded with antibiotic (gentamicin) used as a model of bone anti-bacterial drug. Successful fabrication of TNT structures with pore diameters of approximately 170 nm and length of 70 μm is demonstrated for the first time in the form of wires. The drug release characteristics of TNT-Ti wires were evaluated, showing a two-phase release, with a burst release (37%) and a slow release with zero-order kinetics over 11 days. These results confirmed our system's ability to be applied as a drug-eluting tool for orthopaedic applications. The established biocompatibility of TNT structures, closer modulus of elasticity to natural bones and possible inclusion of desired drugs, proteins or growth factors make this system a promising alternative to replace conventional bone implants to prevent bone infection and to be used for targeted treatment of bone cancer, osteomyelitis and other orthopaedic diseases.

  2. The everolimus-eluting Xience stent in small vessel disease: bench, clinical, and pathology view

    PubMed Central

    Sanchez, Oscar D; Yahagi, Kazuyuki; Koppara, Tobias; Virmani, Renu; Joner, Michael

    2015-01-01

    Coronary artery disease (CAD) is the leading cause of morbidity and mortality worldwide. The pathogenesis of CAD relates to the presence of atherosclerotic plaques in the coronary arteries, which are most frequently treated today by percutaneous coronary intervention. Small vessel disease treatment represents one-third of all percutaneous coronary interventions with higher rates of restenosis and major adverse cardiac events. Initially, drug-eluting stents (DES) were developed to reduce in-stent restenosis, improving clinical outcomes and reducing the need for target vessel revascularization. However, late and very late stent thrombosis emerged as a new problem compromising DES’s long-term results. The cobalt–chromium everolimus-eluting stent (CoCr-EES) represents the results of an evolutionary process in DES technology aimed at improving the shortcomings of first-generation DES. Small vessel CAD has historically been an obstacle to long-term patency following implantation of DES. Antirestenotic efficacy has been shown to be of high relevance in small vessels. Therefore, stent selection may play an important role in determining outcomes in this subgroup of patients. This article will review the performance of CoCr-EES in the treatment of small vessel CAD from preclinical, clinical, and pathology perspectives, and it will highlight the most important findings in this regard. PMID:25565907

  3. Effect of energetic materials wettability on their outdoor effective elution rate.

    PubMed

    Lapointe, Marie-Claude; Martel, Richard; Lange, Sébastien F; Coté, Sébastien

    2016-07-01

    Energetic materials (EM) contained in military ammunitions have been found in the surface soil and water of training areas and may potentially represent a threat to human health and the environment. EM wettability is an essential physical parameter to characterize because it controls EM dissolution rate. This paper was conducted to determine the wettability of conventional and new EM formulations used in military ammunition. Wettability was estimated in the laboratory via contact angle measurements of water droplets on different EM surfaces. Results show that 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazinane (RDX), Octol and energetic thermoplastic elastomer (ETPE) 1000 are hydrophilic while Composition B, XRT, GIM, CX-85, ETPE 2000, and C4 are hydrophobic whereas HELOVA gun propellant has a mixed wettability oscillating between hydrophilic and hydrophobic. The present study demonstrates that wettability of EM formulation is generally controlled by their matrix constituents. Results indicate that hydrophobic formulations have a much slower outdoor environmental effective elution rate than hydrophilic ones, with the exception of the hydrophobic C4 formulation whose elution rate is extremely high. The addition of hydrophobic components into EM formulations is recommended to diminish the environmental impact on water, as it has already been done with XRT, GIM and CX-85 formulations. PMID:26985872

  4. Performance of HPLC/MS microchips in isocratic and gradient elution modes.

    PubMed

    Ehlert, Steffen; Trojer, Lukas; Vollmer, Martin; van de Goor, Tom; Tallarek, Ulrich

    2010-03-01

    We analyzed the chromatographic performance of particle-packed, all-polyimide high-performance liquid chromatography/mass spectrometry (HPLC/MS) microchips in terms of their hydraulic permeabilities and separation efficiency under isocratic and gradient elution conditions. The separation channels of the chips (with ca 50 microm x 75 microm trapezoidal cross-section and a length of 43 mm) were slurry packed with either 3.5 or 5 microm spherical porous C18-silica particles. A custom-built holder enveloped the chip during packing to prevent channel deformation and delamination from high pressures. It is shown that the packing conditions significantly impact the packing density of the HPLC/MS chips, which determines their performance in both, isocratic and gradient elution modes. Even with steep solvent gradients, peak shape and chromatographic resolution for the densely packed HPLC/MS chips are much improved. Our data show that the analytical power of the HPLC/MS chip is limited by the quality of the chromatographic separation. PMID:20209581

  5. Instrument parameters controlling retention precision in gradient elution reversed-phase liquid.

    PubMed

    Beyaza, Ayse; Fana, Wenzhe; Carr, Peter W; Schellinger, Adam P

    2014-12-01

    The precision of retention time in RPLC is important for compound identification, for setting peak integration time windows and in fundamental studies of retention. In this work, we studied the effect of temperature (T), initial (ϕo) and final mobile phase (ϕf) composition, gradient time (tG), and flow rate (F) on the retention time precision under gradient elution conditions for various types of low MW solutes. We determined the retention factor in pure water ( [Formula: see text] ) and the solute-dependent solvent strength (S) parameters of Snyder's linear solvent strength theory (LSST) as a function of temperature for three different groups of solutes. The effect of small changes in the chromatographic variables (T, ϕo, ϕf, tG and F) by use of the LSST gradient retention equation were estimated. Peaks at different positions in the chromatogram have different sensitivities to changes in these instrument parameters. In general, absolute fluctuations in retention time are larger at longer gradient times. Drugs showed less sensitivity to changes in temperature compared to relatively less polar solutes, non-ionogenic solutes. Surprisingly we observed that fluctuations in temperature, mobile phase composition and flow rate had less effect on retention time under gradient conditions as compared to isocratic conditions. Overall temperature and the initial mobile phase composition are the most important variables affecting retention reproducibility in gradient elution chromatography. PMID:25459648

  6. Nanoparticle Drug- and Gene-eluting Stents for the Prevention and Treatment of Coronary Restenosis

    PubMed Central

    Yin, Rui-Xing; Yang, De-Zhai; Wu, Jin-Zhen

    2014-01-01

    Percutaneous coronary intervention (PCI) has become the most common revascularization procedure for coronary artery disease. The use of stents has reduced the rate of restenosis by preventing elastic recoil and negative remodeling. However, in-stent restenosis remains one of the major drawbacks of this procedure. Drug-eluting stents (DESs) have proven to be effective in reducing the risk of late restenosis, but the use of currently marketed DESs presents safety concerns, including the non-specificity of therapeutics, incomplete endothelialization leading to late thrombosis, the need for long-term anti-platelet agents, and local hypersensitivity to polymer delivery matrices. In addition, the current DESs lack the capacity for adjustment of the drug dose and release kinetics appropriate to the disease status of the treated vessel. The development of efficacious therapeutic strategies to prevent and inhibit restenosis after PCI is critical for the treatment of coronary artery disease. The administration of drugs using biodegradable polymer nanoparticles as carriers has generated immense interest due to their excellent biocompatibility and ability to facilitate prolonged drug release. Despite the potential benefits of nanoparticles as smart drug delivery and diagnostic systems, much research is still required to evaluate potential toxicity issues related to the chemical properties of nanoparticle materials, as well as to their size and shape. This review describes the molecular mechanism of coronary restenosis, the use of DESs, and progress in nanoparticle drug- or gene-eluting stents for the prevention and treatment of coronary restenosis. PMID:24465275

  7. Drug-eluting balloon catheters for lower limb peripheral arterial disease: the evidence to date

    PubMed Central

    Barkat, Mohamed; Torella, Francesco; Antoniou, George A

    2016-01-01

    A significant proportion of patients with severe lower limb peripheral arterial disease require revascularization. Over the past decade, an endovascular-first approach even for complex disease has gained widespread use among vascular specialists. An important limitation of percutaneous transluminal balloon angioplasty or stenting remains the occurrence of restenosis. Drug-coated balloons have emerged as an exciting technology developed to overcome the limitations of standard balloon angioplasty and stenting. Drug-eluting devices inhibit neointimal growth of vascular smooth muscle cells with the potential of preventing restenosis. This review provides a synopsis of the up-to-date evidence on the role of drug-coated balloons in the treatment of lower limb peripheral arterial disease. Bibliographic searches were conducted using MEDLINE, EMBASE, and the Cochrane Library electronic database. Eleven randomized clinical trials, two systematic reviews, and a published registry providing the best available evidence were identified. Current evidence suggests that angioplasty with drug-coated balloon is reliable, safe, and efficient in increasing patency rates and reducing target lesion revascularization and restenosis. However, it remains unknown whether these improved results can translate into beneficial clinical outcomes, as current randomized clinical trials have failed to demonstrate a significant benefit in limb salvage and mortality. Further randomized trials focusing on clinical and functional outcomes of drug-eluting balloons and on cost versus clinical benefit are required. PMID:27274265

  8. In vivo performance of a drug-eluting contact lens to treat glaucoma for a month

    PubMed Central

    Ciolino, Joseph B.; Stefanescu, Cristina F.; Ross, Amy E.; Salvador-Culla, Borja; Cortez, Priscila; Ford, Eden M.; Wymbs, Kate A.; Sprague, Sarah L.; Mascoop, Daniel R.; Rudina, Shireen S.; Trauger, Sunia A.; Cade, Fabiano; Kohane, Daniel S.

    2013-01-01

    For nearly half a century, contact lenses have been proposed as a means of ocular drug delivery, but achieving controlled drug release has been a significant challenge. We have developed a drug-eluting contact lens designed for prolonged delivery of latanoprost for the treatment of glaucoma, the leading cause of irreversible blindness worldwide. Latanoprost-eluting contact lenses were created by encapsulating latanoprost–poly(lactic-co-glycolic acid) films in methafilcon by ultraviolet light polymerization. In vitro and in vivo studies showed an early burst of drug release followed by sustained release for one month. Contact lenses containing thicker drug–polymer films demonstrated released a greater amount of drug after the initial burst. In vivo, single contact lenses were able to achieve, for at least one month, latanoprost concentrations in the aqueous humor that were comparable to those achieved with topical latanoprost solution, the current first-line treatment for glaucoma. The lenses appeared safe in cell culture and animal studies. This contact lens design can potentially be used as a treatment for glaucoma and as a platform for other ocular drug delivery applications. PMID:24094935

  9. Centrifugal partition chromatography elution gradient for isolation of sesquiterpene lactones and flavonoids from Anvillea radiata.

    PubMed

    Destandau, Emilie; Boukhris, Meryem Alaoui; Zubrzycki, Sandrine; Akssira, Mohamed; Rhaffari, Lhoucine El; Elfakir, Claire

    2015-03-15

    An innovative procedure coupling pressurized solvent extraction and centrifugal partition chromatography (CPC) used in linear gradient elution mode was developed to isolate two pure germacranolides (9α-hydroxyparthenolide and 9β-hydroxyparthenolide) and to separate flavonoids (nepetin, isorhamnetin and jaceosidin) and chlorophyll pigments from aerial parts of Anvillea radiata (Coss.&Durieu). The two main germacranolides recovered using this method represent 2 and 5% of the dried plant material respectively. These molecules were extracted using accelerated solvent extraction with chloroform. After optimization of the CPC method, a two-phase solvent system composed of heptane/ethyl acetate/methanol/water (1:5:1:5 v/v/v/v) was employed in descending mode to isolate the germacranolides. Then the lower phase of a heptane/ethyl acetate/methanol/water (6:5:6:5 v/v/v/v) system was pumped in descending mode to generate a linear elution gradient, progressively decreasing the mobile phase polarity, that enabled the flavonoid compounds to be separated in the same run. The efficiency of the preparative separation was controlled through RP-HPLC analysis of the obtained fractions using UV, evaporative light scattering and mass spectrometry detection. The structural identification of the two germacranolides purified over 99% was established by (1)H NMR and (13)C NMR. The least abundant flavonoids were identified by mass spectrometry. PMID:25647341

  10. Effect of Food Stimulated Liquids and Thermocycling on the Monomer Elution from a Nanofilled Composite

    PubMed Central

    Tabatabaei, Masumeh Hasani; Sadrai, Sima; Bassir, Seyed Hossein; Veisy, Nadia; Dehghan, Somaye

    2013-01-01

    The present study was aimed to evaluate the effects of food simulating liquids and thermocycling on the elution of monomers from a nanofilled resin composite in different immersion times. Five Specimen discs were made from a nano-hybrid composite (Supreme 3M) for each group (Total = 180) and immersed in distilled water (control), citric acid, lactic acid, and 75% aqueous ethanol solution. The discs were removed after 24 h, 48 h, 72 h, 1 wk, 4 wk, and 12 wk. Three groups of samples underwent thermocycling for 1000, 2000 and 3000 cycles. The solutes were analyzed with HPLC for detection of eluted monomers. The results showed that the amount of released TEGDMA was significantly higher than that of Bis-GMA; however, there were not any significant differences between the amount of released Bis-GMA and UDMA. Moreover, the highest amount of monomers was released from samples immersed in ethanol solution; samples immersed in citric acid and lactic acid significantly released more monomers than those immersed in distilled water. Furthermore, the immersion time in aqueous ethanol solution had an increasing effect on the release of monomers. In addition, the higher amounts of monomers were release from samples immersed in ethanol and citric acid which underwent a higher number of thermal cycles. In conclusion, food and drink stimulated liquids used in this study increased the amount of some of the monomers released from composite resin. Thermal shocks and storage time are other factors that increased the release of monomers from the composite resin PMID:23986791

  11. Serial gray scale intravascular ultrasound findings in late drug-eluting stent restenosis.

    PubMed

    Hakim, Diaa A; Mintz, Gary S; Sanidas, Elias; Rusinova, Reni; Weisz, Giora; Leon, Martin B; Moses, Jeffery W; Stone, Gregg W; Maehara, Akiko

    2013-03-01

    The primary aim of the present study was to assess the gray scale intravascular ultrasound (IVUS) findings that might be associated with late drug-eluting stent restenosis. The study included 47 patients (54 lesions) who had undergone either baseline IVUS-guided stent implantation or IVUS-guided repeat stenting to treat in-stent restenosis and then had IVUS follow-up data for ≥1.5 years afterward without any intervening procedures. The left anterior descending artery was the culprit in 59% of cases, and 50% of the lesions were at bifurcation sites. Quantitative and qualitative IVUS analyses showed a decreased minimum lumen area at follow-up from 6.0 ± 1.8 to 3.8 ± 1.4 mm(2) (p <0.0001) that was mainly due to neointimal hyperplasia with chronic stent recoil (defined as a >15% decrease in minimum stent area) in only 2 lesions and stent fracture in only 5 lesions. Calcified neointima appeared in 12 lesions, mostly in the form of macrocalcification, and was associated with increased calcium both behind the stent and in the reference segment. In conclusion, late drug-eluting stent restenosis showed neointimal calcification in 20% of cases, and chronic stent recoil was rare. PMID:23273714

  12. Instrument Parameters Controlling Retention Precision in Gradient Elution Reversed-Phase Liquid Chromatography

    PubMed Central

    Beyaz, Ayse; Fan, Wenzhe; Carr, Peter W.; Schellinger, Adam P.

    2014-01-01

    The precision of retention time in RPLC is important for compound identification, for setting peak integration time windows and in fundamental studies of retention. In this work, we studied the effect of temperature (T), initial (ϕ0) and final mobile phase (ϕf)composition, gradient time (tG), and flow rate (F) on the retention time precision under gradient elution conditions for various types of low MW solutes. We determined the retention factor in pure water (k′w) and the solute-dependent solvent strength (S) parameters of Snyder's linear solvent strength theory (LSST) as a function of temperature for three different groups of solutes. The effect of small changes in the chromatographic variables (T, ϕ0, ϕf, tG and F) by use of the LSST gradient retention equation were estimated. Peaks at different positions in the chromatogram have different sensitivities to changes in these instrument parameters. In general, absolute fluctuations in retention time are larger at longer gradient times. Drugs showed less sensitivity to changes in temperature compared to relatively less polar solutes, non-ionogenic solutes. Surprisingly we observed that fluctuations in temperature, mobile phase composition and flow rate had less effect on retention time under gradient conditions as compared to isocratic conditions. Overall temperature and the initial mobile phase composition are the more important variables affecting retention reproducibility in gradient elution chromatography. PMID:25459648

  13. Peak Capacity Optimization of Peptide Separations in Reversed-Phase Gradient Elution Chromatography

    PubMed Central

    Wang, Xiaoli; Stoll, Dwight R; Schellinger, Adam P; Carr, Peter W.

    2008-01-01

    The optimization of peak capacity in gradient elution RPLC is essential for the separation of multi-component samples such as those encountered in proteomic research. In this work we study the effect of gradient time (tG), flow rate (F), temperature (T) and final eluent strength (ϕfinal) on the peak capacity of separations of peptides that are representative of the range in peptides found in a tryptic digest. We find that there are very strong interactions between the individual variables (e.g. flow rate and gradient time) which make the optimization quite complicated. On a given column, one should first set the gradient time to the longest tolerable and then set the temperature to the highest achievable with the instrument. Next, the flow rate should be optimized using a reasonable but arbitrary value of ϕfinal. Last, the final eluent strength should be adjusted so that the last solute elutes as close as possible to the gradient time. We also develop an easily implemented, highly efficient and effective Monte Carlo search strategy to simultaneously optimize all the variables. We find that gradient steepness is an important parameter that influences peak capacity and an optimum range of gradient steepness exists in which the peak capacity is maximized. PMID:16689544

  14. New drug-eluting lenses to be applied as bandages after keratoprosthesis implantation.

    PubMed

    Carreira, A S; Ferreira, P; Ribeiro, M P; Correia, T R; Coutinho, P; Correia, I J; Gil, M H

    2014-12-30

    Corneal tissue is the most commonly transplanted tissue worldwide. This work aimed to develop a new drug-eluting contact lens that may be used as a bandage after keratoprosthesis. During this work, films were produced using poly(vinyl alcohol) (PVA) and chitosan (CS) crosslinked with glyoxal (GL). Vancomycin chlorhydrate (VA) was impregnated in these systems by soaking. Attenuated total reflectance - Fourier transform infrared spectroscopy was used to confirm crosslinking. The cytotoxic and drug release profile, hydrophilicity, thermal and biodegradation as well as swelling capacity of the samples were assessed through in vitro studies. PVA and PVA/CS films were obtained by crosslinking with GL. The films were transparent, flexible with smooth surfaces, hydrophilic and able to load and release vancomycin for more than 8h. Biodegradation in artificial lachrymal fluid (ALF) with lysozyme at 37°C showed that mass loss was higher for the samples containing CS. Also, the samples prepared with CS showed the formation of pores which were visualized by SEM. All samples revealed a biocompatible character after 24h in contact with cornea endothelial cells. As a general conclusion it was possible to determine that the 70PVA/30CS film showed to combine the necessary features to prepare vancomycin-eluting contact lenses to prevent inflammation after corneal substitution. PMID:25455772

  15. Effect of ionic additives on the elution of sodium aryl sulfonates in supercritical fluid chromatography.

    PubMed

    Zheng, J; Taylor, L T; Pinkston, J David; Mangels, M L

    2005-08-01

    Addition of a small amount of polar solvent (i.e., modifier) to CO2 in packed column supercritical fluid chromatography (SFC) has shown major improvements in both polar analyte solubility and interaction of the polar analyte with the stationary phase. Recently, the addition of an ionic component (i.e., additive) to the primary modifier by one of us has been shown to extend even further the application of SFC to polar analytes. In this work, the effect of various ionic additives on the elution of ionic compounds, such as sodium 4-dodecylbenzene sulfonate and sodium 4-octylbenene sulfonate, has been studied. The additives were lithium acetate, ammonium acetate, tetramethylammonium acetate, tetrabutylammonium acetate, and ammonium chloride dissolved in methanol. Three stationary phases with different degrees of deactivation were considered: conventional cyanopropyl, deltabond cyanopropyl, and bare silica. The effect of additive concentration and additive functionality on analyte retention was investigated. Sodium 4-dodecylbenzene sulfonate was successfully eluted using all the additives with good peak shape under isocratic/isobaric/isothermal conditions. Different additives, however, yielded different retention times and in some cases different peak shapes. PMID:16035365

  16. Characterizing and modeling of extensive atrazine elution tailing for stable manure-amended agricultural soil.

    PubMed

    Akyol, Nihat Hakan

    2015-01-01

    Non-ideal sorption and extensive elution tailing behavior of atrazine was evaluated for an agricultural soil with and without stable manure amendment (10% by weight). A series of laboratory experiments showed that the sorption of atrazine was described by rate-limited, nonlinear reversible processes (Freundlich isotherm) for both non-amended and amended soil. Non-ideal transport of atrazine exhibited extensive low concentration elution tailing due to the most likely organic carbon fraction in the soil. This tailing behavior was more pronounced and extensive for soil with 10% stable-manure amendment. Two-site transport modeling analyses including non-linear sorption and rate-limited sorption-desorption provided a reasonably good match to the atrazine breakthrough curves but were unable to match the long-term concentration tailing, even for non-amended soil. A mathematical model incorporating nonlinear, rate-limited sorption/desorption described by a continuous-distribution function was used to successfully simulate atrazine transport early-time breakthrough and long-term concentration tailing for both non-amended and amended soil conditions. PMID:25303664

  17. Preparation, degradation and in vitro release of ciprofloxacin-eluting ureteral stents for potential antibacterial application.

    PubMed

    Ma, Xiaofei; Xiao, Yan; Xu, Heng; Lei, Kun; Lang, Meidong

    2016-09-01

    Drug-eluting stents with biodegradable polymers as reservoirs have shown great potential in the application of interventional therapy due to their capability of local drug delivery. Herein, poly(l-lactide-co-ε-caprolactone) (PLCL) with three different compositions as carriers for ciprofloxacin lactate (CIP) was coated on ureteral stents by the dipping method. To simulate a body environment, degradation behavior of PLCL as both the bulk film and the stent coating was evaluated in artificial urine (AU, pH6.20) respectively at 37°C for 120days by tracing their weight/Mn loss, water absorption and surface morphologies. Furthermore, the release profile of the eluting drug CIP on each stent exhibited a three-stage pattern, which was greatly affected by the degradation behavior of PLCL except for the burst stage. Interestingly, the degradation results on both macroscopic and molecular level indicated that the release mechanism at stage I was mainly controlled by chain scission instead of the weight loss or morphological changes of the coatings. While for stage II, the release profile was dominated by erosion resulting from the hydrolysis reaction autocatalyzed by acidic degradation residues. In addition, ciprofloxacin-loaded coatings displayed a significant bacterial resistance against E. coli and S. aureus without obvious cytotoxicity to Human foreskin fibroblasts (HFFs). Our results suggested that PLCL copolymers with tunable degradation rate as carriers for ciprofloxacin lactate could be used as a promising long-term antibacterial coating for ureteral stents. PMID:27207042

  18. Optical coherence tomographic observations of polytetrafluoroethylene-covered sirolimus-eluting coronary arterial stent.

    PubMed

    Hou, Jingbo; Jia, Haibo; Huang, Xingtao; Yu, Huai; Ren, Xuefeng; Fang, Yan; Han, Zhigang; Yang, Shuang; Meng, Lingbo; Zhang, Shaosong; Yu, Bo; Jang, Ik-Kyung

    2013-04-15

    The aim of this study was to evaluate neointimal coverage obtained using a new method of polytetrafluoroethylene-covered stent (PCS) implantation combined with underlying longer sirolimus-eluting stent (SES) implantation using optical coherence tomography. Nine patients were enrolled in this study, including patients with coronary artery perforations, original coronary aneurysms, and acquired coronary aneurysms after drug-eluting stent implantation. All patients were first treated with long SES implantation and then with focal PCS implantation. Postprocedural and follow-up angiographic and optical coherence tomographic examinations were performed in all patients, and intravascular ultrasound was performed in 5 patients. All patients were asymptomatic during follow-up, without recurrent angina. There was no stent-edge or stent-segment binary restenosis. Values of late loss for proximal SES segments, PCS segments, and distal SES segments were similar (0.09, 0.07, and 0.04 mm, respectively, p = 0.8113). The mean neointimal thickness of PCS was less than that of proximal and distal SES. However, no malapposed cross sections or uncovered cross sections were found in PCS segments compared with SES segments (p = 0.0011). In conclusion, the combination of PCS and underlying longer SES implantation can offer better angiographic follow-up results. High-resolution optical coherence tomography provided convincing proof of full neointimal coverage of PCS. This new method of combined PCS and SES implantation may be a better choice compared with direct PCS implantation in certain clinical settings. PMID:23351458

  19. Overcoming the high-temperature two-dimensional gas chromatography limits to elute heavy compounds.

    PubMed

    Mahé, Laure; Courtiade, Marion; Dartiguelongue, Cyril; Ponthus, Jérémie; Souchon, Vincent; Thiébaut, Didier

    2012-03-16

    Overcoming high-temperature (HT) two-dimensional gas chromatography (GC × GC) limits is critical for the analysis of heavy hydrocarbons, particularly those contained in heavy petroleum fractions. To reach this goal, HT-GC × GC analysis was adapted from HT-GC Simulated Distillation (HT-GC SimDist) operating conditions as this analysis embraces compounds whose boiling point ranges from 35 °C to 700 °C and from a previous study that enabled the elution of linear alkane nC(60) and tetraaromatic compounds by HT-GC × GC. This paper shows that HT-GC × GC analysis using CO(2) cryogenic modulator and short wide bore columns with a thin film of stationary phase allows the elution of linear alkanes up to nC(68) (641 °C) as well as of highly aromatic hydrocarbons like coronene. Furthermore, compared to previous studies, an on-column injector was used to reduce discrimination of high boiling point compounds. PMID:22307150

  20. Numerical modeling of the elution peak profiles of retained solutes in supercritical fluid chromatography

    SciTech Connect

    Kaczmarski, Krzysztof; Guiochon, Georges A

    2011-01-01

    In supercritical fluid chromatography (SFC), the significant expansion of the mobile phase along the column causes the formation of axial and radial gradients of temperature. Due to these gradients, the mobile phase density, its viscosity, its velocity, its diffusion coefficients, etc. are not constant throughout the column. This results in a nonuniform flow velocity distribution, itself causing a loss of column efficiency in certain cases, even at low flow rates, as they do in HPLC. At high flow rates, an important deformation of the elution profiles of the sample components may occur. The model previously used to account satisfactorily for the retention of an unsorbed solute in SFC is applied to the modeling of the elution peak profiles of retained compounds. The numerical solution of the combined heat and mass balance equations provides the temperature and the pressure profiles inside the column and values of the retention time and the band profiles of retained compounds that are in excellent agreement with independent experimental data for large value of mobile phase reduced density. At low reduced densities, the band profiles can strongly depend on the column axial distribution of porosity.

  1. Stent thrombosis with drug-eluting stents: is the paradigm shifting?

    PubMed

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Mariani, Andrea; Genereux, Philippe; Branzi, Angelo; Stone, Gregg W

    2013-11-19

    First-generation drug-eluting stents (DES), which impart the controlled release of sirolimus or paclitaxel from durable polymers to the vessel wall, have been consistently shown to reduce the risk of restenosis and target vessel revascularization compared with bare metal stents (BMS). However, stent thrombosis (ST) emerged as a major safety concern with first-generation DES early after their adoption in clinical practice, requiring prolonged dual antiplatelet therapy. Pathological studies have shown that first-generation DES are associated with delayed arterial healing and polymer hypersensitivity reactions resulting in chronic inflammation, predisposing to late and very late ST. Second-generation DES have been developed to overcome these issues with improved stent designs and construction and the use of biocompatible and bioabsorbable polymers. Meta-analyses have shown that the thin-strut, fluoropolymer-coated cobalt-chromium everolimus-eluting stent (CoCr-EES) may be associated with lower rates of definite ST than other DES and, unexpectedly, even lower than BMS. The thin-strut structure of the stent platform, the thromboresistant properties of the fluoropolymer, and the reduced polymer and drug load may contribute to the low rate of ST with CoCr-EES. The notion of DES being safer than BMS represents a paradigm shift in the evolution of percutaneous coronary intervention. The relative safety and efficacy of fluoropolymer-coated CoCr-EES, DES with bioabsorbable polymers, and fully bioresorbable scaffolds are the subject of numerous ongoing large-scale trials. PMID:24036025

  2. Usefulness of Everolimus-Eluting Coronary Stent Implantation in Patients on Maintenance Hemodialysis.

    PubMed

    Ikari, Yuji; Kyono, Hiroyuki; Isshiki, Takaaki; Ishizuka, Shuichi; Nasu, Kenya; Sano, Koichi; Okada, Hisayuki; Sugano, Teruyasu; Uehara, Yoshiki

    2015-09-15

    The outcomes of second-generation drug-eluting stent (DES) are unknown in patients on maintenance hemodialysis (HD) although HD has been reported as a strong predictor of adverse outcome after the first-generation DES implantation. The OUCH-PRO Study is a prospective multicenter single-arm registry design to study clinical and angiographic outcomes after everolimus-eluting stent (EES). Patients who underwent maintenance HD were prospectively enrolled at the time of elective coronary intervention using EES. Quantitative coronary angiography was performed in an independent core laboratory. The primary end point was the occurrence of target vessel failure (TVF) defined as cardiac death, myocardial infarction (MI), and target vessel revascularization at 1 year. A total of 123 patients were enrolled and 161 EES were implanted. The TVF rate at 1 year was 18% (4% cardiac death, 0% MI, 17% target vessel revascularization). No stent thrombosis was documented. Other clinical events at 1 year were 3% noncardiac death, 3% stroke, and 9% non-target-vessel revascularization. Late lumen loss in stent was 0.37 ± 0.63 mm at 8 months. In conclusion, EES had a high TVF rate and great late lumen loss in patients on HD compared with previous huge EES data in non-HD patients. PMID:26219496

  3. Isolation, LC-MS/MS and 2D-NMR characterization of alkaline degradants of tenofovir disoproxil fumarate.

    PubMed

    Anandgaonkar, Vaibhav; Gupta, Abhishek; Kona, Srinivas; Talluri, M V N Kumar

    2015-03-25

    The present work describes the preparative isolation and characterization of two alkaline degradation products of tenofovir disoproxil fumarate (TDF). Tenofovir disoproxil is a prodrug of tenofovir (antiviral agent) and co-crystal form of this prodrug with fumaric acid is tenofovir disoproxil fumarate. The drug is subjected to alkaline degradation with 0.1N sodium hydroxide for 2 min at room temperature. The two degradants were detected by high performance liquid chromatography (HPLC) at relative retention of 0.26 and 0.73 with respect to the drug. HPLC method involves gradient elution on Kromasil Eternity column (150 mm × 2.1 mm, 2.5 μm) using ammonium acetate (10mM) - acetonitrile as mobile phase at flow rate of 0.3 mL/min and UV detection at 260 nm. Two degradation products were isolated by preparative HPLC and further characterized by LC-MS, (1)H NMR, (13)C NMR and 2D-NMR. On the basis of this spectral data, the structure of two DPs are confirmed as methyl hydrogen ({[1-(6-amino-9H-purin-9-yl)propan-2-yl]oxy}methyl)phosphonate for DP-I and dimethyl ({[1-(6-amino-9H-purin-9-yl)propan-2-yl]oxy}methyl)phosphonate for DP-II. PMID:25594895

  4. Stack filter classifiers

    SciTech Connect

    Porter, Reid B; Hush, Don

    2009-01-01

    Just as linear models generalize the sample mean and weighted average, weighted order statistic models generalize the sample median and weighted median. This analogy can be continued informally to generalized additive modeels in the case of the mean, and Stack Filters in the case of the median. Both of these model classes have been extensively studied for signal and image processing but it is surprising to find that for pattern classification, their treatment has been significantly one sided. Generalized additive models are now a major tool in pattern classification and many different learning algorithms have been developed to fit model parameters to finite data. However Stack Filters remain largely confined to signal and image processing and learning algorithms for classification are yet to be seen. This paper is a step towards Stack Filter Classifiers and it shows that the approach is interesting from both a theoretical and a practical perspective.

  5. Kalman filter modeling

    NASA Technical Reports Server (NTRS)

    Brown, R. G.

    1984-01-01

    The formulation of appropriate state-space models for Kalman filtering applications is studied. The so-called model is completely specified by four matrix parameters and the initial conditions of the recursive equations. Once these are determined, the die is cast, and the way in which the measurements are weighted is determined foreverafter. Thus, finding a model that fits the physical situation at hand is all important. Also, it is often the most difficult aspect of designing a Kalman filter. Formulation of discrete state models from the spectral density and ARMA random process descriptions is discussed. Finally, it is pointed out that many common processes encountered in applied work (such as band-limited white noise) simply do not lend themselves very well to Kalman filter modeling.

  6. Size-exclusion chromatography of biological samples which contain extremely alkaline proteins.

    PubMed

    Hayakawa, Kou; Guo, Lei; Terentyeva, Elena A; Li, Xiao Kang; Kimura, Hiromitsu; Hirano, Masahiko; Yoshikawa, Kazuyuki; Yoshinaga, Teruo; Nagamine, Takeaki; Katsumata, Noriyuki; Tanaka, Toshiaki

    2003-06-30

    An improved size-exclusion chromatography (SEC) was developed to isolate extremely basic (alkaline) proteins, such as trypsin (pI=10.5), lysozyme (pI=11), and histone (pI=10.8). Develosil 300 Diol-5 (300 x 8 mm I.D., 30 nm average pore diameter) column was used with an eluent of 0.1 M sodium phosphate, 1.5 M sodium chloride, glycerol (40%, v/v), 2-propanol (10%, v/v), and Brij-58 (1%, v/v). Under these conditions, the final apparent pH becomes to 4.0, and pH adjustment is not necessary. Column temperature and flow rate were 15 degrees C and 0.2 ml/min, respectively. This elution system is stable and reliable, and applications onto human pancreatic juice, human bile, and tissue homogenates were successfully achieved. Since this system is convenient for protein analysis, it is expected to be generally applicable to clinical and biochemical research for identifying protein components in combination with microsequencing. PMID:12834974

  7. Technetium removal column flow testing with alkaline, high salt, radioactive tank waste

    SciTech Connect

    Blanchard, D.L. Jr.; Kurath, D.E.; Golcar, G.R.; Conradson, S.D.

    1996-09-30

    This report describes two bench-scale column tests conducted to demonstrate the removal of Tc-99 from actual alkaline high salt radioactive waste. The waste used as feed for these tests was obtained from the Hanford double shell tank AW-101, which contains double shell slurry feed (DSSF). The tank sample was diluted to approximately 5 M Na with water, and most of the Cs-137 was removed using crystalline silicotitanates. The tests were conducted with two small columns connected in series, containing, 10 mL of either a sorbent, ABEC 5000 (Eichrom Industries, Inc.), or an anion exchanger Reillex{trademark}-HPQ (Reilly Industries, Inc.). Both materials are selective for pertechnetate anion (TcO{sub 4}{sup -}). The process steps generally followed those expected in a full-scale process and included (1) resin conditioning, (2) loading, (3) caustic wash to remove residual feed and prevent the precipitation of Al(OH){sub 3}, and (4) elution. A small amount of Tc-99m tracer was added as ammonium pertechnetate to the feed and a portable GEA counter was used to closely monitor the process. Analyses of the Tc-99 in the waste was performed using ICP-MS with spot checks using radiochemical analysis. Technetium x-ray absorption spectroscopy (XAS) spectra of 6 samples were also collected to determine the prevalence of non-pertechnetate species [e.g. Tc(IV)].

  8. Groundspeed filtering for CTAS

    NASA Technical Reports Server (NTRS)

    Slater, Gary L.

    1994-01-01

    Ground speed is one of the radar observables which is obtained along with position and heading from NASA Ames Center radar. Within the Center TRACON Automation System (CTAS), groundspeed is converted into airspeed using the wind speeds which CTAS obtains from the NOAA weather grid. This airspeed is then used in the trajectory synthesis logic which computes the trajectory for each individual aircraft. The time history of the typical radar groundspeed data is generally quite noisy, with high frequency variations on the order of five knots, and occasional 'outliers' which can be significantly different from the probable true speed. To try to smooth out these speeds and make the ETA estimate less erratic, filtering of the ground speed is done within CTAS. In its base form, the CTAS filter is a 'moving average' filter which averages the last ten radar values. In addition, there is separate logic to detect and correct for 'outliers', and acceleration logic which limits the groundspeed change in adjacent time samples. As will be shown, these additional modifications do cause significant changes in the actual groundspeed filter output. The conclusion is that the current ground speed filter logic is unable to track accurately the speed variations observed on many aircraft. The Kalman filter logic however, appears to be an improvement to the current algorithm used to smooth ground speed variations, while being simpler and more efficient to implement. Additional logic which can test for true 'outliers' can easily be added by looking at the difference in the a priori and post priori Kalman estimates, and not updating if the difference in these quantities is too large.

  9. [Two steps elution method FI on-line adsorption and preconcentration coupled with FAAS for the determination of trace zinc].

    PubMed

    Wang, Zhong-yuan; Zhang, Hong-kang; Fang, Hong-da; Su, Yao-dong; Mittal, Gauri S

    2011-12-01

    A flow injection two steps elution method on-line sorption and preconcentration system coupled to flame atomic absorption spectrometry (FAAS) was developed for the determination of trace Zn in water samples. The conventional elution procedure was divided into two steps: elution procedure and detection procedure. During the elution procedure, the eluent was pumped into KR by the suction of the peristaltic pump and through PTFE tube instead of peristaltic pump tube. By the new method, the dispersion of the analyte was decreased notably, and high absorbance peak value was achieved. Because the eluent was not through the peristaltic pump tube, the peristaltic pump tube was protected from being eroded. Emptying procedure was added in order to insure the veracity and repeatability of the experiment of every time. With 60 s (sample throughput of 37 x h(-1)) of sampling at a flow rate of 6.0 mL x min(-1), an enhancement factor (EF) of 28 (higher than 9 achieved by conventional elution method) and a detection limit (3sigma) of 0.35 x L(-1) were obtained. The precision (RSD, n=11) was 2.1% at the 20 microg x L(-1) level. When 0.1% phi triethannolamine was used as masking reagent, the recovery rate was from 98.7% to 99.6%. PMID:22295800

  10. Evaluation of the Effectiveness of Surfactants and Denaturants to Elute and Denature Adsorbed Protein on Different Surface Chemistries.

    PubMed

    Thyparambil, Aby A; Wei, Yang; Latour, Robert A

    2015-11-01

    The elution and/or denaturation of proteins from material surfaces by chemical excipients such as surfactants and denaturants is important for numerous applications including medical implant reprocessing, bioanalyses, and biodefense. The objective of this study was to develop and apply methods to quantitatively assess how surface chemistry and adsorption conditions influence the effectiveness of three commonly used surfactants (sodium dodecyl sulfate, n-octyl-β-d-glucoside, and 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate) and two denaturants (guanidium hydrochloride and urea) to elute protein (hen egg white lysozyme and bovine pancreatic ribonuclease A) from three different surface chemistries (silica glass, poly(methyl methacrylate), and high-density polyethylene). The structure and bioactivity of residual protein on the surface following elution were characterized using circular dichroism spectropolarimetry and enzyme assays to assess the extent of protein denaturation. Our results indicate that the denaturants were generally more effective than the surfactants in removing the adsorbed proteins from each type of surface. Also, the denaturing capacity of these excipients on the residual proteins on the surfaces was distinctly different from their influence on the proteins in solution and was unique for each of the adsorption conditions. Taken altogether, these results reveal that the effectiveness of surfactants and denaturants to elute and denature adsorbed protein is significantly influenced by surface chemistry and the conditions from which the protein was adsorbed. These results provide a basis for the selection, design, and further development of chemical agents for protein elution and surface decontamination. PMID:26449787

  11. Electronically tuned optical filters

    NASA Technical Reports Server (NTRS)

    Castellano, J. A.; Pasierb, E. F.; Oh, C. S.; Mccaffrey, M. T.

    1972-01-01

    A detailed account is given of efforts to develop a three layer, polychromic filter that can be tuned electronically. The operation of the filter is based on the cooperative alignment of pleochroic dye molecules by nematic liquid crystals activated by electric fields. This orientation produces changes in the optical density of the material and thus changes in the color of light transmitted through the medium. In addition, attempts to improve materials and devices which employ field induced changes of a cholesteric to a nematic liquid crystal are presented.

  12. Alkaline chemistry of transuranium elements and technetium and the treatment of alkaline radioactive wastes

    SciTech Connect

    Delegard, C.H.; Peretrukhin, V.F.; Shilov, V.P.; Pikaev, A.K.

    1995-05-01

    Goal of this survey is to generalize the known data on fundamental physical-chemical properties of TRUs and Tc, methods for their isolation, and to provide recommendations that will be useful for partitioning them from alkaline high-level wastes.

  13. Determination of Chemical Compounds Generated from Second-generation E-cigarettes Using a Sorbent Cartridge Followed by a Two-step Elution Method.

    PubMed

    Uchiyama, Shigehisa; Senoo, Yui; Hayashida, Hideki; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2016-01-01

    We developed an analytical method for analyzing electronic cigarette (E-cigarette) smoke, and measured the carbonyl compounds and volatile organic compounds generated by 10 brands of second-generation E-cigarettes. A glass filter (Cambridge filter pad) for particulate matter and a solid sorbent tube packed with Carboxen-572 for gaseous compounds were used to collect E-cigarette smoke. These were then analyzed using a two-step elution method with carbon disulfide and methanol, followed by high-performance liquid chromatography (HPLC) and gas chromatography mass spectrometry (GC/MS). Formaldehyde (FA), acetaldehyde (AA), acetone (AC), acrolein (ACR), propanal (PA), acetol (AT), glyoxal (GO), and methyl glyoxal (MGO) were detected by HPLC in some E-cigarettes. Propylene glycol (PG), glycerol (GLY), and some esters were detected by GC/MS. GO and MGO exist mainly as particulate matter. AA, AC, ACR, PA, and AT exist mainly as gaseous compounds. FA exists as both particulate matter and gaseous compounds. These carbonyl compounds have carbon numbers C1 - C3. The main components of E-liquid are PG (C3) and GLY (C3). Therefore, the oxidation of liquids, such as PG and GLY in E-cigarettes upon incidental contact with the heating element in E-cigarette, is suggested as being a possible cause for carbonyl generation. When the puff number exceeds a critical point, carbonyl generation rapidly increases and then remains constant. The results of this study are now being used to determine the following E-cigarette smoking protocol: puff volume, 55 mL; puff duration, 2 s; and puff number, 30. E-cigarette analysis revealed very large variation in carbonyl concentration among not only different brands, but also different samples of the same product. Typical distributions of carbonyl concentration were not observed in any of the E-cigarettes tested, and the mean values greatly differed from median values. PMID:27169655

  14. Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials).

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; Masotti, Mónica; López-Minguez, José R; Iñiguez, Andrés; Zueco, Javier; Velazquez, Maite; Cequier, Angel; Lázaro-García, Rosa; Martí, Vicens; Moris, César; Urbano-Carrillo, Cristobal; Bastante, Teresa; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-02-15

    Treatment of patients with in-stent restenosis (ISR) remains a challenge. This study sought to compare the efficacy of everolimus-eluting stents (EESs) and drug-eluting balloons (DEBs) with paclitaxel in patients with ISR. A pooled analysis of the Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS IV) and Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS V) randomized trials was performed using patient-level data. In both trials, EESs were compared with DEBs in patients with ISR (RIBS V included 189 patients with bare-metal ISR; RIBS IV included 309 patients with drug-eluting ISR). Inclusion and exclusion criteria were identical in both trials. A total of 249 patients were allocated to EES and 249 to DEB. Clinical follow-up at 1 year was obtained in all (100%) patients and late angiography (median 249 days) in 91% of eligible patients. Compared with patients treated with DEBs, patients treated with EESs obtained better short-term results (postprocedural minimal lumen diameter 2.28 ± 0.5 vs 2.12 ± 0.4 mm, p <0.0001). At follow-up, patients treated with EESs had larger in-segment minimal lumen diameter (primary end point 2.16 ± 0.7 vs 1.88 ± 0.6 mm, p <0.0001; absolute mean difference 0.28 mm; 95% confidence interval [CI] 0.16 to 0.40) and net lumen gain (1.33 ± 0.6 vs 1.00 ± 0.7 mm, p <0.0001) and had lower %diameter stenosis (19 ± 21% vs 28 ± 22%, p <0.0001) and binary restenosis rate (8.7% vs 15.7%, p = 0.02). Consistent results were observed in the in-lesion analysis. No interactions were found between the underlying stent type and treatment effects. At 1-year clinical follow-up, the composite of cardiac death, myocardial infarction, and target vessel revascularization was significantly reduced in the EES arm (8.8% vs 14.5%, p = 0.03; hazard ratio 0.59, 95% CI 0.31 to 0.94) mainly driven by a lower need for target vessel revascularization (6% vs 12.4%, p

  15. DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.

    SciTech Connect

    SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.

    2004-03-24

    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNA populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.

  16. Autonomous in situ measurements of seawater alkalinity.

    PubMed

    Spaulding, Reggie S; DeGrandpre, Michael D; Beck, James C; Hart, Robert D; Peterson, Brittany; De Carlo, Eric H; Drupp, Patrick S; Hammar, Terry R

    2014-08-19

    Total alkalinity (AT) is an important parameter for describing the marine inorganic carbon system and understanding the effects of atmospheric CO2 on the oceans. Measurements of AT are limited, however, because of the laborious process of collecting and analyzing samples. In this work we evaluate the performance of an autonomous instrument for high temporal resolution measurements of seawater AT. The Submersible Autonomous Moored Instrument for alkalinity (SAMI-alk) uses a novel tracer monitored titration method where a colorimetric pH indicator quantifies both pH and relative volumes of sample and titrant, circumventing the need for gravimetric or volumetric measurements. The SAMI-alk performance was validated in the laboratory and in situ during two field studies. Overall in situ accuracy was -2.2 ± 13.1 μmol kg(-1) (n = 86), on the basis of comparison to discrete samples. Precision on duplicate analyses of a carbonate standard was ±4.7 μmol kg(-1) (n = 22). This prototype instrument can measure in situ AT hourly for one month, limited by consumption of reagent and standard solutions. PMID:25051401

  17. Solubility of uranium in alkaline salt solutions

    SciTech Connect

    Hobbs, D.T.; Edwards, T.B.

    1994-03-29

    The solubility of uranium in alkaline salt solutions was investigated to screen for significant factors and interactions among the major salt components and temperature. The components included in the study were the sodium salts of hydroxide, nitrate, nitrite, aluminate, sulfate, and carbonate. General findings from the study included: (1) uranium solubilities are very low (1-20 mg/L) for all solution compositions at hydroxide concentrations from 0.1 to 17 molar (2) carbonate, sulfate, and aluminate are not effective complexants for uranium at high hydroxide concentration, (3) uranium solubility decreases with increasing temperature for most alkaline salt solutions, and (4) uranium solubility increases with changes in solution chemistry that reflect aging of high level waste (increase in nitrite and carbonate concentrations, decrease in nitrate and hydroxide concentrations). A predictive model for the concentration of uranium as a function of component concentrations and temperature was fitted to the data. All of the solution components and temperature were found to be significant. There is a significant lack of fit for the model, which suggests that the dependence on the uranium solubility over the wide range of solution compositions is non-linear and/or that there are other uncontrolled parameters which are important to the uranium solubility.

  18. Molecular modeling of human alkaline sphingomyelinase.

    PubMed

    Suresh, Panneer Selvam; Olubiyi, Olujide; Thirunavukkarasu, Chinnasamy; Strodel, Birgit; Kumar, Muthuvel Suresh

    2011-01-01

    Alkaline sphingomyelinase, which is expressed in the human intestine and hydrolyses sphingomyelin, is a component of the plasma and the lysosomal membranes. Hydrolase of sphingomyelin generates ceramide, sphingosine, and sphingosine 1-phosphate that have regulatory effects on vital cellular functions such as proliferation, differentiation, and apoptosis. The enzyme belongs to the Nucleotide Pyrophosphatase/Phosphodiesterase family and it differs in structural similarity with acidic and neutral sphingomyelinase. In the present study we modeled alkaline sphingomyelinase using homology modeling based on the structure of Nucleotide Pyrophosphatase/Phosphodiesterase from Xanthomonas axonopodis with which it shares 34% identity. Homology modeling was performed using Modeller9v7. We found that Cys78 and Cys394 form a disulphide bond. Further analysis shows that Ser76 may be important for the function of this enzyme, which is supported by the findings of Wu et al. (2005), that S76F abolishes the activity completely. We found that the residues bound to Zn(2+) are conserved and geometrically similar with the template. Molecular Dynamics simulations were carried out for the modeled protein to observe the effect of Zinc metal ions. It was observed that the metal ion has little effect with regard to the stability but induces increased fluctuations in the protein. These analyses showed that Zinc ions play an important role in stabilizing the secondary structure and in maintaining the compactness of the active site. PMID:21544170

  19. Bone alkaline phosphatase in rheumatic diseases.

    PubMed

    Beyeler, C; Banks, R E; Thompson, D; Forbes, M A; Cooper, E H; Bird, H

    1995-07-01

    A double monoclonal immunoradiometric assay specific for bone alkaline phosphatase (BAP) was used to determine whether the raised total alkaline phosphatase (TAP) often found in patients with active rheumatoid arthritis (RA) and ankylosing spondylitis (AS) is derived from bone or liver. Fifty-eight patients with RA were compared to 14 with AS and 14 with non-inflammatory rheumatic diseases (NI). None had clinical liver disease and only one had a slightly elevated aspartate transaminase activity. Elevated BAP concentrations were found in seven patients (5 RA, 1 AS, 1 NI), only two of whom also had abnormal TAP. Abnormal TAP activities were found in only three patients (all RA). BAP did not correlate with disease activity in RA or AS. In contrast, TAP correlated with disease activity (assessed by plasma viscosity) in RA (P < 0.002) and gamma-glutamyl transferase (GGT) also correlated with plasma viscosity in RA (P < 0.01). Both TAP and BAP were significantly correlated with GGT in RA (P < 0.001 and P < 0.02, respectively). These findings are discussed, together with possible reasons for the conflicting nature of some of the observations. PMID:7486797

  20. Advanced inorganic separators for alkaline batteries

    NASA Technical Reports Server (NTRS)

    Sheibley, D. W. (Inventor)

    1982-01-01

    A flexible, porous battery separator comprising a coating applied to a porous, flexible substrate is described. The coating comprises: (1) a thermoplastic rubber-based resin which is insoluble and unreactive in the alkaline electrolyte; (2) a polar organic plasticizer which is reactive with the alkaline electrolyte to produce a reaction product which contains a hydroxyl group and/or a carboxylic acid group; and (3) a mixture of polar particulate filler materials which are unreactive with the electrolyte, the mixture comprising at least one first filler material having a surface area of greater than 25 meters sq/gram, at least one second filler material having a surface area of 10 to 25 sq meters/gram, wherein the volume of the mixture of filler materials is less than 45% of the total volume of the fillers and the binder, the filler surface area per gram of binder is about 20 to 60 sq meters/gram, and the amount of plasticizer is sufficient to coat each filler particle. A method of forming the battery separator is also described.

  1. High temperature filter materials

    SciTech Connect

    Alvin, M.A.; Lippert, T.E.; Bachovchin, D.M.; Tressler, R.E.

    1992-12-01

    Objectives of this program are to identify the potential long-term thermal/chemical effects that advanced coal-based power generating system environments have on the stability of porous ceramic filter materials, as well as to assess the influence of these effects on filter operating performance and life. We have principally focused our efforts on developing an understanding of the stability of the alumina/mullite filter material at high temperature (i.e., 870, 980, and 1100{degrees}C) under oxidizing conditions which contain gas phase alkali species. Testing has typically been performed in two continuous flow-through, high temperature test facilities at the Westinghouse Science and Technology Center, using 7 cm diameter {times} 6.4 mm thick discs. (Alvin, 1992) Each disc of ceramic filter material is exposed for periods of 100 to 3,000 hours in duration. Additional efforts have been performed at Westinghouse to broaden our understanding of the stability of cordierite, cordierite-silicon nitride, reaction and sintered silicon nitride, and clay bonded silicon carbide under similar simulated advanced coal fired process conditions. The results of these efforts are presented in this paper.

  2. High temperature filter materials

    SciTech Connect

    Alvin, M.A.; Lippert, T.E.; Bachovchin, D.M. . Science and Technology Center); Tressler, R.E. )

    1992-01-01

    Objectives of this program are to identify the potential long-term thermal/chemical effects that advanced coal-based power generating system environments have on the stability of porous ceramic filter materials, as well as to assess the influence of these effects on filter operating performance and life. We have principally focused our efforts on developing an understanding of the stability of the alumina/mullite filter material at high temperature (i.e., 870, 980, and 1100[degrees]C) under oxidizing conditions which contain gas phase alkali species. Testing has typically been performed in two continuous flow-through, high temperature test facilities at the Westinghouse Science and Technology Center, using 7 cm diameter [times] 6.4 mm thick discs. (Alvin, 1992) Each disc of ceramic filter material is exposed for periods of 100 to 3,000 hours in duration. Additional efforts have been performed at Westinghouse to broaden our understanding of the stability of cordierite, cordierite-silicon nitride, reaction and sintered silicon nitride, and clay bonded silicon carbide under similar simulated advanced coal fired process conditions. The results of these efforts are presented in this paper.

  3. Digital hum filtering

    USGS Publications Warehouse

    Knapp, R.W.; Anderson, N.L.

    1994-01-01

    Data may be overprinted by a steady-state cyclical noise (hum). Steady-state indicates that the noise is invariant with time; its attributes, frequency, amplitude, and phase, do not change with time. Hum recorded on seismic data usually is powerline noise and associated higher harmonics; leakage from full-waveform rectified cathodic protection devices that contain the odd higher harmonics of powerline frequencies; or vibrational noise from mechanical devices. The fundamental frequency of powerline hum may be removed during data acquisition with the use of notch filters. Unfortunately, notch filters do not discriminate signal and noise, attenuating both. They also distort adjacent frequencies by phase shifting. Finally, they attenuate only the fundamental mode of the powerline noise; higher harmonics and frequencies other than that of powerlines are not removed. Digital notch filters, applied during processing, have many of the same problems as analog filters applied in the field. The method described here removes hum of a particular frequency. Hum attributes are measured by discrete Fourier analysis, and the hum is canceled from the data by subtraction. Errors are slight and the result of the presence of (random) noise in the window or asynchrony of the hum and data sampling. Error is minimized by increasing window size or by resampling to a finer interval. Errors affect the degree of hum attenuation, not the signal. The residual is steady-state hum of the same frequency. ?? 1994.

  4. Multichannel birefringent filter

    NASA Technical Reports Server (NTRS)

    Gouxiang, A.; Huefeng, H.

    1985-01-01

    A birefringent filter with a large field of view and no additional polarization is discussed. It plays an important role in observing the solar monochromatic image and the solar vector magnetic field. It has only one channel. For simultaneous multichannel observations, the solar spectrograph is better than the birefringent filter. A suggestion was proposed to try to obtain a multichannel birefringent filter which will be used in a new telescope at the Huairou reservoir station of Beijing Observatory. By means of N polarizing beam splitters, (N+1) channels can be divided. In principle, any number of limitless channels can be obtained, thereby subdividing the whole solar spectrum. But since the space in a telescope is limited, the channels to be used are also limited. For the new telescope, 5 and 9 channels are being considered, and the spectral range is from lambda 3800A to lambda 7000A. Many lines are included in this range, for example, H, K, H beta, lambda lambda 5324A, 5250A, 6302A, H alpha, etc., and some of the lines are suited to measure solar velocity fields. According to the character of these lines, the half width of each channel is determined. Moreover, in some channels the solid polarizing Michelson interferometer is considered for measuring velocity field with a lm/s accuracy. The advantages of the filter and problems to be solved are listed.

  5. Ozone decomposing filter

    DOEpatents

    Simandl, Ronald F.; Brown, John D.; Whinnery, Jr., LeRoy L.

    1999-01-01

    In an improved ozone decomposing air filter carbon fibers are held together with a carbonized binder in a perforated structure. The structure is made by combining rayon fibers with gelatin, forming the mixture in a mold, freeze-drying, and vacuum baking.

  6. Foam For Filtering

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Like nature's honeycomb, foam is a structure of many-sided cells, apparently solid but actually only three percent material and 97 percent air. Foam is made by a heat-producing chemical reaction which expands a plastic material in a manner somewhat akin to the heat-induced rising of a loaf of bread. The resulting structure of interconnected cells is flexible yet strong and extremely versatile in applicati6n. Foam can, for example, be a sound absorber in one form, while in another it allows sound to pass through it. It can be a very soft powder puff material and at the same time a highly abrasive scrubber. A sampling of foam uses includes stereo speaker grilles, applying postage meter ink, filtering lawnmower carburetor air; deadening noise in trucks and tractors, applying cosmetics, releasing fabric softener and antistatic agents in home clothes dryers, painting, filtering factory heating and ventilating systems, shining shoes, polishing cars, sponge-mopping floors, acting as pre-operative surgical scrubbers-the list is virtually limitless. The process by which foam is made produces "windows," thin plastic membranes connecting the cell walls. Windowed foam is used in many applications but for certain others-filtering, for example-it is desirable to have a completely open network. Scott Paper Company's Foam Division, Chester, Pennsylvania, improved a patented method of "removing the windows," to create an open structure that affords special utility in filtering applications. NASA technology contributed to Scott's improvement.

  7. Rotating drum filter

    DOEpatents

    Anson, Donald

    1990-01-01

    A perforated drum (10) rotates in a coaxial cylindrical housing (18) having three circumferential ports (19,22,23), and an axial outlet (24) at one end. The axis (11) is horizontal. A fibrous filter medium (20) is fed through a port (19) on or near the top of the housing (81) by a distributing mechanism (36) which lays a uniform mat (26) of the desired thickness onto the rotating drum (10). This mat (26) is carried by the drum (10) to a second port (23) through which dirty fluid (13) enters. The fluid (13) passes through the filter (26) and the cleaned stream (16) exits through the open end (15) of the drum (10) and the axial port (24) in the housing (18). The dirty filter material (20) is carried on to a third port (22) near the bottom of the housing (18) and drops into a receiver (31) from which it is continuously removed, cleaned (30), and returned (32) to the charging port (36) at the top. To support the filter mat, the perforated cylinder may carry a series of tines (40), shaped blades (41), or pockets, so that the mat (26) will not fall from the drum (10) prematurely. To minimize risk of mat failure, the fluid inlet port (23) may be located above the horizontal centerline (11).

  8. Ozone decomposing filter

    SciTech Connect

    Simandl, R.F.; Brown, J.D.; Whinnery, L.L. Jr.

    1999-11-02

    In an improved ozone decomposing air filter carbon fibers are held together with a carbonized binder in a perforated structure. The structure is made by combining rayon fibers with gelatin, forming the mixture in a mold, freeze-drying, and vacuum baking.

  9. Compressive Bilateral Filtering.

    PubMed

    Sugimoto, Kenjiro; Kamata, Sei-Ichiro

    2015-11-01

    This paper presents an efficient constant-time bilateral filter that produces a near-optimal performance tradeoff between approximate accuracy and computational complexity without any complicated parameter adjustment, called a compressive bilateral filter (CBLF). The constant-time means that the computational complexity is independent of its filter window size. Although many existing constant-time bilateral filters have been proposed step-by-step to pursue a more efficient performance tradeoff, they have less focused on the optimal tradeoff for their own frameworks. It is important to discuss this question, because it can reveal whether or not a constant-time algorithm still has plenty room for improvements of performance tradeoff. This paper tackles the question from a viewpoint of compressibility and highlights the fact that state-of-the-art algorithms have not yet touched the optimal tradeoff. The CBLF achieves a near-optimal performance tradeoff by two key ideas: 1) an approximate Gaussian range kernel through Fourier analysis and 2) a period length optimization. Experiments demonstrate that the CBLF significantly outperforms state-of-the-art algorithms in terms of approximate accuracy, computational complexity, and usability. PMID:26068315

  10. Counting digital filters

    NASA Technical Reports Server (NTRS)

    Zohar, S. (Inventor)

    1973-01-01

    Several embodiments of a counting digital filter of the non-recursive type are disclosed. In each embodiment two registers, at least one of which is a shift register, are included. The shift register received j sub x-bit data input words bit by bit. The kth data word is represented by the integer.

  11. Filter Component Assessment

    SciTech Connect

    Alvin, M.A.; Lippert, T.E.; Diaz, E.S.; Smeltzer, E.E.

    1996-12-31

    Advanced particulate filtration systems are currently being developed at Westinghouse for use in both coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems. To date, Westinghouse has demonstrated 5855 hours of successful operation of first generation monolithic filter elements in PFBC applications when ash bridging or process thermal transient excursions are avoided. Alternate advanced monolithic and second generation fiber reinforced, filament wound and vacuum infiltrated filters are also being developed which are considered to have enhanced high temperature creep resistance, improved fracture toughness, or enhanced thermal shock characteristics, respectively. Mechanical and component fabrication improvements, as well as degradation mechanisms for each filter element have been identified by Westinghouse during exposure to simulated PFBC operating conditions and alkali-containing steam/air environments. Additional effort is currently being focused on determining the stability of the advanced monolithic high temperature creep resistant clay bonded silicon carbide (SiC) materials, alumina/mullite, and chemically vapor infiltrated (CVI) SiC materials during operation in the Westinghouse Advanced Particulate Filtration (W-APF) system at Foster Wheeler`s pressurized circulating fluidized-bed combustion (PCFBC) test facility in Karhula, Finland. Select advanced filter materials are being defined for additional long-term exposure in integrated gasification combined cycle (IGCC) gas streams. The results of these efforts are summarized in this paper. 6 refs., 7 figs., 11 tabs.

  12. Domain wall filters

    SciTech Connect

    Baer, Oliver; Narayanan, Rajamani; Neuberger, Herbert; Witzel, Oliver

    2007-03-15

    We propose using the extra dimension separating the domain walls carrying lattice quarks of opposite handedness to gradually filter out the ultraviolet fluctuations of the gauge fields that are felt by the fermionic excitations living in the bulk. This generalization of the homogeneous domain wall construction has some theoretical features that seem nontrivial.

  13. Ceramic HEPA Filter Program

    SciTech Connect

    Mitchell, M A; Bergman, W; Haslam, J; Brown, E P; Sawyer, S; Beaulieu, R; Althouse, P; Meike, A

    2012-04-30

    Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.

  14. Expressions of the fundamental equation of gradient elution and a numerical solution of these equations under any gradient profile.

    PubMed

    Nikitas, P; Pappa-Louisi, A

    2005-09-01

    The original work carried out by Freiling and Drake in gradient liquid chromatography is rewritten in the current language of reversed-phase liquid chromatography. This allows for the rigorous derivation of the fundamental equation for gradient elution and the development of two alternative expressions of this equation, one of which is free from the constraint that the holdup time must be constant. In addition, the above derivation results in a very simple numerical solution of the various equations of gradient elution under any gradient profile. The theory was tested using eight catechol-related solutes in mobile phases modified with methanol, acetonitrile, or 2-propanol. It was found to be a satisfactory prediction of solute gradient retention behavior even if we used a simple linear description for the isocratic elution of these solutes. PMID:16131080

  15. The corrosion resistance of thermoset composites in alkaline environments

    SciTech Connect

    Kelley, D.H.; Thompson, M.J.

    1998-12-31

    Corrosion engineers need guidelines for selecting thermoset resins for aggressive applications such as hot alkali and alkaline peroxide. The suitability of fiberglass-reinforced plastic (FRP) for alkaline service depends on factors such as the ester content of the resin, the unsaturated monomer composition, and the cure system. The purpose of the present paper is to show the effect of these factors on the alkaline corrosion resistance of FRP and provide corrosion engineers with the guidance needed for selecting the best epoxy vinyl ester resins for alkaline environments.

  16. Rechargeable Zn-MnO sub 2 alkaline batteries

    SciTech Connect

    Wruck, W.J.; Reichman, B.; Bullock, K.R.; Kao, W.H. )

    1991-12-01

    In this paper progress in the development of rechargeable alkaline zinc-manganese dioxide cells is described. The advantages and limitations of the system are evaluated. Laboratory tests run on commercial primary alkaline cells as well as model simulations of a bipolar MnO{sub 2} electrode show that the rechargeable alkaline battery may be able to compete with lead-acid, nickel-cadmium, and secondary lithium cells for low- to moderate-rate applications. However, because of this poor performance at high rates and low temperatures, the alkaline MnO{sub 2} battery is not suitable for present automotive starting applications.

  17. How do porosity-inducing techniques affect antibiotic elution from bone cement? An in vitro comparison between hydrogen peroxide and a mechanical mixer

    PubMed Central

    Lovric, V.; Leung, A.; Walsh, W. R.

    2008-01-01

    Background Increasing the porosity of an antibiotic-loaded cement spacer increases the antibiotic elution, but the correlation between porosity and antibiotic elution is not well documented. The purposes of this study was to attempt new porosity-increasing methods and to investigate the correlation between antibiotic elution and both total and surface porosity. Materials and methods Five types of antibiotic-loaded bone cement (ALBC) using 2 g cefazolin and 40 g cement were prepared. Other than manual mixing, hydrogen peroxide was used as a foaming agent and a mixing drill piece was used as a mechanical device to try to induce porosity when mixing the cement. Elution of antibiotic into phosphate-buffered saline was measured from 1 h to 1 week. Surface porosity was calculated from density values which were measured with a density kit and an electronic balance, while total porosity was quantified using micro-computed tomography. Results When a mixing drill piece was used to induce porosity, we observed a significant increasin antibiotic elution compared to a manually mixed ALBC. On the other hand, hydrogen peroxide reduced the elution significantly. Mild correlation between the total amount of cluted in 1 week antibiotic elution and total porosity was observed. Conclusions In terms of improving elution, the mixing drill piece seemed to be efficient. A relationship between surface porosity and elution efficacy was not observed. PMID:19384476

  18. INTERIOR VIEW OF FILTER WHEEL MACHINE USED TO FILTER OUT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF FILTER WHEEL MACHINE USED TO FILTER OUT AND SEPARATE BICARBONATE FROM AMMONIONATED BRINE. DISCHARGE FROM STRIPPER COLUMNS (SOLVAY COLUMNS). - Solvay Process Company, SA Wetside Building, Between Willis & Milton Avenue, Solvay, Onondaga County, NY

  19. Filter assembly for metallic and intermetallic tube filters

    DOEpatents

    Alvin, Mary Anne; Lippert, Thomas E.; Bruck, Gerald J.; Smeltzer, Eugene E.

    2001-01-01

    A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.

  20. DEMONSTRATION BULLETIN: COLLOID POLISHING FILTER METHOD - FILTER FLOW TECHNOLOGY, INC.

    EPA Science Inventory

    The Filter Flow Technology, Inc. (FFT) Colloid Polishing Filter Method (CPFM) was tested as a transportable, trailer mounted, system that uses sorption and chemical complexing phenomena to remove heavy metals and nontritium radionuclides from water. Contaminated waters can be pro...

  1. Local Release of Antibiotics for Surgical Site Infection Management Using High-Purity Calcium Sulfate: An In Vitro Elution Study

    PubMed Central

    Cooper, John J.; Florance, Hannah; Robinson, Matthew T.; Michell, Stephen

    2015-01-01

    Abstract Background: The aim of this study was to characterize the elution of four antibiotics from pharmaceutical-grade calcium sulfate beads and show that the eluted antibiotics retained efficacy. Methods: Calcium sulfate was combined with gentamicin, tobramycin, vancomycin, or rifampicin (ratio: 20 g of calcium sulfate, to 240 mg, 500 mg, 900 mg, and 600 mg of antibiotic, respectively). Three grams of beads were immersed in 4 mL of sterile phosphate-buffered saline (PBS) at 37°C. At each time point (4, 8, 24 h; 2, 7, 14, 28, 42 d), eluates were removed for analysis by liquid chromatography–mass spectrometry. The antimicrobial efficacy of antibiotics combined with calcium sulfate beads after 42 d was tested by a modified Kirby-Bauer disc diffusion assay. Results: All samples showed a generally exponential decay in the eluted antibiotic concentration. At the first time point, both gentamicin and tobramycin had eluted to a peak concentration of approximately 10,000 mcg/mL. For rifampicin, the peak concentration occurred at 24 h, whereas for vancomycin, it occurred at 48 h. The eluted concentrations exceeded the minimum inhibitory concentration for common periprosthetic joint infection pathogens for the entire span of the 42 study days. Mass spectrometry confirmed all antibiotics were unchanged when eluted from the calcium sulfate carrier. Antimicrobial efficacy was unaltered after 42 d in combination with calcium sulfate at 37°C. Conclusions: Pharmaceutical-grade calcium sulfate has the potential for targeted local release of tobramycin, gentamicin, vancomycin, and rifampicin over a clinically meaningful time period. PMID:25148101

  2. Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up

    PubMed Central

    Pellegrini, Denise Oliveira; Gomes, Vitor Osório; Lasevitch, Ricardo; Smidt, Luis; Azeredo, Marco Aurélio; Ledur, Priscila; Bodanese, Rodrigo; Sinnott, Leonardo; Moriguchi, Emílio; Caramori, Paulo

    2014-01-01

    Background: Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. Objective: To evaluate the efficacy and safety of drug-eluting stents in the real world. Methods: We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. Results: A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. Conclusion: These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the "real world" may benefit from drug-eluting stenting with excellent, long-term results. PMID:25098375

  3. Effect of alkaline addition on anaerobic sludge digestion with combined pretreatment of alkaline and high pressure homogenization.

    PubMed

    Fang, Wei; Zhang, Panyue; Zhang, Guangming; Jin, Shuguang; Li, Dongyi; Zhang, Meixia; Xu, Xiangzhe

    2014-09-01

    To improve anaerobic digestion efficiency, combination pretreatment of alkaline and high pressure homogenization was applied to pretreat sewage sludge. Effect of alkaline dosage on anaerobic sludge digestion was investigated in detail. SCOD of sludge supernatant significantly increased with the alkaline dosage increase after the combined pretreatment because of sludge disintegration. Organics were significantly degraded after the anaerobic digestion, and the maximal SCOD, TCOD and VS removal was 73.5%, 61.3% and 43.5%, respectively. Cumulative biogas production, methane content in biogas and biogas production rate obviously increased with the alkaline dosage increase. Considering both the biogas production and alkaline dosage, the optimal alkaline dosage was selected as 0.04 mol/L. Relationships between biogas production and sludge disintegration showed that the accumulative biogas was mainly enhanced by the sludge disintegration. The methane yield linearly increased with the DDCOD increase as Methane yield (ml/gVS)=4.66 DDCOD-9.69. PMID:24703958

  4. Transcatheter Arterial Chemoembolization for Liver Cancer: Is It Time to Distinguish Conventional from Drug-Eluting Chemoembolization?

    SciTech Connect

    Liapi, Eleni; Geschwind, Jean-Francois H.

    2011-02-15

    Conventional transcatheter arterial chemoembolization and chemoembolization with drug-eluting beads are increasingly being performed interchangeably in many institutions throughout the world. As both therapies continue to being tested in many phase II and III studies and in combination with other therapies, especially targeted agents, for treatment of primary and metastatic liver cancer, it is imperative to review their current status and evaluate their impact on patient survival. This review critically assesses patient selection, indications, contraindications, techniques, materials, safety, and clinical outcomes of patients treated with conventional chemoembolization and chemoembolization with drug-eluting beads.

  5. OPTIMIZATION OF ADVANCED FILTER SYSTEMS

    SciTech Connect

    R.A. Newby; M.A. Alvin; G.J. Bruck; T.E. Lippert; E.E. Smeltzer; M.E. Stampahar

    2002-06-30

    Two advanced, hot gas, barrier filter system concepts have been proposed by the Siemens Westinghouse Power Corporation to improve the reliability and availability of barrier filter systems in applications such as PFBC and IGCC power generation. The two hot gas, barrier filter system concepts, the inverted candle filter system and the sheet filter system, were the focus of bench-scale testing, data evaluations, and commercial cost evaluations to assess their feasibility as viable barrier filter systems. The program results show that the inverted candle filter system has high potential to be a highly reliable, commercially successful, hot gas, barrier filter system. Some types of thin-walled, standard candle filter elements can be used directly as inverted candle filter elements, and the development of a new type of filter element is not a requirement of this technology. Six types of inverted candle filter elements were procured and assessed in the program in cold flow and high-temperature test campaigns. The thin-walled McDermott 610 CFCC inverted candle filter elements, and the thin-walled Pall iron aluminide inverted candle filter elements are the best candidates for demonstration of the technology. Although the capital cost of the inverted candle filter system is estimated to range from about 0 to 15% greater than the capital cost of the standard candle filter system, the operating cost and life-cycle cost of the inverted candle filter system is expected to be superior to that of the standard candle filter system. Improved hot gas, barrier filter system availability will result in improved overall power plant economics. The inverted candle filter system is recommended for continued development through larger-scale testing in a coal-fueled test facility, and inverted candle containment equipment has been fabricated and shipped to a gasifier development site for potential future testing. Two types of sheet filter elements were procured and assessed in the program

  6. Characterization of polypropylene–polyethylene blends by temperature rising elution and crystallization analysis fractionation

    PubMed Central

    del Hierro, Pilar

    2010-01-01

    The introduction of single-site catalysts in the polyolefins industry opens new routes to design resins with improved performance through multicatalyst-multireactor processes. Physical combination of various polyolefin types in a secondary extrusion process is also a common practice to achieve new products with improved properties. The new resins have complex structures, especially in terms of composition distribution, and their characterization is not always an easy task. Techniques like temperature rising elution fractionation (TREF) or crystallization analysis fractionation (CRYSTAF) are currently used to characterize the composition distribution of these resins. It has been shown that certain combinations of polyolefins may result in equivocal results if only TREF or CRYSTAF is used separately for their characterization. PMID:20730530

  7. Elution of human granulocytes from nylon fibers by means of repulsive van der Waals forces.

    PubMed

    Absolom, D R; van Oss, C J; Neumann, A W

    1981-01-01

    A novel method for the isolation of granulocytes from nylon fibers is described. It is modification of filtration leukapheresis based on cellular surface thermodynamics. The system takes into account both electrical and van der Waals forces. The elution buffer contains a chelating agent and a surface active agent which lowers the surface tension of the liquid to a value intermediate between that of the surface tensions of the nylon fibers and of the granulocytes. Thus, the attractive van der Waals interaction between the fibers and the granulocytes becomes a repulsion. This results in a two- to threefold increase in cell yield. Phagocytosis, candicidal activity, and oxygen consumption did not appear to be affected through the isolation procedure. By both light and transmission electron microscopy the isolated granulocytes appeared to be morphologically intact. PMID:7314214

  8. Hydrogen sulfide production by sulfate-reducing bacteria utilizing additives eluted from plastic resins.

    PubMed

    Tsuchida, Daisuke; Kajihara, Yusuke; Shimidzu, Nobuhiro; Hamamura, Kengo; Nagase, Makoto

    2011-06-01

    In the present study it was demonstrated that organic additives eluted from plastic resins could be utilized as substrates by sulfate-reducing bacteria. Two laboratory-scale experiments, a microcosm experiment and a leaching experiment, were conducted using polyvinyl chloride (PVC) as a model plastic resin. In the former experiment, the conversion of sulfate to sulfide was evident in microcosms that received plasticized PVC as the sole carbon source, but not in those that received PVC homopolymer. Additionally, dissolved organic carbon accumulated only in microcosms that received plasticized PVC, indicating that the dissolved organic carbon originated from additives. In the leaching experiment, phenol and bisphenol A were found in the leached solutions. These results suggest that the disposal of waste plastics in inert waste landfills may result in the production of H(2)S. PMID:21135024

  9. Drug-Eluting Nasal Implants: Formulation, Characterization, Clinical Applications and Challenges

    PubMed Central

    Parikh, Ankit; Anand, Utkarshini; Ugwu, Malachy C.; Feridooni, Tiam; Massoud, Emad; Agu, Remigius U.

    2014-01-01

    Chronic inflammation and infection of the nasal sinuses, also referred to as Chronic Rhinosinusitis (CRS), severely affects patients’ quality of life. Adhesions, ostial stenosis, infection and inflammation relapses complicate chronic sinusitis treatment strategies. Drug-eluting stents, packings or implants have been suggested as reasonable alternatives for addressing these concerns. This article reviewed potential drug candidates for nasal implants, formulation methods/optimization and characterization methods. Clinical applications and important considerations were also addressed. Clinically-approved implants (Propel™ implant, the Relieva stratus™ MicroFlow spacer, and the Sinu-Foam™ spacer) for CRS treatment was an important focus. The advantages and limitations, as well as future considerations, challenges and the need for additional research in the field of nasal drug implant development, were discussed. PMID:24871904

  10. The electrode-tissue interface: the revolutionary role of steroid-elution.

    PubMed

    Mond, Harry G; Helland, John R; Stokes, Kenneth; Bornzin, Gene A; McVenes, Rick

    2014-09-01

    The electrode-tissue interface is that area lying between the cathode of a low-voltage implantable pacemaker or cardioverter-defibrillator (ICD) lead and the endocardium or epi-myocardium of the cardiac chamber being paced. The electrical stimulus that is delivered to this interface is responsible for myocyte depolarization with consequent cardiac contraction. The process by which this occurs is reasonably well understood and any explanation requires a basic understanding of the physics and cellular electrophysiology of pacing. The effective and efficient delivery of electrical energy to the myocardium via the lead is dependent on many factors to be discussed in this review. However, despite numerous evolutionary changes occurring in the cathode's material, design, and surface configuration, it was not until the incorporation of steroid-elution to the electrode-tissue interface that reliable and significantly low stimulation threshold cardiac pacing became possible. PMID:25130977

  11. Experimental characterization of the transport phenomena, adsorption, and elution in a protein A affinity monolithic medium.

    PubMed

    Herigstad, M Omon; Dimartino, Simone; Boi, Cristiana; Sarti, Giulio C

    2015-08-14

    A commercially available convective interaction media (CIM) Protein A monolithic column was fully characterized in view of its application for the affinity capture of IgG in monoclonal antibody production processes. By means of moment analysis, the interstitial porosity and axial dispersion coefficient were determined. The frontal analysis method of characteristic points was employed, for the first time with monolithic media, to determine the dynamic binding capacity. The effects of the flow rate and pH on the total recovery of polyclonal IgG and elution profile were evaluated. A comparison with literature data for Protein A chromatography beads demonstrate the superior bed utilization of monolithic media, which gave better performance at lower residence times. PMID:26143608

  12. Complete fracture and restenosis of sirolimus-eluting stent in ostial saphenous vein graft.

    PubMed

    Ohgo, Takeshi; Otsuka, Yoritaka; Furuno, Takashi

    2008-08-29

    Although the use of a sirolimus-eluting stents (SES) have markedly reduced neointimal proliferation, in-stent restenosis still occurs in some cases. SES fracture was recently suggested as a new potential mechanism of restenosis. We described a rare case of complete SES fracture combined with significant restenosis, due to failure of drug delivery to the vessel wall, in the ostial saphenous vein graft (SVG). The curvature of the SVG during cardiac contractions with perivascular adhesion and fibrosis in the limited intra-thoracic space may induce high mechanical stresses at the ostial SVG. The cause of complete SES fracture in the present case was most likely mechanical stresses resulting from cardiac contractions. PMID:17761313

  13. Drug-eluting nasal implants: formulation, characterization, clinical applications and challenges.

    PubMed

    Parikh, Ankit; Anand, Utkarshini; Ugwu, Malachy C; Feridooni, Tiam; Massoud, Emad; Agu, Remigius U

    2014-01-01

    Chronic inflammation and infection of the nasal sinuses, also referred to as Chronic Rhinosinusitis (CRS), severely affects patients' quality of life. Adhesions, ostial stenosis, infection and inflammation relapses complicate chronic sinusitis treatment strategies. Drug-eluting stents, packings or implants have been suggested as reasonable alternatives for addressing these concerns. This article reviewed potential drug candidates for nasal implants, formulation methods/optimization and characterization methods. Clinical applications and important considerations were also addressed. Clinically-approved implants (Propel™ implant, the Relieva stratus™ MicroFlow spacer, and the Sinu-Foam™ spacer) for CRS treatment was an important focus. The advantages and limitations, as well as future considerations, challenges and the need for additional research in the field of nasal drug implant development, were discussed. PMID:24871904

  14. MRI Visible Drug Eluting Magnetic Microspheres for Transcatheter Intra-Arterial Delivery to Liver Tumors

    PubMed Central

    Kim, Dong-Hyun; Chen, Jeane; Omary, Reed A.; Larson, Andrew C.

    2015-01-01

    Magnetic resonance imaging (MRI)-visible amonafide-eluting alginate microspheres were developed for targeted arterial-infusion chemotherapy. These alginate microspheres were synthesized using a highly efficient microfluidic gelation process. The microspheres included magnetic clusters formed by USPIO nanoparticles to permit MRI and a sustained drug-release profile. The biocompatibility, MR imaging properties and amonafide release kinetics of these microspheres were investigated during in vitro studies. A xenograft rodent model was used to demonstrate the feasibility to deliver these microspheres to liver tumors using hepatic transcatheter intra-arterial infusions and potential to visualize the intra-hepatic delivery of these microspheres to both liver tumor and normal tissues with MRI immediately after infusion. This approach offer the potential for catheter-directed drug delivery to liver tumors for reduced systemic toxicity and superior therapeutic outcomes. PMID:25767615

  15. Irinotecan drug eluting beads used as a treatment of advanced intra hepatic cholangiocarcinoma.

    PubMed

    Roch, Jean Amede; Palma-Gutierrez, John; Lapalus, Marie Georges; Paillet, Carole; Pilleul, Frank

    2008-01-01

    This report describes a 74-year-old male with unresectable intrahepatic cholangiocarcinoma (ICC). However surgical procedure is the only curative treatment, it often seems to be ineffective because of the aggressive behaviour of the disease. The role of systemic chemotherapy in the ICC is undefined with a median survival between 6.43 to 12.17 months obtained by using the combination chemotherapy of gemcitabine with cisplatin. In the present case, we performed a targeted treatment using drug eluting beads (DEB) with irinotecan (IRI) administered as transarterial-chemoembolization (TACE). After one session, the tumour vascularity decreased significantly at the one month evaluation on computed tomography (CT) scan of the liver. This case report suggested that minimally invasive transcatheter DEB embolization could be a promising, safe and effective treatment for selective patients with unresectable ICC. PMID:22470601

  16. The use of bivalirudin to prevent subacute thrombosis during drug-eluting stent implantation.

    PubMed

    Medina, Roberto P; Foto, Denise

    2004-05-01

    Subacute thrombosis is an infrequent but potentially life-threatening complication of percutaneous coronary intervention (PCI) that has received much attention in association with drug-eluting stent (DES) deployment. We performed a retrospective case record review of 186 patients receiving PCI with DES placement at our facility. Patients received either bivalirudin (n=115) or heparin (n=71) as the foundation anticoagulant, with additional antiplatelet therapy as warranted. Two subacute thrombosis complications occurred and are described in detail. There were no deaths, major bleeding episodes or other significant complications. We report our findings and conclude that the addition of a glycoprotein IIb/IIIa inhibitor does not eliminate the risk of subacute thrombosis and that bivalirudin appears to provide effective anticoagulation for patients undergoing PCI with placement of a DES. PMID:15152125

  17. Coronary Stent Thrombosis: Current Insights into New Drug-Eluting Stent Designs

    PubMed Central

    Kim, Hyun Kuk

    2012-01-01

    The advances of interventional cardiology have been achieved by new device development, finding appropriate drug regimes, and understanding of pathomechanism. Drug-eluting stents (DES) implantation with dual anti-platelet therapy reduced revascularization without increasing mortality or myocardial infarction compared with bare-metal stenting. However, late-term stent thrombosis (ST) and restenosis limited its value and raised the safety concern. Main mechanisms of this phenomenon are impaired endothelialization and hypersensitivity reaction with polymer. The second generation DES further improved safety and/or efficacy by using thinner stent strut and biocompatible polymer. Recently, new concept DES with biodegradable polymer, polymer-free and bioabsorbable scaffold are under investigation in the quest to minimize the risk of ST. PMID:23323218

  18. Smooth muscle-specific drug targets for next generation Drug-eluting stent

    PubMed Central

    Tang, Rui; Chen, Shiyou

    2015-01-01

    The occurrence of stent thrombosis is one of the major obstacles limiting the long-term clinical efficacy of percutaneous coronary intervention. The anti-smooth muscle proliferation drugs coated on drug-eluting stents (DES) often indistinguishably block re-endothelialization, an essential step toward successful vascular repair, due to their non-specific effect on endothelial cells (EC). Therefore, identification of therapeutic targets that differentially regulate vascular smooth muscle cell (VSMC) and EC proliferation may lead to the development of ideal drugs for next generation DES. Our recent studies have shown that CTP synthase 1 (CTPS1) differentially regulates the proliferation of VSMC and EC following vascular injury. Therefore, CTPS1 inhibitors are promising agents for DES. In addition to CTPS1, other factors have also shown cell-specific effects on VSMC and/or EC proliferation and thus may become potential molecular targets for developing drugs to coat stents. PMID:24325297

  19. Silica xerogel-chitosan nano-hybrids for use as drug eluting bone replacement.

    PubMed

    Lee, Eun-Jung; Jun, Shin-Hee; Kim, Hyoun-Ee; Kim, Hae-Won; Koh, Young-Hag; Jang, Jun-Hyeog

    2010-01-01

    Silica xerogel-chitosan hybrids containing vancomycin were fabricated by the sol-gel process at room temperature and their potential as a drug eluting bone replacement was evaluated in terms of their mechanical properties and drug release behaviors. Regardless of the content of chitosan, all of the prepared hybrids had a uniform mesoporous structure, which would allow the effectual loading of vancomycin. As the content of chitosan was increased, the strength, strain to failure, and work of fracture of the hybrids were significantly enhanced, while the elastic modulus was decreased. These changes in the mechanical properties were mainly attributed to the mitigation of the brittleness of the silica xerogel through its hybridization with the flexible chitosan phase. In addition, the initial burst-effect was remarkably reduced by increasing the content of chitosan. The hybrids with more than 30% chitosan could release the vancomycin for an extended period of time in a controlled manner. PMID:19657594

  20. Use of paclitaxel-eluting balloons for endotherapy of anastomotic strictures following liver transplantation.

    PubMed

    Kabar, I; Cicinnati, V R; Beckebaum, S; Cordesmeyer, S; Avsar, Y; Reinecke, H; Schmidt, H H

    2012-12-01

    Biliary anastomotic strictures after liver transplantation are a major source of morbidity and graft failure; however, repeated endoscopic therapy has shown variable long-term success rates. Thus the aim of this prospective case series was to evaluate the safety and efficacy of using paclitaxel-eluting balloons in 13 patients requiring treatment for symptomatic anastomotic strictures following liver transplantation. Sustained clinical success-defined as no need for further endoscopic intervention for at least 6 months - was achieved in 12 /13 patients (92 %). One, two, and three interventions were required in 9 (69 %), 1, and 2 patients, respectively (mean number of sessions was 1.46). Mean (± SD) bilirubin level dropped from 6.8 (± 4.1) mg/dL to 1.4 (± 0.9) mg/dL. These promising results justify carrying out a randomized comparative trial to confirm this innovative approach. PMID:23188664

  1. Dolomite Dissolution in Alkaline Cementious Media

    NASA Astrophysics Data System (ADS)

    Mittermayr, Florian; Klammer, Dietmar; Köhler, Stephan; Dietzel, Martin

    2010-05-01

    Chemical alteration of concrete has gained much attention over the past years as many cases of deterioration due to sulphate attack, thaumasite formation (TSA) or alkali silica reactions (ASR) have been reported in various constructions (Schmidt et al, 2009). Much less is known about the so called alkali carbonate reaction (ACR). It is believed that dolomite aggregates can react with the alkalis from the cement, dissolve and form calcite and brucite (Katayama, 2004). Due to very low solubility of dolomite in alkaline solutions this reaction seems doubtful. In this study we are trying to gain new insides about the conditions that can lead to the dissolution of dolomite in concrete. Therefore we investigated concrete samples from Austrian tunnels that show partially dissolved dolomite aggregates. Petrological analysis such as microprobe, SEM and Raman spectroscopy as well as a hydrochemical analysis of interstitial solutions and ground water and modelling with PhreeqC (Parkhurst and Appelo, 1999) are carried out. In addition a series of batch experiments is set up. Modelling approaches by PhreeqC show a thermodynamically possibility in the alkaline range when additional Ca2+ in solution causes dolomite to become more and more undersaturated as calcite gets supersaturated. Interacting ground water is enriched in Ca2+and saturated with respect to gypsum as marine evaporites are found in situ rocks. Furthermore it is more likely that Portlandite (Ca(OH)2) plays a more important role than Na and K in the cement. Portlandite acts as an additional Ca2+ source and is much more abundant than the alkalies. Some interstitial solutions are dominated mainly by Na+ and SO42- and reach concentrations up to 30 g/l TDS. It is believed that solutions can even reach thenardite saturation as efflorescences are found on the tunnel walls. In consequence dolomite solubility increases with increasing ionic strength. pH > 11 further accelerate the process of dedolomitization by the removal

  2. Chemoembolization (TACE) of Unresectable Intrahepatic Cholangiocarcinoma with Slow-Release Doxorubicin-Eluting Beads: Preliminary Results

    SciTech Connect

    Aliberti, Camillo; Benea, Giorgio Tilli, Massimo; Fiorentini, Giammaria

    2008-09-15

    The purpose of this study was to evaluate the safety and efficacy of TACE with microspheres preloaded with doxorubicin in unresectable intrahepatic cholangiocarcinoma (UCH). Twenty patients with UCH were observed; 9 refused, preferring other palliative care or chemotherapy, and 11 agreed to be treated with one or more cycles of DC beads loaded with doxorubicin (100-150 mg) in a TACE procedure between February 2006 and September 2007. A total of 29 individual TACE procedures were performed. Follow-up imaging was performed on all patients before, immediately after, and 4 weeks after each TACE procedure to evaluate the response and need for further treatment. Each patient received i.v hydration, antibiotics, and medications against nausea and pain before TACE. Survival rate was calculated using Kaplan-Meier survival curve. A response rate of 100% followed RECIST criteria was observed. Eight of eleven patients are alive, with a median survival of 13 months. TACE was well tolerated by all patients. One patient developed hepatic abscess requiring antibiotic therapy. No evidence of marrow toxicity has been reported. Only one of nine patients treated with chemotherapy or palliative care is alive (with a median survival of 7 months in this group of patients). In conclusion, we suggest that doxorubicin-eluting beads TACE is a feasible and effective treatment in patients with UCH. Survival seems to be clearly prolonged in the treated group with respect to the palliative group. We consider that doxorubicin-eluting beads TACE of 100-150 mg may be an appropriate palliative therapy for these patients. Further studies are warranted to confirm these interesting preliminary data.

  3. Adding functionality with additive manufacturing: Fabrication of titanium-based antibiotic eluting implants.

    PubMed

    Cox, Sophie C; Jamshidi, Parastoo; Eisenstein, Neil M; Webber, Mark A; Hassanin, Hany; Attallah, Moataz M; Shepherd, Duncan E T; Addison, Owen; Grover, Liam M

    2016-07-01

    Additive manufacturing technologies have been utilised in healthcare to create patient-specific implants. This study demonstrates the potential to add new implant functionality by further exploiting the design flexibility of these technologies. Selective laser melting was used to manufacture titanium-based (Ti-6Al-4V) implants containing a reservoir. Pore channels, connecting the implant surface to the reservoir, were incorporated to facilitate antibiotic delivery. An injectable brushite, calcium phosphate cement, was formulated as a carrier vehicle for gentamicin. Incorporation of the antibiotic significantly (p=0.01) improved the compressive strength (5.8±0.7MPa) of the cement compared to non-antibiotic samples. The controlled release of gentamicin sulphate from the calcium phosphate cement injected into the implant reservoir was demonstrated in short term elution studies using ultraviolet-visible spectroscopy. Orientation of the implant pore channels were shown, using micro-computed tomography, to impact design reproducibility and the back-pressure generated during cement injection which ultimately altered porosity. The amount of antibiotic released from all implant designs over a 6hour period (<28% of the total amount) were found to exceed the minimum inhibitory concentrations of Staphylococcus aureus (16μg/mL) and Staphylococcus epidermidis (1μg/mL); two bacterial species commonly associated with periprosthetic infections. Antibacterial efficacy was confirmed against both bacterial cultures using an agar diffusion assay. Interestingly, pore channel orientation was shown to influence the directionality of inhibition zones. Promisingly, this work demonstrates the potential to additively manufacture a titanium-based antibiotic eluting implant, which is an attractive alternative to current treatment strategies of periprosthetic infections. PMID:27127071

  4. DMSO inhibits human platelet activation through cyclooxygenase-1 inhibition. A novel agent for drug eluting stents?

    SciTech Connect

    Asmis, Lars; Tanner, Felix C.; Sudano, Isabella; Luescher, Thomas F.; Camici, Giovanni G.

    2010-01-22

    Background: DMSO is routinely infused together with hematopoietic cells in patients undergoing myeloablative therapy and was recently found to inhibit smooth muscle cells proliferation and arterial thrombus formation in the mouse by preventing tissue factor (TF), a key activator of the coagulation cascade. This study was designed to investigate whether DMSO prevents platelet activation and thus, whether it may represent an interesting agent to be used on drug eluting stents. Methods and results: Human venous blood from healthy volunteers was collected in citrated tubes and platelet activation was studied by cone and platelet analyzer (CPA) and rapid-platelet-function-assay (RPFA). CPA analysis showed that DMSO-treated platelets exhibit a lower adherence in response to shear stress (-15.54 {+-} 0.9427%, n = 5, P < 0.0001 versus control). Additionally, aggregometry studies revealed that DMSO-treated, arachidonate-stimulated platelets had an increased lag phase (18.0% {+-} 4.031, n = 9, P = 0.0004 versus control) as well as a decreased maximal aggregation (-6.388 {+-} 2.212%, n = 6, P = 0.0162 versus control). Inhibitory action of DMSO could be rescued by exogenous thromboxane A2 and was mediated, at least in part, by COX-1 inhibition. Conclusions: Clinically relevant concentrations of DMSO impair platelet activation by a thromboxane A2-dependent, COX-1-mediated effect. This finding may be crucial for the previously reported anti-thrombotic property displayed by DMSO. Our findings support a role for DMSO as a novel drug to prevent not only proliferation, but also thrombotic complications of drug eluting stents.

  5. Determination of theophylline in serum by molecularly imprinted solid-phase extraction with pulsed elution.

    PubMed

    Mullett, W M; Lai, E P

    1998-09-01

    The technique of molecular imprinting is used to produce an extensively cross-linked poly(methacrylic acid-co-ethylene dimethacrylate) material that contains theophylline as a print molecule. After Soxhlet extraction of the theophylline, binding sites are formed in the polymer with complementary size, shape, and positioning of chemical functionalities. The molecularly imprinted polymer's (MIP) high theophylline selectivity, chemical stability, and physically robust nature make it an ideal stationary-phase material in columns for HPLC separation of theophylline from other structurally related drug compounds. Mobile-phase tests confirm that a retention mechanism typical of normal-phase chromatography governs the separation, and selectivity of the MIP column can be controlled by a combination of the mobile phase and the sample solvent. Under optimal conditions, the MIP column functions like a solid-phase sorbent for theophylline extraction. Rapid elution of the bound theophylline can be accomplished in a pulsed format through injection of 20 μL of a solvent that has the proper polarity and protic nature to disrupt the electrostatic interactions and hydrogen bonding between theophylline and binding sites. A concentration detection limit of 120 ng/mL is obtained using direct UV absorption detection at 270 nm, which corresponds to a mass detection limit of 2.4 ng. This new technique, molecularly imprinted solid-phase extraction with pulsed elution (MISPE-PE), permits on-line preconcentration of theophylline from a large volume of dilute sample solution. Using a sample volume of 300 μL, a 40 ng/mL standard solution produces a detectable peak signal. Application of MISPE-PE in serum analysis further demonstrates the high capability of the MIP column to selectively isolate theophylline from other matrix components for fast, accurate determination. PMID:21644709

  6. Degree of Conversion and BisGMA, TEGDMA, UDMA Elution from Flowable Bulk Fill Composites

    PubMed Central

    Lempel, Edina; Czibulya, Zsuzsanna; Kovács, Bálint; Szalma, József; Tóth, Ákos; Kunsági-Máté, Sándor; Varga, Zoltán; Böddi, Katalin

    2016-01-01

    The degree of conversion (DC) and the released bisphenol A diglycidyl ether dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) monomers of bulk-fill composites compared to that of conventional flowable ones were assessed using micro-Raman spectroscopy and high performance liquid chromatography (HPLC). Four millimeter-thick samples were prepared from SureFil SDR Flow (SDR), X-tra Base (XB), Filtek Bulk Fill (FBF) and two and four millimeter samples from Filtek Ultimate Flow (FUF). They were measured with micro-Raman spectroscopy to determine the DC% of the top and the bottom surfaces. The amount of released monomers in 75% ethanol extraction media was measured with HPLC. The differences between the top and bottom DC% were significant for each material. The mean DC values were in the following order for the bottom surfaces: SDR_4mm_20s > FUF_2mm_20s > XB_4mm_20s > FBF_4mm_20s > XB_4mm_10s > FBF_4mm_10s > FUF_4mm_20s. The highest rate in the amount of released BisGMA and TEGDMA was found from the 4 mm-thick conventional flowable FUF. Among bulk-fills, FBF showed a twenty times higher amount of eluted UDMA and twice more BisGMA; meanwhile, SDR released a significantly higher amount of TEGDMA. SDR bulk-fill showed significantly higher DC%; meanwhile XB, FBF did not reach the same level DC, as that of the 2 mm-thick conventional composite at the bottom surface. Conventional flowable composites showed a higher rate of monomer elution compared to the bulk-fills, except FBF, which showed a high amount of UDMA release. PMID:27213361

  7. Drug deposition in coronary arteries with overlapping drug-eluting stents.

    PubMed

    Rikhtegar, Farhad; Edelman, Elazer R; Olgac, Ufuk; Poulikakos, Dimos; Kurtcuoglu, Vartan

    2016-09-28

    Drug-eluting stents are accepted as mainstream endovascular therapy, yet concerns for their safety may be under-appreciated. While failure from restenosis has dropped to below 5%, the risk of stent thrombosis and associated mortality remain relatively high. Further optimization of drug release is required to minimize thrombosis risk while maintaining therapeutic dose. The complex three-dimensional geometry of deployed stents together with the combination of diffusive and advective drug transport render an intuitive understanding of the situation exceedingly difficult. In situations such as this, computational modeling has proven essential, helping define the limits of efficacy, determine the mode and mechanism of drug release, and identify alternatives to avoid toxicity. A particularly challenging conformation is encountered in coronary arteries with overlapping stents. To study hemodynamics and drug deposition in such vessels we combined high-resolution, multi-scale ex vivo computed tomography with a flow and mass transfer computational model. This approach ensures high geometric fidelity and precise, simultaneous calculation of blood flow velocity, shear stress and drug distribution. Our calculations show that drug uptake by the arterial tissue is dependent both on the patterns of flow disruption near the wall, as well as on the relative positioning of drug-eluting struts. Overlapping stent struts lead to localized peaks of drug concentration that may increase the risk of thrombosis. Such peaks could be avoided by anisotropic stent structure or asymmetric drug release designed to yield homogeneous drug distribution along the coronary artery and, at the least, suggest that these issues need to remain in the forefront of consideration in clinical practice. PMID:27432751

  8. Brachytherapy Application with in situ Dose-painting Administered via Gold-nanoparticle Eluters

    PubMed Central

    Sinha, Neeharika; Cifter, Gizem; Sajo, Erno; Kumar, Rajiv; Sridhar, Srinivas; Nguyen, Paul; Cormack, Robert A; Makrigiorgos, G. Mike; Ngwa, Wilfred

    2014-01-01

    Purpose Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A proposed new strategy for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in-situ release after implantation. This in silico study investigates the intra-tumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials An experimentally determined intra-tumoral diffusion coefficient (D) for 10 nm nanoparticles was employed to estimate D for other sizes using the Stoke-Einstein equation. GNP concentration profiles, obtained using D, were then employed to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel using dose-painting by numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation is carried out as a function of GNP size for clinically applicable low dose rate brachytherapy sources: I-125, Pd-103, Cs-131. Results Results showed that dose enhancement to tumor voxels/sub-volumes during brachytherapy can be customized by varying the sizes of GNP released or eluted from the GBS. For example, using 7 mg/g GNP concentration, significant DEF (> 20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNPs sizes of 2 nm, 5 nm, 10 nm, 20 nm, 30 nm 50 nm, and 80 nm when treating with I-125. Conclusions Analyses show that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. The findings provide a useful reference for further work towards potential development of a new brachytherapy application with in-situ dose-painting administered via gold

  9. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost–utility study

    PubMed Central

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    Objective To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Design Cost–utility analysis of audit based patient subgroups by means of a simple economic model. Setting Tertiary care. Participants 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Main outcome measures Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost–utility ratio and threshold price premium. Results Four factors were identified for patients undergoing elective surgery (n  =  1951) and two for non‐elective surgery (n  =  933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non‐elective surgery group with 9.9% risk). Modelled cost–utility ratios were acceptable for only one group of high risk patients undergoing non‐elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be £112 (US$212, [euro ]162) (sirolimus stents) or £89 (US$167, [euro ]130) (paclitaxel stents). Conclusions At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially. PMID:15831599

  10. My Interventional Drug-Eluting Stent Educational App (MyIDEA): Patient-Centered Design Methodology

    PubMed Central

    Shroff, Adhir; Groo, Vicki; Dickens, Carolyn; Field, Jerry; Baumann, Matthew; Welland, Betty; Gutowski, Gerry; Flores Jr, Jose D; Zhao, Zhongsheng; Bahroos, Neil; Hynes, Denise M; Wilkie, Diana J

    2015-01-01

    Background Patient adherence to medication regimens is critical in most chronic disease treatment plans. This study uses a patient-centered tablet app, “My Interventional Drug-Eluting Stent Educational App (MyIDEA).” This is an educational program designed to improve patient medication adherence. Objective Our goal is to describe the design, methodology, limitations, and results of the MyIDEA tablet app. We created a mobile technology-based patient education app to improve dual antiplatelet therapy adherence in patients who underwent a percutaneous coronary intervention and received a drug-eluting stent. Methods Patient advisers were involved in the development process of MyIDEA from the initial wireframe to the final launch of the product. The program was restructured and redesigned based on the patient advisers’ suggestions as well as those from multidisciplinary team members. To accommodate those with low health literacy, we modified the language and employed attractive color schemes to improve ease of use. We assumed that the target patient population may have little to no experience with electronic tablets, and therefore, we designed the interface to be as intuitive as possible. Results The MyIDEA app has been successfully deployed to a low-health-literate elderly patient population in the hospital setting. A total of 6 patients have interacted with MyIDEA for an average of 17.6 minutes/session. Conclusions Including patient advisers in the early phases of a mobile patient education development process is critical. A number of changes in text order, language, and color schemes occurred to improve ease of use. The MyIDEA program has been successfully deployed to a low-health-literate elderly patient population. Leveraging patient advisers throughout the development process helps to ensure implementation success. PMID:26139587

  11. Chemoembolization (TACE) of unresectable intrahepatic cholangiocarcinoma with slow-release doxorubicin-eluting beads: preliminary results.

    PubMed

    Aliberti, Camillo; Benea, Giorgio; Tilli, Massimo; Fiorentini, Giammaria

    2008-01-01

    The purpose of this study was to evaluate the safety and efficacy of TACE with microspheres preloaded with doxorubicin in unresectable intrahepatic cholangiocarcinoma (UCH). Twenty patients with UCH were observed; 9 refused, preferring other palliative care or chemotherapy, and 11 agreed to be treated with one or more cycles of DC beads loaded with doxorubicin (100-150 mg) in a TACE procedure between February 2006 and September 2007. A total of 29 individual TACE procedures were performed. Follow-up imaging was performed on all patients before, immediately after, and 4 weeks after each TACE procedure to evaluate the response and need for further treatment. Each patient received i.v hydration, antibiotics, and medications against nausea and pain before TACE. Survival rate was calculated using Kaplan-Meier survival curve. A response rate of 100% followed RECIST criteria was observed. Eight of eleven patients are alive, with a median survival of 13 months. TACE was well tolerated by all patients. One patient developed hepatic abscess requiring antibiotic therapy. No evidence of marrow toxicity has been reported. Only one of nine patients treated with chemotherapy or palliative care is alive (with a median survival of 7 months in this group of patients). In conclusion, we suggest that doxorubicin-eluting beads TACE is a feasible and effective treatment in patients with UCH. Survival seems to be clearly prolonged in the treated group with respect to the palliative group. We consider that doxorubicin-eluting beads TACE of 100-150 mg may be an appropriate palliative therapy for these patients. Further studies are warranted to confirm these interesting preliminary data. PMID:18478290

  12. Associations Between Target Lesion Restenosis and Drug-Eluting Balloon Use: An Observational Study.

    PubMed

    Lee, Wei-Chieh; Wu, Chiung-Jen; Chen, Yung-Lung; Chung, Wen-Jung; Hsueh, Shu-Kai; Hang, Chi-Ling; Fang, Chih-Yuan; Fang, Hsiu-Yu

    2016-01-01

    Percutaneous coronary interventions (PCIs) with drug-eluting balloons (DEBs) have emerged as an adjunctive treatment for in-stent restenosis (ISR) lesions. However, recurrent restenosis still occurs following DEB use. Our study aimed to identify the associations of target lesion restenosis following DEB use over a 1-year clinical follow-up.Between November 2011 and May 2014, 246 patients were diagnosed with coronary artery ISR in our hospital. A total of 335 coronary ISR lesions were treated with DEBs. The 1-year patent coronary artery group was defined as those with negative noninvasive examinations and no clinical symptoms, or those with no angiographic restenosis. The 1-year current restenosis group was defined as those with angiographic restenosis. Clinical results were compared between 2 groups. Univariate and multivariate cox regression analyses were performed to identify the associations of target lesion restenosis following DEB use.Patients' average age was 64.96 ± 10.68 years, and 77.2% were men. Non-ST segment elevation myocardial infarction was more frequent as the clinical presentation in the 1-year current restenosis group, whereas stable angina was more frequent in the 1-year patent coronary artery group. The 1-year current restenosis group exhibited higher percentages of comorbidities, including hypertension, diabetes, prior myocardial infarction, heart failure, prior coronary artery bypass grafting, and end-stage renal disease (ESRD). Regardless of ostial ISR or nonostial ISR, the results of drug-eluting stent ISR were worse than those for bare-metal stent ISR. Multivariate analysis revealed that ESRD, and coronary ostial lesion, and the severity of pre-PCI stenosis were independently associated with target lesion restenosis following DEB use (P = 0.020, P = 0.009, P = 0.026, respectively).ESRD, and coronary ostial lesion, and the severity of pre-PCI stenosis were independently associated with recurrent target lesion restenosis

  13. Degree of Conversion and BisGMA, TEGDMA, UDMA Elution from Flowable Bulk Fill Composites.

    PubMed

    Lempel, Edina; Czibulya, Zsuzsanna; Kovács, Bálint; Szalma, József; Tóth, Ákos; Kunsági-Máté, Sándor; Varga, Zoltán; Böddi, Katalin

    2016-01-01

    The degree of conversion (DC) and the released bisphenol A diglycidyl ether dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) monomers of bulk-fill composites compared to that of conventional flowable ones were assessed using micro-Raman spectroscopy and high performance liquid chromatography (HPLC). Four millimeter-thick samples were prepared from SureFil SDR Flow (SDR), X-tra Base (XB), Filtek Bulk Fill (FBF) and two and four millimeter samples from Filtek Ultimate Flow (FUF). They were measured with micro-Raman spectroscopy to determine the DC% of the top and the bottom surfaces. The amount of released monomers in 75% ethanol extraction media was measured with HPLC. The differences between the top and bottom DC% were significant for each material. The mean DC values were in the following order for the bottom surfaces: SDR_4mm_20s > FUF_2mm_20s > XB_4mm_20s > FBF_4mm_20s > XB_4mm_10s > FBF_4mm_10s > FUF_4mm_20s. The highest rate in the amount of released BisGMA and TEGDMA was found from the 4 mm-thick conventional flowable FUF. Among bulk-fills, FBF showed a twenty times higher amount of eluted UDMA and twice more BisGMA; meanwhile, SDR released a significantly higher amount of TEGDMA. SDR bulk-fill showed significantly higher DC%; meanwhile XB, FBF did not reach the same level DC, as that of the 2 mm-thick conventional composite at the bottom surface. Conventional flowable composites showed a higher rate of monomer elution compared to the bulk-fills, except FBF, which showed a high amount of UDMA release. PMID:27213361

  14. Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces.

    PubMed

    Matsuda, Masato; Sato, Mika; Sakata, Hiroki; Ogawa, Takahisa; Yamamoto, Ken-ichiro; Yakushiji, Taiji; Fukuda, Makoto; Miyasaka, Takehiro; Sakai, Kiyotaka

    2008-01-01

    When uremic blood flows through dialyzers during hemodialysis, dialysis membrane surfaces are exposed to shear stress and internal filtration, which may affect the surface characteristics of the dialysis membranes. In the present study, we evaluated changes in the characteristics of membrane surfaces caused by shear stress and internal filtration using blood substitutes: water purified by reverse osmosis and 6.7 wt% dextran70 solution. We focused on the levels of a hydrophilic modifier, polyvinylpyrrolidone (PVP), on the membrane surface measured by attenuated total reflectance Fourier transform infrared spectroscopy. Experiments involving 4 h dialysis, 0-144 h shear-stress loading, and 4 h dead-end filtration were performed using polyester-polymer alloy (PEPA) and polysulfone (PS) membranes. After the dialysis experiments with accompanying internal filtration, average PVP retention on the PEPA membrane surface was 93.7% in all areas, whereas that on the PS membrane surface was 98.9% in all areas. After the shear-stress loading experiments, PVP retention on the PEPA membrane surface decreased as shear-stress loading time and the magnitude of shear stress increased. However, with the PS membrane, PVP retention scarcely changed. After the dead-end filtration experiments, PVP retention decreased in all areas for both PEPA and PS membranes, but PVP retention on the PEPA membrane surface was lower than that on the PS membrane surface. PVP on the PEPA membrane surface was eluted by both shear stress and internal filtration, while that on the PS membrane surface was eluted only by internal filtration. PMID:18836876

  15. Predictors of diffuse-type in-stent restenosis following drug-eluting stent implantation

    PubMed Central

    PARK, CHANG-BUM; PARK, HOON-KI

    2013-01-01

    Diffuse-type in-stent restenosis (ISR) is known to be associated with a higher rate of restenosis than focal-type ISR. Therefore, it is clinically important to identify the determinants of diffuse-type ISR following drug-eluting stent (DES) implantation. We investigated the clinical, procedural and angiographic variables for predicting diffuse-type ISR following DES implantation. A total of 173 ISR lesions in 159 patients (diffuse-type: 61 lesions, focal-type: 112 lesions) following DES implantation from February 2003 to May 2008 were included in this study. Clinical, procedural and quantitative coronary angiographic variables were analyzed to determine predictors of diffuse-type ISR following DES implantation. Univariate analysis showed that the absence of hypertension [odds ratio (OR), 0.493; 95% confidence interval (CI), 1.025–4.103, P=0.042], use of a paclitaxel-eluting stent (PES) (OR, 3.318; 95% CI, 1.730–6.365, P<0.001) and smaller post-stenting minimal luminal diameter (MLD; OR, 0.368, 95% CI, 0.168–0.808, P=0.013) were significantly associated with diffuse-type ISR. However, use of a PES (OR, 3.957; 95% CI, 1.977–7.922, P<0.001) and smaller post-stenting MLD (OR, 0.320; CI, 0.140–0.731, P=0.007) were only independent predictors of diffuse-type ISR by multivariate analysis. Diabetes was not a predictor of diffuse-type ISR. The use of a PES and the post-stenting MLD were related to diffuse-type ISR following DES implantation. PMID:23737904

  16. Active resistance capacitance filter design

    NASA Technical Reports Server (NTRS)

    Kerwin, W. J.

    1970-01-01

    Filters, formed by combinations of distributed RC elements with positive-feedback voltage amplifiers, provide transfer functions similar to those the heavier LC filters ordinarily employ. They also provide signal amplification.

  17. The Magnetic Centrifugal Mass Filter

    SciTech Connect

    Abraham J. Fetterman and Nathaniel J. Fisch

    2011-08-04

    Mass filters using rotating plasmas have been considered for separating nuclear waste and spent nuclear fuel. We propose a new mass filter that utilizes centrifugal and magnetic confinement of ions in a way similar to the asymmetric centrifugal trap. This magnetic centrifugal mass filter is shown to be more proliferation resistant than present technology. This filter is collisional and produces well confined output streams, among other advantages. __________________________________________________

  18. Alkaline pulping of some eucalypts from Sudan.

    PubMed

    Khristova, P; Kordsachia, O; Patt, R; Dafaalla, S

    2006-03-01

    Four eucalypts (Eucalyptus camaldulensis, Eucalyptus microtheca, Eucalyptus tereticornis and Eucalyptus citriodora) grown in Sudan were examined for their suitability for pulping and papermaking with different alkaline methods. Their physical, morphological and chemical characteristics are reported. The pulping trials with E. citriodora and E. tereticornis were carried out using the kraft-AQ, soda-AQ, modified AS/AQ (ASA), ASAM and kraft methods. For the other two species, only the ASAM and the kraft process were applied. ASAM pulping gave the best results in terms of yield, degree of delignification, mechanical and optical pulp properties. The best pulps, obtained in kraft and ASAM cooking of E. citriodora, were bleached to 88% ISO brightness in a totally chlorine free bleaching sequence (OQ1O/PQ2P). The bleached pulps, especially the ASAM pulp, showed good papermaking properties and would be suitable for manufacture of writing and printing grades of paper. PMID:15935655

  19. Alkaline oxide conversion coatings for aluminum alloys

    SciTech Connect

    Buchheit, R.G.

    1996-02-01

    Three related conversion coating methods are described that are based on film formation which occurs when aluminum alloys are exposed to alkaline Li salt solutions. Representative examples of the processing methods, resulting coating structure, composition and morphology are presented. The corrosion resistance of these coatings to aerated 0.5 M NaCl solution has been evaluated as a function of total processing time using electrochemical impedance spectroscopy (EIS). This evaluation shows that excellent corrosion resistance can be uniformly achieved using no more than 20 minutes of process time for 6061-T6. Using current methods a minimum of 80 minutes of process time is required to get marginally acceptable corrosion resistance for 2024-T3. Longer processing times are required to achieve uniformly good corrosion resistance.

  20. Alkaline dechlorination of chlorinated volatile organic compounds

    SciTech Connect

    Gu, B.; Siegrist, R.L.

    1996-06-01

    The vast majority of contaminated sites in the United States and abroad are contaminated with chlorinated volatile organic compounds (VOCs) such as trichloroethylene (TCE), trichloroethane (TCA), and chloroform. These VOCs are mobile and persistent in the subsurface and present serious health risks at trace concentrations. The goal of this project was to develop a new chemical treatment system that can rapidly and effectively degrade chlorinated VOCs. The system is based on our preliminary findings that strong alkalis such as sodium hydroxide (NaOH) can absorb and degrade TCE. The main objectives of this study were to determine the reaction rates between chlorinated VOCs, particularly TCE, and strong alkalis, to elucidate the reaction mechanisms and by-products, to optimize the chemical reactions under various experimental conditions, and to develop a laboratory bench- scale alkaline destruction column that can be used to destroy vapor- phase TCE.

  1. The Alkaline Dissolution Rate of Calcite.

    PubMed

    Colombani, Jean

    2016-07-01

    Due to the widespread presence of calcium carbonate on Earth, several geochemical systems, among which is the global CO2 cycle, are controlled to a large extent by the dissolution and precipitation of this mineral. For this reason, the dissolution of calcite has been thoroughly investigated for decades. Despite this intense activity, a consensual value of the dissolution rate of calcite has not been found yet. We show here that the inconsistency between the reported values stems mainly from the variability of the chemical and hydrodynamic conditions of measurement. The spreading of the values, when compared in identical conditions, is much less than expected and is interpreted in terms of sample surface topography. This analysis leads us to propose benchmark values of the alkaline dissolution rate of calcite compatible with all the published values, and a method to use them in various chemical and hydrodynamic contexts. PMID:27282839

  2. Properties of cathode materials in alkaline cells

    NASA Astrophysics Data System (ADS)

    Salkind, A. J.; McBreen, J.; Freeman, R.; Parkhurst, W. A.

    1984-04-01

    Conventional and new cathode materials in primary and secondary alkaline cells were investigated for stability, structure, electrochemical reversibility and efficiency. Included were various forms of AgO for reserve type silver zinc batteries, a new material - AgNiO2 and several nickel electrodes for nickel cadmium and nickel hydrogen cells for aerospace applications. A comparative study was made of the stability of electroformed and chemically prepared AgO. Stability was correlated with impurities. After the first discharge AgNiO2 can be recharged to the monovalent level. The discharge product is predominantly silver. Plastic bonded nickel electrodes display a second plateau on discharge. Additions of Co(OH)2 largely eliminate this.

  3. Polyvinyl alcohol membranes as alkaline battery separators

    NASA Technical Reports Server (NTRS)

    Sheibley, D. W.; Gonzalez-Sanabria, O.; Manzo, M. A.

    1982-01-01

    Polyvinly alcohol (PVA) cross-linked with aldehyde reagents yields membranes that demonstrate properties that make them suitable for use as alkaline battery separators. Film properties can be controlled by the choice of cross-linker, cross-link density and the method of cross-linking. Three methods of cross-linking and their effects on film properties are discussed. Film properties can also be modified by using a copolymer of vinyl alcohol and acrylic acid as the base for the separator and cross-linking it similarly to the PVA. Fillers can be incorporated into the films to further modify film properties. Results of separator screening tests and cell tests for several variations of PBA films are discussed.

  4. Oxygen electrodes for rechargeable alkaline fuel cells

    NASA Technical Reports Server (NTRS)

    Swette, Larry; Giner, Jose

    1987-01-01

    Electrocatalysts and supports for the positive electrode of moderate temperature single unit rechargeable alkaline fuel cells were investigated and developed. The electrocatalysts are defined as the material with a higher activity for the oxygen electrode reaction than the support. Advanced development will require that the materials be prepared in high surface area forms, and may also entail integration of various candidate materials. Eight candidate support materials and seven electrocatalysts were investigated. Of the 8 support, 3 materials meet the preliminary requirements in terms of electrical conductivity and stability. Emphasis is now on preparing in high surface area form and testing under more severe corrosion stress conditions. Of the 7 electrocatalysts prepared and evaluated, at least 5 materials remain as potential candidates. The major emphasis remains on preparation, physical characterization and electrochemical performance testing.

  5. Development of an alkaline fuel cell subsystem

    NASA Technical Reports Server (NTRS)

    1987-01-01

    A two task program was initiated to develop advanced fuel cell components which could be assembled into an alkaline power section for the Space Station Prototype (SSP) fuel cell subsystem. The first task was to establish a preliminary SSP power section design to be representative of the 200 cell Space Station power section. The second task was to conduct tooling and fabrication trials and fabrication of selected cell stack components. A lightweight, reliable cell stack design suitable for the SSP regenerative fuel cell power plant was completed. The design meets NASA's preliminary requirements for future multikilowatt Space Station missions. Cell stack component fabrication and tooling trials demonstrated cell components of the SSP stack design of the 1.0 sq ft area can be manufactured using techniques and methods previously evaluated and developed.

  6. The Nickel(111)/Alkaline Electrolyte Interface

    NASA Technical Reports Server (NTRS)

    Wang, Kuilong; Chottiner, G. S.; Scherson, D. A.; Reid, Margaret A.

    1991-01-01

    The electrochemical properties of Ni (111) prepared and characterized in ultra high vacuum, UHV, by surface analytical techniques have been examined in alkaline media by cyclic voltammetry using an UHV-electrochemical cell transfer system designed and built in this laboratory. Prior to the transfer, the Ni(111) surfaces were exposed to saturation coverages of CO in UHV in an attempt to protect the surface from possible contamination with other gases during the transfer. Temperature Programmed Desorption, TPD, of CO-dosed Ni (111) surfaces displaying sharp c(4x2), LEED patterns, subsequently exposed to water-saturated Ar at atmospheric pressure in an auxiliary UHV compatible chamber and finally transferred back to the main UHV chamber, yielded CO2 and water as the only detectable products. This indicates that the CO-dosed surfaces react with water and/or bicarbonate and hydroxide as the most likely products. Based on the integration of the TPD peaks, the combined amounts of H2O and CO2 were found to be on the order of a single monolayer. The reacted c(4x2)CO/Ni(111) layer seems to protect the surface from undergoing spontaneous oxidation in strongly alkaline solutions. This was evidenced by the fact that the open circuit potential observed immediately after contact with deaerated 0.1 M KOH was about 0.38 V vs. DHE, drifting slightly towards more negative values prior to initiating the voltametric scans. The average ratio of the integrated charge obtained in the first positive linear scan in the range of 0.35 to 1.5 V vs. DHE (initiated at the open circuit potential) and the first (and subsequent) linear negative scans in the same solution yielded for various independent runs a value of 3.5 +/- 0.3. Coulometric analysis of the cyclic voltammetry curves indicate that the electrochemically formed oxyhydroxide layer involves a charge equivalent to 3.2 +/- 0.4 layers of Ni metal.

  7. Filtered cathodic arc source

    DOEpatents

    Falabella, Steven; Sanders, David M.

    1994-01-01

    A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45.degree. to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles.

  8. Filtered cathodic arc source

    DOEpatents

    Falabella, S.; Sanders, D.M.

    1994-01-18

    A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge is described. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45[degree] to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles. 3 figures.

  9. Filtered cathodic arc source

    SciTech Connect

    Falabella, S.; Sanders, D.M.

    1992-12-31

    Disclosed is a continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45{degrees} to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles.

  10. Drilling fluid filter

    DOEpatents

    Hall, David R.; Fox, Joe; Garner, Kory

    2007-01-23

    A drilling fluid filter for placement within a bore wall of a tubular drill string component comprises a perforated receptacle with an open end and a closed end. A hanger for engagement with the bore wall is mounted at the open end of the perforated receptacle. A mandrel is adjacent and attached to the open end of the perforated receptacle. A linkage connects the mandrel to the hanger. The linkage may be selected from the group consisting of struts, articulated struts and cams. The mandrel operates on the hanger through the linkage to engage and disengage the drilling fluid filter from the tubular drill string component. The mandrel may have a stationary portion comprising a first attachment to the open end of the perforated receptacle and a telescoping adjustable portion comprising a second attachment to the linkage. The mandrel may also comprise a top-hole interface for top-hole equipment.

  11. Dichroic ultraviolet light filters

    NASA Astrophysics Data System (ADS)

    Kocher, Christoph; Weder, Christoph; Smith, Paul

    2003-10-01

    With the intention to produce dichroic filters for use in photoluminescent systems that rely on polarized UV light, we synthesized a number of linear, dichroic dyes, which absorb mainly in the near-UV range of the electromagnetic spectrum. These dyes were designed for compatibility with common thermoplastic polymers such as linear low-density poly(ethylene), poly(ethylene terephthalate), and polyamide-12. Films of these host polymers that consisted of 0.2% by weight of various dichroic UV dyes were produced by common melt-processing schemes. Uniaxial drawing of these films yielded highly dichroic UV filters with dichroic ratios in absorption that in some cases exceeded 100. The fact that these free-standing films display little or no coloration and are environmentally stable makes them useful for various applications that involve generation of polarized UV light.

  12. High frequency integrated MOS filters

    NASA Technical Reports Server (NTRS)

    Peterson, C.

    1990-01-01

    Several techniques exist for implementing integrated MOS filters. These techniques fit into the general categories of sampled and tuned continuous-time filters. Advantages and limitations of each approach are discussed. This paper focuses primarily on the high frequency capabilities of MOS integrated filters.

  13. Drive Diagnostic Filter Wheel Control

    2007-07-17

    DrD Filter Wheel Control is National Instrument's Labview software that drives a Drive Diagnostic filter wheel. The software can drive the filter wheel between each end limit, detect the positive and negative limit and each home position and post the stepper motot values to an Excel spreadsheet. The software can also be used to cycle the assembly between the end limits.

  14. Assessment of ceramic membrane filters

    SciTech Connect

    Ahluwalia, R.K.; Geyer, H.K.; Im, K.H.

    1995-08-01

    The objectives of this project include the development of analytical models for evaluating the fluid mechanics of membrane coated, dead-end ceramic filters, and to determine the effects of thermal and thermo-chemical aging on the material properties of emerging ceramic hot gas filters. A honeycomb cordierite monolith with a thin ceramic coating and a rigid candle filter were evaluated.

  15. Quick-change filter cartridge

    DOEpatents

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  16. BMP FILTERS: UPFLOW VS. DOWNFLOW

    EPA Science Inventory

    Stormwater filters are typically operated in a downflow mode. This research had two objectives: 1) to determine the increased life of a filter operated in an upflow mode, and 2) to determine if the operation of a downflow, mixed-media filter could be modeled using the power equat...

  17. Regenerable particulate filter

    DOEpatents

    Stuecker, John N.; Cesarano, III, Joseph; Miller, James E.

    2009-05-05

    A method of making a three-dimensional lattice structure, such as a filter used to remove particulates from a gas stream, where the physical lattice structure is designed utilizing software simulation from pre-defined mass transfer and flow characteristics and the designed lattice structure is fabricated using a free-form fabrication manufacturing technique, where the periodic lattice structure is comprised of individual geometric elements.

  18. Alkaline cleaner replacement for printed wiring board fabrication

    SciTech Connect

    Goldammer, S.E.; Pemberton, S.E.; Tucker, D.R.

    1997-04-01

    A replacement alkaline cleaning chemistry was qualified for the copper cleaning process used to support printed wiring board fabrication. The copper cleaning process was used to prepare copper surfaces for enhancing the adhesion of dry film photopolymers (photoresists and solder masks) and acrylic adhesives. The alkaline chemistry was used to remove organic contaminates such as fingerprints.

  19. TOTAL ALKALINITY OF SURFACE WATERS OF THE US

    EPA Science Inventory

    This map provides a synoptic illustration of the national patterns of surface water alkalinity in the conterminous United States. Alkalinity is the most readily available measure of the acid-neutralizing capacity of surface waters and provides a reasonable estimate o...

  20. Removal of plutonium and americium from alkaline waste solutions

    DOEpatents

    Schulz, Wallace W.

    1979-01-01

    High salt content, alkaline waste solutions containing plutonium and americium are contacted with a sodium titanate compound to effect removal of the plutonium and americium from the alkaline waste solution onto the sodium titanate and provide an effluent having a radiation level of less than 10 nCi per gram alpha emitters.