Probabilistic pipe fracture evaluations for leak-rate-detection applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, S.; Ghadiali, N.; Paul, D.
1995-04-01
Regulatory Guide 1.45, {open_quotes}Reactor Coolant Pressure Boundary Leakage Detection Systems,{close_quotes} was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, {open_quotes}Leak Before Break Evaluation Procedures{close_quotes} where a margin of 10 on the leak detection limit is used in determining the crackmore » size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break.« less
Hardwick, Lisa M; Nail, Steven L; Jarman, James; Hasler, Kai; Hense, Thomas
2013-10-01
A scientific rationale is proposed for the establishment of acceptance criteria for leak rates in pharmaceutical freeze dryers. A method was developed to determine the quantity of air that could leak into any lyophilizer from the outside while still maintaining Class 100/Grade A microbial conditions. A lyophilizing product is assumed most vulnerable to microbial contamination during secondary drying, when mass transfer of water vapor from product to condenser is minimal. Using the void volume of the dryer, calculated from change in internal pressure when a known volume of air is introduced, and the potential maximum bioburden of the leaked air (based on measured values), calculations can determine the allowable leaked volume of air, the flow rate required to admit that volume in a given time frame, and the pressure rise that would result from the leak over a given testing period. For the dryers in this study, using worst-case air quality conditions, it was determined that a leak resulting in a pressure rise of 0.027 mbar over a 30 min period would allow the dryers to remain in secondary drying conditions for 62 h before the established action level of one colony forming unit for each cubic meter of air space would be reached. Copyright © 2013 Elsevier B.V. All rights reserved.
Using airborne measurements and modelling to determine the leak rate of the Elgin platform in 2012
NASA Astrophysics Data System (ADS)
Mobbs, Stephen D.; Bauguitte, Stephane J.-B.; Wellpott, Axel; O'Shea, Sebastian
2013-04-01
On the 25th March 2012 the French multinational oil and gas company Total reported a gas leak at the Elgin gas field in the North Sea following an operation on well G4 on the wellhead platform. During operations to plug and decommission the well methane leaked out which lead to the evacuation of the platform. Total made immense efforts to quickly stop the leak and on the 16th May 2012 the company announced the successful "Top kill". The UK's National Centre for Atmospheric Science (NCAS) supported the Total response to the leak with flights of the Facility for Airborne Atmospheric Measurements (FAAM) BAe-146 aircraft. Between the 3rd of April and the 4th of May five missions were flown. The FAAM aircraft was equipped with a Fast Greenhouse Gas Analyser (FGGA, Model RMT-200, Los Gatos Research Inc., US) to measure CH4 mixing ratios with an accuracy of 0.07±2.48 ppbv. The measurement strategy used followed closely NOAA's during the Deepwater Horizon (DWH) spill in the Gulf of Mexico in 2010. The basis of the method is to sample the cross-wind structure of the plume at different heights downwind of the source. The measurements were then fitted to a Gaussian dispersion model which allowed the calculation of the leak rate. The first mission was flown on the 30th March 2012 only 5 days after Total reported the leak. On this day maximum CH4 concentrations exceeded 2800 ppbv. The plume was very distinct and narrow especially near the platform (10km) and it showed almost perfect Gaussian characteristics. Further downwind the plume was split up into several filaments. On this day the CH4 leak rate was estimated to be 1.1 kg/s. Between the 1st and 2nd mission (03/04/2012) the leak rate decreased significantly to about 0.5 kg/s. From the 2nd flight onwards only a minor decrease in leak rate was calculated. The last mission - while the platform was still leaking - was flown on the 4th of May, when the leak rate was estimated to be 0.3 kg/s. The FAAM aircraft measurements delivered time-critical, actionable information that accurately quantified the Elgin leak rate and contributed directly to safe and successful operational decision making.
Verification of International Space Station Component Leak Rates by Helium Accumulation Method
NASA Technical Reports Server (NTRS)
Underwood, Steve D.; Smith, Sherry L.
2003-01-01
Discovery of leakage on several International Space Station U.S. Laboratory Module ammonia system quick disconnects (QDs) led to the need for a process to quantify total leakage without removing the QDs from the system. An innovative solution was proposed allowing quantitative leak rate measurement at ambient external pressure without QD removal. The method utilizes a helium mass spectrometer configured in the detector probe mode to determine helium leak rates inside a containment hood installed on the test component. The method was validated through extensive developmental testing. Test results showed the method was viable, accurate and repeatable for a wide range of leak rates. The accumulation method has been accepted by NASA and is currently being used by Boeing Huntsville, Boeing Kennedy Space Center and Boeing Johnson Space Center to test welds and valves and will be used by Alenia to test the Cupola. The method has been used in place of more expensive vacuum chamber testing which requires removing the test component from the system.
Medrinal, C; Prieur, G; Contal, O; Villiot-Danger, E; Doyle, C; Reychler, G; Quieffin, J
2015-05-01
Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects. Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10). The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041). There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.
Assessment of volume and leak measurements during CPAP using a neonatal lung model.
Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G
2008-01-01
Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.
Shields, W.R.
1960-10-18
An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.
Importance of limiting hohlraum leaks at cryogenic temperatures on NIF targets
Bhandarkar, Suhas; Teslich, Nick; Haid, Ben; ...
2017-08-18
Inertial confinement fusion targets are complex systems designed to allow fine control of temperature and pressure for making precise spherical ice layers of hydrogen isotopes at cryogenic temperatures. We discuss the various technical considerations for a maximum leak rate based on heat load considerations. This maximum flow rate turns out to bemore » $$5\\times 10^{-6}$$ standard cc per second, which can be caused by an orifice less than half a micron in diameter. This makes the identification of the location and resolution of the leak a significant challenge. To illustrate this, we showcase one example of a peculiar failure mode that appeared suddenly but persisted whereby target production yield was severely lowered. Identification of the leak source and the root cause requires very careful analysis of multiple thermomechanical aspects to ensure that the end solution is indeed the right remedy and is robust.« less
In situ formation of leak-free polyethylene glycol (PEG) membranes in microfluidic fuel cells.
Ho, W F; Lim, K M; Yang, K-L
2016-11-29
Membraneless microfluidic fuel cells operated under two co-laminar flows often face serious fuel cross-over problems, especially when flow rates are close to zero. In this study, we show that polyethylene glycol (PEG) monomers can be cross-linked inside microfluidic channels to form leak-free PEG membranes, which prevent mixing of two incompatible electrolyte solutions while allowing diffusion of certain molecules (e.g. glucose) and ions. By using PEG monomers of different molecular weights and cross-linking conditions, we are able to tailor selectivity of the membrane to allow passage of glucose while blocking larger molecules such as trypan blue. As a proof of principle, a microfluidic fuel cell with a PEG membrane and two incompatible electrolytes (acid and base) is demonstrated. Thanks to the leak-free nature of the PEG membrane, these two electrolytes do not mix together even at very slow flow rates. This microfluidic fuel cell is able to generate a voltage up to ∼450 mV from 10 mM of glucose with a flow rate of 20 μL min -1 . This microfluidic fuel cell is potentially useful as a miniature power source for many applications.
On the probability of exceeding allowable leak rates through degraded steam generator tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cizelj, L.; Sorsek, I.; Riesch-Oppermann, H.
1997-02-01
This paper discusses some possible ways of predicting the behavior of the total leak rate through the damaged steam generator tubes. This failure mode is of special concern in cases where most through-wall defects may remain In operation. A particular example is the application of alternate (bobbin coil voltage) plugging criterion to Outside Diameter Stress Corrosion Cracking at the tube support plate intersections. It is the authors aim to discuss some possible modeling options that could be applied to solve the problem formulated as: Estimate the probability that the sum of all individual leak rates through degraded tubes exceeds themore » predefined acceptable value. The probabilistic approach is of course aiming at reliable and computationaly bearable estimate of the failure probability. A closed form solution is given for a special case of exponentially distributed individual leak rates. Also, some possibilities for the use of computationaly efficient First and Second Order Reliability Methods (FORM and SORM) are discussed. The first numerical example compares the results of approximate methods with closed form results. SORM in particular shows acceptable agreement. The second numerical example considers a realistic case of NPP in Krsko, Slovenia.« less
Kirsch, L E; Nguyen, L; Moeckly, C S
1997-01-01
The development of mass spectrometry-based leak detection for pharmaceutical container integrity was undertaken to provide an alternative to microbial challenge testing. Standard 10-mL vials were modified to contain pinholes (0.5 to 10 microns) by affixing micropipettes with epoxy into 2-mm vial side wall holes. The absolute leak rate was determined using vials that were sealed in a tracer (helium) environment with butyl rubber stoppers and crimps. Alternatively leak rates were determined using vials that were sealed in room air and exposed to tracer under pressure (charging or bombing). Tracer leak rates were measured with mass spectrometry leak rate detectors. The absolute leak rate was correlated the squared nominal leak radius which suggested that the mode of gas flow through the glass pipette leaks was more turbulent than viscous even at low leak rates typically associated with viscous flow. The minimum observed absolute leak rate was about 10(-6.6) std cc/sec and was likely due to helium permeation through the rubber stoppers. Heat-stressed rubber stoppers did not affect the baseline absolute leak rate. Adsorption of helium tracer to the test unit surfaces was found to confound baseline leak rate measurement reliability but was eliminated as a source of variation by exposing the test units to ambient air for > or = 12 hours. The absolute leak rate and the leak rate measured after charging were related in a mathematically predictable way.
Detecting subsurface fluid leaks in real-time using injection and production rates
NASA Astrophysics Data System (ADS)
Singh, Harpreet; Huerta, Nicolas J.
2017-12-01
CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to detecting the time when a leak is activated and the volume of that leakage, this method provides an insight about the leak location, and reservoir connectivity. We are proposing this as a complementary method that can be used with other, more expensive, methods early on in the injection process. This will allow an operator to conduct more expensive surveys less often because the proposed method can show if there are no leaks on a monthly basis that is cheap and fast.
ISS Ammonia Leak Detection Through X-Ray Fluorescence
NASA Technical Reports Server (NTRS)
Camp, Jordan; Barthelmy, Scott; Skinner, Gerry
2013-01-01
Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.
Effect of ADP on slow-twitch muscle fibres of the rat: implications for muscle fatigue.
Macdonald, W A; Stephenson, D G
2006-05-15
Slow-twitch mechanically skinned fibres from rat soleus muscle were bathed in solutions mimicking the myoplasmic environment but containing different [ADP] (0.1 microm to 1.0 mm). The effect of ADP on sarcoplasmic reticulum (SR) Ca2+-content was determined from the magnitude of caffeine-induced force responses, while temporal changes in SR Ca2+-content allowed determination of the effective rates of the SR Ca2+-pump and of the SR Ca2+-leak. The SR Ca2+-pump rate, estimated at pCa (-log10[Ca2+]) 7.8, was reduced by 20% as the [ADP] was increased from 0.1 to 40 microm, with no further alteration when the [ADP] was increased to 1.0 mm. The SR Ca2+-leak rate constant was not altered by increasing [ADP] from 0.1 to 40 microm, but was increased by 26% when the [ADP] was elevated to 1.0 mm. This ADP-induced SR Ca2+-leak was insensitive to ruthenium red but was abolished by 2,5-di(tert-butyl)-1,4-hydroquinone (TBQ), indicating that the leak pathway is via the SR Ca2+-pump and not the SR Ca2+-release channel. The decrease in SR Ca2+-pump rate and SR Ca2+-leak rate when [ADP] was increased led to a 40% decrease in SR Ca2+-loading capacity. Elevation of [ADP] had only minor direct effects on the contractile apparatus of slow-twitch fibres. These results suggest that ADP has only limited depressing effects on the contractility of slow-twitch muscle fibres. This is in contrast to the marked effects of ADP on force responses in fast-twitch muscle fibres and may contribute to the fatigue-resistant nature of slow-twitch muscle fibres.
Nanoscale Capillary Flows in Alumina: Testing the Limits of Classical Theory.
Lei, Wenwen; McKenzie, David R
2016-07-21
Anodic aluminum oxide (AAO) membranes have well-formed cylindrical channels, as small as 10 nm in diameter, in a close packed hexagonal array. The channels in AAO membranes simulate very small leaks that may be present for example in an aluminum oxide device encapsulation. The 10 nm alumina channel is the smallest that has been studied to date for its moisture flow properties and provides a stringent test of classical capillary theory. We measure the rate at which moisture penetrates channels with diameters in the range of 10 to 120 nm with moist air present at 1 atm on one side and dry air at the same total pressure on the other. We extend classical theory for water leak rates at high humidities by allowing for variable meniscus curvature at the entrance and show that the extended theory explains why the flow increases greatly when capillary filling occurs and enables the contact angle to be determined. At low humidities our measurements for air-filled channels agree well with theory for the interdiffusive flow of water vapor in air. The flow rate of water-filled channels is one order of magnitude less than expected from classical capillary filling theory and is coincidentally equal to the helium flow rate, validating the use of helium leak testing for evaluating moisture flows in aluminum oxide leaks.
Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal
NASA Technical Reports Server (NTRS)
Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.
2011-01-01
Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the experimentally obtained air leak rate data suggest that neither conversion factor can be used alone to accurately convert helium leak rates to equivalent air leak rates for the test seals evaluated in this study; other leak phenomena, including permeation, must also be considered.
Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R
2016-04-19
We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.
Cryogenic Feedthrough Test Rig
NASA Technical Reports Server (NTRS)
Skaff, Antony
2009-01-01
The cryogenic feedthrough test rig (CFTR) allows testing of instrumentation feedthroughs at liquid oxygen and liquid hydrogen temperature and pressure extremes (dangerous process fluid) without actually exposing the feedthrough to a combustible or explosive process fluid. In addition, the helium used (inert gas), with cryogenic heat exchangers, exposes the feedthrough to that environment that allows definitive leak rates of feedthrough by typical industry-standard helium mass spectrometers.
Zimmitti, Giuseppe; Roses, Robert E; Andreou, Andreas; Shindoh, Junichi; Curley, Steven A; Aloia, Thomas A; Vauthey, Jean-Nicolas
2013-01-01
Advances in technique, technology, and perioperative care have allowed for the more frequent performance of complex and extended hepatic resections. The purpose of this study was to determine if this increasing complexity has been accompanied by a rise in liver-related complications. A large prospective single-institution database of patients who underwent hepatic resection was used to identify the incidence of liver-related complications. Liver resections were divided into an early era and a late era with equal number of patients (surgery performed before or after 18 May 2006). Patient characteristics and perioperative factors were compared between the two groups. Between 1997 and 2011, 2,628 hepatic resections were performed, with a 90-day morbidity and mortality rate of 37 and 2 %, respectively. We identified higher rates of repeat hepatectomy (12.2 vs 6.1 %; p < 0.001), two-stage resection (4.0 vs 1 %; p < 0.001), extended right hepatectomy (17.6 vs 14.6 %; p = 0.04), and preoperative portal vein embolization (9.1 vs 5.9 %; p < 0.001) in the late era. The incidence of perihepatic abscess (3.7 vs 2.1 %; p = 0.02) and hemorrhage (0.9 vs 0.3 %; p = 0.045) decreased in the late era and the incidence of hepatic insufficiency (3.1 vs 2.6 %; p = 0.41) remained stable. In contrast, the rate of bile leak increased (5.9 vs 3.7 %; p = 0.011). Independent predictors of bile leak included bile duct resection, extended hepatectomy, repeat hepatectomy, en bloc diaphragmatic resection, and intraoperative transfusion. The complexity of liver surgery has increased over time, with a concomitant increase in bile leak rate. Given the strong association between bile leak and other poor outcomes, the development of novel technical strategies to reduce bile leaks is indicated.
The ISS 2B PVTCS Ammonia Leak: An Operational History
NASA Technical Reports Server (NTRS)
Vareha, Anthony
2014-01-01
In 2006, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B power channel began leaking ammonia at a rate of approximately 1.5lbm/year (out of a starting approximately 53lbm system ammonia mass). Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity during the STS-134 mission. During this mission the system was topped off with ammonia piped over from a separate thermal control system. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. Without these periodic EVAs to refill the 2B coolant system, the channel would eventually leak enough fluid as to risk pump cavitation and system failure, resulting in the loss of the 2B power channel - the most critical of the Space Station's 8 power channels. In mid-2012, the leak rate increased to approximately 5lbm/year. Once discovered, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to a dormant thermal control system not intended to be utilized as anything other than spare components. The purpose of this rerouting of the TCS was to increase system volume and to isolate the photovoltaic radiator, thought to be the likely leak source. This EVA was successfully executed on November 1st, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a totally different radiator than what the system was designed to utilize. Unfortunately, data monitoring over the next several months showed that the isolated radiator was not leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, an EVA was in progress to replace the coolant pump - the only other replaceable leak source. This paper will explore the management of the 2B PVTCS leak from the operations perspective. It will discuss the methodology of performing the STS-134 refill, the considerations and contingency plans which went into the architectural overhaul of the system in 2012, and the unprecedented effort which went into the EVA response to the visible leak of May 2013. In particular the paper will focus on the techniques utilized by flight controllers to monitor the system health and to respond to such instances as the rapid May 2013 leak by putting the electrical system in a safe configuration for loss of cooling, and will use recorded telemetry of these events to describe system response to EVA crew and ground actions. It will discuss the innovative design for redundancy of the integrated truss structure's cooling systems which allowed for this leak to be managed with minimal impact to other ISS operations and electrical services, contrasted against the real unintended operations consequences of utilizing the flexibility of the spacecraft's design in this manner. The paper will discuss how the training of the crew and flight controller personnel has adapted to the changing architecture of the power system and the unpredictable nature of the 2B leak.
Full-Scale System for Quantifying Loads and Leak Rates of Seals for Space Applications
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; Daniels, Christopher C.; Wasowski, Janice L.; Robbie, Malcolm G.; Erker, Arthur H.; Drlik, Gary J.; Mayer, John J.
2010-01-01
NASA is developing advanced space-rated vacuum seals in support of future space exploration missions to low-Earth orbit and other destinations. These seals may be 50 to 60 in. (127 to 152 cm) in diameter and must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air for extended missions to the International Space Station or the Moon. Seal compression loads must be below prescribed limits so as not to overload the mechanisms that compress them during docking or mating, and seal adhesion forces must be low to allow two mated systems to separate when required. NASA Glenn Research Center has developed a new test apparatus to measure leak rates and compression and adhesion loads of candidate full-scale seals under simulated thermal, vacuum, and engagement conditions. Tests can be performed in seal-on-seal or seal-on-flange configurations at temperatures from -76 to 140 F (-60 to 60 C) under operational pressure gradients. Nominal and off-nominal mating conditions (e.g., incomplete seal compression) can also be simulated. This paper describes the main design features of the test apparatus as well as techniques used to overcome some of the design challenges.
Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware
NASA Technical Reports Server (NTRS)
Oravec, Heather Ann; Daniels, Christopher C.; Mather, Janice L.
2017-01-01
As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 kPa. Up to six combinations of upstream and downstream pressures for each differential pressure were compared. For a given differential pressure, the various combinations of upstream and downstream dry air pressures did not significantly affect the leak rate. As expected, the leak rate of the O-ring increased with increasing differential pressure. The results suggested that the current leak test pressure conditions, used to verify spacecraft sealing systems with elastomer seals, produce accurate values even though the boundary conditions do not model the space application.
Experiences with leak rate calculations methods for LBB application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grebner, H.; Kastner, W.; Hoefler, A.
1997-04-01
In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.
Morrical, Bradley D; Goverde, Marcel; Grausse, Jean; Gerwig, Tanja; Vorgrimler, Lothar; Morgen, Rachel; Büttiker, Jean-Pierre
2007-01-01
A direct test method using helium leak detection was developed to determine microbial ingress in parenteral vial/rubber closure systems. The purpose of this study was to establish a direct correlation between the helium leak rate and the presence of ingress when vials were submersed under pressure in a broth of bacteria. Results were obtained for two different types of leaks: microholes that have been laser-drilled into thin metal plates, and thin copper wire that was placed between the rubber closure and the glass vial's sealing surface. The results from the microholes showed that the helium leak rate was a function of the square of the hole diameter and fit well with theoretical calculations. The relationship with the wire gave a far more complex dependence and was not modeled theoretically. Comparison with the microbial challenge showed that for microholes a lower size limit was found to be 2 microm with a corresponding leak rate of 1.4 x 10(-3) mbarl/s. For the fine wire experiment the lower limit was 15-microm wire and a corresponding leak rate of 1.3 x 10(-5) mbarl/s. From these tests a safe, lower limit, leak rate was established.
Factors impacting cerebrospinal fluid leak rates in endoscopic sellar surgery.
Karnezis, Tom T; Baker, Andrew B; Soler, Zachary M; Wise, Sarah K; Rereddy, Shruthi K; Patel, Zara M; Oyesiku, Nelson M; DelGaudio, John M; Hadjipanayis, Constantinos G; Woodworth, Bradford A; Riley, Kristen O; Lee, John; Cusimano, Michael D; Govindaraj, Satish; Psaltis, Alkis; Wormald, Peter John; Santoreneos, Steve; Sindwani, Raj; Trosman, Samuel; Stokken, Janalee K; Woodard, Troy D; Recinos, Pablo F; Vandergrift, W Alexander; Schlosser, Rodney J
2016-11-01
In patients undergoing transnasal endoscopic sellar surgery, an analysis of risk factors and predictors of intraoperative and postoperative cerebrospinal fluid leak (CSF) would provide important prognostic information. A retrospective review of patients undergoing endoscopic sellar surgery for pituitary adenomas or craniopharyngiomas between 2002 and 2014 at 7 international centers was performed. Demographic, comorbidity, and tumor characteristics were evaluated to determine the associations between intraoperative and postoperative CSF leaks. Correlations between reconstructive and CSF diversion techniques were associated with postoperative CSF leak rates. Odds ratios (OR) were identified using a multivariate logistic regression model. Data were collected on 1108 pituitary adenomas and 53 craniopharyngiomas. Overall, 30.1% of patients had an intraoperative leak and 5.9% had a postoperative leak. Preoperative factors associated with increased intraoperative leaks were mild liver disease, craniopharyngioma, and extension into the anterior cranial fossa. In patients with intraoperative CSF leaks, postoperative leaks occurred in 10.3%, with a higher postoperative leak rate in craniopharyngiomas (20.8% vs 5.1% in pituitary adenomas). Once an intraoperative leak occurred, craniopharyngioma (OR = 4.255, p = 0.010) and higher body mass index (BMI) predicted postoperative leak (OR = 1.055, p = 0.010). In patients with an intraoperative leak, the use of septal flaps reduced the occurrence of postoperative leak (OR = 0.431, p = 0.027). Rigid reconstruction and CSF diversion techniques did not impact postoperative leak rates. Intraoperative CSF leaks can occur during endoscopic sellar surgery, especially in larger tumors or craniopharyngiomas. Once an intraoperative leak occurs, risk factors for postoperative leaks include craniopharyngiomas and higher BMI. Use of septal flaps decreases this risk. © 2016 ARS-AAOA, LLC.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Effect of ADP on slow-twitch muscle fibres of the rat: implications for muscle fatigue
Macdonald, W A; Stephenson, D G
2006-01-01
Slow-twitch mechanically skinned fibres from rat soleus muscle were bathed in solutions mimicking the myoplasmic environment but containing different [ADP] (0.1 μm to 1.0 mm). The effect of ADP on sarcoplasmic reticulum (SR) Ca2+-content was determined from the magnitude of caffeine-induced force responses, while temporal changes in SR Ca2+-content allowed determination of the effective rates of the SR Ca2+-pump and of the SR Ca2+-leak. The SR Ca2+-pump rate, estimated at pCa (−log10[Ca2+]) 7.8, was reduced by 20% as the [ADP] was increased from 0.1 to 40 μm, with no further alteration when the [ADP] was increased to 1.0 mm. The SR Ca2+-leak rate constant was not altered by increasing [ADP] from 0.1 to 40 μm, but was increased by 26% when the [ADP] was elevated to 1.0 mm. This ADP-induced SR Ca2+-leak was insensitive to ruthenium red but was abolished by 2,5-di(tert-butyl)-1,4-hydroquinone (TBQ), indicating that the leak pathway is via the SR Ca2+-pump and not the SR Ca2+-release channel. The decrease in SR Ca2+-pump rate and SR Ca2+-leak rate when [ADP] was increased led to a 40% decrease in SR Ca2+-loading capacity. Elevation of [ADP] had only minor direct effects on the contractile apparatus of slow-twitch fibres. These results suggest that ADP has only limited depressing effects on the contractility of slow-twitch muscle fibres. This is in contrast to the marked effects of ADP on force responses in fast-twitch muscle fibres and may contribute to the fatigue-resistant nature of slow-twitch muscle fibres. PMID:16556653
Test Report of Special Form Qualification Testing for the ORNL U ZipCan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Oscar A.
This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less
Prediction of failure pressure and leak rate of stress corrosion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majumdar, S.; Kasza, K.; Park, J. Y.
2002-06-24
An ''equivalent rectangular crack'' approach was employed to predict rupture pressures and leak rates through laboratory generated stress corrosion cracks and steam generator tubes removed from the McGuire Nuclear Station. Specimen flaws were sized by post-test fractography in addition to a pre-test advanced eddy current technique. The predicted and observed test data on rupture and leak rate are compared. In general, the test failure pressures and leak rates are closer to those predicted on the basis of fractography than on nondestructive evaluation (NDE). However, the predictions based on NDE results are encouraging, particularly because they have the potential to determinemore » a more detailed geometry of ligamented cracks, from which failure pressure and leak rate can be more accurately predicted. One test specimen displayed a time-dependent increase of leak rate under constant pressure.« less
Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty
NASA Technical Reports Server (NTRS)
Mather, Janice L.; Taylor, Shawn C.
2015-01-01
In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.
Superfluid helium leak sealant study
NASA Technical Reports Server (NTRS)
Vorreiter, J. W.
1981-01-01
Twenty-one leak specimens were fabricated in the ends of stainless steel and aluminum tubes. Eighteen of these tubes were coated with a copolymer material to seal the leak. The other three specimens were left uncoated and served as control specimens. All 21 tubes were cold shocked in liquid helium 50 times and then the leak rate was measured while the tubes were submerged in superfluid helium at 1.7 K. During the cold shocks two of the coated specimens were mechanically damaged and eliminated from the test program. Of the remaining 16 coated specimens one suffered a total coating failure and resulting high leak rate. Another three of the coated specimens suffered partial coating failures. The leak rates of the uncoated specimens were also measured and reported. The significance of various leak rates is discussed in view of the infrared astronomical satellite (IRAS) Dewar performance.
Vendors unveil one-step fugitive emissions monitoring, management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walter, M.
1995-04-01
An alliance of manufacturers has developed a ``single-source solution`` for fugitive emissions monitoring. The LeakTracker{trademark} system combines barcode scans, and vapor detection and data collection capabilities to help companies comply with leak detection and repair requirements as mandated by the Environmental Protection Agency`s Method 21 guidelines. LeakTracker doubles productivity and helps eliminate human-error factors associated with fugitive emissions monitoring. Two-person teams, clipboard-and-pencil data entry, and manual data transcription are eliminated. By automating the process and integrating all components, a technician can monitor 500 points daily following Method 21 guidelines, compared to about 250 readings per day using other systems. LeakTrackermore » includes a handheld workstation, sampling probe and laser-scan barcode reader that fit in a vest worn by a field technician. The technician points the workstation toward a barcode tag and pulls the trigger, which initiates a barcode read and automatically records the time, date and location. While the detachable probe ``sniffs`` for emissions, an analyzer interface module converts the gas detection signal from analog to digital format, allowing data to be recorded by the workstation. LeakTracker has an accuracy rate of 1 part per million.« less
Leak Rate Performance of Silicone Elastomer O-Rings Contaminated with JSC-1A Lunar Regolith Simulant
NASA Technical Reports Server (NTRS)
Oravec, Heather Ann; Daniels, Christopher C.
2014-01-01
Contamination of spacecraft components with planetary and foreign object debris is a growing concern. Face seals separating the spacecraft cabin from the debris filled environment are particularly susceptible; if the seal becomes contaminated there is potential for decreased performance, mission failure, or catastrophe. In this study, silicone elastomer O-rings were contaminated with JSC- 1A lunar regolith and their leak rate performance was evaluated. The leak rate values of contaminated O-rings at four levels of seal compression were compared to those of as-received, uncontaminated, O-rings. The results showed a drastic increase in leak rate after contamination. JSC-1A contaminated O-rings lead to immeasurably high leak rate values for all levels of compression except complete closure. Additionally, a mechanical method of simulant removal was examined. In general, this method returned the leak rate to as-received values.
NASA Technical Reports Server (NTRS)
Garafolo, Nicholas G.; Daniels, Christopher C.
2011-01-01
A novel docking seal was developed for the main interface seal of NASA s Low Impact Docking System (LIDS). This interface seal was designed to maintain acceptable leak rates while being exposed to the harsh environmental conditions of outer space. In this experimental evaluation, a candidate docking seal assembly called Engineering Development Unit (EDU58) was characterized and evaluated against the Constellation Project leak rate requirement. The EDU58 candidate seal assembly was manufactured from silicone elastomer S0383-70 vacuum molded in a metal retainer ring. Four seal designs were considered with unique characteristic heights. The leak rate performance was characterized through a mass point leak rate method by monitoring gas properties within an internal control volume. The leakage performance of the seals were described herein at representative docking temperatures of -50, +23, and +50 C for all four seal designs. Leak performance was also characterized at 100, 74, and 48 percent of full closure. For all conditions considered, the candidate seal assemblies met the Constellation Project leak rate requirement.
NASA Technical Reports Server (NTRS)
Duhon, D. D.
1975-01-01
The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.
Sensitivities of Soap Solutions in Leak Detection
NASA Technical Reports Server (NTRS)
Stuck, D.; Lam, D. Q.; Daniels, C.
1985-01-01
Document describes method for determining minimum leak rate to which soap-solution leak detectors sensitive. Bubbles formed at smaller leak rates than previously assumed. In addition to presenting test results, document discusses effects of joint-flange configurations, properties of soap solutions, and correlation of test results with earlier data.
NASA Technical Reports Server (NTRS)
Vareha, Anthony N.
2014-01-01
As early as 2004, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B electrical power channel began slowly leaking ammonia overboard. Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity (EVA) during the STS-134 Space Shuttle mission. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. In mid-2012, the leak rate increased from 1.5lbm/year to approximately 5lbm/year. As a result, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to an adjacent dormant thermal control system. This EVA, US EVA 20, was successfully executed on November 1, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a different radiator than what the system was designed to utilize. Data monitoring over the next several months showed that the isolated radiator had not been leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, US EVA 21 was in progress to replace the coolant pump - the only remaining replaceable leak source. This was successful, and telemetry monitoring has shown that indeed the coolant pump was the leak source and was thus isolated from the running 2B PVTCS. This paper will explore the management of the 2B PVTCS leak from the operations perspective.
Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R
1997-01-01
Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.
2015-01-01
An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isozaki, Toshikuni; Shibata, Katsuyuki
1997-04-01
Experimental and computed results applicable to Leak Before Break analysis are presented. The specific area of investigation is the effect of the temperature distribution changes due to wetting of the test pipe near the crack on the increase in the crack opening area and leak rate. Two 12-inch straight pipes subjected to both internal pressure and thermal load, but not to bending load, are modelled. The leak rate was found to be very susceptible to the metal temperature of the piping. In leak rate tests, therefore, it is recommended that temperature distribution be measured precisely for a wide area.
Stapleton, Amanda L; Tyler-Kabara, Elizabeth C; Gardner, Paul A; Snyderman, Carl H; Wang, Eric W
2017-02-01
To determine the risk factors associated with cerebrospinal fluid (CSF) leak following endoscopic endonasal surgery (EES) for pediatric skull base lesions. Retrospective chart review of pediatric patients (ages 1 month to 18 years) treated for skull base lesions with EES from 1999 to 2014. Five pathologies were reviewed: craniopharyngioma, clival chordoma, pituitary adenoma, pituitary carcinoma, and Rathke's cleft cyst. Fisher's exact tests were used to evaluate the different factors to determine which had a statistically higher risk of leading to a post-operative CSF leak. 55 pediatric patients were identified who underwent 70 EES's for tumor resection. Of the 70 surgeries, 47 surgeries had intraoperative CSF leaks that were repaired at the time of surgery. 11 of 47 (23%) surgeries had post-operative CSF leaks that required secondary operative repair. Clival chordomas had the highest CSF leak rate at 36%. There was no statistical difference in leak rate based on the type of reconstruction, although 28% of cases that used a vascularized flap had a post-operative leak, whereas only 9% of those cases not using a vascularized flap had a leak. Post-operative hydrocephalus and perioperative use of a lumbar drain were not significant risk factors. Pediatric patients with an intra-operative CSF leak during EES of the skull base have a high rate of post-operative CSF leaks. Clival chordomas appear to be a particularly high-risk group. The use of vascularized flaps and perioperative lumbar drains did not statistically decrease the rate of post-operative CSF leak. Copyright © 2017 Elsevier B.V. All rights reserved.
Failure Pressure and Leak Rate of Steam Generator Tubes With Stress Corrosion Cracks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majumdar, S.; Kasza, K.; Park, J.Y.
2002-07-01
This paper illustrates the use of an 'equivalent rectangular crack' approach to predict leak rates through laboratory generated stress corrosion cracks. A comparison between predicted and observed test data on rupture and leak rate from laboratory generated stress corrosion cracks are provided. Specimen flaws were sized by post-test fractography in addition to pre-test advanced eddy current technique. The test failure pressures and leak rates are shown to be closer to those predicted on the basis of fractography than on NDE. However, the predictions based on NDE results are encouraging, particularly because they have the potential to determine a more detailedmore » geometry of ligamentous cracks from which more accurate predictions of failure pressure and leak rate can be made in the future. (authors)« less
Predictions of vacuum loss of evacuated vials from initial air leak rates.
Prisco, Michael R; Ochoa, Jorge A; Yardimci, Atif M
2013-08-01
Container closure integrity is a critical factor for maintaining product sterility and stability. Therefore, closure systems (found in vials, syringes, and cartridges) are designed to provide a seal between rubber stoppers and glass containers. To ensure that the contained product has maintained its sterility and stability at the time of deployment, the seal must remain intact within acceptable limits. To this end, a mathematical model has been developed to describe vacuum loss in evacuated drug vials. The model computes equivalent leak diameter corresponding to initial air leak rate as well as vacuum loss as a function of time and vial size. The theory accounts for three flow regimes that may be encountered. Initial leak rates from 10(-8) to 10(3) sccm (standard cubic centimeters per minute) were investigated for vials ranging from 1 to 100 mL. Corresponding leak diameters of 0.25-173 μm were predicted. The time for a vial to lose half of its vacuum, the T50 value, ranged from many years at the lowest leak rates and largest vials, to fractions of a second at the highest leak rates and smallest vials. These results may be used to determine what level of initial vacuum leak is acceptable for a given product. Copyright © 2013 Wiley Periodicals, Inc.
Two-stream Convolutional Neural Network for Methane Emissions Quantification
NASA Astrophysics Data System (ADS)
Wang, J.; Ravikumar, A. P.; McGuire, M.; Bell, C.; Tchapmi, L. P.; Brandt, A. R.
2017-12-01
Methane, a key component of natural gas, has a 25x higher global warming potential than carbon dioxide on a 100-year basis. Accurately monitoring and mitigating methane emissions require cost-effective detection and quantification technologies. Optical gas imaging, one of the most commonly used leak detection technology, adopted by Environmental Protection Agency, cannot estimate leak-sizes. In this work, we harness advances in computer science to allow for rapid and automatic leak quantification. Particularly, we utilize two-stream deep Convolutional Networks (ConvNets) to estimate leak-size by capturing complementary spatial information from still plume frames, and temporal information from plume motion between frames. We build large leak datasets for training and evaluating purposes by collecting about 20 videos (i.e. 397,400 frames) of leaks. The videos were recorded at six distances from the source, covering 10 -60 ft. Leak sources included natural gas well-heads, separators, and tanks. All frames were labeled with a true leak size, which has eight levels ranging from 0 to 140 MCFH. Preliminary analysis shows that two-stream ConvNets provides significant accuracy advantage over single steam ConvNets. Spatial stream ConvNet can achieve an accuracy of 65.2%, by extracting important features, including texture, plume area, and pattern. Temporal stream, fed by the results of optical flow analysis, results in an accuracy of 58.3%. The integration of the two-stream ConvNets gives a combined accuracy of 77.6%. For future work, we will split the training and testing datasets in distinct ways in order to test the generalization of the algorithm for different leak sources. Several analytic metrics, including confusion matrix and visualization of key features, will be used to understand accuracy rates and occurrences of false positives. The quantification algorithm can help to find and fix super-emitters, and improve the cost-effectiveness of leak detection and repair programs.
Peker, Kivanc Derya; Gumusoglu, Alpen Yahya; Seyit, Hakan; Kabuli, Hamit Ahmet; Salik, Aysun Erbahceci; Gonenc, Murat; Kapan, Selin; Alis, Halil
2015-12-01
The presence of postoperative bile leak is the major outcome measure for the assessment of operative success in partial cystectomy for hydatid liver disease. However, the optimal operative strategy to reduce the postoperative bile leak rate is yet to be defined. Medical records of patients who underwent partial cystectomy for hydatid liver disease between January 2013 and January 2015 were reviewed in this retrospective analysis. All patients were managed with a specific operative protocol. The primary outcome measure was the rate of persistent postoperative bile leak. The secondary outcome measures were the morbidity and mortality rate, and the length of hospital stay. Twenty-eight patients were included in the study. Only one patient (3.6 %) developed persistent postoperative bile leak. The overall morbidity and mortality rate was 17.8 and 0 %, respectively. The median length of hospital stay was 5 days. Aggressive preventative surgical measures have led to low persistent bile leak rates with low morbidity and mortality.
Impact of the Surgical Experience on Leak Rate After Laparoscopic Sleeve Gastrectomy.
Noel, Patrick; Nedelcu, Marius; Gagner, Michel
2016-08-01
Laparoscopic sleeve gastrectomy (LSG) has become one of the most commonly performed bariatric procedures, largely due to several advantages it carries over more complex bariatric procedures. LSG is generally considered a straightforward procedure, but one of the major concerns is a staple line leak. The objectives of this study are to evaluate the correlation between surgeon's experience and leak rate and to assess the different risk factors for developing a gastric leak after LSG. Private hospital, France. The analysis of a single surgeon's yearly leak rate since the introduction of LSG for possible risk factors was done. A total of 2012 LSGs were performed in between September, 2005 and December, 2014. Twenty cases (1 %) of gastric leak were recorded. Of these, 17 patients were women (94.4 %) with a mean age of 39.4 years (range 22-61) and mean body mass index (BMI) 41.2 kg/m(2) (range 34.8-57.1). On a yearly basis, the leak rate was 4.8 % (2006), 5.7 % (2007), 0 (2008), 2.6 % (2009), 2 % (2010), 0.8 % (2011), 0.6 % (2012), 0.2 % (2013), and 0 (2014). In the first 1000 cases (group A), there were 18 cases of gastric leak and in the last 1000 cases, there were 800 with GORE® SEAMGUARD® Bioabsorbable Staple Line Reinforcement (group B) 2 cases of gastric leak (p = 0.009). A revisional LSG, 395 patients after gastric banding and 61 patients re-sleeve gastrectomy, was performed in 456 cases (22.7 %). There were 3 cases of leak (0.65 %). There were two deaths. LSG can be performed with a low complication rate. This large series of a single surgeon's experience demonstrated that the leak rate after LSG could be significantly decreased over time with changes in techniques.
Structural and leakage integrity of tubes affected by circumferential cracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernalsteen, P.
1997-02-01
In this paper the author deals with the notion that circumferential cracks are generally considered unacceptable. He argues for the need to differentiate two facets of such cracks: the issue of the size and growth rate of a crack; and the issue of the structural strength and leakage potential of the tube in the presence of the crack. In this paper the author tries to show that the second point is not a major concern for such cracks. The paper presents data on the structural strength or burst pressure characteristics of steam generator tubes derived from models and data basesmore » of experimental work. He also presents a leak rate model, and compares the performance of circumferential and axial cracks as far as burst strength and leak rate. The final conclusion is that subject to improvement in NDE capabilities (sizing, detection, growth), that Steam Generator Defect Specific Management can be used to allow circumferentially degraded tubes to remain in service.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, R.N.; Goodrich, R.W.
1991-03-01
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 {plus_minus} 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 {plus_minus} 0.7, {minus}0.4 {plus_minus} 0.3, and 76 {plus_minus} 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone testmore » facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on {Delta}p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc. 13 refs.« less
Demonstration of rapid and sensitive module leak certification for space station freedom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, R.N.; Goodrich, R.W.
1991-03-01
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 {plus minus} 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 {plus minus} 0.7, {minus}0.4 {plus minus} 0.3, and 76 {plus minus} 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes formore » a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on {Delta}p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc. 13 refs.« less
Demonstration of rapid and sensitive module leak certification for Space Station Freedom
NASA Technical Reports Server (NTRS)
Dietz, R. N.; Goodrich, R. W.
1991-01-01
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 (+ or -) 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 (+ or -) 0.7, -0.4 (+ or -) 0.3, and 76 (+ or -) 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on (Delta)p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc.
Leveraging Social Norms to Improve Leak Resolution Outcomes Across Meter Classes:
NASA Astrophysics Data System (ADS)
Holleran, W.
2016-12-01
Over the past decade, utilities, governments, businesses, and nonprofits have come to realize that more than just financial considerations and information drive behavior. Social and psychological factors also play a significant role in shaping consumers' decisions and behaviors around resource use. Stakeholders have consequently turned their interest to behavioral science, a multidisciplinary field that draws from psychology, sociology, public health, and behavioral economics to explain the complex mechanisms that shape human behavior. When used strategically, behavioral science holds the potential to drive down resource use, drive up profits, and generate measurable gains in conservation and efficiency. WaterSmart will present on how the water sector can employ behavioral science to nudge residential rate-payers to use water more efficiently and help them save money. Utilities can use behavioral science to influence people's reaction to leaks. 5% of Single Family Residential (SFR) metered water use can be attributed to leaks. This value potentially skews even higher for MultiFamily (MF) and Commercial accounts given that it can get lost in the noise of daily consumption. Existing leak detection algorithms in the market are not sophisticated enough to detect leaks for a MF or Commercial property. Leveraging data from utilities on known leak events at MF and Commercial buildings allowed WaterSmart to train a machine learning model to identify key features in the load shape and accurately detect these types of water use events. The outcome of the model is a leak amount and confidence level for each irregular usage event. The model also incorporates record feedback from users on the type of leak event, and the accuracy of the alert. When WaterSmart leverages this data model with social norms messaging, we've been able to improve water demand management for MF and Commercial properties. Experiences from leak detection and resolution in the SFR space will also be discussed.
Transthoracic Anastomotic Leak After Esophagectomy: Current Trends.
Ryan, Carrie E; Paniccia, Alessandro; Meguid, Robert A; McCarter, Martin D
2017-01-01
Leaks from intrathoracic esophagogastric anastomosis are thought to be associated with higher rates of morbidity and mortality than leaks from cervical anastomosis. We challenge this assumption and hypothesize that there is no significant difference in mortality based on the location of the esophagogastric anastomosis. A systematic literature search was conducted using PubMed and Embase databases on all studies published from January 2000 to June 2015, comparing transthoracic (TTE) and transhiatal (THE) esophagectomies. Studies using jejunal or colonic interposition were excluded. Outcomes analyzed were leak rate, leak-associated mortality, overall 30-day mortality, and overall morbidity. Meta-analyses were performed using Mantel-Haenszel statistical analyses on studies reporting leak rates of both approaches. Nominal data are presented as frequency and interquartile range (IQR); measures of the association between treatments and outcomes are presented as odds ratio (OR) with 95 % confidence interval. Twenty-one studies (3 randomized controlled trials) were analyzed comprising of 7167 patients (54 % TTE). TTE approach yields a lower anastomotic leak rate (9.8 %; IQR 6.0-12.2 %) than THE (12 %; IQR 11.6-22.1 %; OR 0.56 [0.34-0.92]), without any significant difference in leak associated mortality (7.1 % TTE vs. 4.6 % THE: OR 1.83 [0.39-8.52]). There was no difference in overall 30-day mortality (3.9 % TTE vs. 4.3 % THE; OR 0.86 [0.66-1.13]) and morbidity (59.0 % TTE vs. 66.6 % THE; OR 0.76 [0.37-1.59]). Based on meta-analysis, TTE is associated with a lower leak rate and does not result in higher morbidity or mortality than THE. The previously assumed higher rate of transthoracic anastomotic leak-associated mortality is overstated, thus supporting surgeon discretion and other factors to influence the choice of thoracic versus cervical anastomosis.
NASA Astrophysics Data System (ADS)
McStay, D.; McIlroy, J.; Forte, A.; Lunney, F.; Greenway, T.; Thabeth, K.; Dean, G.
2005-06-01
A new 2000 m depth rated subsea sensor that can effectively, rapidly and remotely detect leaks of fluorescein dye, leak detection chemicals and hydraulic fluids from underwater structures is reported. The system utilizes ultra-bright LED technology to project a structured beam of light, at a wavelength suitable to excite the fluorescence of the target material, into the water column. The resultant fluorescence is collected and digital signal processing used to extract the intensity. The system is capable of detecting ppm concentrations of fluorescein at a range of 2.5 m in water in real time. The ability to stand-off from subsea structures, while rapidly detecting the chemicals makes the system highly suited to subsea leak inspections with remotely operated vehicles or autonomous underwater vehicles, as it allows the vehicles to be flown quickly and safely over the structure to be inspected. This increases both the speed and effectiveness of the inspection. The remote detection capability is also highly effective for probing complex underwater structures. The system has been successfully used in real subsea survey applications and has been found to be effective, user friendly and to dramatically reduce inspection times and hence costs.
Long-life leak standard assembly
Basford, James A.; Mathis, John E.; Wright, Harlan C.
1982-01-01
The present invention is directed to a portable leak standard assembly which is capable of providing a stream of high-purity reference gas at a virtually constant flow rate over an extensive period of time. The leak assembly comprises a high pressure reservoir coupled to a metal leak valve through a valve-controlled conduit. A reproducible leak valve useful in this assembly is provided by a metal tube crimped with a selected pressure loading for forming an orifice in the tube with this orifice being of a sufficient size to provide the selected flow rate. The leak valve assembly is formed of metal so that it can be "baked-out" in a vacuum furnace to rid the reservoir and attendent components of volatile impurities which reduce the efficiency of the leak standard.
Long-life leak standard assembly. [Patent application
Basford, J.A.; Mathis, J.E.; Wright, H.C.
1980-11-12
The present invention is directed to a portable leak standard assembly which is capable of providing a stream of high-purity reference gas at a virtually constant flow rate over an extensive period of time. The leak assembly comprises a high pressure reservoir coupled to a metal leak valve through a valve-controlled conduit. A reproducible leak valve useful in this assembly is provided by a metal tube crimped with a selected pressure loading for forming an orifice in the tube with this orifice being of a sufficient size to provide the selected flow rate. The leak valve assembly is formed of metal so that it can be baked-out in a vacuum furnace to rid the reservoir and attendent components of volatile impurities which reduce the efficiency of the leak standard.
Measurement of Submerged Oil/Gas Leaks using ROV Video
NASA Astrophysics Data System (ADS)
Shaffer, Franklin; de Vera, Giorgio; Lee, Kenneth; Savas, Ömer
2013-11-01
Drilling for oil or gas in the Gulf of Mexico is increasing rapidly at depths up to three miles. The National Commission on the Deepwater Horizon Oil Leak concluded that inaccurate estimates of the leak rate from the Deepwater Horizon caused an inadequate response and attempts to cap the leak to fail. The first response to a submerged oil/gas leak will be to send a Remotely Operated Vehicle (ROV) down to view the leak. During the response to the Deepwater Horizon crisis, the authors Savas and Shaffer were members of the Flow Rate Technical Group's Plume Team who used ROV video to develop the FRTG's first official estimates of the oil leak rate. Savas and Shaffer developed an approach using the larger, faster jet features (e.g., turbulent eddies, vortices, entrained particles) in the near-field developing zone to measure discharge rates. The authors have since used the Berkeley Tow Tank to test this approach on submerged dye-colored water jets and compressed air jets. Image Correlation Velocimetry has been applied to measure the velocity of visible features. Results from tests in the Berkeley Tow Tank and submerged oil jets in the OHMSETT facility will be presented.
High-sensitivity Leak-testing Method with High-Resolution Integration Technique
NASA Astrophysics Data System (ADS)
Fujiyoshi, Motohiro; Nonomura, Yutaka; Senda, Hidemi
A high-resolution leak-testing method named HR (High-Resolution) Integration Technique has been developed for MEMS (Micro Electro Mechanical Systems) sensors such as a vibrating angular-rate sensor housed in a vacuum package. Procedures of the method to obtain high leak-rate resolution were as follows. A package filled with helium gas was kept in a small accumulation chamber to accumulate helium gas leaking from the package. After the accumulation, the accumulated helium gas was introduced into a mass spectrometer in a short period of time, and the flux of the helium gas was measured by the mass spectrometer as a transient phenomenon. The leak-rate of the package was calculated from the detected transient waveform of the mass spectrometer and the accumulation time of the helium gas in the accumulation chamber. Because the density of the helium gas in the vacuum chamber increased and the accumulated helium gas was measured in a very short period of time with the mass spectrometer, the peak strength of the transient waveform became high and the signal to noise ratio was much improved. The detectable leak-rate resolution of the technique reached 1×10-15 (Pa·m3/s). This resolution is 103 times superior to that of the conventional helium vacuum integration method. The accuracy of the measuring system was verified with a standard helium gas leak source. The results were well matched between theoretical calculation based on the leak-rate of the source and the experimental results within only 2% error.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Byoung Yoon
2014-02-01
Oil leaks were found in wellbores of Caverns 105 and 109 at the Big Hill Strategic Petroleum Reserve site. According to the field observations, two instances of casing damage occurred at the depth of the interbed between the caprock bottom and salt top. A three dimensional finite element model, which contains wellbore element blocks and allows each cavern to be configured individually, is constructed to investigate the wellbore damage mechanism. The model also contains element blocks to represent interface between each lithology and a shear zone to examine the interbed behavior in a realistic manner. The causes of the damagedmore » casing segments are a result of vertical and horizontal movements of the interbed between the caprock and salt dome. The salt top subsides because the volume of caverns below the salt top decrease with time due to salt creep closure, while the caprock subsides at a slower rate because the caprock is thick and stiffer. This discrepancy yields a deformation of the well. The deformed wellbore may fail at some time. An oil leak occurs when the wellbore fails. A possible oil leak date of each well is determined using the equivalent plastic strain failure criterion. A well grading system for a remediation plan is developed based on the predicted leak dates of each wellbore.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Byoung; Herrick, Courtney G.
2015-02-01
Oil leaks were found in wellbores of Caverns 105 and 109 at the Big Hill Strategic Petroleum Reserve site. According to the field observations, two instances of casing damage occurred at the depth of the interbed between the caprock bottom and salt top. A three dimensional finite element model, which contains wellbore element blocks and allows each cavern to be configured individually, is constructed to investigate the wellbore damage mechanism. The model also contains element blocks to represent interface between each lithology and a shear zone to examine the interbed behavior in a realistic manner. The causes of the damagedmore » casing segments are a result of vertical and horizontal movements of the interbed between the caprock and salt dome. The salt top subsides because the volume of caverns below the salt top decrease with time due to salt creep closure, while the caprock subsides at a slower rate because the caprock is thick and stiffer. This discrepancy produces a deformation of the well. The deformed wellbore may fail at some time. An oil leak occurs when the wellbore fails. A possible oil leak date of each well is determined using an equivalent plastic strain failure criterion. A well grading system for a remediation plan is developed based on the predicted leak dates of each wellbore.« less
Mobile natural gas leak surveys indicate that two utilities have high false negative rates
NASA Astrophysics Data System (ADS)
von Fischer, J. C.; Brewer, P. E.; Chamberlain, S.; Gaylord, A.; von Fischer, J.
2016-12-01
In the distribution systems that carry natural gas to consumers, leaks need to be discovered for safety reasons and to reduce greenhouse gas emissions. However, few utilities have adopted newer laser-based technologies that have greater sensitivity and precision, and instead rely on "industry standard" equipment that is far less sensitive. In partnership with the Environmental Defense Fund and Google, we mapped natural gas leaks in the domains of two anonymous utilities (Utility "A" and "B") using high sensitivity Picarro methane analyzers in Google Street View Cars. Surprisingly, when we shared these results with utilities, their survey crews were unable to find most of the leaks that our survey indicated (84% in A and 80% in B). To investigate this phenomenon, our team visited a subset of the leaks in each utility domain (n=32 in A and n=30 in B), and worked alongside utility surveyors to search the leak indication area, using a Los Gatos Research ultraportable methane analyzer to pinpoint leak locations. We found evidence of natural gas leaks at 69% and 68% of the locations in Utilities A and B respectively where survey crews had found nothing. We describe this as a "false negative" rate for the utility because the utility survey falsely indicated that there was no leak at these locations. Of these false negatives, 7% (n=2 of 32 in A, n=2 of 30 in B) were determined to be Grade 1 leaks requiring immediate repair due to high safety risk. Instrument sensitivity appears to explain some of the false negative rates. In particular, use of some industry standard equipment appears to have created a false sense of confidence among utility surveyors that leaks were not present. However, there was also evidence of communication failures and that surveyors did not use optimal approaches in their search. Based on these findings, we suggest that: 1) mobile deployment of high-precision methane analyzers can help find more natural gas leaks, and 2) use of some hand-held survey instruments may lead to higher rates of false negatives in leak survey and 3) there may be room for improvement in leak survey methodologies.
Risk Factors for Gastrointestinal Leak after Bariatric Surgery: MBASQIP Analysis.
Alizadeh, Reza Fazl; Li, Shiri; Inaba, Colette; Penalosa, Patrick; Hinojosa, Marcelo W; Smith, Brian R; Stamos, Michael J; Nguyen, Ninh T
2018-03-30
Gastrointestinal leak remains one of the most dreaded complications in bariatric surgery. We aimed to evaluate risk factors and the impact of common perioperative interventions on the development of leak in patients who underwent laparoscopic bariatric surgery. Using the 2015 database of accredited centers, data were analyzed for patients who underwent laparoscopic sleeve gastrectomy or Roux-en-Y gastric bypass (LRYGB). Emergent, revisional, and converted cases were excluded. Multivariate logistic regression was used to analyze risk factors for leak, including provocative testing of anastomosis, surgical drain placement, and use of postoperative swallow study. Data from 133,478 patients who underwent laparoscopic sleeve gastrectomy (n = 92,495 [69.3%]) and LRYGB (n = 40,983 [30.7%]) were analyzed. Overall leak rate was 0.7% (938 of 133,478). Factors associated with increased risk for leak were oxygen dependency (adjusted odds ratio [AOR] 1.97), hypoalbuminemia (AOR 1.66), sleep apnea (AOR 1.52), hypertension (AOR 1.36), and diabetes (AOR 1.18). Compared with LRYGB, laparoscopic sleeve gastrectomy was associated with a lower risk of leak (AOR 0.52; 95% CI 0.44 to 0.61; p < 0.01). Intraoperative provocative test was performed in 81.9% of cases and the leak rate was higher in patients with vs without a provocative test (0.8% vs 0.4%, respectively; p < 0.01). A surgical drain was placed in 24.5% of cases and the leak rate was higher in patients with vs without a surgical drain placed (1.6% vs 0.4%, respectively; p < 0.01). A swallow study was performed in 41% of cases and the leak rate was similar between patients with vs without swallow study (0.7% vs 0.7%; p = 0.50). The overall rate of gastrointestinal leak in bariatric surgery is low. Certain preoperative factors, procedural type (LRYGB), and interventions (intraoperative provocative test and surgical drain placement) were associated with a higher risk for leaks. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Frank, H. A.; Uchiyama, A. A.
1973-01-01
Water vapor loss rates were determined from simulated and imperfectly sealed alkaline cells in the vacuum environment. The observed rates were found to be in agreement with a semi-empirical equation employed in vacuum technology. Results thereby give support for using this equation for the prediction of loss rates of battery gases and vapors to the aerospace environment. On this basis it was shown how the equation can be applied to the solution of many heretofore unresolved questions regarding leaks in batteries. Among these are the maximum permissible leak size consistent with a given cell life or conversely the maximum life consistent with a given leak size. It was also shown that loss rates of these cells in the terrestrial environment are several orders of magnitude less than the corresponding loss rates in the aerospace environment.
78 FR 37133 - National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-20
... systems that would allow owners and operators at existing sources to monitor quarterly using a leak action... option, which requires monitoring monthly at a leak action level defined as a total strippable... monitoring alternative and the modeling indicates that quarterly monitoring at the lower leak action level...
[Management of cerebrospinal fluid leaks according to size. Our experience].
Alobid, Isam; Enseñat, Joaquim; Rioja, Elena; Enriquez, Karla; Viscovich, Liza; de Notaris, Matteo; Bernal-Sprekelsen, Manuel
2014-01-01
We present our experience in the reconstruction of cerebrospinal fluid (CSF) leaks according to their size and location. Fifty-four patients who underwent advanced skull base surgery (large defects) and 62 patients with CSF leaks of different origin (small and medium-sized defects) were included. Large defects were reconstructed with a nasoseptal pedicled flap positioned on fat and fascia lata and lumbar drainage was used. In small and medium-sized leaks of other origin, intrathecal fluorescein 5% was applied previously to identify the defect. Fascia lata in an underlay position was used for reconstruction, which was then covered with mucoperiosteum from the turbinate. Perioperative antibiotics were administered for 5-7 days. Nasal packing was removed after 24-48 hours. The most frequent aetiology for small and medium-sized defects was spontaneous (48.4%), followed by trauma (24.2%), iatrogenic (5%) and others. The success rate was of 91% after the first surgery and 98% in large skull base defects and small/medium-sized respectively. After rescue surgery, the rate of closure achieved was 100%. The follow-up was 15.6 ± 12.4 months for large defects and 75.3 ± 51.3 months for small/medium-sized defects without recurrence. Endoscopic surgery for closure of any type of skull base defect is the gold standard approach. Defect size does not play a significant role in the success rate. Fascia lata and mucoperiosteum allow a reconstruction of small/medium-sized defects. For larger skull base defects, a combination of fat, fascia lata and nasoseptal pedicled flaps provide a successful reconstruction. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Wafer-level hermetic vacuum packaging by bonding with a copper-tin thin film sealing ring
NASA Astrophysics Data System (ADS)
Akashi, Teruhisa; Funabashi, Hirofumi; Takagi, Hideki; Omura, Yoshiteru; Hata, Yoshiyuki
2018-04-01
A wafer-level hermetic vacuum packaging technology intended for use with MEMS devices was developed based on a copper-tin (CuSn) thin film sealing ring. To allow hermetic packaging, the shear strength of the CuSn thin film bond was improved by optimizing the pretreatment conditions. As a result, an average shear strength of 72.3 MPa was obtained and a cavity that had been hermetically sealed using wafer-level packaging (WLP) maintained its vacuum for 1.84 years. The total pressures in the cavities and the partial pressures of residual gases were directly determined with an ultra-low outgassing residual gas analyzer (RGA) system. Hermeticity was evaluated based on helium leak rates, which were calculated from helium pressures determined with the RGA system. The resulting data showed that a vacuum cavity following 1.84 years storage had a total pressure of 83.1 Pa, contained argon as the main residual gas and exhibited a helium leak rate as low as 1.67 × 10-17 Pa · m3 s-1, corresponding to an air leak rate of 6.19 × 10-18 Pa · m3 s-1. The RGA data demonstrate that WLP using a CuSn thin film sealing ring permits ultra-high hermeticity in conjunction with long-term vacuum packaging that is applicable to MEMS devices.
Time to CUSUM: simplified reporting of outcomes in colorectal surgery.
Bowles, Thomas A; Watters, David A
2007-07-01
Surgical audit has added value when outcomes can be compared and individual surgeons receive feedback. It is expected that surgeons compare their results with others in similar local practice, the published work, or peers from a craft group audit. Although feedback and comparison are worthy aims, for many surgeons the standards have not been agreed nor is there a craft group audit. The aim of this paper was to develop a reporting format for surgeons carrying out colorectal surgery in a regional hospital. The performance of 13 individual surgeons was analysed using a comprehensive colorectal audit with more than 600 cases. Feedback included caseload and type. Risk stratification of outcomes included; operation urgency, age and Physiological and Operative Severity Score for enUmeration of Mortality and Morbidity. Outcome measures were anastomotic leaks, end stoma rates, unplanned reoperations and mortality. Visual feedback included cumulative summation graphs for elective leaks, mortality and unplanned reoperations. A single A4 page of an individuals performance could be prepared that allowed comparison to the groups data overall. Alerts were set at 2-5% elective leaks, 4-7.5% mortality and 4-11% unplanned return to theatre. Cumulative summation graphs added to this allowed a visual guide to the key performance indicators. Surgeons need to determine how they will review their individual and collective results. These are equally important to the reported work. Detailed analysis of risk-stratified data should occur. Binary outcomes such as leak, mortality and unplanned reoperations may be followed by cumulative summation graphs. This provides a continually updated method of feedback, enabling immediate visual feedback of a surgeon's performance.
Modeling the Progression of Epithelial Leak Caused by Overdistension
Hamlington, Katharine L.; Ma, Baoshun; Smith, Bradford J.; Bates, Jason H. T.
2016-01-01
Mechanical ventilation is necessary for treatment of the acute respiratory distress syndrome but leads to overdistension of the open regions of the lung and produces further damage. Although we know that the excessive stresses and strains disrupt the alveolar epithelium, we know little about the relationship between epithelial strain and epithelial leak. We have developed a computational model of an epithelial monolayer to simulate leak progression due to overdistension and to explain previous experimental findings in mice with ventilator-induced lung injury. We found a nonlinear threshold-type relationship between leak area and increasing stretch force. After the force required to initiate the leak was reached, the leak area increased at a constant rate with further increases in force. Furthermore, this rate was slower than the rate of increase in force, especially at end-expiration. Parameter manipulation changed only the leak-initiating force; leak area growth followed the same trend once this force was surpassed. These results suggest that there is a particular force (analogous to ventilation tidal volume) that must not be exceeded to avoid damage and that changing cell physical properties adjusts this threshold. This is relevant for the development of new ventilator strategies that avoid inducing further injury to the lung. PMID:26951764
Paravalvular Leak in Structural Heart Disease.
Goel, Kashish; Eleid, Mackram F
2018-03-06
This review will summarize the growing importance of diagnosing and managing paravalvular leak associated with surgical and transcatheter valves. The burden of paravalvular leak is increasing; however, advanced imaging techniques and high degree of clinical suspicion are required for diagnosis and management. The latest data from pivotal clinical trials in the field of transcatheter aortic valve replacement suggest that any paravalvular leak greater than mild was associated with worse clinical outcomes. Percutaneous techniques for paravalvular leak closure are now the preferred approach, and surgical repair is reserved for contraindications and unsuccessful procedures. Recent data from studies evaluating paravalvular leak closure outcomes report a greater than 90% success rate with a significant improvement in patient symptoms. Paravalvular leak is a growing problem in the structural heart disease arena. Percutaneous closure is successful in more than 90% of the procedures with a low complication rate.
A solenoid failure detection system for cold gas attitude control jet valves
NASA Technical Reports Server (NTRS)
Johnston, P. A.
1970-01-01
The development of a solenoid valve failure detection system is described. The technique requires the addition of a radioactive gas to the propellant of a cold gas jet attitude control system. Solenoid failure is detected with an avalanche radiation detector located in the jet nozzle which senses the radiation emitted by the leaking radioactive gas. Measurements of carbon monoxide leakage rates through a Mariner type solenoid valve are presented as a function of gas activity and detector configuration. A cylindrical avalanche detector with a factor of 40 improvement in leak sensitivity is proposed for flight systems because it allows the quantity of radioactive gas that must be added to the propellant to be reduced to a practical level.
Optical leak detection of oxygen using IR-laser diodes
NASA Technical Reports Server (NTRS)
Disimile, P. J.; Fox, C.; Toy, N.
1991-01-01
The ability to accurately measure the concentration of gaseous oxygen and its corresponding flow rate is becoming of greater importance. The technique being presented is based on the principal of light attenuation due to the absorption of radiation by the A-band of oxygen which is located in the 759-770 nm wavelength range. With an ability to measure the change in the light transmission to 0.05 percent, a sensitive optical leak detection system which has a rapid time response is possible. In this research program, the application of laser diode technology and its ability to be temperature tuned to a selected oxygen absorption spectral peak has allowed oxygen concentrations as low as 16,000 ppm to be detected.
Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.
Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J
2016-03-01
Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.
Methane Leak Rates from Natural Gas Wells in Norther California
NASA Astrophysics Data System (ADS)
Cui, Y.; Yoon, S.; Chen, Y.; Falk, M.; Kuwayama, T.; Croes, B. E.; Herner, J.; Vijayan, A.
2017-12-01
Methane is a potent greenhouse gas (GHG) and is the second most prevalent GHG emitted in California from human activities. As part of a comprehensive effort to reduce GHG emissions and meet the statewide climate goals, California has proposed a Short Lived Climate Pollutant (SLCP) Strategy that includes a 40% reduction of methane emissions from 2013 levels by 2030, with goals to reduce oil and gas related emissions and capture methane emissions from dairy operations and organic waste. There is growing evidence in the recent scientific literature suggesting that methane emissions can come from every stage of the oil and gas supply chain. During oil and gas production operations, studies reported that a small number of oil and gas wells made up a large fraction of total methane emissions from the wells. In such a fat-tail distribution, the mean methane leak rate from wells is orders of magnitude larger than the median, which indicates the presence of super emitter sources. However, since the super emitters are often positioned as outliers in a fat-tail distribution and do not always behave consistently, measuring their leak rates is challenging, but critical to quantify their impacts and identify potential mitigation opportunities. This presentation will discuss of methane leak rates measured from natural gas wells in Northern California for different well operations: active, idle, and plugged. The leak rates demonstrated fat-tail distributions, and the mean leak rates for each well operation status were an order of magnitude higher than the median leak rates. It was also observed that roughly 20% of wells contributed more than 80% of methane emissions. Further data collection is needed with a larger number of samples to better understand the relationship between the leak rates and well operation status. Such measurements could help improve the estimate of methane emissions from natural gas wells and inform methane reduction policies and programs in California.
Sleeve gastrectomy and the risk of leak: a systematic analysis of 4,888 patients.
Aurora, Alexander R; Khaitan, Leena; Saber, Alan A
2012-06-01
Sleeve gastrectomy has become a popular stand-alone bariatric procedure with comparable weight loss and resolution of comorbidities to that of laparoscopic gastric bypass. The simplicity of the procedure and the decreased long-term risk profile make this surgery more appealing. Nonetheless, the ever present risk of a staple-line leak is still of great concern and needs further investigation. An electronic literature search of MEDLINE database plus manual reference checks of articles published on laparoscopic sleeve gastrectomy for morbid obesity and its complications was completed. Keywords used in the search were "sleeve gastrectomy" OR "gastric sleeve" AND "leak." We analyzed 29 publications, including 4,888 patients. We analyzed the frequency of leak after sleeve gastrectomy and its associated risks of causation. The risk of leak after sleeve gastrectomy in all comers was 2.4%. This risk was 2.9% in the super-obese [body mass index (BMI) > 50 kg/m(2)] and 2.2% for BMI < 50 kg/m(2). Staple height and use of buttressing material did not affect leak rate. The use of a size 40-Fr or greater bougie was associated with a leak rate of 0.6% compared with those who used smaller sizes whose leak rate was 2.8%. Leaks were found at the proximal third of the stomach in 89% of cases. Most leaks were diagnosed after discharge. Endoscopic management is a viable option for leaks and was documented in 11% of cases as successful. Sleeve gastrectomy has become an important surgical option for the treatment of the ever growing morbidly obese population. The risk of leak is low at 2.4%. Attention to detail specifically at the esophagogastric junction cannot be stressed enough. Careful patient selection (BMI < 50 kg/m(2)) and adopting the use of a 40-Fr or larger bougie may decrease the risk of leak. Vigilant follow-up during the first 30 days is critical to avoid catastrophe, because most leaks will happen after patient discharge.
A Hydrogen Leak Detection System for Aerospace and Commercial Applications
NASA Technical Reports Server (NTRS)
Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.
1995-01-01
Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.
Distributed wireless sensing for methane leak detection technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Levente; van Kesse, Theodor
Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It ismore » demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.« less
Distributed wireless sensing for fugitive methane leak detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Levente J.; van Kessel, Theodore; Nair, Dhruv
Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It ismore » demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.« less
Distributed wireless sensing for fugitive methane leak detection
Klein, Levente J.; van Kessel, Theodore; Nair, Dhruv; ...
2017-12-11
Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It ismore » demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.« less
Sukkarieh, T; Harmon, J; Penna, F; Parra, R
2007-01-01
In laparoscopic prostatectomies, vesicourethral anastomotic leaks may result in significant morbidity because of the chemical and metabolic derangements created by urine within the peritoneal cavity. To date, minimal data are available on this problem. Herein we present our experience with urine leaks after RALP. Over a period of 24 months, 135 men underwent RALP. Any drainage creatinine greater than two times the serum creatinine was considered as an anastomotic leak. According to our criteria, 20% of the first 110 patients developed an anastomotic leak. The patients were analyzed in two groups, those with and without leaks. In the two groups, there was no statistically significant difference in age, height, weight, prostate volume and pre-op hemoglobin. The patients with leaks did have higher rate of prior abdominal surgery (50 vs. 36%), higher average pre-operative PSA values (7.6 vs. 6.1), higher rates of multiple biopsies (27 vs. 17%) and a higher average BMI (29.6 vs. 27.8). Intraoperative differences included an average of 30 min longer operative time and 66 cm(3) higher average EBL in patients with leaks. The transfusion rate was higher in the leak group at 18 vs. 1% in the no leak group. Recovery tended to be longer in patients with leaks, with hospital stays of an average of 3.6 days longer. The most common indication for prolonged hospitalization was ileus, which 55% of patients with leaks developed. Management included placing the catheter on mild traction, continuous antibiotics and taking the drain-off suction with caution to monitor the signs of a worsening ileus. In the last 25 patients, we revised our anastomotic technique. We now include posterior tailoring of the bladder neck prior to the vesicourethral anastomosis when the bladder neck is enlarged. This facilitates a water-tight anastomosis. Using this technique, we have yet to see the anastomotic leak. In RALPs, anastomotic leaks can lead to ileus formation and longer hospital stays. These leaks are associated with a higher average blood loss and transfusion rate. Management should focus on prevention. Since we have incorporated posterior bladder neck tailoring with the anastomosis, the problem has been markedly reduced.
Conger, Andrew; Zhao, Fan; Wang, Xiaowen; Eisenberg, Amalia; Griffiths, Chester; Esposito, Felice; Carrau, Ricardo L; Barkhoudarian, Garni; Kelly, Daniel F
2018-05-11
OBJECTIVE The authors previously described a graded approach to skull base repair following endonasal microscopic or endoscope-assisted tumor surgery. In this paper they review their experience with skull base reconstruction in the endoscopic era. METHODS A retrospective review of a single-institution endonasal endoscopic patient database (April 2010-April 2017) was undertaken. Intraoperative CSF leaks were graded based on size (grade 0 [no leak], 1, 2, or 3), and repair technique was documented across grades. The series was divided into 2 epochs based on implementation of a strict perioperative antibiotic protocol and more liberal use of permanent and/or temporary buttresses; repair failure rates and postoperative meningitis rates were assessed for the 2 epochs and compared. RESULTS In total, 551 operations were performed in 509 patients for parasellar pathology, including pituitary adenoma (66%), Rathke's cleft cyst (7%), meningioma (6%), craniopharyngioma (4%), and other (17%). Extended approaches were used in 41% of cases. There were 9 postoperative CSF leaks (1.6%) and 6 cases of meningitis (1.1%). Postoperative leak rates for all 551 operations by grade 0, 1, 2, and 3 were 0%, 1.9%, 3.1%, and 4.8%, respectively. Fat grafts were used in 33%, 84%, 97%, and 100% of grade 0, 1, 2, and 3 leaks, respectively. Pedicled mucosal flaps (78 total) were used in 2.6% of grade 0-2 leaks (combined) and 79.5% of grade 3 leaks (60 nasoseptal and 6 middle turbinate flaps). Nasoseptal flap usage was highest for craniopharyngioma operations (80%) and lowest for pituitary adenoma operations (2%). Two (3%) nasoseptal flaps failed. Contributing factors for the 9 repair failures were BMI ≥ 30 (7/9), lack of buttress (4/9), grade 3 leak (4/9), and postoperative vomiting (4/9). Comparison of the epochs showed that grade 1-3 repair failures decreased from 6/143 (4.1%) to 3/141 (2.1%) and grade 1-3 meningitis rates decreased from 5 (3.5%) to 1 (0.7%) (p = 0.08). Prophylactic lumbar CSF drainage was used in only 4 cases (< 1%), was associated with a higher meningitis rate in grades 1-3 (25% vs 2%), and was discontinued in 2012. Comparison of the 2 epochs showed increase buttress use in the second, with use of a permanent buttress in grade 1 and 3 leaks increasing from 13% to 55% and 32% to 76%, respectively (p < 0.001), and use of autologous septal/keel bone as a permanent buttress in grade 1, 2, and 3 leaks increasing from 15% to 51% (p < 0.001). CONCLUSIONS A graded approach to skull base repair after endonasal surgery remains valid in the endoscopic era. However, the technique has evolved significantly, with further reduction of postoperative CSF leak rates. These data suggest that buttresses are beneficial for repair of most grade 1 and 2 leaks and all grade 3 leaks. Similarly, pedicled flaps appear advantageous for grade 3 leaks, while CSF diversion may be unnecessary and a risk factor for meningitis. High BMI should prompt an aggressive multilayered repair strategy. Achieving repair failure and meningitis rates lower than 1% is a reasonable goal in endoscopic skull base tumor surgery.
Development of a leak location system for use on underground electric power transmission cable
NASA Astrophysics Data System (ADS)
Williams, J. A.
1982-10-01
This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000 m long on a feeder that might be 30 km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection and detection scheme was developed for use in areas where the dogs may be unsuitable.
NASA Astrophysics Data System (ADS)
Leen, J. B.; Spillane, S.; Gardner, A.; Hansen, P. C.; Gupta, M.; Baer, D. S.
2015-12-01
Natural gas leaks pose a risk to public safety both because of potential explosions as well as from the greenhouse gas potential of fugitive methane. The rapid and cost effective detection of leaks in natural gas distribution is critical to providing a system that is safe for the public and the environment. Detection of methane from a mobile platform (vehicles, aircraft, etc.) is an accepted method of identifying leaks. A robust approach to differentiating pipeline gas (thermogenic) from other biogenic sources is the detection of ethane along with methane. Ethane is present in nearly all thermogenic gas but not in biogenic sources and its presence can be used to positively identify a gas sample. We present a mobile system for the simultaneous measurement of methane and ethane that is capable of detecting pipeline leaks and differentiating pipeline gas from other biogenic sources such as landfills, swamps, sewers, and enteric fermentation. The mobile system consists of a high precision GPS, sonic anemometer, and methane/ethane analyzer based on off-axis integrated cavity output spectroscopy (OA-ICOS). In order to minimize the system cost and facilitate the wide use of mobile leak detection, the analyzer operates in the near-infrared portion of the spectrum where lasers and optics are significantly less costly than in the mid-infrared. The analyzer is capable of detecting methane with a precision of <2 ppb (1σ in 1 sec) and detecting ethane with a precision of <30 ppb (1σ in 1 sec). Additionally, measurement rates of 5 Hz allow for detection of leaks at speeds up to 50 mph. The sonic anemometer, GPS and analyzer inlet are mounted to a generic roof rack for attachment to available fleet vehicles. The system can detect leaks having a downwind concentration of as little as 10 ppb of methane above ambient, while leaks 500 ppb above ambient can be identified as thermogenic with greater than 99% certainty (for gas with 6% ethane). Finally, analysis of wind data provides an estimate of leak direction and distance. The system presented provides a robust, cost effective solution to natural gas leak detection and attribution to maximize safety and minimize greenhouse gas impacts of distribution systems.
Initiation and propagation of a PKN hydraulic fracture in permeable rock: Toughness dominated regime
NASA Astrophysics Data System (ADS)
Sarvaramini, E.; Garagash, D.
2011-12-01
The present work investigates the injection of a low-viscosity fluid into a pre-existing fracture with constrained height (PKN), as in waterflooding or supercritical CO2 injection. Contrary to conventional hydraulic fracturing, where 'cake build up' limits diffusion to a small zone, the low viscosity fluid allows for diffusion over a wider range of scales. Over large injection times the pattern becomes 2 or 3-D, necessitating a full-space diffusion modeling. In addition, the dissipation of energy associated with fracturing of rock dominates the energy needed for the low-viscosity fluid flow into the propagating crack. As a result, the fracture toughness is important in evaluating both the initiation and the ensuing propagation of these fractures. Classical PKN hydraulic fracturing model, amended to account for full-space leak-off and the toughness [Garagash, unpublished 2009], is used to evaluate the pressure history and fluid leak-off volume during the injection of low viscosity fluid into a pre-existing and initially stationary. In order to find the pressure history, the stationary crack is first subject to a step pressure increase. The response of the porous medium to the step pressure increase in terms of fluid leak-off volume provides the fundamental solution, which then can be used to find the transient pressurization using Duhamel theorem [Detournay & Cheng, IJSS 1991]. For the step pressure increase an integral equation technique is used to find the leak-off rate history. For small time the solution must converge to short time asymptote, which corresponds to 1-D diffusion pattern. However, as the diffusion length in the zone around the fracture increases the assumption of a 1-D pattern is no longer valid and the diffusion follows a 2-D pattern. The solution to the corresponding integral equation gives the leak-off rate history, which is used to find the cumulative leak-off volume. The transient pressurization solution is obtained using global conservation of fluid injected into the fracture. With increasing pressure in the fracture due to the fluid injection, the energy release rate eventually becomes equal to the toughness and fracture propagates. The evolution of the fracture length is established using the method similar to the one employed for the stationary crack.
40 CFR 63.1086 - How must I monitor for leaks to cooling water?
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitor for leaks to cooling water? You must monitor for leaks to cooling water by monitoring each heat... system so that the cooling water flow rate is 51,031 liters per minute or less so that a leak of 3.06 kg... detected a leak. (b) Individual heat exchangers. Monitor the cooling water at the entrance and exit of each...
Postoperative ascitic leaks: the ongoing challenge.
Rosemurgy, A S; Statman, R C; Murphy, C G; Albrink, M H; McAllister, E W
1992-06-01
The leak of ascitic fluid from surgical incisions is thought to be associated with a very high mortality rate. There have been few reports, however, focusing on the clinical characteristics, management, or mortality rates of this condition. During a 10-year period, 18 patients with postoperative ascitic fluid leaks were treated. All patients had ascites before surgery and all had liver disease; in 13 of the 18 patients alcoholic liver disease was the cause of ascites. Ten of the 18 patients died (56%). Midline incisions were more often associated with recalcitrant leaks and fatal complications than were transverse incisions. Early consideration of fascial dehiscence and prompt repair is emphasized. The most effective predictor of survival was cessation of the leak.
Test program, helium II orbital resupply coupling
NASA Technical Reports Server (NTRS)
Hyatt, William S.
1991-01-01
The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.
N-16 monitors: Almaraz NPP experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adrada, J.
1997-02-01
Almaraz Nuclear Power Plant has installed N-16 monitors - one per steam generator - to control the leakage rate through the steam generator tubes after the application of leak before break (LBB) criteria for the top tube sheet (TTS). After several years of operation with the N-16 monitors, Almaraz NPP experience may be summarized as follows: N-16 monitors are very useful to follow the steam generator leak rate trend and to detect an incipient tube rupture; but they do not provide an exact absolute leak rate value, mainly when there are small leaks. The evolution of the measured N-16 leakmore » rates varies along the fuel cycle, with the same trend for the 3 steam generators. This behaviour is associated with the primary water chemistry evolution along the cycle.« less
Fibrin glue as agent for sealing corneal and conjunctival wound leaks.
Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S
2018-02-01
PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.
Han, Zong-Li; He, Dong-Sheng; Mao, Zhi-Gang; Wang, Hai-Jun
2008-06-01
To determine the incidence, risk factors, diagnostic procedures, and management of cerebrospinal fluid (CSF) leaks following trans-sphenoidal pituitary macroadenoma surgery. Retrospective analysis of 592 patients. Intra- and post-operative CSF leaks occurred in 14.2 and 4.4% of patients, respectively. Surgical revision, tumor consistency, and tumor margins were independently associated with intra-operative leaks, while the tumor size, consistency, and margins were risk factors of post-operative leaks. The intra-operative leak rate of ACTH adenomas was greater than all other types combined; the incidence of post-operative CSF leaks was highest for FSH adenomas. There were no significant differences among various techniques and we achieved an initial repair success rates of 83.3 and 92.9% for intra- and post-operative CSF leaks, respectively. Of the 26 patients with post-operative CSF leaks, five were complicated by meningitis and four by post-infectious hydrocephalus which required ventriculoperitoneal shunts. CSF leaks have a propensity to occur in cases with fibrous tumors or tumors with indistinct margin and may have some relationship with the tumor type. Endoscopic and microscopic repairs were shown to be effective techniques in managing these types of leaks. Post-infectious hydrocephalus may influence the outcome of the repair and ventriculoperitoneal shunts were necessary in some cases.
Evaluation of a Conductive Elastomer Seal for Spacecraft
NASA Technical Reports Server (NTRS)
Daniels, C. C.; Mather, J. L.; Oravec, H. A.; Dunlap, P. H., Jr.
2016-01-01
An electrically conductive elastomer was evaluated as a material candidate for a spacecraft seal. The elastomer used electrically conductive constituents as a means to reduce the resistance between mating interfaces of a sealed joint to meet spacecraft electrical bonding requirements. The compound's outgassing levels were compared against published NASA requirements. The compound was formed into a hollow O-ring seal and its compression set was measured. The O-ring seal was placed into an interface and the electrical resistance and leak rate were quantified. The amount of force required to fully compress the test article in the sealing interface and the force needed to separate the joint were also measured. The outgassing and resistance measurements were below the maximum allowable levels. The room temperature compression set and leak rates were fairly high when compared against other typical spacecraft seal materials, but were not excessive. The compression and adhesion forces were desirably low. Overall, the performance of the elastomer compound was sufficient to be considered for future spacecraft seal applications.
Noble Gas Leak Detector for Use in the SNS Neutron Electric Dipole Moment Experiment
NASA Astrophysics Data System (ADS)
Barrow, Chad; Huffman, Paul; Leung, Kent; Korobkina, Ekaterina; White, Christian; nEDM Collaboration Collaboration
2017-09-01
Common practice for leak-checking high vacuum systems uses helium as the probing gas. However, helium may permeate some materials at room temperature, making leak characterization difficult. The experiment to find a permanent electric dipole moment of the neutron (nEDM), to be conducted at Oak Ridge National Laboratories, will employ a large volume of liquid helium housed by such a helium-permeable composite material. It is desirable to construct a leak detector that can employ alternative test gases. The purpose of this experiment is to create a leak detector that can quantify the argon gas flux in a high vacuum environment and interpret this flux as a leak-rate. This apparatus will be used to check the nEDM volumes for leaks at room temperature before cooling down to cryogenic temperatures. Our leak detector uses a residual gas analyzer and a vacuum pumping station to characterize the gas present in an evacuated volume. The introduction of argon gas into the system is interpreted as a leak-rate into the volume. The device has been calibrated with NIST certified calibrated leaks and the machine's sensitivity has been calculated using background gas analysis. As a result of the device construction and software programming, we are able to leak-check composite and polyamide volumes This work was supported in part by the US Department of Energy under Grant No. DE-FG02-97ER41042.
40 CFR 264.253 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... rate into the leak detection system exceeds the action leakage rate for any sump, the owner or operator... thereafter, as long as the flow rate in the leak detection system exceeds the action leakage rate, the owner... must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the...
Ullrich, Tim Leon; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik Stefan
2018-06-01
Heated humidification is paramount during neonatal high-flow nasal cannula (HFNC) therapy. However, there is little knowledge about the influence of flow rate and mouth leak on oropharyngeal humidification and temperature. The effect of the Optiflow HFNC on oropharyngeal gas conditioning was investigated at flow rates of 4, 6 and 8 L min -1 with and without mouth leak in a bench model simulating physiological oropharyngeal air conditions during spontaneous breathing. Temperature and absolute humidity (AH) were measured using a digital thermo-hygrosensor. Without mouth leak, oropharyngeal temperature and AH increased significantly with increasing flow (P < 0.001). Mouth leak did not affect this increase up to 6 L min -1 , but at 8 L min -1 , temperature and AH plateaued, and the effect of mouth leak became statistically significant (P < 0.001). Mouth leak during HFNC had a negative impact on oropharyngeal gas conditioning when high flows were applied. However, temperature and AH always remained clinically acceptable.
NASA Astrophysics Data System (ADS)
Bhattachryya, Pranab; Gupta, Anjan Dutta; Dhar, S.; Sarma, P. R.; Mukherjee, Paramita
2017-06-01
The helium vessel of the superconducting cyclotron (SCC) at the Variable Energy Cyclotron centre (VECC), Kolkata shows a gradual loss of insulation vacuum from 10-7 mbar to 10-4 mbar with increasing coil current in the magnet. The insulation vacuum restores back to its initial value with the withdrawal of current. The origin of such behavior has been thought to be related to the electromagnetic stress in the magnet. The electromagnetic stress distribution in the median plane of the helium vessel was studied to figure out the possible location of the helium leak. The stress field from the possible location was transferred to a simplified 2D model with different leak geometries to study the changes in conductance with coil current. The leak rate calculated from the changes in the leak geometry was compared with the leak rate calculated from the experimental insulation vacuum degradation behavior to estimate the initial leak shape and size.
The mechanical and microbiological integrity of surgical gloves.
Jamal, Ala; Wilkinson, Stephen
2003-03-01
Several manufacturers supply surgical gloves that have been individually tested (IT) for leaks. Other manufacturers supply gloves in which sample gloves from each batch are tested for leaks (batch tested: BT). The latter brands may be rejected by surgeons because of presumed increased risk of wound infection and staff exposure to patient pathogens. The influence of differences between glove brands on performance in surgery has not been extensively studied. The aims of the present study were to test the mechanical and microbiological integrity of IT compared to BT gloves. A total of 110 unused gloves from each of an IT and a BT brand were tested for leaks, first, by observation of water-jets from water-filled gloves and second, by measuring electrical resistance between inside and outside the glove surfaces, to give a baseline measure. A total of 304 IT and 280 BT gloves were then similarly leak-tested after 98 clean surgical procedures. The hands and gloves of scrub team members were cultured postsurgery. A total of 1/110 BT and 0/110 IT unused gloves contained leaks (NS, Fisher's exact test). Operative perforation rates were lower for BT compared with IT (8/280 cf. 22/304; P < 0.05 Fisher's exact test). There was no bias in types of operations or scrub team members to account for the difference. Growth of normal skin flora was found on virtually every wearer's hands post-operatively. Similar bacteria were frequently cultured from the outside of gloves at the conclusion of surgery (111/152 pairs IT cf. 122/140 pairs BT; P < 0.01, Fisher's exact test). This study provides evidence that the clinical performance of BT gloves is no different to IT gloves. There was no significant difference in mechanical leak rates for unused gloves. Paradoxically, although IT gloves were more likely to show macro-perforations after surgery, the incidence of contamination on the surface of BT gloves was greater, possibly reflecting a qualitative difference in glove material. This study suggests that both types of gloves develop microporosity during use, which may allow transfer of bacteria from the surgeon's skin to the surface of the glove.
Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine
NASA Technical Reports Server (NTRS)
Schwabacher, Mark A.; Aguilar, Robert; Figueroa, Fernando F.
2009-01-01
The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.
Identification of sewage leaks by active remote-sensing methods
NASA Astrophysics Data System (ADS)
Goldshleger, Naftaly; Basson, Uri
2016-04-01
The increasing length of sewage pipelines, and concomitant risk of leaks due to urban and industrial growth and development is exposing the surrounding land to contamination risk and environmental harm. It is therefore important to locate such leaks in a timely manner, to minimize the damage. Advances in active remote sensing Ground Penetrating Radar (GPR) and Frequency Domain Electromagnetic (FDEM) technologies was used to identify leaking potentially responsible for pollution and to identify minor spills before they cause widespread damage. This study focused on the development of these electromagnetic methods to replace conventional acoustic methods for the identification of leaks along sewage pipes. Electromagnetic methods provide an additional advantage in that they allow mapping of the fluid-transport system in the subsurface. Leak-detection systems using GPR and FDEM are not limited to large amounts of water, but enable detecting leaks of tens of liters per hour, because they can locate increases in environmental moisture content of only a few percentage along the pipes. The importance and uniqueness of this research lies in the development of practical tools to provide a snapshot and monitoring of the spatial changes in soil moisture content up to depths of about 3-4 m, in open and paved areas, at relatively low cost, in real time or close to real time. Spatial measurements performed using GPR and FDEM systems allow monitoring many tens of thousands of measurement points per hectare, thus providing a picture of the spatial situation along pipelines and the surrounding. The main purpose of this study was to develop a method for detecting sewage leaks using the above-proposed geophysical methods, since their contaminants can severely affect public health. We focused on identifying, locating and characterizing such leaks in sewage pipes in residential and industrial areas.
Optimal sensor placement for leak location in water distribution networks using genetic algorithms.
Casillas, Myrna V; Puig, Vicenç; Garza-Castañón, Luis E; Rosich, Albert
2013-11-04
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach.
Optimal Sensor Placement for Leak Location in Water Distribution Networks Using Genetic Algorithms
Casillas, Myrna V.; Puig, Vicenç; Garza-Castañón, Luis E.; Rosich, Albert
2013-01-01
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach. PMID:24193099
Johnston, W Forrest; Stafford, Caitlin; Francone, Todd D; Read, Thomas E; Marcello, Peter W; Roberts, Patricia L; Ricciardi, Rocco
2017-12-01
Approximately half of Crohn's patients require intestinal resection, and many need repeat resections. The purpose of this study was to evaluate the increased risk of clinical anastomotic leak in patients with a history of previous intestinal resection undergoing repeat resection with anastomosis for Crohn's disease. This was a retrospective analysis of prospectively collected departmental data with 100% capture. The study was conducted at the department of colorectal surgery in a tertiary care teaching hospital between July 2007 and March 2016. A cohort of consecutive patients with Crohn's disease who were treated with intestinal resection and anastomosis, excluding patients with proximal fecal diversion, were included. The cohort was divided into 2 groups, those with no previous resection compared with those with previous resection. Clinical anastomotic leak within 30 days of surgery was measured. Of the 206 patients who met criteria, 83 patients had previous intestinal resection (40%). The 2 groups were similar in terms of patient factors, immune-suppressing medication use, and procedural factors. Overall, 20 clinical anastomotic leaks were identified (10% leak rate). There were 6 leaks (5%) detected in patients with no previous intestinal resection and 14 leaks (17%) detected in patients with a history of previous intestinal resection (p < 0.005). The OR of anastomotic leak in patients with Crohn's disease with previous resection compared with no previous resection was 3.5 (95% CI, 1.3-9.4). Patients with 1 previous resection (n = 53) had a leak rate of 13%, whereas patients with ≥2 previous resections (n = 30) had a leak rate of 23%. The number of previous resections correlated with increasing risk for clinical anastomotic leak (correlation coefficient = 0.998). This was a retrospective study with limited data to perform a multivariate analysis. Repeat intestinal resection in patients with Crohn's disease is associated with an increased rate of anastomotic leakage when compared with initial resection despite similar patient, medication, and procedural factors. See Video Abstract at http://links.lww.com/DCR/A459.
Routine intraoperative leak testing for sleeve gastrectomy: is the leak test full of hot air?
Bingham, Jason; Lallemand, Michael; Barron, Morgan; Kuckelman, John; Carter, Preston; Blair, Kelly; Martin, Matthew
2016-05-01
Staple line leak after sleeve gastrectomy (SG) is a rare but dreaded complication with a reported incidence of 0% to 8%. Many surgeons routinely test the staple line with an intraoperative leak test (IOLT), but there is little evidence to validate this practice. In fact, there is a theoretical concern that the leak test may weaken the staple line and increase the risk of a postop leak. Retrospective review of all SGs performed over a 7-year period was conducted. Cases were grouped by whether an IOLT was performed, and compared for the incidence of postop staple line leaks. The ability of the IOLT for identifying a staple line defect and for predicting a postoperative leak was analyzed. Five hundred forty-two SGs were performed between 2007 and 2014. Thirteen patients (2.4%) developed a postop staple line leak. The majority of patients (n = 494, 91%) received an IOLT, including all 13 patients (100%) who developed a subsequent clinical leak. There were no (0%) positive IOLTs and no additional interventions were performed based on the IOLT. The IOLT sensitivity and positive predictive value were both 0%. There was a trend, although not significant, to increase leak rates when a routine IOLT was performed vs no routine IOLT (2.6% vs 0%, P = .6). The performance of routine IOLT after SG provided no actionable information, and was negative in all patients who developed a postoperative leak. The routine use of an IOLT did not reduce the incidence of postop leak, and in fact was associated with a higher leak rate after SG. Published by Elsevier Inc.
Achieving low anastomotic leak rates utilizing clinical perfusion assessment.
Kream, Jacob; Ludwig, Kirk A; Ridolfi, Timothy J; Peterson, Carrie Y
2016-10-01
Anastomotic leak after colorectal resection increases morbidity, mortality, and in the setting of cancer, increases recurrences rates and reduces survival odds. Recent reports suggest that fluorescence evaluation of perfusion after colorectal anastomosis creation is associated with low anastomotic leak rates (1.4%). The purpose of this work was to evaluate whether a similar low anastomotic leak rate after left-sided colorectal resections could be achieved using standard assessment of blood flow to the bowel ends. We performed a retrospective chart review at an academic tertiary referral center, evaluating 317 consecutive patients who underwent a pelvic anastomosis after sigmoid colectomy, left colectomy, or low anterior resection. All operations were performed by a single surgeon from March 2008 to January 2015 with only standard clinical measures used to assess perfusion to the bowel ends. The primary outcome measure was the anastomotic leak rate as diagnosed by clinical symptoms, exam, or routine imaging. The average patient age was 59.7 years with an average body mass index of 28.8 kg/m(2). Rectal cancer (128, 40.4%) was the most common indication for operation while hypertension (134, 42.3%) was the most common comorbidity. In total, 177 operations were laparoscopic (55.8%), 13 were reoperative resections (4.1%), and 108 were protected with a loop ileostomy (34.1%). Preoperative chemotherapy was administered to 25 patients (7.9%) while preoperative chemo/radiation was administered to 64 patients (20.2%). The anastomotic leak rate was 1.6% (5/317). Our data suggests that standard, careful evaluation of adequate blood flow via inspection and confirmation of pulsatile blood flow to the bowel ends and meticulous construction of the colorectal or coloanal anastomoses can result in very low leak rates, similar to the rate reported when intraoperative imaging is used to assess perfusion. Copyright © 2016 Elsevier Inc. All rights reserved.
Hermetic Seal Leak Detection Apparatus
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2013-01-01
The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.
Elastomeric Seal Performance after Terrestrial Ultraviolet Radiation Exposure
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.; Dunlap, Patrick H.
2015-01-01
Ultraviolet radiation was evaluated to determine its negative effects on the performance of elastomeric gas pressure seals. The leak rates of the silicone elastomer S0383-70 O-ring test articles were used to quantify the degradation of the seals after exposure to vacuum-ultraviolet and/or middle-to-near-ultraviolet wavelength radiation. Three groups of seals were exposed in terrestrial facilities to 115-165 nm wavelength radiation, 230-500 nm wavelength radiation, or both spectrums, for an orbital spaceflight equivalent of 125 hours. The leak rates of the silicone elastomer S0383-70 seals were quantified and compared to samples that received no radiation. Each lot contained six samples and statistical t-tests were used to determine the separate and combined influences of exposure to the two wavelength ranges. A comparison of the mean leak rates of samples exposed to 115-165 nm wavelength radiation to the control specimens showed no difference, suggesting that spectrum was not damaging. The 230-500 nm wavelength appeared to be damaging, as the mean leak rates of the specimens exposed to that range of wavelengths, and those exposed to the combined 115-165 nm and 230-500 nm spectrums, were significantly different from the leak rates of the control specimens. Most importantly, the test articles exposed to both wavelength spectrums exhibited mean leak rates two orders of magnitude larger than any other exposed specimens, which suggested that both wavelength spectrums are important when simulating the orbital environment.
Aerospace Payloads Leak Test Methodology
NASA Technical Reports Server (NTRS)
Lvovsky, Oleg; Grayson, Cynthia M.
2010-01-01
Pressurized and sealed aerospace payloads can leak on orbit. When dealing with toxic or hazardous materials, requirements for fluid and gas leakage rates have to be properly established, and most importantly, reliably verified using the best Nondestructive Test (NDT) method available. Such verification can be implemented through application of various leak test methods that will be the subject of this paper, with a purpose to show what approach to payload leakage rate requirement verification is taken by the National Aeronautics and Space Administration (NASA). The scope of this paper will be mostly a detailed description of 14 leak test methods recommended.
Preliminary study of the use of radiotracers for leak detection in industrial applications
NASA Astrophysics Data System (ADS)
Wetchagarun, S.; Petchrak, A.; Tippayakul, C.
2015-05-01
One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.
Leak test adapter for containers
Hallett, Brian H.; Hartley, Michael S.
1996-01-01
An adapter is provided for facilitating the charging of containers and leak testing penetration areas. The adapter comprises an adapter body and stem which are secured to the container's penetration areas. The container is then pressurized with a tracer gas. Manipulating the adapter stem installs a penetration plug allowing the adapter to be removed and the penetration to be leak tested with a mass spectrometer. Additionally, a method is provided for using the adapter.
Anastomotic leaks in stage IV colorectal cancer.
Ng, Suat Chin; Stupart, Douglas; Bartolo, David; Watters, David
2018-06-12
The purpose of this study was to determine the anastomotic leak rate for colorectal cancer resections in patients with metastases (compared to those without), and to determine the impact of anastomotic leaks on survival. This is a retrospective analysis of all patients who underwent resection and primary anastomosis for colorectal adenocarcinoma at a single institution between January 2002 and December 2014. A total of 843 patients underwent a resection and primary anastomosis for colorectal adenocarcinoma (661 colon and 182 rectal). Of these, 135 (16%) had metastases and 708 (84%) did not. Anastomotic leaks occurred in 17 of 135 (13%) patients with metastases, and in 37 of 798 (5.2%) patients without metastases (P = 0.003). Peri-operative mortality occurred in 13 of 135 (9.6%) patients with metastases, compared with 19 of 708 (2.7%) patients without metastases (P = 0.0003). Anastomotic leak was associated with a reduction in overall survival (median survival 121 months without anastomotic leak versus 66 months in patients who had an anastomotic leak (P = 0.02)). If the patients who died peri-operatively are excluded from this analysis, however, long-term mortality was similar (125 months versus 101 months; P = 0.70). Metastatic disease was associated with an increased risk of anastomotic leak and a higher peri-operative mortality rate after colorectal resections for cancer. Patients with anastomotic leaks had a higher peri-operative mortality rate, but long-term survival was unaffected beyond the peri-operative phase. © 2018 Royal Australasian College of Surgeons.
Of Detection Limits and Effective Mitigation: The Use of Infrared Cameras for Methane Leak Detection
NASA Astrophysics Data System (ADS)
Ravikumar, A. P.; Wang, J.; McGuire, M.; Bell, C.; Brandt, A. R.
2017-12-01
Mitigating methane emissions, a short-lived and potent greenhouse gas, is critical to limiting global temperature rise to two degree Celsius as outlined in the Paris Agreement. A major source of anthropogenic methane emissions in the United States is the oil and gas sector. To this effect, state and federal governments have recommended the use of optical gas imaging systems in periodic leak detection and repair (LDAR) surveys to detect for fugitive emissions or leaks. The most commonly used optical gas imaging systems (OGI) are infrared cameras. In this work, we systematically evaluate the limits of infrared (IR) camera based OGI system for use in methane leak detection programs. We analyze the effect of various parameters that influence the minimum detectable leak rates of infrared cameras. Blind leak detection tests were carried out at the Department of Energy's MONITOR natural gas test-facility in Fort Collins, CO. Leak sources included natural gas wellheads, separators, and tanks. With an EPA mandated 60 g/hr leak detection threshold for IR cameras, we test leak rates ranging from 4 g/hr to over 350 g/hr at imaging distances between 5 ft and 70 ft from the leak source. We perform these experiments over the course of a week, encompassing a wide range of wind and weather conditions. Using repeated measurements at a given leak rate and imaging distance, we generate detection probability curves as a function of leak-size for various imaging distances, and measurement conditions. In addition, we estimate the median detection threshold - leak-size at which the probability of detection is 50% - under various scenarios to reduce uncertainty in mitigation effectiveness. Preliminary analysis shows that the median detection threshold varies from 3 g/hr at an imaging distance of 5 ft to over 150 g/hr at 50 ft (ambient temperature: 80 F, winds < 4 m/s). Results from this study can be directly used to improve OGI based LDAR protocols and reduce uncertainty in estimated mitigation effectiveness. Furthermore, detection limits determined in this study can be used as standards to compare new detection technologies.
40 CFR 264.304 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... into the leak detection system exceeds the action leakage rate for any sump, the owner or operator must... thereafter, as long as the flow rate in the leak detection system exceeds the action leakage rate, the owner... forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response...
Study of Residual Gas Analyser (RGA) Response towards Known Leaks
NASA Astrophysics Data System (ADS)
Pathan, Firozkhan S.; Khan, Ziauddin; Semwal, Pratibha; George, Siju; Raval, Dilip C.; Thankey, Prashant L.; Manthena, Himabindu; Yuvakiran, Paravastu; Dhanani, Kalpesh R.
2012-11-01
Helium leak testing is the most versatile form of weld qualification test for any vacuum application. Almost every ultra-high vacuum (UHV) system utilizes this technique for insuring leak tightness for the weld joints as well as demountable joints. During UHV system under operational condition with many other integrated components, in-situ developed leaks identification becomes one of the prime aspect for maintaining the health of such system and for continuing the experiments onwards. Since online utilization of leak detector (LD) has many practical limitations, residual gas analyser (RGA) can be used as a potential instrument for online leak detection. For this purpose, a co-relation for a given leak rate between Leak Detector and RGA is experimentally established. This paper describes the experimental aspect and the relationship between leak detector and RGA.
Mehta, Gautam U; Oldfield, Edward H
2012-06-01
Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p < 0.001). This reduction occurred in macroadenomas with (from 57% to 5%, p < 0.001) and those without suprasellar extension (from 29% to 0%, p = 0.31). The rate of postoperative CSF leakage was similar (5% vs 5%), despite the fact that intraoperative CSF drainage reduced the need for operative repair (from 32% to 5%, p < 0.001). There were no significant catheter-related complications. Cerebrospinal fluid drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.
Closure of ascites leaks with fibrin glue injection in patients with end-stage liver disease.
Sadik, Karim W; Laibstain, Sarah; Northup, Patrick G; Kashmer, David; Schmitt, Timothy M; Bonatti, Hugo J R
2011-09-01
Ascites leaks (AL) in patients with end-stage liver disease (ESLD) are associated with significant morbidity and mortality regardless if they are medically or surgically managed. In a pilot study, 14 ESLD patients with AL underwent treatment with fibrin glue injection around the leak after failing conservative therapy. The end point of this study was the cessation of AL in the short term and the maintenance of a leak-free abdomen in the long term, allowing for medical optimization of the patients. Median age of the 10 men and 4 women was 50 (range 26-67) years. Underlying ESLDs were chronic hepatitis C (n=5), alcoholic LD (n=2), cryptogenic cirrhosis (n=2), and miscellaneous (n=5). There were six leaking incisions posthernia repair (three umbilical and three inguinal), two leaking/ruptured umbilical hernias, four leaking paracentesis sites, one leaking Jackson-Pratt (JP) drain canal, and one leaking laparoscopic trocar site. Average AL volume per day was 1000 (range 400-2000) mL. All leaks were immediately resolved with a 3-5 mL fibrin glue injection. Five recurred and required a second injection (four within 24 hours). Mental status improved in 7 patients (West Haven Criteria: grade II to I [n=6], grade III to I [n=1]). Median model of end-stage liver disease scores improved from 23 (range 8-33) to 20 (range 14-26). There were no infections, bleeds, or other injection-related complications. Average follow-up for these patients was 441.6 days (range 2-852). Five patients underwent liver transplant (LT) median 15 (range 4-270) days postinjection; 2 of them died. Another 3 patients died (2 from sepsis and 1 from metastatic cancer). Fibrin glue injection for the control of AL is a simple and safe bedside procedure that quickly controls AL, allowing for patient recovery in anticipation of further care.
Chouliaras, Konstantinos; Levine, Edward A; Fino, Nora; Shen, Perry; Votanopoulos, Konstantinos I
2017-04-01
Gastrointestinal leak (GIL) after cytoreductive surgery with heated intraperitoneal chemotherapy (CRS/HIPEC) is associated with significant morbidity and mortality. This study aimed to identify GIL prognostic factors and its impact on overall survival. A retrospective analysis of a prospectively maintained database comprising 1270 CRS/HIPEC procedures was performed. Type of GIL, functional and resection status, morbidity, mortality, and survival were reviewed. Gastrointestinal leaks were identified in 8.7% (110/1270) of CRS/HIPEC procedures, including 53 anastomotic leaks (4.2%), 53 hollow viscus perforations (4.2%), and four leaks at unknown sites. The multivariate predictors of leak were Eastern Cooperative Oncology Group (ECOG) functional status (ECOG 1 vs. 0: odds ratio [OR] 2.12, p = 0.009; ECOG 2 vs. 0: OR 2.90, p = 0.004), and number of anastomoses (OR 5.34; p < 0.0001). The in-hospital mortality rate for the GIL cohort was 21.8% (24/110), with a 72% (80/110) reoperation rate. The leak cohort had a higher major morbidity rate (88.3 vs. 23.3%; p < 0.0001), a longer hospital stay (39.0 vs. 9.9 days; p < 0.0001), and a longer intensive care unit (ICU) stay (7.7 vs. 1.7 days; p = 0.0003). After surgical mortality was excluded, the overall survival periods for the leak and no-leak patients with complete cytoreduction were respectively 1.5 and 4.98 years (p = 0.0001). Clinically significant decreases in survival were observed for all primary malignancies. Gastrointestinal leak after CRS/HIPEC is a source of significant mortality, with a decrease in overall survival even after complete CRS. Preoperative functional status and number of anastomoses are predictors of leak for CRS/HIPEC patients.
Juloori, Aditya; Tucker, Susan L; Komaki, Ritsuko; Liao, Zhongxing; Correa, Arlene M; Swisher, Stephen G; Hofstetter, Wayne L; Lin, Steven H
2014-04-01
Postoperative morbidities, such as anastomotic leaks, are common after trimodality therapy (chemoradiation followed by surgery) for esophageal cancer. We investigated for factors associated with an increased incidence of anastomotic leaks. Data from 285 esophageal cancer patients treated from 2000 to 2011 with trimodality therapy were analyzed. Anastomotic location relative to preoperative radiation field was assessed using postoperative computed tomographic imaging. Logistic regression was used to evaluate for factors associated with any or clinically relevant (CR) (≥ grade 2) leaks. Overall anastomotic leak rate was 11% (31 of 285), and CR leak rate was 6% (17 of 285). Multivariable analysis identified body mass index (odds ratio [OR], 1.09; 95% confidence interval [CI], 1.00-1.17; OR, 1.11, 95% CI, 1.01-1.22), three-field surgery (OR, 10.01; 95% CI, 3.83-26.21; OR, 4.83; 95% CI, 1.39-16.71), and within radiation field ("in-field") anastomosis (OR, 5.37; 95% CI, 2.21-13.04; OR, 8.63; 95% CI, 2.90-25.65) as independent predictors of both all grade and CR leaks, respectively. While patients with distal esophageal tumors and Ivor-Lewis surgery had the lowest incidence of all grade (6.5%) and CR leaks (4.2%), most of the leaks were associated with the anastomosis constructed within the field of radiation (in-field: 39% and 30% versus out-of-field: 2.6% and 1.0%, respectively, for total and CR leaks, p less than 0.0001, Fisher's exact test). Esophagogastric anastomosis placed within the preoperative radiation field was a very strong predictor for anastomotic leaks in esophageal cancer patients treated with trimodality therapy, among other factors. Surgical planning should include a critical evaluation of the preoperative radiation fields to ensure proper anastomotic placement after chemoradiation therapy.
Nordholm-Carstensen, Andreas; Rolff, Hans Christian; Krarup, Peter-Martin
2017-05-01
Anastomotic leak has a negative impact on the prognosis of patients who undergo colorectal cancer resection. However, data on anastomotic leak are limited for stage IV colorectal cancers. The purpose of this study was to investigate the impact of anastomotic leak on survival and the decision to administer chemotherapy and/or metastasectomy after elective surgery for stage IV colorectal cancer. This was a nationwide, retrospective cohort study. Data were obtained from the Danish Colorectal Cancer Group, the Danish Pathology Registry, and the National Patient Registry. Patients who were diagnosed with stage IV colorectal cancer between 2009 and 2013 and underwent elective resection of their primary tumors were included. The primary outcome was all-cause mortality depending on the occurrence of anastomotic leak. Secondary outcomes were the administration of and time to adjuvant chemotherapy, metastasectomy rate, and risk factors for leak. Of the 774 patients with stage IV colorectal cancer who were included, 71 (9.2%) developed anastomotic leaks. Anastomotic leak had a significant impact on the long-term survival of patients with colon cancer (p = 0.04) but not on those with rectal cancer (p = 0.91). Anastomotic leak was followed by the decreased administration of adjuvant chemotherapy in patients with colon cancer (p = 0.007) but not in patients with rectal cancer (p = 0.47). Finally, anastomotic leak had a detrimental impact on metastasectomy rates after colon cancer but not on resection rates of rectal cancer. Retrospective data on the selection criteria for primary tumor resection and metastatic tumor load were unavailable. The impact of anastomotic leak on patients differed between stage IV colon and rectal cancers. Survival and eligibility to receive chemotherapy and metastasectomy differed between patients with colon and rectal cancers. When planning for primary tumor resection, these factors should be considered.
Microphone Detects Boiler-Tube Leaks
NASA Technical Reports Server (NTRS)
Parthasarathy, S. P.
1985-01-01
Unit simple, sensitive, rugged, and reliable. Diaphragmless microphone detects leaks from small boiler tubes. Porous plug retains carbon granules in tube while allowing pressure changes to penetrate to granules. Has greater life expectancy than previous controllers and used in variety of hot corrosive atmospheres.
Nikolian, Vahagn C; Kamdar, Neil S; Regenbogen, Scott E; Morris, Arden M; Byrn, John C; Suwanabol, Pasithorn A; Campbell, Darrell A; Hendren, Samantha
2017-06-01
Anastomotic leak is a major source of morbidity in colorectal operations and has become an area of interest in performance metrics. It is unclear whether anastomotic leak is associated primarily with surgeons' technical performance or explained better by patient characteristics and institutional factors. We sought to establish if anastomotic leak could serve as a valid quality metric in colorectal operations by evaluating provider variation after adjusting for patient factors. We performed a retrospective cohort study of colorectal resection patients in the Michigan Surgical Quality Collaborative. Clinically relevant patient and operative factors were tested for association with anastomotic leak. Hierarchical logistic regression was used to derive risk-adjusted rates of anastomotic leak. Of 9,192 colorectal resections, 244 (2.7%) had a documented anastomotic leak. The incidence of anastomotic leak was 3.0% for patients with pelvic anastomoses and 2.5% for those with intra-abdominal anastomoses. Multivariable analysis showed that a greater operative duration, male sex, body mass index >30 kg/m 2 , tobacco use, chronic immunosuppressive medications, thrombocytosis (platelet count >400 × 10 9 /L), and urgent/emergency operations were independently associated with anastomotic leak (C-statistic = 0.75). After accounting for patient and procedural risk factors, 5 hospitals had a significantly greater incidence of postoperative anastomotic leak. This population-based study shows that risk factors for anastomotic leak include male sex, obesity, tobacco use, immunosuppression, thrombocytosis, greater operative duration, and urgent/emergency operation; models including these factors predict most of the variation in anastomotic leak rates. This study suggests that anastomotic leak can serve as a valid metric that can identify opportunities for quality improvement. Copyright © 2017 Elsevier Inc. All rights reserved.
Management of Anterior Skull Base Defect Depending on Its Size and Location
Bernal-Sprekelsen, Manuel; Rioja, Elena; Enseñat, Joaquim; Enriquez, Karla; Viscovich, Liza; Agredo-Lemos, Freddy Enrique; Alobid, Isam
2014-01-01
Introduction. We present our experience in the reconstruction of these leaks depending on their size and location. Material and Methods. Fifty-four patients who underwent advanced skull base surgery (large defects, >20 mm) and 62 patients with CSF leaks of different origin (small, 2–10 mm, and midsize, 11–20 mm, defects) were included in the retrospective study. Large defects were reconstructed with a nasoseptal pedicled flap positioned on fat and fascia lata. In small and midsized leaks. Fascia lata in an underlay position was used for its reconstruction covered with mucoperiosteum of either the middle or the inferior turbinate. Results. The most frequent etiology for small and midsized defects was spontaneous (48.4%), followed by trauma (24.2%), iatrogenic (5%). The success rate after the first surgical reconstruction was 91% and 98% in large skull base defects and small/midsized, respectively. Rescue surgery achieved 100%. Conclusions. Endoscopic surgery for any type of skull base defect is the gold standard. The size of the defects does not seem to play a significant role in the success rate. Fascia lata and mucoperiosteum of the turbinate allow a two-layer reconstruction of small and midsized defects. For larger skull base defects, a combination of fat, fascia lata, and nasoseptal pedicled flaps provides a successful reconstruction. PMID:24895567
Propionate induces cell swelling and K+ accumulation in shark rectal gland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feldman, G.M.; Ziyadeh, F.N.; Mills, J.W.
1989-08-01
Small organic anions have been reported to induce cell solute accumulation and swelling. To investigate the mechanism of swelling, we utilized preparations of rectal gland cells from Squalus acanthias incubated in medium containing propionate. Propionate causes cells to swell by diffusing across membranes in its nonionic form, acidifying cell contents, and activating the Na+-H+ antiporter. The Na+-H+ exchange process tends to correct intracellular pH (pHi), and thus it maintains a favorable gradient for propionic acid diffusion and allows propionate to accumulate. Activation of the Na+-H+ antiport also facilitates Na+ entry into the cell and Nai accumulation. At the same timemore » Na+-K+-ATPase activity, unaffected by propionate, replaces Nai with Ki, whereas the K+ leak rate, decreased by propionate, allows Ki to accumulate. As judged by {sup 86}Rb+ efflux, the reduction in K+ leak was not due to propionate-induced cell acidification or reduction in Cli concentration. Despite inducing cell swelling, propionate did not disrupt cell structural elements and F actin distribution along cell membranes.« less
40 CFR 86.328-79 - Leak checks.
Code of Federal Regulations, 2013 CFR
2013-07-01
... flows may be used to estimate the in-use flow rates. (3) The sample probe and the connection between the sample probe and valve V2 (Figure D79-1) may be excluded from the leak check. (b) Pressure side leak...
40 CFR 86.328-79 - Leak checks.
Code of Federal Regulations, 2012 CFR
2012-07-01
... flows may be used to estimate the in-use flow rates. (3) The sample probe and the connection between the sample probe and valve V2 (Figure D79-1) may be excluded from the leak check. (b) Pressure side leak...
40 CFR 86.328-79 - Leak checks.
Code of Federal Regulations, 2010 CFR
2010-07-01
... flows may be used to estimate the in-use flow rates. (3) The sample probe and the connection between the sample probe and valve V2 (Figure D79-1) may be excluded from the leak check. (b) Pressure side leak...
40 CFR 86.328-79 - Leak checks.
Code of Federal Regulations, 2011 CFR
2011-07-01
... flows may be used to estimate the in-use flow rates. (3) The sample probe and the connection between the sample probe and valve V2 (Figure D79-1) may be excluded from the leak check. (b) Pressure side leak...
Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability
Hunsbedt, A.; Boardman, C.E.
1995-04-11
A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor is disclosed. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo`s structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated. 5 figures.
Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability
Hunsbedt, Anstein; Boardman, Charles E.
1995-01-01
A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo's structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated.
de la Portilla, Fernando; Builes, Sergio; García-Novoa, Alejandra; Espín, Eloy; Kreisler, Esther; Enríquez-Navascues, José María; Biondo, Sebastiano; Codina, Antonio
2018-04-01
Currently, there is growing interest in analyzing the results from surgical units and the implementation of quality standards in order to identify good healthcare practices. Due to this fact, the Spanish Association of Coloproctology (AECP) has developed a unit accreditation program that contemplates basic standards. The aim of this article is to evaluate and analyze the specific quality indicators for the surgical treatment of colorectal cancer, established by the program. Data were collected from colorectal units during the accreditation process. We analyzed prospectively collected data from elective colorectal surgeries at 18 Spanish coloproctology units during the period 2013-2017. Three main and four secondary quality indicators were considered. Colon and rectal surgeries were analyzed independently; furthermore, results were compared according to surgical approach. A total of 3090 patients were included in the analysis. The global anastomotic leak rate was 7.8% (6.6% colon vs 10.6% rectum), while the surgical site infection rate was 12.6% (11.4% colon vs 14.8% rectum). Overall 30-day mortality was 2.3%, and anastomotic leak-related mortality was 10.2%. There were higher surgical site infection and mortality rates in the patients operated by open approach, however there was no difference in the anastomotic leak rate when compared with minimally invasive approaches. The evaluation of these results has determined optimal quality indices for the units accredited in the treatment of colorectal cancer. Furthermore, it allows us to establish realistic references in our country, thereby providing a better understanding and comparison of outcomes. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Routine Leak Testing in Colorectal Surgery in the Surgical Care and Outcomes Assessment Program
Kwon, Steve; Morris, Arden; Billingham, Richard; Frankhouse, Joseph; Horvath, Karen; Johnson, Morrie; McNevin, Shane; Simons, Anthony; Symons, Rebecca; Steele, Scott; Thirlby, Richard; Whiteford, Mark; Flum, David R.
2014-01-01
Objective To evaluate the effect of routine anastomotic leak testing (performed to screen for leaks) vs selective testing (performed to evaluate for a suspected leak in a higher-risk or technically difficult anastomosis) on outcomes in colorectal surgery because the value of provocative testing of colorectal anastomoses as a quality improvement metric has yet to be determined. Design Observational, prospectively designed cohort study. Setting Data from Washington state’s Surgical Care and Outcomes Assessment Program (SCOAP). Patients Patients undergoing elective left-sided colon or rectal resections at 40 SCOAP hospitals from October 1, 2005, to December 31, 2009. Interventions Use of leak testing, distinguishing procedures that were performed at hospitals where leak testing was selective (<90% use) or routine (≥90% use) in a given calendar quarter. Main Outcome Measure Adjusted odds ratio of a composite adverse event (CAE) (unplanned postoperative intervention and/or in-hospital death) at routine testing hospitals. Results Among 3449 patients (mean [SD] age, 58.8[14.8] years; 55.0% women), the CAE rate was 5.5%. Provocative leak testing increased (from 56% in the starting quarter to 76% in quarter 16) and overall rates of CAE decreased (from 7.0% in the starting quarter to 4.6% in quarter 16; both P ≤ .01) over time. Among patients at hospitals that performed routine leak testing, we found a reduction of more than 75% in the adjusted risk of CAEs (odds ratio, 0.23; 95% CI, 0.05–0.99). Conclusion Routine leak testing of left-sided colorectal anastomoses appears to be associated with a reduced rate of CAEs within the SCOAP network and meets many of the criteria of a worthwhile quality improvement metric. PMID:22508778
Routine leak testing in colorectal surgery in the Surgical Care and Outcomes Assessment Program.
Kwon, Steve; Morris, Arden; Billingham, Richard; Frankhouse, Joseph; Horvath, Karen; Johnson, Morrie; McNevin, Shane; Simons, Anthony; Symons, Rebecca; Steele, Scott; Thirlby, Richard; Whiteford, Mark; Flum, David R
2012-04-01
To evaluate the effect of routine anastomotic leak testing (performed to screen for leaks) vs selective testing (performed to evaluate for a suspected leak in a higher-risk or technically difficult anastomosis) on outcomes in colorectal surgery because the value of provocative testing of colorectal anastomoses as a quality improvement metric has yet to be determined. Observational, prospectively designed cohort study. Data from Washington state's Surgical Care and Outcomes Assessment Program (SCOAP). Patients undergoing elective left-sided colon or rectal resections at 40 SCOAP hospitals from October 1, 2005, to December 31, 2009. Use of leak testing, distinguishing procedures that were performed at hospitals where leak testing was selective (<90% use) or routine (≥ 90% use) in a given calendar quarter. Adjusted odds ratio of a composite adverse event (CAE) (unplanned postoperative intervention and/or in-hospital death) at routine testing hospitals. Among 3449 patients (mean [SD] age, 58.8 [14.8] years; 55.0% women), the CAE rate was 5.5%. Provocative leak testing increased (from 56% in the starting quarter to 76% in quarter 16) and overall rates of CAE decreased (from 7.0% in the starting quarter to 4.6% in quarter 16; both P ≤ .01) over time. Among patients at hospitals that performed routine leak testing, we found a reduction of more than 75% in the adjusted risk of CAEs (odds ratio, 0.23; 95% CI, 0.05-0.99). Routine leak testing of left-sided colorectal anastomoses appears to be associated with a reduced rate of CAEs within the SCOAP network and meets many of the criteria of a worthwhile quality improvement metric.
Code of Federal Regulations, 2013 CFR
2013-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2012 CFR
2012-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2014 CFR
2014-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Assessment of Remote Sensing Technologies for Location of Hydrogen and Helium Leaks
NASA Technical Reports Server (NTRS)
Sellar, R. Glenn; Wang, Danli
2000-01-01
The objective of this initial phase of this research effort is to: 1) Evaluate remote sensing technologies for location of leaks of gaseous molecular hydrogen (H2) and gaseous helium (He) in air, for space transportation applications; and 2) Develop a diffusion model that predicts concentration of H2 or He gas as a function of leak rate and distance from the leak.
Code of Federal Regulations, 2010 CFR
2010-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2011 CFR
2011-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
A multicenter study of routine versus selective intraoperative leak testing for sleeve gastrectomy.
Bingham, Jason; Kaufman, Jedediah; Hata, Kai; Dickerson, James; Beekley, Alec; Wisbach, Gordon; Swann, Jacob; Ahnfeldt, Eric; Hawkins, Devon; Choi, Yong; Lim, Robert; Martin, Matthew
2017-09-01
Staple line leaks after sleeve gastrectomy are dreaded complications. Many surgeons routinely perform an intraoperative leak test (IOLT) despite little evidence to validate the reliability, clinical benefit, and safety of this procedure. To determine the efficacy of IOLT and if routine use has any benefit over selective use. Eight teaching hospitals, including private, university, and military facilities. A multicenter, retrospective analysis over a 5-year period. The efficacy of the IOLT for identifying unsuspected staple line defects and for predicting postoperative leaks was evaluated. An anonymous survey was also collected reflecting surgeons' practices and beliefs regarding IOLT. From January 2010 through December 2014, 4284 patients underwent sleeve gastrectomy. Of these, 37 patients (.9%) developed a postoperative leak, and 2376 patients (55%) received an IOLT. Only 2 patients (0.08%) had a positive finding. Subsequently, 21 patients with a negative IOLT developed a leak. IOLT demonstrated a sensitivity of only 8.7%. There was a nonsignificant trend toward increased leak rates when an IOLT was performed versus when IOLT was not performed. Leak rates were not statistically different between centers that routinely perform IOLT versus those that selectively perform IOLT. Routine IOLT had very poor sensitivity and was negative in 91% of patients who later developed postoperative leaks. The use of IOLT was not associated with a decrease in the incidence of postoperative leaks, and routine IOLT had no benefit over selective leak testing. IOLT should not be used as a quality indicator or "best practice" for bariatric surgery. Published by Elsevier Inc.
Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor
NASA Astrophysics Data System (ADS)
Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.
2017-04-01
Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.
A voice-actuated wind tunnel model leak checking system
NASA Technical Reports Server (NTRS)
Larson, William E.
1989-01-01
A computer program has been developed that improves the efficiency of wind tunnel model leak checking. The program uses a voice recognition unit to relay a technician's commands to the computer. The computer, after receiving a command, can respond to the technician via a voice response unit. Information about the model pressure orifice being checked is displayed on a gas-plasma terminal. On command, the program records up to 30 seconds of pressure data. After the recording is complete, the raw data and a straight line fit of the data are plotted on the terminal. This allows the technician to make a decision on the integrity of the orifice being checked. All results of the leak check program are stored in a database file that can be listed on the line printer for record keeping purposes or displayed on the terminal to help the technician find unchecked orifices. This program allows one technician to check a model for leaks instead of the two or three previously required.
Robust Soft Textile Transfer Case for Contaminated Materials
2017-08-28
least thirty-six pounds per square inch; remain leak -proof after a thirty foot drop when filled with water to at least a ninety-eight percent...shipping standards for use require a leak -proof seal without an allowance for pressure relief. While the container would likely never need to be re...after the insertion of the contents; be puncture Attorney Docket No. 300153 3 of 17 resistant; be leak -proof at a hydrostatic pressure of at
Development of a Miniaturized and Portable Methane Analyzer for Natural Gas Leak Walking Surveys
NASA Astrophysics Data System (ADS)
Huang, Y. W.; Leen, J. B.; Gupta, M.; Baer, D. S.
2016-12-01
Traditional natural gas leak walking surveys have been conducted with devices that are based on technologies such as flame ionization detector (FID), IR-based spectrometer and IR camera. The sensitivity is typically on the ppm level. The low sensitivity means the device cannot pick up leaks far from it, and more time is spent surveying the area before pinpointing the leak location. A miniaturized methane analyzer has been developed to significantly improve the sensitivity of the device used in walking surveys to detect natural gas leaks at greater distance. ABB/LGR's patented Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) is utilized to offer rugged and highly sensitive methane detection in a portable package. The miniaturized package weighs 13.5 lb, with a 4-hour rechargeable battery inside. The precision of the analyzer for methane is 2 ppb at 1 second. The analyzer operates at 10 Hz and its flow response time is 3 seconds for measurements through a 1-meter long sampling wand to registering on the data stream. The data can be viewed in real-time on a tablet or a smartphone. The compact and simplified package of the methane analyzer allows for more efficient walking surveys. It also allows for other applications that require low-power, low-weight and a portable package. We present data from walking surveys to demonstrate its ability to detect methane leaks.
Rapid, Vehicle-Based Identification of Location and Magnitude of Urban Natural Gas Pipeline Leaks.
von Fischer, Joseph C; Cooley, Daniel; Chamberlain, Sam; Gaylord, Adam; Griebenow, Claire J; Hamburg, Steven P; Salo, Jessica; Schumacher, Russ; Theobald, David; Ham, Jay
2017-04-04
Information about the location and magnitudes of natural gas (NG) leaks from urban distribution pipelines is important for minimizing greenhouse gas emissions and optimizing investment in pipeline management. To enable rapid collection of such data, we developed a relatively simple method using high-precision methane analyzers in Google Street View cars. Our data indicate that this automated leak survey system can document patterns in leak location and magnitude within and among cities, even without wind data. We found that urban areas with prevalent corrosion-prone distribution lines (Boston, MA, Staten Island, NY, and Syracuse, NY), leaked approximately 25-fold more methane than cities with more modern pipeline materials (Burlington, VT, and Indianapolis, IN). Although this mobile monitoring method produces conservative estimates of leak rates and leak counts, it can still help prioritize both leak repairs and replacement of leak-prone sections of distribution lines, thus minimizing methane emissions over short and long terms.
NASA Technical Reports Server (NTRS)
Nuss, H. E.
1975-01-01
The measuring and evaluation procedure for the determination of leak rates of satellite subsystems with a quadrupole mass spectrometer, and the results of the residual gas analysis are described. The method selected for leak rate determination was placing the system into a vacuum chamber and furnishing the chamber with a mass spectrometer and calibrated leaks. The residual gas of a thermal vacuum test facility, in which the thermal balance test radiation input was simulated by a heated canister, was analyzed with the mass spectrometer in the atomic mass unit range up to 300 amu. In addition to the measurements during the space environment tests, mass spectrometric studies were performed with samples of spacecraft materials. The studies were carried out during tests for the projects HELIOS, AEROS B and SYMPHONIE.
Real-time electronic monitoring of a pitted and leaking gas gathering pipeline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asperger, R.G.; Hewitt, P.G.
1986-08-01
Hydrogen patch, flush electrical resistance, and flush linear polarization proves wre used with flush coupons to monitor corrosion rates in a pitted and leaking sour gas gathering line. Four inhibitors were evaluated in stopping the leaks. Inhibitor residuals and the amount and ratio of water and condensate in the lines were measured at five locations along the line. The best inhibitor reduced reduced the pit-leak frequency by over a factor of 10. Inhibitor usage rate was optimized using the hydrogen patch current as a measure of the instantaneous corrosion rate. Improper pigging was identified as a cause of corrosion transients.more » This problem is discussed in relation to the pigging of pipelines in stratified flow where moving fluids are the carriers for continuously injected corrosion inhibitors.« less
NASA Astrophysics Data System (ADS)
Pathan, F. S.; Khan, Z.; Semwal, P.; Raval, D. C.; Joshi, K. S.; Thankey, P. L.; Dhanani, K. R.
2008-05-01
Steady State Super-conducting (SST-1) Tokamak is in commissioning stage at Institute for Plasma Research. Vacuum chamber of SST-1 Tokamak consists of 1) Vacuum vessel, an ultra high vacuum (UHV) chamber, 2) Cryostat, a high vacuum (HV) chamber. Cryostat encloses the liquid helium cooled super-conducting magnets (TF and PF), which require the thermal radiation protection against room temperature. Liquid nitrogen (LN2) cooled panels are used to provide thermal shield around super-conducting magnets. During operation, LN2 panels will be under pressurized condition and its surrounding (cryostat) will be at high vacuum. Hence, LN2 panels must have very low leak rate. This paper describes an experiment to study the behaviour of the leaks in LN2 panels during sniffer test and pressure drop test using helium gas.
NASA Technical Reports Server (NTRS)
Rinehart, Maegan L.
2011-01-01
The purpose of this activity is to provide the Mechanical Components Test Facility (MCTF) with the capability to obtain electronic leak test and proof pressure data, Payload and Components Real-time Automated Test System (PACRATS) data acquisition software will be utilized to display real-time data. It will record leak rates and pressure/vacuum level(s) simultaneously. This added functionality will provide electronic leak test and pressure data at specified sampling frequencies. Electronically stored data will provide ES61 with increased data security, analysis, and accuracy. The tasks performed in this procedure are to verify PACRATS only, and are not intended to provide verifications for MCTF equipment.
Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James
2017-01-01
USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a guide for method development of container closure integrity tests. LAY ABSTRACT: The new USP 39 <1207>, "Package Integrity Evaluation-Sterile Products", states in section 3.4.1: "tracer gas tests performed using … laser-based gas headspace analysis [have] been shown to be sensitive enough to quantitatively analyze leakage through the smallest leak paths found to pose the smallest chance of liquid leakage or microbial ingress in rigid packaging." In addition, USP <1207> also states that "for such methods, the limit of detection can be mathematically predicted on the basis of gas flow kinetics." Using the above statements as a foundation, this paper presents a theoretical basis for predicting the gas ingress through well-defined defects in product vials sealed under a variety of headspace conditions. These calculated predictions were experimentally validated by comparing them to measurements of changes in the headspace oxygen content or total pressure for several different positive controls using laser-based headspace analysis. The results demonstrated that laser-based headspace analysis can, by readily differentiating between negative controls and positive controls with a range of defect sizes on the micron scale, be used to assess container closure integrity. The work also demontrated that caution must be used when attempting to correlate a leak rate to an idealized defect-size parameter. © PDA, Inc. 2017.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-16
...,000 gallons being typical. The licensee maintains a pool leak surveillance program. The pool water leak surveillance program continues to monitor the pool water evaporation rate, the pool water make-up volume, and pool water radioactivity. The pool leak surveillance program indicated that approximately 2...
Treatment of gastric leaks with coated self-expanding stents after sleeve gastrectomy.
Serra, Carlos; Baltasar, Aniceto; Andreo, Luis; Pérez, Nieves; Bou, Rafael; Bengochea, Marcelo; Chisbert, Juan José
2007-07-01
Duodenal switch (DS) is one of the most effective techniques for the treatment of morbid obesity and its co-morbidities, with mortality rate <1%, but with 9.4% morbidity rates (6.5% due to leaks). In our experience, leaks of the staple-line after sleeve gastrectomy (SG) are the most frequent sites of fistula formation and conservative treatment usually takes a long time. We present our experience in the treatment of gastric leaks with coated self-expandable stents (CSES). 6 patients had gastric leaks at the gastroesophageal (GE) junction after SG or DS. One patient had a symptomatic gastro-bronchial fistula. Stents were placed by the interventional radiologist under fluoroscopic control and removed endoscopically. In one case, we used an uncoated Wallstent. In two patients, percutaneous microcoil embolization of the fistula was added. The patient treated with the Wallstent required a total gastrectomy 6 months after placement of the uncovered stent. In the other 5 patients, coated stents were successfully removed and the gastric leaks completely sealed. CSES are proposed as an alternative therapeutic option for the management of GE junction leaks in bariatric surgery with good results in terms of morbidity and survival.
Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning
2012-01-01
In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point’s position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate. PMID:22368464
Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning
2012-01-01
In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point's position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.
Neonatal air leak syndrome and the role of high-frequency ventilation in its prevention.
Jeng, Mei-Jy; Lee, Yu-Sheng; Tsao, Pei-Chen; Soong, Wen-Jue
2012-11-01
Air leak syndrome includes pulmonary interstitial emphysema, pneumothorax, pneumomediastinum, pneumopericardium, pneumoperitoneum, subcutaneous emphysema, and systemic air embolism. The most common cause of air leak syndrome in neonates is inadequate mechanical ventilation of the fragile and immature lungs. The incidence of air leaks in newborns is inversely related to the birth weight of the infants, especially in very-low-birth-weight and meconium-aspirated infants. When the air leak is asymptomatic and the infant is not mechanically ventilated, there is usually no specific treatment. Emergent needle aspiration and/or tube drainage are necessary in managing tension pneumothorax or pneumopericardium with cardiac tamponade. To prevent air leak syndrome, gentle ventilation with low pressure, low tidal volume, low inspiratory time, high rate, and judicious use of positive end expiratory pressure are the keys to caring for mechanically ventilated infants. Both high-frequency oscillatory ventilation (HFOV) and high-frequency jet ventilation (HFJV) can provide adequate gas exchange using extremely low tidal volume and supraphysiologic rate in neonates with acute pulmonary dysfunction, and they are considered to have the potential to reduce the risks of air leak syndrome in neonates. However, there is still no conclusive evidence that HFOV or HFJV can help to reduce new air leaks in published neonatal clinical trials. In conclusion, neonatal air leaks may present as a thoracic emergency requiring emergent intervention. To prevent air leak syndrome, gentle ventilations are key to caring for ventilated infants. There is insufficient evidence showing the role of HFOV and HFJV in the prevention or reduction of new air leaks in newborn infants, so further investigation will be necessary for future applications. Copyright © 2012. Published by Elsevier B.V.
García-Granero, Eduardo; Navarro, Francisco; Cerdán Santacruz, Carlos; Frasson, Matteo; García-Granero, Alvaro; Marinello, Franco; Flor-Lorente, Blas; Espí, Alejandro
2017-11-01
Our aim was to assess whether the individual surgeon is an independent risk factor for anastomotic leak in double-stapled colorectal anastomosis after left colon and rectal cancer resection. This retrospective analysis of a prospectively collected database consists of a consecutive series of 800 patients who underwent an elective left colon and rectal resection with a colorectal, double-stapled anastomosis between 1993 and 2009 in a specialized colorectal unit of a tertiary hospital with 7 participating surgeons. The main outcome variable was anastomotic leak, defined as leak of luminal contents from a colorectal anastomosis between 2 hollow viscera diagnosed radiologically, clinically, endoscopically, or intraoperatively. Pelvic abscesses were also considered to be an anastomotic leak. Radiologic examination was performed when there was clinical suspicion of leak. Anastomotic leak occurred in 6.1% of patients, of which 33 (67%) were treated operatively, 6 (12%) with radiologic drains, and 10 (21%) by medical treatment. Postoperative mortality rate was 2.9% for the whole group of 800 patients. In patients with anastomotic leak, mortality rate increased up to 16% vs 2.0% in patients without anastomotic leak (P < .0001). At multivariate analysis, rectal location of tumor, male sex, bowel obstruction preoperatively, tobacco use, diabetes, perioperative transfusion, and the individual surgeon were independent risk factors for anastomotic leak. The surgeon was the most important factor (mean odds ratio 4.9; range 1.0 to 13.5). The variance of anastomotic leak between the different surgeons was 0.56 in the logit scale. The individual surgeon is an independent risk factor for leakage in double-stapled, colorectal, end-to-end anastomosis after oncologic left-sided colorectal resection. Copyright © 2017 Elsevier Inc. All rights reserved.
Comparative evaluation of three shaft seals proposed for high performance turbomachinery
NASA Technical Reports Server (NTRS)
Hendricks, R. C.
1982-01-01
Experimental pressure profiles and leak rate characteristics for three shaft seal prototype model configurations proposed for the space shuttle turbopump were assessed in the concentric and fully eccentric, to point of rub, positions without the effects of rotation. The parallel-cylindrical configuration has moderate to good stiffness with a higher leak rate. It represents a simple concept, but for practical reasons and possible increases in stability, all such seals should be conical-convergent. The three-stepdown-sequential, parallel-cylindrical seal is converging and represents good to possible high stiffness when fluid separation occurs, with a significant decrease in leak rate. Such seals can be very effective. The three-stepdown-sequential labyrinth seal of 33-teeth (i.e., 12-11-10 teeth from inlet to exit) provides excellent leak control but usually has very poor stiffness, depending on cavity design. The seal is complex and not recommended for dynamic control.
Anselmetti, Giovanni Carlo; Zoarski, Gregg; Manca, Antonio; Masala, Salvatore; Eminefendic, Haris; Russo, Filippo; Regge, Daniele
2008-01-01
The aim of this study was to assess the feasibility of and venous leakage reduction in percutaneous vertebroplasty (PV) using a new high-viscosity bone cement (PMMA). PV has been used effectively for pain relief in osteoporotic and malignant vertebral fractures. Cement extrusion is a common problem and can lead to complications. Sixty patients (52 female; mean age, 72.2 +/- 7.2) suffering from osteoporosis (46), malignancy (12), and angiomas (2), divided into two groups (A and B), underwent PV on 190 vertebrae (86 dorsal, 104 lumbar). In Group A, PV with high-viscosity PMMA (Confidence, Disc-O-Tech, Israel) was used. This PMMA was injected by a proprietary delivery system, a hydraulic saline-filled screw injector. In Group B, a standard low-viscosity PMMA was used. Postprocedural CT was carried out to detect PMMA leakages and complications. Fisher's exact test and Wilcoxon rank test were used to assess significant differences (p < 0.05) in leakages and to evaluate the clinical outcome. PV was feasible, achieving good clinical outcome (p < 0.0001) without major complications. In Group A, postprocedural CT showed an asymptomatic leak in the venous structures of 8 of 98 (8.2%) treated vertebrae; a discoidal leak occurred in 6 of 98 (6.1%). In Group B, a venous leak was seen in 38 of 92 (41.3%) and a discoidal leak in 12 of 92 (13.0%). Reduction of venous leak obtained by high-viscosity PMMA was highly significant (p < 0.0001), whereas this result was not significant (p = 0.14) related to the disc. The high-viscosity PMMA system is safe and effective for clinical use, allowing a significant reduction of extravasation rate and, thus, leakage-related complications.
Dua, Kulwinder S; Latif, Sahibzada U; Yang, Juliana F; Fang, Tom C; Khan, Abdul; Oh, Young
2014-10-01
Fully covered esophageal self-expandable metal stents (SEMSs) are potentially removable but can be associated with high migration rates. For precise positioning, non-foreshortening SEMSs are preferred. Recently, a new fully covered non-foreshortening SEMS with anti-migration features was introduced. To evaluate the efficacy and safety of this new esophageal SEMS. Retrospective study. Single, tertiary-care center. Consecutive patients with malignant and benign strictures with dysphagia grade of ≥3 and patients with fistulas/leaks were studied. Stent placement and removal. Technical success in stent deployment/removal, efficacy in relieving dysphagia and sealing fistulas/leaks, and adverse events. Forty-three stents were placed in 35 patients (mean [± standard deviation] age 65 ± 11 years; 31 male), 24 for malignant and 11 for benign (5 strictures, 6 leaks) indications. Technical success in precise SEMS placement was 100%. The after-stent dysphagia grade improved significantly (at 1 week: 1.5 ± 0.7; at 4 weeks: 1.2 ± 0.4; baseline: 3.8 ± 0.4; P < .0001). Twenty stents were removed for clinical indications, with technical success of 100%. All leaks sealed after SEMS placement and did not recur after stent removal. All benign strictures recurred after stent removal. Adverse events included migration (14%), chest pain (11%), and dysphagia from tissue hyperplasia (6%). There was no stent-related mortality. Nonrandomized, single-center study. The new esophageal SEMS was effective in relieving malignant dysphagia, allowed for precise placement, and was easily removable. It was effective in treating benign esophageal fistulas and leaks. Stent-related adverse events were acceptable. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Real-time imaging of methane gas leaks using a single-pixel camera.
Gibson, Graham M; Sun, Baoqing; Edgar, Matthew P; Phillips, David B; Hempler, Nils; Maker, Gareth T; Malcolm, Graeme P A; Padgett, Miles J
2017-02-20
We demonstrate a camera which can image methane gas at video rates, using only a single-pixel detector and structured illumination. The light source is an infrared laser diode operating at 1.651μm tuned to an absorption line of methane gas. The light is structured using an addressable micromirror array to pattern the laser output with a sequence of Hadamard masks. The resulting backscattered light is recorded using a single-pixel InGaAs detector which provides a measure of the correlation between the projected patterns and the gas distribution in the scene. Knowledge of this correlation and the patterns allows an image to be reconstructed of the gas in the scene. For the application of locating gas leaks the frame rate of the camera is of primary importance, which in this case is inversely proportional to the square of the linear resolution. Here we demonstrate gas imaging at ~25 fps while using 256 mask patterns (corresponding to an image resolution of 16×16). To aid the task of locating the source of the gas emission, we overlay an upsampled and smoothed image of the low-resolution gas image onto a high-resolution color image of the scene, recorded using a standard CMOS camera. We demonstrate for an illumination of only 5mW across the field-of-view imaging of a methane gas leak of ~0.2 litres/minute from a distance of ~1 metre.
Burlew, Clay Cothren; Moore, Ernest E; Cuschieri, Joseph; Jurkovich, Gregory J; Codner, Panna; Crowell, Kody; Nirula, Ram; Haan, James; Rowell, Susan E; Kato, Catherine M; MacNew, Heather; Ochsner, M Gage; Harrison, Paul B; Fusco, Cynthia; Sauaia, Angela; Kaups, Krista L
2011-02-01
Use of damage control surgery techniques has reduced mortality in critically injured patients but at the cost of the open abdomen. With the option of delayed definitive management of enteric injuries, the question of intestinal repair/anastomosis or definitive stoma creation has been posed with no clear consensus. The purpose of this study was to determine outcomes on the basis of management of enteric injuries in patients relegated to the postinjury open abdomen. Patients requiring an open abdomen after trauma from January 1, 2002 to December 31, 2007 were reviewed. Type of bowel repair was categorized as immediate repair, immediate anastomosis, delayed anastomosis, stoma and a combination. Logistic regression was used to determine independent effect of risk factors on leak development. During the 6-year study period, 204 patients suffered enteric injuries and were managed with an open abdomen. The majority was men (77%) sustaining blunt trauma (66%) with a mean age of 37.1 years±1.2 years and median Injury Severity Score of 27 (interquartile range=20-41). Injury patterns included 81 (40%) small bowel, 37 (18%) colonic, and 86 (42%) combined injuries. Enteric injuries were managed with immediate repair (58), immediate anastomosis (15), delayed anastomosis (96), stoma (10), and a combination (22); three patients died before definitive repair. Sixty-one patients suffered intra-abdominal complications: 35 (17%) abscesses, 15 (7%) leaks, and 11 (5%) enterocutaneous fistulas. The majority of patients with leaks had a delayed anastomosis; one patient had a right colon repair. Leak rate increased as one progresses toward the left colon (small bowel anastomoses, 3% leak rate; right colon, 3%; transverse colon, 20%; left colon, 45%). There were no differences in emergency department physiology, injury severity, transfusions, crystalloids, or demographic characteristics between patients with and without leak. Leak cases had higher 12-hour heart rate (148 vs. 125, p=0.02) and higher 12-hour base deficit (13.7 vs. 9.7, p=0.04), suggesting persistent shock and consequent hypoperfusion were related to leak development. There was a significant trend toward higher incidence of leak with closure day (χ for trend, p=0.01), with closure after day 5 having a four times higher likelihood of developing leak (3% vs. 12%, p=0.02). Repair or anastomosis of intestinal injuries should be considered in all patients. However, leak rate increases with fascial closure beyond day 5 and with left-sided colonic anastomoses. Investigating the physiologic basis for intestinal vulnerability of the left colon and in the open abdomen is warranted.
NASA Astrophysics Data System (ADS)
dos Santos, J. M. F.; Veloso, J. F. C. A.; Monteiro, C. M. B.
2004-01-01
We describe a simple experiment intended for didactic laboratory vacuum classes of undergraduate courses, using a helium leak detector. The helium throughput flowing into the vacuum volume due to the permeability of materials can be taken as a real leak, which can be measured with the helium leak detector. The experiment allows students to perform actual measurements of helium permeability constants of different materials, and access the dependence of the helium permeability throughput on the material thickness, area and helium pressure differential. As an example, a set of measurements are presented for Kapton foils, exhibiting results that are in good agreement with those presented in the literature.
Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.
Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz
2015-06-01
The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.
NASA Astrophysics Data System (ADS)
Gourdji, S. M.; Yadav, V.; Karion, A.; Mueller, K. L.; Conley, S.; Ryerson, T.; Nehrkorn, T.; Kort, E. A.
2018-04-01
Urban greenhouse gas (GHG) flux estimation with atmospheric measurements and modeling, i.e. the ‘top-down’ approach, can potentially support GHG emission reduction policies by assessing trends in surface fluxes and detecting anomalies from bottom-up inventories. Aircraft-collected GHG observations also have the potential to help quantify point-source emissions that may not be adequately sampled by fixed surface tower-based atmospheric observing systems. Here, we estimate CH4 emissions from a known point source, the Aliso Canyon natural gas leak in Los Angeles, CA from October 2015–February 2016, using atmospheric inverse models with airborne CH4 observations from twelve flights ≈4 km downwind of the leak and surface sensitivities from a mesoscale atmospheric transport model. This leak event has been well-quantified previously using various methods by the California Air Resources Board, thereby providing high confidence in the mass-balance leak rate estimates of (Conley et al 2016), used here for comparison to inversion results. Inversions with an optimal setup are shown to provide estimates of the leak magnitude, on average, within a third of the mass balance values, with remaining errors in estimated leak rates predominantly explained by modeled wind speed errors of up to 10 m s‑1, quantified by comparing airborne meteorological observations with modeled values along the flight track. An inversion setup using scaled observational wind speed errors in the model-data mismatch covariance matrix is shown to significantly reduce the influence of transport model errors on spatial patterns and estimated leak rates from the inversions. In sum, this study takes advantage of a natural tracer release experiment (i.e. the Aliso Canyon natural gas leak) to identify effective approaches for reducing the influence of transport model error on atmospheric inversions of point-source emissions, while suggesting future potential for integrating surface tower and aircraft atmospheric GHG observations in top-down urban emission monitoring systems.
Postoperative esophageal leak management with the Polyflex esophageal stent.
Freeman, Richard K; Ascioti, Anthony J; Wozniak, Thomas C
2007-02-01
Leak after esophageal anastomosis or perforation repair prolongs hospitalization, prevents oral hydration and nutrition, and can produce localized infection or sepsis. This investigation reviews our experience treating postoperative esophageal leaks with the Polyflex esophageal stent (Boston Scientific, Natick, Mass). Over a 30-month period, patients with a postoperative esophageal leak were treated with the Polyflex stent for leak occlusion. Leak occlusion was confirmed by means of esophagraphy. Patients were followed until their stent was removed and their esophageal leak had resolved. Twenty-one patients had 27 stents placed for leak occlusion after esophagectomy (n = 5), esophageal perforation (n = 5), surgical (n = 4) or endoscopic (n = 2) antireflux procedure, and esophageal diverticulectomy (n = 3) or myotomy (n = 2). The mean interval between surgical intervention and stent placement was 12 +/- 8 days (range, 3-31 days). Occlusion of the leak occurred in 20 patients. One patient experienced a dehiscence of the surgical esophageal perforation repair requiring esophageal diversion. Stent migration requiring repositioning (n = 3) or replacement (n = 4) occurred in 5 (24%) patients. Twenty (95%) stents were removed without residual leak (mean, 51 +/- 43 days; range, 15-175 days). One patient had a stricture after stent removal that required endoscopic dilatation. One patient in this series died. The Polyflex esophageal stent is an effective method for occluding a postoperative esophageal leak. It rapidly eliminates contamination of the mediastinum, pleura, and peritoneum; allows oral hydration and nutrition; and is easily removable. These stents also offer an appealing alternative to traditional esophageal diversion and subsequent reconstruction in patients with a persistent esophageal leak.
76 FR 39095 - Compatibility of Underground Storage Tank Systems With Biofuel Blends
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
... drinking water for nearly half of all Americans, the U.S. Environmental Protection Agency (EPA) regulates... components of the UST system, such as leak detection devices, sealants, and containment sumps, may not be... demonstration of compatibility. Some commenters suggested that EPA allow the National Work Group on Leak...
Determination of leakage areas in nuclear piping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keim, E.
1997-04-01
For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakagemore » areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.« less
Design of oil pipeline leak detection and communication system based on optical fiber technology
NASA Astrophysics Data System (ADS)
Tu, Yaqing; Chen, Huabo
1999-08-01
The integrity of oil pipeline is always a major concern of operators. Pipeline leak not only leads to loss of oil, but pollutes environment. A new pipeline leak detection and communication system based on optical fiber technology to ensure the pipeline reliability is presented. Combined direct leak detection method with an indirect one, the system will greatly reduce the rate of false alarm. According, to the practical features of oil pipeline,the pipeline communication system is designed employing the state-of-the-art optic fiber communication technology. The system has such feature as high location accuracy of leak detection, good real-time characteristic, etc. which overcomes the disadvantages of traditional leak detection methods and communication system effectively.
Scanning, standoff TDLAS leak imaging and quantification
NASA Astrophysics Data System (ADS)
Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.
2017-05-01
This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.
STS-113 workers search for oxygen leak
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- In the Payload Changeout Room, Launch Pad 39A, workers raise a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
STS-113 workers search for oxygen leak
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, ride a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
STS-113 workers search for oxygen leak
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, are on a platform in the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
Chern, Alexander; Hunter, Jacob B; Bennett, Marc L
2017-01-01
To determine if cranioplasty techniques following translabyrinthine approaches to the cerebellopontine angle are cost-effective. Retrospective case series. One hundred eighty patients with available financial data who underwent translabyrinthine approaches at a single academic referral center between 2005 and 2015. Cranioplasty with a dural substitute, layered fat graft, and a resorbable mesh plate secured with screws Main Outcome Measures: billing data was obtained for each patient's hospital course for translabyrinthine approaches and postoperative cerebrospinal fluid (CSF) leaks. One hundred nineteen patients underwent translabyrinthine approaches with an abdominal fat graft closure, with a median cost of $25759.89 (range, $15885.65-$136433.07). Sixty-one patients underwent translabyrinthine approaches with a dural substitute, abdominal fat graft, and a resorbable mesh for closure, with a median cost of $29314.97 (range, $17674.28-$111404.55). The median cost of a CSF leak was $50401.25 (range, $0-$384761.71). The additional cost of a CSF leak when shared by all patients who underwent translabyrinthine approaches is $6048.15. The addition of a dural substitute and a resorbable mesh plate after translabyrinthine approaches reduced the CSF leak from 12 to 1.9%, an 84.2% reduction, and a median savings per patient of $2932.23. Applying our cohort's billing data to previously published cranioplasty techniques, costs, and leak rate improvements after translabyrinthine approaches, all techniques were found to be cost-effective. Resorbable mesh cranioplasty is cost-effective at reducing CSF leaks after translabyrinthine approaches. Per our billing data and achieving the same CSF leak rate, cranioplasty costs exceeding $5090.53 are not cost-effective.
Eernisse, Errol P.; Peterson, Gary D.
1976-01-01
A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.
29 CFR 1910.254 - Arc welding and cutting.
Code of Federal Regulations, 2013 CFR
2013-07-01
... rated load with rated temperature rises where the temperature of the cooling air does not exceed 40 °C... work; magnetic work clamps shall be freed from adherent metal particles of spatter on contact surfaces... given to safety ground connections of portable machines. (4) Leaks. There shall be no leaks of cooling...
29 CFR 1910.254 - Arc welding and cutting.
Code of Federal Regulations, 2012 CFR
2012-07-01
... rated load with rated temperature rises where the temperature of the cooling air does not exceed 40 °C... work; magnetic work clamps shall be freed from adherent metal particles of spatter on contact surfaces... given to safety ground connections of portable machines. (4) Leaks. There shall be no leaks of cooling...
29 CFR 1910.254 - Arc welding and cutting.
Code of Federal Regulations, 2014 CFR
2014-07-01
... rated load with rated temperature rises where the temperature of the cooling air does not exceed 40 °C... work; magnetic work clamps shall be freed from adherent metal particles of spatter on contact surfaces... given to safety ground connections of portable machines. (4) Leaks. There shall be no leaks of cooling...
Pressure Decay Testing Methodology for Quantifying Leak Rates of Full-Scale Docking System Seals
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.; Daniels, Christopher C.; Wasowski, Janice L.; Garafolo, Nicholas G.; Penney, Nicholas; Steinetz, Bruce M.
2010-01-01
NASA is developing a new docking system to support future space exploration missions to low-Earth orbit and the Moon. This system, called the Low Impact Docking System, is a mechanism designed to connect the Orion Crew Exploration Vehicle to the International Space Station, the lunar lander (Altair), and other future Constellation Project vehicles. NASA Glenn Research Center is playing a key role in developing the main interface seal for this docking system. This seal will be relatively large with an outside diameter in the range of 54 to 58 in. (137 to 147 cm). As part of this effort, a new test apparatus has been designed, fabricated, and installed to measure leak rates of candidate full-scale seals under simulated thermal, vacuum, and engagement conditions. Using this test apparatus, a pressure decay testing and data processing methodology has been developed to quantify full-scale seal leak rates. Tests performed on untreated 54 in. diameter seals at room temperature in a fully compressed state resulted in leak rates lower than the requirement of less than 0.0025 lbm, air per day (0.0011 kg/day).
Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Miller, Jennifer R.; Birur, Gajanana; Bame, David; Mastropietro, A. J.; Bhandari, Pradeep; Lee, Darlene; Karlmann, Paul; Liu, Yuanming
2013-01-01
Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.
Thielen, Kent R; Sillery, John C; Morris, Jonathan M; Hoxworth, Joseph M; Diehn, Felix E; Wald, John T; Rosebrock, Richard E; Yu, Lifeng; Luetmer, Patrick H
2015-03-01
Precise localization and understanding of the origin of spontaneous high-flow spinal CSF leaks is required prior to targeted treatment. This study demonstrates the utility of ultrafast dynamic CT myelography for the precise localization of high-flow CSF leaks caused by spiculated spinal osteophytes. This study reports a series of 14 patients with high-flow CSF leaks caused by spiculated spinal osteophytes who underwent ultrafast dynamic CT myelography between March 2009 and December 2010. There were 10 male and 4 female patients, with an average age of 49 years (range 37-74 years). The value of ultrafast dynamic CT myelography in depicting the CSF leak site was qualitatively assessed. In all 14 patients, ultrafast dynamic CT myelography was technically successful at precisely demonstrating the site of the CSF leak, the causative spiculated osteophyte piercing the dura, and the relationship of the implicated osteophyte to adjacent structures. Leak sites included 3 cervical, 11 thoracic, and 0 lumbar levels, with 86% of the leaks occurring from C-5 to T-7. Information obtained from the ultrafast dynamic CT myelogram was considered useful in all treated CSF leaks. Spinal osteophytes piercing the dura are a more frequent cause of high-flow CSF leaks than previously recognized. Ultrafast dynamic CT myelography adds value beyond standard dynamic myelography or digital subtraction myelography in the diagnosis and anatomical characterization of high-flow spinal CSF leaks caused by these osteophytes. This information allows for appropriate planning for percutaneous or surgical treatment.
Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks
NASA Technical Reports Server (NTRS)
2013-01-01
In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.
Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey
2017-08-01
The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2015-01-01
The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.
Rodeghiero, Mirco; Niinemets, Ulo; Cescatti, Alessandro
2007-08-01
Estimates of leaf gas-exchange characteristics using standard clamp-on leaf chambers are prone to errors because of diffusion leaks. While some consideration has been given to CO(2) diffusion leaks, potential water vapour diffusion leaks through chamber gaskets have been neglected. We estimated diffusion leaks of two clamp-on Li-Cor LI-6400 (Li-Cor, Inc., Lincoln, NE, USA) leaf chambers with polymer foam gaskets and enclosing either 2 or 6 cm(2) leaf area, and conducted a sensitivity analysis of the diffusion leak effects on Farquhar et al. photosynthesis model parameters - the maximum carboxylase activity of ribulose 1 x 5-bisphosphate carboxylase/oxygenase (Rubisco) (V(cmax)), capacity for photosynthetic electron transport (J(max)) and non-photorespiratory respiration rate in light (R(d)). In addition, net assimilation rate (A(n)) versus intercellular CO(2) (C(i)) responses were measured in leaves of Mediterranean evergreen species Quercus ilex L. enclosing the whole leaf chamber in a polyvinyl fluoride bag flushed with the exhaust air of leaf chamber, thereby effectively reducing the CO(2) and water vapour gradients between ambient air and leaf chamber. For the empty chambers, average diffusion leak for CO(2), K(CO2), (molar flow rate corresponding to unit CO(2) mole fraction difference) was ca. 0.40 micromol s(-1). K(CO2) increased ca. 50% if a dead leaf was clamped between the leaf chamber. Average diffusion leak for H(2)O was ca. 5- to 10-fold larger than the diffusion leak for CO(2). Sensitivity analyses demonstrated that the consequence of a CO(2) diffusion leak was apparent enhancement of A(n) at high CO(2) mole fraction and reduction at lower CO(2) mole fraction, and overall compression of C(i) range. As the result of these modifications, Farquhar et al. model parameters were overestimated. The degree of overestimation increased in the order of V(cmax) < J(max) < R(d), and was larger for smaller chambers and for leaves with lower photosynthetic capacity, leading to overestimation of all three parameters by 70-290% for 2 cm(2), and by 10-60% for 6 cm(2) chamber. Significant diffusion corrections (5-36%) were even required for leaves with high photosynthetic capacity measured in largest chamber. Water vapour diffusion leaks further enhanced the overestimation of model parameters. For small chambers and low photosynthetic capacities, apparent C(i) was simulated to decrease with increasing A(n) because of simultaneous CO(2) and H(2)O diffusion leaks. Measurements in low photosynthetic capacity Quercus ilex leaves enclosed in 2 cm(2) leaf chamber exhibited negative apparent C(i) values at highest A(n). For the same leaves measured with the entire leaf chamber enclosed in the polyvinyl fluoride bag, C(i) and A(n) increased monotonically. While the measurements without the bag could be corrected for diffusion leaks, the required correction in A(n) and transpiration rates was 100-500%, and there was large uncertainty in Farquhar et al. model parameters derived from 'corrected'A(n)/C(i) response curves because of uncertainties in true diffusion leaks. These data demonstrate that both CO(2) and water vapour diffusion leaks need consideration in measurements with clamp-on leaf cuvettes. As plants in natural environments are often characterized by low photosynthetic capacities, cuvette designs need to be improved for reliable measurements in such species.
Yabe, Shuntaro; Kato, Hironari; Mizukawa, Sho; Akimoto, Yutaka; Uchida, Daisuke; Seki, Hiroyuki; Tomoda, Takeshi; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki
2017-05-01
Endoscopic procedures are used as first-line treatment for bile leak after hepatobiliary surgery. Advances have been made in endoscopic techniques and devices, but few reports have described the effectiveness of endoscopic procedures and the management principles based on severity of bile leak. We evaluated the effectiveness of an endoscopic procedure for the treatment of bile leak after hepatobiliary surgery. Fifty-eight patients underwent an endoscopic procedure for suspected bile leak after hepatobiliary surgery; the presence of bile leak on endoscopic retrograde cholangiopancreatography (ERCP) was evaluated retrospectively. Two groups were created based on bile leak severity at ERCP. We defined success as follows: technical, successful placement of the plastic stent at the intended bile duct; clinical, improvement in symptoms of bile leak; and eventual, disappearance of bile leak at ERCP. We evaluated several factors that influenced the success of the endoscopic procedure and the differences between bile leak severity. Success rates were as follows: technical, 90%; clinical, 79%; and eventual, 71%. Median interval between first endoscopic procedure and achievement of eventual success was 135 days (IQR, 86-257 days). Bile leak severity was the only independent factor associated with eventual success (P = 0.01). Endoscopic therapy is safe and effective for postoperative bile leak. Bile leak severity is the most important factor influencing successful endoscopic therapy. © 2016 Japan Gastroenterological Endoscopy Society.
Analytical study of the performance of a geomembrane leak detection system.
Lugli, Francesco; Mahler, Claudio Fernando
2016-05-01
The electrical detection of leaks in geomembranes is a method that allows identifying leakage of contaminants in lined facilities (e.g. sanitary landfills, pollutant ponds, etc.). The procedure in the field involves placing electrodes above and below the geomembrane, to generate an electrical current, which in turn engenders an electric potential distribution in the protective layer (generally a clayey soil). The electric potential will be greater in areas with higher current density, i.e. near leaks. In this study, we combined models from the literature to carry out a parametric analysis to identify the variables that most influence the amplitude of the electrical signals produced by leaks. The basic hypothesis is that the electrical conduction phenomena in a liner system could be depicted by a direct current circuit. After determining the value of the current at the leak, we calculated the electric potential distribution according to the model of Darilek and Laine. This enabled analysing the sensitivity of the parameters, which can be useful in the design of landfills and facilitate the location of leaks. This study showed that geomembranes with low electrical resistance (owing to low thickness, low resistivity, or extensive area) can hinder the leak detection process. In contrast, low thickness and high resistivity of the protection layer magnify the leak signal. © The Author(s) 2016.
Cao, Guo qiang; Kang, Jun; Wang, Fangwen; Wang, Hucheng
2012-05-01
We evaluated the safety and efficacy of increasing doses of autologous blood patch pleurodesis in treating persistent air leaks in patients with advanced chronic obstructive pulmonary disease (COPD). Forty-four patients with COPD and spontaneous pneumothorax (SP) on the 7th day after intercostal tube drainage were randomly assigned to 4 groups, with 11 patients in each group. Groups A, B, and C were given increasing doses of autologous blood--ie, 0.5 mL/kg, 1 mL/kg, 2 mL/kg, respectively--whereas group D was given 1 mL/kg normal saline only. The procedure was repeated if the air leak persisted on postoperative days 9 and 11. Patients in group D crossed over and received autologous blood as in group B if the air leak was still present on the 13th postoperative day. No patient died in the study. The air leak was sealed by the 13th postoperative day only in patients with air leaks smaller than size 3. Air leaks were classified as 0 to 3 [12], ie, size 0=no air leak; size 1=air leak on vigorous coughing only; size 2=small continuous air leak on gentle respiration; and size 3=large continuous air leak on gentle respiration. The success rates by the 13th postoperative day in groups A, B, C, and D were 27%, 82%, 82%, and 9%, respectively. The success rate (82%) was significantly higher in groups B and C than in group A (p=0.003) and D (p>0.01). Using autologous blood to treat secondary spontaneous pneumothorax (SSP) in patients with advanced COPD is easy, safe, and effective. The dose of blood required for autologous blood patch pleurodesis should be dependent on the body weight, and 1 mL/kg blood may be efficient. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, James D.; Mobbs, Stephen D.; Wellpott, Axel; Allen, Grant; Bauguitte, Stephane J.-B.; Burton, Ralph R.; Camilli, Richard; Coe, Hugh; Fisher, Rebecca E.; France, James L.; Gallagher, Martin; Hopkins, James R.; Lanoiselle, Mathias; Lewis, Alastair C.; Lowry, David; Nisbet, Euan G.; Purvis, Ruth M.; O'Shea, Sebastian; Pyle, John A.; Ryerson, Thomas B.
2018-03-01
An uncontrolled gas leak from 25 March to 16 May 2012 led to evacuation of the Total Elgin wellhead and neighbouring drilling and production platforms in the UK North Sea. Initially the atmospheric flow rate of leaking gas and condensate was very poorly known, hampering environmental assessment and well control efforts. Six flights by the UK FAAM chemically instrumented BAe-146 research aircraft were used to quantify the flow rate. The flow rate was calculated by assuming the plume may be modelled by a Gaussian distribution with two different solution methods: Gaussian fitting in the vertical and fitting with a fully mixed layer. When both solution methods were used they compared within 6 % of each other, which was within combined errors. Data from the first flight on 30 March 2012 showed the flow rate to be 1.3 ± 0.2 kg CH4 s-1, decreasing to less than half that by the second flight on 17 April 2012. δ13CCH4 in the gas was found to be -43 ‰, implying that the gas source was unlikely to be from the main high pressure, high temperature Elgin gas field at 5.5 km depth, but more probably from the overlying Hod Formation at 4.2 km depth. This was deemed to be smaller and more manageable than the high pressure Elgin field and hence the response strategy was considerably simpler. The first flight was conducted within 5 days of the blowout and allowed a flow rate estimate within 48 h of sampling, with δ13CCH4 characterization soon thereafter, demonstrating the potential for a rapid-response capability that is widely applicable to future atmospheric emissions of environmental concern. Knowledge of the Elgin flow rate helped inform subsequent decision making. This study shows that leak assessment using appropriately designed airborne plume sampling strategies is well suited for circumstances where direct access is difficult or potentially dangerous. Measurements such as this also permit unbiased regulatory assessment of potential impact, independent of the emitting party, on timescales that can inform industry decision makers and assist rapid-response planning by government.
Leak detectability of the Norman Wells pipeline by mass balance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liou, J.C.P.
Pipeline leak detection using software-based systems is becoming common practice. The detectability of such systems is measured by how small and how quickly a leak can be detected. Algorithms used and measurement uncertainties determine leak detectability. This paper addresses leak detectability using mass balance, establishes leak detectability for Norman Wells pipelines, and compares it with field leak test results. The pipeline is operated by the Interprovincial Pipe Line (IPL) Inc., of Edmonton, Canada. It is a 12.75-inch outside diameter steel pipe with variable wall thickness. The length of the pipe is approximately 550 miles (868.9 km). The pipeline transports lightmore » crude oil at a constant flow rate of about 250 m{sup 3}/hr. The crude oil can enter the pipeline at two locations. Besides the Norman Wells inlet, there is a side line near Zama terminal that can inject crude oil into the pipeline.« less
Measuring Pinhole Leaks - A Novel Method
NASA Technical Reports Server (NTRS)
Dunn, Carol Anne
2009-01-01
Both of the shuttle pads have one of these large liquid hydrogen tanks and the Shuttle program is currently using both pads. However, just recently, there has been increasing concerns over possible air leaks from the outside into the evacuated region. A method to detect leaks involving measuring the change in the boil-off rate of the liquid hydrogen in the tank.
Low anastomotic leak rate after colorectal surgery: a single-centre study.
Jones, O M; John, S K P; Horseman, N; Lawrance, R J; Fozard, J B J
2007-10-01
Anastomotic leak after colorectal surgery is a serious event associated with significant morbidity and mortality. There is little consensus regarding 'acceptable' rates of leakage, however. This study describes the experience of anastomotic leakage after both elective and emergency colorectal surgery in a district general hospital. A prospectively collected database of all patients with a diagnosis of colorectal cancer in a single hospital formed the basis of the study. Leak was defined as breakdown of the anastomosis contributing to death or requiring reoperation or reintervention. A total of 949 patients underwent surgery with an anastomosis between 1996 and 2004, including 331 patients treated with anterior resection. Anastomotic leaks requiring reoperation occurred in eight patients (0.8%). Thirty-day and in-hospital mortality was 4%. A very low rate of anastomotic leakage after colorectal surgery is possible in a district general hospital setting. Given the impact of anastomotic leakage on function, tumour recurrence and long-term survival, it should be considered as a marker of surgical quality when evaluating surgical performance.
Measurements of True Leak Rates of MEMS Packages
Han, Bongtae
2012-01-01
Gas transport mechanisms that characterize the hermetic behavior of MEMS packages are fundamentally different depending upon which sealing materials are used in the packages. In metallic seals, gas transport occurs through a few nanoscale leak channels (gas conduction) that are produced randomly during the solder reflow process, while gas transport in polymeric seals occurs through the bulk material (gas diffusion). In this review article, the techniques to measure true leak rates of MEMS packages with the two sealing materials are described and discussed: a Helium mass spectrometer based technique for metallic sealing and a gas diffusion based model for polymeric sealing. PMID:22736994
The Redax® Coaxial Drain in pulmonary lobectomy: a study of efficacy
Parini, Sara; Papalia, Esther; Massera, Fabio; Turello, Davide; Baietto, Guido; Casadio, Caterina
2017-01-01
Background Pleural drainage is required after pulmonary lobectomy to evacuate air-leak and fluid. We compared the performance of the new Redax® Coaxial Drain (CD) (Redax, Mirandola, Italy) with a standard chest tube (CT) in terms of fluid and air-leak evacuation. Methods Fifty-two patients receiving a 24-F CD under water-seal after pulmonary lobectomy through open surgery or video-assisted thoracic surgery (VATS) were matched according to demographic, clinical and pathological variables with 104 patients receiving a 24-F CT. Fluid evacuation and post-operative day 0 (POD0) fluid evacuation rate, air-leak rate, tension pneumothorax or increasing subcutaneous emphysema, tube occlusion at removal, visual analog scale (VAS) score at rest and during cough, chest drain duration, pleural fluid accumulation or residual pleural cavity after tube removal, post-operative morbidity and mortality rate were recorded and compared between the two groups. Results No differences were recorded in post-operative morbidity and mortality rates. Fluid drainage rates on POD0 were significantly higher in CD group (73% vs. 48%; P=0.004); air-leak occurrence was similar in both groups and no differences were recorded in terms of tension pneumothorax or increasing subcutaneous emphysema rates; VAS score was lower for CD when compared with CT and it reached significant difference in the subgroups of patients operated on by VATS; no cases of occlusion at removal were recorded in CD patient. Conclusions Redax® CD is safe and efficient in air-leak and fluid evacuation; due to its design and constituting material it is superior to standard CTs in terms of fluid evacuation rate and patient post-operative comfort. PMID:29221298
Local Leak Detection and Health Monitoring of Pressurized Tanks
NASA Technical Reports Server (NTRS)
Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam
2011-01-01
An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.
NASA Technical Reports Server (NTRS)
Rodriguez, P. I.; Markovitch, R.
1992-01-01
This report is intended to reveal the apparent relationship of air seal leakage rates between 2 atmospheres (atm) to 1 atm and 1 atm to vacuum conditions. Gas dynamics analysis is provided as well as data summarizing the MSFC test report, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study With Delta Pressure Leak Rate Comparison Test Report'.
Anderloni, Andrea; Genco, Chiara; Massidda, Marco; Di Leo, Milena; Fumagalli, Uberto Romario; Rosati, Riccardo; Correale, Loredana; Maselli, Roberta; Ferrara, Elisa Chiara; Jovani, Manol; Repici, Alessandro
2018-06-05
The study aimed to evaluate the effectiveness and safety of self-expanding metal stents (SEMS) in the management of post-surgical esophageal leaks. Retrospective data of consecutive patients with a post-surgical esophageal leak treated by means of a metal stent between January 2008 and December 2014 at the Humanitas Research Hospital (Milan, Italy) were extracted from a prospectively maintained register of SEMS used for benign indications, such as post-surgical benign esophageal strictures and/or leaks. The primary outcome of the study was to assess the rate of successful leak closure and to identify the variables associated with its achievement. As a secondary outcome, we evaluated the overall safety of SEMS placement and the efficacy and safety for different types of SEMS in this specific setting of patients. Leak resolution was documented with endoscopic and/or imaging studies. In the case of leak persistence, further attempts of esophageal stenting were carried out at the discretion of both endoscopists and surgeons. A total of 49 patients were included in the study (men 41 of 49, 83.7%, mean age 62.4 ± 11.9). One patient was excluded from analysis, because of death 1 day after stent insertion due to worsening of pre-existing mediastinitis. A total number of 82 stents were placed (mean number of stents per patient: 1.7) in 49 patients: 35 patients (71.4%) received a partially covered SEMS (PCSEMS) as the first stent positioned, while the remaining 14 (28.6%) received a fully covered SEMS (FCSEMS); but 1 patient (2%) died following stent insertion; therefore, data regarding therapeutic success were available for 48 patients. Stents were left in place for a mean period of 21.9 ± 15.2 days. Leak closure after the first stent placement was achieved in 22 of 48 (45.8%) patients. Of the 26 patients with failure of index stent placement, 18 patients underwent further stenting attempts (69.2%), and secondary closure of leak was achieved in 7 (38.9%) of these 18 patients. Thus, the overall success rate was 60.5% (29 of 48). On the basis of stent type, the success rate was 57.1% (8 of 14) for FCSEMS and 64.7% (22 of 34) for PCSEMS. Logistic regression analysis did not find any significant association between successful leak closure and analyzed variables. Overall mortality was 13.0%. Complication rate was 38.8% (19 of 49 patients). The use of SEMS is an effective and safe option for post-surgical esophageal leaks, with no evidence of any significant influence of stent type on outcome. © 2018 S. Karger AG, Basel.
Leak rate of seals: Effective-medium theory and comparison with experiment.
Lorenz, B; Persson, B N J
2010-02-01
Seals are extremely useful devices to prevent fluid leakage. We present an effective-medium theory of the leak rate of rubber seals, which is based on a recently developed contact mechanics theory. We compare the theory with experimental results for seals consisting of silicon rubber in contact with sandpaper and sand-blasted PMMA surfaces.
Emissions due to the natural gas storage well-casing blowout at Aliso Canyon/SS-25
NASA Astrophysics Data System (ADS)
Herndon, Scott; Daube, Conner; Jervis, Dylan; Yacovitch, Tara; Roscioli, Joseph; Curry, Jason; Nelson, David; Knighton, Berk
2017-04-01
The pronounced increase in unconventional gas production in North America over the last fifteen years has intensified interest in understanding emissions and leaks in the supply chain from well pad to end use. Los Angeles, California is home 19 million consumers of natural gas in both industry and domestic end use. The well blowout at Aliso Canyon Natural Gas Storage Facility in the greater Los Angeles area was quantified using the tracer flux ratio method (TFR). Over 400 tracer plume transects were collected, each lasting 15-300 seconds, using instrumentation aboard a mobile platform on 25 days between December 21, 2015 and March 9, 2016. The leak rate from October 23rd to February 11th has been estimated here using a combination of this work (TFR) and the flight mass balance (FMB) data [Conley et al., 2016]. This estimate relies on the TFR data as the most specific SS-25 emission dataset. Scaling the FMB dataset, the leak rate is projected from Oct 23rd to December 21th. Adding up the emissions inferred and measured suggests a total leak burden of 86,022 ± 8,393 metric tons of methane. This work quantified the emissions during the "bottom kill" procedure which halted the primary emission leak. The ethane to methane enhancement ratio observed downwind of the leak site is consistent with the content of ethane in the natural gas at this site and provides definitive evidence that the methane emission rate quantified via tracer flux ratio is not due to a nearby landfill or other potential biogenic sources. Additionally, the TFR approach employed here is assessing only the leaks due to the SS-25 well blowout and excludes other possible emissions at the facility.
Ahmed, Omar H; Marcus, Sonya; Tauber, Jenna R; Wang, Binhuan; Fang, Yixin; Lebowitz, Richard A
2017-01-01
Objective Perioperative lumbar drain (LD) use in the setting of endoscopic cerebrospinal fluid (CSF) leak repair is a well-established practice. However, recent data suggest that LDs may not provide significant benefit and may thus confer unnecessary risk. To examine this, we conducted a meta-analysis to investigate the effect of LDs on postoperative CSF leak recurrence following endoscopic repair of CSF rhinorrhea. Data Sources A comprehensive search was performed with the following databases: Ovid MEDLINE (1947 to November 2015), EMBASE (1974 to November 2015), Cochrane Review, and PubMed (1990 to November 2015). Review Method A meta-analysis was performed according to PRISMA guidelines. Results A total of 1314 nonduplicate studies were identified in our search. Twelve articles comprising 508 cases met inclusion criteria. Overall, use of LDs was not associated with significantly lower postoperative CSF leak recurrence rates following endoscopic repair of CSF rhinorrhea (odds ratio: 0.89, 95% confidence interval: 0.40-1.95) as compared with cases performed without LDs. Subgroup analysis of only CSF leaks associated with anterior skull base resections (6 studies, 153 cases) also demonstrated that lumbar drainage did not significantly affect rates of successful repair (odds ratio: 2.67, 95% confidence interval: 0.64-11.10). Conclusions There is insufficient evidence to support that adjunctive lumbar drainage significantly reduces postoperative CSF leak recurrence in patients undergoing endoscopic CSF leak repair. Subgroup analysis examining only those patients whose CSF leaks were associated with anterior skull base resections demonstrated similar results. More level 1 and 2 studies are needed to further investigate the efficacy of LDs, particularly in the setting of patients at high risk for CSF leak recurrence.
Cohen, Salomon; Jones, Samuel H; Dhandapani, Sivashanmugam; Negm, Hazem M; Anand, Vijay K; Schwartz, Theodore H
2018-01-01
Postoperative cerebrospinal fluid (CSF) leak is a persistent, albeit much less prominent, complication following endonasal endoscopic surgery. The pathology with highest risk is suprasellar meningiomas. A postoperative lumbar drain (LD) is used to decrease the risk of CSF leak but is not universally accepted. To compare the rates of postoperative CSF leak between patients with and without LD who underwent endonasal endoscopic surgical resection of suprasellar meningiomas. A consecutive series of newly diagnosed suprasellar meningiomas was drawn from a prospectively acquired database of endonasal endoscopic surgeries at our institution. An intraoperative, preresection LD was placed and left open at 5 cc/h for ∼48 h. In a subset of patients, the LD could not be placed. Rates of postoperative CSF leak were compared between patients with and without an LD. Twenty-five patients underwent endonasal endoscopic surgical resection of suprasellar meningiomas. An LD could not be placed in 2 patients. There were 2 postoperative CSF leaks (8%), both of which occurred in the patients who did not have an LD (P = .0033). The average body mass index (BMI) of the patients in whom the LD could not be placed was 39.1 kg/m2, compared with 27.6 kg/m2 for those in whom the LD could be placed (P = .009). In the subgroup of obese patients (BMI > 30 kg/m2), LD placement was protective against postoperative CSF leak (P = .022). The inability to place an LD in patients with obesity is a risk factor for postoperative CSF leak. An LD may be useful to prevent postoperative CSF leak, particularly in patients with elevated BMI. Copyright © 2017 by the Congress of Neurological Surgeons
Rock deformation models and fluid leak-off in hydraulic fracturing
NASA Astrophysics Data System (ADS)
Yarushina, Viktoriya M.; Bercovici, David; Oristaglio, Michael L.
2013-09-01
Fluid loss into reservoir rocks during hydraulic fracturing is modelled via a poro-elastoplastic pressure diffusion equation in which the total compressibility is a sum of fluid, rock and pore space compressibilities. Inclusion of pore compressibility and porosity-dependent permeability in the model leads to a strong pressure dependence of leak-off (i.e. drainage rate). Dilation of the matrix due to fluid invasion causes higher rates of fluid leak-off. The present model is appropriate for naturally fractured and tight gas reservoirs as well as for soft and poorly consolidated formations whose mechanical behaviour departs from simple elastic laws. Enhancement of the leak-off coefficient by dilation, predicted by the new model, may help explain the low percentage recovery of fracturing fluid (usually between 5 and 50 per cent) in shale gas stimulation by hydraulic fracturing.
Recent evaluations of crack-opening-area in circumferentially cracked pipes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, S.; Brust, F.; Ghadiali, N.
1997-04-01
Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. The leak rates depend on the crack-opening area of the through-wall crack in the pipe. In addition to LBB analyses which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessingmore » temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section XI. The objectives of this study were to review, evaluate, and refine current predictive models for performing crack-opening-area analyses of circumferentially cracked pipes. The results from twenty-five full-scale pipe fracture experiments, conducted in the Degraded Piping Program, the International Piping Integrity Research Group Program, and the Short Cracks in Piping and Piping Welds Program, were used to verify the analytical models. Standard statistical analyses were performed to assess used to verify the analytical models. Standard statistical analyses were performed to assess quantitatively the accuracy of the predictive models. The evaluation also involved finite element analyses for determining the crack-opening profile often needed to perform leak-rate calculations.« less
Reusable rocket engine optical condition monitoring
NASA Technical Reports Server (NTRS)
Wyett, L.; Maram, J.; Barkhoudarian, S.; Reinert, J.
1987-01-01
Plume emission spectrometry and optical leak detection are described as two new applications of optical techniques to reusable rocket engine condition monitoring. Plume spectrometry has been used with laboratory flames and reusable rocket engines to characterize both the nominal combustion spectra and anomalous spectra of contaminants burning in these plumes. Holographic interferometry has been used to identify leaks and quantify leak rates from reusable rocket engine joints and welds.
Mitochondrial proton and electron leaks.
Jastroch, Martin; Divakaruni, Ajit S; Mookerjee, Shona; Treberg, Jason R; Brand, Martin D
2010-01-01
Mitochondrial proton and electron leak have a major impact on mitochondrial coupling efficiency and production of reactive oxygen species. In the first part of this chapter, we address the molecular nature of the basal and inducible proton leak pathways, and their physiological importance. The basal leak is unregulated, and a major proportion can be attributed to mitochondrial anion carriers, whereas the proton leak through the lipid bilayer appears to be minor. The basal proton leak is cell-type specific and correlates with metabolic rate. The inducible leak through the ANT (adenine nucleotide translocase) and UCPs (uncoupling proteins) can be activated by fatty acids, superoxide or lipid peroxidation products. The physiological role of inducible leak through UCP1 in mammalian brown adipose tissue is heat production, whereas the roles of non-mammalian UCP1 and its paralogous proteins, in particular UCP2 and UCP3, are not yet resolved. The second part of the chapter focuses on the electron leak that occurs in the mitochondrial electron transport chain. Exit of electrons prior to the reduction of oxygen to water at cytochrome c oxidase causes superoxide production. As the mechanisms of electron leak are crucial to understanding their physiological relevance, we summarize the mechanisms and topology of electron leak from complexes I and III in studies using isolated mitochondria. We also highlight recent progress and challenges of assessing electron leak in the living cell. Finally, we emphasize the importance of proton and electron leak as therapeutic targets in body mass regulation and insulin secretion.
Moreno-Sánchez, R; Bravo, C; Westerhoff, H V
1999-09-01
Two complementary methods were used to determine how the rate of respiration and that of ATP hydrolysis were controlled in rat liver submitochondrial particles. In the first, 'direct control analysis' method, respiration was titrated with malonate, antimycin or cyanide at 20, 30 and 37 degrees C, to determine the flux control exerted by succinate dehydrogenase, cytochrome bc1 complex and cytochrome c oxidase, respectively. Together, the three respiratory complexes only controlled the flux by about 50%, leaving the other 50% of flux control to the H+ leak. In the second, 'elasticity based' method, the elasticity coefficients of the respiratory chain or the H+-ATPase and the H+ leak towards the H+ gradient were determined. Then, the flux control coefficients were calculated using the connectivity and summation laws of metabolic control theory. The correspondence between the flux control coefficients determined in the two ways validated the two methods. This allowed us to use the second method to analyse what was the kinetic origin of the observed distribution of control. Control of ATP hydrolysis by the ATPase decreased with increasing ATPase activity; hence, the control exerted by the H+ leak increased with increasing ATPase activity, due to a diminishing elasticity towards the H+ gradient. Reverse electron transport was mainly controlled by the ATPase; the sum of flux control coefficients of succinate dehydrogenase, NADH-CoQ oxidoreductase, and H+-ATPase yielded a value greater than one, indicating that the H+ leak exerted a significant negative control on this pathway.
Assessment of Component-level Emission Measurements ...
Oil and natural gas (ONG) production facilities have the potential to emit a substantial amount of greenhouse gasses, hydrocarbons and hazardous air pollutants into the atmosphere. These emissions come from a wide variety of sources including engine exhaust, combustor gases, atmospheric venting from uncontrolled tanks and leaks. Engine exhaust, combustor gases and atmospheric tank venting are included in the initial estimation of a production facilities cumulative emissions. However, there is a large amount of uncertainty associated with magnitude and composition of leaks at these facilities. In order to understand the environmental impacts of these emissions we must first be able characterize the emission flow rate and chemical composition of these leaks/venting. A number of recent publications regarding emission flow rate measurements of components at ONG production facilities have brought into question the validity of such measurements and the sampling methodology. An accurate methodology for quantifying hydrocarbon leaks/venting is needed to support both emission inventories and environmental compliance. This interim report will summarize recent results from a small leak survey completed at ONG production facilities in Utah to characterize their flow rate and chemical composition using a suite of instruments using a high volume sampler (Bacharach Hi Flow Sampler; Bacharach, Inc.), as well as infrared (IR) cameras, a photoionization detector (PID), a fl
The Impact of Operative Approach on Postoperative Complications Following Colectomy for Colon Caner.
Mungo, Benedetto; Papageorge, Christina M; Stem, Miloslawa; Molena, Daniela; Lidor, Anne O
2017-08-01
Colectomy is one of the most common major abdominal procedures performed in the USA. A better understanding of risk factors and the effect of operative approach on adverse postoperative outcomes may significantly improve quality of care. Adult patients with a primary diagnosis of colon cancer undergoing colectomy were selected from the National Surgical Quality Improvement Program 2013-2015 targeted colectomy database. Patients were stratified into five groups based on specific operative approach. Univariate and multivariate analyses were used to compare the five groups and identify risk factors for 30-day anastomotic leak, readmission, and mortality. In total, 25,097 patients were included in the study, with a 3.32% anastomotic leak rate, 1.20% mortality rate, and 9.57% readmission rate. After adjusting for other factors, open surgery and conversion to open significantly increased the odds for leak, mortality, and readmission compared to laparoscopy. Additionally, smoking and chemotherapy increased the risk for leak and readmission, while total resection was associated with increased mortality and leak. Operative approach and several other potentially modifiable perioperative factors have a significant impact on risk for adverse postoperative outcomes following colectomy. To improve quality of care for these patients, efforts should be made to identify and minimize the influence of such risk factors.
Presentation and surgical management of leaks after mini-gastric bypass for morbid obesity.
Genser, Laurent; Carandina, Sergio; Tabbara, Malek; Torcivia, Adriana; Soprani, Antoine; Siksik, Jean-Michel; Cady, Jean
2016-02-01
Few data exist about the characteristics and management of enteric leaks after mini-gastric bypass (MGB). We aimed to describe the incidence, presentation, and surgical management of enteric leaks in patients who underwent laparoscopic MGB for morbid obesity. Private practice. An 8-year, 9-month retrospective chart review was performed on patients who had enteric leak requiring reoperation after MGB at a single institution. Thirty-five of 2321 patients were included. Ninety-seven percent had symptoms. Arterial hypertension and heavy smoking were predicting factors of leaks occurrence post-MGB (P<.01). Enteric leak was diagnosed by systematic upper gastrointestinal series in 4 pts (11.4%) and by computed tomography with oral water soluble contrast in 4 of 31 pts (13%). In the other 27 patients, diagnosis of the leak was made intraoperatively. Eleven patients (32%) had leak arising from the gastric stapler line (type 1), 4 (11%) from the gastrojejunal anastomosis (type 2), and 20 (57%) from undetermined origin. The most common presentation was intra-abdominal abscess in type 1 and leaks of undetermined origin and generalized peritonitis in type 2. One third of the patients who underwent reoperation developed well-drained chronic fistula into the irrigation-drainage system, with complete healing in all patients without any further procedure. The mean hospital stay was 19 days with no mortality reported. Enteric leak leading to intra-abdominal sepsis post-MGB is rare (1.5%) An operative aggressive management based on clinical symptoms is the treatment of choice allowing no postoperative leak-related mortality and complete healing. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Lucke-Wold, Brandon; Mendez, Gustavo; Cua, David; Akins, Paul; Gillham, Haley; Ciporen, Jeremy
2018-01-01
High flow orbital apex or middle fossa cerebrospinal fluid (CSF) leaks can be life threatening and complex to repair. These leaks associated with large dural defects are most commonly repaired with an open temporalis muscle patch or free flaps, but these flaps do not always stop the leak. A 65-year-old patient presented two years after orbital exenteration and radiation for squamous cell carcinoma. He developed multi-organism meningitis and pneumocephalus secondary to a large high-flow orbital apex/middle fossa CSF leak. To repair the leak, a combined endoscopic transorbital/endonasal approach with pedicled nasospetal flap and dermis fat graft was used. We describe the unique endoscopic technique that was used to treat the life threatening high flow orbital apex/middle fossa CSF leak. The technique allowed the use of the transposed pedicled flap, which is an alternative to the free flap in controlling CSF leak. Cisternogram post-operatively and clinical exam confirmed resolution of CSF leak. Although a critically ill patient at admission with a modified Rankin scale (MRS) of 5, he was discharged home on continued IV antibiotic therapy with a MRS of 3. Endoscopic evaluation at three months after treatment showed the effectiveness of the flap and he continued to improve clinically. This is the first case to describe a combined endoscopic transorbital and endonasal repair of high flow orbital apex/middle fossa CSF leak with a pedicled nasoseptal flap. These techniques can be utilized during initial reconstruction after orbital exenteration or as a salvage flap.
Annular Air Leaks in a liquid hydrogen storage tank
NASA Astrophysics Data System (ADS)
Krenn, AG; Youngquist, RC; Starr, SO
2017-12-01
Large liquid hydrogen (LH2) storage tanks are vital infrastructure for NASA, the DOD, and industrial users. Over time, air may leak into the evacuated, perlite filled annular region of these tanks. Once inside, the extremely low temperatures will cause most of the air to freeze. If a significant mass of air is allowed to accumulate, severe damage can result from nominal draining operations. Collection of liquid air on the outer shell may chill it below its ductility range, resulting in fracture. Testing and analysis to quantify the thermal conductivity of perlite that has nitrogen frozen into its interstitial spaces and to determine the void fraction of frozen nitrogen within a perlite/frozen nitrogen mixture is presented. General equations to evaluate methods for removing frozen air, while avoiding fracture, are developed. A hypothetical leak is imposed on an existing tank geometry and a full analysis of that leak is detailed. This analysis includes a thermal model of the tank and a time-to-failure calculation. Approaches to safely remove the frozen air are analyzed, leading to the conclusion that the most feasible approach is to allow the frozen air to melt and to use a water stream to prevent the outer shell from chilling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Austin Douglas; Runnels, Joel T.; Moore, Murray E.
A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canistermore » integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.« less
NASA Astrophysics Data System (ADS)
Niroumand, Amir M.; Homayouni, Hooman; DeVaal, Jake; Golnaraghi, Farid; Kjeang, Erik
2016-08-01
This paper describes a diagnostic tool for in-situ characterization of the rate and distribution of hydrogen transfer leaks in Polymer Electrolyte Membrane (PEM) fuel cell stacks. The method is based on reducing the air flow rate from a high to low value at a fixed current, while maintaining an anode overpressure. At high air flow rates, the reduction in air flow results in lower oxygen concentration in the cathode and therefore reduction in cell voltages. Once the air flow rate in each cell reaches a low value at which the cell oxygen-starves, the voltage of the corresponding cell drops to zero. However, oxygen starvation results from two processes: 1) the electrochemical oxygen reduction reaction which produces current; and 2) the chemical reaction between oxygen and the crossed over hydrogen. In this work, a diagnostic technique has been developed that accounts for the effect of the electrochemical reaction on cell voltage to identify the hydrogen leak rate and number of leaky cells in a fuel cell stack. This technique is suitable for leak characterization during fuel cell operation, as it only requires stack air flow and voltage measurements, which are readily available in an operational fuel cell system.
Vehicle-based Methane Mapping Helps Find Natural Gas Leaks and Prioritize Leak Repairs
NASA Astrophysics Data System (ADS)
von Fischer, J. C.; Weller, Z.; Roscioli, J. R.; Lamb, B. K.; Ferrara, T.
2017-12-01
Recently, mobile methane sensing platforms have been developed to detect and locate natural gas (NG) leaks in urban distribution systems and to estimate their size. Although this technology has already been used in targeted deployment for prioritization of NG pipeline infrastructure repair and replacement, one open question regarding this technology is how effective the resulting data are for prioritizing infrastructure repair and replacement. To answer this question we explore the accuracy and precision of the natural gas leak location and emission estimates provided by methane sensors placed on Google Street View (GSV) vehicles. We find that the vast majority (75%) of methane emitting sources detected by these mobile platforms are NG leaks and that the location estimates are effective at identifying the general location of leaks. We also show that the emission rate estimates from mobile detection platforms are able to effectively rank NG leaks for prioritizing leak repair. Our findings establish that mobile sensing platforms are an efficient and effective tool for improving the safety and reducing the environmental impacts of low-pressure NG distribution systems by reducing atmospheric methane emissions.
Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method
NASA Astrophysics Data System (ADS)
Arai, Kenta; Yoshida, Hajime
2014-10-01
Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.
NASA Technical Reports Server (NTRS)
Ward, William Douglas (Inventor)
2014-01-01
The different advantageous embodiments provide for identifying gas leakage in a platform. A processor unit identifies a rate of the gas of the substance leaking from a container in a first compartment for a platform. The processor unit also identifies an amount of gas that has leaked from the container at a selected time based on the rate of the gas of the substance leaking from the container and a total time. The processor unit identifies an amount of the gas of the substance present in a number of compartments associated with the first compartment using the amount of gas leaked from the container in the first compartment and a pressure for each compartment in the number of compartments. The processor unit determines whether the amount of gas in at least one of the first compartment and the number of compartments is outside of a desired amount for the gas.
Sammour, T; Lewis, M; Thomas, M L; Lawrence, M J; Hunter, A; Moore, J W
2017-01-01
Anastomotic leak can be a devastating complication, and early prediction is difficult. The aim of this study is to prospectively validate a simple anastomotic leak risk calculator and compare its predictive value with the estimate of the primary operating surgeon. Consecutive patients undergoing elective or emergency colon cancer surgery with a primary anastomosis over a 1-year period were prospectively included. A recently published anastomotic leak risk nomogram was converted to an online calculator ( www.anastomoticleak.com ). The calculator-derived risk of anastomotic leak and the risk estimated by the primary operating surgeon were recorded at the completion of surgery. The primary outcome was anastomotic leak within 90 days as defined by previously published criteria. Area under receiver operating characteristic curve analysis (AUROC) was performed for both risk estimates. A total of 105 patients were screened for inclusion during the study period, of whom 83 met the inclusion criteria. The overall anastomotic leak rate was 9.6%. The anastomotic leak calculator was highly predictive of anastomotic leak (AUROC 0.84, P = 0.002), whereas the surgeon estimate was not predictive (AUROC 0.40, P = 0.243). A simple anastomotic leak risk calculator is significantly better at predicting anastomotic leak than the estimate of the primary surgeon. Further external validation on a larger data set is required.
Field Trial of an Aerosol-Based Enclosure Sealing Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, Curtis; Springer, David
2015-09-01
This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology.« less
Methane Leaks from Natural Gas Systems Follow Extreme Distributions.
Brandt, Adam R; Heath, Garvin A; Cooley, Daniel
2016-11-15
Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4 ) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ∼15 000 measurements from 18 prior studies, we show that all available natural gas leakage data sets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of the total leakage volume. While prior studies used log-normal model distributions, we show that log-normal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of data sets to increase sample size is not recommended due to apparent deviation between sampled populations. Understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.
Methane Leaks from Natural Gas Systems Follow Extreme Distributions
Brandt, Adam R.; Heath, Garvin A.; Cooley, Daniel
2016-10-14
Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ~15,000 measurements from 18 prior studies, we show that all available natural gas leakage datasets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of themore » total leakage volume. While prior studies used lognormal model distributions, we show that lognormal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of datasets to increase sample size is not recommended due to apparent deviation between sampled populations. Finally, understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.« less
Methane Leaks from Natural Gas Systems Follow Extreme Distributions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandt, Adam R.; Heath, Garvin A.; Cooley, Daniel
Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ~15,000 measurements from 18 prior studies, we show that all available natural gas leakage datasets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of themore » total leakage volume. While prior studies used lognormal model distributions, we show that lognormal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of datasets to increase sample size is not recommended due to apparent deviation between sampled populations. Finally, understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.« less
NASA Astrophysics Data System (ADS)
de Vries, Jaap
2017-05-01
Adequate fire protection of distilled spirits stored in oak barrels requires understanding the failure mode of these barrels, including quantifying the leak rate. In this study, the use of a custom-calibrated, long-wave microbolometer camera is demonstrated to seek new protection methods for rack-stored distilled spirits. Individual oak barrels ranging between 200 L and 500 L filled with 75%/25% ethanol/water were exposed to both propane gas fires and pure ethanol pool fires. The IR camera was used to see through the smoke and flames showing the location of the leaks. The increase in HRR due to the leaked content was measured using gas calorimetry of the combustion products. This study showed that barrels leaked at a rate of approximately 4-8 lpm, resulting in heat release rates ranging between 1.2 and 2.4 MW. These numbers are confirmed by the quantitative measurements of gaseous H2O and CO¬2 in the exhaust. Surface temperature of the exposed oak could reach temperatures up to 750ºC.
An improved PCA method with application to boiler leak detection.
Sun, Xi; Marquez, Horacio J; Chen, Tongwen; Riaz, Muhammad
2005-07-01
Principal component analysis (PCA) is a popular fault detection technique. It has been widely used in process industries, especially in the chemical industry. In industrial applications, achieving a sensitive system capable of detecting incipient faults, which maintains the false alarm rate to a minimum, is a crucial issue. Although a lot of research has been focused on these issues for PCA-based fault detection and diagnosis methods, sensitivity of the fault detection scheme versus false alarm rate continues to be an important issue. In this paper, an improved PCA method is proposed to address this problem. In this method, a new data preprocessing scheme and a new fault detection scheme designed for Hotelling's T2 as well as the squared prediction error are developed. A dynamic PCA model is also developed for boiler leak detection. This new method is applied to boiler water/steam leak detection with real data from Syncrude Canada's utility plant in Fort McMurray, Canada. Our results demonstrate that the proposed method can effectively reduce false alarm rate, provide effective and correct leak alarms, and give early warning to operators.
Advanced laparoscopic bariatric surgery Is safe in general surgery training.
Kuckelman, John; Bingham, Jason; Barron, Morgan; Lallemand, Michael; Martin, Matthew; Sohn, Vance
2017-05-01
Bariatric surgery makes up an increasing percentage of general surgery training. The safety of resident involvement in these complex cases has been questioned. We evaluated patient outcomes in resident performed laparoscopic bariatric procedures. Retrospective review of patients undergoing a laparoscopic bariatric procedure over seven years at a tertiary care single center. Procedures were primarily performed by a general surgery resident and proctored by an attending surgeon. Primary outcomes included operative volume, operative time and leak rate with perioperative outcomes evaluated as secondary outcomes. A total of 1649 bariatric procedures were evaluated. Operations included laparoscopic bypass (690) and laparoscopic sleeve gastrectomy (959). Average operating time was 136 min. Eighteen leaks (0.67%) were identified. Graduating residents performed an average of 89 laparoscopic bariatric cases during their training. There were no significant differences between resident levels with concern to operative time or leak rate (p 0.97 and p = 0.54). General surgery residents can safely perform laparoscopic bariatric surgery. When proctored by a staff surgeon, a resident's level of training does not significantly impact leak rate. Published by Elsevier Inc.
Sherbini, S; Tamasanis, D; Sykes, J; Porter, S W
1986-12-01
A program was developed to calculate the exposure rate resulting from airborne gases inside a reactor containment building. The calculations were performed at the location of a wall-mounted area radiation monitor. The program uses Monte Carlo techniques and accounts for both the direct and scattered components of the radiation field at the detector. The scattered component was found to contribute about 30% of the total exposure rate at 50 keV and dropped to about 7% at 2000 keV. The results of the calculations were normalized to unit activity per unit volume of air in the containment. This allows the exposure rate readings of the area monitor to be used to estimate the airborne activity in containment in the early phases of an accident. Such estimates, coupled with containment leak rates, provide a method to obtain a release rate for use in offsite dose projection calculations.
Leak Rate Test for a Fiber Beam Monitor Contained in a Vacuum for the Muon g-2 Experiment
NASA Astrophysics Data System (ADS)
O'Mara, Bridget; Lane, Noel; Gross, Eisen; Gray, Frederick; Muon g-2 Collaboration
2014-09-01
The muon g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment with a precision of 0.14 parts per million (ppm). The measurement will build on the Brookhaven-based E821 experiment, which yielded results suggesting new physics such as supersymmetry. The Fiber Beam Monitors (FBMs) are used in the experiment to determine the position and observe the motion of a muon beam and monitor the properties of the beam over time. The FBMs support a 9 cm × 8 cm ``harp'' with 7 scintillating fibers separated from each other by 13 mm, each with a diameter of 0.5 mm. The experiment requires a vacuum of less than 1 ×10-6 Torr to prevent trapping of electrons ionized from the residual gas by the electrostatic quadrupoles. To meet this requirement the FBMs must have a leak rate of less than 5 ×10-5 Torr L/s. We have constructed a vacuum system to simulate these conditions and have determined the leak rate of the FBMs within the constructed vacuum apparatus. This leak rate will be reported, along with preliminary results from tests of the light output from the scintillating fibers. The muon g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment with a precision of 0.14 parts per million (ppm). The measurement will build on the Brookhaven-based E821 experiment, which yielded results suggesting new physics such as supersymmetry. The Fiber Beam Monitors (FBMs) are used in the experiment to determine the position and observe the motion of a muon beam and monitor the properties of the beam over time. The FBMs support a 9 cm × 8 cm ``harp'' with 7 scintillating fibers separated from each other by 13 mm, each with a diameter of 0.5 mm. The experiment requires a vacuum of less than 1 ×10-6 Torr to prevent trapping of electrons ionized from the residual gas by the electrostatic quadrupoles. To meet this requirement the FBMs must have a leak rate of less than 5 ×10-5 Torr L/s. We have constructed a vacuum system to simulate these conditions and have determined the leak rate of the FBMs within the constructed vacuum apparatus. This leak rate will be reported, along with preliminary results from tests of the light output from the scintillating fibers. This material is based upon work supported by the National Science Foundation under Grant No. PHY-1206039.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anselmetti, Giovanni Carlo, E-mail: giovanni.anselmetti@ircc.i; Zoarski, Gregg; Manca, Antonio
The aim of this study was to assess the feasibility of and venous leakage reduction in percutaneous vertebroplasty (PV) using a new high-viscosity bone cement (PMMA). PV has been used effectively for pain relief in osteoporotic and malignant vertebral fractures. Cement extrusion is a common problem and can lead to complications. Sixty patients (52 female; mean age, 72.2 {+-} 7.2) suffering from osteoporosis (46), malignancy (12), and angiomas (2), divided into two groups (A and B), underwent PV on 190 vertebrae (86 dorsal, 104 lumbar). In Group A, PV with high-viscosity PMMA (Confidence, Disc-O-Tech, Israel) was used. This PMMA wasmore » injected by a proprietary delivery system, a hydraulic saline-filled screw injector. In Group B, a standard low-viscosity PMMA was used. Postprocedural CT was carried out to detect PMMA leakages and complications. Fisher's exact test and Wilcoxon rank test were used to assess significant differences (p < 0.05) in leakages and to evaluate the clinical outcome. PV was feasible, achieving good clinical outcome (p < 0.0001) without major complications. In Group A, postprocedural CT showed an asymptomatic leak in the venous structures of 8 of 98 (8.2%) treated vertebrae; a discoidal leak occurred in 6 of 98 (6.1%). In Group B, a venous leak was seen in 38 of 92 (41.3%) and a discoidal leak in 12 of 92 (13.0%). Reduction of venous leak obtained by high-viscosity PMMA was highly significant (p < 0.0001), whereas this result was not significant (p = 0.14) related to the disc. The high-viscosity PMMA system is safe and effective for clinical use, allowing a significant reduction of extravasation rate and, thus, leakage-related complications.« less
Sun, Da-Xin; Tan, Xiao-Dong; Gao, Feng; Xu, Jin; Cui, Dong-Xu; Dai, Xian-Wei
2015-01-01
Postoperative bile leak is a major surgical morbidity after curative resection with hepaticojejunostomy for hilar cholangiocarcinoma, especially in Bismuth-Corlette types III and IV. This retrospective study assessed the effectiveness and safety of an autologous hepatic round ligament flap (AHRLF) for reducing bile leak after hilar hepaticojejunostomy. Nine type III and IV hilar cholangiocarcinoma patients were consecutively hospitalized for elective perihilar partial hepatectomy with hilar hepaticojejunostomy using an AHRLF between October 2009 and September 2013. The AHRLF was harvested to reinforce the perihilar hepaticojejunostomy. Main outcome measures included operative time, blood loss, postoperative recovery times, morbidity, bile leak, R0 resection rate, and overall survival. All patients underwent uneventful R0 resection with hilar hepaticojejunostomy. No patient experienced postoperative bile leak. The AHRLF was associated with lack of bile leak after curative perihilar hepatectomy with hepaticojejunostomy for hilar cholangiocarcinoma, without compromising oncologic safety, and is recommended in selected patients.
Methane Gas Emissions - is Older Infrastructure Leakier?
NASA Astrophysics Data System (ADS)
Wendt, L. P.; Caulton, D.; Zondlo, M. A.; Lane, H.; Lu, J.; Golston, L.; Pan, D.
2015-12-01
Large gains in natural gas production from hydraulic fracturing is reinvigorating the US energy economy. It is a clean burning fuel with lower emissions than that of coal or oil. Studies show that methane (CH4) leaks from natural gas infrastructure vary widely. A broader question is whether leak rates of methane might offset the benefits of combustion of natural gas. Excess methane (CH4) is a major greenhouse gas with a radiative forcing constant of 25 times that of CO2 when projected over a 100-year period. An extensive field study of 250 wells in the Marcellus Shale conducted in July 2015 examined the emission rates of this region and identifed super-emitters. Spud production data will provide information as to whether older infrastructure is responsible for more of the emissions. Quantifying the emission rate was determined by extrapolating methane releases at a distance from private well pads using an inverse Gaussian plume model. Wells studied were selected by prevailing winds, distance from public roads, and topographical information using commercial (ARCGIS and Google Earth), non-profit (drillinginfo), and government (State of PA) databases. Data were collected from the mobile sensing lab (CH4, CO2 and H2O sensors), as well as from a stationary tower. Emission rates from well pads will be compared to their original production (spud dates) to evaluate whether infrastructure age and total production correlates with the observed leak rates. Very preliminary results show no statistical correlation between well pad production rates and observed leak rates.
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.
2014-01-01
NASA is developing advanced space-rated elastomeric seals to support future space exploration missions to low Earth orbit, the Moon, near Earth asteroids, and other destinations. This includes seals for a new docking system and vehicle hatches. These seals must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air for extended missions. Seal compression loads must be below prescribed limits so as not to overload the mechanisms that compress them, and seal adhesion forces must be low to allow the sealed interface to be separated when required (e.g., during undocking or hatch opening). NASA Glenn Research Center has developed a number of unique test fixtures to measure the leak rates and compression and adhesion loads of candidate seal designs under simulated thermal, vacuum, and engagement conditions. Tests can be performed on fullscale seals with diameters on the order of 50 in., subscale seals that are about 12 in. in diameter, and smaller specimens such as O-rings. Test conditions include temperatures ranging from -238 to 662degF (-150 to 350degC), operational pressure gradients, and seal-on-seal or seal-on-flange mating configurations. Nominal and off-nominal conditions (e.g., incomplete seal compression) can also be simulated. This paper describes the main design features and capabilities of each type of test apparatus and provides an overview of advanced seal development activities at NASA Glenn.
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H.
2014-01-01
NASA is developing advanced space-rated elastomeric seals to support future space exploration missions to low Earth orbit, the Moon, near Earth asteroids, and other destinations. This includes seals for a new docking system and vehicle hatches. These seals must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air for extended missions. Seal compression loads must be below prescribed limits so as not to overload the mechanisms that compress them, and seal adhesion forces must be low to allow the sealed interface to be separated when required (e.g., during undocking or hatch opening). NASA Glenn Research Center has developed a number of unique test fixtures to measure the leak rates and compression and adhesion loads of candidate seal designs under simulated thermal, vacuum, and engagement conditions. Tests can be performed on full-scale seals with diameters on the order of 50 in., subscale seals that are about 12 in. in diameter, and smaller specimens such as O-rings. Test conditions include temperatures ranging from -238 to 662 F (-150 to 350 C), operational pressure gradients, and seal-on-seal or seal-on-flange mating configurations. Nominal and off-nominal conditions (e.g., incomplete seal compression) can also be simulated. This paper describes the main design features and capabilities of each type of test apparatus and provides an overview of advanced seal development activities at NASA Glenn.
REFRIGERANT CONCENTRATIONS IN MOTOR VEHICLE PASSENGER COMPARTMENTS
Refrigerant leak rates were measured for faulty air-conditioner evaporators removed from vehicles, and results indicated a range of very small to very large leaks. A survey of automotive air-conditioning service shops was conducted, and leakage scenarios were evaluated to determi...
Technical factors associated with anastomotic leak after Roux-en-Y gastric bypass.
Smith, Mark D; Adeniji, Abidemi; Wahed, Abdus S; Patterson, Emma; Chapman, William; Courcoulas, Anita P; Dakin, Gregory; Flum, David; McCloskey, Carol; Mitchell, James E; Pomp, Alfons; Staten, Myrlene; Wolfe, Bruce
2015-01-01
Anastomotic leak is one of the most serious complications after Roux-en-Y gastric bypass (RYGB). Our objective was to examine the relationship between technical factors and incidence of clinically relevant anastomotic leak after RYGB in longitudinal assessment of bariatric surgery (LABS). The setting of the study was 11 bariatric centers in the United States, university, and private practice. Patient characteristics, technical factors of surgery, and postoperative outcomes were assessed by trained researchers using standardized protocols. Correlation of surgical factors of patients undergoing RYGB (n = 4444) with the incidence of postoperative anastomotic leak was assessed by univariate χ(2) analysis. Forty-four participants (1.0%, 95% CI .7%-1.3%) experienced a clinically relevant anastomotic leak. Of these, 39 (89%) underwent abdominal reoperation and 3 (7%) died. Technical factors associated with anastomotic leak were open surgery (P<.0001), revision surgery (P<.0001), and use of an abdominal drain (P = .02). Provocative leak testing, method of gastrojejunostomy, and use of fibrin sealant were not associated with anastomotic leak. Anastomotic leak after RYGB was rare (1.0%). Most cases required reintervention; however, the majority (93%) recovered from this event. Open surgery, revision surgery, and routine drain placement were associated with increased leak rate. Some of these findings may be due to differences in preoperative patient risk. Copyright © 2015 American Society for Metabolic and Bariatric Surgery. All rights reserved.
Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H
2016-03-01
The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.
Cerebrospinal fluid otorhinorrhea due to cochlear dysplasias.
Syal, Rajan; Tyagi, Isha; Goyal, Amit
2005-07-01
Cochlear dysplasia associated with defect in stapes footplate can be a cause of cerebrospinal fluid leak. Repair of cerebrospinal fluid leak in these cases is usually done by packing the vestibule with muscle or fascia. This traditional method of repair has 30-60% failure rate. Cerebrospinal fluid leak in four such patients was successfully repaired using multiple layer packing of vestibule, reinforced by pedicle temporalis muscle graft. Intraoperatively continuous lumbar drain was done. Magnetic resonance imaging of inner ear using 3D FSE T2WI and 3D FIESTA sequences was found helpful noninvasive investigation to localize site and route of cerebrospinal fluid leak.
Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak.
Dauber, I M; Pluss, W T; VanGrondelle, A; Trow, R S; Weil, J V
1985-08-01
Noninvasive techniques employing external counting of radiolabeled protein have the potential for measuring pulmonary vascular protein permeability, but their specificity and sensitivity remain unclear. We tested the specificity and sensitivity of a double-radioisotope method by injecting radiolabeled albumin (131I) and erythrocytes (99mTc) into anesthetized dogs and measuring the counts of each isotope for 150 min after injection with an external gamma probe fixed over the lung. We calculated the rate of increase of albumin counts measured by the probe (which reflects the rate at which protein leaks into the extravascular space). To assess permeability we normalized the rate of increase in albumin counts for changes in labeled erythrocyte signal to minimize influence of changes in vascular surface area and thus derived an albumin leak index. We measured the albumin leak index and gravimetric lung water during hydrostatic edema (acutely elevating left atrial pressure by left atrial balloon inflation: mean pulmonary arterial wedge pressure = 22.6 Torr) and in lung injury edema induced by high- (1.0 g/kg) and low-dose (0.25 g/kg) intravenous thiourea. To test specificity we compared hydrostatic and high-dose thiourea edema. The albumin leak index increased nearly fourfold from control after thiourea injury (27.2 +/- 2.3 X 10-4 vs. 7.6 +/- 0.9 X 10-4 min-1) but did not change from control levels after elevating left atrial pressure (8.9 +/- 1.2 X 10-4 min-1) despite comparable increases in gravimetric lung water. To test sensitivity we compared low-dose thiourea with controls. Following low-dose thiourea, the albumin leak index nearly doubled despite the absence of a measurable increase in lung water. We conclude that a noninvasive double radioisotope measurement of pulmonary vascular protein leak, employing external counting techniques and a simplified method of calculation, is specific for lung injury and is also sensitive enough to detect lung injury insufficient to produce detectable pulmonary edema.
An endoscopic mucosal grading system is predictive of leak in stapled rectal anastomoses.
Sujatha-Bhaskar, Sarath; Jafari, Mehraneh D; Hanna, Mark; Koh, Christina Y; Inaba, Colette S; Mills, Steven D; Carmichael, Joseph C; Nguyen, Ninh T; Stamos, Michael J; Pigazzi, Alessio
2018-04-01
Anastomotic leak is a devastating postoperative complication following rectal anastomoses associated with significant clinical and oncological implications. As a result, there is a need for novel intraoperative methods that will help predict anastomotic leak. From 2011 to 2014, patient undergoing rectal anastomoses by colorectal surgeons at our institution underwent prospective application of intraoperative flexible endoscopy with mucosal grading. Retrospective review of patient medical records was performed. After creation of the colorectal anastomosis, application of a three-tier endoscopic mucosal grading system occurred. Grade 1 was defined as circumferentially normal appearing peri-anastomotic mucosa. Grade 2 was defined as ischemia or congestion involving <30% of either the colon or rectal mucosa. Grade 3 was defined as ischemia or congestion involving >30% of the colon or rectal mucosa or ischemia/congestion involving both sides of the staple line. From 2011 to 2014, a total of 106 patients were reviewed. Grade 1 anastomoses were created in 92 (86.7%) patients and Grade 2 anastomoses were created in 10 (9.4%) patients. All 4 (3.8%) Grade 3 patients underwent immediate intraoperative anastomosis takedown and re-creation, with subsequent re-classification as Grade 1. Demographic and comorbidity data were similar between Grade 1 and Grade 2 patients. Anastomotic leak rate for the entire cohort was 12.2%. Grade 1 patients demonstrated a leak rate of 9.4% (9/96) and Grade 2 patients demonstrated a leak rate of 40% (4/10). Multivariate logistic regression associated Grade 2 classification with an increased risk of anastomotic leak (OR 4.09, 95% CI 1.21-13.63, P = 0.023). Endoscopic mucosal grading is a feasible intraoperative technique that has a role following creation of a rectal anastomosis. Identification of a Grade 2 or Grade 3 anastomosis should provoke strong consideration for immediate intraoperative revision.
Felbaum, Daniel R; Mueller, Kyle; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M
2016-12-28
Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk. A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboccipital craniectomy or craniotomy. Patient data was reviewed for craniotomy or craniectomy, dural graft, and/or sealant use as well as CSF complications. A pseudomeningocele was defined as a subcutaneous collection of cerebrospinal fluid palpable clinically and confirmed on imaging. A CSF leak was defined as a CSF-cutaneous fistula manifested by CSF leaking through the wound. All patients underwent regular postoperative visits of two weeks, one month, and three months. Our retrospective review identified 33 patients matching the inclusion criteria. Overall, our cohort had a 21% (7/33) rate of clinical and radiographic pseudomeningocele formation with 9% (3/33) requiring surgical revision or a separate procedure. The rate of clinical and radiographic pseudomeningocele formation in the myofascial cuff preservation technique was less than standard techniques (12% and 31%, respectively). Revision or further surgical procedures were also reduced in the myofascial cuff preservation technique vs. the standard technique (6% vs 13%). Preservation of the myofascial cuff during posterior fossa surgery is a simple and adoptable technique that reduces the rate of pseudomeningocele formation and CSF leak as compared with standard techniques.
Emergency membrane contactor based absorption system for ammonia leaks in water treatment plants.
Shao, Jiahui; Fang, Xuliang; He, Yiliang; Jin, Qiang
2008-01-01
Abstract Because of the suspected health risks of trihalomethanes (THMs), more and more water treatment plants have replaced traditional chlorine disinfection process with chloramines but often without the proper absorption system installed in the case of ammonia leaks in the storage room. A pilot plant membrane absorption system was developed and installed in a water treatment plant for this purpose. Experimentally determined contact angle, surface tension, and corrosion tests indicated that the sulfuric acid was the proper choice as the absorbent for leaking ammonia using polypropylene hollow fiber membrane contactor. Effects of several operating conditions on the mass transfer coefficient, ammonia absorption, and removal efficiency were examined, including the liquid concentration, liquid velocity, and feed gas concentration. Under the operation conditions investigated, the gas absorption efficiency over 99.9% was achieved. This indicated that the designed pilot plant membrane absorption system was effective to absorb the leaking ammonia in the model storage room. The removal rate of the ammonia in the model storage room was also experimentally and theoretically found to be primarily determined by the ammonia suction flow rate from the ammonia storage room to the membrane contactor. The ammonia removal rate of 99.9% was expected to be achieved within 1.3 h at the ammonia gas flow rate of 500 m3/h. The success of the pilot plant membrane absorption system developed in this study illustrated the potential of this technology for ammonia leaks in water treatment plant, also paved the way towards a larger scale application.
Circumferentially oversewn inverted stapled anastomosis.
Karam, Charbel; Lord, Sally; Gett, Rohan; Meagher, Alan P
2018-04-01
Leak rates of over 5% following anastomoses between the ileum and colon continue to be reported in large series and are associated with substantial morbidity and with mortality rates of 10-20%. In 1994, we began performing circumferentially oversewn inverted stapled anastomoses in patients undergoing ileo-colic anastomoses or ileostomy closure. It has become increasingly apparent that this method is associated with a low risk of leakage, which we should report. The anastomotic technique described was used in all patients undergoing ileo-colic anastomosis or closure of ileostomy by surgeon 1 (1994-2015) and in all ileo-colic anastomoses by surgeon 2 (2007-2015). All patients had a widely patent anastomosis constructed by two firings of a linear cutting stapler, as previously described. Additionally, the entire staple line was carefully oversewn with interrupted, inverting 4/0 polydioxanone sutures. Anastomotic leak was defined as a patient requiring re-operation or radiological drainage. One thousand and twelve patients underwent ileo-colic anastomosis and 685 patients underwent closure of ileostomy by surgeon 1, and 165 patients underwent ileo-colic anastomosis by surgeon 2. None of the 1862 patients required re-operation or radiological drainage for a leak (event rate 0%, 95% confidence interval 0-0.2%). However, there were three possible contained leaks treated successfully conservatively. The time taken to perform the actual anastomosis was measured in the last 30 ileo-colic resections. The median time was 42 min. While this method may well be too slow to gain widespread adoption, we hope this report encourages increased research into finding techniques with similar low leak rates. © 2016 Royal Australasian College of Surgeons.
Percutaneous management of postoperative bile leaks with an ethylene vinyl alcohol copolymer (Onyx).
Uller, W; Müller-Wille, R; Loss, M; Hammer, S; Schleder, S; Goessmann, H; Wiggermann, P; Stroszczynski, C; Wohlgemuth, W A
2013-12-01
The management of postoperative bile leakage is challenging especially if the leak rises from the cut surface of the liver and endoscopic treatment fails. Percutaneous transhepatic treatment of bile leaks with biliary drainage is accepted but often requires long-term placement of the drains and is associated with treatment failures. This series evaluates selective embolization of bile ducts with an ethylene vinyl alcohol copolymer (Onyx) in patients with postoperative bile leaks as an alternative treatment option. Between January and September 2012, five consecutive patients with persistent postoperative bile leaks underwent percutaneous transhepatic Onyx application and were analyzed regarding procedural management, complications and success rates. The persistent bile leaks were situated at the cystic stump (after cholecystectomy, n = 2), at the cut surface of the liver (after extended liver resection, n = 2) and at the surface of the liver after surgical exploration and perihepatic abscess (n = 1). Bile drainage alone (endoscopic or percutaneous) failed in all patients and open redo-surgery was deemed potentially harmful. Bilomas were externally drained in all patients before Onyx application. For the closure of bile leaks, Onyx was injected through a microcatheter in a previously built coil nest to keep Onyx in place. All bile leaks were initially closed immediately. In the 2nd week after Onyx embolization, 2 patients showed recurrent small bile leaks without clinical symptoms. In the 4th week after Onyx application, all leaks were closed. No complications occurred. All leaking bile ducts were initially closed immediately after Onyx application. In the 2nd week after Onyx application, 2 patients showed small bile leaks without clinical symptoms. All leaks were closed in the 4th week after Onyx application. © Georg Thieme Verlag KG Stuttgart · New York.
What is the optimal management of an intra-operative air leak in a colorectal anastomosis?
Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R
2018-02-01
An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
Clinical Factors and Postoperative Impact of Bile Leak After Liver Resection.
Martin, Allison N; Narayanan, Sowmya; Turrentine, Florence E; Bauer, Todd W; Adams, Reid B; Stukenborg, George J; Zaydfudim, Victor M
2018-04-01
Despite technical advances, bile leak remains a significant complication after hepatectomy. The current study uses a targeted multi-institutional dataset to characterize perioperative factors that are associated with bile leakage after hepatectomy to better understand the impact of bile leak on morbidity and mortality. Adult patients in the 2014-2015 ACS NSQIP targeted hepatectomy dataset were linked to the ACS NSQIP PUF dataset. Bivariable and multivariable regression analyses were used to assess the associations between clinical factors and post-hepatectomy bile leak. Of 6859 patients, 530 (7.7%) had a postoperative bile leak. Proportion of bile leaks was significantly greater in patients after major compared to minor hepatectomy (12.6 vs. 5.1%, p < 0.001). The proportion of patients with bile leak was significantly greater in patients after major hepatectomy who had concomitant enterohepatic reconstruction (31.8 vs. 10.1%, p < 0.001). Postoperative mortality was significantly greater in patients with bile leaks (6.0 vs. 1.7%, p < 0.001). After adjusting for significant covariates, bile leak was independently associated with increased risk of postoperative morbidity (OR = 4.55; 95% CI 3.72-5.56; p < 0.001). After adjusting for significant effects of postoperative complications, liver failure, and reoperation (all p<0.001), bile leak was not independently associated with increased risk of postoperative mortality (p = 0.262). Major hepatectomy and enterohepatic biliary reconstruction are associated with significantly greater rates of bile leak after liver resection. Bile leak is independently associated with significant postoperative morbidity. Mitigation of bile leak is critical in reducing morbidity and mortality after liver resection.
NASA Technical Reports Server (NTRS)
Russell, John M.
1994-01-01
In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.
NASA Astrophysics Data System (ADS)
Russell, John M.
1994-10-01
In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.
105-KE Isolation Barrier Leak Rate Acceptance Test Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCracken, K.J.
1995-06-14
This Acceptance Test Report (ATR) contains the completed and signed Acceptance Procedure (ATP) for the 105-KE Isolations Barrier Leak Rate Test. The Test Engineer`s log, the completed sections of the ATP in the Appendix for Repeat Testing (Appendix K), the approved WHC J-7s (Appendix H), the data logger files (Appendices T and U), and the post test calibration checks (Appendix V) are included.
40 CFR 270.4 - Effect of a permit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... regarding leak detection systems for new and replacement surface impoundment, waste pile, and landfill units, and lateral expansions of surface impoundment, waste pile, and landfill units. The leak detection system requirements include double liners, CQA programs, monitoring, action leakage rates, and response...
Nieto, Alejandra; Roehl, Holger; Brown, Helen; Adler, Michael; Chalus, Pascal; Mahler, Hanns-Christian
2016-01-01
Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against possible contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow (helium leakage testing). In order to correlate microbial CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificial leaks are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. However, the insertion of copper wires introduces leaks of unknown size and shape. With nonlinear finite element simulations, the aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force. The dependency of the aperture size on the copper wire diameter was quadratic. With the data obtained, we were able to calculate the leak size and model leak shape. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to hole size. Capping force also affected leak size. An increase in the capping force from 30 to 70 N resulted in a reduction of the aperture (leak size) by approximately 50% for all wire diameters. From 30 to 50 N, the reduction was approximately 33%. Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow. In order to correlate microbial ingress CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificially created defects (artificial leaks) are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. Up to date, the insertion of copper wires introduced leaks of unknown size and shape. With nonlinear finite element simulations, the effective aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force, and the leak shape was modelled. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to the hole size. © PDA, Inc. 2016.
NASA Astrophysics Data System (ADS)
Maheshwari, A.; Pathak, H. A.; Mehta, B. K.; Phull, G. S.; Laad, R.; Shaikh, M. S.; George, S.; Joshi, K.; Khan, Z.
2017-04-01
ITER Vacuum Vessel is a torus-shaped, double wall structure. The space between the double walls of the VV is filled with In-Wall Shielding Blocks (IWS) and Water. The main purpose of IWS is to provide neutron shielding during ITER plasma operation and to reduce ripple of Toroidal Magnetic Field (TF). Although In-Wall Shield Blocks (IWS) will be submerged in water in between the walls of the ITER Vacuum Vessel (VV), Outgassing Rate (OGR) of IWS materials plays a significant role in leak detection of Vacuum Vessel of ITER. Thermal Outgassing Rate of a material critically depends on the Surface Roughness of material. During leak detection process using RGA equipped Leak detector and tracer gas Helium, there will be a spill over of mass 3 and mass 2 to mass 4 which creates a background reading. Helium background will have contribution of Hydrogen too. So it is necessary to ensure the low OGR of Hydrogen. To achieve an effective leak test it is required to obtain a background below 1 × 10-8 mbar 1 s-1 and hence the maximum Outgassing rate of IWS Materials should comply with the maximum Outgassing rate required for hydrogen i.e. 1 x 10-10 mbar 1 s-1 cm-2 at room temperature. As IWS Materials are special materials developed for ITER project, it is necessary to ensure the compliance of Outgassing rate with the requirement. There is a possibility of diffusing the gasses in material at the time of production. So, to validate the production process of materials as well as manufacturing of final product from this material, three coupons of each IWS material have been manufactured with the same technique which is being used in manufacturing of IWS blocks. Manufacturing records of these coupons have been approved by ITER-IO (International Organization). Outgassing rates of these coupons have been measured at room temperature and found in acceptable limit to obtain the required Helium Background. On the basis of these measurements, test reports have been generated and got approved by IO. This paper will describe the preparation, characteristics and cleaning procedure of samples, description of the system, Outgassing rate Measurement of these samples to ensure the accurate leak detection.
Zimmitti, Giuseppe; Vauthey, Jean-Nicolas; Shindoh, Junichi; Tzeng, Ching-Wei D.; Roses, Robert E.; Ribero, Dario; Capussotti, Lorenzo; Giuliante, Felice; Nuzzo, Gennaro; Aloia, Thomas A.
2013-01-01
Objective After hepatectomy, bile leaks remain a major cause of morbidity, cost, and disability. This study was designed to determine if a novel intraoperative Air Leak Test (ALT) would reduce the incidence of post-hepatectomy biliary complications. Study design Rates of postoperative biliary complications were compared between 103 patients who underwent ALT and 120 matched patients operated on before ALT was utilized. All study patients underwent major hepatectomy without bile duct resection at 3 high-volume hepatobiliary centers between 2008 and 2012. ALT was performed by placement of a trans-cystic cholangiogram catheter to inject air into the biliary tree while the upper abdomen was filled with saline and the distal common bile duct was manually occluded. Uncontrolled bile ducts were identified by localization of air bubbles at the transection surface and were directly repaired. Results The 2 groups were similar in diagnosis, chemotherapy use, tumor number and size, resection extent, surgery duration, and blood loss (all p>0.05). Single or multiple uncontrolled bile ducts were intraoperatively detected and repaired in 62.1% of ALT vs. 8.3% of non-ALT patients (p<0.001). This resulted in a lower rate of postoperative bile leaks in ALT (1.9%) vs. non-ALT patients (10.8%, p=0.008). Independent risk factors for postoperative bile leaks included extended hepatectomy (p=0.031), caudate resection (p=0.02), and not performing ALT (p=0.002) [odds ratio (95% Confidence Interval): 3.8 (1.3–11.8), 4.0 (1.1–14.3), and 11.8 (2.4–58.8), respectively]. Conclusion ALT is an easily reproducible test that is highly effective for intraoperative detection and repair of open bile ducts, reducing the rate of postoperative bile leaks. PMID:24246619
Zimmitti, Giuseppe; Vauthey, Jean-Nicolas; Shindoh, Junichi; Tzeng, Ching-Wei D; Roses, Robert E; Ribero, Dario; Capussotti, Lorenzo; Giuliante, Felice; Nuzzo, Gennaro; Aloia, Thomas A
2013-12-01
After hepatectomy, bile leaks remain a major cause of morbidity, cost, and disability. This study was designed to determine if a novel intraoperative air leak test (ALT) would reduce the incidence of post-hepatectomy biliary complications. Rates of postoperative biliary complications were compared among 103 patients who underwent ALT and 120 matched patients operated on before ALT was used. All study patients underwent major hepatectomy without bile duct resection at 3 high-volume hepatobiliary centers between 2008 and 2012. The ALT was performed by placement of a transcystic cholangiogram catheter to inject air into the biliary tree, the upper abdomen was filled with saline, and the distal common bile duct was manually occluded. Uncontrolled bile ducts were identified by localization of air bubbles at the transection surface and were directly repaired. The 2 groups were similar in diagnosis, chemotherapy use, tumor number and size, resection extent, surgery duration, and blood loss (all, p > 0.05). Single or multiple uncontrolled bile ducts were intraoperatively detected and repaired in 62.1% of ALT vs 8.3% of non-ALT patients (p < 0.001). This resulted in a lower rate of postoperative bile leaks in ALT (1.9%) vs non-ALT patients (10.8%; p = 0.008). Independent risk factors for postoperative bile leaks included extended hepatectomy (p = 0.031), caudate resection (p = 0.02), and not performing ALT (p = 0.002) (odds ratio = 3.8; 95% CI, 1.3-11.8; odds ratio = 4.0; 95% CI, 1.1-14.3; and odds ratio = 11.8; 95% CI, 2.4-58.8, respectively). The ALT is an easily reproducible test that is highly effective for intraoperative detection and repair of open bile ducts, reducing the rate of postoperative bile leaks. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Intraoperatively Testing the Anastomotic Integrity of Esophagojejunostomy Using Methylene Blue.
Celik, S; Almalı, N; Aras, A; Yılmaz, Ö; Kızıltan, R
2017-03-01
Intraoperative testing of gastrointestinal anastomosis effectively ensures anastomotic integrity. This study investigated whether the routine use of methylene blue intraoperatively identified leaks to reduce the postoperative proportion of clinical leaks. This study retrospectively analyzed consecutive total gastrectomies performed from January 2007 to December 2014 in a university hospital setting by a general surgical group that exclusively used the methylene blue test. All surgeries were performed for gastric or junctional cancers (n = 198). All reconstructions (Roux-en Y esophagojejunostomy) were performed using a stapler. The methylene blue test was used in 108 cases (group 1) via a nasojejunal tube. No test was performed for the other 90 cases (group 2). Intraoperative leakage rate, postoperative clinical leakage rate, length of hospitalization, and mortality rate were the outcome measures. The intraoperative leakage rate was 7.4% in group 1. The postoperative clinical leakage rate was 8.6%. The postoperative clinical leakage rate was 3.7% in group 1 and 14.4% in group 2 (p = 0.007). There were no postoperative clinical leaks when an intraoperative leak led to concomitant intraoperative repair. The median length of hospital stay was 6 days in group 1 and 8 days in group 2 (p < 0.001). One death occurred in each group. No test-related complications were observed. The methylene blue test for esophagojejunostomy is a safe and reliable method for the assessment of anastomosis integrity, especially in cases with difficult esophagojejunostomic construction.
Hazardous Gas Leak Analysis in the Space Shuttle
NASA Technical Reports Server (NTRS)
Barile, Ronald G.
1991-01-01
Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.
Skull Base Cerebrospinal Fluid Leakage Control with a Fibrin-Based Composite Tissue Adhesive
Rock, Jack P.; Sierra, David H.; Castro-Moure, Frederico; Jiang, Feng
1996-01-01
Cerebrospinal fluid (CSF) leaks can be responsible for significant patient morbidity and mortality. While the majority of leaks induced after head trauma will seal without intervention, spontaneous or surgically-induced leaks often require operative repair. Many modifications on standard surgical technique are available for repair of CSF fistulae, but none assures adequate closure. We have studied the efficacy of a novel fibrin-based composite tissue adhesive (CTA) for closure of experimentally-induced CSF leaks in rats. Fistulae were created in two groups of animals. Two weeks after creation of the leaks, the animals were sacrificed and analyzed for persistence of leak. A 58% leakage rate was noted in the control group (n = 12), and no leaks were noted in the experimental group closed after application of CTA to the surgical defect followed by skin closure (n = 11). Comparing the control group to the experimental group, results were statistically significant (p = 0.015). These data suggest that CTA may be effective as an adjunct for the closure of CSF fistulae. ImagesFigure 2Figure 3 PMID:17170969
Sammour, Tarik; Hayes, Ian P; Jones, Ian T; Steel, Malcolm C; Faragher, Ian; Gibbs, Peter
2018-01-01
There is conflicting evidence regarding the oncological impact of anastomotic leak following colorectal cancer surgery. This study aims to test the hypothesis that anastomotic leak is independently associated with local recurrence and overall and cancer-specific survival. Analysis of prospectively collected data from multiple centres in Victoria between 1988 and 2015 including all patients who underwent colon or rectal resection for cancer with anastomosis was presented. Overall and cancer-specific survival rates and rates of local recurrence were compared using Cox regression analysis. A total of 4892 patients were included, of which 2856 had completed 5-year follow-up. The overall anastomotic leak rate was 4.0%. Cox regression analysis accounting for differences in age, sex, body mass index, American Society of Anesthesiologists score and tumour stage demonstrated that anastomotic leak was associated with significantly worse 5-year overall survival (χ 2 = 6.459, P = 0.011) for colon cancer, but only if early deaths were included. There was no difference in 5-year colon cancer-specific survival (χ 2 = 0.582, P = 0.446) or local recurrence (χ 2 = 0.735, P = 0.391). For rectal cancer, there was no difference in 5-year overall survival (χ 2 = 0.266, P = 0.606), cancer-specific survival (χ 2 = 0.008, P = 0.928) or local recurrence (χ 2 = 2.192, P = 0.139). Anastomotic leak may reduce 5-year overall survival in colon cancer patients but does not appear to influence the 5-year overall survival in rectal cancer patients. There was no effect on local recurrence or cancer-specific survival. © 2016 Royal Australasian College of Surgeons.
Leaking in history space: A way to analyze systems subjected to arbitrary driving
NASA Astrophysics Data System (ADS)
Kaszás, Bálint; Feudel, Ulrike; Tél, Tamás
2018-03-01
Our aim is to unfold phase space structures underlying systems with a drift in their parameters. Such systems are non-autonomous and belong to the class of non-periodically driven systems where the traditional theory of chaos (based e.g., on periodic orbits) does not hold. We demonstrate that even such systems possess an underlying topological horseshoe-like structure at least for a finite period of time. This result is based on a specifically developed method which allows to compute the corresponding time-dependent stable and unstable foliations. These structures can be made visible by prescribing a certain type of history for an ensemble of trajectories in phase space and by analyzing the trajectories fulfilling this constraint. The process can be considered as a leaking in history space—a generalization of traditional leaking, a method that has become widespread in traditional chaotic systems, to leaks depending on time.
Single-Shell Tanks Leak Integrity Elements/ SX Farm Leak Causes and Locations - 12127
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girardot, Crystal; Harlow, Don; Venetz, Theodore
2012-07-01
Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-91F Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1.more » Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal 1-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX- 111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and dry-wells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching. (authors)« less
SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127
DOE Office of Scientific and Technical Information (OSTI.GOV)
VENETZ TJ; WASHENFELDER D; JOHNSON J
2012-01-25
Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1.more » Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design - working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching.« less
Varela, Gonzalo; Jiménez, Marcelo F; Novoa, Nuria Maria; Aranda, José Luis
2009-01-01
Since there are no data in the literature regarding variability in the management of postoperative pleural drainages, we have designed a prospective randomized study aimed at measuring inter-observer variability in deciding when to withdraw chest tubes after lung resection and to evaluate if the use of an electronic device to measure postoperative air leak decreases clinical practice variations. Sixty-one patients undergoing pulmonary resection were randomly assigned to one of the following groups: digital group (electronic measure of pleural air leak using Millicore AB DigiVent chest drainage system) or traditional group (standard water seal pleural chamber). Chest tube withdrawal criteria were established in advance. During morning rounds, two thoracic surgeons with comparable clinical experience and blinded to the decision of their counterpart, evaluated chest tube withdrawal criteria and noted whether the tube should be withdrawn or not. Inter-observer variability kappa index and global, positive, and negative agreement rates were calculated on 2 x 2 tables. Each observation episode was considered in the calculation. Fifty-four observations were recorded in the traditional group. Kappa coefficient was 0.37 (overall agreement rate: 0.58; positive agreement rate: 0.72; and negative agreement rate: 0.64). In the digital group, 67 observations were recorded. Kappa coefficient was 0.88 (overall agreement rate: 0.94; positive agreement rate 0.94; and negative agreement rate 0.94). We have demonstrated a high rate of disagreement related to the indication to remove chest tubes after lung resection and the improvement of the agreement rate with the use of an electronic device to measure postoperative air leak and pleural pressures.
Testing of heat exchangers in membrane oxygenators using air pressure.
Hamilton, Carole; Stein, Jutta; Seidler, Rainer; Kind, Robert; Beck, Karin; Tosok, Jürgen; Upterfofel, Jörg
2006-03-01
All heat exchangers (HE) in membrane oxygenators are tested by the manufacturer for water leaks during the production phase. However, for safety reasons, it is highly recommended that HEs be tested again before clinical use. The most common method is to attach the heater-cooler to the HE and allow the water to recirculate for at least 10 min, during which time a water leak should be evident. To improve the detection of water leaks, a test was devised using a pressure manometer with an integrated bulb used to pressurize the HE with air. The cardiopulmonary bypass system is set up as per protocol. A pressure manometer adapted to a 1/2" tubing is connected to the water inlet side of the oxygenator. The water outlet side is blocked with a short piece of 1/2" deadend tubing. The HE is pressurized with 250 mmHg for at least 30 sec and observed for any drop. Over the last 2 years, only one oxygenator has been detected with a water leak in which the air-method leaktest was performed. This unit was sent back to the manufacturer who confirmed the failure. Even though the incidence of water leaks is very low, it does occur and it is, therefore, important that all HEs are tested before they are used clinically. This method of using a pressure manometer offers many advantages, as the HE can be tested outside of the operating room (OR), allowing earlier testing of the oxygenator, no water contact is necessary, and it is simple, easy and quick to perform.
An Explanation of the Varied Measurements of Gas Field Methane Leakage
NASA Astrophysics Data System (ADS)
Evans, W. F.; McHugh, M. J.
2014-12-01
In situ engineering measurements of natural gas well sites indicate leakage rates with a mean rate of 1.5% of the gas production rate from individual wells. These have been made at several gas basins using in situ measurements. These in situ engineering measurements are reported as the fugitive emission rates to the UNCCC by the EPA. On the other hand, atmospheric measurements at altitudes above the surface by several atmospheric groups indicate that gas fields are leaking at an average rate of over 9 %. Papers have been published in several highly reputable journals by government and university scientists. Both groups have been criticizing the methodologies of the opposite group. We propose that a more likely explanation is that both groups are correct. Although this appears as a direct conflict with one group on each side, a careful analysis shows that the two groups are measuring different air parcels. This is the only explanation which will explain the apparent conflicting situation. This can be understood if the basins in which the wells are sited are actually leaking from the bed rock formations in which the wells are drilled. If the geology of the natural gas basins is examined in detail, then the situation becomes understandable. Many basins contain gas in fault traps. These faults often leak, particularly if there is a small earthquake. The leaks can follow tilted layers, resulting in vertical transport of gas along the slanted layer cracks. This leakage may emerge into the atmosphere at large distances from the actual gas well under measurement. Fracking can obviously increase the leakage from a valley gas field. The methane leaks could alter the budgets of greenhouse gases reported by various gas producing countries by significant amounts. The potential increases and altered budgets for various countries as reported to the UNCCC are estimated and reported in this presentation. The fraction of these unreported leaks which should be reported will have to wait for the development of appropriate methodologies to determine how much of the observed leakage is natural and how much is due to natural gas exploitation.
Fugitive Methane Gas Emission Monitoring in oil and gas industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Levente
Identifying fugitive methane leaks allow optimization of the extraction process, can extend gas extraction equipment lifetime, and eliminate hazardous work conditions. We demonstrate a wireless sensor network based on cost effective and robust chemi-resistive methane sensors combined with real time analytics to identify leaks from 2 scfh to 10000 scfh. The chemi-resistive sensors were validated for sensitivity better than 1 ppm of methane plume detection. The real time chemical sensor and wind data is integrated into an inversion models to identify the location and the magnitude of the methane leak. This integrated solution can be deployed in outdoor environment formore » long term monitoring of chemical plumes.« less
Method for oil pipeline leak detection based on distributed fiber optic technology
NASA Astrophysics Data System (ADS)
Chen, Huabo; Tu, Yaqing; Luo, Ting
1998-08-01
Pipeline leak detection is a difficult problem to solve up to now. Some traditional leak detection methods have such problems as high rate of false alarm or missing detection, low location estimate capability. For the problems given above, a method for oil pipeline leak detection based on distributed optical fiber sensor with special coating is presented. The fiber's coating interacts with hydrocarbon molecules in oil, which alters the refractive indexed of the coating. Therefore the light-guiding properties of the fiber are modified. Thus pipeline leak location can be determined by OTDR. Oil pipeline lead detection system is designed based on the principle. The system has some features like real time, multi-point detection at the same time and high location accuracy. In the end, some factors that probably influence detection are analyzed and primary improving actions are given.
Seal Integrity of Selected Fuzes as Measured by Three Leak Test Methods
1976-09-01
the worst fuze from the seal standpoint. The M503A-2 fuze body is made from a cast aluminum alloy . The casting process leaves voids which, after...leak resistance of the joint. WDU4A/A The design of this fuze depends upon ultrasonic welding to seal lid to case. The specified leak test merely...test is probably one of the better leakage tests from an effectiveness standpoint. However, from lot quantities of 690 and 480, reject rates of 20% were
Sun, Da-Xin; Tan, Xiao-Dong; Gao, Feng; Xu, Jin; Cui, Dong-Xu; Dai, Xian-Wei
2015-01-01
Background Postoperative bile leak is a major surgical morbidity after curative resection with hepaticojejunostomy for hilar cholangiocarcinoma, especially in Bismuth-Corlette types III and IV. This retrospective study assessed the effectiveness and safety of an autologous hepatic round ligament flap (AHRLF) for reducing bile leak after hilar hepaticojejunostomy. Methods Nine type III and IV hilar cholangiocarcinoma patients were consecutively hospitalized for elective perihilar partial hepatectomy with hilar hepaticojejunostomy using an AHRLF between October 2009 and September 2013. The AHRLF was harvested to reinforce the perihilar hepaticojejunostomy. Main outcome measures included operative time, blood loss, postoperative recovery times, morbidity, bile leak, R0 resection rate, and overall survival. Results All patients underwent uneventful R0 resection with hilar hepaticojejunostomy. No patient experienced postoperative bile leak. Conclusions The AHRLF was associated with lack of bile leak after curative perihilar hepatectomy with hepaticojejunostomy for hilar cholangiocarcinoma, without compromising oncologic safety, and is recommended in selected patients. PMID:25938440
Assessing Surgeon Behavior Change after Anastomotic Leak in Colorectal Surgery
Simianu, Vlad V.; Basu, Anirban; Alfonso-Cristancho, Rafael; Thirlby, Richard C.; Flaxman, Abraham D.; Flum, David R.
2016-01-01
Background Recency effect suggests that people disproportionately value events from the immediate past when making decisions, but the extent of this impact on surgeons’ decisions is unknown. This study evaluates for recency effect in surgeons by examining use of preventative leak testing before and after colorectal operations with anastomotic leaks. Materials and Methods Prospective cohort of adult patients (≥18 years) undergoing elective colorectal operations at Washington State hospitals participating in the Surgical Care and Outcomes Assessment Program (2006–2013). The main outcome measure was surgeons’ change in leak testing from 6 months before to 6 months after an anastomotic leak occurred. Results Across 4,854 elective colorectal operations performed by 282 surgeons at 44 hospitals, there was a leak rate of 2.6% (n=124). The 40 leaks (32%) in which the anastomosis was not tested occurred across 25 surgeons. While the ability to detect an overall difference in use of leak testing was limited by small sample size, 9 (36%) of 25 surgeons increased their leak testing by 5 percent points or more after leaks in cases where the anastomosis was not tested. Surgeons who increased their leak testing more frequently performed operations for diverticulitis (45% vs 33%), more frequently began their cases laparoscopically (65% vs 37%), and had longer mean operative times (195±99 vs 148±87 minutes), all p<0.001. Conclusions Recency effect was demonstrated by only one-third of eligible surgeons. Understanding the extent to which clinical decisions may be influenced by recency effect may be important in crafting quality improvement initiatives that require clinician behavior change. PMID:27664886
Method and apparatus for measuring the gas permeability of a solid sample
Carstens, D.H.W.
1984-01-27
The disclosure is directed to an apparatus and method for measuring the permeability of a gas in a sample. The gas is allowed to reach a steady flow rate through the sample. A measurable amount of the gas is collected during a given time period and then delivered to a sensitive quadrupole. The quadrupole signal, adjusted for background, is proportional to the amount of gas collected during the time period. The quadrupole can be calibrated with a standard helium leak. The gas can be deuterium and the sample can be polyvinyl alcohol.
Harper, M E; Brand, M D
1994-08-01
Thyroid hormones have well-known effects on oxidative phosphorylation, but there is little quantitative information on their important sites of action. We have used top-down elasticity analysis, an extension of metabolic control analysis, to identify the sites of action of thyroid hormones on oxidative phosphorylation in rat hepatocytes. We divided the oxidative phosphorylation system into three blocks of reactions: the substrate oxidation subsystem, the phosphorylating subsystem, and the mitochondrial proton leak subsystem and have identified those blocks of reactions whose kinetics are significantly changed by hyperthyroidism. Our results show significant effects on the kinetics of the proton leak and the phosphorylating subsystems. Quantitative analyses revealed that 43% of the increase in resting respiration rate in hyperthyroid hepatocytes compared with euthyroid hepatocytes was due to differences in the proton leak and 59% was due to differences in the activity of the phosphorylating subsystem. There were no significant effects on the substrate oxidation subsystem. Changes in nonmitochondrial oxygen consumption accounted for -2% of the change in respiration rate. Top-down control analysis revealed that the distribution of control over the rates of mitochondrial oxygen consumption, ATP synthesis and consumption, and proton leak and over mitochondrial membrane potential (delta psi m) was similar in hepatocytes from hyperthyroid and littermate-paired euthyroid controls. The results of this study include the first complete top-down elasticity and control analyses of oxidative phosphorylation in hepatocytes from hyperthyroid rats.
Felbaum, Daniel R; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M
2016-01-01
Introduction: Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk. Methods: A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboccipital craniectomy or craniotomy. Patient data was reviewed for craniotomy or craniectomy, dural graft, and/or sealant use as well as CSF complications. A pseudomeningocele was defined as a subcutaneous collection of cerebrospinal fluid palpable clinically and confirmed on imaging. A CSF leak was defined as a CSF-cutaneous fistula manifested by CSF leaking through the wound. All patients underwent regular postoperative visits of two weeks, one month, and three months. Results: Our retrospective review identified 33 patients matching the inclusion criteria. Overall, our cohort had a 21% (7/33) rate of clinical and radiographic pseudomeningocele formation with 9% (3/33) requiring surgical revision or a separate procedure. The rate of clinical and radiographic pseudomeningocele formation in the myofascial cuff preservation technique was less than standard techniques (12% and 31%, respectively). Revision or further surgical procedures were also reduced in the myofascial cuff preservation technique vs. the standard technique (6% vs 13%). Conclusions: Preservation of the myofascial cuff during posterior fossa surgery is a simple and adoptable technique that reduces the rate of pseudomeningocele formation and CSF leak as compared with standard techniques. PMID:28133584
Lu, T Z; Kostelecki, W; Sun, C L F; Dong, N; Pérez Velázquez, J L; Feng, Z-P
2016-12-01
The spontaneous rhythmic firing of action potentials in pacemaker neurons depends on the biophysical properties of voltage-gated ion channels and background leak currents. The background leak current includes a large K + and a small Na + component. We previously reported that a Na + -leak current via U-type channels is required to generate spontaneous action potential firing in the identified respiratory pacemaker neuron, RPeD1, in the freshwater pond snail Lymnaea stagnalis. We further investigated the functional significance of the background Na + current in rhythmic spiking of RPeD1 neurons. Whole-cell patch-clamp recording and computational modeling approaches were carried out in isolated RPeD1 neurons. The whole-cell current of the major ion channel components in RPeD1 neurons were characterized, and a conductance-based computational model of the rhythmic pacemaker activity was simulated with the experimental measurements. We found that the spiking rate is more sensitive to changes in the Na + leak current as compared to the K + leak current, suggesting a robust function of Na + leak current in regulating spontaneous neuronal firing activity. Our study provides new insight into our current understanding of the role of Na + leak current in intrinsic properties of pacemaker neurons. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Hawkins, Alexander T; Dharmarajan, Sekhar; Wells, Katerina K; Krishnamurty, Devi Mukkai; Mutch, Matthew G; Glasgow, Sean C
2016-10-01
Anastomotic leak is one of the most feared complications of gastrointestinal surgery. Surgeons routinely perform a diverting loop ileostomy (DLI) to protect high-risk colo-rectal anastomoses. The NSQIP database was queried from 2012 to 2013 for patients undergoing open ileo-colic resection with and without a DLI. The primary outcome was the development of any anastomotic leak-including those managed operatively and non-operatively. Secondary outcomes included overall complication rate, return to the OR, readmission, and 30-day mortality. Four thousand one hundred fifty-nine patients underwent open ileo-colic resection during the study period. One hundred eighty-six (4.5 %) underwent a DLI. Factors associated with the addition of a DLI included emergency surgery, pre-operative sepsis, and IBD. There were 197 anastomotic leaks (4.7 %) with 100 patients requiring reoperation (2.4 %). DLI was associated with a decrease in anastomotic leaks requiring reoperation (DLI vs no DLI: 0 (0 %) vs 100 (2.5 %); p = 0.02) and with increased readmission (OR 1.93; 95 % CI 1.30-2.85; p = 0.001). DLI is rarely used for open ileo-colic resection. There were no serious leaks requiring reoperation in the DLI group. A DLI was associated with an almost two-fold increase in the odds of readmission. Surgeons must weigh the reduction in serious leak rate with postoperative morbidity when considering a DLI for open ileo-colic resection.
40 CFR 63.7330 - What are my monitoring requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... relative change in particulate matter loadings using a bag leak detection system according to the... integrity of the baghouse through quarterly visual inspections of the baghouse interior for air leaks; and... must at all times monitor the pressure drop and water flow rate using a CPMS according to the...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
Investigation of the Leak Response of a Carbon-Fiber Laminate Loaded in Biaxial Tension
NASA Technical Reports Server (NTRS)
Jackson, Wade C.; Ratcliffe, James G.
2013-01-01
Designers of pressurized structures have been reluctant to use composite materials because of concerns over leakage. Biaxial stress states are expected to be the worst-case loading condition for allowing leakage to occur through microcracks. To investigate the leakage behavior under in-plane biaxial loading, a cruciform composite specimen was designed that would have a relatively large test section with a uniform 1:1 biaxial loading ratio. A 7.6-cm-square test section was desired for future investigations of the leakage response as a result of impact damage. Many iterations of the cruciform specimen were evaluated using finite element analysis to reduce stress concentrations and maximize the size of the uniform biaxial strain field. The final design allowed the specimen to go to relatively high biaxial strain levels without incurring damage away from the test section. The specimen was designed and manufactured using carbon/epoxy fabric with a four-ply-thick, quasi-isotropic, central test section. Initial validation and testing were performed on a specimen without impact damage. The specimen was tested to maximum biaxial strains of approximately 4500micro epsilon without apparent damage. A leak measurement system containing a pressurized cavity was clamped to the test section and used to measure the flow rate through the specimen. The leakage behavior of the specimen was investigated for pressure differences up to 172 kPa
NASA Astrophysics Data System (ADS)
Gourdji, S.; Yadav, V.; Karion, A.; Mueller, K. L.; Kort, E. A.; Conley, S.; Ryerson, T. B.; Nehrkorn, T.
2017-12-01
The ability of atmospheric inverse models to detect, spatially locate and quantify emissions from large point sources in urban domains needs improvement before inversions can be used reliably as carbon monitoring tools. In this study, we use the Aliso Canyon natural gas leak from October 2015 to February 2016 (near Los Angeles, CA) as a natural tracer experiment to assess inversion quality by comparison with published estimates of leak rates calculated using a mass balance approach (Conley et al., 2016). Fourteen dedicated flights were flown in horizontal transects downwind and throughout the duration of the leak to sample CH4 mole fractions and collect meteorological information for use in the mass-balance estimates. The same CH4 observational data were then used here in geostatistical inverse models with no prior assumptions about the leak location or emission rate and flux sensitivity matrices generated using the WRF-STILT atmospheric transport model. Transport model errors were assessed by comparing WRF-STILT wind speeds, wind direction and planetary boundary layer (PBL) height to those observed on the plane; the impact of these errors in the inversions, and the optimal inversion setup for reducing their influence was also explored. WRF-STILT provides a reasonable simulation of true atmospheric conditions on most flight dates, given the complex terrain and known difficulties in simulating atmospheric transport under such conditions. Moreover, even large (>120°) errors in wind direction were found to be tolerable in terms of spatially locating the leak rate within a 5-km radius of the actual site. Errors in the WRF-STILT wind speed (>50%) and PBL height have more negative impacts on the inversions, with too high wind speeds (typically corresponding with too low PBL heights) resulting in overestimated leak rates, and vice-versa. Coarser data averaging intervals and the use of observed wind speed errors in the model-data mismatch covariance matrix are shown to help reduce the influence of transport model errors, by averaging out compensating errors and de-weighting the influence of problematic observations. This study helps to enable the integration of aircraft measurements with other tower-based data in larger inverse models that can reliably detect, locate and quantify point source emissions in urban areas.
NASA Technical Reports Server (NTRS)
Buckley, Theresa M.
1988-01-01
Following the Challenger tragedy, an evaluation of the integrated main propulsion system flight data revealed a premature decay in the hydrogen external tank ullage pressure. A reconstruction of predicted ullage pressure versus time indicated an inconsistency between predicted and measured ullage pressure starting at approximately 65.5 seconds into the flight and reaching a maximum value between 72 and 72.9 seconds. This discrepancy could have been caused by a hydrogen gas leak or by a liquied hydrogen leak that occurred either in the pressurization system or in the external tank. The corresponding leak rates over the time interval from 65.5 to 72.9 seconds were estimated to range from 0.28 kg/s (0.62 lbm/s) + or - 41 percent to between 0.43 and 0.51kg/s (0.94 and 1.12lbs/s) + or - 1 percent for a gas leak and from 72.9 kg/s (160.5 lbs/s) + or - 41 percent to between 111.6 and 133.2 kg/s (245.8 and 293.3 lbs/s) + or - 1 percent for a liquid leak. No speculation is made to ascertain whether the leak is liquid or gas, as this cannot be determined from the analysis performed. Four structural failures in the hydrogen external tank were considered to explain the leak rates. A break in the 5-cm (2 in) pressurization line, in the 13-cm (5 in) vent line, or in the 43-cm (17 in) feedline is not likely. A break in the 10-cm (4 in) recirculation line with a larger structural failure occurring in the 72 to 73-second time period, the time of the visibly identified premature pressure decay, does seem plausible and the most likely of the four modes considered. These modes are not all-inclusive and do not preclude the possibility of a leak elsewhere in the tank.
NASA Astrophysics Data System (ADS)
Ryerson, T. B.; Aikin, K. C.; Angevine, W. M.; Atlas, E. L.; Blake, D. R.; Brock, C. A.; Fehsenfeld, F. C.; Gao, R.-S.; de Gouw, J. A.; Fahey, D. W.; Holloway, J. S.; Lack, D. A.; Lueb, R. A.; Meinardi, S.; Middlebrook, A. M.; Murphy, D. M.; Neuman, J. A.; Nowak, J. B.; Parrish, D. D.; Peischl, J.; Perring, A. E.; Pollack, I. B.; Ravishankara, A. R.; Roberts, J. M.; Schwarz, J. P.; Spackman, J. R.; Stark, H.; Warneke, C.; Watts, L. A.
2011-04-01
The fate of deepwater releases of gas and oil mixtures is initially determined by solubility and volatility of individual hydrocarbon species; these attributes determine partitioning between air and water. Quantifying this partitioning is necessary to constrain simulations of gas and oil transport, to predict marine bioavailability of different fractions of the gas-oil mixture, and to develop a comprehensive picture of the fate of leaked hydrocarbons in the marine environment. Analysis of airborne atmospheric data shows massive amounts (˜258,000 kg/day) of hydrocarbons evaporating promptly from the Deepwater Horizon spill; these data collected during two research flights constrain air-water partitioning, thus bioavailability and fate, of the leaked fluid. This analysis quantifies the fraction of surfacing hydrocarbons that dissolves in the water column (˜33% by mass), the fraction that does not dissolve, and the fraction that evaporates promptly after surfacing (˜14% by mass). We do not quantify the leaked fraction lacking a surface expression; therefore, calculation of atmospheric mass fluxes provides a lower limit to the total hydrocarbon leak rate of 32,600 to 47,700 barrels of fluid per day, depending on reservoir fluid composition information. This study demonstrates a new approach for rapid-response airborne assessment of future oil spills.
Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berg, John M.
Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gasmore » composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10 -7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10 -7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10 -5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10 -5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10 -7 std cc/sec.« less
Assessing surgeon behavior change after anastomotic leak in colorectal surgery.
Simianu, Vlad V; Basu, Anirban; Alfonso-Cristancho, Rafael; Thirlby, Richard C; Flaxman, Abraham D; Flum, David R
2016-10-01
Recency effect suggests that people disproportionately value events from the immediate past when making decisions, but the extent of this impact on surgeons' decisions is unknown. This study evaluates for recency effect in surgeons by examining use of preventative leak testing before and after colorectal operations with anastomotic leaks. Prospective cohort of adult patients (≥18 y) undergoing elective colorectal operations at Washington State hospitals participating in the Surgical Care and Outcomes Assessment Program (2006-2013). The main outcome measure was surgeons' change in leak testing from 6 mo before to 6 mo after an anastomotic leak occurred. Across 4854 elective colorectal operations performed by 282 surgeons at 44 hospitals, there was a leak rate of 2.6% (n = 124). The 40 leaks (32%) in which the anastomosis was not tested occurred across 25 surgeons. While the ability to detect an overall difference in use of leak testing was limited by small sample size, nine (36%) of 25 surgeons increased their leak testing by 5% points or more after leaks in cases where the anastomosis was not tested. Surgeons who increased their leak testing more frequently performed operations for diverticulitis (45% versus 33%), more frequently began their cases laparoscopically (65% versus 37%), and had longer mean operative times (195 ± 99 versus 148 ± 87 min), all P < 0.001. Recency effect was demonstrated by only one-third of eligible surgeons. Understanding the extent to which clinical decisions may be influenced by recency effect may be important in crafting quality improvement initiatives that require clinician behavior change. Copyright © 2016 Elsevier Inc. All rights reserved.
Clogging of Manifolds with Evaporatively Frozen Propellants. Part 2; Analysis
NASA Technical Reports Server (NTRS)
Simmon, J. A.; Gift, R. D.; Spurlock, J. M.
1966-01-01
The mechanisms of evaporative freezing of leaking propellant and the creation of flow stoppages within injector manifolds is discussed. A quantitative analysis of the conditions, including the existence of minimum and maximum leak rates, for the accumulation of evaporatively frozen propellant is presented. Clogging of the injector manifolds of the Apollo SPS and the Gemini OAMS engines by the freezing of leaking propellant is predicted and the seriousness of the consequences are discussed. Based on the analysis a realistic evaluation of selected techniques to eliminate flow stoppages by frozen propellant is made.
Can the Risks of Cerebrospinal Fluid Leak After Vestibular Schwannoma Surgery Be Predicted?
Russel, Adrien; Hoffmann, Charles P; Nguyen, Duc T; Beurton, Renaud; Parietti-Winkler, Cécile
2017-02-01
Identifying predictive factors of cerebrospinal fluid (CSF) leak after translabyrinthine approach (TLA) for vestibular schwannoma. Retrospective study. Tertiary care center. All patients (n = 275) operated for a vestibular schwannoma by TLA between 2004 and 2013 were included. Vestibular schwannoma surgery by TLA. The rate of postoperative CSF leak considering the age, sex, body mass index (BMI), tumor staging, and duration of surgical procedure. A logistic regression model was used to identify the predictors and compute a biometric predictive model of CSF leak. Thirty-three patients (12.0%) developed a CSF leak after surgery. In a multivariable model, an increased risk of CSF leak was found for younger patients (OR 0.95, 95% CI 0.92-0.98), longer duration of surgery (OR 1.85, 95% CI 1.12-3.05), and the male sex (0 = male; 1 = female; OR 0.22, 95% CI 0.09-0.54), while also adjusting for BMI. The probability of developing a CSF leak after vestibular schwannoma surgery was calculated using a statistical prediction model, with a percentage of false negative of 7.0% and an overall correct prediction of 88.4%. The predictors of CSF leak after TLA for vestibular schwannoma are young age, male sex, longer duration of surgery, which adjusting for BMI. In this regard, the surgical team should adapt its management during pre- and postoperative period to decrease the likelihood of a leak.
Assessments of fluid friction factors for use in leak rate calculations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chivers, T.C.
1997-04-01
Leak before Break procedures require estimates of leakage, and these in turn need fluid friction to be assessed. In this paper available data on flow rates through idealized and real crack geometries are reviewed in terms of a single friction factor k It is shown that for {lambda} < 1 flow rates can be bounded using correlations in terms of surface R{sub a} values. For {lambda} > 1 the database is less precise, but {lambda} {approx} 4 is an upper bound, hence in this region flow calculations can be assessed using 1 < {lambda} < 4.
NASA Astrophysics Data System (ADS)
Gao, Yan; Liu, Yuyou; Ma, Yifan; Cheng, Xiaobin; Yang, Jun
2018-11-01
One major challenge currently facing pipeline networks across the world is the improvement of leak detection technologies in urban environments. There is an imperative to locate accurately leaks in buried water pipes to avoid serious environmental, social and economic consequences. Much attention has been paid to time delay estimation (TDE) in determining the position of a leak by utilising cross-correlation, which has been proven to be effective with varying degrees of success over the past half century. Previous research in published literature has demonstrated the effectiveness of the pre-whitening process for accentuating the peak in the cross-correlation associated with the time delay. This paper is concerned with the implementation of the differentiation process for TDE, with particular focus on the problem of determining a leak in pipelines by means of pipe pressure measurements. Rather than the pre-whitening operation, the proposed cross-correlation via the differentiation process, termed here DIF, changes the characteristics of the pipe system so that the pipe effectively acts as a band-pass filter. This method has the potential to eliminate some ambiguity caused by the interference at low frequencies and to allow more high frequency information to pass. Given an appropriate differentiation order, a more pronounced and reliable peak is obtained in the cross-correlation result. The use of differentiation process may provide a viable cross-correlation method suited to water leak detection. Its performance in relation to leak detection is further compared to the basic cross-correlation and pre-whitening methods for TDE in detecting a leak from actual PVC water pipes. Experimental results are presented to show an additional property of the DIF compensating for the resonance effects that may exist in cross-spectral density measurements, and hence better performance for TDE.
Tirnaksiz, M B; Deschamps, C; Allen, M S; Johnson, D C; Pairolero, P C
2005-01-01
Aqueous contrast swallow study is recommended as a screening procedure for the evaluation of esophageal anastomotic integrity following esophagectomy. The aim of this study was to assess the accuracy of water-soluble contrast swallow screening as a predictor of clinically significant anastomotic leak in patients with esophagectomy. The records of 505 consecutive patients undergoing esophagectomy in Mayo Clinic from January 1991 through December 1995 were retrospectively reviewed. 464 (92%) patients had water-soluble contrast swallows performed in the early postoperative period (median postoperative day 7, range 4-11 days). A total of 39 radiological leaks were obtained but only 17 of these had clinical signs of anastomotic leakage. Furthermore, 25 patients who had normal swallow study developed a clinical anastomotic leak. There were therefore 22 (4.7%) false positive and 25 (5.4%) false negative results giving values for the specificity, sensitivity and false negative error rate of the radiological examination of 94.7, 40.4, and 59.5% respectively. Aspiration of the contrast agent was noted on fluoroscopy in 30 (6.5%) patients. Only 2 (0.4%) patients developed aqueous contrast agent-caused aspiration pneumonia. There was no procedure-related mortality. While radiological assessment of esophageal anastomoses in the early postoperative period using aqueous contrast agents appears to be a relatively safe procedure, the poor sensitivity and high false negative error rate of this technique, when performed on postoperative day 7 and in a series with clinical anastomotic leak rate of 9%, is insufficient for it to be worthwhile as a screening procedure. Copyright (c) 2005 S. Karger AG, Basel.
A primary standard for the calibration of sniffer test leak devices
NASA Astrophysics Data System (ADS)
Jousten, Karl; Becker, Ute
2009-10-01
Test leaks with a gas flow to atmospheric pressure are often called sniffer test leaks. They are used to calibrate leak detectors for sniffing applications. Sniffer test leaks need calibration against a standard. A primary standard for the calibration of sniffer test leaks with relatively low measurement uncertainties is described. It is assured that the measurement result is traceable to the relevant SI units and that there is a well-known and complete measurement uncertainty budget. The measurement range of the system is from 4 × 10-11 mol s-1 (corresponding to 10-4 Pa l s-1 at 23 °C) to 4 × 10-9 mol s-1 (10-2 Pa l s-1 at 23 °C), which is the most often needed range in industry of around 1 g loss per year of the cooling agent R134a. The temperature where the calibration can be carried out may vary from 18 °C to 30 °C. The flow rate of any test gas not condensing in this temperature range can be measured.
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2011 CFR
2011-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
NASA Technical Reports Server (NTRS)
Woronowicz, Michael; Abel, Joshua; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin;
2014-01-01
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.
NASA Technical Reports Server (NTRS)
Woronowicz, Michael S.; Abel, Joshua C.; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin;
2014-01-01
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system.An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (directionality).The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbmyr. to about 1 lbmday. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ramwake flows and structural shadowing within low Earth orbit.
Electrical detection of liquid lithium leaks from pipe joints.
Schwartz, J A; Jaworski, M A; Mehl, J; Kaita, R; Mozulay, R
2014-11-01
A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.
Biphasic decay of the Ca transient results from increased sarcoplasmic reticulum Ca leak
Sankaranarayanan, Rajiv; Li, Yatong; Greensmith, David J.; Eisner, David A.
2016-01-01
Key points Ca leak from the sarcoplasmic reticulum through the ryanodine receptor (RyR) reduces the amplitude of the Ca transient and slows its rate of decay.In the presence of β‐adrenergic stimulation, RyR‐mediated Ca leak produces a biphasic decay of the Ca transient with a fast early phase and a slow late phase.Two forms of Ca leak have been studied, Ca‐sensitising (induced by caffeine) and non‐sensitising (induced by ryanodine) and both induce biphasic decay of the Ca transient.Only Ca‐sensitising leak can be reversed by traditional RyR inhibitors such as tetracaine.Ca leak can also induce Ca waves. At low levels of leak, waves occur. As leak is increased, first biphasic decay and then slowed monophasic decay is seen. The level of leak has major effects on the shape of the Ca transient. Abstract In heart failure, a reduction in Ca transient amplitude and contractile dysfunction can by caused by Ca leak through the sarcoplasmic reticulum (SR) Ca channel (ryanodine receptor, RyR) and/or decreased activity of the SR Ca ATPase (SERCA). We have characterised the effects of two forms of Ca leak (Ca‐sensitising and non‐sensitising) on calcium cycling and compared with those of SERCA inhibition. We measured [Ca2+]i with fluo‐3 in voltage‐clamped rat ventricular myocytes. Increasing SR leak with either caffeine (to sensitise the RyR to Ca activation) or ryanodine (non‐sensitising) had similar effects to SERCA inhibition: decreased systolic [Ca2+]i, increased diastolic [Ca2+]i and slowed decay. However, in the presence of isoproterenol, leak produced a biphasic decay of the Ca transient in the majority of cells while SERCA inhibition produced monophasic decay. Tetracaine reversed the effects of caffeine but not of ryanodine. When caffeine (1 mmol l−1) was added to a cell which displayed Ca waves, the wave frequency initially increased before waves disappeared and biphasic decay developed. Eventually (at higher caffeine concentrations), the biphasic decay was replaced by slow decay. We conclude that, in the presence of adrenergic stimulation, Ca leak can produce biphasic decay; the slow phase results from the leak opposing Ca uptake by SERCA. The degree of leak determines whether decay of Ca waves, biphasic or monophasic, occurs. PMID:26537441
Fleetwood, V A; Gross, K N; Alex, G C; Cortina, C S; Smolevitz, J B; Sarvepalli, S; Bakhsh, S R; Poirier, J; Myers, J A; Singer, M A; Orkin, B A
2017-03-01
Anastomotic leak (AL) increases costs and cancer recurrence. Studies show decreased AL with side-to-side stapled anastomosis (SSA), but none identify risk factors within SSAs. We hypothesized that stapler characteristics and closure technique of the common enterotomy affect AL rates. Retrospective review of bowel SSAs was performed. Data included stapler brand, staple line oversewing, and closure method (handsewn, HC; linear stapler [Barcelona technique], BT; transverse stapler, TX). Primary endpoint was AL. Statistical analysis included Fisher's test and logistic regression. 463 patients were identified, 58.5% BT, 21.2% HC, and 20.3% TX. Covidien staplers comprised 74.9%, Ethicon 18.1%. There were no differences between stapler types (Covidien 5.8%, Ethicon 6.0%). However, AL rates varied by common side closure (BT 3.7% vs. TX 10.6%, p = 0.017), remaining significant on multivariate analysis. Closure method of the common side impacts AL rates. Barcelona technique has fewer leaks than transverse stapled closure. Further prospective evaluation is recommended. Copyright © 2017. Published by Elsevier Inc.
Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator
NASA Technical Reports Server (NTRS)
Ramspacher, Daniel J. (Inventor); Richard, James A. (Inventor)
2017-01-01
A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.
Ortiz, Héctor; Biondo, Sebastiano; Codina, Antonio; Ciga, Miguel Á; Enríquez-Navascués, José; Espín, Eloy; García-Granero, Eduardo; Roig, José Vicente
2016-04-01
This multicentre observational study aimed to determine the anastomotic leak rate in the hospitals included in the Rectal Cancer Project of the Spanish Society of Surgeons and examine whether hospital volume may contribute to any variation between hospitals. Hospital variation was quantified using a multilevel approach on prospective data derived from the multicentre database of all adenocarcinomas of the rectum operated by an anterior resection at 84 surgical departments from 2006 to 2013. The following variables were included in the analysis; demographics, American Society of Anaesthesiologists classification, use of defunctioning stoma, tumour location and stage, administration of neoadjuvant treatment, and annual volume of elective surgical procedures. A total of 7231 consecutive patients were included. The rate of anastomotic leak was 10.0%. Stratified by annual surgical volume hospitals varied from 9.9 to 11.3%. In multilevel regression analysis, the risk of anastomotic leak increased in male patients, in patients with tumours located below 12 cm from the anal verge, and advanced tumour stages. However, a defunctioning stoma seemed to prevent this complication. Hospital surgical volume was not associated with anastomotic leak (OR: 0.852, [0.487-1.518]; P=.577). Furthermore, there was a statistically significant variation in anastomotic leak between all departments (MOR: 1.475; [1.321-1.681]; P<0.001). Anastomotic leak varies significantly among hospitals included in the project and this difference cannot be attributed to the annual surgical volume. Copyright © 2015 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Gaseous Nitrogen Orifice Mass Flow Calculator
NASA Technical Reports Server (NTRS)
Ritrivi, Charles
2013-01-01
The Gaseous Nitrogen (GN2) Orifice Mass Flow Calculator was used to determine Space Shuttle Orbiter Water Spray Boiler (WSB) GN2 high-pressure tank source depletion rates for various leak scenarios, and the ability of the GN2 consumables to support cooling of Auxiliary Power Unit (APU) lubrication during entry. The data was used to support flight rationale concerning loss of an orbiter APU/hydraulic system and mission work-arounds. The GN2 mass flow-rate calculator standardizes a method for rapid assessment of GN2 mass flow through various orifice sizes for various discharge coefficients, delta pressures, and temperatures. The calculator utilizes a 0.9-lb (0.4 kg) GN2 source regulated to 40 psia (.276 kPa). These parameters correspond to the Space Shuttle WSB GN2 Source and Water Tank Bellows, but can be changed in the spreadsheet to accommodate any system parameters. The calculator can be used to analyze a leak source, leak rate, gas consumables depletion time, and puncture diameter that simulates the measured GN2 system pressure drop.
Identifying Patients at Higher Risk of Prolonged Air Leak After Lung Resection.
Gilbert, Sebastien; Maghera, Sonam; Seely, Andrew J; Maziak, Donna E; Shamji, Farid M; Sundaresan, Sudhir R; Villeneuve, Patrick J
2016-11-01
Predictive models of prolonged air leak have relied on information not always available preoperatively (eg, extent of resection, pleural adhesions). Our objective was to construct a model to identify patients at increased risk of prolonged air leak using preoperative factors exclusively. From 2012 to 2014, data on consecutive patients undergoing pulmonary resection were collected prospectively. Prolonged air leak was defined as lasting longer than 7 days and requiring hospitalization. Factors associated with the primary outcome (p < 0.2) were included in a multivariate model. Regression coefficients were used to develop a weighted risk score for prolonged air leak. Of 225 patients, 8% (18/225) experienced a prolonged air leak. Male gender (p = 0.08), smoking history (p = 0.03), body mass index (BMI) 25 or below (p < 0.01), Medical Research Council (MRC) dyspnea score above 1 (p = 0.06), and diffusion capacity for carbon monoxide below 80% (Dlco) (p = 0.01) were selected for inclusion in the final model. Weighted scores were male gender (1 point), BMI 25 or below (0.5 point), smoker (2 points), Dlco% below 80% (2 points), and MRC dyspnea score above 1 (1 point). The area under the receiver operating characteristic curve was 0.8 (95% confidence interval [CI] = 0.7 to 0.9]. An air leak score above 4 points offered the best combination of sensitivity (83% [95% CI = 58 to 96]) and specificity (65% [95% CI = 58 to 71]). A subgroup of lung resection patients at higher risk for a prolonged air leak can be effectively identified with the use of widely available, preoperative factors. The proposed scoring system is simple, is clinically relevant to the informed consent, and allows preoperative patient selection for interventions to reduce the risk of prolonged air leak. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Risk of anastomotic leak after laparoscopic versus open colectomy.
Murray, Alice C A; Chiuzan, Cody; Kiran, Ravi P
2016-12-01
Anastomotic leak following colorectal surgery is associated with significant morbidity and mortality. With the widespread adoption of laparoscopy, data from initial clinical trials evaluating the efficacy of laparoscopic when compared to open surgery may not currently be generalizable. We assess the risk of anastomotic leak after laparoscopic versus open colorectal resection using a nationwide database with standardized definitions. The 2012-2013 ACS-NSQIP targeted colectomy data were queried for all elective colorectal resections. Characteristics were compared for those patients undergoing laparoscopic versus open operations. Univariable and multivariable analyses, followed by a propensity score-matched analysis, were performed to assess the impact of laparoscopy on the development of an anastomotic leak. Of 23,568 patients, 3.4 % developed an anastomotic leak. Laparoscopic surgery was associated with a leak rate of 2.8 % (n = 425) and open surgery, 4.5 % (n = 378, p < 0.0001). Patients who developed a leak were more likely to die within 30 days of surgery (5.7 vs. 0.6 %, p < 0.0001). Patients who underwent laparoscopic surgery compared to open were younger (61 vs. 63 years, p = 0, p = 0.045) and with fewer comorbidities. On univariable analysis laparoscopic surgery was associated with reduced odds of developing an anastomotic leak (OR 0.60, p < 0.0001), and this remained after adjusting for all significant preoperative and disease-related confounders (OR 0.69, 95 % CI 0.58-0.82). A propensity score-matched analysis confirmed benefit of laparoscopic surgery over open surgery for anastomotic leak. Laparoscopic colectomy is safe and associated with reduced odds of developing an anastomotic leak following colectomy when controlling for patient-, disease- and procedure-related factors.
NASA Astrophysics Data System (ADS)
Smith, C. J.; Kim, B.; Zhang, Y.; Ng, T. N.; Beck, V.; Ganguli, A.; Saha, B.; Daniel, G.; Lee, J.; Whiting, G.; Meyyappan, M.; Schwartz, D. E.
2015-12-01
We will present our progress on the development of a wireless sensor network that will determine the source and rate of detected methane leaks. The targeted leak detection threshold is 2 g/min with a rate estimation error of 20% and localization error of 1 m within an outdoor area of 100 m2. The network itself is composed of low-cost, high-performance sensor nodes based on printed nanomaterials with expected sensitivity below 1 ppmv methane. High sensitivity to methane is achieved by modifying high surface-area-to-volume-ratio single-walled carbon nanotubes (SWNTs) with materials that adsorb methane molecules. Because the modified SWNTs are not perfectly selective to methane, the sensor nodes contain arrays of variously-modified SWNTs to build diversity of response towards gases with adsorption affinity. Methane selectivity is achieved through advanced pattern-matching algorithms of the array's ensemble response. The system is low power and designed to operate for a year on a single small battery. The SWNT sensing elements consume only microwatts. The largest power consumer is the wireless communication, which provides robust, real-time measurement data. Methane leak localization and rate estimation will be performed by machine-learning algorithms built with the aid of computational fluid dynamics simulations of gas plume formation. This sensor system can be broadly applied at gas wells, distribution systems, refineries, and other downstream facilities. It also can be utilized for industrial and residential safety applications, and adapted to other gases and gas combinations.
Assaying Mitochondrial Respiration as an Indicator of Cellular Metabolism and Fitness.
Smolina, Natalia; Bruton, Joseph; Kostareva, Anna; Sejersen, Thomas
2017-01-01
Mitochondrial respiration is the most important generator of cellular energy under most circumstances. It is a process of energy conversion of substrates into ATP. The Seahorse equipment allows measuring oxygen consumption rate (OCR) in living cells and estimates key parameters of mitochondrial respiration in real-time mode. Through use of mitochondrial inhibitors, four key mitochondrial respiration parameters can be measured: basal, ATP production-linked, maximal, and proton leak-linked OCR. This approach requires application of mitochondrial inhibitors-oligomycin to block ATP synthase, FCCP-to make the inner mitochondrial membrane permeable for protons and allow maximum electron flux through the electron transport chain, and rotenone and antimycin A-to inhibit complexes I and III, respectively. This chapter describes the protocol of OCR assessment in the culture of primary myotubes obtained upon satellite cell fusion.
Kissin, C M; Grundy, A
1987-01-01
Percutaneous transhepatic cholangiography (PTHC) is now a widely available, inexpensive investigation with a low incidence of complications, especially in the nonobstructed system, and a high success rate. Its role in the management of obstructive jaundice is well established but it is only infrequently performed in the investigation of persistent bile leakage following biliary tract surgery. Four cases are reported in which the superior demonstration of biliary anatomy provided by PTHC allowed successful identification of the site of postoperative biliary leakage. We compared PTHC with other diagnostic imaging techniques available and conclude that it is a safe, accurate, and reliable technique.
Thermographic Nondestructive Evaluation of the Space Shuttle Main Engine Nozzle
NASA Technical Reports Server (NTRS)
Walker, James L.; Lansing, Matthew D.; Russell, Samuel S.; Caraccioli, Paul; Whitaker, Ann F. (Technical Monitor)
2000-01-01
The methods and results presented in this summary address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.
Winward, Josh; Beattie, Ursula; Cipolli, William
2018-01-01
Among species, larger animals tend to live longer than smaller ones, however, the opposite seems to be true for dogs—smaller dogs tend to live significantly longer than larger dogs across all breeds. We were interested in the mechanism that may allow for small breeds to age more slowly compared with large breeds in the context of cellular metabolism and oxidative stress. Primary dermal fibroblasts from small and large breed dogs were grown in culture. We measured basal oxygen consumption (OCR), proton leak, and glycolysis using a Seahorse XF96 oxygen flux analyzer. Additionally, we measured rates of reactive species (RS) production, reduced glutathione (GSH) content, mitochondrial content, lipid peroxidation (LPO) damage and DNA (8-OHdg) damage. Our data suggests that as dogs of both size classes age, proton leak is significantly higher in older dogs, regardless of size class. We found that all aspects of glycolysis were significantly higher in larger breeds compared with smaller breeds. We found significant differences between age classes in GSH concentration, and a negative correlation between DNA damage in puppies and mean breed lifespan. Interestingly, RS production showed no differences across size and age class. Thus, large breed dogs may have higher glycolytic rates, and DNA damage, suggesting a potential mechanism for their decreased lifespan compared with small breed dogs. PMID:29694441
40 CFR Table 2 to Subpart Kkkkk of... - Operating Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
... stack. 2. Kiln equipped with a DIFF or DLS/FF a. If you use a bag leak detection system, initiate corrective action within 1 hour of a bag leak detection system alarm and complete corrective actions in... to the scrubber water, maintain the average scrubber chemical feed rate for each 3-hour block period...
40 CFR 63.1086 - How must I monitor for leaks to cooling water?
Code of Federal Regulations, 2012 CFR
2012-07-01
... exchange system or any combinations of heat exchangers such that, based on the rate of cooling water at the... detected a leak. (b) Individual heat exchangers. Monitor the cooling water at the entrance and exit of each heat exchanger for the HAP in Table 1 to this subpart (either total or speciated) or other...
40 CFR 63.1086 - How must I monitor for leaks to cooling water?
Code of Federal Regulations, 2013 CFR
2013-07-01
... exchange system or any combinations of heat exchangers such that, based on the rate of cooling water at the... detected a leak. (b) Individual heat exchangers. Monitor the cooling water at the entrance and exit of each heat exchanger for the HAP in Table 1 to this subpart (either total or speciated) or other...
40 CFR 63.1086 - How must I monitor for leaks to cooling water?
Code of Federal Regulations, 2014 CFR
2014-07-01
... exchange system or any combinations of heat exchangers such that, based on the rate of cooling water at the... detected a leak. (b) Individual heat exchangers. Monitor the cooling water at the entrance and exit of each heat exchanger for the HAP in Table 1 to this subpart (either total or speciated) or other...
40 CFR 63.1086 - How must I monitor for leaks to cooling water?
Code of Federal Regulations, 2011 CFR
2011-07-01
... exchange system or any combinations of heat exchangers such that, based on the rate of cooling water at the... detected a leak. (b) Individual heat exchangers. Monitor the cooling water at the entrance and exit of each heat exchanger for the HAP in Table 1 to this subpart (either total or speciated) or other...
Schiesser, Marc; Guber, Josef; Wildi, Stefan; Guber, Ivo; Weber, Markus; Muller, Markus K
2011-08-01
In up to 4% of laparoscopic Roux-en-Y gastric bypass (LRYGB) procedures, anastomotic leaks occur. Early detection of gastrointestinal leakage is important for successful treatment. Consequently, many centers advocate routine postoperative upper gastrointestinal (UGI) series. The aim of this study was to determine the utility of this practice after LRYGB. Eight hundred four consecutive patients undergoing LRYGB from June 2000 to April 2010 were analyzed prospectively. The first 382 patients received routine UGI series between the third and fifth postoperative days (group A). Thereafter, the test was only performed when clinical findings (tachycardia, fever, and drainage content) were suspicious for a leak of the gastrointestinal anastomosis (group B; n = 422). Overall, nine of 804 (1.1%) patients suffered from leaks at the gastroenterostomy. In group A, four of 382 (1%) patients had a leak, but only two were detected by the routine UGI series. This corresponds to a sensitivity of 50%. In group B, the sensitivity was higher with 80%. Specificities were comparable with 97% and 91%, respectively. Routine UGI series cost only 1.6% of the overall costs of a non-complicated gastric bypass procedure. With this leak rate and sensitivity, US $86,800 would have to be spent on 200 routine UGI series to find one leak which is not justified. This study shows that routine UGI series have a low sensitivity for the detection of anastomotic leaks after LRYGB. In most cases, the diagnosis is initiated by clinical findings. Therefore, routine upper gastrointestinal series are of limited value for the diagnosis of a leak.
Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles.
Campos, Josemberg Marins; Ferreira, Flávio Coelho; Teixeira, André F; Lima, Jones Silva; Moon, Rena C; D'Assunção, Marco Aurélio; Neto, Manoel Galvão
2016-08-01
Chronic leaks after laparoscopic sleeve gastrectomy (LSG) are often difficult to treat by endoscopy metallic stent. Septotomy has been indicated as an effective procedure, but the technical aspects have not been detailed in previous publications (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007; Baretta G, Campos J, Correia S, et al., Surg Endosc 29(7):1714-20, 2015; Campos JM, Pereira EF, Evangelista LF, et al., Obes Surg 21(10):1520-9, 2011). We herein present a video (6 min) demonstrating the maneuver principles of this technique, showing it as a safe and feasible approach. A 32-year-old male, with BMI 43.4 kg/m(2), underwent LSG. On the tenth POD, he presented with a leak and initially was managed with the following approach: laparoscopic exploration, drainage, endoclips, and 20-mm balloon dilation. However, the leak remained for a period of 6 months. On the endoscopy, a septum was identified between the leak site and gastric pouch, so it was decided to "reshape" this area by septotomy. Septotomy procedure: Sequential incisions were performed using argon plasma coagulation (APC) with 2.5 flow and 50 W (WEM, SP, Brazil) over the septum in order to allow communication between the perigastric cavity (leak site) and the gastric lumen. The principles below must be followed: (1) Scope position: the endoscopist's left hand holds the control body of the gastroscope while the right hand holds the insertion tube; the APC catheter has no need to be fixed. This avoids movements and unprogrammed maneuvers. (2) Before cutting, the septum is placed in the six o'clock position on the endoscopic view, by rotating the gastroscope. (3) The septum is sectioned until the bottom of the perigastric cavity (leak site). (4) That section is made towards the staple line. (5) Just after the septotomy, a Savory-Gilliard guidewire (Cook Medical, Indiana, USA) through the scope must be inserted until the duodenum, followed by 30-mm balloon (Rigiflex®, Boston Scientific, MA, USA) insertion. The balloon catheter must be firmly held during gradual inflation (maximum 10 psi) to avoid slippage and laceration. This allows increasing the gastric lumen. (6) Septotomy by electrocautery with a needle knife (Boston Scientific, MA, USA) can be made when an intensive fibrotic septum is present; bleeding is rare in this case. In this case, the endoclip previously used was removed from the septum with forceps to avoid heat transmission. Small staples visualized in the fistula orifice were not completely removed due to technical difficulties and friable tissue. Two sessions were performed in 15 days, resulting in leak closure. The patient was submitted to radiological control 1 week after the second session, which revealed fistula healing, without gastric stenosis. The nasoduodenal feeding tube remained for 7 days, when the patient started oral diet. This patient was followed for 18 months without recurrence. Septotomy and balloon dilation were initially performed on a difficult-to-treat chronic fistula after gastric bypass and named before as stricturotomy (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007). This procedure allows internal drainage of the fistula and deviates oral intake to the pouch. In addition, achalasia balloon dilation treats strictures and axis deviation of the gastric chamber, promoting reduction of the intragastric pressure. Septotomy and balloon dilation are technically feasible and might be useful in selected cases for closure of chronic leaks after LSG.
Xu, Yu; Liu, Yuliang; Xia, Chen; Gao, Pan; Liu, Jun-Ze
2013-02-01
The present study aimed to investigate the change of proton leak and discuss the role of cerebral uncoupling proteins (UCPs) and its regulatory molecules non-esterified fatty acid (NEFA) in high altitude mitochondrial oxidative phosphorylation deficiency. The model group animals were exposed to acute high altitude hypoxia, and the mitochondrial respiration, protein leak, UCPs abundance/activity and cerebral NEFA concentration were measured. We found that in the model group, cerebral mitochondrial oxidative phosphorylation was severely impaired with decreased ST3 respiration rate and ATP pool. Proton leak kinetics curves demonstrated an increase in proton leak; GTP binding assay pointed out that total cerebral UCPs activity significantly increased; Q-PCR and western blot showed upregulated expression of UCP4 and UCP5. Moreover, cerebral NEFA concentration increased. In conclusion, UCPs mediated proton leak is closely related to cerebral mitochondria oxidative phosphorylation deficiency during acute high altitude hypoxia and NEFA is involved in this signaling pathway.
Method for sealing remote leaks in an enclosure using an aerosol
Modera, Mark P.; Carrie, Francois R.
1999-01-01
The invention is a method and device for sealing leaks remotely by means of injecting a previously prepared aerosol into the enclosure being sealed according to a particular sealing efficiency defined by the product of a penetration efficiency and a particle deposition efficiency. By using different limits in the relationship between penetration efficiency and flowrate, the same method according the invention can be used for coating the inside of an enclosure. Specifically the invention is a method and device for preparing, transporting, and depositing a solid phase aerosol to the interior surface of the enclosure relating particle size, particle carrier flow rate, and pressure differential, so that particles deposited there can bridge and substantially seal each leak, with out providing a substantial coating at inside surfaces of the enclosure other than the leak. The particle size and flow parameters can be adjusted to coat the interior of the enclosure (duct) without substantial plugging of the leaks depending on how the particle size and flowrate relationships are chosen.
Faletra, F.; De Chiara, F.; Corno, R.; Passini, L.
1996-01-01
OBJECTIVE: To evaluate how often multiplane transoesophageal echocardiography yields new or complementary data in mitral prostheses in comparison with the exclusive use of biplane imaging. PATIENTS: 73 consecutive patients with mitral prostheses who underwent multiplane transoesophageal echocardiograpy between January 1993 and December 1994. METHODS: Biplane images (transverse and longitudinal planes) and multiplane images (transverse, longitudinal, and intermediate planes) were recorded on two separate videotapes. The data provided by multiplane transoesophageal echocardiography were evaluated as (a) new data (abnormalities missed by biplane imaging); (b) complementary data (better delineating lesions already visualised by biplane imaging); or (c) redundant data (data already provided by biplane imaging). RESULTS: Multiplane transoesophageal echocardiography revealed new abnormalities in seven patients (9.5%) (thrombi in three and paraprosthetic leaks in the remaining four) and complementary data in nine (12.3%). In patients with paraprosthetic regurgitation, the possibility of continuously visualising the sewing ring by means of sequential angulations allowed the circumferential extension of the leak to be measured. In seven patients with paravalvar regurgitation who underwent surgery, the extension of the leak as measured by the multiplane approach closely corresponded with the surgical data. CONCLUSIONS: In comparison with the exclusive use of biplane imaging, the multiplane approach added new or complementary data in a significant proportion of patients with mitral prostheses. The ability to obtain the sequential adjacent planes allowed a more reliable appraisal of the extension of the leak and other abnormalities. Images PMID:8697166
Outcomes of endoscopic repair of cerebrospinal fluid rhinorrhea without lumbar drains.
Adams, Austin S; Russell, Paul T; Duncavage, James A; Chandra, Rakesh K; Turner, Justin H
2016-11-01
Lumbar drains (LD) are commonly used during endoscopic repair of cerebrospinal fluid (CSF) rhinorrhea, either to facilitate graft healing or to monitor CSF fluid dynamics. However, the indications and necessity of LD placement remains controversial. The current study sought to evaluate endoscopic CSF leak repair outcomes in the setting of limited LD use. Patients who underwent endoscopic repair of CSF rhinorrhea between 2004 and 2014 were identified by a review of medical records. Demographic and clinical data were extracted and compared between patients who had surgery with and patients who had surgery without a perioperative LD. A univariate analysis was performed to identify factors predictive of recurrence. A total of 107 patients (116 surgical procedures) were identified, with a mean follow-up of 15.8 months. Eighty-eight of 107 patients (82.2%) had surgery without an LD. The mean hospital stay was 4.48 days in the LD group versus 1.03 days in the non-LD group (p < 0.00001). There was no difference in recurrence rate between the LD and non-LD groups. Predictors of recurrence included repair technique (p = 0.04) and size of defect (p = 0.005). Body mass index, leak site (ethmoid, sphenoid, frontal), and etiology (spontaneous, iatrogenic, traumatic) were not predictive of leak recurrence. Use of LDs in endoscopic CSF leak repair was not associated with reduced recurrence rates, regardless of leak etiology, and resulted in a significant increase in hospital length of stay. Although the use of perioperative LDs to monitor CSF dynamics may have some therapeutic and diagnostic advantages, it may not be associated with clinically significant improvements in patient outcomes or recurrence rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woronowicz, Michael; Blackmon, Rebecca; Brown, Martin
2014-12-09
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performancemore » to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.« less
Phalen, Robert N.; Wong, Weng kee
2012-01-01
Background: The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. Objectives: This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Methods: Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Results: Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm−2 were about four times less likely to leak. Conclusions: On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break. PMID:22201179
Phalen, Robert N; Wong, Weng Kee
2012-05-01
The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm(-2) were about four times less likely to leak. On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break.
Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)
NASA Astrophysics Data System (ADS)
Šetina, Janez; Vičar, Martin; Pražák, Dominik
2015-01-01
The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Leak Location and Classification in the Space Shuttle Main Engine Nozzle by Infrared Testing
NASA Technical Reports Server (NTRS)
Russell, Samuel S.; Walker, James L.; Lansing, Mathew
2003-01-01
The Space Shuttle Main Engine (SSME) is composed of cooling tubes brazed to the inside of a conical structural jacket. Because of the geometry there are regions that can't be inspected for leaks using the bubble solution and low-pressure method. The temperature change due escaping gas is detectable on the surface of the nozzle under the correct conditions. The methods and results presented in this summary address the thermographic identification of leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute temperature change associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.
Lal, Dave R; Gadepalli, Samir K; Downard, Cynthia D; Ostlie, Daniel J; Minneci, Peter C; Swedler, Ruth M; Chelius, Thomas H; Cassidy, Laura; Rapp, Cooper T; Billmire, Deborah; Bruch, Steven; Burns, R Carland; Deans, Katherine J; Fallat, Mary E; Fraser, Jason D; Grabowski, Julia; Hebel, Ferdynand; Helmrath, Michael A; Hirschl, Ronald B; Kabre, Rashmi; Kohler, Jonathan; Landman, Matthew P; Leys, Charles M; Mak, Grace Z; Raque, Jessica; Rymeski, Beth; Saito, Jacqueline M; St Peter, Shawn D; von Allmen, Daniel; Warner, Brad W; Sato, Thomas T
2017-06-01
Perioperative management of infants with esophageal atresia and tracheoesophageal fistula (EA/TEF) is frequently based on surgeon experience and dogma rather than evidence-based guidelines. This study examines whether commonly perceived important aspects of practice affect outcome in a contemporary multi-institutional cohort of patients undergoing primary repair for the most common type of esophageal atresia anomaly, proximal EA with distal TEF. The Midwest Pediatric Surgery Consortium conducted a multicenter, retrospective study examining selected outcomes on infants diagnosed with proximal EA with distal TEF who underwent primary repair over a 5-year period (2009-2014), with a minimum 1-year follow up, across 11 centers. 292 patients with proximal EA and distal TEF who underwent primary repair were reviewed. The overall mortality was 6% and was significantly associated with the presence of congenital heart disease (OR 4.82, p=0.005). Postoperative complications occurred in 181 (62%) infants, including: anastomotic stricture requiring intervention (n=127; 43%); anastomotic leak (n=54; 18%); recurrent fistula (n=15; 5%); vocal cord paralysis/paresis (n=14; 5%); and esophageal dehiscence (n=5; 2%). Placement of a transanastomotic tube was associated with an increase in esophageal stricture formation (OR 2.2, p=0.01). Acid suppression was not associated with altered rates of stricture, leak or pneumonia (all p>0.1). Placement of interposing prosthetic material between the esophageal and tracheal suture lines was associated with an increased leak rate (OR 4.7, p<0.001), but no difference in the incidence of recurrent fistula (p=0.3). Empiric postoperative antibiotics for >24h were used in 193 patients (66%) with no difference in rates of infection, shock or death when compared to antibiotic use ≤24h (all p>0.3). Hospital volume was not associated with postoperative complication rates (p>0.08). Routine postoperative esophagram obtained on day 5 resulted in no delayed/missed anastomotic leaks or a difference in anastomotic leak rate as compared to esophagrams obtained on day 7. Morbidity after primary repair of proximal EA and distal TEF patients is substantial, and many common practices do not appear to reduce complications. Specifically, this large retrospective series does not support the use of prophylactic antibiotics beyond 24h and empiric acid suppression may not prevent complications. Use of a transanastomotic tube was associated with higher rates of stricture, and interposition of prosthetic material was associated with higher leak rates. Routine postoperative esophagram can be safely obtained on day 5 resulting in earlier initiation of oral feeds. Treatment study. III. Copyright © 2017 Elsevier Inc. All rights reserved.
Modeling the Risk of Fire/Explosion Due to Oxidizer/Fuel Leaks in the Ares I Interstage
NASA Technical Reports Server (NTRS)
Ring, Robert W.; Stott, James E.; Hales, Christy
2008-01-01
A significant flight hazard associated with liquid propellants, such as those used in the upper stage of NASA's new Ares I launch vehicle, is the possibility of leakage of hazardous fluids resulting in a catastrophic fire/explosion. The enclosed and vented interstage of the Ares I contains numerous oxidizer and fuel supply lines as well as ignition sources. The potential for fire/explosion due to leaks during ascent depends on the relative concentrations of hazardous and inert fluids within the interstage along with other variables such as pressure, temperature, leak rates, and fluid outgasing rates. This analysis improves on previous NASA Probabilistic Risk Assessment (PRA) estimates of the probability of deflagration, in which many of the variables pertinent to the problem were not explicitly modeled as a function of time. This paper presents the modeling methodology developed to analyze these risks.
Takamochi, Kazuya; Imashimizu, Kota; Fukui, Mariko; Maeyashiki, Tatsuo; Suzuki, Mikiko; Ueda, Takuya; Matsuzawa, Hironori; Hirayama, Shunki; Matsunaga, Takeshi; Oh, Shiaki; Suzuki, Kenji
2017-07-01
We sought to evaluate the clinical utility of chest tube management after pulmonary resection based on objective digital monitoring of pleural pressure and digital surveillance for air leaks. We prospectively recorded the perioperative data of 308 patients who underwent pulmonary resection between December 2013 and January 2016. We used information from a digital monitoring thoracic drainage system to measure peak air leakage during the first 24 hours after the operation, patterns of air leakage over the first 72 hours, and patterns of pleural pressure changes until the chest tubes were removed. There were 240 patients with lung cancer and 68 patients with other diseases. The operations included 49 wedge resections, 58 segmentectomies, and 201 lobectomies. A postoperative air leak was observed in 61 patients (20%). A prolonged air leak exceeding 20 mL/min lasting 5 days or more was observed in 18 patients (5.8%). Multivariate analysis of various perioperative factors showed forced expiratory volume in 1 second below 70%, patterns of air leakage, defined as exacerbating and remitting or without a trend toward improvement, and peak air leakage of 100 mL/min or more were significant positive predictors of prolonged air leak. Fluctuations in pleural pressure occurred just after the air leakage rate decreased to less than 20 mL/min. Digital monitoring of peak air leakage and patterns of air leakage were useful for predicting prolonged air leak after pulmonary resection. Information on the disappearance of air leak could be derived from the change in the rate of air leakage and from the increase in fluctuation of pleural pressure. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
El-Gendi, Ahmed M; El-Shafei, Mohamed; Bedewy, Essam
2018-03-12
Bile leak is the main cause of morbidity and mortality after surgery for hydatid liver cysts. Aim was to assess the role of prophylactic endoscopic sphincterotomy (ES) in reducing postoperative bile leak in patients undergoing partial cystectomy. Fifty-four patients with hepatic hydatid cyst met inclusion criteria, 27 were excluded or declined to participate. Twenty-six women and 28 men (mean age 44.6 ± 10.1, range: 22-61 years) were randomly assigned to either group I with ES (n = 27) or group II without ES (n = 27). Demographics and clinical, laboratory, and radiological characteristics of cysts were not statistically different between two groups. Group I had a significant decrease in bile leak rate compared with group II (11.1% versus 40.7%, P = .013), with significantly shorter duration of hospital stay (P < .0001). Biliary fistula in group I had significantly lower daily output (100 mL/day versus 350 mL/day) with gradual reduction till stoppage of leak in 3-4 days without intervention. Biliary fistula in group II had a significantly higher need for biliary intervention through postoperative endoscopic retrograde cholangiopancreatography with ES compared with biliary fistula in group I ( FE P = .002), with significantly longer mean time of fistula closure (P = .011) and longer time to drain removal (P < .0001). Nonbiliary complications were comparable between two groups. Prophylactic ES provides significant reduction in postoperative bile leak rate with shorter hospital stay after partial cystectomy of hydatid cyst. Biliary fistula in patients with ES has significantly lower daily output with shorter time of drain removal and shorter time to closure than patients without ES.
Páramo, M; García-Barquín, P; Carrillo, M; Millor Muruzábal, M; Vivas, I; Bilbao, J I
To analyze the safety and efficacy of percutaneous placement of coated self-expanding metallic stents (SEMS) in patients with biliary leaks. This ethics committee at our center approved this study. We retrospectively reviewed all coated SEMS placed between October 2008 and September 2015. We analyzed patient-related factors such as the primary underlying disease, prior hepatic procedures, and clinical outcome. We evaluated the location, the number and type of leak (anastomotic or non-anastomotic), and the characteristics of the interventional procedure (number of stents deployed, location of the stents, technical success, and primary functionality). We recorded the complications registered. We studied 14 patients (11 men and 3 women). The mean follow-up period was 375.5 days (range 15-1920 days). Leaks were postsurgical in 12 patients. One patient developed an arteriobilioportal fistula. In another, the biliary leak occurred secondary to the rupture of the common bile duct after ERCP. A total of 23 coated SEMS were placed, including 21 Fluency ® stents (Bard, Tempe, AZ, USA) and 2 Wallflex ® stents (Boston Scientific, Galway, Republic of Ireland). The technical success of the procedure was considered total in 11 (78.6%) patients, partial in 2 (14.3%) patients, and null in 1 (7.2%) patient. The clinical outcome was good in 13 of the 14 patients. The mean period of primary functionality of the coated SEMS was 331 days (range 15-1920 days). No major complications were observed in 11 (78.6%) patients. Percutaneous placement of coated SEMS for the treatment of benign biliary leaks is safe and efficacious, with a high rate of technical and clinical success and a moderate rate of complications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Blind Leak Detection for Closed Systems
NASA Technical Reports Server (NTRS)
Oelgoetz, Peter; Johnson, Ricky; Todd, Douglas; Russell, Samuel; Walker, James
2003-01-01
The current inspection technique for locating interstitial leaking in the Space Shuttle Main Engine nozzles is the application of a liquid leak check solution in the openings where the interstitials space between the tubing and the structural jacket vent out the aft end of the nozzle, while its cooling tubes are pressurized to 25 psig with Helium. When a leak is found, it is classified, and if the leak is severe enough the suspect tube is cut open so that a boroscope can be inserted to find the leak point. Since the boroscope can only cover a finite tube length and since it is impossible to identify which tube (to the right or left of the identified interstitial) is leaking, many extra and undesired repairs have been made to fix just one leak. In certain instances when the interstitials are interlinked by poor braze bonding, many interstitials will show indications of leaking from a single source. What is desired is a technique that can identify the leak source so that a single repair can be performed. Dr, Samuel Russell and James Walker, both with NASA/MSFC have developed a thermographic inspection system that addresses a single repair approach. They have teamed with Boeing/Rocketdyne to repackage the inspection processes to be suitable to address full scale Shuttle development and flight hardware and implement the process at NASA centers. The methods and results presented address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera (capable of detecting a delta temperature difference of 0.025 C) is used to record the cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner hot wall surface as the nozzle is pressurized, These images are enhanced by digitally subtracting a thermal reference image taken before pressurization. The method provides a non-intrusive way of locating the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation. Other applications for this thermographic inspection system are the Reinforced-Carbon-Carbon (RCC) leading edge of the Space Shuttle orbiter and braze joint integrity.
Campos, Guilherme M; Jablons, David; Brown, Lisa M; Ramirez, René M; Rabl, Charlotte; Theodore, Pierre
2010-01-01
Objectives In expert hands, the intra-thoracic esophago-gastric anastamosis usually provides a low rate of strictures and leaks. However, anastomoses can be technically challenging and time consuming when minimally invasive techniques are used. We present our preliminary results of a standardized 25mm/4.8mm circular stapled anastomosis using a trans-orally placed anvil. Materials and Methods We evaluated a prospective cohort of 37 consecutive patients offered minimally invasive Ivor Lewis Esophagectomy at a tertiary referral center. The esophagogastric anastomosis was created using a 25mm anvil (Orvil, Autosuture, Norwalk, CT) passed trans-orally, in a tilted position, and connected to a 90cm long PVC delivery tube through an opening in the esophageal stump. The anastomosis was completed by joining the anvil to a circular stapler (EEA XL 25mm with 4.8mm Staples, Autosuture, Norwalk, CT) inserted into the gastric conduit. Primary outcomes were leak and stricture rates. Results Thirty-seven patients (mean age 65 yrs) with distal esophageal adenocarcinoma (n=29), squamous cell cancer (n=5), or high-grade dysplasia in Barrett's Esophagus (n=3) underwent an Ivor Lewis Esophagectomy between October 2007 and August 2009. The abdominal portion of the operation was completed laparoscopically in 30 patients (81.1%). The thoracic portion was done using a muscle sparing mini-thoracotomy in 23 patients (62.2%) and thoracoscopic techniques in 14 patients (37.8%). There were no intra-operative technical failures of the anastomosis or deaths. Five patients had strictures (13.5%) and all were successfully treated with endoscopic dilations. One patient had an anastomotic leak (2.7%) that was successfully treated by re-operation and endoscopic stenting of the anastomosis. Discussion The circular stapled anastomosis with the transoral anvil allows for an efficient, safe and reproducible anastomosis. This straightforward technique is particularly suited to the completely minimally invasive Ivor Lewis Esophagectomy. PMID:20153660
Code of Federal Regulations, 2010 CFR
2010-07-01
... until the leak check is passed. Post-test leak check ≤4% of average sampling rate After sampling ** See... the test site. The sorbent media must be obtained from a source that can demonstrate the quality...-traceable calibration gas standards and reagents shall be used for the tests and procedures required under...
Experimental study of foam-insulated liquified-gas tanks
NASA Technical Reports Server (NTRS)
Reynolds, Thaine W; Weiss, Solomon
1957-01-01
Experiments with liquid nitrogen and liquid hydrogen is styrofoam-insulated tanks have indicated good agreement between measured and calculated heat-leak rates when the insulation was formed from a single block of material. In a large tank installation where the insulation was applied in sections without sealing the joints, the measured heat leak was about 2 and 1/2 times the calculated value.
... with an artificial valve (this is called the Ross Procedure). This procedure may be useful for people ... valve that does not close all the way will allow blood to leak backwards. This is called ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-04-01
When piping develops leaks, the natural instinct is to shut the process down, purge the lines and call in maintenance crews to make the repairs. There is, however, an alternative: on-the-fly repairs. Through the use of specialized tools, equipment and technicians, shut-off valves can be installed and leaks repaired without interrupting production. The split sleeve offers one of the simpler approaches to on-the-fly repairs. Two half cylinders with inside diameter slightly larger than the outside diameter slightly larger than the outside diameter of the pipe to be repaired are slipped over the latter some distance form the leak and looselymore » bolted together. The cylinder is then slid over the leaking area and the bolts tightened. Gaskets inside the half cylinders provide the needed seal between the pipe and the cylinder. Installing a shut-off valve in an operating pipeline requires much more specialized equipment and skills than does repairing a leak with a split sleeve. A device available from International Piping Services Co. allows a trained crew to isolate a section of pipe, drill out the isolated portion, install a blocking valve and then remove the isolation system--all while continuing to operate the pipeline at temperatures to 700 F and pressures to 700 psi. But Herb Porter, CEO of Ipsco, cautions that unlike the repairing leaks with a split sleeve, installing a blocking valve on-the-fly always demands the services of a highly trained crew.« less
Besselink, Marc G; van Rijssen, L Bengt; Bassi, Claudio; Dervenis, Christos; Montorsi, Marco; Adham, Mustapha; Asbun, Horacio J; Bockhorn, Maximillian; Strobel, Oliver; Büchler, Markus W; Busch, Olivier R; Charnley, Richard M; Conlon, Kevin C; Fernández-Cruz, Laureano; Fingerhut, Abe; Friess, Helmut; Izbicki, Jakob R; Lillemoe, Keith D; Neoptolemos, John P; Sarr, Michael G; Shrikhande, Shailesh V; Sitarz, Robert; Vollmer, Charles M; Yeo, Charles J; Hartwig, Werner; Wolfgang, Christopher L; Gouma, Dirk J
2017-02-01
Recent literature suggests that chyle leak may complicate up to 10% of pancreatic resections. Treatment depends on its severity, which may include chylous ascites. No international consensus definition or grading system of chyle leak currently is available. The International Study Group on Pancreatic Surgery, an international panel of pancreatic surgeons working in well-known, high-volume centers, reviewed the literature and worked together to establish a consensus on the definition and classification of chyle leak after pancreatic operation. Chyle leak was defined as output of milky-colored fluid from a drain, drain site, or wound on or after postoperative day 3, with a triglyceride content ≥110 mg/dL (≥1.2 mmol/L). Three different grades of severity were defined according to the management needed: grade A, no specific intervention other than oral dietary restrictions; grade B, prolongation of hospital stay, nasoenteral nutrition with dietary restriction, total parenteral nutrition, octreotide, maintenance of surgical drains, or placement of new percutaneous drains; and grade C, need for other more invasive in-hospital treatment, intensive care unit admission, or mortality. This classification and grading system for chyle leak after pancreatic resection allows for comparison of outcomes between series. As with the other the International Study Group on Pancreatic Surgery consensus statements, this classification should facilitate communication and evaluation of different approaches to the prevention and treatment of this complication. Copyright © 2016 Elsevier Inc. All rights reserved.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- In the Payload Changeout Room, Launch Pad 39A, workers raise a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, are on a platform in the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, ride a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, are on a platform in the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
Dimitriou, Nikoletta; Panteleimonitis, Sofoklis; Dhillon, Ajit; Boyle, Kirsten; Norwood, Mike; Hemingway, David; Yeung, Justin; Miller, Andrew
2015-12-04
The aims of the study were to determine the radiological leak rate in those patients who had undergone a resection for left-sided colorectal cancer and to see if the presence of a leak can be related with the postoperative clinical period. We also aimed to identify any common factors between patients with leak. A retrospective analysis of prospectively collected data of all patients who underwent a left-sided colorectal cancer resection with formation of a defunctioning ileostomy was undertaken. Between 2005 and 2010, 418 such patients were identified. A water-soluble contrast enema was performed in 339 patients (81.1 %). Of these, 24 (7.1 %) were reported to show an anastomotic leak. Data for these 24 patients is presented in this study. Twenty-three (95.8 %) of the leaks occurred in patients who had undergone an anterior resection; 95.8 % of the patients with a leak were male. Fifteen (62.5 %) patients underwent neo-adjuvant radiation. The mean length of stay in those patients shown to have a subsequent radiological leak was 18.8 days (median), compared with the overall unit figures of 12 days. Only 29.2 % of the patients who had a leak identified had an uncomplicated postoperative period. Overall 87.5 % of the patients had a reversal of the ileostomy. Radiological leakage is not uncommon. The majority of patients, who were shown to have a radiological leak in this study, were male, had undergone an anterior resection, had received neo-adjuvant radiation, had a longer initial length of stay and had postoperative complications. Water-soluble contrast enemas could be selectively used in patients with these characteristics.
Brunelli, Alessandro; Salati, Michele; Pompili, Cecilia; Gentili, Paolo; Sabbatini, Armando
2017-11-01
To verify the association between the air leak objectively measured intraoperatively (IAL) using the ventilator and the air leak duration after pulmonary lobectomy. Prospective analysis on 111 patients submitted to pulmonary lobectomy (33 by video-assisted thoracic surgery). After resection, objective assessment of air leak (in milliliter per minute) was performed before closure of the chest by measuring the difference between a fixed inspired and expired volume, using a tidal volume of 8 ml/kg, a respiratory rate of 10 and a positive-end expiratory pressure of 5 cmH2O. A multivariable analysis was performed for identifying factors associated with duration of postoperative air leak. Average IAL was 158 ml/min (range 0-1500 ml/min). The best cut-off (receiver-operating characteristics analysis) associated with air leak longer than 5 days was 500 ml/min. Nine patients had IAL >500 ml/min (8%). They had a longer duration of postoperative air leak compared with those with a lower IAL (mean values, 10.1 days, SD 8.8 vs 1.5 days, SD 4.9 P < 0.001). The following variables remained associated with days of air leak duration after multivariable regression: left side resection (P = 0.018), upper site resection (P = 0.031) and IAL >500 ml/min (P < 0.001). The following equation estimating the days of air leak duration was generated: 1.7 + 2.4 × left side + 2.2 × upper site + 8.8 × IAL >500. The air leak measurement using the ventilator parameters after lung resection may assist in estimating the risk of postoperative prolonged air leak. An IAL > 500 ml/min may warrant the use of intraoperative preventative measures, particularly after video-assisted thoracic surgery lobectomy where a submersion test is often unreliable. © 2017 European Society of Cardiology and European Atherosclerosis Association. All rights reserved. For permissions please email: journals.permissions@oup.com.
Gas Leak Detection by Dilution of Atmospheric Oxygen
Lambrecht, Armin; Maier, Eric; Strahl, Thomas; Herbst, Johannes
2017-01-01
Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2. PMID:29206133
Gelbmann, C M; Ratiu, N L; Rath, H C; Rogler, G; Lock, G; Schölmerich, J; Kullmann, F
2004-08-01
Extensive anastomotic leaks after esophageal resection and esophageal perforations are a therapeutic challenge. The aim of the present study was to assess the potential of the self-expandable Polyflex plastic stent for the treatment of these conditions. Between January 2002 and March 2003, nine patients were treated with a self-expandable Polyflex plastic stent for sealing of thoracic esophagoenteric anastomotic leaks following surgical resection (n = 5) or esophageal perforation (n = 4). In all patients the stents were inserted successfully without technical problems. In all but two patients complete sealing of the leak was achieved as demonstrated by radiography with water-soluble contrast media. The stent migration rate was 30 % and repositioning of the migrated stents was possible in all cases. Complete mucosal healing of the esophageal leaks and stent extraction was achieved in six patients. The stents were in situ for an average period of 135 +/- 78 days. Two critically ill patients with anastomotic leaks died in spite of stent insertion due to sepsis and one patient with esophageal perforation died due to the underlying malignant disease. Our preliminary experience with the self-expanding and removable Polyflex plastic stent for the sealing of anastomotic leaks and esophageal perforations suggests that this stent is a feasible treatment option, in particular, for more extensive esophageal defects, patients with co-morbid conditions, and critically ill patients.
Filippidis, Aristotelis S; Kalani, M Yashar S; Nakaji, Peter; Rekate, Harold L
2011-11-01
Negative-pressure and low-pressure hydrocephalus are rare clinical entities that are frequently misdiagnosed. They are characterized by recurrent episodes of shunt failure because the intracranial pressure is lower than the opening pressure of the valve. In this report the authors discuss iatrogenic CSF leaks as a cause of low- or negative-pressure hydrocephalus after approaches to the cranial base. The authors retrospectively reviewed cases of low-pressure or negative-pressure hydrocephalus presenting after cranial approaches complicated with a CSF leak at their institution. Three patients were identified. Symptoms of high intracranial pressure and ventriculomegaly were present, although the measured pressures were low or negative. A blocked communication between the ventricles and the subarachnoid space was documented in 2 of the cases and presumed in the third. Shunt revisions failed repeatedly. In all cases, temporary clinical and radiographic improvement resulted from external ventricular drainage at subatmospheric pressures. The CSF leaks were sealed and CSF communication was reestablished operatively. In 1 case, neck wrapping was used with temporary success. Negative-pressure or low-pressure hydrocephalus associated with CSF leaks, especially after cranial base approaches, is difficult to treat. The solution often requires the utilization of subatmospheric external ventricular drains to establish a lower ventricular drainage pressure than the drainage pressure created in the subarachnoid space, where the pressure is artificially lowered by the CSF leak. Treatment involves correction of the CSF leak, neck wrapping to increase brain turgor and allow the pressure in the ventricles to rise to the level of the opening pressure of the valve, and reestablishing the CSF route.
The Soil Microbial Response to a Massive Natural Gas Leak
NASA Astrophysics Data System (ADS)
Tavormina, P. L.; Newman, S.; Shen, L.; Connon, S. A.; Okumura, M.; Orphan, V. J.
2016-12-01
The 2015/2016 gas leak in the Porter Ranch community (Southern California) was the largest natural gas leak in US history. While considerable attention has focused on the amount of methane released to the atmosphere and the effects of other gas components on human well-being, less attention has been given to the response of soil microbes to this event. These microbes represent natural pathways for utilization of C1 compounds in soils and, possibly, untapped potential to remediate natural and anthropogenic gas emissions. We monitored onsite and background soil methane concentrations and microbial communities during and following the Porter Ranch gas leak. Soil core samples (25cm depth, collected twice monthly beginning in January 2016) were preserved for DNA, RNA, microscopic, stable isotope probing, and chromatographic methods. Simultaneously to coring, gas from soil pore spaces was collected for cavity ringdown spectroscopy to measure carbon dioxide, methane and ethane concentrations, and estimate corresponding isotopic values in carbon dioxide and methane. By pairing these measurements with high throughput sequencing, transcript analysis, and cultivation, we demonstrate discrete shifts in the total microbial community in surface (0 - 5 cm) and deep (20 - 25 cm) soils. Importantly, we find that methane consumption likely occurred in surface soils during and following the leak. The lineages most significantly correlated with elevated methane from the leak event were five orders of magnitude more abundant near the leak event in space and time, indicating a microbial bloom. These lineages are previously unrecognized members of Sphingomonadaceae, and they encode at least two biochemical pathways for methane oxidation. Cultivation of the first representative of this group now allows more detailed investigation into its capacity for microbially-mediated soil methane oxidation and mitigation.
NASA Astrophysics Data System (ADS)
Williams, David J.; Wadsworth, Winthrop; Salvaggio, Carl; Messinger, David W.
2006-08-01
Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality and present a loss of product for industry. Surveying a facility for potential gas leaks can be a daunting task. Industrial leak detection and repair programs can be expensive to administer. An efficient, accurate and cost effective method for detecting and quantifying gas leaks would both save industries money by identifying production losses and improve regional air quality. Specialized thermal video systems have proven effective in rapidly locating gas leaks. These systems, however, do not have the spectral resolution for compound identification. Passive FTIR spectrometers can be used for gas compound identification, but using these systems for facility surveys is problematic due to their small field of view. A hybrid approach has been developed that utilizes the thermal video system to locate gas plumes using real time visualization of the leaks, coupled with the high spectral resolution FTIR spectrometer for compound identification and quantification. The prototype hybrid video/spectrometer system uses a sterling cooled thermal camera, operating in the MWIR (3-5 μm) with an additional notch filter set at around 3.4 μm, which allows for the visualization of gas compounds that absorb in this narrow spectral range, such as alkane hydrocarbons. This camera is positioned alongside of a portable, high speed passive FTIR spectrometer, which has a spectral range of 2 - 25 μm and operates at 4 cm -1 resolution. This system uses a 10 cm telescope foreoptic with an onboard blackbody for calibration. The two units are optically aligned using a turning mirror on the spectrometer's telescope with the video camera's output.
Hydrophobic, Porous Battery Boxes
NASA Technical Reports Server (NTRS)
Bragg, Bobby J.; Casey, John E., Jr.
1995-01-01
Boxes made of porous, hydrophobic polymers developed to contain aqueous potassium hydroxide electrolyte solutions of zinc/air batteries while allowing air to diffuse in as needed for operation. Used on other types of batteries for in-cabin use in which electrolytes aqueous and from which gases generated during operation must be vented without allowing electrolytes to leak out.
2014-01-01
Background We considered of interest to evaluate how aging affects mitochondrial function in skeletal muscle. Methods We measured mitochondrial oxidative capacity and proton leak, together with lipid oxidative damage, superoxide dismutase specific activity and uncoupling protein 3 content, in subsarcolemmal and intermyofibrillar mitochondria from adult (six months) and old (two years) rats. Body composition, resting metabolic rate and plasma non esterified fatty acid levels were also assessed. Results Old rats displayed significantly higher body energy and lipids, while body proteins were significantly lower, compared to adult rats. In addition, plasma non esterified fatty acid levels were significantly higher, while resting metabolic rates were found to be significantly lower, in old rats compared to adult ones. Significantly lower oxidative capacities in whole tissue homogenates and in intermyofibrillar and subsarcolemmal mitochondria were found in old rats compared to adult ones. Subsarcolemmal and intermyofibrillar mitochondria from old rats exhibited a significantly lower proton leak rate, while oxidative damage was found to be significantly higher only in subsarcolemmal mitochondria. Mitochondrial superoxide dismutase specific activity was not significantly affected in old rats, while significantly higher content of uncoupling protein 3 was found in both mitochondrial populations from old rats compared to adult ones, although the magnitude of the increase was lower in subsarcolemmal than in intermyofibrillar mitochondria. Conclusions The decrease in oxidative capacity and proton leak in intermyofibrillar and subsarcolemmal mitochondria could induce a decline in energy expenditure and thus contribute to the reduced resting metabolic rate found in old rats, while oxidative damage is present only in subsarcolemmal mitochondria. PMID:24950599
Gray, Harold E.; McLaurin, Felder M.; Ortiz, Monico; Huth, William A.
1996-01-01
A device or system for monitoring for the presence of leaks from a hazardous fluid is disclosed which uses two electrodes immersed in deionized water. A gas is passed through an enclosed space in which a hazardous fluid is contained. Any fumes, vapors, etc. escaping from the containment of the hazardous fluid in the enclosed space are entrained in the gas passing through the enclosed space and transported to a closed vessel containing deionized water and two electrodes partially immersed in the deionized water. The electrodes are connected in series with a power source and a signal, whereby when a sufficient number of ions enter the water from the gas being bubbled through it (indicative of a leak), the water will begin to conduct, thereby allowing current to flow through the water from one electrode to the other electrode to complete the circuit and activate the signal.
DUMAND-II (deep underwater muon and neutrino detector) progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, K.K.; The DUMAND Collaboration
1995-07-10
The DUMAND II detector will search for astronomical sources of high energy neutrinos. Successful deployment of the basic infrastructure, including the shore cable, the underwater junction box, and an environmental module was accomplished in December, 1993. One optical module string was also deployed and operated, logging data for about 10 hours. The underwater cable was connected to the shore station where we were able to successfully exercise system controls and log further environmental data. After this time, water leaking into the electronics control module for the deployed string disabled the string electrical system. The acquired data are consistent with themore » expected rate of downgoing muons, and our ability to reconstruct muons was demonstrated. The measured acoustical backgrounds are consistent with expectation, which should allow acoustical detection of nearby PeV particle cascades. The disabled string has been recovered and is undergoing repairs ashore. We have identified the source of the water leak and implemented additional testing and QC procedures to ensure no repetition in our next deployment. We will be ready to deploy three strings and begin continuous data taking in late 1994 or early 1995. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.« less
NASA Astrophysics Data System (ADS)
Hastings, Leon J.; Martin, James J.
1998-01-01
An 18-m3 system-level test bed termed the Multipurpose Hydrogen Test Bed (MHTB has been used to evaluate a foam/multilayer combination insulation concept. The foam element (Isofoam SS-1171) protects against ground hold/ascent flight environments, and allows the use of dry nitrogen purge as opposed to a more complex/heavy helium purge subsystem. The MLI (45 layers of Double Aluminized Mylar with Dacron spacers) is designed for an on-orbit storage period of 45 days. Unique MLI features included; a variable layer density (reduces weight and radiation losses), larger but fewer DAM vent perforations (reduces radiation losses), and a roll wrap installation which resulted in a very robust MLI and reduced both assembly man-hours and seam heat leak. Ground hold testing resulted in an average heat leak of 63 W/m2 and purge gas liquefaction was successfully prevented. The orbit hold simulation produced a heat leak of 0.22 W/m2 with 305 K boundary which, compared to historical data, represents a 50-percent heat leak reduction.
Schlieren optics for leak detection
NASA Technical Reports Server (NTRS)
Peale, Robert E.; Ruffin, Alranzo B.
1995-01-01
The purpose of this research was to develop an optical method of leak detection. Various modifications of schlieren optics were explored with initial emphasis on leak detection of the plumbing within the orbital maneuvering system of the space shuttle (OMS pod). The schlieren scheme envisioned for OMS pod leak detection was that of a high contrast pattern on flexible reflecting material imaged onto a negative of the same pattern. We find that the OMS pod geometry constrains the characteristic length scale of the pattern to the order of 0.001 inch. Our experiments suggest that optical modulation transfer efficiency will be very low for such patterns, which will limit the sensitivity of the technique. Optical elements which allow a negative of the scene to be reversibly recorded using light from the scene itself were explored for their potential in adaptive single-ended schlieren systems. Elements studied include photochromic glass, bacteriorhodopsin, and a transmissive liquid crystal display. The dynamics of writing and reading patterns were studied using intensity profiles from recorded images. Schlieren detection of index gradients in air was demonstrated.
A non-equilibrium thermodynamics model of reconstituted Ca(2+)-ATPase.
Waldeck, A R; van Dam, K; Berden, J; Kuchel, P W
1998-01-01
A non-equilibrium thermodynamics (NET) model describing the action of completely coupled or 'slipping' reconstituted Ca(2+)-ATPase is presented. Variation of the coupling stoichiometries with the magnitude of the electrochemical gradients, as the ATPase hydrolyzes ATP, is an indication of molecular slip. However, the Ca2+ and H+ membrane-leak conductances may also be a function of their respective gradients. Such non-ohmic leak typically yields 'flow-force' relationships that are similar to those that are obtained when the pump slips; hence, caution needs to be exercised when interpreting data of Ca(2+)-ATPase-mediated fluxes that display a non-linear dependence on the electrochemical proton (delta mu H) and/or calcium gradients (delta mu Ca). To address this issue, three experimentally verifiable relationships differentiating between membrane leak and enzymic slip were derived. First, by measuring delta mu H as a function of the rate of ATP hydrolysis by the enzyme. Second, by measuring the overall 'efficiency' of the pump as a function of delta mu H. Third, by measuring the proton ejection rate by the pump as a function of its ATP hydrolysis rate.
NASA Astrophysics Data System (ADS)
Englander, J. G.; Brandt, A. R.; Jackson, R. B.; Alvarez, R.; Lyon, D. R.
2016-12-01
A recent study used helicopters and optical gas imaging (infrared-based) to study hydrocarbon leaks [1] across numerous oil and gas producing basins. The appearance of leaks appeared to have small statistical correlations with factors such as age of wells, production rate, or water production. However, there have not been few if any attempts to observe the presence of leaks over time. In this work, we used the same helicopter-based optical gas imaging techniques to revisit wells in the Bakken formation that had previously been measured in 2014 [1] In this study, we visited 353 of the total 683 well pads in Bakken from the original study, and we also visited 50 randomly selected well pads that were newly developed between studies. We first examine the presence of leaks as a function of different factors, including: operator, number of wells, tanks, and treaters on a well pad; and numerous other possible emissions drivers. In addition, using the previous years observations as our prior, we conducted a Bayesian analysis to determine the likelihood of finding a leaking or non-leaking well pad and compared the observations to a Monte Carlo simulation of randomly distributed leaks. We find that the overall prevalence of observed emissions was similar for each year (11% for 2014 observations and 10% for 2015 observations). We also find whether a pad was found to be leaking in the first observation year had a statistically significant influence (4.9σ) on the presence of a leak in the following observation year. Similar levels of persistence are also apparent for non-leaking well pads. [1] D. R. Lyon, R. A. Alvarez, D. Zavala-Araiza, A. R. Brandt, R. B. Jackson, and S. P. Hamburg, "Aerial surveys of elevated hydrocarbon emissions from oil and gas production sites," Environ. Sci. Technol., p. acs.est.6b00705, Apr. 2016.
Rapid Surface Detection of CO2 Leaks from Geologic Sequestration Sites
NASA Astrophysics Data System (ADS)
Moriarty, D. M.; Krevor, S. C.; Benson, S. M.
2013-12-01
Carbon sequestration is becoming a viable option for global CO2 mitigation but effective monitoring methods are needed assure the carbon dioxide stays underground. Above surface monitoring using a mobile gas analyzer is one such method (e.g. Krevor et al., 2010). The Picarro gas analyzer uses wavelength-scanned cavity ring down spectroscopy to accurately identify concentrations of various atmospheric gases including their isotopic composition. These measurements can then be used for anomaly (leak) detection and source attribution. Leaks are detected by anomalous absolute concentration of CO2 and anomalous δ13C values. Source attribution is determined by the isotopic concentrations of the identified leaking gas. To distinguish between noise from ambient signals and leaks, a method based on mixing ratios has been developed. A newly acquired data set presented here has been collected from a 3.7km2 area with naturally occurring CO2 springs near Green River, Utah. All of the areas of known leakage were readily detected using this method along with several other areas that showed significant signs of leakage. In addition, testing on the Stanford campus has shown that this method is sensitive enough to distinguish between open fields and roadways. Another data set is being collected at Montana State University at the ZERT monitoring test site where an artificial leak has been created for the purpose of testing leak detection and quantification methods. Data collected from this site are being used for (1) assessing of detection levels and how they depend on environmental parameters such as wind speed, and acquisition variables such as sample rate and traverse speed, (2) optimizing acquisition parameters to increase detection levels and increase confidence in leak detection, (3) evaluating the potential for quantifying the magnitude of the leak and (4) spatial data analysis to identify the most probable leak locations.
Aryaie, Amir H; Singer, Jordan L; Fayezizadeh, Mojtaba; Lash, Jon; Marks, Jeffrey M
2017-02-01
Anastomotic or staple-line leak after foregut surgery presents a formidable management challenge. In recent years, with advancement of endoscopy, self-expanding covered stents have been gaining popularity. In this study, we aimed to determine the safety and effectiveness of self-expanding covered stents in management of leak after foregut surgery. Consecutive patients who received a fully covered self-expandable metal stent (SEMS) due to an anastomotic leak after upper gastrointestinal surgery between 2009 and 2014 were retrospectively reviewed. Demographic data, stent placement and removal, clinical success, time to resolution, and complications were collected. Predictive factors for clinical success rate were assessed. A total of 20 consecutive patients underwent placement of fully covered SEMS for anastomotic leak, following esophagectomy (n = 5), esophageal diverticulectomy (n = 1), gastric sleeve (n = 4), gastric bypass (n = 3), partial gastrectomy (n = 4), and total gastrectomy (n = 3). All the stents were removed successfully, and clinical resolution was achieved in 18 patients (90 %) after a median of two (range 1-3) procedures and a mean of 6.2 weeks (range 0.4-14). Complications presented in 12 patients (60 %), including stent migration (n = 8), mucosal friability (n = 4), tissue integration (n = 2), and bleeding (n = 2). Two (10 %) patients' treatment was complicated by aorto-esophageal fistula formation resulting in one death. Demographic factors, comorbidities, and type of surgery were not predictive of clinical success rate or time to resolution. SEMS are effective tools for the management of leaks after foregut surgery. The biggest challenge with this approach is stent migration. Caution is warranted due to the risk of fatal complications such as aorto-esophageal fistula formation. No type of surgery or particular patient factor, including age, sex, BMI, albumin, history of radiation, malignancy, and comorbid diabetes or coronary artery disease, appeared to be correlated with success rate. Larger studies are needed to determine factors predictive of clinical success.
β-Adrenergic induced SR Ca2+ leak is mediated by an Epac-NOS pathway.
Pereira, Laëtitia; Bare, Dan J; Galice, Samuel; Shannon, Thomas R; Bers, Donald M
2017-07-01
Cardiac β-adrenergic receptors (β-AR) and Ca 2+ -Calmodulin dependent protein kinase (CaMKII) regulate both physiological and pathophysiological Ca 2+ signaling. Elevated diastolic Ca 2+ leak from the sarcoplasmic reticulum (SR) contributes to contractile dysfunction in heart failure and to arrhythmogenesis. β-AR activation is known to increase SR Ca 2+ leak via CaMKII-dependent phosphorylation of the ryanodine receptor. Two independent and reportedly parallel pathways have been implicated in this β-AR-CaMKII cascade, one involving exchange protein directly activated by cAMP (Epac2) and another involving nitric oxide synthase 1 (NOS1). Here we tested whether Epac and NOS function in a single series pathway to increase β-AR induced and CaMKII-dependent SR Ca 2+ leak. Leak was measured as both Ca 2+ spark frequency and tetracaine-induced shifts in SR Ca 2+ , in mouse and rabbit ventricular myocytes. Direct Epac activation by 8-CPT (8-(4-chlorophenylthio)-2'-O-methyl-cAMP) mimicked β-AR-induced SR Ca 2+ leak, and both were blocked by NOS inhibition. The same was true for myocyte CaMKII activation (assessed via a FRET-based reporter) and ryanodine receptor phosphorylation. Inhibitor and phosphorylation studies also implicated phosphoinositide 3-kinase (PI3K) and protein kinase B (Akt) downstream of Epac and above NOS activation in this pathway. We conclude that these two independently characterized parallel pathways function mainly via a single series arrangement (β-AR-cAMP-Epac-PI3K-Akt-NOS1-CaMKII) to mediate increased SR Ca 2+ leak. Thus, for β-AR activation the cAMP-PKA branch effects inotropy and lusitropy (by effects on Ca 2+ current and SR Ca 2+ -ATPase), this cAMP-Epac-NOS pathway increases pathological diastolic SR Ca 2+ leak. This pathway distinction may allow novel SR Ca 2+ leak therapeutic targeting in treatment of arrhythmias in heart failure that spare the inotropic and lusitropic effects of the PKA branch. Copyright © 2017 Elsevier Ltd. All rights reserved.
Diana, Michele; Usmaan, Hameed; Legnèr, Andras; Yu-Yin, Liu; D'Urso, Antonio; Halvax, Peter; Nagao, Yoshihiro; Pessaux, Patrick; Marescaux, Jacques
2016-07-01
Bile leakage is a serious complication occurring in up to 10 % of hepatic resections. Intraoperative detection of bile leakage is challenging, and concomitant blood oozing can mask the presence of bile. Intraductal dye injection [methylene blue or indocyanine green (ICG)] is a validated technique to detect bile leakage. However, this method is time-consuming, particularly in the laparoscopic setting. A novel narrow band imaging (NBI) modality (SPECTRA-A; Karl Storz, Tuttlingen, Germany) allows easy discrimination of the presence of bile, which appears in clear orange, by image processing. The aim of this experimental study was to evaluate SPECTRA-A ability to detect bile leakage. Twelve laparoscopic partial hepatectomies were performed in seven pigs. The common bile duct was clipped distally and dissected, and a catheter was inserted and secured with a suture or a clip. Liver dissection was achieved with an ultrasonic cutting device. Dissection surfaces were checked by frequently switching on the SPECTRA filter to identify the presence of bile leakage. Intraductal ICG injection through the catheter was performed to confirm SPECTRA findings. Three active bile leakages were obtained out of 12 hepatectomies and successfully detected intraoperatively by the SPECTRA. There was complete concordance between NBI and ICG fluorescence detection. No active leaks were found in the remaining cases with both techniques. The leaking area identified was sutured, and SPECTRA was used to assess the success of the repair. The SPECTRA laparoscopic image processing system allows for rapid detection of bile leaks following hepatectomy without any contrast injection.
Neonatal hygroscopic condenser humidifier.
Gedeon, A; Mebius, C; Palmer, K
1987-01-01
A hygroscopic condenser humidifier was developed for neonates on mechanical ventilation and was evaluated by laboratory tests and clinically. Humidification provided by the unit was measured in the 10- to 50-ml tidal-volume range at ambient temperatures of 24 degrees C and 38 degrees C. The effect of a leaking patient connection on device performance was investigated. Leakage rates were measured routinely in a neonatal ICU and surgery to determine the clinical significance. In the entire tidal volume and temperature range, the unit provided an inspiratory water content in excess of 30 g/m3 when the leak fraction (volume leaked/volume delivered at Y-piece) was less than 15%. This was found in three out of four cases. In about one out of ten cases, the leak exceeded 30%, which invariably led to corrective action, such as repositioning or changing the endotracheal tube. However, even at a 30% leak, a water content of about 26 g/m3 was still available for humidifying the inspired gas, which corresponds to normal physiologic conditions found in the trachea for nasal breathing of room air.
Levine, Zachary H.; Pintar, Adam L.; Dobler, Jeremy T.; ...
2016-04-13
Laser absorption spectroscopy (LAS) has been used over the last several decades for the measurement of trace gasses in the atmosphere. For over a decade, LAS measurements from multiple sources and tens of retroreflectors have been combined with sparse-sample tomography methods to estimate the 2-D distribution of trace gas concentrations and underlying fluxes from point-like sources. In this work, we consider the ability of such a system to detect and estimate the position and rate of a single point leak which may arise as a failure mode for carbon dioxide storage. The leak is assumed to be at a constant ratemore » giving rise to a plume with a concentration and distribution that depend on the wind velocity. Lastly, we demonstrate the ability of our approach to detect a leak using numerical simulation and also present a preliminary measurement.« less
NASA Technical Reports Server (NTRS)
Hass, Neal; Mizukami, Masashi; Neal, Bradford A.; St. John, Clinton; Beil, Robert J.; Griffin, Timothy P.
1999-01-01
This paper presents pertinent results and assessment of propellant feed system leak detection as applied to the Linear Aerospike SR-71 Experiment (LASRE) program flown at the NASA Dryden Flight Research Center, Edwards, California. The LASRE was a flight test of an aerospike rocket engine using liquid oxygen and high-pressure gaseous hydrogen as propellants. The flight safety of the crew and the experiment demanded proven technologies and techniques that could detect leaks and assess the integrity of hazardous propellant feed systems. Point source detection and systematic detection were used. Point source detection was adequate for catching gross leakage from components of the propellant feed systems, but insufficient for clearing LASRE to levels of acceptability. Systematic detection, which used high-resolution instrumentation to evaluate the health of the system within a closed volume, provided a better means for assessing leak hazards. Oxygen sensors detected a leak rate of approximately 0.04 cubic inches per second of liquid oxygen. Pressure sensor data revealed speculated cryogenic boiloff through the fittings of the oxygen system, but location of the source(s) was indeterminable. Ultimately, LASRE was cancelled because leak detection techniques were unable to verify that oxygen levels could be maintained below flammability limits.
NASA Astrophysics Data System (ADS)
Ebadighajari, Alireza; DeVaal, Jake; Golnaraghi, Farid
2017-02-01
Formation of membrane pinholes is a common defect in fuel cells, inflicting more cost and making less durable cells. This work focuses on mitigating this issue, and offers a continuous online treatment instead of attempting to dynamically model the hydrogen transfer leak rate. This is achieved by controlling the differential pressure between the anode and cathode compartments at the inlet side of the fuel cell stack, known as the fuel overpressure. The model predictive control approach is used to attain the objectives in a Ballard 9-cell Mk1100 polymer electrolyte membrane fuel cell (PEMFC) with inclusion of hydrogen transfer leak. Furthermore, the pneumatic modeling technique is used to model the entire anode side of a fuel cell station. The hydrogen transfer leak is embedded in the model in a novel way, and is considered as a disturbance during the controller design. Experimental results for different sizes of hydrogen transfer leaks are provided to show the benefits of fuel overpressure control system in alleviating the effects of membrane pinholes, which in turn increases membrane longevity, and reduces hydrogen emissions in the eventual presence of transfer leaks. Moreover, the model predictive controller provides an optimal control input while satisfying the problem constraints.
Operational Philosophy Concerning Manned Spacecraft Cabin Leaks
NASA Technical Reports Server (NTRS)
DeSimpelaere, Edward
2011-01-01
The last thirty years have seen the Space Shuttle as the prime United States spacecraft for manned spaceflight missions. Many lessons have been learned about spacecraft design and operation throughout these years. Over the next few decades, a large increase of manned spaceflight in the commercial sector is expected. This will result in the exposure of commercial crews and passengers to many of the same risks crews of the Space Shuttle have encountered. One of the more dire situations that can be encountered is the loss of pressure in the habitable volume of the spacecraft during on orbit operations. This is referred to as a cabin leak. This paper seeks to establish a general cabin leak response philosophy with the intent of educating future spacecraft designers and operators. After establishing a relative definition for a cabin leak, the paper covers general descriptions of detection equipment, detection methods, and general operational methods for management of a cabin leak. Subsequently, all these items are addressed from the perspective of the Space Shuttle Program, as this will be of the most value to future spacecraft due to similar operating profiles. Emphasis here is placed upon why and how these methods and philosophies have evolved to meet the Space Shuttle s needs. This includes the core ideas of: considerations of maintaining higher cabin pressures vs. lower cabin pressures, the pros and cons of a system designed to feed the leak with gas from pressurized tanks vs. using pressure suits to protect against lower cabin pressures, timeline and consumables constraints, re-entry considerations with leaks of unknown origin, and the impact the International Space Station (ISS) has had to the standard Space Shuttle cabin leak response philosophy. This last item in itself includes: procedural management differences, hardware considerations, additional capabilities due to the presence of the ISS and its resource, and ISS docking/undocking considerations with a cabin leak occurring. The paper also offers a look at how different equipment configurations on future spacecraft impact the previously defined cabin leak operational philosophy and includes additional operational methods and considerations that result due to various configurations. The intent is to showcase these various considerations and highlight the variability they allow. The paper concludes with a selection of the author s personal observations from a spacecraft operator's point of view and recommendations with the goal of improving the design and operations of future spacecraft.
Field Observations of Methane Emissions from Unconventional and Conventional Fossil Fuel Exploration
NASA Astrophysics Data System (ADS)
Dubey, M.; Lindenmaier, R.; Arata, C.; Costigan, K. R.; Frankenberg, C.; Kort, E. A.; Rahn, T. A.; Henderson, B. G.; Love, S. P.; Aubrey, A. D.
2013-12-01
Energy from methane (CH4) has lower carbon dioxide and air pollutant emissions per unit energy produced than coal or oil making it a desirable fossil fuel. Hydraulic fracturing is allowing United States to harvest the nation's abundant domestic shale gas reservoirs to achieve energy independence. However, CH4 is a gas that is hard to contain during mining, processing, transport and end-use. Therefore fugitive CH4 leaks occur that are reported in bottom up inventories by the EPA. Recent targeted field observations at selected plays have provided top down CH4 leak estimates that are larger than the reported EPA inventories. Furthermore, no long-term regional baselines are available to delineate leaks from unconventional mining operations from historical conventional mining. We will report and compare observations of fugitive CH4 leaks from conventional and unconventional mining to understand changes from technology shifts. We will report in situ and regional column measurements of CH4, its isotopologue 13CH4 and ethane (C2H6) at our Four Corners site near Farmington, NM. The region has substantial coal bed methane, conventional oil and gas production, processing and distribution with minimal hydraulic fracturing activity. We observe large enhancements in in situ and regional column CH4 with distinct time dependence. Our in situ 13CH4 observations and remote C2H6/CH4 provide strong evidence of thermogenic sources. Comparisons of WRF-simulations with emissions inventory (Edgar) with our observations show that the fugitive CH4 leaks from conventional mining are 3 times greater than reported. We also compare in situ mobile surveys of fugitive CH4 and 13CH4 leak signals in basins with conventional (San Juan) mining and unconventional (Permian and Powder River) mining. A large number of active and closed wells were sampled in these regions. Furthermore, play scale surveys on public roads allowed us to gain a regional perspective. The composition of atmospheric 13CH4 observed in the Powder River basin was lighter than the Permian and San Juan basins indicating a higher microbial generated fraction. More extensive and larger CH4 enhancements were measured in the Permian basin that could be a result of the large expansion of unconventional oil and gas production in this region. However, there are variations amongst wells and plays suggesting that operator practices and reservoir formation play a role in determining the fugitive leaks.
Anegg, Udo; Lindenmann, Jorg; Matzi, Veronika; Mujkic, Dzenana; Maier, Alfred; Fritz, Lukas; Smolle-Jüttner, Freyja Maria
2006-06-01
Prolonged air leak after pulmonary resection is a common complication and a major limiting factor for early discharge from hospital. Currently there is little consensus on its management. The aim of this study was to develop and evaluate a measuring device which allows a simple digital bed-side quantification of air-leaks compatible to standard thoracic drainage systems. The measuring device (AIRFIX) is based upon a 'mass airflow' sensor with a specially designed software package that is connected to a thoracic suction drainage system. Its efficacy in detecting pulmonary air-leaks was evaluated in a series of 204 patients; all postoperative measurements were done under standardized conditions; the patients were asked to cough, to take a deep breath, to breathe out against the resistance of a flutter valve, to keep breath and to breathe normally. As standard parameters, the leakage per breath or cough (ml/b) as well as the leakage per minute (ml/min) were displayed and recorded on the computer. Air-leaks within a range of 0.25-45 ml/b and 5-900 ml/min were found. Removal of the chest tubes was done when leakage volume on Heimlich valve was less than 1.0 ml/b or 20 ml/min. After drain removal based upon the data from chest tube airflowmetry none of the patients needed re-drainage due to pneumothorax. The AIRFIX device for bed-side quantification of air-leaks has proved to be very simple and helpful in diagnosis and management of air-leaks after lung surgery, permitting drain removal without tentative clamping.
Mitchell, Bartley D; Verla, Terence; Reddy, Duemani; Winnegan, Lona; Omeis, Ibrahim
2016-04-01
Cerebrospinal fluid (CSF) leak during anterior cervical spine surgery can lead to complications, including wound breakdown, meningitis, headaches, need for lumbar drain, or additional surgery. These leaks can be difficult to manage given the limited field of view and lack of deep access. Herein, we describe 8 consecutive patients who underwent intraoperative repair of CSF leak, with no postoperative evidence of wound dehiscence or drainage. A retrospective review was performed on 8 cases where CSF leak was encountered during an anterior cervical spine surgery. Patients had ossification of the posterior longitudinal ligament, intradural disk herniation, or dural ectasia. Intraoperative repair was as follows. First, CSF was drained to low pressure, and durotomy was covered by dural substitute and sealant agent. Then the interbody graft used was manually undersized in the anteroposterior dimension to allow for expansion of the agents used. Anterior instrumentation was then performed. Finally, a wound drain was anchored to a biologic bag for shoulder level passive drainage. In all 8 cases, there were no cases of wound dehiscence or CSF leak using this strategy. Likewise, there was no evidence of cord compression or neurologic deficits. No meningitis or persistent headaches were reported, and there was no need for lumbar drain placement at any time postoperatively. Once durotomy is encountered during anterior spine surgery, draining the CSF to a low pressure followed by dural substitute with a sealing agent, followed by a smaller anteroposterior size graft is an effective strategy of preventing complications in an inescapable problem. Copyright © 2016 Elsevier Inc. All rights reserved.
Hydrogen Sensors Boost Hybrids; Today's Models Losing Gas?
NASA Technical Reports Server (NTRS)
2005-01-01
Advanced chemical sensors are used in aeronautic and space applications to provide safety monitoring, emission monitoring, and fire detection. In order to fully do their jobs, these sensors must be able to operate in a range of environments. NASA has developed sensor technologies addressing these needs with the intent of improving safety, optimizing combustion efficiencies, and controlling emissions. On the ground, the chemical sensors were developed by NASA engineers to detect potential hydrogen leaks during Space Shuttle launch operations. The Space Shuttle uses a combination of hydrogen and oxygen as fuel for its main engines. Liquid hydrogen is pumped to the external tank from a storage tank located several hundred feet away. Any hydrogen leak could potentially result in a hydrogen fire, which is invisible to the naked eye. It is important to detect the presence of a hydrogen fire in order to prevent a major accident. In the air, the same hydrogen-leak dangers are present. Stress and temperature changes can cause tiny cracks or holes to form in the tubes that line the Space Shuttle s main engine nozzle. Such defects could allow the hydrogen that is pumped through the nozzle during firing to escape. Responding to the challenges associated with pinpointing hydrogen leaks, NASA endeavored to improve propellant leak-detection capabilities during assembly, pre-launch operations, and flight. The objective was to reduce the operational cost of assembling and maintaining hydrogen delivery systems with automated detection systems. In particular, efforts have been focused on developing an automated hydrogen leak-detection system using multiple, networked hydrogen sensors that are operable in harsh conditions.
Tamura, Ryota; Tomio, Ryosuke; Mohammad, Farrag; Toda, Masahiro; Yoshida, Kazunari
2018-03-16
OBJECTIVE The anterior transpetrosal approach (ATPA) was established in 1984 and has been particularly effective for petroclival tumors. Although some complications associated with this approach, such as venous hemorrhage in the temporal lobe and nervous disturbances, have been resolved over the years, the incidence rate of CSF leaks has not greatly improved. In this study, some varieties of air cell tracts that are strongly related to CSF leaks are demonstrated. In addition, other pre- and postoperative risk factors for CSF leakage after ATPA are discussed. METHODS Preoperative and postoperative target imaging of the temporal bone was performed in a total of 117 patients who underwent ATPA, and various surgery-related parameters were analyzed. RESULTS The existence of air cells at the petrous apex, as well as fluid collection in the mastoid antrum detected by a postoperative CT scan, were possible risk factors for CSF leakage. Tracts that directly connected to the antrum from the squamous part of the temporal bone and petrous apex, rather than through numerous air cells, were significantly related to CSF leak and were defined as "direct tract." All patients with a refractory CSF leak possessed "unusual tracts" that connected to the attic, tympanic cavity, or eustachian tube, rather than through the mastoid antrum. CONCLUSIONS Preoperative assessment of petrous pneumatization types is necessary to prevent CSF leaks. Direct and unusual tracts are particularly strong risk factors for CSF leaks.
Posttransplant complications in adult recipients of intestine grafts without bowel decontamination.
Clouse, Jared W; Kubal, Chandrashekhar A; Fridell, Jonathan A; Mangus, Richard S
2018-05-01
Selective digestive decontamination is commonly used to decrease lumenal bacterial flora. Preoperative bowel decontamination may be associated with a lower wound infection rate but has not been shown to decrease risk of intra-abdominal abscess or lower leak rate for enteric anastomoses. Alternatively, the decontamination disrupts the normal flora of the gastrointestinal tract and may affect normal physiology, including immunologic function. This study reports complication rates of an intestine transplant program that has never used bowel decontamination. All adult patients who underwent intestine transplant from 2003 to 2015 at a single center were reviewed. Posttransplant complications included intra-abdominal abscess, enteric fistula, and leak from the enteric anastomosis. Viral, fungal, and bacterial infections in the first year after transplant are reported. There were 184 adult patients who underwent deceased donor intestine transplant during the study period. Among these patients, 30% developed an infected postoperative fluid collection, 4 developed an enteric fistula (2%), and 16 had an enteric or anastomotic leak (8%). The rate of any bacterial infection was 91% in the first year, with a wound infection rate of 25%. Fungal infection occurred in 47% of patients. Rejection rates were 55% at 1 y for isolated intestine patients and 17% for multivisceral (liver inclusive) patients. Among this population of intestine transplant patients in which no bowel decontamination was used, rates of surgical complications, infections, and rejection were similar to those reported by other centers. Bowel decontamination provides no identifiable benefit in intestine transplantation. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Griffin, Timothy P.; Naylor, Guy R.; Haskell, William D.; Breznik, Greg S.; Mizell, Carolyn A.; Helms, William R.; Voska, N. (Technical Monitor)
2002-01-01
An on-line gas monitoring system was developed to replace the older systems used to monitor for cryogenic leaks on the Space Shuttles before launch. The system uses a mass spectrometer to monitor multiple locations in the process, which allows the system to monitor all gas constituents of interest in a nearly simultaneous manner. The system is fully redundant and meets all requirements for ground support equipment (GSE). This includes ruggedness to withstand launch on the Mobile Launcher Platform (MLP), ease of operation, and minimal operator intervention. The system can be fully automated so that an operator is notified when an unusual situation or fault is detected. User inputs are through personal computer using mouse and keyboard commands. The graphical user for detecting cryogenic leaks, many other gas constituents could be monitored using the Hazardous Gas Detection System (HGDS) 2000.
Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén
To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Stellar-based calibration in the far infrared with application to IRAS Band 4
NASA Technical Reports Server (NTRS)
Kirby, D. J.; Rieke, G. H.; Lebofsky, L. A.
1994-01-01
Because stars emit very small portions of their outputs in the far infrared, using them as calibrators requires precise measurement and correction for filter leaks at shorter wavelengths. Therefore, it is common to base far infrared calibrations on planetary objects such as asteriods. However, asteroids are complex geological bodies whose thermal properties depend on their evolutionary histories as well as on their gross parameters such as mass and composition, making them difficult to model as calibrators. We propose a new method for measuring filter leaks that can be carried out using the end-to-end detector system and therefore allows reliable use of stellar calibrators. We illustrate this method by showing that the Infrared Astronomy Satellite (IRAS) 100 micrometers (Band 4) filters had a short wavelength leak of 14.3% +/- 3.6% on stars similar to alpha Boo, but that there is no detectable leak in the 60 micrometers (Band 3) filters. We derive a calibration for Band 4 from stellar colors in a way that is closely analogous to the calibrations of Bands 1, 2, and 3. With correction for the leak, the stellar-based calibration is virtually identical to the original calibration based on asteroids; this result requires that the spectra of the asteriods for the original calibration differ from greybody behavior between 60 and 100 micrometers by about 10%.
Cerebrospinal fluid leak (image)
... brain and spinal cord by acting like a liquid cushion. The fluid allows the organs to be buoyant protecting them from blows or other trauma. Inside the skull the cerebrospinal fluid is contained by the dura which covers ...
Spleen and Lymphatic System (For Parents)
... they have many tiny openings that allow gases, water, and nutrients to pass through to the surrounding cells, nourishing them and taking away waste products. When lymph fluid leaks through in this way it is called interstitial ...
Gooszen, J A H; Goense, L; Gisbertz, S S; Ruurda, J P; van Hillegersberg, R; van Berge Henegouwen, M I
2018-04-01
Studies comparing the anastomotic leak rate in patients with an intrathoracic versus a cervical anastomosis after oesophagectomy are equivocal. The aim of this study was to compare clinical outcome after oesophagectomy in patients with an intrathoracic or cervical anastomosis, and to identify predictors of anastomotic leakage in a nationwide audit. Between January 2011 and December 2015, all consecutive patients who underwent oesophagectomy for cancer were identified from the Dutch Upper Gastrointestinal Cancer Audit. For the comparison between an intrathoracic and cervical anastomosis, propensity score matching was used to adjust for potential confounders. Multivariable logistic regression modelling with backward stepwise selection was used to determine independent predictors of anastomotic leakage. Some 3348 patients were included. After propensity score matching, 654 patients were included in both the cervical and intrathoracic anastomosis groups. An intrathoracic anastomosis was associated with a lower leak rate than a cervical anastomosis (17·0 versus 21·9 per cent; P = 0·025). The percentage of patients with recurrent nerve paresis was also lower (0·6 versus 7·0 per cent; P < 0·001) and an intrathoracic anastomosis was associated with a shorter median hospital stay (12 versus 14 days; P = 0·001). Multivariable analysis revealed that ASA fitness grade III or higher, chronic obstructive pulmonary disease, cardiac arrhythmia, diabetes mellitus and proximal oesophageal tumours were independent predictors of anastomotic leakage. An intrathoracic oesophagogastric anastomosis was associated with a lower anastomotic leak rate, lower rate of recurrent nerve paresis and a shorter hospital stay. Risk factors for anastomotic leak were co-morbidities and proximal tumours. © 2018 The Authors. BJS published by John Wiley & Sons Ltd on behalf of BJS Society Ltd.
NASA Technical Reports Server (NTRS)
Burrows, W. H.; Burrows, W. H.
1971-01-01
A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.
NASA Astrophysics Data System (ADS)
Alden, C. B.; Coburn, S.; Wright, R.; Baumann, E.; Cossel, K.; Sweeney, C.; Ghosh, S.; Newbury, N.; Prasad, K.; Coddington, I.; Rieker, G. B.
2017-12-01
Advances in natural gas extraction technology have led to increased US production and transport activity, and as a consequence, an increased need for monitoring of methane leaks. Current leak detection methods provide time snapshots, and not continuous, time-varying estimates of emissions. Most approaches also require specific atmospheric conditions, operators, or the use of a tracer gas, requiring site access. Given known intermittency in fugitive methane emissions, continuous monitoring is a critical need for emissions mitigation. We present a novel leak detection method that employs dual frequency comb spectrometry to offer continuous, autonomous, leak detection and quantification over square-km scale areas. The spectrometer is situated in a field of natural gas pads, and a series of retroreflectors around the field direct light back to a detector. The laser light spans 1620-1680 nm with 0.002 nm line spacing, measuring thousands of individual absorption features from multiple species. The result is high-stability trace gas (here CH4, CO2, and H2O) measurements over long (1 km+) open paths through the atmosphere. Measurements are used in an atmospheric inversion to estimate the time variability of emissions at each location of interest. Importantly, the measurement framework and inversion solve explicitly for background concentrations, which vary rapidly in fields of active oil and gas production. We present the results of controlled-leak field tests in rural Colorado. We demonstrate the ability to locate and size a leak located 1 km away from the spectrometer and varying in strength from 1.5 to 7.7 g/min, resulting in mean atmospheric enhancements of 20 ppb. The inversion correctly identifies when the leak turned on and off over a 24-hour period, and determines the mean leak strength to within 10% of the true controlled rate. We further demonstrate the ability of the system to correctly locate and size the start and end of simultaneous 2.7 to 4.8 g/min leaks from 2 sources in a field of 5 potential leak locations. Finally, we present the results of leak-detection tests in active oil and gas fields in the Denver Julesburg Basin, where background methane is complex.
Kim, Yong Doo; Kang, Ji Hwan; Bae, Hyun Kil; Kang, Namgoo; Oh, Sang Hyub; Lee, Jin-Hong; Woo, Jin Chun; Lee, Sangil
2017-11-21
Liquid hydrocarbon mixtures such as liquefied petroleum gas and liquefied natural gas are becoming integral parts of the world's energy system. Certified reference materials (CRMs) of liquid hydrocarbon mixtures are necessary to allow assessment of the accuracy and traceability of the compositions of such materials. A piston-type constant-pressure cylinder (PCPC) comprising chambers for a pressurizing gas (helium) and liquid (hydrocarbons) separated by a piston can be used to develop accurate and traceable liquid hydrocarbon mixture CRMs. The development of accurate CRMs relies on the maintenance of their composition. However, a PCPC might allow hydrocarbons to leak owing to the imperfect seal of the piston. In this study, a novel leak-free bellows-type constant-pressure cylinder (BCPC) is designed and evaluated by comparison with PCPCs. Liquid hydrocarbon mixtures consisting of ethane, propane, propene, isobutane, n-butane, 1-butene, and isopentane were prepared in both types of constant pressure cylinders and then monitored to check leakages between the gas and liquid chambers. Overall, notable leakage occurred from and into both chambers in the PCPCs, whereas no leakage occurred in the BCPCs in the three months after their gravimetric preparation. The BCPCs maintained no leakage even 10 months after their preparation, whereas the PCPCs showed significantly increasing leakage during the same period.
Heuristics and bias in rectal surgery.
MacDermid, Ewan; Young, Christopher J; Moug, Susan J; Anderson, Robert G; Shepherd, Heather L
2017-08-01
Deciding to defunction after anterior resection can be difficult, requiring cognitive tools or heuristics. From our previous work, increasing age and risk-taking propensity were identified as heuristic biases for surgeons in Australia and New Zealand (CSSANZ), and inversely proportional to the likelihood of creating defunctioning stomas. We aimed to assess these factors for colorectal surgeons in the British Isles, and identify other potential biases. The Association of Coloproctology of Great Britain and Ireland (ACPGBI) was invited to complete an online survey. Questions included demographics, risk-taking propensity, sensitivity to professional criticism, self-perception of anastomotic leak rate and propensity for creating defunctioning stomas. Chi-squared testing was used to assess differences between ACPGBI and CSSANZ respondents. Multiple regression analysis identified independent surgeon predictors of stoma formation. One hundred fifty (19.2%) eligible members of the ACPGBI replied. Demographics between ACPGBI and CSSANZ groups were well-matched. Significantly more ACPGBI surgeons admitted to anastomotic leak in the last year (p < 0.001). ACPGBI surgeon age over 50 (p = 0.02), higher risk-taking propensity across several domains (p = 0.044), self-belief in a lower-than-average anastomotic leak rate (p = 0.02) and belief that the average risk of leak after anterior resection is 8% or lower (p = 0.007) were all independent predictors of less frequent stoma formation. Sensitivity to criticism from colleagues was not a predictor of stoma formation. Unrecognised surgeon factors including age, everyday risk-taking, self-belief in surgical ability and lower probability bias of anastomotic leak appear to exert an effect on decision-making in rectal surgery.
Does the type of pancreaticojejunostomy after Whipple alter the leak rate?
Ball, Chad G; Howard, Thomas J
2010-01-01
Despite the overwhelming limitations that plague the literature surrounding the optimal method of reestablishing pancreatico-enteric continuity following a Whipple operation, it is clear that all successful techniques conform to sound surgical principles. These principles include a water-tight and tension-free anastomosis, preservation of adequate blood supply for both organs involved in the anastomosis, and minimal trauma to the pancreas gland. Although surgeon experience, gland texture, and pancreatic duct size are clearly the dominate risk factors from a long list of variables associated with pancreatic leaks following pancreatoduodenectomy, these are nonmodifiable covariates. Although the plethora of current literature cannot provide a single definitive technical solution for restoring pancreatico-enteric continuity, a small number of well-designed RCTs support the use of transanastomotic external stenting for high-risk pancreatic glands and an end-to-side invaginated pancreaticojejunostomy. The truth remains that an individual surgeon's mastery of a specific anastomotic technique, in conjunction with a large personal experience, is likely to be the best predictor of a low pancreas leak rate following pancreatoduodenectomy.
75 FR 17169 - Nextera Energy Duane Arnold, LLC, Duane Arnold Energy Center; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... leakage from the overall integrated leak rate test measurement. Main steam leakage includes leakage... integrated leakage rate (Type A) test measurement and from the sum of the leakage rates from local leakage... leakage rate (Type A) test [[Page 17170
van Halsema, Emo E; van Hooft, Jeanin E
2015-01-01
AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and fistulae is promising. PMID:25685270
Zhang, Liwei; Anderson, Nicole; Dilmore, Robert; Soeder, Daniel J; Bromhal, Grant
2014-09-16
Potential natural gas leakage into shallow, overlying formations and aquifers from Marcellus Shale gas drilling operations is a public concern. However, before natural gas could reach underground sources of drinking water (USDW), it must pass through several geologic formations. Tracer and pressure monitoring in formations overlying the Marcellus could help detect natural gas leakage at hydraulic fracturing sites before it reaches USDW. In this study, a numerical simulation code (TOUGH 2) was used to investigate the potential for detecting leaking natural gas in such an overlying geologic formation. The modeled zone was based on a gas field in Greene County, Pennsylvania, undergoing production activities. The model assumed, hypothetically, that methane (CH4), the primary component of natural gas, with some tracer, was leaking around an existing well between the Marcellus Shale and the shallower and lower-pressure Bradford Formation. The leaky well was located 170 m away from a monitoring well, in the Bradford Formation. A simulation study was performed to determine how quickly the tracer monitoring could detect a leak of a known size. Using some typical parameters for the Bradford Formation, model results showed that a detectable tracer volume fraction of 2.0 × 10(-15) would be noted at the monitoring well in 9.8 years. The most rapid detection of tracer for the leak rates simulated was 81 days, but this scenario required that the leakage release point was at the same depth as the perforation zone of the monitoring well and the zones above and below the perforation zone had low permeability, which created a preferred tracer migration pathway along the perforation zone. Sensitivity analysis indicated that the time needed to detect CH4 leakage at the monitoring well was very sensitive to changes in the thickness of the high-permeability zone, CH4 leaking rate, and production rate of the monitoring well.
van Halsema, Emo E; van Hooft, Jeanin E
2015-02-16
To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and fistulae is promising.
ERIC Educational Resources Information Center
Helseth, Lars Egil
2014-01-01
I describe a simple and fascinating experiment wherein helium leaks out of a rubber balloon, thereby causing it to descend. An estimate of the volumetric leakage rate is made by measuring its rate of descent.
Plant Operation: Exterior Maintenance, Work Hours
ERIC Educational Resources Information Center
Nation's Schools and Colleges, 1975
1975-01-01
A pitched roof built over a flat roof prevented leaking at a Vermont school. The University of New Hampshire paint shop has a flexible scheduling system that allows employees to choose their work hours each day. (Author/MLF)
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.
Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks
NASA Technical Reports Server (NTRS)
Youngquist, Robert; Starr, Stanley; Nurge, Mark
2012-01-01
Large cryogenic liquid hydrogen tanks are composed of inner and outer shells. The outer shell is exposed to the ambient environment while the inner shell holds the liquid hydrogen. The region between these two shells is evacuated and typically filled with a powderlike insulation to minimize radiative coupling between the two shells. A technique was developed for detecting the presence of an air leak from the outside environment into this evacuated region. These tanks are roughly 70 ft (approx. equal 21 m) in diameter (outer shell) and the inner shell is roughly 62 ft (approx. equal 19 m) in diameter, so the evacuated region is about 4 ft (approx. equal 1 m) wide. A small leak's primary effect is to increase the boil-off of the tank. It was preferable to install a more accurate fill level sensor than to implement a boil-off meter. The fill level sensor would be composed of an accurate pair of pressure transducers that would essentially weigh the remaining liquid hydrogen. This upgrade, allowing boil-off data to be obtained weekly instead of over several months, is ongoing, and will then provide a relatively rapid indication of the presence of a leak.
A Fiber-Optic Sensor for Leak Detection in a Space Environment
NASA Technical Reports Server (NTRS)
Sinko, John E.; Korman, Valentin; Hendrickson, Adam; Polzin, Kurt A.
2009-01-01
A miniature fiber-optic, laser-based, interferometric leak detector is presented for application as a means to detect on-orbit gas leaks. The sensor employs a fiber-coupled modified Michelson interferometer to detect gas leaks by measuring an increase in gas density in the sensing region. Monitoring changes in the fringe pattern output by the interferometer allows for direct measurement of the gas density in the sensing region and, under the assumption of an equation of state, this can be used to obtain a pressure measurement. Measurements obtained over a pressure range from 20 mtorr to 760 torr using a prototypical interferometer on working gases of air, nitrogen, argon, and helium generally exhibit agreement with a theoretical prediction of the pressure increase required before an interference fringe completely moves over the detector. Additional measurements performed on various gases demonstrate the range of detectable species, measuring sub-torr pressure changes in the process. A high-fidelity measurement places the ultimate pressure resolution for this particular sensor configuration in the 10 mtorr range. Time-resolved data prove the capability of this sensor to detect fast gas flow phenomena associated with transients and pressure waves.
Gross, Kenny C.
1994-01-01
Failure of a fuel element in a nuclear reactor core is determined by a gas tagging failure detection system and method. Failures are catalogued and characterized after the event so that samples of the reactor's cover gas are taken at regular intervals and analyzed by mass spectroscopy. Employing a first set of systematic heuristic rules which are applied in a transformed node space allows the number of node combinations which must be processed within a barycentric algorithm to be substantially reduced. A second set of heuristic rules treats the tag nodes of the most recent one or two leakers as "background" gases, further reducing the number of trial node combinations. Lastly, a "fuzzy" set theory formalism minimizes experimental uncertainties in the identification of the most likely volumes of tag gases. This approach allows for the identification of virtually any number of sequential leaks and up to five simultaneous gas leaks from fuel elements.
Heavily T2-weighted MR myelography vs CT myelography in spontaneous intracranial hypotension.
Wang, Y-F; Lirng, J-F; Fuh, J-L; Hseu, S-S; Wang, S-J
2009-12-01
To assess the diagnostic accuracy of heavily T2-weighted magnetic resonance myelography (MRM) in patients with spontaneous intracranial hypotension (SIH). Patients with SIH were recruited prospectively, and first underwent MRM and then computed tomographic myelography (CTM). The results of MRM were validated with the gold standard, CTM, focusing on 1) CSF leaks along the nerve roots, 2) epidural CSF collections, and 3) high-cervical (C1-3) retrospinal CSF collections. Comparisons of these 3 findings between the 2 studies were made by kappa statistics and agreement rates. Targeted epidural blood patches (EBPs) were placed at the levels of CSF leaks if supportive treatment failed. Nineteen patients (6 men and 13 women, mean age 37.9 +/- 8.6 years) with SIH completed the study. MRM did not differ from CTM in the detection rates of CSF leaks along the nerve roots (84% vs 74%, p = 0.23), high-cervical retrospinal CSF collections (32% vs 16%, p = 0.13), and epidural CSF collections (89% vs 79%, p = 0.20). MRM demonstrated more spinal levels of CSF leaks (2.2 +/- 1.7 vs 1.5 +/- 1.5, p = 0.011) and epidural collections (12.2 +/- 5.9 vs 7.1 +/- 5.8, p < 0.001) than CTM. The overall level-by-level concordance was substantial for CSF leaks along the nerve roots (C1-L3) (kappa = 0.71, p < 0.001, agreement = 95%) and high-cervical retrospinal CSF collections (C1-3) (kappa = 0.73, p < 0.001, agreement = 92%), and moderate for epidural CSF collections (C1-L3) (kappa = 0.47, p < 0.001, agreement = 72%). Ten of the 14 patients (71%) receiving targeted EBPs experienced sustained symptomatic relief after a single attempt. Heavily T2-weighted magnetic resonance myelography was accurate in localizing CSF leaks for patients with spontaneous intracranial hypotension. This noninvasive technique may be an alternative to computed tomographic myelography before targeted epidural blood patches.
Monitoring CCS Sites: Lessons Learned Studying Natural Laboratories.
NASA Astrophysics Data System (ADS)
Tartarello, M. C.; Beaubien, S. E.; Graziani, S.; Lombardi, S.; Ruggiero, L.
2016-12-01
Monitoring is one of the most important aspects of Carbon Capture and Storage (CCS), both for early recognition of leaks from the reservoir and for public safety. Natural analogues could be useful to understand the potential impact of a leakage on the local ecosystem and to develop new techniques of monitoring. These sites, called also "natural laboratories", are characterized by natural, geologically-produced CO2 constantly leaking from the seafloor or from the groundsurface. In the last 10 years, our group as partner of some EC funded projects focused on CCS (NASCENT (2000-2003), CO2GeoNet (2004-2009), CO2ReMoVe (2006-2011), RISCS (2010-2013), and ECO2 (2011-2015)), studied gas migration mechanisms in these "natural laboratories", applying near-surface geochemistry to monitoring. This method provides one of the most powerful tools to assess whether a CCS site is leaking and, if it is, to quantify that leakage. This is because rather than being a remote method that estimates amounts based on proxy associations, such as some geophysical tools, it is an exact measurement of the item of interest (in this case CO2) in the accessible biosphere where there is concern regarding its potential impact. In particular, we have been studied two sites in Italy, characterized by significant emissions of CO2, related to volcanic emissions: the Latera Caldera (in Central Italy) and the offshore emissions near Panarea Island. We combined continuous and discontinuous monitoring, structural surveys and gas flux measurements. The results show a strong correlation between fault architecture and leakage rates. Moreover, the monitoring of an area for long periods allows defining the baseline, which is the fluctuation of gas concentrations both spatially and temporally as a function of biological, chemical, geological, land-use and meteorological processes.
Xu, Kai; Chen, Shaomu; Bian, Wen; Xie, Hongya; Ma, Haitao; Ni, Bin
2016-07-01
Intrathoracic esophagogastric anastomotic leak is a critical complication after esophagectomy. Recently, novel complex diagnostic and therapeutic managements for intrathoracic esophagogastric anastomotic leak have been performed at our institution. Sixty-seven consecutive patients with intrathoracic esophagogastric anastomotic leak after esophagectomy from January 2009 to May 2015 at our institution were reviewed. Thirty-nine patients received conventional managements (conventional group), in which they were diagnosed via contrast swallow when there was a suspicion of anastomotic leak and were subsequently treated with a metallic stent. Twenty-eight patients received complex managements (complex group), in which they were diagnosed using digital subtraction angiography, an intraluminal drainage tube was placed, and clips were subsequently performed under an endoscope. The outcomes of the two groups were retrospectively analyzed. There were no significant differences (P > 0.05) between the two groups in the preoperative general clinical data, whereas the postoperative data exhibited some differences. Compared with the conventional group, the confirmation time and recovery time are significantly decreased in the complex group (P < 0.01 and P < 0.01, respectively), and the incidence of severe complications is also lower (P < 0.01); however, there were no significant differences in the mortality rate between the two groups (P > 0.05). Complex managements may represent a useful therapeutic option for postoperative esophagogastric anastomotic leak. Copyright © 2016 Elsevier Inc. All rights reserved.
Use of duraseal in repair of cerebrospinal fluid leaks.
Chin, Christopher J; Kus, Lukas; Rotenberg, Brian W
2010-10-01
The purpose of our article is to review the use of the DuraSeal Sealant System (Confluent Surgical Inc., Waltham, MA) in the repair of complex cerebrospinal fluid (CSF) leaks in endoscopic skull-base surgery. Retrospective chart review. London Health Sciences Centre. A database of endoscopic skull-base cases between 2007 and 2009 that involved CSF leakage repaired with DuraSeal was created. Demographic data and operative reports were collected and analyzed qualitatively. Recurrence of CSF leak after repair. Five cases were identified that met study criteria. In four of the five cases, the repair was successful. There were no complications related to DuraSeal use. Comparison to a subset of patients using Tisseel Fibrin Sealant (Baxter, Toronto, ON) for repair did not show a significant difference in failure rate (χ2 = 0.029, p = .858). There are a variety of techniques described to repair CSF rhinorrhea, with various studies demonstrating the advantages of using tissue glues in CSF leak repairs. We used DuraSeal in five patients to enhance graft strength and form a watertight seal. The system was effective in the majority of patients. Our study is the first to report on endoscopic endonasal repair of CSF leaks using DuraSeal.
NASA Astrophysics Data System (ADS)
Ravikumar, A. P.; Wang, J.; Brandt, A. R.
2016-12-01
Mitigating fugitive methane emissions from the oil and gas industry has become an important concern for both businesses and regulators. While recent studies have improved our understanding of emissions from all sectors of the natural gas supply chain, cost-effectively identifying leaks over expansive natural gas infrastructure remains a significant challenge. Recently, the Environmental Protection Agency (EPA) has recommended the use of optical gas imaging (OGI) technologies to be used in industry-wide leak detection and repair (LDAR) programs. However, there has been little to no systematic study of the effectiveness of infrared-camera-based OGI technology for leak detection applications. Here, we develop a physics-based model that simulates a passive infrared camera imaging a methane leak against varying background and ambient conditions. We verify the simulation tool through a series of large-volume controlled release field experiments wherein known quantities of methane were released and imaged from a range of distances. After simulator verification, we analyze the effects of environmental conditions like temperature, wind, and imaging background on the amount of methane detected from a statistically representative survey program. We also examine the effects of LDAR design parameters like imaging distance, leak size distribution, and gas composition. We show that imaging distance strongly affects leak detection - EPA's expectation of a 60% reduction in fugitive emissions based on a semi-annual LDAR survey will be realized only if leaks are imaged at a distance less than 10 m from the source under ideal environmental conditions. Local wind speed is also shown to be important. We show that minimum detection limits are 3 to 4 times higher for wet-gas compositions that contain a significant fraction of ethane and propane, resulting a significantly large leakage rate. We also explore the importance of `super-emitters' on the performance of an OGI-based leak detection program, and show that OGI technology can be used as an approximate leak-quantification method to selectively target the biggest leaks. Finally, we also provide recommendations and best-practices guidelines for achieving expected methane mitigation.
Suzuki, Takayuki; Siddiqui, Ali; Taylor, Linda J; Cox, Kristen; Hasan, Raza A; Laique, Sobia N; Mathew, Arun; Wrobel, Piotr; Adler, Douglas G
2016-01-01
Esophageal stents are commonly used to treat benign esophageal conditions including refractory benign esophageal strictures, anastomotic strictures, fistulae, perforations and anastomotic leaks. Data on outcomes in these settings remain limited. We performed a retrospective multicenter study of patients who underwent fully or partially covered self-expandable stent placement for benign esophageal diseases. Esophageal stent placements were performed for the following indications: (1) benign refractory esophageal strictures, (2) surgical anastomotic strictures, (3) esophageal perforations, (4) esophageal fistulae, and (5) surgical anastomotic leaks. A total of 70 patients underwent esophageal stent placement for benign esophageal conditions. A total of 114 separate procedures were performed. The most common indication for esophageal stent placement was refractory benign esophageal stricture (48.2%). Global treatment success rate was 55.7%. Treatment success rate was 33.3% in refractory benign strictures, 23.1% in anastomotic strictures, 100% in perforations, 71.4% in fistulae, and 80% in anastomotic leaks. Stent migration was noted in 28 of 70 patients (40%), most commonly seen in refractory benign strictures. This is one of the largest studies to date of esophageal stents to treat benign esophageal diseases. Success rates are lowest in benign esophageal strictures. These patients have few other options beyond chronic dilations, feeding tubes, and surgery, and fully covered self-expandable metallic stent give patients a chance to have their problem fixed endoscopically and still eat by mouth. Perforations, fistulas, and leaks respond very well to esophageal stenting, and stenting should be considered as a first-line therapy in these settings.
Shehab, Hany; Abdallah, Emad; Gawdat, Khaled; Elattar, Inas
2018-01-01
Endoscopic stents are successful in the management of surgical leaks; however, stent migration remains a significant problem. In this study, we present our approach depending on a large bariatrics-specific stent (Mega stent) and over-the-scope clips in the management of post-bariatric surgery leaks. A retrospective analysis of all patients with post-bariatric surgery leaks treated at our institution using an approach reliant on Mega stents and over-the-scope clips was conducted. Potential factors associated with procedure success and occurrence of complications were also evaluated. A total of 81 stents were inserted in 62 patients with post-bariatric surgery leaks, 46 sleeve gastrectomies (73%) and 16 Roux-en-Y gastric bypass (27%). Over-the-scope clips were applied in 29 patients (46%). Leak closure was achieved in 51 patients (82%). Median number of procedures per patient was 3 (range 2-8). Complications included the following: stent migration (11/62, 18%), intolerance necessitating premature removal (7/62, 11%), esophageal stricture (8/62, 13%), bleeding (4/62, 6%), perforation (4/62, 6%). One stent-induced mortality was encountered (bleeding). The presence of open surgery (vs laparoscopic) was significantly associated with the occurrence of stent-induced complications (p 0.002). The approach combining Mega stents and over-the-scope clips is highly effective in the management of post-bariatric surgery leaks and is associated with a low rate of stent migration and a low number of procedures and stents per patient. Mega stents, however, should be used with great caution due to the significant morbidity associated with their use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baek, Yoolim; Won, Je Hwan; Kong, Tae-Wook
PurposeTo analyze imaging findings of lymphatic leakage associated with surgical lymph node dissection on lymphangiography and assess the outcome of lymphatic embolization.Materials and MethodsThis retrospective study comprised 21 consecutive patients who were referred for lymphatic intervention between March 2014 and April 2015 due to postsurgical lymphatic leaks. Lymphangiography was performed through inguinal lymph nodes to identify the leak. When a leak was found, lymphatic embolization was performed by fine-needle injection of N-butyl cyanoacrylate into the site of leakage or into an inflow lymphatic vessel or into a pelvic lymph node located below the leakage. Electronic medical records and imaging studiesmore » were reviewed to assess the outcome.ResultLymphangiography revealed single or multiple leaks in all but one patient. Lymphatic embolization was performed in 20 patients with leaks. Including the patient who did not undergo embolization, 17 patients (81.0 %) showed initial response to treatment. Three patients underwent repeated embolization with successful results. The overall success rate was 95.2 %. The mean duration of hospitalization after lymphatic intervention was 5.9 days. During a mean follow-up period of 11 months, two patients developed localized swelling in the groin following lipiodol injection. There were no complications related to lymphatic embolization. Three patients were found to have developed small, asymptomatic lymphoceles on CT or MRI that did not require further treatment.ConclusionLymphangiography is useful for detecting lymphatic leakage occurring after lymph node dissection. Furthermore, lymphatic embolization is feasible, effective, and safe for managing leaks demonstrated on lymphangiography.« less
Pneumostasis of experimental air leaks with a new photopolymerized synthetic tissue sealant.
Ranger, W R; Halpin, D; Sawhney, A S; Lyman, M; Locicero, J
1997-09-01
Air leak is a major contributor to increased length of stay and postoperative morbidity following pulmonary surgery. The effectiveness of a new photopolymerized synthetic hydrogel (FocalSeal, Focal, Inc., Lexington, MA) as a sealant for pulmonary air leaks was determined in 10 mongrel dogs (20-35 kg). The animals were anesthetized and underwent left-sided anterolateral thoracotomy with amputation of a 2 x 3-cm segment of the lung apex. Hemostasis was achieved and terminal bronchial openings of 1.5 to 3 mm with vigorous air leaks were identified. After successful injury, the dogs were randomly assigned to sealant (n = 5) or control (n = 5) groups. In treated animals, the sealant was applied by brushing the solution to the cut parenchymal surface and solidified while briefly interrupting ventilation (40-60 seconds) using visible illumination (450-550 nm) from a xenon light source. Controls received no sealant. A single chest tube was maintained at the injury site with a continuous negative pressure of 20 cm of water. All dogs were extubated and allowed to breathe spontaneously under sedation for 24 hours. Chest radiographs were taken postsurgery and presacrifice. All control animals (n = 5) showed persistent vigorous air leak for the duration of the 24-hour observation period. All treated air leaks resolved immediately, and four of five remained sealed throughout the observation period. One leak reappeared after 17 hours due to inadequate sealant thickness over a 3-mm terminal bronchus. Gross evaluation of the treatment group at the end of 24 hours demonstrated intact sealant well adherent to the parenchyma. No evidence of atelectasis or excessive edema was seen, and no sealant-related complications or toxic effects were noted. Radiologically, lungs were fully inflated. Histologic evaluation at 24 hours revealed no evidence of a strong cellular response to the synthetic sealant, and no fibrosis or adhesions were seen, the onset of the healing process was favorable, indicating good biocompatability. In conclusion, this material was found to be an effective means for sealing bronchial and parenchymal air leaks in this model and warrants clinical evaluation.
A model for the effect of real leaks on the transport of microorganisms into a vacuum freeze-dryer.
Jennings, T A
1990-01-01
This paper proposes a model for determining the effect that real leaks, whose flow is viscous in nature, could have on the microorganism density in a vacuum freeze-dryer during a drying process. The model considers the entry of microorganisms to result from real leaks stemming from an environment containing a known bioburden. A means for determining the relationship between the rate of pressure rise of the system (ROR) and the density of microorganisms in a system, stemming from an environment of a known bioburden, is examined. The model also considers the change in the bioburden of the dryer with respect to variations in the primary and secondary drying process.
40 CFR 265.259 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... response action plan must set forth the actions to be taken if the action leakage rate has been exceeded... section. (b) If the flow rate into the leak determination system exceeds the action leakage rate for any... notification that the action leakage rate has been exceeded, submit to the Regional Administrator the results...
Comparison of face masks in the bag-mask ventilation of a manikin.
Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S
2006-02-01
We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.
40 CFR 265.222 - Action leakage rate.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to § 265.221(a). The action leakage rate is the maximum design flow rate that the leak detection... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Action leakage rate. 265.222 Section... FACILITIES Surface Impoundments § 265.222 Action leakage rate. (a) The owner or operator of surface...
Flood Syndrome: Spontaneous Umbilical Hernia Rupture Leaking Ascitic Fluid—A Case Report
Nguyen, Emilie T; Tudtud-Hans, Leah A
2017-01-01
Introduction We report a rare case of Flood syndrome, which is a spontaneous rupture of an umbilical hernia. Case Presentation A 42-year-old man with decompensated hepatitis C and alcoholic cirrhosis complicated by ascites and esophageal varices presented with 1 day of ascitic fluid drainage after rupture of a preexisting umbilical hernia associated with diffuse abdominal pain and tenderness. A pigtail drain was placed in the right upper abdominal quadrant to decrease fluid drainage from the abdominal wall defect, allowing it to heal naturally. Discussion The spontaneous rupture of an umbilical hernia in our patient highlights a rare complication with high mortality rates and stresses the challenge of treatment that falls in the area between medical and surgical management. PMID:28678688
Flood Syndrome: Spontaneous Umbilical Hernia Rupture Leaking Ascitic Fluid-A Case Report.
Nguyen, Emilie T; Tudtud-Hans, Leah A
2017-01-01
We report a rare case of Flood syndrome, which is a spontaneous rupture of an umbilical hernia. A 42-year-old man with decompensated hepatitis C and alcoholic cirrhosis complicated by ascites and esophageal varices presented with 1 day of ascitic fluid drainage after rupture of a preexisting umbilical hernia associated with diffuse abdominal pain and tenderness. A pigtail drain was placed in the right upper abdominal quadrant to decrease fluid drainage from the abdominal wall defect, allowing it to heal naturally. The spontaneous rupture of an umbilical hernia in our patient highlights a rare complication with high mortality rates and stresses the challenge of treatment that falls in the area between medical and surgical management.
Refinery evaluation of optical imaging to locate fugitive emissions.
Robinson, Donald R; Luke-Boone, Ronke; Aggarwal, Vineet; Harris, Buzz; Anderson, Eric; Ranum, David; Kulp, Thomas J; Armstrong, Karla; Sommers, Ricky; McRae, Thomas G; Ritter, Karin; Siegell, Jeffrey H; Van Pelt, Doug; Smylie, Mike
2007-07-01
Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.
Field Trial of an Aerosol-Based Enclosure Sealing Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, Curtis; Springer, David
2015-09-01
This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology. However, this technology is capable of bringing the air leakage of a building that was built with standard construction techniques and HERS-verified sealing down to levels that would meet DOE Zero Energy Ready Homes program requirements. When a developer is striving to meet a tighter envelope leakage specification, this technology could greatly reduce the cost to achieve that goal by providing a simple and relatively low cost method for reducing the air leakage of a building envelope with little to no change in their common building practices.« less
NASA Astrophysics Data System (ADS)
Tso, C. H. M.; Johnson, T. C.; Song, X.; Chen, X.; Binley, A. M.
2017-12-01
Time-lapse electrical resistivity tomography (ERT) measurements provides indirect observation of hydrological processes in the Earth's shallow subsurface at high spatial and temporal resolutions. ERT has been used for a number of decades to detect leaks and monitor the evolution of associated contaminant plumes. However, this has been limited to a few hazardous environmental sites. Furthermore, an assessment of uncertainty in such applications has thus far been neglected, despite the clear need to provide site managers with appropriate information for decision making purposes. There is a need to establish a framework that allows leak detection with uncertainty assessment from geophysical observations. Ideally such a framework should allow the incorporation of additional data sources in order to reduce uncertainty in predictions. To tackle these issues, we propose an ensemble-based data assimilation framework that evaluates proposed hydrological models (i.e. different hydrogeological units, different leak locations and loads) against observed time-lapse ERT measurements. Each proposed hydrological model is run through the parallel coupled hydrogeophysical code PFLOTRAN-E4D (Johnson et al 2016) to obtain simulated ERT measurements. The ensemble of model proposals is then updated based on data misfit. Our approach does not focus on obtaining detailed images of hydraulic properties or plume movement. Rather, it seeks to estimate the contaminant mass discharge (CMD) across a user-defined plane in space probabilistically. The proposed approach avoids the ambiguity in interpreting detailed hydrological processes from geophysical images. The resultant distributions of CMD give a straightforward metric, with realistic uncertainty bounds, for decision making. The proposed framework is also computationally efficient so that it can exploit large, long-term ERT datasets, making it possible to track time-varying loadings of plume sources. In this presentation, we illustrate our framework on synthetic data and field data collected from an ERT trial simulating a leak at the Sellafield nuclear facility in the UK (Kuras et al 2016). We compare our results to interpretation from geophysical inversion and discuss the additional information that hydrological model proposals provide.
The effects of air leaks on solar air heating systems
NASA Technical Reports Server (NTRS)
Elkin, R.; Cash, M.
1979-01-01
This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.
40 CFR 60.482-9a - Standards: Delay of repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
... destroyed or recovered in a control device complying with § 60.482-10a. (d) Delay of repair for pumps will... repair is allowed for a leaking pump, valve, or connector that remains in service, the pump, valve, or...
40 CFR 60.482-9a - Standards: Delay of repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
... destroyed or recovered in a control device complying with § 60.482-10a. (d) Delay of repair for pumps will... repair is allowed for a leaking pump, valve, or connector that remains in service, the pump, valve, or...
40 CFR 60.482-9a - Standards: Delay of repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
... destroyed or recovered in a control device complying with § 60.482-10a. (d) Delay of repair for pumps will... repair is allowed for a leaking pump, valve, or connector that remains in service, the pump, valve, or...
Kam, M H; Tang, C L; Chan, E; Lim, J F; Eu, K W
2009-09-01
A systematic review was conducted to determine if manual decompression is a safe alternative to intraoperative colonic irrigation prior to primary anastomosis in obstructed left-sided colorectal emergencies. Search for relevant articles from 1980 to 2007 was conducted on Medline, Embase and the Cochrane Controlled Trials Register using the keywords "colonic lavage, irrigation, decompression, washout, obstructed and bowel preparation", either singularly or in combination. Trials in English publications with similar patient characteristics, inclusion criteria and outcome measures were selected for analysis. Thirty-day mortality, anastomotic leak rates and post-operative wound infection were studied as outcome variables. Analysis was performed with RevMan 4.2 software. Seven trials were identified for systematic review, with a total of 449 patients. Data from the single randomised controlled trial and one prospective comparative trial were analysed separately. Results from the remaining five studies were pooled into two arms of a composite series, one with colonic irrigation and one without. Results showed no significant difference in the anastomotic leak rates and mortality rates between the colonic irrigation and manual decompression arms in the randomised and comparative trials. The composite series, however, showed significantly better results with manual decompression (RR 6.18, 95% CI 1.67-22.86). The post-operative infection rate was similar in both groups. Manual decompression was comparable to colonic irrigation for primary anastomosis in obstructed left-sided colorectal emergencies, with no significant increase in mortality, leak or infection rates.
Campos, Guilherme M; Jablons, David; Brown, Lisa M; Ramirez, René M; Rabl, Charlotte; Theodore, Pierre
2010-06-01
In expert hands, the intrathoracic oesophago-gastric anastamosis usually provides a low rate of strictures and leaks. However, anastomoses can be technically challenging and time consuming when minimally invasive techniques are used. We present our preliminary results of a standardised 25 mm/4.8mm circular-stapled anastomosis using a trans-orally placed anvil. We evaluated a prospective cohort of 37 consecutive patients offered minimally invasive Ivor Lewis oesophagectomy at a tertiary referral centre. The oesophago-gastric anastomosis was created using a 25-mm anvil (Orvil, Autosuture, Norwalk, CT, USA) passed trans-orally, in a tilted position, and connected to a 90-cm long polyvinyl chloride delivery tube through an opening in the oesophageal stump. The anastomosis was completed by joining the anvil to a circular stapler (end-to-end anastomosis stapler (EEA XL) 25 mm with 4.8-mm staples, Autosuture, Norwalk, CT, USA) inserted into the gastric conduit. Primary outcomes were leak and stricture rates. Thirty-seven patients (mean age 65 years) with distal oesophageal adenocarcinoma (n=29), squamous cell cancer (n=5) or high-grade dysplasia in Barrett's oesophagus (n=3) underwent an Ivor Lewis oesophagectomy between October 2007 and August 2009. The abdominal portion was operated laparoscopically in 30 patients (81.1%). The thoracic portion was done using a muscle-sparing mini-thoracotomy in 23 patients (62.2%) and thoracoscopic techniques in 14 patients (37.8%). There were no intra-operative technical failures of the anastomosis or deaths. Five patients had strictures (13.5%) and all were successfully treated with endoscopic dilations. One patient had an anastomotic leak (2.7%) that was successfully treated by re-operation and endoscopic stenting of the anastomosis. The circular-stapled anastomosis with the trans-oral anvil allows for an efficient, safe and reproducible anastomosis. This straightforward technique is particularly suited to the completely minimally invasive Ivor Lewis oesophagectomy. Copyright 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Park, Jae Kil; Kim, Jae Jun; Moon, Seok Whan
2017-10-01
Anastomotic leak is one of most significant causes of mortality after esophagectomy. Therefore, it is clinically valuable to detect anastomotic leak early after esophagectomy in esophageal cancer. The purpose of this study is to investigate the associations between routine postoperative laboratory findings and anastomotic leak and to analyze the laboratory findings to find out an independent predictive marker for anastomotic leak. In addition, this study compares cases treated with neoadjuvant therapy (NT) and those without (non-NT). We retrospectively assessed the medical records of 201 consecutive cases that met this study's criteria from January 2009 to December 2016. All patients underwent curative and complete esophagectomy for intra-thoracic esophageal cancer. We compiled and analyzed routine laboratory findings from the day before surgery to the eighth postoperative day on a daily basis. Routine laboratory tests consisted of 26 separate tests, including complete blood cell counts, blood chemistries, as well as erythrocyte sedimentation rate and C-reactive protein (CRP). Barium esophagogram with chest computed tomography (CT) was performed on the seventh postoperative day to evaluate the presence of an anastomotic leak. A total of 45 of 201 patients underwent NT. Anastomotic leaks were found in 23 (11.4%) of 201 patients (8 patients in NT and 15 patients in non-NT). White blood cell (WBC) from the second postoperative day (P=0.031, P=0.006, P=0.007, P=0.007, P=0.041, and P=0.003, respectively) and CRP from the third postoperative day (P=0.012, P<0.001, P=0.014, P<0.001, P=0.001, and P=0.006, respectively) were associated with anastomotic leak in non-NT; however, only CRP on the third, fifth, sixth, and seventh postoperative days (P=0.041, P=0.037, P=0.002, and P=0.003, respectively) was associated with anastomotic leak in NT. The CRP level on the third postoperative day was a significant independent predictive marker of anastomotic leak (P=0.041, odd ratio (OR) 1.056, 95% confidential interval (CI): 1.002-1.113) and had a significant diagnostic cutoff value for the development of anastomotic leak (non-NT: cutoff value 17.12 mg/dL, sensitivity 69.2%, specificity 78.1%, P<0.001, area 0.822; NT: cutoff value 16.42 mg/dL, sensitivity 80.0%, specificity 70.0%, P=0.042, area 0.7104). There were divergent laboratory findings reflective of anastomotic leak between patients who underwent NT and those who did not. The CRP level on the third postoperative day had a significant cutoff value for early detection of anastomotic leak after esophagectomy in both NT and non-NT groups.
Digital logic circuits in yeast with CRISPR-dCas9 NOR gates
Gander, Miles W.; Vrana, Justin D.; Voje, William E.; Carothers, James M.; Klavins, Eric
2017-01-01
Natural genetic circuits enable cells to make sophisticated digital decisions. Building equally complex synthetic circuits in eukaryotes remains difficult, however, because commonly used components leak transcriptionally, do not arbitrarily interconnect or do not have digital responses. Here, we designed dCas9-Mxi1-based NOR gates in Saccharomyces cerevisiae that allow arbitrary connectivity and large genetic circuits. Because we used the chromatin remodeller Mxi1, our gates showed minimal leak and digital responses. We built a combinatorial library of NOR gates that directly convert guide RNA (gRNA) inputs into gRNA outputs, enabling the gates to be ‘wired' together. We constructed logic circuits with up to seven gRNAs, including repression cascades with up to seven layers. Modelling predicted the NOR gates have effectively zero transcriptional leak explaining the limited signal degradation in the circuits. Our approach enabled the largest, eukaryotic gene circuits to date and will form the basis for large, synthetic, cellular decision-making systems. PMID:28541304
Tracking buoys research for oil spilling with the wireless charging equipment
NASA Astrophysics Data System (ADS)
Cui, Di; Zhao, Ping
2018-03-01
This paper describes thewirelesscharging equipment for achieving oil spill tracking buoys detection in satellite images acquired after tanker accidents or ship oil spill accidents. This information could allow the evolution of residues dumped at sea to be tracked. The validity of this process is demonstrated using several experiment acquired over several regions (Dalian and Tianjin coasts in China), in which a tanker accident has occurred and as a consequence oil spillage has taken place. Thus, this purpose of paper is developed for the active surveillance and rapid response to marine oil spills tracking buoys with wirelesscharging equipmentis important and essential to environment protection. It may appears of leak places for the Wire Charging Equipment for marine oil spills tracking buoys monitoring needs, and achieved instant alarm technology and equipment, guarantees leak occurred timely obtained alarm information. In order toproviding oil spill accidents emergency quickly reaction time and prepared. The maximum degree reduce oil leak and accidents caused influences are ensured.
40 CFR 264.223 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) If the flow rate into the leak detection system exceeds the action leakage rate for any sump, the... action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a... action leakage rate has been exceeded, submit to the Regional Administrator the results of the analyses...
40 CFR 265.303 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... section. (b) If the flow rate into the leak detection system exceeds the action leakage rate for any sump... response action plan must set forth the actions to be taken if the action leakage rate has been exceeded... notification that the action leakage rate has been exceeded, submit to the Regional Administrator the results...
Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks.
Park, Bernard J; Snider, John M; Bates, Nathan R; Cassivi, Stephen D; Jett, G Kimble; Sonett, Joshua R; Toloza, Eric M
2016-12-12
A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. In a multicenter prospective single-arm trial, 112 patients with a median age of 69 years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1 month after surgery for procedure-related and device-related complications and presence of air leak. Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2 days (range 1 - 46 days), and median length of hospitalization was 3 days (range 1 - 20 days). This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. ClinicalTrials.gov: NCT01867658 . Registered 3 May 2013.
Katory, Mark; McLean, Ross; Osman, Khalid; Ahmad, Mukhtar; Hughes, Tracey; Newby, Mike; Dennison, Christopher; O'Loughlin, Paul
2017-02-01
Interpretation of water-soluble contrast enema following laparoscopic low anterior resection can be very challenging for both radiologists and colorectal surgeons. Discriminating the radiological appearances secondary to anastomotic configuration from those caused by actual anastomotic dehiscence is a common problem and may be made worse with the advent of laparoscopic surgery. The aim of this study is to identify potential novel appearances of the water-soluble contrast enema (WSCE) images of rectal anastomosis following laparoscopic low anterior resection to radiologists and surgeons. We enrolled 45 patients who underwent laparoscopic low anterior resection with proximal de-functioning loop ileostomy within a specialized colorectal unit. The water-soluble contrast enema reports were reviewed. Two blinded colorectal radiologists independently reviewed the images of patients suspected of anastomotic leak. All of these patients also underwent a flexible sigmoidoscopy to confirm or exclude anastomotic leak before reversal of loop ileostomy. Inter-observer concordance was calculated. Seven out of eighteen patients (38.9%) were found to have true anastomotic leaks on flexible sigmoidoscopy (15% overall leak rate). In the remaining eleven patients the image appearances were attributed to the appearance of the anastomotic 'dog-ear effect', created by the anastomotic configuration due to multiple firing of the intra-corporeal laparoscopic stapling device. Radiologist inter-observer concordance was 83%. Sensitivity was 100%, specificity 71%, positive-predictive value (38.9%) and negative-predictive value (100%). The novel appearances of laparoscopic-stapled rectal anastomoses in WSCE can be mistaken for anastomotic leak. To avoid delay in reversal of ileostomy, a flexible sigmoidoscopy can be used to confirm or exclude a leak.
Chemical pleurodesis for prolonged postoperative air leak in primary spontaneous pneumothorax.
How, Cheng-Hung; Tsai, Tung-Ming; Kuo, Shuenn-Wen; Huang, Pei-Ming; Hsu, Hsao-Hsun; Lee, Jang-Ming; Chen, Jin-Shing; Lai, Hong-Shiee
2014-05-01
Prolonged air leak is the most common complication after thoracoscopic operation for primary spontaneous pneumothorax (PSP), and the role of chemical pleurodesis in treating air leaks remains unclear. This study evaluated the safety and efficacy of chemical pleurodesis with a comparison between minocycline and OK-432. Between 1994 and 2011, 1083 PSP patients were treated by thoracoscopic operation. After the operation, patients with persistent air leak for 3 days or more were managed by minocycline or OK-432 pleurodesis. The demographic and outcome data for these patients were collected by retrospective chart review. Seventy-nine patients (7.3%) with prolonged air leak after thoracoscopy underwent minocycline pleurodesis (60 patients) or OK-432 pleurodesis (19 patients) as the primary treatment. The primary success rate was 63% (38/60) for minocycline pleurodesis and 95% (18/19) for OK-432 pleurodesis (p = 0.009). Postpleurodesis pain was common and comparable between the two groups. No major complications were noted after a total of 121 treatments. Patients undergoing primary OK-432 pleurodesis had shorter durations of postpleurodesis chest drainage (mean 8.5 vs. 2.3 days; p < 0.001) and postoperative hospital stay (mean 11.9 vs. 6.8 days; p < 0.001) than those undergoing primary minocycline pleurodesis. After a median follow-up of 16 months, recurrence was noted in one patient in the OK-432 group and none in the minocycline group. Long-term pulmonary function in the two groups was comparable. Chemical pleurodesis using OK-432 or minocycline is safe and convenient for prolonged air leak after thoracoscopic treatment for PSP. Our experience suggested that OK-432 may be more effective than minocycline in reducing air leak. Copyright © 2013. Published by Elsevier B.V.
Reilly, Frank; Burke, John P; Appelmans, Eline; Manzoor, Talha; Deasy, Joseph; McNamara, Deborah A
2014-04-01
Anastomotic leak (AL) is a major complication following anterior resection for colorectal cancer. Early contrast enema may diagnose subclinical anastomotic leakage. Knowledge of factors concerning AL is vital to its detection. The aim of this study was to define the incidence, risks and outcome of radiological leak following routine early contrast enema after anterior resection. A cohort of 129 patients who underwent anterior resection for colorectal cancer and had an early Gastrografin enema between July 2008 and December 2012 in a tertiary referral centre was identified from a prospective database. The severity of AL was defined using the International Study Group of Rectal Cancer (ISREC) grading system. Of the 129 patients, 65.1 % were male, and the mean age at surgery was 64.6 ± 1.1 years. Gastrografin enema was performed on average on post-operative day 4.8 ± 0.2. Eighteen patients (14.0 %) had a radiological leak on Gastrografin enema, and nine patients (7.0 %) had a clinical AL. On multivariate analysis, only being of male sex and having a loop ileostomy increased the risk of radiological AL. Gastrografin enema had a sensitivity of 100 % (95 % CI 66-100 %) and specificity of 93 % (95 % CI 86-97 %) for predicting clinical AL. Of the 18 patients with radiological leaks, 11 were ISREC grade A, 3 were grade B and 4 were grade C. In the current series, early Gastrografin enema following anterior resection identifies a 14 % radiological leak rate and has a high sensitivity and specificity for predicting clinical AL. The majority of radiological leaks may be managed conservatively.
Frasson, Matteo; Granero-Castro, Pablo; Ramos Rodríguez, José Luis; Flor-Lorente, Blas; Braithwaite, Mariela; Martí Martínez, Eva; Álvarez Pérez, Jose Antonio; Codina Cazador, Antonio; Espí, Alejandro; Garcia-Granero, Eduardo
2016-01-01
Studies focused on postoperative outcome after oncologic right colectomy are lacking. The main objective was to determine pre-/intraoperative risk factors for anastomotic leak after elective right colon resection for cancer. Secondary objectives were to determine risk factors for postoperative morbidity and mortality. Fifty-two hospitals participated in this prospective, observational study (September 2011-September 2012), including 1102 patients that underwent elective right colectomy. Forty-two pre-/intraoperative variables, related to patient, tumor, surgical procedure, and hospital, were analyzed as potential independent risk factors for anastomotic leak and postoperative morbidity and mortality. Anastomotic leak was diagnosed in 93 patients (8.4 %), and 72 (6.5 %) of them needed radiological or surgical intervention. Morbidity, mortality, and wound infection rates were 29.0, 2.6, and 13.4 %, respectively. Preoperative serum protein concentration was the only independent risk factor for anastomotic leak (p < 0.0001, OR 0.6 per g/dL). When considering only clinically relevant anastomotic leaks, stapled technique (p = 0.03, OR 2.1) and preoperative serum protein concentration (p = 0.004, OR 0.6 g/dL) were identified as the only two independent risk factors. Age and preoperative serum albumin concentration resulted to be risk factors for postoperative mortality. Male gender, pulmonary or hepatic disease, and open surgical approach were identified as risk factors for postoperative morbidity, while male gender, obesity, intraoperative complication, and end-to-end anastomosis were risk factors for wound infection. Preoperative nutritional status and the stapled anastomotic technique were the only independent risk factors for clinically relevant anastomotic leak after elective right colectomy for cancer. Age and preoperative nutritional status determined the mortality risk, while laparoscopic approach reduced postoperative morbidity.
Sammour, T; Cohen, L; Karunatillake, A I; Lewis, M; Lawrence, M J; Hunter, A; Moore, J W; Thomas, M L
2017-11-01
Recently published data support the use of a web-based risk calculator ( www.anastomoticleak.com ) for the prediction of anastomotic leak after colectomy. The aim of this study was to externally validate this calculator on a larger dataset. Consecutive adult patients undergoing elective or emergency colectomy for colon cancer at a single institution over a 9-year period were identified using the Binational Colorectal Cancer Audit database. Patients with a rectosigmoid cancer, an R2 resection, or a diverting ostomy were excluded. The primary outcome was anastomotic leak within 90 days as defined by previously published criteria. Area under receiver operating characteristic curve (AUROC) was derived and compared with that of the American College of Surgeons National Surgical Quality Improvement Program ® (ACS NSQIP) calculator and the colon leakage score (CLS) calculator for left colectomy. Commercially available artificial intelligence-based analytics software was used to further interrogate the prediction algorithm. A total of 626 patients were identified. Four hundred and fifty-six patients met the inclusion criteria, and 402 had complete data available for all the calculator variables (126 had a left colectomy). Laparoscopic surgery was performed in 39.6% and emergency surgery in 14.7%. The anastomotic leak rate was 7.2%, with 31.0% requiring reoperation. The anastomoticleak.com calculator was significantly predictive of leak and performed better than the ACS NSQIP calculator (AUROC 0.73 vs 0.58) and the CLS calculator (AUROC 0.96 vs 0.80) for left colectomy. Artificial intelligence-predictive analysis supported these findings and identified an improved prediction model. The anastomotic leak risk calculator is significantly predictive of anastomotic leak after colon cancer resection. Wider investigation of artificial intelligence-based analytics for risk prediction is warranted.
Fischer, Peter E; Nunn, Andrew M; Wormer, Blair A; Christmas, A Britton; Gibeault, Lindsay A; Green, John M; Sing, Ronald F
2013-12-01
Management of destructive colon injuries during damage control (DC) laparotomy is debated. The authors reviewed a single institution's experience with destructive colon injuries to identify risk factors for anastomotic failure after colon reconstruction. The authors identified all trauma patients sustaining destructive colon injuries between 2002 and 2011 from their medical center's trauma registry. Anastomotic leak was defined as suture or staple line disruption or enteral fistula formation. Of 171 identified patients, 68 had DC procedures, 41 (60%) had subsequent anastomoses performed during the same hospitalization, and 27 (40%) were diverted. The colon anastomotic leak rate in patients who underwent DC laparotomy was higher than in patients who were reconstructed at the primary operation in a non-DC setting (17% vs 6%, P = .09). The use of vasopressors after the initial DC operation more than quadrupled the leak rate to 50% (P = .02). Colonic anastomotic disruptions yield deadly consequences, and diversion rather than anastomosis should be used in patients who require vasopressor support after the initial DC procedure. Copyright © 2013 Elsevier Inc. All rights reserved.
Development and Characterization of an Oro-Nasal Inhalation Plethysmography Mask Exposure System
2016-08-30
209.3 ± 97.37 mL/min. Standardized tests were used to characterize the inhalation exposure system. The fractional leak rate was 4.17 x 10-5 min-1...chloride (Sigma-Aldrich Corp., St. Louis, MO) and W9-1, Ultra Trace Elemental Analysis Water , (Fisher Scientific, Pittsburgh, PA) and placed in the...cylindrical plethysmograph, with an internal volume of 34.9 L, was leak tested as previously described (Mokler and White, 1983). Nonhuman primates
Risks incurred by hydrogen escaping from containers and conduits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swain, M.R.; Grilliot, E.S.
1998-08-01
This paper is a discussion of a method for hydrogen leak classification. Leaks are classified as; gas escapes into enclosed spaces, gas escapes into partially enclosed spaces (vented), and gas escapes into unenclosed spaces. Each of the three enclosure classifications is further divided into two subclasses; total volume of hydrogen escaped and flow rate of escaping hydrogen. A method to aid in risk assessment determination in partially enclosed spaces is proposed and verified for several enclosure geometries. Examples are discussed for additional enclosure geometries.
Science of Water Leaks: Validated Theory for Moisture Flow in Microchannels and Nanochannels.
Lei, Wenwen; Fong, Nicole; Yin, Yongbai; Svehla, Martin; McKenzie, David R
2015-10-27
Water is ubiquitous; the science of its transport in micro- and nanochannels has applications in electronics, medicine, filtration, packaging, and earth and planetary science. Validated theory for water vapor and two-phase water flows is a "missing link"; completing it enables us to define and quantify flow in a set of four standard leak configurations with dimensions from the nanoscale to the microscale. Here we report the first measurements of water vapor flow rates through four silica microchannels as a function of humidity, including under conditions when air is present as a background gas. An important finding is that the tangential momentum accommodation coefficient (TMAC) is strongly modified by surface layers of adsorbed water molecules, in agreement with previous work on the TMAC for nitrogen molecules impacting a silica surface in the presence of moisture. We measure enhanced flow rates for two-phase flows in silica microchannels driven by capillary filling. For the measurement of flows in nanochannels we use heavy water mass spectrometry. We construct the theory for the flow rates of the dominant modes of water transport through each of the four standard configurations and benchmark it against our new measurements in silica and against previously reported measurements for nanochannels in carbon nanotubes, carbon nanopipes, and porous alumina. The findings show that all behavior can be described by the four standard leak configurations and that measurements of leak behavior made using other molecules, such as helium, are not reliable. Single-phase water vapor flow is overestimated by a helium measurement, while two-phase flows are greatly underestimated for channels larger than 100 nm or for all channels when boundary slip applies, to an extent that depends on the slip length for the liquid-phase flows.
Trzcionka, M; Withers, K W; Klingenspor, M; Jastroch, M
2008-06-01
Futile cycling of protons across the mitochondrial inner membrane contributes significantly to standard metabolic rate in a variety of ectothermic and endothermic animals, but adaptations of the mitochondrial bioenergetics to different environmental conditions have rarely been studied in ectotherms. Changes in ambient temperature and nutritional status have a great effect on the physiological demands of ectothermic amphibians and may require the adjustment of mitochondrial efficiency. In order to investigate the effect of temperature and nutritional status on the mitochondrial level, we exposed male cane toads to either 10 degrees C or 30 degrees C and fasted half of the animals in each group. Cold exposure resulted in a fourfold reduction of the resting metabolic rate whereas nutritional status had only minor effects. The mitochondrial adjustments to each condition were observed by comparing the proton leak kinetics of isolated liver and skeletal muscle mitochondria at 25 degrees C. In response to cold exposure, liver mitochondria showed a decrease in proton conductance while skeletal muscle mitochondria were unchanged. Additional food deprivation had minor effects in skeletal muscle, but in liver we uncovered surprising differences in energy saving mechanisms between the acclimation temperatures: in warm-acclimated toads, fasting resulted in a decrease of the proton conductance whereas in cold-acclimated toads, the activity of the respiratory chain was reduced. To investigate the molecular mechanism underlying mitochondrial proton leakage, we determined the adenine-nucleotide transporter (ANT) content, which explained tissue-specific differences in the basal proton leak, but neither the ANT nor uncoupling protein (UCP) gene expression correlated with alterations of the proton leak in response to physiological stimuli.
Armstrong, G; Croft, J; Corrigan, N; Brown, J M; Goh, V; Quirke, P; Hulme, C; Tolan, D; Kirby, A; Cahill, R; O'Connell, R; Miskovic, D; Coleman, M; Jayne, D G
2018-05-11
Anastomotic leak (AL) is a major complication of rectal cancer surgery. Despite advances in surgical practice, rates of AL have remained static at around 10-15%. The aetiology of AL is multifactorial, but one of the most crucial risk factors, which is mostly under the control of the surgeon, is blood supply to the anastomosis. The MRC/NIHR IntAct study will determine whether assessment of anastomotic perfusion using a fluorescent dye (Indocyanine Green) and near-infrared laparoscopy can minimise the rate of anastomotic leak as compared to conventional white light laparoscopy. Two mechanistic sub-studies will explore the role of the rectal microbiome in AL and the predictive value of CT angiography/perfusion studies. IntAct is a prospective, unblinded, parallel group, multicentre, European, randomised controlled trial comparing surgery with intraoperative fluorescence angiography (IFA) against standard care (surgery with no IFA). The primary end-point is rate of clinical anastomotic leak at 90-days following surgery. Secondary endpoints include all AL (clinical and radiological), change in planned anastomosis, complications and re-interventions, use of stoma, cost effectiveness of the intervention and quality of life. Patients should have a diagnosis of adenocarcinoma of the rectum suitable for potentially curative surgery by anterior resection. Over three years, 880 patients from 25 European centres will be recruited and followed up for 90 days. IntAct will rigorously evaluate the use of IFA in rectal cancer surgery and explore the role of the microbiome in AL and the predictive value of preoperative CT angiography/perfusion scanning. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Large-Scale Liquid Hydrogen Testing of Variable Density Multilayer Insulation with a Foam Substrate
NASA Technical Reports Server (NTRS)
Martin, J. J.; Hastings, L.
2001-01-01
The multipurpose hydrogen test bed (MHTB), with an 18-cu m liquid hydrogen tank, was used to evaluate a combination foam/multilayer combination insulation (MLI) concept. The foam element (Isofoam SS-1171) insulates during ground hold/ascent flight, and allowed a dry nitrogen purge as opposed to the more complex/heavy helium purge subsystem normally required. The 45-layer MLI was designed for an on-orbit storage period of 45 days. Unique WI features include a variable layer density, larger but fewer double-aluminized Mylar perforations for ascent to orbit venting, and a commercially established roll-wrap installation process that reduced assembly man-hours and resulted in a roust, virtually seamless MLI. Insulation performance was measured during three test series. The spray-on foam insulation (SOFI) successfully prevented purge gas liquefaction within the MLI and resulted in the expected ground hold heat leak of 63 W/sq m. The orbit hold tests resulted in heat leaks of 0.085 and 0.22 W/sq m with warm boundary temperatures of 164 and 305 K, respectively. Compared to the best previously measured performance with a traditional MLI system, a 41-percent heat leak reduction with 25 fewer MLI layers was achieved. The MHTB MLI heat leak is half that calculated for a constant layer density MLI.
Covered self-expandable metal stents for benign biliary tract diseases.
Baron, Todd H
2011-05-01
Benign biliary diseases are often managed endoscopically using plastic stents. Benign biliary strictures (BBS) respond to placement of multiple large-bore plastic stents, though requiring multiple procedures to place stents, and to exchange stents to prevent and/or treat stent occlusion. Bile leaks close using plastic stents, which divert bile away from the leak into the duodenum. Covered self-expandable metal stents (CSEMS), intended for palliation of malignant biliary obstruction, have been used to treat benign biliary diseases. Advantages include small predeployment and large postexpansion diameters. Lack of imbedding of the metal into the bile duct wall enables removability. For strictures, one CSEMS is inserted without need for dilation and remains in place for up to 6 months. Successful removal has been reported in all cases. Long-term stricture resolution is achieved in up to 92%. Adverse events include migration and new stricture formation. For treatment of complex bile leaks, the covering and large diameter allow successful closure in nearly all cases. Other uses of CSEMS include treatment of postsphincterotomy bleeding and closure of perforations. CSEMS show promise for treatment of BBS and complex biliary leaks. Successful resolution can be achieved in the majority of patients with the advantage of fewer procedures, which offsets their higher cost.
GPR image analysis to locate water leaks from buried pipes by applying variance filters
NASA Astrophysics Data System (ADS)
Ocaña-Levario, Silvia J.; Carreño-Alvarado, Elizabeth P.; Ayala-Cabrera, David; Izquierdo, Joaquín
2018-05-01
Nowadays, there is growing interest in controlling and reducing the amount of water lost through leakage in water supply systems (WSSs). Leakage is, in fact, one of the biggest problems faced by the managers of these utilities. This work addresses the problem of leakage in WSSs by using GPR (Ground Penetrating Radar) as a non-destructive method. The main objective is to identify and extract features from GPR images such as leaks and components in a controlled laboratory condition by a methodology based on second order statistical parameters and, using the obtained features, to create 3D models that allows quick visualization of components and leaks in WSSs from GPR image analysis and subsequent interpretation. This methodology has been used before in other fields and provided promising results. The results obtained with the proposed methodology are presented, analyzed, interpreted and compared with the results obtained by using a well-established multi-agent based methodology. These results show that the variance filter is capable of highlighting the characteristics of components and anomalies, in an intuitive manner, which can be identified by non-highly qualified personnel, using the 3D models we develop. This research intends to pave the way towards future intelligent detection systems that enable the automatic detection of leaks in WSSs.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653
The high energy demand of neuronal cells caused by passive leak currents is not a waste of energy.
Berndt, Nikolaus; Holzhütter, Hermann-Georg
2013-11-01
It is estimated that maintenance of the resting potential of neurons consumes between 15% (in gray matter) and 44% (in fully myelinated white matter) of the brain's total energy budget [1]. This poses the intriguing question why evolution has not strived to lower the permeability of passive ion channels to cut the high resting-state energy budget of the brain. Based on a conceptual mathematical model of neuronal ion currents and action potential (AP) firing we demonstrate that a neuron endowed with small leak currents and correspondingly low energy consumption by the Na(+)/K(+)-ATPase in the resting state may indeed recapitulate all features of normal AP firing. However, the activation and inactivation of such a "low-energy-cost neuron" turns out to be extremely sensitive to small fluctuation of Na(+) currents associated with Na(+)-dependent secondary-active transport that is indispensable for the metabolic integrity of the cell and neurotransmitter recycling. We provide evidence that sufficiently large leak currents function as important stabilizers of the membrane potential and thus are required to allow robust AP firing. Our simulations suggest that the energy demand of the Na(+)/K(+)-ATPase needed to counterbalance passive leak currents cannot be significantly dropped below observed values.
40 CFR 60.482-9 - Standards: Delay of repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
... destroyed or recovered in a control device complying with § 60.482-10. (d) Delay of repair for pumps will be... allowed for a leaking pump or valve that remains in service, the pump or valve may be considered to be...
40 CFR 60.482-9 - Standards: Delay of repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
... destroyed or recovered in a control device complying with § 60.482-10. (d) Delay of repair for pumps will be... allowed for a leaking pump or valve that remains in service, the pump or valve may be considered to be...
40 CFR 60.482-9 - Standards: Delay of repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
... destroyed or recovered in a control device complying with § 60.482-10. (d) Delay of repair for pumps will be... allowed for a leaking pump or valve that remains in service, the pump or valve may be considered to be...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2013 CFR
2013-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2012 CFR
2012-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2014 CFR
2014-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
NASA Astrophysics Data System (ADS)
Weller, Z.; Hoeting, J.; von Fischer, J.
2017-12-01
Pipeline systems that distribute natural gas (NG) within cities can leak, leading to safety hazards and wasted product. Moreover, these leaks are climate-altering because NG is primarily composed of methane, a potent greenhouse gas. Scientists have recently developed an innovative method for mapping NG leak locations by installing atmospheric methane analyzers on Google Street View cars. We develop new statistical methodology to answer key inferential questions using data collected by these mobile air monitors. The new calibration-capture-recapture (CCR) model utilizes data from controlled methane releases and data collected by GSV cars to provide inference for several desired quantities, including the number of undetected methane sources and the total methane output rate in a surveyed region. The CCR model addresses challenges associated with using a capture-recapture model to analyze data collected by a mobile detection system including variable sampling effort and lack of physically marking individuals. We develop a Markov chain Monte Carlo algorithm for parameter estimation and apply the CCR model to methane data collected in two U.S. cities. The CCR model provides a new framework for inferring the total number of leaks in NG distribution systems and offers critical insights for informing intelligent repair policy that is both cost-effective and environmentally friendly.
Chest tube management following pulmonary lobectomy: change of protocol results in fewer air leaks.
Bertholet, Joost W M; Joosten, Joris J A; Keemers-Gels, Mariël E; van den Wildenberg, Frits J H; Barendregt, Wouter B
2011-01-01
Much controversy exists regarding the management of chest tubes following pulmonary lobectomy. The objective of this study was to analyse the effect of a new chest tube management protocol on clinical features, such as postoperative air leak, drain characteristics, 30-day postoperative complications and length of hospital stay. We retrospectively analysed 133 patients who underwent pulmonary lobectomy, from January 2005 to December 2008. A new chest tube protocol was introduced on 1 January 2007 and included placement of a single chest tube and early conversion to water seal. The chest tube was removed when air leak had resolved and (non-chylous) fluid drainage was <400 ml/day. The results of patients in the old (n=68) and the new protocol (n=65) were compared. In the new protocol group the median duration of air leak and duration of chest tube drainage declined significantly. Also the length of hospital stay decreased significantly to a median of eight days. The number of reinterventions and 30-day morbidity and mortality rates did not differ significantly. Our data suggest that placement of a single chest tube and early conversion to water seal decreases the duration of air leak and chest tube drainage and length of hospital stay.
Influence of multiple stapler firings used for rectal division on colorectal anastomotic leak rate.
Braunschmid, Tamara; Hartig, Nikolaus; Baumann, Lukas; Dauser, Bernhard; Herbst, Friedrich
2017-12-01
Anastomotic leakage following colorectal resection remains one of the most significant complications with relevant morbidity and mortality. There is evidence that a higher number of stapler firings for rectal division can affect the leak rate in double stapling anastomosis. However, there are no data concerning compression anastomosis. We present our institutional experience addressing this issue. This is a retrospective review of a prospective institutional database of patients undergoing colonic and rectal resection for benign and malignant indications between January 2008 and December 2014 at the surgical department of the St. John of God Hospital, Vienna. Inclusion criteria were rectal division with linear stapling devices and construction of anastomosis to the rectal stump using a circular stapler or compression device. Three hundred eighty two (196 female; 51.3%) patients were included. Mean age was 65.8 years (range: 18-95) Indications for the operation included diverticular disease (44.8%), colorectal carcinoma (51.6%), inflammatory bowel disease (1.8%), and adenoma (1.8%). A laparoscopic approach was employed in 334 cases (87.4%); in 170 patients (44.9%), a compression anastomosis was created. One, two, and three or more stapler cartridges were used for rectal division in 58.4, 33.5, and 8.1%, respectively. Male gender, neoadjuvant therapy, rectal cancer as an underlying disease, laparoscopic surgical approach, and duration of operation longer than 200 min are leading causes for the usage of more than one stapler cartridge. Overall leak rate was 4.7% (18/382). The only factor associated with the occurrence of leakage was the use of three or more stapler cartridges for the closure of the rectal stump (p = 0.002). Our data support that multiple stapler firings for rectal division following colorectal resection has a major impact on anastomotic leak rate. Especially in laparoscopic surgery efforts should be made to minimize the number of stapler cartridges used.
Lei, Wenwen; Rigozzi, Michelle K; McKenzie, David R
2016-02-01
This review assesses the current state of understanding of the calculation of the rate of flow of gases, vapours and liquids confined in channels, in porous media and in permeable materials with an emphasis on the flow of water and its vapour. One motivation is to investigate the relation between the permeation rate of moisture and that of a noncondensable test gas such as helium, another is to assist in unifying theory and experiment across disparate fields. Available theories of single component ideal gas flows in channels of defined geometry (cylindrical, rectangular and elliptical) are described and their predictions compared with measurement over a wide range of conditions defined by the Knudsen number. Theory for two phase flows is assembled in order to understand the behaviour of four standard water leak configurations: vapour, slug, Washburn and liquid flow, distinguished by the number and location of phase boundaries (menisci). Air may or may not be present as a background gas. Slip length is an important parameter that greatly affects leak rates. Measurements of water vapour flows confirm that water vapour shows ideal gas behaviour. Results on carbon nanotubes show that smooth walls may lead to anomalously high slip lengths arising from the properties of 'confined' water. In porous media, behaviour can be matched to the four standard leaks. Traditional membrane permeation models consider that the permeant dissolves, diffuses and evaporates at the outlet side, ideas we align with those from channel flow. Recent results on graphite oxide membranes show examples where helium which does not permeate while at the same time moisture is almost unimpeded, again a result of confined water. We conclude that while there is no a priori relation between a noncondensable gas flow and a moisture flow, measurements using helium will give results within two orders of magnitude of the moisture flow rate, except in the case where there is anomalous slip or confined water, when moisture specific measurements are essential.
Acoustic measurement of the Deepwater Horizon Macondo well flow rate
Camilli, Richard; Di Iorio, Daniela; Bowen, Andrew; Reddy, Christopher M.; Techet, Alexandra H.; Yoerger, Dana R.; Whitcomb, Louis L.; Seewald, Jeffrey S.; Sylva, Sean P.; Fenwick, Judith
2012-01-01
On May 31, 2010, a direct acoustic measurement method was used to quantify fluid leakage rate from the Deepwater Horizon Macondo well prior to removal of its broken riser. This method utilized an acoustic imaging sonar and acoustic Doppler sonar operating onboard a remotely operated vehicle for noncontact measurement of flow cross-section and velocity from the well’s two leak sites. Over 2,500 sonar cross-sections and over 85,000 Doppler velocity measurements were recorded during the acquisition process. These data were then applied to turbulent jet and plume flow models to account for entrained water and calculate a combined hydrocarbon flow rate from the two leak sites at seafloor conditions. Based on the chemical composition of end-member samples collected from within the well, this bulk volumetric rate was then normalized to account for contributions from gases and condensates at initial leak source conditions. Results from this investigation indicate that on May 31, 2010, the well’s oil flow rate was approximately 0.10 ± 0.017 m3 s-1 at seafloor conditions, or approximately 85 ± 15 kg s-1 (7.4 ± 1.3 Gg d-1), equivalent to approximately 57,000 ± 9,800 barrels of oil per day at surface conditions. End-member chemical composition indicates that this oil release rate was accompanied by approximately an additional 24 ± 4.2 kg s-1 (2.1 ± 0.37 Gg d-1) of natural gas (methane through pentanes), yielding a total hydrocarbon release rate of 110 ± 19 kg s-1 (9.5 ± 1.6 Gg d-1). PMID:21903931
Otteni, J C; Beydon, L; Cazalaà, J B; Feiss, P; Nivoche, Y
1997-01-01
To review anaesthesia ventilators in current use in France by categories of ventilators. References were obtained from computerized bibliographic search. (Medline), recent review articles, the library of the service and personal files. Anaesthesia ventilators can be allocated into three groups, depending on whether they readminister expired gases or not or allow both modalities. Contemporary ventilators provide either constant volume ventilation, or constant pressure ventilation, with or without a pressure plateau. Ventilators readministering expired gases after CO2 absorption, or closed circuit ventilators, are either of a double- or a single-circuit design. Double-circuit ventilators, or pneumatical bag or bellows squeezers, or bag-in-bottle or bellows-in-bottle (or box) ventilators, consist of a primary, or driving circuit (bottle or box) and a secondary or patient circuit (including a bag or a bellows or membrane chambers). Bellows-in-bottle ventilators have either standing bellows ascending at expiration, or hanging bellows, descending at expiration. Ascending bellows require a positive pressure of about 2 cmH2O throughout exhalation to allow the bellows to refill. The expired gas volume is a valuable indicator for leak and disconnection. Descending bellows generate a slight negative pressure during exhalation. In case of leak or disconnection they aspirate ambient air and cannot act therefore as an indicator for integrity of the circuit and the patient connection. Closed circuit ventilators with a single-circuit (patient circuit) include a insufflating device consisting either in a bellows or a cylinder with a piston, operated by a electric or pneumatic motor. As the hanging bellows of the double circuit ventilators, they generate a slight negative pressure during exhalation and aspirate ambient air in case of leak or disconnection. Ventilators not designed for the readministration of expired gases, or open circuit ventilators, are generally stand-alone mechanical ventilators modified to allow the administration of inhalational anaesthetic agents.
Standard outcome indicators after colon cancer resection. Creation of a nomogram for autoevaluation.
Sancho-Muriel, Jorge; Frasson, Matteo; Hervás, David; Flor-Lorente, Blas; Ramos Rodriguez, José Luis; Romero Simó, Manuel; Escoll Rufino, Jordi; Santamaría Olabarrieta, Marta; Viñas Martinez, José; López Bañeres, Manolo; García-Granero, Eduardo
2017-01-01
Lately there has been an increasing interest in identifying quality standards in different pathologies, among them colon cancer due to its great prevalence. The main goal of this study is to define the quality standards of colon cancer surgery based on a large prospective national study dataset. Data from the prospective national study ANACO were used. This study included a consecutive series of patients operated on for colon cancer in 52 Spanish hospitals (2011-2012). Centers with less than 30 patients were excluded. The present analysis finally included 42 centers (2975 patients). Based on the results obtained in 4main indicators from each hospital (anastomotic leak, lymph-nodes found in the specimen, mortality and length of stay), a nomogram that allows the evaluation of the performance of each center was designed. Standard results for further 5 intraoperative and 5 postoperative quality indicators were also reported. Median of anastomotic leak and mortality rate was 8.5% (25 th -75 th percentiles 6.1%-12.4%) and 2.5% (25 th -75 th percentiles 0.6%-4.7%), respectively. Median number of nodes found in the surgical specimen was 15,1 (25 th -75 th percentiles 18-14 nodes). Median length of postoperative stay was 7.7 days (25 th -75 th percentiles 6.9-9.2 days). Based on these data, a nomogram for hospital audit was created. Standard surgical results after colon cancer surgery were defined, creating a tool for auto-evaluation and allowing each center to identify areas for improvement in the surgical treatment of colon cancer. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Robin, Gaëlle; Berthier, Christine
2012-01-01
Under resting conditions, external Ca2+ is known to enter skeletal muscle cells, whereas Ca2+ stored in the sarcoplasmic reticulum (SR) leaks into the cytosol. The nature of the pathways involved in the sarcolemmal Ca2+ entry and in the SR Ca2+ leak is still a matter of debate, but several lines of evidence suggest that these Ca2+ fluxes are up-regulated in Duchenne muscular dystrophy. We investigated here SR calcium permeation at resting potential and in response to depolarization in voltage-controlled skeletal muscle fibers from control and mdx mice, the mouse model of Duchenne muscular dystrophy. Using the cytosolic Ca2+ dye Fura2, we first demonstrated that the rate of Ca2+ increase in response to cyclopiazonic acid (CPA)–induced inhibition of SR Ca2+-ATPases at resting potential was significantly higher in mdx fibers, which suggests an elevated SR Ca2+ leak. However, removal of external Ca2+ reduced the rate of CPA-induced Ca2+ increase in mdx and increased it in control fibers, which indicates an up-regulation of sarcolemmal Ca2+ influx in mdx fibers. Fibers were then loaded with the low-affinity Ca2+ dye Fluo5N-AM to measure intraluminal SR Ca2+ changes. Trains of action potentials, chloro-m-cresol, and depolarization pulses evoked transient Fluo5N fluorescence decreases, and recovery of voltage-induced Fluo5N fluorescence changes were inhibited by CPA, demonstrating that Fluo5N actually reports intraluminal SR Ca2+ changes. Voltage dependence and magnitude of depolarization-induced SR Ca2+ depletion were found to be unchanged in mdx fibers, but the rate of the recovery phase that followed depletion was found to be faster, indicating a higher SR Ca2+ reuptake activity in mdx fibers. Overall, CPA-induced SR Ca2+ leak at −80 mV was found to be significantly higher in mdx fibers and was potentiated by removal of external Ca2+ in control fibers. The elevated passive SR Ca2+ leak may contribute to alteration of Ca2+ homeostasis in mdx muscle. PMID:22371362
Quality Improvement Initiatives in Colorectal Surgery: Value of Physician Feedback.
Waters, Joshua A; Francone, Todd; Marcello, Peter W; Roberts, Patricia L; Schoetz, David J; Read, Thomas E; Stafford, Caitlin; Ricciardi, Rocco
2017-02-01
The impact of process improvement through surgeon feedback on outcomes is unclear. We sought to evaluate the effect of biannual surgeon-specific feedback on outcomes and adherence to departmental and Surgical Care Improvement Project process measures on colorectal surgery outcomes. This was a retrospective analysis of prospectively collected 100% capture surgical quality improvement data. This study was conducted at the department of colorectal surgery at a tertiary care teaching hospital from January 2008 through December 2013. Each surgeon was provided with biannual feedback on process adherence and surgeon-specific outcomes of urinary tract infection, deep vein thrombosis, surgical site infection, anastomotic leak, 30-day readmission, reoperation, and mortality. We recorded adherence to Surgical Care Improvement Project process measures and departmentally implemented measures (ie, anastomotic leak testing) as well as surgeon-specific outcomes. We abstracted 7975 operations. There was no difference in demographics, laparoscopy, or blood loss. Adherence to catheter removal increased from 73% to 100% (p < 0.0001), whereas urinary tract infection decreased 52% (p < 0.01). Adherence to thromboprophylaxis administration remained unchanged as did the deep vein thrombosis rate (p = not significant). Adherence to preoperative antibiotic administration increased from 72% to 100% (p < 0.0001), whereas surgical site infection did not change (7.6%-6.6%; p = 0.3). There were 2589 operative encounters with anastomoses. For right-sided anastomoses, the proportion of handsewn anastomoses declined from 19% to 1.5% (p < 0.001). For left-sided anastomoses, without diversion, anastomotic leak testing adherence increased from 88% to 95% (p < 0.01). Overall leak rate decreased from 5.2% to 2.9% (p < 0.05). Concurrent process changes make isolation of the impact from individual process improvement changes challenging. Nearly complete adherence to process measures for deep vein thrombosis and surgical site infection did not lead to measureable outcomes improvement. Process measure adherence was associated with decreased rate of anastomotic leak and urinary tract infection. Biannual surgeon-specific feedback of outcomes was associated with improved process measure adherence and improvement in surgical quality.
NASA Technical Reports Server (NTRS)
Underwood, Steve; Lvovsky, Oleg
2007-01-01
The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology. However, this technology is capable of bringing the air leakage of a building that was built with standard construction techniques and HERS-verified sealing down to levels that would meet DOE Zero Energy Ready Homes program requirements. When a developer is striving to meet a tighter envelope leakage specification, this technology could greatly reduce the cost to achieve that goal by providing a simple and relatively low cost method for reducing the air leakage of a building envelope with little to no change in their common building practices.« less
DOT National Transportation Integrated Search
2017-01-01
Concrete cracking, high permeability, and leaking joints allow for intrusion of harmful solutions, resulting in concrete deterioration and corrosion of reinforcement in structures. The development of durable, high-performance concretes with limited c...
Gross, K.C.
1994-07-26
Failure of a fuel element in a nuclear reactor core is determined by a gas tagging failure detection system and method. Failures are catalogued and characterized after the event so that samples of the reactor's cover gas are taken at regular intervals and analyzed by mass spectroscopy. Employing a first set of systematic heuristic rules which are applied in a transformed node space allows the number of node combinations which must be processed within a barycentric algorithm to be substantially reduced. A second set of heuristic rules treats the tag nodes of the most recent one or two leakers as background'' gases, further reducing the number of trial node combinations. Lastly, a fuzzy'' set theory formalism minimizes experimental uncertainties in the identification of the most likely volumes of tag gases. This approach allows for the identification of virtually any number of sequential leaks and up to five simultaneous gas leaks from fuel elements. 14 figs.
NASA Astrophysics Data System (ADS)
Alden, Caroline B.; Ghosh, Subhomoy; Coburn, Sean; Sweeney, Colm; Karion, Anna; Wright, Robert; Coddington, Ian; Rieker, Gregory B.; Prasad, Kuldeep
2018-03-01
Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model-data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10-5 kg s-1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1σ), when measurements are averaged over 2 min. The results of the synthetic and field data testing show that the new observing system and statistical approach greatly decreases the incidence of false alarms (that is, wrongly identifying a well site to be leaking) compared with the same tests that do not use the NZMB approach and therefore offers increased leak detection and sizing capabilities.
Humayun, Md Tanim; Divan, Ralu; Stan, Liliana; ...
2016-06-16
This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH 4) sensor system (DMSS) for continuous monitoring, detection, and localization of CH 4 leaks in natural gas infrastructure, such as transmission and distribution pipelines, wells, and production pads. The CH 4 sensing element, a key component of the DMSS, consists of a metal oxide nanocrystal (MONC) functionalized multi-walled carbon nanotube (MWCNT) mesh which, in comparison to existing literature, shows stronger relative resistance change while interacting with lower parts per million (ppm) concentration of CH 4. A Gaussian plume triangulation algorithm has been developed for the DMSS. Givenmore » a geometric model of the surrounding environment the algorithm can precisely detect and localize a CH 4 leak as well as estimate its mass emission rate. A UV-based surface recovery technique making the sensor recover 10 times faster than the reported ones is presented for the DMSS. In conclusion, a control algorithm based on the UV-accelerated recovery is developed which facilitates faster leak detection.« less
Evaluating All-Metal Valves for Use in a Tritium Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houk, L.; Payton, A.
In the tritium gas processing system, it is desired to minimize polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in the tritium process is valve components. A vendor has been identified that manufactures a valve that is marketed as being made from all-metal construction. This manufacturer, Ham-Let Group, manufactures a diaphragm valve (3LE series) that claims to be made entirely of metal. SRNL procured twelve (12) Ham-Let diaphragm valves for characterization and evaluation. The characterization tests include identification of the maximum pressure of these valves by performing pressure and burst tests. Leak testsmore » were performed to ensure the valves do not exceed the acceptable leak rate for tritium service. These valves were then cycled in a nitrogen gas and/or vacuum environment to ensure they would be durable in a process environment. They were subsequently leak tested per ASTM protocol to ensure that the valves maintained their leak tight integrity. A detailed material analysis was also conducted to determine hydrogen and tritium compatibility.« less
Calculation note for an underground leak which remains underground
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, H.J.
1997-05-20
This calculation note supports the subsurface leak accident scenario which remains subsurface. It is assumed that a single walled pipe carrying waste from tank 106-C ruptures, releasing the liquid waste into the soil. In this scenario, the waste does not form a surface pool, but remains subsurface. However, above the pipe is a berm, 0.762 m (2.5 ft) high and 2.44 m (8 ft) wide, and the liquid released from the leak rises into the berm. The slurry line, which transports a source term of higher activity than the sluice line, leaks into the soil at a rate of 5%more » of the maximum flow rate of 28.4 L/s (450 gpm) for twelve hours. The dose recipient was placed a perpendicular distance of 100 m from the pipe. Two source terms were considered, mitigated and unmitigated release as described in section 3.4.1 of UANF-SD-WM-BIO-001, Addendum 1. The unmitigated consisted of two parts of AWF liquid and one part AWF solid. The mitigated release consisted of two parts SST liquid, eighteen parts AWF liquid, nine parts SST solid, and one part AWF solid. The isotopic breakdown of the release in these cases is presented. Two geometries were considered in preliminary investigations, disk source, and rectangular source. Since the rectangular source results from the assumption that the contamination is wicked up into the berm, only six inches of shielding from uncontaminated earth is present, while the disk source, which remains six inches below the level of the surface of the land is often shielded by a thick shield due to the slant path to the dose point. For this reason, only the rectangular source was considered in the final analysis. The source model was a rectangle 2.134 m (7 ft) thick, 0.6096 m (2 ft) high, and 130.899 m (131 ft) long. The top and sides of this rectangular source was covered with earth of density 1.6 g/cm{sup 3} to a thickness of 15.24 cm (6 in). This soil is modeled as 40% void space. The source consisted of earth of the same density with the void spaces filled with the liquid waste which added 0.56 g/cm{sup 3} to the density. The dose point was 100 m (328 ft) away from the berm in a perpendicular direction off the center. The computer code MICROSKYSHINEO was used to calculate the skyshine from the source. This code calculates exposure rate at the receptor point. The photon spectrum from 2 MeV to 0.15 MeV, obtained from ISOSHLD, was used as input, although this did not differ substantially from the results obtained from using Co, 137mBa, and 154Eu. However, this methodology allowed the bremsstrahlung contribution to be included in the skyshine calculation as well as in the direct radiation calculation.« less
Hydrogen leak detection in the Space Shuttle
NASA Technical Reports Server (NTRS)
Barile, Ronald G
1992-01-01
This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter, jet velocity, sample tube design, radial effects, vertical flow, and low hydrogen concentrations (1 percent). A frequent observation was that the power spectrum, calculated from the Fourier transform of concentration fluctuations, gives a separate piece of information from concentration. Many of the tests suggest that power is high where mixing occurs at the helium-air interface. This fact is apparently independent of the concentration level, which could be high or low, but depends on the sample location relative to the jet (leak) origin, whereas high concentration may be due to a strong leak far away or a small leak close to the sample tube. If the power is low for any concentration level, this would signify helium is arriving at the sample tube by diffusion, not chaotic mixing caused by the jet interaction with air. The practical result is to propose a modification of the HGDL mass spectrometer data sampling and software so that sampling rates could be capable of observing at least 25 Hz fluctuations.
Bezagu, Marine; Clarhaut, Jonathan; Renoux, Brigitte; Monti, Fabrice; Tanter, Mickael; Tabeling, Patrick; Cossy, Janine; Couture, Olivier; Papot, Sebastien; Arseniyadis, Stellios
2017-12-15
The efficiency of a drug is usually highly dependent on the way it is administered or delivered. As such, targeted-therapy, which requires conceiving drug-delivery vehicles that will change their state from a relatively stable structure with a very slow leak-rate to an unstable structure with a fast release, clearly improves the pharmacokinetics, the absorption, the distribution, the metabolism and the therapeutic index of a given drug. In this context, we have developed a particularly effective double stimuli-responsive drug-delivery method allowing an ultrasound-induced release of a monomethylauristatin E-glucuronide prodrug and its subsequent activation by a β-glucuronidase. This led to an increase of cytotoxicity of about 80% on cancer cells. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Gowers, S. A. N.; Hamaoui, K.; Cunnea, P.; Anastasova, S.; Curto, V. F.; Vadgama, P.; Yang, G.-Z.; Papalois, V.; Drakakis, E. M.; Fotopoulou, C.; Weber, S. G.
2018-01-01
This paper presents the use of tubing to store clinical microdialysis samples for delayed analysis with high temporal resolution, offering an alternative to traditional discrete offline microdialysis sampling. Samples stored in this way were found to be stable for up to 72 days at –80 °C. Examples of how this methodology can be applied to glucose and lactate measurement in a wide range of in vivo monitoring experiments are presented. This paper presents a general model, which allows for an informed choice of tubing parameters for a given storage time and flow rate avoiding high back pressure, which would otherwise cause the microdialysis probe to leak, while maximising temporal resolution. PMID:29336454
Park, Jae Kil; Moon, Seok Whan
2017-01-01
Background Anastomotic leak is one of most significant causes of mortality after esophagectomy. Therefore, it is clinically valuable to detect anastomotic leak early after esophagectomy in esophageal cancer. The purpose of this study is to investigate the associations between routine postoperative laboratory findings and anastomotic leak and to analyze the laboratory findings to find out an independent predictive marker for anastomotic leak. In addition, this study compares cases treated with neoadjuvant therapy (NT) and those without (non-NT). Methods We retrospectively assessed the medical records of 201 consecutive cases that met this study’s criteria from January 2009 to December 2016. All patients underwent curative and complete esophagectomy for intra-thoracic esophageal cancer. We compiled and analyzed routine laboratory findings from the day before surgery to the eighth postoperative day on a daily basis. Routine laboratory tests consisted of 26 separate tests, including complete blood cell counts, blood chemistries, as well as erythrocyte sedimentation rate and C-reactive protein (CRP). Barium esophagogram with chest computed tomography (CT) was performed on the seventh postoperative day to evaluate the presence of an anastomotic leak. Results A total of 45 of 201 patients underwent NT. Anastomotic leaks were found in 23 (11.4%) of 201 patients (8 patients in NT and 15 patients in non-NT). White blood cell (WBC) from the second postoperative day (P=0.031, P=0.006, P=0.007, P=0.007, P=0.041, and P=0.003, respectively) and CRP from the third postoperative day (P=0.012, P<0.001, P=0.014, P<0.001, P=0.001, and P=0.006, respectively) were associated with anastomotic leak in non-NT; however, only CRP on the third, fifth, sixth, and seventh postoperative days (P=0.041, P=0.037, P=0.002, and P=0.003, respectively) was associated with anastomotic leak in NT. The CRP level on the third postoperative day was a significant independent predictive marker of anastomotic leak (P=0.041, odd ratio (OR) 1.056, 95% confidential interval (CI): 1.002–1.113) and had a significant diagnostic cutoff value for the development of anastomotic leak (non-NT: cutoff value 17.12 mg/dL, sensitivity 69.2%, specificity 78.1%, P<0.001, area 0.822; NT: cutoff value 16.42 mg/dL, sensitivity 80.0%, specificity 70.0%, P=0.042, area 0.7104). Conclusions There were divergent laboratory findings reflective of anastomotic leak between patients who underwent NT and those who did not. The CRP level on the third postoperative day had a significant cutoff value for early detection of anastomotic leak after esophagectomy in both NT and non-NT groups. PMID:29268376
SIXTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2011-08-31
A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for seven years at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues formore » 33 GLT O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 F and higher temperatures, and in 7 fixtures aging at 300 F. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 41-60 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 F will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging within the past year at an intermediate temperature of 270 F, with hopes that they may leak before the 200 F fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200-300 F for up to 26 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-96%. This is greater than seen to date for packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350-400 F). However, at 300 F, the room temperature leak test failures to date experienced longer aging times than predicted by the CSR-based model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 F will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.« less
Kubicka, Zuzanna J; Limauro, Joseph; Darnall, Robert A
2008-01-01
The goal was to estimate the level of delivered continuous positive airway pressure by measuring oral cavity pressure with the mouth closed in infants of various weights and ages treated with heated, humidified high-flow nasal cannula at flow rates of 1-5 L/minute. We hypothesized that clinically relevant levels of continuous positive airway pressure would not be achieved if a nasal leak is maintained. After performing bench measurements and demonstrating that oral cavity pressure closely approximated levels of traditionally applied nasal continuous positive airway pressure, we successfully measured oral cavity pressure during heated, humidified, high-flow nasal cannula treatment in 27 infants. Small (outer diameter: 0.2 cm) cannulae were used for all infants, and flow rates were left as ordered by providers. Bench measurements showed that, for any given leak size, there was a nearly linear relationship between flow rate and pressure. The highest pressure achieved was 4.5 cmH2O (flow rate: 8 L/minute; leak: 3 mm). In our study infants (postmenstrual age: 29.1-44.7 weeks; weight: 835-3735 g; flow rate: 1-5 L/minute), no pressure was generated with the mouth open at any flow rate. With the mouth closed, the oral cavity pressure was related to both flow rate and weight. For infants of < or = 1500 g, there was a linear relationship between flow rate and oral cavity pressure. Oral cavity pressure can estimate the level of continuous positive airway pressure. Continuous positive airway pressure generated with heated, humidified, high-flow nasal cannula treatment depends on the flow rate and weight. Only in the smallest infants with the highest flow rates, with the mouth fully closed, can clinically significant but unpredictable levels of continuous positive airway pressure be achieved. We conclude that heated, humidified high-flow nasal cannula should not be used as a replacement for delivering continuous positive airway pressure.
The use of image-guidance during transsphenoidal pituitary surgery in the United States
Chung, Thomas K.; Riley, Kristen O.
2015-01-01
Background: Intraoperative image guidance is a useful modality for transsphenoidal pituitary surgery. However, the outcomes associated with this technology have not been systematically evaluated. Objective: The purpose of the study was to quantify complication rates with and without the use of image guidance during transsphenoidal pituitary surgery using a nationwide database with broadly applicable results. Methods: A retrospective analysis of the Nationwide Inpatient Sample was performed from 2007 to 2011. Transsphenoidal pituitary resections for adenomas were identified by International Classification of Diseases-9th Revision, Clinical Modification code. The effect of image guidance on cerebrospinal fluid (CSF) leak complications and cost-benefit was analyzed. Results: A total of 48,848 transsphenoidal pituitary resections were identified, of which 77.5% were partial resections and 22.5% were complete. Pathologic indications included benign (89.3%), malignant primary (0.6%), and malignant secondary (0.4%). Complications included same-stay death (0.4%), CSF leak (8.8%), postoperative CSF rhinorrhea (1.9%), diabetes insipidus (12.4%), and meningitis (0.4%). Image guidance was employed in 7% (n = 3401) of all cases. When analyzed by modality, computed tomography (CT)-assisted procedures had lower CSF rhinorrhea rates (1.1%) compared with cases with no image guidance (1.9%), whereas magnetic resonance (MR)-assisted procedures had the highest rates (2.7%, χ2 p < 0.001). Rates of CSF leak demonstrated a similar pattern (CT 6.4%, no image guidance 8.9%, MR 9.2%, χ2 p < 0.001). CT-assisted surgery had significantly shorter length of stay (2.9 days) versus no image guidance (3.7 days, p < 0.001), lower total charges ($47,589 versus $62,629, p < 0.001), and lower total cost ($16,748 versus $20,530, p < 0.001). Conclusions: CT-assisted surgery is associated with a lower rate of CSF leak, shorter length of stay, and lower cost compared with patients without image guidance. Further studies that control for severity and extent of disease are warranted to confirm this finding. PMID:25975254
Graffeo, Christopher S; Dietrich, August R; Grobelny, Bartosz; Zhang, Meng; Goldberg, Judith D; Golfinos, John G; Lebowitz, Richard; Kleinberg, David; Placantonakis, Dimitris G
2014-08-01
Endoscopic endonasal surgery has been established as the safest approach to pituitary tumors, yet its role in other common skull base lesions has not been established. To answer this question, we carried out a systematic review of reported series of open and endoscopic endonasal approaches to four major skull base tumors: olfactory groove meningiomas (OGM), tuberculum sellae meningiomas (TSM), craniopharyngiomas (CRA), and clival chordomas (CHO). Data from 162 studies containing 5,701 patients were combined and compared for differences in perioperative mortality, gross total resection (GTR), cerebrospinal fluid (CSF) leak, neurological morbidity, post-operative visual function, post-operative anosmia, post-operative diabetes insipidus (DI), and post-operative obesity/hyperphagia. Weighted average rates for each outcome were calculated using relative study size. Our findings indicate similar rates of GTR and perioperative mortality between open and endoscopic approaches for all tumor types. CSF leak was increased after endoscopic surgery. Visual function symptoms were more likely to improve after endoscopic surgery for TSM, CRA, and CHO. Post-operative DI and obesity/hyperphagia were significantly increased after open resection in CRA. Recurrence rates per 1,000 patient-years of follow-up were higher in endoscopy for OGM, TSM, and CHO. Trends for open and endoscopic surgery suggested modest improvement in all outcomes over time. Our observations suggest that endonasal endoscopy is a safe alternative to craniotomy and may be preferred for certain tumor types. However, endoscopic surgery is associated with higher rates of CSF leak, and possibly increased recurrence rates. Prospective study with long-term follow-up is required to verify these preliminary observations.
Aburajab, Murad A; Max, Joshua B; Ona, Mel A; Gupta, Kapil; Burch, Miguel; Michael Feiz, F; Lo, Simon K; Jamil, Laith H
2017-11-01
Laparoscopic sleeve gastrectomy (LSG) is gaining popularity in treating morbid obesity. Prior studies showed a 3.5% risk of gastric sleeve stenosis (GSS). There is no consensus on how to treat these patients, and the role of endoscopic therapy has been addressed in only a few studies. We aim to assess the efficacy and safety of endoscopic stenting in the management of GSS following LSG. Retrospective data were reviewed from July 2009 to November 2013. Patients were referred for endoscopic therapy for symptoms or imaging findings suggestive of gastric leak or narrowing following LSG. Endoscopic therapy included the use of fully covered self-expanding esophageal metal stents (FCSEMS) in addition to over-the-scope clip system (OTSC) when necessary. All 27 patients were females with mean age of 40 years; six patients were excluded from the study. Major symptom was nausea and vomiting in 57% of the patients. Five of 21 patients had concomitant leaks. All 21 patients underwent FCSEMS placement, and four out of five patients (80%) with concomitant leak had OTSC. The success rate in both groups for resolution of stricture and leak was 100%, and no surgical intervention was required. There were no immediate or delayed complications of endoscopic therapy. Median follow-up of 6 months was available for 20/21 patients. Among patients with gastric leak, 80% had resolution of their symptoms compared with 93% of patients with GSS. Endoscopic therapy for LSG-related GSS or leaks with FCSEMS is highly effective and safe.
40 CFR 265.224 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... action plan. The response action plan must set forth the actions to be taken if the action leakage rate... paragraph (b) of this section. (b) If the flow rate into the leak detection system exceeds the action leakage rate for any sump, the owner or operator must: (1) Notify the Regional Administrator in writing of...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention Association Standard 631, “Spill Prevention, Minimum 10 Year Life Extension of Existing Steel Underground... pipe sections and fittings that have released product as a result of corrosion or other damage must be...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention Association Standard 631, “Spill Prevention, Minimum 10 Year Life Extension of Existing Steel Underground... pipe sections and fittings that have released product as a result of corrosion or other damage must be...
Sapphire Viewports for a Venus Probe
NASA Technical Reports Server (NTRS)
Bates, Stephen
2012-01-01
A document discusses the creation of a viewport suitable for use on the surface of Venus. These viewports are rated for 500 C and 100 atm pressure with appropriate safety factors and reliability required for incorporation into a Venus Lander. Sapphire windows should easily withstand the chemical, pressure, and temperatures of the Venus surface. Novel fixture designs and seals appropriate to the environment are incorporated, as are materials compatible with exploration vessels. A test cell was fabricated, tested, and leak rate measured. The window features polish specification of the sides and corners, soft metal padding of the sapphire, and a metal C-ring seal. The system safety factor is greater than 2, and standard mechanical design theory was used to size the window, flange, and attachment bolts using available material property data. Maintenance involves simple cleaning of the window aperture surfaces. The only weakness of the system is its moderate rather than low leak rate for vacuum applications.
Design and tritium permeation analysis of China HCCB TBM port cell
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiangfeng, S.; Guoqiang, H.; Zhiyong, H.
2015-03-15
China is planning to develop a helium-cooled ceramic breeder (HCCB) test blanket module (TBM) on ITER to test key blanket technologies. In this paper, the design and tritium permeation analysis of China HCCB TBM port cell are introduced. A theoretical model has been developed to estimate tritium permeation rates and leak rates from the components and pipes which China has scheduled to house in the port cell. It is shown that on normal working conditions, the permeation and leak rate of the systems in the port cell will be no higher than 1.58 Ci/d without the use of tritium permeationmore » barriers, and 0.10 Ci/d with the use of tritium permeation barriers. It also appears that tritium permeation barriers are necessary for high temperature components such as the reduction bed and the heater.« less
4D ERT Monitoring of Subsurface Water Pipe Leakage During a Controlled Field Experiment
NASA Astrophysics Data System (ADS)
Inauen, C.; Chambers, J. E.; Wilkinson, P. B.; Meldrum, P.; Swift, R. T.; Uhlemann, S.; Gunn, D.; Dashwood, B.; Taxil, J.; Curioni, G.
2016-12-01
Locating and delineating leakage from subsurface pipelines is an important task for civil engineers. 4D Electrical Resistivity Tomography (ERT) allows changes in subsurface resistivity to be imaged at a high spatial and temporal resolution in a minimally invasive manner. It is therefore a promising tool to supplement conventional point-sensing techniques to monitor subsurface flow processes. To assess the efficacy of ERT for pipe leakage monitoring several controlled leak experiments were carried out at a test site in Blagdon, Bristol, UK. To simulate the leak, a plastic pipe with a hole was buried below a flat, grassed area at a depth of 0.7 m, representing a standard UK mains water pipe installation. The water table at the site lies well below the surface meaning that the experiment took entirely place in the vadose zone, where changes in resistivity are primarily sensitive to water content variations. The ERT array covered an area of 6.5m x 6.5m around the leak location. Data acquisition was carried out with the BGS PRIME (Proactive Infrastructure Monitoring and Evaluation) system, which facilitates remote scheduling and autonomous ERT data collection and transmission. To obtain the resistivity changes of the subsurface a 4D inversion was carried out using a Gauss-Newton approach with spatial and temporal smoothness constraints. We were able to reliably observe the onset, spread and cessation of the leakage. Measurements from in-situ soil sensors at several depths above and below the leak complemented the ERT data and allowed us to assess their reliability and directly relate them to hydrogeological processes. Moreover, through experimental tests with soil samples from the test area, a Waxman-Smits relation was obtained to directly convert the changes in electrical resistivity to gravimetric soil moisture content. With future experiments on the test site more work is planned towards survey optimization, automated processing and tracking of leakage plumes.
Chelliah, Pandian; Murgesan, Kasinathan; Samvel, Sosamma; Chelamchala, Babu Rao; Tammana, Jayakumar; Nagarajan, Murali; Raj, Baldev
2010-07-10
Optical-fiber-based sensors have inherent advantages, such as immunity to electromagnetic interference, compared to the conventional sensors. Distributed optical fiber sensor (DOFS) systems, such as Raman and Brillouin distributed temperature sensors are used for leak detection. The inherent noise of fiber-based systems leads to occasional false alarms. In this paper, a methodology is proposed to overcome this. This uses a looped back fiber mode in DOFS and voting logic is employed to considerably reduce the false alarm rate.
10 CFR 55.59 - Requalification.
Code of Federal Regulations, 2012 CFR
2012-01-01
... system. (U) Fuel cladding failure or high activity in reactor coolant or offgas. (V) Turbine or generator... heatup rate is established. (B) Plant shutdown. (C) Manual control of steam generators or feedwater or... generator leaks (2)Inside and outside primary containment (3)Large and small, including lead-rate...
10 CFR 55.59 - Requalification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... system. (U) Fuel cladding failure or high activity in reactor coolant or offgas. (V) Turbine or generator... heatup rate is established. (B) Plant shutdown. (C) Manual control of steam generators or feedwater or... generator leaks (2)Inside and outside primary containment (3)Large and small, including lead-rate...
10 CFR 55.59 - Requalification.
Code of Federal Regulations, 2013 CFR
2013-01-01
... system. (U) Fuel cladding failure or high activity in reactor coolant or offgas. (V) Turbine or generator... heatup rate is established. (B) Plant shutdown. (C) Manual control of steam generators or feedwater or... generator leaks (2)Inside and outside primary containment (3)Large and small, including lead-rate...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Kyoung Mo; Jee, Kye Kwang; Pyo, Chang Ryul
The basis of the leak before break (LBB) concept is to demonstrate that piping will leak significantly before a double ended guillotine break (DEGB) occurs. This is demonstrated by quantifying and evaluating the leak process and prescribing safe shutdown of the plant on the basis of the monitored leak rate. The application of LBB for power plant design has reduced plant cost while improving plant integrity. Several evaluations employing LBB analysis on system piping based on DEGB design have been completed. However, the application of LBB on main steam (MS) piping, which is LBB applicable piping, has not been performedmore » due to several uncertainties associated with occurrence of steam hammer and dynamic strain aging (DSA). The objective of this paper is to demonstrate the applicability of the LBB design concept to main steam lines manufactured with SA106 Gr.C carbon steel. Based on the material properties, including fracture toughness and tensile properties obtained from the comprehensive material tests for base and weld metals, a parametric study was performed as described in this paper. The PICEP code was used to determine leak size crack (LSC) and the FLET code was used to perform the stability assessment of MS piping. The effects of material properties obtained from tests were evaluated to determine the LBB applicability for the MS piping. It can be shown from this parametric study that the MS piping has a high possibility of design using LBB analysis.« less
Zhang, Xueyan; Ma, Xin; Wu, Yang; Li, Yue
2015-06-15
The effects of leaked CO2 on plant and soil constitute a key objective of carbon capture and storage (CCS) safety. The effects of leaked CO2 on trace soil gas (e.g., methane (CH4) and nitrous oxide (N2O) emissions in farmlands are not well-understood. This study simulated the effects of elevated soil CO2 on CH4 and N2O through pot experiments. The results revealed that significant increases of CH4 and N2O emissions were induced by the simulated CO2 leakages; the emission rates of CH4 and N2O were substantial, reaching about 222 and 48 times than that of the control, respectively. The absolute global warming potentials (GWPs) of the additional CH4 and N2O are considerable, but the cumulative GWPs of the additional CH4 and N2O only accounted for 0.03% and 0.06%, respectively, of the cumulative amount of leaked CO2 under high leakage conditions. The results demonstrate that leakage from CCS projects may lead to additional greenhouse gas emissions from soil; however, in general, the amount of additional CH4 and N2O emissions is negligible when compared with the amount of leaked CO2. Copyright © 2015 Elsevier B.V. All rights reserved.
Large-area imager of hydrogen leaks in fuel cells using laser-induced breakdown spectroscopy.
Hori, M; Hayano, R S; Fukuta, M; Koyama, T; Nobusue, H; Tanaka, J
2009-10-01
We constructed a simple device, which utilized laser-induced breakdown spectroscopy to image H2 gas leaking from the surfaces of hydrogen fuel cells to ambient air. Nanosecond laser pulses of wavelength lambda=532 nm emitted from a neodymium-doped yttrium aluminum garnet laser were first compressed to a pulse length Deltat<1 ns using a stimulated Brillouin backscattering cell. Relay-imaging optics then focused this beam onto the H(2) leak and initiated the breakdown plasma. The Balmer-alpha (H-alpha) emission that emerged from this was collected with a 2-m-long macrolens assembly with a 90-mm-diameter image area, which covered a solid angle of approximately 1 x 10(-3)pi steradians seen from the plasma. The H-alpha light was isolated by two 100-mm-diameter interference filters with a 2 nm bandpass, and imaged by a thermoelectrically cooled charge-coupled device camera. By scanning the position of the laser focus, the spatial distribution of H2 gas over a 90-mm-diameter area was photographed with a spatial resolution of < or = 5 mm. Photoionization of the water vapor in the air caused a strong H-alpha background. By using pure N2 as a buffer gas, H2 leaks with rates of <1 cc/min were imaged. We also studied the possibilities of detecting He, Ne, or Xe gas leaks.
Effect of varying the pressurisation rate during noninvasive pressure support ventilation.
Prinianakis, G; Delmastro, M; Carlucci, A; Ceriana, P; Nava, S
2004-02-01
The aim of the study was to assess the effects of varying the pressurisation rate during noninvasive pressure support ventilation on patients' breathing pattern, inspiratory effort, arterial blood gases, tolerance to ventilation and amount of air leakage. A total of 15 chronic obstructive pulmonary disease patients recovering from an acute episode of hypercapnic acute respiratory failure were studied during four randomised trials with different levels of pressurisation rate. No significant changes were observed in breathing pattern and arterial blood gases between the different runs. The pressure time product of the diaphragm, an estimate of its metabolic consumption, was significantly lower with all pressurisation rates than with spontaneous breathing, but was significantly lowest with the fastest rate. However, air leak, assessed by the ratio between expired and inspired tidal volumes, increased and the patients' tolerance of ventilation, measured using a standardised scale, was significantly poorer with the fastest pressurisation rate. In chronic obstructive pulmonary disease patients recovering from an episode of acute hypercapnic respiratory failure and ventilated with noninvasive pressure support ventilation, different pressurisation rates resulted in different reductions in the pressure time product of the diaphragm; this reduction was greater with the fastest rate, but was accompanied by significant air leaks and poor tolerance.
Rubber contact mechanics: adhesion, friction and leakage of seals.
Tiwari, A; Dorogin, L; Tahir, M; Stöckelhuber, K W; Heinrich, G; Espallargas, N; Persson, B N J
2017-12-13
We study the adhesion, friction and leak rate of seals for four different elastomers: Acrylonitrile Butadiene Rubber (NBR), Ethylene Propylene Diene (EPDM), Polyepichlorohydrin (GECO) and Polydimethylsiloxane (PDMS). Adhesion between smooth clean glass balls and all the elastomers is studied both in the dry state and in water. In water, adhesion is observed for the NBR and PDMS elastomers, but not for the EPDM and GECO elastomers, which we attribute to the differences in surface energy and dewetting. The leakage of water is studied with rubber square-ring seals squeezed against sandblasted glass surfaces. Here we observe a strongly non-linear dependence of the leak rate on the water pressure ΔP for the elastomers exhibiting adhesion in water, while the leak rate depends nearly linearly on ΔP for the other elastomers. We attribute the non-linearity to some adhesion-related phenomena, such as dewetting or the (time-dependent) formation of gas bubbles, which blocks fluid flow channels. Finally, rubber friction is studied at low sliding speeds using smooth glass and sandblasted glass as substrates, both in the dry state and in water. The measured friction coefficients are compared to theory, and the origin of the frictional shear stress acting in the area of real contact is discussed. The NBR rubber, which exhibits the strongest adhesion both in the dry state and in water, also shows the highest friction both in the dry state and in water.
NASA Technical Reports Server (NTRS)
Deveikis, W. D.; Bartlett, W.
1978-01-01
An experimental aerodynamic heating investigation was conducted to determine effects of hot boundary-layer ingestion into the cove on the windward surface between a wing and elevon for cove seal leak areas nominally between 0 and 100 percent of cove entrance area. Pressure and heating-rate distributions were obtained on the wing and elevon surfaces and on the cove walls of a full-scale model that represented a section of the cove region on the space shuttle orbiter. Data were obtained for both attached and separated turbulent boundary layers upstream of the unswept cove entrance. Average free-stream Mach number was 6.9, average free-stream unit Reynolds numbers were 1.31 x 10 to the 6th power and 4.40 x 10 to the 6th power per meter (0.40 x 10 to the 6th power and 1.34 x 10 to the 6th power per foot), and average total temperature was 1888 K (3400 R). Cove pressures and heating rates varied as a function of seal leak area independent of leak aspect ratio. Although cove heating rates for attached flow did not appear intolerable, it was postulated that convective heating in the cove may increase with time. For separated flow, the cove environment was considered too severe for unprotected interior structures of control surfaces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Lanning; J. Arps
2004-04-01
Extending upon development efforts last quarter to produce ''free-standing'', copper and palladium alloy films, the goal this quarter has been to produce pinhole-free, Pd-Cu alloy films up to 5 x 5 inches in area (1-3 microns thick) using both magnetron sputtering and e-beam evaporation on PVA (Solublon) and polystyrene backing materials. A set of experiments were conducted to assess processing methods/solutions chemistry for removing the polymer backing material from the Pd-Cu film. For all of the alloy films produced to this point, we were unable to produce pinhole-free films on plastic although we were able to produce free-standing Pd-Cu filmsmore » at less than 0.5 microns thick with minimal intrinsic stress. Subsequently, to evaluate gas permeation and leakage across the films, two films were sandwiched together on top of a porous Monel support disc (25 mm in diameter) and then tested in a leak test apparatus. Using two Cu films (10 micron thickness total) in the sandwich configuration, leak rates were about 20% of the background leak rate.« less
Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M
2015-07-01
If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants <33 weeks gestational age in the delivery room. Infants born at the Royal Alexandra Hospital from April to September 2013 at <33 weeks gestational age who received mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, A.G.; Espie, G.S.; Canvin, D.T.
1989-07-01
Carbon oxysulfide (carbonyl sulfide, COS) is a close structural analog of CO{sub 2}. Although hydrolysis of COS (to CO{sub 2} and H{sub 2}S) does occur at alkaline pH (> 9), at pH 8.0 the rate of hydrolysis is slow enough to allow investigation of COS as a possible substrate and inhibitor of the active CO{sub 2} transport system of Synechococcus UTEX 625. A light-dependent uptake of COS was observed that was inhibited by CO{sub 2} and the ATPase inhibitor diethylstilbestrol. The COS taken up by the cells could not be recovered when the lights were turned off or when acidmore » was added. Bovine erythrocyte carbonic anhydrase catalyzed the stoichiometric hydrolysis of COS to H{sub 2}S. The active transport of CO{sub 2} was inhibited by COS in an apparently competitive manner. When Na{sup +}-dependent HCO{sub 3}{sup {minus}} transport was allowed in the presence of COS, the extracellular (CO{sub 2}) rose considerably above the equilibrium level. This CO{sub 2} appearing in the medium was derived from the dehydration of transported HCO{sub 3}{sup {minus}} and was leaked from the cells. In the presence of COS the return to the cells of this leaked CO{sub 2} was inhibited. These results showed that the Na{sup +}-dependent HCO{sub 3}{sup {minus}} transport was not inhibited by COS, whereas active CO{sub 2} transport was inhibited. The steady state rate of CO{sub 2} fixation was, however, inhibited about 50% in the presence of COS. This inhibition can be at least partially explained by the significant leakage of CO{sub 2} from the cells that occurred when CO{sub 2} uptake was inhibited by COS. Neither CS{sub 2} nor N{sub 2}O acted like COS. It is concluded that COS is an effective and selective inhibitor of active CO{sub 2} transport.« less
Shimasaki, Noriko; Shinohara, Katsuaki; Morikawa, Hideki
2017-12-07
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task.
SHIMASAKI, Noriko; SHINOHARA, Katsuaki; MORIKAWA, Hideki
2017-01-01
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task. PMID:28978815
Sotomayor-González, Arturo; Díaz-Martínez, Armando José; Radillo-Gil, Ramón; García-Estrada, Everardo; Morales-Gómez, Jesús Alberto; Palacios-Ortiz, Isaac Jair; Pérez-Cárdenas, Samuel; Arteaga-Treviño, Mauricio; De León, Ángel Martínez-Ponce
2016-01-01
Objective Report a modification of the “rescue flap” technique using a direct endonasal approach with a partial superior septectomy for approaching pituitary tumors developed in our institution. Design Prospective study. Setting Hospital Universitario “Dr. José Eleuterio González,” Universidad Autónoma de Nuevo León. Main Outcome Measures Since April 2015, we have performed 19 cases employing a direct endonasal approach with partial superior septectomy. Results and a technical note are described below. Results Nineteen patients were included in this report. Six patients presented transoperatory cerebrospinal fluid (CSF) leak, so a nasoseptal rescue flap was harvested. No patients developed postoperative CSF leak in this group. Two patients were submitted to a second surgical procedure. Nasoseptal flap was harvested without complications. In both patients, the size of the flap was enough to cover the dural defect and avoid CSF leak. Conclusion Direct endonasal approach with a partial posterior septectomy allows enough exposition of the sphenoidal sinus while preserving the nasoseptal septum with the possibility of a successful rescue flap when needed. PMID:28321383
Sotomayor-González, Arturo; Díaz-Martínez, Armando José; Radillo-Gil, Ramón; García-Estrada, Everardo; Morales-Gómez, Jesús Alberto; Palacios-Ortiz, Isaac Jair; Pérez-Cárdenas, Samuel; Arteaga-Treviño, Mauricio; De León, Ángel Martínez-Ponce
2017-04-01
Objective Report a modification of the "rescue flap" technique using a direct endonasal approach with a partial superior septectomy for approaching pituitary tumors developed in our institution. Design Prospective study. Setting Hospital Universitario "Dr. José Eleuterio González," Universidad Autónoma de Nuevo León. Main Outcome Measures Since April 2015, we have performed 19 cases employing a direct endonasal approach with partial superior septectomy. Results and a technical note are described below. Results Nineteen patients were included in this report. Six patients presented transoperatory cerebrospinal fluid (CSF) leak, so a nasoseptal rescue flap was harvested. No patients developed postoperative CSF leak in this group. Two patients were submitted to a second surgical procedure. Nasoseptal flap was harvested without complications. In both patients, the size of the flap was enough to cover the dural defect and avoid CSF leak. Conclusion Direct endonasal approach with a partial posterior septectomy allows enough exposition of the sphenoidal sinus while preserving the nasoseptal septum with the possibility of a successful rescue flap when needed.