Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS
Adamic, M. L.; Lister, T. E.; Dufek, E. J.; ...
2015-03-25
This paper presents an evaluation of an alternate method for preparing environmental samples for 129I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Furthermore, precipitated silver iodide samples are usually mixed with niobium or silver powdermore » prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.« less
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROHIBITIONS Self-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a... of use in this chemical extraction and chemical analysis comparison study, a person may adjust PCB...
Kurosaki, Hiromu; Mueller, Rebecca J.; Lambert, Susan B.; ...
2016-07-15
An alternate method of preparing actinide alpha counting sources was developed in place of electrodeposition or lanthanide fluoride micro-precipitation. The method uses lanthanide hydroxide micro-precipitation to avoid the use of hazardous hydrofluoric acid. Lastly, it provides a quicker, simpler, and safer way of preparing actinide alpha counting sources in routine, production-type laboratories that process many samples daily.
Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen
2015-01-01
A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.
Final Report for X-ray Diffraction Sample Preparation Method Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ely, T. M.; Meznarich, H. K.; Valero, T.
WRPS-1500790, “X-ray Diffraction Saltcake Sample Preparation Method Development Plan/Procedure,” was originally prepared with the intent of improving the specimen preparation methodology used to generate saltcake specimens suitable for XRD-based solid phase characterization. At the time that this test plan document was originally developed, packed powder in cavity supports with collodion binder was the established XRD specimen preparation method. An alternate specimen preparation method less vulnerable, if not completely invulnerable to preferred orientation effects, was desired as a replacement for the method.
Characterization of the tank 51 alternate reductant sludge batch 9 slurry sample (HTF-51-15-130)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reboul, S. H.
Tank 51 slurry sample HTF-51-15-130 was collected following sludge washing at the Tank Farm. The sample was received at SRNL and then characterized in preparation for qualification of the alternate reductant Sludge Batch 9 (SB9) flowsheet. In this characterization, densities, solids distribution, elemental constituents, anionic constituents, carbon content, and select radioisotopes were quantified.
Robinson, T; Bronson, B; Gogolek, P; Mehrani, P
2016-02-01
Thermo-gravimetric analysis (TGA) is a useful method for characterizing fuels. In the past it has been applied to the study of refuse derived fuel (RDF) and related materials. However, the heterogeneity of RDF makes the preparation of small representative samples very difficult and this difficulty has limited the effectiveness of TGA for characterization of RDF. A TGA method was applied to a variety of materials prepared from a commercially available RDF using a variety of procedures. Applicability of TGA method to the determination of the renewable content of RDF was considered. Cryogenic ball milling was found to be an effective means of preparing RDF samples for TGA. When combined with an effective sample preparation, TGA could be used as an alternative method for assessing the renewable content of RDF. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Periat, Aurélie; Kohler, Isabelle; Thomas, Aurélien; Nicoli, Raul; Boccard, Julien; Veuthey, Jean-Luc; Schappler, Julie; Guillarme, Davy
2016-03-25
Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode. Copyright © 2015 Elsevier B.V. All rights reserved.
Imaging MALDI MS of Dosed Brain Tissues Utilizing an Alternative Analyte Pre-extraction Approach
NASA Astrophysics Data System (ADS)
Quiason, Cristine M.; Shahidi-Latham, Sheerin K.
2015-06-01
Matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry has been adopted in the pharmaceutical industry as a useful tool to detect xenobiotic distribution within tissues. A unique sample preparation approach for MALDI imaging has been described here for the extraction and detection of cobimetinib and clozapine, which were previously undetectable in mouse and rat brain using a single matrix application step. Employing a combination of a buffer wash and a cyclohexane pre-extraction step prior to standard matrix application, the xenobiotics were successfully extracted and detected with an 8 to 20-fold gain in sensitivity. This alternative approach for sample preparation could serve as an advantageous option when encountering difficult to detect analytes.
Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing
2014-06-15
VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.
Patil, Nitin S; Mendhe, Rakesh B; Sankar, Ajeet A; Iyer, Harish
2008-01-11
In preparative chromatography, often the solubility of the sample in the mobile phase is limited, making the mobile phase unsuitable as a solvent for preparation of load. Generally, solvents that have high solubility for the sample also have higher elution strengths than the mobile phase. Additionally, at high loading volumes, these strong sample solvents are known to adversely affect the band profiles leading to poor chromatographic performance. Here, we show that controlling the mobile phase strength during loading and post-load elution resulted in improved band profiles when the sample solvent was stronger than the mobile phase. Such an approach improves performance in preparative chromatography by allowing either higher sample loading or higher organic content in mobile phase (without loss of yield). Alternately, the approach can be used for improvement in performance by increase in yield or product purity.
Polysilicon Prepared from SiCl4 by Atmospheric-Pressure Non-Thermal Plasma
NASA Astrophysics Data System (ADS)
Li, Xiaosong; Wang, Nan; Yang, Jinhua; Wang, Younian; Zhu, Aimin
2011-10-01
Non-thermal plasma at atmospheric pressure was explored for the preparation of polysilicon from SiCl4. The power supply sources of positive pulse and alternating current (8 kHz and 100 kHz) were compared for polysilicon preparation. The samples prepared by using the 100 kHz power source were crystalline silicon. The effects of H2 and SiCl4 volume fractions were investigated. The optical emission spectra showed that silicon species played an important role in polysilicon deposition
ERIC Educational Resources Information Center
de Berg, Kevin; Chapman, Ken
1996-01-01
Describes an alternative technique for determining the molar volume of hydrogen from the metal-acid reaction in which the metal sample is encased in a specially prepared cage and a pipette filler is used to fill an inverted burette with water. Eliminates some difficulties encountered with the conventional technique. (JRH)
Space law information system design, phase 2
NASA Technical Reports Server (NTRS)
Morenoff, J.; Roth, D. L.; Singleton, J. W.
1973-01-01
Design alternatives were defined for the implementation of a Space Law Information System for the Office of the General Counsel, NASA. A thesaurus of space law terms was developed and a selected document sample indexed on the basis of that thesaurus. Abstracts were also prepared for the sample document set.
Sample preparation and EFTEM of Meat Samples for Nanoparticle Analysis in Food
NASA Astrophysics Data System (ADS)
Lari, L.; Dudkiewicz, A.
2014-06-01
Nanoparticles are used in industry for personal care products and the preparation of food. In the latter application, their functions include the prevention of microbes' growth, increase of the foods nutritional value and sensory quality. EU regulations require a risk assessment of the nanoparticles used in foods and food contact materials before the products can reach the market. However, availability of validated analytical methodologies for detection and characterisation of the nanoparticles in food hampers appropriate risk assessment. As part of a research on the evaluation of the methods for screening and quantification of Ag nanoparticles in meat we have tested a new TEM sample preparation alternative to resin embedding and cryo-sectioning. Energy filtered TEM analysis was applied to evaluate thickness and the uniformity of thin meat layers acquired at increasing input of the sample demonstrating that the protocols used ensured good stability under the electron beam, reliable sample concentration and reproducibility.
Preparation and validation of gross alpha/beta samples used in EML`s quality assessment program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scarpitta, S.C.
1997-10-01
A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory`s (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ({sup 241}Am, {sup 230}Th and {sup 238}Pu) andmore » beta ({sup 90}Sr/{sup 90}Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared.« less
Automated cellular sample preparation using a Centrifuge-on-a-Chip.
Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino
2011-09-07
The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.
Investigating a Drop-on-Demand Microdispenser for Standardized Sample Preparation
2011-09-01
including the printing of photodiodes , polymer and protein arrays , and in electronics manufacturing (4–7). These applications benefit from the wide...photograph of an array of microdroplets demonstrates a more even sample dispersion when sample is dispensed with a DOD microdispenser... threats encountered. A variety of techniques that offer temporary alternatives have been employed, including drop-and-dry (dropcasting) and spray
Innovative procedure for the determination of gross-alpha/gross-beta activities in drinking water.
Wisser, S; Frenzel, E; Dittmer, M
2006-03-01
An alternative sample preparation method for the determination of gross-alpha/beta activity concentrations in drinking water is introduced in this paper. After the freeze-drying of tap water samples, determination by liquid scintillation counting can be applied utilizing alpha/beta separation. It has been shown that there is no adsorption or loss of solid radionuclides during the freeze-drying procedure. However, the samples have to be measured quickly after the preparation since the ingrowth of daughter isotopes negatively effects the measurement. The limits of detection for gross-alpha and gross-beta activity are in the range 25-210 mBq/l, respectively, for a measurement time of only 8-9 h.
Welna, Maja; Szymczycha-Madeja, Anna
2014-04-01
Various sample preparation procedures, such as common wet digestions and alternatives based on solubilisation in aqua regia or tetramethyl ammonium hydroxide, were compared for the determination of the total Ba, Ca, Cr, Cd, Cu, Fe, Mg, Mn, Ni, P, Pb, Se, Sr and Zn contents in Brazil nuts using inductively coupled plasma optical emission spectrometry (ICP-OES). For measurement of Se, a hydride generation technique was used. The performance of these procedures was measured in terms of precision, accuracy and limits of detection of the elements. It was found that solubilisation in aqua regia gave the best results, i.e. limits of detection from 0.60 to 41.9 ng ml(-1), precision of 1.0-3.9% and accuracy better than 5%. External calibration with simple standard solutions could be applied for the analysis. The proposed procedure is simple, reduces sample handling, and minimises the time and reagent consumption. Thus, this can be a vital alternative to traditional sample treatment approaches based on the total digestion with concentrated reagents. A phenomenon resulting from levels of Ba, Se and Sr in Brazil nuts was also discussed.
Solid-Phase Extraction (SPE): Principles and Applications in Food Samples.
Ötles, Semih; Kartal, Canan
2016-01-01
Solid-Phase Extraction (SPE) is a sample preparation method that is practised on numerous application fields due to its many advantages compared to other traditional methods. SPE was invented as an alternative to liquid/liquid extraction and eliminated multiple disadvantages, such as usage of large amount of solvent, extended operation time/procedure steps, potential sources of error, and high cost. Moreover, SPE can be plied to the samples combined with other analytical methods and sample preparation techniques optionally. SPE technique is a useful tool for many purposes through its versatility. Isolation, concentration, purification and clean-up are the main approaches in the practices of this method. Food structures represent a complicated matrix and can be formed into different physical stages, such as solid, viscous or liquid. Therefore, sample preparation step particularly has an important role for the determination of specific compounds in foods. SPE offers many opportunities not only for analysis of a large diversity of food samples but also for optimization and advances. This review aims to provide a comprehensive overview on basic principles of SPE and its applications for many analytes in food matrix.
Ambient Mass Spectrometry in Cancer Research.
Takats, Z; Strittmatter, N; McKenzie, J S
2017-01-01
Ambient ionization mass spectrometry was developed as a sample preparation-free alternative to traditional MS-based workflows. Desorption electrospray ionization (DESI)-MS methods were demonstrated to allow the direct analysis of a broad range of samples including unaltered biological tissue specimens. In contrast to this advantageous feature, nowadays DESI-MS is almost exclusively used for sample preparation intensive mass spectrometric imaging (MSI) in the area of cancer research. As an alternative to MALDI, DESI-MSI offers matrix deposition-free experiment with improved signal in the lower (<500m/z) range. DESI-MSI enables the spatial mapping of tumor metabolism and has been broadly demonstrated to offer an alternative to frozen section histology for intraoperative tissue identification and surgical margin assessment. Rapid evaporative ionization mass spectrometry (REIMS) was developed exclusively for the latter purpose by the direct combination of electrosurgical devices and mass spectrometry. In case of the REIMS technology, aerosol particles produced by electrosurgical dissection are subjected to MS analysis, providing spectral information on the structural lipid composition of tissues. REIMS technology was demonstrated to give real-time information on the histological nature of tissues being dissected, deeming it an ideal tool for intraoperative tissue identification including surgical margin control. More recently, the method has also been used for the rapid lipidomic phenotyping of cancer cell lines as it was demonstrated in case of the NCI-60 cell line collection. © 2017 Elsevier Inc. All rights reserved.
dos S Luz, Diandra; de S Ourique, Fernanda; Scarparo, Roberta K; Vier-Pelisser, Fabiana V; Morgental, Renata D; Waltrick, Silvana B G; de Figueiredo, José A P
2015-01-01
The aim of this preliminary study was to evaluate the desirability of alternative models of artificial teeth versus extracted natural teeth for use in preclinical dental education. Specifically, the study was designed to compare the preparation time and perceptions of difficulty of undergraduate dental students and endodontists in carrying out root canal preparations on resin models (both clear and opaque) and extracted natural teeth. Twenty participants-ten fifth-year students at a Brazilian dental school and ten endodontists with at least five years' experience in the specialty-performed root canal instrumentation on two samples of each model. Preparation times were recorded, and the participants completed a questionnaire about the anatomical and physical characteristics of these models. The results showed that the time required for performing endodontic procedures in the natural teeth was higher than in the alternative models. The perceptions of the students and specialists regarding some topics on the questionnaire were significantly different. The students had more positive opinions about artificial teeth made of opaque resin, while the specialists had more positive opinions about simulated root canals in clear resin blocks. This study suggests that neither of the alternative models fulfilled requirements to replace natural teeth in endodontic teaching; improvements are still necessary to accomplish this goal.
Bonadio, Federica; Margot, Pierre; Delémont, Olivier; Esseiva, Pierre
2008-11-20
Headspace solid-phase microextraction (HS-SPME) is assessed as an alternative to liquid-liquid extraction (LLE) currently used for 3,4-methylenedioxymethampethamine (MDMA) profiling. Both methods were compared evaluating their performance in discriminating and classifying samples. For this purpose 62 different seizures were analysed using both extraction techniques followed by gas chromatography-mass spectroscopy (GC-MS). A previously validated method provided data for HS-SPME, whereas LLE data were collected applying a harmonized methodology developed and used in the European project CHAMP. After suitable pre-treatment, similarities between sample pairs were studied using the Pearson correlation. Both methods enable to distinguish between samples coming from the same pre-tabletting batches and samples coming from different pre-tabletting batches. This finding emphasizes the use of HS-SPME as an effective alternative to LLE, with additional advantages such as sample preparation and a solvent-free process.
Mavridou, A; Smeti, E; Mandilara, G; Mandilara, G; Boufa, P; Vagiona-Arvanitidou, M; Vantarakis, A; Vassilandonopoulou, G; Pappa, O; Roussia, V; Tzouanopoulos, A; Livadara, M; Aisopou, I; Maraka, V; Nikolaou, E; Mandilara, G
2010-01-01
In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.
The effect of replaced recycled glass on thermal conductivity and compression properties of cement
NASA Astrophysics Data System (ADS)
khalil, A. S.; Mahmoud, M. A.; AL-Hathal, A.; Jawad, M. K.; Mozahim, B. M.
2018-05-01
This study deal with recycling of waste colorless glass bottles which are prepared as a powder and use them as an alternative for cement to save the environment from west and reduce some of cement(ceramic) damage and interactions with conserving physical properties of block concrete. Different weight percentage (0%, 2%, 4%, 5%, 6%, 8%, 10%, 15%, 20% and 25%) of recycled glass bottle were use in this research to be replaced by a certain percentages of cement. Thermal conductivity was studied for prepared samples. Results show that the thermal conductivity decrease with the increase of weight percentage of glass powder comparing with the stander sample.
Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites
Lucchi, Naomi W.; Gaye, Marie; Diallo, Mammadou Alpha; Goldman, Ira F.; Ljolje, Dragan; Deme, Awa Bineta; Badiane, Aida; Ndiaye, Yaye Die; Barnwell, John W.; Udhayakumar, Venkatachalam; Ndiaye, Daouda
2016-01-01
Isothermal nucleic acid amplification assays such as the loop mediated isothermal amplification (LAMP), are well suited for field use as they do not require thermal cyclers to amplify the DNA. To further facilitate the use of LAMP assays in remote settings, simpler sample preparation methods and lyophilized reagents are required. The performance of a commercial malaria LAMP assay (Illumigene Malaria LAMP) was evaluated using two sample preparation workflows (simple filtration prep (SFP)) and gravity-driven filtration prep (GFP)) and pre-dispensed lyophilized reagents. Laboratory and clinical samples were tested in a field laboratory in Senegal and the results independently confirmed in a reference laboratory in the U.S.A. The Illumigene Malaria LAMP assay was easily implemented in the clinical laboratory and gave similar results to a real-time PCR reference test with limits of detection of ≤2.0 parasites/μl depending on the sample preparation method used. This assay reliably detected Plasmodium sp. parasites in a simple low-tech format, providing a much needed alternative to the more complex molecular tests for malaria diagnosis. PMID:27827432
Extraction and derivatization of polar herbicides for GC-MS analyses.
Ranz, Andreas; Maier, Eveline; Motter, Herbert; Lankmayr, Ernst
2008-09-01
A sample preparation procedure including a simultaneous microwave-assisted (MA) extraction and derivatization for the determination of chlorophenoxy acids in soil samples is presented. For a selective and sensitive measurement, an analytical technique such as GC coupled with MS needs to be adopted. For GC analyses, chlorophenoxy acids have to be converted into more volatile and thermally stable derivatives. Derivatization by means of microwave radiation offers new alternatives in terms of shorter derivatization time and reduces susceptibility for the formation of artefacts. Extraction and derivatization into methyl esters (ME) were performed with sulphuric acid and methanol. Due to the novelty of the simultaneous extraction and derivatization assisted by means of microwave radiation, a careful investigation and optimization of influential reaction parameters was necessary. It could be shown that the combination of sulphuric acid and methanol provides a fast sample preparation including an efficient clean up procedure. The data obtained by the described method are in good agreement with those published for the reference material. Finally, compared to conventional heating and also to the standard procedure of the EPA, the sample preparation time could be considerably shortened.
Feng, Xing-Yao; Liu, Hong-Xia; Wang, Xing; Zhao, Lu; Fei, Chen-Xi; Liu, He-Lei
2016-12-01
The mechanism of flat band voltage (VFB) shift for alternate La2O3/Al2O3 multilayer stack structures in different annealing condition is investigated. The samples were prepared for alternate multilayer structures, which were annealed in different conditions. The capacitance-voltage (C-V) measuring results indicate that the VFB of samples shift negatively for thinner bottom Al2O3 layer, increasing annealing temperature or longer annealing duration. Simultaneously, the diffusion of high-k material to interfaces in different multilayer structures and annealing conditions is observed by X-ray photoelectron spectroscopy (XPS). Based on the dipole theory, a correlation between the diffusion effect of La towards bottom Al2O3/Si interface and VFB shift is found. Without changing the dielectric constant k of films, VFB shift can be manipulated by controlling the single-layer cycles and annealing conditions of alternate high-k multilayer stack.
National Surface Water Survey, western wilderness area lakes: environmental assessment. Draft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-03-01
The US Environmental Protection Agency (EPA) is proposing to sample 498 lakes in federally designated wilderness areas and national parks during the western part of the National Surface Water Survey (NSW). The NSWS has been undertaken to provide high quality data for evaluating the nature and extent of acid deposition throughout the United States. Sampling protocols established for the national survey call for the use of helicopters to gain access to lakes for sampling. Helicopters have already been used in the eastern and midwestern parts of the survey. The US Forest Service (FS) and the National Park Service (NPS) willmore » have to decide which sampling plan for wilderness areas, if any, can be approved under the Wilderness Act of 1964. This Environmental Assessment (EA) has been prepared to evaluate the environmental consequences of alternative means of gaining access to wilderness areas to meet the objectives of the NSWS. Based on this evaluation, EPA has reviewed the possible sampling alternatives and reached a conclusion on the preferred alternative. This assessment is being provided to the FS and the NPS for their use in evaluating the alternatives, including EPA's preferred one. As a result of its evaluation, EPA believes that wilderness area lakes should be included in the survey and that the preferred means of access is using helicopters. 94 references, 14 figures, 18 tables.« less
Preparation of highly multiplexed small RNA sequencing libraries.
Persson, Helena; Søkilde, Rolf; Pirona, Anna Chiara; Rovira, Carlos
2017-08-01
MicroRNAs (miRNAs) are ~22-nucleotide-long small non-coding RNAs that regulate the expression of protein-coding genes by base pairing to partially complementary target sites, preferentially located in the 3´ untranslated region (UTR) of target mRNAs. The expression and function of miRNAs have been extensively studied in human disease, as well as the possibility of using these molecules as biomarkers for prognostication and treatment guidance. To identify and validate miRNAs as biomarkers, their expression must be screened in large collections of patient samples. Here, we develop a scalable protocol for the rapid and economical preparation of a large number of small RNA sequencing libraries using dual indexing for multiplexing. Combined with the use of off-the-shelf reagents, more samples can be sequenced simultaneously on large-scale sequencing platforms at a considerably lower cost per sample. Sample preparation is simplified by pooling libraries prior to gel purification, which allows for the selection of a narrow size range while minimizing sample variation. A comparison with publicly available data from benchmarking of miRNA analysis platforms showed that this method captures absolute and differential expression as effectively as commercially available alternatives.
Formulation of colchicine ointment for the treatment of acute gout.
Maduri, Sairam; Atla, Venkateshwar Reddy
2012-11-01
In spite of being the fastest acting drug available for the control of an acute gout attack, colchicine is generally considered a last alternative in gout therapy. This is mainly due to the severe adverse effects associated with its administration through the enteral and parenteral routes, as well as its high risk/benefit ratio. The preparation of dosage forms of colchicine that can be administered by alternative routes is therefore a beneficial exercise. Among the formulable substitute dosage forms of colchicine, its ointment seems to be the best option available due to its ability to deliver the drug transdermally as well as its ease of preparation and evaluation. In this study, we prepared and tested 0.2% and 0.5% colchicine ointments for their effectiveness in delivering colchicine transdermally. Colchicine ointment was prepared using a self-formulated water-in-oil type of emulsion ointment base, with the colchicine dissolved in the water portion of the ointment base. In vitro drug release studies were carried out using the Franz diffusion test apparatus and an ultraviolet (UV)-visible spectrophotometer was used to quantify the drug in the samples. Rabbits were used as test animals for in vivo studies and the blood samples were analysed using the UV-visible spectrophotometer. Colchicine was found to be well-absorbed transdermally, although absorption was not 100%. No side effects were associated with its 0.2% formulation. Ointments containing colchicine in low concentrations may be a feasible and effective treatment option for the prevention and treatment of acute gout attacks.
Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C
2016-01-28
Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. Copyright © 2015 Elsevier B.V. All rights reserved.
Adaptive Insecure Attachment and Resource Control Strategies during Middle Childhood
ERIC Educational Resources Information Center
Chen, Bin-Bin; Chang, Lei
2012-01-01
By integrating the life history theory of attachment with resource control theory, the current study examines the hypothesis that insecure attachment styles reorganized in middle childhood are alternative adaptive strategies used to prepare for upcoming competition with the peer group. A sample of 654 children in the second through seventh grades…
Videvall, Elin; Strandh, Maria; Engelbrecht, Anel; Cloete, Schalk; Cornwallis, Charlie K
2017-01-01
The gut microbiome of animals is emerging as an important factor influencing ecological and evolutionary processes. A major bottleneck in obtaining microbiome data from large numbers of samples is the time-consuming laboratory procedures required, specifically the isolation of DNA and generation of amplicon libraries. Recently, direct PCR kits have been developed that circumvent conventional DNA extraction steps, thereby streamlining the laboratory process by reducing preparation time and costs. However, the reliability and efficacy of direct PCR for measuring host microbiomes have not yet been investigated other than in humans with 454 sequencing. Here, we conduct a comprehensive evaluation of the microbial communities obtained with direct PCR and the widely used Mo Bio PowerSoil DNA extraction kit in five distinct gut sample types (ileum, cecum, colon, feces, and cloaca) from 20 juvenile ostriches, using 16S rRNA Illumina MiSeq sequencing. We found that direct PCR was highly comparable over a range of measures to the DNA extraction method in cecal, colon, and fecal samples. However, the two methods significantly differed in samples with comparably low bacterial biomass: cloacal and especially ileal samples. We also sequenced 100 replicate sample pairs to evaluate repeatability during both extraction and PCR stages and found that both methods were highly consistent for cecal, colon, and fecal samples ( r s > 0.7) but had low repeatability for cloacal ( r s = 0.39) and ileal ( r s = -0.24) samples. This study indicates that direct PCR provides a fast, cheap, and reliable alternative to conventional DNA extraction methods for retrieving 16S rRNA data, which can aid future gut microbiome studies. IMPORTANCE The microbial communities of animals can have large impacts on their hosts, and the number of studies using high-throughput sequencing to measure gut microbiomes is rapidly increasing. However, the library preparation procedure in microbiome research is both costly and time-consuming, especially for large numbers of samples. We investigated a cheaper and faster direct PCR method designed to bypass the DNA isolation steps during 16S rRNA library preparation and compared it with a standard DNA extraction method. We used both techniques on five different gut sample types collected from 20 juvenile ostriches and sequenced samples with Illumina MiSeq. The methods were highly comparable and highly repeatable in three sample types with high microbial biomass (cecum, colon, and feces), but larger differences and low repeatability were found in the microbiomes obtained from the ileum and cloaca. These results will help microbiome researchers assess library preparation procedures and plan their studies accordingly.
Shao, Fangjie; Jiang, Wenhong; Gao, Qingqing; Li, Baizhou; Sun, Chongran; Wang, Qiyuan; Chen, Qin; Sun, Bing; Shen, Hong; Zhu, Keqing; Zhang, Jianmin; Liu, Chong
2017-10-01
The availability of a comprehensive tissue library is essential for elucidating the function and pathology of human brains. Considering the irreplaceable status of the formalin-fixation-paraffin-embedding (FFPE) preparation in routine pathology and the advantage of ultra-low temperature to preserve nucleic acids and proteins for multi-omics studies, these methods have become major modalities for the construction of brain tissue libraries. Nevertheless, the use of FFPE and snap-frozen samples is limited in high-resolution histological analyses because the preparation destroys tissue integrity and/or many important cellular markers. To overcome these limitations, we detailed a protocol to prepare and analyze frozen human brain samples that is particularly suitable for high-resolution multiplex immunohistological studies. As an alternative, we offered an optimized procedure to rescue snap-frozen tissues for the same purpose. Importantly, we provided a guideline to construct libraries of frozen tissue with minimal effort, cost and space. Taking advantage of this new tissue preparation modality to nicely preserve the cellular information that was otherwise damaged using conventional methods and to effectively remove tissue autofluorescence, we described the high-resolution landscape of the cellular composition in both lower-grade gliomas and glioblastoma multiforme samples. Our work showcases the great value of fixed frozen tissue in understanding the cellular mechanisms of CNS functions and abnormalities.
Ashley, Jon; Shahbazi, Mohammad-Ali; Kant, Krishna; Chidambara, Vinayaka Aaydha; Wolff, Anders; Bang, Dang Duong; Sun, Yi
2017-05-15
Molecularly imprinted polymers (MIPs) are biomimetics which can selectively bind to analytes of interest. One of the most interesting areas where MIPs have shown the biggest potential is food analysis. MIPs have found use as sorbents in sample preparation attributed to the high selectivity and high loading capacity. MIPs have been intensively employed in classical solid-phase extraction and solid-phase microextraction. More recently, MIPs have been combined with magnetic bead extraction, which greatly simplifies sample handling procedures. Studies have consistently shown that MIPs can effectively minimize complex food matrix effects, and improve recoveries and detection limits. In addition to sample preparation, MIPs have also been viewed as promising alternatives to bio-receptors due to the inherent molecular recognition abilities and the high stability in harsh chemical and physical conditions. MIPs have been utilized as receptors in biosensing platforms such as electrochemical, optical and mass biosensors to detect various analytes in food. In this review, we will discuss the current state-of-the-art of MIP synthesis and applications in the context of food analysis. We will highlight the imprinting methods which are applicable for imprinting food templates, summarize the recent progress in using MIPs for preparing and analysing food samples, and discuss the current limitations in the commercialisation of MIPs technology. Finally, future perspectives will be given. Copyright © 2017 Elsevier B.V. All rights reserved.
1987-10-01
Facilities" (A-65) Summary: Samples of the coating systems prepared for NCEL performance prediction studies were tested by alternate immersion in salt...coating sample where the yeast growth is inhibited over a 72-hour period. 5 - .. -, a . - - tL .naa t ~ ~S ~* r* J.r~ ¶Sf ~ ~t~ 9n~ PbP. bPjht fLMM...which is employed as a means of measuring the decibels of attenuation of the echoes caused by the sample on the line. The exponential decay of the
Suspensions as a Valuable Alternative to Extemporaneously Compounded Capsules.
Dijkers, Eli; Nanhekhan, Valerie; Thorissen, Astrid; Polonini, Hudson
2017-01-01
The objective of this study was to determine the variation in content of 74 different active pharmaceutical ingredients (APIs) and compare it with what is known in the literature for the content uniformity of extemporaneous prepared capsules. Active pharmaceutical ingredients quantification was performed by high-performance liquid chromatography, via a stability-indicating method. Samples for all active pharmaceutical ingredients were taken throughout a 90-day period and the content was determined. In total, 5,190 different samples were analyzed for 74 different active pharmaceutical ingredients at room (15°C to 25°C) or controlled refrigerated temperature (2°C to 8°C). Each of these datasets was analyzed according to the United States Pharmacopeia Content Uniformity monograph, corrected for the sample number. The mean acceptance values were well within specifications. In addition, all suspensions complied with the criteria defined by the British Pharmacopoeia monograph for Content Uniformity of Liquid Dispersions for both room and controlled refrigerated temperature. In previous studies, it was found that a routine weight variation check is often not sufficient for quality assurance of extemporaneous prepared capsules. Compounded oral liquids show little variation in content for 74 different active pharmaceutical ingredients; therefore, compounded oral liquids are a suitable alternative when compounding individualized medications for patients. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Sudhakaran, R; Mekata, T; Kono, T; Supamattaya, K; Linh, N T H; Suzuki, Y; Sakai, M; Itami, T
2009-07-01
White spot syndrome virus (WSSV) is an important shrimp pathogen responsible for large economic losses for the shrimp culture industry worldwide. The nucleic acids of the virus must be adequately preserved and transported from the field to the laboratory before molecular diagnostic analysis is performed. Here, we developed a new method to isolate WSSV-DNA using Flinders Technology Associates filter paper (FTA matrix card; Whatman) without centrifugation or hazardous steps involved. FTA technology is a new method allowing the simple collection, shipment and archiving of nucleic acids from haemolymph samples providing DNA protection against nucleases, oxidation, UV damage, microbial and fungal attack. DNA samples prepared from 10-fold dilutions of moribund shrimp haemolymph using FTA matrix cards were analysed using semi-quantitative and quantitative polymerase chain reaction (PCR) and were compared with two commercially available DNA isolation methods, the blood GenomicPrep Mini Spin Kit (GE Healthcare) and the DNAzol (Invitrogen). Sequence analysis was performed for the DNA samples prepared using the various isolation procedures and no differences in the sequence among these methods were identified. Results based on the initial copy number of DNA prepared from the GenomicPrep Mini Spin Kit are a little more sensitive than the DNA prepared from FTA matrix cards, whereas the DNAzol method is not suitable for blood samples. Our data shows the efficiency of retention capacity of WSSV-DNA samples from impregnated FTA matrix cards. Matrix cards were easy to store and ship for long periods of time. They provide ease of handling and are a reliable alternative for sample collection and for molecular detection and characterization of WSSV isolates.
Niss, Frida; Rosenmai, Anna Kjerstine; Mandava, Geeta; Örn, Stefan; Oskarsson, Agneta; Lundqvist, Johan
2018-04-01
The use of in vitro bioassays for studies of toxic activity in environmental water samples is a rapidly expanding field of research. Cell-based bioassays can assess the total toxicity exerted by a water sample, regardless whether the toxicity is caused by a known or unknown agent or by a complex mixture of different agents. When using bioassays for environmental water samples, it is often necessary to concentrate the water samples before applying the sample. Commonly, water samples are concentrated 10-50 times. However, there is always a risk of losing compounds in the sample in such sample preparation. We have developed an alternative experimental design by preparing a concentrated cell culture medium which was then diluted in the environmental water sample to compose the final cell culture media for the in vitro assays. Water samples from five Swedish waste water treatment plants were analyzed for oxidative stress response, estrogen receptor (ER), and aryl hydrocarbon receptor (AhR) activity using this experimental design. We were able to detect responses equivalent to 8.8-11.3 ng/L TCCD for AhR activity and 0.4-0.9 ng/L 17β-estradiol for ER activity. We were unable to detect oxidative stress response in any of the studied water samples. In conclusion, we have developed an experimental design allowing us to examine environmental water samples in toxicity in vitro assays at a concentration factor close to 1, without the risk of losing known or unknown compounds during an extraction procedure.
Leung, Yu Hang; Guo, Mu Yao; Ma, Angel P Y; Ng, Alan M C; Djurišić, Aleksandra B; Degger, Natalie; Leung, Frederick C C
2017-07-01
We investigated transmission electron microscopy artifacts obtained using standard sample preparation protocols applied to the investigation of Escherichia coli cells exposed to common nanomaterials, such as TiO 2 , Ag, ZnO, and MgO. While the common protocols for some nanomaterials result only in known issues of nanomaterial-independent generation of anomalous deposits due to fixation and staining, for others, there are reactions between the nanomaterial and chemicals used for post-fixation or staining. Only in the case of TiO 2 do we observe only the known issues of nanomaterial-independent generation of anomalous deposits due to exceptional chemical stability of this material. For the other three nanomaterials, different artifacts are observed. For each of those, we identify causes of the observed problems and suggest alternative sample preparation protocols to avoid artifacts arising from the sample preparation, which is essential for correct interpretation of the obtained images and drawing correct conclusions on cell-nanomaterial interactions. Finally, we propose modified sample preparation and characterization protocols for comprehensive and conclusive investigations of nanomaterial-cell interactions using electron microscopy and for obtaining clear and unambiguous revelation whether the nanomaterials studied penetrate the cells or accumulate at the cell membranes. In only the case of MgO and ZnO, the unambiguous presence of Zn and Mg could be observed inside the cells.
Thermal Stress Effect on Density Changes of Hemp Hurds Composites
NASA Astrophysics Data System (ADS)
Schwarzova, Ivana; Cigasova, Julia; Stevulova, Nadezda
2016-12-01
The aim of this article is to study the behavior of prepared biocomposites based on hemp hurds as a filling agent in composite system. In addition to the filler and water, an alternative binder, called MgO-cement was used. For this objective were prepared three types of samples; samples based on untreated hemp hurds as a referential material and samples based on chemically (with NaOH solution) and physically (by ultrasonic procedure) treated hemp hurds. The thermal stress effect on bulk density changes of hemp hurds composites was monitored. Gradual increase in temperature led to composites density reduction of 30-40 %. This process is connected with mass loss of the adsorbed moisture and physically bound water and also with degradation of organic compounds present in hemp hurds aggregates such as pectin, hemicelluloses and cellulose. Therefore the changes in the chemical composition of treated hemp hurds in comparison to original sample and its thermal decomposition were also studied.
Lelental, Natalia; Brandner, Sebastian; Kofanova, Olga; Blennow, Kaj; Zetterberg, Henrik; Andreasson, Ulf; Engelborghs, Sebastiaan; Mroczko, Barbara; Gabryelewicz, Tomasz; Teunissen, Charlotte; Mollenhauer, Brit; Parnetti, Lucilla; Chiasserini, Davide; Molinuevo, Jose Luis; Perret-Liaudet, Armand; Verbeek, Marcel M; Andreasen, Niels; Brosseron, Frederic; Bahl, Justyna M C; Herukka, Sanna-Kaisa; Hausner, Lucrezia; Frölich, Lutz; Labonte, Anne; Poirier, Judes; Miller, Anne-Marie; Zilka, Norbert; Kovacech, Branislav; Urbani, Andrea; Suardi, Silvia; Oliveira, Catarina; Baldeiras, Ines; Dubois, Bruno; Rot, Uros; Lehmann, Sylvain; Skinningsrud, Anders; Betsou, Fay; Wiltfang, Jens; Gkatzima, Olymbia; Winblad, Bengt; Buchfelder, Michael; Kornhuber, Johannes; Lewczuk, Piotr
2016-03-01
Assay-vendor independent quality control (QC) samples for neurochemical dementia diagnostics (NDD) biomarkers are so far commercially unavailable. This requires that NDD laboratories prepare their own QC samples, for example by pooling leftover cerebrospinal fluid (CSF) samples. To prepare and test alternative matrices for QC samples that could facilitate intra- and inter-laboratory QC of the NDD biomarkers. Three matrices were validated in this study: (A) human pooled CSF, (B) Aβ peptides spiked into human prediluted plasma, and (C) Aβ peptides spiked into solution of bovine serum albumin in phosphate-buffered saline. All matrices were tested also after supplementation with an antibacterial agent (sodium azide). We analyzed short- and long-term stability of the biomarkers with ELISA and chemiluminescence (Fujirebio Europe, MSD, IBL International), and performed an inter-laboratory variability study. NDD biomarkers turned out to be stable in almost all samples stored at the tested conditions for up to 14 days as well as in samples stored deep-frozen (at - 80°C) for up to one year. Sodium azide did not influence biomarker stability. Inter-center variability of the samples sent at room temperature (pooled CSF, freeze-dried CSF, and four artificial matrices) was comparable to the results obtained on deep-frozen samples in other large-scale projects. Our results suggest that it is possible to replace self-made, CSF-based QC samples with large-scale volumes of QC materials prepared with artificial peptides and matrices. This would greatly facilitate intra- and inter-laboratory QC schedules for NDD measurements.
Hu, Yong; Wu, Hai-Long; Yin, Xiao-Li; Gu, Hui-Wen; Xiao, Rong; Xie, Li-Xia; Liu, Zhi; Fang, Huan; Wang, Li; Yu, Ru-Qin
2018-04-01
The aim of the present work was to develop a rapid and interference-free method based on liquid chromatography-mass spectrometry (LC-MS) for the simultaneous determination of nine B-group vitamins in various energy drinks. A smart and green strategy that modeled the three-way data array of LC-MS with second-order calibration methods based on alternating trilinear decomposition (ATLD) and alternating penalty trilinear decomposition (APTLD) algorithms was developed. By virtue of "mathematical separation" and "second-order advantage", the proposed strategy successfully solved the co-eluted peaks and unknown interferents in LC-MS analysis with the elution time less than 4.5min and simple sample preparation. Satisfactory quantitative results were obtained by the ATLD-LC-MS and APTLD-LC-MS methods for the spiked recovery assays, with the average spiked recoveries ranging from 87.2-113.9% to 92.0-111.7%, respectively. These results acquired from the proposed methods were confirmed by the LC-MS/MS method, which shows a quite good consistency with each other. All these results demonstrated that the developed chemometrics-assisted LC-MS strategy had advantages of being rapid, green, accurate and low-cost, and it could be an attractive alternative for the determination of multiple vitamins in complex food matrices, which required no laborious sample preparation, tedious condition optimization or more sophisticated instrumentations. Copyright © 2017 Elsevier B.V. All rights reserved.
Bahrenburg, Sven; Karow, Anne R; Garidel, Patrick
2015-04-01
Protein therapeutics, including monoclonal antibodies (mAbs), have significant buffering capacity, particularly at concentrations>50 mg/mL. This report addresses pH-related issues critical to adoption of self-buffered monoclonal antibody formulations. We evaluated solution conditions with protein concentrations ranging from 50 to 250 mg/mL. Samples were both buffer-free and conventionally buffered with citrate. Samples were non-isotonic or adjusted for isotonicity with NaCl or trehalose. Studies included accelerated temperature stability tests, shaking stability studies, and pH changes in infusion media as protein concentrate is added. We present averaged buffering slopes of capacity that can be applied to any mAb and present a general method for calculating buffering capacity of buffer-free, highly concentrated antibody liquid formulations. In temperature stability tests, neither buffer-free nor conventionally buffered solution conditions showed significant pH changes. Conventionally buffered solutions showed significantly higher opalescence than buffer-free ones. In general, buffer-free solution conditions showed less aggregation than conventionally buffered solutions. Shaking stability tests showed no differences between buffer-free and conventionally buffered solutions. "In-use" preparation experiments showed that pH in infusion bag medium can rapidly approximate that of self-buffered protein concentrate as concentrate is added. In summary, the buffer capacity of proteins can be predicted and buffer-free therapeutic antibody preparations provide a viable alternative to conventionally buffered solutions. Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Porojan, Sorin; Bîrdeanu, Mihaela; Savencu, Cristina; Porojan, Liliana
2017-08-01
The integration of digitalized processing technologies in traditional dental restorations manufacturing is an emerging application. The objective of this study was to identify the different structural and morphological characteristics of Co-Cr dental alloys processed by alternative manufacturing techniques in order to understand the influence of microstructure on restorations properties and their clinical behavior. Metallic specimens made of Co-Cr dental alloys were prepared using traditional casting (CST), and computerized milling (MIL), selective laser sintering (SLS) and selective laser melting (SLM). The structural information of the samples was obtained by X-ray diffraction, the morphology and the topography of the samples were investigated by Scanning Electron Microscopy and Atomic Force Microscope. Given that the microstructure was significantly different, further differences in the clinical behavior of prosthetic restorations manufactured using additive techniques are anticipated.
Zhuang, H; Savage, E M
2008-10-01
Quality assessment results of cooked meat can be significantly affected by sample preparation with different cooking techniques. A combi oven is a relatively new cooking technique in the U.S. market. However, there was a lack of published data about its effect on quality measurements of chicken meat. Broiler breast fillets deboned at 24-h postmortem were cooked with one of the 3 methods to the core temperature of 80 degrees C. Cooking methods were evaluated based on cooking operation requirements, sensory profiles, Warner-Bratzler (WB) shear and cooking loss. Our results show that the average cooking time for the combi oven was 17 min compared with 31 min for the commercial oven method and 16 min for the hot water method. The combi oven did not result in a significant difference in the WB shear force values, although the cooking loss of the combi oven samples was significantly lower than the commercial oven and hot water samples. Sensory profiles of the combi oven samples did not significantly differ from those of the commercial oven and hot water samples. These results demonstrate that combi oven cooking did not significantly affect sensory profiles and WB shear force measurements of chicken breast muscle compared to the other 2 cooking methods. The combi oven method appears to be an acceptable alternative for preparing chicken breast fillets in a quality assessment.
Renewal, Resurgence, and Alternative Reinforcement Context
Sweeney, Mary M.; Shahan, Timothy A.
2015-01-01
Resurgence, relapse induced by the removal of alternative reinforcement, and renewal, relapse induced by a change in contextual stimuli, are typically studied separately in operant conditioning paradigms. In analogous treatments of operant problem behavior, aspects of both relapse phenomena can operate simultaneously. Therefore, the purpose of this study was to examine a novel method for studying resurgence and renewal in the same experimental preparation. An alternative source of reinforcement was available during extinction for one group of rats (a typical resurgence preparation). Another group experienced an operant renewal preparation in which the extinction context was distinguished via olfactory and visual stimuli. A third group experienced alternative reinforcement delivery in the new context, a novel combination of typical resurgence and renewal preparations. Removal of alternative reinforcement and/or a change in context induced relapse, relative to an extinction-only control group. When alternative reinforcement was delivered in a novel context, the alternative response was less persistent relative to when extinction of the alternative response took place in the context in which it was trained. This methodology might be used to illustrate shared (or distinct) mechanisms of resurgence and renewal, and to determine how delivering alternative reinforcement in another context may affect persistence and relapse. PMID:25936876
Beyer, Andreas; Grohganz, Holger; Löbmann, Korbinian; Rades, Thomas; Leopold, Claudia S
2016-12-01
Co-amorphization represents a promising approach to increase the physical stability and dissolution rate of amorphous active pharmaceutical ingredients (APIs) as an alternative to polymer glass solutions. For amorphous and co-amorphous systems, it is reported that the preparation method and the blend ratio play major roles with regard to the resulting physical stability. Therefore, in the present study, co-amorphous naproxen-indomethacin (NAP/IND) was prepared by melt-quenching at three different cooling rates and at ten different NAP/IND blend ratios. The samples were analyzed using XRPD and FTIR, both directly after preparation and during storage to investigate their physical stabilities. All cooling methods led to fully amorphous samples, but with significantly different physical stabilities. Samples prepared by fast cooling had a higher degree of crystallinity after 300d of storage than samples prepared by intermediate cooling and slow cooling. Intermediate cooling was subsequently used to prepare co-amorphous NAP/IND at different blend ratios. In a previous study, it was postulated that the equimolar (0.5:0.5) co-amorphous blend of NAP/IND is most stable. However, in the present study the physically most stable blend was found for a NAP/IND ratio of 0.6:0.4, which also represents the eutectic composition of the crystalline NAP/γ-IND system. This indicates that the eutectic point may be of major importance for the stability of binary co-amorphous systems. Slight deviations from the optimal naproxen molar fraction led to significant recrystallization during storage. Either naproxen or γ-indomethacin recrystallized until a naproxen molar fraction of about 0.6 in the residual co-amorphous phase was reached again. In conclusion, the physical stability of co-amorphous NAP/IND may be significantly improved, if suitable preparation conditions and the optimal phase composition are chosen. Copyright © 2016 Elsevier B.V. All rights reserved.
Criado-García, Laura; Garrido-Delgado, Rocío; Arce, Lourdes; Valcárcel, Miguel
2013-07-15
An UV-Ion Mobility Spectrometer is a simple, rapid, inexpensive instrument widely used in environmental analysis among other fields. The advantageous features of its underlying technology can be of great help towards developing reliable, economical methods for determining gaseous compounds from gaseous, liquid and solid samples. Developing an effective method using UV-Ion Mobility Spectrometry (UV-IMS) to determine volatile analytes entails using appropriate gaseous standards for calibrating the spectrometer. In this work, two home-made sample introduction systems (SISs) and a commercial gas generator were used to obtain such gaseous standards. The first home-made SIS used was a static head-space to measure compounds present in liquid samples and the other home-made system was an exponential dilution set-up to measure compounds present in gaseous samples. Gaseous compounds generated by each method were determined on-line by UV-IMS. Target analytes chosen for this comparative study were ethanol, acetone, benzene, toluene, ethylbenzene and xylene isomers. The different alternatives were acceptable in terms of sensitivity, precision and selectivity. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Venkatachalaiah, K. N.; Nagabhushana, H.; Darshan, G. P.; Basavaraj, R. B.; Daruka Prasad, B.; Sharma, S. C.
2017-09-01
Modified sonochemical route was used to prepare Y2O3:Tm3+ (1-11 mol%) nanophosphor using Mimosa pudica (M.P.) leaves extract as bio-surfactant. The prepared samples were exhibited high crystalline nature with various morphologies. This was due to sonochemical experimental reaction took place between cavitation bubbles and nearby solution. The average crystallite sizes of the prepared samples were about 15 nm to 21 nm as obtained from PXRD and TEM analysis. The ultraviolet visible absorption spectra showed prominent bands with an energy gap varied from 5.73 eV to 5.84 eV. Photoluminescence (PL) emission spectra shows the prominent blue light emission peak at 456 nm attributed to 1D2 → 3F4 transitions of Tm3+ ions. Judd-Ofelt intensity parameters were estimated by using PL emission spectra. The photometric characteristics of the prepared compounds were very close to the blue color of NTSC standards. So the results were fruitful in making use of Y2O3:Tm3 + nanophosphor as an alternative material for effective blue component in WLED's.
Advances in ultrasensitive mass spectrometry of organic molecules.
Kandiah, Mathivathani; Urban, Pawel L
2013-06-21
Ultrasensitive mass spectrometric analysis of organic molecules is important for various branches of chemistry, and other fields including physics, earth and environmental sciences, archaeology, biomedicine, and materials science. It finds applications--as an enabling tool--in systems biology, biological imaging, clinical analysis, and forensics. Although there are a number of technical obstacles associated with the analysis of samples by mass spectrometry at ultratrace level (for example analyte losses during sample preparation, insufficient sensitivity, ion suppression), several noteworthy developments have been made over the years. They include: sensitive ion sources, loss-free interfaces, ion optics components, efficient mass analyzers and detectors, as well as "smart" sample preparation strategies. Some of the mass spectrometric methods published to date can achieve sensitivity which is by several orders of magnitude higher than that of alternative approaches. Femto- and attomole level limits of detection are nowadays common, while zepto- and yoctomole level limits of detection have also been reported. We envision that the ultrasensitive mass spectrometric assays will soon contribute to new discoveries in bioscience and other areas.
Jiménez-Díaz, I; Vela-Soria, F; Rodríguez-Gómez, R; Zafra-Gómez, A; Ballesteros, O; Navalón, A
2015-09-10
In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs -substances able to alter the normal hormone function of wildlife and humans-. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid-liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of hydroxyapatite and dental enamel for testing shear bond strengths.
Imthiaz, Nishat; Georgiou, George; Moles, David R; Jones, Steven P
2008-05-01
To investigate the feasibility of using artificial hydroxyapatite as a future biomimetic laboratory substitute for human enamel in orthodontic bond strength testing by comparing the shear bond strengths and nature of failure of brackets bonded to samples of hydroxyapatite and enamel. One hundred and fifty hydroxyapatite discs were prepared by compression at 20 tons and fired in a furnace at 1300 degrees C. One hundred and five enamel samples were prepared from the buccal and palatal/lingual surfaces of healthy premolars extracted for orthodontic purposes. Orthodontic brackets were bonded to each sample and these were subjected to shear bond strength testing using a custom-made jig mounted in an Instron Universal Testing Machine. The force value at bond failure was obtained, together with the nature of failure which was assessed using the Adhesive Remnant Index. The mean shear bond strength for the enamel samples was 16.62 MPa (95 per cent CI: 15.26, 17.98) and for the hydroxyapatite samples 20.83 MPa (95 per cent CI: 19.68, 21.98). The difference between the two samples was statistically significant (p < 0.001). When the nature of failure was assessed with the ARI Index, 83 per cent of the enamel samples scored 2 or 3, while 49 per cent of the hydroxyapatite samples scored 0 or 1. Hydroxyapatite was an effective biomimetic substrate for bond strength testing with a mean shear bond strength value (20.83 MPa) at the upper end of the normal range attributed to enamel (15-20 MPa). Although the difference between the shear bond strengths for hydroxyapatite and enamel was statistically significant, hydroxyapatite could be used as an alternative to enamel for comparative laboratory studies until a closer alternative is found. This would eliminate the need for extracted teeth to be collected. However, it should be used with caution for quantitative studies where true bond strengths are to be investigated.
Assessing the Potential of Metal-Assisted Imaging Mass Spectrometry in Cancer Research.
Dufresne, M; Patterson, N H; Lauzon, N; Chaurand, P
2017-01-01
In the last decade, imaging mass spectrometry (IMS) has been the primary tool for biomolecular imaging. While it is possible to map a wide range of biomolecules using matrix-assisted laser desorption/ionization IMS ranging from high-molecular-weight proteins to small metabolites, more often than not only the most abundant easily ionisable species are detected. To better understand complex diseases such as cancer more specific and sensitive methods need to be developed to enable the detection of lower abundance molecules but also molecules that have yet to be imaged by IMS. In recent years, a big shift has occurred in the imaging community from developing wide reaching methods to developing targeted ones which increases sensitivity through the use of more specific sample preparations. This has been primarily marked by the advent of solvent-free matrix deposition methods for polar lipids, chemical derivatization for hormones and metabolites, and the use of alternative ionization agents for neutral lipids. In this chapter, we discuss two of the latest sample preparations which exploit the use of alternative ionization agents to enable the detection of certain classes of neutral lipids along with free fatty acids by high-sensitivity IMS as demonstrated within our lab. © 2017 Elsevier Inc. All rights reserved.
Comparison of hard tissues that are useful for DNA analysis in forensic autopsy.
Kaneko, Yu; Ohira, Hiroshi; Tsuda, Yukio; Yamada, Yoshihiro
2015-11-01
Forensic analysis of DNA from hard tissues can be important when investigating a variety of cases resulting from mass disaster or criminal cases. This study was conducted to evaluate the most suitable tissues, method and sample size for processing of hard tissues prior to DNA isolation. We also evaluated the elapsed time after death in relation to the quantity of DNA extracted. Samples of hard tissues (37 teeth, 42 skull, 42 rib, and 39 nails) from 42 individuals aged between 50 and 83 years were used. The samples were taken from remains following forensic autopsy (from 2 days to 2 years after death). To evaluate the integrity of the nuclear DNA isolated, the percentage of allele calls for short tandem repeat profiles were compared between the hard tissues. DNA typing results indicated that until 1 month after death, any of the four hard tissue samples could be used as an alternative to teeth, allowing analysis of all of the loci. However, in terms of the sampling site, collection method and sample size adjustment, the rib appeared to be the best choice in view of the ease of specimen preparation. Our data suggest that the rib could be an alternative hard tissue sample for DNA analysis of human remains. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Cost Effectiveness of Alternative Route Special Education Teacher Preparation
ERIC Educational Resources Information Center
Sindelar, Paul T.; Dewey, James F.; Rosenberg, Michael S.; Corbett, Nancy L.; Denslow, David; Lotfinia, Babik
2012-01-01
In this study, the authors estimated costs of alternative route preparation to provide states a basis for allocating training funds to maximize production. Thirty-one special education alternative route program directors were interviewed and completed cost tables. Two hundred and twenty-four program graduates were also surveyed. The authors…
Huber, Alexander; France, Richard M; Riccalton-Banks, Lisa; McLaren, Jane; Cox, Helen; Quirk, Robin A; Shakesheff, Kevin M; Thompson, David; Panjwani, Naveed; Shipley, Sarah; Pickett, Andy
2008-05-01
Therapeutic botulinum neurotoxin type A preparations have found an increasing number of clinical uses for a large variety of neuromuscular disorders and dermatological conditions. The accurate determination of potency in the clinical application of botulinum toxins is critical to ensuring clinical efficacy and safety, and is currently achieved by using a lethal dose (LD50) assay in mice. Ethical concerns and operational constraints associated with this assay have prompted the development of alternative assay systems that could potentially lead to its replacement. As one such alternative, we describe the development and evaluation of a novel ex vivo assay (the Intercostal Neuromuscular Junction [NMJ] Assay), which uses substantially fewer animals and addresses ethical concerns associated with the LD50 assay. The assay records the decay of force from electrically-stimulated muscle tissue sections in response to the toxin, and thus combines the important mechanisms of receptor binding, translocation, and the enzymatic action of the toxin molecule. Toxin application leads to a time-related and dose-related reduction in contractile force. A regression model describing the relationship between the applied dose and force decay was determined statistically, and was successfully tested as able to correctly predict the potency of an unknown sample. The tissue sections used were found to be highly reproducible, as determined through the innervation pattern and the localisation of NMJs in situ. Furthermore, the efficacy of the assay protocol to successfully deliver the test sample to the cellular target sites, was critically assessed by using molecular tracer molecules.
Flat ion milling: a powerful tool for preparation of cross-sections of lead-silver alloys.
Brodusch, Nicolas; Boisvert, Sophie; Gauvin, Raynald
2013-06-01
While conventional mechanical and chemical polishing results in stress, deformation and polishing particles embedded on the surface, flat milling with Ar+ ions erodes the material with no mechanical artefacts. This flat milling process is presented as an alternative method to prepare a Pb-Ag alloy cross-section for scanning electron microscopy. The resulting surface is free of scratches with very little to no stress induced, so that electron diffraction and channelling contrast are possible. The results have shown that energy dispersive spectrometer (EDS) mapping, electron channelling contrast imaging and electron backscatter diffraction can be conducted with only one sample preparation step. Electron diffraction patterns acquired at 5 keV possessed very good pattern quality, highlighting an excellent surface condition. An orientation map was acquired at 20 keV with an indexing rate of 90.1%. An EDS map was performed at 5 keV, and Pb-Ag precipitates of sizes lower than 100 nm were observed. However, the drawback of the method is the generation of a noticeable surface topography resulting from the interaction of the ion beam with a polycrystalline and biphasic sample.
Easily recycled Bi2O3 photocatalyst coatings prepared via ball milling followed by calcination
NASA Astrophysics Data System (ADS)
Cheng, Lijun; Hu, Xumin; Hao, Liang
2017-06-01
Bi2O3 photocatalyst coatings derived from Bi coatings were first prepared by a two-step method, namely ball milling followed by the calcination process. The as-prepared samples were characterized by XRD, SEM, XPS and UV-Vis spectra, respectively. The results showed that monoclinic Bi2O3 coatings were obtained after sintering Bi coatings at 673 or 773 K, while monoclinic and triclinic mixed phase Bi2O3 coatings were obtained at 873 or 973 K. The topographies of the samples were observably different, which varied from flower-like, irregular, polygonal to nanosized particles with the increase in calcination temperature. Photodegradation of malachite green under simulated solar irradiation for 180 min showed that the largest degradation efficiency of 86.2% was achieved over Bi2O3 photocatalyst coatings sintered at 873 K. The Bi2O3 photocatalyst coatings, encapsulated with Al2O3 ball with an average diameter around 1 mm, are quite easily recycled, which provides an alternative visible light-driven photocatalyst suitable for practical water treatment application.
Evaluating the Effectiveness of Traditional and Alternative Principal Preparation Programs
ERIC Educational Resources Information Center
Pannell, Summer; Peltier-Glaze, Bernnell M.; Haynes, Ingrid; Davis, Delilah; Skelton, Carrie
2015-01-01
This study sought to determine the effectiveness on increasing student achievement of principals trained in a traditional principal preparation program and those trained in an alternate route principal preparation program within the same Mississippi university. Sixty-six Mississippi principals and assistant principals participated in the study. Of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strmcnik, D.; Hodnik, N.; Hocevar, S. B.
2010-02-18
A carbon fiber microelectrode (CFME) was used for characterization of the nanoparticle catalysts as an alternative to the well-established rotating disk electrode (RDE) method. We found that the novel CFME method yielded comparable results to the RDE method when investigating the adsorption/desorption processes as well the specific activity for reactions such as the oxygen reduction reaction. Its major advantage over the RDE method is a fast sample preparation and rapid measurement, reducing significantly the time of a single sample characterization from 2-3 h to a favorable 5-10 min.
Baghdady, Yehia Z; Schug, Kevin A
2016-01-01
Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Alternative Routes to Teaching: Mapping the New Landscape of Teacher Education
ERIC Educational Resources Information Center
Grossman, Pam, Ed.; Loeb, Susanna, Ed.
2008-01-01
Over the past 20 years, alternative certification for teachers has emerged as a major avenue of teacher preparation. The proliferation of new pathways has spurred heated debate over how best to recruit, prepare, and support qualified teachers. "Alternative Routes to Teaching" provides a thorough and dispassionate review of the research evidence on…
Research and Development for Continued Performance Improvement in Flexible a-Si PV
2010-12-14
accomplished, however, at low temperatures silicides tend to form on the surface of the filament, which affected filament lifetime and deposition rate...considered. Titanium Nitride, sputtered As an alternative to the hot wire deposition of silicon, samples were prepared with various thicknesses of...Silicon 21 Insitu DC Sputtering Titanium Nitride 22 Metal Machine 2 ឈ> RF Oxygen Plasma Silicon Dioxide 20. Oxygen Etch Table A.4.1 Open circuit
McCommis, Kyle S.; Koktzoglou, Ioannis; Zhang, Haosen; Goldstein, Thomas A.; Northrup, Benjamin E.; Li, Debiao; Gropler, Robert J.; Zheng, Jie
2010-01-01
Myocardial oxygen extraction fraction (OEF) during hyperemia can be estimated using a double-inversion-recovery (DIR) prepared T2-weighted black-blood sequence. Severe irregular ECG-triggering due to elevated heart rate and/or arrhythmias may render it difficult to adequately suppress the flowing left ventricle blood signal and thus potentially cause errors in the estimates of myocardial OEF. Thus, the goal of this study was to evaluate another black-blood technique, a diffusion-weighted (DW)-prepared TSE sequence for its ability to determine regional myocardial OEF during hyperemia. Control dogs and dogs with acute coronary artery stenosis were imaged with both the DIR- and DW-prepared TSE sequences at rest and during either dipyridamole or dobutamine hyperemia. Validation of MRI OEF estimates was performed using blood sampling from the artery and coronary sinus in control dogs. The two methods showed comparable correlations with blood sampling results (R2 = 0.9). Similar OEF estimations for all dogs were observed except for the group of dogs with severe coronary stenosis during dobutamine stress. In these dogs, the DW method provided more physiologically reasonable OEF (hyperemic OEF = 0.75 ± 0.08 vs resting OEF of 0.6) than the DIR method (hyperemic OEF = 0.56 ± 0.10). DW-preparation may be a valuable alternative for more accurate oxygenation measurements during irregular ECG-triggering. PMID:20512871
Gamma ray shielding and structural properties of PbO-P2O5-Na2WO4 glass system
NASA Astrophysics Data System (ADS)
Dogra, Mridula; Singh, K. J.; Kaur, Kulwinder; Anand, Vikas; Kaur, Parminder
2017-05-01
The present work has been undertaken to study the gamma ray shielding properties of PbO-P2O5-Na2WO4 glass system. The values of mass attenuation coefficient and half value layer parameter at photon energies 511, 662 and 1173 KeV have been determined using XCOM computer software developed by National Institute of Standards and Technology. The density, molar volume, XRD, UV-VIS and Raman studies have been performed to study the structural properties of the prepared glass system to check the possibility of the use of prepared samples as an alternate to conventional concrete for gamma ray shielding applications.
Using Isotope Ratio Infrared Spectrometer to determine δ13C and δ18O of carbonate samples
NASA Astrophysics Data System (ADS)
Smajgl, Danijela; Stöbener, Nils; Mandic, Magda
2017-04-01
The isotopic composition of calcifying organisms is a key tool for reconstruction past seawater temperature and water chemistry. Therefore stable carbon and oxygen isotopes (δ13C and δ18O) in carbonates have been widely used for reconstruction of paleoenvironments. Precise and accurate determination of isotopic composition of carbon (13C) and oxygen (18O) from carbonate sample with proper referencing and data evaluation algorithm presents a challenge for scientists. Mass spectrometry was the only widely used technique for this kind of analysis, but recent advances make laser based spectroscopy a viable alternative. The Thermo Scientific Delta Ray Isotope Ratio Infrared Spectrometer (IRIS) analyzer with the Universal Reference Interface (URI) Connect is one of those alternatives and with TELEDYNE Cetac ASX-7100 autosampler extends the traditional offerings with a system of high precision and throughput of samples. To establish precision and accuracy of measurements and also to develop optimal sample preparation method for measurements with Delta Ray IRIS and URI Connect, IAEA reference materials were used. Preparation is similar to a Gas Bench II method. Carbonate material is added into the vials, flushed with CO2 free synthetic air and acidified with few droplets of 104% H3PO4. Sample amount used for analysis can be as low as 200 μg. Samples are measured after acidification and equilibration time of one hour at 70°C. The CO2 gas generated by reaction is flushed into the variable volume inside the URI Connect through the Nafion based built-in water trap. For this step, carrier gas (CO2 free air) is used to flush the gas from the vial into the variable volume with a maximum volume of 100 ml. A small amount of the sample is then used for automatic concentration determination present in the variable volume. The Thermo Scientific Qtegra Software automatically adjusts any additional dilution of the sample to achieve the desired concentration (usually 400 ppm) in the analyzer. As part of the workflow, reference gas measurements are regularly measured at the same concentration as the sample to allow for automatic drift and linearity correction. With described sample preparation and measurement method, samples are measured with standard deviation less than 0.1‰ δ13C and δ18O, respectively and accuracy of <0.01‰. The system can measure up to 100 samples per day. Equivalent of about 80 µg of pure CO2 gas is needed to complete an analysis. Due to it's small weight and robustness, sample analysis can be performed in the field. Applying new technology of Isotope Ratio Infrared Spectrometers in environmental and paleoenvironmental research can extend the knowledge of complex seawater history and CO2 cycle.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-09
... System Management (TSM), Bus Rapid Transit (BRT), and Commuter Rail. The AA/EIS will be prepared in.... Transportation System Management (TSM) Alternative: A TSM Alternative, which reflects the best that can be done... regulations. The AA/EIS process provides opportunities for the public to comment on the scope of the EIS...
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2007-01-01
Stennis Space Center (SSC), Kennedy Space Center (KSC) and Air Force Space Command (AFSPC) identified particulate emissions and waste generated from the depainting process of steel structures as hazardous materials to be eliminated or reduced. A Potential Alternatives Report, Potential Alternatives Report for Validation of Alternative Low Emission Surface Preparation/Depainting Technologies for Structural Steel, provided a technical analyses of identified alternatives to the current coating removal processes, criteria used to select alternatives for further analysis, and a list of those alternatives recommended for testing. The initial coating removal alternatives list was compiled using literature searches and stakeholder recommendations. The involved project participants initially considered approximately 13 alternatives. In late 2003, core project members selected the following depainting processes to be further evaluated: (1) Plastic Blast Media-Quickstrip(R)-A. (2) Hard Abrasive-Steel-Magic(R). (3) Sponge Blasting-Sponge-Jet(R). (4) Liquid Nitrogen-NItroJet(R). (5) Mechanical Removal with Vacuum Attachment-DESCO and OCM Clean-Air (6) Laser Coating Removal Alternatives were tested in accordance with the Joint Test Protocol for Validation of Alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel, and the Field Evaluation Test Plan for Validation of Alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel. Results of the testing are documented in the Joint Test Report. This Cost-Benefit Analysis (CBA) focuses on the three alternatives (Quickstrip(R)-A, SteelMagic (R), and Sponge-Jet(R)) that were considered viable alternatives for large area operations based on the results of the field demonstration and lab testing. This CBA was created to help participants determine if implementation of the candidate alternatives is economically justified. Each of the alternatives examined reduced Environmental Activity (EA) Costs-those costs associated with complying with environmental regulations. One alternative, Steel-Magic(R), also showed reduced Direct Costs and reduced total costs.
OEO Programs for Migrant and Seasonal Farm Workers. Title IIIB EOA Projects.
ERIC Educational Resources Information Center
Office of Economic Opportunity, Washington, DC.
The major thrust of Title III-B (Economic Opportunity Act) programs is to prepare migrant and seasonal farm workers for upgraded jobs and to prepare entire farm worker families for alternatives to farm work if they so desire. These alternatives, supported through projects for adult heads of households, emphasize skill training in preparation for…
Dickey, Robert W; Plakas, Steven M; Jester, Edward L E; El Said, Kathleen R; Johannessen, Jan N; Flewelling, Leanne J; Scott, Paula; Hammond, Dan G; Van Dolah, Frances M; Leighfield, Tod A; Bottein Dachraoui, Marie-Yasmine; Ramsdell, John S; Pierce, Richard H; Henry, Mike S; Poli, Mark A; Walker, Calvin; Kurtz, Jan; Naar, Jerome; Baden, Daniel G; Musser, Steve M; White, Kevin D; Truman, Penelope; Miller, Aaron; Hawryluk, Timothy P; Wekell, Marleen M; Stirling, David; Quilliam, Michael A; Lee, Jung K
A thirteen-laboratory comparative study tested the performance of four methods as alternatives to mouse bioassay for the determination of brevetoxins in shellfish. The methods were N2a neuroblastoma cell assay, two variations of the sodium channel receptor binding assay, competitive ELISA, and LC/MS. Three to five laboratories independently performed each method using centrally prepared spiked and naturally incurred test samples. Competitive ELISA and receptor binding (96-well format) compared most favorably with mouse bioassay. Between-laboratory relative standard deviations (RSDR) ranged from 10 to 20% for ELISA and 14 to 31% for receptor binding. Within-laboratory (RSDr) ranged from 6 to 15% for ELISA, and 5 to 31% for receptor binding. Cell assay was extremely sensitive but data variation rendered it unsuitable for statistical treatment. LC/MS performed as well as ELISA on spiked test samples but was inordinately affected by lack of toxin-metabolite standards, uniform instrumental parameters, or both, on incurred test samples. The ELISA and receptor binding assay are good alternatives to mouse bioassay for the determination of brevetoxins in shellfish.
Extractive procedure for uranium determination in water samples by liquid scintillation counting.
Gomez Escobar, V; Vera Tomé, F; Lozano, J C; Martín Sánchez, A
1998-07-01
An extractive procedure for uranium determination using liquid scintillation counting with the URAEX cocktail is described. Interference from radon and a strong influence of nitrate ion were detected in this procedure. Interference from radium, thorium and polonium emissions were very low when optimal operating conditions were reached. Quenching effects were considered and the minimum detectable activity was evaluated for different sample volumes. Isotopic analysis of samples can be performed using the proposed method. Comparisons with the results obtained with the general procedure used in alpha spectrometry with passivated implanted planar silicon detectors showed good agreement. The proposed procedure is thus suitable for uranium determination in water samples and can be considered as an alternative to the laborious conventional chemical preparations needed for alpha spectrometry methods using semiconductor detectors.
Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor
2011-09-01
Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.
Microextraction techniques combined with capillary electrophoresis in bioanalysis.
Kohler, Isabelle; Schappler, Julie; Rudaz, Serge
2013-01-01
Over the past two decades, many environmentally sustainable sample-preparation techniques have been proposed, with the objective of reducing the use of toxic organic solvents or substituting these with environmentally friendly alternatives. Microextraction techniques (MEs), in which only a small amount of organic solvent is used, have several advantages, including reduced sample volume, analysis time, and operating costs. Thus, MEs are well adapted in bioanalysis, in which sample preparation is mandatory because of the complexity of a sample that is available in small quantities (mL or even μL only). Capillary electrophoresis (CE) is a powerful and efficient separation technique in which no organic solvents are required for analysis. Combination of CE with MEs is regarded as a very attractive environmentally sustainable analytical tool, and numerous applications have been reported over the last few decades for bioanalysis of low-molecular-weight compounds or for peptide analysis. In this paper we review the use of MEs combined with CE in bioanalysis. The review is divided into two sections: liquid and solid-based MEs. A brief practical and theoretical description of each ME is given, and the techniques are illustrated by relevant applications.
Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications
NASA Astrophysics Data System (ADS)
Finšgar, Matjaž; Uzunalić, Amra Perva; Stergar, Janja; Gradišnik, Lidija; Maver, Uroš
2016-05-01
Corrosion resistance, biocompatibility, improved osteointegration, as well the prevention of inflammation and pain are the most desired characteristics of hip replacement implants. In this study we introduce a novel multi-layered coating on AISI 316LVM stainless steel that shows promise with regard to all mentioned characteristics. The coating is prepared from alternating layers of the biocompatible polysaccharide chitosan and the non-steroid anti-inflammatory drug (NSAID), diclofenac. Electrochemical methods were employed to characterize the corrosion behavior of coated and uncoated samples in physiological solution. It is shown that these coatings improve corrosion resistance. It was also found that these coatings release the incorporated drug in controlled, multi-mechanism manner. Adding additional layers on top of the as-prepared samples, has potential for further tailoring of the release profile and increasing the drug dose. Biocompatibility was proven on human-derived osteoblasts in several experiments. Only viable cells were found on the sample surface after incubation of the samples with the same cell line. This novel coating could prove important for prolongation of the application potential of steel-based hip replacements, which are these days often replaced by more expensive ceramic or other metal alloys.
Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications
Finšgar, Matjaž; Uzunalić, Amra Perva; Stergar, Janja; Gradišnik, Lidija; Maver, Uroš
2016-01-01
Corrosion resistance, biocompatibility, improved osteointegration, as well the prevention of inflammation and pain are the most desired characteristics of hip replacement implants. In this study we introduce a novel multi-layered coating on AISI 316LVM stainless steel that shows promise with regard to all mentioned characteristics. The coating is prepared from alternating layers of the biocompatible polysaccharide chitosan and the non-steroid anti-inflammatory drug (NSAID), diclofenac. Electrochemical methods were employed to characterize the corrosion behavior of coated and uncoated samples in physiological solution. It is shown that these coatings improve corrosion resistance. It was also found that these coatings release the incorporated drug in controlled, multi-mechanism manner. Adding additional layers on top of the as-prepared samples, has potential for further tailoring of the release profile and increasing the drug dose. Biocompatibility was proven on human-derived osteoblasts in several experiments. Only viable cells were found on the sample surface after incubation of the samples with the same cell line. This novel coating could prove important for prolongation of the application potential of steel-based hip replacements, which are these days often replaced by more expensive ceramic or other metal alloys. PMID:27215333
Modified Pechini's method to prepare LaAlO3:RE thermoluminescent materials
NASA Astrophysics Data System (ADS)
Rivera-Montalvo, T.; Morales-Hernandez, A.; Barrera-Angeles, A. A.; Alvarez-Romero, R.; Falcony, C.; Zarate-Medina, J.
2017-11-01
This work presents an alternative method to prepare rare-earth doped lanthanum aluminates materials for thermoluminescent (TL) dosimetry applications. Modified Pechini´s method was using to prepare praseodymium doped LaAlO3 powders. LaAlO3:Pr3+ powders were prepared using La(NO3)3·6H2O, Al(NO3)3·6H2O, Pr(NO3)3·6H2O, citric acid, and ethylene glycol. The solution was heated to 80 °C for its polyesterification reaction. The obtained powders were submitted at different thermal treatment from 700 up to 1600 °C. The structural and morphological characterizations were carried out using X-ray diffraction (XRD) and scanning electron microscopy techniques. TL glow curves of the X-ray irradiated samples showed one peak for europium and praseodymium dopants, meanwhile for powders doped with dysprosium ion showed two peaks. The technique is low cost, faster and it produces homogeneous particles can be used as thermoluminescent phosphors.
The impact of teacher preparation on student achievement in rural secondary schools
NASA Astrophysics Data System (ADS)
Barnes, Shontier Prescott
The primary purpose of this study was to examine significant differences, if any, in student achievement in the area of math and science of students taught by traditionally certified teachers and alternatively certified teachers. This study examined alternatively certified teachers, as identified from through the Georgia TAPP (Teacher Alternative Preparation Program), and traditionally certified teachers in rural high schools in the Central Savannah River Area of Georgia. Student achievement was measured by student scores on the Algebra I and Physical Science End-Of-Course Test, a criterion-referenced test aligned with state adopted curriculum standards. The study utilized frequency distributions, correlations, descriptive statistics, and univariate analysis of variance (ANOVA) to examine the data. Univariate tests were done to find individual differences for each dependent variable. The ANOVA was used for the single dependent (student achievement) and formed comparisons and tracked the effect of the independent variable (teacher preparation), each of which (traditional and alternative) may have a number of levels and may interact to affect the dependent variable. The covariates, the independent variables not manipulated, but still affecting the response, are students' ethnicity, gender, and school socioeconomic status were also analyzed to predict student achievement. KEY WORDS. Teacher Preparation, Student Achievement, Math, Science, Traditionally certified teachers, Alternatively certified teachers, Georgia TAPP (Teacher Alternative Preparation Program), End-Of-Course Test (EOCT), Performance standard.
Cassani, Erica; Cilia, Roberto; Laguna, Janeth; Barichella, Michela; Contin, Manuela; Cereda, Emanuele; Isaias, Ioannis U; Sparvoli, Francesca; Akpalu, Albert; Budu, Kwabena Ofosu; Scarpa, Maria Teresa; Pezzoli, Gianni
2016-06-15
Parkinson's disease (PD) is a progressive neurological condition. Levodopa (LD) is the gold standard therapy for PD patients. Most PD patients in low-income areas cannot afford long-term daily Levodopa therapy. The aim of our study was to investigate if Mucuna pruriens (MP), a legume with high LD content that grows in tropical regions worldwide, might be potential alternative for poor PD patients. We analyzed 25 samples of MP from Africa, Latin America and Asia. We measured the content in LD in various MP preparations (dried, roasted, boiled). LD pharmacokinetics and motor response were recorded in four PD patients, comparing MP vs. LD+Dopa-Decarboxylase Inhibitor (DDCI) formulations. Median LD concentration in dried MP seeds was 5.29%; similar results were obtained in roasted powder samples (5.3%), while boiling reduced LD content up to 70%. Compared to LD+DDCI, MP extract at similar LD dose provided less clinical benefit, with a 3.5-fold lower median AUC. Considering the lack of a DDCI, MP therapy may provide clinical benefit only when content of LD is at least 3.5-fold the standard LD+DDCI. If long-term MP proves to be safe and effective in controlled clinical trials, it may be a sustainable alternative therapy for PD in low-income countries. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Navarre, Berengaria; Perez, Norma A.; Smith, Sarah Toombs
2017-01-01
Based on a successful five-week summer program, we constructed an online alternative to prepare Hispanic students to take the Medical College Admission Test (MCAT). We used input from student premed advisors, students, a faculty mentor, a Verbal Reasoning coach, and the program administrator. Online activities were provided to support the student…
Alternative Programs and the Reform of Teacher Education.
ERIC Educational Resources Information Center
Wisniewski, Richard
1986-01-01
Characteristics of professionally sound alternative preparation programs are discussed in terms of admissions, core courses, faculty and student time, simulation activities, and academic preparation. The Lyndhurst Fellowship Program at the University of Tennessee-Knoxville and Memphis State University is described. (MT)
A procedure for preparing undecalcified and unembedded bone sections for light microscopy.
Mancini, M; Spoliti, M; Botti, F; Ragazzoni, E; Cocchia, D
1997-07-01
We have developed a procedure for light microscopic investigation of undecalcified and unembedded bone sections. Biopsy samples of human metatarsus and femur and rat femur were fixed in aldehydes and sectioned with a cutting machine equipped with a diamond saw blade. Free sections 100-150 microns thick, stained with toluidine blue and von Kossa, did not show artifacts following the cutting, and the spatial relations of mineralized and nonmineralized components remained intact. Compact and trabecular bone, bone marrow and all cell types appeared well preserved and easily recognizable. Our procedure provides a simple and rapid method for preparing bone sections which undergo no chemical treatment other than fixation. This method is a useful alternative to standard histological protocols for studying bone specimens.
Miralles, Pablo; Vrouvaki, Ilianna; Chisvert, Alberto; Salvador, Amparo
2016-07-01
An analytical method for the simultaneous determination of phenethyl alcohol, methylpropanediol, phenylpropanol, caprylyl glycol, and ethylhexylglycerin, which are used as alternative preservatives in cosmetic products, has been developed. The method is based on liquid chromatography with UV spectrophotometric detection after chromophoric derivatization with benzoyl chloride and vortex-assisted liquid-liquid semimicroextraction. Different chromatographic parameters, derivatization conditions, and sample preparation variables were studied. Under optimized conditions, the limits of detection values for the analytes ranged from 0.02 to 0.06µgmL(-1). The method was validated with good recovery values (84-118%) and precision values (3.9-9.5%). It was successfully applied to 10 commercially available cosmetic samples. The good analytical features of the proposed method besides of its environmentally-friendly characteristics, make it useful to carry out the quality control of cosmetic products containing the target compounds as preservative agents. Copyright © 2016 Elsevier B.V. All rights reserved.
Tuglu, Devrim; Yılmaz, Erdal; Yuvanc, Ercan; Erguder, Imge; Kisa, Ucler; Bal, Fatih; Batislam, Ertan
2014-12-30
Citrate, potassium, and calcium levels in Viburnum opulus (V. opulus) and lemon juice were compared to evaluate the usability of V. opulus in mild to moderate level hypocitraturic stone disease. V. opulus and lemon fruits were squeezed in a blender and 10 samples of each of 100 ml were prepared. Citrate, calcium, sodium, potassium, magnesium, and pH levels in these samples were examined. Potassium was found to be statistically significantly higher in V. opulus than that in lemon juice (p = 0.006) whereas sodium (p = 0.004) and calcium (p = 0.008) were found to be lower. There was no difference between them in terms of the amount of magnesium and citrate. Because V. opulus contains citrate as high as lemon juice does and it is a potassium-rich and calciumand sodium-poor fluid, it can be an alternative to pharmaceutical treatment in mild-to-moderate degree hypocitraturic stone patients. These findings should be supported with clinical studies.
Alcaráz, Mirta R; Vera-Candioti, Luciana; Culzoni, María J; Goicoechea, Héctor C
2014-04-01
This paper presents the development of a capillary electrophoresis method with diode array detector coupled to multivariate curve resolution-alternating least squares (MCR-ALS) to conduct the resolution and quantitation of a mixture of six quinolones in the presence of several unexpected components. Overlapping of time profiles between analytes and water matrix interferences were mathematically solved by data modeling with the well-known MCR-ALS algorithm. With the aim of overcoming the drawback originated by two compounds with similar spectra, a special strategy was implemented to model the complete electropherogram instead of dividing the data in the region as usually performed in previous works. The method was first applied to quantitate analytes in standard mixtures which were randomly prepared in ultrapure water. Then, tap water samples spiked with several interferences were analyzed. Recoveries between 76.7 and 125 % and limits of detection between 5 and 18 μg L(-1) were achieved.
[Performance comparison of material tests for cadmium and lead in food contact plastics].
Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Ishii, Rie; Itoh, Yuko; Ohno, Hiroyuki; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kaneko, Reiko; Kawamura, Yoko; Shibata, Hiroshi; Sekido, Haruko; Sonobe, Hironori; Takasaka, Noriko; Tajima, Yoshiyasu; Tanaka, Aoi; Nomura, Chie; Hikida, Akinori; Matsuyama, Sigetomo; Murakami, Ryo; Yamaguchi, Miku; Wada, Takenari; Watanabe, Kazunari; Akiyama, Hiroshi
2014-01-01
Based on the Japanese Food Sanitation Law, the performances of official and alternative material test methods for cadmium (Cd) and lead (Pb) in food contact plastics were compared. Nineteen laboratories participated to an interlaboratory study, and quantified Cd and Pb in three PVC pellets. in the official method, a sample is digested with H2SO4, taken up in HCl, and evaporated to dryness on a water bath, then measured by atomic absorption spectrometry (AAS) or inductively coupled plasma-optical emission spectrometry (ICP-OES). Statistical treatment revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 86-95%, 3.1-9.4% and 8.6-22.1%, respectively. The values of the performance parameters fulfilled the requirements , and the performances met the test specifications. The combination of evaporation to dryness on a hot plate and measurement by AAS or ICP-OES is applicable as an alternative method. However, the trueness and RSDr were inferior to those of the official method. The performance parameters obtained by using the microwave digestion method (MW method) to prepare test solution were better than those of the official method. Thus, the MW method is available as an alternative method. Induced coupled plasma-mass spectrometry (ICP-MS) is also available as an alternative method. However, it is necessary to ensure complete digestion of the sample.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-27
... years. Possible alternatives to the proposed action (license renewal) include no action and reasonable alternative energy sources. The NRC is required by 10 CFR 51.95 to prepare a supplement to the GEIS in...
Performance-based, cost- and time-effective pcb analytical methodology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alvarado, J. S.
1998-06-11
Laboratory applications for the analysis of PCBs (polychlorinated biphenyls) in environmental matrices such as soil/sediment/sludge and oil/waste oil were evaluated for potential reduction in waste, source reduction, and alternative techniques for final determination. As a consequence, new procedures were studied for solvent substitution, miniaturization of extraction and cleanups, minimization of reagent consumption, reduction of cost per analysis, and reduction of time. These new procedures provide adequate data that meet all the performance requirements for the determination of PCBs. Use of the new procedures reduced costs for all sample preparation techniques. Time and cost were also reduced by combining the newmore » sample preparation procedures with the power of fast gas chromatography. Separation of Aroclor 1254 was achieved in less than 6 min by using DB-1 and SPB-608 columns. With the greatly shortened run times, reproducibility can be tested quickly and consequently with low cost. With performance-based methodology, the applications presented here can be applied now, without waiting for regulatory approval.« less
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2005-01-01
Headquarters National Aeronautics and Space Administration (NASA) chartered the Acquisition Pollution Prevention (AP2) Office to coordinate agency activities affecting pollution prevention issues identified during system and component acquisition and sustainment processes. The primary objectives of the AP2 Office are to: (1) Reduce or eliminate the use of hazardous materials (HazMats) or hazardous processes at manufacturing, remanufacturing, and sustainment locations. (2) A void duplication of effort in actions required to reduce or eliminate HazMats through joint center cooperation and technology sharing. This project will identify, evaluate and approve alternative surface preparation technologies for use at NASA and Air Force Space Command (AFSPC) installations. Materials and processes will be evaluated with the goal of selecting those processes that will improve corrosion protection at critical systems, facilitate easier maintenance activity, extend maintenance cycles, eliminate flight hardware contamination and reduce the amount of hazardous waste generated. This Joint Test Protocol (JTP) contains the critical requirements and tests necessary to qualify alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel Applications. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of NASA and Air Force Space Command (AFSPC) participants. The Field Test Plan (FTP), entitled Joint Test Protocol for Validation of Alternative Low Emission Surface Preparation/Depainting Technologies for Structural Steel, prepared by ITB, defines the field evaluation and testing requirements for validating alternative surface preparation/depainting technologies and supplements the JTP.
Green analytical chemistry--theory and practice.
Tobiszewski, Marek; Mechlińska, Agata; Namieśnik, Jacek
2010-08-01
This tutorial review summarises the current state of green analytical chemistry with special emphasis on environmentally friendly sample preparation techniques. Green analytical chemistry is a part of the sustainable development concept; its history and origins are described. Miniaturisation of analytical devices and shortening the time elapsing between performing analysis and obtaining reliable analytical results are important aspects of green analytical chemistry. Solventless extraction techniques, the application of alternative solvents and assisted extractions are considered to be the main approaches complying with green analytical chemistry principles.
Preparation of translationally cold neutral molecules.
Di Domenicantonio, Giulia; Bertsche, Benjamin; Osterwalder, Andreas
2011-01-01
Efforts at EPFL to obtain translationally cold neutral molecules are described. Active deceleration of polar molecules is performed by confining the molecules in moving three-dimensional electrostatic traps, and by appropriately choosing the velocity of those traps. Alternatively, cold molecules can be obtained by velocity filtering. Here, the velocity of the molecules is not changed, but instead the cold molecules are extracted from a thermal sample by using the competition between the electrostatic force and the centrifugal force inside a bent electrostatic guide for polar molecules.
2013-02-07
specific biosurveillance activities as well as clinical applications and alternative versions preformatted and categorized as ‘high-tech’ and ‘low-tech’ and...methodologies. Application for patent protection of this DoD intellectual property is underway. 1::1 . :::.u~~l-1 I ~111VI:::O Leishmaniasis...LHL assay and the need to develop novel and unique sample preparation methodologies. Application for patent protection of this DoD intellectual
Santos, Roseclea Chagas Dos; Pinho, Flaviane Alves de; Passos, Gabriela Porfírio; Larangeira, Daniela Farias; Barrouin-Melo, Stella Maria
2018-06-15
The most commonly used culture medium for the in vitro isolation of Leishmania spp. from canine biological samples is biphasic Novy-MacNeal-Nicolle (NNN) medium, whose solid phase is prepared using rabbit blood. Leishmania infantum parasites from natural infections are highly sensitive and demanding for growth in axenic conditions when firstly obtained from the dog's body. The objective of this study was to evaluate whether NNN medium (NNN-test) prepared with chicken blood (NNN-C), ox blood (NNN-O), horse blood (NNN-H) or sheep blood (NNN-S) was viable for the isolation of parasites from naturally infected dogs, in an endemic area for visceral leishmaniasis caused by L. infantum. Spleen aspirates from six dogs previously diagnosed as infected by parasitological methods were simultaneously inoculated in each NNN-test medium, including the conventional medium prepared with rabbit blood (NNN-R), and the cultures were examined for three weeks under optic microscopy. Spleen samples were also analyzed for parasite loads by quantitative PCR (qPCR). Cultures from three of the six dogs (50%) were positive in at least one of the NNN-test media: one sample presented the highest spleen parasite load by qPCR (1.19 × 10 4 parasites/mL) and was positive in all test media; the second sample presented parasitic isolation in the first week of culture in all inoculated media, of which the NNN-C medium had the highest mean parasite count (NNN-C = 23.5 × 10 4 /mL vs. NNN-R = 3.25 × 10 4 /mL); the third sample was positive only in the NNN-S medium besides the conventional control NNN-R. Cultures from the three remaining dogs were negative in all NNN media, including the control and test media; of those three dogs, two presented the lowest spleen parasitic loads according to qPCR. Blood from chicken, ox, horse and sheep shown to be viable for the preparation of NNN culture medium for the primary isolation of L. infantum from samples of naturally infected dogs and can be considered as an alternative to rabbit blood when necessary. Copyright © 2018 Elsevier B.V. All rights reserved.
Kim, J H; Park, H G; Kim, J H; Jung, H; Kim, J K; Oh, S S; Shin, D H; Lim, E J; Kim, Y J
2008-05-01
The goal of this study was to develop a novel cooking method for fried meat products, to improve their nutritional value, and to provide superior taste and texture. We used the fat derived from each individual meat source during radiant heat roasting (alternate roasting with its own fat: AROF) without deep-fat frying (DFF), first without any air flow and subsequently with an exposure to air flow. We then compared these roasted chicken samples to breaded fried chicken samples that were deep-fat fried in 3 types of fat: soybean oil (SB), partially hydrogenated soybean oil (PSB), and lard. The final fat contents of both the skin and lean parts of the AROF samples of chicken were less than half of those of the DFF groups. The total trans-fatty acids (TFA) contents were significantly lower in the AROF samples compared to the DFF samples. The cholesterol levels of the samples did not show any significant differences among the tested groups, except for the sample fried in lard, which was significantly higher. Moreover, the sensory evaluation results showed that the crispy texture of the AROF samples was not significantly different from that of the DFF samples (P < 0.05); the AROF samples had higher scores for the characteristic fried flavor and for overall acceptability (P < 0.05). This study shows the potential value of products prepared by AROF, which can successfully replace DFF methods used for chicken and other meat products and improve their nutritional value.
Odegård, M; Mansfeld, J; Dundas, S H
2001-08-01
Calibration materials for microanalysis of Ti minerals have been prepared by direct fusion of synthetic and natural materials by resistance heating in high-purity graphite electrodes. Synthetic materials were FeTiO3 and TiO2 reagents doped with minor and trace elements; CRMs for ilmenite, rutile, and a Ti-rich magnetite were used as natural materials. Problems occurred during fusion of Fe2O3-rich materials, because at atmospheric pressure Fe2O3 decomposes into Fe3O4 and O2 at 1462 degrees C. An alternative fusion technique under pressure was tested, but the resulting materials were characterized by extensive segregation and development of separate phases. Fe2O3-rich materials were therefore fused below this temperature, resulting in a form of sintering, without conversion of the materials into amorphous glasses. The fused materials were studied by optical microscopy and EPMA, and tested as calibration materials by inductively coupled plasma mass spectrometry, equipped with laser ablation for sample introduction (LA-ICP-MS). It was demonstrated that calibration curves based on materials of rutile composition, within normal analytical uncertainty, generally coincide with calibration curves based on materials of ilmenite composition. It is, therefore, concluded that LA-ICP-MS analysis of Ti minerals can with advantage be based exclusively on calibration materials prepared for rutile, thereby avoiding the special fusion problems related to oxide mixtures of ilmenite composition. It is documented that sintered materials were in good overall agreement with homogeneous glass materials, an observation that indicates that in other situations also sintered mineral concentrates might be a useful alternative for instrument calibration, e.g. as alternative to pressed powders.
School Administration: Persistent Dilemmas in Preparation and Practice.
ERIC Educational Resources Information Center
Jacobson Stephen L., Ed.; Hickcox, Edward S., Ed.; Stevenson, Robert B., Ed.
Much of administrative preparation and practice centers on problem solving, developing alternative solutions, and selecting among competing alternatives for the most feasible solutions. Some of the persistent dilemmas resident in the training and the functioning of administrators are examined here by scholars and practitioners of educational…
Moisture sorption curves of fruit and nut cereal bar prepared with sugar and sugar substitutes.
Pallavi, Byrappa Vasu; Chetana, Ramakrishna; Ravi, Ramaswamy; Reddy, Sunkireddy Yella
2015-03-01
Low sugar, low fat, dry fruit and nut cereal bars without sugar were prepared using cereals, nuts, and sugar substitutes. The sorption characteristics of the bars prepared with sugar substitutes in comparison with that of sugar were studied by keeping the bars at water activity (aw) from 0.1 to 0.9. The sorption isotherms of low sugar bars were practically identical below aw of 0.5 but above aw of 0.5, a clear differentiation in the isotherms could be observed compared to that of sugar counterpart. A sharp increase in moisture content was observed in the bars prepared with alternative sweeteners, above aw 0.6, whereas a gradual increase in aw was observed in the case of bar prepared with sugar. The ERH (Equilibrium relative humidity) value for bar with sugar was 50 %, and for bars prepared with alternative sweeteners, it was about 60 %. Low sugar cereal bar prepared with sorbitol + maltitol (SM) syrup scored higher sensory quality compared to other product prepared with sorbitol + nutriose (SN) as the former retained softness and chewiness on storage. Thus, it was observed that bars with alternative sweeteners will be more stable as their ERH is closer to normal ambient conditions compared to that prepared with sugar.
Anumula, Lavanya; Kumar, Kv Suneel; Krishna, Chnv Murali; Lakshmi, K Sree
2017-07-01
Dental caries is one of the most common causes of morbidity of the tooth. Attempts have been made to reduce the pathogen population size i.e., Mutans Streptococci (MS) to demote the incidence of caries and increase the resistance of the tooth to cariogenic attack. To evaluate the antibacterial efficacy of freshly prepared ozonated water, in proposing it as an alternative mouth rinse on MS in comparison to Chlorhexidine (CHX). Subjects with high caries incidence and MS counts more than 105 Colony Forming Unit (CFU) were selected and divided by block randomization into two groups of 23 subjects each. The subjects were advised to use the respective mouth rinses under the operator surveillance, consecutively for 14 days. Stimulated salivary samples were collected from the subjects on the first day, 7 th and 14 th day to analyse the changes in MS counts during the course of use of oral rinses. The obtained data was tabulated and statistically analysed. Freshly prepared ozonated water showed a statistically significant reduction in MS counts after an interval of 7 days and 14 days when compared to CHX. Ozonated water when consecutively used as a mouth rinse resulted in a significant reduction of MS counts. Hence, it can be used as an alternative to chlorhexidine.
COMPENDIUM OF METHODS FOR THE DETERMINATION ...
This Second Edition of the Compendium has been prepared to provide regional, state and local environmental regulatory agencies with step-by-step sampling and analysis procedures for the determination of selected toxic organic pollutants in ambient air. It is designed to assist those persons responsible for sampling and analysis of toxic organic pollutants in complying with the requirements of Title III of the Clean Air Act. This revised Compendium presents a set of 17 methods in a standardized format with a variety of applicable sampling methods, as well as several analytical techniques, for specific classes of organic pollutants, as appropriate to the specific pollutant compound, its level, and potential interferences. Consequently, this treatment allows the user flexibility in selecting alternatives to complement his or her background and laboratory capability. Information
Xi, Yanwei; Arbabi, Aryan; McNaughton, Amy J M; Hamilton, Alison; Hull, Danna; Perras, Helene; Chiu, Tillie; Morrison, Shawna; Goldsmith, Claire; Creede, Emilie; Anger, Gregory J; Honeywell, Christina; Cloutier, Mireille; Macchio, Natasha; Kiss, Courtney; Liu, Xudong; Crocker, Susan; Davies, Gregory A; Brudno, Michael; Armour, Christine M
2017-01-01
To develop an alternate noninvasive prenatal testing method for the assessment of trisomy 21 (T21) using a targeted semiconductor sequencing approach. A customized AmpliSeq panel was designed with 1,067 primer pairs targeting specific regions on chromosomes 21, 18, 13, and others. A total of 235 samples, including 30 affected with T21, were sequenced with an Ion Torrent Proton sequencer, and a method was developed for assessing the probability of fetal aneuploidy via derivation of a risk score. Application of the derived risk score yields a bimodal distribution, with the affected samples clustering near 1.0 and the unaffected near 0. For a risk score cutoff of 0.345, above which all would be considered at "high risk," all 30 T21-positive pregnancies were correctly predicted to be affected, and 199 of the 205 non-T21 samples were correctly predicted. The average hands-on time spent on library preparation and sequencing was 19 h in total, and the average number of reads of sequence obtained was 3.75 million per sample. With the described targeted sequencing approach on the semiconductor platform using a custom-designed library and a probabilistic statistical approach, we have demonstrated the feasibility of an alternate method of assessment for fetal T21. © 2017 S. Karger AG, Basel.
Vannah, Courtney E; McComas, Martha; Taverna, Melanie; Hicks, Beatriz; Wright, Rebecca
2014-12-01
The purpose of this study was to determine the perceived level of preparedness Maine Independent Practice Dental Hygienists (IPDHs) received from their standard undergraduate dental hygiene education, and recognize areas necessary for further preparation in order to explore careers beyond the private practice dental model. A convenience sample of 6 IPDHs participated in a survey exploring their educational experience in public health and alternative practice settings. The survey also asked for their recommendations to advance dental hygiene education to meet the needs of those wishing to pursue alternative practice careers. This study found that participants felt underprepared by their dental hygiene education with deficits in exposure to public health, business skills necessary for independent practice, communication training and understanding of situations which require referral for treatment beyond the IPDH scope of practice. As the dental hygiene profession evolves, dental hygiene education must as well. The IPDH participants' recommendations for dental hygiene programs include increased exposure to alternative settings and underserved populations as well as elective courses for those students interested in alternative practice and business ownership. Copyright © 2014 The American Dental Hygienists’ Association.
NASA Astrophysics Data System (ADS)
Abu-Surrah, Adnan S.; Abdul Jawad, Saadi; Al-Ramahi, Esraa; Hallak, Awni B.; Khattari, Z.
2015-04-01
New alternating poly(propylene-alt-carbon monoxide/ethylene-alt-carbon monoxide) (PECO)/multiwalled carbon nanotubes (MWCNTs) composites have been prepared. Dielectric permittivity, electric modulus and ac conductivity of the isolated materials were investigated as a function of fiber aspect ratio, frequency and temperature. For aspect ratio of 30 and 200, a transition from insulator to semiconductor was observed at frequency 1×104. However, for high aspect ratio sample (660), no transition was observed and the conductivity is frequency independent in the measured frequency range of 10-106 Hz. The conductivity increases from about 1×10-4 for the sample that contain fibers of aspect ratio 30 and reaches 5×10-2 (Ω m)-1 for aspect ratio was 660. This behavior can be modeled by a circuit that consists of a contact resistance in series with a parallel combination of resistance (R) and capacitance (C). The calculated activation energy for sample filled with fibers having aspect ratio 30 is about 0.26 eV and decreases to about 0.16 eV when the aspect ratio is 660.
Stojićević, Ivana; Dimitrijević, Ljiljana; Dovezenski, Nebojša; Živković, Irena; Petrušić, Vladimir; Marinković, Emilija; Inić-Kanada, Aleksandra; Stojanović, Marijana
2011-08-01
Given an existing demand to establish a process of tetanus vaccine production in a way that allows its complete validation and standardization, this paper focuses on tetanus toxoid purification step. More precisely, we were looking at a possibility to replace the widely used ammonium-sulphate precipitation by a chromatographic method. Based on the tetanus toxin's biochemical characteristics, we have decided to examine the possibility of tetanus toxoid purification by hydrophobic chromatography, and by chromatographic techniques based on interaction with immobilized metal ions, i.e. chelating chromatography and immobilized metal affinity chromatography. We used samples obtained from differently fragmented crude tetanus toxins by formaldehyde treatment (assigned as TTd-A and TTd-B) as starting material for tetanus toxoid purification. Obtained results imply that purification of tetanus toxoid by hydrophobic chromatography represents a good alternative to ammonium-sulphate precipitation. Tetanus toxoid preparations obtained by hydrophobic chromatography were similar to those obtained by ammonium-sulphate precipitation in respect to yield, purity and immunogenicity. In addition, their immunogenicity was similar to standard tetanus toxoid preparation (NIBSC, Potters Bar, UK). Furthermore, the characteristics of crude tetanus toxin preparations had the lowest impact on the final purification product when hydrophobic chromatography was the applied method of tetanus toxoid purification. On the other hand, purifications of tetanus toxoid by chelating chromatography or immobilized metal affinity chromatography generally resulted in a very low yield due to not satisfactory tetanus toxoid binding to the column, and immunogenicity of the obtained tetanus toxoid-containing preparations was poor. Copyright © 2011 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-10
... DEPARTMENT OF DEFENSE Department of the Army; Corps of Engineers Intent To Prepare an Environmental Impact Statement for Northwest Aggregates' Previously Authorized Replacement of an Existing Barge... alternatives, and the depth to which the various alternatives will be evaluated in the EIS. The Corps has...
Mozaner Bordin, Dayanne C; Alves, Marcela N R; Cabrices, Oscar G; de Campos, Eduardo G; De Martinis, Bruno Spinosa
2014-01-01
Drug abuse by pregnant women is considered a serious public health problem worldwide. Meconium is the first excretion in newborns and has been used as an alternative matrix to evaluate in utero drug exposure. Solid phase extraction (SPE) is widely employed to prepare and clean up samples in the field of forensic analysis. Most SPE products require large volumes of solvent, which culminates in longer sample processing times and increased cost per sample. Disposable pipette extraction (DPX) tips have been used as an alternative to traditional SPE cartridges. They combine efficient and rapid extraction with reduced solvent consumption. The purpose of this study was to develop and validate a method to determine nicotine, cotinine, cocaine, benzoylecgonine, cocaethylene and methyl ester anhydroecgonine in meconium using DPX and gas chromatography-mass spectrometry (GC-MS). Validation results indicated that extraction efficiency ranged 50-98%, accuracy 92-106%, intra-assay precision 4-12% and inter-assay precision 6-12%. Linear calibration curves resulted in R(2) values >0.99, limits of detection ranged from 2.5 to 15 ng/g and the limit of quantitation from 10 to 20 ng/g. The DPX-GC-MS method was shown to selectively analyze trace concentrations of drugs in meconium samples. Finally, the developed and validated method was applied to 50 meconium samples.
Kashiwagi, Tom; Maxwell, Elisabeth A; Marshall, Andrea D; Christensen, Ana B
2015-01-01
Sharks and rays are increasingly being identified as high-risk species for extinction, prompting urgent assessments of their local or regional populations. Advanced genetic analyses can contribute relevant information on effective population size and connectivity among populations although acquiring sufficient regional sample sizes can be challenging. DNA is typically amplified from tissue samples which are collected by hand spears with modified biopsy punch tips. This technique is not always popular due mainly to a perception that invasive sampling might harm the rays, change their behaviour, or have a negative impact on tourism. To explore alternative methods, we evaluated the yields and PCR success of DNA template prepared from the manta ray mucus collected underwater and captured and stored on a Whatman FTA™ Elute card. The pilot study demonstrated that mucus can be effectively collected underwater using toothbrush. DNA stored on cards was found to be reliable for PCR-based population genetics studies. We successfully amplified mtDNA ND5, nuclear DNA RAG1, and microsatellite loci for all samples and confirmed sequences and genotypes being those of target species. As the yields of DNA with the tested method were low, further improvements are desirable for assays that may require larger amounts of DNA, such as population genomic studies using emerging next-gen sequencing.
Maxwell, Elisabeth A.; Marshall, Andrea D.; Christensen, Ana B.
2015-01-01
Sharks and rays are increasingly being identified as high-risk species for extinction, prompting urgent assessments of their local or regional populations. Advanced genetic analyses can contribute relevant information on effective population size and connectivity among populations although acquiring sufficient regional sample sizes can be challenging. DNA is typically amplified from tissue samples which are collected by hand spears with modified biopsy punch tips. This technique is not always popular due mainly to a perception that invasive sampling might harm the rays, change their behaviour, or have a negative impact on tourism. To explore alternative methods, we evaluated the yields and PCR success of DNA template prepared from the manta ray mucus collected underwater and captured and stored on a Whatman FTA™ Elute card. The pilot study demonstrated that mucus can be effectively collected underwater using toothbrush. DNA stored on cards was found to be reliable for PCR-based population genetics studies. We successfully amplified mtDNA ND5, nuclear DNA RAG1, and microsatellite loci for all samples and confirmed sequences and genotypes being those of target species. As the yields of DNA with the tested method were low, further improvements are desirable for assays that may require larger amounts of DNA, such as population genomic studies using emerging next-gen sequencing. PMID:26413431
The implementation of liquid-based cytology for lung and pleural-based diseases.
Michael, Claire W; Bedrossian, Carlos C W M
2014-01-01
First introduced for the processing of cervico-vaginal samples, liquid-based cytology (LBC) soon found application in nongynecological specimens, including bronchoscopic brushings, washings and transcutaneous and transbronchial aspiration biopsy of the lung as well as pleural effusions. This article reviews the existing literature related to these specimens along with the authors' own experience. A literature review was conducted through Ovid MEDLINE and PubMed search engines using several key words. Most of the literature is based on data collected through the use of split samples. The data confirms that the use of LBC is an acceptable, and sometimes superior, alternative to the conventional preparations (CP). LBC offers several advantages, including the ability to transport in a stable collecting media, elimination of obscuring elements, ease of screening, excellent preservation, random representative sample, and application of ancillary techniques on additional preparations. Some diagnostic pitfalls related to the introduced artifacts were reported. The utilization of LBC offers many advantages over CP and has a diagnostic accuracy that is equal to or surpasses that of CP. LBC affords a bridge to the future application of molecular and other ancillary techniques to cytology. Knowledge of the morphological artifacts is useful at the early stages of implementation.
Preparation of metagenomic libraries from naturally occurring marine viruses.
Solonenko, Sergei A; Sullivan, Matthew B
2013-01-01
Microbes are now well recognized as major drivers of the biogeochemical cycling that fuels the Earth, and their viruses (phages) are known to be abundant and important in microbial mortality, horizontal gene transfer, and modulating microbial metabolic output. Investigation of environmental phages has been frustrated by an inability to culture the vast majority of naturally occurring diversity coupled with the lack of robust, quantitative, culture-independent methods for studying this uncultured majority. However, for double-stranded DNA phages, a quantitative viral metagenomic sample-to-sequence workflow now exists. Here, we review these advances with special emphasis on the technical details of preparing DNA sequencing libraries for metagenomic sequencing from environmentally relevant low-input DNA samples. Library preparation steps broadly involve manipulating the sample DNA by fragmentation, end repair and adaptor ligation, size fractionation, and amplification. One critical area of future research and development is parallel advances for alternate nucleic acid types such as single-stranded DNA and RNA viruses that are also abundant in nature. Combinations of recent advances in fragmentation (e.g., acoustic shearing and tagmentation), ligation reactions (adaptor-to-template ratio reference table availability), size fractionation (non-gel-sizing), and amplification (linear amplification for deep sequencing and linker amplification protocols) enhance our ability to generate quantitatively representative metagenomic datasets from low-input DNA samples. Such datasets are already providing new insights into the role of viruses in marine systems and will continue to do so as new environments are explored and synergies and paradigms emerge from large-scale comparative analyses. © 2013 Elsevier Inc. All rights reserved.
Rodríguez-Cea, Andrés; de la Campa, María Rosario Fernández; Sanz-Medel, Alfredo
2005-01-01
Cytochromes P-450 are members of a superfamily of hemoproteins involved in the oxidative metabolism of various physiological and xenobiotic compounds in eukaryotes and prokaryotes. The multiplicity of this group of enzymes has been widely studied by chromatographic techniques, mainly high-performance liquid chromatography (HPLC). Because these enzymes are membrane-bound proteins, sample preparation for chromatographic separation of P-450 enzymes requires a solubilization step. The sample-preparation procedures are critical, because detergents affect not only the efficiency of protein solubilization but also their further chromatographic resolution. Trout liver microsomes have been taken here as a model sample to investigate iron speciation in cytochrome P-450. Trouts were treated intraperitoneally with beta-naphthoflavone, a potent inducer of some P-450 enzymes, and a microsomal suspension containing 7.4+/-0.1 nmol mL(-1) P-450 enzymes was obtained by ultracentrifugation. Lubrol PX was selected as detergent for solubilization, resulting in about 90% solubilization recovery. The solubilized cytochromes P-450 were further separated by AE-FPLC, with UV detection, or coupled to ICP-MS with an octapole reaction system, ICP-(ORS)MS (monitoring Fe signals at masses 54, 56, and 57). A sampling procedure and chromatographic conditions are developed and were successfully applied to iron speciation in trout liver P-450 enzymes. ICP-(ORS)MS detection of P-450 enzymes is Fe-specific and so will give accurate information on the prosthetic group of the protein, which can constitute an advantageous alternative to classical methods for detection of these hemoproteins.
Zhao, Weiquan; Yang, Guang; Zhong, Fanyi; Yang, Nan; Zhao, Xin; Qi, Yunpeng; Fan, Guorong
2014-09-01
Silymarin extracted from Silybum marianum (L.) Gaertn consists of a large number of flavonolignans, of which diastereoisomeric flavonolignans including silybin A and silybin B, and isosilybin A and isosilybin B are the main bioactive components, whose preparation from the crude extracts is still a difficult task. In this work, binary-column recycling preparative high-performance liquid chromatography systems without sample loop trapping, where two columns were switched alternately via one or two six-port switching valves, were established and successfully applied to the isolation and purification of the four diastereoisomeric flavonolignans from silymarin. The proposed system showed significant advantages over conventional preparative high-performance liquid chromatography with a single column in increasing efficiency and reducing the cost. To obtain the same amounts of products, the proposed system spends only one tenth of the time that the conventional system spends, and needs only one eleventh of the solvent that the conventional system consumes. Using the proposed system, the four diastereoisomers were successfully isolated from silymarin with purities over 98%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Comparative study of chitosan and chitosan-gelatin scaffold for tissue engineering
NASA Astrophysics Data System (ADS)
Kumar, Pawan; Dehiya, Brijnandan S.; Sindhu, Anil
2017-12-01
A number of orthopedic disorders and bone defect issues are solved by scaffold-based therapy in tissue engineering. The biocompatibility of chitosan (polysaccharide) and its similarity with glycosaminoglycan makes it a bone-grafting material. The current work focus on the synthesis of chitosan and chitosan-gelatin scaffold for hard tissue engineering. The chitosan and chitosan-gelatin scaffold have shown improved specific surface area, density, porosity, mechanical properties, biodegradability and absorption. These scaffolds can lead to the development or artificial fabrication of hard tissue alternates. The porous scaffold samples were prepared by freeze-drying method. The microstructure, mechanical and degradable properties of chitosan and chitosan-gelatin scaffolds were analyzed and results revealed that the scaffolds prepared from chitosan-gelatin can be utilized as a useful matrix for tissue engineering.
Alternative Routes to Teacher Certification.
ERIC Educational Resources Information Center
Smith-Davis, Judy
This literature review examines alternative routes to teacher certification and presents alternative certification regulations and policies for 19 states. Three categories of nontraditional personnel preparation programs are noted: nontraditional recruitment programs, retraining programs, and alternative certification programs. A definition of…
ACCELERATED SOLVENT EXTRACTION COMBINED WITH ...
A research project was initiated to address a recurring problem of elevated detection limits above required risk-based concentrations for the determination of semivolatile organic compounds in high moisture content solid samples. This project was initiated, in cooperation with the EPA Region 1 Laboratory, under the Regional Methods Program administered through the ORD Office of Science Policy. The aim of the project was to develop an approach for the rapid removal of water in high moisture content solids (e.g., wetland sediments) in preparation for analysis via Method 8270. Alternative methods for water removal have been investigated to enhance compound solid concentrations and improve extraction efficiency, with the use of pressure filtration providing a high-throughput alternative for removal of the majority of free water in sediments and sludges. In order to eliminate problems with phase separation during extraction of solids using Accelerated Solvent Extraction, a variation of a water-isopropanol extraction method developed at the USGS National Water Quality Laboratory in Denver, CO is being employed. The concentrations of target compounds in water-isopropanol extraction fluids are subsequently analyzed using an automated Solid Phase Extraction (SPE)-GC/MS method developed in our laboratory. The coupled approaches for dewatering, extraction, and target compound identification-quantitation provide a useful alternative to enhance sample throughput for Me
Composition of Indigo naturalis.
Plitzko, Inken; Mohn, Tobias; Sedlacek, Natalie; Hamburger, Matthias
2009-06-01
A proposal for a European Pharmacopoeia monograph concerning Indigo naturalis has recently been published, whereby the indigo (1) and indirubin (2) content should be determined by HPLC-UV. This method was tested, but problems were seen with the dosage of indigo due to poor solubility. A quantitative assay for indigo based on (1)H-NMR was developed as an alternative. The HPLC and qNMR assays were compared with eight Indigo naturalis samples. The HPLC assay consistently gave much lower indigo concentrations because solubility was the limiting factor in sample preparation. In one sample, sucrose was identified by (1)H-NMR as an organic additive. Simple wet chemistry assays for undeclared additives such as sugars and starch were tested with artificially spiked Indigo naturalis samples to establish their limits of detection, and sulfate ash determinations were carried out in view of a better assessment of Indigo naturalis in a future European monograph.
Toxic metals in ayurvedic preparations from a public health lead poisoning cluster investigation.
Mikulski, Marek A; Wichman, Michael D; Simmons, Donald L; Pham, Anthony N; Clottey, Valentina; Fuortes, Laurence J
2017-07-01
Background Herbal formulations, traditional medicine, and complementary and alternative medicine are used by the majority of the world's population. Toxicity associated with use of Ayurvedic products due to metal content is an increasingly recognized potential public health problem. Objectives Report on toxic metals content of Ayurvedic products obtained during an investigation of lead poisoning among users of Ayurvedic medicine. Methods Samples of Ayurvedic formulations were analyzed for metals and metalloids following established US. Environmental Protection Agency methods. Results Lead was found in 65% of 252 Ayurvedic medicine samples with mercury and arsenic found in 38 and 32% of samples, respectively. Almost half of samples containing mercury, 36% of samples containing lead and 39% of samples containing arsenic had concentrations of those metals per pill that exceeded, up to several thousand times, the recommended daily intake values for pharmaceutical impurities. Conclusions Lack of regulations regarding manufacturing and content or purity of Ayurvedic and other herbal formulations poses a significant global public health problem.
ERIC Educational Resources Information Center
Gagliardi, Karen M.
2012-01-01
In this mixed-method causal comparative and interview-based study, I developed an understanding of the way in which school principals perceived their level of preparedness. The effectiveness of two types of leadership preparation programs, traditional-university based and alternative, were considered on principal preparedness. One hundred and…
Connecting University Course Work and Practitioner Knowledge through Mediated Field Experiences
ERIC Educational Resources Information Center
Campbell, Sara Sunshine; Dunleavy, Teresa K.
2016-01-01
Teacher preparation in the United States, both university based and alternative, has been strongly critiqued as ineffective when it comes to preparing new teachers. Although many criticisms have been directed at alternative teacher education, this article focuses on university-based teacher education because approximately 70% of our nation's…
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2007-01-01
Headquarters National Aeronautics and Space Administration (NASA) chartered the NASA Acquisition Pollution Prevention (AP2) Office to coordinate agency activities affecting pollution prevention issues identified during system and component acquisition and sustainment processes. The primary objectives of the AP2 Office are to: (1) Reduce or eliminate the use of hazardous materials or hazardous processes at manufacturing, remanufacturing, and sustainment locations. (2) Avoid duplication of effort in actions required to reduce or eliminate hazardous materials through joint center cooperation and technology sharing. The objective of this project was to qualify candidate alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel applications at NASA facilities. This project compares the surface preparation/depainting performance of the proposed alternatives to existing surface preparation/depainting systems or standards. This Joint Test Report (JTR) contains the results of testing as per the outlines of the Joint Test Protocol (JTP), Joint Test Protocol for Validation of Alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel, and the Field Test Plan (FTP), Field Evaluations Test Plan for Validation of Alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel, for critical requirements and tests necessary to qualify alternatives for coating removal systems. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of government and industry participants. This JTR documents the results of the testing as well as any test modifications made during the execution of the project. This JTR is made available as a reference for future pollution prevention endeavors by other NASA Centers, the Department of Defense and commercial users to minimize duplication of effort. The current coating removal processes identified herein are for polyurethane, epoxy and other paint systems applied by conventional wet-spray processes. A table summarizes the target hazardous materials, processes and materials, applications, affected programs, and candidate substrates.
Pietrzak-Johnston, S M; Bishop, H; Wahlquist, S; Moura, H; Da Silva, N D; Da Silva, S P; Nguyen-Dinh, P
2000-05-01
Formalin and mercuric chloride-based low-viscosity polyvinyl alcohol (LV-PVA) are widely used by most diagnostic parasitology laboratories for preservation of helminth eggs and protozoan cysts and trophozoites in fecal specimens. Concerns about the toxicity of formalin and the difficulty of disposal of LV-PVA are powerful incentives to use alternate preservatives. Such alternatives have been marketed by several companies and are often presented as one-vial, non-mercuric chloride fixatives that aim at performing the same role as formalin and PVA combined. We compared five, one-vial commercial preservatives, two from Meridian Diagnostics, Inc. (Ecofix and sodium acetate-acetic acid-formalin), and one each from Scientific Device Laboratories, Inc. (Parasafe), Alpha Tec Systems, Inc. (Proto-fix), and Streck Laboratories, Inc. (STF), with 10% formalin and LV-PVA. Fecal specimens obtained from patients in a Brazilian hospital were aliquoted within 12 h of collection into the seven preservatives mentioned above and were processed after 1 month at the Centers for Disease Control and Prevention. Direct and concentrated permanent smears as well as concentrates for 20 positive specimens (a total of 259 processed samples) were prepared, stained according to the manufacturers' instructions, examined, and graded. Positive specimens contained one or more parasites with stages consisting of eggs, larvae, cysts, and a few trophozoites of Giardia intestinalis. Criteria for assessment of the preservatives included the quality of the diagnostic characteristics of helminth eggs, protozoan cysts, and trophozoites, ease of use, and cost. Acceptable alternatives to formalin for wet preparations were found. Ecofix was found to be comparable to the traditional "gold standard" LV-PVA for the visualization of protozoa in permanent stained smears. This study suggests that more acceptable alternatives to the traditional formalin and LV-PVA exist.
Haenssgen, Marco J
2015-01-01
The increasing availability of online maps, satellite imagery, and digital technology can ease common constraints of survey sampling in low- and middle-income countries. However, existing approaches require specialised software and user skills, professional GPS equipment, and/or commercial data sources; they tend to neglect spatial sampling considerations when using satellite maps; and they continue to face implementation challenges analogous to conventional survey implementation methods. This paper presents an alternative way of utilising satellite maps and digital aides that aims to address these challenges. The case studies of two rural household surveys in Rajasthan (India) and Gansu (China) compare conventional survey sampling and implementation techniques with the use of online map services such as Google, Bing, and HERE maps. Modern yet basic digital technology can be integrated into the processes of preparing, implementing, and monitoring a rural household survey. Satellite-aided systematic random sampling enhanced the spatial representativeness of the village samples and entailed savings of approximately £4000 compared to conventional household listing, while reducing the duration of the main survey by at least 25 %. This low-cost/low-tech satellite-aided survey sampling approach can be useful for student researchers and resource-constrained research projects operating in low- and middle-income contexts with high survey implementation costs. While achieving transparent and efficient survey implementation at low costs, researchers aiming to adopt a similar process should be aware of the locational, technical, and logistical requirements as well as the methodological challenges of this strategy.
Aptasensors for quantitative detection of Salmonella Typhimurium.
Ansari, Najmeh; Yazdian-Robati, Rezvan; Shahdordizadeh, Mahin; Wang, Zhouping; Ghazvini, Kiarash
2017-09-15
Salmonella is one of the most frequent causes of food borne infectious disease. Among nearly 2500 documented serotypes are reported, Salmonella Typhimurium is the number one serotype associated with salmonellosis worldwide. Many different methods have been developed for the detection and quantification of S. typhimurium. Most of these assays are usually expensive, time consuming and require difficult sample preparation steps. Therefore, it is necessary to develop rapid, robust, cost-effective and sensitive alternative detection methods. In the last years, aptasensors, used for detection of S. typhimurium in different samples. In this review, recent advances and applications of aptasensors for the detection and quantification of S. typhimurium in details have been summarized. Copyright © 2017 Elsevier Inc. All rights reserved.
Lee, Jungmin; Steenwerth, Kerri L
2011-08-01
This is a study on the influence that two rootstocks (110R, high vigour; 420A, low vigour) and three vineyard floor management regimes (tilled resident vegetation - usual practise in California, and barley cover crops that were either mowed or tilled) had upon grape nitrogen-containing compounds (mainly ammonia and free amino acids recalculated as YAN), sugars, and organic acids in 'Cabernet Sauvignon' clone 8. A significant difference was observed for some of the free amino acids between rootstocks. In both sample preparation methods (juiced or chemically extracted), 110R rootstock grapes were significantly higher in SER, GLN, THR, ARG, VAL, ILE, LEU, and YAN than were 420A rootstock grapes. Differences in individual free amino acid profiles and concentrations were observed between the two sample preparations, which indicate that care should be taken when comparing values from dissimilar methods. No significant differences among vineyard floor treatments were detected, which suggests that mowing offers vineyard managers a sustainable practise, alternative to tilling, without negatively affecting grape nitrogen compounds, sugars, or organic acids. Published by Elsevier Ltd.
Silver Nanoforms as a Therapeutic Agent for Killing Escherichia coli and Certain ESKAPE Pathogens.
Kedziora, A; Korzekwa, K; Strek, W; Pawlak, A; Doroszkiewicz, W; Bugla-Ploskonska, G
2016-07-01
The scope of this study included the preparation of silver nanoforms with high antimicrobial efficacy, low cost, and ease of application. The term 'silver nanoforms' refers to silver located on the amorphous or crystalline titanium dioxide (TiO2). Silver nanoforms may be used as an alternative to antibiotics in killing bacteria. Pure and silver-incorporated titanium (used as a carrier) was prepared using the sol-gel-modified method. Physical and chemical properties of the samples were described, and the antibacterial activity was indicated using the following strains of bacteria: Staphylococcus aureus, Klebsiella pneumoniae (ESKAPE pathogens), and Escherichia coli. The results have shown that the antibacterial activity of silver nanoforms with amorphous TiO2 is much better than that in the samples based on anatase (crystalline TiO2). The sensitivity of the tested bacteria to silver nanoforms depends on physical and chemical properties of the nanoforms and individual characteristics of the bacteria. For the first time, significant participation of amorphous TiO2 in antibacterial compounds has been described through this study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-08
Laboratory applications for the analysis of PCBS (polychlorinated biphenyls) in environmental matrices such as soil/sediment/sludge and oil/waste oil were evaluated for potential reduction in waste, source reduction, and alternative techniques for final determination. As a consequence, new procedures were studied for solvent substitution, miniaturization of extraction and cleanups, minimization of reagent consumption, reduction of cost per analysis, and reduction of time. These new procedures provide adequate data that meet all the performance requirements for the determination of PCBS. Use of the new procedures reduced costs for all sample preparation techniques. Time and cost were also reduced by combining the newmore » sample preparation procedures with the power of fast gas chromatography. Separation of Aroclor 1254 was achieved in less than 6 min by using DB-1 and SPB-608 columns. With the greatly shortened run times, reproducibility can be tested quickly and consequently with low cost. With performance-based methodology, the applications presented here can be applied now, without waiting for regulatory approval.« less
Analysis of RNA structure using small-angle X-ray scattering
Cantara, William A.; Olson, Erik D.; Musier-Forsyth, Karin
2016-01-01
In addition to their role in correctly attaching specific amino acids to cognate tRNAs, aminoacyl-tRNA synthetases (aaRS) have been found to possess many alternative functions and often bind to and act on other nucleic acids. In contrast to the well-defined 3D structure of tRNA, the structures of many of the other RNAs recognized by aaRSs have not been solved. Despite advances in the use of X-ray crystallography (XRC), nuclear magnetic resonance (NMR) spectroscopy and cryo-electron microscopy (cryo-EM) for structural characterization of biomolecules, significant challenges to solving RNA structures still exist. Recently, small-angle X-ray scattering (SAXS) has been increasingly employed to characterize the 3D structures of RNAs and RNA-protein complexes. SAXS is capable of providing low-resolution tertiary structure information under physiological conditions and with less intensive sample preparation and data analysis requirements than XRC, NMR and cryo-EM. In this article, we describe best practices involved in the process of RNA and RNA-protein sample preparation, SAXS data collection, data analysis, and structural model building. PMID:27777026
Rotary target method to prepare thin films of CdS/SiO 2 by pulsed laser deposition
NASA Astrophysics Data System (ADS)
Wang, H.; Zhu, Y.; Ong, P. P.
2000-12-01
Thin films of CdS-doped SiO 2 glass were prepared by using the conventional pulsed laser deposition (PLD) technique. The laser target consisted of a specially constructed rotary wheel which provided easy control of the exposure-area ratio to expose alternately the two materials to the laser beam. The physical target assembly avoided the potential complications inherent in chemically mixed targets such as in the sol-gel method. Time-of-flight (TOF) spectra confirmed the existence of the SiO 2 and CdS components in the thin-film samples so produced. X-ray diffraction (XRD) and atomic force microscopy(AFM) results showed the different sizes and structures of the as-deposited and annealed films. The wurtzite phase of CdS was found in the 600 oC-annealed sample, while the as-deposited film showed a cubic-hexagonal mixed structure. In the corresponding PL (photoluminescence) spectra, a red shift of the CdS band edge emission was found, which may be a result of the interaction between the CdS nanocrystallite and SiO 2 at their interface.
Strontium hexaferrite (SrFe12O19) based composites for hyperthermia applications
NASA Astrophysics Data System (ADS)
Rashid, Amin Ur; Southern, Paul; Darr, Jawwad A.; Awan, Saifullah; Manzoor, Sadia
2013-10-01
Mixed phase composites of SrFe12O19/MgFe2O4/ZrO2 were prepared via the citrate gel technique as potential candidate materials for magnetic hyperthermia. Structural and magnetic properties of the samples were studied using powder X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) and a vibrating sample magnetometer. XRD and FE-SEM data confirm that magnesium ferrite and zirconium oxide phases increased with increasing Mg and Zr content in the precursors. Magnetization loops for the composites were measured at room temperature and showed significant variation of saturation magnetization, coercivity and remanence depending on the amount of the highly anisotropic Sr-hexaferrite phase. The sample with the highest Mg and Zr content had the lowest coercivity (80 Oe) and saturation magnetization (41 emu/g). The composite samples each were exposed to a 214 kHz alternating magnetic field of amplitude 22 Oe and a significant heating effect was observed in selected samples, which suggests potential for use in magnetic hyperthermia.
NASA Astrophysics Data System (ADS)
Kaygili, Omer; Ates, Tankut; Keser, Serhat; Al-Ghamdi, Ahmed A.; Yakuphanoglu, Fahrettin
2014-08-01
The hydroxyapatite (HAp) samples in the presence of various amounts of ethylenediamine tetraacetic acid (EDTA) were prepared by sol-gel method. The effects of EDTA on the crystallinity, phase structure, chemical, micro-structural and dielectric properties of HAp samples were investigated. With the addition of EDTA, the average crystallite size of the HAp samples is gradually decreased from 30 to 22 nm and the crystallinity is in the range of 65-71%. The values of the lattice parameters (a and c) and volume of the unit cell are decreased by stages with the addition of EDTA. The dielectric parameters such as relative permittivity, dielectric loss and relaxation time are affected by the adding of EDTA. The alternating current conductivity of the as-synthesized hydroxyapatites increases with the increasing frequency and obeys the universal power law behavior. The HAp samples exhibit a non-Debye relaxation mechanism. The obtained results that the dielectrical parameters of the HAp sample can be controlled by EDTA.
Gari, Akawak; Yarlagadda, Raghavendra; Wolde-Mariam, Messay
2015-01-01
Background: Traditional medicine (TM) has maintained its popularity in all regions of the developing world. Even though, the wide acceptance of TM is a well-established fact, its status in a population with access to modern health is not well clear in the whole country. This study was carried out to assess the knowledge, attitudes, practice and management of TM among the community of Burka Jato Kebele, West Ethiopia. Methodology: A descriptive cross-sectional study was conducted on a total of 282 sampled individuals’ selected using systematic random sampling from January 28, 2013 to February 8, 2013 in Burka Jato Kebele, Nekemte town, East Wollega Zone, West of Ethiopia. Results: The majority (94.22%) of people in the study area relied on TM. Most of them were aware of medicinal herbs (55.7%). About half (40.79%) of the respondents were aware of the major side-effects of TM such as diarrhea (36.64%). About 31.85% of them prefer traditional medical practices (TMP) because they are cheap. Most (50%) of the species were harvested for their leaves to prepare remedies, followed by seed (21.15%) and root (13.46%) and the methods of preparation were pounding (27.54%), crushing (18.84%), a concoction (15.95%) and squeezing (13.04%). About 53.84% of them were used as fresh preparations. Remedies were reported to be administered through oral (53.85%), dermal or topical (36.54%), buccal (3.85%) and anal (5.77%). Conclusion: The study revealed that the use of TMs were quite popular among the population and a large proportion of the respondents not only preferred, but also used TMs notwithstanding that they lived in the urban communities with better access to modern medical care and medical practitioners. To use TM as a valuable alternative to conventional western medicine, further investigation must be undertaken to determine the validity, efficacy of the plants to make it available as an alternative medicine to human beings. PMID:25883518
Cheese is a reliable alternative meal for solid-phase gastric emptying study.
Drubach, Laura A; Kourmouzi, Vasiliki; Fahey, Frederic H
2010-05-01
We evaluated the labeling stability of several alternative meals that could be used to perform solid-phase gastric emptying study. Cooked egg whites labeled with technetium-99m sulfur colloid served as a control. Packaged instant oatmeal and instant mashed potatoes were prepared by adding hot water. Cheddar cheese was melted. Peanut butter was added to bread. The different meals were mixed with technetium-99m sulfur colloid (2.2-3.7 MBq), chopped into small pieces and placed in a glass tube containing gastric juice. Four samples of each meal were analyzed after 1 and 4 h of agitation with a 3-D rotator (two samples per time point). The meal samples were washed with 2 ml of saline and filtered using a blood transfusion filter. The activity in each sample before and after filtering was assayed in a dose calibrator. The percentage of initial radioactivity remaining with the meal of admixture with gastric juice was measured and the average of the two samples was taken. The percentage of activity bound to the solid phase was 98.2+/-1.9, 95.6+/-1.1, 62.1+/-1.7, 41.8+/-0.6, and 74.5+/-3.8% at 1 h and 98.5+/-1.0, 95.8+/-2.6, 77.2+/-6.8, 55.5+/-3.4 and 40.2+/-22.1 at 4 h for egg whites, cheese, oatmeal, mashed potatoes and peanut butter respectively. For egg whites and cheese, there was no significant difference between the values at 1 and 4 h (P>0.8). Cheddar cheese provides an alternative meal for assessing solid gastric emptying in children comparable to egg whites. Oatmeal and mashed potatoes had low and variable labeling stability and are not recommended. In view of the significant proportion of pediatric patients who refuse to eat scrambled eggs or have allergy to eggs, the availability of other meal choices is essential. The versatility of cheddar cheese, which can be added to macaroni or as a topping on pizza, makes it a useful alternative to labeled eggs.
Alternative Fuels Data Center: San Diego Prepares for Electric Vehicles in
Fleet Uses a Wide Variety of Alternative Fuels Dec. 5, 2015 Photo of a Coca-Cola alternative-fuel truck Alternative Fuel Vehicles July 15, 2015 Photo of a bus. Maryland County Fleet Uses Wide Variety of Alternative vehicle Mammoth Cave National Park Uses Only Alternative Fuel Vehicles Dec. 1, 2012 Frito-Lay Delivers
Godoy-Caballero, María del Pilar; Culzoni, María Julia; Galeano-Díaz, Teresa; Acedo-Valenzuela, María Isabel
2013-02-06
This paper presents the development of a non-aqueous capillary electrophoresis method coupled to UV detection combined with multivariate curve resolution-alternating least-squares (MCR-ALS) to carry out the resolution and quantitation of a mixture of six phenolic acids in virgin olive oil samples. p-Coumaric, caffeic, ferulic, 3,4-dihydroxyphenylacetic, vanillic and 4-hydroxyphenilacetic acids have been the analytes under study. All of them present different absorption spectra and overlapped time profiles with the olive oil matrix interferences and between them. The modeling strategy involves the building of a single MCR-ALS model composed of matrices augmented in the temporal mode, namely spectra remain invariant while time profiles may change from sample to sample. So MCR-ALS was used to cope with the coeluting interferences, on accounting the second order advantage inherent to this algorithm which, in addition, is able to handle data sets deviating from trilinearity, like the data herein analyzed. The method was firstly applied to resolve standard mixtures of the analytes randomly prepared in 1-propanol and, secondly, in real virgin olive oil samples, getting recovery values near to 100% in all cases. The importance and novelty of this methodology relies on the combination of non-aqueous capillary electrophoresis second-order data and MCR-ALS algorithm which allows performing the resolution of these compounds simplifying the previous sample pretreatment stages. Copyright © 2012 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-18
..., GSA, as the operational Joint Lead Agency, announces its Notice of Intent (NOI) to prepare an EIS for... York. The US Department of Homeland Security (DHS) will act as a Joint Lead Agency in ongoing...-Action Alternative''). The Action Alternative will be further refined into a series of reasonably...
Ryu, Young-Joon; Kim, Hankyeom; Jang, Sejin; Koo, Young-Mo
2013-06-01
Efficient management of human tissue samples is a critical issue; the supply of samples is unable to satisfy the current demands for research. Lack of informed consent is also an ethical problem. One of the goals of the 2012 revision of Korea's Bioethics and Safety Act was to implement regulations that govern the management of human tissue samples. To remain competitive, medical institutions must prepare for these future changes. In this report, we review two tissue management models that are currently in use; model 1 is the most common system utilized by hospitals in Korea and model 2 is implemented by some of the larger institutions. We also propose three alternative models that offer advantages over the systems currently in use. Model 3 is a multi-bank model that protects the independence of physicians and pathologists. Model 4 utilizes a comprehensive single bioresource bank; although in this case, the pathologists gain control of the samples, which may make it difficult to implement. Model 5, which employs a bioresource utilization steering committee (BUSC), is viable to implement and still maintains the advantages of Model 4. To comply with the upcoming law, we suggest that physicians and pathologists in an institution should collaborate to choose one of the improved models of tissue management system that best fits for their situation.
Ku, Bon Ki; Deye, Gregory J.; Turkevich, Leonid A.
2015-01-01
Fiber dimension (especially length) and biopersistence are thought to be important variables in determining the pathogenicity of asbestos and other elongate mineral particles. In order to prepare samples of fibers for toxicology studies, it is necessary to develop and evaluate methods for separating fibers by length in the micrometer size range. In this study, we have filtered an aerosol of fibers through nylon screens to investigate whether such screens can efficiently remove the long fibers (L >20 μm, a typical macrophage size) from the aerosol stream. Such a sample, deficient in long fibers, could then be used as the control in a toxicology study to investigate the role of length. A well-dispersed aerosol of glass fibers (a surrogate for asbestos) was generated by vortex shaking a Japan Fibrous Material Research Association (JFMRA) glass fiber powder. Fibers were collected on a mixed cellulose ester (MCE) filter, imaged with phase contrast microscopy (PCM) and lengths were measured. Length distributions of the fibers that penetrated through various screens (10, 20 and 60 μm mesh sizes) were analyzed; additional study was made of fibers that penetrated through double screen and centrally blocked screen configurations. Single screens were not particularly efficient in removing the long fibers; however, the alternative configurations, especially the centrally blocked screen configuration, yielded samples substantially free of the long fibers. PMID:24417374
Li, Xue-Bo; Wang, Qing-Shan; Feng, Yu; Ning, Shu-Hua; Miao, Yuan-Ying; Wang, Ye-Quan; Li, Hong-Wei
2014-11-01
Forensic DNA analysis of sexual assault evidence requires unambiguous differentiation of DNA profiles in mixed samples. To investigate the feasibility of magnetic bead-based separation of sperm from cell mixtures using a monoclonal antibody against MOSPD3 (motile sperm domain-containing protein 3), 30 cell samples were prepared by mixing 10(4) female buccal epithelial cells with sperm cells of varying densities (10(3), 10(4), or 10(5) cells/mL). Western blot and immunofluorescence assays showed that MOSPD3 was detectable on the membrane of sperm cells, but not in buccal epithelial cells. After biotinylated MOSPD3 antibody was incubated successively with the prepared cell mixtures and avidin-coated magnetic beads, microscopic observation revealed that each sperm cell was bound by two or more magnetic beads, in the head, neck, mid-piece, or flagellum. A full single-source short tandem repeat profile could be obtained in 80% of mixed samples containing 10(3) sperm cells/mL and in all samples containing ≥10(4) sperm cells/mL. For dried vaginal swab specimens, the rate of successful detection was 100% in both flocked and cotton swabs preserved for 1 day, 87.5% in flocked swabs and 40% in cotton swabs preserved for 3 days, and 40% in flocked swabs and 16.67% in cotton swabs preserved for 10 days. Our findings suggest that immunomagnetic bead-based separation is potentially a promising alternative to conventional methods for isolating sperm cells from mixed forensic samples.
Ion exchangers in radioactive waste management: natural Iranian zeolites.
Nilchi, A; Maalek, B; Khanchi, A; Ghanadi Maragheh, M; Bagheri, A; Savoji, K
2006-01-01
Five samples of natural zeolites from different parts of Iran were chosen for this study. In order to characterize and determine their structures, X-ray diffraction and infrared spectrometry were carried out for each sample. The selective absorption properties of each zeolite were found by calculating the distribution coefficient (K(d)) of various simulated wastes which were prepared by spiking the radionuclides with (131)I, (99)Mo, (153)Sm, (140)La and (147)Nd. All the zeolite samples used in this study had extremely high absorption value towards (140)La; clinoptolite from Mianeh and analsite from Ghalehkhargoshi showed good absorption for (147)Nd; clinoptolite from Semnan and clinoptolite from Firozkoh showed high absorption for (153)Sm; mesolite from Arababad Tabas showed good absorption for (99)Mo; and finally mesolite from Arababad Tabas, clinoptolite from Semnan and clinoptolite from Firozkoh could be used to selectively absorb (131)I from the stimulated waste which was prepared. The natural zeolites chosen for these studies show a similar pattern to those synthetic ion exchangers in the literature and in some cases an extremely high selectivity towards certain radioactive elements. Hence the binary separation of radioactive elements could easily be carried out. Furthermore, these zeolites, which are naturally occurring ion exchangers, are viable economically and extremely useful alternatives in this industry.
Stringer, Kate; Kerpelman, Jennifer; Skorikov, Vladimir
2012-09-01
Preparing for an adult career and incorporating a career into one's identity is a key task during the transition to adulthood (Erikson, 1968), and completing developmental tasks is considered a major factor in adjustment (Havinghurst, 1972). Previous research has established associations between overall career preparation in high school and adjustment soon after high school graduation. Differences in the developmental patterns of career preparation dimensions (indecision, planning, and confidence) following high school graduation also have been found. The current study builds on that prior work by examining associations between changes in the dimensions of career preparation and changes in 3 aspects of adjustment (emotional stability, social adaptation, and self-actualization) from 12th grade in high school to 4.5 years after high school graduation in a sample of 454 youths, using latent growth curve analysis. Results showed that career preparation both predicts and is predicted by adjustment. Career confidence was a particularly important predictor of adjustment. Both 12th grade career confidence and changes in confidence over time predicted changes in adjustment and adjustment 4.5 years post-high school. In an alternative model, an increase in emotional stability was predictive of higher career confidence and lower indecision. Results are discussed in the context of developmental theories and the notion that adjustment and career are interrelated processes. PsycINFO Database Record (c) 2012 APA, all rights reserved.
The Effect of Multiple Surface Treatments on Biological Properties of Ti-6Al-4V Alloy
NASA Astrophysics Data System (ADS)
Parsikia, Farhang; Amini, Pupak; Asgari, Sirous
2014-09-01
In this research, the effect of various surface treatments including laser processing, grit blasting and anodizing on chemical structure, surface topography, and bioactivity of Ti-6Al-4V was investigated. Six groups of samples were prepared by a combination of two alternative laser processes, grit blasting and anodizing. Selected samples were first evaluated using microanalysis techniques and contact roughness testing and were then exposed to in vitro environment. Scanning electron microscopy was used to characterize the corresponding final surface morphologies. Weight measurement and atomic absorption tests were employed for determination of bioactivity limits of different surface conditions. Based on the data obtained in this study, low-energy laser processing generally yields a better biological response. The maximum bioactivity was attained in those samples exposed to a three step treatment including low-energy laser treatment followed by grit blasting and anodizing.
Green banana pasta: an alternative for gluten-free diets.
Zandonadi, Renata Puppin; Botelho, Raquel Braz Assunção; Gandolfi, Lenora; Ginani, Janini Selva; Montenegro, Flávio Martins; Pratesi, Riccardo
2012-07-01
The objective of this study was to develop and analyze a gluten-free pasta made with green banana flour. The study was divided into five steps: preparation/selection, chemical, sensory, technological, and statistical analysis. The modified sample presented greater acceptance (84.5% for celiac individuals and 61.2% for nonceliac) than standard samples (53.6% for nonceliac individuals). There was no significant difference between the modified and the standard samples in terms of appearance, aroma, flavor, and overall quality. The modified pastas presented approximately 98% less lipids. Green bananas are considered a subproduct of low commercial value with little industrial use. The possibility of developing gluten-free products with green banana flour can expand the product supply for people with celiac disease and contribute to a more diverse diet. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheele, R.D.
In 1995, available subsegment samples of wastes taken from the Hanford Site underground radioactive waste storage tanks 241-C-112 (C-112) and 241-C-109 (C-109) were reanalyzed to determine the nickel concentrations in the samples and to determine whether the use of a nickel crucible in the analytical sample preparation biased the reported nickel concentrations reported by Simpson and coworkers and in the original report that this report supplements. The reanalysis strategy to determine nickel was to use a sodium peroxide flux in a zirconium crucible instead of the previously used potassium hydroxide flux in a nickel crucible. This supplemental report provides themore » results of the reanalyses and updates tables from the original report which reflect the new nickel analyses. Nickel is important with respect to management of the potentially reactive ferrocyanide wastes as it is one of the key defining characteristics of the solids that resulted from scavenging radiocesium using ferrocyanides. In Hanford Site wastes, few other processes introduced nickel into the wastes other than radiocobalt scavenging, which was often coupled with the ferrocyanide-scavenging process. Thus the presence of nickel in a waste provides strong evidence that the original waste was or contained ferrocyanide waste at one time. Given the potential import of nickel as a defining characteristic and marker for ferrocyanide wastes, the Pacific Northwest Laboratory`s (PNL) Analytical Chemistry Laboratory (ACL) reanalyzed available samples from tanks C-112 and C-109 using inductively coupled argon plasma/atomic emission spectrometry (ICP/AES) and an alternative sample preparation method which precluded contamination of the analytical samples with nickel.« less
NASA Astrophysics Data System (ADS)
Kaya, Hatice; Bulut, Osman; Kamali, Ali Reza; Ege, Duygu
2018-06-01
Favorable implant-tissue interactions are crucial to achieve successful osseointegration of the implants. Poly(ether ether ketone) (PEEK) is an interesting alternative to titanium in orthopedics because of its low cost, high biocompatibility and comparable mechanical properties with cancellous bone. Despite these advantages; however, the untreated surface of PEEK fails to osseointegrate due to its bioinert and hydrophobic behavior. This paper deals with the surface modification of PEEK with a novel method. For this, PEEK was first treated with concentrated sulfuric acid to prepare sulfonated PEEK (SPEEK) films using a solvent casting method. Then, 1 and 2 wt% multi-walled carbon nanotube was incorporated into SPEEK to form nanocomposite films. The samples were characterized with Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy. After successful preparation of the nanocomposite films, L-arginine was covalently conjugated on the nanocomposite films to further improve their surface properties. Subsequently, the samples were characterized using X-ray Photoemission Spectroscopy (XPS), water contact angle measurements and Atomic Force Microscopy (AFM) and Dynamic Mechanical Thermal Analysis (DMTA). Finally, cell culture studies were carried out by using Alamar Blue assay to evaluate the biocompatibility of the films. The results obtained indicate the successful preparation of L-arginine-conjugated MWCNT/SPEEK nanocomposite films. The modified surface shows potential to improve implants' mechanical and biological performances.
Lee, Hye-Seung; Burkhardt, Brant R; McLeod, Wendy; Smith, Susan; Eberhard, Chris; Lynch, Kristian; Hadley, David; Rewers, Marian; Simell, Olli; She, Jin-Xiong; Hagopian, Bill; Lernmark, Ake; Akolkar, Beena; Ziegler, Anette G; Krischer, Jeffrey P
2014-07-01
The Environmental Determinants of Diabetes in the Young planned biomarker discovery studies on longitudinal samples for persistent confirmed islet cell autoantibodies and type 1 diabetes using dietary biomarkers, metabolomics, microbiome/viral metagenomics and gene expression. This article describes the details of planning The Environmental Determinants of Diabetes in the Young biomarker discovery studies using a nested case-control design that was chosen as an alternative to the full cohort analysis. In the frame of a nested case-control design, it guides the choice of matching factors, selection of controls, preparation of external quality control samples and reduction of batch effects along with proper sample allocation. Our design is to reduce potential bias and retain study power while reducing the costs by limiting the numbers of samples requiring laboratory analyses. It also covers two primary end points (the occurrence of diabetes-related autoantibodies and the diagnosis of type 1 diabetes). The resulting list of case-control matched samples for each laboratory was augmented with external quality control samples. Copyright © 2013 John Wiley & Sons, Ltd.
Shlapa, Yulia; Kulyk, Mykola; Kalita, Viktor; Polek, Taras; Tovstolytkin, Alexandr; Greneche, Jean-Marc; Solopan, Sergii; Belous, Anatolii
2016-12-01
Fe-doped La0.77Sr0.23Mn1 - y Fe y O3 nanoparticles have been synthesized by sol-gel method, and ceramic samples based on them were sintered at 1613 K. Crystallographic and magnetic properties of obtained nanoparticles and ceramic samples have been studied. It has been established that cell volume for nanoparticles increases with growing of iron content, while this dependence displays an opposite trend in the case of ceramic samples. Mössbauer investigations have shown that in all samples, the oxidation state of iron is +3. According to magnetic studies, at room temperature, both nanoparticles and ceramic samples with y ≤ 0.06 display superparamagnetic properties and samples with y ≥ 0.08 are paramagnetic. Magnetic fluids based on La0.77Sr0.23Mn1 - y Fe y O3 nanoparticles and aqua solution of agarose have been prepared. It has been established that heating efficiency of nanoparticles under an alternating magnetic field decreases with growing of iron content.
Final report on cermet high-level waste forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobisk, E.H.; Quinby, T.C.; Aaron, W.S.
1981-08-01
Cermets are being developed as an alternate method for the fixation of defense and commercial high level radioactive waste in a terminal disposal form. Following initial feasibility assessments of this waste form, consisting of ceramic particles dispersed in an iron-nickel base alloy, significantly improved processing methods were developed. The characterization of cermets has continued through property determinations on samples prepared by various methods from a variety of simulated and actual high-level wastes. This report describes the status of development of the cermet waste form as it has evolved since 1977. 6 tables, 18 figures.
McGuirt, Delaney
2016-09-01
To assess alternatives to sedation and general anesthesia to prepare children for magnetic resonance (MR) imaging examinations. Online databases were searched for articles discussing methods of preparing children for MR imaging procedures. Because of the large number of articles returned, criteria were limited to only studies that prepared patients without the use of sedation or general anesthesia. Twenty-four studies were deemed appropriate for inclusion in the review. The following methods emerged as alternatives to pediatric sedation: mock scanners, MR-compatible audiovisual systems, feed-sleep manipulation, play therapy, infant incubators/immobilizers, photo diaries, sucrose solutions, and guided imagery. The approaches with the most extensive research were mock MR scanners and feed-sleep manipulation. Evidence supports the use of these alternative techniques as valid substitutes for pediatric sedation and general anesthesia. To reduce the risks associated with sedation of pediatric patients, institutions could implement the alternatives discussed in this review. Cost analyses should be conducted first because some methods are more expensive than others. Finally, further research is needed to better assess the effectiveness of lesser-practiced methods, including photo diaries, sucrose solutions, and guided imagery. ©2016 American Society of Radiologic Technologists.
Metadynamics for training neural network model chemistries: A competitive assessment
NASA Astrophysics Data System (ADS)
Herr, John E.; Yao, Kun; McIntyre, Ryker; Toth, David W.; Parkhill, John
2018-06-01
Neural network model chemistries (NNMCs) promise to facilitate the accurate exploration of chemical space and simulation of large reactive systems. One important path to improving these models is to add layers of physical detail, especially long-range forces. At short range, however, these models are data driven and data limited. Little is systematically known about how data should be sampled, and "test data" chosen randomly from some sampling techniques can provide poor information about generality. If the sampling method is narrow, "test error" can appear encouragingly tiny while the model fails catastrophically elsewhere. In this manuscript, we competitively evaluate two common sampling methods: molecular dynamics (MD), normal-mode sampling, and one uncommon alternative, Metadynamics (MetaMD), for preparing training geometries. We show that MD is an inefficient sampling method in the sense that additional samples do not improve generality. We also show that MetaMD is easily implemented in any NNMC software package with cost that scales linearly with the number of atoms in a sample molecule. MetaMD is a black-box way to ensure samples always reach out to new regions of chemical space, while remaining relevant to chemistry near kbT. It is a cheap tool to address the issue of generalization.
Baedecker, P.A.; Grossman, J.N.
1995-01-01
A PC based system has been developed for the analysis of gamma-ray spectra and for the complete reduction of data from INAA experiments, including software to average the results from mulitple lines and multiple countings and to produce a final report of analysis. Graphics algorithms may be called for the analysis of complex spectral features, to compare the data from alternate photopeaks and to evaluate detector performance during a given counting cycle. A database of results for control samples can be used to prepare quality control charts to evaluate long term precision and to search for systemic variations in data on reference samples as a function of time. The entire software library can be accessed through a user-friendly menu interface with internal help.
Gad, Haidy A; Bouzabata, Amel
2017-12-15
Turmeric (Curcuma longa L.) belongs to the family Zingiberaceae that is widely used as a spice in food preparations in addition to its biological activities. UV, FT-IR, 1 H NMR in addition to HPLC were applied to construct a metabolic fingerprint for Turmeric in an attempt to assess its quality. 30 samples were analyzed, and then principal component analysis (PCA) and hierarchical clustering analysis (HCA) were utilized to assess the differences and similarities between collected samples. PCA score plot based on both HPLC and UV spectroscopy showed the same discriminatory pattern, where the samples were segregated into four main groups depending on their total curcuminoids content. The results revealed that UV could be utilized as a simple and rapid alternative for HPLC. However, FT-IR failed to discriminate between the same species. By applying 1 H NMR, the metabolic variability between samples was more evident in the essential oils/fatty acid region. Copyright © 2017 Elsevier Ltd. All rights reserved.
Schwaighofer, Andreas; Kuligowski, Julia; Quintás, Guillermo; Mayer, Helmut K; Lendl, Bernhard
2018-06-30
Analysis of proteins in bovine milk is usually tackled by time-consuming analytical approaches involving wet-chemical, multi-step sample clean-up procedures. The use of external cavity-quantum cascade laser (EC-QCL) based IR spectroscopy was evaluated as an alternative screening tool for direct and simultaneous quantification of individual proteins (i.e. casein and β-lactoglobulin) and total protein content in commercial bovine milk samples. Mid-IR spectra of protein standard mixtures were used for building partial least squares (PLS) regression models. A sample set comprising different milk types (pasteurized; differently processed extended shelf life, ESL; ultra-high temperature, UHT) was analysed and results were compared to reference methods. Concentration values of the QCL-IR spectroscopy approach obtained within several minutes are in good agreement with reference methods involving multiple sample preparation steps. The potential application as a fast screening method for estimating the heat load applied to liquid milk is demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.
Alternative Routes to Teacher Certification. Occasional Paper Series 20
ERIC Educational Resources Information Center
Silin, Jonathan G., Ed.; Snyder, Jon; Barry, Miranda; Samuels, Sarah; Sacks, Ariel; Ellenzweig, Allen
2008-01-01
Alternative routes to teacher preparation are clearly here to stay. A growing research literature on non-traditional pathways suggests the complexity of the task ahead. This report offers new teachers the opportunity to tell their own stories in their own words. In "Alternative Certification and Alternative Pathways: A Personal Take on a Core…
The Teenagers' Guide to School outside the Box.
ERIC Educational Resources Information Center
Greene, Rebecca
This book, which is intended for high school students, explains how to scout out alternative learning opportunities available to high school students and how to select, prepare for, and make the most of alternative programs. The book begins with a definition of alternative learning and a brief overview of the many types of alternative learning…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-11
... alternative, a reduced-intensity development alternative, a non- gaming alternative, and an alternate site... application, determination of the site's eligibility for gaming, compliance with the Clean Water Act, and..., phone number, e-mail address, or other personal identifying information in your comment, you should be...
ERIC Educational Resources Information Center
Stoddart, Trish; Floden, Robert E.
States have created "alternate" routes to teacher certification. Comparison of alternate and college-based programs reveals clear trends in recruitment but a mixed picture regarding development of expertise. Alternate certification represents a radical departure from the current norm of teacher preparation. Several factors have led to…
Evaluation of supercritical CO2 dried cellulose aerogels as nano-biomaterials
NASA Astrophysics Data System (ADS)
Lee, Sinah; Kang, Kyu-Young; Jeong, Myung-Joon; Potthast, Antje; Liebner, Falk
2017-10-01
Cellulose is the renewable, biodegradable and abundant resource and is suggested as an alternative material to silica due to the high price and environmental load of silica. The first step for cellulose aerogel production is to dissolve cellulose, and hydrated calcium thiocyanate molten salt is one of the most effective solvents for preparing porous material. Cellulose aerogels were prepared from dissolved cellulose samples of different degree of polymerization (DP) and drying methods, and tested with shrinkage, density and mechanical strength. Supercritical CO2 dried cellulose aerogels shrank less compared to freeze-dried cellulose aerogels, whereas the densities were increased according to the DP increases in both cellulose aerogels. Furthermore, scanning electron microscope (SEM) images showed that the higher DP cellulose aerogels were more uniform with micro-porous structure. Regarding the mechanical strength of cellulose aerogels, supercritical CO2 dried cellulose aerogels with higher molecular weight were much more solid.
Imaging plasmodesmata with high-resolution scanning electron microscopy.
Barton, Deborah A; Overall, Robyn L
2015-01-01
High-resolution scanning electron microscopy (HRSEM) is an effective tool to investigate the distribution of plasmodesmata within plant cell walls as well as to probe their complex, three-dimensional architecture. It is a useful alternative to traditional transmission electron microscopy (TEM) in which plasmodesmata are sectioned to reveal their internal substructures. Benefits of adopting an HRSEM approach to studies of plasmodesmata are that the specimen preparation methods are less complex and time consuming than for TEM, many plasmodesmata within a large region of tissue can be imaged in a single session, and three-dimensional information is readily available without the need for reconstructing TEM serial sections or employing transmission electron tomography, both of which are lengthy processes. Here we describe methods to prepare plant samples for HRSEM using pre- or postfixation extraction of cellular material in order to visualize plasmodesmata embedded within plant cell walls.
Simple preparation of Fenton catalyst@bacterial cellulose for waste water treatment
NASA Astrophysics Data System (ADS)
Wibowo, Arie; Febi Indrawan, Radian; Triadhi, Untung; Hasdi Aimon, Akfiny; Iskandar, Ferry; Ardy, Husaini
2018-02-01
Heterogeneous fenton catalyst is one of the attractive technologies for destruction of persistent and non-biodegradable pollutant in wastewater, because it can be used in wide range of pH and recyclable. Herein, commercial bacterial celluloses (BCs) were used as an alternative support of fenton catalyst to improve their catalytic activity. Scanning Electron Microscope (SEM) observations indicated that the presence of BCs and decreasing precursor concentration might promote formation of smaller particle sizes of catalyst from 3.5 μm of bare catalyst to 0.7 μm of catalyst@BC. UV-vis measurement showed that fast degradation of dyes with half-time degradation at around 25 min was observed in sample using catalyst@BCs with precursor concentration of 0.01 M. Successful preparation of heterogeneous fenton catalyst with smaller particle size and better catalytic activity is important for their application in wastewater treatment.
Mechanized instrumentation of root canals oscillating systems.
Leonardo, Renato de Toledo; Puente, Carlos Garcia; Jaime, Alejandro; Jent, Carol
2013-01-01
Cleaning and shaping are important steps in the root canal treatment. Despite the technological advances in endodontics, K and Hedstroen files are still widely used. In an attempt to be more effective in preparing the root canals, faster and more cutting efficient kinematic, alloys and design alternatives utilizing mechanically oscillating or rotary files are proposed. Even with all these technological innovating alternatives, the preparation of root canals remains a challenge.
Preparing Healthy Young Children for Hospitalization: A Rationale and Proposal.
ERIC Educational Resources Information Center
Poster, Elizabeth C.
1984-01-01
Proposes a precrisis curriculum for nursery and elementary schools to prepare healthy young children for hospitalization as an alternative to current preadmission preparation programs. Key elements include such stress-immunization techniques as systematic desensitization, modeling, and rehearsal. (AS)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
..., and an alternatives analysis study. Early scoping notification for the alternatives analysis phase was... alternatives analysis findings, and other background technical reports are available on the project Web site... about the proposed [[Page 36299
Effect of preparation methods and doping on the structural and tunable emissions of CdS
NASA Astrophysics Data System (ADS)
Mohamed, Mohamed Bakr; Abdel-Kader, M. H.; Alhazime, Ali A.; Almarashi, Jamal Q. M.
2018-03-01
Fe, Mn and Mg doped CdS samples were prepared by thermolysis method in air and under flow of nitrogen. Structural, compositional and optical properties of the prepared samples were investigated using x-ray powder diffraction (XRD), scanning electron microscope (SEM/EDS mapping), Fourier transform infrared red (FTIR), UV-vis absorption and photoluminescence (PL) spectroscopes. Rietveld refinement of x-ray data showed that all the undoped and doped CdS samples prepared in air and under flow of nitrogen have both cubic and hexagonal structures. The percentages of hexagonal and cubic phases for all prepared samples were determined. The crystallite size increased for CdS prepared under flow of N2 compared with the sample prepared in air. The energy gap of all the samples was calculated using UV data. The intensity of PL emission changed according to the method of preparation and the kind of doping elements. PL emission revealed a blue shift for CdS prepared in air compared with CdS prepared under flow of nitrogen; also all doped samples showed a red shift of PL spectra compared with undoped samples. Undoped and doped CdS with Fe and Mg samples emitted violet and blue sub-spectra. Mn doped CdS prepared in air revealed violet, blue and yellow sub-spectra, while the sample prepared under flow of N2 emitted violet, blue and green sub-spectra.
Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S
2015-12-01
We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.
Nicholls, C; Karim, K; Piletsky, S; Saini, S; Setford, S
2006-01-15
The preparation of a molecularly imprinted polymer (MIP) for pentachlorophenol is described together with two alternative reporter derivatives for use in a displacement imprinted polymer receptor analysis (DIPRA) format procedure. In this procedure, alternative reporter molecules were rebound to the synthetic receptor sites and their displacement by the target analyte was employed as the basis of a simple procedure for the measurement of chlorophenols in water and packaging material samples. Water samples were extracted using the standard procedure (EPA 528) and a detection limit of 0.5 microg l(-1) was achieved using the DIPRA detection method, with good agreement between the displacement technique and GC-ECD analysis. A variety of packaging materials, extracted using a buffered detergent solution were also analysed using the DIPRA procedure and showed good agreement with GC results. In addition, investigation of the cross-reactivity of a range of pesticides and materials commonly encountered in environmental analysis indicated the procedure gave good discrimination between pesticides bearing a chlorophenolic moiety and other materials. The procedure is considered highly suitable for use as a rapid field-test method or for incorporation into a test kit device.
Improvement of immunoassay detection system by using alternating current magnetic susceptibility
NASA Astrophysics Data System (ADS)
Kawabata, R.; Mizoguchi, T.; Kandori, A.
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Improvement of immunoassay detection system by using alternating current magnetic susceptibility.
Kawabata, R; Mizoguchi, T; Kandori, A
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Iorgulescu, E; Voicu, V A; Sârbu, C; Tache, F; Albu, F; Medvedovici, A
2016-08-01
The influence of the experimental variability (instrumental repeatability, instrumental intermediate precision and sample preparation variability) and data pre-processing (normalization, peak alignment, background subtraction) on the discrimination power of multivariate data analysis methods (Principal Component Analysis -PCA- and Cluster Analysis -CA-) as well as a new algorithm based on linear regression was studied. Data used in the study were obtained through positive or negative ion monitoring electrospray mass spectrometry (+/-ESI/MS) and reversed phase liquid chromatography/UV spectrometric detection (RPLC/UV) applied to green tea extracts. Extractions in ethanol and heated water infusion were used as sample preparation procedures. The multivariate methods were directly applied to mass spectra and chromatograms, involving strictly a holistic comparison of shapes, without assignment of any structural identity to compounds. An alternative data interpretation based on linear regression analysis mutually applied to data series is also discussed. Slopes, intercepts and correlation coefficients produced by the linear regression analysis applied on pairs of very large experimental data series successfully retain information resulting from high frequency instrumental acquisition rates, obviously better defining the profiles being compared. Consequently, each type of sample or comparison between samples produces in the Cartesian space an ellipsoidal volume defined by the normal variation intervals of the slope, intercept and correlation coefficient. Distances between volumes graphically illustrates (dis)similarities between compared data. The instrumental intermediate precision had the major effect on the discrimination power of the multivariate data analysis methods. Mass spectra produced through ionization from liquid state in atmospheric pressure conditions of bulk complex mixtures resulting from extracted materials of natural origins provided an excellent data basis for multivariate analysis methods, equivalent to data resulting from chromatographic separations. The alternative evaluation of very large data series based on linear regression analysis produced information equivalent to results obtained through application of PCA an CA. Copyright © 2016 Elsevier B.V. All rights reserved.
Niederkofler, Eric E.; Phillips, David A.; Krastins, Bryan; Kulasingam, Vathany; Kiernan, Urban A.; Tubbs, Kemmons A.; Peterman, Scott M.; Prakash, Amol; Diamandis, Eleftherios P.; Lopez, Mary F.; Nedelkov, Dobrin
2013-01-01
Insulin-like growth factor 1 (IGF1) is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM) mode. The resulting quantitative mass spectrometric immunoassay (MSIA) exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories. PMID:24278387
Application of a Smartphone Metabolomics Platform to the Authentication of Schisandra sinensis.
Kwon, Hyuk Nam; Phan, Hong-Duc; Xu, Wen Jun; Ko, Yoon-Joo; Park, Sunghyouk
2016-05-01
Herbal medicines have been used for a long time all around the world. Since the quality of herbal preparations depends on the source of herbal materials, there has been a strong need to develop methods to correctly identify the origin of materials. To develop a smartphone metabolomics platform as a simpler and low-cost alternative for the identification of herbal material source. Schisandra sinensis extracts from Korea and China were prepared. The visible spectra of all samples were measured by a smartphone spectrometer platform. This platform included all the necessary measures built-in for the metabolomics research: data acquisition, processing, chemometric analysis and visualisation of the results. The result of the smartphone metabolomics platform was compared to that of NMR-based metabolomics, suggesting the feasibility of smartphone platform in metabolomics research. The smartphone metabolomics platform gave similar results to the NMR method, showing good separation between Korean and Chinese materials and correct predictability for all test samples. With its accuracy and advantages of affordability, user-friendliness, and portability, the smartphone metabolomics platform could be applied to the authentication of other medicinal plants. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Sterren, Vanesa B; Aiassa, Virginia; Garnero, Claudia; Linck, Yamila Garro; Chattah, Ana K; Monti, Gustavo A; Longhi, Marcela R; Zoppi, Ariana
2017-11-01
Chloramphenicol is an old antibiotic agent that is re-emerging as a valuable alternative for the treatment of multidrug-resistant pathogens. However, it exhibits suboptimal biopharmaceutical properties and toxicity profiles. In this work, chloramphenicol was combined with essential amino acids (arginine, cysteine, glycine, and leucine) with the aim of improving its dissolution rate and reduce its toxicity towards leukocytes. The chloramphenicol/amino acid solid samples were prepared by freeze-drying method and characterized in the solid state by using Fourier transform infrared spectroscopy, powder X-ray diffraction, differential scanning calorimetry, scanning electron microscopy, and solid-state nuclear magnetic resonance. The dissolution properties, antimicrobial activity, reactive oxygen species production, and stability of the different samples were studied. The dissolution rate of all combinations was significantly increased in comparison to that of the pure active pharmaceutical ingredient. Additionally, oxidative stress production in human leukocytes caused by chloramphenicol was decreased in the chloramphenicol/amino acid combinations, while the antimicrobial activity of the antibiotic was maintained. The CAP:Leu binary combination resulted in the most outstanding solid system makes it suitable candidate for the development of pharmaceutical formulations of this antimicrobial agent with an improved safety profile.
NASA Astrophysics Data System (ADS)
Zhang, Xiao; Jiang, Bin; Guo, Jinxue; Xie, Yaping; Tang, Lin
2014-12-01
The major challenge to promote the commercialization of SnO2 anode materials is to construct unique structures and/or composites that could alleviate the volume effect and extend the lifespan. This study develops an efficient synthetic solution for the preparation of mesoporous SnO2 nanosheets, which involves an evaporation-induced selfassembly process and the following thermal treatment. Surfactant F127 is used as the soft template to form abundant cores. The as-prepared sample intrinsically inherits flexible sheet-like structure and porous features, as characterized with XRD, SEM, TEM and BET techniques. Based on these combining structural benefits, the sample is utilized as anode materials for lithium-ion batteries and exhibits excellent Li+ storage performance such as large and stable reversible capacity, good rate capability, and especially the outstanding durable cycling life of over 1000 cycles, which meets the demands of practical applications. The structural changes of SnO2 nanosheets are observed from the decomposed electrodes after different electrochemical cycles. Moreover, this synthesis strategy may offer an alternative and universal approach for synthesis of other transitional metal oxides or their binary composites as high-performance anode materials for lithium-ion batteries.
Brits, Martin; de Vos, Jayne; Weiss, Jana M; Rohwer, Egmont R; de Boer, Jacob
2016-12-01
World-wide, the prevalence of brominated flame retardants (BFRs) is well documented for routine analysis of environmental and biological matrices. There is, however, limited information on these compounds in the African environment and insufficient information on the analytical approaches used to obtain data. This paper presents a review on BFR levels in the African environment and the various analytical methodologies specifically applied in Africa for polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls and alternative-BFRs. The analyses include liquid sample preparation using liquid-liquid and solid phase extraction and solid sample preparation involving Soxhlet extraction, with ultrasound-assisted extraction increasingly being applied. Instrumental detection techniques were limited to gas chromatography coupled with electron capture detector and electron impact ionisation with single quadrupole mass spectrometers. Information on congener profile prevalence in indoor dust, soil, aquatic environment (water, sediment, and aquatic organisms), eggs, wastewater treatment plant compartments, landfills (leachate and sediment) and breast milk are presented. Although PBDEs were inconsistently detected, contamination was reported for all investigated matrices in the African environment. The manifestation in remote regions indicates the ubiquitous prevalence and long-range transport of these compounds. Levels in sediment, and breast milk from some African countries were higher than reported for Asia and Europe. Due to limited data or non-detection of alternative-BFRs, it is unclear whether banned formulations were replaced in Africa. Most of the data reported for BFR levels in Africa were obtained in non-African laboratories or in South Africa and formed the basis for our discussion of reported contamination levels and related methodologies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Proteomics of exhaled breath: methodological nuances and pitfalls.
Kurova, Viktoria S; Anaev, Eldar C; Kononikhin, Alexey S; Fedorchenko, Kristina Yu; Popov, Igor A; Kalupov, Timothey L; Bratanov, Dmitriy O; Nikolaev, Eugenie N; Varfolomeev, Sergey D
2009-01-01
The analysis of exhaled breath condensate (EBC) can be an alternative to traditional endoscopic sampling of lower respiratory tract secretions. This is a simple non-invasive method of diagnosing respiratory diseases, in particular, respiratory inflammatory processes. Samples were collected with a special device-condenser (ECoScreen, VIASYS Healthcare, Germany), then treated with trypsin according to the proteomics protocol for standard protein mixtures and analyzed by nanoflow high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) with a 7-Tesla Finnigan LTQ-FT mass spectrometer (Thermo Electron, Germany). Mascot software (Matrixscience) was used for screening the database NCBInr for proteins corresponding to the peptide maps that were obtained. EBCs from 17 young healthy non-smoking donors were collected. Different methods for concentrating protein were compared in order to optimize EBC preparations for proteomic analysis. The procedure that was chosen allowed identification of proteins exhaled by healthy people. The major proteins in the condensates were cytoskeletal keratins. Another 12 proteins were identified in EBC from healthy non-smokers. Some keratins were found in the ambient air and may be considered exogenous components of exhaled air. Knowledge of the normal proteome of exhaled breath allows one to look for biomarkers of different disease states in EBC. Proteins in ambient air can be identified in the respiratory tract and should be excluded from the analysis of the proteome of EBC. The results obtained allowed us to choose the most effective procedure of sample preparation when working with samples containing very low protein concentrations.
Dotterer, Sally K; Forbes, Robert A; Hammill, Cynthia L
2011-04-05
Case studies are presented demonstrating how exposure to traces of transition metals such as copper and/or iron during sample preparation or analysis can impact the accuracy of purity analysis of pharmaceuticals. Some compounds, such as phenols and indoles, react with metals in the presence of oxygen to produce metal-induced oxidative decomposition products. Compounds susceptible to metal-induced decomposition can degrade following preparation for purity analysis leading to falsely high impurity results. Our work has shown even metals at levels below 0.1 ppm can negatively impact susceptible compounds. Falsely low results are also possible when the impurities themselves react with metals and degrade prior to analysis. Traces of metals in the HPLC mobile phase can lead to chromatographic artifacts, affecting the reproducibility of purity results. To understand and mitigate the impact of metal induced decomposition, a proactive strategy is presented. The pharmaceutical would first be tested for reactivity with specific transition metals in the sample solvent/diluents and in the HPLC mobile phase. If found to be reactive, alternative sample diluents and/or mobile phases with less reactive solvents or addition of a metal chelator would be explored. If unsuccessful, glassware cleaning or sample solution refrigeration could be investigated. By employing this strategy during method development, robust purity methods would be delivered to the quality control laboratories, preventing future problems from potential sporadic contamination of glassware with metals. Copyright © 2010 Elsevier B.V. All rights reserved.
Kaygili, Omer; Ates, Tankut; Keser, Serhat; Al-Ghamdi, Ahmed A; Yakuphanoglu, Fahrettin
2014-08-14
The hydroxyapatite (HAp) samples in the presence of various amounts of ethylenediamine tetraacetic acid (EDTA) were prepared by sol-gel method. The effects of EDTA on the crystallinity, phase structure, chemical, micro-structural and dielectric properties of HAp samples were investigated. With the addition of EDTA, the average crystallite size of the HAp samples is gradually decreased from 30 to 22 nm and the crystallinity is in the range of 65-71%. The values of the lattice parameters (a and c) and volume of the unit cell are decreased by stages with the addition of EDTA. The dielectric parameters such as relative permittivity, dielectric loss and relaxation time are affected by the adding of EDTA. The alternating current conductivity of the as-synthesized hydroxyapatites increases with the increasing frequency and obeys the universal power law behavior. The HAp samples exhibit a non-Debye relaxation mechanism. The obtained results that the dielectrical parameters of the HAp sample can be controlled by EDTA. Copyright © 2014 Elsevier B.V. All rights reserved.
Optical coherence tomography for blood glucose monitoring through signal attenuation
NASA Astrophysics Data System (ADS)
De Pretto, Lucas R.; Yoshimura, Tania M.; Ribeiro, Martha S.; de Freitas, Anderson Z.
2016-03-01
Development of non-invasive techniques for glucose monitoring is crucial to improve glucose control and treatment adherence in patients with diabetes. Hereafter, Optical Coherence Tomography (OCT) may offer a good alternative for portable glucometers, since it uses light to probe samples. Changes in the object of interest can alter the intensity of light returning from the sample and, through it, one can estimate the sample's attenuation coefficient (μt) of light. In this work, we aimed to explore the behavior of μt of mouse's blood under increasing glucose concentrations. Different samples were prepared in four glucose concentrations using a mixture of heparinized blood, phosphate buffer saline and glucose. Blood glucose concentrations were measured with a blood glucometer, for reference. We have also prepared other samples diluting the blood in isotonic saline solution to check the effect of a higher multiple-scattering component on the ability of the technique to differentiate glucose levels based on μt. The OCT system used was a commercial Spectral Radar OCT with 930 nm central wavelength and spectral bandwidth (FWHM) of 100 nm. The system proved to be sensitive for all blood glucose concentrations tested, with good correlations with the obtained attenuation coefficients. A linear tendency was observed, with an increase in attenuation with higher values of glucose. Statistical difference was observed between all groups (p<0.001). This work opens the possibility towards a non-invasive diagnostic modality using OCT for glycemic control, which eliminates the use of analytes and/or test strips, as in the case with commercially available glucometers.
Jiang, Xueliang; Yang, Zhen; Wang, Zhijie; Zhang, Fuqing; You, Feng
2018-01-01
Barium titanate/nitrile butadiene rubber (BT/NBR) and polyurethane (PU) foam were combined to prepare a sound-absorbing material with an alternating multilayered structure. The effects of the cell size of PU foam and the alternating unit number on the sound absorption property of the material were investigated. The results show that the sound absorption efficiency at a low frequency increased when decreasing the cell size of PU foam layer. With the increasing of the alternating unit number, the material shows the sound absorption effect in a wider bandwidth of frequency. The BT/NBR-PU foam composites with alternating multilayered structure have an excellent sound absorption property at low frequency due to the organic combination of airflow resistivity, resonance absorption, and interface dissipation. PMID:29565321
Jiang, Xueliang; Yang, Zhen; Wang, Zhijie; Zhang, Fuqing; You, Feng; Yao, Chu
2018-03-22
Barium titanate/nitrile butadiene rubber (BT/NBR) and polyurethane (PU) foam were combined to prepare a sound-absorbing material with an alternating multilayered structure. The effects of the cell size of PU foam and the alternating unit number on the sound absorption property of the material were investigated. The results show that the sound absorption efficiency at a low frequency increased when decreasing the cell size of PU foam layer. With the increasing of the alternating unit number, the material shows the sound absorption effect in a wider bandwidth of frequency. The BT/NBR-PU foam composites with alternating multilayered structure have an excellent sound absorption property at low frequency due to the organic combination of airflow resistivity, resonance absorption, and interface dissipation.
Preparing Transformational School Leaders: An Investigation into Leadership Style
ERIC Educational Resources Information Center
Murgel, Julie C.
2011-01-01
Since traditional principal preparation programs were scrutinized for inadequately training 21st century principals, alternative principal programs were designed to prepare principals to improve the US educational system and student achievement. One particular innovative program, the Daly Leadership Program, was collaboratively developed between…
Selection of reference standard during method development using the analytical hierarchy process.
Sun, Wan-yang; Tong, Ling; Li, Dong-xiang; Huang, Jing-yi; Zhou, Shui-ping; Sun, Henry; Bi, Kai-shun
2015-03-25
Reference standard is critical for ensuring reliable and accurate method performance. One important issue is how to select the ideal one from the alternatives. Unlike the optimization of parameters, the criteria of the reference standard are always immeasurable. The aim of this paper is to recommend a quantitative approach for the selection of reference standard during method development based on the analytical hierarchy process (AHP) as a decision-making tool. Six alternative single reference standards were assessed in quantitative analysis of six phenolic acids from Salvia Miltiorrhiza and its preparations by using ultra-performance liquid chromatography. The AHP model simultaneously considered six criteria related to reference standard characteristics and method performance, containing feasibility to obtain, abundance in samples, chemical stability, accuracy, precision and robustness. The priority of each alternative was calculated using standard AHP analysis method. The results showed that protocatechuic aldehyde is the ideal reference standard, and rosmarinic acid is about 79.8% ability as the second choice. The determination results successfully verified the evaluation ability of this model. The AHP allowed us comprehensive considering the benefits and risks of the alternatives. It was an effective and practical tool for optimization of reference standards during method development. Copyright © 2015 Elsevier B.V. All rights reserved.
Vanadium phosphorus oxide (VPO) has been prepared using ultrasound and microwave irradiation methods and compared with the catalyst prepared by conventional method for both the phase composition and activity for hydrocarbon oxidation. It is found that ultrasound irradiation metho...
7 CFR 27.21 - Preparation of samples of cotton.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...
7 CFR 27.21 - Preparation of samples of cotton.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...
7 CFR 27.21 - Preparation of samples of cotton.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...
Lessons from an Alternative-Certification Program.
ERIC Educational Resources Information Center
Barkley, Brenda Stallion
1999-01-01
Describes Kentucky's Alternative Training Program for the Preparation of Candidates for Initial Certification, presenting the story of one individual who made a career change to teaching after 15 years as a broadcast journalist. The paper discusses state guidelines, the mentor teacher, the school district alternative training program, the…
Zhang, Qiang; Su, Xianli; Yan, Yonggao; Xie, Hongyao; Liang, Tao; You, Yonghui; Tang, Xinfeng; Uher, Ctirad
2016-02-10
A series of Sb-doped Mg2Si(1-x)Sb(x) compounds with the Sb content x within 0 ≤ x ≤ 0.025 were prepared by self-propagating high-temperature synthesis (SHS) combined with plasma activated sintering (PAS) method in less than 20 min. Thermodynamic parameters of the SHS process, such as adiabatic temperature, ignition temperature, combustion temperature, and propagation speed of the combustion wave, were determined for the first time. Nanoprecipitates were observed for the samples doped with Sb. Thermoelectric properties were characterized in the temperature range of 300-875 K. With the increasing content of Sb, the electrical conductivity σ rises markedly while the Seebeck coefficient α decreases, which is attributed to the increase in carrier concentration. The carrier mobility μ(H) decreases slightly with the increasing carrier concentration but remains larger than the Sb-doped samples prepared by other methods, which is ascribed to the self-purification process associated with the SHS synthesis. In spite of the increasing electrical conductivity with the increasing Sb content x, the overall thermal conductivity κ decreases on account of a significantly falled lattice thermal conductivity κ(L) due to the strong point defect scattering on Sb impurities and possibly enhanced interface scattering on nanoprecipitates. As a result, the sample with x = 0.02 achieves the thermoelectric figure of merit ZT ∼ 0.65 at 873 K, one of the highest values for the Sb-doped binary Mg2Si compounds investigated so far. A subsequent annealing treatment on the sample with x = 0.02 at 773 K for 7 days has resulted in no noticeble changes in the thermoelectric transport properties, indicating an excellent thermal stability of the compounds prepared by the SHS method. Therefore, SHS method can serve as an effective alternative fabrication route to synthesize Mg-Si based themoelectrics and some other functional materials due to the resulting high performance, perfect thermal stability, and feasible production in large scale for commercial application.
NASA Astrophysics Data System (ADS)
Muller, Wayne; Scheuermann, Alexander
2016-04-01
Measuring the electrical permittivity of civil engineering materials is important for a range of ground penetrating radar (GPR) and pavement moisture measurement applications. Compacted unbound granular (UBG) pavement materials present a number of preparation and measurement challenges using conventional characterisation techniques. As an alternative to these methods, a modified free-space (MFS) characterisation approach has previously been investigated. This paper describes recent work to optimise and validate the MFS technique. The research included finite difference time domain (FDTD) modelling to better understand the nature of wave propagation within material samples and the test apparatus. This research led to improvements in the test approach and optimisation of sample sizes. The influence of antenna spacing and sample thickness on the permittivity results was investigated by a series of experiments separating antennas and measuring samples of nylon and water. Permittivity measurements of samples of nylon and water approximately 100 mm and 170 mm thick were also compared, showing consistent results. These measurements also agreed well with surface probe measurements of the nylon sample and literature values for water. The results indicate permittivity estimates of acceptable accuracy can be obtained using the proposed approach, apparatus and sample sizes.
Magiera, Sylwia; Gülmez, Şefika; Michalik, Aleksandra; Baranowska, Irena
2013-08-23
A new approach based on microextraction by packed sorbent (MEPS) and a reversed-phase ultra-high pressure liquid chromatography (UHPLC) method was developed and validated for the determination and quantification of nonsteroidal anti-inflammatory drugs (NSAIDs) (acetylsalicylic acid, ketoprofen, diclofenac, naproxen and ibuprofen) in human urine. The important factors that could influence the extraction were previously screened using the Plackett-Burman design approach. The optimal MEPS extraction conditions were obtained using C18 phase as a sorbent, small sample volume (20μL) and a short time period (approximately 5min) for the entire sample preparation step. The analytes were separated on a core-shell column (Poroshell 120 EC-C18; 100mm×3.0mm; 2.7μm) using a binary mobile phase composed of aqueous 0.1% trifluoroacetic acid and acetonitrile in the gradient elution mode (4.5min of analysis time). The analytical method was fully validated based on linearity, limits of detection (LOD), limits of quantification (LOQ), inter- and intra-day precision and accuracy, and extraction yield. Under optimised conditions, excellent linearity (R(2)>0.9991), limits of detection (1.07-16.2ngmL(-1)) and precision (0.503-9.15% RSD) were observed for the target drugs. The average absolute recoveries of the analysed compounds extracted from the urine samples were 89.4-107%. The proposed method was also applied to the analysis of NSAIDs in human urine. The new approach offers an attractive alternative for the analysis of selected drugs from urine samples, providing several advantages including fewer sample preparation steps, faster sample throughput and ease of performance compared to traditional methodologies. Copyright © 2013 Elsevier B.V. All rights reserved.
Pereira, L S F; Pedrotti, M F; Vecchia, P Dalla; Pereira, J S F; Flores, E M M
2018-06-20
A simple and automated system based on combustion followed by a pyrohydrolysis reaction was proposed for further halogens determination. This system was applied for digestion of soils containing high (90%) and also low (10%) organic matter content for further halogens determination. The following parameters were evaluated: sample mass, use of microcrystalline cellulose and heating time. For analytes absorption, a diluted alkaline solution (6 mL of 25 mmol L -1 NH 4 OH) was used in all experiments. Up to 400 mg of soil with high organic matter content and 100 mg of soil with low organic matter content (mixed with 400 mg of cellulose) could be completely digested using the proposed system. Quantitative results for all halogens were obtained using less than 12 min of sample preparation step (about 1.8 min for sample combustion and 10 min for pyrohydrolysis). The accuracy was evaluated using a certified reference material of coal and spiked samples. No statistical difference was observed between the certified values and results obtained by the proposed method. Additionally, the recoveries obtained using spiked samples were in the range of 98-103% with relative standard deviation values lower than 5%. The limits of quantification obtained for F, Cl, Br and I for soil with high (400 mg of soil) and low (100 mg of soil) organic matter were in the range of 0.01-2 μg g -1 and 0.07-59 μg g -1 , respectively. The proposed system was considered as a simple and suitable alternative for soils digestion for further halogens determination by ion chromatography and inductively coupled plasma mass spectrometry techniques. Copyright © 2018 Elsevier B.V. All rights reserved.
Preparation of Term Papers Based upon a Research-Process Model.
ERIC Educational Resources Information Center
Feldmann, Rodney Mansfield; Schloman, Barbara Frick
1990-01-01
Described is an alternative method of term paper preparation which provides a step-by-step sequence of assignments and provides feedback to the students at all stages in the preparation of the report. An example of this model is provided including 13 sequential assignments. (CW)
Cost-Benefit Analysis for Alternatives to Aliphatic Isocyanate Polyurethanes
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2007-01-01
NASA and Air Force Space Command (AFSPC) have similar missions and therefore similar facilities and structures in similar environments. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. The most common topcoats used in coating systems are polyurethanes that contain isocyanates. Isocyanates are classified as potential human carcinogens and are known to cause cancer in animals. The primary objective of this effort was to demonstrate and validate alternatives to aliphatic isocyanate polyurethanes resulting in one or more isocyanate-free coatings qualified for use at AFSPC and NASA installations participating in this project. This Cost-Benefit Analysis (CBA) quantifies the estimated capital and process costs of coating alternatives and cost savings relative to the current coatings. The estimates in this CBA are to be used for assessing the relative merits of the selected alternatives. The actual economic effects at any specific facility will depend on the alternative material or technology implemented, the number of actual applications converted, future workloads, and other factors . The participants initially considered eighteen (18) alternative coatings as described in the Potential Alternatives Report entitled Potential Alternatives Report for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes, prepared by ITB. Of those, 8 alternatives were selected for testing in accordance with the Joint Test Protocol entitled Joint Test Protocol for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes, and the Field Test Plan entitled Field Evaluations Test Plan for Validation of Alternatives 10 Aliphatic Isocyanate Polyurethanes, both of which were prepared by ITB. A joint Test Report entitled Joint Test Report for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes, prepared by ITB, documents the results of the laboratory and field testing, as well as any test modifications made during the execution of the testing. The coatings selected for evaluation in this CBA are shown in the table below. Only one control coating system is considered in this analysis. These coatings were either downselected for Phase II or performed well enough to be included in the Qualified Products List in the NASA technical standard NASA-STD-5008, Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment.
Direct screening of herbal blends for new synthetic cannabinoids by MALDI-TOF MS.
Gottardo, Rossella; Chiarini, Anna; Dal Prà, Ilaria; Seri, Catia; Rimondo, Claudia; Serpelloni, Giovanni; Armato, Ubaldo; Tagliaro, Franco
2012-01-01
Since 2004, a number of herbal blends containing different synthetic compounds mimicking the pharmacological activity of cannabinoids and displaying a high toxicological potential have appeared in the market. Their availability is mainly based on the so-called "e-commerce", being sold as legal alternatives to cannabis and cannabis derivatives. Although highly selective, sensitive, accurate, and quantitative methods based on GC-MS and LC-MS are available, they lack simplicity, rapidity, versatility and throughput, which are required for product monitoring. In this context, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) offers a simple and rapid operation with high throughput. Thus, the aim of the present work was to develop a MALDI-TOF MS method for the rapid qualitative direct analysis of herbal blend preparations for synthetic cannabinoids to be used as front screening of confiscated clandestine preparations. The sample preparation was limited to herbal blend leaves finely grinding in a mortar and loading onto the MALDI plate followed by addition of 2 µl of the matrix/surfactant mixture [α-cyano-4-hydroxy-cinnamic acid/cetyltrimethylammonium bromide (CTAB)]. After drying, the sample plate was introduced into the ion source for analysis. MALDI-TOF conditions were as follows: mass spectra were analyzed in the range m/z 150-550 by averaging the data from 50 laser shots and using an accelerating voltage of 20 kV. The described method was successfully applied to the screening of 31 commercial herbal blends, previously analyzed by GC-MS. Among the samples analyzed, 21 contained synthetic cannabinoids (namely JWH-018, JWH-073, JWH-081, JWH-250, JWH-210, JWH-019, and AM-694). All the results were in agreement with GC-MS, which was used as the reference technique. Copyright © 2012 John Wiley & Sons, Ltd.
Ho, Mei M; Kairo, Satnam K; Corbel, Michael J
2006-01-01
Tuberculin purified protein derivative (PPD) currently can only be standardised by delayed hypersensitivity skin reactions in sensitised guinea pigs. An in vitro dot blot immunoassay was developed for both identity and confirmation of potency estimation of PPD. Polyclonal antibodies (mainly IgG) were generated and immunoreacted with human, bovine and, to lesser extent, avian PPD preparations. Combining size exclusion chromatography (FPLC-SEC) and dot blot immunoassay, the results showed that PPD preparations were mixtures of very heterogeneous tuberculoproteins ranging in size from very large aggregates to very small degraded molecules. All individual fractions of PPD separated by size were immunoreactive, although those of the largest molecular sizes appeared the most immunoreactive in this in vitro dot blot immunoassay. This method is very sensitive and specific to tuberculoproteins and can be an in vitro alternative for the in vivo intradermal skin assay which uses guinea pigs for identity of PPD preparations. Although the capacity of PPD to elicit cell-mediated immune responses on intradermal testing has to be confirmed by in vivo assay, the dot blot immunoassay offers a rapid, sensitive and animal-free alternative to in vivo testing for confirming the identity of PPD preparations with appropriate potencies. This alternative assay would be particularly useful for national regulatory laboratories for confirming the data of manufacturers and thus reducing the use of animals.
Code of Federal Regulations, 2012 CFR
2012-01-01
... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...
Alternative sample sizes for verification dose experiments and dose audits
NASA Astrophysics Data System (ADS)
Taylor, W. A.; Hansen, J. M.
1999-01-01
ISO 11137 (1995), "Sterilization of Health Care Products—Requirements for Validation and Routine Control—Radiation Sterilization", provides sampling plans for performing initial verification dose experiments and quarterly dose audits. Alternative sampling plans are presented which provide equivalent protection. These sampling plans can significantly reduce the cost of testing. These alternative sampling plans have been included in a draft ISO Technical Report (type 2). This paper examines the rational behind the proposed alternative sampling plans. The protection provided by the current verification and audit sampling plans is first examined. Then methods for identifying equivalent plans are highlighted. Finally, methods for comparing the cost associated with the different plans are provided. This paper includes additional guidance for selecting between the original and alternative sampling plans not included in the technical report.
Innovation and the Evolving System of U.S. Teacher Preparation
ERIC Educational Resources Information Center
Wilson, Suzanne M.
2014-01-01
A longstanding tradition criticizes education schools for their presumed vapid curriculum, out-of-touch faculty, irrelevance, and suffocating ideology. What is different at present is the enthusiasm for alternatives to university-based teacher preparation, as well as the increasing interest in holding teacher preparation programs accountable. I…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-21
... Fishery Management Council; Notice of Intent To Prepare an Environmental Impact Statement (EIS); Northeast... England Fishery Management Council (Council) announces its intention to prepare, in cooperation with NMFS... human environment of alternative measures to address management and conservation measures for the...
Photoluminescence and cathodoluminescence properties of green emitting SrGa2{S}4 : Eu2+ thin film
NASA Astrophysics Data System (ADS)
Chartier, Céline; Benalloul, Paul; Barthou, Charles; Frigerio, Jean-Marc; Mueller, Gerd O.; Mueller-Mach, Regina; Trottier, Troy
2002-02-01
Photoluminescence and cathodoluminescence properties of SrGa2S4 : Eu2+ thin films prepared by reactive RF magnetron sputtering are investigated. Luminescence performances of the phosphor in the thin film form are compared to those of powder samples: the brightness efficiency of thin films is found to be about 30% of the efficiency of powder at low current density. A ratio higher than 40% is expected at higher current density. Thin film screens for FEDs will become a positive alternative to powder screens provided that film quality and light extraction could be improved by optimization of thickness and deposition parameters.
Measurement of residual solvents in a drug substance by a purge-and-trap method.
Lakatos, Miklós
2008-08-05
The purge-and-trap (P&T) gas extraction method combined with gas chromatography was studied for its suitability for quantitative residual solvents determination in a water-soluble active pharmaceutical ingredient (API). Some analytical method performance characteristics were investigated, namely, the repeatability, the accuracy and the detection limit of determination. The results show that the P&T technique is--as expected--more sensitive than the static headspace, thus it can be used for the determination of residual solvents pertaining to the ICH Class 1 group. It was found that it could be an alternative sample preparation method besides the static headspace (HS) method.
Survival of Escherichia coli O157:H7 in ground beef jerky assessed on two plating media.
Harrison, J A; Harrison, M A; Rose, R A
1998-01-01
Recent outbreaks of food-borne illness due to Salmonella spp. in beef jerky and Escherichia coli O157:H7 in venison jerky, coupled with the fact that a variety of preparation methods and dying procedures abound, raise concern over the safety of processed meat products made in the home. The potential of injured bacterial cells to regain the ability to cause illness is a particular threat with pathogens such as E. coli O157:H7, which is believed to have a low infectious dose. This study examined the efficacy of various methods of jerky preparation in reducing populations of E, coli O157:H7 in ground beef jerky and compared the recovery rate of E. coli O157:H7 on two selective plating media, modified sorbitol MacConkey agar (MSMA) and modified eosin methylene blue agar (MEMB). Populations of E. coli O157:H7 in both heated and unheated samples exhibited a greater decline during drying when a nitrite and salt cure mix was added during jerky preparation. When recovery of E. coli O157:H7 on MSMA and MEMB was compared, a trend toward slightly higher recovery rates with MEMB was observed. On the basis of these results, MEMB is a suitable alternative to MSMA for the recovery of E. coli O157:H7 from heated and dried meat samples similar to beef jerky.
Research notes : September 1995.
DOT National Transportation Integrated Search
1995-09-01
The Repair of Rutting Caused by Studded Tires Literature Review was prepared to document the alternatives available for Oregon pavements. Other study objectives included determining the viability of the alternatives with regard to material costs (inc...
Test report : alternative fuels propulsion durability evaluation
DOT National Transportation Integrated Search
2012-08-28
This document, prepared by Honeywell Aerospace, Phoenix, AZ (Honeywell), contains the final : test report (public version) for the U.S. Department of Transportation/Federal Aviation : Administration (USDOT/FAA) Alternative Fuels Propulsion Engine Dur...
The Challenge of Educating Physicians about Complementary and Alternative Medicine.
ERIC Educational Resources Information Center
Konefal, Janet
2002-01-01
Asserts that most physicians are not prepared to respond knowledgeably about complementary/alternative medicine (CAM) modalities and suggests incorporating systematic presentation of CAM information into the curricula of medical schools. (EV)
NASA Astrophysics Data System (ADS)
Wirth, R.; Morales, L. G.
2011-12-01
Focused ion beam (FIB) techniques have been successfully applied to the preparation of site-specific electron transparent membranes for transmission electron microscopy (TEM) investigations in Geosciences since several years. For example, systematic TEM studies of nano-inclusions in diamond foils prepared with FIB have improved our knowledge on diamond formation. However, FIB is not exclusively used for sample preparation for TEM application because it has been proved that one and the same TEM foil can also be used for Synchrotron IR, Synchrotron X-Ray fluorescence (XRF), scanning transmission X-Ray microscopy (STXM) and NanoSIMS analysis. In addition, FIB milling turned out to be very useful for sample preparation of Brillouin scattering experiments and has a strong potential for preparation of highly-polished, micrometer-scale samples. However, a real break through in FIB application was achieved combining a Ga-ion source of the FIB with an electron source of a scanning electron microscope (SEM) in one single instrument. The combination of FIB/SEM renders access to the third dimension of the sample possible. A cavity normal to the sample surface is sputtered with Ga-ions and this newly created inner surface is imaged with the electron beam. Alternating slicing and viewing along these cavities allow the acquisition of a sequence of images that allows the observation in 3 dimensions. Recently, this technique has been successfully applied to image the structure of grain or phase boundaries in metamorphic rocks as well as micro- and nanoporosity in shales, but its applicability goes far beyond these few examples. Combining slicing and viewing with X-Ray and electron backscatter diffraction (EBSD) analysis can provide 3D elemental mapping and 3D crystallographic orientation mapping of crystalline materials. Combined FIB/SEM devices also facilitate the preparation of substantially thinner and cleaner TEM foils (approximately 30 nm) because electron beam imaging controls the progress of the sputtering process without sputtering the sample during imaging. Electron induce sputtering is substantially smaller than ion induced sputtering. Finally, the amorphous layers created by Ga-ion sputtering and Ga-ion implantation can be removed from the foil surfaces by subsequent argon ion bombardment under a low angle of incidence and low acceleration voltage thus permitting TEM high-resolution imaging and electron energy-loss spectroscopy (EELS). Additionally, ultra-thin foils have the advantage that they are electron transparent even at 30 keV, the common operational voltage of a SEM. Therefore the electron column of the FIB/SEM system can be used as a TEM at low voltage and images can be made either in bright-field, dark field and through a high-angle annular dark field (HAADF) detector. The HAADF detector provides information about the chemical composition of the specimen with high spatial resolution because it is Z-contrast sensitive.
Improved Dielectric Properties via Mechano-Chemical Activation in Ba0.80Pb0.20TiO3 Ceramics
NASA Astrophysics Data System (ADS)
Kumar, Parveen; Rani, Renu; Singh, Sangeeta; Juneja, J. K.; Prakash, Chandra; Raina, K. K.
2011-12-01
The present report is about the preparation and dielectric properties of commonly used Ba0.80Pb0.20TiO3 (BPT) ferroelectric ceramic via Mechano-Chemical Activation (MCA). Results were compared by the BPT sample prepared by conventional solid state method. The BPT sample prepared via MCA technique was found to have decreased tetragonality, dielectric constant value (ɛRT = 450 and ɛmax = 6170) approximately double the value for sample prepared by conventional method (ɛRT = 260 and ɛmax = 3275). Also, the sample prepared by MCA was found to be less frequency dependent. Thus, the BPT sample prepared via MCA is more suitable for capacitor applications requiring lesser frequency dependency than the conventionally prepared BPT sample.
2006-06-01
Preparation..........................................................................................................3 2.2 Alternatives Selection ...water-borne panels were green. 2.2 Alternatives Selection The Gap Assessment Report generated by CTC/NDCEE identified many HAP-free alternatives to...strip times (as reported by the vendor) of many of the products. ARL used this information to select the alternatives to be included in its test
Recent advances in applications of nanomaterials for sample preparation.
Xu, Linnan; Qi, Xiaoyue; Li, Xianjiang; Bai, Yu; Liu, Huwei
2016-01-01
Sample preparation is a key step for qualitative and quantitative analysis of trace analytes in complicated matrix. Along with the rapid development of nanotechnology in material science, numerous nanomaterials have been developed with particularly useful applications in analytical chemistry. Benefitting from their high specific areas, increased surface activities, and unprecedented physical/chemical properties, the potentials of nanomaterials for rapid and efficient sample preparation have been exploited extensively. In this review, recent progress of novel nanomaterials applied in sample preparation has been summarized and discussed. Both nanoparticles and nanoporous materials are evaluated for their unusual performance in sample preparation. Various compositions and functionalizations extended the applications of nanomaterials in sample preparations, and distinct size and shape selectivity was generated from the diversified pore structures of nanoporous materials. Such great variety make nanomaterials a kind of versatile tools in sample preparation for almost all categories of analytes. Copyright © 2015 Elsevier B.V. All rights reserved.
Chacaltana Mendoza, Alfonso; Rodríguez Ulloa, Carlos
2008-01-01
In search alternatives for colonoscopic preparation, we decided to compare the effectiveness, safety and tolerance of the use of 10% manitol with polyethyleneglycol. A prospective, randomized and simple blind study was performed. Eighty consecutive inpatients were prospectively randomized to receive bowel preparation for elective colonoscopy with either 1 liter of 10% manitol (M Group, n=40) or 4 liters of polyethyleneglycol (PEG Group, n=40). Criteria of evaluation were quality of preparation, pre and post preparation laboratory seric test (sodium, potassium, osmolarity) and the presence of undesirable side effects during the preparation. Both groups were comparable in age, sex and colonoscopic indications. There was no difference between both groups when evaluating the quality of preparation: good or excellent preparation of 87.5% (manitol Group) and 90% (PEG Group) (p=0.37). The frequency of adverse effects was minor in group manitol (30%) that in group PEG (42.5%), being the nausea the most frequent symptom in both groups. A slight increase in the levels of sodium, potassium and osmolarity serums was found in both groups, without statistical difference or clinical repercussion. The preparation for colon cleansing with 10% manitol is as effective and safe, but better tolerated and accepted than preparation with PEG. 10% manitol would be a good alternative for colonoscopic preparation, specially for diagnostic procedures.
Farzaneh, Amirfarrokh; DeJaco, Robert F.; Ohlin, Lindsay; ...
2017-08-02
A promising route for sustainable 1-butanol (butanol) production is ABE (acetone, butanol, ethanol) fermentation. However, recovery of the products is challenging because of the low concentrations obtained in the aqueous solution, thus hampering large-scale production of biobutanol. Membrane and adsorbent-based technologies using hydrophobic zeolites are interesting alternatives to traditional separation techniques (e.g., distillation) for energy-efficient separation of butanol from aqueous mixtures. To maximize the butanol over water selectivity of the material, it is important to reduce the number of hydrophilic adsorption sites. This can, for instance, be achieved by reducing the density of lattice defect sites where polar silanol groupsmore » are found. The density of silanol defects can be reduced by preparing the zeolite at neutral pH instead of using traditional synthesis solutions with high pH. In this work, binary adsorption of butanol and water in two silicalite-1 films was studied using in situ attenuated total reflectance–Fourier transform infrared (ATR-FTIR) spectroscopy under equal experimental conditions. One of the films was prepared in fluoride medium, whereas the other one was prepared at high pH using traditional synthesis conditions. The amounts of water and butanol adsorbed from binary vapor mixtures of varying composition were determined at 35 and 50 °C, and the corresponding adsorption selectivities were also obtained. Both samples showed very high selectivities (100–23 000) toward butanol under the conditions studied. The sample having low density of defects, in general, showed ca. a factor 10 times higher butanol selectivity than the sample having a higher density of defects at the same experimental conditions. This difference was due to a much lower adsorption of water in the sample with low density of internal defects. Analysis of molecular simulation trajectories provides insights on the local selectivities in the zeolite channel network and at the film surface.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farzaneh, Amirfarrokh; DeJaco, Robert F.; Ohlin, Lindsay
A promising route for sustainable 1-butanol (butanol) production is ABE (acetone, butanol, ethanol) fermentation. However, recovery of the products is challenging because of the low concentrations obtained in the aqueous solution, thus hampering large-scale production of biobutanol. Membrane and adsorbent-based technologies using hydrophobic zeolites are interesting alternatives to traditional separation techniques (e.g., distillation) for energy-efficient separation of butanol from aqueous mixtures. To maximize the butanol over water selectivity of the material, it is important to reduce the number of hydrophilic adsorption sites. This can, for instance, be achieved by reducing the density of lattice defect sites where polar silanol groupsmore » are found. The density of silanol defects can be reduced by preparing the zeolite at neutral pH instead of using traditional synthesis solutions with high pH. In this work, binary adsorption of butanol and water in two silicalite-1 films was studied using in situ attenuated total reflectance–Fourier transform infrared (ATR-FTIR) spectroscopy under equal experimental conditions. One of the films was prepared in fluoride medium, whereas the other one was prepared at high pH using traditional synthesis conditions. The amounts of water and butanol adsorbed from binary vapor mixtures of varying composition were determined at 35 and 50 °C, and the corresponding adsorption selectivities were also obtained. Both samples showed very high selectivities (100–23 000) toward butanol under the conditions studied. The sample having low density of defects, in general, showed ca. a factor 10 times higher butanol selectivity than the sample having a higher density of defects at the same experimental conditions. This difference was due to a much lower adsorption of water in the sample with low density of internal defects. Analysis of molecular simulation trajectories provides insights on the local selectivities in the zeolite channel network and at the film surface.« less
Guzmán-Larralde, Adriana J; Suaste-Dzul, Alba P; Gallou, Adrien; Peña-Carrillo, Kenzy I
2017-01-01
Because of the tiny size of microhymenoptera, successful morphological identification typically requires specific mounting protocols that require time, skills, and experience. Molecular taxonomic identification is an alternative, but many DNA extraction protocols call for maceration of the whole specimen, which is not compatible with preserving museum vouchers. Thus, non-destructive DNA isolation methods are attractive alternatives for obtaining DNA without damaging sample individuals. However, their performance needs to be assessed in microhymenopterans. We evaluated six non-destructive methods: (A) DNeasy® Blood & Tissue Kit; (B) DNeasy® Blood & Tissue Kit, modified; (C) Protocol with CaCl 2 buffer; (D) Protocol with CaCl 2 buffer, modified; (E) HotSHOT; and (F) Direct PCR. The performance of each DNA extraction method was tested across several microhymenopteran species by attempting to amplify the mitochondrial gene COI from insect specimens of varying ages: 1 day, 4 months, 3 years, 12 years, and 23 years. Methods B and D allowed COI amplification in all insects, while methods A, C, and E were successful in DNA amplification from insects up to 12 years old. Method F, the fastest, was useful in insects up to 4 months old. Finally, we adapted permanent slide preparation in Canada balsam for every technique. The results reported allow for combining morphological and molecular methodologies for taxonomic studies.
The Recent Developments in Sample Preparation for Mass Spectrometry-Based Metabolomics.
Gong, Zhi-Gang; Hu, Jing; Wu, Xi; Xu, Yong-Jiang
2017-07-04
Metabolomics is a critical member in systems biology. Although great progress has been achieved in metabolomics, there are still some problems in sample preparation, data processing and data interpretation. In this review, we intend to explore the roles, challenges and trends in sample preparation for mass spectrometry- (MS-) based metabolomics. The newly emerged sample preparation methods were also critically examined, including laser microdissection, in vivo sampling, dried blood spot, microwave, ultrasound and enzyme-assisted extraction, as well as microextraction techniques. Finally, we provide some conclusions and perspectives for sample preparation in MS-based metabolomics.
Alternative Energy Curriculum for Trade and Industry Exploratory. Final Report.
ERIC Educational Resources Information Center
University of Central Arkansas, Conway.
This study was a descriptive curriculum research project covering the development of learning packets on alternative energy. The purpose of the project was to improve instruction in trades and industry exploratory programs by providing alternative energy materials. It was anticipated that the use of a prepared learning package would facilitate the…
Alternate Methods of Effluent Disposal for On-Lot Home Sewage Systems. Special Circular 214.
ERIC Educational Resources Information Center
Wooding, N. Henry
This circular provides current information for homeowners who must repair or replace existing on-lot sewage disposal systems. Several alternatives such as elevated sand mounds, sand-lined beds and trenches and oversized absorption areas are discussed. Site characteristics and preparation are outlined. Each alternative is accompanied by a diagram…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-19
... associated with the construction and operation of the Glassboro-Camden Line (GCL) light rail system, as well as assess and document a No-Action Alternative and a Transportation System Management (TSM... and benefits of the GCL alternatives. Transportation System Management (TSM) Alternative: The TSM...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2013-03-01
This document is designed to assist covered fleets interested in taking advantage of more flexible compliance options and to facilitate the transition from Standard Compliance to Alternative Compliance. It is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-06-01
This document is designed to assist covered fleets interested in taking advantage of more flexible compliance options and to facilitate the transition from Standard Compliance to Alternative Compliance. It is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sears, Ted
2014-06-01
This document is designed to assist covered fleets interested in taking advantage of more flexible compliance options and to facilitate the transition from Standard Compliance to Alternative Compliance. It is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2010-11-01
This document is designed to assist covered fleets interested in taking advantage of more flexible compliance options and to facilitate the transition from Standard Compliance to Alternative Compliance. It is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.
I Only Wish I'd Known: Voices of Novice Alternatively Certified Special Education Teachers
ERIC Educational Resources Information Center
Casey, Pat; Dunlap, Karen; Brister, Heather; Davidson, Michele
2011-01-01
Increasing numbers of special education teachers enter the profession via widely varying preparation programs, also known as alternative certification programs. This article describes a survey of 54 novice special education teachers from alternative certification (AC) programs. In this paper, the authors discuss both challenges and support needs…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
... instrumentation to ensure adequate monitoring and to provide suitable baseline information. 2. Remediation Alternatives. The draft EIS will address an array of remediation alternatives that are necessary to prevent... benefits. The exact nature and extent of the remediation alternatives will be determined based on the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-05
... evaluation of the main dam's overall earthquake performance. 2. Remediation Alternatives. The draft EIS will address an array of remediation alternatives that are necessary to prevent loss of life, extensive... extent of the remediation alternatives will be determined based on the results of on- going geotechnical...
Alternate Route Teachers' Perceptions of Teaching Knowledge, Pre-Service Preparation and Mentoring
ERIC Educational Resources Information Center
Hines, Titus M.
2017-01-01
In recent years, school officials have observed that many of the novice, alternate route teachers hired into the educational staff of schools around the country have struggled with various aspects of the teaching profession, such as classroom management, implementation of classroom instruction and motivating students. Many times, alternate route…
Quantitative assessment of anthrax vaccine immunogenicity using the dried blood spot matrix.
Schiffer, Jarad M; Maniatis, Panagiotis; Garza, Ilana; Steward-Clark, Evelene; Korman, Lawrence T; Pittman, Phillip R; Mei, Joanne V; Quinn, Conrad P
2013-03-01
The collection, processing and transportation to a testing laboratory of large numbers of clinical samples during an emergency response situation present significant cost and logistical issues. Blood and serum are common clinical samples for diagnosis of disease. Serum preparation requires significant on-site equipment and facilities for immediate processing and cold storage, and significant costs for cold-chain transport to testing facilities. The dried blood spot (DBS) matrix offers an alternative to serum for rapid and efficient sample collection with fewer on-site equipment requirements and considerably lower storage and transport costs. We have developed and validated assay methods for using DBS in the quantitative anti-protective antigen IgG enzyme-linked immunosorbent assay (ELISA), one of the primary assays for assessing immunogenicity of anthrax vaccine and for confirmatory diagnosis of Bacillus anthracis infection in humans. We have also developed and validated high-throughput data analysis software to facilitate data handling for large clinical trials and emergency response. Published by Elsevier Ltd.
Practicable group testing method to evaluate weight/weight GMO content in maize grains.
Mano, Junichi; Yanaka, Yuka; Ikezu, Yoko; Onishi, Mari; Futo, Satoshi; Minegishi, Yasutaka; Ninomiya, Kenji; Yotsuyanagi, Yuichi; Spiegelhalter, Frank; Akiyama, Hiroshi; Teshima, Reiko; Hino, Akihiro; Naito, Shigehiro; Koiwa, Tomohiro; Takabatake, Reona; Furui, Satoshi; Kitta, Kazumi
2011-07-13
Because of the increasing use of maize hybrids with genetically modified (GM) stacked events, the established and commonly used bulk sample methods for PCR quantification of GM maize in non-GM maize are prone to overestimate the GM organism (GMO) content, compared to the actual weight/weight percentage of GM maize in the grain sample. As an alternative method, we designed and assessed a group testing strategy in which the GMO content is statistically evaluated based on qualitative analyses of multiple small pools, consisting of 20 maize kernels each. This approach enables the GMO content evaluation on a weight/weight basis, irrespective of the presence of stacked-event kernels. To enhance the method's user-friendliness in routine application, we devised an easy-to-use PCR-based qualitative analytical method comprising a sample preparation step in which 20 maize kernels are ground in a lysis buffer and a subsequent PCR assay in which the lysate is directly used as a DNA template. This method was validated in a multilaboratory collaborative trial.
Application of alternative fixatives to formalin in diagnostic pathology
Gatta, L. Benerini; Cadei, M.; Balzarini, P.; Castriciano, S.; Paroni, R.; Verzeletti, A.; Cortellini, V.; De Ferrari, F.; Grigolato, P.
2012-01-01
Fixation is a critical step in the preparation of tissues for histopathology. The aim of this study was to investigate the effects of different fixatives vs formalin on proteins and DNA, and to evaluate alternative fixation for morphological diagnosis and nucleic acid preservation for molecular methods. Forty tissues were fixed for 24 h with six different fixatives: the gold standard fixative formalin, the historical fixatives Bouin and Hollande, and the alternative fixatives Greenfix, UPM and CyMol. Tissues were stained (Haematoxylin-Eosin, Periodic Acid Schiff, Trichromic, Alcian-blue, High Iron Diamine stainings), and their antigenicity was determined by immunohistochemistry (performed with PAN-CK, CD31, Ki-67, S100, CD68, AML antibodies). DNA extraction, KRAS sequencing, FISH for CEP-17, and flow cytometry analysis of nuclear DNA content were applied. For cell morphology the alternative fixatives (Greenfix, UPM, CyMol) were equivalent to formalin. As expected, Hollande proved to be the best fixative for morphology. The morphology obtained with Bouin was comparable to the one with formalin. Hollande was the best fixative for histochemistry. Bouin proved to be equivalent to formalin. The alternative fixatives were equivalent to formalin, although with greater variability in haematoxylin-eosin staining. It proved the possibility to obtain immunohistochemical staining largely equivalent to that following formalin-fixation with the following fixatives: Greenfix, Hollande, UPM and CyMol. The tissues fixed in Bouin did not provide results comparable to those obtained with formalin. The DNA extracted from samples fixed with alternative fixatives was found to be suitable for molecular analysis. PMID:22688293
75 FR 39200 - Periodic Reporting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-08
... using an alternative sample frame. Establishing this docket will allow the Commission to consider the... Information System/Revenue Pieces and Weight (ODIS/RPW) data by 20 percent. Id. at 3. In effect, Proposal Two... sample size to a special study utilizing an alternative sample frame. The alternative sample frame that...
Vanadium phosphorus oxide (VPO) is a well-known catalyst used for the vapor phase n-butane oxidation to maleic anhydride. It is prepared by a variety of methods, all of which, however, eventually result in the same active phase. The two main methods for the preparation of its pr...
NASA Astrophysics Data System (ADS)
Tiecher, Tales; Caner, Laurent; Gomes Minella, Jean Paolo; Henrique Ciotti, Lucas; Antônio Bender, Marcos; dos Santos Rheinheimer, Danilo
2014-05-01
Conventional fingerprinting methods based on geochemical composition still require a time-consuming and critical preliminary sample preparation. Thus, fingerprinting characteristics that can be measured in a rapid and cheap way requiring a minimal sample preparation, such as spectroscopy methods, should be used. The present study aimed to evaluate the sediment sources contribution in a rural catchment by using conventional method based on geochemical composition and on an alternative method based on near-infrared spectroscopy. This study was carried out in a rural catchment with an area of 1,19 km2 located in southern Brazil. The sediment sources evaluated were crop fields (n=20), unpaved roads (n=10) and stream channels (n=10). Thirty suspended sediment samples were collected from eight significant storm runoff events between 2009 and 2011. Sources and sediment samples were dried at 50oC and sieved at 63 µm. The total concentration of Ag, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, La, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sr, Ti, Tl, V and Zn were estimated by ICP-OES after microwave assisted digestion with concentrated HNO3 and HCl. Total organic carbon (TOC) was estimated by wet oxidation with K2Cr2O7 and H2SO4. The near-infrared spectra scan range was 4000 to 10000 cm-1 at a resolution of 2 cm-1, with 100 co added scans per spectrum. The steps used in the conventional method were: i) tracer selection based on Kruskal-Wallis test, ii) selection of the best set of tracers using discriminant analyses and finally iii) the use of a mixed linear model to calculate the sediment sources contribution. The steps used in the alternative method were i) principal component analyses to reduce the number of variables, ii) discriminant analyses to determine the tracer potential of the near-infrared spectroscopy, and finally iii) the use of past least square based on 48 mixtures of the sediment sources in various weight proportions to calculate the sediment sources contribution. Both conventional and alternative methods were capable to discriminate 100% of the sediment sources. Conventional fingerprinting method provided a sediment sources contribution of 33±19% by crop fields, 25±13% by unpaved roads and 42±19% by stream channels. The contribution of sediment sources obtained by alternative fingerprinting method using near-infrared spectroscopy was 71±22% of crop fields, 21±12% of unpaved roads and 14±19% of stream channels. No correlation was observed between source contribution assessed by the two methods. Notwithstanding, the average contribution of the unpaved roads was similar by both methods. The highest difference in the average contribution of crop fields and stream channels estimated by the two methods was due to similar organic matter content of these two sediment sources which hampers their discrimination by assessing the near-infrared spectra, where much of the bands are highly correlated with the TOC levels. Efforts should be taken to try to combine both the geochemical composition and near-infrared spectroscopy information on a single estimative of the sediment sources contribution.
Transforming Teacher Preparation to Ensure Long-Term Improvement in STEM Teaching
ERIC Educational Resources Information Center
Hiebert, James
2013-01-01
An alternative mathematics preparation program for K-8 teachers is described as an existence proof that steadily increasing effectiveness of STEM (science, technology, engineering, and mathematics) preparation is possible. The program is based on treating every lesson in each of five mathematics content and methods courses as objects of study.…
ERIC Educational Resources Information Center
Smith, Rachel A.; Somers, John
2016-01-01
This paper presents a model for developing an interdisciplinary principal preparation program, an MBA in Education Leadership, which integrates best practices in both education and business within an educational context. The paper addresses gaps that exist in many traditional principal preparation programs and provides an alternative model, which…
Mandal, Abhishek; Boatz, Jennifer C.; Wheeler, Travis; van der Wel, Patrick C. A.
2017-01-01
A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation. PMID:28229262
Haglund, Jr., Richard F.; Ermer, David R.; Baltz-Knorr, Michelle Lee
2004-11-30
A system and method for desorption and ionization of analytes in an ablation medium. In one embodiment, the method includes the steps of preparing a sample having analytes in a medium including at least one component, freezing the sample at a sufficiently low temperature so that at least part of the sample has a phase transition, and irradiating the frozen sample with short-pulse radiation to cause medium ablation and desorption and ionization of the analytes. The method further includes the steps of selecting a resonant vibrational mode of at least one component of the medium and selecting an energy source tuned to emit radiation substantially at the wavelength of the selected resonant vibrational mode. The medium is an electrophoresis medium having polyacrylamide. In one embodiment, the energy source is a laser, where the laser can be a free electron laser tunable to generate short-pulse radiation. Alternatively, the laser can be a solid state laser tunable to generate short-pulse radiation. The laser can emit light at various ranges of wavelength.
Kovatsi, Leda; Rentifis, Konstantinos; Giannakis, Dimitrios; Njau, Samuel; Samanidou, Victoria
2011-07-01
The availability of a sensitive and rapid analytical method for the determination of opiates, and other substances of forensic interest, in a variety of biological specimens is of utmost importance to forensic laboratories. Solid-phase extraction is very popular in the pre-treatment of forensic samples. Nevertheless, a new approach, disposable pipette extraction (DPX), is gaining increasing interest in sample preparation. DPX has already been applied to the analysis of drugs of abuse in common biological matrices, such as urine and blood, but has not yet been evaluated on alternative biological samples, such as vitreous humor. The objective of this study was to evaluate the applicability of DPX on the analysis of opiates in vitreous humor. The currently developed method is fast, reliable, and easy to perform. The sensitivity, precision, and accuracy are satisfactory. Recoveries obtained are within the range of 72-91%, whereas the sample volume of vitreous humor required is only 100 μL. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Enabling environmental metagenomics and extremophile discovery through SCODA DNA purification
NASA Astrophysics Data System (ADS)
Lum, T.; Maydan, J.
2016-12-01
A major challenge in nucleic acid preparation from environmental samples is in the ability to separate DNA and RNA from contaminants that often co-purify with methods commonly used. This becomes even more challenging when nucleic acids are in low abundance or when enriching for high molecular weight fragments. Many column- and bead-based methods rely upon selective chemical affinity which is insufficient in dealing with similarly charged contaminants, and also often result in over fragmentation nucleic acids and substantial sample loss. Here we present a unique and alternative parameter for the separation nucleic acids based on the nonlinear response of long, charged polymers to electrophoretic fields. The synchronous coefficient of drag alteration (SCODA) technology is capable of purifying nucleic acids from highly contaminated sample matrices, with molecular weight ranges from 300 bp to over 1 Mbp, and from very low biomass origins. Using a combination of rotating dipole and quadrupole electric fields, SCODA technology concentrates ultrapure nucleic acids that enable PCR, NGS, and optical mapping applications on sample types that are otherwise difficult or impossible to analyze.
NASA Astrophysics Data System (ADS)
Tumey, Scott J.; Brown, Thomas A.; Hamilton, Terry E.; Hillegonds, Darren J.
2008-05-01
Strontium-90 is one of the most hazardous materials managed by agencies charged with protecting the public from radiation. Traditional radiometric methods have been limited by low sample throughput and slow turnaround times. Mass spectrometry offers the advantage of shorter analysis times and the ability to measure samples immediately after processing, however conventional mass spectrometric techniques are susceptible to molecular isobaric interferences that limit their overall sensitivity. In contrast, accelerator mass spectrometry is insensitive to molecular interferences and we have therefore begun developing a method for determination of 90Sr by accelerator mass spectrometry. Despite a pervasive interference from 90Zr, our initial development has yielded an instrumental background of ∼108 atoms (75 mBq) per sample. Further refinement of our system (e.g. redesign of our detector, use of alternative target materials) is expected to push the background below 106 atoms, close to the theoretical limit for AMS. Once we have refined our system and developed suitable sample preparation protocols, we will utilize our capability in applications to homeland security, environmental monitoring and human health.
Han, Yanxi; Li, Jinming
2017-10-26
In this era of precision medicine, molecular biology is becoming increasingly significant for the diagnosis and therapeutic management of non-small cell lung cancer. The specimen as the primary element of the whole testing flow is particularly important for maintaining the accuracy of gene alteration testing. Presently, the main sample types applied in routine diagnosis are tissue and cytology biopsies. Liquid biopsies are considered as the most promising alternatives when tissue and cytology samples are not available. Each sample type possesses its own strengths and weaknesses, pertaining to the disparity of sampling, preparation and preservation procedures, the heterogeneity of inter- or intratumors, the tumor cellularity (percentage and number of tumor cells) of specimens, etc., and none of them can individually be a "one size to fit all". Therefore, in this review, we summarized the strengths and weaknesses of different sample types that are widely used in clinical practice, offered solutions to reduce the negative impact of the samples and proposed an optimized strategy for choice of samples during the entire diagnostic course. We hope to provide valuable information to laboratories for choosing optimal clinical specimens to achieve comprehensive functional genomic landscapes and formulate individually tailored treatment plans for NSCLC patients that are in advanced stages.
Drabova, Lucie; Pulkrabova, Jana; Kalachova, Kamila; Tomaniova, Monika; Kocourek, Vladimir; Hajslova, Jana
2012-10-15
A simple, fast, and cost effective sample preparation procedure has been developed and validated for the determination of 15+1 European Union Polycyclic Aromatic Hydrocarbons (15+1 EU PAHs) in dried tea leave samples. Based on a critical assessment of several sample extraction/clean-up approaches, the method based on the ethyl acetate extraction followed by the use of PAHs dedicated cartridges with molecularly imprinted polymers (MIPs) has been found as an optimal alternative in terms of time demands and obtained good extract purity. For the final identification/quantification of target PAHs, two dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC×GC-TOFMS) was used. The performance characteristics of the overall analytical method for individual PAHs determined at three spiking levels (0.5, 2.5 and 5 μg kg(-1)) were in following ranges: limits of quantitation (LOQs) 0.05-0.2 μg kg(-1), repeatabilities 2-9%, and recoveries 73-103%. The recoveries achieved by the newly developed sample preparation procedure when employed for naturally contaminated sample ("incurred" PAHs) were comparable to those obtained by other routinely used approaches employing sonication and/or pressurised liquid extraction for sample analytes isolation. The validated method was subsequently used for the determination of selected genotoxic PAHs in 36 samples of black and green tea obtained from the Czech retail market. The levels of ΣPAH4 (sum of benzo[a]anthracene (BaA), chrysene (CHR), benzo[b]fluoranthene (BbFA) and benzo[a]pyrene (BaP)) in black and green tea leaves ranged from 7.4 to 700 μg kg(-1) and from 4.5 to 102 μg kg(-1), respectively. Contamination of tested tea samples by BaP was in the range of 0.2-152 μg kg(-1). Copyright © 2012 Elsevier B.V. All rights reserved.
Joyce, Richard; Kuziene, Viktorija; Zou, Xin; Wang, Xueting; Pullen, Frank; Loo, Ruey Leng
2016-01-01
An ultra-performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-qTOF-MS) method using hydrophilic interaction liquid chromatography was developed and validated for simultaneous quantification of 18 free amino acids in urine with a total acquisition time including the column re-equilibration of less than 18 min per sample. This method involves simple sample preparation steps which consisted of 15 times dilution with acetonitrile to give a final composition of 25 % aqueous and 75 % acetonitrile without the need of any derivatization. The dynamic range for our calibration curve is approximately two orders of magnitude (120-fold from the lowest calibration curve point) with good linearity (r (2) ≥ 0.995 for all amino acids). Good separation of all amino acids as well as good intra- and inter-day accuracy (<15 %) and precision (<15 %) were observed using three quality control samples at a concentration of low, medium and high range of the calibration curve. The limits of detection (LOD) and lower limit of quantification of our method were ranging from approximately 1-300 nM and 0.01-0.5 µM, respectively. The stability of amino acids in the prepared urine samples was found to be stable for 72 h at 4 °C, after one freeze thaw cycle and for up to 4 weeks at -80 °C. We have applied this method to quantify the content of 18 free amino acids in 646 urine samples from a dietary intervention study. We were able to quantify all 18 free amino acids in these urine samples, if they were present at a level above the LOD. We found our method to be reproducible (accuracy and precision were typically <10 % for QCL, QCM and QCH) and the relatively high sample throughput nature of this method potentially makes it a suitable alternative for the analysis of urine samples in clinical setting.
A new approach to preparation of standard LEDs for luminous intensity and flux measurement of LEDs
NASA Astrophysics Data System (ADS)
Park, Seung-Nam; Park, Seongchong; Lee, Dong-Hoon
2006-09-01
This work presents an alternative approach for preparing photometric standard LEDs, which is based on a novel functional seasoning method. The main idea of our seasoning method is simultaneously monitoring the light output and the junction voltage to obtain quantitative information on the temperature dependence and the aging effect of the LED emission. We suggested a general model describing the seasoning process by taking junction temperature variation and aging effect into account and implemented a fully automated seasoning facility, which is capable of seasoning 12 LEDs at the same time. By independent measurements of the temperature dependence, we confirmed the discrepancy of the theoretical model to be less than 0.5 % and evaluate the uncertainty contribution of the functional seasoning to be less than 0.5 % for all the seasoned samples. To demonstrate assigning the reference value to a standard LED, the CIE averaged LED intensity (ALI) of the seasoned LEDs was measured with a spectroradiometer-based instrument and the measurement uncertainty was analyzed. The expanded uncertainty of the standard LED prepared by the new approach amounts to be 4 % ~ 5 % (k=2) depending on color without correction of spectral stray light in the spectroradiometer.
2012-01-01
Background Malaria caused by Plasmodium falciparum infects roughly 30,000 individuals in Haiti each year. Haiti has used chloroquine (CQ) as a first-line treatment for malaria for many years and as a result there are concerns that malaria parasites may develop resistance to CQ over time. Therefore it is important to prepare for alternative malaria treatment options should CQ resistance develop. In many other malaria-endemic regions, antifolates, particularly pyrimethamine (PYR) and sulphadoxine (SDX) treatment combination (SP), have been used as an alternative when CQ resistance has developed. This study evaluated mutations in the dihydrofolate reductase (dhfr) and dihydropteroate synthetase (dhps) genes that confer PYR and SDX resistance, respectively, in P. falciparum to provide baseline data in Haiti. This study is the first comprehensive study to examine PYR and SDX resistance genotypes in P. falciparum in Haiti. Methods DNA was extracted from dried blood spots and genotyped for PYR and SDX resistance mutations in P. falciparum using PCR and DNA sequencing methods. Sixty-one samples were genotyped for PYR resistance in codons 51, 59, 108 and 164 of the dhfr gene and 58 samples were genotyped for SDX resistance codons 436, 437, 540 of the dhps gene in P. falciparum. Results Thirty-three percent (20/61) of the samples carried a mutation at codon 108 (S108N) of the dhfr gene. No mutations in dhfr at codons 51, 59, 164 were observed in any of the samples. In addition, no mutations were observed in dhps at the three codons (436, 437, 540) examined. No significant difference was observed between samples collected in urban vs rural sites (Welch’s T-test p-value = 0.53 and permutations p-value = 0.59). Conclusion This study has shown the presence of the S108N mutation in P. falciparum that confers low-level PYR resistance in Haiti. However, the absence of SDX resistance mutations suggests that SP resistance may not be present in Haiti. These results have important implications for ongoing discussions on alternative malaria treatment options in Haiti. PMID:22889367
Asimakopoulos, Alexandros G; Kannan, Pranav; Higgins, Sean; Kannan, Kurunthachalam
2017-10-01
A liquid chromatography-triple quadrupole-tandem mass spectrometry (LC-qQq-MS/MS) method was developed for simultaneous determination of 89 legal neuropsychiatric pharmaceuticals and illicit drugs (both parent compounds and metabolites) and other micropollutants in unfiltered wastewater and freshwater. The target chemicals fall under the classes of amphetamine-type stimulants, cocaine compounds, opiates and opioids, benzodiazepines, lysergic compounds, antipsychotics, anesthetics, antiepileptics, antidepressants, sympathomimetics, cannabinoids, blood thinners, antihistamines, β-blockers, caffeine derivatives, nicotine derivatives, z-drugs, new designer drugs, and Alzheimer medications. The sample preparation procedure was designed for unfiltered wastewater and freshwater without the need to separate the particulate matter (if any) from the aqueous phase prior to extraction. Samples were pre-concentrated by rotary evaporation in the presence of a solvent. Method precision (absolute values; N = 6 replicate analyses at the fortification level of 50 ng, k = 6 days) for 87 out of 89 target analytes ranged from 2.8 to 34% (RSD %). The limits of detection ranged from 0.11 to 202 ng L -1 , and the matrix effects ranged from +16 to -84%. A total of 10 samples, 8 wastewater, 1 drinking water, and 1 lake water, were collected from New York State, USA, and were analyzed for the target compounds to demonstrate the applicability of the developed method. This is the first study to report the analysis of multiple classes of pharmaceuticals, illicit drugs, and other micropollutants in unfiltered wastewater. Graphical abstract Analysis of 89 micropollutants in unfiltered wastewater by LC-MS/MS.
Jiang, Li; Huang, Tengjun; Feng, Shun; Wang, Jide
2016-07-22
The widespread use of organophosphate pesticides (OPPs) in agriculture leads to residue accumulation in the environment which is dangerous to human health and disrupts the ecological balance. In this work, one nanocomposite immobilized zirconium (Zr, IV) was prepared and used as the affinity probes to quickly and selectively extract organophosphorus pesticides (OPPs) from water samples. The Fe3O4-ethylenediamine tetraacetic acid (EDTA)@Zr(IV) nanocomposites (NPs) were prepared by simply mixing Zr(IV) ions with Fe3O4-EDTA NPs synthesized by one-pot chemical co-precipitation method. The immobilized Zr(IV) ions were further utilized to capture OPPs based on their high affinity for the phosphate moiety in OPPs. Coupled with GC-MS, four OPPs were used as models to demonstrate the feasibility of this approach. Under the optimum conditions, the limits of detection for target OPPs were in the range of 0.10-10.30ngmL(-1) with relative standard deviations (RSDs) of 0.61-4.40% (n=3), respectively. The linear ranges were over three orders of magnitudes (correlation coefficients, R(2)>0.9995). The Fe3O4-EDTA@Zr(IV) NPs were successfully applied to extract OPPs samples with recoveries of 86.95-112.60% and RSDs of 1.20-10.42% (n=3) from two spiked real water. By the proposed method, the matrix interference could be effectively eliminated. We hope our finding can provide a promising alternative for the fast extraction of OPPs from complex real samples. Copyright © 2016 Elsevier B.V. All rights reserved.
2013-01-01
In this study a composite of activated carbon and carbon nanofiber (AC/CNF) was prepared to improve the performance of activated carbon (AC) for adsorption of volatile organic compounds (VOCs) and its utilization for respirator cartridges. Activated carbon was impregnated with a nickel nitrate catalyst precursor and carbon nanofibers (CNF) were deposited directly on the AC surface using catalytic chemical vapor deposition. Deposited CNFs on catalyst particles in AC micropores, were activated by CO2 to recover the surface area and micropores. Surface and textural characterizations of the prepared composites were investigated using Brunauer, Emmett and Teller’s (BET) technique and electron microscopy respectively. Prepared composite adsorbent was tested for benzene, toluene and xylene (BTX) adsorption and then employed in an organic respirator cartridge in granular form. Adsorption studies were conducted by passing air samples through the adsorbents in a glass column at an adjustable flow rate. Finally, any adsorbed species not retained by the adsorbents in the column were trapped in a charcoal sorbent tube and analyzed by gas chromatography. CNFs with a very thin diameter of about 10-20 nm were formed uniformly on the AC/CNF. The breakthrough time for cartridges prepared with CO2 activated AC/CNF was 117 minutes which are significantly longer than for those cartridges prepared with walnut shell- based activated carbon with the same weight of adsorbents. This study showed that a granular form CO2 activated AC/CNF composite could be a very effective alternate adsorbent for respirator cartridges due to its larger adsorption capacities and lower weight. PMID:23369424
ERIC Educational Resources Information Center
Hogan, Kathleen Ann
2010-01-01
This study was developed to examine the motivations of individuals who chose alternative routes to teacher certification and what they believe were the strengths and weaknesses of their alternative certification preparation (ACP). Data accrued from this study were based on a 55-item online survey and participant information from an online focus…
ERIC Educational Resources Information Center
Darling-Hammond, Linda
2009-01-01
Recent findings from a Mathematica study comparing the performance of teachers prepared via alternative and traditional routes have been interpreted to suggest that policymakers and practitioners should expand the use of fast-entry alternative routes and seek teachers trained through such programs, as they presumably perform as well in the…
NASA Astrophysics Data System (ADS)
Chioma Affam, Augustine; Chung Wong, Chee; Seyam, Mohammed A. B.; Matt, Chelsea Ann Anak Frederick; Lantan Anak Sumbai, Josephine; Evuti, Abdullahi Mohammed
2018-03-01
Boron and organics maybe in high concentration during production of oil and gas, fertilizers, glass, and detergents. In addition, boron added to these industrial processes may require to be removed by the wastewater treatment plant. The preparation, characterization and application of iron oxide-activated carbon composite for removal of boron and COD was studied. The one variable at a time (OVAT) method was implemented to obtain desirable operating conditions (adsorbent dosage 5 g/L, reaction time 2 h, agitation speed 100 rpm, pH 5 for COD removal and pH 9 for boron removal). It was found that boron and organics present in a sample wastewater may require to be treated separately to remove the contaminants. The study achieved 97 and 70% for boron and COD removal, respectively. Adsorption as an alternative cheap source of treatment and its practicability for small communities is recommended as effective in removal of contaminants from river water.
NASA Astrophysics Data System (ADS)
Lv, Chao; Yang, Kun; Wen, Shu-ming; Bai, Shao-jun; Feng, Qi-cheng
2017-10-01
This paper proposes a new technique for preparation of high-grade titanium slag from Panzhihua vanadium titanomagnetite concentrate by reduction-melting-magnetic separation processing. Chemical analysis, x-ray diffraction, and scanning electron microscopy in conjunction with energy-dispersive spectroscopy were used to characterize the samples. The effective separation of iron and titanium slag could be realized by melting metallized pellets at 1550°C for 60 min with the addition of 1% CaO (basicity of 1.1) and 2% graphite powder. The small iron particles embedded in the slag could be removed by fine grinding and magnetic separation process. The grade of TiO2 in the obtained high-grade titanium slag reached 60.68% and the total recovery of TiO2 was 91.25%, which could be directly applied for producing titanium white by the sulfuric acid process. This technique provides an alternative method to use vanadium titanomagnetite concentrate of the Panzhihua area in China.
Immunoanalysis Methods for the Detection of Dioxins and Related Chemicals
Tian, Wenjing; Xie, Heidi Qunhui; Fu, Hualing; Pei, Xinhui; Zhao, Bin
2012-01-01
With the development of biotechnology, approaches based on antibodies, such as enzyme-linked immunosorbent assay (ELISA), active aryl hydrocarbon immunoassay (Ah-I) and other multi-analyte immunoassays, have been utilized as alternatives to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of dioxin and dioxin-like compounds in environmental and biological samples. These screening methods have been verified as rapid, simple and cost-effective. This paper provides an overview on the development and application of antibody-based approaches, such as ELISA, Ah-I, and multi-analyte immunoassays, covering the sample extraction and cleanup, antigen design, antibody preparation and immunoanalysis. However, in order to meet the requirements for on-site fast detection and relative quantification of dioxins in the environment, further optimization is needed to make these immuno-analytical methods more sensitive and easy to use. PMID:23443395
Di Giuseppe, Antonella M A; Giarretta, Nicola; Lippert, Martina; Severino, Valeria; Di Maro, Antimo
2015-02-15
In 2013, following the scandal of the presence of undeclared horse meat in various processed beef products across the Europe, several researches have been undertaken for the safety of consumer health. In this framework, an improved UPLC separation method has been developed to detect the presence of horse myoglobin in raw meat samples. The separation of both horse and beef myoglobins was achieved in only seven minutes. The methodology was improved by preparing mixtures with different composition percentages of horse and beef meat. By using myoglobin as marker, low amounts (0.50mg/0.50g, w/w; ∼0.1%) of horse meat can be detected and quantified in minced raw meat samples with high reproducibility and sensitivity, thus offering a valid alternative to conventional PCR techniques. Copyright © 2014 Elsevier Ltd. All rights reserved.
The equilibrium sedimentation of hyaluronic acid and of two synthetic polymers
Nichol, L. W.; Ogston, A. G.; Preston, B. N.
1967-01-01
1. The method of equilibrium sedimentation has been investigated as an alternative to osmotic-pressure measurement for determining thermodynamic properties of polymer solutions at relatively high concentrations. 2. The simplifications that must be made in the theoretical treatment are discussed. 3. Measurements have been made on samples of polyethylene glycol, neutralized polymethacrylic acid and hyaluronic acid. With the first and third, values of the `non-ideality coefficients' have been obtained that agree with those obtained from osmotic measurements on the same materials. 4. Evidence has been obtained of the presence in hyaluronic acid preparations of a fraction that has either a lower degree of thermodynamic non-ideality or a higher density increment than the bulk of the sample. This fraction is not protein. ImagesFig. 3.Fig. 4.Fig. 5.Fig. 7.Fig. 8.Fig. 9.Fig. 11.Fig. 12.Fig. 13.Fig. 14. PMID:6029600
de Jonge, Martin D.; Ryan, Christopher G.; Jacobsen, Chris J.
2014-01-01
X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer. PMID:25177992
Multilayer porous structures of HVPE and MOCVD grown GaN for photonic applications
NASA Astrophysics Data System (ADS)
Braniste, T.; Ciers, Joachim; Monaico, Ed.; Martin, D.; Carlin, J.-F.; Ursaki, V. V.; Sergentu, V. V.; Tiginyanu, I. M.; Grandjean, N.
2017-02-01
In this paper we report on a comparative study of electrochemical processes for the preparation of multilayer porous structures in hydride vapor phase epitaxy (HVPE) and metal organic chemical vapor phase deposition (MOCVD) grown GaN. It was found that in HVPE-grown GaN, multilayer porous structures are obtained due to self-organization processes leading to a fine modulation of doping during the crystal growth. However, these processes are not totally under control. Multilayer porous structures with a controlled design have been produced by optimizing the technological process of electrochemical etching in MOCVD-grown samples, consisting of five pairs of thin layers with alternating-doping profiles. The samples have been characterized by SEM imaging, photoluminescence spectroscopy, and micro-reflectivity measurements, accompanied by transfer matrix analysis and simulations by a method developed for the calculation of optical reflection spectra. We demonstrate the applicability of the produced structures for the design of Bragg reflectors.
Standardized Sample Preparation Using a Drop-on-Demand Printing Platform
2013-05-07
successful and robust methodology for energetic sample preparation. Keywords: drop-on-demand; inkjet printing; sample preparation OPEN ACCESS...on a similar length scale. Recently, drop-on-demand inkjet printing technology has emerged as an effective approach to produce test materials to...which most of the material is concentrated along the edges, samples prepared using drop-on-demand inkjet technology demonstrate excellent uniform
NASA Astrophysics Data System (ADS)
Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi
2014-06-01
Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.
NASA Astrophysics Data System (ADS)
Kılıç, Murat; Apaydın-Varol, Esin; Pütün, Ayşe Eren
2012-11-01
Preparation of activated carbons from Euphorbia rigida by chemical activation with different impregnation agents and ratios was studied. ZnCl2, K2CO3, NaOH and H3PO4 were used as chemical activation agents and four impregnation ratios (25-50-75-100%) by mass were applied on biomass. Activation is applied to impregnated biomass samples at 700 °C under sweeping gas in a fixed bed reactor. For determination of chemical and physical properties of the obtained activated carbons; elemental analysis was applied to determine the elemental composition (C, H, N, O) and FT-IR spectra was used to analyze the functional groups. BET equation was used to calculate the surface areas of activated carbons. For understanding the changes in the surface structure, activated carbons were conducted to Scanning Electron Microscopy (SEM). Maximum BET surface area (2613 m2/g) was reached with 75% K2CO3 impregnated biomass sample. Experimental results showed that impregnation types and ratios have a significant effect on the pore structure of activated carbon and E. rigida seems to be an alternative precursor for commercial activated carbon production.
Xu, Chen; Yu, Yingjia; Ling, Li; Wang, Yang; Zhang, Jundong; Li, Yan; Duan, Gengli
2017-01-01
A rapid, effective extraction technique has been established for measuring the gallic acid in rat plasma by using sandwich-structured graphene/mesoporous silica composites with C 8 -modified interior pore-walls as adsorbent. The unique characteristics of the graphene-silica composites excluded large molecules, like proteins, from the mesopore channels as a result of size exclusion effect, leading to a direct extraction of drug molecules from protein-rich biological samples such as plasma without any other pretreatment procedure. Followed by elution and centrifugation, the gallic acid-absorbed composites were rapidly isolated before LC-MS/MS. Serving as a reliable tool for analysis of Traditional Chinese Medicine: Changtai Granule, the newly developed method was fully validated and successfully applied in the pharmacokinetic study of gallic acid in rat plasma. Extraction recovery, matrix effect and stability were satisfactory in rat plasma. According to the results of pharmacokinetic studies, Changtai Granule exhibited greater adsorption, distribution and clearance properties of gallic acid in the treatment of ulcerative colitis. Hence, this study may offer a valuable alternative to simplify and speed up sample preparation, and be useful for clinical studies of related preparations.
ERIC Educational Resources Information Center
Melaku, Samuel; Dabke, Rajeev B.
2014-01-01
A guide for instructors and laboratory assistants to prepare some common aqueous reagents used in an undergraduate laboratory is presented. Dilute reagents consisting of H[superscript +](aq), I[subscript 3][superscript-](aq), Ce[superscript 4+](aq), and Ag[superscript+](aq) were prepared by electrolytic oxidation of respective precursors.…
Watson-Leung, Trudy; Graham, Matt; Hartman, Erin; Welsh, Paul G
2017-01-01
Potential adverse impacts to the aquatic environment should be minimized whenever possible during an environmental dredging project by selecting realistic and technically feasible environmental targets. These targets need to balance short term impacts with the longer term benefit of removing contaminated sediments from the environment. Environmental dredging is part of the planned remediation of Randle Reef (a 60 hectare zone of mostly PAH-contaminated sediments) in Hamilton, Ontario, Canada. In this study, we describe the results of dredging elutriate toxicity testing (DETE) to assess the potential risks from dredging this PAH contaminated site. A modified elutriate preparation method intended as an alternative measure of conditions within the dredging plume was assessed with both standard water column species (Daphnia magna and fathead minnow [Pimephales promelas]) and alternative benthic and epibenthic test organisms (Chironomus dilutus and Hyalella azteca). The standard DETE test was also conducted with H. azteca to compare with the modified DETE results. The greatest toxic response was seen in the alternative test species; however, the modified DETE method resulted in less toxicity than the standard protocol. The relationship between toxicity results and chemical and/or physical characteristics of the samples was examined, but differences in toxicity could only be explained by differences in the total suspended solids concentrations in the elutriate samples. Challenges associated with DETE assessment of PAH-contaminated sediments and the implications for establishing dredging benchmarks are discussed. Integr Environ Assess Manag 2017;13:155-166. © 2016 SETAC. © 2016 SETAC.
USDA-ARS?s Scientific Manuscript database
Biodiesel is a renewable alternative to petrodiesel that is prepared from plant oils or animal fats. Biodiesel is prepared via transesterification and the resulting fuel properties must be compliant with international fuel standards such as ASTM D6751 and EN 14214. Numerous catalysts, methods, and l...
Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas
2014-12-02
Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.
Stability of Extemporaneously Prepared Hydroxycarbamide Oral Suspensions.
Kabiche, Djamila; Balde, Issa-Bella; Majoul, Elyes; Kabiche, Sofiane; Bourguignon, Elodie; Fontan, Jean-Eudes; Cisternino, Salvatore; Schlatter, Jöel
2017-01-01
Hydroxycarbamide, available as tablets, is a pharmacological agent for fetal hemoglobin induction such as sickle cell anemia. The need for alternative dosage form options for patients unable to take tablets led hospital pharmacies to prepare solutions and suspensions. The objective of this study was to determine the stability of hydroxycarbamide in Ora-Plus in combination with either Ora-Sweet or Ora-Sweet SF, Ora-Blend, or Ora-Blend SF suspending agents. The studied samples were compounded into 100-mg/mL suspensions and stored in 60-mL amber glass bottles at room (22°C to 25°C) or refrigerated (4°C to 8°C) temperature. Samples were assayed at each time point out to 120 days by a stability-indicating high-performance liquid chromatography method. The samples were examined for any change in color, odor, visual microbiology, and pH on initial and final day of analysis. At least 90% of hydroxycarbamide concentration remained in all suspensions at the end of the 120-day study period in both conditions. There was no appreciable change in color, odor, or taste. The pH values of suspensions stored at 25°C changed by at least 1 unit at the end of the study period. Based on the data collected, the beyond-use date of these suspensions is 120 days when stored in 60-mL amber glass bottles at both temperature storage conditions. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Rettig, Trisha A; Ward, Claire; Pecaut, Michael J; Chapes, Stephen K
2017-07-01
Spaceflight is known to affect immune cell populations. In particular, splenic B cell numbers decrease during spaceflight and in ground-based physiological models. Although antibody isotype changes have been assessed during and after space flight, an extensive characterization of the impact of spaceflight on antibody composition has not been conducted in mice. Next Generation Sequencing and bioinformatic tools are now available to assess antibody repertoires. We can now identify immunoglobulin gene- segment usage, junctional regions, and modifications that contribute to specificity and diversity. Due to limitations on the International Space Station, alternate sample collection and storage methods must be employed. Our group compared Illumina MiSeq sequencing data from multiple sample preparation methods in normal C57Bl/6J mice to validate that sample preparation and storage would not bias the outcome of antibody repertoire characterization. In this report, we also compared sequencing techniques and a bioinformatic workflow on the data output when we assessed the IgH and Igκ variable gene usage. This included assessments of our bioinformatic workflow on Illumina HiSeq and MiSeq datasets and is specifically designed to reduce bias, capture the most information from Ig sequences, and produce a data set that provides other data mining options. We validated our workflow by comparing our normal mouse MiSeq data to existing murine antibody repertoire studies validating it for future antibody repertoire studies.
NASA Astrophysics Data System (ADS)
Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.
2003-09-01
The importance of small amounts of glass and paint evidence as a means to associate a crime event to a suspect or a suspect to another individual has been demonstrated in many cases. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. Previous work has demonstrated the utility of elemental analysis by solution ICP-MS of small amounts of glass for the comparison between a fragment found at a crime scene to a possible source of the glass. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The direct solid sample introduction technique of laser ablation (LA) is reported as an alternative to the solution method. Direct solid sampling provides several advantages over solution methods and shows great potential for a number of solid sample analyses in forensic science. The advantages of laser ablation include the simplification of sample preparation, thereby reducing the time and complexity of the analysis, the elimination of handling acid dissolution reagents such as HF and the reduction of sources of interferences in the ionization plasma. Direct sampling also provides for essentially "non-destructive" sampling due to the removal of very small amounts of sample needed for analysis. The discrimination potential of LA-ICP-MS is compared with previously reported solution ICP-MS methods using external calibration with internal standardization and a newly reported solution isotope dilution (ID) method. A total of ninety-one different glass samples were used for the comparison study using the techniques mentioned. One set consisted of forty-five headlamps taken from a variety of automobiles representing a range of twenty years of manufacturing dates. A second set consisted of forty-six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.
Tawasri, Patcharanee; Ampasavate, Chadarat; Tharatha, Somsak
2016-01-01
The objective of this randomized, open-label, single-dose, two-phase crossover study was to determine the effect of ascorbic acid on pharmacokinetics of ganoderic acid A, an important biologically active triterpenoid compound with anticancer activities, following oral administration of water extract of fruiting bodies of Ling Zhi in 12 healthy male subjects. Each subject was randomized to receive either one of the two regimens: (1) a single dose of 3,000 mg of the Ling Zhi preparation or (2) a single dose of 3,000 mg of the Ling Zhi preparation in combination with 2,500 mg of ascorbic acid. After a washout period of at least two weeks, subjects were switched to receive the alternate regimen. Blood samples were collected in each phase immediately before dosing and at specific time points for 8 hours after dosing. Plasma ganoderic acid A concentrations were quantified using liquid chromatography-mass spectrometry (LC-MS). The pharmacokinetic parameters analyzed were maximal plasma concentration (C max), time to reach peak concentration (T max), area under the plasma concentration-time curve (AUC), and half-life (t 1/2). An oral coadministration of ascorbic acid with Ling Zhi preparation did not significantly alter the pharmacokinetic parameters of ganoderic acid A in healthy male subjects. PMID:27747224
Microstructures and properties of rapidly solidified alloys
NASA Technical Reports Server (NTRS)
Shechtman, D.; Horowitz, E.
1984-01-01
The microstructure and properties of rapidly solidified aluminum alloys were researched. The effects of powder and flake chemistry and morphology and alternative consolidation processing parameters are being conducted. Samples of the powders being utilized were obtained for comprehensive metallurgical characterization. Seven aluminum alloys in the form of thin foils were studied by a variety of techniques including optical metallography, scanning electron microscope, and transmission electron microscope. Details of the microstructural characteristics are presented along with a discussion of the solidification process. A better understanding of the microstructure of the rapidly solidified aluminum alloys prepared by a variety of techniques such as roller quenching, the vacuum atomized procedure, ultrasonically atomized in inert atmospheres, and atomized in flue gas was provided.
Lack of latex allergen contamination of solutions withdrawn from vials with natural rubber stoppers.
Thomsen, D J; Burke, T G
2000-01-01
The effect on latex allergen contamination and microbial growth of a latex-allergy precaution technique for preparing injectable products was studied. The study consisted of three parts: (1) preparation of 20 samples from vials with latex-containing stoppers in accordance with conventional guidelines, (2) preparation of 20 samples in accordance with latex-allergy precaution guidelines, and (3) preparation of 5 latex-free samples and 1 latex-contaminated sample as negative and positive controls, respectively. The conventional method involved swabbing a vial top with an alcohol prep pad, puncturing the dry natural rubber stopper with an 18-gauge needle attached to a latex-free syringe, and withdrawing the contents of the vial into the syringe. The latex-allergy precaution preparation technique was similar, except that the stopper was removed before the vial contents were withdrawn. There was essentially no difference in latex allergen concentrations between the two drug preparation methods. None of the samples prepared with the standard method supported any microbial growth. One sample prepared with the latex-allergy precaution method grew bacteria. Removal of the dry rubber stopper from vials did not yield solutions with less latex allergen than solutions prepared according to conventional guidelines.
[Sample preparation and bioanalysis in mass spectrometry].
Bourgogne, Emmanuel; Wagner, Michel
2015-01-01
The quantitative analysis of compounds of clinical interest of low molecular weight (<1000 Da) in biological fluids is currently in most cases performed by liquid chromatography-mass spectrometry (LC-MS). Analysis of these compounds in biological fluids (plasma, urine, saliva, hair...) is a difficult task requiring a sample preparation. Sample preparation is a crucial part of chemical/biological analysis and in a sense is considered the bottleneck of the whole analytical process. The main objectives of sample preparation are the removal of potential interferences, analyte preconcentration, and converting (if needed) the analyte into a more suitable form for detection or separation. Without chromatographic separation, endogenous compounds, co-eluted products may affect a quantitative method in mass spectrometry performance. This work focuses on three distinct parts. First, quantitative bioanalysis will be defined, different matrices and sample preparation techniques currently used in bioanalysis by mass spectrometry of/for small molecules of clinical interest in biological fluids. In a second step the goals of sample preparation will be described. Finally, in a third step, sample preparation strategies will be made either directly ("dilute and shoot") or after precipitation.
Developing International Guidelines on Volcanic Hazard Assessments for Nuclear Facilities
NASA Astrophysics Data System (ADS)
Connor, Charles
2014-05-01
Worldwide, tremendous progress has been made in recent decades in forecasting volcanic events, such as episodes of volcanic unrest, eruptions, and the potential impacts of eruptions. Generally these forecasts are divided into two categories. Short-term forecasts are prepared in response to unrest at volcanoes, rely on geophysical monitoring and related observations, and have the goal of forecasting events on timescales of hours to weeks to provide time for evacuation of people, shutdown of facilities, and implementation of related safety measures. Long-term forecasts are prepared to better understand the potential impacts of volcanism in the future and to plan for potential volcanic activity. Long-term forecasts are particularly useful to better understand and communicate the potential consequences of volcanic events for populated areas around volcanoes and for siting critical infrastructure, such as nuclear facilities. Recent work by an international team, through the auspices of the International Atomic Energy Agency, has focused on developing guidelines for long-term volcanic hazard assessments. These guidelines have now been implemented for hazard assessment for nuclear facilities in nations including Indonesia, the Philippines, Armenia, Chile, and the United States. One any time scale, all volcanic hazard assessments rely on a geologically reasonable conceptual model of volcanism. Such conceptual models are usually built upon years or decades of geological studies of specific volcanic systems, analogous systems, and development of a process-level understanding of volcanic activity. Conceptual models are used to bound potential rates of volcanic activity, potential magnitudes of eruptions, and to understand temporal and spatial trends in volcanic activity. It is these conceptual models that provide essential justification for assumptions made in statistical model development and the application of numerical models to generate quantitative forecasts. It is a tremendous challenge in quantitative volcanic hazard assessments to encompass alternative conceptual models, and to create models that are robust to evolving understanding of specific volcanic systems by the scientific community. A central question in volcanic hazards forecasts is quantifying rates of volcanic activity. Especially for long-dormant volcanic systems, data from the geologic record may be sparse, individual events may be missing or unrecognized in the geologic record, patterns of activity may be episodic or otherwise nonstationary. This leads to uncertainty in forecasting long-term rates of activity. Hazard assessments strive to quantify such uncertainty, for example by comparing observed rates of activity with alternative parametric and nonparametric models. Numerical models are presented that characterize the spatial distribution of potential volcanic events. These spatial density models serve as the basis for application of numerical models of specific phenomena such as development of lava flow, tephra fallout, and a host of other volcanic phenomena. Monte Carlo techniques (random sampling, stratified sampling, importance sampling) are methods used to sample vent location and other key eruption parameters, such as eruption volume, magma rheology, and eruption column height for probabilistic models. The development of coupled scenarios (e.g., the probability of tephra accumulation on a slope resulting in subsequent debris flows) is also assessed through these methods, usually with the aid of event trees. The primary products of long-term forecasts are a statistical model of the conditional probability of the potential effects of volcanism, should an eruption occur, and the probability of such activity occurring. It is emphasized that hazard forecasting is an iterative process, and board consideration must be given to alternative conceptual models of volcanism, weighting of volcanological data in the analyses, and alternative statistical and numerical models. This structure is amenable to expert elicitation in order to weight alternative models and to explore alternative scenarios.
Shore, Sabrina; Henderson, Jordana M; Lebedev, Alexandre; Salcedo, Michelle P; Zon, Gerald; McCaffrey, Anton P; Paul, Natasha; Hogrefe, Richard I
2016-01-01
For most sample types, the automation of RNA and DNA sample preparation workflows enables high throughput next-generation sequencing (NGS) library preparation. Greater adoption of small RNA (sRNA) sequencing has been hindered by high sample input requirements and inherent ligation side products formed during library preparation. These side products, known as adapter dimer, are very similar in size to the tagged library. Most sRNA library preparation strategies thus employ a gel purification step to isolate tagged library from adapter dimer contaminants. At very low sample inputs, adapter dimer side products dominate the reaction and limit the sensitivity of this technique. Here we address the need for improved specificity of sRNA library preparation workflows with a novel library preparation approach that uses modified adapters to suppress adapter dimer formation. This workflow allows for lower sample inputs and elimination of the gel purification step, which in turn allows for an automatable sRNA library preparation protocol.
Dean, Wesley R; Sharkey, Joseph R; St John, Julie
2011-05-01
Accounts of the retail food environment have been limited by research that focused on supermarkets, grocery stores, and restaurants as the principal food sources for consumers. Little is known about alternative retail food sources, especially in rural and underserved areas such as the colonias along the South Texas border with Mexico. Many colonias are located near pulgas (flea markets). This is the first study to examine this alternative food source for colonia residents. This study's purpose is to provide preliminary data on food availability in this unstudied element of the retail food environment. Five pulgas were identified for study by local informants. Two separate teams of two promotores (indigenous community health workers) conducted observations, wrote field notes, and surveyed vendors in each pulga. Traditional foods, prepared foods, and fresh fruits and vegetables were available in the observed pulgas. Traditional foods included staples, meal items, and snacks and sweets. Prepared foods were available in small stands run by independent operators, and each pulga had permanent restaurants that served prepared foods. A large variety of fresh fruits and vegetables were also available. An emphasis on supermarkets and grocery stores will provide an incomplete account of the retail food environment. Further studies should attempt to provide a more complete account by identifying alternative retail sources used by local residents. One such alternative retail food source, the pulga, provides a range of traditional food stuffs, prepared food items, and fruits and vegetables that complement conventionally studied aspects of the retail food environment. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains the interim change notice for sample preparation methods. Covered are: acid digestion for metals analysis, fusion of Hanford tank waste solids, water leach of sludges/soils/other solids, extraction procedure toxicity (simulate leach in landfill), sample preparation for gamma spectroscopy, acid digestion for radiochemical analysis, leach preparation of solids for free cyanide analysis, aqueous leach of solids for anion analysis, microwave digestion of glasses and slurries for ICP/MS, toxicity characteristic leaching extraction for inorganics, leach/dissolution of activated metal for radiochemical analysis, extraction of single-shell tank (SST) samples for semi-VOC analysis, preparation and cleanup of hydrocarbon- containing samples for VOCmore » and semi-VOC analysis, receiving of waste tank samples in onsite transfer cask, receipt and inspection of SST samples, receipt and extrusion of core samples at 325A shielded facility, cleaning and shipping of waste tank samplers, homogenization of solutions/slurries/sludges, and test sample preparation for bioassay quality control program.« less
Effects of Sample Preparation on the Infrared Reflectance Spectra of Powders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brauer, Carolyn S.; Johnson, Timothy J.; Myers, Tanya L.
2015-05-22
While reflectance spectroscopy is a useful tool in identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-packedmore » as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.« less
Effects of sample preparation on the infrared reflectance spectra of powders
NASA Astrophysics Data System (ADS)
Brauer, Carolyn S.; Johnson, Timothy J.; Myers, Tanya L.; Su, Yin-Fong; Blake, Thomas A.; Forland, Brenda M.
2015-05-01
While reflectance spectroscopy is a useful tool for identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-loaded as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample can have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.
Alternatives for Saving and Viewing CAD Graphics for the Web.
ERIC Educational Resources Information Center
Harris, La Verne Abe; Sadowski, Mary A.
2001-01-01
Introduces some alternatives for preparing and viewing computer aided design (CAD) graphics for Internet output on a budget, without the fear of copyright infringement, and without having to go back to college to learn a complex graphic application. (Author/YDS)
Preparation of scanning tunneling microscopy tips using pulsed alternating current etching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan
An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE.more » The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)« less
Brorby, G P; Sheehan, P J; Berman, D W; Bogen, K T; Holm, S E
2011-05-01
Airborne samples collected in the 1970s for drywall workers using asbestos-containing joint compounds were likely prepared and analyzed according to National Institute of Occupational Safety and Health Method P&CAM 239, the historical precursor to current Method 7400. Experimentation with a re-created, chrysotile-containing, carbonate-based joint compound suggested that analysis following sample preparation by the historical vs. current method produces different fiber counts, likely because of an interaction between the different clearing and mounting chemicals used and the carbonate-based joint compound matrix. Differences were also observed during analysis using Method 7402, depending on whether acetic acid/dimethylformamide or acetone was used during preparation to collapse the filter. Specifically, air samples of sanded chrysotile-containing joint compound prepared by the historical method yielded fiber counts significantly greater (average of 1.7-fold, 95% confidence interval: 1.5- to 2.0-fold) than those obtained by the current method. In addition, air samples prepared by Method 7402 using acetic acid/dimethylformamide yielded fiber counts that were greater (2.8-fold, 95% confidence interval: 2.5- to 3.2-fold) than those prepared by this method using acetone. These results indicated (1) there is an interaction between Method P&CAM 239 preparation chemicals and the carbonate-based joint compound matrix that reveals fibers that were previously bound in the matrix, and (2) the same appeared to be true for Method 7402 preparation chemicals acetic acid/dimethylformamide. This difference in fiber counts is the opposite of what has been reported historically for samples of relatively pure chrysotile dusts prepared using the same chemicals. This preparation artifact should be considered when interpreting historical air samples for drywall workers prepared by Method P&CAM 239. Copyright © 2011 JOEH, LLC
Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging
NASA Astrophysics Data System (ADS)
Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee
2017-08-01
Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed.
MARS: bringing the automation of small-molecule bioanalytical sample preparations to a new frontier.
Li, Ming; Chou, Judy; Jing, Jing; Xu, Hui; Costa, Aldo; Caputo, Robin; Mikkilineni, Rajesh; Flannelly-King, Shane; Rohde, Ellen; Gan, Lawrence; Klunk, Lewis; Yang, Liyu
2012-06-01
In recent years, there has been a growing interest in automating small-molecule bioanalytical sample preparations specifically using the Hamilton MicroLab(®) STAR liquid-handling platform. In the most extensive work reported thus far, multiple small-molecule sample preparation assay types (protein precipitation extraction, SPE and liquid-liquid extraction) have been integrated into a suite that is composed of graphical user interfaces and Hamilton scripts. Using that suite, bioanalytical scientists have been able to automate various sample preparation methods to a great extent. However, there are still areas that could benefit from further automation, specifically, the full integration of analytical standard and QC sample preparation with study sample extraction in one continuous run, real-time 2D barcode scanning on the Hamilton deck and direct Laboratory Information Management System database connectivity. We developed a new small-molecule sample-preparation automation system that improves in all of the aforementioned areas. The improved system presented herein further streamlines the bioanalytical workflow, simplifies batch run design, reduces analyst intervention and eliminates sample-handling error.
Preparation of School District Budgets with Microcomputer Electronic Spreadsheets.
ERIC Educational Resources Information Center
Hinitz, Herman J.
1996-01-01
Preparing a microcomputer electronic spreadsheet containing all relevant school district budgetary information is possible with currently available hardware and software (such as Lotus 1-2-3), despite random-access-memory limitations. Spreadsheets can provide financial summaries, inventory-control listings, scheduling alternatives,…
Reflections on Educating Educational Administrators.
ERIC Educational Resources Information Center
Miklos, Erwin; Chapman, Donald
This paper presents a history of educational administration among Canada's provinces, discusses the status of university preparation programs, and explores theories of formalized and alternative approaches. Before the 1950's, little interest existed in administrators' formal preparation. Consolidation of schools led to graduate programs, but the…
EXPEDITIOUS SOLVENT-FREE PREPARATION OF IONIC LIQUIDS USING MICROWAVES
Ambient temperature ionic liquids comprising 1,3-dialkylimidazolium cations have shown great promise as alternative solvents in view of their negligible vapor pressure, ease of handling and potential for recycling. An efficient solventless protocol for the preparation of a wide v...
On the Job Education: An Alternative for Special Operations Forces Officers
2010-04-01
flexibility of the ACSC OLMP has great advantages to support the alternative education for SOF majors. The OLMP executes the entire curriculum every...AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY ON THE JOB EDUCATION : AN ALTERNATIVE FOR SPECIAL OPERATIONS FORCES OFFICERS by...relatively low compared to conventional officers. Conventional officers have educational institutions at the major level that prepare them to understand
Trace element contamination in feather and tissue samples from Anna’s hummingbirds
Mikoni, Nicole A.; Poppenga, Robert H.; Ackerman, Joshua T.; Foley, Janet E.; Hazlehurst, Jenny; Purdin, Güthrum; Aston, Linda; Hargrave, Sabine; Jelks, Karen; Tell, Lisa A.
2017-01-01
Trace element contamination (17 elements; Be, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Ba, Hg, Tl, and Pb) of live (feather samples only) and deceased (feather and tissue samples) Anna's hummingbirds (Calypte anna) was evaluated. Samples were analyzed using inductively coupled plasma-mass spectrometry (ICP-MS; 17 elements) and atomic absorption spectrophotometry (Hg only). Mean plus one standard deviation (SD) was considered the benchmark, and concentrations above the mean + 1 SD were considered elevated above normal. Contour feathers were sampled from live birds of varying age, sex, and California locations. In order to reduce thermal impacts, minimal feathers were taken from live birds, therefore a novel method was developed for preparation of low mass feather samples for ICP-MS analysis. The study found that the novel feather preparation method enabled small mass feather samples to be analyzed for trace elements using ICP-MS. For feather samples from live birds, all trace elements, with the exception of beryllium, had concentrations above the mean + 1 SD. Important risk factors for elevated trace element concentrations in feathers of live birds were age for iron, zinc, and arsenic, and location for iron, manganese, zinc, and selenium. For samples from deceased birds, ICP-MS results from body and tail feathers were correlated for Fe, Zn, and Pb, and feather concentrations were correlated with renal (Fe, Zn, Pb) or hepatic (Hg) tissue concentrations. Results for AA spectrophotometry analyzed samples from deceased birds further supported the ICP-MS findings where a strong correlation between mercury concentrations in feather and tissue (pectoral muscle) samples was found. These study results support that sampling feathers from live free-ranging hummingbirds might be a useful, non-lethal sampling method for evaluating trace element exposure and provides a sampling alternative since their small body size limits traditional sampling of blood and tissues. The results from this study provide a benchmark for the distribution of trace element concentrations in feather and tissue samples from hummingbirds and suggests a reference mark for exceeding normal. Lastly, pollinating avian species are minimally represented in the literature as bioindicators for environmental trace element contamination. Given that trace elements can move through food chains by a variety of routes, our study indicates that hummingbirds are possible bioindicators of environmental trace element contamination.
Cross-sectional TEM specimen preparation for W/B{sub 4}C multilayer sample using FIB
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mondal, Puspen, E-mail: puspen@rrcat.gov.in; Pradhan, P. C.; Tiwari, Pragya
2016-05-23
A recent emergence of a cross-beam scanning electron microscopy (SEM)/focused-ion-beam (FIB) system have given choice to fabricate cross-sectional transmission electron microscopy (TEM) specimen of thin film multilayer sample. A 300 layer pair thin film multilayer sample of W/B{sub 4}C was used to demonstrate the specimen lift-out technique in very short time as compared to conventional cross-sectional sample preparation technique. To get large area electron transparent sample, sample prepared by FIB is followed by Ar{sup +} ion polishing at 2 kV with grazing incident. The prepared cross-sectional sample was characterized by transmission electron microscope.
System for autonomous monitoring of bioagents
Langlois, Richard G.; Milanovich, Fred P.; Colston, Jr, Billy W.; Brown, Steve B.; Masquelier, Don A.; Mariella, Jr., Raymond P.; Venkateswaran, Kodomudi
2015-06-09
An autonomous monitoring system for monitoring for bioagents. A collector gathers the air, water, soil, or substance being monitored. A sample preparation means for preparing a sample is operatively connected to the collector. A detector for detecting the bioagents in the sample is operatively connected to the sample preparation means. One embodiment of the present invention includes confirmation means for confirming the bioagents in the sample.
NASA Astrophysics Data System (ADS)
Al-Harrasi, Ahmed; Rehman, Najeeb Ur; Mabood, Fazal; Albroumi, Muhammaed; Ali, Liaqat; Hussain, Javid; Hussain, Hidayat; Csuk, René; Khan, Abdul Latif; Alam, Tanveer; Alameri, Saif
2017-09-01
In the present study, for the first time, NIR spectroscopy coupled with PLS regression as a rapid and alternative method was developed to quantify the amount of Keto-β-Boswellic Acid (KBA) in different plant parts of Boswellia sacra and the resin exudates of the trunk. NIR spectroscopy was used for the measurement of KBA standards and B. sacra samples in absorption mode in the wavelength range from 700-2500 nm. PLS regression model was built from the obtained spectral data using 70% of KBA standards (training set) in the range from 0.1 ppm to 100 ppm. The PLS regression model obtained was having R-square value of 98% with 0.99 corelationship value and having good prediction with RMSEP value 3.2 and correlation of 0.99. It was then used to quantify the amount of KBA in the samples of B. sacra. The results indicated that the MeOH extract of resin has the highest concentration of KBA (0.6%) followed by essential oil (0.1%). However, no KBA was found in the aqueous extract. The MeOH extract of the resin was subjected to column chromatography to get various sub-fractions at different polarity of organic solvents. The sub-fraction at 4% MeOH/CHCl3 (4.1% of KBA) was found to contain the highest percentage of KBA followed by another sub-fraction at 2% MeOH/CHCl3 (2.2% of KBA). The present results also indicated that KBA is only present in the gum-resin of the trunk and not in all parts of the plant. These results were further confirmed through HPLC analysis and therefore it is concluded that NIRS coupled with PLS regression is a rapid and alternate method for quantification of KBA in Boswellia sacra. It is non-destructive, rapid, sensitive and uses simple methods of sample preparation.
32 CFR 651.45 - Steps in preparing and processing an EIS.
Code of Federal Regulations, 2010 CFR
2010-07-01
... technical analyses are balanced with environmental analysis, the agency preferred alternative will not...) ENVIRONMENTAL QUALITY ENVIRONMENTAL ANALYSIS OF ARMY ACTIONS (AR 200-2) Environmental Impact Statement § 651.45... alternatives based on relevant factors including environmental, economic, and technical considerations and...
The desirability and feasibility of alternative means of financing transportation in Virginia.
DOT National Transportation Integrated Search
1978-01-01
The report was prepared in response to a request by the Legislature of Virginia, through Senate Joint Resolution 76, that a study be conducted on the desirability and feasibility of using alternative methods of financing not presently available to su...
Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review
Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro
2016-01-01
Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites. PMID:26904042
NASA Astrophysics Data System (ADS)
Shaten, Richard Jay
1998-12-01
Petroleum provides 90% of transportation energy needs. Domestic production is decreasing and global demand is increasing. Risk of escalating prices and supply interruptions are compounded by environmental and military externalities and lost opportunities from the failure to develop alternative domestic resources. Within the context of "energy contingency planning" municipalities should evaluate crisis mitigation strategies. Supply augmentation using domestic renewable fuels is proposed to avert future financial liabilities. A method for calculating the economic value of this strategy is demonstrated. An objective function and associated constraints represent the cost of preparing for each of three possible scenarios: status quo, inflationary and crisis. Constraints ensure that municipal fuel needs are met. Environmental costs may be included. Optimal solutions determine the fuel supply mix for each scenario. A 3 x 3 matrix presents the range of actual costs resulting from preparing for each scenario and subsequent three possible outcomes. The distribution of probabilities of the outcomes is applied to the cost matrix and an "expected value" of preparing for each scenario is calculated. An unanticipated crisis outcome results in. The expected value of the cost of preparing for a crisis is cast as an insurance premium against potential economic liability. Policy makers accept the crisis preparation fuel mix if: (a) they agree with the calculated penalty cost, or (b) they accept the burden of the insurance premium. Green Bay Wisconsin was chosen as a sample municipality. Results show that a perceived 10% chance of crisis requires an annual tax of 4.00 per household to avert economic impacts of 50 million. At a perceived 50% chance of crisis preparing for the crisis would begin to save the municipality money.
Bowers, Robert M.; Clum, Alicia; Tice, Hope; ...
2015-10-24
Background: The rapid development of sequencing technologies has provided access to environments that were either once thought inhospitable to life altogether or that contain too few cells to be analyzed using genomics approaches. While 16S rRNA gene microbial community sequencing has revolutionized our understanding of community composi tion and diversity over time and space, it only provides a crude estimate of microbial functional and metabolic potential. Alternatively, shotgun metagenomics allows comprehensive sampling of all genetic material in an environment, without any underlying primer biases. Until recently, one of the major bottlenecks of shotgun metagenomics has been the requirement for largemore » initial DNA template quantities during library preparation. Results: Here, we investigate the effects of varying template concentrations across three low biomass library preparation protocols on their ability to accurately reconstruct a mock microbial community of known composition. We analyze the effects of input DNA quantity and library preparation method on library insert size, GC content, community composition, assembly quality and metagenomic binning. We found that library preparation method and the amount of starting material had significant impacts on the mock community metagenomes. In particular, GC content shifted towards more GC rich sequences at the lower input quantities regardless of library prep method, the number of low quality reads that could not be mapped to the reference genomes increased with decreasing input quantities, and the different library preparation methods had an impact on overall metagenomic community composition. Conclusions: This benchmark study provides recommendations for library creation of representative and minimally biased metagenome shotgun sequencing, enabling insights into functional attributes of low biomass ecosystem microbial communities.« less
Wadhwa, Meenu; Bird, Chris; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian; Thorpe, Robin
2015-01-01
We assessed the feasibility of developing a suitable international reference standard for determination of in vitro biological activity of human sequence recombinant PEG-G-CSF products with a 20 kD linear PEG linked to the N-terminal methionyl residue of G-CSF (INN Filgrastim), produced using a conjugation process and coupling chemistry similar to that employed for the lead PEGfilgrastim product. Based on initial data which showed that the current WHO 2nd international standard, IS for G-CSF (09/136) or alternatively, a PEG-G-CSF standard with a unitage traceable to the G-CSF IS may potentially serve as the IS for PEG-G-CSF products, two candidate preparations of PEG-G-CSF were formulated and lyophilized at NIBSC. These preparations were tested by 23 laboratories using in vitro bioassays in a multi-centre collaborative study. Results indicated that on the basis of parallelism, the current WHO 2nd IS for G-CSF or any of the PEG-G-CSF samples could be used as the international standard for PEG-G-CSF preparations. However, because of the variability in potency estimates seen when PEG-G-CSF preparations were compared with the current WHO 2nd IS for G-CSF, a candidate PEG-G-CSF was suitable as the WHO IS. The preparation 12/188 was judged suitable to serve as the WHO IS based on in vitro biological activity data. Therefore, the preparation coded 12/188 was established by the WHO Expert Committee on Biological Standardization (ECBS) in 2013 as the WHO 1st IS for human PEGylated G-CSF with an assigned in vitro bioactivity of 10,000 IU per ampoule. PMID:25450254
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowers, Robert M.; Clum, Alicia; Tice, Hope
Background: The rapid development of sequencing technologies has provided access to environments that were either once thought inhospitable to life altogether or that contain too few cells to be analyzed using genomics approaches. While 16S rRNA gene microbial community sequencing has revolutionized our understanding of community composi tion and diversity over time and space, it only provides a crude estimate of microbial functional and metabolic potential. Alternatively, shotgun metagenomics allows comprehensive sampling of all genetic material in an environment, without any underlying primer biases. Until recently, one of the major bottlenecks of shotgun metagenomics has been the requirement for largemore » initial DNA template quantities during library preparation. Results: Here, we investigate the effects of varying template concentrations across three low biomass library preparation protocols on their ability to accurately reconstruct a mock microbial community of known composition. We analyze the effects of input DNA quantity and library preparation method on library insert size, GC content, community composition, assembly quality and metagenomic binning. We found that library preparation method and the amount of starting material had significant impacts on the mock community metagenomes. In particular, GC content shifted towards more GC rich sequences at the lower input quantities regardless of library prep method, the number of low quality reads that could not be mapped to the reference genomes increased with decreasing input quantities, and the different library preparation methods had an impact on overall metagenomic community composition. Conclusions: This benchmark study provides recommendations for library creation of representative and minimally biased metagenome shotgun sequencing, enabling insights into functional attributes of low biomass ecosystem microbial communities.« less
Cryo-electron microscopy and cryo-electron tomography of nanoparticles.
Stewart, Phoebe L
2017-03-01
Cryo-transmission electron microscopy (cryo-TEM or cryo-EM) and cryo-electron tomography (cryo-ET) offer robust and powerful ways to visualize nanoparticles. These techniques involve imaging of the sample in a frozen-hydrated state, allowing visualization of nanoparticles essentially as they exist in solution. Cryo-TEM grid preparation can be performed with the sample in aqueous solvents or in various organic and ionic solvents. Two-dimensional (2D) cryo-TEM provides a direct way to visualize the polydispersity within a nanoparticle preparation. Fourier transforms of cryo-TEM images can confirm the structural periodicity within a sample. While measurement of specimen parameters can be performed with 2D TEM images, determination of a three-dimensional (3D) structure often facilitates more spatially accurate quantization. 3D structures can be determined in one of two ways. If the nanoparticle has a homogeneous structure, then 2D projection images of different particles can be averaged using a computational process referred to as single particle reconstruction. Alternatively, if the nanoparticle has a heterogeneous structure, then a structure can be generated by cryo-ET. This involves collecting a tilt-series of 2D projection images for a defined region of the grid, which can be used to generate a 3D tomogram. Occasionally it is advantageous to calculate both a single particle reconstruction, to reveal the regular portions of a nanoparticle structure, and a cryo-electron tomogram, to reveal the irregular features. A sampling of 2D cryo-TEM images and 3D structures are presented for protein based, DNA based, lipid based, and polymer based nanoparticles. WIREs Nanomed Nanobiotechnol 2017, 9:e1417. doi: 10.1002/wnan.1417 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.
Prophylactic and Treatment Drugs for Organophosphorus Poisoning
1991-01-01
our study, however, this procedure gave extremely low yields (9), so an alternate route to intermediate 2, was developed. The Grignard reagent , prepared...substituted methylphosphinates. The Grignard reagent , prepared from l-bromonaphthalene, was treated with N,N-diethyl-P-methylphosphonamidic, chloride and the...The Grignard reagent prepared from l-bromo-4-methyl- naphthalene was treated with N,N-diethyl-P-methylphosphonamidic chloride. The resulting amide was
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... Prepare a Draft Environmental Impact Statement for the Bogue Banks Coastal Storm Damage Reduction... alternatives to reduce coastal storm damages from beach erosion on Bogue Banks North Carolina. The Bogue Banks.... This area [[Page 17037
Can the Teaching Profession Be Trusted?
ERIC Educational Resources Information Center
Hitz, Randy
2008-01-01
Teacher preparation and licensing are constantly under attack from both national and state policy makers. The extraordinary reporting requirements imposed on university-based teacher preparation programs through Title II of the Higher Education Act and the promotion of "alternative routes" to teacher licensure by the federal government…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.
2007-12-01
The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includesmore » an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.« less
[Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].
Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo
2016-03-01
The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irving, J.S.
DOE prepared an environmental assessment (EA)for wildland fire management activities on the Idaho National Engineering and Environmental Laboratory (INEEL) (DOE/EA-1372). The EA was developed to evaluate wildland fire management options for pre-fire, fire suppression, and post fire activities. Those activities have an important role in minimizing the conversion of the native sagebrush steppe ecosystem found on the INEEL to non-native weeds. Four alternative management approaches were analyzed: Alternative 1 - maximum fire protection; Alternative 2 - balanced fire protection; Alternative 2 - balanced fire protection; Alternative 3 - protect infrastructure and personnel; and Alternative 4 - no action/traditional fire protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irving, John S
DOE prepared an environmental assessment (EA)for wildland fire management activities on the Idaho National Engineering and Environmental Laboratory (INEEL) (DOE/EA-1372). The EA was developed to evaluate wildland fire management options for pre-fire, fire suppression, and post fire activities. Those activities have an important role in minimizing the conversion of the native sagebrush steppe ecosystem found on the INEEL to non-native weeds. Four alternative management approaches were analyzed: Alternative 1 - maximum fire protection; Alternative 2 - balanced fire protection; Alternative 2 - balanced fire protection; Alternative 3 - protect infrastructure and personnel; and Alternative 4 - no action/traditional fire protection.
Yoshida, Yasuyuki; Takata, Kazuyuki; Takai, Hiroki; Kawahara, Keisuke; Kuzuya, Akinori; Ohya, Yuichi
2017-10-01
On clinical application of biodegradable injectable polymer (IP) systems, quick extemporaneous preparation of IP formulations and longer duration time gel state after injection into the body are the important targets to be developed. Previously, we had reported temperature-responsive covalent gelation systems via bio-orthogonal thiol-ene reaction by 'mixing strategy' of amphiphilic biodegradable tri-block copolymer (tri-PCG) attaching acryloyl groups on both termini (tri-PCG-Acryl) with reactive polythiol. In other previous works, we found 'freeze-dry with PEG/dispersion' method as quick extemporaneous preparation method of biodegradable IP formulations. In this study, we applied this quick preparative method to the temperature-triggered covalent gelation system. The instant formulation (D-sample) could be prepared by 'freeze-dry with PEG/dispersion' just mixing of tri-PCG-Acryl micelle dispersion and tri-PCG/DPMP micelle dispersion with PEG, that can be prepared in 30 s from the dried samples. The obtained D-sample showed irreversible gelation and long duration time of gel state, which was basically the same as the formulations prepared by the usual heating dissolution method (S-sample). Interestingly, the D-sample could maintain its sol state for a longer time (24 h) after preparing the formulation at r.t. compared with the S-sample, which became a gel in 3 h after preparing. The IP system showed good biocompatibility and long duration time of the gel state after subcutaneous implantation. These characteristics of D-samples, quick extemporaneous preparation and high stability in the sol state before injection, would be very convenient in a clinical setting.
Effect of Genetic Database Comprehensiveness on Fractional Proteomics of Escherichia coli O157:H7
2014-01-01
proteins would be observed in the extracellular fraction. 15. SUBJECT TERMS Escherichia coli O157:H7 Liquid chromatography Mass spectrometry...Preparation ...............1 2.2 Liquid Chromatography /Mass Spectrometry Sample Preparation ....................2 2.3 Liquid Chromatography /Mass... Chromatography /Mass Spectrometry Sample Preparation. Samples were prepared for liquid chromatography tandem mass spectrometry (LC-MS/MS) in a similar
Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda
2018-01-01
Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.
Beyer, Andreas; Grohganz, Holger; Löbmann, Korbinian; Rades, Thomas; Leopold, Claudia S
2017-06-30
Improvement of the physicochemical properties of amorphous active pharmaceutical ingredients (APIs) applying the concept of co-amorphisation is a promising alternative to the use of polymer glass solutions. In co-amorphous systems, the physical stability and the dissolution rate of the involved components may be improved in comparison to the respective single amorphous phases. However, for the co-amorphous naproxen-indomethacin model system it has been reported that recrystallization could not be prevented for more than 112days regardless of the applied preparation method and blend ratio In the present study, it was thus tested if the physicochemical properties of co-amorphous naproxen-indomethacin could be optimized by incorporation of the naproxen sodium into the system. Three different co-amorphous systems in nine different molar ratios were prepared by quench-cooling: naproxen-indomethacin (NI), naproxen-sodium-naproxen-indomethacin (NSNI) and naproxen-sodium-indomethacin (NSI). The samples were analyzed by XRPD, FTIR, DSC and by intrinsic dissolution experiments to investigate the influence of naproxen-sodium on the resulting physicochemical properties of the systems. With the three systems, fully amorphous samples with single glass transition temperatures could be prepared with naproxen molar fractions up to 0.7. The NSI and NSNI systems showed up to about 40°C higher Tgs than the NI system. Furthermore, no recrystallization occurred during 270d of storage with the NSI and NSNI samples that were initially amorphous. Moreover, with the NSI system, the intrinsic dissolution rate of naproxen and indomethacin was improved by a factor of 2 compared to the unmodified NI system. In conclusion, the physical stability as well as the dissolution rate was significantly improved if partial or full exchange of naproxen by its sodium salt was performed, which may present a general optimization method to improve co-amorphous systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Non-destructive NIR-FT-Raman spectroscopy of plant and animal tissues, of food and works of art.
Schrader, B; Schulz, H; Andreev, G N; Klump, H H; Sawatzki, J
2000-10-02
Just after the discovery of Raman spectroscopy in 1928, it became evident that fluorescence with a quantum yield of several orders of magnitude higher than that of the Raman effect was a great and apparently unbeatable competitor. Raman spectroscopy could therefore, in spite of many exciting advantages during the last 60 years, not be applied as an analytical routine method: for nearly every sample, fluorescing impurities had to be removed by distillation or crystallisation. Purification, however, is not possible for cells and tissues, since the removal of the fluorescing enzymes and coenzymes would destroy the cells. There is fortunately one alternative solution. When excited with the radiation of the Nd:YAG laser at 1064 nm Raman spectra are practically free of fluorescence. Raman spectra can now be recorded with minimal sample preparation. In order to facilitate non-destructive Raman spectroscopy of any sample, cells and tissues, food, textiles and works of art, a new entrance optics for Raman spectrometers is used. Typical results from several fields are demonstrated.
NASA Astrophysics Data System (ADS)
Masoumi, Masoud; Wang, Ya; Liu, Mingzhao; Tewolde, Mahder; Longtin, Jon
2015-04-01
In this work, nano-transducers with a superparamagnetic iron oxide (SPIO) core have been synthesized by preparation of precursor gold nanoseeds loaded on SPIO-embedded silica to form a gold nanoshell. The goal is for such nanotansducers to be used in theranostics to detect brain tumors by using MRI imaging and then assist in their treatment by using photothermal ablation. The iron oxide core provides for the use of a magnetic-field to guide the particles to the target (tumor) site. The gold nanoshell can be then readily heated using incident light and/or an alternating magneticfield. After synthesis of nano-transducer samples, Transmission Electron Microscopy was employed to analyze the formation of each layer. Then UV spectroscopy experiments were conducted to examine the light absorbance of the synthesized samples. The UV-visible absorption spectra shows a clear surface plasmon resonance (SPR) band around 530 nm, verifying the presence of gold coating nanoshells. Finally photothermal experiments using a high-power laser beam with a wavelength of 527 nm were performed to heat the samples. It was found that the temperature reaches 45° C in 12 minutes.
Pharmacokinetics Evaluation of Carbon Nanotubes Using FTIR Analysis and Histological Analysis.
Gherman, Claudia; Tudor, Matea Cristian; Constantin, Bele; Flaviu, Tabaran; Stefan, Razvan; Maria, Bindea; Chira, Sergiu; Braicu, Cornelia; Pop, Laura; Petric, Roxana Cojocneanu; Berindan-Neagoe, Ioana
2015-04-01
Carbon nanotubes (CNTs) are biologically non-toxic and long-circulating nanostructures that have special physical properties. This study was focused on developing alternative methods that track carbon nanotubes, like FR-IR to classical tissue histological procedure. FT-IR absorption spectra were used to confirm the carboxylation of carbon nanotubes and to evaluate the presence of carbon nanotubes from bulk spleen samples and histologically prepared samples (control spleen and spleen with SWCNT-COOH). FT-IR spectrum of spleen sample from animals injected with CNTs shows major spectral differences consisting in infrared bands located at ~1173 cm(-1), ~ 1410 cm(-1); ~1658 cm(-1), ~1737 cm(-1) and around 1720 cm(-1) respectively. In terms of localization of carbon nanotubes, selective accumulation of marginal zone macrophages and splenic red pulp is observed for all treated groups, indicating the presence of carbon nanotubes even at 3, 4 and 7 days after treatment. In summary, we believe that histological evaluation and FT-IR can provide more characteristic information about the pharmacokinetcis and the clearance of carbon nanotubes.
NASA Astrophysics Data System (ADS)
Kondo, T.; Mori, K.; Hachisu, M.; Yamazaki, T.; Okamoto, D.; Watanabe, M.; Gonda, K.; Tada, H.; Hamada, Y.; Takano, M.; Ohuchi, N.; Ichiyanagi, Y.
2015-05-01
Mn-Zn ferrite, Mn1-xZnxFe2O4 nanoparticles encapsulated in amorphous SiO2 were prepared using our original wet chemical method. X-ray diffraction patterns confirmed that the diameters of these particles were within 7-30 nm. Magnetization measurements for various sample compositions revealed that the saturation magnetization (Ms) of 7 nm particles was maximum for the x = 0.2 sample. AC magnetic susceptibility measurements were performed for Mn0.8Zn0.2Fe2O4 (x = 0.2) samples with 13-30 nm particles. The peak of the imaginary part of the magnetic susceptibility χ″ shifted to higher temperatures as the particle size increased. An AC field was found to cause the increase in temperature, with the 18 nm particles exhibiting the highest temperature increase, as expected. In addition, in vitro experiments were carried out to study the hyperthermia effects of Mn1-xZnxFe2O4 (x = 0.2, 18 nm) particles on human cancer cells.
Ong, Kheng Yong; Lim, Wei Ching; Ooi, Shing Ming; Loh, Zhi Hui; Kong, Ming Chai; Chan, Lai Wah; Heng, Paul Wan Sia
2017-05-01
There are no commercially available nasal irrigation solutions containing corticosteroids. Instead, such preparations are extemporaneously prepared by adding existing corticosteroid formulations to nasal irrigation solutions. The stability of the corticosteroid betamethasone 17-valerate (B17V), in nasal irrigation solutions of different compositions and pH and stored under different temperatures, was studied to determine the optimal choice of solution and storage conditions. Triplicate extemporaneous preparations made with B17V were prepared by adding a predetermined volume of B17V lotion to each nasal irrigation solution: normal saline (NS), sodium bicarbonate (NaHCO 3 ) powder dissolved in tap water, and a commercially available powder mixture (FLO Sinus Care Powder), dissolved in tap water or pre-boiled tap water. Preparations were stored at 30°C and 4°C. Sampling was carried out at 0, 1, 2, 6, and 24 hours. The concentrations of B17V and its degradation compound, betamethasone 21-valerate (B21V), were determined by high-performance liquid chromatography. Preparations stored at 30°C contained a lower amount of B17V and higher amount of B21V than those stored at 4°C. B17V stability in nasal irrigation solutions decreased in the following order: NS, FLO in fresh tap water, FLO in pre-boiled tap water, and NaHCO 3 . The degradation rate of B17V increased with higher storage temperature and higher pH. B17V is most stable when added to NS and least stable in NaHCO 3 solution. FLO solution prepared with either cooled boiled water or tap water is an alternative if administered immediately. Storage at 4°C can better preserve stability of B17V, over a period of 24 hours. © 2017 ARS-AAOA, LLC.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
... DEPARTMENT OF AGRICULTURE Natural Resources Conservation Service Non-Rock Alternatives to...: Natural Resources Conservation Service, Department of Agriculture. ACTION: Notice of Finding of No... of Agriculture, gives notice that an environmental impact statement is not being prepared for the Non...
A Best Practices Model for Preparation of Rural Special Education Teachers.
ERIC Educational Resources Information Center
Cegelka, Patricia A.; Alvarado, Jose Luis
2000-01-01
A district-university partnership program provides an alternative route to teacher certification for noncredentialed special education teachers working in a rural California desert region. The program features locally available courses, on-campus summer courses, an alternative internship credential, collaborative structure, a coach-of-coaches…
Comparison of University-Based Teacher Certification Programs and Alternative Certification Programs
ERIC Educational Resources Information Center
Roberts, Keonna
2016-01-01
The purpose of this qualitative study was to understand further similarities and differences between traditionally certified teachers and alternatively certified teachers specifically in the areas of teacher self-efficacy, classroom management, and teacher perceptions of their preparation program. The following research questions guided this…
Integrating Graduate Coursework to Prepare Alternatively Certified Teachers
ERIC Educational Resources Information Center
Heineke, Amy J.; Preach, Deborah
2013-01-01
In this article, we describe our innovative work as teacher educators to integrate coursework for alternatively certified teachers. Rather than maintain boundaries among individual courses for new elementary teachers, explicit connections support first-year teachers professional learning and aid in the immediate application to classroom practice.…
Extending the solvent-free MALDI sample preparation method.
Hanton, Scott D; Parees, David M
2005-01-01
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important technique to characterize many different materials, including synthetic polymers. MALDI mass spectral data can be used to determine the polymer average molecular weights, repeat units, and end groups. One of the key issues in traditional MALDI sample preparation is making good solutions of the analyte and the matrix. Solvent-free sample preparation methods have been developed to address these issues. Previous results of solvent-free or dry prepared samples show some advantages over traditional wet sample preparation methods. Although the results of the published solvent-free sample preparation methods produced excellent mass spectra, we found the method to be very time-consuming, with significant tool cleaning, which presents a significant possibility of cross contamination. To address these issues, we developed an extension of the solvent-free method that replaces the mortar and pestle grinding with ball milling the sample in a glass vial with two small steel balls. This new method generates mass spectra with equal quality of the previous methods, but has significant advantages in productivity, eliminates cross contamination, and is applicable to liquid and soft or waxy analytes.
Chandel, Siddhartha; Khan, Mohsin Ali; Singh, Nishi; Agrawal, Amiya; Khare, Vinita
2017-01-01
Present study is designed to explore the effect of sodium bicarbonate oral rinse on salivary pH and oral micro flora. Twenty five healthy subjects were recruited for the study in department of dentistry in Era Medical College. Subjects were abstained from tooth brushing overnight pre rinse (control) samples were collected after one hour of dinner and were asked to rinse with pre calibrated freshly prepared sodium bicarbonate solution. The salivary samples were then collected the following morning using sterile gauze in marked bottles. Aerobic bacterial culture was done by plating the sample directly from the swab on the surface of Blood agar and Mac Conkeys media respectively. The colony forming units and ph were calculated for the pre rinse and post rinse saliva sample. Results shows that salivary pH increased significantly after sodium Bicarbonate oral rinse. There was a marginal decrease in number of CFU/ml for bacteria especially Viridans Streptococci, Moraxella species. Sodium Bicarbonate oral rinse may be considered as a cheap and effective alternative for chlorhexidine and alcohol based mouth wash, especially where long duration usage is required.
Kurniawan, Koo Hendrik; Pardede, Marincan; Hedwig, Rinda; Abdulmadjid, Syahrun Nur; Lahna, Kurnia; Idris, Nasrullah; Jobiliong, Eric; Suyanto, Hery; Suliyanti, Maria Margaretha; Tjia, May On; Lie, Tjung Jie; Lie, Zener Sukra; Kurniawan, Davy Putra; Kagawa, Kiichiro
2015-09-01
We have conducted an experimental study exploring the possible application of laser-induced breakdown spectroscopy (LIBS) for practical and highly sensitive detection of metal impurities in water. The spectrochemical measurements were carried out by means of a 355 nm Nd-YAG laser within N2 and He gas at atmospheric pressures as high as 2 kPa. The aqueous samples were prepared as thin films deposited on indium-tin oxide (ITO) glass by an electrolysis process. The resulting emission spectra suggest that concentrations at parts per billion levels may be achieved for a variety of metal impurities, and it is hence potentially feasible for rapid inspection of water quality in the semiconductor and pharmaceutical industries, as well as for cooling water inspection for possible leakage of radioactivity in nuclear power plants. In view of its relative simplicity, this LIBS equipment offers a practical and less costly alternative to the standard use of inductively coupled plasma-mass spectrometry (ICP-MS) for water samples, and its further potential for in situ and mobile applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tumey, S J; Brown, T A; Hamilton, T F
2008-03-03
Strontium-90 is one of the most hazardous materials managed by agencies charged with protecting the public from radiation. Traditional radiometric methods have been limited by low sample throughput and slow turnaround times. Mass spectrometry offers the advantage of shorter analysis times and the ability to measure samples immediately after processing, however conventional mass spectrometric techniques are susceptible to molecular isobaric interferences that limit their overall sensitivity. In contrast, accelerator mass spectrometry is insensitive to molecular interferences and we have therefore begun developing a method for determination of {sup 90}Sr by accelerator mass spectrometry. Despite a pervasive interference from {sup 90}Zr,more » our initial development has yielded an instrumental background of {approx} 10{sup 8} atoms (75 mBq) per sample. Further refinement of our system (e.g., redesign of our detector, use of alternative target materials) is expected to push the background below 10{sup 6} atoms, close to the theoretical limit for AMS. Once we have refined our system and developed suitable sample preparation protocols, we will utilize our capability in applications to homeland security, environmental monitoring, and human health.« less
Producing liquid fuels from biomass
NASA Astrophysics Data System (ADS)
Solantausta, Yrjo; Gust, Steven
The aim of this survey was to compare, on techno-economic criteria, alternatives of producing liquid fuels from indigenous raw materials in Finland. Another aim was to compare methods under development and prepare a proposal for steering research related to this field. Process concepts were prepared for a number of alternatives, as well as analogous balances and production and investment cost assessments for these balances. Carbon dioxide emissions of the alternatives and the price of CO2 reduction were also studied. All the alternatives for producing liquid fuels from indigenous raw materials are utmost unprofitable. There are great differences between the alternatives. While the production cost of ethanol is 6 to 9 times higher than the market value of the product, the equivalent ratio for substitute fuel oil produced from peat by pyrolysis is 3 to 4. However, it should be borne in mind that the technical uncertainties related to the alternatives are of different magnitude. Production of ethanol from barley is of commercial technology, while biomass pyrolysis is still under development. If the aim is to reach smaller carbon dioxide emissions by using liquid biofuels, the most favorable alternative is pyrolysis oil produced from wood. Fuels produced from cultivated biomass are more expensive ways of reducing CO2 emissions. Their potential of reducing CO2 emissions in Finland is insignificant. Integration of liquid fuel production to some other production line is more profitable.
Sample Preparation for Electron Probe Microanalysis—Pushing the Limits
Geller, Joseph D.; Engle, Paul D.
2002-01-01
There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the “k-ratios,” to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very important, and, under certain conditions, may even be the limiting factor in the analytical uncertainty budget. This paper considers preparing samples to get known geometries. It will not address the analysis of samples with irregular, unprepared surfaces or unknown geometries. PMID:27446757
Practicing Collaboration in Teacher Preparation: Effects of Learning by Doing Together
ERIC Educational Resources Information Center
Weiss, Margaret P.; Pellegrino, Anthony; Brigham, Frederick J.
2017-01-01
Collaboration among professionals is a vital component for successful inclusion of students with disabilities. In many cases, teacher preparation programs assume that teacher candidates know how to collaborate without explicit instruction or authentic practice and, therefore, omit coursework on collaboration. Alternatively, some programs may…
Formulation, Preparation, and Characterization of Polyurethane Foams
ERIC Educational Resources Information Center
Pinto, Moises L.
2010-01-01
Preparation of laboratory-scale polyurethane foams is described with formulations that are easy to implement in experiments for undergraduate students. Particular attention is given to formulation aspects that are based on the main chemical reactions occurring in polyurethane production. This allows students to develop alternative formulations to…
A Randomized Controlled Comparison of Esophageal Clearance Times of Oral Budesonide Preparations.
Hefner, Jody N; Howard, Robin S; Massey, Robert; Valencia, Miland; Stocker, Derek J; Philla, Katherine Q; Goldman, Matthew D; Nylund, Cade M; Min, Steve B
2016-06-01
Topical steroids prepared as oral viscous slurries have become common in the treatment of eosinophilic esophagitis. Esophageal mucosal contact time correlates with clinical and histologic improvement. To compare the mucosal contact time of alternative oral viscous budesonide (OVB) slurries with the conventional sucralose OVB. A blinded randomized crossover trial investigating esophageal clearance of three OVB slurry preparations was done on healthy adults. Honey and xanthan gum OVB slurries were compared with standard sucralose OVB in 24 randomly assigned subjects. Each subject ingested the sucralose OVB and either the honey or xanthan gum OVB slurries. The esophageal clearance of each slurry was evaluated as an area under the curve (AUC) using 1 millicurie of technetium-99m-sulfur colloid (Tc99) co-administered in each OVB preparation using nuclear scintigraphy. A standardized taste survey was also administered. Xanthan gum had greater mucosal contact time compared to sucralose as measured by a higher AUC at 3 min (P = 0.002), while honey showed no significant difference in esophageal clearance relative to sucralose. Taste scores were significantly higher in the honey group, while scores for xanthan gum were no different from standard sucralose. OVB slurries utilizing xanthan gum may be a superior alternative to a sucralose-based slurry due to its increased mucosal contact time and similar taste tolerance. Honey may be a suitable alternative as well, due to its similar contact time and favorable taste.
Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation
NASA Technical Reports Server (NTRS)
Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.
2004-01-01
Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.
Gelatin prepared from tuna skin: a risk factor for fish allergy or sensitization?
André, Françoise; Cavagna, Sylvie; André, Claude
2003-01-01
Although fish gelatin may represent a useful alternative to bovine or porcine gelatin, the clearly recognized high prevalence of fish allergy could increase the risk of anaphylaxis to gelatin. The rationale for investigating tuna gelatin rather than gelatin from more allergenic fishes is the availability of an industrial gelatin under development. The infrequent occurrence of tuna allergy should influence the safety of a derived product. The present study investigated IgE antibodies to tuna-skin-derived gelatin in adults and children with documented fish allergy or sensitization. Serum samples were taken from 100 consecutive patients with fish allergy or sensitization and tested for IgE antibodies against hydrolyzed or nonhydrolyzed gelatin extracted from tuna skin as compared to extracts from tuna flesh, tuna skin as well as bovine or porcine gelatin. Patients with tuna allergies or sensitization were sensitive to the same tuna species (yellowfin) as that from which the gelatin was obtained. IgE antibodies to these various extracts were analyzed using SDS-PAGE and immunoblotting. Only 3 of the 100 serum samples tested gave evidence of reactivity to gelatin extracted from tuna skin. Cross-reactivity between bovine/porcine and fish gelatin was not observed. The risk of adverse reactions to tuna skin gelatin seems to be significantly lower than the risk of fish allergy. Fish gelatin may represent a valuable alternative to bovine or porcine gelatin. Copyright 2003 S. Karger AG, Basel
Kwak, Ho-Seok; Chung, Hee-Jung; Choi, Young Sik; Min, Won-Ki; Jung, So Young
2015-07-01
Fetal lung maturity is estimated using the lecithin/sphingomyelin ratio (L/S ratio) in amniotic fluid and it is commonly measured with thin-layer chromatography (TLC). The TLC method is time consuming and technically difficult; however, it is widely used because there is no alternative. We evaluated a novel method for measuring the L/S ratio, which involves a tip-column with a cation-exchange resin and mass spectrometry. Phospholipids in the amniotic fluid were extracted using methanol and chloroform. Choline-containing phospholipids such as lecithin and sphingomyelin were purified by passing them through the tip-column. LC-MS/MS and MALDI-TOF were used to directly analyze the purified samples. The L/S ratio by mass spectrometry was calculated from the sum peak intensity of the six lecithin, and that of sphingomyelin 34:1. In 20 samples, the L/S ratio determined with TLC was significantly correlated with that obtained by LC-MS/MS and MALDI-TOF. There was a 100% concordance between the L/S ratio by TLC and that by LC-MS/MS (kappa value=1.0). The concordance between the L/S ratio by TLC and that by MALDI-TOF was also 100% (kappa value=1.0). Our method provides a faster, simpler, and more reliable assessment of fetal lung maturity. The L/S ratio measured by LC-MS/MS and MALDI-TOF offers a compelling alternative method to traditional TLC. Copyright © 2015 Elsevier B.V. All rights reserved.
Gerhardt, Natalie; Birkenmeier, Markus; Schwolow, Sebastian; Rohn, Sascha; Weller, Philipp
2018-02-06
This work describes a simple approach for the untargeted profiling of volatile compounds for the authentication of the botanical origins of honey based on resolution-optimized HS-GC-IMS combined with optimized chemometric techniques, namely PCA, LDA, and kNN. A direct comparison of the PCA-LDA models between the HS-GC-IMS and 1 H NMR data demonstrated that HS-GC-IMS profiling could be used as a complementary tool to NMR-based profiling of honey samples. Whereas NMR profiling still requires comparatively precise sample preparation, pH adjustment in particular, HS-GC-IMS fingerprinting may be considered an alternative approach for a truly fully automatable, cost-efficient, and in particular highly sensitive method. It was demonstrated that all tested honey samples could be distinguished on the basis of their botanical origins. Loading plots revealed the volatile compounds responsible for the differences among the monofloral honeys. The HS-GC-IMS-based PCA-LDA model was composed of two linear functions of discrimination and 10 selected PCs that discriminated canola, acacia, and honeydew honeys with a predictive accuracy of 98.6%. Application of the LDA model to an external test set of 10 authentic honeys clearly proved the high predictive ability of the model by correctly classifying them into three variety groups with 100% correct classifications. The constructed model presents a simple and efficient method of analysis and may serve as a basis for the authentication of other food types.
Coetzer, Andre; Sabeta, Claude T.; Markotter, Wanda; Rupprecht, Charles E.; Nel, Louis H.
2014-01-01
The major etiological agent of rabies, rabies virus (RABV), accounts for tens of thousands of human deaths per annum. The majority of these deaths are associated with rabies cycles in dogs in resource-limited countries of Africa and Asia. Although routine rabies diagnosis plays an integral role in disease surveillance and management, the application of the currently recommended direct fluorescent antibody (DFA) test in countries on the African and Asian continents remains quite limited. A novel diagnostic assay, the direct rapid immunohistochemical test (dRIT), has been reported to have a diagnostic sensitivity and specificity equal to that of the DFA test while offering advantages in cost, time and interpretation. Prior studies used the dRIT utilized monoclonal antibody (MAb) cocktails. The objective of this study was to test the hypothesis that a biotinylated polyclonal antibody (PAb) preparation, applied in the dRIT protocol, would yield equal or improved results compared to the use of dRIT with MAbs. We also wanted to compare the PAb dRIT with the DFA test, utilizing the same PAb preparation with a fluorescent label. The PAb dRIT had a diagnostic sensitivity and specificity of 100%, which was shown to be marginally higher than the diagnostic efficacy observed for the PAb DFA test. The classical dRIT, relying on two-biotinylated MAbs, was applied to the same panel of samples and a reduced diagnostic sensitivity (83.50% and 90.78% respectively) was observed. Antigenic typing of the false negative samples indicated all of these to be mongoose RABV variants. Our results provided evidence that a dRIT with alternative antibody preparations, conjugated to a biotin moiety, has a diagnostic efficacy equal to that of a DFA relying on the same antibody and that the antibody preparation should be optimized for virus variants specific to the geographical area of focus. PMID:25254652
Coetzer, Andre; Sabeta, Claude T; Markotter, Wanda; Rupprecht, Charles E; Nel, Louis H
2014-09-01
The major etiological agent of rabies, rabies virus (RABV), accounts for tens of thousands of human deaths per annum. The majority of these deaths are associated with rabies cycles in dogs in resource-limited countries of Africa and Asia. Although routine rabies diagnosis plays an integral role in disease surveillance and management, the application of the currently recommended direct fluorescent antibody (DFA) test in countries on the African and Asian continents remains quite limited. A novel diagnostic assay, the direct rapid immunohistochemical test (dRIT), has been reported to have a diagnostic sensitivity and specificity equal to that of the DFA test while offering advantages in cost, time and interpretation. Prior studies used the dRIT utilized monoclonal antibody (MAb) cocktails. The objective of this study was to test the hypothesis that a biotinylated polyclonal antibody (PAb) preparation, applied in the dRIT protocol, would yield equal or improved results compared to the use of dRIT with MAbs. We also wanted to compare the PAb dRIT with the DFA test, utilizing the same PAb preparation with a fluorescent label. The PAb dRIT had a diagnostic sensitivity and specificity of 100%, which was shown to be marginally higher than the diagnostic efficacy observed for the PAb DFA test. The classical dRIT, relying on two-biotinylated MAbs, was applied to the same panel of samples and a reduced diagnostic sensitivity (83.50% and 90.78% respectively) was observed. Antigenic typing of the false negative samples indicated all of these to be mongoose RABV variants. Our results provided evidence that a dRIT with alternative antibody preparations, conjugated to a biotin moiety, has a diagnostic efficacy equal to that of a DFA relying on the same antibody and that the antibody preparation should be optimized for virus variants specific to the geographical area of focus.
Ozay, Guner; Seyhan, Ferda; Yilmaz, Aysun; Whitaker, Thomas B; Slate, Andrew B; Giesbrecht, Francis
2006-01-01
The variability associated with the aflatoxin test procedure used to estimate aflatoxin levels in bulk shipments of hazelnuts was investigated. Sixteen 10 kg samples of shelled hazelnuts were taken from each of 20 lots that were suspected of aflatoxin contamination. The total variance associated with testing shelled hazelnuts was estimated and partitioned into sampling, sample preparation, and analytical variance components. Each variance component increased as aflatoxin concentration (either B1 or total) increased. With the use of regression analysis, mathematical expressions were developed to model the relationship between aflatoxin concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific aflatoxin concentration. The sampling, sample preparation, and analytical variances associated with estimating aflatoxin in a hazelnut lot at a total aflatoxin level of 10 ng/g and using a 10 kg sample, a 50 g subsample, dry comminution with a Robot Coupe mill, and a high-performance liquid chromatographic analytical method are 174.40, 0.74, and 0.27, respectively. The sampling, sample preparation, and analytical steps of the aflatoxin test procedure accounted for 99.4, 0.4, and 0.2% of the total variability, respectively.
7 CFR 61.34 - Drawing and preparation of sample.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Drawing and preparation of sample. 61.34 Section 61.34 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Cottonseed Samplers § 61.34 Drawing and preparation of sample. Each licensed cottonseed sampler shall draw...
The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...
Erlandsen, S L; Sherlock, L A; Bemrick, W J
1990-04-01
The effects of freezing and thawing on the detection of selected Giardia spp. cysts were investigated using immunofluorescence, bright field microscopy, and low voltage scanning electron microscopy (SEM). Giardia muris cysts were obtained from either animal carcasses, fecal pellets, or isolated cyst preparations, whereas Giardia lamblia cysts were isolated from fecal samples. These samples were stained using an immunofluorescence technique after 1-3 freezing (-16 C) and thawing (20 C) cycles. Cysts were detected successfully by immunofluorescence in all samples. However, in those samples subjected to freeze-thawing, the cyst walls often became distorted and then were not detectable by bright field microscopy. Low voltage SEM demonstrated that the filaments in the distorted cyst wall underwent rearrangements of interfilament spacing. Quantitation of cyst recovery after freezing and thawing demonstrated that a substantial loss occurred after 1 cycle of alternating temperature when low concentrations of cysts were used, but not with high concentrations of cysts. Cyst recovery, after 3 freezing and thawing cycles, was dramatically lowered irrespective of the initial cyst concentration. These results demonstrated that immunofluorescence was an effective technique for the detection of Giardia spp. cysts in frozen samples and would suggest that freezing and thawing of fecal samples could prevent the detection of cysts when only bright field microscopy was employed.
Students Teach Students: Alternative Teaching in Greek Secondary Education
ERIC Educational Resources Information Center
Theodoropoulos, Anastasios; Antoniou, Angeliki; Lepouras, George
2016-01-01
The students of a Greek junior high school collaborated to prepare the teaching material of a theoretical Computer Science (CS) course and then shared their understanding with other students. This study investigates two alternative teaching methods (collaborative learning and peer tutoring) and compares the learning results to the traditional…
ERIC Educational Resources Information Center
Greenberg, Julie; Walsh, Kate; McKee, Arthur
2014-01-01
The "NCTQ Teacher Prep Review" evaluates the quality of programs that provide preservice preparation of public school teachers. As part of the "Review," this appendix reports on a pilot study of new standards for assessing the quality of alternative certification programs. Background and methodology for alternative…
Using Taylor Expansions to Prepare Students for Calculus
ERIC Educational Resources Information Center
Lutzer, Carl V.
2011-01-01
We propose an alternative to the standard introduction to the derivative. Instead of using limits of difference quotients, students develop Taylor expansions of polynomials. This alternative allows students to develop many of the central ideas about the derivative at an intuitive level, using only skills and concepts from precalculus, and…
ALT-114 and ALT-118 Alternative Approaches to NIST-Traceable Reference Gases
In 2016, US EPA approved two separate alternatives (ALT 114 and ALT 118) for the preparation and certification of Hydrogen Chloride (HCl) and Mercury (Hg) cylinder reference gas standards that can serve as EPA Protocol gases where EPA Protocol are required, but unavailable. The a...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... experience for the visitors to this symbolic and historic cultural landscape. During the preparation of the... landscape reports and inventories. No-Action Alternative Under the No-Action Alternative, current management... landscape, with the large amount of deferred maintenance and aging infrastructure, pedestrian and bicycle...
Alternative Pathways into University: Are Tertiary Preparation Programs a Viable Option?
ERIC Educational Resources Information Center
Chesters, Jenny; Rutter, Kerry; Nelson, Karen; Watson, Louis
2018-01-01
During the past three decades, the student populations of Australian universities have become more heterogeneous as the higher education sector expanded and new alternative entry pathways were established. Broadening access to university study and, therefore, to professional and semi-professional occupations, provides avenues for social mobility.…
This investigation was conducted to assess the applicability of currently available (ca. 1992) alternative materials for use as daily cover at landfills. Information on characteristics, material and equipment requirements, methods of preparation and application, climatic and ope...
Alternative Routes for Teacher Certification.
ERIC Educational Resources Information Center
Education Commission of the States, Denver, CO.
This publication presents a series of charts, designed for quick reference, which describe the status of alternative teacher certification routes in each of the 50 states. The charts were prepared in response to an increasing number of inquiries from educators, policy makers, and the public. Information was gathered by telephone surveys of state…
ERIC Educational Resources Information Center
Strycker, Jesse D.
2011-01-01
Though an educational technology experience is required as part of a traditional teacher education program student's educational preparation, research has been limited into the experiences had by alternative teacher education program students. Similarly, little research has been done comparing technology experiences between both types of teacher…
An Analysis of Teacher Sorting in Secondary Special Education and Alternative Schools
ERIC Educational Resources Information Center
Mason-Williams, Loretta; Gagnon, Joseph Calvin
2017-01-01
This study provides nationally representative information about the qualifications and preparation of secondary content and special education teachers in special education and alternative school settings, as compared with teachers in regular schools. Findings demonstrate that a statistically significant relationship did not exist between school…
ERIC Educational Resources Information Center
Schuetze, Hans G., Ed.; Sweet, Robert, Ed.
This volume discusses "alternation," various combinations of classroom (organized, theoretical) knowledge and workplace (practical) learning in Canada intended to adequately prepare secondary and postsecondary graduates for work in the new economy. Following an introduction, "Integrating School and Workplace Learning in Canada: An…
ERIC Educational Resources Information Center
Ring, Candi Lynn
2016-01-01
Within the scientific literature there has been no examination of teacher preparation regarding classroom and behavior management skills comparing educators who obtained traditional teacher certification through a university-based education program and those who obtained alternative certification. Consequently, the goal of this study was to assess…
Method and apparatus for detecting cyber attacks on an alternating current power grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
McEachern, Alexander; Hofmann, Ronald
A method and apparatus for detecting cyber attacks on remotely-operable elements of an alternating current distribution grid. Two state estimates of the distribution grid are prepared, one of which uses micro-synchrophasors. A difference between the two state estimates indicates a possible cyber attack.
Sustainable Agriculture in Print: Current Books. Special Reference Briefs: SRB 95-02.
ERIC Educational Resources Information Center
National Agricultural Library, Beltsville, MD.
Prepared by the Alternative Farming Systems Information Center (AFSIC) staff and volunteers, this annotated bibliography provides a list of 85 recently published books pertaining to sustainable agriculture. AFSIC focuses on alternative farming systems (e.g., sustainable, low-input, regenerative, biodynamic, and organic) that maintain agricultural…
Entrapment of Bacteriocin 105B onto Fabric with Titania
2017-02-09
to fabricate a multifunctional textile exhibiting an alternative range of antimicrobial activity from that of nisin, by titania encapsulation of...105b onto fabric. The results of these initial studies suggest that both pure preparations and semi-pure preparations of 105b are active when...encapsulated in titania in solution. However, when the pure preparation of 105b is titania encapsulated on fabric, antimicrobial activity is not observed
Laser cleaning of steel for paint removal
NASA Astrophysics Data System (ADS)
Chen, G. X.; Kwee, T. J.; Tan, K. P.; Choo, Y. S.; Hong, M. H.
2010-11-01
Paint removal is an important part of steel processing for marine and offshore engineering. For centuries, a blasting techniques have been widely used for this surface preparation purpose. But conventional blasting always has intrinsic problems, such as noise, explosion risk, contaminant particles, vibration, and dust. In addition, processing wastes often cause environmental problems. In recent years, laser cleaning has attracted much research effort for its significant advantages, such as precise treatment, and high selectivity and flexibility in comparison with conventional cleaning techniques. In the present study, we use this environmentally friendly technique to overcome the problems of conventional blasting. Processed samples are examined with optical microscopes and other surface characterization tools. Experimental results show that laser cleaning can be a good alternative candidate to conventional blasting.
Determination of the viscosity number of thermoplastics in dilute solution; polyamides (PA)
NASA Technical Reports Server (NTRS)
1985-01-01
This West German Standard presents a test used to determine the viscosity number of polyamides and copolyamides which are easily diluted in sulfuric acid, and for other polyamides which are less easily diluted in sulfuric acid, and which are diluted in m-cresol. As formic acid is often used in industry instead of sulfuric acid, this solvent is also presented as an alternative, however, sulfuric acid is preferred because of the thermodynamic solubility characteristics of the polyamides and the handling safety. In addition, it is shown which solvent should be used for each polyamide. Finally, determinations concerning the preparation of the samples are presented. Using the viscosity number, a determination of the molar mass of the polyamides is possible.
Synthesis and characterization of polycrystalline brownmillerite cobalt doped Ca2Fe2O5
NASA Astrophysics Data System (ADS)
Dhankhar, Suchita; Bhalerao, Gopal; Baskar, K.; Singh, Shubra
2016-05-01
Brownmillerite compounds with general formula A2BB'O5 (BB' = Mn, Al, Fe, Co) have attracted attention in wide range of applications such as in solid oxide fuel cell, oxygen separation membrane and photocatalysis. Brownmillerite compounds have unique structure with alternate layers of BO6 octahedral layers and BO4 tetrahedral layers. Presence of dopants like Co in place of Fe increases oxygen vacancies. In the present work we have synthesized polycrystalline Ca2Fe2O5 and Ca2Fe1-xCoxO5 (x = 0.01, 0.03) by citrate combustion route. The as prepared samples were characterized by XRD using PANalytical X'Pert System, DRS (Diffuse reflectance spectroscopy) and SEM (Scanning electron microscopy).
Advances in bioanalytical techniques to measure steroid hormones in serum.
French, Deborah
2016-06-01
Steroid hormones are measured clinically to determine if a patient has a pathological process occurring in the adrenal gland, or other hormone responsive organs. They are very similar in structure making them analytically challenging to measure. Additionally, these hormones have vast concentration differences in human serum adding to the measurement complexity. GC-MS was the gold standard methodology used to measure steroid hormones clinically, followed by radioimmunoassay, but that was replaced by immunoassay due to ease of use. LC-MS/MS has now become a popular alternative owing to simplified sample preparation than for GC-MS and increased specificity and sensitivity over immunoassay. This review will discuss these methodologies and some new developments that could simplify and improve steroid hormone analysis in serum.
Kalinke, Cristiane; Oliveira, Paulo Roberto; Oliveira, Geovane Arruda; Mangrich, Antonio Sálvio; Marcolino-Junior, Luiz H; Bergamini, Márcio F
2017-08-29
This work reports for the first time the use of chemically activated biochar as electrode modifier for nickel determination. The biochar activation was performed by refluxing with HNO 3 , which promoted a higher nickel preconcentration compared to unmodified and modified biochar precursor electrodes. Morphological and structural characterization revealed the increase of surface acid groups, surface area and porosity of biochar after activation. Nickel determination was investigated adopting an alternative voltammetric methodology based on monitoring the Ni(II)/Ni(III) redox couple. In the proposed method, it was not necessary to use a complexing agent and the biochar itself was responsible for the analyte preconcentration. A linear response for Ni(II) concentration range from 1.0 to 30 μmol L -1 and a limit of detection of 0.25 μmol L -1 were obtained. The method was successfully applied for Ni(II) determination in spiked samples of bioethanol fuel and discharge water, with recoveries values between 103 and 109%. Copyright © 2017 Elsevier B.V. All rights reserved.
Searight, H. Russell; Robertson, Kayla; Smith, Todd; Perkins, Scott; Searight, Barbara K.
2012-01-01
Attention deficit hyperactivity disorder (AD/HD), characterized by impulsivity, distractibility, and inattention, has an estimated pediatric population prevalence of 6–8%. Family physicians and pediatricians evaluate and treat the majority of children with this condition. The evidence-based treatment of choice for ADHD, stimulant medication, continues to be a source of public controversy. Surveys suggest that among parents of children with ADHD, there is considerable interest in complementary and alternative medicine (CAM). These therapies include herbal preparations, mineral supplements, sugar restriction, and polyunsaturated fatty acids. Other AD/HD therapies include neuro-feedback, cognitive training, mindfulness meditation, and exposure to “green space.” In order to assist physicians and mental health professionals in responding to patient and parent queries, this paper briefly describes these CAM therapies and current research regarding their effectiveness. While investigations in this area are hampered by research design issues such as sample size and the absence of double-blind placebo-controlled trials, there is some evidence that omega three fatty acids, zinc supplements, and neuro-feedback may have some efficacy. PMID:23762770
Viani, Alberto; Gualtieri, Alessandro F
2013-09-15
According to recent resolutions of the European Parliament (2012/2065(INI)), the need for environmentally friendly alternative solutions to landfill disposal of hazardous wastes, such as asbestos-containing materials, prompts their recycling as secondary raw materials (end of waste concept). In this respect, for the first time, we report the recycling of the high temperature product of cement-asbestos, in the formulation of calcium sulfoaluminate cement clinkers (novel cementitious binders designed to reduce CO₂ emissions), as a continuation of a previous work on their systematic characterization. Up to 29 wt% of the secondary raw material was successfully introduced into the raw mix. Different clinker samples were obtained at 1250 °C and 1300 °C, reproducing the phase composition of industrial analogues. As an alternative source of Ca and Si, this secondary raw material allows for a reduction of the CO₂ emissions in cement production, mitigating the ecological impact of cement manufacturing, and reducing the need for natural resources. Copyright © 2013 Elsevier B.V. All rights reserved.
Huang, Danni; Wang, Xianying; Deng, Chunhui; Song, Guoxin; Cheng, Hefa; Zhang, Xiangmin
2014-01-17
In this study, novel raisin-bread sandwich-structured magnetic graphene/mesoporous silica composites with C18-modified interior pore-walls (mag-graphene@mSiO2-C18) were synthesized by coating mesoporous silica layers onto each side of magnetic graphene through a surfactant-mediated co-condensation sol-gel process. The prepared functionalized nanocomposites possessed marvelous properties of extended plate-like morphology, fine water dispersibility, high magnetic response, large surface area (315.4cm(2)g(-1)), uniform pore size (3.3nm) and C18-modified interior pore-walls. Several kinds of phthalates were selected as model analytes to systematically evaluate the performance of adsorbents in extracting hydrophobic molecules followed by gas chromatography-mass spectrometry analyses. Various extraction parameters, including pH value of sample solution, amounts of adsorbents, adsorption time, species and volume of eluting solvent, and desorption time were optimized. The anti-interference ability to macromolecular proteins was also investigated. Method validations such as linearity, recovery, reproducibility, and limit of detection were also studied. Finally, mag-graphene@mSiO2-C18 composites were successfully applied to analyzing phthalates in environmental water samples. The results indicated that this novel approach offered an attractive alternative for rapid, convenient, efficient and selective magnetic solid-phase extraction for targeted hydrophobic compounds. Copyright © 2013 Elsevier B.V. All rights reserved.
Weekley, Claire M.; Aitken, Jade B.; Finney, Lydia; Vogt, Stefan; Witting, Paul K.; Harris, Hugh H.
2013-01-01
Determining the speciation of selenium in vivo is crucial to understanding the biological activity of this essential element, which is a popular dietary supplement due to its anti-cancer properties. Hyphenated techniques that combine separation and detection methods are traditionally and effectively used in selenium speciation analysis, but require extensive sample preparation that may affect speciation. Synchrotron-based X-ray absorption and fluorescence techniques offer an alternative approach to selenium speciation analysis that requires minimal sample preparation. We present a brief summary of some key HPLC-ICP-MS and ESI-MS/MS studies of the speciation of selenium in cells and rat tissues. We review the results of a top-down approach to selenium speciation in human lung cancer cells that aims to link the speciation and distribution of selenium to its biological activity using a combination of X-ray absorption spectroscopy (XAS) and X-ray fluorescence microscopy (XFM). The results of this approach highlight the distinct fates of selenomethionine, methylselenocysteine and selenite in terms of their speciation and distribution within cells: organic selenium metabolites were widely distributed throughout the cells, whereas inorganic selenium metabolites were compartmentalized and associated with copper. New data from the XFM mapping of electrophoretically-separated cell lysates show the distribution of selenium in the proteins of selenomethionine-treated cells. Future applications of this top-down approach are discussed. PMID:23698165
Foothills Parkway Section 8B Final Environmental Report, Volume 3, Appendix D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blasing, T.J.; Cada, G.F.; Carer, M.
1999-07-01
In 1994, Oak Ridge National Laboratory (ORNL) was tasked by the National Park Service (NPS) to prepare an Environmental Report (ER) for Section 8B of the Foothills Parkway in the Great Smoky Mountains National Park (GSMNP). Section 8B represents 27.7 km (14.2 miles) of a total of 115 km (72 miles) of the planned Foothills Parkway and would connect the Cosby community on the east to the incorporated town of Pittman Center to the west. The major deliverables for the project are listed. From August 1995 through October 1996, NPS, GSMNP, and ORNL staff interacted with Federal Highway Administration staffmore » to develop a conceptual design plan for Section 8B with the intent of protecting critical resources identified during the ER process to the extent possible. In addition, ORNL arranged for bioengineering experts to discuss techniques that might be employed on Section 8B with NPS, GSMNP, and ORNL staff during September 1996. For the purposes of this ER, there are two basic alternatives under consideration: (1) a build alternative and (2) a no-build alternative. Within the build alternative are a number of options including constructing Section 8B with no interchanges, constructing Section 8B with an interchange at SR416 or U.S. 321, constructing Section 8B with a spur road on Webb Mountain, and considering operation of Section 8B both before and after the operation of Section 8C. The no-build alternative is considered the no-action alternative and is not to construct Section 8B. This volume of the ER inventories the fishes and benthic macroinvertebrates inhabiting the aquatic ecosystems potentially affected by the proposed construction of Section 8B. Stream biological surveys were completed at 31 stream sites during the Fall of 1994. The sampling strategy for both invertebrates and fish was to survey the different taxa from all available habitats. For benthic invertebrates, a standardized qualitative manual collection technique was employed for all 31 stations. For fish, all streams of sufficient water were sampled using various methods of electroshocking. Two listed species were identified during the surveys: the Allegheny snaketail dragonfly (formerly a C2 federal candidate species found at six of the stream survey sites) and the tangerine darter (a Tennessee state special concern species found at two of the stream survey sites).« less
Carvalho, Ana P; Malcata, F Xavier
2005-06-29
Assays for fatty acid composition in biological materials are commonly carried out by gas chromatography, after conversion of the lipid material into the corresponding methyl esters (FAME) via suitable derivatization reactions. Quantitative derivatization depends on the type of catalyst and processing conditions employed, as well as the solubility of said sample in the reaction medium. Most literature pertinent to derivatization has focused on differential comparison between alternative methods; although useful to find out the best method for a particular sample, additional studies on factors that may affect each step of FAME preparation are urged. In this work, the influence of various parameters in each step of derivatization reactions was studied, using both cod liver oil and microalgal biomass as model systems. The accuracies of said methodologies were tested via comparison with the AOCS standard method, whereas their reproducibility was assessed by analysis of variance of (replicated) data. Alkaline catalysts generated lower levels of long-chain unsaturated FAME than acidic ones. Among these, acetyl chloride and BF(3) were statistically equivalent to each other. The standard method, which involves alkaline treatment of samples before acidic methylation with BF(3), provided equivalent results when compared with acidic methylation with BF(3) alone. Polarity of the reaction medium was found to be of the utmost importance in the process: intermediate values of polarity [e.g., obtained by a 1:1 (v/v) mixture of methanol with diethyl ether or toluene] provided amounts of extracted polyunsaturated fatty acids statistically higher than those obtained via the standard method.
Tseng, Wan-Chi; Chu, Shang-Ping; Kong, Po-Hsin; Huang, Chun-Kai; Chen, Jung-Hsuan; Chen, Pai-Shan; Huang, Shang-Da
2014-09-17
A sample preparation method, dispersive liquid-liquid microextraction assisted by an emulsion with low concentration of a surfactant in water and dispersed solvent coupled with gas chromatography-mass spectrometry, was developed for the analysis of the fungicides cyprodinil, procymidone, fludioxonil, flusilazole, benalaxyl, and tebuconazole in wine. A microsyringe was used to withdraw and discharge a mixture of extraction solvent and 240 μL of an aqueous solution of Triton X-100 (the dispersed agent) four times within 10 s to form a cloudy emulsion in the syringe. This emulsion was then injected into a 5 mL wine sample spiked with all of the above fungicides. The total extraction time was approximately 0.5 min. Under optimum conditions using 1-octanol (12 μL) as extraction solvent, the linear range of the method in analysis of all six fungicides was 0.05-100 μg L(-1), and the limit of detection ranged from 0.013 to 0.155 μg L(-1). The absolute recoveries (n = 3) and relative recoveries (n = 3) were 30-83 and 81-108% for white wine at 0.5, 5, and 5 μg L(-1), and 30-92 and 81-110% for red wine, respectively. The intraday (n = 7) and interday (n = 6) relative standard deviations ranged from 4.4 to 8.8% and from 4.3 to 11.2% at 0.5 μg L(-1), respectively. The method achieved high enrichment factors. It is an alternative sample preparation technique with good performance.
7 CFR 27.89 - Expenses; inspection; sampling.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Expenses; inspection; sampling. 27.89 Section 27.89... Micronaire § 27.89 Expenses; inspection; sampling. Expense of inspection and sampling, the preparation of the... Office, the expense of inspection, sampling, preparation of samples, and delivery of the samples to the...
7 CFR 27.89 - Expenses; inspection; sampling.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Expenses; inspection; sampling. 27.89 Section 27.89... Micronaire § 27.89 Expenses; inspection; sampling. Expense of inspection and sampling, the preparation of the... Office, the expense of inspection, sampling, preparation of samples, and delivery of the samples to the...
Pacheco, A M G; Freitas, M C; Baptista, M S; Vasconcelos, M T S D; Cabral, J P
2008-01-01
Samples of Platanus hybrida Brot. bark and Flavoparmelia caperata (L.) Hale thalli, from a clean area in northern Portugal (Baião), were transplanted into an exposure location at the south-western Atlantic coast, impacted by urban-industrial emissions (Sines), for a 10-month long experiment. Bark pieces were confined into nylon bags (2-mm mesh), and lichen thalli kept with their bark substrate (Pinus pinaster (Ait.) Sol.). Every two months, a double set of transplants (one for bark, one for lichens) was brought back into the laboratory, together with native samples of Evernia prunastri (L.) Ach. Following suitable cleansing and preparation procedures, field samples were put through INAA for elemental assessment. The results indicate that, regardless of signal magnitude, (1) concentrations in bark and lichen transplants are significantly correlated with atmospheric deposition for an appreciable number of elements; (2) there are a number of significant correlations between transplanted and native samples, and again between the latter and the deposition; and (3) the elements with biological patterns that follow the deposition in either transplanted or native samples (Co, V) are the very ones whose bioaccumulation seems to benefit from an alternation of wet-dry periods, which fits the precipitation record of the test site during the exposure term.
Van Loo, Ellen J; Babu, D; Crandall, Philip G; Ricke, Steven C
2012-06-01
Liquid smoke extracts have traditionally been used as flavoring agents, are known to possess antioxidant properties, and serve as natural alternatives to conventional antimicrobials. The antimicrobial efficacies of commercial liquid smoke samples may vary depending on their source and composition and the methods used to extract and concentrate the smoke. We investigated the MICs of eight commercial liquid smoke samples against Salmonella Enteritidis, Staphylococcus aureus, and Escherichia coli . The commercial liquid smoke samples purchased were supplied by the manufacturer as water-based or concentrated extracts of smoke from different wood sources. The MICs of the commercial smokes to inhibit the growth of foodborne pathogens ranged from 0.5 to 6.0% for E. coli, 0.5 to 8.0% for Salmonella, and 0.38 to 6% for S. aureus. The MIC for each liquid smoke sample was similar in its effect on both E. coli and Salmonella. Solvent-extracted antimicrobials prepared using pecan shells displayed significant differences between their inhibitory concentrations depending on the type of solvent used for extraction. The results indicated that the liquid smoke samples tested in this study could serve as effective natural antimicrobials and that their inhibitory effects depended more on the solvents used for extraction than the wood source.
Imaging Gallium Nitride High Electron Mobility Transistors to Identify Point Defects
2014-03-01
streamline the sample preparation procedure to maximize the yield of successful samples to be analyzed chemically in an energy dispersive spectrometry...transmission electron microscope (STEM), sample preparation 15. NUMBER OF PAGES 103 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT...Computer Engineering iii THIS PAGE INTENTIONALLY LEFT BLANK iv ABSTRACT The purpose of this thesis is to streamline the sample preparation
7 CFR 520.6 - Preparation of an Environmental Assessment (EA).
Code of Federal Regulations, 2011 CFR
2011-01-01
... commercial phase; (2) Field work having an impact on the local environment such as earth excavation... may have a significant environmental impact and thus warrant preparation of an EIS. The EA will... need for the project or other proposal, alternatives, environmental impacts of the proposed action and...
ERIC Educational Resources Information Center
Abu-Thabit, Nedal Y.
2016-01-01
Electrically conducting polymers are one of the promising alternative materials for technological applications in many interdisciplinary areas, including chemistry, material sciences, and engineering. This experiment was designed for providing undergraduate students with a quick and practical approach for preparation of a polyaniline-conducting…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
... because they partially overlap in their study areas, purpose, potential improvements, potential effects... that an EIS/EIR will be prepared to describe alternatives, potential environmental effects, and... funding toward flood management improvements. These funds may be matched with those from the Early...
Alternative Teacher Preparation Programs. Title II News You Can Use
ERIC Educational Resources Information Center
Office of Postsecondary Education, US Department of Education, 2015
2015-01-01
Title II of the "Higher Education Act of 1965" ("HEA"), as amended in 2008 by the "Higher Education Opportunity Act," requires states to report annually on key elements of their teacher preparation programs and requirements for initial teacher credentialing, kindergarten through 12th grade. "Title II News You Can…
Properties of cookies made with natural wax-vegetable oil organogels
USDA-ARS?s Scientific Manuscript database
Organogels prepared with a natural wax and a vegetable oil were examined as alternatives to a commercial margarine in cookie. To investigate effects of wax and vegetable oil on properties of cookie dough and cookies, organogels prepared from four different waxes including sunflower wax, rice bran wa...
Teacher Certification and Student Achievement
ERIC Educational Resources Information Center
Moss, Patricia Lewis
2012-01-01
The purpose of this mixed-method study was to determine if there is a significant difference between the achievement of students who are taught by traditionally prepared teachers and that of students who are taught by alternatively prepared teachers. The study further addressed the perspectives of both groups of teachers regarding selected…
USDA-ARS?s Scientific Manuscript database
Pre-emulsified fish oil supplements, an alternative to capsular triacylglycerol, may enhance the uptake of LCn3 fatty acids it contains. A randomized, Latin-square crossover design was used to compare the effects of four fish oil supplement preparations on phospholipid (PLFA) and chylomicron fatty ...
Preparing Early Childhood Special Educators in Appalachian Kentucky
ERIC Educational Resources Information Center
McLaren, Elizabeth; Rutland, Julie Harp
2013-01-01
National shortages of qualified personnel in the field of early childhood special education are well documented, with shortages magnified in regions characterized by poverty and rural geography. This article provides an overview of the challenges faced and innovations implemented by an alternate-track, personnel preparation program in Appalachian…
Hybridized Teacher Education Programs in NYC: A Missed Opportunity?
ERIC Educational Resources Information Center
Mungal, Angus Shiva
2015-01-01
This qualitative study describes the development of hybrid teacher preparation programs that emerged as a result of a "forced" partnership between university-based and alternative teacher preparation programs in New York City. This hybrid experiment was a short-lived, yet innovative by-product of a somewhat pragmatic arrangement between…
Gavioli, Elena; Maier, Norbert M; Minguillón, Cristina; Lindner, Wolfgang
2004-10-01
A countercurrent chromatography protocol for support-free preparative enantiomer separation of the herbicidal agent 2-(2,4-dichlorphenoxy)propionic acid (dichlorprop) was developed utilizing a purposefully designed, highly enantioselective chiral stationary-phase additive (CSPA) derived from bis-1,4-(dihydroquinidinyl)phthalazine. Guided by liquid-liquid extraction experiments, a solvent system consisting of 10 mM CSPA in methyl tert-butyl ether and 100 mM sodium phosphate buffer (pH 8.0) was identified as a suitable stationary/mobile-phase combination. This solvent system provided an ideal compromise among stationary-phase retention, enantioselectivity, and well-balanced analyte distribution behavior. Using a commercial centrifugal partition chromatography instrument, complete enantiomer separations of up to 366 mg of racemic dichlorprop could be achieved, corresponding to a sample load being equivalent to the molar amount of CSPA employed. Comparison of the preparative performance characteristics of the CPC protocol with that of a HPLC separation using a silica-supported bis-1,4-(dihydroquinidinyl)phthalazine chiral stationary phase CSP revealed comparable loading capacities for both techniques but a significantly lower solvent consumption for CPC. With respect to productivity, HPLC was found to be superior, mainly due to inherent flow rate restrictions of the CPC instrument. Given that further progress in instrumental design and engineering of dedicated, highly enantioselective CSPAs can be achieved, CPC may offer a viable alternative to CSP-based HPLC for preparative-scale enantiomer separation.
Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda
2018-01-01
Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653
High-throughput automated microfluidic sample preparation for accurate microbial genomics
Kim, Soohong; De Jonghe, Joachim; Kulesa, Anthony B.; Feldman, David; Vatanen, Tommi; Bhattacharyya, Roby P.; Berdy, Brittany; Gomez, James; Nolan, Jill; Epstein, Slava; Blainey, Paul C.
2017-01-01
Low-cost shotgun DNA sequencing is transforming the microbial sciences. Sequencing instruments are so effective that sample preparation is now the key limiting factor. Here, we introduce a microfluidic sample preparation platform that integrates the key steps in cells to sequence library sample preparation for up to 96 samples and reduces DNA input requirements 100-fold while maintaining or improving data quality. The general-purpose microarchitecture we demonstrate supports workflows with arbitrary numbers of reaction and clean-up or capture steps. By reducing the sample quantity requirements, we enabled low-input (∼10,000 cells) whole-genome shotgun (WGS) sequencing of Mycobacterium tuberculosis and soil micro-colonies with superior results. We also leveraged the enhanced throughput to sequence ∼400 clinical Pseudomonas aeruginosa libraries and demonstrate excellent single-nucleotide polymorphism detection performance that explained phenotypically observed antibiotic resistance. Fully-integrated lab-on-chip sample preparation overcomes technical barriers to enable broader deployment of genomics across many basic research and translational applications. PMID:28128213
Behavior of Aluminum in Solid Propellant Combustion
1982-06-01
dry pressing 30% Valley Met H- 30 aluminum, 7% carnauba wax , and 63% 100 P AP. One sample was prepared using as received H-30, a second sample used pre...34propellant" formulations. The formulations included dry pressed AP/AI, and AP/AI/ Wax samples. Sandwiches were also prepared consisting of an aluminum...Binder flame instead of by aluminum exposure during accumulate break-up. Combustion of AP/AI/ Wax Samples A set of propellant samples were prepared by
Bonta, Maximilian; Török, Szilvia; Hegedus, Balazs; Döme, Balazs; Limbeck, Andreas
2017-03-01
Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is one of the most commonly applied methods for lateral trace element distribution analysis in medical studies. Many improvements of the technique regarding quantification and achievable lateral resolution have been achieved in the last years. Nevertheless, sample preparation is also of major importance and the optimal sample preparation strategy still has not been defined. While conventional histology knows a number of sample pre-treatment strategies, little is known about the effect of these approaches on the lateral distributions of elements and/or their quantities in tissues. The technique of formalin fixation and paraffin embedding (FFPE) has emerged as the gold standard in tissue preparation. However, the potential use for elemental distribution studies is questionable due to a large number of sample preparation steps. In this work, LA-ICP-MS was used to examine the applicability of the FFPE sample preparation approach for elemental distribution studies. Qualitative elemental distributions as well as quantitative concentrations in cryo-cut tissues as well as FFPE samples were compared. Results showed that some metals (especially Na and K) are severely affected by the FFPE process, whereas others (e.g., Mn, Ni) are less influenced. Based on these results, a general recommendation can be given: FFPE samples are completely unsuitable for the analysis of alkaline metals. When analyzing transition metals, FFPE samples can give comparable results to snap-frozen tissues. Graphical abstract Sample preparation strategies for biological tissues are compared with regard to the elemental distributions and average trace element concentrations.
Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software
GIANNASTASIO, Daiana; da ROSA, Ricardo Abreu; PERES, Bernardo Urbanetto; BARRETO, Mirela Sangoi; DOTTO, Gustavo Nogara; KUGA, Milton Carlos; PEREIRA, Jefferson Ricardo; SÓ, Marcus Vinícius Reis
2013-01-01
Objective This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Material and Methods Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. Results The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Conclusion Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop. PMID:24212994
Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software.
Giannastasio, Daiana; Rosa, Ricardo Abreu da; Peres, Bernardo Urbanetto; Barreto, Mirela Sangoi; Dotto, Gustavo Nogara; Kuga, Milton Carlos; Pereira, Jefferson Ricardo; Só, Marcus Vinícius Reis
2013-01-01
This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.
Resident cross-cultural training, satisfaction, and preparedness.
Frintner, Mary Pat; Mendoza, Fernando S; Dreyer, Benard P; Cull, William L; Laraque, Danielle
2013-01-01
To describe the diversity of pediatric residents and examine relationships of cross-cultural training experiences with training satisfaction, perceived preparedness for providing culturally effective care, and attitudes surrounding care for underserved populations. A cross-sectional survey was conducted of a national random sample of graduating pediatric residents and an additional sample of minority residents. Using weighted analysis, we used multivariate regression to test for differences in satisfaction, preparedness, and attitudes between residents with more and less cross-cultural experiences during residency, controlling for residents' characteristics and experiences before training. The survey response rate was 57%. Eleven percent were Hispanic, 61% white, 21% Asian, 9% African American, 9% other racial/ethnic groups; 34% grew up in a bi- or multilingual family. Ninety-three percent of residents were satisfied with their residency training, 81% with the instruction they received on health and health care disparities, and 54% on global health issues. Ninety-six percent of residents felt they were prepared to care for patients from diverse backgrounds, but fewer felt prepared to care for families with beliefs at odds with Western medicine (49%) and families who receive alternative or complementary care (37%). Residents with more cross-cultural experiences during residency reported being better prepared than those with less experience to care for families with limited English proficiency (adjusted odds ratio [aOR] 2.11; 95% confidence interval [CI] 1.40-3.17), new immigrants (aOR 1.91; 95% CI 1.32-2.75), and with religious beliefs that might affect clinical care (aOR 1.62; 95% CI 1.13-2.32). Pediatric residents begin their training with diverse cross-cultural backgrounds and experiences. Residency experiences in cross-cultural care contribute to feelings of preparedness to care for diverse US children. Copyright © 2013 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Long-term high-level waste technology. Composite report
NASA Astrophysics Data System (ADS)
Cornman, W. R.
1981-12-01
Research and development studies on the immobilization of high-level wastes from the chemical reprocessing of nuclear reactor fuels are summarized. The reports are grouped under the following tasks: (1) program management and support; (2) waste preparation; (3) waste fixation; and (4) final handling. Some of the highlights are: leaching properties were obtained for titanate and tailored ceramic materials being developed at ICPP to immobilize zirconia calcine; comparative leach tests, hot-cell tests, and process evaluations were conducted of waste form alternatives to borosilicate glass for the immobilization of SRP high-level wastes, experiments were run at ANL to qualify neutron activation analysis and radioactive tracers for measuring leach rates from simulated waste glasses; comparative leach test samples of SYNROC D were prepared, characterized, and tested at LLNL; encapsulation of glass marbles with lead or lead alloys was demonstrated on an engineering scale at PNL; a canister for reference Commercial HLW was designed at PNL; a study of the optimization of salt-crete was completed at SRL; a risk assessment showed that an investment for tornado dampers in the interim storage building of the DWPF is unjustified.
[The photoluminescence characteristics of organic multilayer quantum wells].
Zhao, De-Wei; Song, Shu-Fang; Zhao, Su-Ling; Xu, Zheng; Wang, Yong-Sheng; Xu, Xu-Rong
2007-04-01
By the use of multi-source high-vaccum organic beam deposition system, the authors prepared organic multilayer quantum well structures, which consist of alternate organic small molecule materials PBD and Alq3. Based on 4-period organic quantum wells, different samples with different thickness barriers and wells were prepared. The authors measured the lowest unoccupied molecular orbit (LUMO) and the highest occupied molecular orbit (HOMO) by electrochemistry cyclic voltammetry and optical absorption. From the energy diagrams, it seems like type-I quantum well structures of the inorganic semiconductor, in which PBD is used as a barrier layer and Alq3 as a well layer and emitter. From small angle X-ray diffraction measurements, the results indicate that these structures have high interface quality and uniformity. The photoluminescence characteristics of organic multilayer quantum wells were investigated. The PL peak has a blue-shift with the decrease of the well layer thickness. Meanwhile as the barrier thickness decreases the PL peaks of PBD disappear gradually. And the energy may be effectively transferred from PBD to Alq3, inducing an enhancement of the luminescence of Alq3.
NASA Astrophysics Data System (ADS)
Saputri, Apriliana Eka; Praseptiangga, Danar; Rochima, Emma; Panatarani, Camellia; Joni, I. Made
2018-02-01
The aim of this present work is to develop semi refined kappa carrageenan based bio-nanocomposite film as an alternative to synthetic petroleum based food packaging materials. Among natural polymers, carrageenan is one of the most promising material, since it is a renewable bioresource. The ZnO nanoparticles (0.5%; 1.0%; 1.5% w/w carrageenan) was incorporated into carrageenan polymer to prepare bio-nanocomposite films, where ZnO acts as reinforcement for carrageenan matrix. The mechanical and solubility properties of the prepared films were investigated as a function of ZnO concentration. The results indicated that the addition of ZnO exhibits greater solubility compared to the neat film. The elongation at break is insignificantly different on the films with and without addition ZnO. The tensile strength of the film was highest for the sample with 0.5% ZnO. These mechanical and solubility properties suggest that bio-nanocomposite film of semi refined kappa carrageenan and nanoparticle ZnO can be effectively used as food packaging material.
Electrical and Infrared Optical Properties of Vanadium Oxide Semiconducting Thin-Film Thermometers
NASA Astrophysics Data System (ADS)
Zia, Muhammad Fakhar; Abdel-Rahman, Mohamed; Alduraibi, Mohammad; Ilahi, Bouraoui; Awad, Ehab; Majzoub, Sohaib
2017-10-01
A synthesis method has been developed for preparation of vanadium oxide thermometer thin film for microbolometer application. The structure presented is a 95-nm thin film prepared by sputter-depositing nine alternating multilayer thin films of vanadium pentoxide (V2O5) with thickness of 15 nm and vanadium with thickness of 5 nm followed by postdeposition annealing at 300°C in nitrogen (N2) and oxygen (O2) atmospheres. The resulting vanadium oxide (V x O y ) thermometer thin films exhibited temperature coefficient of resistance (TCR) of -3.55%/°C with room-temperature resistivity of 2.68 Ω cm for structures annealed in N2 atmosphere, and TCR of -3.06%/°C with room-temperature resistivity of 0.84 Ω cm for structures annealed in O2 atmosphere. Furthermore, optical measurements of N2- and O2-annealed samples were performed by Fourier-transform infrared ellipsometry to determine their dispersion curves, refractive index ( n), and extinction coefficient ( k) at wavelength from 7000 nm to 14,000 nm. The results indicate the possibility of applying the developed materials in thermometers for microbolometers.
Preparation of Chemical Samples On Relevant Surfaces Using Inkjet Technology
2013-04-01
PREPARATION OF CHEMICAL SAMPLES ON RELEVANT SURFACES USING INKJET TECHNOLOGY...2012 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Preparation of Chemical Samples on Relevant Surfaces Using Inkjet Technology 5b. GRANT NUMBER...SUBJECT TERMS Surface detection Inkjet Simulant deposition 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF
NASA Astrophysics Data System (ADS)
Suyanto, Hery; Lie, Tjung Jie; Kurniawan, Koo Hendrik; Kagawa, Kiichiro; Tjia, May On
2017-11-01
A practical alternative of sample preparation technique is proposed for direct powder analysis using laser-induced breakdown spectroscopy (LIBS) instead of the commonly adopted treatment of pelletizing the powder. The resulted pellet is known to suffer from reduced sensitivity of emission. Besides, it may also give rise to interfering effect from the binder emission. We introduce in this report a more practical technique of using a subtarget supported micro mesh (SSMM) powder sample holder. The LIBS spectrum of standard soil powder measured with 13 mJ 1064 nm Nd:YAG laser in 0.65 kPa ambient air is shown to exhibit the sharp emission lines of all the major elements in the sample. A comparison with the emission spectra measured from the pelletized powder, the spectrum obtained using the SSMM sample holder shows distinctly superior spectral quality marked by the absence of matrix effect found in pelletized powder samples, and the much stronger intensity due to the more effective shock wave plasma induced thermal excitation process produced by the hard subtarget in the sample holder. Repeating the measurement on a number of the standard soil samples of various Pb contents is shown to yield a linear calibration line with practically zero intercept and a detection limit of less than 10 ppm. We have thus demonstrated the viability of the proposed powder sample holder for the development of practical and quantitative powder analysis in the field.
Use Of The Diamond Cell In An Industrial Laboratory
NASA Astrophysics Data System (ADS)
Barbour, Rachael L.; Stephens, J. D.; Cameron, David G.
1989-12-01
The traditional method for recording the IR spectra of solids has been KBr pellet transmission spectroscopy. This technique has several disadvantages: sample preparation time, matrix contamination, spectral distortion, ion exchange, a limited spectral range, scattering, loss of sample integrity during grinding, etc. In recent years, diffuse reflectance, ATR, photoacoustic reflectance, and external reflectance have been used increasingly, facilitated by the high SNR of FT instruments. In many cases, the diamond cell is an attractive alternative to all of these. The spectral range is -100 -1 to the UV, excluding the 2200-2000 cm -1 region. Spectral distortion, usually a great problem with inorganics, is greatly reduced as a result of sample homogeneity (from a spectral point of view) and refractive index matching. There is no matrix contamination: scattering, background slope, and all absorption bands are from the sample. There is no ion exchange. The sample size requirements are minimal. Finally, sample preparation requires the somewhat lost. but powerful, art of microscopic examination. In some instances, there may be sample orientation or pressure induced phase changes associated with the use of the diamond cell. A common misconception is that an IR microscope is needed to use the diamond cell. In fact, ~5 minutes will suffice without a beam condenser; 1 minute is all that is needed with one. In part, this is because one usually has excellent control of the optical thickness; with experience, the cell can easily be assembled to give bands in the 0.7-1.5 absorbance range, and making the sample thinner merely involves pressing the diamonds together. Given the above, the microscope should only be used for inhomogeneous samples as one loses all information below 700 cm-1, the region of greatest value when studying inorganics. We also note that the cell can readily be moved from a mid-IR to a far-IR bench. We have moved to the point where this is the dominant sampling technique, with ATR being the next most important. Diffuse reflectance and KBr pellets are seldom used. The cell has been used on inorganics (mid and far IR) including extremely small pure mineral samples selected by hand. It is also used for polymers, polymer inclusions, filter deposits, pure (and not so puce) organics, and general "what is this stuff" samples. Examples of a wide variety of analyses will be given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takayama, Yuki; Nakasako, Masayoshi; RIKEN Harima Institute/SPring-8, 1-1-1 Kouto, Mikaduki, Sayo, Hyogo 679-5148
2012-05-15
Coherent x-ray diffraction microscopy (CXDM) has the potential to visualize the structures of micro- to sub-micrometer-sized biological particles, such as cells and organelles, at high resolution. Toward advancing structural studies on the functional states of such particles, here, we developed a system for the preparation of frozen-hydrated biological samples for cryogenic CXDM experiments. The system, which comprised a moist air generator, microscope, micro-injector mounted on a micromanipulator, custom-made sample preparation chamber, and flash-cooling device, allowed for the manipulation of sample particles in the relative humidity range of 20%-94%rh at 293 K to maintain their hydrated and functional states. Here, wemore » report the details of the system and the operation procedure, including its application to the preparation of a frozen-hydrated chloroplast sample. Sample quality was evaluated through a cryogenic CXDM experiment conducted at BL29XUL of SPring-8. Taking the performance of the system and the quality of the sample, the system was suitable to prepare frozen-hydrated biological samples for cryogenic CXDM experiments.« less
Preparation of bone samples in the Gliwice Radiocarbon Laboratory for AMS radiocarbon dating.
Piotrowska, N; Goslar, T
2002-12-01
In the Gliwice Radiocarbon Laboratory, a system for preparation of samples for AMS dating has been built. At first it was used to produce graphite targets from plant macrofossils and sediments. In this study we extended its capabilities with the preparation of bones. We dealt with 3 methods; the first was the classical Longin method of collagen extraction, the second one included additional treatment of powdered bone in alkali solution, while in the third one carboxyl carbon was separated from amino acids obtained after hydrolysis of protein. The suitability of the methods was tested on 2 bone samples. Most of our samples gave ages > 40 kyr BP, suggesting good performance of the adapted methods, except for one sample prepared with simple Longin method. For routine preparation of bones we chose the Longin method with additional alkali treatment.
Effect Of Neodymium Substitution In Structural Characteristics Of Magnesium Ferrite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thankachan, Smitha; Binu, P. J.; Xavier, Sheena
2011-10-20
The effect of Nd{sup 3+} substitution on the structural properties of Magnesium ferrite was studied in the series MgNd{sub x}Fe{sub 2-x}O{sub 4}, where x = 0 to 0.3 in steps of 0.05. The series was prepared by sol-gel technique which is one of the novel technique to prepare nanosized samples. Structural characterization was done using X-ray diffractometer and Fourier Transform Infrared Spectrometer. XRD analysis reveals the prepared samples are single phasic till x = 0.2. From x0 = .25, a secondary phase of iron neodymium oxide appears along with the spinel phase. Particle size calculation shows the prepared samples aremore » in the 9nm to 11 nm regime. Lattice parameter was found to increase with concentration of Nd. XRD and FTIR analysis confirmed spinel structure of the prepared samples. XRF result shows the expected composition of prepared samples. The frequency dependence of the dielectric constant in the range 100 Hz--120MHz was also studied« less
NASA Astrophysics Data System (ADS)
Shen, Peichuan
In recent decades, semiconductor photocatalysis has attracted a growing attention as a possible alternative to existing methods of hydrogen production, hydrocarbon conversion and organic compound oxidation. Many types of photocatalysts have been developed and tested for photocatalytic applications. However, most of them do not have notable activity in visible light region, which limits their practical applications. Development of photocatalysts, which can be activated by visible light provides a promising way forward to utilize both UV and visible portions of solar spectrum. In this thesis, two main methods to advance visible light driven photocatalysis, such as bandgap modification through doping and co-catalyst development, are investigated. The photocatalysts studied in this thesis included CdS and SrTiO3, which were extensively investigated and characterized. Rhodium doped strontium titanate was synthesized through different preparation methods. The synthesized samples have been investigated by various characterization techniques including XRD, TEM, STEM, XPS and UV-Vis spectroscopy. The effect of preparation conditions, such as doping concentration, calcination temperature and pH have been investigated and optimized. In addition, the photocatalytic activities for hydrogen production of the samples synthesized by different preparation methods were also studied. Among the preparation methods, polymerizable complex (PC) method was found to be the most effective synthesis method for SrTiO3: Rh. The samples prepared by PC method had higher photocatalytic activity as compared to that of samples synthesized by solid state reaction method and hydrothermal method. The reasons might be attributed to more effective doping and higher surface area. The results of this work suggest that PC method can also be applied to develop other perovskite materials for photocatalytic applications. Co-catalyst development for enhancement of photocatalytic hydrogen production is also described in this dissertation. Noble metal nanoparticles have been proved to be effective co-catalysts due to their unique physical and chemical properties. Au and Pt nanoparticles with different sizes were synthesized and deposited on CdS. Sub-nanometer Au and Pt were found to be promising co-catalysts for photocatalytic hydrogen production reaction. Specifically, sub-nm Au and sub-nm Pt nanoparticles were found to enhance the photocatalytic activity in hydrogen production of CdS by 35 and 15 times respectively. Other noble metal co-catalysts, such as Ru, Pd and Rh were also deposited on CdS and their photocatalytic activities were investigated. Additionally, a novel chamber for photocatalytic reactions was developed as a part of this dissertation. The reaction chamber has several unique features allowing different reactions and measurements. The reactor was proved to be suitable for future projects in photocatalysis such as photocatalytic CO2 conversion into hydrocarbons.
Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M
2006-01-01
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
Round robin test on quantification of amyloid-β 1-42 in cerebrospinal fluid by mass spectrometry.
Pannee, Josef; Gobom, Johan; Shaw, Leslie M; Korecka, Magdalena; Chambers, Erin E; Lame, Mary; Jenkins, Rand; Mylott, William; Carrillo, Maria C; Zegers, Ingrid; Zetterberg, Henrik; Blennow, Kaj; Portelius, Erik
2016-01-01
Cerebrospinal fluid (CSF) amyloid-β 1-42 (Aβ42) is an important biomarker for Alzheimer's disease, both in diagnostics and to monitor disease-modifying therapies. However, there is a great need for standardization of methods used for quantification. To overcome problems associated with immunoassays, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as a critical orthogonal alternative. We compared results for CSF Aβ42 quantification in a round robin study performed in four laboratories using similar sample preparation methods and LC-MS instrumentation. The LC-MS results showed excellent correlation between laboratories (r(2) >0.98), high analytical precision, and good correlation with enzyme-linked immunosorbent assay (r(2) >0.85). The use of a common reference sample further decreased interlaboratory variation. Our results indicate that LC-MS is suitable for absolute quantification of Aβ42 in CSF and highlight the importance of developing a certified reference material. Copyright © 2016 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
EASI-IMS an expedite and secure technique to screen for 25I-NBOH in blotter papers.
de Morais, Damila Rodrigues; Barbosa, Ingrid Lopes; Cunha, Kelly Francisco; Tripodi, Guilherme Lucas; Angolini, Célio Fernando Figueiredo; Franco, Marcos Fernando; de Aquino, Elvis Medeiros; Eberlin, Marcos Nogueira; Costa, Jose Luiz
2017-10-01
The increasing number of new psychoactive substances (NPS) and their quick worldwide spreading, often only slightly modified in the form of new derivatives and analogues, have brought the need for fast, wide-ranging, and unequivocal identification methods in clinical and forensic investigations. Because it usually provides secure results, gas chromatography coupled to mass spectrometry (GC-MS) has been routinely employed as the standard technique for the detection of NPS in blotter papers. For 25I-NBOH (N-(2-hydroxybenzyl)-2-(4-iodo-2,5-dimethoxyphenyl)ethan-1-aminium), however, GC-MS analysis of an blotter paper extract leads to incorrect results. In this work, we investigated whether easy ambient sonic-spray mass spectrometry imaging (EASI-IMS), and ambient ionization MS method can be applied directly to the surface of the sample requiring therefore no extraction or sample preparations, would serve as an efficient, sensitive, and secure alternative for 25I-NBOH screening. Copyright © 2017 John Wiley & Sons, Ltd.
McMullin, David; Mizaikoff, Boris; Krska, Rudolf
2015-01-01
Infrared spectroscopy is a rapid, nondestructive analytical technique that can be applied to the authentication and characterization of food samples in high throughput. In particular, near infrared spectroscopy is commonly utilized in the food quality control industry to monitor the physical attributes of numerous cereal grains for protein, carbohydrate, and lipid content. IR-based methods require little sample preparation, labor, or technical competence if multivariate data mining techniques are implemented; however, they do require extensive calibration. Economically important crops are infected by fungi that can severely reduce crop yields and quality and, in addition, produce mycotoxins. Owing to the health risks associated with mycotoxins in the food chain, regulatory limits have been set by both national and international institutions for specific mycotoxins and mycotoxin classes. This article discusses the progress and potential of IR-based methods as an alternative to existing chemical methods for the determination of fungal contamination in crops, as well as emerging spectroscopic methods.
Simplified multi-element analysis of ground and instant coffees by ICP-OES and FAAS.
Szymczycha-Madeja, Anna; Welna, Maja; Pohl, Pawel
2015-01-01
A simplified alternative to the wet digestion sample preparation procedure for roasted ground and instant coffees has been developed and validated for the determination of different elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (Al, Ba, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sr, Zn) and flame atomic absorption spectrometry (FAAS) (Ca, Fe, K, Mg, Na). The proposed procedure, i.e. the ultrasound-assisted solubilisation in aqua regia, is quite fast and simple, requires minimal use of reagents, and demonstrated good analytical performance, i.e. accuracy from -4.7% to 1.9%, precision within 0.5-8.6% and recovery in the range 93.5-103%. Detection limits of elements were from 0.086 ng ml(-1) (Sr) to 40 ng ml(-1) (Fe). A preliminary classification of 18 samples of ground and instant coffees was successfully made based on concentrations of selected elements and using principal component analysis and hierarchic cluster analysis.
Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai
2017-01-01
A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.
Environmental Scanning Electron Microscope Imaging of Vesicle Systems.
Perrie, Yvonne; Ali, Habib; Kirby, Daniel J; Mohammed, Afzal U R; McNeil, Sarah E; Vangala, Anil
2017-01-01
The structural characteristics of liposomes have been widely investigated and there is certainly a strong understanding of their morphological characteristics. Imaging of these systems, using techniques such as freeze-fracturing methods, transmission electron microscopy, and cryo-electron imaging, has allowed us to appreciate their bilayer structures and factors which can influence this. However, there are few methods which all us to study these systems in their natural hydrated state; commonly the liposomes are visualized after drying, staining, and/or fixation of the vesicles. Environmental Scanning Electron Microscopy (ESEM) offers the ability to image a liposome in its hydrated state without the need for prior sample preparation. Within our studies we were the first to use ESEM to study liposomes and niosomes and we have been able to dynamically follow the hydration of lipid films and changes in liposome suspensions as water condenses on to, or evaporates from, the sample in real time. This provides insight into the resistance of liposomes to coalescence during dehydration, thereby providing an alternative assay of liposome formulation and stability.
NASA Astrophysics Data System (ADS)
Hattan, Stephen J.; Parker, Kenneth C.; Vestal, Marvin L.; Yang, Jane Y.; Herold, David A.; Duncan, Mark W.
2016-03-01
Measurement of glycated hemoglobin is widely used for the diagnosis and monitoring of diabetes mellitus. Matrix assisted laser desorption/ionization (MALDI) time of flight (TOF) mass spectrometry (MS) analysis of patient samples is used to demonstrate a method for quantitation of total glycation on the β-subunit of hemoglobin. The approach is accurate and calibrated with commercially available reference materials. Measurements were linear (R2 > 0.99) across the clinically relevant range of 4% to 20% glycation with coefficients of variation of ≤ 2.5%. Additional and independent measurements of glycation of the α-subunit of hemoglobin are used to validate β-subunit glycation measurements and distinguish hemoglobin variants. Results obtained by MALDI-TOF MS were compared with those obtained in a clinical laboratory using validated HPLC methodology. MALDI-TOF MS sample preparation was minimal and analysis times were rapid making the method an attractive alternative to methodologies currently in practice.
Application Prospects of Multilayer Film Shields for Space Research Instrumentation
NASA Astrophysics Data System (ADS)
Nyunt, P. W.; Vlasik, K. F.; Grachev, V. M.; Dmitrenko, V. V.; Novikov, A. S.; Petrenko, D. V.; Ulin, S. E.; Uteshev, Z. M.; Chernysheva, I. V.; Shustov, A. E.
We have studied the magnetic properties of multilayer film cylindrical configuration shields (MFS) based on NiFe / Cu. The studied samples were prepared by electrode position. MFS were constituted by alternating layers of NiFe and Cu, deposited on an aluminum cylinder with diameter of 4 cm, length of 13 cm and 0.5 cm thickness. The thickness of each ferromagnetic layer varied from 10 to 150 μm, and the thickness of Cu layers was 5 μm. Five-samples in which the number of ferromagnetic layers varied from 3 to 45 and copper - from 2 to 44 were tested. The best shielding efficiency was achieved at the maximum number of layers and comprised about 102. Permalloy multilayer foil shield at the same total thickness has several times less efficiency in comparison with MFS. The description of a prototype of the charged particles telescope for space application is presented. Results of its testing regarding sensitivity to the constant magnetic field are described.
Patterson, Joseph P.; Sanchez, Ana M.; Petzetakis, Nikos; Smart, Thomas P.; Epps, Thomas H.; Portman, Ian
2013-01-01
Block copolymers are well-known to self-assemble into a range of 3-dimensional morphologies. However, due to their nanoscale dimensions, resolving their exact structure can be a challenge. Transmission electron microscopy (TEM) is a powerful technique for achieving this, but for polymeric assemblies chemical fixing/staining techniques are usually required to increase image contrast and protect specimens from electron beam damage. Graphene oxide (GO) is a robust, water-dispersable, and nearly electron transparent membrane: an ideal support for TEM. We show that when using GO supports no stains are required to acquire high contrast TEM images and that the specimens remain stable under the electron beam for long periods, allowing sample analysis by a range of electron microscopy techniques. GO supports are also used for further characterization of assemblies by atomic force microscopy. The simplicity of sample preparation and analysis, as well as the potential for significantly increased contrast background, make GO supports an attractive alternative for the analysis of block copolymer assemblies. PMID:24049544
NASA Astrophysics Data System (ADS)
Duarte, C. L.; Ribeiro, M. A.; Oikawa, H.; Mori, M. N.; Napolitano, C. M.; Galvão, C. A.
2012-08-01
The use of microbial cellulolytic enzymes is the most efficient process to liberate glucose from cellulose in biomass without the formation of fermentation inhibitors. A combination of pretreatment technologies is an alternative way to increase the access of enzymes to cellulose, and consequently, the conversion yield. In this way, the present study reports on the enzymatic hydrolysis of SCB submitted to three kinds of pretreatment: electron beam processing (EBP), and EBP followed by hydrothermal (TH) and diluted acid (AH) treatment. SCB samples were irradiated using a radiation dynamics electron beam accelerator, and then submitted to thermal and acid (0.1% sulfuric acid) hydrolysis for 40 and 60 min at 180 °C. These samples were submitted to enzymatic hydrolysis (EH) using commercial preparations, including Celluclast 1.5 L and beta-glycosidase. The addition of diluted acid improved TH treatment allowing for a shorter application time. EBP with 50 kGy increased the enzymatic hydrolysis yield of cellulose by 20% after TH and 30% after AH.
Integrated electrochemical microsystems for genetic detection of pathogens at the point of care.
Hsieh, Kuangwen; Ferguson, B Scott; Eisenstein, Michael; Plaxco, Kevin W; Soh, H Tom
2015-04-21
The capacity to achieve rapid, sensitive, specific, quantitative, and multiplexed genetic detection of pathogens via a robust, portable, point-of-care platform could transform many diagnostic applications. And while contemporary technologies have yet to effectively achieve this goal, the advent of microfluidics provides a potentially viable approach to this end by enabling the integration of sophisticated multistep biochemical assays (e.g., sample preparation, genetic amplification, and quantitative detection) in a monolithic, portable device from relatively small biological samples. Integrated electrochemical sensors offer a particularly promising solution to genetic detection because they do not require optical instrumentation and are readily compatible with both integrated circuit and microfluidic technologies. Nevertheless, the development of generalizable microfluidic electrochemical platforms that integrate sample preparation and amplification as well as quantitative and multiplexed detection remains a challenging and unsolved technical problem. Recognizing this unmet need, we have developed a series of microfluidic electrochemical DNA sensors that have progressively evolved to encompass each of these critical functionalities. For DNA detection, our platforms employ label-free, single-step, and sequence-specific electrochemical DNA (E-DNA) sensors, in which an electrode-bound, redox-reporter-modified DNA "probe" generates a current change after undergoing a hybridization-induced conformational change. After successfully integrating E-DNA sensors into a microfluidic chip format, we subsequently incorporated on-chip genetic amplification techniques including polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) to enable genetic detection at clinically relevant target concentrations. To maximize the potential point-of-care utility of our platforms, we have further integrated sample preparation via immunomagnetic separation, which allowed the detection of influenza virus directly from throat swabs and developed strategies for the multiplexed detection of related bacterial strains from the blood of septic mice. Finally, we developed an alternative electrochemical detection platform based on real-time LAMP, which not is only capable of detecting across a broad dynamic range of target concentrations, but also greatly simplifies quantitative measurement of nucleic acids. These efforts represent considerable progress toward the development of a true sample-in-answer-out platform for genetic detection of pathogens at the point of care. Given the many advantages of these systems, and the growing interest and innovative contributions from researchers in this field, we are optimistic that iterations of these systems will arrive in clinical settings in the foreseeable future.
Are friends electric?: A review of the electric handpiece in clinical dental practice.
Campbell, Stuart C
2013-04-01
Contemporary restorative procedures demand precise detail in tooth preparation to achieve optimal results. Inadequate tooth preparation is a frequent cause of failure. This review considers the electric high-speed, high-torque handpiece and how it may assist clinicians in achieving greater accuracy in tooth preparation. The electric handpiece provides a satisfactory alternative to the air-turbine and may be considered by clinicians who wish greater control with operative procedures.
A Facile Preparation of Imidazolinium Chlorides
Kuhn, Kevin M.; Grubbs, Robert H.
2009-01-01
A process for the preparation of symmetric and unsymmetric imidazolinium chlorides that involves reaction of a formamidine with dichloroethane and a base (a) is described. This method makes it possible to obtain numerous imidazolinium chlorides under solvent-free reaction conditions and in excellent yields with purification by simple filtration. Alternatively, symmetric imidazolinium chlorides can be prepared directly in moderate yields from substituted anilines by utilizing half of the formamidine intermediate as sacrificial base (b). PMID:18412354
Recent advances of mesoporous materials in sample preparation.
Zhao, Liang; Qin, Hongqiang; Wu, Ren'an; Zou, Hanfa
2012-03-09
Sample preparation has been playing an important role in the analysis of complex samples. Mesoporous materials as the promising adsorbents have gained increasing research interest in sample preparation due to their desirable characteristics of high surface area, large pore volume, tunable mesoporous channels with well defined pore-size distribution, controllable wall composition, as well as modifiable surface properties. The aim of this paper is to review the recent advances of mesoporous materials in sample preparation with emphases on extraction of metal ions, adsorption of organic compounds, size selective enrichment of peptides/proteins, specific capture of post-translational peptides/proteins and enzymatic reactor for protein digestion. Copyright © 2011 Elsevier B.V. All rights reserved.
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 761.323 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the...
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 761.323 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the...
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 761.323 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the...
NASA Astrophysics Data System (ADS)
Sydoff, Marie; Stenström, Kristina
2010-04-01
The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.
Postmining land use: economic comparison of forestry and pastureland alternatives
Charles H. Wolf
1980-01-01
The influence of soil properties, legal requirements, and economics on postmining land use is described, and enterprise budgets are prepared to demonstrate procedures for evaluating forest and pastureland alternatives. A comparison of cow-calf operations with hybrid poplar and black walnut plantations suggests that a combination of pastureland and black walnut...
14 CFR 161.205 - Required analysis of proposed restriction and alternatives.
Code of Federal Regulations, 2010 CFR
2010-01-01
... of the anticipated or actual costs and benefits of the proposed noise or access restriction; (2) A... not involve aircraft restrictions, and a comparison of the costs and benefits of such alternative measures to costs and benefits of the proposed noise or access restriction. (b) In preparing the analyses...
Long-Term Follow-Up of an Alternative Medical Curriculum.
ERIC Educational Resources Information Center
Foster, Eugene A.
1994-01-01
A 20-year follow-up study of 37 students enrolled in a University of Virginia alternative medical education curriculum found the program was successful in improving students' morale during preclinical instruction, preparing them for clerkships, and increasing sensitivity to patients. It was not effective in inducing students to enter primary care…
Thinking Outside the Block: An Innovative Alternative to 4X4 Block Scheduling.
ERIC Educational Resources Information Center
Frank, Myra
2002-01-01
Introduces a 4x1 block scheduling method that was developed as an alternative to 4x4 block scheduling. Schedules Fridays for summer school, test preparation, and enrichment and elective courses. Includes suggestions on how to alleviate drawbacks of the 4x1 block schedule. (YDS)
Special Educators' Perceptions on Effective Preparation and Practice for Student Success
ERIC Educational Resources Information Center
Liese, Aerial Anne
2018-01-01
Alternative school settings are success prospects for students at risk of school failure. However, research on the daily experiences of the special educators in alternate school settings tasked with educating the at-risk population, is limited. The purpose of this phenomenological study was (a) to recognize the perceptions of special educators…
Local alternative energy futures: developing economies/building communities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Totten, M.; Glass, B.; Freedberg, M.
A separate abstract was prepared for each of the three parts of the conference. A sufficient range of information is presented to enable interested parties to explore the viable alternatives for community self-sufficiency. The parts are entitled: Financial Incentives and Funding Sources; Standards, Regulations, Mandates, Ordinances, Covenants; and Community/Economic Development. (MCW)
Integrating Complementary and Alternative Medicine into the Health Education Curriculum.
ERIC Educational Resources Information Center
Patterson, Sheila M.; Graf, Helen M.
2000-01-01
Reviews the popularity of complementary and alternative medicine (CAM) approaches in health education, suggesting a proposed CAM course for health education professional preparation and offering a course outline which can be used as a self- standing course or integrated into existing courses. It includes a proposed course description and goals,…
ERIC Educational Resources Information Center
Haberman, Martin
1992-01-01
To adequately prepare effective teachers for urban schools, traditional university-based programs of teacher education need to make serious structural and content changes. This article offers 16 assertions about specific changes that are needed and maintains that, in many alternative certification programs, most of the 16 assertions are…
ERIC Educational Resources Information Center
Sass, Tim R.
2011-01-01
Traditionally, states have required individuals complete a program of study in a university-based teacher preparation program in order to be licensed to teach. In recent years, however, various "alternative certification" programs have been developed and the number of teachers obtaining teaching certificates through routes other than…
Model Disciplinary Policies. Research Note. Volume 0902
ERIC Educational Resources Information Center
Blazer, Christie
2009-01-01
This Research Note is in response to a request from the Office of Alternative Education to review and report on "model disciplinary policies" as used in school districts around the nation. The primary source of information used to prepare this Research Note came from a professional group identified by Alternative Education. The Advancement…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
... performance standards nor does it provide the level of protection for which the project was authorized. A full... consideration of all alternatives, the best plan will be selected to achieve acceptable risk levels. FOR FURTHER... identified alternatives, especially aesthetics, communities, economics, biological and cultural resources...
ERIC Educational Resources Information Center
Rosenberg, Michael S.; Boyer, K. Lynn; Sindelar, Paul T.; Misra, Sunil K.
2007-01-01
This study describes special education alternative route (AR) teacher preparation programs. The authors developed a national database of programs and collected information on program sponsorship, length and intensity, features, and participant demographics. Most of the 235 programs in the database were in states that had significant shortages of…
ERIC Educational Resources Information Center
Pennsylvania Department of Education, 2005
2005-01-01
This document was prepared to serve as an aid in the planning, design, implementation, and ongoing evaluation of Alternative Education for Disruptive Youth Programs in Pennsylvania. School Codes and Public Laws are cited for guidance on mandatory issues. The suggestions and implementation strategies provided in this document are not requirements…
An Alternative Method for Teaching and Testing Reading Comprehension.
ERIC Educational Resources Information Center
Courchene, Robert
1995-01-01
The summary cloze technique offers an alternative to multiple choice. Summary cloze exercises are prepared by summarizing the content of the original text. The shortened text is transformed into a rational cloze exercise. The learner completes the summary text using the list of choices provided. This technique is a good measure of reading…
Preparation of Regular Specimens for Atom Probes
NASA Technical Reports Server (NTRS)
Kuhlman, Kim; Wishard, James
2003-01-01
A method of preparation of specimens of non-electropolishable materials for analysis by atom probes is being developed as a superior alternative to a prior method. In comparison with the prior method, the present method involves less processing time. Also, whereas the prior method yields irregularly shaped and sized specimens, the present developmental method offers the potential to prepare specimens of regular shape and size. The prior method is called the method of sharp shards because it involves crushing the material of interest and selecting microscopic sharp shards of the material for use as specimens. Each selected shard is oriented with its sharp tip facing away from the tip of a stainless-steel pin and is glued to the tip of the pin by use of silver epoxy. Then the shard is milled by use of a focused ion beam (FIB) to make the shard very thin (relative to its length) and to make its tip sharp enough for atom-probe analysis. The method of sharp shards is extremely time-consuming because the selection of shards must be performed with the help of a microscope, the shards must be positioned on the pins by use of micromanipulators, and the irregularity of size and shape necessitates many hours of FIB milling to sharpen each shard. In the present method, a flat slab of the material of interest (e.g., a polished sample of rock or a coated semiconductor wafer) is mounted in the sample holder of a dicing saw of the type conventionally used to cut individual integrated circuits out of the wafers on which they are fabricated in batches. A saw blade appropriate to the material of interest is selected. The depth of cut and the distance between successive parallel cuts is made such that what is left after the cuts is a series of thin, parallel ridges on a solid base. Then the workpiece is rotated 90 and the pattern of cuts is repeated, leaving behind a square array of square posts on the solid base. The posts can be made regular, long, and thin, as required for samples for atom-probe analysis. Because of their small volume and regularity, the amount of FIB-milling time can be much less than that of the method of sharp shards. Individual posts can be broken off for mounting in a manner similar to that of the method of sharp shards. Alternatively, the posts can be left intact on the base and the base can be cut to a small square (e.g., 3 by 3 mm) suitable for mounting in an atom probe of a type capable of accepting multiple-tip specimens. The advantage of multiple-tip specimens is the possibility of analyzing many tips without the time-consuming interchange of specimens.
46 CFR 164.009-15 - Test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... material, is less than 47 mm, the specimens prepared consist of layers of the sample. (3) If the sample is a composite material and has a height that is not 50 ±3mm, the layers of the specimen prepared are proportional in thickness to the layers of the sample. (4) The top and bottom faces of each specimen prepared...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
[Effect of a preparation from Chaetomium fungi on the growth of phytopathogenic fungi].
Tomilova, O G; Shternshis, M V
2006-01-01
We studied the fungicidal activity of a biological preparation from the fungi of the genus Chaetomium against soil phytopathogenic fungi Rhizoctonia solani and Fusarium oxysporum. The inhibitory effect of the preparation under study depended on its concentration, duration of storage, and growth characteristics of pure cultures of the phytopathogens. The highest (98.8%) inhibitory activity was observed on day 3 of the interaction with Rhizoctonia solani. After a 2-year storage, this preparation was capable of inhibiting the growth of the phytopathogens only at high doses. The preparation precluded the development of bare patch and increased the productivity of potato plants. The preparation may serve as an alternative to chemical fungicides for plant protection.
Satzke, Catherine; Dunne, Eileen M; Porter, Barbara D; Klugman, Keith P; Mulholland, E Kim
2015-11-01
The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high.
Satzke, Catherine; Dunne, Eileen M.; Porter, Barbara D.; Klugman, Keith P.; Mulholland, E. Kim
2015-01-01
Background The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Methods and Findings Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Conclusions Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high. PMID:26575033
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaiser, Brooke LD; Wunschel, David S.; Sydor, Michael A.
2015-08-07
Proteomic analysis of bacterial samples provides valuable information about cellular responses and functions under different environmental pressures. Proteomic analysis is dependent upon efficient extraction of proteins from bacterial samples without introducing bias toward extraction of particular protein classes. While no single method can recover 100% of the bacterial proteins, selected protocols can improve overall protein isolation, peptide recovery, or enrich for certain classes of proteins. The method presented here is technically simple and does not require specialized equipment such as a mechanical disrupter. Our data reveal that for particularly challenging samples, such as B. anthracis Sterne spores, trichloroacetic acid extractionmore » improved the number of proteins identified within a sample compared to bead beating (714 vs 660, respectively). Further, TCA extraction enriched for 103 known spore specific proteins whereas bead beating resulted in 49 unique proteins. Analysis of C. botulinum samples grown to 5 days, composed of vegetative biomass and spores, showed a similar trend with improved protein yields and identification using our method compared to bead beating. Interestingly, easily lysed samples, such as B. anthracis vegetative cells, were equally as effectively processed via TCA and bead beating, but TCA extraction remains the easiest and most cost effective option. As with all assays, supplemental methods such as implementation of an alternative preparation method may provide additional insight to the protein biology of the bacteria being studied.« less
Déglon, Julien; Versace, François; Lauer, Estelle; Widmer, Christèle; Mangin, Patrice; Thomas, Aurélien; Staub, Christian
2012-06-01
Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
Lytou, Anastasia E; Nychas, George-John E; Panagou, Efstathios Z
2018-02-21
Pomegranate juice is a product with enhanced functional properties that could be used as an alternative to traditional marination ingredients and effectively retard microbial growth along with providing an improved sensory result. In this study, two pomegranate based marinades were prepared for the marination of chicken breast fillets and the marinated samples were aerobically stored at 4 and 10°C for 9days. Raw, non-marinated chicken samples were used as control. Levels of total viable counts (TVC), Pseudomonas spp., Brochothrix thermosphacta, Enterobacteriaceae and lactic acid bacteria (LAB) were determined together with sensory assessment to evaluate the evolution of spoilage. The profile of organic acids and volatile compounds was also analyzed during storage. The shelf life of marinated samples was significantly extended compared to control samples at both storage temperatures (e.g., up to 5 and 6days for the pomegranate/lemon marinated samples stored at 4 and 10°C, respectively) as evaluated by both microbiological and sensory analyses. The profile of the organic acids and the volatilome of marinated and control samples were remarkably differentiated according to storage time, microbial load and sensory score. The findings of this study suggest that pomegranate juice could be used as a novel ingredient in marinades to improve the sensory attributes, while prolonging the shelf life of chicken meat. Copyright © 2017 Elsevier B.V. All rights reserved.
Levine, Keith E; Levine, Michael A; Weber, Frank X; Hu, Ye; Perlmutter, Jason; Grohse, Peter M
2005-01-01
The concentrations of mercury in forty, commercially available dietary supplements, were determined using a new, inexpensive analysis technique. The method involves thermal decomposition, amalgamation, and detection of mercury by atomic absorption spectrometry with an analysis time of approximately six minutes per sample. The primary cost savings from this approach is that labor-intensive sample digestion is not required prior to analysis, further automating the analytical procedure. As a result, manufacturers and regulatory agencies concerned with monitoring lot-to-lot product quality may find this approach an attractive alternative to the more classical acid-decomposition, cold vapor atomic absorption methodology. Dietary supplement samples analyzed included astragalus, calcium, chromium picolinate, echinacea, ephedra, fish oil, ginger, ginkgo biloba, ginseng, goldenseal, guggul, senna, St John's wort, and yohimbe products. Quality control samples analyzed with the dietary supplements indicated a high level of method accuracy and precision. Ten replicate preparations of a standard reference material (NIST 1573a, tomato leaves) were analyzed, and the average mercury recovery was 109% (2.0% RSD). The method quantitation limit was 0.3 ng, which corresponded to 1.5 ng/g sample. The highest found mercury concentration (123 ng/g) was measured in a concentrated salmon oil sample. When taken as directed by an adult, this product would result in an approximate mercury ingestion of 7 mug per week.
Herruzo, R; Vizcaino, M J; Yela, R
2018-04-01
Surgical use of 4% chlorhexidine soap (CHX-4) and 10% povidone iodine (PVP-I-10) does not meet the standards defined by EN 12791. To investigate the possibility of increasing the immediate and residual effects of these antiseptics. Over three consecutive weeks, n-propanol, standard CHX-4 and PVP-I-10 were tested in two experimental groups of volunteers. The new method for applying the antiseptic substances involved standard hand rub and rinse of CHX-4 or PVP-I-10, followed by application of an aqueous solution based on 5% chlorhexidine or PVP-I-10 with no further rinsing of the hands prior to donning gloves. Samples were taken to assess immediate and residual effects, analysing the logarithmic reduction of colony-forming units. At t=0 h, n-propanol was superior in bactericidal effect to standard CHX-4 (P<0.05), but the new chlorhexidine protocol was superior to both standard CHX-4 (P<0.01) and n-propanol (P<0.05); the same effect was observed at t=3 h (residual effect). At t=0 h, n-propanol was significantly superior to standard PVP-I-10, but the new PVP-I-10 protocol was superior, although not significantly, to n-propanol. There was no significant residual effect at t=3 h. The new protocol for chlorhexidine application permits surgical hand preparation with chlorhexidine, as a safe alternative to alcohol solutions, because it meets the standards defined by EN 12791. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finger, F.J.; Todd, Q.R.
An Environmental Investigation and Alternatives Assessment was conducted for the Crime Records Center at Fort Holabird in Baltimore, Maryland. Groundwater sampling, underground storage tank tightness testing, radon sampling, asbestos sampling, soil observations, and a review of previously collected data were used to develop remedial alternatives and recommendations. Removal and record keeping were recommended for asbestos. The recommendation for groundwater was no action.
A Quantitative Description of a Teacher Preparation Program. Educational Curriculum and Instruction.
ERIC Educational Resources Information Center
Denton, Jon J.; Morris, Geneva W.
A research program has been initiated at Texas A&M University College of Education to collect, analyze, and interpret data from a diagnostic prescriptive teacher preparation program. The project was undertaken to create a substantial data file containing multiple measures of learner attainment information that will provide alternatives for…
Training vs. Education in Forming Won Buddhist "Kyomus" in the USA
ERIC Educational Resources Information Center
Kim, Bokin
2006-01-01
An historically familiar tension in East Asian Buddhism between meditation and cultivation in broad learning has appeared in discussions and planning for preparing ministerial students in Won Buddhism. This paper reviews the history of preparation in this order, which was founded in 1916. While the alternatives of training based on practice and…
Perspectives and Practices of Graduates of an Urban Teacher Residency Program
ERIC Educational Resources Information Center
Tricarico, Katie M.
2012-01-01
Many traditional university-based and alternative route teacher preparation programs have been developed to prepare new teachers to work in urban, high minority, and high-poverty classrooms. There is little literature that documents the outcomes of these programs designed specifically for urban environments or the practices of teachers who…
ERIC Educational Resources Information Center
Aspen Institute, 2009
2009-01-01
Beyond Grey Pinstripes is a research survey and alternative ranking of business schools that spotlights innovative full-time MBA programs leading the way in integrating social and environmental stewardship into their curriculum and scholarly research. These schools are preparing today's students--tomorrow's leaders--for future market realities by…
ERIC Educational Resources Information Center
Vallesi, Antonino; Shallice, Tim
2007-01-01
In a variable foreperiod (FP) paradigm, reaction times (RTs) decrease as a function of FP on trial n (FP effect) but increase with FP on trial n = 1 (sequential effects). These phenomena have traditionally been ascribed to different strategic preparation processes. According to an alternative explanation, common conditioning laws underlie both…
ERIC Educational Resources Information Center
Lumby, Jacky; English, Fenwick
2009-01-01
This article challenges the largely Western, functionalist and unitary notion of the self which underlies contemporary international approaches to educational leadership preparation. It locates an alternative concept of the self as simultaneously singular and multiple in deep-rooted and persisting mythic, religious and metaphysical thinking. The…
Does Pre-Service Preparation Matter? Examining an Old Question in New Ways
ERIC Educational Resources Information Center
Ronfeldt, Matthew
2014-01-01
Background: Over the past decade, most of the quantitative studies on teacher preparation have focused on comparisons between alternative and traditional routes. There has been relatively little quantitative research on specific features of teacher education that might cause certain pathways into teaching to be more effective than others. The vast…
Preparing Leaders for Math and Science: Three Alternatives to Traditional Preparation
ERIC Educational Resources Information Center
Lochmiller, Chad R.; Huggins, Kristin S.; Acker-Hocevar, Michele A.
2012-01-01
Improving student achievement in math and science has become a priority in the United States. As instructional leaders, principals can influence instruction in these vital subjects by working with classroom teachers to improve their instruction. Surprisingly, the research about the principal's role in supporting instruction in these subjects is…
Integrated Model of Teacher Preparation: An Alternate Representation
ERIC Educational Resources Information Center
Gafoor K., Abdul
2011-01-01
The paper proposes an integrated model of pre-service preparation of teachers by incorporating the principles of critical and constructive approach to teacher education. The paper is an attempt to share the draft of the model with the national audience of teacher educators. The model proposed is integrated, among other things, in that in addition…
ERIC Educational Resources Information Center
Zozakiewicz, Cathy
2010-01-01
Teacher education is challenged with preparing teachers to work effectively with culturally diverse students. Gaps in the research literature demonstrate that more bridging is needed between teacher education coursework and student teaching experiences, particularly in terms of supervision approaches that consider multicultural issues. This study…
ERIC Educational Resources Information Center
Harris, Steven A.; Camp, William E.; Adkison, Judith
Low initial employment rates and high attrition among teachers are factors recognized as major contributors to the national teacher shortage. This research compared the effectiveness of three teacher preparation methods used in Texas: alternative certification programs (ACPs), Centers for Professional Development and Technology (CPDTs), and…
ERIC Educational Resources Information Center
Brady, Michael P.; Heiser, Lawrence A.; McCormick, Jazarae K.; Forgan, James
2016-01-01
High-stakes standardized student assessments are increasingly used in value-added evaluation models to connect teacher performance to P-12 student learning. These assessments are also being used to evaluate teacher preparation programs, despite validity and reliability threats. A more rational model linking student performance to candidates who…
Young Adult Books: Helping to Prepare Teachers for Augmentative Alternative Communication
ERIC Educational Resources Information Center
Donne, Vicki
2016-01-01
Many educators have reported limited education in their training or preparation programs on assistive technology and communication devices. The present study reported on action research conducted in this area using book study groups. Participants included graduate students enrolled in a face-to-face course required within their special education…
Selecting Top-of-the-Class Teachers for an Alternative Principal Preparation Program
ERIC Educational Resources Information Center
Mallory, Barbara J.; Zwadyk, Barbara; Johnson, Tina; Davis, James V.
2017-01-01
In an attempt to improve training and development of principals, the General Assembly in North Carolina established a competitive grant program to transform the way principals are certified. This qualitative study aimed to inform principal preparation practices by examining the initial, critical steps of recruitment, screening, and selection of…
Potential Alternatives Report for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes
NASA Technical Reports Server (NTRS)
Lewis, pattie
2011-01-01
Identifying and selecting alternative materials and technologies that have the potential to reduce the identified HazMats and hazardous air pollutants (HAPs), while incorporating sound corrosion prevention and control technologies, is a complicated task due to the fast pace at which new technologies emerge and rules change. The alternatives are identified through literature searches, electronic database and Internet searches, surveys, and/or personal and professional contacts. Available test data was then compiled on the proposed alternatives to determine if the materials meet the test objectives or if further)laboratory or field-testing will be required. After reviewing technical information documented in the PAR, government representatives, technical representatives from the affected facilities, and other stakeholders involved in the process will select the list of viable alternative coatings for consideration and testing under the project's Joint Test Protocol entitled Joint Test Protocol for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes and Field Test Plan entitled Field Evaluations Test Plan for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes, both prepared by ITB. Test results will be reported in a Joint Test Report upon completion oftesting. The selection rationale and conclusions are documented in this PAR. A cost benefit analysis will be prepared to quantify the estimated capital and process costs of coating alternatives and cost savings relative to the current coating processes, however, some initial cost data has been included in this PAR. For this coatings project, isocyanates, as found in aliphatic isocyanate polyurethanes, were identified as the target HazMat to be eliminated. Table 1-1 lists the target HazMats, the related process and application, current specifications, and affected programs.
Chmura, Helen E; Meddle, Simone L; Wingfield, John C; Hahn, Thomas P
2017-08-15
To time reproduction optimally, birds have evolved diverse mechanisms by which they respond to environmental changes that help them anticipate and prepare for the breeding season. While residents initiate reproductive preparation and breed in the same geographic location, migrant birds simultaneously prepare for breeding and migration far from their breeding grounds. As a result, it is hypothesized that migrant and resident birds use environmental cues differently to prepare to breed and that there is adaptive specialization in mechanisms regulating reproductive preparation. Specifically, residents are expected to rely more on non-photic cues (e.g. food, temperature, social cues) than migrants. We tested this general prediction using a social cue manipulation. First, we compared the effects of subspecies-appropriate recorded male song on reproductive development in migrants and residents on a naturally increasing photoperiod. Second, we tested the sensitivity of migrant-specific life history events (fattening and pre-alternate molt) to song treatment. After 82 days, residents had higher luteinizing hormone and greater ovarian development than migrants, but song treatment had no effect on these metrics in either subspecies. Song advanced pre-alternate molt but had no effect on fattening in migrants. While our study does not support specialization in social cue use in migrants and residents, it is consistent with findings in the literature of specialization in photoperiodic response. It also demonstrates for the first time that social cues can influence molt in a migrant species. Additional findings from a pilot study looking at responses to a live male suggest it is important to test other kinds of social cues. © 2017. Published by The Company of Biologists Ltd.
La 2-xSr xCuO 4-δ superconducting samples prepared by the wet-chemical method
NASA Astrophysics Data System (ADS)
Loose, A.; Gonzalez, J. L.; Lopez, A.; Borges, H. A.; Baggio-Saitovitch, E.
2009-10-01
In this work, we report on the physical properties of good-quality polycrystalline superconducting samples of La 2-xSr xCu 1-yZn yO 4-δ ( y=0, 0.02) prepared by a wet-chemical method, focusing on the temperature dependence of the critical current. Using the wet-chemical method, we were able to produce samples with improved homogeneity compared to the solid-state method. A complete set of samples with several carrier concentrations, ranging from the underdoped (strontium concentration x≈0.05) to the highly overdoped ( x≈0.25) region, were prepared and investigated. The X-ray diffraction analysis, zero-field cooling magnetization and electrical resistivity measurements were reported on earlier. The structural parameters of the prepared samples seem to be slightly modified by the preparation method and their critical temperatures were lower than reported in the literature. The temperature dependence of the critical current was explained by a theoretical model which took the granular structure of the samples into account.
Automated SEM and TEM sample preparation applied to copper/low k materials
NASA Astrophysics Data System (ADS)
Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.
2001-01-01
We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.
Struwe, Weston B; Agravat, Sanjay; Aoki-Kinoshita, Kiyoko F; Campbell, Matthew P; Costello, Catherine E; Dell, Anne; Ten Feizi; Haslam, Stuart M; Karlsson, Niclas G; Khoo, Kay-Hooi; Kolarich, Daniel; Liu, Yan; McBride, Ryan; Novotny, Milos V; Packer, Nicolle H; Paulson, James C; Rapp, Erdmann; Ranzinger, Rene; Rudd, Pauline M; Smith, David F; Tiemeyer, Michael; Wells, Lance; York, William S; Zaia, Joseph; Kettner, Carsten
2016-09-01
The minimum information required for a glycomics experiment (MIRAGE) project was established in 2011 to provide guidelines to aid in data reporting from all types of experiments in glycomics research including mass spectrometry (MS), liquid chromatography, glycan arrays, data handling and sample preparation. MIRAGE is a concerted effort of the wider glycomics community that considers the adaptation of reporting guidelines as an important step towards critical evaluation and dissemination of datasets as well as broadening of experimental techniques worldwide. The MIRAGE Commission published reporting guidelines for MS data and here we outline guidelines for sample preparation. The sample preparation guidelines include all aspects of sample generation, purification and modification from biological and/or synthetic carbohydrate material. The application of MIRAGE sample preparation guidelines will lead to improved recording of experimental protocols and reporting of understandable and reproducible glycomics datasets. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
[Recent advances in sample preparation methods of plant hormones].
Wu, Qian; Wang, Lus; Wu, Dapeng; Duan, Chunfeng; Guan, Yafeng
2014-04-01
Plant hormones are a group of naturally occurring trace substances which play a crucial role in controlling the plant development, growth and environment response. With the development of the chromatography and mass spectroscopy technique, chromatographic analytical method has become a widely used way for plant hormone analysis. Among the steps of chromatographic analysis, sample preparation is undoubtedly the most vital one. Thus, a highly selective and efficient sample preparation method is critical for accurate identification and quantification of phytohormones. For the three major kinds of plant hormones including acidic plant hormones & basic plant hormones, brassinosteroids and plant polypeptides, the sample preparation methods are reviewed in sequence especially the recently developed methods. The review includes novel methods, devices, extractive materials and derivative reagents for sample preparation of phytohormones analysis. Especially, some related works of our group are included. At last, the future developments in this field are also prospected.
40 CFR 761.326 - Conducting the comparison study.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Conducting the comparison study. 761...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the comparison study samples using the alternative method. For an alternative extraction method or alternative...
40 CFR 761.326 - Conducting the comparison study.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Conducting the comparison study. 761...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the comparison study samples using the alternative method. For an alternative extraction method or alternative...
Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; de Vries, Tjerk; Portugal-Cohen, Meital; Antonio, Diana C; Cascio, Claudia; Calzolai, Luigi; Gilliland, Douglas; de Mello, Andrew
2016-04-01
We demonstrate the use of inverse supercritical carbon dioxide (scCO2) extraction as a novel method of sample preparation for the analysis of complex nanoparticle-containing samples, in our case a model sunscreen agent with titanium dioxide nanoparticles. The sample was prepared for analysis in a simplified process using a lab scale supercritical fluid extraction system. The residual material was easily dispersed in an aqueous solution and analyzed by Asymmetrical Flow Field-Flow Fractionation (AF4) hyphenated with UV- and Multi-Angle Light Scattering detection. The obtained results allowed an unambiguous determination of the presence of nanoparticles within the sample, with almost no background from the matrix itself, and showed that the size distribution of the nanoparticles is essentially maintained. These results are especially relevant in view of recently introduced regulatory requirements concerning the labeling of nanoparticle-containing products. The novel sample preparation method is potentially applicable to commercial sunscreens or other emulsion-based cosmetic products and has important ecological advantages over currently used sample preparation techniques involving organic solvents. Copyright © 2016 Elsevier B.V. All rights reserved.
Sample preparation techniques for the determination of trace residues and contaminants in foods.
Ridgway, Kathy; Lalljie, Sam P D; Smith, Roger M
2007-06-15
The determination of trace residues and contaminants in complex matrices, such as food, often requires extensive sample extraction and preparation prior to instrumental analysis. Sample preparation is often the bottleneck in analysis and there is a need to minimise the number of steps to reduce both time and sources of error. There is also a move towards more environmentally friendly techniques, which use less solvent and smaller sample sizes. Smaller sample size becomes important when dealing with real life problems, such as consumer complaints and alleged chemical contamination. Optimal sample preparation can reduce analysis time, sources of error, enhance sensitivity and enable unequivocal identification, confirmation and quantification. This review considers all aspects of sample preparation, covering general extraction techniques, such as Soxhlet and pressurised liquid extraction, microextraction techniques such as liquid phase microextraction (LPME) and more selective techniques, such as solid phase extraction (SPE), solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE). The applicability of each technique in food analysis, particularly for the determination of trace organic contaminants in foods is discussed.
Qiu, Junlang; Wang, Fuxin; Zhang, Tianlang; Chen, Le; Liu, Yuan; Zhu, Fang; Ouyang, Gangfeng
2018-01-02
Decreasing the tedious sample preparation duration is one of the most important concerns for the environmental analytical chemistry especially for in vivo experiments. However, due to the slow mass diffusion paths for most of the conventional methods, ultrafast in vivo sampling remains challenging. Herein, for the first time, we report an ultrafast in vivo solid-phase microextraction (SPME) device based on electrosorption enhancement and a novel custom-made CNT@PPY@pNE fiber for in vivo sampling of ionized acidic pharmaceuticals in fish. This sampling device exhibited an excellent robustness, reproducibility, matrix effect-resistant capacity, and quantitative ability. Importantly, the extraction kinetics of the targeted ionized pharmaceuticals were significantly accelerated using the device, which significantly improved the sensitivity of the SPME in vivo sampling method (limits of detection ranged from 0.12 ng·g -1 to 0.25 ng·g -1 ) and shorten the sampling time (only 1 min). The proposed approach was successfully applied to monitor the concentrations of ionized pharmaceuticals in living fish, which demonstrated that the device and fiber were suitable for ultrafast in vivo sampling and continuous monitoring. In addition, the bioconcentration factor (BCF) values of the pharmaceuticals were derived in tilapia (Oreochromis mossambicus) for the first time, based on the data of ultrafast in vivo sampling. Therefore, we developed and validated an effective and ultrafast SPME sampling device for in vivo sampling of ionized analytes in living organisms and this state-of-the-art method provides an alternative technique for future in vivo studies.
Sample Preparation Techniques for Grain Boundary Characterization of Annealed TRISO-Coated Particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunzik-Gougar, M. L.; van Rooyen, I. J.; Hill, C. M.
Crystallographic information about chemical vapor deposition layers of silicon carbide (SiC) is essential to understanding layer performance, especially when the layers are in non planar geometries, such as spherical. We performed electron Back Scatter Diffraction (EBSD) analysis of spherical SiC layers using a different approach to sample focus ion beam milling technique to avoid the negative impacts of traditional sample polishing and to address the need of very small samples of irradiated materials for analysis. Mechanical and chemical grinding and polishing of sample surfaces can introduce lattice strains and result in unequal removal of SiC and surrounding layers of differentmore » material due to the hardness differences of these materials. The nature of layer interfaces is thought to play a key role in performance of the SiC; therefore, analysis of representative samples at these interfacial areas is crucial. In work reported here, a focused ion beam (FIB) was employed in a novel manner to prepare a more representative sample for EBSD analysis from TRISO layers free of effects introduced by mechanical and chemical preparation methods. In addition, the difficulty of handling neutron irradiated microscopic samples such as those analyzed in this work has been simplified with pre tilted mounting stages. Our study showed that although the average grain size of samples may be similar, the grain boundary characteristics may differ significantly. It was also found that low angle grain boundaries, comprises 25% in the FIB-prepared sample vs only 1-2% in the polished sample measured in the same particle. From this study it was determined that results of FIB prepared sample will provide more repeatable results, as the role of sample preparation is eliminated.« less
Sample Preparation Techniques for Grain Boundary Characterization of Annealed TRISO-Coated Particles
Dunzik-Gougar, M. L.; van Rooyen, I. J.; Hill, C. M.; ...
2016-08-25
Crystallographic information about chemical vapor deposition layers of silicon carbide (SiC) is essential to understanding layer performance, especially when the layers are in non planar geometries, such as spherical. We performed electron Back Scatter Diffraction (EBSD) analysis of spherical SiC layers using a different approach to sample focus ion beam milling technique to avoid the negative impacts of traditional sample polishing and to address the need of very small samples of irradiated materials for analysis. Mechanical and chemical grinding and polishing of sample surfaces can introduce lattice strains and result in unequal removal of SiC and surrounding layers of differentmore » material due to the hardness differences of these materials. The nature of layer interfaces is thought to play a key role in performance of the SiC; therefore, analysis of representative samples at these interfacial areas is crucial. In work reported here, a focused ion beam (FIB) was employed in a novel manner to prepare a more representative sample for EBSD analysis from TRISO layers free of effects introduced by mechanical and chemical preparation methods. In addition, the difficulty of handling neutron irradiated microscopic samples such as those analyzed in this work has been simplified with pre tilted mounting stages. Our study showed that although the average grain size of samples may be similar, the grain boundary characteristics may differ significantly. It was also found that low angle grain boundaries, comprises 25% in the FIB-prepared sample vs only 1-2% in the polished sample measured in the same particle. From this study it was determined that results of FIB prepared sample will provide more repeatable results, as the role of sample preparation is eliminated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. D. Miller; J. Gan; J. Madden
2012-05-01
Transmission electron microscopy (TEM), scanning electron microscopy (SEM), and focused ion beam (FIB) milling were performed on an irradiated U-10Mo monolithic fuel to understand its irradiation microstructure. This is the first reported TEM work of irradiated fuel sample prepared using a FIB. Advantages and disadvantages of using the FIB to create TEM samples from this irradiated fuel will be presented along with some results from the work. Sample preparation techniques used to create SEM and FIB samples from the brittle irradiated monolithic sample will also be discussed.
Optimizing Illumina next-generation sequencing library preparation for extremely AT-biased genomes.
Oyola, Samuel O; Otto, Thomas D; Gu, Yong; Maslen, Gareth; Manske, Magnus; Campino, Susana; Turner, Daniel J; Macinnis, Bronwyn; Kwiatkowski, Dominic P; Swerdlow, Harold P; Quail, Michael A
2012-01-03
Massively parallel sequencing technology is revolutionizing approaches to genomic and genetic research. Since its advent, the scale and efficiency of Next-Generation Sequencing (NGS) has rapidly improved. In spite of this success, sequencing genomes or genomic regions with extremely biased base composition is still a great challenge to the currently available NGS platforms. The genomes of some important pathogenic organisms like Plasmodium falciparum (high AT content) and Mycobacterium tuberculosis (high GC content) display extremes of base composition. The standard library preparation procedures that employ PCR amplification have been shown to cause uneven read coverage particularly across AT and GC rich regions, leading to problems in genome assembly and variation analyses. Alternative library-preparation approaches that omit PCR amplification require large quantities of starting material and hence are not suitable for small amounts of DNA/RNA such as those from clinical isolates. We have developed and optimized library-preparation procedures suitable for low quantity starting material and tolerant to extremely high AT content sequences. We have used our optimized conditions in parallel with standard methods to prepare Illumina sequencing libraries from a non-clinical and a clinical isolate (containing ~53% host contamination). By analyzing and comparing the quality of sequence data generated, we show that our optimized conditions that involve a PCR additive (TMAC), produces amplified libraries with improved coverage of extremely AT-rich regions and reduced bias toward GC neutral templates. We have developed a robust and optimized Next-Generation Sequencing library amplification method suitable for extremely AT-rich genomes. The new amplification conditions significantly reduce bias and retain the complexity of either extremes of base composition. This development will greatly benefit sequencing clinical samples that often require amplification due to low mass of DNA starting material.
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the... PCB remediation waste at the cleanup site, or must be the same kind of material as that waste. For...
Shirado, Akemi; Morita, Tatsuya; Akazawa, Terukazu; Miyashita, Mitsunori; Sato, Kazuki; Tsuneto, Satoru; Shima, Yasuo
2013-05-01
Both maintaining hope and preparing for the patient's death are important for families of terminally ill cancer patients. The primary aim of this study was to clarify the level of the family's achievement of maintaining hope and preparing for death and the professional's behavior related to their evaluations. A cross-sectional, anonymous, nationwide survey was conducted involving 663 bereaved families of cancer patients who had been admitted to 100 palliative care units throughout Japan. A total of 454 family members returned the questionnaire (effective response rate, 68%). Overall, 73% of families reported that they could both maintain hope and prepare for the patient's death. The independent determinants of the family's agreement in reference to the professional's behavior are pacing the explanation with the family's preparation; coordinating patient and family discussions about priorities while the patient was in better condition; willingness to discuss alternative medicine; maximizing efforts to maintain the patient's physical strength (e.g., meals, rehabilitation); discussing specific, achievable goals; and not saying "I can no longer do anything for the patient." About 20% of family members reported that they could neither "maintain hope nor prepare for death." A recommended care strategy for medical professionals could include 1) discussing achievable goals and preparing for the future and pacing explanation with the family's preparation, 2) willingness to discuss alternative medicine, 3) maximizing efforts to maintain the patient's physical strength, and 4) avoid saying they could do nothing further for the patient. Copyright © 2013 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
Modular microfluidic system for biological sample preparation
Rose, Klint A.; Mariella, Jr., Raymond P.; Bailey, Christopher G.; Ness, Kevin Dean
2015-09-29
A reconfigurable modular microfluidic system for preparation of a biological sample including a series of reconfigurable modules for automated sample preparation adapted to selectively include a) a microfluidic acoustic focusing filter module, b) a dielectrophoresis bacteria filter module, c) a dielectrophoresis virus filter module, d) an isotachophoresis nucleic acid filter module, e) a lyses module, and f) an isotachophoresis-based nucleic acid filter.
Schüler, Susann; Wenz, Ingrid; Wiederanders, B; Slickers, P; Ehricht, R
2006-06-12
Recent developments in DNA microarray technology led to a variety of open and closed devices and systems including high and low density microarrays for high-throughput screening applications as well as microarrays of lower density for specific diagnostic purposes. Beside predefined microarrays for specific applications manufacturers offer the production of custom-designed microarrays adapted to customers' wishes. Array based assays demand complex procedures including several steps for sample preparation (RNA extraction, amplification and sample labelling), hybridization and detection, thus leading to a high variability between several approaches and resulting in the necessity of extensive standardization and normalization procedures. In the present work a custom designed human proteinase DNA microarray of lower density in ArrayTube format was established. This highly economic open platform only requires standard laboratory equipment and allows the study of the molecular regulation of cell behaviour by proteinases. We established a procedure for sample preparation and hybridization and verified the array based gene expression profile by quantitative real-time PCR (QRT-PCR). Moreover, we compared the results with the well established Affymetrix microarray. By application of standard labelling procedures with e.g. Klenow fragment exo-, single primer amplification (SPA) or In Vitro Transcription (IVT) we noticed a loss of signal conservation for some genes. To overcome this problem we developed a protocol in accordance with the SPA protocol, in which we included target specific primers designed individually for each spotted oligomer. Here we present a complete array based assay in which only the specific transcripts of interest are amplified in parallel and in a linear manner. The array represents a proof of principle which can be adapted to other species as well. As the designed protocol for amplifying mRNA starts from as little as 100 ng total RNA, it presents an alternative method for detecting even low expressed genes by microarray experiments in a highly reproducible and sensitive manner. Preservation of signal integrity is demonstrated out by QRT-PCR measurements. The little amounts of total RNA necessary for the analyses make this method applicable for investigations with limited material as in clinical samples from, for example, organ or tumour biopsies. Those are arguments in favour of the high potential of our assay compared to established procedures for amplification within the field of diagnostic expression profiling. Nevertheless, the screening character of microarray data must be mentioned, and independent methods should verify the results.
Mallik, Abul K; Noguchi, Hiroki; Rahman, Mohammed Mizanur; Takafuji, Makoto; Ihara, Hirotaka
2018-06-22
The synthesis of a new alternating copolymer-grafted silica phase is described for the separation of shape-constrained isomers of polycyclic aromatic hydrocarbons (PAHs) and tocopherols in reversed-phase high-performance liquid chromatography (RP-HPLC). Telomerization of the monomers (octadecyl acrylate and N-methylmaleimide) was carried out with a silane coupling agent; 3-mercaptopropyltrimethoxysilane (MPS), and the telomer (T) was grafted onto porous silica surface to prepare the alternating copolymer-grafted silica phase (Sil-alt-T). The new hybrid material was characterized by elemental analyses, diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy, and solid-state 13 C and 29 Si cross-polarization magic-angle spinning (CP/MAS) NMR spectroscopy. The results of 13 C CP/MAS NMR demonstrated that the alkyl chains of the grafted polymers in Sil-alt-T remained disordered, amorphous, and mobile represented by gauche conformational form. Separation abilities and molecular-shape selectivities of the prepared organic phase were evaluated by the separation of PAHs isomers and Standard Reference Material 869b, Column Selectivity Test Mixture for Liquid Chromatography, respectively and compared with commercially available octadecylsilylated silica (ODS) and C 30 columns as well as previously reported alternating copolymer-based column. The effectiveness of this phase is also demonstrated by the separation of tocopherol isomers. Oriented functional groups along the polymer main chains and cavity formations are investigated to be the driving force for better separation with multiple-interactions with the solutes. One of the advantages of the Sil-alt-T phase to that of the previously reported phase is the synthesis of the telomer first and then immobilized onto silica surface. In this case, the telomer was characterized easily with simple spectroscopic techniques and the molecular mass and polydispersity index of the telomer were determined by size exclusion chromatography (SEC) before grafting onto silica surface. Moreover, both of the monomers were commercially available. Therefore, the technique of preparation was very facile and better separation was achieved with the Sil-alt-T phase compared to the ODS, C 30 and other previously reported alternating copolymer-based columns. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, Haiming; Lin, Yaojun; Seidman, David N.
The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less
Wen, Haiming; Lin, Yaojun; Seidman, David N.; ...
2015-09-09
The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less
Critical evaluation of sample pretreatment techniques.
Hyötyläinen, Tuulia
2009-06-01
Sample preparation before chromatographic separation is the most time-consuming and error-prone part of the analytical procedure. Therefore, selecting and optimizing an appropriate sample preparation scheme is a key factor in the final success of the analysis, and the judicious choice of an appropriate procedure greatly influences the reliability and accuracy of a given analysis. The main objective of this review is to critically evaluate the applicability, disadvantages, and advantages of various sample preparation techniques. Particular emphasis is placed on extraction techniques suitable for both liquid and solid samples.
Preparation of protein samples for mass spectrometry and N-terminal sequencing.
Glenn, Gary
2014-01-01
The preparation of protein samples for mass spectrometry and N-terminal sequencing is a key step in successfully identifying proteins. Mass spectrometry is a very sensitive technique, and as such, samples must be prepared carefully since they can be subject to contamination of the sample (e.g., due to incomplete subcellular fractionation or purification of a multiprotein complex), overwhelming of the sample by highly abundant proteins, and contamination from skin or hair (keratin can be a very common hit). One goal of sample preparation for mass spec is to reduce the complexity of the sample - in the example presented here, mitochondria are purified, solubilized, and fractionated by sucrose density gradient sedimentation prior to preparative 1D SDS-PAGE. It is important to verify the purity and integrity of the sample so that you can have confidence in the hits obtained. More protein is needed for N-terminal sequencing and ideally it should be purified to a single band when run on an SDS-polyacrylamide gel. The example presented here involves stably expressing a tagged protein in HEK293 cells and then isolating the protein by affinity purification and SDS-PAGE. © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Taer, E.; Taslim, R.; Deraman, M.
2016-02-01
Preparation of activated carbon monolith (ACM) from rubber wood was investigated. Two kind of preparation method were carried out by pre-carbonized of rubber wood saw dust and rubber wood material as it is naturally. The samples were prepared with pelletizing method and small cutting of rubber wood in cross sectional method. Both of samples were characterized by physical and electrochemical technique. The physical properties such as morphology and porosity were investigated. The electrochemical properties of both samples such as equivalent series resistances (ESR) and specific capacitances were also compared. In conclusion, this study showed that both of different preparation method would propose a simple method of ACM electrode preparation technique for supercapacitor applications.
Wei, Binnian; Feng, June; Rehmani, Imran J; Miller, Sharyn; McGuffey, James E; Blount, Benjamin C; Wang, Lanqing
2014-09-25
Most sample preparation methods characteristically involve intensive and repetitive labor, which is inefficient when preparing large numbers of samples from population-scale studies. This study presents a robotic system designed to meet the sampling requirements for large population-scale studies. Using this robotic system, we developed and validated a method to simultaneously measure urinary anatabine, anabasine, nicotine and seven major nicotine metabolites: 4-Hydroxy-4-(3-pyridyl)butanoic acid, cotinine-N-oxide, nicotine-N-oxide, trans-3'-hydroxycotinine, norcotinine, cotinine and nornicotine. We analyzed robotically prepared samples using high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry in positive electrospray ionization mode using scheduled multiple reaction monitoring (sMRM) with a total runtime of 8.5 min. The optimized procedure was able to deliver linear analyte responses over a broad range of concentrations. Responses of urine-based calibrators delivered coefficients of determination (R(2)) of >0.995. Sample preparation recovery was generally higher than 80%. The robotic system was able to prepare four 96-well plate (384 urine samples) per day, and the overall method afforded an accuracy range of 92-115%, and an imprecision of <15.0% on average. The validation results demonstrate that the method is accurate, precise, sensitive, robust, and most significantly labor-saving for sample preparation, making it efficient and practical for routine measurements in large population-scale studies such as the National Health and Nutrition Examination Survey (NHANES) and the Population Assessment of Tobacco and Health (PATH) study. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leino, P.; Kosunen, P.; Rauhamaeki, J.
1997-05-01
The aim of the project was to study how various tax models for power plant fuels affect the fuel consumption and emissions of particles, sulphur dioxide (SO{sup 2}), nitrogen oxide (NOx) and carbon dioxide (CO{sup 2}). First, the development of Finnish energy taxation is discussed, followed by a survey of the energy production structure for 1994. For this purpose, it was necessary to prepare a large boiler database, which covers about 95% of the fuel consumption of Finnish energy production. The boiler database was used to calculate the emissions of particles, SO{sup 2}, NOx and CO{sup 2} in 1994. Themore » year 2010 selected under review is the year by which the Ministry of Trade and Industry has prepared their primary energy consumption estimates. Four different alternatives were studied as future tax models. In the first alternative taxation would be as it in years 1995--1996 and in the second alternative taxation would be as 1 January 1997. In the third alternative the Finnish application of EU taxes would be in force in full, i.e., the tax on heavy fuel oil would be 10 US dollars a barrel. In the fourth alternative there would be no taxes on fuels.« less
NASA Astrophysics Data System (ADS)
Ferguson, P. P.; Martine, M. L.; George, A. E.; Dahn, J. R.
Samples of Sn 30TM 30C 40 and of Sn 30Co 15TM 15C 40, with TM = 3d transition metals, were prepared by vertical-axis attritor milling. The structure and performance of these samples were studied by X-ray diffraction (XRD) and by electrochemical testing. The XRD patterns of Sn 30TM 30C 40 show an amorphous-like diffraction pattern only for the sample with TM = Co. The other prepared samples show broadened Bragg peaks of their main starting material, along with an amorphous-like background, even after 32 h of milling. Samples with TM = Co and TM = Ni show stable differential capacity versus potential plots and stable cycling for at least 100 cycles with reversible capacities of 425 and 250 mAh g -1, respectively. All samples prepared with 15 at.% Co show good capacity retention for at least 100 cycles ranging from 270 mAh g -1 for samples with TM = Ni to 500 mAh g -1 for samples with TM = Ti. The differential capacity versus potential plots for all the prepared Sn 30Co 15TM 15C 40 samples show similar structure to that of Sn 30Co 30C 40 except when TM = Cu. This shows the possibility of preparing tin-based negative electrode materials using a combination of cobalt and TM, especially if one looks to reduce the cobalt content.
Non-Contact Conductivity Measurement for Automated Sample Processing Systems
NASA Technical Reports Server (NTRS)
Beegle, Luther W.; Kirby, James P.
2012-01-01
A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... Energy Carolinas, LLC, to construct up to three (3) power generating wind turbines within the Pamlico... turbines in NC's coastal waters, entitled Coastal Wind, Energy for North Carolina's Future, dated June 2009... reasonable number of alternatives, including the no action alternative and constructing the wind turbines and...
ERIC Educational Resources Information Center
Gelfer, Jeffrey I.; Krasch, Delilah J.; O'Hara, Kathleen S.
2015-01-01
Teacher shortages are a pervasive global issue that is expected to continue, especially in low-performing, high-needs schools [O'Connor, E. A., Malow, M. S., & Bisland, B. M. (2011). Mentorship and instruction received during training: Views of alternatively certified teachers. "Educational Review," 63(2), 219-232]. In an effort to…
Effectiveness of an Alternative Certification Program for the Preparation of Elementary Teachers
ERIC Educational Resources Information Center
Follo, Eric J.; Rivard, James J.
2009-01-01
This study focuses on the effectiveness of the alternative elementary teacher certification program at Oakland University in Rochester, Michigan. The program was developed in response to the projected teacher shortage, the need for teachers in subjects such as mathematics and science, the need for teachers in urban schools, and the need for…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
....C. 1131-36) and other laws and policies, will frame the decision-making for the CRMP/EIS. The CRMP...-action and a preferred alternative. The potential environmental effects of each alternative will be... decisions related to this project are invited to participate in the scoping process and, if eligible, may...
Analyzing the Efficacy of the Testing Effect Using Kahoot™ on Student Performance
ERIC Educational Resources Information Center
Iwamoto, Darren H.; Hargis, Jace; Taitano, Erik Jon; Vuong, Ky
2017-01-01
Lower than expected high-stakes examination scores were being observed in a first-year general psychology class. This research sought an alternate approach that would assist students in preparing for high-stakes examinations. The purpose of this study was to measure the effectiveness of an alternate teaching approach based on the testing effect to…
ERIC Educational Resources Information Center
Roach, Virginia; Cohen, Benjamin A.
The debate over how to prepare a new generation of teachers has reached a fever pitch in education and policy communities. This policy brief takes the viewpoint that quality alternative certification programs (ACPs) offer ways to develop a broader pool of prospective teachers while helping states address concerns about teacher development,…
ERIC Educational Resources Information Center
Gaither, Linda
2013-01-01
Sixty percent of America's teachers choose traditional baccalaureate programs while the remaining choose one of several alternative pathways. While certification/training is certainly important to preparing effective teachers, other research indicates that teacher efficacy serves as the foundation of teacher behaviors and classroom practice. The…
ERIC Educational Resources Information Center
Cochran, Elizabeth
A teacher who teaches General Educational Development preparation to at-risk teenagers in a nonprofit alternative education program called FutureWorks conducted a study to identify those elements of FutureWorks that keep students coming to the program. The study included the following data collection activities: a consensus-building activity to…