Developmental neurotoxicity testing (DNT) is perceived by many stakeholders to be an area in critical need of alternative methods to current animal testing protocols and gUidelines. An immediate goal is to develop test methods that are capable of screening large numbers of chemic...
Misra, Ashish; Green, Michael R
2017-01-01
Alternative splicing is a regulated process that leads to inclusion or exclusion of particular exons in a pre-mRNA transcript, resulting in multiple protein isoforms being encoded by a single gene. With more than 90 % of human genes known to undergo alternative splicing, it represents a major source for biological diversity inside cells. Although in vitro splicing assays have revealed insights into the mechanisms regulating individual alternative splicing events, our global understanding of alternative splicing regulation is still evolving. In recent years, genome-wide RNA interference (RNAi) screening has transformed biological research by enabling genome-scale loss-of-function screens in cultured cells and model organisms. In addition to resulting in the identification of new cellular pathways and potential drug targets, these screens have also uncovered many previously unknown mechanisms regulating alternative splicing. Here, we describe a method for the identification of alternative splicing regulators using genome-wide RNAi screening, as well as assays for further validation of the identified candidates. With modifications, this method can also be adapted to study the splicing regulation of pre-mRNAs that contain two or more splice isoforms.
Li, Wei; Zhang, Min; Wang, Mingyu; Han, Zhantao; Liu, Jiankai; Chen, Zhezhou; Liu, Bo; Yan, Yan; Liu, Zhu
2018-06-01
Brownfield sites pollution and remediation is an urgent environmental issue worldwide. The screening and assessment of remedial alternatives is especially complex owing to its multiple criteria that involves technique, economy, and policy. To help the decision-makers selecting the remedial alternatives efficiently, the criteria framework conducted by the U.S. EPA is improved and a comprehensive method that integrates multiple criteria decision analysis (MCDA) with numerical simulation is conducted in this paper. The criteria framework is modified and classified into three categories: qualitative, semi-quantitative, and quantitative criteria, MCDA method, AHP-PROMETHEE (analytical hierarchy process-preference ranking organization method for enrichment evaluation) is used to determine the priority ranking of the remedial alternatives and the solute transport simulation is conducted to assess the remedial efficiency. A case study was present to demonstrate the screening method in a brownfield site in Cangzhou, northern China. The results show that the systematic method provides a reliable way to quantify the priority of the remedial alternatives.
Stickie removal using neutral enzymatic repulping pressure screening
Marguerite Sykes; John Klungness; Roland Gleisner; Said Abubakr
1998-01-01
Removal of stickie contaminants is currently a major focus of paper recycling research. Medium consistency alkaline repulping followed by pressure screening has proven to be effective for stickie removal. There is, however, an alternate method that is equally effective and more environmentally benign. This study compares the effectiveness of this alternative method,...
Aiding alternatives assessment with an uncertainty-tolerant hazard scoring method.
Faludi, Jeremy; Hoang, Tina; Gorman, Patrick; Mulvihill, Martin
2016-11-01
This research developed a single-score system to simplify and clarify decision-making in chemical alternatives assessment, accounting for uncertainty. Today, assessing alternatives to hazardous constituent chemicals is a difficult task-rather than comparing alternatives by a single definitive score, many independent toxicological variables must be considered at once, and data gaps are rampant. Thus, most hazard assessments are only comprehensible to toxicologists, but business leaders and politicians need simple scores to make decisions. In addition, they must balance hazard against other considerations, such as product functionality, and they must be aware of the high degrees of uncertainty in chemical hazard data. This research proposes a transparent, reproducible method to translate eighteen hazard endpoints into a simple numeric score with quantified uncertainty, alongside a similar product functionality score, to aid decisions between alternative products. The scoring method uses Clean Production Action's GreenScreen as a guide, but with a different method of score aggregation. It provides finer differentiation between scores than GreenScreen's four-point scale, and it displays uncertainty quantitatively in the final score. Displaying uncertainty also illustrates which alternatives are early in product development versus well-defined commercial products. This paper tested the proposed assessment method through a case study in the building industry, assessing alternatives to spray polyurethane foam insulation containing methylene diphenyl diisocyanate (MDI). The new hazard scoring method successfully identified trade-offs between different alternatives, showing finer resolution than GreenScreen Benchmarking. Sensitivity analysis showed that different weighting schemes in hazard scores had almost no effect on alternatives ranking, compared to uncertainty from data gaps. Copyright © 2016 Elsevier Ltd. All rights reserved.
A Case Study on Reducing Children's Screen Time: The Project of Screen Free Week
ERIC Educational Resources Information Center
Kara, Hatice Gözde Ertürk
2018-01-01
The current study aims to direct children to alternative activities within a week period by applying the project of screen free week to voluntary families. The ultimate aim of the study is to reduce children's screen time. The instrumental case study method; one of the qualitative research methods, was employed. Five children attending the…
Circling motion and screen edges as an alternative input method for on-screen target manipulation.
Ka, Hyun W; Simpson, Richard C
2017-04-01
To investigate a new alternative interaction method, called circling interface, for manipulating on-screen objects. To specify a target, the user makes a circling motion around the target. To specify a desired pointing command with the circling interface, each edge of the screen is used. The user selects a command before circling the target. To evaluate the circling interface, we conducted an experiment with 16 participants, comparing the performance on pointing tasks with different combinations of selection method (circling interface, physical mouse and dwelling interface) and input device (normal computer mouse, head pointer and joystick mouse emulator). A circling interface is compatible with many types of pointing devices, not requiring physical activation of mouse buttons, and is more efficient than dwell-clicking. Across all common pointing operations, the circling interface had a tendency to produce faster performance with a head-mounted mouse emulator than with a joystick mouse. The performance accuracy of the circling interface outperformed the dwelling interface. It was demonstrated that the circling interface has the potential as another alternative pointing method for selecting and manipulating objects in a graphical user interface. Implications for Rehabilitation A circling interface will improve clinical practice by providing an alternative pointing method that does not require physically activating mouse buttons and is more efficient than dwell-clicking. The Circling interface can also work with AAC devices.
Alternative Approaches for Screening Contaminated Sediments and Soils for PCDD/PCDF
Generating analytical data for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) using the traditional high resolution mass spectrometry (HRMS) analysis method, EPA Method 1613B, is time-consuming and expensive. Consequently, alternative methods to ...
A Triangulation Method for Identifying Hydrostratigraphic Locations of Well Screens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiteside, T. S.
2015-01-31
A method to identify the hydrostratigraphic location of well screens was developed using triangulation with known locations. This method was applied to all of the monitor wells being used to develop the new GSA groundwater model. Results from this method are closely aligned with those from an alternate method which uses a mesh surface.
Anttila, Ahti; Pokhrel, Arun; Kotaniemi-Talonen, Laura; Hakama, Matti; Malila, Nea; Nieminen, Pekka
2011-03-01
The purpose was to evaluate alternative cytological screening methods in population-based screening for cervical cancer up to cancer incidence and mortality outcome. Automation-assisted screening was compared to conventional cytological screening in a randomized design. The study was based on follow-up of 503,391 women invited in the Finnish cervical cancer screening program during 1999-2003. The endpoints were incident cervical cancer, severe intraepithelial neoplasia and deaths from cervical cancer. One third of the women had been randomly allocated to automation-assisted screening and two thirds to conventional cytology. Information on cervical cancer and severe neoplasia were obtained through 1999-2007 from a linkage between screening and cancer registry files. There were altogether 3.2 million woman-years at risk, and the average follow-up time was 6.3 years. There was no difference in the risk of cervical cancer between the automation-assisted and conventional screening methods; the relative risk (RR) of cervical cancer between the study and control arm was 1.00 (95% confidence interval [CI] = 0.76-1.29) among all invited and 1.08 (95% CI = 0.76-1.51) among women who were test negative at entry. Comparing women who were test negative with nonscreened, RR of cervical cancer incidence was 0.26, 95% CI = 0.19-0.36 and of mortality 0.24 (0.13-0.43). Both methods were valid for screening. Because cervical cancer is rare in our country, we cannot rule out small differences between methods. Evidence on alternative methods for cervical cancer screening is increasing and it is thus feasible to evaluate new methods in large-scale population-based screening programs up to cancer outcome. Copyright © 2010 UICC.
Rapid screening of guar gum using portable Raman spectral identification methods.
Srivastava, Hirsch K; Wolfgang, Steven; Rodriguez, Jason D
2016-01-25
Guar gum is a well-known inactive ingredient (excipient) used in a variety of oral pharmaceutical dosage forms as a thickener and stabilizer of suspensions and as a binder of powders. It is also widely used as a food ingredient in which case alternatives with similar properties, including chemically similar gums, are readily available. Recent supply shortages and price fluctuations have caused guar gum to come under increasing scrutiny for possible adulteration by substitution of cheaper alternatives. One way that the U.S. FDA is attempting to screen pharmaceutical ingredients at risk for adulteration or substitution is through field-deployable spectroscopic screening. Here we report a comprehensive approach to evaluate two field-deployable Raman methods--spectral correlation and principal component analysis--to differentiate guar gum from other gums. We report a comparison of the sensitivity of the spectroscopic screening methods with current compendial identification tests. The ability of the spectroscopic methods to perform unambiguous identification of guar gum compared to other gums makes them an enhanced surveillance alternative to the current compendial identification tests, which are largely subjective in nature. Our findings indicate that Raman spectral identification methods perform better than compendial identification methods and are able to distinguish guar gum from other gums with 100% accuracy for samples tested by spectral correlation and principal component analysis. Published by Elsevier B.V.
The U.S. Environmental Protection Agency is developing and evaluating methods to screen and prioritize large numbers of chemicals for developmental toxicity. Towards this goal, we are exploring methods to detect developmental neurotoxicants in very young larval zebrafish. We have...
Lowry, Kathryn P.; Lee, Janie M.; Kong, Chung Y.; McMahon, Pamela M.; Gilmore, Michael E.; Cott Chubiz, Jessica E.; Pisano, Etta D.; Gatsonis, Constantine; Ryan, Paula D.; Ozanne, Elissa M.; Gazelle, G. Scott
2011-01-01
Background While breast cancer screening with mammography and MRI is recommended for BRCA mutation carriers, there is no current consensus on the optimal screening regimen. Methods We used a computer simulation model to compare six annual screening strategies [film mammography (FM), digital mammography (DM), FM and magnetic resonance imaging (MRI) or DM and MRI contemporaneously, and alternating FM/MRI or DM/MRI at six-month intervals] beginning at ages 25, 30, 35, and 40, and two strategies of annual MRI with delayed alternating DM/FM to clinical surveillance alone. Strategies were evaluated without and with mammography-induced breast cancer risk, using two models of excess relative risk. Input parameters were obtained from the medical literature, publicly available databases, and calibration. Results Without radiation risk effects, alternating DM/MRI starting at age 25 provided the highest life expectancy (BRCA1: 72.52 years, BRCA2: 77.63 years). When radiation risk was included, a small proportion of diagnosed cancers were attributable to radiation exposure (BRCA1: <2%, BRCA2: <4%). With radiation risk, alternating DM/MRI at age 25 or annual MRI at age 25/delayed alternating DM at age 30 were most effective, depending on the radiation risk model used. Alternating DM/MRI starting at age 25 also had the highest number of false-positive screens/person (BRCA1: 4.5, BRCA2: 8.1). Conclusions Annual MRI at 25/delayed alternating DM at age 30 is likely the most effective screening strategy in BRCA mutation carriers. Screening benefits, associated risks and personal acceptance of false-positive results, should be considered in choosing the optimal screening strategy for individual women. PMID:21935911
Hwang, Jessica P.; Roundtree, Aimee K.; Suarez-Almazor, Maria E.
2017-01-01
Objectives We explored attitudes about prevention, screening and treatment of hepatitis B virus (HBV) infection in Chinese, Korean and Vietnamese communities. Methods We use qualitative methods in 12 focus groups (n=113) of adults who self-reported their ethnicity to be Chinese, Korean, or Vietnamese. We use grounded theory (i.e., consensus-building between co-coders about recurring, emerging themes) for analysis. Results Diet, nutrition, fatigue and stress were misidentified as HBV causes. Improving hygiene, diet, exercise, and holistic methods were misidentified as viable HBV prevention methods. Common screening problems included not affording test and not understanding test results. Participants shared reasons for using complementary and alternative medicine—when Western medicine fails or becomes unaffordable. Participants sought information from medical providers and fellow community members, but also from the internet. Conclusions Many of the attitudes and opinions that emerged may deter participation in HBV screening, prevention and treatment, insofar as community members may factor them into healthcare decision-making, choose alternative but ineffective methods of prevention and treatment, and undervalue the benefits of screening. More patient education in both traditional and new media is necessary for clarifying transmission, screening and treatment misunderstandings. PMID:22302653
Navy Fuel Composition and Screening Tool (FCAST) v.2.5
2014-07-18
a major impediment to certification of these fuels as Fit-For- Purpose (FFP) for the U.S. Navy. A method whereby a candidate fuel could be rapidly...the U.S. Navy. A method whereby a candidate fuel could be rapidly screened for many FFP properties, using a minimal volume (< 1 mL), would overcome...mobility fuels with new alternative fuels, regardless of their source or processing methods . The Fuel Composition and Screening Tool (FCAST) was
Preventive Screening of Women Who Use Complementary and Alternative Medicine Providers
Tyree, Patrick T.; Lafferty, William E.
2009-01-01
Abstract Background Many women use complementary and alternative medicine (CAM). Although CAM use has been associated with reductions in conventionally recommended pediatric preventive care (e.g., vaccination), little is known about associations between CAM use and receipt of recommended preventive screening in women. Methods Using Washington State insurance data from 2000 to 2003, the authors generated clustered logistic regression models, examining associations between provider-based CAM use and receipt of screening tests for Chlamydia trachomatis, breast cancer, and cervical cancer: (1) contrasting women who used CAM providers only (alternative use) and women who used both conventional and CAM providers (complementary use) with women who used conventional care only and (2) testing associations between screening and use of four specific CAM provider types—naturopathic physicians, chiropractors, massage therapists, and acupuncturists. Results Both alternative and complementary use was associated with reduced Chlamydia screening. Cancer screening increased with complementary use but decreased with alternative use of CAM. Use of naturopathy was associated with decreased mammography, whereas all four CAM therapies were positively associated with Papanicolaou testing. Conclusions When used in conjunction with conventional care, use of provider-based CAM may signal high interest in various types of health-promoting behavior, including cancer screening. Negative associations between CAM and Chlamydia screening and between naturopathy and mammography require additional study. Interventions with CAM providers and their patients, aimed at improving rates of conventionally recommended screening, might encourage greater focus on preventive care, an important task when CAM providers serve as women's only contact with the healthcare system. PMID:19630554
Alternative toxicity assessment methods to characterize the hazards of chemical substances have been proposed to reduce animal testing and screen thousands of chemicals in an efficient manner. Resources to accomplish these goals include utilizing large in vitro chemical screening...
Hwang, Jessica P; Roundtree, Aimee K; Suarez-Almazor, Maria E
2012-10-01
We explored attitudes about prevention, screening and treatment of hepatitis B virus (HBV) infection in Chinese, Korean and Vietnamese communities. We use qualitative methods in 12 focus groups (n = 113) of adults who self-reported their ethnicity to be Chinese, Korean, or Vietnamese. We use grounded theory (i.e., consensus-building between co-coders about recurring, emerging themes) for analysis. Diet, nutrition, fatigue and stress were misidentified as HBV causes. Improving hygiene, diet, exercise, and holistic methods were misidentified as viable HBV prevention methods. Common screening problems included not affording test and not understanding test results. Participants shared reasons for using complementary and alternative medicine--when Western medicine fails or becomes unaffordable. Participants sought information from medical providers and fellow community members, but also from the internet. Many of the attitudes and opinions that emerged may deter participation in HBV screening, prevention and treatment, insofar as community members may factor them into healthcare decision-making, choose alternative but ineffective methods of prevention and treatment, and undervalue the benefits of screening. More patient education in both traditional and new media is necessary for clarifying transmission, screening and treatment misunderstandings.
Tyagi, Rakesh Kumar
2003-04-01
Although a number of screening methods being used for identifying potential endocrine disruptors have generated a wealth of information, a search for alternative combination of methods is still needed to overcome experimental artefacts. There are no generally accepted or validated screening methods for monitoring and studying impact of environmental endocrine disruptors. Also, no single assay can accurately predict all the deleterious effects of endocrine disruptors. For this reason various environmental protection agencies, mainly European and US, have urged that a battery of tests in current use need to be designed to assess their adequacy in detecting the effects of endocrine disruptors. Some details about endocrine disruptors and screening programs can be found at http://www.epa.gov/scipoly/oscpendo/whatis.htm. Several studies in recent years have used fusion proteins between steroid receptors (estrogen, androgen, progesterone, etc.) and green fluorescent protein (GFP) that can serve as an alternative potent screening method to study intracellular dynamics of receptors in living cells. An approach employing nucleocytoplasmic trafficking of steroid receptors as a parameter in response to potential xenobiotic chemicals in living cells may prove to be promising in terms of being direct, fast, reliable, simple and inexpensive. Copyright 2003 Elsevier Science Ltd.
Cost-effectiveness analysis of mammography and clinical breast examination strategies
Ahern, Charlotte Hsieh; Shen, Yu
2009-01-01
Purpose Breast cancer screening by mammography and clinical breast exam are commonly used for early tumor detection. Previous cost-effectiveness studies considered mammography alone or did not account for all relevant costs. In this study, we assessed the cost-effectiveness of screening schedules recommended by three major cancer organizations and compared them with alternative strategies. We considered costs of screening examinations, subsequent work-up, biopsy, and treatment interventions after diagnosis. Methods We used a microsimulation model to generate women’s life histories, and assessed screening and treatment impacts on survival. Using statistical models, we accounted for age-specific incidence, preclinical disease duration, and age-specific sensitivity and specificity for each screening modality. The outcomes of interest were quality-adjusted life years (QALYs) saved and total costs with a 3% annual discount rate. Incremental cost-effectiveness ratios were used to compare strategies. Sensitivity analyses were performed by varying some of the assumptions. Results Compared to guidelines from the National Cancer Institute and the U.S. Preventive Services Task Force, alternative strategies were more efficient. Mammography and clinical breast exam in alternating years from ages 40 to 79 was a cost-effective alternative compared to the guidelines, costing $35,500 per QALY saved compared with no screening. The American Cancer Society guideline was the most effective and the most expensive, costing over $680,000 for an added QALY compared to the above alternative. Conclusion Screening strategies with lower costs and benefits comparable to those currently recommended should be considered for implementation in practice and for future guidelines. PMID:19258473
USDA-ARS?s Scientific Manuscript database
The comprehensive identification of genes underlying phenotypic variation of complex traits remains a major challenge. Most genome-wide screens lack sufficient resolving power as they typically depend on linkage. An alternate method is to screen for allele-specific expression (ASE), a simple yet pow...
IRAS: High-Throughput Identification of Novel Alternative Splicing Regulators.
Zheng, S
2016-01-01
Alternative splicing is a fundamental regulatory process of gene expression. Defects in alternative splicing can lead to various diseases, and modification of disease-causing splicing events presents great therapeutic promise. Splicing outcome is commonly affected by extracellular stimuli and signaling cascades that converge on RNA-binding splicing regulators. These trans-acting factors recognize cis-elements in pre-mRNA transcripts to affect spliceosome assembly and splice site choices. Identification of these splicing regulators and/or upstream modulators has been difficult and traditionally done by piecemeal. High-throughput screening strategies to find multiple regulators of exon splicing have great potential to accelerate the discovery process, but typically confront low sensitivity and low specificity of screening assays. Here we describe a unique screening strategy, IRAS (identifying regulators of alternative splicing), using a pair of dual-output minigene reporters to allow for sensitive detection of exon splicing changes. Each dual-output reporter produces green fluorescent protein (GFP) and red fluorescent protein (RFP) fluorescent signals to assay the two spliced isoforms exclusively. The two complementary minigene reporters alter GFP/RFP output ratios in the opposite direction in response to splicing change. Applying IRAS in cell-based high-throughput screens allows sensitive and specific identification of splicing regulators and modulators for any alternative exons of interest. In comparison to previous high-throughput screening methods, IRAS substantially enhances the specificity of the screening assay. This strategy significantly eliminates false positives without sacrificing sensitive identification of true regulators of splicing. © 2016 Elsevier Inc. All rights reserved.
Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis
2017-11-01
Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.
[New guidelines in regard to cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Acosta-Altamirano, Gustavo; Moreno-Eutimio, Mario Adán; Vargas-Aguilar, Víctor Manuel
2014-01-01
Cancer screening programs have been successful in reducing the incidence and mortality due to cervical cancer. For more than a decade, the human papillomavirus test has been recommended as part of these programs, however, Pap tests is not currently recommended for women 65 years of age who participated adequately in screening programs, continuing with these screening programs is not needed. Screening programs will be different in special populations at greatest risk where tests are frequently needed or use of alternative methods.
The U.S. Environmental Protection Agency is evaluating methods to screen and prioritize large numbers of chemicals for developmental toxicity. As such, we are exploring a behavioral testing paradigm, which can assess the effect of sublethal and subteratogenic concentrations of de...
A choice-based screening method for compulsive drug users in rats.
Lenoir, Magalie; Augier, Eric; Vouillac, Caroline; Ahmed, Serge H
2013-07-01
We describe a protocol for screening compulsive drug users among cocaine self-administering rats, the most frequently used animal model in addiction research. Rats are first trained on several alternating days to self-administer either cocaine (i.v.) or saccharin-sweetened water (by mouth)--a potent, albeit nonessential, nondrug reward. Then rats are allowed to choose between the two rewards over several days until the preference stabilizes. Most rats choose to stop using cocaine and pursue the alternative reward. Only a minority of Wistar strain rats (generally 15%) persist in taking the drug, regardless of the severity of past cocaine use and even when made hungry and offered the possibility to relieve their physiological need. Persistence of cocaine use in the face of a high-stakes choice is a core defining feature of compulsion. This choice-based screening method for compulsive drug users is easy to implement, has several important applications, and compares well with other methods in the field. 2013 by John Wiley & Sons, Inc.
A Disposable Microfluidic Device with a Screen Printed Electrode for Mimicking Phase II Metabolism
Vasiliadou, Rafaela; Nasr Esfahani, Mohammad Mehdi; Brown, Nathan J.; Welham, Kevin J.
2016-01-01
Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler and a cheaper alternative to mimic the human metabolism. This paper describes the development of a disposable microfluidic device with a screen-printed electrode (SPE) for monitoring phase II GSH reactions. The proposed chip has the potential to be used as a primary screening tool, thus complementing the current in vitro methods. PMID:27598162
Due to their toxicity and persistence in the environment, brominated flame retardants (BFRs) are being phased out of commercial use, leading to the increased use of alternative chemicals such as the organophosphorus flame retardants (OPFRs). Due to the structural similarity of th...
One use of alternative methods is to target animal use at only those chemicals and tests that are absolutely necessary. We discuss prioritization of testing based on high-throughput screening assays (HTS), QSAR modeling, high-throughput toxicokinetics (HTTK), and exposure modelin...
We are evaluating methods to screen/prioritize large numbers of chemicals using 6 day old zebrafish (Danio rerio) as an alternative model for detecting neurotoxic effects. Our behavioral testing paradigm simultaneously tests individual larval zebrafish under sequential light and...
The U.S. Environmental Protection Agency is evaluating methods to screen and prioritize large numbers of chemicals using 6 day old zebrafish (Danio rerio) as an alternative test model for detecting neurotoxic chemicals. We use a behavioral testing paradigm that simultaneously tes...
Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick
2015-01-01
Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020
Implementing a method of screening one-well hydraulic barrier design alternatives.
Rubin, Hillel; Shoemaker, Christine A; Köngeter, Jürgen
2009-01-01
This article provides details of applying the method developed by the authors (Rubin et al. 2008b) for screening one-well hydraulic barrier design alternatives. The present article with its supporting information (manual and electronic spreadsheets with a case history example) provides the reader complete details and examples of solving the set of nonlinear equations developed by Rubin et al. (2008b). It allows proper use of the analytical solutions and also depicting the various charts given by Rubin et al. (2008b). The final outputs of the calculations are the required position and the discharge of the pumping well. If the contaminant source is nonaqueous phase liquid (NAPL) entrapped within the aquifer, then the method provides an estimate of the aquifer remediation progress (which is a by-product) due to operating the hydraulic barrier.
Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes
Titoiu, Ana Maria; Marty, Jean-Louis
2018-01-01
This review provides a brief overview of the fabrication and properties of screen-printed electrodes and details the different opportunities to apply them for the detection of antibiotics, detection of bacteria and antibiotic susceptibility. Among the alternative approaches to costly chromatographic or ELISA methods for antibiotics detection and to lengthy culture methods for bacteria detection, electrochemical biosensors based on screen-printed electrodes present some distinctive advantages. Chemical and (bio)sensors for the detection of antibiotics and assays coupling detection with screen-printed electrodes with immunomagnetic separation are described. With regards to detection of bacteria, the emphasis is placed on applications targeting viable bacterial cells. While the electrochemical sensors and biosensors face many challenges before replacing standard analysis methods, the potential of screen-printed electrodes is increasingly exploited and more applications are anticipated to advance towards commercial analytical tools. PMID:29562637
Lin, Sung-Yao; Sun, Xing-Han; Hsiao, Yu-Hsuan; Chang, Shao-En; Li, Guan-Syun; Hu, Nien-Jen
2016-01-01
Membrane proteins play key roles in many fundamental functions in cells including ATP synthesis, ion and molecule transporter, cell signalling and enzymatic reactions, accounting for ~30% genes of whole genomes. However, the hydrophobic nature of membrane proteins frequently hampers the progress of structure determination. Detergent screening is the critical step in obtaining stable detergent-solubilized membrane proteins and well-diffracting protein crystals. Fluorescence Detection Size Exclusion Chromatography (FSEC) has been developed to monitor the extraction efficiency and monodispersity of membrane proteins in detergent micelles. By tracing the FSEC profiles of GFP-fused membrane proteins, this method significantly enhances the throughput of detergent screening. However, current methods to acquire FSEC profiles require either an in-line fluorescence detector with the SEC equipment or an off-line spectrofluorometer microplate reader. Here, we introduce an alternative method detecting the absorption of GFP (FA-SEC) at 485 nm, thus making this methodology possible on conventional SEC equipment through the in-line absorbance spectrometer. The results demonstrate that absorption is in great correlation with fluorescence of GFP. The comparably weaker absorption signal can be improved by using a longer path-length flow cell. The FA-SEC profiles were congruent with the ones plotted by FSEC, suggesting FA-SEC could be a comparable and economical setup for detergent screening of membrane proteins.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DADO MA
2008-07-31
This study focuses on the remediation methods and technologies applicable for use at 200-PO-I Groundwater Operable Unit (OU) at the Hanford Site. The 200-PO-I Groundwater au requires groundwater remediation because of the existence of contaminants of potential concern (COPC). A screening was conducted on alternative technologies and methods of remediation to determine which show the most potential for remediation of groundwater contaminants. The possible technologies were screened to determine which would be suggested for further study and which were not applicable for groundwater remediation. COPCs determined by the Hanford Site groundwater monitoring were grouped into categories based on properties linkingmore » them by remediation methods applicable to each COPC group. The screening considered the following criteria. (1) Determine if the suggested method or technology can be used for the specific contaminants found in groundwater and if the technology can be applied at the 200-PO-I Groundwater au, based on physical characteristics such as geology and depth to groundwater. (2) Evaluate screened technologies based on testing and development stages, effectiveness, implementability, cost, and time. This report documents the results of an intern research project conducted by Mathew Dado for Central Plateau Remediation in the Soil and Groundwater Remediation Project. The study was conducted under the technical supervision of Gloria Cummins and management supervision of Theresa Bergman and Becky Austin.« less
Selby-Harrington, M; Sorenson, J R; Quade, D; Stearns, S C; Tesh, A S; Donat, P L
1995-01-01
OBJECTIVES. A randomized controlled trial was conducted to test the effectiveness and cost effectiveness of three outreach interventions to promote well-child screening for children on Medicaid. METHODS. In rural North Carolina, a random sample of 2053 families with children due or overdue for screening was stratified according to the presence of a home phone. Families were randomly assigned to receive a mailed pamphlet and letter, a phone call, or a home visit outreach intervention, or the usual (control) method of informing at Medicaid intake. RESULTS. All interventions produced more screenings than the control method, but increases were significant only for families with phones. Among families with phones, a home visit was the most effective intervention but a phone call was the most cost-effective. However, absolute rates of effectiveness were low, and incremental costs per effect were high. CONCLUSIONS. Pamphlets, phone calls, and home visits by nurses were minimally effective for increasing well-child screenings. Alternate outreach methods are needed, especially for families without phones. PMID:7573627
Shinozaki, Takashi; Watanabe, Ryuichi; Kawatsu, Kentaro; Sakurada, Kiyonari; Takahi, Shinya; Ueno, Ken-ichi; Matsushima, Ryoji; Suzuki, Toshiyuki
2013-01-01
We investigated the applicability of enzyme-linked immunosorbent assay (PSP-ELISA) using a monoclonal antibody against paralytic shellfish toxins (PST) for screening oysters collected at several coastal areas in Kumamoto prefecture, Japan. Oysters collected between 2007 and 2010 were analyzed by PSP-ELISA. As an alternative calibrant, a naturally contaminated oyster extract was used to quantify toxins in the oyster samples. The toxicity of the calibrant oyster extract determined by the official testing method, mouse bioassay (MBA), was 4 MU/g. Oyster samples collected over 3 years showed a similar toxin profile to the alternative standard, resulting in good agreement between the PSP-ELISA and the MBA. The PSP-ELISA method was better than the MBA in terms of sensitivity, indicating that it may be useful for earlier warning of contamination of oysters by PST in the distinct coastal areas. To use the PSP-ELISA as a screening method prior to MBA, we finally set a screening level at 2 MU/g PSP-ELISA for oyster monitoring in Kumamoto prefecture. We confirmed that there were on samples exceeding the quarantine level (4 MU/g) in MBA among samples quantified as below the screening level by the PSP-ELISA. It was concluded that the use of PSP-ELISA could reduce the numbers of animals needed for MBA testing.
ABSTRACT BODY: Thousands of chemicals lack adequate testing for adverse effects on nervous system development, stimulating research into alternative methods to screen chemicals for potential developmental neurotoxicity. Microelectrode arrays (MEA) collect action potential spiking...
The Trojan Horse Method in nuclear astrophysics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spitaleri, C., E-mail: spitaleri@lns.infn.it; Mukhamedzhanov, A. M.; Blokhintsev, L. D.
2011-12-15
The study of energy production and nucleosynthesis in stars requires an increasingly precise knowledge of the nuclear reaction rates at the energies of interest. To overcome the experimental difficulties arising from the small cross sections at those energies and from the presence of the electron screening, the Trojan Horse Method has been introduced. The method provides a valid alternative path to measure unscreened low-energy cross sections of reactions between charged particles, and to retrieve information on the electron screening potential when ultra-low energy direct measurements are available.
Fragment Screening and HIV Therapeutics
Bauman, Joseph D.; Patel, Disha; Arnold, Eddy
2013-01-01
Fragment screening has proven to be a powerful alternative to traditional methods for drug discovery. Biophysical methods, such as X-ray crystallography, NMR spectroscopy, and surface plasmon resonance, are used to screen a diverse library of small molecule compounds. Although compounds identified via this approach have relatively weak affinity, they provide a good platform for lead development and are highly efficient binders with respect to their size. Fragment screening has been utilized for a wide-range of targets, including HIV-1 proteins. Here, we review the fragment screening studies targeting HIV-1 proteins using X-ray crystallography or surface plasmon resonance. These studies have successfully detected binding of novel fragments to either previously established or new sites on HIV-1 protease and reverse transcriptase. In addition, fragment screening against HIV-1 reverse transcriptase has been used as a tool to better understand the complex nature of ligand binding to a flexible target. PMID:21972022
Liu, Rui-Sang; Jin, Guang-Huai; Xiao, Deng-Rong; Li, Hong-Mei; Bai, Feng-Wu; Tang, Ya-Jie
2015-01-01
Aroma results from the interplay of volatile organic compounds (VOCs) and the attributes of microbial-producing aromas are significantly affected by fermentation conditions. Among the VOCs, only a few of them contribute to aroma. Thus, screening and identification of the key VOCs is critical for microbial-producing aroma. The traditional method is based on gas chromatography-olfactometry (GC-O), which is time-consuming and laborious. Considering the Tuber melanosporum fermentation system as an example, a new method to screen and identify the key VOCs by combining the aroma evaluation method with principle component analysis (PCA) was developed in this work. First, an aroma sensory evaluation method was developed to screen 34 potential favorite aroma samples from 504 fermentation samples. Second, PCA was employed to screen nine common key VOCs from these 34 samples. Third, seven key VOCs were identified by the traditional method. Finally, all of the seven key VOCs identified by the traditional method were also identified, along with four others, by the new strategy. These results indicate the reliability of the new method and demonstrate it to be a viable alternative to the traditional method. PMID:26655663
High throughput screening of active pharmaceutical ingredients by UPLC.
Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun
2008-07-01
Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.
Quantitative screening of yeast surface-displayed polypeptide libraries by magnetic bead capture.
Yeung, Yik A; Wittrup, K Dane
2002-01-01
Magnetic bead capture is demonstrated here to be a feasible alternative for quantitative screening of favorable mutants from a cell-displayed polypeptide library. Flow cytometric sorting with fluorescent probes has been employed previously for high throughput screening for either novel binders or improved mutants. However, many laboratories do not have ready access to this technology as a result of the limited availability and high cost of cytometers, restricting the use of cell-displayed libraries. Using streptavidin-coated magnetic beads and biotinylated ligands, an alternative approach to cell-based library screening for improved mutants was developed. Magnetic bead capture probability of labeled cells is shown to be closely correlated with the surface ligand density. A single-pass enrichment ratio of 9400 +/- 1800-fold, at the expense of 85 +/- 6% binder losses, is achieved from screening a library that contains one antibody-displaying cell (binder) in 1.1 x 10(5) nondisplaying cells. Additionally, kinetic screening for an initial high affinity to low affinity (7.7-fold lower) mutant ratio of 1:95,000, the magnetic bead capture method attains a single-pass enrichment ratio of 600 +/- 200-fold with a 75 +/- 24% probability of loss for the higher affinity mutant. The observed high loss probabilities can be straightforwardly compensated for by library oversampling, given the inherently parallel nature of the screen. Overall, these results demonstrate that magnetic beads are capable of quantitatively screening for novel binders and improved mutants. The described methods are directly analogous to procedures in common use for phage display and should lower the barriers to entry for use of cell surface display libraries.
The U.S. EPA is developing alternative screening methods to identify putative developmental neurotoxicants and prioritize chemicals for additional testing. One method developmentally exposes zebrafish embryos and assesses nervous system structure at 2 days post-fertilization (dpf...
Alternative Solvents/Technologies for Paint Stripping: Phase 1.
1994-03-01
processes . Three phases of study are defined: Phase I, identify alternate solvents/strippers and screen them; Phase II, field test solvent/ strippers...Section Title Page 1 Metal Refinishing Process - Immersion Method ............... 8 2 Phase Summary Chart ........................ 12 3 The...of the following: (a) nontoxic chemical formulations, (b) new process development, and (c) new coating reformulations. This program consists of three
Comparison of the PSC-17 and Alternative Mental Health Screens in an At-Risk Primary Care Sample
ERIC Educational Resources Information Center
Gardner, William; Lucas, Amanda; Kolko, David J.; Campo, John V.
2007-01-01
Objective: To validate the 17-item version of the Pediatric Symptom Checklist (PSC-17) as a screen for common pediatric mental disorders in primary care. Method: Patients were 269 children and adolescents (8-15 years old) whose parents completed the PSC-17 in primary care waiting rooms. Children were later assessed using the Schedule for Affective…
NEW METHODS TO SCREEN FOR DEVELOPMENTAL NEUROTOXICITY.
The development of alternative methods for toxicity testing is driven by the need for scientifically valid data (i.e. predictive of a toxic effect) that can be obtained in a rapid and cost-efficient manner. These predictions will enable decisions to be made as to whether further ...
Validation of Screening Assays for Developmental Toxicity: An Exposure-Based Approach
There continue to be widespread efforts to develop assay methods for developmental toxicity that are shorter than the traditional Segment 2 study and use fewer or no animals. As with any alternative test method, novel developmental toxicity assays must be validated by evaluating ...
Alternative Host Models for Testing Anti-Protozoal or Antifungal Compounds and Fungal Infection.
Torrecilhas, Ana Claudia; Xander, Patricia; Ferreira, Karen Spadari; Batista, Wagner Luiz
2018-01-01
The neglected tropical diseases (NTDs) are caused by several parasites, fungi, bacteria and viruses and affect more than one billion people in the world. The control and prevention against NTDs need implementation of alternative methods for testing new compounds against these diseases. For the implementation of alternative methods, it is necessary to apply the principles of replacement, reduction and refinement (the 3Rs) for the use of laboratory animals. Accordingly, the present review addressed a variety of alternative models to study the infections caused by protozoa and fungi. Overall, vertebrate and invertebrate models of fungal infection have been used to elucidate host-pathogen interactions. However, until now the insect model has not been used in protozoal studies as an alternative method, but there is interest in the scientific community to try new tools to screen alternative drugs to control and prevent protozoal infections. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
DOT National Transportation Integrated Search
2011-01-01
The objective of network screening should ideally be to not only identify sites for safety : investigation but also to prioritize those sites efficiently. Using roadway, intersection, and : collision data from California, this study compared the perf...
Berrue, Fabrice; Withers, Sydnor T; Haltli, Brad; Withers, Jo; Kerr, Russell G
2011-03-21
Marine invertebrates have proven to be a rich source of secondary metabolites. The growing recognition that marine microorganisms associated with invertebrate hosts are involved in the biosynthesis of secondary metabolites offers new alternatives for the discovery and development of marine natural products. However, the discovery of microorganisms producing secondary metabolites previously attributed to an invertebrate host poses a significant challenge. This study describes an efficient chemical screening method utilizing a 96-well plate-based bacterial cultivation strategy to identify and isolate microbial producers of marine invertebrate-associated metabolites.
Evaluation of volatile organic emissions from hazardous waste incinerators.
Sedman, R M; Esparza, J R
1991-01-01
Conventional methods of risk assessment typically employed to evaluate the impact of hazardous waste incinerators on public health must rely on somewhat speculative emissions estimates or on complicated and expensive sampling and analytical methods. The limited amount of toxicological information concerning many of the compounds detected in stack emissions also complicates the evaluation of the public health impacts of these facilities. An alternative approach aimed at evaluating the public health impacts associated with volatile organic stack emissions is presented that relies on a screening criterion to evaluate total stack hydrocarbon emissions. If the concentration of hydrocarbons in ambient air is below the screening criterion, volatile emissions from the incinerator are judged not to pose a significant threat to public health. Both the screening criterion and a conventional method of risk assessment were employed to evaluate the emissions from 20 incinerators. Use of the screening criterion always yielded a substantially greater estimate of risk than that derived by the conventional method. Since the use of the screening criterion always yielded estimates of risk that were greater than that determined by conventional methods and measuring total hydrocarbon emissions is a relatively simple analytical procedure, the use of the screening criterion would appear to facilitate the evaluation of operating hazardous waste incinerators. PMID:1954928
Cervical cancer screening programs in Latin America and the Caribbean.
Murillo, Raul; Almonte, Maribel; Pereira, Ana; Ferrer, Elena; Gamboa, Oscar A; Jerónimo, José; Lazcano-Ponce, Eduardo
2008-08-19
Latin America and the Caribbean (LAC) have a significant burden of cervical cancer. Prophylactic human papillomavirus (HPV) vaccines are an opportunity for primary prevention and new screening methods, such as new HPV DNA testing, are promising alternatives to cytology screening that should be analyzed in the context of regional preventive programs. Cytology-based screening programs have not fulfilled their expectations and coverage does not sufficiently explain the lack of impact on screening in LAC. While improved evaluation of screening programs is necessary to increase the impact of screening on the reduction of incidence and mortality, other programmatic aspects will need to be addressed such as follow-up of positive tests and quality control. The implementation of new technologies might enhance screening performance and reduce mortality in the region. The characteristics, performance and impact of cervical cancer screening programs in LAC are reviewed in this article.
EJSCREEN Version 1, EJ Index Alternatives
This map service displays alternative environmental justice (EJ) indexes used in EJSCREEN. The alternative EJ indexes combine each of the 12 environmental indicators and one of two demographic indexes using different methods than the Primary EJ Index. EJ Index Alternative 1 is a combination of a blockgroup environmental factor, the populaiton of the blockgroup, and the demographic index. This EJ Index measures how much a particular place contributes to the total burden faced by subpopulations highlighted by the demographic index. EJ Index Alternative 2 is a combination of a blockgroup environmental factor and the demographic index. Two options are presented for both EJ Index Alternative 1 and Alternative 2-- they are combined with the primary demographic index and alternative demographic index. EJSCREEN is an environmental justice screening tool that provides EPA with a nationally consistent approach to screening for potential areas of EJ concern that may warrant further investigation. The EJ indexes are block group level results that combine multiple demographic factors with a single environmental variable (such as proximity to traffic) that can be used to help identify communities living with the greatest potential for negative environmental and health effects. The EJSCREEN tool is currently for internal EPA use only. It is anticipated that as users become accustomed to this new tool, individual programs within the Agency will develop program use guidelines a
Evaluation of a Noncontact, Alternative Mosquito Repellent Assay System.
Tisgratog, Rungarun; Kongmee, Monthathip; Sanguanpong, Unchalee; Prabaripai, Atchariya; Bangs, Michael J; Chareonviriyaphap, Theeraphap
2016-09-01
A novel noncontact repellency assay system (NCRAS) was designed and evaluated as a possible alternative method for testing compounds that repel or inhibit mosquitoes from blood feeding. Deet and Aedes aegypti were used in a controlled laboratory setting. Using 2 study designs, a highly significant difference were seen between deet-treated and untreated skin placed behind the protective screens, indicating that deet was detected and was acting as a deterrence to mosquito landing and probing behavior. However, a 2nd study showed significant differences between protected (behind a metal screen barrier) and unprotected (exposed) deet-treated forearms, indicating the screen mesh might restrict the detection of deet and thus influences landing/biting response. These findings indicate the prototype NCRAS shows good promise but requires further evaluation and possible modification in design and testing protocol to achieve more desirable operational attributes in comparison with direct skin-contact repellency mosquito assays.
Online advertising by three commercial breast imaging services: message takeout and effectiveness.
Johnson, Rebecca; Jalleh, Geoffrey; Pratt, Iain S; Donovan, Robert J; Lin, Chad; Saunders, Christobel; Slevin, Terry
2013-10-01
Mammography is widely acknowledged to be the most cost-effective technique for population screening for breast cancer. Recently in Australia, imaging modalities other than mammography, including thermography, electrical impedance, and computerised breast imaging, have been increasingly promoted as alternative methods of breast cancer screening. This study assessed the impact of three commercial breast imaging companies' promotional material upon consumers' beliefs about the effectiveness of the companies' technology in detecting breast cancer, and consumers' intentions to seek more information or consider having their breasts imaged by these modalities. Results showed 90% of respondents agreed that the companies' promotional material promoted the message that the advertised breast imaging method was effective in detecting breast cancer, and 80% agreed that the material promoted the message that the imaging method was equally or more effective than a mammogram. These findings have implications for women's preference for and uptake of alternative breast imaging services over mammography. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Drwal, Malgorzata N.; Agama, Keli; Pommier, Yves; Griffith, Renate
2013-12-01
Purely structure-based pharmacophores (SBPs) are an alternative method to ligand-based approaches and have the advantage of describing the entire interaction capability of a binding pocket. Here, we present the development of SBPs for topoisomerase I, an anticancer target with an unusual ligand binding pocket consisting of protein and DNA atoms. Different approaches to cluster and select pharmacophore features are investigated, including hierarchical clustering and energy calculations. In addition, the performance of SBPs is evaluated retrospectively and compared to the performance of ligand- and complex-based pharmacophores. SBPs emerge as a valid method in virtual screening and a complementary approach to ligand-focussed methods. The study further reveals that the choice of pharmacophore feature clustering and selection methods has a large impact on the virtual screening hit lists. A prospective application of the SBPs in virtual screening reveals that they can be used successfully to identify novel topoisomerase inhibitors.
BIOLOGICALLY-BASED RAPID SCREENING METHODS FOR DIOXINS IN THE UNITED STATES
Because of the extensive cost, in personnel, time, equipment, and money to measure dioxin-like chemicals analytically, alternative technologies have been developed to measure the integrated sum of the activity of the dioxin-like chemicals.
Rajan, Shobana; Khanna, Ashish; Argalious, Maged; Kimatian, Stephen J; Mascha, Edward J; Makarova, Natalya; Nada, Eman M; Elsharkawy, Hesham; Firoozbakhsh, Farhad; Avitsian, Rafi
2016-02-01
Simulation-based learning is emerging as an alternative educational tool in this era of a relative shortfall of teaching anesthesiologists. The objective of the study is to assess whether screen-based (interactive computer simulated) case scenarios are more effective than problem-based learning discussions (PBLDs) in improving test scores 4 and 8 weeks after these interventions in anesthesia residents during their first neuroanesthesia rotation. Prospective, nonblinded quasi-crossover study. Cleveland Clinic. Anesthesiology residents. Two case scenarios were delivered from the Anesoft software as screen-based sessions, and parallel scripts were developed for 2 PBLDs. Each resident underwent both types of training sessions, starting with the PBLD session, and the 2 cases were alternated each month (ie, in 1 month, the screen-based intervention used case 1 and the PBLD used case 2, and vice versa for the next month). Test scores before the rotation (baseline), immediately after the rotation (4 weeks after the start of the rotation), and 8 weeks after the start of rotation were collected on each topic from each resident. The effect of training method on improvement in test scores was assessed using a linear mixed-effects model. Compared to the departmental standard of PBLD, the simulation method did not improve either the 4- or 8-week mean test scores (P = .41 and P = .40 for training method effect on 4- and 8-week scores, respectively). Resident satisfaction with the simulation module on a 5-point Likert scale showed subjective evidence of a positive impact on resident education. Screen-based simulators were not more effective than PBLD for education during the neuroanesthesia rotation in anesthesia residency. Copyright © 2016 Elsevier Inc. All rights reserved.
Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone.
Harvey, Virginia L; Egerton, Victoria M; Chamberlain, Andrew T; Manning, Phillip L; Buckley, Michael
2016-01-01
Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six (14)C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated (14)C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 1(4)C analysis.
Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone
Harvey, Virginia L.; Egerton, Victoria M.; Chamberlain, Andrew T.; Manning, Phillip L.; Buckley, Michael
2016-01-01
Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six 14C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated 14C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 14C analysis. PMID:26938469
Public stated preferences and predicted uptake for genome-based colorectal cancer screening
2014-01-01
Background Emerging developments in nanomedicine allow the development of genome-based technologies for non-invasive and individualised screening for diseases such as colorectal cancer. The main objective of this study was to measure user preferences for colorectal cancer screening using a nanopill. Methods A discrete choice experiment was used to estimate the preferences for five competing diagnostic techniques including the nanopill and iFOBT. Alternative screening scenarios were described using five attributes namely: preparation involved, sensitivity, specificity, complication rate and testing frequency. Fourteen random and two fixed choice tasks, each consisting of three alternatives, were offered to 2225 individuals. Data were analysed using the McFadden conditional logit model. Results Thirteen hundred and fifty-six respondents completed the questionnaire. The most important attributes (and preferred levels) were the screening technique (nanopill), sensitivity (100%) and preparation (no preparation). Stated screening uptake for the nanopill was 79%, compared to 76% for iFOBT. In the case of screening with the nanopill, the percentage of people preferring not to be screened would be reduced from 19.2% (iFOBT) to 16.7%. Conclusions Although the expected benefits of nanotechnology based colorectal cancer screening are improved screening uptake, assuming more accurate test results and less preparation involved, the relative preference of the nanopill is only slightly higher than the iFOBT. Estimating user preferences during the development of diagnostic technologies could be used to identify relative performance, including perceived benefits and harms compared to competitors allowing for significant changes to be made throughout the process of development. PMID:24642027
Application of Adverse Outcome Pathways to U.S. EPA’s Endocrine Disruptor Screening Program
Noyes, Pamela D.; Casey, Warren M.; Dix, David J.
2017-01-01
Background: The U.S. EPA’s Endocrine Disruptor Screening Program (EDSP) screens and tests environmental chemicals for potential effects in estrogen, androgen, and thyroid hormone pathways, and it is one of the only regulatory programs designed around chemical mode of action. Objectives: This review describes the EDSP’s use of adverse outcome pathway (AOP) and toxicity pathway frameworks to organize and integrate diverse biological data for evaluating the endocrine activity of chemicals. Using these frameworks helps to establish biologically plausible links between endocrine mechanisms and apical responses when those end points are not measured in the same assay. Results: Pathway frameworks can facilitate a weight of evidence determination of a chemical’s potential endocrine activity, identify data gaps, aid study design, direct assay development, and guide testing strategies. Pathway frameworks also can be used to evaluate the performance of computational approaches as alternatives for low-throughput and animal-based assays and predict downstream key events. In cases where computational methods can be validated based on performance, they may be considered as alternatives to specific assays or end points. Conclusions: A variety of biological systems affect apical end points used in regulatory risk assessments, and without mechanistic data, an endocrine mode of action cannot be determined. Because the EDSP was designed to consider mode of action, toxicity pathway and AOP concepts are a natural fit. Pathway frameworks have diverse applications to endocrine screening and testing. An estrogen pathway example is presented, and similar approaches are being used to evaluate alternative methods and develop predictive models for androgen and thyroid pathways. https://doi.org/10.1289/EHP1304 PMID:28934726
Veronesi, Giulia; Colombo, Paolo; Novellis, Pierluigi; Crepaldi, Alessandro; Lutman, Romano Fabio; Dieci, Elisa; Profili, Manuel; Siracusano, Licia; Alloisio, Marco
2017-03-01
Widespread lung cancer screening with low-dose computed tomography is urgently needed in Europe to identify lung cancers early and reduce lung cancer deaths. The most effective method of identifying high-risk individuals and recruiting them for screening has not been determined. In the present pilot study we investigated direct telephoning to families as a way of identifying high risk individuals and recruiting them to a screening/smoking cessation program, that avoided the selection bias of voluntary screening. Families in the province of Milan, Italy, were contacted by telephone at their homes and asked about family members over 50 years who were heavy smokers (30 or more pack-years). Persons meeting these criteria were contacted and asked to participate in the program. Those who agreed were given an appointment to undergo screening and receive smoking cessation counseling. Among the 1000 contacted families, involving 2300 persons, 44 (1.9%) were eligible for LDCT screening, and 12 (27%) of these participated in the program. The cost of this recruitment strategy pilot study was around 150 euro per screened subject. We obtained useful information on the proportion of the general population eligible for lung cancer screening and the proportion of those who responded. However the cost of home telephone calling is probably too high to be practicable as a method of recruiting high risk persons for screening. Alternative recruitment methods, possibly involving family physicians practitioners, need to be investigated. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.
Doyle, Kelly; Strathmann, Frederick G
2017-02-01
This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.
de Brugerolle, Anne
2007-01-01
SkinEthic Laboratories is a France-based biotechnology company recognised as the world leader in tissue engineering. SkinEthic is devoted to develop and produce reliable and robust in vitro alternative methods to animal use in cosmetic, chemical and pharmaceutical industries. SkinEthic models provide relevant tools for efficacy and safety screening tests in order to support an integrated decision-making during research and development phases. Some screening tests are referenced and validated as alternatives to animal use (Episkin), others are in the process of validation under ECVAM and OECD guidelines. SkinEthic laboratories provide a unique and joined experience of more than 20 years from Episkin SNC and SkinEthic SA. Their unique cell culture process allows in vitro reconstructed human tissues with well characterized histology, functionality and ultrastructure features to be mass produced. Our product line includes skin models: a reconstructed human epidermis with a collagen layer, Episkin, reconstructed human epidermis without or with melanocytes (with a tanning degree from phototype II to VI) and a reconstructed human epithelium, i.e. cornea, and other mucosa, i.e. oral, gingival, oesophageal and vaginal. Our philosophy is based on 3 main commitments: to support our customers by providing robust and reliable models, to ensure training and education in using validated protocols, allowing a large array of raw materials, active ingredients and finished products in solid, liquid, powder, cream or gel form to be screened, and, to provide a dedicated service to our partners.
Crockford, Christopher; Newton, Judith; Lonergan, Katie; Madden, Caoifa; Mays, Iain; O'Sullivan, Meabhdh; Costello, Emmet; Pinto-Grau, Marta; Vajda, Alice; Heverin, Mark; Pender, Niall; Al-Chalabi, Ammar; Hardiman, Orla; Abrahams, Sharon
2018-02-01
Cognitive impairment affects approximately 50% of people with amyotrophic lateral sclerosis (ALS). Research has indicated that impairment may worsen with disease progression. The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) was designed to measure neuropsychological functioning in ALS, with its alternate forms (ECAS-A, B, and C) allowing for serial assessment over time. The aim of the present study was to establish reliable change scores for the alternate forms of the ECAS, and to explore practice effects and test-retest reliability of the ECAS's alternate forms. Eighty healthy participants were recruited, with 57 completing two and 51 completing three assessments. Participants were administered alternate versions of the ECAS serially (A-B-C) at four-month intervals. Intra-class correlation analysis was employed to explore test-retest reliability, while analysis of variance was used to examine the presence of practice effects. Reliable change indices (RCI) and regression-based methods were utilized to establish change scores for the ECAS alternate forms. Test-retest reliability was excellent for ALS Specific, ALS Non-Specific, and ECAS Total scores of the combined ECAS A, B, and C (all > .90). No significant practice effects were observed over the three testing sessions. RCI and regression-based methods produced similar change scores. The alternate forms of the ECAS possess excellent test-retest reliability in a healthy control sample, with no significant practice effects. The use of conservative RCI scores is recommended. Therefore, a change of ≥8, ≥4, and ≥9 for ALS Specific, ALS Non-Specific, and ECAS Total score is required for reliable change.
20180312 - Mechanistic Modeling of Developmental Defects through Computational Embryology (SOT)
Significant advances in the genome sciences, in automated high-throughput screening (HTS), and in alternative methods for testing enable rapid profiling of chemical libraries for quantitative effects on diverse cellular activities. While a surfeit of HTS data and information is n...
Reverse screening methods to search for the protein targets of chemopreventive compounds
NASA Astrophysics Data System (ADS)
Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan
2018-05-01
This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction.
Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds.
Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan
2018-01-01
This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction.
Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds
Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan
2018-01-01
This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction. PMID:29868550
NASA Astrophysics Data System (ADS)
Deka, Jashmini; Mojumdar, Aditya; Parisse, Pietro; Onesti, Silvia; Casalis, Loredana
2017-03-01
Helicase are essential enzymes which are widespread in all life-forms. Due to their central role in nucleic acid metabolism, they are emerging as important targets for anti-viral, antibacterial and anti-cancer drugs. The development of easy, cheap, fast and robust biochemical assays to measure helicase activity, overcoming the limitations of the current methods, is a pre-requisite for the discovery of helicase inhibitors through high-throughput screenings. We have developed a method which exploits the optical properties of DNA-conjugated gold nanoparticles (AuNP) and meets the required criteria. The method was tested with the catalytic domain of the human RecQ4 helicase and compared with a conventional FRET-based assay. The AuNP-based assay produced similar results but is simpler, more robust and cheaper than FRET. Therefore, our nanotechnology-based platform shows the potential to provide a useful alternative to the existing conventional methods for following helicase activity and to screen small-molecule libraries as potential helicase inhibitors.
An update in breast cancer screening and management.
Warrier, Sanjay; Tapia, Grace; Goltsman, David; Beith, Jane
2016-01-01
This article provides an overview of the main controversies in a number of key areas of breast cancer management. Relevant studies that have contributed to guide the treatment of this heterogeneous disease in the field of breast screening, surgery, chemotherapy and radiotherapy are highlighted. Mammography and ultrasound are the main methods of breast screening. MRI and tomosynthesis are emerging as new screening tools for a selected group of breast cancer patients. From a surgical perspective, oncoplastic techniques and neoadjuvant chemotherapy are improving cosmetic results in breast-conserving surgery. For high-risk patients, controversies still remain regarding prophylactic mastectomies. Finally, the appropriate management of the axilla continues evolving with the increasing role of radiotherapy as an alternative treatment to axillary dissection.
An Update in Breast Cancer Screening and Management
Warrier, Sanjay; Tapia, Grace; Goltsman, David; Beith, Jane
2015-01-01
This article provides an overview of the main controversies in a number of key areas of breast cancer management. Relevant studies that have contributed to guide the treatment of this heterogeneous disease in the field of breast screening, surgery, chemotherapy and radiotherapy are highlighted. Mammography and ultrasound are the main methods of breast screening. MRI and tomosynthesis are emerging as new screening tools for a selected group of breast cancer patients. From a surgical perspective, oncoplastic techniques and neoadjuvant chemotherapy are improving cosmetic results in breast-conserving surgery. For high-risk patients, controversies still remain regarding prophylactic mastectomies. Finally, the appropriate management of the axilla continues evolving with the increasing role of radiotherapy as an alternative treatment to axillary dissection. PMID:26689336
NASA Technical Reports Server (NTRS)
Brock, T. W.; Field, M. B.
1979-01-01
Low-melting phosphate and borate glasses were screen printed on silicon wafers and heated to form n and p junctions. Data on surface appearance, sheet resistance and junction depth are presented. Similar data are reported for vapor phase transport from sintered aluminum metaphosphate and boron-containing glass-ceramic solid sources. Simultaneous diffusion of an N(+) layer with screen-printed glass and a p(+) layer with screen-printed Al alloy paste was attempted. No p(+) back surface field formation was achieved. Some good cells were produced but the heating in an endless-belt furnace caused a large scatter in sheet resistance and junction depth for three separate lots of wafers.
Readiness to perform testing : a critical analysis of the concept and current practices.
DOT National Transportation Integrated Search
1993-08-01
Readiness to Perform (RTP) testing has become an increasingly popular alternative to biochemical screening as a method for assessing risk factors (i.e., drug, alcohol, fatigue, etc.) in the workplace. The focus of RTP testing is on the assessment of ...
Mutagenicity and carcinogenicity are endpoints of major environmental and regulatory concern. These endpoints are also important targets for development of alternative methods for screening and prediction due to the large number of chemicals of potential concern and the tremendou...
DOT National Transportation Integrated Search
1992-01-01
This study was conducted to assess an FAA program to hire former military air traffic control specialists to enter ATC field training directly without first attending the Academy screening program. Selection of military controllers was based on meeti...
Mutagenicity and carcinogenicity are endpoints of major environmental and regulatory concern. These endpoints are also important targets for development of alternative methods for screening and prediction due to the large number of chemicals of potential concern and the tremendou...
Dal Bosco, Chiara; Panero, Stefania; Navarra, Maria Assunta; Tomai, Pierpaolo; Curini, Roberta; Gentili, Alessandra
2018-05-30
Adulteration of Mozzarella di Bufala Campana with cow milk is a common fraud because of the high price and limited seasonal availability of water buffalo milk. To identify such adulteration, this work proposes a novel approach based on the use of species-specific, low-molecular-weight biomarkers (LMWBs). Liquid chromatography-tandem mass spectrometry screening analyses identified β-carotene, lutein, and β-cryptoxanthin as LMWBs of cow milk, while ergocalciferol was found only in water buffalo milk. Adulterated mozzarellas were prepared in the laboratory and analyzed for the four biomarkers. Combined quantification of β-carotene and ergocalciferol enabled the detection of cow milk with a sensitivity threshold of 5% (w/w). The method was further tested by analyzing a certificated water buffalo mozzarella and several commercial products. This approach is alternative to conventional proteomic and genomic methods and is advantageous for routine operations as a result of its simplicity, speed, and low cost.
Can data-driven benchmarks be used to set the goals of healthy people 2010?
Allison, J; Kiefe, C I; Weissman, N W
1999-01-01
OBJECTIVES: Expert panels determined the public health goals of Healthy People 2000 subjectively. The present study examined whether data-driven benchmarks provide a better alternative. METHODS: We developed the "pared-mean" method to define from data the best achievable health care practices. We calculated the pared-mean benchmark for screening mammography from the 1994 National Health Interview Survey, using the metropolitan statistical area as the "provider" unit. Beginning with the best-performing provider and adding providers in descending sequence, we established the minimum provider subset that included at least 10% of all women surveyed on this question. The pared-mean benchmark is then the proportion of women in this subset who received mammography. RESULTS: The pared-mean benchmark for screening mammography was 71%, compared with the Healthy People 2000 goal of 60%. CONCLUSIONS: For Healthy People 2010, benchmarks derived from data reflecting the best available care provide viable alternatives to consensus-derived targets. We are currently pursuing additional refinements to the data-driven pared-mean benchmark approach. PMID:9987466
Building a virtual ligand screening pipeline using free software: a survey.
Glaab, Enrico
2016-03-01
Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. © The Author 2015. Published by Oxford University Press.
Building a virtual ligand screening pipeline using free software: a survey
2016-01-01
Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. PMID:26094053
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Sampson, Michael J.
2017-01-01
As the space business rapidly evolves to accommodate a lower cost model of development and operation via concepts such as commercial space and small spacecraft (aka, CubeSats and swarms), traditional EEE parts screening and qualification methods are being scrutinized under a risk-reward trade space. In this presentation, two basic concepts will be discussed: (1) The movement from complete risk aversion EEE parts methods to managing and/or accepting risk via alternate approaches; and, (2) A discussion of emerging assurance methods to reduce overdesign as well emerging model based mission assurance (MBMA) concepts. center dot Example scenarios will be described as well as consideration for trading traditional versus alternate methods.
Rapid Screening for Deleted Form of β-thalassemia by Real-Time Quantitative PCR.
Ke, Liang-Yin; Chang, Jan-Gowth; Chang, Chao-Sung; Hsieh, Li-Ling; Liu, Ta-Chih
2017-01-01
Thalassemia is the most common single gene disease in human beings. The prevalence rate of β-thalassemia in Taiwan is approximately 1-3%. Previously methods to reveal and diagnose severe deleted form of α- or β-thalassemia were insufficient and inappropriate for prenatal diagnosis. A real-time quantitative PCR method was set up for rapid screening of the deleted form of β-thalassemia. Our results show that ΔΔCt between deleted form of β-thalassemia and normal individuals were 1.0674 ± 0.0713. On the contrary, mutation form β-thalassemia showed no difference with normal healthy control. The HBB/CCR5 ratio for deleted form of β-thalassemia patients was 0.48, whether normal individuals and mutation form of β-thalassemia was 1.0. This RQ-PCR technique is an alternative rapid screening assay for deleted form of β-thalassemia. In addition, it could also identify undefined type. Our technique by using RQ-PCR to quantify gene copies is a reliable and time-saving method that can screen deleted form of β-thalassemia. © 2016 Wiley Periodicals, Inc.
Microseed matrix screening for optimization in protein crystallization: what have we learned?
D'Arcy, Allan; Bergfors, Terese; Cowan-Jacob, Sandra W; Marsh, May
2014-09-01
Protein crystals obtained in initial screens typically require optimization before they are of X-ray diffraction quality. Seeding is one such optimization method. In classical seeding experiments, the seed crystals are put into new, albeit similar, conditions. The past decade has seen the emergence of an alternative seeding strategy: microseed matrix screening (MMS). In this strategy, the seed crystals are transferred into conditions unrelated to the seed source. Examples of MMS applications from in-house projects and the literature include the generation of multiple crystal forms and different space groups, better diffracting crystals and crystallization of previously uncrystallizable targets. MMS can be implemented robotically, making it a viable option for drug-discovery programs. In conclusion, MMS is a simple, time- and cost-efficient optimization method that is applicable to many recalcitrant crystallization problems.
Microseed matrix screening for optimization in protein crystallization: what have we learned?
D’Arcy, Allan; Bergfors, Terese; Cowan-Jacob, Sandra W.; Marsh, May
2014-01-01
Protein crystals obtained in initial screens typically require optimization before they are of X-ray diffraction quality. Seeding is one such optimization method. In classical seeding experiments, the seed crystals are put into new, albeit similar, conditions. The past decade has seen the emergence of an alternative seeding strategy: microseed matrix screening (MMS). In this strategy, the seed crystals are transferred into conditions unrelated to the seed source. Examples of MMS applications from in-house projects and the literature include the generation of multiple crystal forms and different space groups, better diffracting crystals and crystallization of previously uncrystallizable targets. MMS can be implemented robotically, making it a viable option for drug-discovery programs. In conclusion, MMS is a simple, time- and cost-efficient optimization method that is applicable to many recalcitrant crystallization problems. PMID:25195878
Predictive Fusion of Geophysical Waveforms using Fisher's Method, under the Alternative Hypothesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carmichael, Joshua Daniel; Nemzek, Robert James; Webster, Jeremy David
2017-05-05
This presentation tries to understand how to combine different signatures from an event or source together in a defensible way. The objective was to build a digital detector that continuously combines detection statistics recording explosions to screen sources of interest from null sources.
Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics
RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.
2015-01-01
BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665
Blacket, Mark J; Malipatil, Mali B; Semeraro, Linda; Gillespie, Peter S; Dominiak, Bernie C
2017-04-01
Understanding the relationship between incursions of insect pests and established populations is critical to implementing effective control. Studies of genetic variation can provide powerful tools to examine potential invasion pathways and longevity of individual pest outbreaks. The major fruit fly pest in eastern Australia, Queensland fruit fly Bactrocera tryoni (Froggatt), has been subject to significant long-term quarantine and population reduction control measures in the major horticulture production areas of southeastern Australia, at the species southern range limit. Previous studies have employed microsatellite markers to estimate gene flow between populations across this region. In this study, we used an independent genetic marker, mitochondrial DNA (mtDNA) sequences, to screen genetic variation in established and adjacent outbreak populations in southeastern Australia. During the study period, favorable environmental conditions resulted in multiple outbreaks, which appeared genetically distinctive and relatively geographically localized, implying minimal dispersal between simultaneous outbreaks. Populations in established regions were found to occur over much larger areas. Screening mtDNA (female) lineages proved to be an effective alternative genetic tool to assist in understanding fruit fly population dynamics and provide another possible molecular method that could now be employed for better understanding of the ecology and evolution of this and other pest species.
Boudreau, Valérie; Reynaud, Quitterie; Dubois, Catherine Lehoux; Coriati, Adèle; Desjardins, Katherine; Durieu, Isabelle; Rabasa-Lhoret, Rémi
2016-10-01
Nearly 50% of adult patients with cystic fibrosis (CF) have diabetes. The occurrence of CF-related diabetes (CFRD) is preceded and is associated with deterioration of lung function and nutritional status. Microvascular complications can occur, but the main cause of death is respiratory failure rather than cardiovascular causes as in type 1 or type 2 diabetes. Because other methods such as glycated hemoglobin (A1C) levels are less sensitive in patients with CF, the recommended screening test is the oral glucose tolerance test (OGTT) with a 75 g glucose dose. However, OGTT is poorly suited for patients with CF, who are already facing a high disease-care burden, and appropriate CF-glucose cut-off for diagnosis and prognosis are also questioned. Thus, alternative screening methods are compared to the classical test (2-hour OGTT), including shorter OGTTs and continuous glucose monitoring. Moreover, many challenges complicate the screening for diabetes such as the complex medical care time for a patient, which is reflected by low adherence to screening tests. The best screening test should take into account the particularities of CFRD and the complexity of the CF medical care. Copyright © 2016 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
Thomas, Duncan C
2017-07-01
Screening behavior depends on previous screening history and family members' behaviors, which can act as both confounders and intermediate variables on a causal pathway from screening to disease risk. Conventional analyses that adjust for these variables can lead to incorrect inferences about the causal effect of screening if high-risk individuals are more likely to be screened. Analyzing the data in a manner that treats screening as randomized conditional on covariates allows causal parameters to be estimated; inverse probability weighting based on propensity of exposure scores is one such method considered here. I simulated family data under plausible models for the underlying disease process and for screening behavior to assess the performance of alternative methods of analysis and whether a targeted screening approach based on individuals' risk factors would lead to a greater reduction in cancer incidence in the population than a uniform screening policy. Simulation results indicate that there can be a substantial underestimation of the effect of screening on subsequent cancer risk when using conventional analysis approaches, which is avoided by using inverse probability weighting. A large case-control study of colonoscopy and colorectal cancer from Germany shows a strong protective effect of screening, but inverse probability weighting makes this effect even stronger. Targeted screening approaches based on either fixed risk factors or family history yield somewhat greater reductions in cancer incidence with fewer screens needed to prevent one cancer than population-wide approaches, but the differences may not be large enough to justify the additional effort required. See video abstract at, http://links.lww.com/EDE/B207.
Estimating the cost of cervical cancer screening in five developing countries
Goldhaber-Fiebert, Jeremy D; Goldie, Sue J
2006-01-01
Background Cost-effectiveness analyses (CEAs) can provide useful information to policymakers concerned with the broad allocation of resources as well as to local decision makers choosing between different options for reducing the burden from a single disease. For the latter, it is important to use country-specific data when possible and to represent cost differences between countries that might make one strategy more or less attractive than another strategy locally. As part of a CEA of cervical cancer screening in five developing countries, we supplemented limited primary cost data by developing other estimation techniques for direct medical and non-medical costs associated with alternative screening approaches using one of three initial screening tests: simple visual screening, HPV DNA testing, and cervical cytology. Here, we report estimation methods and results for three cost areas in which data were lacking. Methods To supplement direct medical costs, including staff, supplies, and equipment depreciation using country-specific data, we used alternative techniques to quantify cervical cytology and HPV DNA laboratory sample processing costs. We used a detailed quantity and price approach whose face validity was compared to an adaptation of a US laboratory estimation methodology. This methodology was also used to project annual sample processing capacities for each laboratory type. The cost of sample transport from the clinic to the laboratory was estimated using spatial models. A plausible range of the cost of patient time spent seeking and receiving screening was estimated using only formal sector employment and wages as well as using both formal and informal sector participation and country-specific minimum wages. Data sources included primary data from country-specific studies, international databases, international prices, and expert opinion. Costs were standardized to year 2000 international dollars using inflation adjustment and purchasing power parity. Results Cervical cytology laboratory processing costs were I$1.57–3.37 using the quantity and price method compared to I$1.58–3.02 from the face validation method. HPV DNA processing costs were I$6.07–6.59. Rural laboratory transport costs for cytology were I$0.12–0.64 and I$0.14–0.74 for HPV DNA laboratories. Under assumptions of lower resource efficiency, these estimates increased to I$0.42–0.83 and I$0.54–1.06. Estimates of the value of an hour of patient time using only formal sector participation were I$0.07–4.16, increasing to I$0.30–4.80 when informal and unpaid labor was also included. The value of patient time for traveling, waiting, and attending a screening visit was I$0.68–17.74. With the total cost of screening for cytology and HPV DNA testing ranging from I$4.85–40.54 and I$11.30–48.77 respectively, the cost of the laboratory transport, processing, and patient time accounted for 26–66% and 33–65% of the total costs. From a payer perspective, laboratory transport and processing accounted for 18–48% and 25–60% of total direct medical costs of I$4.11–19.96 and I$10.57–28.18 respectively. Conclusion Cost estimates of laboratory processing, sample transport, and patient time account for a significant proportion of total cervical cancer screening costs in five developing countries and provide important inputs for CEAs of alternative screening modalities. PMID:16887041
Automated solar collector installation design
Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules
2014-08-26
Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre-defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives.
A review of screening mammography participation and utilization in Canada.
Doyle, G P; Major, D; Chu, C; Stankiewicz, A; Harrison, M L; Pogany, L; Mai, V M; Onysko, J
2011-09-01
Participation rate is an important indicator for a screening program's effectiveness; however, the current approach to measuring participation rate in Canada is not comparable with other countries. The objective of this study is to review the measurement of screening mammography participation in Canada, make international comparisons, and propose alternative methods. Canadian breast cancer screening program data for women aged 50 to 69 years screened between 2004 and 2006 were extracted from the Canadian Breast Cancer Screening Database (CBCSD). The fee-for-services (FSS) mammography data (opportunistic screening mammography) were obtained from the provincial ministries of health. Both screening mammography program participation and utilization were examined over 24 and 30 months. Canada's screening participation rate increases from 39.4% for a 24-month cut-off to 43.6% for a 30-month cut-off. The 24-month mammography utilization rate is 63.1% in Canada, and the 30-month utilization rate is 70.4%. Due to the differences in health service delivery among Canadian provinces, both programmatic participation and overall utilization of mammography at 24 months and 30 months should be monitored.
Development and Validation of Cognitive Screening Instruments.
ERIC Educational Resources Information Center
Jarman, Ronald F.
The author suggests that most research on the early detection of learning disabilities is characterisized by an ineffective and a theoretical method of selecting and validating tasks. An alternative technique is proposed, based on a neurological theory of cognitive processes, whereby task analysis is a first step, with empirical analyses as…
Given the minimal developmental neurotoxicity data available for the large number of new and existing chemicals, there is a critical need for alternative methods to identify and prioritize chemicals for further testing. We outline a developmental neurotoxicity screening approach ...
Screening fusarium resistant rootstocks for plant parasitic nematode resistance
USDA-ARS?s Scientific Manuscript database
The phase out of methyl bromide has directed research toward alternative methods of managing soil-borne pathogens. A limiting factor in many watermelon producing regions is Fusarium wilt caused by the soil-borne fungi Fusarium oxysporum f.sp. niveum (FON). There is no varietal resistance to FON depl...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poludniowski, Gavin G.; Evans, Philip M.
2013-04-15
Purpose: Monte Carlo methods based on the Boltzmann transport equation (BTE) have previously been used to model light transport in powdered-phosphor scintillator screens. Physically motivated guesses or, alternatively, the complexities of Mie theory have been used by some authors to provide the necessary inputs of transport parameters. The purpose of Part II of this work is to: (i) validate predictions of modulation transform function (MTF) using the BTE and calculated values of transport parameters, against experimental data published for two Gd{sub 2}O{sub 2}S:Tb screens; (ii) investigate the impact of size-distribution and emission spectrum on Mie predictions of transport parameters; (iii)more » suggest simpler and novel geometrical optics-based models for these parameters and compare to the predictions of Mie theory. A computer code package called phsphr is made available that allows the MTF predictions for the screens modeled to be reproduced and novel screens to be simulated. Methods: The transport parameters of interest are the scattering efficiency (Q{sub sct}), absorption efficiency (Q{sub abs}), and the scatter anisotropy (g). Calculations of these parameters are made using the analytic method of Mie theory, for spherical grains of radii 0.1-5.0 {mu}m. The sensitivity of the transport parameters to emission wavelength is investigated using an emission spectrum representative of that of Gd{sub 2}O{sub 2}S:Tb. The impact of a grain-size distribution in the screen on the parameters is investigated using a Gaussian size-distribution ({sigma}= 1%, 5%, or 10% of mean radius). Two simple and novel alternative models to Mie theory are suggested: a geometrical optics and diffraction model (GODM) and an extension of this (GODM+). Comparisons to measured MTF are made for two commercial screens: Lanex Fast Back and Lanex Fast Front (Eastman Kodak Company, Inc.). Results: The Mie theory predictions of transport parameters were shown to be highly sensitive to both grain size and emission wavelength. For a phosphor screen structure with a distribution in grain sizes and a spectrum of emission, only the average trend of Mie theory is likely to be important. This average behavior is well predicted by the more sophisticated of the geometrical optics models (GODM+) and in approximate agreement for the simplest (GODM). The root-mean-square differences obtained between predicted MTF and experimental measurements, using all three models (GODM, GODM+, Mie), were within 0.03 for both Lanex screens in all cases. This is excellent agreement in view of the uncertainties in screen composition and optical properties. Conclusions: If Mie theory is used for calculating transport parameters for light scattering and absorption in powdered-phosphor screens, care should be taken to average out the fine-structure in the parameter predictions. However, for visible emission wavelengths ({lambda} < 1.0 {mu}m) and grain radii (a > 0.5 {mu}m), geometrical optics models for transport parameters are an alternative to Mie theory. These geometrical optics models are simpler and lead to no substantial loss in accuracy.« less
Grimes, D.J.; Marranzino, A.P.
1968-01-01
Two spectrographic methods are used in mobile field laboratories of the U. S. Geological Survey. In the direct-current arc method, the ground sample is mixed with graphite powder, packed into an electrode crater, and burned to completion. Thirty elements are determined. In the spark method, the sample, ground to pass a 150-mesh screen, is digested in hydrofluoric acid followed by evaporation to dryness and dissolution in aqua regia. The solution is fed into the spark gap by means of a rotating-disk electrode arrangement and is excited with an alternating-current spark discharge. Fourteen elements are determined. In both techniques, light is recorded on Spectrum Analysis No. 1, 35-millimeter film, and the spectra are compared visually with those of standard films.
Dioxins in beef samples from Mexico using a low resolution GC/MS screening method.
Naccha, Lidia; Alanis, Guadalupe; Torres, Anabel; Abad, Esteban; Ábalos, Manuela; Rivera, Josep; Heyer, Lorenzo; Morales, Alberto; Waksman, Noemí
2010-01-01
Dioxins in beef were quantified by high resolution gas chromatography coupled to low-resolution mass spectrometry (GC/LRMS). The analyses were performed according to the minimum requirements described in the USEPA 1613 method with some minor modifications. Levels found in the samples were in the range 1.02-8.04 pg WHO-TEQ PCDDs/PCDFs g(-1) fat. For comparison purposes, the maximum level allowed by the European Union is 3 pg WHO-TEQ PCDDs/PCDFs g(-1) fat, and some of these samples surpassed the above-mentioned limit and can be considered as contaminated food. The results confirm that a preliminary screening of dioxins in beef can be performed by GC/LRMS. As far as we know, this is the first report of dioxins in beef in Mexico. After the appropriated tests, the applied methodology could be considered as an alternative screening method for the analysis of PCDD/Fs in other food products.
Nordeste, Ricardo F; Trainer, Maria A; Charles, Trevor C
2010-01-01
Development of different PHAs as alternatives to petrochemically derived plastics can be facilitated by mining metagenomic libraries for diverse PHA cycle genes that might be useful for synthesis of bioplastics. The specific phenotypes associated with mutations of the PHA synthesis pathway genes in Sinorhizobium meliloti allows for the use of powerful selection and screening tools to identify complementing novel PHA synthesis genes. Identification of novel genes through their function rather than sequence facilitates finding functional proteins that may otherwise have been excluded through sequence-only screening methodology. We present here methods that we have developed for the isolation of clones expressing novel PHA metabolism genes from metagenomic libraries.
Cheng, Jiujun; Nordeste, Ricardo; Trainer, Maria A; Charles, Trevor C
2017-01-01
Development of different PHAs as alternatives to petrochemically derived plastics can be facilitated by mining metagenomic libraries for diverse PHA cycle genes that might be useful for synthesis of bio-plastics. The specific phenotypes associated with mutations of the PHA synthesis pathway genes in Sinorhizobium meliloti and Pseudomonas putida, allows the use of powerful selection and screening tools to identify complementing novel PHA synthesis genes. Identification of novel genes through their function rather than sequence facilitates the functional proteins that may otherwise have been excluded through sequence-only screening methodology. We present here methods that we have developed for the isolation of clones expressing novel PHA metabolism genes from metagenomic libraries.
Multidimensional Programming Methods for Energy Facility Siting: Alternative Approaches
NASA Technical Reports Server (NTRS)
Solomon, B. D.; Haynes, K. E.
1982-01-01
The use of multidimensional optimization methods in solving power plant siting problems, which are characterized by several conflicting, noncommensurable objectives is addressed. After a discussion of data requirements and exclusionary site screening methods for bounding the decision space, classes of multiobjective and goal programming models are discussed in the context of finite site selection. Advantages and limitations of these approaches are highlighted and the linkage of multidimensional methods with the subjective, behavioral components of the power plant siting process is emphasized.
Adequacy of published screening criteria for retinopathy of prematurity.
Taranath, Deepa A; Oh, Dickson D-S; Keane, Miriam C; Fabel, Helen; Marshall, Peter
2016-03-01
Criteria for screening preterm infants for retinopathy of prematurity vary around the world. We aimed to analyse the efficacy of alternative screening criteria. We collected retrospective data at a tertiary level neonatal nursery. Our participants were 1007 babies, born between 1997 and 2011, at <32 weeks gestational age or <1500 g birth weight (as recommended by the National Health and Medical Research Council in 1996), who had completed follow-up to full retinal vascularization, with defined presence or absence of retinopathy of prematurity. We determined whether disease would be detected using an alternative Australian screening model (gestational age <30 weeks or birth weight <1250 g) or screening criteria utilized in developed countries with similar standards of neonatal care. Detection of retinopathy of prematurity is our main outcome. Using several of the alternative criteria, two neonates with clinically significant retinopathy of prematurity, one of whom required laser treatment to preserve sight, would not have been screened, and their disease may have gone undetected. Use of <30 weeks gestational age or <1500 g birth weight as the criteria would still have screened these infants but would have reduced the number of infants screened by 24.9%. Some commonly utilized international screening criteria for retinopathy of prematurity may risk clinically significant cases being missed and others may screen babies unnecessarily. Alternative criteria should be considered and '<30 weeks gestational age and/or <1500 g birth weight' appears a viable option. © 2015 Royal Australian and New Zealand College of Ophthalmologists.
CRISPR-STOP: gene silencing through base-editing-induced nonsense mutations.
Kuscu, Cem; Parlak, Mahmut; Tufan, Turan; Yang, Jiekun; Szlachta, Karol; Wei, Xiaolong; Mammadov, Rashad; Adli, Mazhar
2017-07-01
CRISPR-Cas9-induced DNA damage may have deleterious effects at high-copy-number genomic regions. Here, we use CRISPR base editors to knock out genes by changing single nucleotides to create stop codons. We show that the CRISPR-STOP method is an efficient and less deleterious alternative to wild-type Cas9 for gene-knockout studies. Early stop codons can be introduced in ∼17,000 human genes. CRISPR-STOP-mediated targeted screening demonstrates comparable efficiency to WT Cas9, which indicates the suitability of our approach for genome-wide functional screenings.
A mix-and-read drop-based in vitro two-hybrid method for screening high-affinity peptide binders
Cui, Naiwen; Zhang, Huidan; Schneider, Nils; Tao, Ye; Asahara, Haruichi; Sun, Zhiyi; Cai, Yamei; Koehler, Stephan A.; de Greef, Tom F. A.; Abbaspourrad, Alireza; Weitz, David A.; Chong, Shaorong
2016-01-01
Drop-based microfluidics have recently become a novel tool by providing a stable linkage between phenotype and genotype for high throughput screening. However, use of drop-based microfluidics for screening high-affinity peptide binders has not been demonstrated due to the lack of a sensitive functional assay that can detect single DNA molecules in drops. To address this sensitivity issue, we introduced in vitro two-hybrid system (IVT2H) into microfluidic drops and developed a streamlined mix-and-read drop-IVT2H method to screen a random DNA library. Drop-IVT2H was based on the correlation between the binding affinity of two interacting protein domains and transcriptional activation of a fluorescent reporter. A DNA library encoding potential peptide binders was encapsulated with IVT2H such that single DNA molecules were distributed in individual drops. We validated drop-IVT2H by screening a three-random-residue library derived from a high-affinity MDM2 inhibitor PMI. The current drop-IVT2H platform is ideally suited for affinity screening of small-to-medium-sized libraries (103–106). It can obtain hits within a single day while consuming minimal amounts of reagents. Drop-IVT2H simplifies and accelerates the drop-based microfluidics workflow for screening random DNA libraries, and represents a novel alternative method for protein engineering and in vitro directed protein evolution. PMID:26940078
Screening Chemicals for Estrogen Receptor Bioactivity Using a Computational Model.
Browne, Patience; Judson, Richard S; Casey, Warren M; Kleinstreuer, Nicole C; Thomas, Russell S
2015-07-21
The U.S. Environmental Protection Agency (EPA) is considering high-throughput and computational methods to evaluate the endocrine bioactivity of environmental chemicals. Here we describe a multistep, performance-based validation of new methods and demonstrate that these new tools are sufficiently robust to be used in the Endocrine Disruptor Screening Program (EDSP). Results from 18 estrogen receptor (ER) ToxCast high-throughput screening assays were integrated into a computational model that can discriminate bioactivity from assay-specific interference and cytotoxicity. Model scores range from 0 (no activity) to 1 (bioactivity of 17β-estradiol). ToxCast ER model performance was evaluated for reference chemicals, as well as results of EDSP Tier 1 screening assays in current practice. The ToxCast ER model accuracy was 86% to 93% when compared to reference chemicals and predicted results of EDSP Tier 1 guideline and other uterotrophic studies with 84% to 100% accuracy. The performance of high-throughput assays and ToxCast ER model predictions demonstrates that these methods correctly identify active and inactive reference chemicals, provide a measure of relative ER bioactivity, and rapidly identify chemicals with potential endocrine bioactivities for additional screening and testing. EPA is accepting ToxCast ER model data for 1812 chemicals as alternatives for EDSP Tier 1 ER binding, ER transactivation, and uterotrophic assays.
Friedman, Allison L; Bloodgood, Bonny
2013-01-01
Annual chlamydia screening is recommended for sexually active women aged 25 years and younger, though less than half of eligible women are screened each year. If acceptable to young women, nontraditional testing venues and new communication technologies could promote efficiencies in sexually transmitted disease (STD) screening and facilitate screening by overcoming barriers at systems and patient levels. This study sought to explore young women's technology use, preferences for STD-testing venues, attitudes toward nontraditional venues, and acceptability of test results delivery options. A total of 80 ethnographic one-on-one telephone interviews were conducted with African American, Caucasian, and Latina women, aged 15 to 25 years, in 10 metropolitan areas of the United States. Interviews were recorded, transcribed, and analyzed using NVivo2. Alternative STD-testing venues and results delivery channels are valued by young women for their convenience and accessibility, but they must also offer privacy, confidentiality, and emotional/informational support to be acceptable. Assuring provider (or self) competence and valid/accurate test results is also important. Although new technologies have been embraced by young women for personal and social uses, they may not be as readily embraced for the provision of STD-related services. Additional social marketing efforts may be needed to promote acceptance of nontraditional STD-testing settings and results delivery methods.
Eklund, Daniel; Welin, Amanda; Schön, Thomas; Stendahl, Olle; Huygen, Kris; Lerm, Maria
2010-01-01
Intracellular pathogens such as Mycobacterium tuberculosis have adapted to a life inside host cells, in which they utilize host nutrients to replicate and spread. Ineffective methods for the evaluation of growth of intracellular pathogens in their true environment pose an obstacle for basic research and drug screening. Here we present the validation of a luminometry-based method for the analysis of intramacrophage growth of M. tuberculosis. The method, which is performed in a medium-throughput format, can easily be adapted for studies of other intracellular pathogens and cell types. The use of host cells in drug-screening assays dedicated to find antimicrobials effective against intracellular pathogens permits the discovery of not only novel antibiotics but also compounds with immunomodulatory and virulence-impairing activities, which may be future alternatives or complements to antibiotics. PMID:20107000
Albu, Silvia A; Al-Karmi, Salma A; Vito, Alyssa; Dzandzi, James P K; Zlitni, Aimen; Beckford-Vera, Denis; Blacker, Megan; Janzen, Nancy; Patel, Ramesh M; Capretta, Alfredo; Valliant, John F
2016-01-20
A convenient method to prepare radioiodinated tetrazines was developed, such that a bioorthogonal inverse electron demand Diels-Alder reaction can be used to label biomolecules with iodine-125 for in vitro screening and in vivo biodistribution studies. The tetrazine was prepared by employing a high-yielding oxidative halo destannylation reaction that concomitantly oxidized the dihydrotetrazine precursor. The product reacts quickly and efficiently with trans-cyclooctene derivatives. Utility was demonstrated through antibody and hormone labeling experiments and by evaluating products using standard analytical methods, in vitro assays, and quantitative biodistribution studies where the latter was performed in direct comparison to Bolton-Hunter and direct iodination methods. The approach described provides a convenient and advantageous alternative to conventional protein iodination methods that can expedite preclinical development and evaluation of biotherapeutics.
A cost-effectiveness analysis of screening for silent atrial fibrillation after ischaemic stroke.
Levin, Lars-Åke; Husberg, Magnus; Sobocinski, Piotr Doliwa; Kull, Viveka Frykman; Friberg, Leif; Rosenqvist, Mårten; Davidson, Thomas
2015-02-01
The purpose of this study was to estimate the cost-effectiveness of two screening methods for detection of silent AF, intermittent electrocardiogram (ECG) recordings using a handheld recording device, at regular time intervals for 30 days, and short-term 24 h continuous Holter ECG, in comparison with a no-screening alternative in 75-year-old patients with a recent ischaemic stroke. The long-term (20-year) costs and effects of all alternatives were estimated with a decision analytic model combining the result of a clinical study and epidemiological data from Sweden. The structure of a cost-effectiveness analysis was used in this study. The short-term decision tree model analysed the screening procedure until the onset of anticoagulant treatment. The second part of the decision model followed a Markov design, simulating the patients' health states for 20 years. Continuous 24 h ECG recording was inferior to intermittent ECG in terms of cost-effectiveness, due to both lower sensitivity and higher costs. The base-case analysis compared intermittent ECG screening with no screening of patients with recent stroke. The implementation of the screening programme on 1000 patients resulted over a 20-year period in 11 avoided strokes and the gain of 29 life-years, or 23 quality-adjusted life years, and cost savings of €55 400. Screening of silent AF by intermittent ECG recordings in patients with a recent ischaemic stroke is a cost-effective use of health care resources saving costs and lives and improving the quality of life. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Tuite, Ashleigh R.; Burchell, Ann N.; Fisman, David N.
2014-01-01
Background Syphilis co-infection risk has increased substantially among HIV-infected men who have sex with men (MSM). Frequent screening for syphilis and treatment of men who test positive might be a practical means of controlling the risk of infection and disease sequelae in this population. Purpose We evaluated the cost-effectiveness of strategies that increased the frequency and population coverage of syphilis screening in HIV-infected MSM receiving HIV care, relative to current standard of care. Methods We developed a state-transition microsimulation model of syphilis natural history and medical care in HIV-infected MSM receiving care for HIV. We performed Monte Carlo simulations using input data derived from a large observational cohort in Ontario, Canada, and from published biomedical literature. Simulations compared usual care (57% of the population screened annually) to different combinations of more frequent (3- or 6-monthly) screening and higher coverage (100% screened). We estimated expected disease-specific outcomes, quality-adjusted survival, costs, and cost-effectiveness associated with each strategy from the perspective of a public health care payer. Results Usual care was more costly and less effective than strategies with more frequent or higher coverage screening. Higher coverage strategies (with screening frequency of 3 or 6 months) were expected to be cost-effective based on usually cited willingness-to-pay thresholds. These findings were robust in the face of probabilistic sensitivity analyses, alternate cost-effectiveness thresholds, and alternate assumptions about duration of risk, program characteristics, and management of underlying HIV. Conclusions We project that higher coverage and more frequent syphilis screening of HIV-infected MSM would be a highly cost-effective health intervention, with many potentially viable screening strategies projected to both save costs and improve health when compared to usual care. The baseline requirement for regular blood testing in this group (i.e., for viral load monitoring) makes intensification of syphilis screening appear readily practicable. PMID:24983455
Classification of human pathogen bacteria for early screening using electronic nose
NASA Astrophysics Data System (ADS)
Zulkifli, Syahida Amani; Mohamad, Che Wan Syarifah Robiah; Abdullah, Abu Hassan
2017-10-01
This paper present human pathogen bacteria for early screening using electronic nose. Electronic nose (E-nose) known as gas sensor array is a device that analyze the odor measurement give the fast response and less time consuming for clinical diagnosis. Many bacterial pathogens could lead to life threatening infections. Accurate and rapid diagnosis is crucial for the successful management of these infections disease. The conventional method need more time to detect the growth of bacterial. Alternatively, the bacteria are Pseudomonas aeruginosa and Shigella cultured on different media agar can be detected and classifies according to the volatile compound in shorter time using electronic nose (E-nose). Then, the data from electronic nose (E-nose) is processed using statistical method which is principal component analysis (PCA). The study shows the capability of electronic nose (E-nose) for early screening for bacterial infection in human stomach.
Fargnoli, Vanessa; Petignat, Patrick; Burton-Jeangros, Claudine
2015-01-01
Objectives Human papillomavirus self-sampling (self-HPV) is regarded as an alternative to Pap smear testing for women who do not participate in cervical cancer screening. This qualitative study aimed to determine women’s views on cervical cancer screening and the various obstacles to participation in screening, and to evaluate the perceived benefits and disadvantages of self-HPV. Method Twenty-four focus groups were conducted in 2012, with a total of 125 participants aged between 24 and 67 years. They were recruited through different channels, including flyers and posters, personal contacts, and an ongoing clinical trial focused on the unscreened population. Interview transcripts have been coded with the ATLAS.ti CAQDAS. Results Fifty-seven participants regularly attended screening and 68 had not been screened in the past 3 years. While some participants considered self-HPV as an acceptable screening method, others expressed concerns. Benefits included access, reduced costs, and time-saving. Disadvantages included the fear of not performing the test correctly, hurting oneself, and the accuracy of the test. Participants expressed concern that self-HPV would replace gynecological visits. Conclusion Self-HPV is not likely to rapidly or substantially modify women’s behaviors in regard to screening. While it may offer benefits in some specific situations, most women emphasized the advantages of regular gynecologist visits. PMID:26604830
Feng, Jingwen; Lin, Jie; Zhang, Pengquan; Yang, Songnan; Sa, Yu; Feng, Yuanming
2017-08-29
High-content screening is commonly used in studies of the DNA damage response. The double-strand break (DSB) is one of the most harmful types of DNA damage lesions. The conventional method used to quantify DSBs is γH2AX foci counting, which requires manual adjustment and preset parameters and is usually regarded as imprecise, time-consuming, poorly reproducible, and inaccurate. Therefore, a robust automatic alternative method is highly desired. In this manuscript, we present a new method for quantifying DSBs which involves automatic image cropping, automatic foci-segmentation and fluorescent intensity measurement. Furthermore, an additional function was added for standardizing the measurement of DSB response inhibition based on co-localization analysis. We tested the method with a well-known inhibitor of DSB response. The new method requires only one preset parameter, which effectively minimizes operator-dependent variations. Compared with conventional methods, the new method detected a higher percentage difference of foci formation between different cells, which can improve measurement accuracy. The effects of the inhibitor on DSB response were successfully quantified with the new method (p = 0.000). The advantages of this method in terms of reliability, automation and simplicity show its potential in quantitative fluorescence imaging studies and high-content screening for compounds and factors involved in DSB response.
The development of alternative methods for toxicity testing is driven by the need for scientifically valid data that can be obtained in a rapid and cost-efficient manner. In vitro systems provide a model in which chemical effects on cellular events can be examined using technique...
Strategic combinations and tiered application of alternative testing methods to replace or minimize the use of animal models is attracting much attention. With the advancement of high throughput screening (HTS) assays and legacy databases providing in vivo testing results, suffic...
Evaporation-Driven Bioassays in Suspended Droplets.
Hernandez-Perez, Ruth; Fan, Z Hugh; Garcia-Cordero, Jose L
2016-07-19
The microtiter plate has been an essential tool for diagnostics, high-throughput screening, and biological assays. We present an alternative platform to perform bioassays in a microplate format that exploits evaporation to drive assay reactions. Our method consists of droplets suspended on plastic pillars; reactions occur in these droplets instead of the wells. The pillars are fabricated by milling, and the rough surface created by this fabrication method pins the droplet to a constant contact line during the assay and also acts as a hydrophobic surface. Upon evaporation, natural convection arising from Marangoni currents mixes solutions in the droplet, which speeds up assay reactions, decreases assay times, and increases limits of detection. As a proof of concept we implemented two colorimetric assays to detect glucose and proteins in only 1.5 μL, without any external devices for mixing and with a digital microscope as a readout mechanism. Our platform is an ideal alternative to the microtiter plate, works with different volumes, is compatible with commercially available reagent dispensers and plate-readers, and could have broad applications in diagnostics and high-throughput screening.
Ye, Lidan; Yang, Chengcheng; Yu, Hongwei
2018-01-01
With increasing concerns in sustainable development, biocatalysis has been recognized as a competitive alternative to traditional chemical routes in the past decades. As nature's biocatalysts, enzymes are able to catalyze a broad range of chemical transformations, not only with mild reaction conditions but also with high activity and selectivity. However, the insufficient activity or enantioselectivity of natural enzymes toward non-natural substrates limits their industrial application, while directed evolution provides a potent solution to this problem, thanks to its independence on detailed knowledge about the relationship between sequence, structure, and mechanism/function of the enzymes. A proper high-throughput screening (HTS) method is the key to successful and efficient directed evolution. In recent years, huge varieties of HTS methods have been developed for rapid evaluation of mutant libraries, ranging from in vitro screening to in vivo selection, from indicator addition to multi-enzyme system construction, and from plate screening to computation- or machine-assisted screening. Recently, there is a tendency to integrate directed evolution with metabolic engineering in biosynthesis, using metabolites as HTS indicators, which implies that directed evolution has transformed from molecular engineering to process engineering. This paper aims to provide an overview of HTS methods categorized based on the reaction principles or types by summarizing related studies published in recent years including the work from our group, to discuss assay design strategies and typical examples of HTS methods, and to share our understanding on HTS method development for directed evolution of enzymes involved in specific catalytic reactions or metabolic pathways.
Minucci, Angelo; De Paolis, Elisa; Concolino, Paola; De Bonis, Maria; Rizza, Roberta; Canu, Giulia; Scaglione, Giovanni Luca; Mignone, Flavio; Scambia, Giovanni; Zuppi, Cecilia; Capoluongo, Ettore
2017-07-01
Evaluation of copy number variation (CNV) in BRCA1/2 genes, due to large genomic rearrangements (LGRs), is a mandatory analysis in hereditary breast and ovarian cancers families, if no pathogenic variants are found by sequencing. LGRs cannot be detected by conventional methods and several alternative methods have been developed. Since these approaches are expensive and time consuming, identification of alternative screening methods for LGRs detection is needed in order to reduce and optimize the diagnostic procedure. The aim of this study was to investigate a Competitive PCR-High Resolution Melting Analysis (C-PCR-HRMA) as molecular tool to detect recurrent BRCA1 LGRs. C-PCR-HRMA was performed on exons 3, 14, 18, 19, 20 and 21 of the BRCA1 gene; exons 4, 6 and 7 of the ALB gene were used as reference fragments. This study showed that it is possible to identify recurrent BRCA1 LGRs, by melting peak height ratio between target (BRCA1) and reference (ALB) fragments. Furthermore, we underline that a peculiar amplicon-melting profile is associated to a specific BRCA1 LGR. All C-PCR-HRMA results were confirmed by Multiplex ligation-dependent probe amplification. C-PCR-HRMA has proved to be an innovative, efficient and fast method for BRCA1 LGRs detection. Given the sensitivity, specificity and ease of use, c-PCR-HRMA can be considered an attractive and powerful alternative to other methods for BRCA1 CNVs screening, improving molecular strategies for BRCA testing in the context of Massive Parallel Sequencing. Copyright © 2017 Elsevier B.V. All rights reserved.
Sarangi, Laxmi Narayan; Naveena, Thodangala; Rana, Samir Kumar; Surendra, Kota Sri Naga Leela; Reddy, Rachamreddy Venkata Chandrasekhar; Bajibabu, Putla; Ponnanna, Nadikerianda Muthappa; Sharma, Girish Kumar; Srinivasan, Villuppanoor Alwar
2018-07-01
The extended frozen semen (EFS) batches produced from infectious bovine rhinotracheitis (IBR) sero-positive cattle and buffalo bulls housed in various semen stations in India are transported to the testing laboratory in liquid nitrogen (LN 2 ) for screening bovine herpesvirus-1 (BoHV-1). This procedure is laborious and poses LN 2 related hazards. An alternative logistics for transportation of samples was investigated. Use of Flinders Technology Associates (FTA ® ) elute card was evaluated for transportation of extended bovine semen to screen BoHV-1 DNA by real-time PCR targeting gB gene and the method was compared with the OIE approved Chelex resin based method. A protocol for extraction of BoHV-1 DNA from FTA ® card spotted with extended semen was optimized. The viral DNA was found to be stable on FTA ® card for at least 28 days when the cards are stored at 4°-37 °C. The analytical sensitivity for the assay was determined using variable dilutions of BoHV-1 spiked semen and positive plasmid harbouring gB gene (97bp) spotted onto FTA ® card and it was found to be 10 0.8 TCID 50 /ml or 100 copies respectively in real-time PCR. The test could detect as low as 10 0.008 TCID 50 /ml or 1 copy of positive plasmid when more number of replicates (n = 6) of the same sample were tested. This sensitivity was found to be comparable to Chelex method and both the methods demonstrated a very strong correlation (r = 0.9774; 95% CI: 0.9620-0.9860) in terms of Ct value (p < 0.0001). The diagnostic sensitivity and specificity of the FTA method in comparison to the Chelex method was 83.08% (95% CI: 71.73%-91.24%) and 93.23% (95% CI: 89.38%-96.01%) respectively when 316 samples were screened by both the methods. The degree of agreement between these two tests was good (Kappa value: 0.738; 95% CI: 0.646-0.829). The method was found to be robust and highly repeatable in inter-assay and intra-assay precision testing. The result suggests that the FTA ® card holds promise as an alternative system for transportation of EFS for downstream screening of BoHV-1 DNA. Copyright © 2018 Elsevier B.V. All rights reserved.
Reverté, Laia; Soliño, Lucía; Carnicer, Olga; Diogène, Jorge; Campàs, Mònica
2014-01-01
The emergence of marine toxins in water and seafood may have a considerable impact on public health. Although the tendency in Europe is to consolidate, when possible, official reference methods based on instrumental analysis, the development of alternative or complementary methods providing functional or toxicological information may provide advantages in terms of risk identification, but also low cost, simplicity, ease of use and high-throughput analysis. This article gives an overview of the immunoassays, cell-based assays, receptor-binding assays and biosensors that have been developed for the screening and quantification of emerging marine toxins: palytoxins, ciguatoxins, cyclic imines and tetrodotoxins. Their advantages and limitations are discussed, as well as their possible integration in research and monitoring programs. PMID:25431968
Use of the Analysis of the Volatile Faecal Metabolome in Screening for Colorectal Cancer
2015-01-01
Diagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples. Faecal samples were obtained from subjects who had a positive faecal occult blood sample (FOBT). Subjects subsequently had colonoscopies performed to classify them into low risk (non-cancer) and high risk (colorectal cancer) groups. Volatile organic compounds were analysed by selected ion flow tube mass spectrometry (SIFT-MS) and then data were analysed using both univariate and multivariate statistical methods. Ions most likely from hydrogen sulphide, dimethyl sulphide and dimethyl disulphide are statistically significantly higher in samples from high risk rather than low risk subjects. Results using multivariate methods show that the test gives a correct classification of 75% with 78% specificity and 72% sensitivity on FOBT positive samples, offering a potentially effective alternative to FOBT. PMID:26086914
A Method for Identifying Small-Molecule Aggregators Using Photonic Crystal Biosensor Microplates
Chan, Leo L.; Lidstone, Erich A.; Finch, Kristin E.; Heeres, James T.; Hergenrother, Paul J.; Cunningham, Brian T.
2010-01-01
Small molecules identified through high-throughput screens are an essential element in pharmaceutical discovery programs. It is now recognized that a substantial fraction of small molecules exhibit aggregating behavior leading to false positive results in many screening assays, typically due to nonspecific attachment to target proteins. Therefore, the ability to efficiently identify compounds within a screening library that aggregate can streamline the screening process by eliminating unsuitable molecules from further consideration. In this work, we show that photonic crystal (PC) optical biosensor microplate technology can be used to identify and quantify small-molecule aggregation. A group of aggregators and nonaggregators were tested using the PC technology, and measurements were compared with those gathered by three alternative methods: dynamic light scattering (DLS), an α-chymotrypsin colorimetric assay, and scanning electron microscopy (SEM). The PC biosensor measurements of aggregation were confirmed by visual observation using SEM, and were in general agreement with the α-chymotrypsin assay. DLS measurements, in contrast, demonstrated inconsistent readings for many compounds that are found to form aggregates in shapes, very different from the classical spherical particles assumed in DLS modeling. As a label-free detection method, the PC biosensor aggregation assay is simple to implement and provides a quantitative direct measurement of the mass density of material adsorbed to the transducer surface, whereas the microplate-based sensor format enables compatibility with high-throughput automated liquid-handling methods used in pharmaceutical screening. PMID:20930952
Enhanced HTS hit selection via a local hit rate analysis.
Posner, Bruce A; Xi, Hualin; Mills, James E J
2009-10-01
The postprocessing of high-throughput screening (HTS) results is complicated by the occurrence of false positives (inactive compounds misidentified as active by the primary screen) and false negatives (active compounds misidentified as inactive by the primary screen). An activity cutoff is frequently used to select "active" compounds from HTS data; however, this approach is insensitive to both false positives and false negatives. An alternative method that can minimize the occurrence of these artifacts will increase the efficiency of hit selection and therefore lead discovery. In this work, rather than merely using the activity of a given compound, we look at the presence and absence of activity among all compounds in its "chemical space neighborhood" to give a degree of confidence in its activity. We demonstrate that this local hit rate (LHR) analysis method outperforms hit selection based on ranking by primary screen activity values across ten diverse high throughput screens, spanning both cell-based and biochemical assay formats of varying biology and robustness. On average, the local hit rate analysis method was approximately 2.3-fold and approximately 1.3-fold more effective in identifying active compounds and active chemical series, respectively, than selection based on primary activity alone. Moreover, when applied to finding false negatives, this method was 2.3-fold better than ranking by primary activity alone. In most cases, novel hit series were identified that would have otherwise been missed. Additional uses of and observations regarding this HTS analysis approach are also discussed.
Rein, David B; Wittenborn, John S; Zhang, Xinzhi; Allaire, Benjamin A; Song, Michael S; Klein, Ronald; Saaddine, Jinan B
2011-01-01
Objective To determine whether biennial eye evaluation or telemedicine screening are cost-effective alternatives to current recommendations for the estimated 10 million people aged 30–84 with diabetes but no or minimal diabetic retinopathy. Data Sources United Kingdom Prospective Diabetes Study, National Health and Nutrition Examination Survey, American Academy of Ophthalmology Preferred Practice Patterns, Medicare Payment Schedule. Study Design Cost-effectiveness Monte Carlo simulation. Data Collection/Extraction Methods Literature review, analysis of existing surveys. Principal Findings Biennial eye evaluation was the most cost-effective treatment option when the ability to detect other eye conditions was included in the model. Telemedicine was most cost-effective when other eye conditions were not considered or when telemedicine was assumed to detect refractive error. The current annual eye evaluation recommendation was costly compared with either treatment alternative. Self-referral was most cost-effective up to a willingness to pay (WTP) of U.S.$37,600, with either biennial or annual evaluation most cost-effective at higher WTP levels. Conclusions Annual eye evaluations are costly and add little benefit compared with either plausible alternative. More research on the ability of telemedicine to detect other eye conditions is needed to determine whether it is more cost-effective than biennial eye evaluation. PMID:21492158
Gutner, Cassidy A; Pedersen, Eric R; Drummond, Sean P A
2018-05-01
Inclusion of consumer preferences to disseminate evidence-based psychosocial treatment (EBPT) is crucial to effectively bridge the science-to-practice quality chasm. We examined this treatment gap for insomnia, posttraumatic stress disorder (PTSD), depression, and comorbid symptoms in a sample of 622 young adult veterans through preference in symptom focus, treatment modality, and related gender differences among those screening positive for each problem. Data were collected from veteran drinkers recruited through targeted Facebook advertisements as part of a brief online alcohol intervention. Analyses demonstrated that veterans reported greater willingness to seek insomnia-focused treatment over PTSD- or depression-focused care. Notably, even when participants screened negative for insomnia, they preferred sleep-focused care to PTSD- or depression-focused care. Although one in five veterans with a positive screen would not consider care, veterans screening for both insomnia and PTSD who would consider care had a preference for in-person counseling, and those screening for both insomnia and depression had similar preferences for in-person and mobile app-based/computer self-help treatment. Marginal gender differences were found. Incorporating direct-to-consumer methods into research can help educate stakeholders about methods to expand EBPT access. Though traditional in-person counseling was often preferred, openness to app-based/computer interventions offers alternative methods to provide veterans with EBPTs. Published by Elsevier B.V.
Yarnoff, Benjamin O; Hoerger, Thomas J; Simpson, Siobhan K; Leib, Alyssa; Burrows, Nilka R; Shrestha, Sundar S; Pavkov, Meda E
2017-03-13
Better treatment during early stages of chronic kidney disease (CKD) may slow progression to end-stage renal disease and decrease associated complications and medical costs. Achieving early treatment of CKD is challenging, however, because a large fraction of persons with CKD are unaware of having this disease. Screening for CKD is one important method for increasing awareness. We examined the cost-effectiveness of identifying persons for early-stage CKD screening (i.e., screening for moderate albuminuria) using published CKD risk scores. We used the CKD Health Policy Model, a micro-simulation model, to simulate the cost-effectiveness of using CKD two published risk scores by Bang et al. and Kshirsagar et al. to identify persons in the US for CKD screening with testing for albuminuria. Alternative risk score thresholds were tested (0.20, 0.15, 0.10, 0.05, and 0.02) above which persons were assigned to receive screening at alternative intervals (1-, 2-, and 5-year) for follow-up screening if the first screening was negative. We examined incremental cost-effectiveness ratios (ICERs), incremental lifetime costs divided by incremental lifetime QALYs, relative to the next higher screening threshold to assess cost-effectiveness. Cost-effective scenarios were determined as those with ICERs less than $50,000 per QALY. Among the cost-effective scenarios, the optimal scenario was determined as the one that resulted in the highest lifetime QALYs. ICERs ranged from $8,823 per QALY to $124,626 per QALY for the Bang et al. risk score and $6,342 per QALY to $405,861 per QALY for the Kshirsagar et al. risk score. The Bang et al. risk score with a threshold of 0.02 and 2-year follow-up screening was found to be optimal because it had an ICER less than $50,000 per QALY and resulted in the highest lifetime QALYs. This study indicates that using these CKD risk scores may allow clinicians to cost-effectively identify a broader population for CKD screening with testing for albuminuria and potentially detect people with CKD at earlier stages of the disease than current approaches of screening only persons with diabetes or hypertension.
Interventions following hearing screening in adults: a systematic descriptive review.
Pronk, Marieke; Kramer, Sophia E; Davis, Adrian C; Stephens, Dafydd; Smith, Pauline A; Thodi, Chryssoula; Anteunis, Lucien J C; Parazzini, Marta; Grandori, Ferdinando
2011-09-01
Adult hearing screening may be a solution to the under-diagnosis and under-treatment of hearing loss in adults. Limited use and satisfaction with hearing aids indicate that consideration of alternative interventions following hearing screening may be needed. The primary aim of this study is to provide an overview of all intervention types that have been offered to adult (≥ 18 years) screen-failures. Systematic literature review. Articles were identified through systematic searches in PubMed, EMBASE, Cinahl, the Cochrane Library, private libraries, and through reference checking. Of the initial 3027 papers obtained from the searches, a total of 37 were found to be eligible. The great majority of the screening programmes (i.e. 26) referred screen-failures to a hearing specialist without further rehabilitation being specified. Most of the others (i.e. seven) led to the provision of hearing aids. Four studies offered alternative interventions comprising communication programme elements (e.g. speechreading, hearing tactics) or advice on environmental aids. Interventions following hearing screening generally comprised referral to a hearing specialist or hearing aid rehabilitation. Some programmes offered alternative rehabilitation options. These may be valuable as an addition to or replacement of hearing aid rehabilitation. It is recommended that this be addressed in future research.
Controversies in colorectal cancer screening.
Pox, Christian P
2014-01-01
Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.
An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.
ERIC Educational Resources Information Center
Square, Regina; And Others
1985-01-01
A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!
Reiman, Anne; Pandey, Sarojini; Lloyd, Kate L; Dyer, Nigel; Khan, Mike; Crockard, Martin; Latten, Mark J; Watson, Tracey L; Cree, Ian A; Grammatopoulos, Dimitris K
2016-11-01
Background Detection of disease-associated mutations in patients with familial hypercholesterolaemia is crucial for early interventions to reduce risk of cardiovascular disease. Screening for these mutations represents a methodological challenge since more than 1200 different causal mutations in the low-density lipoprotein receptor has been identified. A number of methodological approaches have been developed for screening by clinical diagnostic laboratories. Methods Using primers targeting, the low-density lipoprotein receptor, apolipoprotein B, and proprotein convertase subtilisin/kexin type 9, we developed a novel Ion Torrent-based targeted re-sequencing method. We validated this in a West Midlands-UK small cohort of 58 patients screened in parallel with other mutation-targeting methods, such as multiplex polymerase chain reaction (Elucigene FH20), oligonucleotide arrays (Randox familial hypercholesterolaemia array) or the Illumina next-generation sequencing platform. Results In this small cohort, the next-generation sequencing method achieved excellent analytical performance characteristics and showed 100% and 89% concordance with the Randox array and the Elucigene FH20 assay. Investigation of the discrepant results identified two cases of mutation misclassification of the Elucigene FH20 multiplex polymerase chain reaction assay. A number of novel mutations not previously reported were also identified by the next-generation sequencing method. Conclusions Ion Torrent-based next-generation sequencing can deliver a suitable alternative for the molecular investigation of familial hypercholesterolaemia patients, especially when comprehensive mutation screening for rare or unknown mutations is required.
Model dielectric function for 2D semiconductors including substrate screening
NASA Astrophysics Data System (ADS)
Trolle, Mads L.; Pedersen, Thomas G.; Véniard, Valerie
2017-01-01
Dielectric screening of excitons in 2D semiconductors is known to be a highly non-local effect, which in reciprocal space translates to a strong dependence on momentum transfer q. We present an analytical model dielectric function, including the full non-linear q-dependency, which may be used as an alternative to more numerically taxing ab initio screening functions. By verifying the good agreement between excitonic optical properties calculated using our model dielectric function, and those derived from ab initio methods, we demonstrate the versatility of this approach. Our test systems include: Monolayer hBN, monolayer MoS2, and the surface exciton of a 2 × 1 reconstructed Si(111) surface. Additionally, using our model, we easily take substrate screening effects into account. Hence, we include also a systematic study of the effects of substrate media on the excitonic optical properties of MoS2 and hBN.
Ritvo, Paul; Myers, Ronald E; Serenity, Mardie; Gupta, Samir; Inadomi, John M; Green, Beverly B; Jerant, Anthony; Tinmouth, Jill; Paszat, Lawrence; Pirbaglou, Meysam; Rabeneck, Linda
2017-08-01
To derive a taxonomy for colorectal cancer screening that advances Randomized Controlled Trials (RCTs) and screening uptake. Detailed publication review, multiple interviews with principal investigators (PIs) and collaboration with PIs as co-authors produced a CRCS intervention taxonomy. Semi-structured interview questions with PIs (Drs. Inadomi, Myers, Green, Gupta, Jerant and Ritvo) yielded details about trial conduct. Interview comparisons led to an iterative process informing serial interviews until a consensus was obtained on final taxonomy structure. These taxonomy headings (Engagement Sponsor, Population Targeted, Alternative Screening Tests, Delivery Methods, and Support for Test Performance (EPADS)) were used to compare studies. Exemplary insights emphasized: 1) direct test delivery to patients; 2) linguistic-ethnic matching of staff to minority subjects; and 3) authorization of navigators to schedule or refer for colonoscopies and/or distribute stool blood tests during screening promotion. PIs of key RCTs (2012-2015) derived a CRCS taxonomy useful in detailed examination of CRCS promotion and design of future RCTs. Copyright © 2017 Elsevier Inc. All rights reserved.
The report gives results of a screening evaluation of volatile organic emissions from printed circuit board laminates and potential pollution prevention alternatives. In the evaluation, printed circuit board laminates, without circuitry, commonly found in personal computer (PC) m...
Bell, Andrew S; Bradley, Joseph; Everett, Jeremy R; Loesel, Jens; McLoughlin, David; Mills, James; Peakman, Marie-Claire; Sharp, Robert E; Williams, Christine; Zhu, Hongyao
2016-11-01
High-throughput screening (HTS) is an effective method for lead and probe discovery that is widely used in industry and academia to identify novel chemical matter and to initiate the drug discovery process. However, HTS can be time consuming and costly and the use of subsets as an efficient alternative to screening entire compound collections has been investigated. Subsets may be selected on the basis of chemical diversity, molecular properties, biological activity diversity or biological target focus. Previously, we described a novel form of subset screening: plate-based diversity subset (PBDS) screening, in which the screening subset is constructed by plate selection (rather than individual compound cherry-picking), using algorithms that select for compound quality and chemical diversity on a plate basis. In this paper, we describe a second-generation approach to the construction of an updated subset: PBDS2, using both plate and individual compound selection, that has an improved coverage of the chemical space of the screening file, whilst only selecting the same number of plates for screening. We describe the validation of PBDS2 and its successful use in hit and lead discovery. PBDS2 screening became the default mode of singleton (one compound per well) HTS for lead discovery in Pfizer.
Recent trends in digital halftoning
NASA Astrophysics Data System (ADS)
Delabastita, Paul A.
1997-02-01
Screening is perhaps the oldest form of image processing. The word refers to the mechanical cross line screens that were used at the beginning of this century for the purpose of photomechanical reproduction. Later on, these mechanical screens were replaced by photographic contact screens that enabled significantly improved process control. In the early eighties, the optical screening on graphic arts scanners was replaced by a combination of laser optics and electronic screening. The algorithms, however, were still digital implementations of the original optical methods. The printing needs in the fast growing computer and software industry gave birth to a number of alternative printing technologies such as electrophotographic and inkjet printing. Originally these deices were only designed for printing text, but soon people started experimenting and using them for printing images. The relatively low spatial resolutions of these new devices however made complete review of 'the screening issue' necessary to achieve an acceptable image quality. In this paper a number of recent developments in screening technology are summarized. Special attention is given to the interaction that exists between a halftone screen and the printing devices on which they are rendered including the color mixing behavior. Improved screening techniques are presented that take advantage of modeling the physical behavior of the rendering device.
Tang, F; Xiong, Y; Zhang, H; Wu, K; Xiang, Y; Shao, J-B; Ai, H-W; Xiang, Y-P; Zheng, X-L; Lv, J-R; Sun, H; Bao, L-S; Zhang, Z; Hu, H-B; Zhang, J-Y; Chen, L; Lu, J; Liu, W-Y; Mei, H; Ma, Y; Xu, C-F; Fang, A-Y; Gu, M; Xu, C-Y; Chen, Y; Chen, Z; Sun, Z-Y
2016-03-01
To detect Salmonella more efficiently and isolate strains more easily, a novel and simple detection method that uses an enrichment assay and two chromogenic reactions on a chromatography membrane was developed. Grade 3 chromatography paper is used as functionalized solid phase support (SPS), which contains specially optimized medium. One reaction for screening is based on the sulfate-reducing capacity of Salmonella. Hydrogen sulfide (H2S) generated by Salmonella reacts with ammonium ferric citrate to produce black colored ferrous sulfide. Another reaction is based on Salmonella C8 esterase that is unique for Enterobacteriaceae except Serratia and interacts with 4-methylumbelliferyl caprylate (MUCAP) to produce fluorescent umbelliferone, which is visible under ultraviolet light. A very low detection limit (10(1) CFU ml(-1)) for Salmonella was achieved on the background of 10(5) CFU ml(-1) Escherichia coli. More importantly, testing with more than 1,000 anal samples indicated that our method has a high positive detection rate and is relatively low cost, compared with the traditional culture-based method. It took only 1 day for the preliminary screening and 2 days to efficiently isolate the Salmonella cells, indicating that the new assay is specific, rapid, and simple for Salmonella detection. In contrast to the traditional culture-based method, this method can be easily used to screen and isolate targeted strains with the naked eye. The results of quantitative and comparative experiments showed that the visual detection technique is an efficient alternative method for the screening of Salmonella spp. in many applications of large-sized samples related to public health surveillance.
NASA Astrophysics Data System (ADS)
Nieuwoudt, Michel K.; Holroyd, Steve E.; McGoverin, Cushla M.; Simpson, M. Cather; Williams, David E.
2017-02-01
Point-of-care diagnostics are of interest in the medical, security and food industry, the latter particularly for screening food adulterated for economic gain. Milk adulteration continues to be a major problem worldwide and different methods to detect fraudulent additives have been investigated for over a century. Laboratory based methods are limited in their application to point-of-collection diagnosis and also require expensive instrumentation, chemicals and skilled technicians. This has encouraged exploration of spectroscopic methods as more rapid and inexpensive alternatives. Raman spectroscopy has excellent potential for screening of milk because of the rich complexity inherent in its signals. The rapid advances in photonic technologies and fabrication methods are enabling increasingly sensitive portable mini-Raman systems to be placed on the market that are both affordable and feasible for both point-of-care and point-of-collection applications. We have developed a powerful spectroscopic method for rapidly screening liquid milk for sucrose and four nitrogen-rich adulterants (dicyandiamide (DCD), ammonium sulphate, melamine, urea), using a combined system: a small, portable Raman spectrometer with focusing fibre optic probe and optimized reflective focusing wells, simply fabricated in aluminium. The reliable sample presentation of this system enabled high reproducibility of 8% RSD (residual standard deviation) within four minutes. Limit of detection intervals for PLS calibrations ranged between 140 - 520 ppm for the four N-rich compounds and between 0.7 - 3.6 % for sucrose. The portability of the system and reliability and reproducibility of this technique opens opportunities for general, reagentless adulteration screening of biological fluids as well as milk, at point-of-collection.
PERFORMANCE DEMONSTRATIONS OF ALTERNATIVE SCREEN RECLAMATION PRODUCTS FOR SCREEN PRINTING
This project evaluated environmentally-preferable products for the screen reclamation process In screen printing during month-long demonstrations at 23 printing facilities nationwide. hrough the Environmental Protection Agency (EPA) Design for the Environment Printing Project, pr...
Secrets of the Chinese magic mirror replica
NASA Astrophysics Data System (ADS)
Mak, Se-yuen; Yip, Din-yan
2001-03-01
We examine the structure of five Chinese magic mirror replicas using a special imaging technique developed by the authors. All mirrors are found to have a two-layered structure. The reflecting surface that gives rise to a projected magic pattern on the screen is hidden under a polished half-reflecting top layer. An alternative method of making the magic mirror using ancient technology has been proposed. Finally, we suggest a simple method of reconstructing a mirror replica in the laboratory.
de Almeida, Sergio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea Elisa; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K.; Ellis, Ronald J.
2016-01-01
Objectives The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia (HAD), but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. Methods 108 participants (including 60 HIV-infected persons), completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible three-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Results Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75% respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared to the gold standard NP battery, were Trail Making Test A, WAIS-III Digit Symbol (DS) and HVLT-R Total Recall (sensitivity 91%, specificity 96%), and DS, BVMT-R Total Recall and Grooved Pegboard Test-Dominant Hand (sensitivity 94%, specificity 91%). Conclusions Both test combinations can be administered in under 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination. PMID:27828876
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2018-01-01
This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Fabrication of a wettability-gradient surface on copper by screen-printing techniques
NASA Astrophysics Data System (ADS)
Huang, Ding-Jun; Leu, Tzong-Shyng
2015-08-01
In this study, a screen-printing technique is utilized to fabricate a wettability-gradient surface on a copper substrate. The pattern definitions on the copper surface were freely fabricated to define the regions with different wettabilities, for which the printing definition technique was developed as an alternative to the existing costly photolithography techniques. This fabrication process using screen printing in tandem with chemical modification methods can easily realize an excellent wettability-gradient surface with superhydrophobicity and superhydrophilicity. Surface analyses were performed to characterize conditions in some fabrication steps. A water droplet movement sequence is provided to clearly demonstrate the droplet-driving effectiveness of the fabricated gradient surface. The droplet-driving efficiency offers a promising solution for condensation heat transfer applications in the foreseeable future.
Weidel, Elisabeth; Negri, Matthias; Empting, Martin; Hinsberger, Stefan; Hartmann, Rolf W
2014-01-01
In order to identify new scaffolds for drug discovery, surface plasmon resonance is frequently used to screen structurally diverse libraries. Usually, hit rates are low and identification processes are time consuming. Hence, approaches which improve hit rates and, thus, reduce the library size are required. In this work, we studied three often used strategies for their applicability to identify inhibitors of PqsD. In two of them, target-specific aspects like inhibition of a homologous protein or predicted binding determined by virtual screening were used for compound preselection. Finally, a fragment library, covering a large chemical space, was screened and served as comparison. Indeed, higher hit rates were observed for methods employing preselected libraries indicating that target-oriented compound selection provides a time-effective alternative.
Flumignan, Danilo Luiz; Boralle, Nivaldo; Oliveira, José Eduardo de
2010-06-30
In this work, the combination of carbon nuclear magnetic resonance ((13)C NMR) fingerprinting with pattern-recognition analyses provides an original and alternative approach to screening commercial gasoline quality. Soft Independent Modelling of Class Analogy (SIMCA) was performed on spectroscopic fingerprints to classify representative commercial gasoline samples, which were selected by Hierarchical Cluster Analyses (HCA) over several months in retails services of gas stations, into previously quality-defined classes. Following optimized (13)C NMR-SIMCA algorithm, sensitivity values were obtained in the training set (99.0%), with leave-one-out cross-validation, and external prediction set (92.0%). Governmental laboratories could employ this method as a rapid screening analysis to discourage adulteration practices. Copyright 2010 Elsevier B.V. All rights reserved.
Houzet, Laurent; Deleage, Claire; Satie, Anne-Pascale; Merlande, Laetitia; Mahe, Dominique; Dejucq-Rainsford, Nathalie
2015-01-01
PCR is the most widely applied technique for large scale screening of bacterial clones, mouse genotypes, virus genomes etc. A drawback of large PCR screening is that amplicon analysis is usually performed using gel electrophoresis, a step that is very labor intensive, tedious and chemical waste generating. Single genome amplification (SGA) is used to characterize the diversity and evolutionary dynamics of virus populations within infected hosts. SGA is based on the isolation of single template molecule using limiting dilution followed by nested PCR amplification and requires the analysis of hundreds of reactions per sample, making large scale SGA studies very challenging. Here we present a novel approach entitled Long Amplicon Melt Profiling (LAMP) based on the analysis of the melting profile of the PCR reactions using SYBR Green and/or EvaGreen fluorescent dyes. The LAMP method represents an attractive alternative to gel electrophoresis and enables the quick discrimination of positive reactions. We validate LAMP for SIV and HIV env-SGA, in 96- and 384-well plate formats. Because the melt profiling allows the screening of several thousands of PCR reactions in a cost-effective, rapid and robust way, we believe it will greatly facilitate any large scale PCR screening. PMID:26053379
Stals, M; Verhoeven, S; Bruggeman, M; Pellens, V; Schroeyers, W; Schreurs, S
2014-01-01
The Euratom BSS requires that in the near future (2015) the building materials for application in dwellings or buildings such as offices or workshops are screened for NORM nuclides. The screening tool is the activity concentration index (ACI). Therefore it is expected that a large number of building materials will be screened for NORM and thus require ACI determination. Nowadays, the proposed standard for determination of building material ACI is a laboratory analyses technique with high purity germanium spectrometry and 21 days equilibrium delay. In this paper, the B-NORM method for determination of building material ACI is assessed as a faster method that can be performed on-site, alternative to the aforementioned standard method. The B-NORM method utilizes a LaBr3(Ce) scintillation probe to obtain the spectral data. Commercially available software was applied to comprehensively take into account the factors determining the counting efficiency. The ACI was determined by interpreting the gamma spectrum from (226)Ra and its progeny; (232)Th progeny and (40)K. In order to assess the accuracy of the B-NORM method, a large selection of samples was analyzed by a certified laboratory and the results were compared with the B-NORM results. The results obtained with the B-NORM method were in good correlation with the results obtained by the certified laboratory, indicating that the B-NORM method is an appropriate screening method to assess building material ACI. The B-NORM method was applied to analyze more than 120 building materials on the Belgian market. No building materials that exceed the proposed reference level of 1 mSv/year were encountered. Copyright © 2013 Elsevier Ltd. All rights reserved.
Jumhawan, Udi; Putri, Sastia Prama; Yusianto; Bamba, Takeshi; Fukusaki, Eiichiro
2015-11-01
Development of authenticity screening for Asian palm civet coffee, the world-renowned priciest coffee, was previously reported using metabolite profiling through gas chromatography/mass spectrometry (GC/MS). However, a major drawback of this approach is the high cost of the instrument and maintenance. Therefore, an alternative method is needed for quality and authenticity evaluation of civet coffee. A rapid, reliable and cost-effective analysis employing a universal detector, GC coupled with flame ionization detector (FID), and metabolite fingerprinting has been established for discrimination analysis of 37 commercial and non-commercial coffee beans extracts. gas chromatography/flame ionization detector (GC/FID) provided higher sensitivity over a similar range of detected compounds than GC/MS. In combination with multivariate analysis, GC/FID could successfully reproduce quality prediction from GC/MS for differentiation of commercial civet coffee, regular coffee and coffee blend with 50 wt % civet coffee content without prior metabolite details. Our study demonstrated that GC/FID-based metabolite fingerprinting can be effectively actualized as an alternative method for coffee authenticity screening in industries. Copyright © 2015. Published by Elsevier B.V.
Cervical Cancer Screening with AMIGAS
Lairson, David R.; Chang, Yu-Chia; Byrd, Theresa L.; Smith, Judith Lee; Fernandez, Maria E.; Wilson, Katherine M.
2015-01-01
Background Hispanic women have a higher incidence of cervical cancer than all other races and ethnicities. In Hispanic subgroups, Mexican American women were among the least likely to have received cervical cancer screening. In a recent RCT, Ayudando a las Mujeres con Información, Guia, y Amor para su Salud (AMIGAS) was shown to increase cervical cancer screening rates among women of Mexican descent at 6 months in all intervention arms compared to the control arm. Limited information exists about the economics of interventions to increase cervical cancer screening rates among women of Mexican descent. Purpose This study aims to estimate the cost-effectiveness of the alternative AMIGAS intervention methods for increasing cervical cancer screening among low-income women of Mexican descent in three U.S. communities. Methods Cost data were collected from 2008 to 2011 alongside the AMIGAS study of 613 women. Receipt of Pap test within 6 months of intervention was the primary outcome measure in the cost-effectiveness analysis, conducted during 2012–2013. Results The cost per additional woman screened comparing the video-only intervention to usual care was $980. The cost increased to $1,309 with participant time cost included. With an additional cost per participant of $3.90 compared to flipchart only, the full AMIGAS program (video plus flipchart) yielded 6.8% additional women screened. Conclusions Results on the average and incremental cost-effectiveness of the AMIGAS program elements may assist health policymakers and program managers to select and appropriately budget for interventions shown to increase cervical cancer screening among low-income women of Mexican descent. PMID:24842738
NASA Astrophysics Data System (ADS)
Zannah, Fathul; Amin, Mohammad; Suwono, Hadi; Lukiati, Betty
2017-05-01
Diplazium esculentum is one of the ferns used by the Dayak's people in Central Kalimantan as a traditional medicine to treat tumors, asthma, and acne. This study aims to determine the content of bioactive compounds in Diplazium esculentum in Central Kalimantan. This research is a descriptive study with a qualitative approach. Qualitative phytochemical screening detected the presence of flavonoids, polyphenols, alkaloids, terpenoids and saponins in aqueous extracts with the boiled and brewed method, while in ethanol extract this detected polyphenols, alkaloids, terpenoids, and saponins. The results show that the use of water as a solvent can be an alternative in plant extracts.
Vahabi, Mandana; Lofters, Aisha
2016-08-24
Canada has observed significant decreases in incidence and mortality of cervical cancer in recent decades, and this has been attributed to appropriate screening (i.e., the Pap test). However, certain subgroups including Muslim immigrants show higher rates of cervical cancer mortality despite their lower incidence. Low levels of screening have been attributed to such barriers as lack of a family physician, inconvenient clinic hours, having a male physician, and cultural barriers (e.g., modesty, language). HPV self -sampling helps to alleviate many of these barriers. However, little is known about the acceptability of this evidence-based strategy among Muslim women. This study explored Muslim immigrant women's views on cervical cancer screening and the acceptability of HPV self-sampling. An exploratory community-based mixed methods design was used. A convenience sample of 30 women was recruited over a 3-month period (June-August 2015) in the Greater Toronto Area. All were between 21 and 69 years old, foreign-born, self-identified as Muslim, and had good knowledge of English. Data were collected through focus groups. This study provides critical insights about the importance of religious and cultural beliefs in shaping the daily and health care experiences of Muslim women and their cancer screening decisions. Our study showed the deterring impact of beliefs and health practices in home countries on Muslim immigrant women's utilization of screening services. Limited knowledge about cervical cancer and screening guidelines and need for provision of culturally appropriate sexual health information were emphasized. The results revealed that HPV self-sampling provides a favorable alternative model of care to the traditional provider-administered Pap testing for this population. To enhance Muslim immigrant women screening uptake, efforts should made to increase 1) their knowledge of the Canadian health care system and preventive services at the time of entry to Canada, and 2) access to culturally sensitive education programs, female health professionals, and alternative modes of screening like HPV self-sampling. Health professionals need to take an active role in offering screening during health encounters, be educated about sexual health communication with minority women, and be aware of the detrimental impact of preconceived assumptions about sexual activity of Muslim women.
Feldman, Joshua; Davie, Sam; Kiran, Tara
2017-01-01
Our Family Health Team is located in Toronto, Canada and provides care to over 35 000 patients. Like many practices in Canada, we took an opportunistic approach to cervical, breast, and colorectal cancer screening. We wanted to shift to a proactive, population-based approach but were unable to systematically identify patients overdue for screening or calculate baseline screening rates. Our initiative had two goals: (1) to develop a method for systematically identifying patients eligible for screening and whether they were overdue and (2) to increase screening rates for cervical, breast, and colorectal cancer. Using external government data in combination with our practice's electronic medical record, we developed a process to identify patients eligible and overdue for cancer screening. After generating baseline data, we implemented an evidence-based, multifaceted intervention to improve cancer screening rates. We sent a personalized reminder letter to overdue patients, provided physicians with practice-level audit and feedback, and improved our electronic reminder function by updating charts with accurate data on the Fecal Occult Blood Test (FOBT). Following our initial intervention, we sought to maintain and further improve our screening rates by experimenting with alternative recall methods and collecting patient feedback. Screening rates significantly improved for all three cancers. Between March 2014 and December 2016, the cervical cancer screening rate increased from 60% to 71% (p<0.05), the breast cancer screening rate increased from 56% to 65% (p<0.05), and the overall colorectal screening rate increased from 59% to 70% (p<0.05). The increase in colorectal screening rates was largely due to an increase in FOBT screening from 18% to 25%, while colonoscopy screening remained relatively unchanged, shifting from 45% to 46%. We also found that patients living in low income neighbourhoods were less likely to be screened. Following our intervention, this equity gap narrowed modestly for breast and colorectal cancer but did not change for cervical cancer screening. Our future improvement efforts will be focused on reducing the gap in screening between patients living in low-income and high-income neighbourhoods while maintaining overall gains.
Odoardi, Sara; Fisichella, Marco; Romolo, Francesco Saverio; Strano-Rossi, Sabina
2015-09-01
The increasing number of new psychoactive substances (NPS) present in the illicit market render their identification in biological fluids/tissues of great concern for clinical and forensic toxicology. Analytical methods able to detect the huge number of substances that can be used are sought, considering also that many NPS are not detected by the standard immunoassays generally used for routine drug screening. The aim of this work was to develop a method for the screening of different classes of NPS (a total of 78 analytes including cathinones, synthetic cannabinoids, phenethylamines, piperazines, ketamine and analogues, benzofurans, tryptamines) from blood samples. The simultaneous extraction of analytes was performed by Dispersive Liquid/Liquid Microextraction DLLME, a very rapid, cheap and efficient extraction technique that employs microliters amounts of organic solvents. Analyses were performed by a target Ultrahigh Performance Liquid Chromatography tandem Mass Spectrometry (UHPLC-MS/MS) method in multiple reaction monitoring (MRM). The method allowed the detection of the studied analytes with limits of detection (LODs) ranging from 0.2 to 2ng/mL. The proposed DLLME method can be used as an alternative to classical liquid/liquid or solid-phase extraction techniques due to its rapidity, necessity to use only microliters amounts of organic solvents, cheapness, and to its ability to extract simultaneously a huge number of analytes also from different chemical classes. The method was then applied to 60 authentic real samples from forensic cases, demonstrating its suitability for the screening of a wide number of NPS. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of three noninvasive methods for hemoglobin screening of blood donors.
Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S
2015-02-01
To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.
Lei, Qiong; Ba, Sai; Zhang, Hao; Wei, Yanyan; Lee, Jasmine Yiqin; Li, Tianhu
2016-05-15
Enrichment of omega-3 fatty acids in cod liver oil via alternate operation of solvent winterization and enzymatic interesterification was attempted. Variables including separation method, solvent, oil concentration, time and temperature were optimized for the winterization. Meanwhile, Novozyme 435, Lipozyme RM IM and Lipozyme TL IM were screened for interesterification efficiency under different system air condition, time and temperature. In optimized method, alternate winterization (0.1g/mL oil/acetone, 24h, -80°C, precooled Büchner filtration) and interesterification (Lipozyme TL IM, N2 flow, 2.5h, 40°C) successfully doubled the omega-3 fatty acid content to 43.20 mol%. (1)H NMR was used to determine omega-3 fatty acid content, and GC-MS to characterize oil product, which mainly contained DHA (15.81 mol%) and EPA (20.23 mol%). The proposed method offers considerable efficiency and reduce production cost drastically. Oil produced thereof is with high quality and of particular importance for the development of omega-3 based active pharmaceutical ingredients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Thinking Style as a Predictor of Men’s Participation in Cancer Screening
McGuiness, Clare E.; Turnbull, Deborah; Wilson, Carlene; Duncan, Amy; Flight, Ingrid H.; Zajac, Ian
2016-01-01
Men’s participation in cancer screening may be influenced by their thinking style. Men’s need for cognition (NFC) and faith in intuition were measured to explore whether they varied by demographic variables or predicted screening behavior. Australian males (n = 585, aged 50-74 years) completed surveys about past screening and were subsequently offered mailed fecal occult blood tests (FOBTs). Demographic predictors included age, socioeconomic status, educational attainment, and language spoken at home. The screening behaviors were self-reported prostate cancer screening (prostate-specific antigen testing and digital rectal examinations [DREs]), and colorectal cancer screening (self-reported FOBT participation and recorded uptake of the FOBT offer). Analysis comprised principal component analysis and structural equation modelling. NFC was positively related to demographic variables education, socioeconomic status, and speaking English at home. Faith in intuition was negatively related to educational attainment. NFC predicted variance in self-reported DRE participation (r = .11, p = .016). No other relationships with thinking style were statistically significant. The relationship of NFC to DRE participation may reflect the way certain attributes of this screening method are processed, or alternatively, it may reflect willingness to report participation. The relationship of thinking style to a range of healthy behaviors should be further explored. PMID:27923966
Molecular toolbox for the identification of unknown genetically modified organisms.
Ruttink, Tom; Demeyer, Rolinde; Van Gulck, Elke; Van Droogenbroeck, Bart; Querci, Maddalena; Taverniers, Isabel; De Loose, Marc
2010-03-01
Competent laboratories monitor genetically modified organisms (GMOs) and products derived thereof in the food and feed chain in the framework of labeling and traceability legislation. In addition, screening is performed to detect the unauthorized presence of GMOs including asynchronously authorized GMOs or GMOs that are not officially registered for commercialization (unknown GMOs). Currently, unauthorized or unknown events are detected by screening blind samples for commonly used transgenic elements, such as p35S or t-nos. If (1) positive detection of such screening elements shows the presence of transgenic material and (2) all known GMOs are tested by event-specific methods but are not detected, then the presence of an unknown GMO is inferred. However, such evidence is indirect because it is based on negative observations and inconclusive because the procedure does not identify the causative event per se. In addition, detection of unknown events is hampered in products that also contain known authorized events. Here, we outline alternative approaches for analytical detection and GMO identification and develop new methods to complement the existing routine screening procedure. We developed a fluorescent anchor-polymerase chain reaction (PCR) method for the identification of the sequences flanking the p35S and t-nos screening elements. Thus, anchor-PCR fingerprinting allows the detection of unique discriminative signals per event. In addition, we established a collection of in silico calculated fingerprints of known events to support interpretation of experimentally generated anchor-PCR GM fingerprints of blind samples. Here, we first describe the molecular characterization of a novel GMO, which expresses recombinant human intrinsic factor in Arabidopsis thaliana. Next, we purposefully treated the novel GMO as a blind sample to simulate how the new methods lead to the molecular identification of a novel unknown event without prior knowledge of its transgene sequence. The results demonstrate that the new methods complement routine screening procedures by providing direct conclusive evidence and may also be useful to resolve masking of unknown events by known events.
Nair, Vijay; Strecher, Victor; Fagerlin, Angela; Ubel, Peter; Resnicow, Kenneth; Murphy, Susan; Little, Roderick; Chakraborty, Bibhas; Zhang, Aijun
2008-01-01
Health behavior intervention studies have focused primarily on comparing new programs and existing programs via randomized controlled trials. However, numbers of possible components (factors) are increasing dramatically as a result of developments in science and technology (e.g., Web-based surveys). These changes dictate the need for alternative methods that can screen and quickly identify a large set of potentially important treatment components. We have developed and implemented a multiphase experimentation strategy for accomplishing this goal. We describe the screening phase of this strategy and the use of fractional factorial designs (FFDs) in studying several components economically. We then use 2 ongoing behavioral intervention projects to illustrate the usefulness of FFDs. FFDs should be supplemented with follow-up experiments in the refining phase so any critical assumptions about interactions can be verified. PMID:18556602
Procedures for central auditory processing screening in schoolchildren.
Carvalho, Nádia Giulian de; Ubiali, Thalita; Amaral, Maria Isabel Ramos do; Santos, Maria Francisca Colella
2018-03-22
Central auditory processing screening in schoolchildren has led to debates in literature, both regarding the protocol to be used and the importance of actions aimed at prevention and promotion of auditory health. Defining effective screening procedures for central auditory processing is a challenge in Audiology. This study aimed to analyze the scientific research on central auditory processing screening and discuss the effectiveness of the procedures utilized. A search was performed in the SciELO and PUBMed databases by two researchers. The descriptors used in Portuguese and English were: auditory processing, screening, hearing, auditory perception, children, auditory tests and their respective terms in Portuguese. original articles involving schoolchildren, auditory screening of central auditory skills and articles in Portuguese or English. studies with adult and/or neonatal populations, peripheral auditory screening only, and duplicate articles. After applying the described criteria, 11 articles were included. At the international level, central auditory processing screening methods used were: screening test for auditory processing disorder and its revised version, screening test for auditory processing, scale of auditory behaviors, children's auditory performance scale and Feather Squadron. In the Brazilian scenario, the procedures used were the simplified auditory processing assessment and Zaidan's battery of tests. At the international level, the screening test for auditory processing and Feather Squadron batteries stand out as the most comprehensive evaluation of hearing skills. At the national level, there is a paucity of studies that use methods evaluating more than four skills, and are normalized by age group. The use of simplified auditory processing assessment and questionnaires can be complementary in the search for an easy access and low-cost alternative in the auditory screening of Brazilian schoolchildren. Interactive tools should be proposed, that allow the selection of as many hearing skills as possible, validated by comparison with the battery of tests used in the diagnosis. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Discovery of Cationic Polymers for Non-viral Gene Delivery using Combinatorial Approaches
Barua, Sutapa; Ramos, James; Potta, Thrimoorthy; Taylor, David; Huang, Huang-Chiao; Montanez, Gabriela; Rege, Kaushal
2015-01-01
Gene therapy is an attractive treatment option for diseases of genetic origin, including several cancers and cardiovascular diseases. While viruses are effective vectors for delivering exogenous genes to cells, concerns related to insertional mutagenesis, immunogenicity, lack of tropism, decay and high production costs necessitate the discovery of non-viral methods. Significant efforts have been focused on cationic polymers as non-viral alternatives for gene delivery. Recent studies have employed combinatorial syntheses and parallel screening methods for enhancing the efficacy of gene delivery, biocompatibility of the delivery vehicle, and overcoming cellular level barriers as they relate to polymer-mediated transgene uptake, transport, transcription, and expression. This review summarizes and discusses recent advances in combinatorial syntheses and parallel screening of cationic polymer libraries for the discovery of efficient and safe gene delivery systems. PMID:21843141
NASA Astrophysics Data System (ADS)
Lau, Wan F.; Withka, Jane M.; Hepworth, David; Magee, Thomas V.; Du, Yuhua J.; Bakken, Gregory A.; Miller, Michael D.; Hendsch, Zachary S.; Thanabal, Venkataraman; Kolodziej, Steve A.; Xing, Li; Hu, Qiyue; Narasimhan, Lakshmi S.; Love, Robert; Charlton, Maura E.; Hughes, Samantha; van Hoorn, Willem P.; Mills, James E.
2011-07-01
Fragment Based Drug Discovery (FBDD) continues to advance as an efficient and alternative screening paradigm for the identification and optimization of novel chemical matter. To enable FBDD across a wide range of pharmaceutical targets, a fragment screening library is required to be chemically diverse and synthetically expandable to enable critical decision making for chemical follow-up and assessing new target druggability. In this manuscript, the Pfizer fragment library design strategy which utilized multiple and orthogonal metrics to incorporate structure, pharmacophore and pharmacological space diversity is described. Appropriate measures of molecular complexity were also employed to maximize the probability of detection of fragment hits using a variety of biophysical and biochemical screening methods. In addition, structural integrity, purity, solubility, fragment and analog availability as well as cost were important considerations in the selection process. Preliminary analysis of primary screening results for 13 targets using NMR Saturation Transfer Difference (STD) indicates the identification of uM-mM hits and the uniqueness of hits at weak binding affinities for these targets.
Lau, Wan F; Withka, Jane M; Hepworth, David; Magee, Thomas V; Du, Yuhua J; Bakken, Gregory A; Miller, Michael D; Hendsch, Zachary S; Thanabal, Venkataraman; Kolodziej, Steve A; Xing, Li; Hu, Qiyue; Narasimhan, Lakshmi S; Love, Robert; Charlton, Maura E; Hughes, Samantha; van Hoorn, Willem P; Mills, James E
2011-07-01
Fragment Based Drug Discovery (FBDD) continues to advance as an efficient and alternative screening paradigm for the identification and optimization of novel chemical matter. To enable FBDD across a wide range of pharmaceutical targets, a fragment screening library is required to be chemically diverse and synthetically expandable to enable critical decision making for chemical follow-up and assessing new target druggability. In this manuscript, the Pfizer fragment library design strategy which utilized multiple and orthogonal metrics to incorporate structure, pharmacophore and pharmacological space diversity is described. Appropriate measures of molecular complexity were also employed to maximize the probability of detection of fragment hits using a variety of biophysical and biochemical screening methods. In addition, structural integrity, purity, solubility, fragment and analog availability as well as cost were important considerations in the selection process. Preliminary analysis of primary screening results for 13 targets using NMR Saturation Transfer Difference (STD) indicates the identification of uM-mM hits and the uniqueness of hits at weak binding affinities for these targets.
Sarkar, Kuhu; Braden, Erik V; Bonke, Shannon A; Bach, Udo; Müller-Buschbaum, Peter
2015-08-24
Diblock copolymers have been used in sol-gel synthesis to successfully tailor the nanoscale morphology of thin ZnO films. As the fabrication of several-micron-thick mesoporous films such as those required in dye-sensitized solar cells (DSSCs) was difficult with this approach, we exploited the benefits of diblock-copolymer-directed synthesis that made it compatible with screen printing. The simple conversion of the diblock copolymer ZnO precursor sol to a screen-printing paste was not possible as it resulted in poor film properties. To overcome this problem, an alternative route is proposed in which the diblock copolymer ZnO precursor sol is first blade coated and calcined, then converted to a screen-printing paste. This allows the benefits of diblock-copolymer-directed particle formation to be compatible with printing methods. The morphologies of the ZnO nanostructures were studied by SEM and correlated with the current density-voltage characteristics. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
CHAM: a fast algorithm of modelling non-linear matter power spectrum in the sCreened HAlo Model
NASA Astrophysics Data System (ADS)
Hu, Bin; Liu, Xue-Wen; Cai, Rong-Gen
2018-05-01
We present a fast numerical screened halo model algorithm (CHAM, which stands for the sCreened HAlo Model) for modelling non-linear power spectrum for the alternative models to Λ cold dark matter. This method has three obvious advantages. First of all, it is not being restricted to a specific dark energy/modified gravity model. In principle, all of the screened scalar-tensor theories can be applied. Secondly, the least assumptions are made in the calculation. Hence, the physical picture is very easily understandable. Thirdly, it is very predictable and does not rely on the calibration from N-body simulation. As an example, we show the case of the Hu-Sawicki f(R) gravity. In this case, the typical CPU time with the current parallel PYTHON script (eight threads) is roughly within 10 min. The resulting spectra are in a good agreement with N-body data within a few percentage accuracy up to k ˜ 1 h Mpc-1.
Context-dependent effects of background colour in free recall with spatially grouped words.
Sakai, Tetsuya; Isarida, Toshiko K; Isarida, Takeo
2010-10-01
Three experiments investigated context-dependent effects of background colour in free recall with groups of items. Undergraduates (N=113) intentionally studied 24 words presented in blocks of 6 on a computer screen with two different background colours. The two background colours were changed screen-by-screen randomly (random condition) or alternately (alternation condition) during the study period. A 30-second filled retention interval was imposed before an oral free-recall test. A signal for free recall was presented throughout the test on one of the colour background screens presented at study. Recalled words were classified as same- or different-context words according to whether the background colours at study and test were the same or different. The random condition produced significant context-dependent effects, whereas the alternation condition showed no context-dependent effects, regardless of whether the words were presented once or twice. Furthermore, the words presented on the same screen were clustered in recall, whereas the words presented against the same background colour but on different screens were not clustered. The present results imply: (1) background colours can cue spatially massed words; (2) background colours act as temporally local context; and (3) predictability of the next background colour modulates the context-dependent effect.
Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening.
Wong, Ling-Tim; Mui, Kwok-Wai; Tsang, Tsz-Wun
2016-12-14
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ₁ (with one parameter: CO₂), θ₂ (with two parameters: CO₂ and respirable suspended particulates, RSP) and θ₃ (with three parameters: CO₂, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported.
Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening
Wong, Ling-tim; Mui, Kwok-wai; Tsang, Tsz-wun
2016-01-01
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ1 (with one parameter: CO2), θ2 (with two parameters: CO2 and respirable suspended particulates, RSP) and θ3 (with three parameters: CO2, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported. PMID:27983667
Hall, A.E.; Chowdhury, S.; Hallowell, N.; Pashayan, N.; Dent, T.; Pharoah, P.; Burton, H.
2014-01-01
Background The identification of common genetic variants associated with common cancers including breast, prostate and ovarian cancers would allow population stratification by genotype to effectively target screening and treatment. As scientific, clinical and economic evidence mounts there will be increasing pressure for risk-stratified screening programmes to be implemented. Methods This paper reviews some of the main ethical, legal and social issues (ELSI) raised by the introduction of genotyping into risk-stratified screening programmes, in terms of Beauchamp and Childress's four principles of biomedical ethics—respect for autonomy, non-maleficence, beneficence and justice. Two alternative approaches to data collection, storage, communication and consent are used to exemplify the ELSI issues that are likely to be raised. Results Ultimately, the provision of risk-stratified screening using genotyping raises fundamental questions about respective roles of individuals, healthcare providers and the state in organizing or mandating such programmes, and the principles, which underpin their provision, particularly the requirement for distributive justice. Conclusions The scope and breadth of these issues suggest that ELSI relating to risk-stratified screening will become increasingly important for policy-makers, healthcare professionals and a wide diversity of stakeholders. PMID:23986542
Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen.
Bamford, J; Fortnum, H; Bristow, K; Smith, J; Vamvakas, G; Davies, L; Taylor, R; Watkin, P; Fonseca, S; Davis, A; Hind, S
2007-08-01
To describe and analyse in detail current practice of school entry hearing screening (SES) in the UK. Main electronic databases were searched up to May 2005. A national postal questionnaire survey was addressed to all leads for SES in the UK, considering current practice in terms of implementation, protocols, target population and performance data. Primary data from cohort studies in one area of London were examined. A systematic review of alternative SES tests, test performance and impact on outcomes was carried out. Finally, a review of published studies on costs, plus economic modelling of current and alternative programmes was prepared. The survey suggested that SES is used in most of England, Wales and Scotland; just over 10% of respondents have abandoned the screen; others are awaiting national guidance. Coverage of SES is variable, but is often over 90% for children in state schools. Referral rates are variable, with a median of about 8%. The test used for the screen is the pure tone sweep test but with wide variation in implementation, with differing frequencies, pass criteria and retest protocols; written examples of protocols were often poor and ambiguous. There is no national approach to data collection, audit and quality assurance, and there are variable approaches at local level. The screen is performed in less than ideal test conditions and resources are often limited, which has an impact on the quality of the screen. The primary cohort studies show that the prevalence of permanent childhood hearing loss continues to increase through infancy. Of the 3.47 in 1000 children with a permanent hearing loss at school screen age, 1.89 in 1000 required identification after the newborn screen. Newborn hearing screening is likely to reduce significantly the yield of SES for permanent bilateral and unilateral hearing impairments; yield had fallen from about 1.11 in 1000 before newborn screening to about 0.34 in 1000 for cohorts that had had newborn screening, of which only 0.07 in 1000 were unilateral impairments. Just under 20% of permanent moderate or greater bilateral, mild bilateral and unilateral impairments, known to services as 6-year-olds or older, remained to be identified around the time of school entry. No good-quality published comparative trials of alternative screens or tests for SES were identified and studies concerned with the relative accuracy of alternative tests are difficult to compare and often flawed by differing referral criteria and case definitions; with full pure tone audiometry as the reference test, the pure tone sweep test appears to have high sensitivity and high specificity for minimal, mild and greater hearing impairments, better than alternative tests for which evidence was identified. There is insufficient evidence regarding possible harm of the screen. There were no published studies identified that examined the possible effects of SES on longer term outcomes. No good-quality published economic evaluations of SES were identified and a universal SES based on pure tone sweep tests was associated with higher costs and slightly higher quality-adjusted life-years (QALYs) compared with no screen and other screen alternatives; the incremental cost-effectiveness ratio for such a screen is around 2500 pounds per QALY gained; the range of expected costs, QALYs and net benefits was broad, indicating a considerable degree of uncertainty. Targeted screening could be more cost-effective than universal school entry screening; however, the lack of primary data and the wide limits for variables in the modelling mean that any conclusions must be considered indicative and exploratory only. A national screening programme for permanent hearing impairment at school entry meets all but three of the criteria for a screening programme, but at least six criteria are not met for screening for temporary hearing impairment. The lack of good-quality evidence in this area remains a serious problem. Services should improve quality and audit screen performance for identification of previously unknown permanent hearing impairment, pending evidence-based policy decisions based on the research recommendations. Further research is needed into a number of important areas including the evaluation of an agreed national protocol for services delivering SES to make future studies and audits of screen performance more directly comparable.
Securing recruitment and obtaining informed consent in minority ethnic groups in the UK.
Lloyd, Cathy E; Johnson, Mark R D; Mughal, Shanaz; Sturt, Jackie A; Collins, Gary S; Roy, Tapash; Bibi, Rukhsana; Barnett, Anthony H
2008-03-30
Previous health research has often explicitly excluded individuals from minority ethnic backgrounds due to perceived cultural and communication difficulties, including studies where there might be language/literacy problems in obtaining informed consent. This study addressed these difficulties by developing audio-recorded methods of obtaining informed consent and recording data. This report outlines 1) our experiences with securing recruitment to a qualitative study investigating alternative methods of data collection, and 2) the development of a standardised process for obtaining informed consent from individuals from minority ethnic backgrounds whose main language does not have an agreed written form. Two researchers from South Asian backgrounds recruited adults with Type 2 diabetes whose main language was spoken and not written, to attend a series of focus groups. A screening tool was used at recruitment in order to assess literacy skills in potential participants. Informed consent was obtained using audio-recordings of the patient information and recording patients' verbal consent. Participants' perceptions of this method of obtaining consent were recorded. Recruitment rates were improved by using telephone compared to face-to-face methods. The screening tool was found to be acceptable by all potential participants. Audio-recorded methods of obtaining informed consent were easy to implement and accepted by all participants. Attrition rates differed according to ethnic group. Snowballing techniques only partly improved participation rates. Audio-recorded methods of obtaining informed consent are an acceptable alternative to written consent in study populations where literacy skills are variable. Further exploration of issues relating to attrition is required, and a range of methods may be necessary in order to maximise response and participation rates.
Cui, Jiangyu; Zhou, Yumin; Tian, Jia; Wang, Xinwang; Zheng, Jingping; Zhong, Nanshan; Ran, Pixin
2012-12-01
COPD is often underdiagnosed in a primary care setting where the spirometry is unavailable. This study was aimed to develop a simple, economical and applicable model for COPD screening in those settings. First we established a discriminant function model based on Bayes' Rule by stepwise discriminant analysis, using the data from 243 COPD patients and 112 non-COPD subjects from our COPD survey in urban and rural communities and local primary care settings in Guangdong Province, China. We then used this model to discriminate COPD in additional 150 subjects (50 non-COPD and 100 COPD ones) who had been recruited by the same methods as used to have established the model. All participants completed pre- and post-bronchodilator spirometry and questionnaires. COPD was diagnosed according to the Global Initiative for Chronic Obstructive Lung Disease criteria. The sensitivity and specificity of the discriminant function model was assessed. THE ESTABLISHED DISCRIMINANT FUNCTION MODEL INCLUDED NINE VARIABLES: age, gender, smoking index, body mass index, occupational exposure, living environment, wheezing, cough and dyspnoea. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, accuracy and error rate of the function model to discriminate COPD were 89.00%, 82.00%, 4.94, 0.13, 86.66% and 13.34%, respectively. The accuracy and Kappa value of the function model to predict COPD stages were 70% and 0.61 (95% CI, 0.50 to 0.71). This discriminant function model may be used for COPD screening in primary care settings in China as an alternative option instead of spirometry.
Trials and projects on cervical cancer and human papillomavirus prevention in sub-Saharan Africa.
Adefuye, Peter O; Broutet, Nathalie J; de Sanjosé, Silvia; Denny, Lynette A
2013-12-29
Cervical cancer is the leading cause of cancer morbidity and mortality in women in sub-Saharan Africa (SSA), accounting for about 50,000 deaths annually. Until recently, cytology was the gold standard for screening and prevention of cervical cancer. This method of screening has not been successful in SSA due to a lack of human, financial and material resources and poor health care infrastructure. It is estimated that less than 5% of at risk women have ever being screened. In the past two decades alternative approaches to cytology for cervical cancer screening have been evaluated in low- and medium-income countries. Visual inspection with acetic acid (VIA) and/or Lugol's iodine (VILI) have been shown to have adequate sensitivity, although low specificity, in a number of cross-sectional research and demonstration projects. Visual inspection methods require minimal resources, are technologically accessible, and are feasible for screening for precancerous lesions. Linking screening with VIA/VILI to treatment with cryotherapy may enable screening and treatment to take place in one visit, but this is likely to result in large numbers of women being subjected to unnecessary treatment. A number of studies have shown that cryotherapy is not associated with significant side effects or complications and is well tolerated. Creating the infrastructure for screening of older women is considered desirable, despite the limitations of visual inspection methods as screening tests. Understanding the role of human papillomavirus (HPV) infection in the etiology of cervical cancer and the discovery of HPV rapid test kits, as well as the development of vaccines against the HPV oncogenic types, have created new opportunities for prevention of cervical cancer. Trials and projects have established (and are still ongoing) the feasibility of using these molecular tests for screening. The ultimate in prevention method is primary prevention, offered by the advent of prophylactic vaccines against the most important oncogenic types, namely HPV16 and 18. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in the Sub-Saharan Africa Region" Vaccine Volume 31, Supplement 5, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2012 Elsevier Ltd. All rights reserved.
System and method for sub-sea cable termination
Chen, Qin; Yin, Weijun; Zhang, Lili
2016-04-05
An electrical connector includes a first cable termination chamber configured to receive a first power cable having at least a first conductor sheathed at least in part by a first insulating layer and a first insulation screen layer. Also, the electrical connector includes a first non-linear resistive layer configured to be coupled to a portion of the first conductor unsheathed by at least the first insulation screen layer and configured to control a direct current electric field generated in the first cable termination chamber. In addition, the electrical connector includes a first deflector configured to be coupled to the first power cable and control an alternating current electric field generated in the first cable termination chamber.
Identification and Screening of Carcass Pretreatment ...
Technical Fact Sheet Managing the treatment and disposal of large numbers of animal carcasses following a foreign animal disease (FAD) outbreak is a challenging endeavor. Pretreatment of the infectious carcasses might facilitate the disposal of the carcasses by simplifying the transportation, reducing the pathogen load in the carcasses, or by isolating the pathogen from the environment to minimize spread of any pathogens.This brief summarizes information contained in U.S. Environmental Protection Agency (EPA) report (EPA/600/R-15/053) entitled Identification and Screening of Infectious Carcass Pretreatment Alternatives. This brief describes how each of eleven pretreatment methods can be used prior to, and in conjunction with, six commonly used large-scale carcass disposal options
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, E.B. Jr.
Various methods for the calculation of lower bounds for eigenvalues are examined, including those of Weinstein, Temple, Bazley and Fox, Gay, and Miller. It is shown how all of these can be derived in a unified manner by the projection technique. The alternate forms obtained for the Gay formula show how a considerably improved method can be readily obtained. Applied to the ground state of the helium atom with a simple screened hydrogenic trial function, this new method gives a lower bound closer to the true energy than the best upper bound obtained with this form of trial function. Possiblemore » routes to further improved methods are suggested.« less
Bishai, David M.; Lőrincz, Attila; Shah, Keerti V.; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge
2010-01-01
Objective To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. Methods A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Results Screening women between the ages of 30–80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. Conclusions This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program. PMID:21170578
Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.
2003-01-01
During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.
Efficient discovery of responses of proteins to compounds using active learning
2014-01-01
Background Drug discovery and development has been aided by high throughput screening methods that detect compound effects on a single target. However, when using focused initial screening, undesirable secondary effects are often detected late in the development process after significant investment has been made. An alternative approach would be to screen against undesired effects early in the process, but the number of possible secondary targets makes this prohibitively expensive. Results This paper describes methods for making this global approach practical by constructing predictive models for many target responses to many compounds and using them to guide experimentation. We demonstrate for the first time that by jointly modeling targets and compounds using descriptive features and using active machine learning methods, accurate models can be built by doing only a small fraction of possible experiments. The methods were evaluated by computational experiments using a dataset of 177 assays and 20,000 compounds constructed from the PubChem database. Conclusions An average of nearly 60% of all hits in the dataset were found after exploring only 3% of the experimental space which suggests that active learning can be used to enable more complete characterization of compound effects than otherwise affordable. The methods described are also likely to find widespread application outside drug discovery, such as for characterizing the effects of a large number of compounds or inhibitory RNAs on a large number of cell or tissue phenotypes. PMID:24884564
To nudge or not to nudge: cancer screening programmes and the limits of libertarian paternalism.
Ploug, Thomas; Holm, Søren; Brodersen, John
2012-12-01
'Nudging--and the underlying idea 'libertarian paternalism'--to an increasing degree influences policy thinking in the healthcare sector. This article discusses the influence exerted upon a woman's choice of participation in the Danish breast screening programme in light of 'libertarian paternalism'. The basic tenet of 'libertarian paternalism' is outlined and the relationship between 'libertarian paternalism' and informed consent investigated. Key elements in the process of enrolling women into the Danish mammography screening programme are introduced. It is shown that for several reasons the influence exerted upon women's choices of participation cannot be justified within a welfare-enhancing libertarian paternalistic framework. The article suggests that screening programmes alternatively adopt a liberty-enhancing approach and considers the practical implications of this alternative.
Vroblesky, Don A.; Borchers, J.W.; Campbell, T.R.; Kinsey, Willey
2000-01-01
Fourteen wells were instrumented with diffusion samplers as a test to determine whether the samplers could be used to obtain representative volatile organic compound concentrations at a study site in Sacramento, California. Single diffusion samplers were placed in 10-foot-long well screens, and multiple diffusion samplers were positioned in 20-foot-long well screens. Borehole geophysical logs and electromagnetic flowmeter tests were run in selected wells with 20-foot-long well screens prior to deploying the samplers. The diffusion samplers were recovered after 25 to 30 days, and the wells were then sampled by using the purge-and-sample method. In most wells, the concentrations obtained by using the downhole diffusion samplers closely matched those obtained by using the purge-and-sample method. In seven wells, the concentrations differed between the two methods by only 2 micrograms per liter (g/L) or less. In three wells, volatile organic compounds were not detected in water obtained by using either method. In the four remaining wells, differences between the methods were less than 2g/L in the 0.2- to 8.5-g/L concentration range and from 1.2 to 8.7g/L in the 10- to 26-g/L concentration range. Greater differences (23 percent or 14.5g/L, 31 percent or 66g/L, and 46 percent or 30g/L) between the two methods were observed for tetrachloroethene concentrations, which ranged between 30 and 211g/L in three wells. The most probable explanation for the differences is that in some wells, the purging induced drawdowns and introduced water that differed in volatile organic compound concentrations from the in situ water in contact with the screened interval of the well. Alternate explanations include the possibility of unrecorded changes in nearby contaminant-extraction-well operation during the equilibration period. The data suggest that the combined use of borehole flowmeter tests and diffusion samplers may be useful in optimizing the radius of capture of contaminated ground water by the contaminant-removal wells. Overall, the data suggest that the use of diffusion samplers provided an alternative sampling method to the purge-and-sample approach. 1U.S. Geological Survey, Stephenson Center, Suite 129, 720 Gracern Road, Columbia, South Carolina 29210-7651. 2U.S. Geological Survey, 6000 J Street, Sacramento, California 95819-6129.
Cost-effectiveness of organized versus opportunistic cervical cytology screening in Hong Kong.
Kim, Jane J; Leung, Gabriel M; Woo, Pauline P S; Goldie, Sue J
2004-06-01
To assess the cost-effectiveness of alternative cervical cancer screening strategies to inform the design and implementation of a government-sponsored population-based screening programme in Hong Kong. Cost-effectiveness analysis using a computer-based model of cervical carcinogenesis was performed. Strategies included no screening, opportunistic screening (status quo), organized screening using either conventional or liquid-based cytology conducted at different frequencies. The main outcome measures were cancer incidence reduction, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios. Data were from local hospitals and laboratories, clinical trials, prospective studies and other published literature. Compared with no screening, a simulation of the current situation of opportunistic screening using cervical cytology produced a nearly 40 per cent reduction in the lifetime risk of cervical cancer. However, with organized screening every 3, 4 and 5 years, corresponding reductions with conventional (and liquid-based) cytology were 90.4 (92.9), 86.8 (90.2) and 83.2 per cent (87.3 per cent) compared with no screening. For all cytology-based screening strategies, opportunistic screening was more costly and less effective than an organized programme of screening every 3, 4 and 5 years. Every 3-, 4- and 5-year screening cost $12,300, $7100 and $800 per YLS, each compared with the next best alternative. Compared with the status quo of opportunistic screening, adopting a policy of organized, mass cervical screening in Hong Kong can substantially increase benefits and reduce costs.
Management of low-grade cervical abnormalities detected at screening: which method do women prefer?
Whynes, D K; Woolley, C; Philips, Z
2008-12-01
To establish whether women with low-grade abnormalities detected during screening for cervical cancer prefer to be managed by cytological surveillance or by immediate colposcopy. TOMBOLA (Trial of Management of Borderline and Other Low-grade Abnormal smears) is a randomized controlled trial comparing alternative management strategies following the screen-detection of low-grade cytological abnormalities. At exit, a sample of TOMBOLA women completed a questionnaire eliciting opinions on their management, contingent valuations (CV) of the management methods and preferences. Within-trial quality of life (EQ-5D) data collected for a sample of TOMBOLA women throughout their follow-up enabled the comparison of self-reported health at various time points, by management method. Once management had been initiated, self-reported health in the colposcopy arm rose relative to that in the surveillance arm, although the effect was short-term only. For the majority of women, the satisfaction ratings and the CV indicated approval of the management method to which they had been randomized. Of the minority manifesting a preference for the method which they had not experienced, relatively more would have preferred colposcopy than would have preferred surveillance. The findings must be interpreted in the light of sample bias with respect to preferences, whereby enthusiasm for colposcopy was probably over-represented amongst trial participants. The study suggests that neither of the management methods is preferred unequivocally; rather, individual women have individual preferences, although many would be indifferent between methods.
Recovery and purification process development for monoclonal antibody production
Ma, Junfen; Winter, Charles; Bayer, Robert
2010-01-01
Hundreds of therapeutic monoclonal antibodies (mAbs) are currently in development, and many companies have multiple antibodies in their pipelines. Current methodology used in recovery processes for these molecules are reviewed here. Basic unit operations such as harvest, Protein A affinity chromatography and additional polishing steps are surveyed. Alternative processes such as flocculation, precipitation and membrane chromatography are discussed. We also cover platform approaches to purification methods development, use of high throughput screening methods, and offer a view on future developments in purification methodology as applied to mAbs. PMID:20647768
Brennan, Marie-Luise; Schrijver, Iris
2016-01-01
Cystic fibrosis (CF) is an autosomal recessive disease with significant associated morbidity and mortality. It is now appreciated that the broad phenotypic CF spectrum is not explained by obvious genotype-phenotype correlations, suggesting that CF transmembrane conductance regulator (CFTR)-related disease may occur because of multiple additive effects. These contributing effects include complex CFTR alleles, modifier genes, mutations in alternative genes that produce CF-like phenotypes, epigenetic factors, and environmental influences. Most patients in the United States are now diagnosed through newborn screening and use of molecular testing methods. We review the molecular testing approaches and laboratory guidelines for carrier screening, prenatal testing, newborn screening, and clinical diagnostic testing, as well as recent developments in CF treatment, and reasons for the lack of a molecular diagnosis in some patients. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Heitner, Tara; Satozawa, Noboru; McLean, Kirk; Vogel, David; Cobb, Ronald R; Liu, Bing; Mahmoudi, Mithra; Finster, Silke; Larsen, Brent; Zhu, Ying; Zhou, Hongxing; Müller-Tiemann, Beate; Monteclaro, Felipe; Zhao, Xiao-Yan; Light, David R
2006-12-01
A therapeutic antibody candidate (AT-19) isolated using multivalent phage display binds native tomoregulin (TR) as a mul-timer not as a monomer. This report raises the importance of screening and selecting phage antibodies on native antigen and reemphasizes the possibility that potentially valuable antibodies are discarded when a monomeric phage display system is used for screening. A detailed live cell panning selection and screening method to isolate multivalently active antibodies is described. AT-19 is a fully human antibody recognizing the cell surface protein TR, a proposed prostate cancer target for therapeutic antibody internalization. AT-19 was isolated from a multivalent single-chain variable fragment (scFv) antibody library rescued with hyperphage. The required multivalency for isolation of AT-19 is supported by fluorescence activated cell sorting data demonstrating binding of the multivalent AT-19 phage particles at high phage concentrations and failure of monovalent particles to bind. Pure monomeric scFv AT-19 does not bind native receptor on cells, whereas dimeric scFv or immunoglobulin G binds with nanomolar affinity. The isolation of AT-19 antibody with obligate bivalent binding activity to native TR is attributed to the use of a multivalent display of scFv on phage and the method for selecting and screening by alternate use of 2 recombinant cell lines.
ERIC Educational Resources Information Center
Salerno, Jennifer; Darling-Fisher, Cindy; Hawkins, Nicole M.; Fraker, Elizabeth
2013-01-01
Background: This article describes a school-wide sexually transmitted infection (STI) screening to identify adolescent high-risk sexual behaviors, STI history/incidence, and presence of chlamydia and gonorrhea, and examines relationships between high-risk behaviors and screening positive for chlamydia and gonorrhea in an alternative high school…
Dynamic undocking and the quasi-bound state as tools for drug discovery
NASA Astrophysics Data System (ADS)
Ruiz-Carmona, Sergio; Schmidtke, Peter; Luque, F. Javier; Baker, Lisa; Matassova, Natalia; Davis, Ben; Roughley, Stephen; Murray, James; Hubbard, Rod; Barril, Xavier
2017-03-01
There is a pressing need for new technologies that improve the efficacy and efficiency of drug discovery. Structure-based methods have contributed towards this goal but they focus on predicting the binding affinity of protein-ligand complexes, which is notoriously difficult. We adopt an alternative approach that evaluates structural, rather than thermodynamic, stability. As bioactive molecules present a static binding mode, we devised dynamic undocking (DUck), a fast computational method to calculate the work necessary to reach a quasi-bound state at which the ligand has just broken the most important native contact with the receptor. This non-equilibrium property is surprisingly effective in virtual screening because true ligands form more-resilient interactions than decoys. Notably, DUck is orthogonal to docking and other 'thermodynamic' methods. We demonstrate the potential of the docking-undocking combination in a fragment screening against the molecular chaperone and oncology target Hsp90, for which we obtain novel chemotypes and a hit rate that approaches 40%.
Schwaighofer, Andreas; Kuligowski, Julia; Quintás, Guillermo; Mayer, Helmut K; Lendl, Bernhard
2018-06-30
Analysis of proteins in bovine milk is usually tackled by time-consuming analytical approaches involving wet-chemical, multi-step sample clean-up procedures. The use of external cavity-quantum cascade laser (EC-QCL) based IR spectroscopy was evaluated as an alternative screening tool for direct and simultaneous quantification of individual proteins (i.e. casein and β-lactoglobulin) and total protein content in commercial bovine milk samples. Mid-IR spectra of protein standard mixtures were used for building partial least squares (PLS) regression models. A sample set comprising different milk types (pasteurized; differently processed extended shelf life, ESL; ultra-high temperature, UHT) was analysed and results were compared to reference methods. Concentration values of the QCL-IR spectroscopy approach obtained within several minutes are in good agreement with reference methods involving multiple sample preparation steps. The potential application as a fast screening method for estimating the heat load applied to liquid milk is demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.
Screening large-scale association study data: exploiting interactions using random forests.
Lunetta, Kathryn L; Hayward, L Brooke; Segal, Jonathan; Van Eerdewegh, Paul
2004-12-10
Genome-wide association studies for complex diseases will produce genotypes on hundreds of thousands of single nucleotide polymorphisms (SNPs). A logical first approach to dealing with massive numbers of SNPs is to use some test to screen the SNPs, retaining only those that meet some criterion for further study. For example, SNPs can be ranked by p-value, and those with the lowest p-values retained. When SNPs have large interaction effects but small marginal effects in a population, they are unlikely to be retained when univariate tests are used for screening. However, model-based screens that pre-specify interactions are impractical for data sets with thousands of SNPs. Random forest analysis is an alternative method that produces a single measure of importance for each predictor variable that takes into account interactions among variables without requiring model specification. Interactions increase the importance for the individual interacting variables, making them more likely to be given high importance relative to other variables. We test the performance of random forests as a screening procedure to identify small numbers of risk-associated SNPs from among large numbers of unassociated SNPs using complex disease models with up to 32 loci, incorporating both genetic heterogeneity and multi-locus interaction. Keeping other factors constant, if risk SNPs interact, the random forest importance measure significantly outperforms the Fisher Exact test as a screening tool. As the number of interacting SNPs increases, the improvement in performance of random forest analysis relative to Fisher Exact test for screening also increases. Random forests perform similarly to the univariate Fisher Exact test as a screening tool when SNPs in the analysis do not interact. In the context of large-scale genetic association studies where unknown interactions exist among true risk-associated SNPs or SNPs and environmental covariates, screening SNPs using random forest analyses can significantly reduce the number of SNPs that need to be retained for further study compared to standard univariate screening methods.
Ku, Bon Ki; Deye, Gregory J.; Turkevich, Leonid A.
2015-01-01
Fiber dimension (especially length) and biopersistence are thought to be important variables in determining the pathogenicity of asbestos and other elongate mineral particles. In order to prepare samples of fibers for toxicology studies, it is necessary to develop and evaluate methods for separating fibers by length in the micrometer size range. In this study, we have filtered an aerosol of fibers through nylon screens to investigate whether such screens can efficiently remove the long fibers (L >20 μm, a typical macrophage size) from the aerosol stream. Such a sample, deficient in long fibers, could then be used as the control in a toxicology study to investigate the role of length. A well-dispersed aerosol of glass fibers (a surrogate for asbestos) was generated by vortex shaking a Japan Fibrous Material Research Association (JFMRA) glass fiber powder. Fibers were collected on a mixed cellulose ester (MCE) filter, imaged with phase contrast microscopy (PCM) and lengths were measured. Length distributions of the fibers that penetrated through various screens (10, 20 and 60 μm mesh sizes) were analyzed; additional study was made of fibers that penetrated through double screen and centrally blocked screen configurations. Single screens were not particularly efficient in removing the long fibers; however, the alternative configurations, especially the centrally blocked screen configuration, yielded samples substantially free of the long fibers. PMID:24417374
McCormick, M K; Campbell, E; Deaven, L; Moyzis, R
1993-01-01
Construction of chromosome-specific yeast artificial chromosome (YAC) libraries from sorted chromosomes was undertaken (i) to eliminate drawbacks associated with first-generation total genomic YAC libraries, such as the high frequency of chimeric YACs, and (ii) to provide an alternative method for generating chromosome-specific YAC libraries in addition to isolating such collections from a total genomic library. Chromosome-specific YAC libraries highly enriched for human chromosomes 16 and 21 were constructed. By maximizing the percentage of fragments with two ligatable ends and performing yeast transformations with less than saturating amounts of DNA in the presence of carrier DNA, YAC libraries with a low percentage of chimeric clones were obtained. The smaller number of YAC clones in these chromosome-specific libraries reduces the effort involved in PCR-based screening and allows hybridization methods to be a manageable screening approach. Images PMID:8430075
Chan, Christine L; Pyle, Laura; Kelsey, Megan; Newnes, Lindsey; Zeitler, Philip S; Nadeau, Kristen J
2016-05-01
Hemoglobin A1c (HbA1c) is increasingly performed over the oral glucose tolerance test (OGTT) as the initial screening test for type 2 diabetes in youth. However, the optimal strategy for identifying type 2 diabetes in youth remains controversial. Alternate glycemic markers have been proposed as potentially useful tools for diabetes screening. We examined the relationships among fructosamine (FA), glycated albumin (GA), and 1,5-anhydroglucitol (1,5-AG) with traditional screening tests, HbA1c and OGTT. Youth 10-18 yrs, BMI ≥85th‰, and HbA1c <7.5% had a single visit with measurement of HbA1c, 1,5-AG, FA, GA, and a standard OGTT. Distributions of FA, GA, and 1,5-AG by HbA1c and 2-hour glucose (2hG) categories were compared. Receiver operating characteristic (ROC)-curves were generated to determine the cut points at which alternate markers maximized sensitivity and specificity for predicting prediabetes and diabetes. One hundred and seventeen, 62% female, 59% Hispanic, 22% White, 17% black, median 14.1 yr, and body mass index (BMI) z-score 2.3 participated. Median values of each alternate marker differed significantly between prediabetes and diabetes HbA1c and 2hG categories (p < 0.017). Only GA medians differed (p = 0.006) between normal and prediabetes HbA1c. Area under the receiver operating characteristic curves (ROC-AUCs) for alternate markers as predictors of prediabetes (0.5-0.66) were low; however, alternate marker ROC-AUCs for identifying diabetes (0.82-0.98) were excellent. Although the alternate markers were poor predictors of prediabetes, they all performed well predicting diabetes by 2hG and HbA1c. Whereas the usefulness of these markers for identifying prediabetes is limited, they may be useful in certain scenarios as second line screening tools for diabetes in overweight/obese youth. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
An economic evaluation of a genetic screening program for Tay-Sachs disease.
Nelson, W B; Swint, J M; Caskey, C T
1978-01-01
The resolution of policy questions relating to medical genetic screening programs will not be without considerable difficulty. Examples include such issues as the optimal degree of screening program expansion, the relative values of screening for different genetic diseases, the appropriate sources of program funding (public vs. private), and the relative value of funding expanded genetic screening programs vs. research directed toward elimination of genetic traits themselves. Information on the net impact of the relevant alternatives is greatly needed, and this need will increase if the National Genetics Act receives funding approval. We have provided what is hopefully a contribution toward this end. While our analysis pertains to a specific disease and a specific screening program for that disease, the methodology is readily generalizable to other genetic diseases, as well as programs of any size or structure. Hopefully, this will serve to stimulate further research efforts that we believe are needed for the objective consideration of resource allocation alternatives. PMID:418675
An economic evaluation of a genetic screening program for Tay-Sachs disease.
Nelson, W B; Swint, J M; Caskey, C T
1978-03-01
The resolution of policy questions relating to medical genetic screening programs will not be without considerable difficulty. Examples include such issues as the optimal degree of screening program expansion, the relative values of screening for different genetic diseases, the appropriate sources of program funding (public vs. private), and the relative value of funding expanded genetic screening programs vs. research directed toward elimination of genetic traits themselves. Information on the net impact of the relevant alternatives is greatly needed, and this need will increase if the National Genetics Act receives funding approval. We have provided what is hopefully a contribution toward this end. While our analysis pertains to a specific disease and a specific screening program for that disease, the methodology is readily generalizable to other genetic diseases, as well as programs of any size or structure. Hopefully, this will serve to stimulate further research efforts that we believe are needed for the objective consideration of resource allocation alternatives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaikuad, Apirat, E-mail: apirat.chaikuad@sgc.ox.ac.uk; Knapp, Stefan; Johann Wolfgang Goethe-University, Building N240 Room 3.03, Max-von-Laue-Strasse 9, 60438 Frankfurt am Main
An alternative strategy for PEG sampling is suggested through the use of four newly defined PEG smears to enhance chemical space in reduced screens with a benefit towards protein crystallization. The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially availablemore » crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.« less
NASA Astrophysics Data System (ADS)
Lam, Carl
Due to technology proliferation, the environmental burden attributed to the production, use, and disposal of hazardous materials in electronics have become a worldwide concern. The major theme of this dissertation is to develop and apply hazardous materials assessment tools to systematically guide pollution prevention opportunities in the context of electronic product design, manufacturing and end-of-life waste management. To this extent, a comprehensive review is first provided on describing hazard traits and current assessment methods to evaluate hazardous materials. As a case study at the manufacturing level, life cycle impact assessment (LCIA)-based and risk-based screening methods are used to quantify chemical and geographic environmental impacts in the U.S. printed wiring board (PWB) industry. Results from this industrial assessment clarify priority waste streams and States to most effectively mitigate impact. With further knowledge of PWB manufacturing processes, select alternative chemical processes (e.g., spent copper etchant recovery) and material options (e.g., lead-free etch resist) are discussed. In addition, an investigation on technology transition effects for computers and televisions in the U.S. market is performed by linking dynamic materials flow and environmental assessment models. The analysis forecasts quantities of waste units generated and maps shifts in environmental impact potentials associated with metal composition changes due to product substitutions. This insight is important to understand the timing and waste quantities expected and the emerging toxic elements needed to be addressed as a consequence of technology transition. At the product level, electronic utility meter devices are evaluated to eliminate hazardous materials within product components. Development and application of a component Toxic Potential Indicator (TPI) assessment methodology highlights priority components requiring material alternatives. Alternative recommendations are provided and substitute materials such as aluminum alloys for stainless steel and high-density polyethylene for polyvinyl chloride and acrylonitrile-based polymers show promise to meet toxicity reduction, cost, and material functionality requirements. Furthermore, the TPI method, an European Union focused screening tool, is customized to reflect regulated U.S. toxicity parameters. Results show that, although it is possible to adopt U.S. parameters into the TPI method, harmonization of toxicity regulation and standards in various nations and regions is necessary to eliminate inconsistencies during hazard screening of substances used globally. As a whole, the present work helps to assimilate material hazard assessment methods into the larger framework of design for environment strategies so toxics use reduction could be achieved for the development and management of electronics and other consumer goods.
Björnsdotter, Maria K; Jonker, Willem; Legradi, Jessica; Kool, Jeroen; Ballesteros-Gómez, Ana
2017-12-01
Thermal paper contains potentially toxic additives, such as bisphenol A (BPA), as a common color developer. Because of its known endocrine disrupting effects, structural analogues to BPA, such as bisphenol S (BPS), D-8 and Pergafast 201, have been used as alternatives, but little is known about the presence and toxicological effects of alternatives other than BPS. In this study, thermal paper is screened by direct probe ambient mass spectrometry (rapid pre-screening method not requiring sample preparation) and by liquid chromatography (LC) with high resolution time-of flight (TOF-MS) mass spectrometry. Cash receipts and other thermal paper products (cinema tickets, boarding passes and luggage tags) were analyzed. Besides BPA and BPS, other developers only recently reported (Pergafast 201, D-8) or to the best of our knowledge not reported before (D-90, TGSA, BPS-MAE) were frequently found as well as some related unreported impurities (2,4-BPS that is a BPS related impurity and a TGSA related impurity). To gain some insight into the potential estrogenicity of the detected developers, a selection of extracts was further analyzed using a LC-nanofractionation platform in combination with cell-based bioassay testing. These preliminary results seems to indicate very low or absence of estrogenic activity for Pergafast 201, D-8, D-90, TGSA and BPS-MAE in comparison to BPA and BPS, although further dose-response tests with authentic standards are required to confirm these results. Compounds for which standards were available were also tested for developmental toxicity and neurotoxicity using zebrafish (Danio rerio) embryos. TGSA and D-8 induced similar teratogenic effects as BPA in zebrafish embryos. BPS and 2,4-BPS did not induce any developmental effects but 2,4-BPS did alter the locomotor activity at the tested concentration. Our findings suggest that the alternatives used as alternatives to BPA (except BPS) might not be estrogenic. However, TGSA and D-8 showed abnormal developmental effects similar to BPA. Copyright © 2017 Elsevier B.V. All rights reserved.
Exploring the acceptability of human papillomavirus self-sampling among Muslim immigrant women.
Lofters, Aisha K; Vahabi, Mandana; Fardad, Mitra; Raza, Afrah
2017-01-01
With appropriate screening (ie, the Papanicolaou [Pap] test), cervical cancer is highly preventable, and high-income countries, including Canada, have observed significant decreases in cervical cancer mortality. However, certain subgroups, including immigrants from countries with large Muslim populations, experience disparities in cervical cancer screening. Little is known about the acceptability of human papillomavirus (HPV) self-sampling as a screening strategy among Muslim immigrant women in Canada. This study assessed cervical cancer screening practices, knowledge and attitudes, and acceptability of HPV self-sampling among Muslim immigrant women. A convenience sample of 30 women was recruited over a 3-month period (June-August 2015) in the Greater Toronto Area. All women were between 21 and 69 years old, foreign-born, and self-identified as Muslim, and had good knowledge of English. Data were collected through a self-completed questionnaire. More than half of the participants falsely indicated that Pap tests may cause cervical infection, and 46.7% indicated that the test is an intrusion on privacy. The majority of women reported that they would be willing to try HPV self-sampling, and more than half would prefer this method to provider-administered sampling methods. Barriers to self-sampling included confidence in the ability to perform the test and perceived cost, and facilitators included convenience and privacy being preserved. The results demonstrate that HPV self-sampling may provide a favorable alternative model of care to the traditional provider-administered Pap testing. These findings add important information to the literature related to promoting cancer screening among women who are under or never screened for cervical cancer.
Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.
2010-01-01
Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614
2013-01-01
Background Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. Methods A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55–74 years, and (c) biennial faecal immunochemical tests (FIT) at 55–74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55–64 years) and staggered age-based roll-out across the 55–74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55–74). Results FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381–1,053 with FSIG-based, and 967–1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. Conclusions While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning. PMID:23510135
Nir, Oaz; Bakal, Chris; Perrimon, Norbert; Berger, Bonnie
2010-03-01
Biological networks are highly complex systems, consisting largely of enzymes that act as molecular switches to activate/inhibit downstream targets via post-translational modification. Computational techniques have been developed to perform signaling network inference using some high-throughput data sources, such as those generated from transcriptional and proteomic studies, but comparable methods have not been developed to use high-content morphological data, which are emerging principally from large-scale RNAi screens, to these ends. Here, we describe a systematic computational framework based on a classification model for identifying genetic interactions using high-dimensional single-cell morphological data from genetic screens, apply it to RhoGAP/GTPase regulation in Drosophila, and evaluate its efficacy. Augmented by knowledge of the basic structure of RhoGAP/GTPase signaling, namely, that GAPs act directly upstream of GTPases, we apply our framework for identifying genetic interactions to predict signaling relationships between these proteins. We find that our method makes mediocre predictions using only RhoGAP single-knockdown morphological data, yet achieves vastly improved accuracy by including original data from a double-knockdown RhoGAP genetic screen, which likely reflects the redundant network structure of RhoGAP/GTPase signaling. We consider other possible methods for inference and show that our primary model outperforms the alternatives. This work demonstrates the fundamental fact that high-throughput morphological data can be used in a systematic, successful fashion to identify genetic interactions and, using additional elementary knowledge of network structure, to infer signaling relations.
NASA Astrophysics Data System (ADS)
Holland, Katharina; van Gils, Carla H.; Wanders, Johanna OP; Mann, Ritse M.; Karssemeijer, Nico
2016-03-01
The sensitivity of mammograms is low for women with dense breasts, since cancers may be masked by dense tissue. In this study, we investigated methods to identify women with density patterns associated with a high masking risk. Risk measures are derived from volumetric breast density maps. We used the last negative screening mammograms of 93 women who subsequently presented with an interval cancer (IC), and, as controls, 930 randomly selected normal screening exams from women without cancer. Volumetric breast density maps were computed from the mammograms, which provide the dense tissue thickness at each location. These were used to compute absolute and percentage glandular tissue volume. We modeled the masking risk for each pixel location using the absolute and percentage dense tissue thickness and we investigated the effect of taking the cancer location probability distribution (CLPD) into account. For each method, we selected cases with the highest masking measure (by thresholding) and computed the fraction of ICs as a function of the fraction of controls selected. The latter can be interpreted as the negative supplemental screening rate (NSSR). Between the models, when incorporating CLPD, no significant differences were found. In general, the methods performed better when CLPD was included. At higher NSSRs some of the investigated masking measures had a significantly higher performance than volumetric breast density. These measures may therefore serve as an alternative to identify women with a high risk for a masked cancer.
Cost-effectiveness of cervical cancer screening with primary human papillomavirus testing in Norway
Burger, E A; Ortendahl, J D; Sy, S; Kristiansen, I S; Kim, J J
2012-01-01
Background: New screening technologies and vaccination against human papillomavirus (HPV), the necessary cause of cervical cancer, may impact optimal approaches to prevent cervical cancer. We evaluated the cost-effectiveness of alternative screening strategies to inform cervical cancer prevention guidelines in Norway. Methods: We leveraged the primary epidemiologic and economic data from Norway to contextualise a simulation model of HPV-induced cervical cancer. The current cytology-only screening was compared with strategies involving cytology at younger ages and primary HPV-based screening at older ages (31/34+ years), an option being actively deliberated by the Norwegian government. We varied the switch-age, screening interval, and triage strategies for women with HPV-positive results. Uncertainty was evaluated in sensitivity analysis. Results: Current cytology-only screening was less effective and more costly than strategies that involve switching to primary HPV testing in older ages. For unvaccinated women, switching at age 34 years to primary HPV testing every 4 years was optimal given the Norwegian cost-effectiveness threshold ($83 000 per year of life saved). For vaccinated women, a 6-year screening interval was cost-effective. When we considered a wider range of strategies, we found that an earlier switch to HPV testing (at age 31 years) may be preferred. Conclusions: Strategies involving a switch to HPV testing for primary screening in older women is expected to be cost-effective compared with current recommendations in Norway. PMID:22441643
Alternative Test Methods for Electronic Parts
NASA Technical Reports Server (NTRS)
Plante, Jeannette
2004-01-01
It is common practice within NASA to test electronic parts at the manufacturing lot level to demonstrate, statistically, that parts from the lot tested will not fail in service using generic application conditions. The test methods and the generic application conditions used have been developed over the years through cooperation between NASA, DoD, and industry in order to establish a common set of standard practices. These common practices, found in MIL-STD-883, MIL-STD-750, military part specifications, EEE-INST-002, and other guidelines are preferred because they are considered to be effective and repeatable and their results are usually straightforward to interpret. These practices can sometimes be unavailable to some NASA projects due to special application conditions that must be addressed, such as schedule constraints, cost constraints, logistical constraints, or advances in the technology that make the historical standards an inappropriate choice for establishing part performance and reliability. Alternate methods have begun to emerge and to be used by NASA programs to test parts individually or as part of a system, especially when standard lot tests cannot be applied. Four alternate screening methods will be discussed in this paper: Highly accelerated life test (HALT), forward voltage drop tests for evaluating wire-bond integrity, burn-in options during or after highly accelerated stress test (HAST), and board-level qualification.
de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen
2014-04-01
Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kaku, Hiroki; Inoue, Kanako; Muranaka, Yoshinori; Park, Pyoyun; Ikeda, Kenichi
2015-10-01
Uranyl salts are toxic and radioactive; therefore, several studies have been conducted to screen for substitutes of electron stains. In this regard, the contrast evaluation process is time consuming and the results obtained are inconsistent. In this study, we developed a novel contrast evaluation method using affinity beads and a backscattered electron image (BSEI), obtained using scanning electron microscopy. The contrast ratios of BSEI in each electron stain treatment were correlated with those of transmission electron microscopic images. The affinity beads bound to cell components independently. Protein and DNA samples were enhanced by image contrast treated with electron stains; however, this was not observed for sugars. Protein-conjugated beads showed an additive effect of image contrast when double-stained with lead. However, additive effect of double staining was not observed in DNA-conjugated beads. The varying chemical properties of oligopeptides showed differences in image contrast when treated with each electron stain. This BSEI-based evaluation method not only enables screening for alternate electron stains, but also helps analyze the underlying mechanisms of electron staining of cellular structures. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Adetiba, Emmanuel; Olugbara, Oludayo O
2015-01-01
Lung cancer is one of the diseases responsible for a large number of cancer related death cases worldwide. The recommended standard for screening and early detection of lung cancer is the low dose computed tomography. However, many patients diagnosed die within one year, which makes it essential to find alternative approaches for screening and early detection of lung cancer. We present computational methods that can be implemented in a functional multi-genomic system for classification, screening and early detection of lung cancer victims. Samples of top ten biomarker genes previously reported to have the highest frequency of lung cancer mutations and sequences of normal biomarker genes were respectively collected from the COSMIC and NCBI databases to validate the computational methods. Experiments were performed based on the combinations of Z-curve and tetrahedron affine transforms, Histogram of Oriented Gradient (HOG), Multilayer perceptron and Gaussian Radial Basis Function (RBF) neural networks to obtain an appropriate combination of computational methods to achieve improved classification of lung cancer biomarker genes. Results show that a combination of affine transforms of Voss representation, HOG genomic features and Gaussian RBF neural network perceptibly improves classification accuracy, specificity and sensitivity of lung cancer biomarker genes as well as achieving low mean square error.
Predictive Models for Carcinogenicity and Mutagenicity ...
Mutagenicity and carcinogenicity are endpoints of major environmental and regulatory concern. These endpoints are also important targets for development of alternative methods for screening and prediction due to the large number of chemicals of potential concern and the tremendous cost (in time, money, animals) of rodent carcinogenicity bioassays. Both mutagenicity and carcinogenicity involve complex, cellular processes that are only partially understood. Advances in technologies and generation of new data will permit a much deeper understanding. In silico methods for predicting mutagenicity and rodent carcinogenicity based on chemical structural features, along with current mutagenicity and carcinogenicity data sets, have performed well for local prediction (i.e., within specific chemical classes), but are less successful for global prediction (i.e., for a broad range of chemicals). The predictivity of in silico methods can be improved by improving the quality of the data base and endpoints used for modelling. In particular, in vitro assays for clastogenicity need to be improved to reduce false positives (relative to rodent carcinogenicity) and to detect compounds that do not interact directly with DNA or have epigenetic activities. New assays emerging to complement or replace some of the standard assays include VitotoxTM, GreenScreenGC, and RadarScreen. The needs of industry and regulators to assess thousands of compounds necessitate the development of high-t
Aragó, Miriam; Ariño, Cristina; Dago, Àngela; Díaz-Cruz, José Manuel; Esteban, Miquel
2016-11-01
Catechol (CC), resorcinol (RC) and hydroquinone (HQ) are dihydroxybenzene isomers that usually coexist in different samples and can be determined using voltammetric techniques taking profit of their fast response, high sensitivity and selectivity, cheap instrumentation, simple and timesaving operation modes. However, a strong overlapping of CC and HQ signals is observed hindering their accurate analysis. In the present work, the combination of differential pulse voltammetry with graphene screen-printed electrodes (allowing detection limits of 2.7, 1.7 and 2.4µmolL(-1) for HQ, CC and RC respectively) and the data analysis by partial least squares calibration (giving root mean square errors of prediction, RMSEP values, of 2.6, 4.1 and 2.3 for HQ, CC and RC respectively) has been proposed as a powerful tool for the quantification of mixtures of these dihydroxybenzene isomers. The commercial availability of the screen-printed devices and the low cost and simplicity of the analysis suggest that the proposed method can be a valuable alternative to chromatographic and electrophoretic methods for the considered species. The method has been applied to the analysis of these isomers in spiked tap water. Copyright © 2016 Elsevier B.V. All rights reserved.
Calear, Alison L.; Sunderland, Matthew; Carragher, Natacha; Brewer, Jacqueline L.
2016-01-01
Background Community-based screening for mental health problems may increase service use through feedback to individuals about their severity of symptoms and provision of contacts for appropriate services. Aims The effect of symptom feedback on service use was assessed. Secondary outcomes included symptom change and study attrition. Method Using online recruitment, 2773 participants completed a comprehensive survey including screening for depression (n=1366) or social anxiety (n=1407). Across these two versions, approximately half (n=1342) of the participants were then randomly allocated to receive tailored feedback. Participants were reassessed after 3 months (Australian New Zealand Clinical Trials Registry ANZCTR12614000324617). Results A negative effect of providing social anxiety feedback to individuals was observed, with significant reductions in professional service use. Greater attrition and lower intentions to seek help were also observed after feedback. Conclusions Online mental health screening with feedback is not effective for promoting professional service use. Alternative models of online screening require further investigation. Declaration of interest None. Copyright and usage © The Royal College of Psychiatrists 2016. This is an open access article distributed under the terms of the Creative Commons Non-Commercial, No Derivatives (CC BY-NC-ND) licence. PMID:27703756
A mass spectrometer based explosives trace detector
NASA Astrophysics Data System (ADS)
Vilkov, Andrey; Jorabchi, Kaveh; Hanold, Karl; Syage, Jack A.
2011-05-01
In this paper we describe the application of mass spectrometry (MS) to the detection of trace explosives. We begin by reviewing the issue of explosives trace detection (ETD) and describe the method of mass spectrometry (MS) as an alternative to existing technologies. Effective security screening devices must be accurate (high detection and low false positive rate), fast and cost effective (upfront and operating costs). Ion mobility spectrometry (IMS) is the most commonly deployed method for ETD devices. Its advantages are compact size and relatively low price. For applications requiring a handheld detector, IMS is an excellent choice. For applications that are more stationary (e.g., checkpoint and alternatives to IMS are available. MS is recognized for its superior performance with regard to sensitivity and specificity, which translate to lower false negative and false positive rates. In almost all applications outside of security where accurate chemical analysis is needed, MS is usually the method of choice and is often referred to as the gold standard for chemical analysis. There are many review articles and proceedings that describe detection technologies for explosives. 1,2,3,4 Here we compare MS and IMS and identify the strengths and weaknesses of each method. - Mass spectrometry (MS): MS offers high levels of sensitivity and specificity compared to other technologies for chemical detection. Its traditional disadvantages have been high cost and complexity. Over the last few years, however, the economics have greatly improved and MS is now capable of routine and automated operation. Here we compare MS and IMS and identify the strengths and weaknesses of each method. - Ion mobility spectrometry (IMS): 5 MS-ETD Screening System IMS is similar in concept to MS except that the ions are dispersed by gas-phase viscosity and not by molecular weight. The main advantage of IMS is that it does not use a vacuum system, which greatly reduces the size, cost, and complexity relative to MS. However, the trade-off is that the measurement accuracy is considerably less than MS. This is especially true for complex samples or when screening for a large number of target compounds simultaneously.
Characterization of glycoprotein biopharmaceutical products by Caliper LC90 CE-SDS gel technology.
Chen, Grace; Ha, Sha; Rustandi, Richard R
2013-01-01
Over the last decade, science has greatly improved in the area of protein sizing and characterization. Efficient high-throughput methods are now available to substitute for the traditional labor-intensive SDS-PAGE methods, which alternatively take days to analyze a very limited number of samples. Currently, PerkinElmer(®) (Caliper) has designed an automated chip-based fluorescence detection method capable of analyzing proteins in minutes with sensitivity similar to standard SDS-PAGE. Here, we describe the use and implementation of this technology to characterize and screen a large number of formulations of target glycoproteins in the 14-200 kDa molecular weight range.
Codon Optimizing for Increased Membrane Protein Production: A Minimalist Approach.
Mirzadeh, Kiavash; Toddo, Stephen; Nørholm, Morten H H; Daley, Daniel O
2016-01-01
Reengineering a gene with synonymous codons is a popular approach for increasing production levels of recombinant proteins. Here we present a minimalist alternative to this method, which samples synonymous codons only at the second and third positions rather than the entire coding sequence. As demonstrated with two membrane-embedded transporters in Escherichia coli, the method was more effective than optimizing the entire coding sequence. The method we present is PCR based and requires three simple steps: (1) the design of two PCR primers, one of which is degenerate; (2) the amplification of a mini-library by PCR; and (3) screening for high-expressing clones.
DEVELOPMENT OF AN OBJECTIVE AND QUANTIFIABLE TERATOLOGICAL SCREEN FOR USE IN ZEBRAFISH LARVAE.
To address EPA’s need to prioritize large numbers of chemicals for testing, a rapid, cost-effective in vivo screen for potential developmental toxicity using an alternative vertebrate species (zebrafish;Danio rerio) has been developed. A component of that screen is the observatio...
Melo, Carlos Fernando Odir Rodrigues; Navarro, Luiz Claudio; de Oliveira, Diogo Noin; Guerreiro, Tatiane Melina; Lima, Estela de Oliveira; Delafiori, Jeany; Dabaja, Mohamed Ziad; Ribeiro, Marta da Silva; de Menezes, Maico; Rodrigues, Rafael Gustavo Martins; Morishita, Karen Noda; Esteves, Cibele Zanardi; de Amorim, Aline Lopes Lucas; Aoyagui, Caroline Tiemi; Parise, Pierina Lorencini; Milanez, Guilherme Paier; do Nascimento, Gabriela Mansano; Ribas Freitas, André Ricardo; Angerami, Rodrigo; Costa, Fábio Trindade Maranhão; Arns, Clarice Weis; Resende, Mariangela Ribeiro; Amaral, Eliana; Junior, Renato Passini; Ribeiro-do-Valle, Carolina C; Milanez, Helaine; Moretti, Maria Luiza; Proenca-Modena, Jose Luiz; Avila, Sandra; Rocha, Anderson; Catharino, Rodrigo Ramos
2018-01-01
Recent Zika outbreaks in South America, accompanied by unexpectedly severe clinical complications have brought much interest in fast and reliable screening methods for ZIKV (Zika virus) identification. Reverse-transcriptase polymerase chain reaction (RT-PCR) is currently the method of choice to detect ZIKV in biological samples. This approach, nonetheless, demands a considerable amount of time and resources such as kits and reagents that, in endemic areas, may result in a substantial financial burden over affected individuals and health services veering away from RT-PCR analysis. This study presents a powerful combination of high-resolution mass spectrometry and a machine-learning prediction model for data analysis to assess the existence of ZIKV infection across a series of patients that bear similar symptomatic conditions, but not necessarily are infected with the disease. By using mass spectrometric data that are inputted with the developed decision-making algorithm, we were able to provide a set of features that work as a "fingerprint" for this specific pathophysiological condition, even after the acute phase of infection. Since both mass spectrometry and machine learning approaches are well-established and have largely utilized tools within their respective fields, this combination of methods emerges as a distinct alternative for clinical applications, providing a diagnostic screening-faster and more accurate-with improved cost-effectiveness when compared to existing technologies.
Quantifying the advantages and disadvantages of pre-placement genetic screening
Palmer, K; Poole, J; Rawbone, R; Coggon, D
2004-01-01
Background: Tests of genotype may enable workers at unusual risk of future ill-health to be identified. Using them to select for employment, however, entails gains and losses to employers and employees. Ensuring a fair balance between the rights and obligations of each group requires a value judgement, but the advantages and disadvantages to interested parties must first be quantified in a meaningful way. Method and Results: The purposes of pre-employment screening are reviewed, and several simple measures relevant to the separate interests of employers and job applicants proposed—number screened to prevent a single adverse outcome; number excluded to prevent a case; expected incidence of the adverse outcome in those excluded; and preventable fraction. The derivation of these measures is illustrated, and the factors that influence them (the prevalence of the prognostic trait, the relative risk that it carries for an adverse outcome, and the overall incidence of disease) are related algebraically and graphically, to aid judgement on the utility of screening under different circumstances. Conclusions: In sensitive areas such as genetic testing the onus should be on the employer to justify plans for pre-placement screening. Several quantitative measures can be used to inform the ethical and economic debate about screening and to evaluate alternative strategies for prevention. PMID:15090667
NASA Astrophysics Data System (ADS)
Zhang, Ruizhi; Du, Baoli; Chen, Kan; Reece, Mike; Materials Research Insititute Team
With the increasing computational power and reliable databases, high-throughput screening is playing a more and more important role in the search of new thermoelectric materials. Rather than the well established density functional theory (DFT) calculation based methods, we propose an alternative approach to screen for new TE materials: using crystal structural features as 'descriptors'. We show that a non-distorted transition metal sulphide polyhedral network can be a good descriptor for high power factor according to crystal filed theory. By using Cu/S containing compounds as an example, 1600+ Cu/S containing entries in the Inorganic Crystal Structure Database (ICSD) were screened, and of those 84 phases are identified as promising thermoelectric materials. The screening results are validated by both electronic structure calculations and experimental results from the literature. We also fabricated some new compounds to test our screening results. Another advantage of using crystal structure features as descriptors is that we can easily establish structural relationships between the identified phases. Based on this, two material design approaches are discussed: 1) High-pressure synthesis of metastable phase; 2) In-situ 2-phase composites with coherent interface. This work was supported by a Marie Curie International Incoming Fellowship of the European Community Human Potential Program.
Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E
2014-05-01
Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.
NASA Technical Reports Server (NTRS)
Lewis, James P.
1953-01-01
An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.
Khan, Momna; Sultana, Syeda Seema; Jabeen, Nigar; Arain, Uzma; Khans, Salma
2015-02-01
To determine the diagnostic accuracy of visual inspection of cervix using 3% acetic acid as a screening test for early detection of cervical cancer taking histopathology as the gold standard. The cross-sectional study was conducted at Civil Hospital Karachi from July 1 to December 31, 2012 and comprised all sexually active women aged 19-60 years. During speculum examination 3% acetic acid was applied over the cervix with the help of cotton swab. The observations were noted as positive or negative on visual inspection of the cervix after acetic acid application according to acetowhite changes. Colposcopy-guided cervical biopsy was done in patients with positive or abnormal looking cervix. Colposcopic-directed biopsy was taken as the gold standard to assess visual inspection readings. SPSS 17 was used for statistical analysis. There were 500 subjects with a mean age of 35.74 ± 9.64 years. Sensitivity, specifically, positive predicted value, negative predicted value of visual inspection of the cervix after acetic acid application was 93.5%, 95.8%, 76.3%, 99%, and the diagnostic accuracy was 95.6%. Visual inspection of the cervix after acetic acid application is an effective method of detecting pre-invasive phase of cervical cancer and a good alternative to cytological screening for cervical cancer in resource-poor setting like Pakistan and can reduce maternal morbidity and mortality.
Couturier, Jean‐Luc; Kokossis, Antonis; Dubois, Jean‐Luc
2016-01-01
Abstract Biorefineries offer a promising alternative to fossil‐based processing industries and have undergone rapid development in recent years. Limited financial resources and stringent company budgets necessitate quick capital estimation of pioneering biorefinery projects at the early stages of their conception to screen process alternatives, decide on project viability, and allocate resources to the most promising cases. Biorefineries are capital‐intensive projects that involve state‐of‐the‐art technologies for which there is no prior experience or sufficient historical data. This work reviews existing rapid cost estimation practices, which can be used by researchers with no previous cost estimating experience. It also comprises a comparative study of six cost methods on three well‐documented biorefinery processes to evaluate their accuracy and precision. The results illustrate discrepancies among the methods because their extrapolation on biorefinery data often violates inherent assumptions. This study recommends the most appropriate rapid cost methods and urges the development of an improved early‐stage capital cost estimation tool suitable for biorefinery processes. PMID:27484398
Iles, Ray K; Shahpari, Maryam E; Cuckle, Howard; Butler, Stephen A
2015-01-01
The established methods of antenatal screening for Down syndrome are based on immunoassay for a panel of maternal serum biomarkers together with ultrasound measures. Recently, genetic analysis of maternal plasma cell free (cf) DNA has begun to be used but has a number of limitations including excessive turn-around time and cost. We aimed to develop an alternative method based on urinalysis that is simple, affordable and accurate. 101 maternal urine samples sampled at 12-17 weeks gestation were taken from an archival collection of 2567 spot urines collected from women attending a prenatal screening clinic. 18 pregnancies in this set subsequently proved to be Down pregnancies. Samples were either neat urine or diluted between 10 to 1000 fold in dH2O and subjected to matrix assisted laser desorption ionization (MALDI), time of flight (ToF) mass spectrometry (MS). Data profiles were examined in the region 6,000 to 14,000 m/z. Spectral data was normalised and quantitative characteristics of the profile were compared between Down and controls. In Down cases there were additional spectral profile peaks at 11,000-12,000 m/z and a corresponding reduction in intensity at 6,000-8,000 m/z. The ratio of the normalised values at these two ranges completely separated the 8 Down syndrome from the 39 controls at 12-14 weeks. Discrimination was poorer at 15-17 weeks where 3 of the 10 Down syndrome cases had values within the normal range. Direct MALDI ToF mass spectral profiling of maternal urinary has the potential for an affordable, simple, accurate and rapid alternative to current Down syndrome screening protocols.
High-throughput Titration of Luciferase-expressing Recombinant Viruses
Garcia, Vanessa; Krishnan, Ramya; Davis, Colin; Batenchuk, Cory; Le Boeuf, Fabrice; Abdelbary, Hesham; Diallo, Jean-Simon
2014-01-01
Standard plaque assays to determine infectious viral titers can be time consuming, are not amenable to a high volume of samples, and cannot be done with viruses that do not form plaques. As an alternative to plaque assays, we have developed a high-throughput titration method that allows for the simultaneous titration of a high volume of samples in a single day. This approach involves infection of the samples with a Firefly luciferase tagged virus, transfer of the infected samples onto an appropriate permissive cell line, subsequent addition of luciferin, reading of plates in order to obtain luminescence readings, and finally the conversion from luminescence to viral titers. The assessment of cytotoxicity using a metabolic viability dye can be easily incorporated in the workflow in parallel and provide valuable information in the context of a drug screen. This technique provides a reliable, high-throughput method to determine viral titers as an alternative to a standard plaque assay. PMID:25285536
2011-01-01
Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473
Radon and lung cancer: a cost-effectiveness analysis.
Ford, E S; Kelly, A E; Teutsch, S M; Thacker, S B; Garbe, P L
1999-01-01
OBJECTIVES: This study examined the cost-effectiveness of general and targeted strategies for residential radon testing and mitigation in the United States. METHODS: A decision-tree model was used to perform a cost-effectiveness analysis of preventing radon-associated deaths from lung cancer. RESULTS: For a radon threshold of 4 pCi/L, the estimated costs to prevent 1 lung cancer death are about $3 million (154 lung cancer deaths prevented), or $480,000 per life-year saved, based on universal radon screening and mitigation, and about $2 million (104 lung cancer deaths prevented), or $330,000 per life-year saved, if testing and mitigation are confined to geographic areas at high risk for radon exposure. For mitigation undertaken after a single screening test and after a second confirmatory test, the estimated costs are about $920,000 and $520,000, respectively, to prevent a lung cancer death with universal screening and $130,000 and $80,000 per life-year for high risk screening. The numbers of preventable lung cancer deaths are 811 and 527 for universal and targeted approaches, respectively. CONCLUSIONS: These data suggest possible alternatives to current recommendations. PMID:10076484
Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram
2014-10-17
Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.
Ulph, Fiona; Wright, Stuart; Dharni, Nimarta; Payne, Katherine; Bennett, Rebecca; Roberts, Stephen; Walshe, Kieran; Lavender, Tina
2017-10-01
Participation in the UK Newborn Bloodspot Screening Programme (NBSP) requires parental consent but concerns exist about whether or not this happens in practice and the best methods and timing to obtain consent at reasonable cost. To collate all possible modes of prescreening communication and consent for newborn (neonatal) screening (NBS); examine midwives', screening professionals' and users' views about the feasibility, efficiency and impact on understanding of each; measure midwives' and parents' preferences for information provision; and identify key drivers of cost-effectiveness for alternative modes of information provision. Six study designs were used: (1) realist review - to generate alternative communication and consent models; (2) qualitative interviews with parents and health professionals - to examine the implications of current practice for understanding and views on alternative models; (3) survey and observation of midwives - to establish current costs; (4) stated preference surveys with midwives, parents and potential future parents - to establish preferences for information provision; (5) economic analysis - to identify cost-effectiveness drivers of alternative models; and (6) stakeholder validation focus groups and interviews - to examine the acceptability, views and broader impact of alternative communication and consent models. Providers and users of NBS in England. Study 2: 45 parents and 37 health professionals; study 3: 22 midwives and eight observations; study 4: 705 adults aged 18-45 years and 134 midwives; and study 6: 12 health-care professionals and five parents. The realist review identified low parental knowledge and evidence of coercive consent practices. Interview, focus group and stated preference data suggested a preference for full information, with some valuing this more than choice. Health professionals preferred informed choice models but parents and health professionals queried whether or not current consent was fully informed. Barriers to using leaflets effectively were highlighted. All studies indicated that a 'personalised' approach to NBS communication, allowing parents to select the mode and level of information suited to their learning needs, could have added value. A personalised approach should rely on midwife communication and should occur in the third trimester. Overall awareness was identified as requiring improvement. Starting NBS communication by alerting parents that they have a choice to make and telling them that samples could be stored are both likely to enhance engagement. The methods of information provision and maternal anxiety causing additional visits to health-care professionals were the drivers of relative cost-effectiveness. Lack of data to populate an economic analysis, confirmed by value of information analysis, indicated a need for further research. There are some limitations with regard to the range of participants used in studies 2 and 3 and so caution should be exercised when interpreting some of the results. This project highlighted the importance of focusing on information receipt and identified key communication barriers. Health professionals strongly preferred informed consent, which parents endorsed if they were made aware of sample storage. Uniform models of information provision were perceived as ineffective. A choice of information provision was supported by health professionals and parents, which both enhances cost-effectiveness and improves engagement, understanding and the validity of consent. Remaining uncertainties suggest that more research is needed before new communication modes are introduced into practice. Future research should measure the impact of the suggested practice changes (informing in third trimester, information toolkits, changed role of midwife). Current Controlled Trials ISRCTN70227207. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 21, No. 55. See the NIHR Journals Library website for further project information.
Remediation alternatives for low-level herbicide contaminated groundwater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conger, R.M.
In early 1995, an evaluation of alternatives for remediation of a shallow groundwater plume containing low-levels of an organic herbicide was conducted at BASF Corporation, a petrochemical facility located in Ascension Parish, Louisiana. The contaminated site is located on an undeveloped portion of property within 1/4 mile of the east bank of the Mississippi River near the community of Geismar. Environmental assessment data indicated that about two acres of the thirty acre site had been contaminated from past waste management practices with the herbicide bentazon. Shallow soils and groundwater between 5 to 15 feet in depth were affected. Maximum concentrationsmore » of bentazon in groundwater were less than seven parts per million. To identify potentially feasible remediation alternatives, the environmental assessment data, available research, and cost effectiveness were reviewed. After consideration of a preliminary list of alternatives, only two potentially feasible alternatives could be identified. Groundwater pumping, the most commonly used remediation alternative, followed by carbon adsorption treatment was identified as was a new innovative alternative known as vegetative transpiration. This alternative relies on the natural transpiration processes of vegetation to bioremediate organic contaminants. Advantages identified during screening suggest that the transpiration method could be the best remediation alternative to address both economic and environmental factors. An experiment to test critical factors of the vegetatived transpiration alternative with bentazon was recommended before a final decision on feasibility can be made.« less
Programmatic Cost Evaluation of Nontargeted Opt-Out Rapid HIV Screening in the Emergency Department
Haukoos, Jason S.; Campbell, Jonathan D.; Conroy, Amy A.; Hopkins, Emily; Bucossi, Meggan M.; Sasson, Comilla; Al-Tayyib, Alia A.; Thrun, Mark W.
2013-01-01
Background The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. Methods This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. Results During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%–0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%–4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Conclusions Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED. PMID:24391706
ENVIRONMENTAL LIFE CYCLE ASSESSMENT OF GASOLINE ALTERNATIVES: MTBE AND ETHANOL ADDITIVES
Currently, the U.S. is considering options for additives to reformulated gasoline. To inform this debate the U.S. EPA's Office of Research and Development is conducting a screening life cycle assessment (LCA) of three gasoline alternatives. These alternatives include gasoline w...
NASA Technical Reports Server (NTRS)
La Bel, Kenneth A.; Sampson, Michael J.
2016-01-01
As the space business rapidly evolves to accommodate a lower cost model of development and operation via concepts such as commercial space and small spacecraft (aka, CubeSats), traditional EEE parts screening and qualification methods are being scrutinized under a risk-reward trade space. In this presentation, two basic concepts will be the overarching theme: 1) The movement from complete risk aversion EEE parts methods to managing and/or accepting risk via alternate approaches; and, 2) A discussion of over-design focusing on both electrical design performance and bounding margins.
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Sampson, Michael J.
2016-01-01
As the space business rapidly evolves to accommodate a lower cost model of development and operation via concepts such as commercial space and small spacecraft (aka, CubeSats), traditional EEE parts screening and qualification methods are being scrutinized under a risk-reward trade space. In this presentation, two basic concepts will be the overarching theme: 1) The movement from complete risk aversion EEE parts methods to managing and or accepting risk via alternate approaches; and, 2) A discussion of over-design focusing on both electrical design performance and bounding margins.
[Blood sampling using "dried blood spot": a clinical biology revolution underway?].
Hirtz, Christophe; Lehmann, Sylvain
2015-01-01
Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.
Tewfik, Ihab
2008-01-01
2-Alkylcyclobutanones (cyclobutanones) are accepted as chemical markers for irradiated foods containing lipid. However, current extraction procedures (Soxhlet-florisil chromatography) for the isolation of these markers involve a long and tedious clean-up regime prior to gas chromatography-mass spectrophotometry identification. This paper outlines an alternative isolation and clean-up method for the extraction of cyclobutanones in irradiated Camembert cheese. The newly developed direct solvent extraction method enables the efficient screening of large numbers of food samples and is not as resource intensive as the BS EN 1785:1997 method. Direct solvent extraction appears to be a simple, robust method and has the added advantage of a considerably shorter extraction time for the analysis of foods containing lipid.
Urinary tract infections in women with urogynaecological symptoms.
Lakeman, Marielle M E; Roovers, Jan-Paul W R
2016-02-01
Urinary tract infections are common in the field of urogynaecology. Women with persistent urinary symptoms seem more likely to have bacteriuria despite negative cultures. In this review, we will give an overview of the recent insights on the relationship between urinary tract infection and persistent urinary symptoms and possible new therapeutic options. Recently published articles evaluated the prevalence of low-count bacteriuria (≥10 CFU/ml) or intracellular bacterial communities in women with overactive bladder symptoms (OAB). Differences in urinary microbioma observed in women with and without OAB symptoms were evaluated. In the light of these findings, current screening strategies were discussed and alternative screening methods for bacteriuria developed. Low-count bacteriuria (≥10 CFU/ml) seems to be more prevalent in women with OAB. Also intracellular bacterial communities are more commonly detected in these women. The microbioma found in women with urinary symptoms appeared to differ from healthy controls. The current screening methods might be insufficient as they are targeted at detecting uropathogenic Escherichia coli, mostly using a detection threshold of at least 10 CFU/ml and failing to detect intracellular bacterial communities. Studies evaluating the efficacy of treating women with low-count bacteriuria are limited but promising.
Predicting speech intelligibility in noise for hearing-critical jobs
NASA Astrophysics Data System (ADS)
Soli, Sigfrid D.; Laroche, Chantal; Giguere, Christian
2003-10-01
Many jobs require auditory abilities such as speech communication, sound localization, and sound detection. An employee for whom these abilities are impaired may constitute a safety risk for himself or herself, for fellow workers, and possibly for the general public. A number of methods have been used to predict these abilities from diagnostic measures of hearing (e.g., the pure-tone audiogram); however, these methods have not proved to be sufficiently accurate for predicting performance in the noise environments where hearing-critical jobs are performed. We have taken an alternative and potentially more accurate approach. A direct measure of speech intelligibility in noise, the Hearing in Noise Test (HINT), is instead used to screen individuals. The screening criteria are validated by establishing the empirical relationship between the HINT score and the auditory abilities of the individual, as measured in laboratory recreations of real-world workplace noise environments. The psychometric properties of the HINT enable screening of individuals with an acceptable amount of error. In this presentation, we will describe the predictive model and report the results of field measurements and laboratory studies used to provide empirical validation of the model. [Work supported by Fisheries and Oceans Canada.
Rapid DNA extraction from dried blood spots on filter paper: potential applications in biobanking.
Choi, Eun-Hye; Lee, Sang Kwang; Ihm, Chunhwa; Sohn, Young-Hak
2014-12-01
Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. The purpose of this study was to compare the quality, purity, and quantity of DNA isolated from frozen blood samples and DBSs. We optimized a method for extraction and estimation of DNA from blood spots dried on filter paper (3-mm FTA card). A single DBS containing 40 μL blood was used. DNA was efficiently extracted in phosphate-buffered saline (PBS) or Tris-EDTA (TE) buffer by incubation at 37°C overnight. DNA was stable in DBSs that were stored at room temperature or frozen. The housekeeping genes GAPDH and beta-actin were used as positive standards for polymerase chain reaction (PCR) validation of general diagnostic screening. Our simple and convenient DBS storage and extraction methods are suitable for diagnostic screening by using very small volumes of blood collected on filter paper, and can be used in biobanks for blood sample storage.
NASA Astrophysics Data System (ADS)
Guo, Baoshan; Lei, Cheng; Ito, Takuro; Yaxiaer, Yalikun; Kobayashi, Hirofumi; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke
2017-02-01
The development of reliable, sustainable, and economical sources of alternative fuels is an important, but challenging goal for the world. As an alternative to liquid fossil fuels, microalgal biofuel is expected to play a key role in reducing the detrimental effects of global warming since microalgae absorb atmospheric CO2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid contents and fail to characterize a diverse population of microalgal cells with single-cell resolution in a noninvasive and interference-free manner. Here we demonstrate high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy. In particular, we use Euglena gracilis - an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement) within lipid droplets. Our optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch phase-contrast microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase contents of every single cell at a high throughput of 10,000 cells/s. We characterize heterogeneous populations of E. gracilis cells under two different culture conditions to evaluate their lipid production efficiency. Our method holds promise as an effective analytical tool for microalgaebased biofuel production.
Implementation of Alternative Test Strategies for the Safety Assessment of Engineered Nanomaterials
Nel, Andre
2014-01-01
Nanotechnology introduces a new field that requires novel approaches and methods for hazard and risk assessment. For an appropriate scientific platform for safety assessment, nanoscale properties and functions of engineered nanomaterials (ENMs), including how the physicochemical properties of the materials related to mechanisms of injury at the nano-bio interface, must be considered. Moreover, this rapidly advancing new field requires novel test strategies that allow multiple toxicants to be screened in robust, mechanism-based assays in which the bulk of the investigation can be carried out at the cellular and biomolecular level whilst maintaining limited animal use and is based on the contribution of toxicological pathways to the pathophysiology of disease. First, a predictive toxicological approach for the safety assessment of ENMs will be discussed against the background of a ‘21st-century vision’ for using alternative test strategies (ATSs) to perform toxicological assessment of large numbers of untested chemicals, thereby reducing a backlog that could otherwise become a problem for nanotechnology. An ATS is defined here as an alternative/reduction alternative to traditional animal testing. Secondly, the approach of selecting pathways of toxicity to screen for the pulmonary hazard potential of carbon nanotubes and metal oxides will be discussed, as well as how to use these pathways to perform high-content or high-throughput testing and how the data can be used for hazard ranking, risk assessment, regulatory decision-making and ‘safer-by-design’ strategies. Finally, the utility and disadvantages of this predictive toxicological approach to ENM safety assessment, and how it can assist the 21st- century vision, will be addressed PMID:23879741
Hwang, Jessica P; Roundtree, Aimee K; Engebretson, Joan C; Suarez-Almazor, Maria E
2010-03-01
Physicians can play a significant role in helping to decrease the hepatitis B virus (HBV) burden among Asian Americans. Few studies have described knowledge and practice patterns in the medical community among different provider types regarding HBV and liver cancer. Our study explores the HBV beliefs, attitudes and practice patterns of medical providers serving Asian American communities. We conducted three focus groups with primary care providers, liver specialists, and other providers predominantly serving Asian American community. We asked about practices and barriers to appropriate medical care and outreach. We moderated three focus groups with 23 participants, 18 of whom completed and returned demographic surveys. Twelve were of Asian ethnicity and 13 spoke English as a second language. Only eight screened at least half of their patients, most (72%) using the hepatitis B surface antigen test. We used grounded theory methods to analyze focus group transcripts. Participants frequently discussed cultural and financial barriers to hepatitis care. They admitted reluctance to screen for HBV because patients might be unwilling or unable to afford treatment. Cultural differences were discussed most by primary care providers; best methods of outreach were discussed most by liver specialists; and alternative medicine was discussed most by acupuncturists and other providers. More resources are needed to lower financial barriers complicating HBV care and encourage providing guideline-recommended screenings. Other providers can help promote HBV screening and increase community and cultural awareness.
Predictive validity of curriculum-based measurement and teacher ratings of academic achievement.
Kettler, Ryan J; Albers, Craig A
2013-08-01
Two alternative universal screening approaches to identify students with early learning difficulties were examined, along with a combination of these approaches. These approaches, consisting of (a) curriculum-based measurement (CBM) and (b) teacher ratings using Performance Screening Guides (PSGs), served as predictors of achievement tests in reading and mathematics. Participants included 413 students in grades 1, 2, and 3 in Tennessee (n=118) and Wisconsin (n=295) who were divided into six subsamples defined by grade and state. Reading and mathematics achievement tests with established psychometric properties were used as criteria within a concurrent and predictive validity framework. Across both achievement areas, CBM probes shared more variance with criterion measures than did teacher ratings, although teacher ratings added incremental validity among most subsamples. PSGs tended to be more accurate for identifying students in need of assistance at a 1-month interval, whereas CBM probes were more accurate at a 6-month interval. Teachers indicated that (a) false negatives are more problematic than are false positives, (b) both screening methods are useful for identifying early learning difficulties, and (c) both screening methods are useful for identifying students in need of interventions. Collectively, these findings suggest that the two types of measures, when used together, yield valuable information about students who need assistance in reading and mathematics. Copyright © 2013 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Programmatic cost evaluation of nontargeted opt-out rapid HIV screening in the emergency department.
Haukoos, Jason S; Campbell, Jonathan D; Conroy, Amy A; Hopkins, Emily; Bucossi, Meggan M; Sasson, Comilla; Al-Tayyib, Alia A; Thrun, Mark W
2013-01-01
The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%-0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%-4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED.
Validation of an ELISA Synthetic Cannabinoids Urine Assay
Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.
2015-01-01
Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046
Kogot, Joshua M.; Zhang, Yanting; Moore, Stephen J.; Pagano, Paul; Stratis-Cullum, Dimitra N.; Chang-Yen, David; Turewicz, Marek; Pellegrino, Paul M.; de Fusco, Andre; Soh, H. Tom; Stagliano, Nancy E.
2011-01-01
Bacterial surface peptide display has gained popularity as a method of affinity reagent generation for a wide variety of applications ranging from drug discovery to pathogen detection. In order to isolate the bacterial clones that express peptides with high affinities to the target molecule, multiple rounds of manual magnetic activated cell sorting (MACS) followed by multiple rounds of fluorescence activated cell sorting (FACS) are conventionally used. Although such manual methods are effective, alternative means of library screening which improve the reproducibility, reduce the cost, reduce cross contamination, and minimize exposure to hazardous target materials are highly desired for practical application. Toward this end, we report the first semi-automated system demonstrating the potential for screening bacterially displayed peptides using disposable microfluidic cartridges. The Micro-Magnetic Separation platform (MMS) is capable of screening a bacterial library containing 3×1010 members in 15 minutes and requires minimal operator training. Using this system, we report the isolation of twenty-four distinct peptide ligands that bind to the protective antigen (PA) of Bacilus anthracis in three rounds of selection. A consensus motif WXCFTC was found using the MMS and was also found in one of the PA binders isolated by the conventional MACS/FACS approach. We compared MMS and MACS rare cell recovery over cell populations ranging from 0.1% to 0.0000001% and found that both magnetic sorting methods could recover cells down to 0.0000001% initial cell population, with the MMS having overall lower standard deviation of cell recovery. We believe the MMS system offers a compelling approach towards highly efficient, semi-automated screening of molecular libraries that is at least equal to manual magnetic sorting methods and produced, for the first time, 15-mer peptide binders to PA protein that exhibit better affinity and specificity than peptides isolated using conventional MACS/FACS. PMID:22140433
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Arnold, Suzanne V; Lipska, Kasia J; Inzucchi, Silvio E; Li, Yan; Jones, Philip G; McGuire, Darren K; Goyal, Abhinav; Stolker, Joshua M; Lind, Marcus; Spertus, John A; Kosiborod, Mikhail
2014-01-01
Incident diabetes mellitus (DM) is important to recognize in patients with acute myocardial infarction (AMI). To develop an efficient screening strategy, we explored the use of random plasma glucose (RPG) at admission and fasting plasma glucose (FPG) to select patients with AMI for glycosylated hemoglobin (HbA1c) testing. Prospective registry of 1574 patients with AMI not taking glucose-lowering medication from 24 US hospitals. All patients had HbA1c measured at a core laboratory and admission RPG and ≥2 FPGs recorded during hospitalization. We examined potential combinations of RPG and FPG and compared these with HbA1c≥6.5%-considered the gold standard for DM diagnosis in these analyses. An RPG>140 mg/dL or FPG≥126 mg/dL had high sensitivity for DM diagnosis. Combining these into a screening protocol (if admission RPG>140, check HbA1c; or if FPG≥126 on a subsequent day, check HbA1c) led to HbA1c testing in 50% of patients and identified 86% with incident DM (number needed to screen (NNS)=3.3 to identify 1 case of DM; vs NNS=5.6 with universal HbA1c screening). Alternatively, using an RPG>180 led to HbA1c testing in 40% of patients with AMI and identified 82% of DM (NNS=2.7). We have established two potential selective screening methods for DM in the setting of AMI that could identify the vast majority of incident DM by targeted screening of 40-50% of patients with AMI with HbA1c testing. Using these methods may efficiently identify patients with AMI with DM so that appropriate education and treatment can be promptly initiated.
Shrestha, Smita; Dhakal, Prativa
2017-03-01
Objective: To find out the knowledge, attitude and practice regarding cervical cancer screening among women. Materials and methods: A descriptive cross-sectional study design was used to collect data from 96 women. Each woman was selected alternately from Gynae Out-Patient Department of Teaching Hospital. Data was collected by using semi-structured interview schedule to find out knowledge and practice and Likert scale to find out the attitude regarding cervical cancer screening. Data was analyzed by using SPSS version 20.0 and interpreted in terms of descriptive and inferential statistics. Results: Out of 96 women, mean age was 38.83 ± 6.57 and 90.6% respondents followed Hinduism. More than three fourth (85.4%) were literate and 59.4% were housewife. Only 9.4% were involved in cervical cancer prevention and screening awareness programme and 2.1% had family history of cervical cancer. As per the findings, only 34.4% and 27.8% had adequate knowledge and practice respectively whereas cent percent women had favorable attitude. Only education level of women was statistically significant with level of knowledge regarding cervical cancer screening (p = 0.041). There was strong negative correlation between knowledge score and practice score regarding cervical cancer screening among women (r = -0.194). Conclusion: Considerable proportions of women have inadequate knowledge and practice regarding cervical cancer screening. Therefore cervical cancer screening health camps and awareness program should be conducted at community level for women to increase the level of knowledge and practice regarding cervical cancer screening.
Economic Analysis of Screening Strategies for Rupture of Silicone Gel Breast Implants
Chung, Kevin C.; Malay, Sunitha; Shauver, Melissa J.; Kim, H. Myra
2012-01-01
Background In 2006, the U.S. Food and Drug Administration (FDA) recommended screening of all women with silicone gel breast implants with magnetic resonance imaging (MRI) three years after implantation and every two years thereafter to assess their integrity. The cost for these serial examinations over the lifetime of the breast implants is an added burden to insurance payers and to women. We perform an economic analysis to determine the most optimal screening strategies by considering the diagnostic accuracy of the screening tests, the costs of the tests and subsequent implant removal. Methods We determined aggregate/pooled values for sensitivity and specificity of the screening tests ultrasound (US) and MRI in detecting silicone breast implant ruptures from the data obtained from published literature. We compiled costs, based on Medicare reimbursements for 2011, for the following elements: imaging modalities, anesthesia and 3 surgical treatment options for detected ruptures. We used decision tree to compare three alternate screening strategies of US only, MRI only and US followed by MRI in asymptomatic and symptomatic women. Results The cost per rupture of screening and management of rupture with US in asymptomatic women was $1,090, whereas in symptomatic women it was $1,622. Similar cost for MRI in asymptomatic women was $2,067, whereas in symptomatic women it was $2,143. Similar cost for US followed by MRI in asymptomatic women was $637, whereas in symptomatic women it was $2,908. Conclusion Screening with US followed by MRI was optimal for asymptomatic women and screening with US was optimal for symptomatic women. PMID:22743887
Shrestha, Smita; Dhakal, Prativa
2017-01-01
Objective: To find out the knowledge, attitude and practice regarding cervical cancer screening among women. Materials and methods: A descriptive cross-sectional study design was used to collect data from 96 women. Each woman was selected alternately from Gynae Out-Patient Department of Teaching Hospital. Data was collected by using semi-structured interview schedule to find out knowledge and practice and Likert scale to find out the attitude regarding cervical cancer screening. Data was analyzed by using SPSS version 20.0 and interpreted in terms of descriptive and inferential statistics. Results: Out of 96 women, mean age was 38.83 ± 6.57 and 90.6% respondents followed Hinduism. More than three fourth (85.4%) were literate and 59.4% were housewife. Only 9.4% were involved in cervical cancer prevention and screening awareness programme and 2.1% had family history of cervical cancer. As per the findings, only 34.4% and 27.8% had adequate knowledge and practice respectively whereas cent percent women had favorable attitude. Only education level of women was statistically significant with level of knowledge regarding cervical cancer screening (p = 0.041). There was strong negative correlation between knowledge score and practice score regarding cervical cancer screening among women (r = -0.194). Conclusion: Considerable proportions of women have inadequate knowledge and practice regarding cervical cancer screening. Therefore cervical cancer screening health camps and awareness program should be conducted at community level for women to increase the level of knowledge and practice regarding cervical cancer screening. PMID:29114264
Campbell, Christine; Kafwafwa, Savel; Brown, Hilary; Walker, Graeme; Madetsa, Belito; Deeny, Miriam; Kabota, Beatrice; Morton, David; Ter Haar, Reynier; Grant, Liz; Cubie, Heather A
2016-08-15
The incidence of cervical cancer in Malawi is the highest in the world and projected to increase in the absence of interventions. Although government policy supports screening using visual inspection with acetic acid (VIA), screening provision is limited due to lack of infrastructure, trained personnel, and the cost and availability of gas for cryotherapy. Recently, thermo-coagulation has been acknowledged as a safe and acceptable procedure suitable for low-resource settings. We introduced thermo-coagulation for treatment of VIA-positive lesions as an alternative to cryotherapy within a cervical screening service based on VIA, coupled with appropriate, sustainable pathways of care for women with high-grade lesions and cancers. Detailed planning was undertaken for VIA clinics, and approvals were obtained from the Ministry of Health, Regional and Village Chiefs. Educational resources were developed. Thermo-coagulators were introduced into hospital and health centre settings, with theoretical and practical training in safe use and maintenance of equipment. A total of 7,088 previously unscreened women attended VIA clinics between October 2013 and March 2015. Screening clinics were held daily in the hospital and weekly in the health centres. Overall, VIA positivity was 6.1%. Almost 90% received same day treatment in the hospital setting, and 3- to 6-month cure rates of more than 90% are observed. Thermo-coagulation proved feasible and acceptable in this setting. Effective implementation requires comprehensive training and provider support, ongoing competency assessment, quality assurance and improvement audit. Thermo-coagulation offers an effective alternative to cryotherapy and encouraged VIA screening of many more women. © 2016 The Authors International Journal of Cancer published by John Wiley & Sons Ltd on behalf of UICC.
Archfield, Stacey A.; LeBlanc, Denis R.
2005-01-01
To evaluate diffusion sampling as an alternative method to monitor volatile organic compound (VOC) concentrations in ground water, concentrations in samples collected by traditional pumped-sampling methods were compared to concentrations in samples collected by diffusion-sampling methods for 89 monitoring wells at or near the Massachusetts Military Reservation, Cape Cod. Samples were analyzed for 36 VOCs. There was no substantial difference between the utility of diffusion and pumped samples to detect the presence or absence of a VOC. In wells where VOCs were detected, diffusion-sample concentrations of tetrachloroethene (PCE) and trichloroethene (TCE) were significantly lower than pumped-sample concentrations. Because PCE and TCE concentrations detected in the wells dominated the calculation of many of the total VOC concentrations, when VOC concentrations were summed and compared by sampling method, visual inspection also showed a downward concentration bias in the diffusion-sample concentration. The degree to which pumped- and diffusion-sample concentrations agreed was not a result of variability inherent within the sampling methods or the diffusion process itself. A comparison of the degree of agreement in the results from the two methods to 13 quantifiable characteristics external to the sampling methods offered only well-screen length as being related to the degree of agreement between the methods; however, there is also evidence to indicate that the flushing rate of water through the well screen affected the agreement between the sampling methods. Despite poor agreement between the concentrations obtained by the two methods at some wells, the degree to which the concentrations agree at a given well is repeatable. A one-time, well-bywell comparison between diffusion- and pumped-sampling methods could determine which wells are good candidates for the use of diffusion samplers. For wells with good method agreement, the diffusion-sampling method is a time-saving and cost-effective alternative to pumped-sampling methods in a long-term monitoring program, such as at the Massachusetts Military Reservation.
Jacobson, Sheldon H; Yu, Ge; Jokela, Janet A
2016-07-01
This paper provides an alternative policy for Ebola entry screening at airports in the United States. This alternative policy considers a social contact tracing (SCT) risk level, in addition to the current health risk level used by the CDC. The performances of both policies are compared based on the scenarios that occur and the expected cost associated with implementing such policies. Sensitivity analysis is performed to identify conditions under which one policy dominates the other policy. This analysis takes into account that the alternative policy requires additional data collection, which is balanced by a more cost-effective allocation of resources. Copyright © 2016 Elsevier Inc. All rights reserved.
Sullivan, Harold C; Fisher, Kevin E; Hoffa, Anne L; Wang, Jason; Saxe, Debra; Siddiqui, Momin T; Cohen, Cynthia
2015-04-01
Among the mutations described in non-small cell lung carcinoma is a rearrangement resulting from an inversion within chromosome 2p leading to the formation of a fusion gene, echinoderm microtubule-associated protein-like 4-anaplastic lymphoma kinase (EML4-ALK). Fluorescence in situ hybridization (FISH) is the gold standard for the detection of ALK gene rearrangements. However, molecular methods are not readily available in all pathology laboratories. Immunohistochemistry (IHC) using an antibody directed against the EML4-ALK fusion protein provides a widely available alternative method of detection. We assessed whether IHC is a comparable and cost-effective alternative to FISH analysis for the detection of ALK gene rearrangements. A total of 110 non-small cell lung carcinoma cases (63 surgical/biopsy and 47 cytology specimens), previously tested for ALK gene rearrangements by FISH [7 (6.4%) positive for the rearrangement], were probed for the EML4-ALK fusion protein using a monoclonal EML4-ALK antibody, clone 5A4. Cells were considered to stain positive for ALK if >5% of cells showed cytoplasmic staining of at least grade 1 intensity (scale: 0 to 3). A cost analysis was performed using ALK IHC as a screening test. The sensitivity and specificity of the EML4-ALK IHC stain compared with ALK FISH analysis were 100% and 96%, respectively. All 7 FISH-positive cases stained positive by IHC, whereas 4 FISH-negative cases demonstrated positive staining. One of the 4 FISH-negative, IHC-positive cases harbored an EML4-ALK rearrangement by RT-PCR yielding 3 false-positive results overall. The κ agreement between IHC and FISH methods is 0.76 (substantial/excellent). The potential savings of implementing the ALK IHC as a screening method would be $10,418.21. Sensitivity of the EML4-ALK IHC stain is excellent (100%) but due to its suboptimal specificity, IHC cannot reliably supplant FISH analysis for the detection of ALK gene rearrangements. IHC shows promise as a screening tool to prevent unnecessary costly FISH analysis.
Comparison of Screen Sizes When Using Video Prompting to Teach Adolescents with Autism
ERIC Educational Resources Information Center
Bennett, Kyle D.; Gutierrez, Anibal, Jr.; Loughrey, Tara O.
2016-01-01
Recently, researchers have compared the effectiveness of video-based instruction (VBI), particularly video modeling, when using smaller versus larger screen sizes with positive, but mixed results. Using an adapted alternating treatments design, we compared two different screen sizes (i.e., iPhone 5 versus iPad 2) using video prompting as the VBI…
Lee, Jaeyoung; Yasmin, Shamsunnahar; Eluru, Naveen; Abdel-Aty, Mohamed; Cai, Qing
2018-02-01
In traffic safety literature, crash frequency variables are analyzed using univariate count models or multivariate count models. In this study, we propose an alternative approach to modeling multiple crash frequency dependent variables. Instead of modeling the frequency of crashes we propose to analyze the proportion of crashes by vehicle type. A flexible mixed multinomial logit fractional split model is employed for analyzing the proportions of crashes by vehicle type at the macro-level. In this model, the proportion allocated to an alternative is probabilistically determined based on the alternative propensity as well as the propensity of all other alternatives. Thus, exogenous variables directly affect all alternatives. The approach is well suited to accommodate for large number of alternatives without a sizable increase in computational burden. The model was estimated using crash data at Traffic Analysis Zone (TAZ) level from Florida. The modeling results clearly illustrate the applicability of the proposed framework for crash proportion analysis. Further, the Excess Predicted Proportion (EPP)-a screening performance measure analogous to Highway Safety Manual (HSM), Excess Predicted Average Crash Frequency is proposed for hot zone identification. Using EPP, a statewide screening exercise by the various vehicle types considered in our analysis was undertaken. The screening results revealed that the spatial pattern of hot zones is substantially different across the various vehicle types considered. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gladysz, Rafaela; Cleenewerck, Matthias; Joossens, Jurgen; Lambeir, Anne-Marie; Augustyns, Koen; Van der Veken, Pieter
2014-10-13
Fragment-based drug discovery (FBDD) has evolved into an established approach for "hit" identification. Typically, most applications of FBDD depend on specialised cost- and time-intensive biophysical techniques. The substrate activity screening (SAS) approach has been proposed as a relatively cheap and straightforward alternative for identification of fragments for enzyme inhibitors. We have investigated SAS for the discovery of inhibitors of oncology target urokinase (uPA). Although our results support the key hypotheses of SAS, we also encountered a number of unreported limitations. In response, we propose an efficient modified methodology: "MSAS" (modified substrate activity screening). MSAS circumvents the limitations of SAS and broadens its scope by providing additional fragments and more coherent SAR data. As well as presenting and validating MSAS, this study expands existing SAR knowledge for the S1 pocket of uPA and reports new reversible and irreversible uPA inhibitor scaffolds. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zeisser-Labouèbe, Magali; Delie, Florence; Gurny, Robert; Lange, Norbert
2009-02-01
In urology, fluorescence-based imaging methods have been proven to significantly improve the detection of small, barely visible tumors and reduce the recurrence rate. Under ethical and economical pressure, new effective screening systems have to be developed to exploit and assess novel strategies for fluorescence photodetection in other areas. For this purpose, the chorioallantoic membrane (CAM) of the developing chick embryo is an attractive alternative model to the mammalian models. Hypericin encapsulated into nanoparticles for the photodetection of ovarian metastases was evaluated in the CAM model with respect to vascular extravazation and tumor targeting and compared with free drug following intravenous administration. To validate the CAM model as a valuable screening system for photodetection of cancer, we drew a comparison with results obtained on a conventional rodent model. Rodent and CAM models led to the same conclusion regarding the benefits of nanoencapsulation to improve selective accumulation of drug in ovarian micrometastases.
Identification of a New Zinc Binding Chemotype by Fragment Screening.
Chrysanthopoulos, Panagiotis K; Mujumdar, Prashant; Woods, Lucy A; Dolezal, Olan; Ren, Bin; Peat, Thomas S; Poulsen, Sally-Ann
2017-09-14
The discovery of a new zinc binding chemotype from screening a nonbiased fragment library is reported. Using the orthogonal fragment screening methods of native state mass spectrometry and surface plasmon resonance a 3-unsubstituted 2,4-oxazolidinedione fragment was found to have low micromolar binding affinity to the zinc metalloenzyme carbonic anhydrase II (CA II). This affinity approached that of fragment sized primary benzenesulfonamides, the classical zinc binding group found in most CA II inhibitors. Protein X-ray crystallography established that 3-unsubstituted 2,4-oxazolidinediones bound to CA II via an interaction of the acidic ring nitrogen with the CA II active site zinc, as well as two hydrogen bonds between the oxazolidinedione ring oxygen and the CA II protein backbone. Furthermore, 3-unsubstituted 2,4-oxazolidinediones appear to be a viable starting point for the development of an alternative class of CA inhibitor, wherein the medicinal chemistry pedigree of primary sulfonamides has dominated for several decades.
Ayvaz, Huseyin; Rodriguez-Saona, Luis E
2015-05-01
The most common methods for acrylamide analysis in foods require the use of LC-MS/MS and GC-MS. Although these methods have great analytical performance, they need intensive sample preparation, highly specialised instrumentation, and are time consuming. In this study, portable and handheld infrared spectrometers were evaluated as rapid methods for screening acrylamide in potato chips and their performances were compared to those of benchtop infrared systems. The acrylamide content of 64 commercial potato chips (169-2453 μg/kg) was determined by LC-MS/MS. Spectral data were collected using mid-infrared (MIR) and near-infrared (NIR) spectrometers. Partial least squares regression (PLSR) calibration models were developed to predict acrylamide levels. Overall, good linear correlation was found between the predicted acrylamide levels and actual measured acrylamide concentrations by LC-MS/MS (rPred > 0.90 and SEP < 100 μg/kg). Our results indicate that portable and handheld spectrometers can be used as simple and rapid alternatives for acrylamide analysis in potato chips. Copyright © 2014 Elsevier Ltd. All rights reserved.
García-Serra, J; Ramis, J; Simó, S; Joya, X; Pichini, S; Vall, O; García-Algar, O
2012-11-01
Detection of prenatal drug abuse exposure is essential to ensure an appropriate monitoring of affected children. A maternal questionnaire is not an efficient screening tool. The usefulness of maternal hair and meconium as biological materials to assess this exposure has been described in last few years. The aim of this study was to compare both these alternative biological materials for prenatal drug exposure detection in the third trimester of pregnancy, in order to assess its use as a screening tool. Between January and March 2010, samples of maternal hair and meconium from 107 mother-infant dyads were collected in Can Misses Hospital, Ibiza. The presence of opiates, cocaine, cannabis, and amphetamines, was determined in both materials, using standard chromatographic techniques. Maternal hair analysis showed a 15.9% positivity for drugs of abuse (17 cases): 11 cannabis, 7 cocaine, 1 cannabis and ecstasy, and 1 cannabis and cocaine. Only one mother reported cannabis consumption and another one, cocaine. Of the 7 cocaine positive cases in hair, 6 were confirmed in meconium analysis, while of 11 cannabis positive cases, only 3 were confirmed in meconium. Two different consumer profiles were defined: cocaine consumers and cannabis consumers (with only 2 cases of multiple drug use). The highest level of cocaine ever published was detected (1.582ng/g) in one case. This study reveals a high prevalence of drug abuse in this cohort during pregnancy. Improved screening methods may optimize prevention and monitoring of exposed infants. Maternal hair seems to be more sensitive than meconium to detect prenatal exposure to cannabis during the third trimester, so it might become a good screening tool. Copyright © 2011 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
de Almeida, Sérgio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea E; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K; Ellis, Ronald J
2017-03-01
The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia, but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. A total of 108 participants (including 60 HIV-infected persons) completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible 3-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75%, respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared with the gold standard NP battery, were Trail Making Test A, Wechsler Adult Intelligence Scale III Digit Symbol and Hopkins Verbal Learning Test-Revised Total Recall (sensitivity 91%, specificity 96%), and Digit Symbol, Brief Visuospatial Memory Test-Revised Total Recall and Grooved Pegboard Test-dominant hand (sensitivity 94%, specificity 91%). Both test combinations can be administered in less than 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination.
A prototype software methodology for the rapid evaluation of biomanufacturing process options.
Chhatre, Sunil; Francis, Richard; O'Donovan, Kieran; Titchener-Hooker, Nigel J; Newcombe, Anthony R; Keshavarz-Moore, Eli
2007-10-01
A three-layered simulation methodology is described that rapidly evaluates biomanufacturing process options. In each layer, inferior options are screened out, while more promising candidates are evaluated further in the subsequent, more refined layer, which uses more rigorous models that require more data from time-consuming experimentation. Screening ensures laboratory studies are focused only on options showing the greatest potential. To simplify the screening, outputs of production level, cost and time are combined into a single value using multi-attribute-decision-making techniques. The methodology was illustrated by evaluating alternatives to an FDA (U.S. Food and Drug Administration)-approved process manufacturing rattlesnake antivenom. Currently, antivenom antibodies are recovered from ovine serum by precipitation/centrifugation and proteolyzed before chromatographic purification. Alternatives included increasing the feed volume, replacing centrifugation with microfiltration and replacing precipitation/centrifugation with a Protein G column. The best alternative used a higher feed volume and a Protein G step. By rapidly evaluating the attractiveness of options, the methodology facilitates efficient and cost-effective process development.
Flexible ligand docking using a genetic algorithm
NASA Astrophysics Data System (ADS)
Oshiro, C. M.; Kuntz, I. D.; Dixon, J. Scott
1995-04-01
Two computational techniques have been developed to explore the orientational and conformational space of a flexible ligand within an enzyme. Both methods use the Genetic Algorithm (GA) to generate conformationally flexible ligands in conjunction with algorithms from the DOCK suite of programs to characterize the receptor site. The methods are applied to three enzyme-ligand complexes: dihydrofolate reductase-methotrexate, thymidylate synthase-phenolpthalein and HIV protease-thioketal haloperidol. Conformations and orientations close to the crystallographically determined structures are obtained, as well as alternative structures with low energy. The potential for the GA method to screen a database of compounds is also examined. A collection of ligands is evaluated simultaneously, rather than docking the ligands individually into the enzyme.
Mikkonen, Hannah G; Clarke, Bradley O; Dasika, Raghava; Wallis, Christian J; Reichman, Suzie M
2017-02-15
Understanding ambient background concentrations in soil, at a local scale, is an essential part of environmental risk assessment. Where high resolution geochemical soil surveys have not been undertaken, soil data from alternative sources, such as environmental site assessment reports, can be used to support an understanding of ambient background conditions. Concentrations of metals/metalloids (As, Mn, Ni, Pb and Zn) were extracted from open-source environmental site assessment reports, for soils derived from the Newer Volcanics basalt, of Melbourne, Victoria, Australia. A manual screening method was applied to remove samples that were indicated to be contaminated by point sources and hence not representative of ambient background conditions. The manual screening approach was validated by comparison to data from a targeted background soil survey. Statistical methods for exclusion of contaminated samples from background soil datasets were compared to the manual screening method. The statistical methods tested included the Median plus Two Median Absolute Deviations, the upper whisker of a normal and log transformed Tukey boxplot, the point of inflection on a cumulative frequency plot and the 95th percentile. We have demonstrated that where anomalous sample results cannot be screened using site information, the Median plus Two Median Absolute Deviations is a conservative method for derivation of ambient background upper concentration limits (i.e. expected maximums). The upper whisker of a boxplot and the point of inflection on a cumulative frequency plot, were also considered adequate methods for deriving ambient background upper concentration limits, where the percentage of contaminated samples is <25%. Median ambient background concentrations of metals/metalloids in the Newer Volcanic soils of Melbourne were comparable to ambient background concentrations in Europe and the United States, except for Ni, which was naturally enriched in the basalt-derived soils of Melbourne. Copyright © 2016 Elsevier B.V. All rights reserved.
Lewis, Stephanie N; Brannan, Lera; Guri, Amir J; Lu, Pinyi; Hontecillas, Raquel; Bassaganya-Riera, Josep; Bevan, David R
2011-01-01
Treatments for inflammatory bowel disease (IBD) are modestly effective and associated with side effects from prolonged use. As there is no known cure for IBD, alternative therapeutic options are needed. Peroxisome proliferator-activated receptor-gamma (PPARγ) has been identified as a potential target for novel therapeutics against IBD. For this project, compounds were screened to identify naturally occurring PPARγ agonists as a means to identify novel anti-inflammatory therapeutics for experimental assessment of efficacy. Here we provide complementary computational and experimental methods to efficiently screen for PPARγ agonists and demonstrate amelioration of experimental IBD in mice, respectively. Computational docking as part of virtual screening (VS) was used to test binding between a total of eighty-one compounds and PPARγ. The test compounds included known agonists, known inactive compounds, derivatives and stereoisomers of known agonists with unknown activity, and conjugated trienes. The compound identified through VS as possessing the most favorable docked pose was used as the test compound for experimental work. With our combined methods, we have identified α-eleostearic acid (ESA) as a natural PPARγ agonist. Results of ligand-binding assays complemented the screening prediction. In addition, ESA decreased macrophage infiltration and significantly impeded the progression of IBD-related phenotypes through both PPARγ-dependent and -independent mechanisms in mice with experimental IBD. This study serves as the first significant step toward a large-scale VS protocol for natural PPARγ agonist screening that includes a massively diverse ligand library and structures that represent multiple known target pharmacophores.
Lewis, Stephanie N.; Brannan, Lera; Guri, Amir J.; Lu, Pinyi; Hontecillas, Raquel; Bassaganya-Riera, Josep; Bevan, David R.
2011-01-01
Background Treatments for inflammatory bowel disease (IBD) are modestly effective and associated with side effects from prolonged use. As there is no known cure for IBD, alternative therapeutic options are needed. Peroxisome proliferator-activated receptor-gamma (PPARγ) has been identified as a potential target for novel therapeutics against IBD. For this project, compounds were screened to identify naturally occurring PPARγ agonists as a means to identify novel anti-inflammatory therapeutics for experimental assessment of efficacy. Methodology/Principal Findings Here we provide complementary computational and experimental methods to efficiently screen for PPARγ agonists and demonstrate amelioration of experimental IBD in mice, respectively. Computational docking as part of virtual screening (VS) was used to test binding between a total of eighty-one compounds and PPARγ. The test compounds included known agonists, known inactive compounds, derivatives and stereoisomers of known agonists with unknown activity, and conjugated trienes. The compound identified through VS as possessing the most favorable docked pose was used as the test compound for experimental work. With our combined methods, we have identified α-eleostearic acid (ESA) as a natural PPARγ agonist. Results of ligand-binding assays complemented the screening prediction. In addition, ESA decreased macrophage infiltration and significantly impeded the progression of IBD-related phenotypes through both PPARγ-dependent and –independent mechanisms in mice with experimental IBD. Conclusions/Significance This study serves as the first significant step toward a large-scale VS protocol for natural PPARγ agonist screening that includes a massively diverse ligand library and structures that represent multiple known target pharmacophores. PMID:21904603
Talbot, Thomas R; Schaffner, William; Bloch, Karen C; Daniels, Titus L; Miller, Randolph A
2011-01-01
Objective The authors evaluated algorithms commonly used in syndromic surveillance for use as screening tools to detect potentially clonal outbreaks for review by infection control practitioners. Design Study phase 1 applied four aberrancy detection algorithms (CUSUM, EWMA, space-time scan statistic, and WSARE) to retrospective microbiologic culture data, producing a list of past candidate outbreak clusters. In phase 2, four infectious disease physicians categorized the phase 1 algorithm-identified clusters to ascertain algorithm performance. In phase 3, project members combined the algorithms to create a unified screening system and conducted a retrospective pilot evaluation. Measurements The study calculated recall and precision for each algorithm, and created precision-recall curves for various methods of combining the algorithms into a unified screening tool. Results Individual algorithm recall and precision ranged from 0.21 to 0.31 and from 0.053 to 0.29, respectively. Few candidate outbreak clusters were identified by more than one algorithm. The best method of combining the algorithms yielded an area under the precision-recall curve of 0.553. The phase 3 combined system detected all infection control-confirmed outbreaks during the retrospective evaluation period. Limitations Lack of phase 2 reviewers' agreement indicates that subjective expert review was an imperfect gold standard. Less conservative filtering of culture results and alternate parameter selection for each algorithm might have improved algorithm performance. Conclusion Hospital outbreak detection presents different challenges than traditional syndromic surveillance. Nevertheless, algorithms developed for syndromic surveillance have potential to form the basis of a combined system that might perform clinically useful hospital outbreak screening. PMID:21606134
Avital, Itzhak; Langan, Russell C.; Summers, Thomas A.; Steele, Scott R.; Waldman, Scott A.; Backman, Vadim; Yee, Judy; Nissan, Aviram; Young, Patrick; Womeldorph, Craig; Mancusco, Paul; Mueller, Renee; Noto, Khristian; Grundfest, Warren; Bilchik, Anton J.; Protic, Mladjan; Daumer, Martin; Eberhardt, John; Man, Yan Gao; Brücher, Björn LDM; Stojadinovic, Alexander
2013-01-01
Colorectal cancer (CRC) is the third most common cause of cancer-related death in the United States (U.S.), with estimates of 143,460 new cases and 51,690 deaths for the year 2012. Numerous organizations have published guidelines for CRC screening; however, these numerical estimates of incidence and disease-specific mortality have remained stable from years prior. Technological, genetic profiling, molecular and surgical advances in our modern era should allow us to improve risk stratification of patients with CRC and identify those who may benefit from preventive measures, early aggressive treatment, alternative treatment strategies, and/or frequent surveillance for the early detection of disease recurrence. To better negotiate future economic constraints and enhance patient outcomes, ultimately, we propose to apply the principals of personalized and precise cancer care to risk-stratify patients for CRC screening (Precision Risk Stratification-Based Screening, PRSBS). We believe that genetic, molecular, ethnic and socioeconomic disparities impact oncological outcomes in general, those related to CRC, in particular. This document highlights evidence-based screening recommendations and risk stratification methods in response to our CRC working group private-public consensus meeting held in March 2012. Our aim was to address how we could improve CRC risk stratification-based screening, and to provide a vision for the future to achieving superior survival rates for patients diagnosed with CRC. PMID:23459409
EASI-IMS an expedite and secure technique to screen for 25I-NBOH in blotter papers.
de Morais, Damila Rodrigues; Barbosa, Ingrid Lopes; Cunha, Kelly Francisco; Tripodi, Guilherme Lucas; Angolini, Célio Fernando Figueiredo; Franco, Marcos Fernando; de Aquino, Elvis Medeiros; Eberlin, Marcos Nogueira; Costa, Jose Luiz
2017-10-01
The increasing number of new psychoactive substances (NPS) and their quick worldwide spreading, often only slightly modified in the form of new derivatives and analogues, have brought the need for fast, wide-ranging, and unequivocal identification methods in clinical and forensic investigations. Because it usually provides secure results, gas chromatography coupled to mass spectrometry (GC-MS) has been routinely employed as the standard technique for the detection of NPS in blotter papers. For 25I-NBOH (N-(2-hydroxybenzyl)-2-(4-iodo-2,5-dimethoxyphenyl)ethan-1-aminium), however, GC-MS analysis of an blotter paper extract leads to incorrect results. In this work, we investigated whether easy ambient sonic-spray mass spectrometry imaging (EASI-IMS), and ambient ionization MS method can be applied directly to the surface of the sample requiring therefore no extraction or sample preparations, would serve as an efficient, sensitive, and secure alternative for 25I-NBOH screening. Copyright © 2017 John Wiley & Sons, Ltd.
Gozalbes, Rafael; Carbajo, Rodrigo J; Pineda-Lucena, Antonio
2010-01-01
In the last decade, fragment-based drug discovery (FBDD) has evolved from a novel approach in the search of new hits to a valuable alternative to the high-throughput screening (HTS) campaigns of many pharmaceutical companies. The increasing relevance of FBDD in the drug discovery universe has been concomitant with an implementation of the biophysical techniques used for the detection of weak inhibitors, e.g. NMR, X-ray crystallography or surface plasmon resonance (SPR). At the same time, computational approaches have also been progressively incorporated into the FBDD process and nowadays several computational tools are available. These stretch from the filtering of huge chemical databases in order to build fragment-focused libraries comprising compounds with adequate physicochemical properties, to more evolved models based on different in silico methods such as docking, pharmacophore modelling, QSAR and virtual screening. In this paper we will review the parallel evolution and complementarities of biophysical techniques and computational methods, providing some representative examples of drug discovery success stories by using FBDD.
[Looking for colorectal cancer in the patients iris?].
Herber, S; Rehbein, M; Tepas, T; Pohl, C; Esser, P
2008-06-01
Iridology is a noninvasive method from the field of complementary medicine that is said to detect diseases by looking for abnormalities of pigmentation and structure in the iris. Colorectal cancer is an ideal opportunity for screening programs because of its long period of development. Our study investigated the applicability of iridology as an alternative screening method for colorectal cancer. Digital color slides were obtained from both eyes of 29 patients with histologically diagnosed colorectal cancer and from 29 age- and gender-matched healthy control subjects. The slides were presented in random order to acknowledged iridologists without knowledge of the number of patients in the two categories. The iridologists correctly detected 51.7% and 53.4%, respectively, of the patients' slides; therefore, the likelihood was statistically no better than chance. Sensitivity was, respectively, 58.6% and 55.2%, and specificity was 44.8% and 51.7%. Iridology had no validity as a diagnostic tool for detecting colorectal cancer in this study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W. II; Tsao, C.L.
1996-06-01
This report presents potential screening benchmarks for protection of aquatic life form contaminants in water. Because there is no guidance for screening for benchmarks, a set of alternative benchmarks is presented herein. This report presents the alternative benchmarks for chemicals that have been detected on the Oak Ridge Reservation. It also presents the data used to calculate the benchmarks and the sources of the data. It compares the benchmarks and discusses their relative conservatism and utility. Also included is the updates of benchmark values where appropriate, new benchmark values, secondary sources are replaced by primary sources, and a more completemore » documentation of the sources and derivation of all values are presented.« less
Peng, Lan; Fan, Jialong; Tong, Chunyi; Xie, Zhenhua; Zhao, Chuan; Liu, Xuanming; Zhu, Yonghua; Liu, Bin
2016-09-15
Mung bean nuclease is a single stranded specific DNA and RNA endonuclease purified from mung bean sprouts. It yields 5'-phosphate terminated mono- and oligonucleotides. The activity level of this nuclease can act as a marker to monitor the developmental process of mung bean sprouts. In order to facilitate the activity and physiological analysis of this nuclease, we have developed a biosensing assay system based on the mung bean nuclease-induced single-stranded DNA scission and the affinity difference of graphene oxide for single-stranded DNA containing different numbers of bases. This end-point measurement method can detect mung bean nuclease in a range of 2×10(-4) to 4×10(-2) with a detection limit of 1×10(-4) unit/mL. In addition, we demonstrate the utility of the assay for screening chemical antibiotics and metal ions, resulting in the identification of several inhibitors of this enzyme in vitro. Furthermore, we firstly report that inhibiting mung bean nuclease by gentamycin sulfate and kanamycin in vivo can suppress mung bean sprouts growth. In summary, this method provides an alternative tool for the biochemical analysis for mung bean nuclease and indicates the feasibility of high-throughput screening specific inhibitors of this nuclease in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.
Behavorial assessments of larval zebrafish neurotoxicology
Fishes have long been a popular organism in ecotoxicology research, and are increasingly used in human health research as an alternative animal model for chemical screening. Our laboratory incorporates a zebrafish (Danio rerio) embryo/larval assay to screen chemicals for developm...
Eisenberg, Daniel A; Yu, Mengjing; Lam, Carl W; Ogunseitan, Oladele A; Schoenung, Julie M
2013-09-15
Copper-indium-gallium-selenium-sulfide (CIGS) thin film photovoltaics are increasingly penetrating the market supply for consumer solar panels. Although CIGS is attractive for producing less greenhouse gas emissions than fossil-fuel based energy sources, CIGS manufacturing processes and solar cell devices use hazardous materials that should be carefully considered in evaluating and comparing net environmental benefits of energy products. Through this research, we present a case study on the toxicity hazards associated with alternative materials selection for CIGS manufacturing. We applied two numeric models, The Green Screen for Safer Chemicals and the Toxic Potential Indicator. To improve the sensitivity of the model outputs, we developed a novel, life cycle thinking based hazard assessment method that facilitates the projection of hazards throughout material life cycles. Our results show that the least hazardous CIGS solar cell device and manufacturing protocol consist of a titanium substrate, molybdenum metal back electrode, CuInS₂ p-type absorber deposited by spray pyrolysis, ZnS buffer deposited by spray ion layer gas reduction, ZnO:Ga transparent conducting oxide (TCO) deposited by sputtering, and the encapsulant polydimethylsiloxane. Copyright © 2013 Elsevier B.V. All rights reserved.
Alternative Fuel Research in Fischer-Tropsch Synthesis
NASA Technical Reports Server (NTRS)
Surgenor, Angela D.; Klettlinger, Jennifer L.; Yen, Chia H.; Nakley, Leah M.
2011-01-01
NASA Glenn Research Center has recently constructed an Alternative Fuels Laboratory which is solely being used to perform Fischer-Tropsch (F-T) reactor studies, novel catalyst development and thermal stability experiments. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch synthesis. The purpose of this test facility is to conduct bench scale Fischer-Tropsch (F-T) catalyst screening experiments while focusing on reducing energy inputs, reducing CO2 emissions and increasing product yields within the F-T process. Fischer-Tropsch synthesis is considered a gas to liquid process which reacts syn-gas (a gaseous mixture of hydrogen and carbon monoxide), over the surface of a catalyst material which is then converted into liquids of various hydrocarbon chain length and product distributions1. These hydrocarbons can then be further processed into higher quality liquid fuels such as gasoline and diesel. The experiments performed in this laboratory will enable the investigation of F-T reaction kinetics to focus on newly formulated catalysts, improved process conditions and enhanced catalyst activation methods. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor used solely for cobalt catalyst activation.
2013-01-01
Background Glutaric aciduria type I (GA-I) is a rare metabolic disorder caused by inherited deficiency of glutaryl-CoA dehydrogenase. Despite high prognostic relevance of early diagnosis and start of metabolic treatment as well as an additional cost saving potential later in life, only a limited number of countries recommend newborn screening for GA-I. So far only limited data is available enabling health care decision makers to evaluate whether investing into GA-I screening represents value for money. The aim of our study was therefore to assess the cost-effectiveness of newborn screening for GA-I by tandem mass spectrometry (MS/MS) compared to a scenario where GA-I is not included in the MS/MS screening panel. Methods We assessed the cost-effectiveness of newborn screening for GA-I against the alternative of not including GA-I in MS/MS screening. A Markov model was developed simulating the clinical course of screened and unscreened newborns within different time horizons of 20 and 70 years. Monte Carlo simulation based probabilistic sensitivity analysis was used to determine the probability of GA-I screening representing a cost-effective therapeutic strategy. Results Within a 20 year time horizon, GA-I screening averts approximately 3.7 DALYs (95% CI 2.9 – 4.5) and about one life year is gained (95% CI 0.7 – 1.4) per 100,000 neonates screened initially . Moreover, the screening programme saves a total of around 30,682 Euro (95% CI 14,343 to 49,176 Euro) per 100,000 screened neonates over a 20 year time horizon. Conclusion Within the limitations of the present study, extending pre-existing MS/MS newborn screening programmes by GA-I represents a highly cost-effective diagnostic strategy when assessed under conditions comparable to the German health care system. PMID:24135440
Predicting the effectiveness of the Finnish population-based colorectal cancer screening programme.
Chiu, Sherry Yueh-Hsia; Malila, Nea; Yen, Amy Ming-Fang; Chen, Sam Li-Sheng; Fann, Jean Ching-Yuan; Hakama, Matti
2017-12-01
Objective Because colorectal cancer (CRC) has a long natural history, estimating the effectiveness of CRC screening programmes requires long-term follow-up. As an alternative, we here demonstrate the use of a temporal multi-state natural history model to predict the effectiveness of CRC screening. Methods In the Finnish population-based biennial CRC screening programme using faecal occult blood tests (FOBT), which was conducted in a randomised health services study, we estimated the pre-clinical incidence, the mean sojourn time (MST), and the sensitivity of FOBT using a Markov model to analyse data from 2004 to 2007. These estimates were applied to predict, through simulation, the effects of five rounds of screening on the relative rate of reducing advanced CRC with 6 years of follow-up, and on the reduction in mortality with 10 years of follow-up, in a cohort of 500,000 subjects aged 60 to 69. Results For localised and non-localised CRC, respectively, the MST was 2.06 and 1.36 years and the sensitivity estimates were 65.12% and 73.70%. The predicted relative risk of non-localised CRC and death from CRC in the screened compared with the control population was 0.86 (95% CI: 0.79-0.98) and 0.91 (95% CI: 0.85-1.02), respectively. Conclusion Based on the preliminary results of the Finnish CRC screening programme, our model predicted a 9% reduction in CRC mortality and a 14% reduction in advanced CRC.
Adaptive Gaussian mixture models for pre-screening in GPR data
NASA Astrophysics Data System (ADS)
Torrione, Peter; Morton, Kenneth, Jr.; Besaw, Lance E.
2011-06-01
Due to the large amount of data generated by vehicle-mounted ground penetrating radar (GPR) antennae arrays, advanced feature extraction and classification can only be performed on a small subset of data during real-time operation. As a result, most GPR based landmine detection systems implement "pre-screening" algorithms to processes all of the data generated by the antennae array and identify locations with anomalous signatures for more advanced processing. These pre-screening algorithms must be computationally efficient and obtain high probability of detection, but can permit a false alarm rate which might be higher than the total system requirements. Many approaches to prescreening have previously been proposed, including linear prediction coefficients, the LMS algorithm, and CFAR-based approaches. Similar pre-screening techniques have also been developed in the field of video processing to identify anomalous behavior or anomalous objects. One such algorithm, an online k-means approximation to an adaptive Gaussian mixture model (GMM), is particularly well-suited to application for pre-screening in GPR data due to its computational efficiency, non-linear nature, and relevance of the logic underlying the algorithm to GPR processing. In this work we explore the application of an adaptive GMM-based approach for anomaly detection from the video processing literature to pre-screening in GPR data. Results with the ARA Nemesis landmine detection system demonstrate significant pre-screening performance improvements compared to alternative approaches, and indicate that the proposed algorithm is a complimentary technique to existing methods.
Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.
Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.
2003-12-01
OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.
ERIC Educational Resources Information Center
Mariz, Candice; Carter, Mark; Stephenson, Jennifer
2017-01-01
Visual presentations may assist students with autism spectrum disorder (ASD) to access instruction, and they may be more engaged when interacting with screen media in particular. Interactive whiteboards (IWBs) are large electronic screens that are used for instruction in many classrooms. An alternating treatment design was used to compare the…
Use of an interrupted time-series design to evaluate a cancer screening program.
Michielutte, R; Shelton, B; Paskett, E D; Tatum, C M; Velez, R
2000-10-01
An alternative approach to intervention-control designs to evaluate community health education studies is to use a quasi-experimental design in which the outcomes of interest are examined over time in the intervention unit. The Forsyth County Cancer Screening Project (FoCaS) was a comprehensive clinic- and community-based education program to increase screening for cervical cancer and breast cancer among low-income women. This paper reports the use of piecewise regression accounting for potential effects of auto-correlation in the data to evaluate the effectiveness of the project in increasing mammography screening. Data for the evaluation of trends in screening consisted of all mammograms performed during the period of May 1992 through June 1995 at the Reynolds Health Center in Forsyth County, North Carolina. The results suggested that the FoCaS project was effective in increasing mammography screening among women age 40 or older in the study population. Analysis of the trends by age indicated that the program had differential effects on women age 40-49 and 50 or older. The results demonstrate that analyses of the type presented here can either complement or serve as an alternative to more traditional intervention-control analyses.
Vanstone, Meredith; Kinsella, Elizabeth Anne; Nisker, Jeff
2012-03-01
The 2011 SOGC clinical practice guideline "Prenatal Screening for Fetal Aneuploidy in Singleton Pregnancies" recommends that clinicians offer prenatal screening to all pregnant women and provide counselling in a non-directive manner. Non-directive counselling is intended to facilitate autonomous decision-making and remove the clinician's views regarding a particular course of action. However, recent research in genetic counselling raises concerns that non-directive counselling is neither possible nor desirable, and that it may not be the best way to facilitate informed choice. We propose an alternative model of information-sharing specific to prenatal screening that combines attributes of the models of informative decision-making and shared decision-making. Our proposed model is intended to provide clinicians with a strategy to communicate information about prenatal screening in a way that facilitates a shared deliberative process and autonomous decision-making. Our proposed model may better prepare a pregnant woman to make an informed choice about participating in prenatal screening on the basis of her consideration of the medical information provided by her clinician and her particular circumstances and values.
mRAISE: an alternative algorithmic approach to ligand-based virtual screening
NASA Astrophysics Data System (ADS)
von Behren, Mathias M.; Bietz, Stefan; Nittinger, Eva; Rarey, Matthias
2016-08-01
Ligand-based virtual screening is a well established method to find new lead molecules in todays drug discovery process. In order to be applicable in day to day practice, such methods have to face multiple challenges. The most important part is the reliability of the results, which can be shown and compared in retrospective studies. Furthermore, in the case of 3D methods, they need to provide biologically relevant molecular alignments of the ligands, that can be further investigated by a medicinal chemist. Last but not least, they have to be able to screen large databases in reasonable time. Many algorithms for ligand-based virtual screening have been proposed in the past, most of them based on pairwise comparisons. Here, a new method is introduced called mRAISE. Based on structural alignments, it uses a descriptor-based bitmap search engine (RAISE) to achieve efficiency. Alignments created on the fly by the search engine get evaluated with an independent shape-based scoring function also used for ranking of compounds. The correct ranking as well as the alignment quality of the method are evaluated and compared to other state of the art methods. On the commonly used Directory of Useful Decoys dataset mRAISE achieves an average area under the ROC curve of 0.76, an average enrichment factor at 1 % of 20.2 and an average hit rate at 1 % of 55.5. With these results, mRAISE is always among the top performing methods with available data for comparison. To access the quality of the alignments calculated by ligand-based virtual screening methods, we introduce a new dataset containing 180 prealigned ligands for 11 diverse targets. Within the top ten ranked conformations, the alignment closest to X-ray structure calculated with mRAISE has a root-mean-square deviation of less than 2.0 Å for 80.8 % of alignment pairs and achieves a median of less than 2.0 Å for eight of the 11 cases. The dataset used to rate the quality of the calculated alignments is freely available at http://www.zbh.uni-hamburg.de/mraise-dataset.html. The table of all PDB codes contained in the ensembles can be found in the supplementary material. The software tool mRAISE is freely available for evaluation purposes and academic use (see http://www.zbh.uni-hamburg.de/raise).
Cell-free fetal DNA screening in the USA: a cost analysis of screening strategies.
Evans, M I; Sonek, J D; Hallahan, T W; Krantz, D A
2015-01-01
To determine whether implementation of primary cell-free fetal DNA (cffDNA) screening would be cost-effective in the USA and to evaluate potential lower-cost alternatives. Three strategies to screen for trisomy 21 were evaluated using decision tree analysis: 1) a primary strategy in which cffDNA screening was offered to all patients, 2) a contingent strategy in which cffDNA screening was offered only to patients who were high risk on traditional first-trimester screening and 3) a hybrid strategy in which cffDNA screening was offered to all patients ≥ 35 years of age and only to patients < 35 years who were high risk after first-trimester screening. Four traditional screening protocols were evaluated, each assessing nuchal translucency (NT) and pregnancy-associated plasma protein-A (PAPP-A) along with either free or total beta-human chorionic gonadotropin (β-hCG), with or without nasal bone (NB) assessment. Utilizing a primary cffDNA screening strategy, the cost per patient was 1017 US$. With a traditional screening protocol using free β-hCG, PAPP-A and NT assessment as part of a hybrid screening strategy, a contingent strategy with a 1/300 cut-off and a contingent strategy with a 1/1000 cut-off, the cost per patient was 474, 430 and 409 US$, respectively. Findings were similar using the other traditional screening protocols. Marginal cost per viable case detected for the primary screening strategy as compared to the other strategies was 3-16 times greater than the cost of care for a missed case. Primary cffDNA screening is not currently a cost-effective strategy. The contingent strategy was the lowest-cost alternative, especially with a risk cut-off of 1/1000. The hybrid strategy, although less costly than primary cffDNA screening, was more costly than the contingent strategy. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Alternatives Analysis for the Resumption of Transient Testing Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee Nelson
2013-11-01
An alternatives analysis was performed for resumption of transient testing. The analysis considered eleven alternatives – including both US international facilities. A screening process was used to identify two viable alternatives from the original eleven. In addition, the alternatives analysis includes a no action alternative as required by the National Environmental Policy Act (NEPA). The alternatives considered in this analysis included: 1. Restart the Transient Reactor Test Facility (TREAT) 2. Modify the Annular Core Research Reactor (ACRR) which includes construction of a new hot cell and installation of a new hodoscope. 3. No Action
Punrat, Eakkasit; Chuanuwatanakul, Suchada; Kaneta, Takashi; Motomizu, Shoji; Chailapakul, Orawon
2013-11-15
An automated method has been developed for determining the concentration of inorganic arsenic. The technique uses sequential injection/anodic stripping voltammetry with a long-lasting gold-modified screen-printed carbon electrode. The long-lasting gold electrode was electrochemically deposited onto a screen-printed carbon electrode at a potential of -0.5 V vs. Ag/AgCl in a supporting electrolyte solution of 1M hydrochloric acid. Under optimal conditions and the applied potentials, the electrode demonstrated that it can be used for a long time without a renewal process. The linear range for the determination of arsenic(III) was 1-100 μg L(-1), and the limit of detection (LOD) in standard solutions was as low as 0.03 μg L(-1) for a deposition time of 120 s and sample volume of 1 mL. This method was used to determine the concentration of arsenic(III) in water samples with satisfactory results. The LOD in real samples was found to be 0.5 μg L(-1). In addition, speciation between arsenic(III) and arsenic(V) has been achieved with the proposed method using deposition potentials of -0.5 V and -1.5 V for the determination of the arsenic(III) concentration and the total arsenic concentration, respectively; the results were acceptable. The proposed method is an automated system that offers a less expensive alternative for determining trace amounts of inorganic arsenic. © 2013 Elsevier B.V. All rights reserved.
Jain, Raka; Quraishi, Rizwana; Verma, Arpita
2017-01-01
Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.
A Field Trial of Alternative Targeted Screening Strategies for Chagas Disease in Arequipa, Peru
Hunter, Gabrielle C.; Borrini-Mayorí, Katty; Ancca Juárez, Jenny; Castillo Neyra, Ricardo; Verastegui, Manuela R.; Malaga Chavez, Fernando S.; Cornejo del Carpio, Juan Geny; Córdova Benzaquen, Eleazar; Náquira, César; Gilman, Robert H.; Bern, Caryn; Levy, Michael Z.
2012-01-01
Background Chagas disease is endemic in the rural areas of southern Peru and a growing urban problem in the regional capital of Arequipa, population ∼860,000. It is unclear how to implement cost-effective screening programs across a large urban and periurban environment. Methods We compared four alternative screening strategies in 18 periurban communities, testing individuals in houses with 1) infected vectors; 2) high vector densities; 3) low vector densities; and 4) no vectors. Vector data were obtained from routine Ministry of Health insecticide application campaigns. We performed ring case detection (radius of 15 m) around seropositive individuals, and collected data on costs of implementation for each strategy. Results Infection was detected in 21 of 923 (2.28%) participants. Cases had lived more time on average in rural places than non-cases (7.20 years versus 3.31 years, respectively). Significant risk factors on univariate logistic regression for infection were age (OR 1.02; p = 0.041), time lived in a rural location (OR 1.04; p = 0.022), and time lived in an infested area (OR 1.04; p = 0.008). No multivariate model with these variables fit the data better than a simple model including only the time lived in an area with triatomine bugs. There was no significant difference in prevalence across the screening strategies; however a self-assessment of disease risk may have biased participation, inflating prevalence among residents of houses where no infestation was detected. Testing houses with infected-vectors was least expensive. Ring case detection yielded four secondary cases in only one community, possibly due to vector-borne transmission in this community, apparently absent in the others. Conclusions Targeted screening for urban Chagas disease is promising in areas with ongoing vector-borne transmission; however, these pockets of epidemic transmission remain difficult to detect a priori. The flexibility to adapt to the epidemiology that emerges during screening is key to an efficient case detection intervention. In heterogeneous urban environments, self-assessments of risk and simple residence history questionnaires may be useful to identify those at highest risk for Chagas disease to guide diagnostic efforts. PMID:22253939
Comparison of Alternate and Original Items on the Montreal Cognitive Assessment
Lebedeva, Elena; Huang, Mei; Koski, Lisa
2016-01-01
Background The Montreal Cognitive Assessment (MoCA) is a screening tool for mild cognitive impairment (MCI) in elderly individuals. We hypothesized that measurement error when using the new alternate MoCA versions to monitor change over time could be related to the use of items that are not of comparable difficulty to their corresponding originals of similar content. The objective of this study was to compare the difficulty of the alternate MoCA items to the original ones. Methods Five selected items from alternate versions of the MoCA were included with items from the original MoCA administered adaptively to geriatric outpatients (N = 78). Rasch analysis was used to estimate the difficulty level of the items. Results None of the five items from the alternate versions matched the difficulty level of their corresponding original items. Conclusions This study demonstrates the potential benefits of a Rasch analysis-based approach for selecting items during the process of development of parallel forms. The results suggest that better match of the items from different MoCA forms by their difficulty would result in higher sensitivity to changes in cognitive function over time. PMID:27076861
Rosenwasser, Lara A.; McCall-Hosenfeld, Jennifer S.; Weisman, Carol S.; Hillemeier, Marianne M.; Perry, Amanda N.; Chuang, Cynthia H.
2014-01-01
Introduction Colorectal cancer (CRC) is the third leading cause of death among U.S. women. Rural populations have lower rates of CRC screening than their urban counterparts, and rural women have lower screening rates compared with rural men. The purpose of this qualitative study was to identify (1) primary care physicians’ (PCP) beliefs regarding CRC screening in rural communities, (2) factors that may cause gender disparities in CRC screening in rural areas, and (3) solutions to overcome those barriers. Methods Semi-structured interviews were conducted with 17 PCPs practicing in rural central Pennsylvania. PCPs were asked about their CRC screening practices for women, availability of CRC screening services, reminder systems for CRC screening, and barriers to screening specific to their rural communities and to gender. Thematic analysis was used to identify major themes. Results All 17 PCPs endorsed the importance of CRC screening, but believed that there are barriers to CRC screening specific to women and to rural location. All PCPs identified colonoscopy as their screening method of choice, and generally reported that access to colonoscopy services in their rural areas was not a significant barrier. Barriers to CRC screening for women in rural communities were related to: 1) PCPs’ CRC screening practices (e.g., not using alternative screening modalities when colonoscopy is not possible), 2) gender-specific barriers to CRC screening (e.g., patients’ belief that CRC mostly affects men, embarrassment of knowing people at the endoscopy center, prioritization of family issues over personal health), 3) patient-related barriers (e.g., low educational attainment, low health literacy, poverty, under- or uninsured), 4) community-related barriers (e.g., inadequate public education about CRC, “rural culture” that does not emphasize importance of preventive health services), and 5) physician practice-related barriers (e.g., lack of effective reminder systems, lack of time, busy practices). Physicians overwhelmingly identified patient education as necessary for improving CRC screening in their rural communities, but believed that education would have to come from a source outside the rural primary care office due to lack of resources, personnel, and time. Conclusions Overall, the PCPs in this study were motivated to identify ways to improve their ability to engage more eligible patients in CRC screening. These findings suggest several interventions to potentially improve CRC screening for women in rural areas, including encouraging use of other effective CRC screening modalities (i.e., FOBT) when colonoscopy is not possible; systems-based reminders that leverage electronic resources and are not visit dependent; and public health education campaigns aimed specifically at women in rural communities. PMID:24099635
Detecting Developmental Neurotoxicants Using Zebrafish Embryos
As part of EPA’s program on the screening and prioritization of chemicals for developmental neurotoxicity, a rapid, cost-effective in vivo vertebrate screen is being developed using an alternative species approach. Zebrafish (Danio rerio), a small freshwater fish with external f...
Skally, Mairead; Hanly, Paul; Sharp, Linda
2013-06-01
Fecal DNA (fDNA) testing is a noninvasive potential alternative to current colorectal cancer screening tests. We conducted a systematic review and quality assessment of studies of cost-effectiveness of fDNA as a colorectal cancer screening tool (compared with no screening and other screening modalities), and identified key variables that impinged on cost-effectiveness. We searched MEDLINE, Embase, and the Centre for Reviews and Dissemination for cost-effectiveness studies of fDNA-based screening, published in English by September 2011. Studies that undertook an economic evaluation of fDNA, using either a cost-effectiveness or cost-utility analysis, compared with other relevant screening modalities and/or no screening were included. Additional inclusion criteria related to the presentation of data pertaining to model variables including time horizon, costs, fDNA performance characteristics, screening uptake, and comparators. A total of 369 articles were initially identified for review. After removing duplicates and applying inclusion and exclusion criteria, seven articles were included in the final review. Data was abstracted on key descriptor variables including screening scenarios, time horizon, costs, test performance characteristics, screening uptake, comparators, and incremental cost-effectiveness ratios. Quality assessment was undertaken using a standard checklist for economic evaluations. Studies cited by cost-effectiveness articles as the source of data on fDNA test performance characteristics were also reviewed. Seven cost-effectiveness studies were included, from the USA (4), Canada (1), Israel (1), and Taiwan (1). Markov models (5), a partially observable Markov decision process model (1) and MISCAN and SimCRC (1) microsimulation models were used. All studies took a third-party payer perspective and one included, in addition, a societal perspective. Comparator screening tests, screening intervals, and specific fDNA tests varied between studies. fDNA sensitivity and specificity parameters were derived from 12 research studies and one meta-analysis. Outcomes assessed were life-years gained and quality-adjusted life-years gained. fDNA was cost-effective when compared with no screening in six studies. Compared with other screening modalities, fDNA was not considered cost-effective in any of the base-case analyses: in five studies it was dominated by all alternatives considered. Sensitivity analyses identified cost, compliance, and test parameters as key influential parameters. In general, poor presentation of "study design" and "data collection" details lowered the quality of included articles. Although the literature searches were designed for high sensitivity, the possibility cannot be excluded that some eligible studies may have been missed. Reports (such as Health Technology Assessments produced by government agencies) and other forms of grey literature were excluded because they are difficult to identify systematically and/or may not report methods and results in sufficient detail for assessment. On the basis of the available (albeit limited) evidence, while fDNA is cost-effective when compared with no screening, it is currently dominated by most of the other available screening options. Cost and test performance appear to be the main influences on cost-effectiveness.
An approach to quantitative sustainability assessment in the early stages of process design.
Tugnoli, Alessandro; Santarelli, Francesco; Cozzani, Valerio
2008-06-15
A procedure was developed for the quantitative assessment of key performance indicators suitable for the sustainability analysis of alternative processes, mainly addressing the early stages of process design. The methodology was based on the calculation of a set of normalized impact indices allowing a direct comparison of the additional burden of each process alternative on a selected reference area. Innovative reference criteria were developed to compare and aggregate the impact indicators on the basis of the site-specific impact burden and sustainability policy. An aggregation procedure also allows the calculation of overall sustainability performance indicators and of an "impact fingerprint" of each process alternative. The final aim of the method is to support the decision making process during process development, providing a straightforward assessment of the expected sustainability performances. The application of the methodology to case studies concerning alternative waste disposal processes allowed a preliminary screening of the expected critical sustainability impacts of each process. The methodology was shown to provide useful results to address sustainability issues in the early stages of process design.
Low-cost printing of computerised tomography (CT) images where there is no dedicated CT camera.
Tabari, Abdulkadir M
2007-01-01
Many developing countries still rely on conventional hard copy images to transfer information among physicians. We have developed a low-cost alternative method of printing computerised tomography (CT) scan images where there is no dedicated camera. A digital camera is used to photograph images from the CT scan screen monitor. The images are then transferred to a PC via a USB port, before being printed on glossy paper using an inkjet printer. The method can be applied to other imaging modalities like ultrasound and MRI and appears worthy of emulation elsewhere in the developing world where resources and technical expertise are scarce.
Microfluidic Devices for Drug Delivery Systems and Drug Screening
Kompella, Uday B.; Damiati, Safa A.
2018-01-01
Microfluidic devices present unique advantages for the development of efficient drug carrier particles, cell-free protein synthesis systems, and rapid techniques for direct drug screening. Compared to bulk methods, by efficiently controlling the geometries of the fabricated chip and the flow rates of multiphase fluids, microfluidic technology enables the generation of highly stable, uniform, monodispersed particles with higher encapsulation efficiency. Since the existing preclinical models are inefficient drug screens for predicting clinical outcomes, microfluidic platforms might offer a more rapid and cost-effective alternative. Compared to 2D cell culture systems and in vivo animal models, microfluidic 3D platforms mimic the in vivo cell systems in a simple, inexpensive manner, which allows high throughput and multiplexed drug screening at the cell, organ, and whole-body levels. In this review, the generation of appropriate drug or gene carriers including different particle types using different configurations of microfluidic devices is highlighted. Additionally, this paper discusses the emergence of fabricated microfluidic cell-free protein synthesis systems for potential use at point of care as well as cell-, organ-, and human-on-a-chip models as smart, sensitive, and reproducible platforms, allowing the investigation of the effects of drugs under conditions imitating the biological system. PMID:29462948
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurley, D.F.; Whitehouse, J.M.
A dedicated low-flow groundwater sample collection system was designed for implementation in a post-closure ACL monitoring program at the Yaworski Lagoon NPL site in Canterbury, Connecticut. The system includes dedicated bladder pumps with intake ports located in the screened interval of the monitoring wells. This sampling technique was implemented in the spring of 1993. The system was designed to simultaneously obtain samples directly from the screened interval of nested wells in three distinct water bearing zones. Sample collection is begun upon stabilization of field parameters. Other than line volume, no prior purging of the well is required. It was foundmore » that dedicated low-flow sampling from the screened interval provides a method of representative sample collection without the bias of suspended solids introduced by traditional techniques of pumping and bailing. Analytical data indicate that measured chemical constituents are representative of groundwater migrating through the screened interval. Upon implementation of the low-flow monitoring system, analytical results exhibited a decrease in concentrations of some organic compounds and metals. The system has also proven to be a cost effective alternative to pumping and bailing which generate large volumes of purge water requiring containment and disposal.« less
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2011-01-01
A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.
Liao, Wei-Ching; Chuang, Min-Chieh; Ho, Ja-An Annie
2013-12-15
Genetically modified (GM) technique, one of the modern biomolecular engineering technologies, has been deemed as profitable strategy to fight against global starvation. Yet rapid and reliable analytical method is deficient to evaluate the quality and potential risk of such resulting GM products. We herein present a biomolecular analytical system constructed with distinct biochemical activities to expedite the computational detection of genetically modified organisms (GMOs). The computational mechanism provides an alternative to the complex procedures commonly involved in the screening of GMOs. Given that the bioanalytical system is capable of processing promoter, coding and species genes, affirmative interpretations succeed to identify specified GM event in terms of both electrochemical and optical fashions. The biomolecular computational assay exhibits detection capability of genetically modified DNA below sub-nanomolar level and is found interference-free by abundant coexistence of non-GM DNA. This bioanalytical system, furthermore, sophisticates in array fashion operating multiplex screening against variable GM events. Such a biomolecular computational assay and biosensor holds great promise for rapid, cost-effective, and high-fidelity screening of GMO. Copyright © 2013 Elsevier B.V. All rights reserved.
Bolaños-Díaz, Rafael; Tejada, Romina A; Beltrán, Jessica; Escobedo-Palza, Seimer
2016-01-01
To determine the cost-effectiveness of human papillomavirus (HPV) vaccination and cervical lesion screening versus screening alone for the prevention of uterine cervical cancer (UCC). This cost-effectiveness evaluation from the perspective of the Ministry of Health employed a Markov model with a 70-year time horizon and three alternatives for UCC prevention (screening alone, screening + bivalent vaccine, and screening + quadrivalent vaccine) in a hypothetical cohort of 10-year-old girls. Our model, which was particularly sensitive to variations in coverage and in the prevalence of persistent infection by oncologic genotypes not included in the vaccine, revealed that HPV vaccination and screening is more cost-effective than screening alone, assuming a payment availability from S/ 2 000 (US dollars (USD) 1 290.32) per subject. In the deterministic analysis, the bivalent vaccine was marginally more cost-effective than the quadrivalent vaccine (S/ 48 [USD 30.97] vs. S/ 166 [USD 107.10] per quality-adjusted life-year, respectively). However, in the probabilistic analysis, both interventions generated clouds of overlapping points and were thus cost-effective and interchangeable, although the quadrivalent vaccine tended to be more cost-effective. Assuming a payment availability from S/ 2000 [USD 1,290.32], screening and vaccination were more cost-effective than screening alone. The difference in cost-effectiveness between the two vaccines lacked probabilistic robustness, and therefore the vaccines can be considered interchangeable from a cost-effectiveness perspective.
Green, Eric P; Tuli, Hawa; Kwobah, Edith; Menya, D; Chesire, Irene; Schmidt, Christina
2018-03-01
Routine screening for perinatal depression is not common in most primary health care settings. The U.S. Preventive Services Task Force only recently updated their recommendation on depression screening to specifically recommend screening during the pre- and postpartum periods. While practitioners in high-income countries can respond to this new recommendation by implementing one of several existing depression screening tools developed in Western contexts, such as the Edinburgh Postnatal Depression Scale (EPDS) or the Patient Health Questionnaire-9 (PHQ-9), these tools lack strong evidence of cross-cultural equivalence, validity for case finding, and precision in measuring response to treatment in developing countries. Thus, there is a critical need to develop and validate new screening tools for perinatal depression that can be used by lay health workers, primary health care personnel, and patients. Working in rural Kenya, we used free listing, card sorting, and item analysis methods to develop a locally-relevant screening tool that blended Western psychiatric concepts with local idioms of distress. We conducted a validation study with a random sample of 193 pregnant women and new mothers to test the diagnostic accuracy of this scale along with the EPDS and PHQ-9. The sensitivity/specificity of the EPDS and PHQ-9 was estimated to be 0.70/0.72 and 0.70/0.73, respectively. This compared to sensitivity/specificity of 0.90/0.90 for a new 9-item locally-developed tool called the Perinatal Depression Screening (PDEPS). Across these three tools, internal consistency reliability ranged from 0.77 to 0.81 and test-retest reliability ranged from 0.57 to 0.67. The prevalence of depression ranges from 5.2% to 6.2% depending on the clinical reference standard. The EPDS and PHQ-9 are valid and reliable screening tools for perinatal depression in rural Western Kenya, the PDEPS may be a more useful alternative. At less than 10%, the prevalence of depression in this region appears to be lower than other published estimates for African and other low-income countries. Copyright © 2017 Elsevier B.V. All rights reserved.
Tsagkari, Mirela; Couturier, Jean-Luc; Kokossis, Antonis; Dubois, Jean-Luc
2016-09-08
Biorefineries offer a promising alternative to fossil-based processing industries and have undergone rapid development in recent years. Limited financial resources and stringent company budgets necessitate quick capital estimation of pioneering biorefinery projects at the early stages of their conception to screen process alternatives, decide on project viability, and allocate resources to the most promising cases. Biorefineries are capital-intensive projects that involve state-of-the-art technologies for which there is no prior experience or sufficient historical data. This work reviews existing rapid cost estimation practices, which can be used by researchers with no previous cost estimating experience. It also comprises a comparative study of six cost methods on three well-documented biorefinery processes to evaluate their accuracy and precision. The results illustrate discrepancies among the methods because their extrapolation on biorefinery data often violates inherent assumptions. This study recommends the most appropriate rapid cost methods and urges the development of an improved early-stage capital cost estimation tool suitable for biorefinery processes. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.
Distributional Cost-Effectiveness Analysis
Asaria, Miqdad; Griffin, Susan; Cookson, Richard
2015-01-01
Distributional cost-effectiveness analysis (DCEA) is a framework for incorporating health inequality concerns into the economic evaluation of health sector interventions. In this tutorial, we describe the technical details of how to conduct DCEA, using an illustrative example comparing alternative ways of implementing the National Health Service (NHS) Bowel Cancer Screening Programme (BCSP). The 2 key stages in DCEA are 1) modeling social distributions of health associated with different interventions, and 2) evaluating social distributions of health with respect to the dual objectives of improving total population health and reducing unfair health inequality. As well as describing the technical methods used, we also identify the data requirements and the social value judgments that have to be made. Finally, we demonstrate the use of sensitivity analyses to explore the impacts of alternative modeling assumptions and social value judgments. PMID:25908564
Purohit, Bharathi M; Singh, Abhinav; Dwivedi, Ashish
2017-03-01
The study aims to assess the reliability of video-graphic method as a tool to screen the dental caries among 12-year-old school children in a rural region of India. A total of 139 school children participated in the study. Visual tactile examinations were conducted using the Decayed, Missing, and Filled Teeth (DMFT) index. Simultaneously, standardized video recording of the oral cavity was performed. Sensitivity and specificity values were calculated for video-graphic assessment of dental caries. Bland-Altman plot was used to assess agreement between the two methods of caries assessment. Likelihood ratio (LR) and receiver-operating characteristic (ROC) curve were used to assess the predictive accuracy of the video-graphic method. Mean DMFT for the study population was 2.47 ± 2.01 and 2.46 ± 1.91 by visual tactile and video-graphic assessment (P = 0.76; > 0.05). Sensitivity and specificity values of 0.86 and 0.58 were established for video-graphic assessment. A fair degree of agreement was noted between the two methods with Intraclass correlation coefficient (ICC) value of 0.56. LR for video-graphic assessment was 2.05. Bland-Altman plot confirmed the level of agreement between the two assessment methods. The area under curve was 0.69 (CI 0.57, 0.80, P = 0.001). Teledentistry examination is comparable to clinical examination when screening for dental caries among school children. This study provides evidence that teledentistry may be used as an alternative screening tool for assessment of dental caries and is viable for remote consultation and treatment planning. Teledentistry offers to change the dynamics of dental care delivery and may effectively bridge the rural-urban oral health divide. © 2016 American Association of Public Health Dentistry.
A general strategy for the evolution of bond-forming enzymes using yeast display
Chen, Irwin; Dorr, Brent M.; Liu, David R.
2011-01-01
The ability to routinely generate efficient protein catalysts of bond-forming reactions chosen by researchers, rather than nature, is a long-standing goal of the molecular life sciences. Here, we describe a directed evolution strategy for enzymes that catalyze, in principle, any bond-forming reaction. The system integrates yeast display, enzyme-mediated bioconjugation, and fluorescence-activated cell sorting to isolate cells expressing proteins that catalyze the coupling of two substrates chosen by the researcher. We validated the system using model screens for Staphylococcus aureus sortase A–catalyzed transpeptidation activity, resulting in enrichment factors of 6,000-fold after a single round of screening. We applied the system to evolve sortase A for improved catalytic activity. After eight rounds of screening, we isolated variants of sortase A with up to a 140-fold increase in LPETG-coupling activity compared with the starting wild-type enzyme. An evolved sortase variant enabled much more efficient labeling of LPETG-tagged human CD154 expressed on the surface of HeLa cells compared with wild-type sortase. Because the method developed here does not rely on any particular screenable or selectable property of the substrates or product, it represents a powerful alternative to existing enzyme evolution methods. PMID:21697512
Marquis-Nicholson, Renate; Lai, Daniel; Love, Jennifer M.; Love, Donald R.
2013-01-01
Purpose. The aim of this study was to develop a streamlined mutation screening protocol for the DMD gene in order to confirm a clinical diagnosis of Duchenne or Becker muscular dystrophy in affected males and to clarify the carrier status of female family members. Methods. Sequence analysis and array comparative genomic hybridization (aCGH) were used to identify mutations in the dystrophin DMD gene. We analysed genomic DNA from six individuals with a range of previously characterised mutations and from eight individuals who had not previously undergone any form of molecular analysis. Results. We successfully identified the known mutations in all six patients. A molecular diagnosis was also made in three of the four patients with a clinical diagnosis who had not undergone prior genetic screening, and testing for familial mutations was successfully completed for the remaining four patients. Conclusion. The mutation screening protocol described here meets best practice guidelines for molecular testing of the DMD gene in a diagnostic laboratory. The aCGH method is a superior alternative to more conventional assays such as multiplex ligation-dependent probe amplification (MLPA). The combination of aCGH and sequence analysis will detect mutations in 98% of patients with the Duchenne or Becker muscular dystrophy. PMID:23476807
Wearing surface testing and screening : Yukon River Bridge.
DOT National Transportation Integrated Search
2015-09-01
There is a demand and a need for cheaper and alternative surface coverings in environments with high temperature fluctuations. Our : design for an alternative surface covering involves a basic two-part component epoxy with the addition of a solvent. ...
Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules
2014-04-29
Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre -defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives. Embodiments may also include definition of one or more design apertures, each of which may correspond to boundaries in which solar collector layouts should comply with distinct sets of user-defined design preferences. Distinct apertures may provide heterogeneous regions of collector layout according to the user-defined design preferences.
Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules
2013-01-08
Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre-defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives. Embodiments may also include definition of one or more design apertures, each of which may correspond to boundaries in which solar collector layouts should comply with distinct sets of user-defined design preferences. Distinct apertures may provide heterogeneous regions of collector layout according to the user-defined design preferences.
HRM and SNaPshot as alternative forensic SNP genotyping methods.
Mehta, Bhavik; Daniel, Runa; McNevin, Dennis
2017-09-01
Single nucleotide polymorphisms (SNPs) have been widely used in forensics for prediction of identity, biogeographical ancestry (BGA) and externally visible characteristics (EVCs). Single base extension (SBE) assays, most notably SNaPshot® (Thermo Fisher Scientific), are commonly used for forensic SNP genotyping as they can be employed on standard instrumentation in forensic laboratories (e.g. capillary electrophoresis). High resolution melt (HRM) analysis is an alternative method and is a simple, fast, single tube assay for low throughput SNP typing. This study compares HRM and SNaPshot®. HRM produced reproducible and concordant genotypes at 500 pg, however, difficulties were encountered when genotyping SNPs with high GC content in flanking regions and differentiating variants of symmetrical SNPs. SNaPshot® was reproducible at 100 pg and is less dependent on SNP choice. HRM has a shorter processing time in comparison to SNaPshot®, avoids post PCR contamination risk and has potential as a screening tool for many forensic applications.
Kafwafwa, Savel; Brown, Hilary; Walker, Graeme; Madetsa, Belito; Deeny, Miriam; Kabota, Beatrice; Morton, David; Ter Haar, Reynier; Grant, Liz; Cubie, Heather A.
2016-01-01
The incidence of cervical cancer in Malawi is the highest in the world and projected to increase in the absence of interventions. Although government policy supports screening using visual inspection with acetic acid (VIA), screening provision is limited due to lack of infrastructure, trained personnel, and the cost and availability of gas for cryotherapy. Recently, thermo‐coagulation has been acknowledged as a safe and acceptable procedure suitable for low‐resource settings. We introduced thermo‐coagulation for treatment of VIA‐positive lesions as an alternative to cryotherapy within a cervical screening service based on VIA, coupled with appropriate, sustainable pathways of care for women with high‐grade lesions and cancers. Detailed planning was undertaken for VIA clinics, and approvals were obtained from the Ministry of Health, Regional and Village Chiefs. Educational resources were developed. Thermo‐coagulators were introduced into hospital and health centre settings, with theoretical and practical training in safe use and maintenance of equipment. A total of 7,088 previously unscreened women attended VIA clinics between October 2013 and March 2015. Screening clinics were held daily in the hospital and weekly in the health centres. Overall, VIA positivity was 6.1%. Almost 90% received same day treatment in the hospital setting, and 3‐ to 6‐month cure rates of more than 90% are observed. Thermo‐coagulation proved feasible and acceptable in this setting. Effective implementation requires comprehensive training and provider support, ongoing competency assessment, quality assurance and improvement audit. Thermo‐coagulation offers an effective alternative to cryotherapy and encouraged VIA screening of many more women. PMID:27006131
Jago, R; Zahra, J; Edwards, M J; Kesten, J M; Solomon-Moore, E; Thompson, J L; Sebire, S J
2016-03-01
The present study used qualitative methods to: (1) examine the strategies that were used by parents of children aged 5-6 years to manage screen viewing; (2) identify key factors that affect the implementation of the strategies and (3) develop suggestions for future intervention content. Telephone interviews were conducted with parents of children aged 5-6 years participating in a larger study. Interviews were transcribed verbatim and analysed using an inductive and deductive content analysis. Coding and theme generation was iterative and refined throughout. Parents were recruited through 57 primary schools located in the greater Bristol area (UK). 53 parents of children aged 5-6 years. Parents reported that for many children, screen viewing was a highly desirable behaviour that was difficult to manage, and that parents used the provision of screen viewing as a tool for reward and/or punishment. Parents managed screen viewing by setting limits in relation to daily events such as meals, before and after school, and bedtime. Screen-viewing rules were often altered depending on parental preferences and tasks. Inconsistent messaging within and between parents represented a source of conflict at times. Potential strategies to facilitate reducing screen viewing were identified, including setting screen-viewing limits in relation to specific events, collaborative rule setting, monitoring that involves mothers, fathers and the child, developing a family-specific set of alternative activities to screen viewing and developing a child's ability to self-monitor their own screen viewing. Managing screen viewing is a challenge for many parents and can often cause tension in the home. The data presented in this paper provide key suggestions of new approaches that could be incorporated into behaviour change programmes to reduce child screen viewing. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Jago, R; Zahra, J; Edwards, M J; Kesten, J M; Solomon-Moore, E; Thompson, J L; Sebire, S J
2016-01-01
Objectives The present study used qualitative methods to: (1) examine the strategies that were used by parents of children aged 5–6 years to manage screen viewing; (2) identify key factors that affect the implementation of the strategies and (3) develop suggestions for future intervention content. Design Telephone interviews were conducted with parents of children aged 5–6 years participating in a larger study. Interviews were transcribed verbatim and analysed using an inductive and deductive content analysis. Coding and theme generation was iterative and refined throughout. Setting Parents were recruited through 57 primary schools located in the greater Bristol area (UK). Participants 53 parents of children aged 5–6 years. Results Parents reported that for many children, screen viewing was a highly desirable behaviour that was difficult to manage, and that parents used the provision of screen viewing as a tool for reward and/or punishment. Parents managed screen viewing by setting limits in relation to daily events such as meals, before and after school, and bedtime. Screen-viewing rules were often altered depending on parental preferences and tasks. Inconsistent messaging within and between parents represented a source of conflict at times. Potential strategies to facilitate reducing screen viewing were identified, including setting screen-viewing limits in relation to specific events, collaborative rule setting, monitoring that involves mothers, fathers and the child, developing a family-specific set of alternative activities to screen viewing and developing a child's ability to self-monitor their own screen viewing. Conclusions Managing screen viewing is a challenge for many parents and can often cause tension in the home. The data presented in this paper provide key suggestions of new approaches that could be incorporated into behaviour change programmes to reduce child screen viewing. PMID:26932143
Silver, Michelle I.; Schiffman, Mark; Fetterman, Barbara; Poitras, Nancy; Gage, Julia C.; Wentzensen, Nicolas; Lorey, Thomas; Kinney, Walter; Castle, Philip E.
2016-01-01
Background Cervical screening aims to detect and treat precancer to prevent cervical cancer mortality and morbidity, while minimizing overtreatment of benign human papillomavirus (HPV) infections and related minor abnormalities. HPV/cytology cotesting at extended 5-year intervals is now a recommended screening strategy in the US, but the interval extension is controversial. We studied the impact of a decade of an alternative, 3-year cotesting, on rates of precancer and cancer at Kaiser Permanente Northern California. We also considered the effect on screening efficiency, defined as numbers of cotests/colposcopy visits needed to detect a precancer. Methods Two cohorts were defined. The “open cohort” included all women screened at least once during the study period; >1 million cotests were performed. In a fixed “long-term screening cohort”, we considered the cumulative impact of repeated screening at 3-year intervals by restricting to women first cotested in 2003–4 (i.e., no women entering screening later were added to this group). Results Detection of CIN3/AIS increased in the open cohort (2004–6, 82.0/100,000 women screened; 2007–9, 140.6/100,000; and 2010–12, 126.0/100,000); cancer diagnoses were unchanged. In the long-term screening cohort, detection of CIN3/AIS increased then decreased to the original level (2004–6, 80.5/100,000; 2007–9, 118.6/100,000; and 2010–2, 84.9/100,000). Cancer diagnoses decreased. Seen in terms of screening efficiency, the number of colposcopies performed todetect a single CIN3/AIS increased in the cohort with repeat screening. Conclusion Repeated cotesting at a 3-year interval eventually lowers population rates of precancer and cancer; however, a greater number of colposcopies is required to detect a single precancer. PMID:27657992
Kengne, Andre Pascal; Erasmus, Rajiv T; Levitt, Naomi S; Matsha, Tandi E
2017-04-01
Accurate diabetes diagnosis is important in Africa, where rates are increasing, and the disease largely undiagnosed. The cumbersome oral glucose tolerance test (OGTT) remains the reference standard, while alternative diagnostic methods are not yet established in Africans. We assessed the ability of fasting plasma glucose (FPG), HbA1c and fructosamine, to diagnose OGTT-based abnormal glucose tolerance in mixed-ancestry South Africans. Mixed-ancestry adults, residing in Cape Town were examined between February and November 2015. OGTT values were used to classify glucose tolerance status as: screen-detected diabetes, prediabetes, dysglycaemia (combination of diabetes and prediabetes) and normal glucose tolerance. Of the 793 participants included, 65 (8.2%) had screen-detected diabetes, 157 (19.8%) prediabetes and 571 (72.0%) normal glucose tolerance. Correlations of FPG and 2-h glucose with HbA1c (r=0.51 and 0.52) were higher than those with fructosamine (0.34 and 0.30), both p<0.0001. The highest c-statistic for the prediction of abnormal glucose tolerance was recorded with 2-h glucose [c-statistic=0.997 (screen-detected diabetes), 0.979 (prediabetes) and 0.984 (dysglycaemia)] and the lowest with fructosamine (0.865, 0.596 and 0.677). At recommended or data-specific optimal cut-offs, no combination of FPG, HbA1c and fructosamine did better than 2-h glucose, while FPG was better than HbA1c and fructosamine on a range of performance measures. Abnormal glucose tolerance in this population is overwhelmingly expressed through 2-h glucose's abnormalities; and no combination of FPG, HbA1c and fructosamine was effective at accurately discriminating OGTT-defined abnormal glucose tolerance. Tested non-glucose based strategies are unreliable alternatives to OGTT for dysglycaemia diagnosis in this population. Copyright © 2017 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.
Alonso, Pau; Osca, Joaquín; Cano, Oscar; Pimenta, Pedro; Andrés, Ana; Yagüe, Jaime; Millet, José; Rueda, Joaquín; Sancho-Tello, María José
2017-02-01
Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P < 0.0001) and a trend to higher number of appropriate leads in right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P < 0.001). Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population. © 2017 Wiley Periodicals, Inc.
Johnson, Susan L; Tabaei, Bahman P; Herman, William H
2005-02-01
To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.
Haug, Ulrike; Knudsen, Amy B; Lansdorp-Vogelaar, Iris; Kuntz, Karen M
2015-06-15
Researchers are actively pursuing the development of a new non-invasive test (NIT) for colorectal cancer (CRC) screening as an alternative to fecal occult blood tests (FOBTs). The majority of pilot studies focus on the detection of invasive CRC rather than precursor lesions (i.e., adenomas). We aimed to explore the relevance of adenoma detection for the viability of an NIT for CRC screening by considering a hypothetical test that does not detect adenomas beyond chance. We used the Simulation Model of Colorectal Cancer (SimCRC) to estimate the effectiveness of CRC screening and the lifetime costs (payers' perspective) for a cohort of US 50-years-old persons to whom CRC screening is offered from age 50-75. We compared annual screening with guaiac and immunochemical FOBTs (with sensitivities up to 70 and 24% for CRC and adenomas, respectively) to annual screening with a hypothetical NIT (sensitivity of 90% for CRC, no detection of adenomas beyond chance, specificity and cost similar to FOBTs). Screening with the NIT was not more effective, but was 29-44% more costly than screening with FOBTs. The findings were robust to varying the screening interval, the NIT's sensitivity for CRC, adherence rates favoring the NIT, and the NIT's unit cost. A comparative modelling approach using a model that assumes a shorter adenoma dwell time (MISCAN-COLON) confirmed the superiority of the immunochemical FOBT over an NIT with no ability to detect adenomas. Information on adenoma detection is crucial to determine whether a new NIT is a viable alternative to FOBTs for CRC screening. Current evidence thus lacks an important piece of information to identify marker candidates that hold real promise and deserve further (large-scale) evaluation. © 2014 UICC.
Validation of an ELISA Synthetic Cannabinoids Urine Assay.
Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A
2015-10-01
Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, coadministered drugs, over-the-counter medications, or structurally similar compounds, and 19 of 73 individual synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.
Addressing safety aspects of drugs and environmental chemicals has historically been undertaken through animal testing. However, the quantity of chemicals needing assessment and the challenge of species extrapolation require development of alternative approaches. Assessing phenot...
DEMONSTRATION OF WATERBASED PLATEN ADHESIVES FOR GARMENT SCREEN PRINTERS
The paper discusses a demonstration of waterbased platen adhesives as a viable alternative to the organic-based aerosol adhesives that are predominantly used by garment screen printers to affix garments or fabric pieces to print platens. o demonstrate this, the effectiveness of s...
Identifying Structural Alerts Based on Zebrafish Developmental Morphological Toxicity (TDS)
Zebrafish constitute a powerful alternative animal model for chemical hazard evaluation. To provide an in vivo complement to high-throughput screening data from the ToxCast program, zebrafish developmental toxicity screens were conducted on the ToxCast Phase I (Padilla et al., 20...
Sparse information exists on many chemicals to guide developmental neurotoxicity (DNT) risk assessments. As DNT testing using rodents is laborious and expensive, alternative species such as zebrafish are being adapted for toxicity screening. Assessing the DNT potential of chem...
Phase I and II feasibility study report for the 300-FF-5 operable unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1993-12-31
The purpose of this Phase I/II feasibility study is to assemble and screen a list of alternatives for remediation of the 300-FF-5 operable site on the Hanford Reservation. This screening is based on information gathered in the Phase I Remedial Investigation (RI) and on currently available information on remediation technologies. The alternatives remaining after screening provide a range of response actions for remediation. In addition, key data needs are identified for collection during a Phase II RI (if necessary). This Phase I/II FS represents a primary document as defined by the Tri-Party Agreement, but will be followed by a Phasemore » III FS that will further develop the alternatives and provide a detailed evaluation of them. The following remedial action objectives were identified for the 300-FF-5 operable unit: Limit current human exposure to contaminated groundwater in the unit; Limit discharge of contaminated groundwater to the Columbia River; Reduce contaminant concentrations in groundwater below acceptable levels by the year 2018.« less
Gopal, Hemavathi; Hassan, Hassan K.; Rodríguez-Pérez, Mario A.; Toé, Laurent D.; Lustigman, Sara; Unnasch, Thomas R.
2012-01-01
Background Entomological surveys of Simulium vectors are an important component in the criteria used to determine if Onchocerca volvulus transmission has been interrupted and if focal elimination of the parasite has been achieved. However, because infection in the vector population is quite rare in areas where control has succeeded, large numbers of flies need to be examined to certify transmission interruption. Currently, this is accomplished through PCR pool screening of large numbers of flies. The efficiency of this process is limited by the size of the pools that may be screened, which is in turn determined by the constraints imposed by the biochemistry of the assay. The current method of DNA purification from pools of vector black flies relies upon silica adsorption. This method can be applied to screen pools containing a maximum of 50 individuals (from the Latin American vectors) or 100 individuals (from the African vectors). Methodology/Principal Findings We have evaluated an alternative method of DNA purification for pool screening of black flies which relies upon oligonucleotide capture of Onchocerca volvulus genomic DNA from homogenates prepared from pools of Latin American and African vectors. The oligonucleotide capture assay was shown to reliably detect one O. volvulus infective larva in pools containing 200 African or Latin American flies, representing a two-four fold improvement over the conventional assay. The capture assay requires an equivalent amount of technical time to conduct as the conventional assay, resulting in a two-four fold reduction in labor costs per insect assayed and reduces reagent costs to $3.81 per pool of 200 flies, or less than $0.02 per insect assayed. Conclusions/Significance The oligonucleotide capture assay represents a substantial improvement in the procedure used to detect parasite prevalence in the vector population, a major metric employed in the process of certifying the elimination of onchocerciasis. PMID:22724041
Robotham, Julie V; Deeny, Sarah R; Fuller, Chris; Hopkins, Susan; Cookson, Barry; Stone, Sheldon
2016-03-01
In December, 2010, National Health Service (NHS) England introduced national mandatory screening of all admissions for meticillin-resistant Staphylococcus aureus (MRSA). We aimed to assess the effectiveness and cost-effectiveness of this policy, from a regional or national health-care decision makers' perspective, compared with alternative screening strategies. We used an individual-based dynamic transmission model parameterised with national MRSA audit data to assess the effectiveness and cost-effectiveness of admission screening of patients in English NHS hospitals compared with five alternative strategies (including no screening, checklist-activated screening, and high-risk specialty-based screening), accompanied by patient isolation and decolonisation, over a 5 year time horizon. We evaluated strategies for different NHS hospital types (acute, teaching, and specialist), MRSA prevalence, and transmission potentials using probabilistic sensitivity analyses. Compared with no screening, mean cost per quality-adjusted life-year (QALY) of screening all admissions was £89,000-148,000 (range £68,000-222,000), and this strategy was consistently more costly and less effective than alternatives for all hospital types. At a £30,000/QALY willingness-to-pay threshold and current prevalence, only the no-screening strategy was cost effective. The next best strategies were, in acute and teaching hospitals, targeting of high-risk specialty admissions (30-40% chance of cost-effectiveness; mean incremental cost-effectiveness ratios [ICERs] £45,200 [range £35,300-61,400] and £48,000/QALY [£34,600-74,800], respectively) and, in specialist hospitals, screening these patients plus risk-factor-based screening of low-risk specialties (a roughly 20% chance of cost-effectiveness; mean ICER £62,600/QALY [£48,000-89,400]). As prevalence and transmission increased, targeting of high-risk specialties became the optimum strategy at the NHS willingness-to-pay threshold (£30,000/QALY). Switching from screening all admissions to only high-risk specialty admissions resulted in a mean reduction in total costs per year (not considering uncertainty) of £2·7 million per acute hospital, £2·9 million per teaching, and £474,000 per specialist hospital for a minimum rise in infections (about one infection per year per hospital). Our results show that screening all admissions for MRSA is unlikely to be cost effective in England at the current NHS willingness-to-pay threshold, and our findings informed modified guidance to NHS England in 2014. Screening admissions to high-risk specialties is likely to represent better resource use in terms of cost per QALY gained. UK Department of Health. Copyright © 2016 Elsevier Ltd. All rights reserved.
Postal urine specimens: are they a feasible method for genital chlamydial infection screening?
Macleod, J; Rowsell, R; Horner, P; Crowley, T; Caul, E O; Low, N; Smith, G D
1999-01-01
BACKGROUND: A United Kingdom (UK) screening programme for Chlamydia trachomatis has recently been announced. Pilot projects involving the opportunistic testing of women attending health facilities are due to commence in several sites. There is a danger that this approach will fail to obtain adequate population coverage. The alternative--true systematic population screening--is generally assumed to be unfeasible. Studies in Denmark using postal urine specimens have challenged this assumption. No such studies have been reported from the UK. AIM: To assess the potential of urine specimens sent by post as the basis for a UK population screening strategy for genital chlamydial infection. METHOD: Two hundred patients (100 men, 100 women) aged 18 to 45 years were randomly sampled from the list of one urban group practice. Subjects were mailed an explanatory letter, a urine sample container, a sexual lifestyle questionnaire, and a prepaid return envelope. Non-responders were contacted by telephone; persistent non-responders were visited at home. Samples were tested for Chlamydia by DNA amplification and enzyme immunoassay. RESULTS: Sixty-four (32%) subjects were no longer living at their GP registered address. Of the remaining 136, 126 (93%) responded to the survey and 113 (83%) accepted the request for a urine sample and completed a questionnaire. Acceptance rates were similar for men and women and across age groups. Four samples (3%) were Chlamydia positive. CONCLUSION: Home mailed urine specimen collection in conjunction with a self-completed postal questionnaire is feasible. This could provide a viable basis both for determining population Chlamydia prevalence and for a UK Chlamydia population screening strategy. Overall cost effectiveness of such a strategy will depend on the cost of the test used. Comparative performance characteristics of the different currently available tests in this setting have yet to be fully determined. PMID:10562745
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W., II
1993-01-01
One of the initial stages in ecological risk assessment of hazardous waste sites is the screening of contaminants to determine which, if any, of them are worthy of further consideration; this process is termed contaminant screening. Screening is performed by comparing concentrations in ambient media to benchmark concentrations that are either indicative of a high likelihood of significant effects (upper screening benchmarks) or of a very low likelihood of significant effects (lower screening benchmarks). Exceedance of an upper screening benchmark indicates that the chemical in question is clearly of concern and remedial actions are likely to be needed. Exceedance ofmore » a lower screening benchmark indicates that a contaminant is of concern unless other information indicates that the data are unreliable or the comparison is inappropriate. Chemicals with concentrations below the lower benchmark are not of concern if the ambient data are judged to be adequate. This report presents potential screening benchmarks for protection of aquatic life from contaminants in water. Because there is no guidance for screening benchmarks, a set of alternative benchmarks is presented herein. The alternative benchmarks are based on different conceptual approaches to estimating concentrations causing significant effects. For the upper screening benchmark, there are the acute National Ambient Water Quality Criteria (NAWQC) and the Secondary Acute Values (SAV). The SAV concentrations are values estimated with 80% confidence not to exceed the unknown acute NAWQC for those chemicals with no NAWQC. The alternative chronic benchmarks are the chronic NAWQC, the Secondary Chronic Value (SCV), the lowest chronic values for fish and daphnids, the lowest EC20 for fish and daphnids from chronic toxicity tests, the estimated EC20 for a sensitive species, and the concentration estimated to cause a 20% reduction in the recruit abundance of largemouth bass. It is recommended that ambient chemical concentrations be compared to all of these benchmarks. If NAWQC are exceeded, the chemicals must be contaminants of concern because the NAWQC are applicable or relevant and appropriate requirements (ARARs). If NAWQC are not exceeded, but other benchmarks are, contaminants should be selected on the basis of the number of benchmarks exceeded and the conservatism of the particular benchmark values, as discussed in the text. To the extent that toxicity data are available, this report presents the alternative benchmarks for chemicals that have been detected on the Oak Ridge Reservation. It also presents the data used to calculate the benchmarks and the sources of the data. It compares the benchmarks and discusses their relative conservatism and utility. This report supersedes a prior aquatic benchmarks report (Suter and Mabrey 1994). It adds two new types of benchmarks. It also updates the benchmark values where appropriate, adds some new benchmark values, replaces secondary sources with primary sources, and provides more complete documentation of the sources and derivation of all values.« less
Bisht, Naveen C; Jagannath, Arun; Burma, Pradeep K; Pradhan, Akshay K; Pental, Deepak
2007-06-01
We report in this study, an improved method for identifying male sterile-restorer combinations using the barnase-barstar system of pollination control for heterosis breeding in crop plants, as an alternative to the conventional line x tester cross method. In this strategy, a transgenic male sterile barnase line was retransformed with appropriate barstar constructs. Double transformants carrying both the barnase and barstar genes were identified and screened for their male fertility status. Using this strategy, 66-90% of fertile retransformants (restored events) were obtained in Brassica juncea using two different barstar constructs. Restored events were analysed for their pollen viability and copy number of the barstar gene. Around 90% of the restored events showed high pollen viability and approximately 30% contained single copy integrations of the barstar gene. These observations were significantly different from those made in our earlier studies using line (barnase) x tester (barstar) crosses, wherein only two viable male sterile-restorer combinations were identified by screening 88 different cross-combinations. The retransformation strategy not only generated several independent restorers for a given male sterile line from a single transformation experiment but also identified potential restorers in the T(0) generation itself leading to significant savings in time, cost and labour. Single copy restored plants with high pollen viability were selfed to segregate male sterile (barnase) and restorer (barstar) lines in the T(1) progeny which could subsequently be diversified into appropriate combiners for heterosis breeding. This strategy will be particularly useful for crop plants where poor transformation frequencies and/or lengthy transformation protocols are a major limitation.
Guo, Baoshan; Lei, Cheng; Ito, Takuro; Jiang, Yiyue; Ozeki, Yasuyuki; Goda, Keisuke
2016-01-01
The development of reliable, sustainable, and economical sources of alternative fuels is an important, but challenging goal for the world. As an alternative to liquid fossil fuels, algal biofuel is expected to play a key role in alleviating global warming since algae absorb atmospheric CO2 via photosynthesis. Among various algae for fuel production, Euglena gracilis is an attractive microalgal species as it is known to produce wax ester (good for biodiesel and aviation fuel) within lipid droplets. To date, while there exist many techniques for inducing microalgal cells to produce and accumulate lipid with high efficiency, few analytical methods are available for characterizing a population of such lipid-accumulated microalgae including E. gracilis with high throughout, high accuracy, and single-cell resolution simultaneously. Here we demonstrate high-throughput, high-accuracy, single-cell screening of E. gracilis with fluorescence-assisted optofluidic time-stretch microscopy-a method that combines the strengths of microfluidic cell focusing, optical time-stretch microscopy, and fluorescence detection used in conventional flow cytometry. Specifically, our fluorescence-assisted optofluidic time-stretch microscope consists of an optical time-stretch microscope and a fluorescence analyzer on top of a hydrodynamically focusing microfluidic device and can detect fluorescence from every E. gracilis cell in a population and simultaneously obtain its image with a high throughput of 10,000 cells/s. With the multi-dimensional information acquired by the system, we classify nitrogen-sufficient (ordinary) and nitrogen-deficient (lipid-accumulated) E. gracilis cells with a low false positive rate of 1.0%. This method holds promise for evaluating cultivation techniques and selective breeding for microalgae-based biofuel production.
Kim, James A; Ptolemy, Adam S; Melanson, Stacy E F; Janfaza, David R; Ross, Edgar L
2015-06-01
The urine of a patient admitted for chest and epigastric pain tested positive for cocaine using an immunoassay-based drug screening method (positive/negative cutoff concentration 150 ng/mL). Despite the patient's denial of recent cocaine use, this positive cocaine screening result in conjunction with a remote history of drug misuse impacted the patient's recommended pain therapy. Specifically, these factors prompted the clinical team to question the appropriateness of opioids and other potentially addictive therapeutics during the treatment of cancer pain from previously undetected advanced pancreatic carcinoma. After pain management and clinical pathology consultation, it was decided that the positive cocaine screening result should be confirmed by gas chromatography-mass spectrometry (GC-MS) testing. This more sensitive and specific analytical technique revealed that both cocaine and its primary metabolite benzoylecgonine were undetectable (i.e., less than the assay detection limit of 50 ng/mL), thus indicating that the positive urine screening result was falsely positive. With this confirmation, the pain management service team was reassured in offering intrathecal pump (ITP) therapy for pain control. ITP implantation was well tolerated, and the patient eventually achieved excellent pain relief. However, ITP therapy most likely would not have been utilized without the GC-MS confirmation testing unless alternative options failed and extensive vigilant monitoring was initiated. As exemplified in this case, confirmatory drug testing should be performed on specimens with unexpected immunoassay-based drug screening results. To our knowledge, this is the first report of a false-positive urine cocaine screening result and its impact on patient management. Wiley Periodicals, Inc.
Cervical Cancer Screening Among Homeless Women of New York City Shelters.
Asgary, Ramin; Alcabes, Analena; Feldman, Rebecca; Garland, Victoria; Naderi, Ramesh; Ogedegbe, Gbenga; Sckell, Blanca
2016-06-01
Introduction Homeless persons have minimal opportunities to complete recommended cancer screening. The rates and predictors of cervical cancer screening are understudied among homeless women in the US. Methods We enrolled 297 homeless women 21-65 years old residing in 6 major New York City shelters from 2012 to 2014. We used a validated national survey to determine the proportion and predictors of cervical cancer screening using cytology (Pap test). Results Mean age was 44.72 (±11.96) years. Majority was Black, heterosexual, single, with high school or lower education; 50.9 % were smokers and 41.7 % were homeless more than a year. Despite a 76.5 % proportion of self-reported Pap test within the past 3 years, 65 % of women assumed their Pap test results were normal or did not get proper follow up after abnormal results. Forty-five-point-nine percent of women did not know about frequency of Pap test or causes of cervical cancer. Lower proportion of up-to-date Pap test was associated with lack of knowledge of recommended Pap test frequency (p < 0.01) and relationship between HPV and an abnormal Pap test (p < 0.01). Conclusions Self-reported Pap testing in homeless women was similar to a national sample. However, the majority of women surveyed were not aware of their results, received limited if any follow up and had significant education gaps about cervical cancer screening. We recommend improved counseling and patient education, patient navigators to close screening loops, and consideration of alternative test-and-treat modalities to improve effective screening.
Nshimyumukiza, Léon; Durand, Audrey; Gagnon, Mathieu; Douville, Xavier; Morin, Suzanne; Lindsay, Carmen; Duplantie, Julie; Gagné, Christian; Jean, Sonia; Giguère, Yves; Dodin, Sylvie; Rousseau, François; Reinharz, Daniel
2013-01-01
A patient-level Markov decision model was used to simulate a virtual cohort of 500,000 women 40 years old and over, in relation to osteoporosis-related hip, clinical vertebral, and wrist bone fractures events. Sixteen different screening options of three main scenario groups were compared: (1) the status quo (no specific national prevention program); (2) a universal primary prevention program; and (3) a universal screening and treatment program based on the 10-year absolute risk of fracture. The outcomes measured were total directs costs from the perspective of the public health care system, number of fractures, and quality-adjusted life-years (QALYs). Results show that an option consisting of a program promoting physical activity and treatment if a fracture occurs is the most cost-effective (CE) (cost/fracture averted) alternative and also the only cost saving one, especially for women 40 to 64 years old. In women who are 65 years and over, bone mineral density (BMD)-based screening and treatment based on the 10-year absolute fracture risk calculated using a Canadian Association of Radiologists and Osteoporosis Canada (CAROC) tool is the best next alternative. In terms of cost-utility (CU), results were similar. For women less than 65 years old, a program promoting physical activity emerged as cost-saving but BMD-based screening with pharmacological treatment also emerged as an interesting alternative. In conclusion, a program promoting physical activity is the most CE and CU option for women 40 to 64 years old. BMD screening and pharmacological treatment might be considered a reasonable alternative for women 65 years old and over because at a healthcare capacity of $50,000 Canadian dollars ($CAD) for each additional fracture averted or for one QALY gained its probabilities of cost-effectiveness compared to the program promoting physical activity are 63% and 75%, respectively, which could be considered socially acceptable. Consideration of the indirect costs could change these findings. PMID:22991210
Sahin, Deniz; Taflan, Sevket Onur; Yartas, Gizem; Ashktorab, Hassan; Smoot, Duane T
2018-04-25
Background: Gastric cancer is the second most common cancer among the malign cancer types. Inefficiency of traditional techniques both in diagnosis and therapy of the disease makes the development of alternative and novel techniques indispensable. As an alternative to traditional methods, tumor specific targeting small peptides can be used to increase the efficiency of the treatment and reduce the side effects related to traditional techniques. The aim of this study is screening and identification of individual peptides specifically targeted to human gastric cancer cells using a phage-displayed peptide library and designing specific peptide sequences by using experimentally-eluted peptide sequences. Methods: Here, MKN-45 human gastric cancer cells and HFE-145 human normal gastric epithelial cells were used as the target and control cells, respectively. 5 rounds of biopannning with a phage display 12-peptide library were applied following subtraction biopanning with HFE-145 control cells. The selected phage clones were established by enzyme-linked immunosorbent assay and immunofluorescence detection. We first obtain random phage clones after five biopanning rounds, determine the binding levels of each individual clone. Then, we analyze the frequencies of each amino acid in best binding clones to determine positively overexpressed amino acids for designing novel peptide sequences. Results: DE532 (VETSQYFRGTLS) phage clone was screened positive, showing specific binding on MKN-45 gastric cancer cells. DE-Obs (HNDLFPSWYHNY) peptide, which was designed by using amino acid frequencies of experimentally selected peptides in the 5th round of biopanning, showed specific binding in MKN-45 cells. Conclusion: Selection and characterization of individual clones may give us specifically binding peptides, but more importantly, data extracted from eluted phage clones may be used to design theoretical peptides with better binding properties than even experimentally selected ones. Both peptides, experimental and designed, may be potential candidates to be developed as useful diagnostic or therapeutic ligand molecules in gastric cancer research. Creative Commons Attribution License
Chary, Anita Nandkumar; Rohloff, Peter J
2014-01-01
ABSTRACT Background: Like many other low- and middle-income countries, Guatemala has adopted visual inspection with acetic acid (VIA) as a low-resource alternative to the Pap smear for cervical cancer screening. Nongovernmental organizations (NGOs) introduced VIA to Guatemala in 2004, and a growing number of NGOs, working both independently and in collaboration with the Guatemalan Ministry of Health, employ VIA in cervical cancer prevention programs today. While much research describes VIA efficacy and feasibility in Latin America, little is known about NGO involvement with VIA programming or experiences with VIA outside the context of clinical trials and pilot projects in the region. Methods: To explore challenges faced by NGOs implementing VIA programs in Guatemala, we conducted semi-structured interviews with 36 NGO staff members involved with 20 VIA programs as direct service providers, program administrators, and training course instructors. Additionally, we collected data through observation at 30 NGO-sponsored cervical cancer screening campaigns, 8 cervical cancer prevention conferences, and 1 week-long NGO-sponsored VIA training course. Results: Frequently highlighted challenges included staff turnover, concerns over training quality, a need for opportunities for continued supervision, and problems with cryotherapy referrals when immediate treatment for VIA-positive women was unavailable. Conclusions: Reducing staff turnover, budgeting to train replacement providers, standardizing training curricula, and offering continued supervision are key strategies to improve VIA service quality and program sustainability. Alternative training methods, such as on-the-job mentoring and course prerequisites of online learning, could help increase training time available for clinical supervision. Efforts should be made to ensure that VIA testing is coupled with immediate cryotherapy, that providers trained in VIA are also trained in cryotherapy, and that cryotherapy supplies and equipment are maintained. Where this is not possible and only VIA screening is available, referral systems must be strengthened. PMID:25276590
DOE Office of Scientific and Technical Information (OSTI.GOV)
DOE /NV
This Corrective Action Decision Document has been prepared for Corrective Action Unit 340, the NTS Pesticide Release Sites, in accordance with the Federal Facility Agreement and Consent Order of 1996 (FFACO, 1996). Corrective Action Unit 340 is located at the Nevada Test Site, Nevada, and is comprised of the following Corrective Action Sites: 23-21-01, Area 23 Quonset Hut 800 Pesticide Release Ditch; 23-18-03, Area 23 Skid Huts Pesticide Storage; and 15-18-02, Area 15 Quonset Hut 15-11 Pesticide Storage. The purpose of this Corrective Action Decision Document is to identify and provide a rationale for the selection of a recommended correctivemore » action alternative for each Corrective Action Site. The scope of this Corrective Action Decision Document consists of the following tasks: Develop corrective action objectives; Identify corrective action alternative screening criteria; Develop corrective action alternatives; Perform detailed and comparative evaluations of the corrective action alternatives in relation to the corrective action objectives and screening criteria; and Recommend and justify a preferred corrective action alternative for each Corrective Action Site.« less
A review of designer anabolic steroids in equine sports.
Waller, Christopher C; McLeod, Malcolm D
2017-09-01
In recent years, the potential for anabolic steroid abuse in equine sports has increased due to the growing availability of designer steroids. These compounds are readily accessible online in 'dietary' or 'nutritional' supplements and contain steroidal compounds which have never been tested or approved as veterinary agents. They typically have unusual structures or substitution and as a result may pass undetected through current anti-doping screening protocols, making them a significant concern for the integrity of the industry. Despite considerable focus in human sports, until recently there has been limited investigation into these compounds in equine systems. To effectively respond to the threat of designer steroids, a detailed understanding of their metabolism is needed to identify markers and metabolites arising from their misuse. A summary of the literature detailing the metabolism of these compounds in equine systems is presented with an aim to identify metabolites suitable for incorporation into screening protocols by anti-doping laboratories. The future of equine anti-doping research is likely to be guided by the incorporation of alternate testing matrices into routine screening, the improvement of in vitro technologies that can mimic in vivo equine metabolism, and the improvement of instrumentation or analytical methods that allow for the development of untargeted screening, and metabolomics approaches for use in anti-doping screening protocols. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Volk, Robert J.; Jibaja-Weiss, Maria L.; Hawley, Sarah T.; Kneuper, Suzanne; Spann, Stephen J.; Miles, Brian J.; Hyman, David J.
2008-01-01
Objective To evaluate an entertainment-based patient decision aid for prostate cancer screening among patients with low or high health literacy. Methods Male primary care patients from two clinical sites, one characterized as serving patients with low health literacy (n=149) and the second as serving patients with high health literacy (n=301), were randomized to receive an entertainment-based decision aid for prostate cancer screening or an audiobooklet-control aid with the same learner content but without the entertainment features. Postintervention and 2-week follow-up assessments were conducted. Results Patients at the low-literacy site were more engaged with the entertainment-based aid than patients at the high-literacy site. Overall, knowledge improved for all patients. Among patients at the low-literacy site, the entertainment-based aid was associated with lower decisional conflict and greater self-advocacy (i.e., mastering and obtaining information about screening) when compared to patients given the audiobooklet. No differences between the aids were observed for patients at the high-literacy site. Conclusions Entertainment education may be an effective strategy for promoting informed decision making about prostate cancer screening among patients with lower health literacy. Practice Implications As barriers to implementing computer-based patient decision support programs decrease, alternative models for delivering these programs should be explored. PMID:18760888
Accuracy of visual inspection performed by community health workers in cervical cancer screening.
Driscoll, Susan D; Tappen, Ruth M; Newman, David; Voege-Harvey, Kathi
2018-05-22
Cervical cancer remains the leading cause of cancer and mortality in low-resource areas with healthcare personnel shortages. Visual inspection is a low-resource alternative method of cervical cancer screening in areas with limited access to healthcare. To assess accuracy of visual inspection performed by community health workers (CHWs) and licensed providers, and the effect of provider training on visual inspection accuracy. Five databases and four websites were queried for studies published in English up to December 31, 2015. Derivations of "cervical cancer screening" and "visual inspection" were search terms. Visual inspection screening studies with provider definitions, colposcopy reference standards, and accuracy data were included. A priori variables were extracted by two independent reviewers. Bivariate linear mixed-effects models were used to compare visual inspection accuracy. Provider type was a significant predictor of visual inspection sensitivity (P=0.048); sensitivity was 15 percentage points higher among CHWs than physicians (P=0.014). Components of provider training were significant predictors of sensitivity and specificity. Community-based visual inspection programs using adequately trained CHWs could reduce barriers and expand access to screening, thereby decreasing cervical cancer incidence and mortality for women at highest risk and those living in remote areas with limited access to healthcare personnel. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Schwimmer, J B; Newton, K P; Awai, H I; Choi, L J; Garcia, M A; Ellis, L L; Vanderwall, K; Fontanesi, J
2013-01-01
Background Screening overweight and obese children for non-alcoholic fatty liver disease (NAFLD) is recommended by paediatric and endocrinology societies. However, gastroenterology societies have called for more data before making a formal recommendation. Aim To determine whether the detection of suspected NAFLD in overweight and obese children through screening in primary care and referral to paediatric gastroenterology resulted in a correct diagnosis of NAFLD. Methods Information generated in the clinical evaluation of 347 children identified with suspected NAFLD through screening in primary care and referral to paediatric gastroenterology was captured prospectively. Diagnostic outcomes were reported. The diagnostic performance of two times the upper limit of normal (ULN) for alanine aminotransferase (ALT) was assessed. Results Non-alcoholic fatty liver disease was diagnosed in 55% of children identified by screening and referral. Liver disease other than NAFLD was present in 18% of those referred. Autoimmune hepatitis was the most common alternative diagnosis. Children with NAFLD had significantly (P < 0.05) higher screening ALT (98 ± 95) than children with liver disease other than NAFLD (86 ± 74). Advanced fibrosis was present in 11% of children. For the diagnosis of NAFLD, screening ALT two times the clinical ULN had a sensitivity of 57% and a specificity of 71%. Conclusions Screening of overweight and obese children in primary care for NAFLD with referral to paediatric gastroenterology has the potential to identify clinically relevant liver pathology. Consensus is needed on how to value the risk and rewards of screening and referral, to identify children with liver disease in the most appropriate manner. PMID:24117728
Putting engineering back into protein engineering: bioinformatic approaches to catalyst design.
Gustafsson, Claes; Govindarajan, Sridhar; Minshull, Jeremy
2003-08-01
Complex multivariate engineering problems are commonplace and not unique to protein engineering. Mathematical and data-mining tools developed in other fields of engineering have now been applied to analyze sequence-activity relationships of peptides and proteins and to assist in the design of proteins and peptides with specified properties. Decreasing costs of DNA sequencing in conjunction with methods to quickly synthesize statistically representative sets of proteins allow modern heuristic statistics to be applied to protein engineering. This provides an alternative approach to expensive assays or unreliable high-throughput surrogate screens.
Simple TLC-screening of acylglycerol levels in biodiesel as an alternative to GC determination.
Fontana, J D; Zagonel, G; Vechiatto, W W; Costa, B J; Laurindo, J C; Fontana, R; Pelisson, L; Jorge, B H; Lanças, F M
2009-10-01
Thin layer chromatography (TLC) stained with hot acidic p-anisaldehyde, is an interesting, fast, and low-cost technique to monitor main lipid contaminants such as triacylglycerols, diacylglycerols, and monoacylglycerols in biodiesel. These acylglycerols are detectable by the proposed planar chromatographic method, provided the content of the contaminants exceeds the limits recommended by the international norms applicable to biodiesel quality/specification, namely 0.25% in mass for total combined glycerin. The TLC data are confirmed by gas chromatography of the methyl esters of soy oil.
Chaikuad, Apirat; Knapp, Stefan; von Delft, Frank
2015-01-01
The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant. PMID:26249344
Chaikuad, Apirat; Knapp, Stefan; von Delft, Frank
2015-08-01
The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.
Vogt, Martin; Bajorath, Jürgen
2008-01-01
Bayesian classifiers are increasingly being used to distinguish active from inactive compounds and search large databases for novel active molecules. We introduce an approach to directly combine the contributions of property descriptors and molecular fingerprints in the search for active compounds that is based on a Bayesian framework. Conventionally, property descriptors and fingerprints are used as alternative features for virtual screening methods. Following the approach introduced here, probability distributions of descriptor values and fingerprint bit settings are calculated for active and database molecules and the divergence between the resulting combined distributions is determined as a measure of biological activity. In test calculations on a large number of compound activity classes, this methodology was found to consistently perform better than similarity searching using fingerprints and multiple reference compounds or Bayesian screening calculations using probability distributions calculated only from property descriptors. These findings demonstrate that there is considerable synergy between different types of property descriptors and fingerprints in recognizing diverse structure-activity relationships, at least in the context of Bayesian modeling.
Sutton, Andrew J; Edmunds, W John; Gill, O Noel
2006-01-01
Background In England and Wales where less than 1% of the population are Injecting drug users (IDUs), 97% of HCV reports are attributed to injecting drug use. As over 60% of the IDU population will have been imprisoned by the age of 30 years, prison may provide a good location in which to offer HCV screening and treatment. The aim of this work is to examine the cost effectiveness of a number of alternative HCV case-finding strategies on prison reception Methods A decision analysis model embedded in a model of the flow of IDUs through prison was used to estimate the cost effectiveness of a number of alternative case-finding strategies. The model estimates the average cost of identifying a new case of HCV from the perspective of the health care provider and how these estimates may evolve over time. Results The results suggest that administering verbal screening for a past positive HCV test and for ever having engaged in illicit drug use prior to the administering of ELISA and PCR tests can have a significant impact on the cost effectiveness of HCV case-finding strategies on prison reception; the discounted cost in 2017 being £2,102 per new HCV case detected compared to £3,107 when no verbal screening is employed. Conclusion The work here demonstrates the importance of targeting those individuals that have ever engaged in illicit drug use for HCV testing in prisons, these individuals can then be targeted for future intervention measures such as treatment or monitored to prevent future transmission. PMID:16803622
Clinical Validity of hearScreen™ Smartphone Hearing Screening for School Children.
Mahomed-Asmail, Faheema; Swanepoel, De Wet; Eikelboom, Robert H; Myburgh, Hermanus C; Hall, James
2016-01-01
The study aimed to determine the validity of a smartphone hearing screening technology (hearScreen™) compared with conventional screening audiometry in terms of (1) sensitivity and specificity, (2) referral rate, and (3) test time. One thousand and seventy school-age children in grades 1 to 3 (8 ± 1.1 average years) were recruited from five public schools. Children were screened twice, once using conventional audiometry and once with the smartphone hearing screening. Screening was conducted in a counterbalanced sequence, alternating initial screen between conventional or smartphone hearing screening. No statistically significant difference in performance between techniques was noted, with smartphone screening demonstrating equivalent sensitivity (75.0%) and specificity (98.5%) to conventional screening audiometry. While referral rates were lower with the smartphone screening (3.2 vs. 4.6%), it was not significantly different (p > 0.05). Smartphone screening (hearScreen™) was 12.3% faster than conventional screening. Smartphone hearing screening using the hearScreen™ application is accurate and time efficient.
A Cost-Utility Analysis of Prostate Cancer Screening in Australia.
Keller, Andrew; Gericke, Christian; Whitty, Jennifer A; Yaxley, John; Kua, Boon; Coughlin, Geoff; Gianduzzo, Troy
2017-02-01
The Göteborg randomised population-based prostate cancer screening trial demonstrated that prostate-specific antigen (PSA)-based screening reduces prostate cancer deaths compared with an age-matched control group. Utilising the prostate cancer detection rates from this study, we investigated the clinical and cost effectiveness of a similar PSA-based screening strategy for an Australian population of men aged 50-69 years. A decision model that incorporated Markov processes was developed from a health system perspective. The base-case scenario compared a population-based screening programme with current opportunistic screening practices. Costs, utility values, treatment patterns and background mortality rates were derived from Australian data. All costs were adjusted to reflect July 2015 Australian dollars (A$). An alternative scenario compared systematic with opportunistic screening but with optimisation of active surveillance (AS) uptake in both groups. A discount rate of 5 % for costs and benefits was utilised. Univariate and probabilistic sensitivity analyses were performed to assess the effect of variable uncertainty on model outcomes. Our model very closely replicated the number of deaths from both prostate cancer and background mortality in the Göteborg study. The incremental cost per quality-adjusted life-year (QALY) for PSA screening was A$147,528. However, for years of life gained (LYGs), PSA-based screening (A$45,890/LYG) appeared more favourable. Our alternative scenario with optimised AS improved cost utility to A$45,881/QALY, with screening becoming cost effective at a 92 % AS uptake rate. Both modelled scenarios were most sensitive to the utility of patients before and after intervention, and the discount rate used. PSA-based screening is not cost effective compared with Australia's assumed willingness-to-pay threshold of A$50,000/QALY. It appears more cost effective if LYGs are used as the relevant outcome, and is more cost effective than the established Australian breast cancer screening programme on this basis. Optimised utilisation of AS increases the cost effectiveness of prostate cancer screening dramatically.
Popova, Daria; Stonier, Adam; Pain, David; Titchener‐Hooker, Nigel J.
2016-01-01
Abstract Increases in mammalian cell culture titres and densities have placed significant demands on primary recovery operation performance. This article presents a methodology which aims to screen rapidly and evaluate primary recovery technologies for their scope for technically feasible and cost‐effective operation in the context of high cell density mammalian cell cultures. It was applied to assess the performance of current (centrifugation and depth filtration options) and alternative (tangential flow filtration (TFF)) primary recovery strategies. Cell culture test materials (CCTM) were generated to simulate the most demanding cell culture conditions selected as a screening challenge for the technologies. The performance of these technology options was assessed using lab scale and ultra scale‐down (USD) mimics requiring 25–110mL volumes for centrifugation and depth filtration and TFF screening experiments respectively. A centrifugation and depth filtration combination as well as both of the alternative technologies met the performance selection criteria. A detailed process economics evaluation was carried out at three scales of manufacturing (2,000L, 10,000L, 20,000L), where alternative primary recovery options were shown to potentially provide a more cost‐effective primary recovery process in the future. This assessment process and the study results can aid technology selection to identify the most effective option for a specific scenario. PMID:27067803
Worrall, T A; Schmeckpeper, B J; Corvera, J S; Cotter, R J
2000-11-01
The primer oligomer base extension (PROBE) reaction, combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, is used to characterize HLA-DR2 polymorphism. Alleles are distinguished rapidly and accurately by measuring the mass of primer extension products at every known variable region of HLA-DR2 alleles. Since differentiation of alleles by PROBE relies on measuring differences in extension product mass rather than differences in hybridization properties, mistyped alleles resulting from nonspecific hybridization are absent. The method shows considerable potential for high-throughput screening of HLA-DR polymorphism in a chip-based format, including rapid tissue typing of unrelated volunteer donors.
Web accessibility support for visually impaired users using link content analysis.
Iwata, Hajime; Kobayashi, Naofumi; Tachibana, Kenji; Shirogane, Junko; Fukazawa, Yoshiaki
2013-12-01
Web pages are used for a variety of purposes. End users must understand dynamically changing content and sequentially follow page links to find desired material, requiring significant time and effort. However, for visually impaired users using screen readers, it can be difficult to find links to web pages when link text and alternative text descriptions are inappropriate. Our method supports the discovery of content by analyzing 8 categories of link types, and allows visually impaired users to be aware of the content represented by links in advance. This facilitates end users access to necessary information on web pages. Our method of classifying web page links is therefore effective as a means of evaluating accessibility.
Classification of Coffee Beans by GC-C-IRMS, GC-MS, and (1)H-NMR.
Arana, Victoria Andrea; Medina, Jessica; Esseiva, Pierre; Pazos, Diego; Wist, Julien
2016-01-01
In a previous work using (1)H-NMR we reported encouraging steps towards the construction of a robust expert system for the discrimination of coffees from Colombia versus nearby countries (Brazil and Peru), to assist the recent protected geographical indication granted to Colombian coffee in 2007. This system relies on fingerprints acquired on a 400 MHz magnet and is thus well suited for small scale random screening of samples obtained at resellers or coffee shops. However, this approach cannot easily be implemented at harbour's installations, due to the elevated operational costs of cryogenic magnets. This limitation implies shipping the samples to the NMR laboratory, making the overall approach slower and thereby more expensive and less attractive for large scale screening at harbours. In this work, we report on our attempt to obtain comparable classification results using alternative techniques that have been reported promising as an alternative to NMR: GC-MS and GC-C-IRMS. Although statistically significant information could be obtained by all three methods, the results show that the quality of the classifiers depends mainly on the number of variables included in the analysis; hence NMR provides an advantage since more molecules are detected to obtain a model with better predictions.
Using Skype as an Alternative for Residency Selection Interviews
Edje, Louito; Miller, Christine; Kiefer, Jacklyn; Oram, David
2013-01-01
Background Residency interviews can place significant time and financial burdens on applicants. Objective To determine whether the use of Skype as a screening tool during interview season in a family medicine residency is cost-effective and time-efficient for the applicant and the residency program. Methods We surveyed 2 groups of medical students during interviews for our family medicine program. Thirty-two students were interviewed via our face-to-face, traditional interview (TI) process, and 10 students, the second group, who did not meet the program's standard interview selection criteria for TI, underwent our Skype interview (SI) process. Results Using an unpaired t test, we found that the applicants' costs of an SI were significantly less than a TI, $566 (95% confidence interval [CI] $784–$349, P < .001). Direct cash savings plus indirect salary savings to the program were $5,864, with a time savings of 7 interview days. Three of the applicants who were participants in the SI limb of the study were in our final rank order list. Conclusions For interviewing in family medicine residencies, use of Skype may be a cost-effective and time-efficient screening tool for both the applicant and the program. Alternate uses of SI may include the time-sensitive, postmatch Supplemental Offer and Acceptance Program. PMID:24404318
Classification of Coffee Beans by GC-C-IRMS, GC-MS, and 1H-NMR
Arana, Victoria Andrea; Esseiva, Pierre; Pazos, Diego
2016-01-01
In a previous work using 1H-NMR we reported encouraging steps towards the construction of a robust expert system for the discrimination of coffees from Colombia versus nearby countries (Brazil and Peru), to assist the recent protected geographical indication granted to Colombian coffee in 2007. This system relies on fingerprints acquired on a 400 MHz magnet and is thus well suited for small scale random screening of samples obtained at resellers or coffee shops. However, this approach cannot easily be implemented at harbour's installations, due to the elevated operational costs of cryogenic magnets. This limitation implies shipping the samples to the NMR laboratory, making the overall approach slower and thereby more expensive and less attractive for large scale screening at harbours. In this work, we report on our attempt to obtain comparable classification results using alternative techniques that have been reported promising as an alternative to NMR: GC-MS and GC-C-IRMS. Although statistically significant information could be obtained by all three methods, the results show that the quality of the classifiers depends mainly on the number of variables included in the analysis; hence NMR provides an advantage since more molecules are detected to obtain a model with better predictions. PMID:27516919
Arnold, Suzanne V; Lipska, Kasia J; Inzucchi, Silvio E; Li, Yan; Jones, Philip G; McGuire, Darren K; Goyal, Abhinav; Stolker, Joshua M; Lind, Marcus; Spertus, John A; Kosiborod, Mikhail
2014-01-01
Objective Incident diabetes mellitus (DM) is important to recognize in patients with acute myocardial infarction (AMI). To develop an efficient screening strategy, we explored the use of random plasma glucose (RPG) at admission and fasting plasma glucose (FPG) to select patients with AMI for glycosylated hemoglobin (HbA1c) testing. Design, setting, andparticipants Prospective registry of 1574 patients with AMI not taking glucose-lowering medication from 24 US hospitals. All patients had HbA1c measured at a core laboratory and admission RPG and ≥2 FPGs recorded during hospitalization. We examined potential combinations of RPG and FPG and compared these with HbA1c≥6.5%—considered the gold standard for DM diagnosis in these analyses. Results An RPG>140 mg/dL or FPG≥126 mg/dL had high sensitivity for DM diagnosis. Combining these into a screening protocol (if admission RPG>140, check HbA1c; or if FPG≥126 on a subsequent day, check HbA1c) led to HbA1c testing in 50% of patients and identified 86% with incident DM (number needed to screen (NNS)=3.3 to identify 1 case of DM; vs NNS=5.6 with universal HbA1c screening). Alternatively, using an RPG>180 led to HbA1c testing in 40% of patients with AMI and identified 82% of DM (NNS=2.7). Conclusions We have established two potential selective screening methods for DM in the setting of AMI that could identify the vast majority of incident DM by targeted screening of 40–50% of patients with AMI with HbA1c testing. Using these methods may efficiently identify patients with AMI with DM so that appropriate education and treatment can be promptly initiated. PMID:25452878
McLachlan, E.; Anderson, S.; Hawkes, D.; Saville, M.; Arabena, K.
2018-01-01
Objectives To examine factors that enhance under-screened and never-screened women’s completion of the self-collection alternative pathway of the Renewed National Cervical Screening Program (ncsp) in Victoria, Australia. Background With the Australian ncsp changing, starting on 1 December 2017, the Medical Services Advisory Committee (msac) recommended implementing human papillomavirus (hpv) testing using a self-collected sample for under-screened and never-screened populations. In response, a multi-agency group implemented an hpv self-collection pilot project to trial self-collection screening pathways for eligible women. Methods Quantitative data were collected on participation rates and compliance rates with follow-up procedures across three primary health care settings. Forty women who self-collected were interviewed in a semi-structured format, and seven agency staff completed in-depth interviews. Qualitative data were used to identify and understand clinical and personal enablers that assisted women to complete self-collection cervical screening pathways successfully. Results Eighty-five per cent (10 women) of participants who tested positive for hpv successfully received their results and completed follow-up procedures as required. Two remaining participants also received hpv-positive results. However, agencies were unable to engage them in follow-up services and procedures. The overall participation rate in screening (self-collection or Pap test) was 85.7% (84 women), with 79 women self-collecting. Qualitative data indicated that clear explanations on self-collection, development of trusting, empathetic relationships with health professionals, and recognition of participants’ past experiences were critical to the successful completion of the self-collection pathway. When asked about possible inhibitors to screening and to following up on results and appointments, women cited poor physical and mental health, as well as financial and other structural barriers. Conclusion A well-implemented process, led by trusted, knowledgeable, and engaged health care professionals who can provide appropriate support and information, can assist under-screened and never-screened women to complete the hpv self-collection pathway successfully. PMID:29507491
Hunter, Sara A; Morris, Colleen; Nelson, Karl; Snyder, Brandon J; Poulton, Thomas B
2017-05-01
The purpose of this study was to determine whether digital breast tomosynthesis (DBT) is a cost-effective alternative to full-field digital mammography (FFDM) for both Medicare and privately insured patients undergoing screening mammography. A retrospective data analysis was performed between July 15, 2013, and July 14, 2014, with data on women presenting for screening mammography that included any additional radiologic workup (n = 6319). Patients chose to undergo DBT or FFDM on the basis of personal preference, physician suggestion, and cost difference. The summation of findings over the 1-year period were used to calculate recall rates, cancer detection rates, and billing costs for a regional private insurer and Medicare. Data from the 6319 patients who participated were divided: 3655 patients underwent DBT, and 2664 underwent FFDM during the year of screening. Private insurance billing cost $2.9 million, and Medicare cost $1.2 million for screening, follow-up imaging, and radiologic procedures. Per-person costs were approximately $40 higher for the DBT group using both forms of insurance. However, cost per cancer detected was lower in the DBT group for both private and governmental insurance, leading to potentially $3.7 million and $899,000 saved per 100 cancers found. After standardization of the difference in cancer detection rates between the two groups, DBT was a cost-equivalent alternative to FFDM for private insurance billing but was a cost-inefficient alternative with respect to Medicare costs. In a community-based setting, DBT is a cost-equivalent or potentially cost-effective alternative to FFDM and has the capacity for improving cancer detection and recall rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W. II; Mabrey, J.B.
1994-07-01
This report presents potential screening benchmarks for protection of aquatic life from contaminants in water. Because there is no guidance for screening benchmarks, a set of alternative benchmarks is presented herein. The alternative benchmarks are based on different conceptual approaches to estimating concentrations causing significant effects. For the upper screening benchmark, there are the acute National Ambient Water Quality Criteria (NAWQC) and the Secondary Acute Values (SAV). The SAV concentrations are values estimated with 80% confidence not to exceed the unknown acute NAWQC for those chemicals with no NAWQC. The alternative chronic benchmarks are the chronic NAWQC, the Secondary Chronicmore » Value (SCV), the lowest chronic values for fish and daphnids from chronic toxicity tests, the estimated EC20 for a sensitive species, and the concentration estimated to cause a 20% reduction in the recruit abundance of largemouth bass. It is recommended that ambient chemical concentrations be compared to all of these benchmarks. If NAWQC are exceeded, the chemicals must be contaminants of concern because the NAWQC are applicable or relevant and appropriate requirements (ARARs). If NAWQC are not exceeded, but other benchmarks are, contaminants should be selected on the basis of the number of benchmarks exceeded and the conservatism of the particular benchmark values, as discussed in the text. To the extent that toxicity data are available, this report presents the alternative benchmarks for chemicals that have been detected on the Oak Ridge Reservation. It also presents the data used to calculate benchmarks and the sources of the data. It compares the benchmarks and discusses their relative conservatism and utility.« less
Correlation functional in screened-exchange density functional theory procedures.
Chan, Bun; Kawashima, Yukio; Hirao, Kimihiko
2017-10-15
In the present study, we have explored several prospects for the further development of screened-exchange density functional theory (SX-DFT) procedures. Using the performance of HSE06 as our measure, we find that the use of alternative correlation functionals (as oppose to PBEc in HSE06) also yields adequate results for a diverse set of thermochemical properties. We have further examined the performance of new SX-DFT procedures (termed HSEB-type methods) that comprise the HSEx exchange and a (near-optimal) reparametrized B97c (c OS,0 = c SS,0 = 1, c OS,1 = -1.5, c OS,2 = -0.644, c SS,1 = -0.5, and c SS,2 = 1.10) correlation functionals. The different variants of HSEB all perform comparably to or slightly better than the original HSE-type procedures. These results, together with our fundamental analysis of correlation functionals, point toward various directions for advancing SX-DFT methods. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
The applicability of chemical alternatives assessment for engineered nanomaterials.
Hjorth, Rune; Hansen, Steffen Foss; Jacobs, Molly; Tickner, Joel; Ellenbecker, Michael; Baun, Anders
2017-01-01
The use of alternatives assessment to substitute hazardous chemicals with inherently safer options is gaining momentum worldwide as a legislative and corporate strategy to minimize consumer, occupational, and environmental risks. Engineered nanomaterials represent an interesting case for alternatives assessment approaches, because they can be considered both emerging "chemicals" of concern, as well as potentially safer alternatives to hazardous chemicals. However, comparing the hazards of nanomaterials to traditional chemicals or to other nanomaterials is challenging, and critical elements in chemical hazard and exposure assessment may have to be fundamentally altered to sufficiently address nanomaterials. The aim of this paper is to assess the overall applicability of alternatives assessment methods for nanomaterials and to outline recommendations to enhance their use in this context. The present paper focuses on the adaptability of existing hazard and exposure assessment approaches to engineered nanomaterials as well as strategies to design inherently safer nanomaterials. We argue that alternatives assessment for nanomaterials is complicated by the sheer number of nanomaterials possible. As a result, the inclusion of new data tools that can efficiently and effectively evaluate nanomaterials as substitutes is needed to strengthen the alternatives assessment process. However, we conclude that with additional tools to enhance traditional hazard and exposure assessment modules of alternatives assessment, such as the use of mechanistic toxicity screens and control banding tools, alternatives assessment can be adapted to evaluate engineered nanomaterials as potential substitutes for chemicals of concern and to ensure safer nanomaterials are incorporated in the design of new products. Integr Environ Assess Manag 2017;13:177-187. © 2016 SETAC. © 2016 SETAC.
Evaluation of Intraosseous Fluid as an Alternative Biological Specimen in Postmortem Toxicology.
Rodda, Luke N; Volk, Justin A; Moffat, Ellen; Williams, Chinyere M; Lynch, Kara L; Wu, Alan H B
2018-04-01
The postmortem redistribution phenomenon is an important factor in the interpretation of blood drug concentrations as a cause or factor in death. Intraosseous fluid (IOF) may serve as an alternative matrix for drug testing. Intraosseous fluid was collected from the left and right tibias and humerus of 29 decedents using the Arrow EZ-IO Intraosseous Vascular Access System. Standard autopsy specimens including blood were also collected at the same time during autopsy. Blood and IOF specimens were screened by immunoassay for opioids, fentanyl analogs, oxycodone, methadone, cocaine, methamphetamine, amphetamines, phencyclidine, tricyclic antidepressants, benzodiazepines and cannabinoids, using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Correlation between cardiac/central blood ELISA and IOF ELISA results was mostly 100% for drug targets. Further blood confirmation analysis was performed by gas chromatography mass spectrometry also showed comparable correlation to IOF screen results. There was no significant difference between the IOF sites or sides of the body. This novel study supports the use of IOF as an alternative postmortem specimen for toxicological investigations as a potentially less-compromised tissue in decomposed or traumatized bodies. Preliminary data is provided for the screening of common drugs of abuse in IOF that may show to be subject to alternative rates of postmortem redistribution than to that of other biological specimens in future studies that quantitate IOF drug concentrations.
Joint breast and colorectal cancer screenings in medically underserved women
Davis, Terry C; Arnold, Connie L; Wolf, Michael S; Bennett, Charles L; Liu, Dachao; Rademaker, Alfred
2016-01-01
Background Breast and colon cancer screening in rural community clinics is underused. Objective To evaluate the effectiveness and cost-effectiveness of alternative interventions designed to promote simultaneous screening for breast and colon cancer in community clinics. Methods A 3-arm, quasi-experimental evaluation was conducted during May 2008-August 2011 in 8 federally qualifed health clinics in predominately rural Louisiana. Baseline screening rates reported by the clinics was <10% for breast cancer (using mammography) and 1%-2% for colon cancer (using the fecal occult blood test [FOBT]). 744 women aged 50 years or older who were eligible for routine mammography and an FOBT were recruited. The combined screening efforts included: enhanced care; health literacy-informed education (education alone), or health literacy-informed education with nurse support (nurse support). Results Postintervention screening rates for completing both tests were 28.1% with enhanced care, 23.7% with education alone, and 38.7% with nurse support. After adjusting for age, race, and literacy, patients who received nurse support were 2.21 times more likely to complete both screenings than were those who received the education alone (95% confidence interval [CI], 1.12-4.38; P = .023). The incremental cost per additional woman completing both screenings was $3,987 for education with nurse support over education alone, and $5,987 over enhanced care. Limitations There were differences between the 3 arms in sociodemographic characteristics, literacy, and previous screening history. Not all variables that were significantly different between arms were adjusted for, therefore adjustments for key variables (age, race, literacy) were made in statistical analyses. Other limitations related generalizability of results. Conclusions Although joint breast and colon cancer screening rates were increased substantially over existing baseline rates in all 3 arms, the completion rate for both tests was modest. Nurse support and telephone follow-up were most effective. However, it is not likely to be cost effective or affordable in clinics with limited resources. PMID:26918252
Suba, E J; Nguyen, C H; Nguyen, B D; Raab, S S
2001-03-01
Cervical carcinoma is the leading cause of cancer-related death among women in the developing world. The absence of cervical screening in Vietnam and other developing countries is due in large part to the perceived expense of implementing Papanicolaou cytology screening services, although, to the authors' knowledge, the cost-effectiveness of establishing such services has never been studied in a developing country. Using decision analytic methods, the authors assessed cost-effectiveness of Pap screening from a societal perspective in Vietnam, the world's 9th most populous developing country (estimated 1999 population, 79 million). Outcomes measured included life expectancy, cervical carcinoma incidence, cost per woman, and cost-effectiveness. Total costs to establish a nationwide 5-year interval Pap screening program in Vietnam will average less than $148,400 annually during the 10-year time period assumed necessary to develop the program and may be considerably lower if only high risk geographic areas are targeted. Maintenance costs will average less than $0.092 annually per woman in the target screening population. Assuming 70% program participation, cervical carcinoma incidence will decrease from 26 in 100,000 to 14.8 in 100,000, and cost-effectiveness will be $725 per discounted life-year. Several assumptions used in this analysis constitute biases against the effectiveness of Pap screening, which in reality may be significantly more cost-effective than reported here. Contrary to widespread belief, Pap screening in developing countries such as Vietnam is extraordinarily inexpensive and appears to be cost-effective. Because prospects are uncertain regarding useful alternatives to the Pap test, the evidence-based argument for establishing conventional Pap screening services in developing countries such as Vietnam is compelling. Population-based conventional Pap screening services have been established de novo in Vietnam and are now operational. Copyright 2001 American Cancer Society.
Chatterjee, Kaushik; Lin-Gibson, Sheng; Wallace, William E.; Parekh, Sapun H.; Lee, Young J.; Cicerone, Marcus T.; Young, Marian F.; Simon, Carl G.
2011-01-01
Cells are known to sense and respond to the physical properties of their environment and those of tissue scaffolds. Optimizing these cell-material interactions is critical in tissue engineering. In this work, a simple and inexpensive combinatorial platform was developed to rapidly screen three-dimensional (3D) tissue scaffolds and was applied to screen the effect of scaffold properties for tissue engineering of bone. Differentiation of osteoblasts was examined in poly(ethylene glycol) hydrogel gradients spanning a 30-fold range in compressive modulus (≈ 10 kPa to ≈ 300 kPa). Results demonstrate that material properties (gel stiffness) of scaffolds can be leveraged to induce cell differentiation in 3D culture as an alternative to biochemical cues such as soluble supplements, immobilized biomolecules and vectors, which are often expensive, labile and potentially carcinogenic. Gel moduli of ≈ 225 kPa and higher enhanced osteogenesis. Furthermore, it is proposed that material-induced cell differentiation can be modulated to engineer seamless tissue interfaces between mineralized bone tissue and softer tissues such as ligaments and tendons. This work presents a combinatorial method to screen biological response to 3D hydrogel scaffolds that more closely mimics the 3D environment experienced by cells in vivo. PMID:20378163
Advances in fragment-based drug discovery platforms.
Orita, Masaya; Warizaya, Masaichi; Amano, Yasushi; Ohno, Kazuki; Niimi, Tatsuya
2009-11-01
Fragment-based drug discovery (FBDD) has been established as a powerful alternative and complement to traditional high-throughput screening techniques for identifying drug leads. At present, this technique is widely used among academic groups as well as small biotech and large pharmaceutical companies. In recent years, > 10 new compounds developed with FBDD have entered clinical development, and more and more attention in the drug discovery field is being focused on this technique. Under the FBDD approach, a fragment library of relatively small compounds (molecular mass = 100 - 300 Da) is screened by various methods and the identified fragment hits which normally weakly bind to the target are used as starting points to generate more potent drug leads. Because FBDD is still a relatively new drug discovery technology, further developments and optimizations in screening platforms and fragment exploitation can be expected. This review summarizes recent advances in FBDD platforms and discusses the factors important for the successful application of this technique. Under the FBDD approach, both identifying the starting fragment hit to be developed and generating the drug lead from that starting fragment hit are important. Integration of various techniques, such as computational technology, X-ray crystallography, NMR, surface plasmon resonance, isothermal titration calorimetry, mass spectrometry and high-concentration screening, must be applied in a situation-appropriate manner.
Lam, Carl W; Lim, Seong-Rin; Schoenung, Julie M
2011-05-15
Modern manufacturing of printed wiring boards (PWBs) involves extensive use of various hazardous chemicals in different manufacturing steps such as board preparation, circuit design transfer, etching and plating processes. Two complementary environmental screening methods developed by the U.S. EPA, namely: (i) the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI) and (ii) Risk-Screening Environmental Indicators (RSEI), are used to quantify geographic and chemical environmental impacts in the U.S. PWB manufacturing industry based on Toxics Release Inventory (TRI) data. Although the release weight percentages of industrial chemicals such as methanol, glycol ethers and dimethylformamide comprise the larger fraction of reported air and water emissions, results indicate that lead, copper and their compounds' releases correspond to the highest environmental impact from toxicity potentials and risk-screening scores. Combining these results with further knowledge of PWB manufacturing, select alternative chemical processes and materials for pollution prevention are discussed. Examples of effective pollution prevention options in the PWB industry include spent etchant recovery technologies, and process and material substitutions. In addition, geographic assessment of environmental burden highlights states where promotion of pollution prevention strategies and emissions regulations can have the greatest effect to curb the PWB industry's toxic release impacts. Copyright © 2011 Elsevier B.V. All rights reserved.
Coplanar back contacts for thin silicon solar cells
NASA Technical Reports Server (NTRS)
Thornhill, J. W.; Sipperly, W. E.
1980-01-01
A process for fabricating 2 to 3 mil wraparound solar cells was formulated. Sample thin wraparound cells were fabricated using this process. The process used a reinforced perimeter construction to reduce the breakage that occurs during handling of the wafers. A retracting piston post was designed and fabricated to help minimize the breakage that occurs during the screen printing process. Two alternative methods of applying the aluminum back surface field were investigated. In addition to the standard screen printed back surface field, both spin-on and evaporated aluminum techniques were researched. Neither spin-on nor evaporated aluminum made any noticeable improvement over the screen printing technique. A fine screen mesh was chosen for the application of the aluminum paste back surface field. The optimum time and temperature for firing the aluminum turned out to be thirty seconds at 850 C. The development work on the dielectric included looking at three dielectrics for the wraparound application. Transene 1000, Thick Film Systems 1126RCB and an in house formulation 61-2-2A were all tested. Cells with pre-dielectric thickness of 3.0-0-3.5 mils using Transene 1000 as the wraparound dielectric and the procedure outlined above showed an average efficiency of 10.7 percent. Thinner cells were fabricated, but had an unacceptable yield and efficiency.
Color waveguide transparent screen using lens array holographic optical element
NASA Astrophysics Data System (ADS)
Liu, Siqi; Sun, Peng; Wang, Chang; Zheng, Zhenrong
2017-11-01
A color transparent screen was designed in this paper, a planar glass was used as a waveguide structure and the lens array holographic optical element (HOE) was used as a display unit. The lens array HOE was exposed by two coherent beams. One was the reference wave which directly illuminated on the holographic material and the other was modulated by the micro lens array. The lens array HOE can display the images with see-through abilities. Unlike the conventional lens array HOE, a planar glass was adopted as the waveguide in the experiment. The projecting light was totally internal-reflected in the planar glass to eliminate the undesired zero-order diffracted light. By using waveguide, it also brings advantage of compact structure. Colorful display can be realized in our system as the holographic materials were capable for multi-wavelength display. In this paper, a color transparent screen utilizing the lens array HOE and waveguide were designed. Experiment results showed a circular display area on the transparent screen. The diameter of the area is 20 mm and it achieved the pixel resolution of 100 μm. This simple and effective method could be an alternative in the augment reality (AR) applications, such as transparent phone and television.
NASA Astrophysics Data System (ADS)
Patil, Ajeetkumar; Rao K., Swati; V. K., Unnikrishnan; Pai, Keerthilatha M.; Kartha, V. B.; Chidangil, Santhosh
2017-07-01
Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.
Peter, Jochen F; Otto, Angela M
2010-02-01
The effective isolation and purification of proteins from biological fluids is the most crucial step for a successful protein analysis when only minute amounts are available. While conventional purification methods such as dialysis, ultrafiltration or protein precipitation often lead to a marked loss of protein, SPE with small-sized particles is a powerful alternative. The implementation of particles with superparamagnetic cores facilitates the handling of those particles and allows the application of particles in the nanometer to low micrometer range. Due to the small diameters, magnetic particles are advantageous for increasing sensitivity when using subsequent MS analysis or gel electrophoresis. In the last years, different types of magnetic particles were developed for specific protein purification purposes followed by analysis or screening procedures using MS or SDS gel electrophoresis. In this review, the use of magnetic particles for different applications, such as, the extraction and analysis of DNA/RNA, peptides and proteins, is described.
Tarifa, Anamary; Almirall, José R
2015-05-01
A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (<2min sampling) and high sensitivity capable of detecting 3ng of diphenylamine (DPA) and 8ng of nitroglycerine (NG). Direct analysis of the headspace of over 50 swabs collected from the hands of suspected shooters (and non-shooters) provides information regarding VOCs present on their hands. In addition, a fast laser induced breakdown spectroscopy (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Alternative Fuels Research Laboratory
NASA Technical Reports Server (NTRS)
Surgenor, Angela D.; Klettlinger, Jennifer L.; Nakley, Leah M.; Yen, Chia H.
2012-01-01
NASA Glenn has invested over $1.5 million in engineering, and infrastructure upgrades to renovate an existing test facility at the NASA Glenn Research Center (GRC), which is now being used as an Alternative Fuels Laboratory. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch (F-T) synthesis and thermal stability testing. This effort is supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing project. The purpose of this test facility is to conduct bench scale F-T catalyst screening experiments. These experiments require the use of a synthesis gas feedstock, which will enable the investigation of F-T reaction kinetics, product yields and hydrocarbon distributions. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor for catalyst activation studies. Product gas composition and performance data can be continuously obtained with an automated gas sampling system, which directly connects the reactors to a micro-gas chromatograph (micro GC). Liquid and molten product samples are collected intermittently and are analyzed by injecting as a diluted sample into designated gas chromatograph units. The test facility also has the capability of performing thermal stability experiments of alternative aviation fuels with the use of a Hot Liquid Process Simulator (HLPS) (Ref. 1) in accordance to ASTM D 3241 "Thermal Oxidation Stability of Aviation Fuels" (JFTOT method) (Ref. 2). An Ellipsometer will be used to study fuel fouling thicknesses on heated tubes from the HLPS experiments. A detailed overview of the test facility systems and capabilities are described in this paper.
Bogavac-Stanojević, Natasa; Dopsaj, Violeta; Jelić-Ivanović, Zorana; Lakić, Dragana; Vasić, Dragan; Petrova, Guenka
2013-01-01
We examined the cost-effectiveness of the three different D-dimer measurements in the screening of DVT in models with and without calculation of pre-test probability (PTP) score. Moreover, we calculated the minimal cost in DVT detection. In the group of 192 patients with clinically suspected acute DVT, we examined the three different D-dimer measurements (Innovance D-dimer, Hemosil D-dimer HS and Vidas D-dimer Exclusion II) in combination with and without PTP assessment. The diagnostic alternative employing Vidas D-dimer Exclusion II assay without and with PTP calculation gave lower incremental cost-effectiveness ratio (ICER) than the alternative employing Hemosil D-dimer HS assay (0.187 Euros vs. 0.998 Euros per one additional DVT positive patient selected for CUS in model without PTP assessment and 0.450 vs. 0.753 Euros per one DVT positive patient selected for CUS in model with PTP assessment). According to sensitivity analysis, the Hemosil D-dimer HS assay was the most cost effective alternative when one patient was admitted to the vascular ambulance per day. Vidas D-dimer Exclusion II assay was the most cost effective alternative when more than one patient were admitted to the vascular ambulance per day. Cost minimisation analysis indicated that selection of patients according to PTP score followed by D-dimer analysis decreases the cost of DVT diagnosis. ICER analysis enables laboratories to choose optimal laboratory tests according to number of patients admitted to laboratory. Results support the feasibility of using PTP scoring and D-dimer measurement before CUS examination in DVT screening.
Power Enhancement in High Dimensional Cross-Sectional Tests
Fan, Jianqing; Liao, Yuan; Yao, Jiawei
2016-01-01
We propose a novel technique to boost the power of testing a high-dimensional vector H : θ = 0 against sparse alternatives where the null hypothesis is violated only by a couple of components. Existing tests based on quadratic forms such as the Wald statistic often suffer from low powers due to the accumulation of errors in estimating high-dimensional parameters. More powerful tests for sparse alternatives such as thresholding and extreme-value tests, on the other hand, require either stringent conditions or bootstrap to derive the null distribution and often suffer from size distortions due to the slow convergence. Based on a screening technique, we introduce a “power enhancement component”, which is zero under the null hypothesis with high probability, but diverges quickly under sparse alternatives. The proposed test statistic combines the power enhancement component with an asymptotically pivotal statistic, and strengthens the power under sparse alternatives. The null distribution does not require stringent regularity conditions, and is completely determined by that of the pivotal statistic. As specific applications, the proposed methods are applied to testing the factor pricing models and validating the cross-sectional independence in panel data models. PMID:26778846
Simple method to distinguish between primary and secondary C3 deficiencies.
Pereira de Carvalho Florido, Marlene; Ferreira de Paula, Patrícia; Isaac, Lourdes
2003-03-01
Due to the increasing numbers of reported clinical cases of complement deficiency in medical centers, clinicians are now more aware of the role of the complement system in the protection against infections caused by microorganisms. Therefore, clinical laboratories are now prepared to perform a number of diagnostic tests of the complement system other than the standard 50% hemolytic component assay. Deficiencies of alternative complement pathway proteins are related to severe and recurrent infections; and the application of easy, reliable, and low-cost methods for their detection and distinction are always welcome, notably in developing countries. When activation of the alternative complement pathway is evaluated in hemolytic agarose plates, some but not all human sera cross-react to form a late linear lysis. Since the formation of this linear lysis is dependent on C3 and factor B, it is possible to use late linear lysis to routinely screen for the presence of deficiencies of alternative human complement pathway proteins such as factor B. Furthermore, since linear lysis is observed between normal human serum and primary C3-deficient serum but not between normal human serum and secondary C3-deficient serum caused by the lack of factor H or factor I, this assay may also be used to discriminate between primary and secondary C3 deficiencies.
Rockers, Peter C.; Bonawitz, Rachael; Sriruttan, Charlotte; Glencross, Deborah K.; Cassim, Naseem; Coetzee, Lindi M.; Greene, Gregory S.; Chiller, Tom M.; Vallabhaneni, Snigdha; Long, Lawrence; van Rensburg, Craig; Govender, Nelesh P.
2016-01-01
Background In 2015 South Africa established a national cryptococcal antigenemia (CrAg) screening policy targeted at HIV-infected patients with CD4+ T-lymphocyte (CD4) counts <100 cells/ μl who are not yet on antiretroviral treatment (ART). Two screening strategies are included in national guidelines: reflex screening, where a CrAg test is performed on remnant blood samples from CD4 testing; and provider-initiated screening, where providers order a CrAg test after a patient returns for CD4 test results. The objective of this study was to compare costs and effectiveness of these two screening strategies. Methods We developed a decision analytic model to compare reflex and provider-initiated screening in terms of programmatic and health outcomes (number screened, number identified for preemptive treatment, lives saved, and discounted years of life saved) and screening and treatment costs (2015 USD). We estimated a base case with prevalence and other parameters based on data collected during CrAg screening pilot projects integrated into routine HIV care in Gauteng, Free State, and Western Cape Provinces. We conducted sensitivity analyses to explore how results change with underlying parameter assumptions. Results In the base case, for each 100,000 CD4 tests, the reflex strategy compared to the provider-initiated strategy has higher screening costs ($37,536 higher) but lower treatment costs ($55,165 lower), so overall costs of screening and treatment are $17,629 less with the reflex strategy. The reflex strategy saves more lives (30 lives, 647 additional years of life saved). Sensitivity analyses suggest that reflex screening dominates provider-initiated screening (lower total costs and more lives saved) or saves additional lives for small additional costs (< $125 per life year) across a wide range of conditions (CrAg prevalence, patient and provider behavior, patient survival without treatment, and effectiveness of preemptive fluconazole treatment). Conclusions In countries with substantial numbers of people with untreated, advanced HIV disease such as South Africa, CrAg screening before initiation of ART has the potential to reduce cryptococcal meningitis and save lives. Reflex screening compared to provider-initiated screening saves more lives and is likely to be cost saving or have low additional costs per additional year of life saved. PMID:27390864
Screening methods for post-stroke visual impairment: a systematic review.
Hanna, Kerry Louise; Hepworth, Lauren Rachel; Rowe, Fiona
2017-12-01
To provide a systematic overview of the various tools available to screen for post-stroke visual impairment. A review of the literature was conducted including randomised controlled trials, controlled trials, cohort studies, observational studies, systematic reviews and retrospective medical note reviews. All languages were included and translation was obtained. Participants included adults ≥18 years old diagnosed with a visual impairment as a direct cause of a stroke. We searched a broad range of scholarly online resources and hand-searched articles registers of published, unpublished and on-going trials. Search terms included a variety of MESH terms and alternatives in relation to stroke and visual conditions. Study selection was performed by two authors independently. The quality of the evidence and risk of bias were assessed using the STROBE, GRACE and PRISMA statements. A total of 25 articles (n = 2924) were included in this review. Articles appraised reported on tools screening solely for visual impairments or for general post-stroke disabilities inclusive of vision. The majority of identified tools screen for visual perception including visual neglect (VN), with few screening for visual acuity (VA), visual field (VF) loss or ocular motility (OM) defects. Six articles reported on nine screening tools which combined visual screening assessment alongside screening for general stroke disabilities. Of these, three included screening for VA; three screened for VF loss; three screened for OM defects and all screened for VN. Two tools screened for all visual impairments. A further 19 articles were found which reported on individual vision screening tests in stroke populations; two for VF loss; 11 for VN and six for other visual perceptual defects. Most tools cannot accurately account for those with aphasia or communicative deficits, which are common problems following a stroke. There is currently no standardised visual screening tool which can accurately assess all potential post-stroke visual impairments. The current tools screen for only a number of potential stroke-related impairments, which means many visual defects may be missed. The sensitivity of those which screen for all impairments is significantly lowered when patients are unable to report their visual symptoms. Future research is required to develop a tool capable of assessing stroke patients which encompasses all potential visual deficits and can also be easily performed by both the patients and administered by health care professionals in order to ensure all stroke survivors with visual impairment are accurately identified and managed. Implications for Rehabilitation Over 65% of stroke survivors will suffer from a visual impairment, whereas 45% of stroke units do not assess vision. Visual impairment significantly reduces the quality of life, such as being unable to return to work, driving and depression. This review outlines the available screening methods to accurately identify stroke survivors with visual impairments. Identifying visual impairment after stroke can aid general rehabilitation and thus, improve the quality of life for these patients.
Aponte-González, Johanna; Fajardo-Bernal, Luisa; Diaz, Jorge; Eslava-Schmalbach, Javier; Gamboa, Oscar; Hay, Joel W.
2013-01-01
Objective To compare costs and effectiveness of three strategies used against cervical cancer (CC) and genital warts: (i) Screening for CC; (ii) Bivalent Human Papillomavirus (HPV) 16/18 vaccine added to screening; (iii) Quadrivalent HPV 6/11/16/18 vaccine added to screening. Methods A Markov model was designed in order to simulate the natural history of the disease from 12 years of age (vaccination) until death. Transition probabilities were selected or adjusted to match the HPV infection profile in Colombia. A systematic review was undertaken in order to derive efficacy values for the two vaccines as well as for the operational characteristics of the cytology test. The societal perspective was used. Effectiveness was measured in number of averted Disability Adjusted Life Years (DALYS). Results At commercial prices reported for 2010 the two vaccines were shown to be non-cost-effective alternatives when compared with the existing screening strategy. Sensitivity analyses showed that results are affected by the cost of vaccines and their efficacy values, making it difficult to determine with certainty which of the two vaccines has the best cost-effectiveness profile. To be ‘cost-effective’ vaccines should cost between 141 and 147 USD (Unite States Dollars) per vaccinated girl at the most. But at lower prices such as those recommended by WHO or the price of other vaccines in Colombia, HPV vaccination could be considered very cost-effective. Conclusions HPV vaccination could be a convenient alternative for the prevention of CC in Colombia. However, the price of the vaccine should be lower for this vaccination strategy to be cost-effective. It is also important to take into consideration the willingness to pay, budgetary impact, and program implications, in order to determine the relevance of a vaccination program in this country, as well as which vaccine should be selected for use in the program. PMID:24260441
Nel, Andre E.; Nasser, Elina; Godwin, Hilary; Avery, David; Bahadori, Tina; Bergeson, Lynn; Beryt, Elizabeth; Bonner, James C.; Boverhof, Darrell; Carter, Janet; Castranova, Vince; DeShazo, J. R.; Hussain, Saber M.; Kane, Agnes B.; Klaessig, Fred; Kuempel, Eileen; Lafranconi, Mark; Landsiedel, Robert; Malloy, Timothy; Miller, Mary Beth; Morris, Jeffery; Moss, Kenneth; Oberdorster, Gunter; Pinkerton, Kent; Pleus, Richard C.; Shatkin, Jo Anne; Thomas, Rusty; Tolaymat, Thabet; Wang, Amy; Wong, Jeffrey
2014-01-01
There has been a conceptual shift in toxicological studies from describing what happens to explaining how the adverse outcome occurs, thereby enabling a deeper and improved understanding of how biomolecular and mechanistic profiling can inform hazard identification and improve risk assessment. Compared to traditional toxicology methods, which have a heavy reliance on animals, new approaches to generate toxicological data are becoming available for the safety assessment of chemicals, including high-throughput and high-content screening (HTS, HCS). With the emergence of nanotechnology, the exponential increase in the total number of engineered nanomaterials (ENMs) in research, development, and commercialization requires a robust scientific approach to screen ENM safety in humans and the environment rapidly and efficiently. Spurred by the developments in chemical testing, a promising new toxicological paradigm for ENMs is to use alternative test strategies (ATS), which reduce reliance on animal testing through the use of in vitro and in silico methods such as HTS, HCS, and computational modeling. Furthermore, this allows for the comparative analysis of large numbers of ENMs simultaneously and for hazard assessment at various stages of the product development process and overall life cycle. Using carbon nanotubes as a case study, a workshop bringing together national and international leaders from government, industry, and academia was convened at the University of California, Los Angeles to discuss the utility of ATS for decision-making analyses of ENMs. After lively discussions, a short list of generally shared viewpoints on this topic was generated, including a general view that ATS approaches for ENMs can significantly benefit chemical safety analysis. PMID:23924032
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
...We, the U.S. Fish and Wildlife Service (Service) and the California Department of Fish and Wildlife (CDFW), announce that the record of decision (ROD) for the Llano Seco Riparian Sanctuary Unit Restoration and Princeton, Codora, Glenn & Provident Irrigation Districts (PCGID-PID) Pumping Plan/Fish Screen Facility Protection Project is now available. The ROD includes a statement of the decisions made, the basis for the decisions, a description of the alternative considered, a description of the environmentally preferable alternative, an overview of the measures to minimize environmental impacts, and a summary of public involvement in the decision-making process.
An end-point method based on graphene oxide for RNase H analysis and inhibitors screening.
Zhao, Chuan; Fan, Jialong; Peng, Lan; Zhao, Lijian; Tong, Chunyi; Wang, Wei; Liu, Bin
2017-04-15
As a highly conserved damage repair protein, RNase H can hydrolysis DNA-RNA heteroduplex endonucleolytically and cleave RNA-DNA junctions as well. In this study, we have developed an accurate and sensitive RNase H assay based on fluorophore-labeled chimeric substrate hydrolysis and the differential affinity of graphene oxide on RNA strand with different length. This end-point measurement method can detect RNase H in a range of 0.01 to 1 units /mL with a detection limit of 5.0×10 -3 units/ mL under optimal conditions. We demonstrate the utility of the assay by screening antibiotics, resulting in the identification of gentamycin, streptomycin and kanamycin as inhibitors with IC 50 of 60±5µM, 70±8µM and 300±20µM, respectively. Furthermore, the assay was reliably used to detect RNase H in complicated biosamples and found that RNase H activity in tumor cells was inhibited by gentamycin and streptomycin sulfate in a concentration-dependent manner. The average level of RNase H in serums of HBV infection group was similar to that of control group. In summary, the assay provides an alternative tool for biochemical analysis for this enzyme and indicates the feasibility of high throughput screening inhibitors of RNase H in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.
High-Resolution Melt Analysis for Rapid Comparison of Bacterial Community Compositions
Hjelmsø, Mathis Hjort; Hansen, Lars Hestbjerg; Bælum, Jacob; Feld, Louise; Holben, William E.
2014-01-01
In the study of bacterial community composition, 16S rRNA gene amplicon sequencing is today among the preferred methods of analysis. The cost of nucleotide sequence analysis, including requisite computational and bioinformatic steps, however, takes up a large part of many research budgets. High-resolution melt (HRM) analysis is the study of the melt behavior of specific PCR products. Here we describe a novel high-throughput approach in which we used HRM analysis targeting the 16S rRNA gene to rapidly screen multiple complex samples for differences in bacterial community composition. We hypothesized that HRM analysis of amplified 16S rRNA genes from a soil ecosystem could be used as a screening tool to identify changes in bacterial community structure. This hypothesis was tested using a soil microcosm setup exposed to a total of six treatments representing different combinations of pesticide and fertilization treatments. The HRM analysis identified a shift in the bacterial community composition in two of the treatments, both including the soil fumigant Basamid GR. These results were confirmed with both denaturing gradient gel electrophoresis (DGGE) analysis and 454-based 16S rRNA gene amplicon sequencing. HRM analysis was shown to be a fast, high-throughput technique that can serve as an effective alternative to gel-based screening methods to monitor microbial community composition. PMID:24610853
Stadlmair, Lara F; Letzel, Thomas; Drewes, Jörg E; Grassmann, Johanna
2018-08-01
At present, the removal of trace organic chemicals such as pharmaceuticals in wastewater treatment plants is often incomplete resulting in a continuous discharge into the aqueous environment. To overcome this issue, bioremediation approaches gained significant importance in recent times, since they might have a lower carbon footprint than chemical or physical treatment methods. In this context, enzyme-based technologies represent a promising alternative since they are able to specifically target certain chemicals. For this purpose, versatile monitoring of enzymatic reactions is of great importance in order to understand underlying transformation mechanisms and estimate the suitability of various enzymes exhibiting different specificities for bioremediation purposes. This study provides a comprehensive review, summarizing research on enzymatic transformation of pharmaceuticals in water treatment applications using traditional and state-of-the-art enzyme screening approaches with a special focus on mass spectrometry (MS)-based and high-throughput tools. MS-based enzyme screening represents an approach that allows a comprehensive mechanistic understanding of enzymatic reactions and, in particular, the identification of transformation products. A critical discussion of these approaches for implementation in wastewater treatment processes is also presented. So far, there are still major gaps between laboratory- and field-scale research that need to be overcome in order to assess the viability for real applications. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vegetation sampling for the screening of subsurface pollution
NASA Astrophysics Data System (ADS)
Karlson, U. G.; Petersen, M. D.; Algreen, M.; Rein, A.; Sheehan, E.; Limmer, M. A.; Burken, J. G.; Mayer, P.; Trapp, S.
2012-04-01
Measurement of vegetation samples has been reported as an alternative, cheap method to drilling for exploring subsurface pollution. The purpose of this presentation is to give an update on some further developments of this field method - faster sampling and improved analysis for chlorinated solvents, and application of phytomonitoring to heavy metal contamination. Rapid analysis of trees for chlorinated solvents was facilitated by employing automated headspace SPME-GC/ECD, resulting in a detection limit of 0.87 and 0.04 μg/kg fresh weight of wood for TCE and PCE, respectively, which is significantly lower than we have reported earlier, using manual injection of 1mL headspace air into a GC/MS. Technical details of the new method will be presented. As an even more direct alternative, time weighted average SPME analysis has been developed for in planta sampling of trees, using novel polydimethylsiloxane/carboxen SPME fibres designed for field application. In a different study, trees growing on a former dump site in Norway were analyzed for arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), and zinc (Zn). Concentrations in wood were in averages (dw) 30 mg/kg for Zn, 2 mg/kg for Cu, and <1 mg/kg for Cd, Cr, As and Ni. For all except one case, mean concentrations from the dump site were higher than those from a unpolluted reference site, but the difference was small and not always significant. Differences between tree species were typically higher than differences between the polluted and the unpolluted site. As all these elements occur naturally, and Cu, Ni, and Zn are essential elements, all trees will have a natural background of these elements, and the occurrence alone does not indicate soil pollution. For the interpretation of the results, a comparison to wood samples from an unpolluted reference site with the same tree species and similar soil conditions is required. This makes the tree core screening method less reliable for heavy metals than, e.g., for chlorinated solvents.
Álvarez, Daniel; Alonso-Álvarez, María L.; Gutiérrez-Tobal, Gonzalo C.; Crespo, Andrea; Kheirandish-Gozal, Leila; Hornero, Roberto; Gozal, David; Terán-Santos, Joaquín; Del Campo, Félix
2017-01-01
Study Objectives: Nocturnal oximetry has become known as a simple, readily available, and potentially useful diagnostic tool of childhood obstructive sleep apnea (OSA). However, at-home respiratory polygraphy (HRP) remains the preferred alternative to polysomnography (PSG) in unattended settings. The aim of this study was twofold: (1) to design and assess a novel methodology for pediatric OSA screening based on automated analysis of at-home oxyhemoglobin saturation (SpO2), and (2) to compare its diagnostic performance with HRP. Methods: SpO2 recordings were parameterized by means of time, frequency, and conventional oximetric measures. Logistic regression models were optimized using genetic algorithms (GAs) for three cutoffs for OSA: 1, 3, and 5 events/h. The diagnostic performance of logistic regression models, manual obstructive apnea-hypopnea index (OAHI) from HRP, and the conventional oxygen desaturation index ≥ 3% (ODI3) were assessed. Results: For a cutoff of 1 event/h, the optimal logistic regression model significantly outperformed both conventional HRP-derived ODI3 and OAHI: 85.5% accuracy (HRP 74.6%; ODI3 65.9%) and 0.97 area under the receiver operating characteristics curve (AUC) (HRP 0.78; ODI3 0.75) were reached. For a cutoff of 3 events/h, the logistic regression model achieved 83.4% accuracy (HRP 85.0%; ODI3 74.5%) and 0.96 AUC (HRP 0.93; ODI3 0.85) whereas using a cutoff of 5 events/h, oximetry reached 82.8% accuracy (HRP 85.1%; ODI3 76.7) and 0.97 AUC (HRP 0.95; ODI3 0.84). Conclusions: Automated analysis of at-home SpO2 recordings provide accurate detection of children with high pretest probability of OSA. Thus, unsupervised nocturnal oximetry may enable a simple and effective alternative to HRP and PSG in unattended settings. Citation: Álvarez D, Alonso-Álvarez ML, Gutiérrez-Tobal GC, Crespo A, Kheirandish-Gozal L, Hornero R, Gozal D, Terán-Santos J, Del Campo F. Automated screening of children with obstructive sleep apnea using nocturnal oximetry: an alternative to respiratory polygraphy in unattended settings. J Clin Sleep Med. 2017;13(5):693–702. PMID:28356177
Penaranda, Eribeth; Molokwu, Jennifer; Hernandez, Ingrid; Salaiz, Rebekah; Nguyen, Norma; Byrd, Theresa; Shokar, Navkiran
2014-07-01
Hispanic women living along the US border with Mexico have one of the highest cervical cancer mortality rates in the nation, owing in part to lower rates of screening. The barriers to screening in this population include lack of access to care and fear of and embarrassment about the pelvic examination. Screening for oncogenic or high-risk human papillomavirus during cervical cytology has been added to screening recommendations. A novel method for human papillomavirus testing is self-sampling, in which women collect their own cervicovaginal samples. There is lack of information about the acceptability of self-sampling as an alternative to cytology for cervical cancer screening in women living along the US-Mexico border. We conducted five focus groups with women between the ages of 30 and 65 who were primary care patients of clinics along the US-Mexico border. We used constructs from different health behavioral theories as a framework for the interview guide. A total of 21 women participated in the focus groups, 80% of whom were Hispanic; mean age was 53.4 (standard deviation 7.9). More than one-third (38%) of the participants had not undergone a Papanicolaou test in the last 3 years. Women identified the perceived benefits of self-sampling as ease, convenience, practicability, less embarrassment, and need for child care as compared with a Papanicolaou test. The main barrier to self-sampling was concern about not performing the test correctly. In this qualitative study, we found positive attitudes toward self-sampling among women living along the US border with Mexico. Further research is needed to evaluate interventions that address women's low levels of self-efficacy to perform the test and to evaluate the effectiveness of self-sampling in increasing cervical cancer screening rates.
Telehealth Measures Screening for Developmental Language Disorders in Spanish-Speaking Toddlers
2016-01-01
Abstract Background: This is the second of two studies that described the use of telehealth language screening measures for use with young Spanish-speaking children. Introduction: The purpose of this study was to describe the classification accuracy of individual telehealth language screening measures as well as the accuracy of combinations of measures used with Spanish-speaking toddler-age children from rural and underserved areas of the country. Materials and Methods: This study applied an asynchronous hybrid telehealth approach that implemented parent-structured play activities with a standard set of stimuli, and interaction with a My First Words e-book. These interactions were recorded with a mini camcorder. In addition, a traditional pen and paper parent questionnaire measure was collected. Sixty-two mostly Spanish-speaking preschool-age children and their parents participated. Twenty-two children had developmental language disorders (DLDs) and 40 had typical language development. Results: Although several of the individual measures were significantly and strongly associated with standardized language scores, only reported vocabulary had classification accuracy values that were desirable for screening for DLDs. An improvement was observed when reported vocabulary was combined with a number of different words children produced during interactions with parents. Conclusions: This research provides additional evidence showing the effectiveness of a hybrid telehealth model in screening the language development of Spanish-speaking children. More specifically, reported vocabulary combined with number of different words produced by a child can provide informative and accurate diagnostic information when screening Spanish-speaking toddler-age children for DLDs. These findings replicate the first study in showing that hybrid telehealth approaches that combine the use of video technology and traditional pen and paper surveys yield strong results, and may be a viable screening alternative when face-to-face access to a bilingual provider is not possible. PMID:26982548
Estai, Mohamed; Kanagasingam, Yogesan; Xiao, Di; Vignarajan, Janardhan; Huang, Boyan; Kruger, Estie; Tennant, Marc
2016-09-01
It is widely considered that telemedicine can make positive contributions to dental practice. This study aimed to evaluate a cloud-based telemedicine application for screening for oral diseases. A telemedicine system, based on a store-and-forward method, was developed to work as a platform for data storage. An Android application was developed to facilitate entering demographic details and capturing oral photos. As a proof-of-concept, six volunteers were enrolled in a trial to obtain oral images using smartphone cameras. Following an onsite oral examination, images of participants' teeth were obtained by a trained dental assistant. Oral images were directly uploaded from the smartphone to a cloud-based server via broadband network. The assessments of oral images by offsite dentists were compared with those carried out via face-to-face oral examinations. A complete set of 30 oral images was obtained from all six participants. Out of 192 teeth reviewed, the proportion of ungradable teeth was 8%. Sensitivity and specificity of teledental screening were 57% and 100% respectively. The inter-grader agreement estimated for two examination modalities and between two teledental graders was 70% and 62% respectively. Findings indicate that the proposed system for screening of oral diseases can be implemented to provide a valid and reliable alternative to traditional oral screening. This study provided evidence that a robust system for store-and-forward screening for dental problems can be developed, and leads to the need for further testing of its robustness to confirm the accuracy and reliability of the teledentistry system. © The Author(s) 2015.
A Targeted Approach for Congenital Cytomegalovirus Screening Within Newborn Hearing Screening
McCollister, Faye P.; Sabo, Diane L.; Shoup, Angela G.; Owen, Kris E.; Woodruff, Julie L.; Cox, Edith; Mohamed, Lisa S.; Choo, Daniel I.; Boppana, Suresh B.
2017-01-01
BACKGROUND AND OBJECTIVE: Congenital cytomegalovirus (cCMV) infection remains a leading cause of childhood hearing loss. Currently universal CMV screening at birth does not exist in the United States. An alternative approach could be testing infants who do not pass their newborn hearing screening (NHS) for cCMV. This study was undertaken to evaluate whether a targeted approach will identify infants with CMV-related sensorineural hearing loss (SNHL). METHODS: Infants born at 7 US medical centers received NHS and were also screened for cCMV while in the newborn nursery. Infants who tested positive for CMV received further diagnostic audiologic evaluations to identify or confirm hearing loss. RESULTS: Between 2007 and 2012, 99 945 newborns were screened for both hearing impairment and cCMV. Overall, 7.0% of CMV-positive infants did not pass NHS compared with 0.9% of CMV-negative infants (P < .0001). Among the cCMV infants who failed NHS, diagnostic testing confirmed that 65% had SNHL. In addition, 3.6% of CMV-infected infants who passed their NHS had SNHL confirmed by further evaluation during early infancy. NHS in this cohort identified 57% of all CMV-related SNHL that occurred in the neonatal period. CONCLUSIONS: A targeted CMV approach that tests newborns who fail their NHS identified the majority of infants with CMV-related SNHL at birth. However, 43% of the infants with CMV-related SNHL in the neonatal period and cCMV infants who are at risk for late onset SNHL were not identified by NHS. PMID:28049114
Hewetson, Michael; Sykes, Ben William; Hallowell, Gayle Davina; Tulamo, Riitta-Mari
2017-03-11
Equine gastric ulcer syndrome (EGUS) is common in adult horses, particularly those involved in performance disciplines. Currently, detection of EGUS by gastroscopy is the only reliable ante mortem method for definitive diagnosis; however it is unsuitable as a screening test because it is expensive, time consuming, and is not readily available to most veterinarians. Sucrose permeability testing represents a simple, economical alternative to gastroscopy for screening purposes, and the feasibility of this approach in the horse has been previously reported. The aim of this study was to determine the diagnostic accuracy of blood sucrose as a screening test for EGUS in a large group of adult horses with and without naturally occurring gastric disease. One hundred and one adult horses with or without naturally occurring gastric ulceration were studied. The diagnostic accuracy of blood sucrose for diagnosis of gastric lesions (GL), glandular lesions (GDL), squamous lesions (SQL), and clinically significant lesions (CSL) at 45 and 90 min after administration of 1 g/kg of sucrose via nasogastric intubation was assessed using receiver operator characteristics (ROC) curves and calculating the area under the curve (AUC). For each lesion type, sucrose concentration in blood was compared to gastroscopy, as the gold standard, and sensitivities (Se) and specificities (Sp) were calculated across a range of sucrose concentrations. Ulcer grading was performed blindly by one observer; and the results were validated by comparing them with that of two other observers, and calculating the level of agreement. Cut-off values were selected manually to optimize Se. The prevalence of GL, GDL, SQL, and CSL was 83, 70, 53 and 58% respectively. At the selected cut-offs, Se ranged from 51 to 79% and Sp ranged from 43 to 72%, depending upon the lesion type and time of sampling. Blood sucrose is neither a sensitive or specific test for detecting EGUS in this population of adult horses with naturally occurring gastric ulceration. Further studies aimed at evaluating the performance characteristics of the test in different study populations are warranted. Given the limitations of endoscopy, due consideration should also be given to alternative methods for comparison of blood sucrose with a gold standard.
Multiplexed transcriptome analysis to detect ALK, ROS1 and RET rearrangements in lung cancer
Rogers, Toni-Maree; Arnau, Gisela Mir; Ryland, Georgina L.; Huang, Stephen; Lira, Maruja E.; Emmanuel, Yvette; Perez, Omar D.; Irwin, Darryl; Fellowes, Andrew P.; Wong, Stephen Q.; Fox, Stephen B.
2017-01-01
ALK, ROS1 and RET gene fusions are important predictive biomarkers for tyrosine kinase inhibitors in lung cancer. Currently, the gold standard method for gene fusion detection is Fluorescence In Situ Hybridization (FISH) and while highly sensitive and specific, it is also labour intensive, subjective in analysis, and unable to screen a large numbers of gene fusions. Recent developments in high-throughput transcriptome-based methods may provide a suitable alternative to FISH as they are compatible with multiplexing and diagnostic workflows. However, the concordance between these different methods compared with FISH has not been evaluated. In this study we compared the results from three transcriptome-based platforms (Nanostring Elements, Agena LungFusion panel and ThermoFisher NGS fusion panel) to those obtained from ALK, ROS1 and RET FISH on 51 clinical specimens. Overall agreement of results ranged from 86–96% depending on the platform used. While all platforms were highly sensitive, both the Agena panel and Thermo Fisher NGS fusion panel reported minor fusions that were not detectable by FISH. Our proof–of–principle study illustrates that transcriptome-based analyses are sensitive and robust methods for detecting actionable gene fusions in lung cancer and could provide a robust alternative to FISH testing in the diagnostic setting. PMID:28181564
Bannon, Catherine C; Campbell, Douglas A
2017-01-01
Diatoms are marine primary producers that sink in part due to the density of their silica frustules. Sinking of these phytoplankters is crucial for both the biological pump that sequesters carbon to the deep ocean and for the life strategy of the organism. Sinking rates have been previously measured through settling columns, or with fluorimeters or video microscopy arranged perpendicularly to the direction of sinking. These side-view techniques require large volumes of culture, specialized equipment and are difficult to scale up to multiple simultaneous measures for screening. We established a method for parallel, large scale analysis of multiple phytoplankton sinking rates through top-view monitoring of chlorophyll a fluorescence in microtitre well plates. We verified the method through experimental analysis of known factors that influence sinking rates, including exponential versus stationary growth phase in species of different cell sizes; Thalassiosira pseudonana CCMP1335, chain-forming Skeletonema marinoi RO5A and Coscinodiscus radiatus CCMP312. We fit decay curves to an algebraic transform of the decrease in fluorescence signal as cells sank away from the fluorometer detector, and then used minimal mechanistic assumptions to extract a sinking rate (m d-1) using an RStudio script, SinkWORX. We thereby detected significant differences in sinking rates as larger diatom cells sank faster than smaller cells, and cultures in stationary phase sank faster than those in exponential phase. Our sinking rate estimates accord well with literature values from previously established methods. This well plate-based method can operate as a high throughput integrative phenotypic screen for factors that influence sinking rates including macromolecular allocations, nutrient availability or uptake rates, chain-length or cell size, degree of silification and progression through growth stages. Alternately the approach can be used to phenomically screen libraries of mutants.
Ambrus, A; Füzesi, I; Susán, M; Dobi, D; Lantos, J; Zakar, F; Korsós, I; Oláh, J; Beke, B B; Katavics, L
2005-01-01
This paper reports the results of studies performed to investigate the potential of applying thin layer chromatography (TLC) detection in combination with selected extraction and cleanup methods, for providing an alternative cost-effective analytical procedure for screening and confirmation of pesticide residues in plant commodities. The extraction was carried out with ethyl acetate and an on-line extraction method applying an acetone-dichloromethane mixture. The extracts were cleaned up with SX-3 gel, an adsorbent mixture of active carbon, magnesia, and diatomaceous earth, and on silica micro cartridges. The Rf values of 118 pesticides were tested in eleven elution systems with UV, and eight biotest methods and chemical detection reagents. Cabbage, green peas, orange, and tomatoes were selected as representative sample matrices for fruits and vegetables, while maize, rice, and wheat represented cereal grains. As an internal quality control measure, marker compounds were applied on each plate to verify the proper elution and detection conditions. The Rf values varied in the different elution systems. The best separation (widest Rf range) was achieved with silica gel (SG)--ethyl acetate (0.05-0.7), SG--benzene, (0.02-0.7) and reverse phase RP-18 F-254S layer with acetone: methanol: water/30:30:30 (v/v) (0.1-0.8). The relative standard deviation of Rf values (CV(Rf)) within laboratory reproducibility was generally less than 20%, except below 0.2 Rf, where the CVRf rapidly increased with decreasing Rf values. The fungi spore inhibition, chloroplast inhibition, and enzyme inhibition were found most suitable for detection of pesticides primarily for confirming their identity or screening for known substances. Their use for determination of pesticide residues in samples of unknown origin is not recommended.
Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.
Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil
2016-11-01
Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ahern, C H; Shih, Y-C T; Dong, W; Parmigiani, G; Shen, Y
2014-10-14
Magnetic resonance imaging (MRI) is recommended for women at high risk for breast cancer. We evaluated the cost-effectiveness of alternative screening strategies involving MRI. Using a microsimulation model, we generated life histories under different risk profiles, and assessed the impact of screening on quality-adjusted life-years, and lifetime costs, both discounted at 3%. We compared 12 screening strategies combining annual or biennial MRI with mammography and clinical breast examination (CBE) in intervals of 0.5, 1, or 2 years vs without, and reported incremental cost-effectiveness ratios (ICERs). Based on an ICER threshold of $100,000/QALY, the most cost-effective strategy for women at 25% lifetime risk was to stagger MRI and mammography plus CBE every year from age 30 to 74, yielding ICER $58,400 (compared to biennial MRI alone). At 50% lifetime risk and with 70% reduction in MRI cost, the recommended strategy was to stagger MRI and mammography plus CBE every 6 months (ICER=$84,400). At 75% lifetime risk, the recommended strategy is biennial MRI combined with mammography plus CBE every 6 months (ICER=$62,800). The high costs of MRI and its lower specificity are limiting factors for annual screening schedule of MRI, except for women at sufficiently high risk.
Plumb, Andrew A; Ghanouni, Alex; Rainbow, Sandra; Djedovic, Natasha; Marshall, Sarah; Stein, Judith; Taylor, Stuart A; Halligan, Steve; Lyratzopoulos, Georgios; von Wagner, Christian
2017-03-01
Background Screening participants with abnormal faecal occult blood test results who do not attend further testing are at high risk of colorectal cancer, yet little is known about their reasons for non-attendance. Methods We conducted a medical record review of 170 patients from two English Bowel Cancer Screening Programme centres who had abnormal guaiac faecal occult blood test screening tests between November 2011 and April 2013 but did not undergo colonoscopy. Using information from patient records, we coded and categorized reasons for non-attendance. Results Of the 170 patients, 82 were eligible for review, of whom 66 had at least one recorded reason for lack of colonoscopy follow-up. Reasons fell into seven main categories: (i) other commitments, (ii) unwillingness to have the test, (iii) a feeling that the faecal occult blood test result was a false positive, (iv) another health issue taking priority, (v) failing to complete bowel preparation, (vi) practical barriers (e.g. lack of transport), and (vii) having had or planning colonoscopy elsewhere. The most common single reasons were unwillingness to have a colonoscopy and being away. Conclusions We identify a range of apparent reasons for colonoscopy non-attendance after a positive faecal occult blood test screening. Education regarding the interpretation of guaiac faecal occult blood test findings, offer of alternative confirmatory test options, and flexibility in the timing or location of subsequent testing might decrease non-attendance of diagnostic testing following positive faecal occult blood test.
2013-01-01
Background Our aim is to provide a state-of-the-art overview of knowledge on sex (biological) and gender (sociocultural) aspects of Human papillomavirus (HPV) and cervical cancer for educational purposes. Considerable disparities exist in cervical cancer incidences between different subgroups of women. We provide an outline on the crucial issues and debates based on the recent literature published in leading gender medicine journals. Intersectionality was applied in order to help categorise the knowledge. Methods Key terms (HPV, cervical cancer) were screened in Gender Medicine, Journal of Women’s Health and Women & Health from January 2005-June 2012. Additional searches were conducted for topics insufficiently mentioned, such as HPV vaccination of boys. In total, 71 publications were included (56 original papers, four reviews, six reports, three commentaries, one editorial and one policy statement). Results Research reveals complexity in the way various subgroups of women adhere to cervical screening. Less educated women, older women, uninsured women, homeless women, migrant women facing language barriers, women who have sex with women and obese women participate in Pap smears less frequently. A series of barriers can act to impede decisions to vaccinate against HPV. Conclusions Both male and female controlled preventive methods and treatment measures should be developed in order to tackle HPV infection and different strategies are needed for different subgroups. A substantial discussion and research on alternative methods of prevention was and is lacking. In future research, sex and gender aspects of HPV-related diseases of boys and men as well as subgroup differences in HPV risk need to be addressed. PMID:23394214
NASA Technical Reports Server (NTRS)
Kennedy, Robert S.; Lane, Norman E.; Kuntz, Lois A.
1987-01-01
Surrogate measures are proposed as an alternative to direct assessment of operational performance for purposes of screening agents who may have to work under unusual stresses or in exotic environments. Such measures are particularly proposed when the surrogate can be empirically validated against the operational criterion. The focus is on cognitive (or throughput) performances in humans as opposed to sensory (input) or motor (output) measures, but the methods should be applicable for development of batteries which will tap input/output functions. A menu of performance tasks is under development for implementation on a battery-operated portable microcomputer, with 21 tests currently available. The tasks are reliable and become stable in minimum amounts of time; appear sensitive to some agents; comprise constructs related to actual job tasks; and are easily administered in most environments. Implications for human factors engineering studies in environmental stress are discussed.
Complementary and Alternative Therapies for Autism Spectrum Disorder
Fusar-Poli, Laura; Rocchetti, Matteo; Provenzani, Umberto; Barale, Francesco
2015-01-01
Background. Complementary and alternative medicine (CAM) represents a popular therapeutic option for patients with autism spectrum disorder (ASD). Unfortunately, there is a paucity of data regarding the efficacy of CAM in ASD. The aim of the present systematic review is to investigate trials of CAM in ASD. Material and Methods. We searched the following databases: MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, CINAHL, Psychology and Behavioral Sciences Collection, Agricola, and Food Science Source. Results. Our literature search identified 2687 clinical publications. After the title/abstract screening, 139 publications were obtained for detailed evaluation. After detailed evaluation 67 studies were included, from hand search of references we retrieved 13 additional studies for a total of 80. Conclusion. There is no conclusive evidence supporting the efficacy of CAM therapies in ASD. Promising results are reported for music therapy, sensory integration therapy, acupuncture, and massage. PMID:26064157
Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio
2018-04-01
Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.
Campacci, Natalia; de Lima, Juliana O; Carvalho, André L; Michelli, Rodrigo D; Haikel, Rafael; Mauad, Edmundo; Viana, Danilo V; Melendez, Matias E; Vazquez, Fabiana de L; Zanardo, Cleyton; Reis, Rui M; Rossi, Benedito M; Palmero, Edenir I
2017-12-01
One of the challenges for Latin American countries is to include in their healthcare systems technologies that can be applied to hereditary cancer detection and management. The aim of the study is to create and validate a questionnaire to identify individuals with possible risk for hereditary cancer predisposition syndromes (HCPS), using different strategies in a Cancer Prevention Service in Brazil. The primary screening questionnaire (PSQ) was developed to identify families at-risk for HCPS. The PSQ was validated using discrimination measures, and the reproducibility was estimated through kappa coefficient. Patients with at least one affirmative answer had the pedigree drawn using three alternative interview approaches: in-person, by telephone, or letter. Validation of these approaches was done. Kappa and intraclass correlation coefficients were used to analyze data's reproducibility considering the presence of clinical criteria for HCPS. The PSQ was applied to a convenience sample of 20,000 women of which 3121 (15.6%) answered at least one affirmative question and 1938 had their pedigrees drawn. The PSQ showed sensitivity and specificity scores of 94.4% and 75%, respectively, and a kappa of 0.64. The strategies for pedigree drawing had reproducibility coefficients of 0.976 and 0.850 for the telephone and letter approaches, respectively. Pedigree analysis allowed us to identify 465 individuals (24.0%) fulfilling at least one clinical criterion for HCPS. The PSQ fulfills its function, allowing the identification of HCPS at-risk families. The use of alternative screening methods may reduce the number of excluded at-risk individuals/families who live in locations where oncogenetic services are not established. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
An Assessment of Commuter Aircraft Noise Impact
NASA Technical Reports Server (NTRS)
Fidell, Sanford; Pearsons, Karl S.; Silvati, Laura; Sneddon, Matthew
1996-01-01
This report examines several approaches to understanding 'the commuter aircraft noise problem.' The commuter aircraft noise problem in the sense addressed in this report is the belief that some aspect(s) of community response to noise produced by commuter aircraft operations may not be fully assessed by conventional environmental noise metrics and methods. The report offers alternate perspectives and approaches for understanding this issue. The report also develops a set of diagnostic screening questions; describes commuter aircraft noise situations at several airports; and makes recommendations for increasing understanding of the practical consequences of greater heterogeneity in the air transport fleet serving larger airports.
Nshimyumukiza, Léon; Durand, Audrey; Gagnon, Mathieu; Douville, Xavier; Morin, Suzanne; Lindsay, Carmen; Duplantie, Julie; Gagné, Christian; Jean, Sonia; Giguère, Yves; Dodin, Sylvie; Rousseau, François; Reinharz, Daniel
2013-02-01
A patient-level Markov decision model was used to simulate a virtual cohort of 500,000 women 40 years old and over, in relation to osteoporosis-related hip, clinical vertebral, and wrist bone fractures events. Sixteen different screening options of three main scenario groups were compared: (1) the status quo (no specific national prevention program); (2) a universal primary prevention program; and (3) a universal screening and treatment program based on the 10-year absolute risk of fracture. The outcomes measured were total directs costs from the perspective of the public health care system, number of fractures, and quality-adjusted life-years (QALYs). Results show that an option consisting of a program promoting physical activity and treatment if a fracture occurs is the most cost-effective (CE) (cost/fracture averted) alternative and also the only cost saving one, especially for women 40 to 64 years old. In women who are 65 years and over, bone mineral density (BMD)-based screening and treatment based on the 10-year absolute fracture risk calculated using a Canadian Association of Radiologists and Osteoporosis Canada (CAROC) tool is the best next alternative. In terms of cost-utility (CU), results were similar. For women less than 65 years old, a program promoting physical activity emerged as cost-saving but BMD-based screening with pharmacological treatment also emerged as an interesting alternative. In conclusion, a program promoting physical activity is the most CE and CU option for women 40 to 64 years old. BMD screening and pharmacological treatment might be considered a reasonable alternative for women 65 years old and over because at a healthcare capacity of $50,000 Canadian dollars ($CAD) for each additional fracture averted or for one QALY gained its probabilities of cost-effectiveness compared to the program promoting physical activity are 63% and 75%, respectively, which could be considered socially acceptable. Consideration of the indirect costs could change these findings. Copyright © 2013 American Society for Bone and Mineral Research.
DNA-Compatible Nitro Reduction and Synthesis of Benzimidazoles.
Du, Huang-Chi; Huang, Hongbing
2017-10-18
DNA-encoded chemical libraries have emerged as a cost-effective alternative to high-throughput screening (HTS) for hit identification in drug discovery. A key factor for productive DNA-encoded libraries is the chemical diversity of the small molecule moiety attached to an encoding DNA oligomer. The library structure diversity is often limited to DNA-compatible chemical reactions in aqueous media. Herein, we describe a facile process for reducing aryl nitro groups to aryl amines. The new protocol offers simple operation and circumvents the pyrophoric potential of the conventional method (Raney nickel). The reaction is performed in aqueous solution and does not compromise DNA structural integrity. The utility of this method is demonstrated by the versatile synthesis of benzimidazoles on DNA.
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2013 CFR
2013-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2010 CFR
2010-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2011 CFR
2011-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2012 CFR
2012-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
USDA-ARS?s Scientific Manuscript database
The identification of specific genes underlying phenotypic variation of complex traits remains one of the greatest challenges in biology despite having genome sequences and more powerful tools. Most genome-wide screens lack sufficient resolving power as they typically depend on linkage. One altern...
P2P is a computer-based tool that supports the comparison of process and product alternatives in terms of environmental impacts. This tool provides screening-level information for use in process design and in product LCA. Twenty one impact categories and data for approximately ...
Forkmann, Thomas; Vehren, Thomas; Boecker, Maren; Norra, Christine; Wirtz, Markus; Gauggel, Siegfried
2009-10-01
The Beck Depression Inventory (BDI) is widely used for depression screening in various patient populations. However, there are still insufficient data about its sensitivity and specificity in nonpsychiatric patients. Furthermore, some research suggests that somatic BDI items heighten its sum score artificially in physically ill patients. The aim of the present study was to validate the conventional BDI cut-off score by examination of its sensitivity and specificity in a mixed sample of cardiac inpatients and compare it to a modified "cognitive-emotional" BDI (BDI(c/e)) after exclusion of somatic items. A total of 126 cardiologic inpatients were assessed. Receiver operating characteristic curves (ROC) were calculated for total BDI (BDI(t)) and BDI(c/e). Screening performance of cut-off scores was evaluated using the Youden Index (Y). With the application of the conventional BDI cut-off score, ROC analysis revealed a moderate overall screening performance with Y=52.6 and an area under the curve (AUC) of 0.83. In contrast, Y improved to 57.5 at a cut-off score of >9, but screening performance was still not optimal. BDI(c/e) showed also a moderate screening performance (AUC=.82); Y was maximized at a cut-off score of >8 (Y=0.53.5). Again, no cut-off score provided optimal screening performance. The BDI cannot be recommended as a formal screening instrument in cardiac inpatients since no cut-off score for either BDI(t) or BDI(c/e) combined both sufficiently high sensitivity and specificity. However, the shorter BDI(c/e) could be used as alternative to BDI(t) which may be confounded in physically ill patients. Generally, researchers should consider using alternative screening instruments (e.g., the Hospital Anxiety and Depression Scale) instead.
ERIC Educational Resources Information Center
Duhon-Haynes, Gwendolyn; And Others
This paper examines alternative certification programs in terms of entrance requirements, supervision and mentoring, and post-certification professional support. A good alternative program uses rigorous screening processes to ensure the selection of qualified teacher interns; provides high-quality preservice training in methodology, classroom…
The focus of this meeting is the SAP's review and comment on the Agency's proposed high-throughput computational model of androgen receptor pathway activity as an alternative to the current Tier 1 androgen receptor assay (OCSPP 890.1150: Androgen Receptor Binding Rat Prostate Cyt...
Lorini, Chiara; Collini, Francesca; Castagnoli, Mariangela; Di Bari, Mauro; Cavallini, Maria Chiara; Zaffarana, Nicoletta; Pepe, Pasquale; Lucenteforte, Ersilia; Vannacci, Alfredo; Bonaccorsi, Guglielmo
2014-10-01
The aim of this study was to use the Malnutrition Universal Screening Tool (MUST) to assess the applicability of alternative versus direct anthropometric measurements for evaluating the risk for malnutrition in older individuals living in nursing homes (NHs). We conducted a cross-sectional survey in 67 NHs in Tuscany, Italy. We measured the weight, standing height (SH), knee height (KH), ulna length (UL), and middle-upper-arm circumference of 641 NH residents. Correlations between the different methods for calculating body mass index (BMI; using direct or alternative measurements) were evaluated by the intraclass correlation coefficient and the Bland-Altman method; agreement in the allocation of participants to the same risk category was assessed by squared weighted kappa statistic and indicators of internal relative validity. The intraclass correlation coefficient for BMI calculated using KH was 0.839 (0.815-0.861), whereas those calculated by UL were 0.890 (0.872-0.905). The limits of agreement were ±6.13 kg/m(2) using KH and ±4.66 kg/m(2) using UL. For BMI calculated using SH, 79.9% of the patients were at low risk, 8.1% at medium risk, and 12.2% at high risk for malnutrition. The agreement between this classification and that obtained using BMI calculated by alternative measurements was "fair-good." When it is not possible to determine risk category by using SH, we suggest using the alternative measurements (primarily UL, due to its highest sensitivity) to predict the height and to compare these evaluations with those obtained by using middle-upper-arm-circumference to predict the BMI. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Nilyanimit, Pornjarim; Chansaenroj, Jira; Poomipak, Witthaya; Praianantathavorn, Kesmanee; Payungporn, Sunchai; Poovorawan, Yong
2018-03-01
Human papillomavirus (HPV) infection causes cervical cancer, thus necessitating early detection by screening. Rapid and accurate HPV genotyping is crucial both for the assessment of patients with HPV infection and for surveillance studies. Fifty-eight cervicovaginal samples were tested for HPV genotypes using four methods in parallel: nested-PCR followed by conventional sequencing, INNO-LiPA, electrochemical DNA chip, and next-generation sequencing (NGS). Seven HPV genotypes (16, 18, 31, 33, 45, 56, and 58) were identified by all four methods. Nineteen HPV genotypes were detected by NGS, but not by nested-PCR, INNO-LiPA, or electrochemical DNA chip. Although NGS is relatively expensive and complex, it may serve as a sensitive HPV genotyping method. Because of its highly sensitive detection of multiple HPV genotypes, NGS may serve as an alternative for diagnostic HPV genotyping in certain situations. © The Korean Society for Laboratory Medicine
Wasko, Michael J; Pellegrene, Kendy A; Madura, Jeffry D; Surratt, Christopher K
2015-01-01
Hundreds of millions of U.S. dollars are invested in the research and development of a single drug. Lead compound development is an area ripe for new design strategies. Therapeutic lead candidates have been traditionally found using high-throughput in vitro pharmacological screening, a costly method for assaying thousands of compounds. This approach has recently been augmented by virtual screening (VS), which employs computer models of the target protein to narrow the search for possible leads. A variant of VS is fragment-based drug design (FBDD), an emerging in silico lead discovery method that introduces low-molecular weight fragments, rather than intact compounds, into the binding pocket of the receptor model. These fragments serve as starting points for "growing" the lead candidate. Current efforts in virtual FBDD within central nervous system (CNS) targets are reviewed, as is a recent rule-based optimization strategy in which new molecules are generated within a 3D receptor-binding pocket using the fragment as a scaffold. This process not only places special emphasis on creating synthesizable molecules but also exposes computational questions worth addressing. Fragment-based methods provide a viable, relatively low-cost alternative for therapeutic lead discovery and optimization that can be applied to CNS targets to augment current design strategies.
Wasko, Michael J.; Pellegrene, Kendy A.; Madura, Jeffry D.; Surratt, Christopher K.
2015-01-01
Hundreds of millions of U.S. dollars are invested in the research and development of a single drug. Lead compound development is an area ripe for new design strategies. Therapeutic lead candidates have been traditionally found using high-throughput in vitro pharmacological screening, a costly method for assaying thousands of compounds. This approach has recently been augmented by virtual screening (VS), which employs computer models of the target protein to narrow the search for possible leads. A variant of VS is fragment-based drug design (FBDD), an emerging in silico lead discovery method that introduces low-molecular weight fragments, rather than intact compounds, into the binding pocket of the receptor model. These fragments serve as starting points for “growing” the lead candidate. Current efforts in virtual FBDD within central nervous system (CNS) targets are reviewed, as is a recent rule-based optimization strategy in which new molecules are generated within a 3D receptor-binding pocket using the fragment as a scaffold. This process not only places special emphasis on creating synthesizable molecules but also exposes computational questions worth addressing. Fragment-based methods provide a viable, relatively low-cost alternative for therapeutic lead discovery and optimization that can be applied to CNS targets to augment current design strategies. PMID:26441817
Manufacturing of prestressed piezoelectric unimorphs using a postfired biasing layer.
Juuti, Jari A; Jantunen, Heli; Moilanen, Veli-Pekka; Leppävuori, Seppo
2006-05-01
A novel manufacturing method for prestressed piezoelectric unimorphs is introduced and the actuator properties are examined. Prestressed PZT 5A and PZT 5H unimorphs with piezo material thickness of 250 microm and 375 microm were manufactured by using sintering and thermal shrinkage of the prestressing material. The process was carried out by screen printing a layer of AgPd paste on one side of the sintered bulk ceramic. As an alternative method, dielectric low temperature co-fired ceramic (LTCC) tape was used as the prestressing material. Different configurations were tested to obtain high displacements and to make a comparison between materials. After firing, the samples were poled, and the displacement versus load characteristics of the resulting actuators were investigated. A maximum displacement of 118 microm was obtained from a 250 microm thick, prestressed PZT 5H actuator with a diameter of 25 mm, in which LTCC tape was used as the prestressing layer. Similarly, the PZT 5H material provided a maximum displacement of 63 microm with a screen-printed AgPd prestressing layer. The manufacturing method described offers a novel approach for the production of a wide range of integrated active structures on, for instance, an LTCC circuit board. This is especially important because piezoelectric bulk materials with high piezoelectric coefficients can be used to produce high displacements.
Honrado, Carlos; Dong, Tao
2014-01-01
Incidence of urinary tract infections (UTIs) is the second highest among all infections; thus, there is a high demand for bacteriuria detection. Escherichia coli are the main cause of UTIs, with microscopy methods and urine culture being the detection standard of these bacteria. However, the urine sampling and analysis required for these methods can be both time-consuming and complex. This work proposes a capacitive touch screen sensor (CTSS) concept as feasible alternative for a portable UTI detection device. Finite element method (FEM) simulations were conducted with a CTSS model. An exponential response of the model to increasing amounts of E. coli and liquid samples was observed. A measurable capacitance change due to E. coli presence and a tangible difference in the response given to urine and water samples were also detected. Preliminary experimental studies were also conducted on a commercial CTSS using liquid solutions with increasing amounts of dissolved ions. The CTSS was capable of distinguishing different volumes of liquids, also giving an exponential response. Furthermore, the CTSS gave higher responses to solutions with a superior amount of ions. Urine samples gave the top response among tested liquids. Thus, the CTSS showed the capability to differentiate solutions by their ionic content. PMID:25196109
Cho, Sun-A; Jeong, Yun Hyeok; Kim, Ji Hoon; Kim, Seoyoung; Cho, Jun-Cheol; Heo, Yong; Heo, Young; Suh, Kyung-Do; Shin, Kyeho; An, Susun
2014-02-10
Cosmetics are normally composed of various ingredients. Some cosmetic ingredients can act as chemical haptens reacting toward proteins or peptides of human skin and they can provoke an immunologic reaction, called as skin sensitization. This haptenation process is very important step of inducing skin sensitization and evaluating the sensitizing potentials of cosmetic ingredients is very important for consumer safety. Therefore, animal alternative methods focusing on monitoring haptenation potential are undergoing vigorous research. To examine the further usefulness of spectrophotometric methods to monitor reactivity of chemicals toward peptides for cosmetic ingredients. Forty chemicals (25 sensitizers and 15 non-sensitizers) were reacted with 2 synthetic peptides, e.g., the cysteine peptides (Ac-RFAACAA-COOH) with free thiol group and the lysine peptides (Ac-RFAAKAA-COOH) with free amine group. Unreacted peptides can be detected after incubating with 5,5'-dithiobis-2-nitrobenzoic acid or fluorescamine™ as detection reagents for free thiol and amine group, respectively. Chemicals were categorized as sensitizers when they induced more than 10% depletion of cysteine peptides or more than 30% depletion of lysine peptides. The sensitivity, specificity, and accuracy were 80.0%, 86.7% and 82.5%, respectively. These results demonstrate that spectrophotometric methods can be an easy, fast, and high-throughput screening tools predicting the skin sensitization potential of chemical including cosmetic ingredient. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Mortality Risk Reductions from Substituting Screen-Time by Discretionary Activities
Wijndaele, Katrien; Sharp, Stephen J; Wareham, Nicholas J; Brage, Søren
2017-01-01
Purpose Leisure-screen-time, including TV viewing, is associated with increased mortality risk. We estimated the all-cause mortality risk reductions associated with substituting leisure-screen-time with different discretionary physical activity types, and the change in mortality incidence associated with different substitution scenarios. Methods 423,659 UK Biobank participants, without stroke, myocardial infarction or cancer history, were followed for 7.6 (1.4) (median (IQR)) years. They reported leisure-screen-time (TV watching and home computer use) and leisure/home activities, categorised as daily-life activities (walking for pleasure; light DIY; heavy DIY) and structured exercise (strenuous sports; other exercises). Iso-temporal substitution modelling in Cox regression provided hazard ratios (95% confidence intervals) for all-cause mortality when substituting screen-time (30 minutes/day) with different discretionary activity types of the same duration. Potential impact fractions (PIFs) estimated the proportional change in mortality incidence associated with different substitution scenarios. Results During 3,202,105 person-years of follow-up, 8,928 participants died. Each 30 minute/day difference in screen-time was associated with lower mortality hazard when modelling substitution of screen-time by an equal amount of daily-life activities (0.95 (0.94-0.97)), as well as structured exercise (0.87 (0.84-0.90)). Re-allocations from screen-time into specific activity subtypes suggested different reductions in mortality hazard (walking for pleasure (0.95 (0.92-0.98)), light DIY (0.97 (0.94-1.00)), heavy DIY (0.93 (0.90-0.96)), strenuous sports (0.87 (0.79-0.95)), other exercises (0.88 (0.84-0.91))). The lowest hazard estimates were found when modelling replacement of TV viewing. PIFs ranged from 4.3% (30 minute/day substitution of screen-time into light DIY) to 14.9% (TV viewing into strenuous sports). Conclusion Substantial public health benefits could be gained by replacing small amounts of screen-time with daily-life activities and structured exercise. Daily-life activities may provide feasible screen-time alternatives, if structured exercise is initially too ambitious. PMID:28106621
Fragment-based drug discovery using rational design.
Jhoti, H
2007-01-01
Fragment-based drug discovery (FBDD) is established as an alternative approach to high-throughput screening for generating novel small molecule drug candidates. In FBDD, relatively small libraries of low molecular weight compounds (or fragments) are screened using sensitive biophysical techniques to detect their binding to the target protein. A lower absolute affinity of binding is expected from fragments, compared to much higher molecular weight hits detected by high-throughput screening, due to their reduced size and complexity. Through the use of iterative cycles of medicinal chemistry, ideally guided by three-dimensional structural data, it is often then relatively straightforward to optimize these weak binding fragment hits into potent and selective lead compounds. As with most other lead discovery methods there are two key components of FBDD; the detection technology and the compound library. In this review I outline the two main approaches used for detecting the binding of low affinity fragments and also some of the key principles that are used to generate a fragment library. In addition, I describe an example of how FBDD has led to the generation of a drug candidate that is now being tested in clinical trials for the treatment of cancer.
Malafaia, Carolina Barbosa; Jardelino, Ana Cláudia Silva; Silva, Alexandre Gomes; de Souza, Elineide Barbosa; Macedo, Alexandre José; Correia, Maria Tereza Dos Santos; Silva, Márcia Vanusa
2018-04-01
This study describes the first antibiofilm and antibacterial screening for plants from Caatinga against Ralstonia solanacearum, a causal agent of bacterial wilt that presents serious difficulties in control. There were prepared 22 aqueous extracts of plants collected in the Vale do Catimbau-PE, Brazil. The potential antibacterial activity was evaluated by absorbance in OD 600 and the antibiofilm activity through the crystal violet method, both of them performed in microplate against isolates of R. solanacearum biofilm formers. The results of the screening showed that Jacaranda rugosa presented antimicrobial activity higher than 90%, while Harpochilus neesianus and Myroxylon peruiferum presented antibiofilm activity higher than 50% for all tested isolates. However, Croton heliotropiifolius showed both the activities, being thus very promising for application in the control of this phytopathogen. The search for viable alternatives to the development of new bioactive compounds safe for the environment, humans, and animals from an adverse and scarce environment such as the Caatinga and encouraged us to find plants that produce effective metabolites against phytopathogenic microorganisms. This in vitro screening is important to guide the development of new products in addition to guide research studies of bioactive compounds.
Castagneto, B; Di Pietrantonj, C; Stevani, I; Anfossi, A; Arzese, M; Giorcelli, L; Giaretto, L
2013-12-01
The importance of prognostic value of the comprehensive geriatric assessment (CGA) is well known in geriatric oncology, but there is no consensus on the use of alternative abbreviated screening methods for the evaluation of older patient disabilities. The participants in this study underwent vulnerable elderly survey 13 (VES 13) at first entry in Oncology Department and were later assessed by a geriatrician according to CGA. A score >3 for VES 13 identified patients as vulnerable. Aim of this study was to evaluate the specificity, sensibility, positive predictive value (PPV), and negative predictive value (NPV) of VES 13 versus cumulative illness rating scale (CIRS), activities of daily living (ADL), instrumental activities of daily living (IADL), and short portable mental status questionnaire (SPMSQ). Hundred and seventeen patients (mean age 78.8 years) entered the study. The NPV of VES was 74.6% for CIRS, 90.1% for IADL, 93.0% for ADL, and 100% for SPMSQ. As for PPV, the VES 13 showed no accuracy. We can conclude that VES 13 demonstrated sufficient accuracy as a screening test in identifying elderly "fit" patients in order to spare the more time-consuming CGA.
Bergsdorf, Christian; Fiez-Vandal, Cédric; Sykes, David A; Bernet, Pascal; Aussenac, Sonia; Charlton, Steven J; Schopfer, Ulrich; Ottl, Johannes; Duckely, Myriam
2016-03-01
Integral membrane proteins (IMPs) play an important role in many cellular events and are involved in numerous pathological processes. Therefore, understanding the structure and function of IMPs is a crucial prerequisite to enable successful targeting of these proteins with low molecular weight (LMW) ligands early on in the discovery process. To optimize IMP purification/crystallization and to identify/characterize LMW ligand-target interactions, robust, reliable, high-throughput, and sensitive biophysical methods are needed. Here, we describe a differential scanning fluorimetry (DSF) screening method using the thiol-reactive BODIPY FL-cystine dye to monitor thermal unfolding of the G-protein-coupled receptor (GPCR), CXCR2. To validate this method, the seven-transmembrane protein CXCR2 was analyzed with a set of well-characterized antagonists. This study showed that the new DSF assay assessed reliably the stability of CXCR2 in a 384-well format. The analysis of 14 ligands with a potency range over 4 log units demonstrated the detection/characterization of LMW ligands binding to the membrane protein target. Furthermore, DSF results cross-validated with the label-free differential static light scattering (DSLS) thermal denaturation method. These results underline the potential of the BODIPY assay format as a general tool to investigate membrane proteins and their interaction partners. © 2015 Society for Laboratory Automation and Screening.
Melo, Carlos Fernando Odir Rodrigues; Navarro, Luiz Claudio; de Oliveira, Diogo Noin; Guerreiro, Tatiane Melina; Lima, Estela de Oliveira; Delafiori, Jeany; Dabaja, Mohamed Ziad; Ribeiro, Marta da Silva; de Menezes, Maico; Rodrigues, Rafael Gustavo Martins; Morishita, Karen Noda; Esteves, Cibele Zanardi; de Amorim, Aline Lopes Lucas; Aoyagui, Caroline Tiemi; Parise, Pierina Lorencini; Milanez, Guilherme Paier; do Nascimento, Gabriela Mansano; Ribas Freitas, André Ricardo; Angerami, Rodrigo; Costa, Fábio Trindade Maranhão; Arns, Clarice Weis; Resende, Mariangela Ribeiro; Amaral, Eliana; Junior, Renato Passini; Ribeiro-do-Valle, Carolina C.; Milanez, Helaine; Moretti, Maria Luiza; Proenca-Modena, Jose Luiz; Avila, Sandra; Rocha, Anderson; Catharino, Rodrigo Ramos
2018-01-01
Recent Zika outbreaks in South America, accompanied by unexpectedly severe clinical complications have brought much interest in fast and reliable screening methods for ZIKV (Zika virus) identification. Reverse-transcriptase polymerase chain reaction (RT-PCR) is currently the method of choice to detect ZIKV in biological samples. This approach, nonetheless, demands a considerable amount of time and resources such as kits and reagents that, in endemic areas, may result in a substantial financial burden over affected individuals and health services veering away from RT-PCR analysis. This study presents a powerful combination of high-resolution mass spectrometry and a machine-learning prediction model for data analysis to assess the existence of ZIKV infection across a series of patients that bear similar symptomatic conditions, but not necessarily are infected with the disease. By using mass spectrometric data that are inputted with the developed decision-making algorithm, we were able to provide a set of features that work as a “fingerprint” for this specific pathophysiological condition, even after the acute phase of infection. Since both mass spectrometry and machine learning approaches are well-established and have largely utilized tools within their respective fields, this combination of methods emerges as a distinct alternative for clinical applications, providing a diagnostic screening—faster and more accurate—with improved cost-effectiveness when compared to existing technologies. PMID:29696139
de Vries, Rob B M; Leenaars, Marlies; Tra, Joppe; Huijbregtse, Robbertjan; Bongers, Erik; Jansen, John A; Gordijn, Bert; Ritskes-Hoitinga, Merel
2015-07-01
An underexposed ethical issue raised by tissue engineering is the use of laboratory animals in tissue engineering research. Even though this research results in suffering and loss of life in animals, tissue engineering also has great potential for the development of alternatives to animal experiments. With the objective of promoting a joint effort of tissue engineers and alternative experts to fully realise this potential, this study provides the first comprehensive overview of the possibilities of using tissue-engineered constructs as a replacement of laboratory animals. Through searches in two large biomedical databases (PubMed, Embase) and several specialised 3R databases, 244 relevant primary scientific articles, published between 1991 and 2011, were identified. By far most articles reviewed related to the use of tissue-engineered skin/epidermis for toxicological applications such as testing for skin irritation. This review article demonstrates, however, that the potential for the development of alternatives also extends to other tissues such as other epithelia and the liver, as well as to other fields of application such as drug screening and basic physiology. This review discusses which impediments need to be overcome to maximise the contributions that the field of tissue engineering can make, through the development of alternative methods, to the reduction of the use and suffering of laboratory animals. Copyright © 2013 John Wiley & Sons, Ltd.
Display screen and method of manufacture therefor
NASA Technical Reports Server (NTRS)
Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)
2002-01-01
A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.
Hutton, John S
2013-01-01
The issue of electronic media use by young children is increasingly important in pediatrics, a major risk factor for numerous chronic conditions. Despite guidelines in place since 1999, screen time is on the rise, aided by new formats removing practically all barriers of use. Key drivers are technological allure, confusion about developmental readiness, and perception of educational value, fueled by potent marketing. This article describes the development of Baby Unplugged, a series of children's board books celebrating "old-school," screen-free childhood. Written by a pediatrician who also owns a children's bookstore, the books were inspired and informed by advocacy projects in the areas of media use and early literacy as a pediatric resident. They reinforce AAP Electronic Media Guidelines, notably discouraging screen-based media under 2 years old, largely by encouraging healthy, fun alternatives. Examples include Pets, Book, and Yard. Multi-sensorial exploration and parent-child engagement are emphasized in a non-prescriptive way, featuring gender and ethnic diversity and activities that are accessible and inexpensive. The author describes challenges faced by pediatricians providing anticipatory guidance for media use, given limited time and resources and the perception that we are out of touch. This is heightened by oft-deceptive marketing of screen-based products more likely to be perceived as "cool." Reach Out and Read is cited as an example of a successful, "cool" intervention, though limited to select populations. Baby Unplugged takes advocacy to the marketplace, where the screen time battle is being lost.
Guerrero-Romero, Fernando; Rodríguez-Morán, Martha
2010-03-01
To validate a method for screening cases of type 2 diabetes and monitoring at-risk people in a community in northern Mexico. The screening instrument for type 2 diabetes (ITD, for its Spanish acronym) was developed using a multiple logistic regression analysis that made it possible to determine the association between a new diagnosis of diabetes (a dependent variable) and 11 known risk factors. Internal validations were performed (through v-fold cross-validation), together with external validations (through the monitoring of a cohort of healthy individuals). In order to estimate the relative risk (RR) of developing type 2 diabetes, the total ITD score is calculated on the basis of an individual's risk factors and compared against a curve that shows the probability of that individual developing the disease. Of the 525 people in the cohort, 438 (83.4%) were followed for an average of 7 years (4.5 to 10 years), for a total of 2 696 person-years; 62 (14.2%) people developed diabetes during the time they were followed. Individuals scoring 55 points based on their risk factors demonstrated a significantly higher risk of developing diabetes in 7 years (RR = 6.1; IC95%: 1.7 to 11.1); the risk was even higher for those with a score of 75 points (RR = 9.4; IC95%: 2.1 to 11.5). The ITD is easy to use and a valid screening alternative for type 2 diabetes. Its use will allow more individuals to benefit from disease prevention methods and early diagnosis without substantially increasing costs and with minimal use of laboratory resources.
Monfregola, Luca; Vitale, Rosa Maria; Amodeo, Pietro; De Luca, Stefania
2009-10-01
The discovery of pharmaceutical agents is a complex, lengthy and costly process, critically depending on the availability of rapid and efficient screening methods. In particular, when targets are large, multidomain proteins, their complexity may affect unfavorably technical feasibility, costs and unambiguity of binding test interpretation. A possible strategy to overcome these problems relies on molecular design of receptor fragments that are: sensible targets for ligand screenings, conformationally stable also as standalone domains, easily synthesized and immobilized on chip for Biacore experiments. An additional desirable feature for new ligands is the ability of selectively targeting alternative conformational states typical of many proteins. To test the feasibility of such approach on a case with potential applicative interest, we developed a surface plasmon resonance (SPR)-based screening method for drug candidates toward HER2, a Tyr-kinase receptor targeted in anticancer therapies. HER2 was mimicked by HER2-DIVMP, a modified fragment of it immobilized onto the sensor surface specifically modeling HER2 domain IV in its bounded form, designed by structural comparison of HER2 alone and in complex with Herceptin, a monoclonal therapeutic anti-HER2 antibody. This design and its implementation in SPR devices was validated by investigating Herceptin- HER2-DIVMP affinity, measuring its dissociation constant (K(D)=19.2 nM). An efficient synthetic procedure to prepare the HER2-DIVMP peptide was also developed. The HER2-DIVMP conformational stability suggested by experimental and computational results, makes it also a valuable candidate as a mold to design new molecules selectively targeting domain IV of HER2.
Sanchis, Yovana; Coscollà, Clara; Roca, Marta; Yusà, Vicent
2015-06-01
An analytical strategy including both the quantitative target analysis of 8 regulated primary aromatic amines (PAAs), as well as a comprehensive post-run target screening of 77 migrating substances, was developed for nylon utensils, using liquid chromatography-orbitrap-high resolution mass spectrometry (LC-HRMS) operating in full scan mode. The accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), and by alternating two acquisition events, ESI+ with and without fragmentation. The target method was validated after statistical optimization of the main ionization and fragmentation parameters. The quantitative method presented appropriate performance to be used in official monitoring with recoveries ranging from 78% to 112%, precision in terms of Relative Standard Deviation (RSD) was less than 15%, and the limits of quantification were between 2 and 2.5 µg kg(-1). For post-target screening, a customized theoretical database was built for food contact material migrants, including bisphenols, phthalates, and other amines. For identification purposes, accurate exact mass (<5 ppm) and some diagnostic ions including fragments were used. The strategy was applied to 10 real samples collected from different retailers in the Valencian Region (Spain) during 2014. Six out of eight target PAAs were detected in at least one sample in the target analysis. The most frequently detected compounds were 4,4'-methylenedianiline and aniline, with concentrations ranging from 2.4 to 19,715 µg kg(-1) and 2.5 to 283 µg kg(-1), respectively. Two phthalates were identified and confirmed in the post-run target screening analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Using information from historical high-throughput screens to predict active compounds.
Riniker, Sereina; Wang, Yuan; Jenkins, Jeremy L; Landrum, Gregory A
2014-07-28
Modern high-throughput screening (HTS) is a well-established approach for hit finding in drug discovery that is routinely employed in the pharmaceutical industry to screen more than a million compounds within a few weeks. However, as the industry shifts to more disease-relevant but more complex phenotypic screens, the focus has moved to piloting smaller but smarter chemically/biologically diverse subsets followed by an expansion around hit compounds. One standard method for doing this is to train a machine-learning (ML) model with the chemical fingerprints of the tested subset of molecules and then select the next compounds based on the predictions of this model. An alternative approach would be to take advantage of the wealth of bioactivity information contained in older (full-deck) screens using so-called HTS fingerprints, where each element of the fingerprint corresponds to the outcome of a particular assay, as input to machine-learning algorithms. We constructed HTS fingerprints using two collections of data: 93 in-house assays and 95 publicly available assays from PubChem. For each source, an additional set of 51 and 46 assays, respectively, was collected for testing. Three different ML methods, random forest (RF), logistic regression (LR), and naïve Bayes (NB), were investigated for both the HTS fingerprint and a chemical fingerprint, Morgan2. RF was found to be best suited for learning from HTS fingerprints yielding area under the receiver operating characteristic curve (AUC) values >0.8 for 78% of the internal assays and enrichment factors at 5% (EF(5%)) >10 for 55% of the assays. The RF(HTS-fp) generally outperformed the LR trained with Morgan2, which was the best ML method for the chemical fingerprint, for the majority of assays. In addition, HTS fingerprints were found to retrieve more diverse chemotypes. Combining the two models through heterogeneous classifier fusion led to a similar or better performance than the best individual model for all assays. Further validation using a pair of in-house assays and data from a confirmatory screen--including a prospective set of around 2000 compounds selected based on our approach--confirmed the good performance. Thus, the combination of machine-learning with HTS fingerprints and chemical fingerprints utilizes information from both domains and presents a very promising approach for hit expansion, leading to more hits. The source code used with the public data is provided.
Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy; Pardee, Dana J; McLean, Sarah; Marrow, Elliot J; Mimiaga, Matthew J; Panther, Lori; Gelman, Marcy; Green, Jamison; Potter, Jennifer
2017-06-23
Cervical cancer, nearly all cases of which are caused by one of several high-risk strains of the human papillomavirus (hr-HPV), leads to significant morbidity and mortality in individuals with a cervix. Trans masculine (TM) individuals were born with female reproductive organs and identify as male, man, transgender man, or another diverse gender identity different from their female assigned sex at birth. Routine preventive sexual health screening of TM patients is recommended, including screening for cervical cancer and other sexually transmitted infections (STIs); however, as many as one in three TM patients are not up-to-date per recommended U.S. Among cisgender (non-transgender) women, self-swab hr.-HPV DNA testing as a primary cervical cancer screening method and self-swab specimen collection for other STIs have high levels of acceptability. No study has yet been conducted to compare the performance and acceptability of self- and provider-collected swabs for hr.-HPV DNA testing and other STIs in TM patients. This article describes the study protocol for a mixed-methods biobehavioral investigation enrolling 150 sexually active TM to (1) assess the clinical performance and acceptability of a vaginal self-swab for hr.-HPV DNA testing compared to provider cervical swab and cervical cytology, and (2) gather acceptability data on self-collected specimens for other STIs. Study participation entails a one-time clinical visit at Fenway Health in Boston, MA comprised of informed consent, quantitative assessment, venipuncture for syphilis testing and HIV (Rapid OraQuick) testing, randomization, collection of biological specimens/biomarkers, participant and provider satisfaction survey, and qualitative exit interview. Participants are compensated $100. The primary study outcomes are concordance (kappa statistic) and performance (sensitivity and specificity) of self-collected vaginal HPV DNA specimens vs provider-collected cervical HPV swabs as a gold standard. This study addresses critical gaps in current clinical knowledge of sexual health in TM patients, including comparing alternative strategies for screening and diagnosis of cervical cancer, hr.-HPV, and other STIs. Findings have implications for improving the delivery of sexual health screening to this often overlooked and underserved patient population. Less-invasive patient-centered strategies may also generalize to other at-risk cisgender female populations that face barriers to timely and needed STI and cervical cancer screening. ClinicalTrials.gov ID: NCT02401867.
Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong
2016-11-01
For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Hosaka, Shuto; Honda, Takuto; Lee, Seon Hwa; Oe, Tomoyuki
2018-06-01
Candidate drugs that can be metabolically transformed into reactive electrophilic products, such as epoxides, quinones, and nitroso compounds, are of special concern because subsequent covalent binding to bio-macromolecules can cause adverse drug reactions, such as allergic reactions, hepatotoxicity, and genotoxicity. Several strategies have been reported for screening reactive metabolites, such as a covalent binding assay with radioisotope-labeled drugs and a trapping method followed by LC-MS/MS analyses. Of these, a trapping method using glutathione is the most common, especially at the early stage of drug development. However, the cysteine of glutathione is not the only nucleophilic site in vivo; lysine, histidine, arginine, and DNA bases are also nucleophilic. Indeed, the glutathione trapping method tends to overlook several types of reactive metabolites, such as aldehydes, acylglucuronides, and nitroso compounds. Here, we introduce an alternate way for screening reactive metabolites as follows: A mixture of the light and heavy isotopes of simplified amino acid motifs and a DNA motif is used as a biomimetic trapping cocktail. This mixture consists of [ 2 H 0 ]/[ 2 H 3 ]-1-methylguanidine (arginine motif, Δ 3 Da), [ 2 H 0 ]/[ 2 H 4 ]-2-mercaptoethanol (cysteine motif, Δ 4 Da), [ 2 H 0 ]/[ 2 H 5 ]-4-methylimidazole (histidine motif, Δ 5 Da), [ 2 H 0 ]/[ 2 H 9 ]-n-butylamine (lysine motif, Δ 9 Da), and [ 13 C 0 , 15 N 0 ]/[ 13 C 1 , 15 N 2 ]-2'-deoxyguanosine (DNA motif, Δ 3 Da). Mass tag triggered data-dependent acquisition is used to find the characteristic doublet peaks, followed by specific identification of the light isotope peak using MS/MS. Forty-two model drugs were examined using an in vitro microsome experiment to validate the strategy. Graphical abstract Biomimetic trapping cocktail to screen reactive metabolites.
Holme, Øyvind; Schoen, Robert E; Senore, Carlo; Segnan, Nereo; Hoff, Geir; Løberg, Magnus; Bretthauer, Michael; Adami, Hans-Olov; Kalager, Mette
2017-01-01
Objective To compare the effectiveness of flexible sigmoidoscopy in screening for colorectal cancer by patient sex and age. Design Pooled analysis of randomised trials (the US Prostate, Lung, Colorectal and Ovarian cancer screening trial (PLCO), the Italian Screening for Colon and Rectum trial (SCORE), and the Norwegian Colorectal Cancer Prevention trial (NORCCAP)). Data sources Aggregated data were pooled from each randomised trial on incidence of colorectal cancer and mortality stratified by sex, age at screening, and colon subsite (distal v proximal). Eligibility criteria for selecting studies Invited individuals aged 55-74 (PLCO), 55-64 (SCORE), and 50-64 (NORCCAP). Individuals were randomised to receive flexible sigmoidoscopy screening once only (SCORE and NORCCAP) or twice (PLCO), or receive usual care (no intervention). Results 287 928 individuals were included in the pooled analysis; 115 139 randomised to screening and 172 789 to usual care. Compliance rates were 58%, 63%, and 87% in SCORE, NORCCAP, and PLCO, respectively. Median follow-up was 10.5 to 12.1 years. Screening reduced the incidence of colorectal cancer in men (relative risk 0.76; 95% confidence interval 0.70 to 0.83) and women (0.83; 0.75 to 0.92). No difference in the effect of screening was seen between men younger than 60 and those older than 60. Screening reduced the incidence of colorectal cancer in women younger than 60 (relative risk 0.71; 95% confidence interval 0.59 to 0.84), but not significantly in those aged 60 or older (0.90; 0.80 to 1.02). Colorectal cancer mortality was significantly reduced in both younger and older men, and in women younger than 60. Screening reduced colorectal cancer incidence to a similar extent in the distal colon in men and women, but there was no effect of screening in the proximal colon in older women with a significant interaction between sex and age group (P=0.04). Conclusion Flexible sigmoidoscopy is an effective tool for colorectal cancer screening in men and younger women. The benefit is smaller and not statistically significant for women aged over 60; alternative screening methods that more effectively detect proximal tumours should be considered for these women. PMID:28087510
Looking at genes in the workplace.
Holden, C
1982-07-23
The Office of Technology Assessment recently testified at a congressional hearing that many corporations are considering genetic screening of employees. Biochemical genetic screening of "susceptible" workers is aimed at identifying individuals unsuitable for specific jobs, and cytogenic monitoring involves the testing of groups of workers for chromosome aberrations that might occur as a result of exposure to chemicals. The apparent surge of interest in such testing requires that several legal, ethical, and policy issues be addressed, including the potential for discrimination, the misuse of screening as an alternative to cleaning up the workplace, the predictive capability of the tests, and the necessity for the development of guidelines for screening programs.
Zehbe, Ingeborg; Wakewich, Pamela; King, Amy-Dee; Morrisseau, Kyla; Tuck, Candace
2017-01-01
Background While (Pap)anicolaou screening has helped to decrease cervical cancer incidence in Canada, First Nations women continue to have a higher burden and mortality relative to mainstream populations. Many First Nations women may feel uncomfortable with the invasiveness of this test, contributing to this statistic. Implemented from 2009 to 2015 in 10 Northwest Ontario First Nations communities, the Anishinaabek Cervical Cancer Screening Study (ACCSS) uniquely addressed this Indigenous health inequity through a mixed methods approach. Objective Our goal was to offer an alternative test which the women could do themselves: human papillomavirus (HPV) testing based on self-sampling. We investigated whether First Nations women preferred HPV self-sampling over healthcare provider (HCP)-administered Pap screening. Methods Participatory action researchinformed by the ethical space concept has guided all stages of the ACCSS. We conducted qualitative interviews with 16 HCPs and 8 focus group discussions with 69 female community members followed by a cluster-randomised controlled trial (RCT). Here, we draw on the qualitative field data and an end-of-study community update gathering to disseminate and contextualise research findings. Informant data were evaluated using thematic analysis. Results We discuss factors influencing participants’ strong preference for HPV self-sampling over physician-conducted Pap screening. Key arguments included enhanced accessibility and more personal control, less physical and emotional discomfort and fewer concerns regarding privacy of test results. For future implementation of HPV self-sampling, study participants emphasised the need for more culturally sensitive education addressed to community members of all genders, starting at school, clarifying that HPV causes cervical cancer. Further, HPV infection should be de-stigmatised by accentuating that it affects men and women alike. Conclusion Here we show that self-sampling in conjunction with community engagement and culturally sensitive education and could be a viable option for underscreened Canadian First Nations women. These informant data echo our previous RCT results. PMID:28864487
Sass, Jennifer; Heine, Lauren; Hwang, Nina
2016-11-08
Increased concern for potential health and environmental impacts of chemicals, including nanomaterials, in consumer products is driving demand for greater transparency regarding potential risks. Chemical hazard assessment is a powerful tool to inform product design, development and procurement and has been integrated into alternative assessment frameworks. The extent to which assessment methods originally designed for conventionally-sized materials can be used for nanomaterials, which have size-dependent physical and chemical properties, have not been well established. We contracted with a certified GreenScreen profiler to conduct three GreenScreen hazard assessments, for conventional silver and two forms of nanosilver. The contractor summarized publicly available literature, and used defined GreenScreen hazard criteria and expert judgment to assign and report hazard classification levels, along with indications of confidence in those assignments. Where data were not available, a data gap (DG) was assigned. Using the individual endpoint scores, an aggregated benchmark score (BM) was applied. Conventional silver and low-soluble nanosilver were assigned the highest possible hazard score and a silica-silver nanocomposite called AGS-20 could not be scored due to data gaps. AGS-20 is approved for use as antimicrobials by the US Environmental Protection Agency. An existing method for chemical hazard assessment and communication can be used - with minor adaptations- to compare hazards across conventional and nano forms of a substance. The differences in data gaps and in hazard profiles support the argument that each silver form should be considered unique and subjected to hazard assessment to inform regulatory decisions and decisions about product design and development. A critical limitation of hazard assessments for nanomaterials is the lack of nano-specific hazard data - where data are available, we demonstrate that existing hazard assessment systems can work. The work is relevant for risk assessors and regulators. We recommend that regulatory agencies and others require more robust data sets on each novel nanomaterial before granting market approval.
Exner, Jörg; Albrecht, Gaby; Schönauer-Kamin, Daniela; Kita, Jaroslaw; Moos, Ralf
2017-01-01
The pulsed polarization technique on solid electrolytes is based on alternating potential pulses interrupted by self-discharge pauses. Since even small concentrations of nitrogen oxides (NOx) in the ppm range significantly change the polarization and discharge behavior, pulsed polarization sensors are well suited to measure low amounts of NOx. In contrast to all previous investigations, planar pulsed polarization sensors were built using an electrolyte thick film and platinum interdigital electrodes on alumina substrates. Two different sensor layouts were investigated, the first with buried Pt electrodes under the electrolyte and the second one with conventional overlying Pt electrodes. Electrolyte thick films were either formed by aerosol deposition or by screen-printing, therefore exhibiting a dense or porous microstructure, respectively. For screen-printed electrolytes, the influence of the electrolyte resistance on the NOx sensing ability was investigated as well. Sensors with buried electrodes showed little to no response even at higher NOx concentrations, in good agreement with the intended sensor mechanism. Electrolyte films with overlying electrodes, however, allowed the quantitative detection of NOx. In particular, aerosol deposited electrolytes exhibited high sensitivities with a sensor output signal ΔU of 50 mV and 75 mV for 3 ppm of NO and NO2, respectively. For screen-printed electrolytes, a clear trend indicated a decrease in sensitivity with increased electrolyte resistance. PMID:28933736
Masch, Rachel; Ditzian, Lauren R; April, Ayana K; Maza, Mauricio; Peralta, Ethel; Cremer, Miriam L
2011-09-01
Visual inspection with acetic acid (VIA) is a simple, low-cost alternative to traditional Pap smears that could greatly benefit the amount of screening and treatment available in low-resource areas, such as rural El Salvador. The objective of this study was to train Salvadoran health providers in VIA and cryotherapy using a week-long competency course. Health providers participated in the VIA training course, which consisted of 1 half-day of didactics, followed by 4 and 1 half days of clinical training. Pretests and posttests were administered. A 1-day didactic refresher course was administered to assess the quality of services being provided. Sixty-eight nurses and physicians completed the training course. Each trainee screened approximately 120 women and performed, on average, seven cryotherapy treatments. The average trainee improved his or her score by 15% on the theoretical test and 16.7% on the image test. At the completion of the 1-day refresher, average test scores were the highest among all the courses. The final assessment was based on 41 providers. The course proved a successful tool for training healthcare providers in methods of cervical cancer screening and treatment. The course is replicable in other low-resource settings in different countries. It also provided trainees with the opportunity to adapt their clinical skills in their realistic work setting.
Exner, Jörg; Albrecht, Gaby; Schönauer-Kamin, Daniela; Kita, Jaroslaw; Moos, Ralf
2017-07-26
The pulsed polarization technique on solid electrolytes is based on alternating potential pulses interrupted by self-discharge pauses. Since even small concentrations of nitrogen oxides (NO x ) in the ppm range significantly change the polarization and discharge behavior, pulsed polarization sensors are well suited to measure low amounts of NO x . In contrast to all previous investigations, planar pulsed polarization sensors were built using an electrolyte thick film and platinum interdigital electrodes on alumina substrates. Two different sensor layouts were investigated, the first with buried Pt electrodes under the electrolyte and the second one with conventional overlying Pt electrodes. Electrolyte thick films were either formed by aerosol deposition or by screen-printing, therefore exhibiting a dense or porous microstructure, respectively. For screen-printed electrolytes, the influence of the electrolyte resistance on the NO x sensing ability was investigated as well. Sensors with buried electrodes showed little to no response even at higher NO x concentrations, in good agreement with the intended sensor mechanism. Electrolyte films with overlying electrodes, however, allowed the quantitative detection of NO x . In particular, aerosol deposited electrolytes exhibited high sensitivities with a sensor output signal Δ U of 50 mV and 75 mV for 3 ppm of NO and NO₂, respectively. For screen-printed electrolytes, a clear trend indicated a decrease in sensitivity with increased electrolyte resistance.
Alternative Fuels Data Center: Video Download Help
a Windows Media Video (WMV) link and select "Save Target As..." from the shortcut menu. To player on the screen. You can also expand the video to play in full-screen mode using Windows Media played in Windows Media Player. Download Windows Media Player. To watch videos on a Mac, double-click the
L.R. Grosenbaugh
1967-01-01
Describes an expansible computerized system that provides data needed in regression or covariance analysis of as many as 50 variables, 8 of which may be dependent. Alternatively, it can screen variously generated combinations of independent variables to find the regression with the smallest mean-squared-residual, which will be fitted if desired. The user can easily...
Trade-offs in Cervical Cancer Prevention: Balancing Benefits and Risks
Stout, Natasha K.; Goldhaber-Fiebert, Jeremy D.; Ortendahl, Jesse D.; Goldie, Sue J.
2009-01-01
Background New screening and vaccination technologies will provide women with more options for cervical cancer prevention. Because the risk of cervical cancer diminishes with effective routine screening, women may wish to consider additional attributes, such as the likelihood of false-positive results and diagnostic procedures for mild abnormalities likely to resolve without intervention in their screening choices. Methods We used an empirically calibrated simulation model of cervical cancer in the United States to assess the benefits and potential risks associated with prevention strategies differing by primary screening test, triage test for abnormal results (cytologic testing, human papillomavirus [HPV] DNA test), and screening frequency. Outcomes included colposcopy referrals, cervical intraepithelial neoplasia (CIN) types 1 and 2 or 3, lifetime cancer risk, and quality-adjusted life expectancy. Results Across strategies, colposcopy referrals and diagnostic workups varied 3-fold, although diagnostic rates of CIN 2 or 3 were similar and 95% of positive screening test results were for mild abnormalities likely to resolve on their own. For a representative group of a thousand 20-year-old women undergoing triennial screening for 10 years, we expect 1038 colposcopy referrals (7 CIN 2 or 3 diagnoses) from combined cytologic and HPV DNA testing and fewer than 200 referrals (6–7 CIN 2 or 3 diagnoses) for strategies that use triage testing. Similarly, for a thousand 40-year-old women, combined cytologic and HPV DNA testing led to 489 referrals (9 CIN 2 or 3), whereas alternative strategies resulted in fewer than 150 referrals (7–8 CIN 2 or 3). Using cytologic testing followed by triage testing in younger women minimizes both diagnostic workups and positive HPV test results, whereas in older women diagnostic workups are minimized with HPV DNA testing followed by cytologic triage testing. Conclusions Clinically relevant information highlighting trade-offs among cervical cancer prevention strategies allows for inclusion of personal preferences into women’s decision making about screening and provides additional dimensions to the construction of clinical guidelines. PMID:18809815
Prabhu, Vimalanand S.; Farnham, Paul G.; Hutchinson, Angela B.; Soorapanth, Sada; Heffelfinger, James D.; Golden, Matthew R.; Brooks, John T.; Rimland, David; Sansom, Stephanie L.
2011-01-01
Background Identifying and treating persons with human immunodeficiency virus (HIV) infection early in their disease stage is considered an effective means of reducing the impact of the disease. We compared the cost-effectiveness of HIV screening in three settings, sexually transmitted disease (STD) clinics serving men who have sex with men, hospital emergency departments (EDs), settings where patients are likely to be diagnosed early, and inpatient diagnosis based on clinical manifestations. Methods and Findings We developed the Progression and Transmission of HIV/AIDS model, a health state transition model that tracks index patients and their infected partners from HIV infection to death. We used program characteristics for each setting to compare the incremental cost per quality-adjusted life year gained from early versus late diagnosis and treatment. We ran the model for 10,000 index patients for each setting, examining alternative scenarios, excluding and including transmission to partners, and assuming HAART was initiated at a CD4 count of either 350 or 500 cells/µL. Screening in STD clinics and EDs was cost-effective compared with diagnosing inpatients, even when including only the benefits to the index patients. Screening patients in STD clinics, who have less-advanced disease, was cost-effective compared with ED screening when treatment with HAART was initiated at a CD4 count of 500 cells/µL. When the benefits of reduced transmission to partners from early diagnosis were included, screening in settings with less-advanced disease stages was cost-saving compared with screening later in the course of infection. The study was limited by a small number of observations on CD4 count at diagnosis and by including transmission only to first generation partners of the index patients. Conclusions HIV prevention efforts can be advanced by screening in settings where patients present with less-advanced stages of HIV infection and by initiating treatment with HAART earlier in the course of infection. PMID:21625489
Effectiveness of early detection on breast cancer mortality reduction in Catalonia (Spain)
2009-01-01
Background At present, it is complicated to use screening trials to determine the optimal age intervals and periodicities of breast cancer early detection. Mathematical models are an alternative that has been widely used. The aim of this study was to estimate the effect of different breast cancer early detection strategies in Catalonia (Spain), in terms of breast cancer mortality reduction (MR) and years of life gained (YLG), using the stochastic models developed by Lee and Zelen (LZ). Methods We used the LZ model to estimate the cumulative probability of death for a cohort exposed to different screening strategies after T years of follow-up. We also obtained the cumulative probability of death for a cohort with no screening. These probabilities were used to estimate the possible breast cancer MR and YLG by age, period and cohort of birth. The inputs of the model were: incidence of, mortality from and survival after breast cancer, mortality from other causes, distribution of breast cancer stages at diagnosis and sensitivity of mammography. The outputs were relative breast cancer MR and YLG. Results Relative breast cancer MR varied from 20% for biennial exams in the 50 to 69 age interval to 30% for annual exams in the 40 to 74 age interval. When strategies differ in periodicity but not in the age interval of exams, biennial screening achieved almost 80% of the annual screening MR. In contrast to MR, the effect on YLG of extending screening from 69 to 74 years of age was smaller than the effect of extending the screening from 50 to 45 or 40 years. Conclusion In this study we have obtained a measure of the effect of breast cancer screening in terms of mortality and years of life gained. The Lee and Zelen mathematical models have been very useful for assessing the impact of different modalities of early detection on MR and YLG in Catalonia (Spain). PMID:19754959
Guo, Baoshan; Lei, Cheng; Kobayashi, Hirofumi; Ito, Takuro; Yalikun, Yaxiaer; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke
2017-05-01
The development of reliable, sustainable, and economical sources of alternative fuels to petroleum is required to tackle the global energy crisis. One such alternative is microalgal biofuel, which is expected to play a key role in reducing the detrimental effects of global warming as microalgae absorb atmospheric CO 2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid amounts and fail to characterize a diverse population of microalgal cells with single-cell resolution in a non-invasive and interference-free manner. Here high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy was demonstrated. In particular, Euglena gracilis, an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement), within lipid droplets was investigated. The optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch quantitative phase microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase maps of every single cell at a high throughput of 10,000 cells/s, enabling accurate cell classification without the need for fluorescent staining. Specifically, the dataset was used to characterize heterogeneous populations of E. gracilis cells under two different culture conditions (nitrogen-sufficient and nitrogen-deficient) and achieve the cell classification with an error rate of only 2.15%. The method holds promise as an effective analytical tool for microalgae-based biofuel production. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
Oral Fluid Testing for Drugs of Abuse
Bosker, Wendy M.; Huestis, Marilyn A.
2011-01-01
BACKGROUND Oral fluid (OF) is an exciting alternative matrix for monitoring drugs of abuse in workplace, clinical toxicology, criminal justice, and driving under the influence of drugs (DUID) programs. During the last 5 years, scientific and technological advances in OF collection, point-of-collection testing devices, and screening and confirmation methods were achieved. Guidelines were proposed for workplace OF testing by the Substance Abuse and Mental Health Services Administration, DUID testing by the European Union’s Driving under the Influence of Drugs, Alcohol and Medicines (DRUID) program, and standardization of DUID research. Although OF testing is now commonplace in many monitoring programs, the greatest current limitation is the scarcity of controlled drug administration studies available to guide interpretation. CONTENT This review outlines OF testing advantages and limitations, and the progress in OF that has occurred during the last 5 years in collection, screening, confirmation, and interpretation of cannabinoids, opioids, amphetamines, cocaine, and benzodiazepines. We examine controlled drug administration studies, immunoassay and chromatographic methods, collection devices, point-of-collection testing device performance, and recent applications of OF testing. SUMMARY Substance Abuse and Mental Health Services Administration approval of OF testing was delayed because questions about drug OF disposition were not yet resolved, and collection device performance and testing assays required improvement. Here, we document the many advances achieved in the use of OF. Additional research is needed to identify new bio-markers, determine drug detection windows, characterize OF adulteration techniques, and evaluate analyte stability. Nevertheless, there is no doubt that OF offers multiple advantages as an alternative matrix for drug monitoring and has an important role in DUID, treatment, workplace, and criminal justice programs. PMID:19745062
Klassen, Tara L.; von Rüden, Eva-Lotta; Drabek, Janice; Noebels, Jeffrey L.; Goldman, Alica M.
2013-01-01
Genetic testing and research have increased the demand for high-quality DNA that has traditionally been obtained by venipuncture. However, venous blood collection may prove difficult in special populations and when large-scale specimen collection or exchange is prerequisite for international collaborative investigations. Guthrie/FTA card–based blood spots, buccal scrapes, and finger nail clippings are DNA-containing specimens that are uniquely accessible and thus attractive as alternative tissue sources (ATS). The literature details a variety of protocols for extraction of nucleic acids from a singular ATS type, but their utility has not been systematically analyzed in comparison with conventional sources such as venous blood. Additionally, the efficacy of each protocol is often equated with the overall nucleic acid yield but not with the analytical performance of the DNA during mutation detection. Together with a critical in-depth literature review of published extraction methods, we developed and evaluated an all-inclusive approach for serial, systematic, and direct comparison of DNA utility from multiple biological samples. Our results point to the often underappreciated value of these alternative tissue sources and highlight ways to maximize the ATS-derived DNA for optimal quantity, quality, and utility as a function of extraction method. Our comparative analysis clarifies the value of ATS in genomic analysis projects for population-based screening, diagnostics, molecular autopsy, medico-legal investigations, or multi-organ surveys of suspected mosaicisms. PMID:22796560
Huertas, César S.; Domínguez-Zotes, Santos; Lechuga, Laura M.
2017-01-01
Personalized medicine is a promising tool not only for prevention, screening and development of more efficient treatment strategies, but also for diminishing the side effects caused by current therapies. Deciphering gene regulation pathways provides a reliable prognostic analysis to elucidate the origin of grave diseases and facilitate the selection of the most adequate treatment for each individual. Alternative splicing of mRNA precursors is one of these gene regulation pathways and enables cells to generate different protein outputs from the same gene depending on their developmental or homeostatic status. Its deregulation is strongly linked to disease onset and progression constituting a relevant and innovative class of biomarker. Herein we report a highly selective and sensitive nanophotonic biosensor based on the direct monitoring of the aberrant alternative splicing of Fas gene. Unlike conventional methods, the nanobiosensor performs a real-time detection of the specific isoforms in the fM-pM range without any cDNA synthesis or PCR amplification requirements. The nanobiosensor has been proven isoform-specific with no crosshybridization, greatly minimizing detection biases. The demonstrated high sensitivity and specificity make our nanobiosensor ideal for examining significant tumor-associated expression shifts of alternatively spliced isoforms for the early and accurate theranostics of cancer. PMID:28120920
Huertas, César S; Domínguez-Zotes, Santos; Lechuga, Laura M
2017-01-25
Personalized medicine is a promising tool not only for prevention, screening and development of more efficient treatment strategies, but also for diminishing the side effects caused by current therapies. Deciphering gene regulation pathways provides a reliable prognostic analysis to elucidate the origin of grave diseases and facilitate the selection of the most adequate treatment for each individual. Alternative splicing of mRNA precursors is one of these gene regulation pathways and enables cells to generate different protein outputs from the same gene depending on their developmental or homeostatic status. Its deregulation is strongly linked to disease onset and progression constituting a relevant and innovative class of biomarker. Herein we report a highly selective and sensitive nanophotonic biosensor based on the direct monitoring of the aberrant alternative splicing of Fas gene. Unlike conventional methods, the nanobiosensor performs a real-time detection of the specific isoforms in the fM-pM range without any cDNA synthesis or PCR amplification requirements. The nanobiosensor has been proven isoform-specific with no crosshybridization, greatly minimizing detection biases. The demonstrated high sensitivity and specificity make our nanobiosensor ideal for examining significant tumor-associated expression shifts of alternatively spliced isoforms for the early and accurate theranostics of cancer.
Role of re-screening of cervical smears in internal quality control.
Baker, A; Melcher, D; Smith, R
1995-01-01
AIMS--To investigate the use of rapid re-screening as a quality control method for previously screened cervical slides; to compare this method with 10% random re-screening and clinically indicated double screening. METHODS--Between June 1990 and December 1994, 117,890 negative smears were subjected to rapid re-screening. RESULTS--This study shows that rapid re-screening detects far greater numbers of false negative cases when compared with both 10% random re-screening and clinically indicated double screening, with no additional demand on human resources. The technique also identifies variation in the performance of screening personnel as an additional benefit. CONCLUSION--Rapid re-screening is an effective method of quality control. Although less sensitive, rapid re-screening should replace 10% random re-screening and selected re-screening as greater numbers of false negative results are detected while consuming less resources. PMID:8543619
Use of unbalanced laminates as a screening method for microcracking
NASA Technical Reports Server (NTRS)
Papadopoulos, Demetrios S.; Bowles, Kenneth J.
1990-01-01
State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.
Mesoscopic Field-Effect-Induced Devices in Depleted Two-Dimensional Electron Systems
NASA Astrophysics Data System (ADS)
Bachsoliani, N.; Platonov, S.; Wieck, A. D.; Ludwig, S.
2017-12-01
Nanoelectronic devices embedded in the two-dimensional electron system (2DES) of a GaAs /(Al ,Ga )As heterostructure enable a large variety of applications ranging from fundamental research to high-speed transistors. Electrical circuits are thereby commonly defined by creating barriers for carriers by the selective depletion of a preexisting 2DES. We explore an alternative approach: we deplete the 2DES globally by applying a negative voltage to a global top gate and screen the electric field of the top gate only locally using nanoscale gates placed on the wafer surface between the plane of the 2DES and the top gate. Free carriers are located beneath the screen gates, and their properties can be controlled by means of geometry and applied voltages. This method promises considerable advantages for the definition of complex circuits by the electric-field effect, as it allows us to reduce the number of gates and simplify gate geometries. Examples are carrier systems with ring topology or large arrays of quantum dots. We present a first exploration of this method pursuing field effect, Hall effect, and Aharonov-Bohm measurements to study electrostatic, dynamic, and coherent properties.
2010-01-01
Background Sedentary behavior is considered a separate construct from physical activity and engaging in sedentary behaviors results in health effects independent of physical activity levels. A major source of sedentary behavior in children is time spent viewing TV or movies, playing video games, and using computers. To date no study has examined the impact of neighborhood socioeconomic status (SES) on pre-school children's screen time behavior. Methods Proxy reports of weekday and weekend screen time (TV/movies, video games, and computer use) were completed by 1633 parents on their 4-5 year-old children in Edmonton, Alberta between November, 2005 and August, 2007. Postal codes were used to classified neighborhoods into low, medium or high SES. Multiple linear and logistic regression models were conducted to examine relationships between screen time and neighborhood SES. Results Girls living in low SES neighborhoods engaged in significantly more weekly overall screen time and TV/movie minutes compared to girls living in high SES neighborhoods. The same relationship was not observed in boys. Children living in low SES neighborhoods were significantly more likely to be video game users and less likely to be computer users compared to children living in high SES neighborhoods. Also, children living in medium SES neighborhoods were significantly less likely to be computer users compared to children living in high SES neighborhoods. Conclusions Some consideration should be given to providing alternative activity opportunities for children, especially girls who live in lower SES neighborhoods. Also, future research should continue to investigate the independent effects of neighborhood SES on screen time as well as the potential mediating variables for this relationship. PMID:20573262
"Dip-and-read" paper-based analytical devices using distance-based detection with color screening.
Yamada, Kentaro; Citterio, Daniel; Henry, Charles S
2018-05-15
An improved paper-based analytical device (PAD) using color screening to enhance device performance is described. Current detection methods for PADs relying on the distance-based signalling motif can be slow due to the assay time being limited by capillary flow rates that wick fluid through the detection zone. For traditional distance-based detection motifs, analysis can take up to 45 min for a channel length of 5 cm. By using a color screening method, quantification with a distance-based PAD can be achieved in minutes through a "dip-and-read" approach. A colorimetric indicator line deposited onto a paper substrate using inkjet-printing undergoes a concentration-dependent colorimetric response for a given analyte. This color intensity-based response has been converted to a distance-based signal by overlaying a color filter with a continuous color intensity gradient matching the color of the developed indicator line. As a proof-of-concept, Ni quantification in welding fume was performed as a model assay. The results of multiple independent user testing gave mean absolute percentage error and average relative standard deviations of 10.5% and 11.2% respectively, which were an improvement over analysis based on simple visual color comparison with a read guide (12.2%, 14.9%). In addition to the analytical performance comparison, an interference study and a shelf life investigation were performed to further demonstrate practical utility. The developed system demonstrates an alternative detection approach for distance-based PADs enabling fast (∼10 min), quantitative, and straightforward assays.
Evaluation of machine learning algorithms for improved risk assessment for Down's syndrome.
Koivu, Aki; Korpimäki, Teemu; Kivelä, Petri; Pahikkala, Tapio; Sairanen, Mikko
2018-05-04
Prenatal screening generates a great amount of data that is used for predicting risk of various disorders. Prenatal risk assessment is based on multiple clinical variables and overall performance is defined by how well the risk algorithm is optimized for the population in question. This article evaluates machine learning algorithms to improve performance of first trimester screening of Down syndrome. Machine learning algorithms pose an adaptive alternative to develop better risk assessment models using the existing clinical variables. Two real-world data sets were used to experiment with multiple classification algorithms. Implemented models were tested with a third, real-world, data set and performance was compared to a predicate method, a commercial risk assessment software. Best performing deep neural network model gave an area under the curve of 0.96 and detection rate of 78% with 1% false positive rate with the test data. Support vector machine model gave area under the curve of 0.95 and detection rate of 61% with 1% false positive rate with the same test data. When compared with the predicate method, the best support vector machine model was slightly inferior, but an optimized deep neural network model was able to give higher detection rates with same false positive rate or similar detection rate but with markedly lower false positive rate. This finding could further improve the first trimester screening for Down syndrome, by using existing clinical variables and a large training data derived from a specific population. Copyright © 2018 Elsevier Ltd. All rights reserved.
Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari
2016-01-01
Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25–69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway. PMID:27073929
Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari
2016-01-01
Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.
Predicting Sepsis Risk Using the "Sniffer" Algorithm in the Electronic Medical Record.
Olenick, Evelyn M; Zimbro, Kathie S; DʼLima, Gabrielle M; Ver Schneider, Patricia; Jones, Danielle
The Sepsis "Sniffer" Algorithm (SSA) has merit as a digital sepsis alert but should be considered an adjunct to versus an alternative for the Nurse Screening Tool (NST), given lower specificity and positive predictive value. The SSA reduced the risk of incorrectly categorizing patients at low risk for sepsis, detected sepsis high risk in half the time, and reduced redundant NST screens by 70% and manual screening hours by 64% to 72%. Preserving nurse hours expended on manual sepsis alerts may translate into time directed toward other patient priorities.
Nasir, Muhammad Zafir Mohamad; Pumera, Martin
2016-10-12
Impact electrochemistry provides a useful alternative technique for the detection of silver nanoparticles in solutions. The combined use of impact electrochemistry on screen-printed electrodes (SPEs) for the successful detection of silver nanoparticles provides an avenue for future on-site, point-of-care detection devices to be made for environmental, medicinal and biological uses. Here we discuss the use of screen-printed electrodes for the detection of well-defined monodispersed silver nanoparticles of sizes 10, 20, 40, 80, and 107 nm.
2014-01-01
Background Colorectal cancer (CRC) is the second most prevalent type of cancer in Europe. A single flexible sigmoidoscopy (FS) screening at around the age of 60 years prevents about one-third of CRC cases. However, FS screens only the distal colon, and thus mortality from proximal CRC is unaffected. Computed tomography colonography (CTC) is a highly accurate examination that allows assessment of the entire colon. However, the benefit of CTC testing as a CRC screening test is uncertain. We designed a randomized trial to compare participation rate, detection rates, and costs between CTC (with computer-aided detection) and FS as primary tests for population-based screening. Methods/Design An invitation letter to participate in a randomized screening trial comparing CTC versus FS will be mailed to a sample of 20,000 people aged 58 or 60 years, living in the Piedmont region and the Verona district of Italy. Individuals with a history of CRC, adenomas, inflammatory bowel disease, or recent colonoscopy, or with two first-degree relatives with CRC will be excluded from the study by their general practitioners. Individuals responding positively to the invitation letter will be then randomized to the intervention group (CTC) or control group (FS), and scheduled for the screening procedure. The primary outcome parameter of this part of the trial is the difference in advanced neoplasia detection between the two screening tests. Secondary outcomes are cost-effectiveness analysis, referral rates for colonoscopy induced by CTC versus FS, and the expected and perceived burden of the procedures. To compare participation rates for CTC versus FS, 2,000 additional eligible subjects will be randomly assigned to receive an invitation for screening with CTC or FS. In the CTC arm, non-responders will be offered fecal occult blood test (FOBT) as alternative screening test, while in the FS arm, non-responders will receive an invitation letter to undergo screening with either FOBT or CTC. Data on reasons for participation and non-participation will also be collected. Discussion This study will provide reliable information concerning benefits and risks of the adoption of CTC as a mass screening intervention in comparison with FS. The trial will also evaluate the role of computer-aided detection in a screening setting. Trial registration ClinicalTrials.gov Identifier: NCT01739608 PMID:24678896
Martin, Todd M
2017-05-01
The goal of alternatives assessment (AA) is to facilitate a comparison of alternatives to a chemical of concern, resulting in the identification of safer alternatives. A two stage methodology for comparing chemical alternatives was developed. In the first stage, alternatives are compared using a variety of human health effects, ecotoxicity, and physicochemical properties. Hazard profiles are completed using a variety of online sources and quantitative structure activity relationship models. In the second stage, alternatives are evaluated utilizing an exposure/risk assessment over the entire life cycle. Exposure values are calculated using screening-level near-field and far-field exposure models. The second stage allows one to more accurately compare potential exposure to each alternative and consider additional factors that may not be obvious from separate binned persistence, bioaccumulation, and toxicity scores. The methodology was utilized to compare phosphate-based alternatives for decabromodiphenyl ether (decaBDE) in electronics applications.
Gaudin, Valerie; Juhel-Gaugain, Murielle; Morétain, Jean-Pierre; Sanders, Pascal
2008-12-01
Premi Test contains viable spores of a strain of Bacillus stearothermophilus which is sensitive to antimicrobial residues, such as beta-lactams, tetracyclines, macrolides and sulphonamides. The growth of the strain is inhibited by the presence of antimicrobial residues in muscle tissue samples. Premi Test was validated according to AFNOR rules (French Association for Normalisation). The AFNOR validation was based on the comparison of reference methods (French Official method, i.e. four plate test (FPT) and the STAR protocol (five plate test)) with the alternative method (Premi Test). A preliminary study was conducted in an expert laboratory (Community Reference Laboratory, CRL) on both spiked and incurred samples (field samples). Several method performance criteria (sensitivity, specificity, relative accuracy) were estimated and are discussed, in addition to detection capabilities. Adequate agreement was found between the alternative method and the reference methods. However, Premi Test was more sensitive to beta-lactams and sulphonamides than the FPT. Subsequently, a collaborative study with 11 laboratories was organised by the CRL. Blank and spiked meat juice samples were sent to participants. The expert laboratory (CRL) statistically analysed the results. It was concluded that Premi Test could be used for the routine determination of antimicrobial residues in muscle of different animal origin with acceptable analytical performance. The detection capabilities of Premi Test for beta-lactams (amoxicillin, ceftiofur), one macrolide (tylosin) and tetracycline were at the level of the respective maximum residue limits (MRL) in muscle samples or even lower.
Isolated colorectal cancer screening or integrated cancer prevention? A provocative suggestion!
Stockbrugger, Reinhold
2012-01-01
Colorectal cancer (CRC) screening is still not fully established in the European Union. Recently, the United European Gastroenterology Federation (UEGF) supported CRC screening with the publication of quality guidelines and a written declaration in the European Parliament in favor of European-wide monitored CRC screening and primary prevention of CRC, the latter particularly in young citizens. In this article, the need for population-based CRC screening is once again stressed. In addition, the value of opportunistic CRC screening is pointed out, either as a regional or nation-wide alternative (such as in the USA and Germany) or as a 'forerunner' activity in view of subsequent population-based CRC screening. With regard to other parallel organ-related screening activities in Europe (breast, uterus) and the increasing need for primary prevention of malignant and benign diseases, the question is raised as to whether preventive activities should not be recognized as an integrated and logical part of a 'healthcare chain' offered to all European citizens. Copyright © 2012 S. Karger AG, Basel.
Suedee, Roongnapa; Intakong, Wimon; Dickert, Franz L
2006-08-15
An alternative screening method for haloacetic acids (HAAs) disinfection by-products in drinking water is described. The method is based on the use of piezoelectric quartz crystal microbalance (QCM) transducing system, where the electrode is coated with a trichloacetic acid-molecularly imprinted polymer (TCAA-MIP). This MIP comprises a crosslinked poly(ethyleneglycoldimethacrylate-co-4-vinylpyridine). The coated QCM is able to specifically detect the analytes in water samples in terms of the mass change in relation to acid-base interactions of the analytes with the MIP. The TCAA-MIP coated QCM showed high specificity for the determination of TCAA in aqueous solutions containing inorganic anions, but its sensitivity reduced in water samples containing hydrochloric acid due to a mass loss at the sensor surface. Cross-reactivity studies with HAA analogs (dichloro-, monochloro-, tribromo-, dibromo-, and monobromo-acetic acids) and non-structurally related TCAA molecules (acetic acid and malonic acid) indicated that recognition of the structurally related TCAA compounds by the TCAA-MIP-based QCM is due to a carboxylic acid functional group, and probably involves a combination of both size and shape selectivity. The total response time of sensor is in the order of 10min. The achieved limits of detection for HAAs (20-50mugl(-1)) are at present higher than the actual concentrations found in real-life samples, but below the guidelines for the maximum permissible levels (60mugl(-1) for mixed HAAs). Recovery studies with drinking water samples spiked with TCAA or spiked with mixtures of HAAs revealed the reproducibility and precision of the method. The present work has demonstrated that the proposed assay can be a fast, reliable and inexpensive screening method for HAA contaminants in water samples, but further refinement is required to improve the limits of detection.
A risk/cost analysis of alternative screening intervals for occupational tuberculosis infection.
Nicas, M
1998-02-01
The Centers for Disease Control and Prevention (CDC) recommends that new health care employees receive a baseline skin test for Mycobacterium tuberculosis (M. tb) infection and that testing be repeated periodically. However, CDC does not explain the quantitative basis for its suggested screening intervals. This article examines the efficacy of alternative screening intervals for workers subject to different annual rates of M. tb infection and estimates the costs. An equation is developed for the cumulative risk of tuberculosis (TB) at 12 years given a specified annual rate of infection (ARI), screening interval, and a combined proportion (p) of successful skin testing and antibiotic prophylaxis. Equations for total cost of screening and cost per disease case prevented are provided. Results assume: (a) costs of $10 per skin test and $10,000 per TB disease case; (b) p = 0.88; and (c) and acceptable cumulative TB risk of 1 per 1000. For ARIs that might be deemed low (0.2% to 0.5%) and medium (1%), CDC screening intervals of 12 months and 6-12 months, respectively, minimize the cost per disease case prevented but permit residual disease risks greater than 1 per 1000. Recommended screening intervals are (i) 6 months for low-risk employee groups and (ii) 3 months for medium- and high-risk (e.g., ARIs of > or = 5%) groups. Interval (i) limits risk to 1 per 1000 and is approximately 50% shorter than the CDC interval for a low-risk group. Interval (ii), which is 67% shorter than the CDC interval for medium-risk groups but equal to that recommended for high-risk groups, permits a risk above 1 per 1000, but is likely the shortest feasible interval.
NASA Astrophysics Data System (ADS)
Kelouaz, Moussa; Ouazir, Youcef; Hadjout, Larbi; Mezani, Smail; Lubin, Thiery; Berger, Kévin; Lévêque, Jean
2018-05-01
In this paper a new superconducting inductor topology intended for synchronous machine is presented. The studied machine has a standard 3-phase armature and a new kind of 2-poles inductor (claw-pole structure) excited by two coaxial superconducting coils. The air-gap spatial variation of the radial flux density is obtained by inserting a superconducting bulk, which deviates the magnetic field due to the coils. The complex geometry of this inductor usually needs 3D finite elements (FEM) for its analysis. However, to avoid a long computational time inherent to 3D FEM, we propose in this work an alternative modeling, which uses a 3D meshed reluctance network. The results obtained with the developed model are compared to 3D FEM computations as well as to measurements carried out on a laboratory prototype. Finally, a 3D FEM study of the shielding properties of the superconducting screen demonstrates the suitability of using a diamagnetic-like model of the superconducting screen.
Osbourn, Gordon C.
1996-01-01
The shadow contrast sensitivity of the human vision system is simulated by configuring information obtained from an image sensor so that the information may be evaluated with multiple pixel widths in order to produce a machine vision system able to distinguish between shadow edges and abrupt object edges. A second difference of the image intensity for each line of the image is developed and this second difference is used to screen out high frequency noise contributions from the final edge detection signals. These edge detection signals are constructed from first differences of the image intensity where the screening conditions are satisfied. The positional coincidence of oppositely signed maxima in the first difference signal taken from the right and the second difference signal taken from the left is used to detect the presence of an object edge. Alternatively, the effective number of responding operators (ENRO) may be utilized to determine the presence of object edges.
Peng, Tianyuan; Wooke, Zachary; Pohl, Nicola L B
2018-03-22
Acidic hydrolysis is commonly used as a first step to break down oligo- and polysaccharides into monosaccharide units for structural analysis. While easy to set up and amenable to mass spectrometry detection, acid hydrolysis is not without its drawbacks. For example, ring-destruction side reactions and degradation products, along with difficulties in optimizing conditions from analyte to analyte, greatly limits its broad utility. Herein we report studies on a hydrogen peroxide/CuGGH metallopeptide-based glycosidase mimetic design for a more efficient and controllable carbohydrate hydrolysis. A library of methyl glycosides consisting of ten common monosaccharide substrates, along with oligosaccharide substrates, was screened with the artificial glycosidase for hydrolytic activity in a high-throughput format with a robotic liquid handling system. The artificial glycosidase was found to be active towards most screened linkages, including alpha- and beta-anomers, thus serving as a potential alternative method for traditional acidic hydrolysis approaches of oligosaccharides. Copyright © 2018 Elsevier Ltd. All rights reserved.
Legrain, Fleur; Carrete, Jesús; van Roekeghem, Ambroise; Madsen, Georg K H; Mingo, Natalio
2018-01-18
Machine learning (ML) is increasingly becoming a helpful tool in the search for novel functional compounds. Here we use classification via random forests to predict the stability of half-Heusler (HH) compounds, using only experimentally reported compounds as a training set. Cross-validation yields an excellent agreement between the fraction of compounds classified as stable and the actual fraction of truly stable compounds in the ICSD. The ML model is then employed to screen 71 178 different 1:1:1 compositions, yielding 481 likely stable candidates. The predicted stability of HH compounds from three previous high-throughput ab initio studies is critically analyzed from the perspective of the alternative ML approach. The incomplete consistency among the three separate ab initio studies and between them and the ML predictions suggests that additional factors beyond those considered by ab initio phase stability calculations might be determinant to the stability of the compounds. Such factors can include configurational entropies and quasiharmonic contributions.
Phytochemical screening and antioxidant capacity of the aerial parts of Thymelaea hirsuta L.
Amari, Nesrine Ouda; Bouzouina, Mohamed; Berkani, Abdellah; Lotmani, Brahim
2014-01-01
Objective To assess antioxidant activities of different aerial parts of Thymelaea hirsuta (T. hirsuta) from west Algeria, and to search for new sources of safe and inexpensive antioxidants. Methods Samples of leaves, stems and flowers from T. hirsuta were tested for total phenolic content, flavonoids content, and evaluation its total antioxidant activity, were done using the spectrophotometric analyses. Results Results of preliminary phytochemical screening of leaf, flower and stem of T. hirsuta revealed the presence of tannins, alkaloids, steroids, saponins, coumarins, reducteurs compound and anthraquinones. The total phenolics and flavonoids were estimated. The aqueous extracts of the aerial parts of T. hirsuta showed potent in vitro antioxydant activities using various models viz, DPPH scavenging assay, ferric reducing antioxidant power (FRAP) and ABTS radical scavenging activity. Conclusions On the basis of the results obtained, T. hirsuta extracts are rich sources of natural antioxidants appears to be an alternative to synthetic antioxidants and this justifies its therapeutic usage.
Basavanna, Uma; Muruvanda, Tim; Brown, Eric W.; Sharma, Shashi K.
2013-01-01
The standard procedure for definitive detection of BoNT-producing Clostridia is a culture method combined with neurotoxin detection using a standard mouse bioassay (MBA). The mouse bioassay is highly sensitive and specific, but it is expensive and time-consuming, and there are ethical concerns due to use of laboratory animals. Cell-based assays provide an alternative to the MBA in screening for BoNT-producing Clostridia. Here, we describe a cell-based assay utilizing a fluorescence reporter construct expressed in a neuronal cell model to study toxin activity in situ. Our data indicates that the assay can detect as little as 100 pM BoNT/A activity within living cells, and the assay is currently being evaluated for the analysis of BoNT in food matrices. Among available in vitro assays, we believe that cell-based assays are widely applicable in high-throughput screenings and have the potential to at least reduce and refine animal assays if not replace it. PMID:23533420
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hargesheimer, E.E.
Methane chemical ionization (CI)-selected ion monitoring (SIM) mass spectrometry was used to identify and conclusively distinguish 19 organochlorine pesticides from polychlorinated biphenyls (PCBs) at parts-per-trillion to parts-per-billion levels in environmental water sample extracts with minimal sample cleanup. Two CI-SIM screens were developed. One set of ions scanned specifically for the presence of 4 classes of pesticides; diphenylmethane derivatives, bridged polycyclic chlorinated benzenes, and acetanilide pesticides. The second set of ions responded exclusively to PCBs with biphenyl moieties containing from 1 to 8 chlorine atoms. Eight commercial Aroclor mixtures were analyzed and distinguished from the pesticides groups. The detection limit formore » pesticides and PCBs by CI-SIM screening was 0.005 and 0.1 ppB, respectively. CI-SIM can be used as an alternative method for the analysis of biological or environmental samples containing interferences that complicate the detection of PCBs and chlorinated pesticides. 8 references, 6 figures, 6 tables.« less
Hoenigl, Martin; Graff-Zivin, Joshua; Little, Susan J.
2016-01-01
Background. In nonhealthcare settings, widespread screening for acute human immunodeficiency virus (HIV) infection (AHI) is limited by cost and decision algorithms to better prioritize use of resources. Comparative cost analyses for available strategies are lacking. Methods. To determine cost-effectiveness of community-based testing strategies, we evaluated annual costs of 3 algorithms that detect AHI based on HIV nucleic acid amplification testing (EarlyTest algorithm) or on HIV p24 antigen (Ag) detection via Architect (Architect algorithm) or Determine (Determine algorithm) as well as 1 algorithm that relies on HIV antibody testing alone (Antibody algorithm). The cost model used data on men who have sex with men (MSM) undergoing community-based AHI screening in San Diego, California. Incremental cost-effectiveness ratios (ICERs) per diagnosis of AHI were calculated for programs with HIV prevalence rates between 0.1% and 2.9%. Results. Among MSM in San Diego, EarlyTest was cost-savings (ie, ICERs per AHI diagnosis less than $13.000) when compared with the 3 other algorithms. Cost analyses relative to regional HIV prevalence showed that EarlyTest was cost-effective (ie, ICERs less than $69.547) for similar populations of MSM with an HIV prevalence rate >0.4%; Architect was the second best alternative for HIV prevalence rates >0.6%. Conclusions. Identification of AHI by the dual EarlyTest screening algorithm is likely to be cost-effective not only among at-risk MSM in San Diego but also among similar populations of MSM with HIV prevalence rates >0.4%. PMID:26508512
Khwankong, Srisuk; Sriplung, Hutcha; Kerdpon, Duangporn
2018-06-01
Oral cancer is one of the leading cancers in Thailand; southern Thai Muslims seem to have a longer delay in attending treatment for oral cancer than Buddhists in the same area. Visual screenings of high-risk populations have been suggested to be an effective prevention method. This study assessed oral cancer knowledge and belief attitudes influencing oral cancer screening in Thai Muslim high-risk groups. Twelve semi-structured in-depth interviews and the focus group discussion were conducted based on the health belief model. Stratified purposeful sampling was used to recruit the participants. Inclusion criteria were those who practiced the risk habits for oral cancer and were 40 years of age or older, smokers (20+ cigarettes per day for at least 20 years) and/or betel quid chewers (10+ times per day for at least 10 years). Participants lacked knowledge about oral cancer in terms of signs and symptoms and predisposing factors. This influenced misleading belief attitudes concerning susceptibility of oral cancer, barriers, and their self-efficacy to have oral cancer screening examinations. Betel quid chewing was not regarded as a risk habit but as having a protective role against the disease. Perceived susceptibility was also seen by some to be dependent upon Allah's will. Traditional medication was mentioned as a preferred alternative to modern treatment. The latter was believed by some to be the cause of death for cancer patients. Interventions to promote oral cancer knowledge and right belief attitudes for oral cancer screening are clearly indicated.
Amar, Natalie; Peretz, Avi; Gerchman, Yoram
2017-02-01
Helicobacter pylori is the most frequent and persistent bacterial infection worldwide, and a risk factor for active gastritis, peptic ulcers, mucosa-associated lymphoid tissue lymphoma, and gastric cancer. Although combined antibiotics treatment is effective cases of antibiotic resistance are reported at an alarming rate. The H. pylori urease enzyme is essential for the bacteria establishment in the gastric mucosa, resulting urease inhibitors being sought after as effective and specific anti- H. pylori treatment. To-date, screening assays are based mostly on the analog plant urease enzyme but difference in properties of the plant and bacterial enzymes hamper these efforts. We have developed a screening assay based on recombinant Escherichia coli expressing native H. pylori urease, and validated this assay using thiourea and a methanolic extract of Pistacia atlantica. The assay demonstrated the thiourea and the extract to be potent urease inhibitors, with the extract having strong bacteriostatic activity against clinical isolates of H. pylori, including such with antibiotic resistance. The extract was also found to be neutral toward common probiotic bacteria, supporting its specificity and compatibility with digestive system desired microflora and suggesting it could be a good source for anti-H. pylori compounds. The assay has proven to be cheap, simple and native alternative to the plant enzyme based assay and could allow for high throughput screening for new urease inhibitors and could expedite screening and development of novel, better H. pylori remedies helping us to combat this infection. Copyright © 2016 Elsevier B.V. All rights reserved.
Managing honey bees (Hymenoptera: Apidae) for greenhouse tomato pollination.
Sabara, Holly A; Winston, Mark L
2003-06-01
Although commercially reared colonies of bumble bees (Bombus sp.) are the primary pollinator world-wide for greenhouse tomatoes (Lycopersicon esculentum Mill.) previous research indicates that honey bees (Apis mellifera L.) might be a feasible alternative or supplement to bumble bee pollination. However, management methods for honey bee greenhouse tomato pollination scarcely have been explored. We 1) tested the effect of initial amounts of brood on colony population size and flight activity in screened greenhouses during the winter, and 2) compared foraging from colonies with brood used within screened and unscreened greenhouses during the summer. Brood rearing was maintained at low levels in both brood and no-brood colonies after 21 d during the winter, and emerging honey bees from both treatments had significantly lower weights than bees from outdoor colonies. Honey bee flight activity throughout the day and over the 21 d in the greenhouse was not influenced by initial brood level. In our summer experiment, brood production in screened greenhouses neared zero after 21 d but higher levels of brood were reared in unscreened greenhouses with access to outside forage. Flower visitation measured throughout the day and over the 21 d the colonies were in the greenhouse was not influenced by screening treatment. An economic analysis indicated that managing honey bees for greenhouse tomato pollination would be financially viable for both beekeepers and growers. We conclude that honey bees can be successfully managed for greenhouse tomato pollination in both screened and unscreened greenhouses if the foraging force is maintained by replacing colonies every 3 wk.
Aviation Security: Vulnerabilities in, and Alternatives for, Preboard Screening Security Operations
2001-09-25
establishing the certification program. This regulation is particularly significant because it is to include requirements mandated by the Airport Security Improvement...Assessment of Airport Security Screener Performance and Retention, Sept. 15, 2000. Page 8 GAO-01-1171T Criteria for Assessing Shifting responsibility for...airline and airport security officials to assess each option for reassigning screening responsibility against the key criteria- Specifically, we asked
Krause, David A; Boyd, Michael S; Hager, Allison N; Smoyer, Eric C; Thompson, Anthony T; Hollman, John H
2015-02-01
The squat is a fundamental movement of many athletic and daily activities. Methods to clinically assess the squat maneuver range from simple observation to the use of sophisticated equipment. The purpose of this study was to examine the reliability of Coach's Eye (TechSmith Corp), a 2-dimensional (2D) motion analysis mobile device application (app), for assessing maximal sagittal plane hip, knee, and ankle motion during a functional movement screen deep squat, and to compare range of motion values generated by it to those from a Vicon (Vicon Motion Systems Ltd) 3-dimensional (3D) motion analysis system. Twenty-six healthy subjects performed three functional movement screen deep squats recorded simultaneously by both the app (on an iPad [Apple Inc]) and the 3D motion analysis system. Joint angle data were calculated with Vicon Nexus software (Vicon Motion Systems Ltd). The app video was analyzed frame by frame to determine, and freeze on the screen, the deepest position of the squat. With a capacitive stylus reference lines were then drawn on the iPad screen to determine joint angles. Procedures were repeated with approximately 48 hours between sessions. Test-retest intrarater reliability (ICC3,1) for the app at the hip, knee, and ankle was 0.98, 0.98, and 0.79, respectively. Minimum detectable change was hip 6°, knee 6°, and ankle 7°. Hip joint angles measured with the 2D app exceeded measurements obtained with the 3D motion analysis system by approximately 40°. Differences at the knee and ankle were of lower magnitude, with mean differences of 5° and 3°, respectively. Bland-Altman analysis demonstrated a systematic bias in the hip range-of-motion measurement. No such bias was demonstrated at the knee or ankle. The 2D app demonstrated excellent reliability and appeared to be a responsive means to assess for clinical change, with minimum detectable change values ranging from 6° to 7°. These results also suggest that the 2D app may be used as an alternative to a sophisticated 3D motion analysis system for assessing sagittal plane knee and ankle motion; however, it does not appear to be a comparable alternative for assessing hip motion. 3.
Congenital syphilis: refining newborn evaluation and management in Shenzhen, southern China.
Wu, Da-Dong; Hong, Fu-Chang; Feng, Tie-Jian; Liu, Xiao-Li; Lin, Li-Jun; Tian, Li-Shan; Qiu, Li-Xia
2010-08-01
Consistent definitions of congenital syphilis are critical for determining true incidences and setting up targets of elimination. This study aimed to assess the evaluation and management of infants at high risk of congenital syphilis with an antenatal syphilis-screening programme in the Shenzhen SEZ and to develop feasible definitions for the detection of congenital syphilis in China. A retrospective study was conducted of all standardised records of pregnant women with positive syphilis between 2003 and 2007. Infants at high risk of congenital syphilis were evaluated by laboratory tests at birth and longitudinal follow-up. A screening test-positive congenital syphilis case was defined based on a positive 19S-IgM-FTA-ABS result at birth. Assuming that 19S-IgM-FTA-ABS was the gold standard, the sensitivity and specificity of the ascertainment methods were calculated. During the study period, 1010 live infants were born to women with active syphilis during pregnancy. 19S-IgM-FTA-ABS detected 42 screening-positive congenital syphilis cases and another nine cases were identified by longitudinal follow-up only. Using 19S-IgM-FTA-ABS as the gold standard, 'fourfold rapid plasma reagin (RPR) titres' had the highest sensitivity and specificity compared with the other two follow-up methods. 19S-IgM-FTA-ABS makes congenital syphilis case classification simpler and faster for newborns. In areas where 19S-IgM-FTA-ABS is not available, comparing newborn RPR titres with maternal titres can be an alternative method. Meanwhile, positive follow-up results act as treatment indicators for older infants. As congenital syphilis definitions vary over the country, the Shenzhen programme suggested a practical model for surveillance and treatment in areas with or without available 19S-IgM-FTA-ABS testing.
Ponce, Camille; Kaczorowski, Flora; Perpoint, Thomas; Miailhes, Patrick; Sigal, Alain; Javouhey, Etienne; Gillet, Yves; Jacquin, Laurent; Douplat, Marion; Tazarourte, Karim; Potinet, Véronique; Simon, Bruno; Lavoignat, Adeline; Bonnot, Guillaume; Sow, Fatimata; Bienvenu, Anne-Lise; Picot, Stéphane
2017-01-01
Background: Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. Results: 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. Conclusion: High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method. PMID:29251261
Extended screened exchange functional derived from transcorrelated density functional theory.
Umezawa, Naoto
2017-09-14
We propose a new formulation of the correlation energy functional derived from the transcorrelated method in use in density functional theory (TC-DFT). An effective Hamiltonian, H TC , is introduced by a similarity transformation of a many-body Hamiltonian, H, with respect to a complex function F: H TC =1FHF. It is proved that an expectation value of H TC for a normalized single Slater determinant, D n , corresponds to the total energy: E[n] = ⟨Ψ n |H|Ψ n ⟩/⟨Ψ n |Ψ n ⟩ = ⟨D n |H TC |D n ⟩ under the two assumptions: (1) The electron density nr associated with a trial wave function Ψ n = D n F is v-representable and (2) Ψ n and D n give rise to the same electron density nr. This formulation, therefore, provides an alternative expression of the total energy that is useful for the development of novel correlation energy functionals. By substituting a specific function for F, we successfully derived a model correlation energy functional, which resembles the functional form of the screened exchange method. The proposed functional, named the extended screened exchange (ESX) functional, is described within two-body integrals and is parametrized for a numerically exact correlation energy of the homogeneous electron gas. The ESX functional does not contain any ingredients of (semi-)local functionals and thus is totally free from self-interactions. The computational cost for solving the self-consistent-field equation is comparable to that of the Hartree-Fock method. We apply the ESX functional to electronic structure calculations for a solid silicon, H - ion, and small atoms. The results demonstrate that the TC-DFT formulation is promising for the systematic improvement of the correlation energy functional.
Direct screening of herbal blends for new synthetic cannabinoids by MALDI-TOF MS.
Gottardo, Rossella; Chiarini, Anna; Dal Prà, Ilaria; Seri, Catia; Rimondo, Claudia; Serpelloni, Giovanni; Armato, Ubaldo; Tagliaro, Franco
2012-01-01
Since 2004, a number of herbal blends containing different synthetic compounds mimicking the pharmacological activity of cannabinoids and displaying a high toxicological potential have appeared in the market. Their availability is mainly based on the so-called "e-commerce", being sold as legal alternatives to cannabis and cannabis derivatives. Although highly selective, sensitive, accurate, and quantitative methods based on GC-MS and LC-MS are available, they lack simplicity, rapidity, versatility and throughput, which are required for product monitoring. In this context, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) offers a simple and rapid operation with high throughput. Thus, the aim of the present work was to develop a MALDI-TOF MS method for the rapid qualitative direct analysis of herbal blend preparations for synthetic cannabinoids to be used as front screening of confiscated clandestine preparations. The sample preparation was limited to herbal blend leaves finely grinding in a mortar and loading onto the MALDI plate followed by addition of 2 µl of the matrix/surfactant mixture [α-cyano-4-hydroxy-cinnamic acid/cetyltrimethylammonium bromide (CTAB)]. After drying, the sample plate was introduced into the ion source for analysis. MALDI-TOF conditions were as follows: mass spectra were analyzed in the range m/z 150-550 by averaging the data from 50 laser shots and using an accelerating voltage of 20 kV. The described method was successfully applied to the screening of 31 commercial herbal blends, previously analyzed by GC-MS. Among the samples analyzed, 21 contained synthetic cannabinoids (namely JWH-018, JWH-073, JWH-081, JWH-250, JWH-210, JWH-019, and AM-694). All the results were in agreement with GC-MS, which was used as the reference technique. Copyright © 2012 John Wiley & Sons, Ltd.
Impact of single particle oscillations on screening of a test charge
NASA Astrophysics Data System (ADS)
Ramazanov, Tlekkabul S.; Moldabekov, Zhandos A.; Gabdullin, Maratbek T.
2018-06-01
Screening of a test charge by electrons oscillating in an external alternating electrical (laser) field is analyzed. It is shown that single particle oscillations lead to the creation of an oscillatory pattern of the test charge's potential at large distances. Analysis has been done by considering and neglecting the contribution of ions on the screening. Impact of the quantum diffraction (non-locality) and of the collisional damping on the test charge's potential is considered. It is shown that electrons are unable to provide screening of the test charge if the frequency of the induced single particle oscillations larger than the electron-plasma frequency. In the opposite case of low frequencies, the potential of the test charge changes its sign if the screening by ions is neglected.
An NCI database that contains the latest information about cancer treatment, screening, prevention, genetics, supportive care, and complementary and alternative medicine, plus drug information and a dictionary of cancer terms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tessore, Nicolas; Metcalf, R. Benton; Winther, Hans A.
A number of alternatives to general relativity exhibit gravitational screening in the non-linear regime of structure formation. We describe a set of algorithms that can produce weak lensing maps of large scale structure in such theories and can be used to generate mock surveys for cosmological analysis. By analysing a few basic statistics we indicate how these alternatives can be distinguished from general relativity with future weak lensing surveys.
2014-01-01
Background The AUDIT-C is an extensively validated screen for unhealthy alcohol use (i.e. drinking above recommended limits or alcohol use disorder), which consists of three questions about alcohol consumption. AUDIT-C scores ≥4 points for men and ≥3 for women are considered positive screens based on US validation studies that compared the AUDIT-C to “gold standard” measures of unhealthy alcohol use from independent, detailed interviews. However, results of screening—positive or negative based on AUDIT-C scores—can be inconsistent with reported drinking on the AUDIT-C questions. For example, individuals can screen positive based on the AUDIT-C score while reporting drinking below US recommended limits on the same AUDIT-C. Alternatively, they can screen negative based on the AUDIT-C score while reporting drinking above US recommended limits. Such inconsistencies could complicate interpretation of screening results, but it is unclear how often they occur in practice. Methods This study used AUDIT-C data from respondents who reported past-year drinking on one of two national US surveys: a general population survey (N = 26,610) and a Veterans Health Administration (VA) outpatient survey (N = 467,416). Gender-stratified analyses estimated the prevalence of AUDIT-C screen results—positive or negative screens based on the AUDIT-C score—that were inconsistent with reported drinking (above or below US recommended limits) on the same AUDIT-C. Results Among men who reported drinking, 13.8% and 21.1% of US general population and VA samples, respectively, had screening results based on AUDIT-C scores (positive or negative) that were inconsistent with reported drinking on the AUDIT-C questions (above or below US recommended limits). Among women who reported drinking, 18.3% and 20.7% of US general population and VA samples, respectively, had screening results that were inconsistent with reported drinking. Limitations This study did not include an independent interview gold standard for unhealthy alcohol use and therefore cannot address how often observed inconsistencies represent false positive or negative screens. Conclusions Up to 21% of people who drink alcohol had alcohol screening results based on the AUDIT-C score that were inconsistent with reported drinking on the same AUDIT-C. This needs to be addressed when training clinicians to use the AUDIT-C. PMID:24468406
Ghanouni, Alex; Renzi, Cristina; Waller, Jo
2017-04-18
There is broad agreement that cancer screening invitees should know the risks and benefits of testing before deciding whether to participate. In organised screening programmes, a primary method of relaying this information is via leaflets provided at the time of invitation. Little is known about why individuals do not engage with this information. This study assessed factors associated with reading information leaflets provided by the three cancer screening programmes in England. A cross-sectional survey asked screening-eligible members of the general population in England about the following predictor variables: uptake of previous screening invitations, demographic characteristics, and 'decision-making styles' (i.e. the extent to which participants tended to make decisions in a way that was avoidant, rational, intuitive, spontaneous, or dependent). The primary outcome measures were the amount of the leaflet that participants reported having read at their most recent invitation, for any of the three programmes for which they were eligible. Associations between these outcomes and predictor variables were assessed using binary or ordinal logistic regression. After exclusions, data from 275, 309, and 556 participants were analysed in relation to the breast, cervical, and bowel screening programmes, respectively. Notable relationships included associations between regularity of screening uptake and reading (more of) the information leaflets for all programmes (e.g. odds ratio: 0.16 for participants who never/very rarely attended breast screening vs. those who always attended previously; p = .009). Higher rational decision-making scores were associated with reading more of the cervical and bowel screening leaflets (OR: 1.13, p < .0005 and OR: 1.11, p = .045, respectively). Information engagement was also higher for White British participants compared with other ethnic groups for breast (OR: 3.28, p = .008) and bowel (OR: 2.58, p = .015) information; an opposite relationship was observed for older participants (OR: 0.96, p = .048; OR: 0.92, p = .029). Interventions that increase screening uptake may also increase subsequent engagement with information. Future research could investigate how to improve engagement at initial invitations. There may also be scope to reduce barriers to accessing non-English information and alternative communication strategies may benefit participants who are less inclined to weigh up advantages and disadvantages as part of their decision-making.
Recent trends in SELEX technique and its application to food safety monitoring
Mei, Zhanlong; Yao, Li; Wang, Xin; Zheng, Lei; Liu, Jian; Liu, Guodong; Peng, Chifang; Chen, Wei
2014-01-01
The method referred to as “systemic evolution of ligands by exponential enrichment” (SELEX) was introduced in 1990 and ever since has become an important tool for the identification and screening of aptamers. Such nucleic acids can recognize and bind to their corresponding targets (analytes) with high selectivity and affinity, and aptamers therefore have become attractive alternatives to traditional antibodies not the least because they are much more stable. Meanwhile, they have found numerous applications in different fields including food quality and safety monitoring. This review first gives an introduction into the selection process and to the evolution of SELEX, then covers applications of aptamers in the surveillance of food safety (with subsections on absorptiometric, electrochemical, fluorescent and other methods), and then gives conclusions and perspectives. The SELEX method excels by its features of in vitro, high throughput and ease of operation. This review contains 86 references. PMID:25419005
Immunoanalysis Methods for the Detection of Dioxins and Related Chemicals
Tian, Wenjing; Xie, Heidi Qunhui; Fu, Hualing; Pei, Xinhui; Zhao, Bin
2012-01-01
With the development of biotechnology, approaches based on antibodies, such as enzyme-linked immunosorbent assay (ELISA), active aryl hydrocarbon immunoassay (Ah-I) and other multi-analyte immunoassays, have been utilized as alternatives to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of dioxin and dioxin-like compounds in environmental and biological samples. These screening methods have been verified as rapid, simple and cost-effective. This paper provides an overview on the development and application of antibody-based approaches, such as ELISA, Ah-I, and multi-analyte immunoassays, covering the sample extraction and cleanup, antigen design, antibody preparation and immunoanalysis. However, in order to meet the requirements for on-site fast detection and relative quantification of dioxins in the environment, further optimization is needed to make these immuno-analytical methods more sensitive and easy to use. PMID:23443395
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert Boehlecke
2004-04-01
The six bunkers included in CAU 204 were primarily used to monitor atmospheric testing or store munitions. The ''Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 204: Storage Bunkers, Nevada Test Site, Nevada'' (NNSA/NV, 2002a) provides information relating to the history, planning, and scope of the investigation; therefore, it will not be repeated in this CADD. This CADD identifies potential corrective action alternatives and provides a rationale for the selection of a recommended corrective action alternative for each CAS within CAU 204. The evaluation of corrective action alternatives is based on process knowledge and the results of investigative activitiesmore » conducted in accordance with the CAIP (NNSA/NV, 2002a) that was approved prior to the start of the Corrective Action Investigation (CAI). Record of Technical Change (ROTC) No. 1 to the CAIP (approval pending) documents changes to the preliminary action levels (PALs) agreed to by the Nevada Division of Environmental Protection (NDEP) and DOE, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). This ROTC specifically discusses the radiological PALs and their application to the findings of the CAU 204 corrective action investigation. The scope of this CADD consists of the following: (1) Develop corrective action objectives; (2) Identify corrective action alternative screening criteria; (3) Develop corrective action alternatives; (4) Perform detailed and comparative evaluations of corrective action alternatives in relation to corrective action objectives and screening criteria; and (5) Recommend and justify a preferred corrective action alternative for each CAS within CAU 204.« less
Real-time 3-D X-ray and gamma-ray viewer
NASA Technical Reports Server (NTRS)
Yin, L. I. (Inventor)
1983-01-01
A multi-pinhole aperture lead screen forms an equal plurality of invisible mini-images having dissimilar perspectives of an X-ray and gamma-ray emitting object (ABC) onto a near-earth phosphor layer. This layer provides visible light mini-images directly into a visible light image intensifier. A viewing screen having an equal number of dissimilar perspective apertures distributed across its face in a geometric pattern identical to the lead screen, provides a viewer with a real, pseudoscopic image (A'B'C') of the object with full horizontal and vertical parallax. Alternatively, a third screen identical to viewing screen and spaced apart from a second visible light image intensifier, may be positioned between the first image intensifier and the viewing screen, thereby providing the viewer with a virtual, orthoscopic image (A"B"C") of the object (ABC) with full horizontal and vertical parallax.
Peer-reviewed, evidence-based summaries on topics including adult and pediatric cancer treatment, supportive and palliative care, screening, prevention, genetics, and complementary and alternative medicine. References to published literature are included.