40 CFR 136.5 - Approval of alternate test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and to the Alternate Test Procedure Program Coordinator, Office of Science and Technology (4303... to the Alternate Test Procedure Program Coordinator, Office of Science and Technology (4303), Office... will be forwarded to the Alternate Test Procedure Program Coordinator, Office of Science and Technology...
40 CFR 136.5 - Approval of alternate test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and to the Alternate Test Procedure Program Coordinator, Office of Science and Technology (4303... to the Alternate Test Procedure Program Coordinator, Office of Science and Technology (4303), Office... will be forwarded to the Alternate Test Procedure Program Coordinator, Office of Science and Technology...
19 CFR 101.9 - Test programs or procedures; alternate requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2014-04-01 2014-04-01 false Test programs or procedures; alternate... SECURITY; DEPARTMENT OF THE TREASURY GENERAL PROVISIONS § 101.9 Test programs or procedures; alternate...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Use of alternate apparatus, procedures, or... Rules and Regulations § 1610.40 Use of alternate apparatus, procedures, or criteria for tests for... 1610 prescribes apparatus and procedures for testing fabrics and garments subject to its provisions...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Use of alternate apparatus, procedures, or... Rules and Regulations § 1610.40 Use of alternate apparatus, procedures, or criteria for tests for... 1610 prescribes apparatus and procedures for testing fabrics and garments subject to its provisions...
19 CFR 101.9 - Test programs or procedures; alternate requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2010-04-01 2010-04-01 false Test programs or procedures; alternate...
19 CFR 101.9 - Test programs or procedures; alternate requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2013-04-01 2013-04-01 false Test programs or procedures; alternate...
19 CFR 101.9 - Test programs or procedures; alternate requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2011-04-01 2011-04-01 false Test programs or procedures; alternate...
19 CFR 101.9 - Test programs or procedures; alternate requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2012-04-01 2012-04-01 false Test programs or procedures; alternate...
16 CFR 1616.36 - Use of alternate apparatus or procedures for tests for guaranty purposes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Use of alternate apparatus or procedures for... THROUGH 14 (FF 5-74) Rules and Regulations § 1616.36 Use of alternate apparatus or procedures for tests... Commission has set forth conditions under which the Commission will approve the use of test apparatus or...
16 CFR 1615.36 - Use of alternate apparatus or procedures for tests for guaranty purposes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Use of alternate apparatus or procedures for... THROUGH 6X (FF 3-71) Rules and Regulations § 1615.36 Use of alternate apparatus or procedures for tests... Commission has set forth conditions under which the Commission will approve the use of test apparatus or...
16 CFR 1615.36 - Use of alternate apparatus or procedures for tests for guaranty purposes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Use of alternate apparatus or procedures for... THROUGH 6X (FF 3-71) Rules and Regulations § 1615.36 Use of alternate apparatus or procedures for tests... Commission has set forth conditions under which the Commission will approve the use of test apparatus or...
16 CFR 1616.36 - Use of alternate apparatus or procedures for tests for guaranty purposes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Use of alternate apparatus or procedures for... THROUGH 14 (FF 5-74) Rules and Regulations § 1616.36 Use of alternate apparatus or procedures for tests... Commission has set forth conditions under which the Commission will approve the use of test apparatus or...
16 CFR 1616.35 - Use of alternate apparatus, procedures, or criteria for testing under the standard.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Use of alternate apparatus, procedures, or...: SIZES 7 THROUGH 14 (FF 5-74) Rules and Regulations § 1616.35 Use of alternate apparatus, procedures, or... apparatus and procedure for performing tests of fabric and garments subject to its provisions. See 16 CFR...
16 CFR 1616.35 - Use of alternate apparatus, procedures, or criteria for testing under the standard.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Use of alternate apparatus, procedures, or...: SIZES 7 THROUGH 14 (FF 5-74) Rules and Regulations § 1616.35 Use of alternate apparatus, procedures, or... apparatus and procedure for performing tests of fabric and garments subject to its provisions. See 16 CFR...
16 CFR 1615.35 - Use of alternate apparatus, procedures, or criteria for testing under the standard.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Use of alternate apparatus, procedures, or...: SIZES 0 THROUGH 6X (FF 3-71) Rules and Regulations § 1615.35 Use of alternate apparatus, procedures, or... prescribes an apparatus and procedure for performing tests of fabric and garments subject to its provisions...
16 CFR 1615.35 - Use of alternate apparatus, procedures, or criteria for testing under the standard.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Use of alternate apparatus, procedures, or...: SIZES 0 THROUGH 6X (FF 3-71) Rules and Regulations § 1615.35 Use of alternate apparatus, procedures, or... prescribes an apparatus and procedure for performing tests of fabric and garments subject to its provisions...
Alternator insulation evaluation tests
NASA Technical Reports Server (NTRS)
Penn, W. B.; Schaefer, R. F.; Balke, R. L.
1972-01-01
Tests were conducted to predict the remaining electrical insulation life of a 60 KW homopolar inductor alternator following completion of NASA turbo-alternator endurance tests for SNAP-8 space electrical power systems application. The insulation quality was established for two alternators following completion of these tests. A step-temperature aging test procedure was developed for insulation life prediction and applied to one of the two alternators. Armature winding insulation life of over 80,000 hours for an average winding temperature of 248 degrees C was predicted using the developed procedure.
21 CFR 352.77 - Test modifications.
Code of Federal Regulations, 2010 CFR
2010-04-01
... modification of the testing procedures in this subpart. In addition, alternative methods (including automated or in vitro procedures) employing the same basic procedures as those described in this subpart may be used. Any proposed modification or alternative procedure shall be submitted as a petition in accord...
21 CFR 352.77 - Test modifications.
Code of Federal Regulations, 2011 CFR
2011-04-01
... modification of the testing procedures in this subpart. In addition, alternative methods (including automated or in vitro procedures) employing the same basic procedures as those described in this subpart may be used. Any proposed modification or alternative procedure shall be submitted as a petition in accord...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-30
... amendments to its evaporative emission test procedures, four-wheel drive dynamometer provisions, and vehicle... manufacturer has certified vehicles using an alternative running loss test procedure, CARB may conduct... manufacturer's approved alternative running loss test procedure; (3) provide manufacturers an option to use an...
40 CFR 85.1414 - Alternative test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Alternative test procedures. 85.1414 Section 85.1414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Urban Bus Rebuild Requirements § 85.1414 Alternative...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... allow. (2) The degree to which the alternate procedure affects your ability to show that your engines...
40 CFR 80.177 - Certification test fuels for use with the alternative test procedures and standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Certification test fuels for use with... Detergent Gasoline § 80.177 Certification test fuels for use with the alternative test procedures and standards. (a) General requirements. This section provides specifications for the test fuels required in...
Walker, C; Kaiser, K; Klein, W; Lagadic, L; Peakall, D; Sheffield, S; Soldan, T; Yasuno, M
1998-01-01
There is growing public pressure to minimize the use of vertebrates in ecotoxicity testing; therefore, effective alternatives to toxicity tests causing suffering are being sought. This report discusses alternatives and differs in some respects from the reports of the other three groups because the primary concern is with harmful effects of chemicals at the level of population and above rather than with harmful effects upon individuals. It is concluded that progress toward the objective of minimizing testing that causes suffering would be served by the following initiatives--a clearer definition of goals and strategies when undertaking testing procedures; development of alternative assays, including in vitro test systems, that are based on new technology; development of nondestructive assays for vertebrates (e.g., biomarkers) that do not cause suffering; selection of most appropriate species, strains, and developmental stages for testing procedures (but no additional species for basic testing); better integrated and more flexible testing procedures incorporating biomarker responses, ecophysiological concepts, and ecological end points (progress in this direction depends upon expert judgment). In general, testing procedures could be made more realistic, taking into account problems with mixtures, and with volatile or insoluble chemicals. PMID:9599690
40 CFR 85.2208 - Alternative standards and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... higher than the tests they would replace; (ii) Such procedures show a correlation with the Federal Test... higher than the tests they would replace; (ii) Such procedures show a correlation with the Federal Test...
Alternate Test Procedures to Perform Clean Water Act Monitoring for Region 9
When performing Clean Water Act monitoring, parties interested in using a method not approved in 40 CFR Part 136 must apply to use the alternate test procedure (ATP) in the Region in which the discharging facility is located.
Peterson, Jennifer R.; Hill, Catherine C.; Kirkpatrick, Kimberly
2016-01-01
Impulsive choice is typically measured by presenting smaller-sooner (SS) versus larger-later (LL) rewards, with biases towards the SS indicating impulsivity. The current study tested rats on different impulsive choice procedures with LL delay manipulations to assess same-form and alternate-form test-retest reliability. In the systematic-GE procedure (Green & Estle, 2003), the LL delay increased after several sessions of training; in the systematic-ER procedure (Evenden & Ryan, 1996), the delay increased within each session; and in the adjusting-M procedure (Mazur, 1987), the delay changed after each block of trials within a session based on each rat’s choices in the previous block. In addition to measuring choice behavior, we also assessed temporal tracking of the LL delays using the median times of responding during LL trials. The two systematic procedures yielded similar results in both choice and temporal tracking measures following extensive training, whereas the adjusting procedure resulted in relatively more impulsive choices and poorer temporal tracking. Overall, the three procedures produced acceptable same form test-retest reliability over time, but the adjusting procedure did not show significant alternate form test-retest reliability with the other two procedures. The results suggest that systematic procedures may supply better measurements of impulsive choice in rats. PMID:25490901
Alternatives to the sequential lineup: the importance of controlling the pictures.
Lindsay, R C; Bellinger, K
1999-06-01
Because sequential lineups reduce false-positive choices, their use has been recommended (R. C. L. Lindsay, 1999; R. C. L. Lindsay & G. L. Wells, 1985). Blind testing is included in the recommended procedures. Police, concerned about blind testing, devised alternative procedures, including self-administered sequential lineups, to reduce use of relative judgments (G. L. Wells, 1984) while permitting the investigating officer to conduct the procedure. Identification data from undergraduates exposed to a staged crime (N = 165) demonstrated that 4 alternative identification procedures tested were less effective than the original sequential lineup. Allowing witnesses to control the photographs resulted in higher rates of false-positive identification. Self-reports of using relative judgments were shown to be postdictive of decision accuracy.
Acute Oral Toxicity Up-And-Down-Procedure
The Up-and-Down Procedure is an alternative acute toxicity test that provides a way to determine the toxicity of chemicals with fewer test animals by using sequential dosing steps. Find out about this test procedure.
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... show that your engines comply with all applicable emission standards. (3) Any relevant factors...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... show that your engines comply with all applicable emission standards. (3) Any relevant factors...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... show that your engines comply with all applicable emission standards. (3) Any relevant factors...
ERIC Educational Resources Information Center
Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.
THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATING PRINCIPLES AND THE SERVICING AND TESTING PROCEDURES FOR ALTERNATING CURRENT (AC) GENERATORS AND REGULATORS USED ON DIESEL POWERED EQUIPMENT. TOPICS ARE REVIEW OF ALTERNATOR PRINCIPLES, ALTERNATOR SERVICING AND TESTING, ALTERNATOR REGULATOR OPERATING…
Unproven diagnostic procedures in IgE-mediated allergic diseases.
Niggemann, B; Grüber, C
2004-08-01
A considerable body of literature on therapeutic aspects of complementary and alternative medicine has been published in recent years, but little is known on diagnostic procedures. This short review lists complementary and alternative diagnostic procedures for the diagnosis of allergic diseases and presents an assessment of their usefulness for the daily practice. The review of the literature revealed that neither the determination of specific immunoglobulin G-antibodies in serum, the hair-analysis, the cytotoxic test, kinesiology, iridology, or electrodermal testing represent useful tests for the daily practice. To date, no complementary or alternative diagnostic procedure can be recommended as a meaningful element in the diagnostic work-up of allergic diseases. This is especially true for food allergy: properly performed oral food challenges still represent the gold standard for implementing specific diets in food allergic individuals. Ineffective diagnostic approaches may be costly for the consumer and delay appropriate therapy.
21 CFR 1010.13 - Special test procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Special test procedures. 1010.13 Section 1010.13 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR ELECTRONIC PRODUCTS: GENERAL Alternate Test Procedures § 1010.13...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2013 CFR
2013-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2010 CFR
2010-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2011 CFR
2011-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.
Code of Federal Regulations, 2012 CFR
2012-07-01
... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... Refrigerator-Freezer Test Procedures AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... from the DOE electric refrigerator and refrigerator-freezer test procedures for specific basic models set forth in its petition for waiver. In its petition, Samsung provides an alternate test procedure...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... Refrigerator-Freezer Test Procedures AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... from the DOE electric refrigerator and refrigerator-freezer test procedures for specific basic models set forth in its petition for waiver. In its petition, Samsung provides an alternate test procedure...
40 CFR 86.080-12 - Alternative certification procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.080-12 Alternative certification... are obtained under the abbreviated certification review procedure. (vii) Upon completing all... for certification, test reports and data submitted by the manufacturer, data obtained during an...
40 CFR 86.080-12 - Alternative certification procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.080-12 Alternative certification... are obtained under the abbreviated certification review procedure. (vii) Upon completing all... for certification, test reports and data submitted by the manufacturer, data obtained during an...
30 CFR 75.900-3 - Testing, examination, and maintenance of circuit breakers; procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... current circuits serving three-phase alternating current equipment and their auxiliary devices shall be... Underground Low- and Medium-Voltage Alternating Current Circuits § 75.900-3 Testing, examination, and...
30 CFR 75.900-3 - Testing, examination, and maintenance of circuit breakers; procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... current circuits serving three-phase alternating current equipment and their auxiliary devices shall be... Underground Low- and Medium-Voltage Alternating Current Circuits § 75.900-3 Testing, examination, and...
Test Operations Procedure (TOP) 01-2-624 High Power Microwave (HPM) Testing
2015-07-06
Requests _____ The proposed frequency list for the HPM facility is listed below. Source Primary Frequencies (MHz) Alternate Frequencies (MHz) NBTS...during testing. The proposed frequency list for the HPM facility is listed below. Source Primary Frequencies (MHz) Alternate Frequencies (MHz
40 CFR 136.5 - Approval of alternate test procedures for limited use.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS... may be made by letter, email or by hard copy. The application shall include the following: (1) Provide...
40 CFR 136.5 - Approval of alternate test procedures for limited use.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS... may be made by letter, email or by hard copy. The application shall include the following: (1) Provide...
40 CFR 136.5 - Approval of alternate test procedures for limited use.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS... may be made by letter, email or by hard copy. The application shall include the following: (1) Provide...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... procedure for determining the energy consumption of electric refrigerators and refrigerator-freezers. The... condensation. The existing test procedure does not take humidity or adaptive control technology into account. Therefore, Electrolux has suggested an alternate test procedure that takes adaptive control technology into...
40 CFR 136.4 - Application for and approval of alternate test procedures for nationwide use.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Procedure (ATP) Program Coordinator (National Coordinator), Office of Science and Technology (4303T), Office... or other categories. (4) Provide comparability data for the performance of the proposed alternative... information and data provided in the applicant's application. The Regional ATP Coordinator or permitting...
40 CFR 136.4 - Application for and approval of alternate test procedures for nationwide use.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Procedure (ATP) Program Coordinator (National Coordinator), Office of Science and Technology (4303T), Office... or other categories. (4) Provide comparability data for the performance of the proposed alternative... information and data provided in the applicant's application. The Regional ATP Coordinator or permitting...
40 CFR 136.4 - Application for and approval of alternate test procedures for nationwide use.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Procedure (ATP) Program Coordinator (National Coordinator), Office of Science and Technology (4303T), Office... or other categories. (4) Provide comparability data for the performance of the proposed alternative... information and data provided in the applicant's application. The Regional ATP Coordinator or permitting...
Statistical Cost Estimation in Higher Education: Some Alternatives.
ERIC Educational Resources Information Center
Brinkman, Paul T.; Niwa, Shelley
Recent developments in econometrics that are relevant to the task of estimating costs in higher education are reviewed. The relative effectiveness of alternative statistical procedures for estimating costs are also tested. Statistical cost estimation involves three basic parts: a model, a data set, and an estimation procedure. Actual data are used…
Procedures for Selecting Items for Computerized Adaptive Tests.
ERIC Educational Resources Information Center
Kingsbury, G. Gage; Zara, Anthony R.
1989-01-01
Several classical approaches and alternative approaches to item selection for computerized adaptive testing (CAT) are reviewed and compared. The study also describes procedures for constrained CAT that may be added to classical item selection approaches to allow them to be used for applied testing. (TJH)
40 CFR 86.162-03 - Approval of alternative air conditioning test simulations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conditioning test simulations. 86.162-03 Section 86.162-03 Protection of Environment ENVIRONMENTAL PROTECTION... Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.162-03 Approval of alternative air conditioning test simulations. (a) Upon petition from a manufacturer or upon the Agency's own...
de Wert, Guido; Liebaers, Inge; Van de Velde, Hilde
2007-09-01
There has been increasing support for combining preimplantation genetic diagnosis (PGD) for specific diseases with a test for human leukocyte antigens (HLA) because the generation of HLA-matched umbilical cord blood cells may save the life of a diseased sibling. To date, this procedure has taken place in the context of conceiving another child--PGD/HLA testing type 1. However, it may well become possible to perform PGD/HLA testing outside this context, that is, to select matched embryos from which embryonic stem cells could be derived and used in cell therapy--PGD/HLA testing type 2. A proactive ethical analysis is needed and is presented in this article. Although PGD/HLA testing type 1 can be morally justified, the risks, pitfalls, and practical limitations of this procedure make it necessary to develop alternative strategies. PGD/HLA testing type 2 may provide an alternative strategy. From an ethical point of view, the controversial issue is that this procedure creates embryos purely for instrumental use. However, given the dominant view that the preimplantation embryo has only limited moral value, this alternative may be as morally justified as PGD/HLA testing type 1.
40 CFR 1033.520 - Alternative ramped modal cycles.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Following the completion of the third test phase of the applicable ramped modal cycle, conduct the post... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.520 Alternative ramped modal... locomotive notch settings. Ramped modal cycles combine multiple test modes of a discrete-mode steady-state...
Slice-thickness evaluation in CT and MRI: an alternative computerised procedure.
Acri, G; Tripepi, M G; Causa, F; Testagrossa, B; Novario, R; Vermiglio, G
2012-04-01
The efficient use of computed tomography (CT) and magnetic resonance imaging (MRI) equipment necessitates establishing adequate quality-control (QC) procedures. In particular, the accuracy of slice thickness (ST) requires scan exploration of phantoms containing test objects (plane, cone or spiral). To simplify such procedures, a novel phantom and a computerised LabView-based procedure have been devised, enabling determination of full width at half maximum (FWHM) in real time. The phantom consists of a polymethyl methacrylate (PMMA) box, diagonally crossed by a PMMA septum dividing the box into two sections. The phantom images were acquired and processed using the LabView-based procedure. The LabView (LV) results were compared with those obtained by processing the same phantom images with commercial software, and the Fisher exact test (F test) was conducted on the resulting data sets to validate the proposed methodology. In all cases, there was no statistically significant variation between the two different procedures and the LV procedure, which can therefore be proposed as a valuable alternative to other commonly used procedures and be reliably used on any CT and MRI scanner.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-05
... Refrigeration Institute 1230 (AHRI) as the alternative test procedure. DATES: This Decision and Order is... testing procedures or rating procedures developed or recognized by the Air-Conditioning and Refrigeration... Refrigeration Institute (AHRI) Standard 1230-2010: Performance Rating of Variable Refrigerant Flow (VRF) Multi...
Permutation tests for goodness-of-fit testing of mathematical models to experimental data.
Fişek, M Hamit; Barlas, Zeynep
2013-03-01
This paper presents statistical procedures for improving the goodness-of-fit testing of theoretical models to data obtained from laboratory experiments. We use an experimental study in the expectation states research tradition which has been carried out in the "standardized experimental situation" associated with the program to illustrate the application of our procedures. We briefly review the expectation states research program and the fundamentals of resampling statistics as we develop our procedures in the resampling context. The first procedure we develop is a modification of the chi-square test which has been the primary statistical tool for assessing goodness of fit in the EST research program, but has problems associated with its use. We discuss these problems and suggest a procedure to overcome them. The second procedure we present, the "Average Absolute Deviation" test, is a new test and is proposed as an alternative to the chi square test, as being simpler and more informative. The third and fourth procedures are permutation versions of Jonckheere's test for ordered alternatives, and Kendall's tau(b), a rank order correlation coefficient. The fifth procedure is a new rank order goodness-of-fit test, which we call the "Deviation from Ideal Ranking" index, which we believe may be more useful than other rank order tests for assessing goodness-of-fit of models to experimental data. The application of these procedures to the sample data is illustrated in detail. We then present another laboratory study from an experimental paradigm different from the expectation states paradigm - the "network exchange" paradigm, and describe how our procedures may be applied to this data set. Copyright © 2012 Elsevier Inc. All rights reserved.
Simultaneous Versus Sequential Presentation in Testing Recognition Memory for Faces.
Finley, Jason R; Roediger, Henry L; Hughes, Andrea D; Wahlheim, Christopher N; Jacoby, Larry L
2015-01-01
Three experiments examined the issue of whether faces could be better recognized in a simul- taneous test format (2-alternative forced choice [2AFC]) or a sequential test format (yes-no). All experiments showed that when target faces were present in the test, the simultaneous procedure led to superior performance (area under the ROC curve), whether lures were high or low in similarity to the targets. However, when a target-absent condition was used in which no lures resembled the targets but the lures were similar to each other, the simultaneous procedure yielded higher false alarm rates (Experiments 2 and 3) and worse overall performance (Experi- ment 3). This pattern persisted even when we excluded responses that participants opted to withhold rather than volunteer. We conclude that for the basic recognition procedures used in these experiments, simultaneous presentation of alternatives (2AFC) generally leads to better discriminability than does sequential presentation (yes-no) when a target is among the alterna- tives. However, our results also show that the opposite can occur when there is no target among the alternatives. An important future step is to see whether these patterns extend to more realistic eyewitness lineup procedures. The pictures used in the experiment are available online at http://www.press.uillinois.edu/journals/ajp/media/testing_recognition/.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ACQUISITION PLANNING MARKET RESEARCH 410.002 Procedures. Market research must include obtaining information on the commercial quality assurance practices as an alternative for Government inspection and testing...
Code of Federal Regulations, 2013 CFR
2013-10-01
... ACQUISITION PLANNING MARKET RESEARCH 410.002 Procedures. Market research must include obtaining information on the commercial quality assurance practices as an alternative for Government inspection and testing...
Code of Federal Regulations, 2012 CFR
2012-10-01
... ACQUISITION PLANNING MARKET RESEARCH 410.002 Procedures. Market research must include obtaining information on the commercial quality assurance practices as an alternative for Government inspection and testing...
Identifying the bad guy in a lineup using confidence judgments under deadline pressure.
Brewer, Neil; Weber, Nathan; Wootton, David; Lindsay, D Stephen
2012-10-01
Eyewitness-identification tests often culminate in witnesses not picking the culprit or identifying innocent suspects. We tested a radical alternative to the traditional lineup procedure used in such tests. Rather than making a positive identification, witnesses made confidence judgments under a short deadline about whether each lineup member was the culprit. We compared this deadline procedure with the traditional sequential-lineup procedure in three experiments with retention intervals ranging from 5 min to 1 week. A classification algorithm that identified confidence criteria that optimally discriminated accurate from inaccurate decisions revealed that decision accuracy was 24% to 66% higher under the deadline procedure than under the traditional procedure. Confidence profiles across lineup stimuli were more informative than were identification decisions about the likelihood that an individual witness recognized the culprit or correctly recognized that the culprit was not present. Large differences between the maximum and the next-highest confidence value signaled very high accuracy. Future support for this procedure across varied conditions would highlight a viable alternative to the problematic lineup procedures that have traditionally been used by law enforcement.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-06
... Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act; Analysis and Sampling... for use as an alternative oil and grease method. Some comments were specific to the sampling...-side comparison using the specific procedures (e.g. sampling frequency, number of samples, QA/QC, and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-03
... condensing type direct heaters. In its petition, Empire provides an alternate test procedure, ANSI/ASHRAE... alternate procedure omits those sections of ANSI/ASHRAE 103-1993 that do not apply to condensing type direct heaters. DOE solicits comments, data, and information concerning Empire's petition and the suggested...
40 CFR 63.3151 - How do I demonstrate initial compliance with the emission limitations?
Code of Federal Regulations, 2010 CFR
2010-07-01
... matter and use that value as a substitute for mass fraction of organic HAP. (3) Alternative method. You may use an alternative test method for determining the mass fraction of organic HAP once the Administrator has approved it. You must follow the procedure in § 63.7(f) to submit an alternative test method...
Durability of hardboard siding
Anton TenWolde; Charles Carll
2004-01-01
In response to concerns about hardboard siding failures, a study was performed to assess if performance in a current hardboard industry quality assurance test procedure correlated with in-service performance and how well this performance might be predicted by use of alternative or additional test procedures. A variety of laboratory tests were performed on a large...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engine meets all applicable emission standards according to specified procedures. (iii) Use statistical.... (e) We may give you specific directions regarding methods for statistical analysis, or we may approve... statistical tests. Perform the tests as follows: (1) Repeat measurements for all applicable duty cycles at...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-24
...; Analysis and Sampling Procedures AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY... Contaminants Under the Safe Drinking Water Act; Analysis and Sampling Procedures. 75 FR 32295. June 8, 2010...
40 CFR 86.1773-99 - Test sequence; general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test simulation procedures, AC1 and AC2, for the 2001 to 2003 model years only. If a manufacturer desires to conduct an alternative SC03 test simulation other than AC1 and AC2, or the AC1 and AC2 simulations for the 2004 and subsequent model years, the simulation test procedure must be approved in advance...
40 CFR 86.1773-99 - Test sequence; general requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... test simulation procedures, AC1 and AC2, for the 2001 to 2003 model years only. If a manufacturer desires to conduct an alternative SC03 test simulation other than AC1 and AC2, or the AC1 and AC2 simulations for the 2004 and subsequent model years, the simulation test procedure must be approved in advance...
40 CFR 86.1773-99 - Test sequence; general requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... test simulation procedures, AC1 and AC2, for the 2001 to 2003 model years only. If a manufacturer desires to conduct an alternative SC03 test simulation other than AC1 and AC2, or the AC1 and AC2 simulations for the 2004 and subsequent model years, the simulation test procedure must be approved in advance...
ERIC Educational Resources Information Center
Livingston, Samuel A.; Chen, Haiwen H.
2015-01-01
Quantitative information about test score reliability can be presented in terms of the distribution of equated scores on an alternate form of the test for test takers with a given score on the form taken. In this paper, we describe a procedure for estimating that distribution, for any specified score on the test form taken, by estimating the joint…
Maine Educational Assessment (MEA) Operational Procedures, March 2005 Administration.
ERIC Educational Resources Information Center
Maine Department of Education, 2004
2004-01-01
This document is intended for use in conjunction with "Policies and Procedures for Accommodations and Alternate Assessment to the MEA," and both the "MEA Principal/Test Coordinator's Manual" and the "MEA Test Administrator's Manual." The first section, Enrollment, covers the following subjects: (1) Participation of Enrolled Students; (2) Students…
Associative Symmetry by Pigeons after Few-Exemplar Training
ERIC Educational Resources Information Center
Velasco, Saulo M.; Huziwara, Edson M.; Machado, Armando; Tomanari, Gerson Y.
2010-01-01
The present experiment investigated whether pigeons can show associative symmetry on a two-alternative matching-to-sample procedure. The procedure consisted of a within-subject sequence of training and testing with reinforcement, and it provided (a) exemplars of symmetrical responding, and (b) all prerequisite discriminations among test samples…
40 CFR 63.9816 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... with a catalytic oxidizer, records of annual checks of catalyst activity levels and subsequent... approved alternative monitoring method(s) or test procedure(s). (8) Records of maintenance activities and...
40 CFR 63.9816 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... with a catalytic oxidizer, records of annual checks of catalyst activity levels and subsequent... approved alternative monitoring method(s) or test procedure(s). (8) Records of maintenance activities and...
ERIC Educational Resources Information Center
Kim, Sooyeon; Livingston, Samuel A.
2017-01-01
The purpose of this simulation study was to assess the accuracy of a classical test theory (CTT)-based procedure for estimating the alternate-forms reliability of scores on a multistage test (MST) having 3 stages. We generated item difficulty and discrimination parameters for 10 parallel, nonoverlapping forms of the complete 3-stage test and…
Research and Development in Support of the Navy Technology Center for Safety and Survivability
1990-10-26
Patterson AFB, OH. W. E.; Naegeli , D. W.; Valtierra, M. L. An Alternate Test Proce-Black, B. H, M.S. Thesis, Southeastern Massachusetts University, dure to...Cuellar, Jr., J. P.; Dodge, L. G.; Likos, W. E.; Naegeli , D. W.; Valtierra, M. L. "An Alternative Test Procedure to Qualify Fuels for Navy Aircraft...Likos, W.E., Naegeli , D.W., Valtierra, M.L.; "An Alternative Test Proure to Qualify Fuels for Navy Aircraft," Final Report, Naval Air Propulsion Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Munk, Jeffrey D.; Shrestha, Som S.
The Oak Ridge National Laboratory (ORNL) High-Ambient Temperature Testing Program for Low-GWP Refrigerants aims to develop an understanding of the performance of low-Global Warming Potential (low-GWP) alternatives to Hydrochlorofluorocarbon (HCFC) and Hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high ambient temperature conditions. This interim working paper describes the parties involved, the alternative refrigerants selection process, the test procedures, and the preliminary results.
30 CFR 77.900-1 - Testing, examination, and maintenance of circuit breakers; procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... protecting low- and medium-voltage circuits serving portable or mobile three-phase alternating current... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits...
30 CFR 77.900-1 - Testing, examination, and maintenance of circuit breakers; procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... protecting low- and medium-voltage circuits serving portable or mobile three-phase alternating current... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits...
40 CFR 86.347-79 - Alternative calculations for diesel engines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Alternative calculations for diesel... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.347-79 Alternative calculations for diesel engines. (a) This section applies to Diesel...
40 CFR 86.347-79 - Alternative calculations for diesel engines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Alternative calculations for diesel... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.347-79 Alternative calculations for diesel engines. (a) This section applies to Diesel...
Validation of alternative methods for toxicity testing.
Bruner, L H; Carr, G J; Curren, R D; Chamberlain, M
1998-01-01
Before nonanimal toxicity tests may be officially accepted by regulatory agencies, it is generally agreed that the validity of the new methods must be demonstrated in an independent, scientifically sound validation program. Validation has been defined as the demonstration of the reliability and relevance of a test method for a particular purpose. This paper provides a brief review of the development of the theoretical aspects of the validation process and updates current thinking about objectively testing the performance of an alternative method in a validation study. Validation of alternative methods for eye irritation testing is a specific example illustrating important concepts. Although discussion focuses on the validation of alternative methods intended to replace current in vivo toxicity tests, the procedures can be used to assess the performance of alternative methods intended for other uses. Images Figure 1 PMID:9599695
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-06
... electric refrigerator and refrigerator-freezer test procedures for determining the energy consumption of... compressors using an alternate test procedure that takes this technology into account when measuring energy.... Bryan Berringer, U.S. Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-27
... electric refrigerator and refrigerator-freezer test procedures for determining the energy consumption of... using an alternate test procedure that takes this technology into account when measuring energy.... Bryan Berringer, U.S. Department of Energy, Building Technologies Program, Mail Stop EE-2J, Forrestal...
O'Connor, B P
2000-08-01
Popular statistical software packages do not have the proper procedures for determining the number of components in factor and principal components analyses. Parallel analysis and Velicer's minimum average partial (MAP) test are validated procedures, recommended widely by statisticians. However, many researchers continue to use alternative, simpler, but flawed procedures, such as the eigenvalues-greater-than-one rule. Use of the proper procedures might be increased if these procedures could be conducted within familiar software environments. This paper describes brief and efficient programs for using SPSS and SAS to conduct parallel analyses and the MAP test.
Statistical analysis of particle trajectories in living cells
NASA Astrophysics Data System (ADS)
Briane, Vincent; Kervrann, Charles; Vimond, Myriam
2018-06-01
Recent advances in molecular biology and fluorescence microscopy imaging have made possible the inference of the dynamics of molecules in living cells. Such inference allows us to understand and determine the organization and function of the cell. The trajectories of particles (e.g., biomolecules) in living cells, computed with the help of object tracking methods, can be modeled with diffusion processes. Three types of diffusion are considered: (i) free diffusion, (ii) subdiffusion, and (iii) superdiffusion. The mean-square displacement (MSD) is generally used to discriminate the three types of particle dynamics. We propose here a nonparametric three-decision test as an alternative to the MSD method. The rejection of the null hypothesis, i.e., free diffusion, is accompanied by claims of the direction of the alternative (subdiffusion or superdiffusion). We study the asymptotic behavior of the test statistic under the null hypothesis and under parametric alternatives which are currently considered in the biophysics literature. In addition, we adapt the multiple-testing procedure of Benjamini and Hochberg to fit with the three-decision-test setting, in order to apply the test procedure to a collection of independent trajectories. The performance of our procedure is much better than the MSD method as confirmed by Monte Carlo experiments. The method is demonstrated on real data sets corresponding to protein dynamics observed in fluorescence microscopy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... of average velocity during the run and using these data, in conjunction with the pre- and post-test..., you may choose to follow the post-test calibration procedures of Method 320 in appendix A to 40 CFR... of hazardous air pollutants during the press process. This test method requires a minimum of three...
Lieu, Dustin; Asatryan, Liana; Davies, Daryl L.
2016-01-01
Prior to testing novel therapeutics in humans, short and long term preclinical (i.e., animal), repetitive pharmacological and toxicological testing is required. In most cases, the preferred route of administration is via oral delivery. At the present time, oral delivery is mostly accomplished using an oral gavage procedure, in part, because it can achieve consistent and precise dosing in the animal model. Although this method is well established it does have complications that can result in a high rate of animal attrition. To this end, the procedure introduced here describes an alternative to the oral gavage method in which the desired drug is incorporated into a tastant, orally dissolving strip (ODS) that can simply be presented to the test animal where it is then rapidly taken up with minimal manipulation of the test subject. Herein, we demonstrate that preclinical, oral drug delivery using the ODS method represents a safe, convenient, and humane alternative to oral gavage. PMID:27078261
The presence-absence coliform test for monitoring drinking water quality.
Rice, E W; Geldreich, E E; Read, E J
1989-01-01
The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663
16 CFR 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
An extended sequential goodness-of-fit multiple testing method for discrete data.
Castro-Conde, Irene; Döhler, Sebastian; de Uña-Álvarez, Jacobo
2017-10-01
The sequential goodness-of-fit (SGoF) multiple testing method has recently been proposed as an alternative to the familywise error rate- and the false discovery rate-controlling procedures in high-dimensional problems. For discrete data, the SGoF method may be very conservative. In this paper, we introduce an alternative SGoF-type procedure that takes into account the discreteness of the test statistics. Like the original SGoF, our new method provides weak control of the false discovery rate/familywise error rate but attains false discovery rate levels closer to the desired nominal level, and thus it is more powerful. We study the performance of this method in a simulation study and illustrate its application to a real pharmacovigilance data set.
NASA Technical Reports Server (NTRS)
Rudy, D. H.; Morris, D. J.; Blanchard, D. K.; Cooke, C. H.; Rubin, S. G.
1975-01-01
The status of an investigation of four numerical techniques for the time-dependent compressible Navier-Stokes equations is presented. Results for free shear layer calculations in the Reynolds number range from 1000 to 81000 indicate that a sequential alternating-direction implicit (ADI) finite-difference procedure requires longer computing times to reach steady state than a low-storage hopscotch finite-difference procedure. A finite-element method with cubic approximating functions was found to require excessive computer storage and computation times. A fourth method, an alternating-direction cubic spline technique which is still being tested, is also described.
40 CFR 205.154 - Consideration of alternative test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycles § 205.154... test motorcycles which would not comply with the noise emission standards prescribed in § 205.152 when...
40 CFR 205.154 - Consideration of alternative test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycles § 205.154... test motorcycles which would not comply with the noise emission standards prescribed in § 205.152 when...
16 CFR § 1630.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 1-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
16 CFR § 1631.61 - Hide carpets and rugs-alternative washing procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... natural “lay” of the hair structure for ten complete strokes. (8) Place test specimen in a circulating... procedure under FF 2-70 for testing the flammability of shearling and hide rugs that (1) consist of natural wool or hair attached to the hide with no synthetic fibers and (2) have been treated with a fire...
... during the procedure. Considerations A skin or mucosal culture may be done along with this test. Other ... are examined by other tests or a viral culture. Alternative Names Skin lesion gram stain Images Viral ...
40 CFR 600.107-08 - Fuel specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Exhaust Emission Test Procedures § 600.107-08 Fuel specifications. (a) The test fuel specifications for... given in paragraph (b) of this section. (b)(1) Diesel test fuel used for cold temperature FTP testing... alternative fuel for cold temperature FTP testing. (c) Test fuels representing fuel types for which there are...
40 CFR 600.107-08 - Fuel specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Exhaust Emission Test Procedures § 600.107-08 Fuel specifications. (a) The test fuel specifications for... given in paragraph (b) of this section. (b)(1) Diesel test fuel used for cold temperature FTP testing... alternative fuel for cold temperature FTP testing. (c) Test fuels representing fuel types for which there are...
40 CFR 600.107-08 - Fuel specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Exhaust Emission Test Procedures § 600.107-08 Fuel specifications. (a) The test fuel specifications for... given in paragraph (b) of this section. (b)(1) Diesel test fuel used for cold temperature FTP testing... alternative fuel for cold temperature FTP testing. (c) Test fuels representing fuel types for which there are...
Nicholls, C; Karim, K; Piletsky, S; Saini, S; Setford, S
2006-01-15
The preparation of a molecularly imprinted polymer (MIP) for pentachlorophenol is described together with two alternative reporter derivatives for use in a displacement imprinted polymer receptor analysis (DIPRA) format procedure. In this procedure, alternative reporter molecules were rebound to the synthetic receptor sites and their displacement by the target analyte was employed as the basis of a simple procedure for the measurement of chlorophenols in water and packaging material samples. Water samples were extracted using the standard procedure (EPA 528) and a detection limit of 0.5 microg l(-1) was achieved using the DIPRA detection method, with good agreement between the displacement technique and GC-ECD analysis. A variety of packaging materials, extracted using a buffered detergent solution were also analysed using the DIPRA procedure and showed good agreement with GC results. In addition, investigation of the cross-reactivity of a range of pesticides and materials commonly encountered in environmental analysis indicated the procedure gave good discrimination between pesticides bearing a chlorophenolic moiety and other materials. The procedure is considered highly suitable for use as a rapid field-test method or for incorporation into a test kit device.
ERIC Educational Resources Information Center
Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.
THIS MODULE OF A 25-MODULE COURSE IS DESIGNED AS A REVIEW OF THE OPERATING PRINCIPLES AND SERVICING PROCEDURES FOR GENERATORS AND AS AN INTRODUCTION TO TRANSISTOR CONTROLLED VOLTAGE REGULATION FOR GENERATORS USED ON DIESEL POWERED EQUIPMENT. TOPICS ARE (1) REVIEW OF GENERATOR PRINCIPLES, AC AND DC, (2) SERVICING AND TESTING ALTERNATORS, AND (3)…
Marquez-Davila, G; Martinez-Barreda, C E
1985-01-01
Although still controversial, an etiologic role of Gardnerella vaginalis is imputed in vaginitis. Besides isolation of the organism by culture, two alternative diagnostic procedures have been claimed to be useful: the investigation of "clue cells" in clinical specimens and the amine volatilization test or fishy odor perception in genital secretions. Herein we report on the findings of the simultaneous use of G. vaginalis isolation, the clue cell test and amine volatilization perception in specimens from 1,263 consecutive female patients referred to our clinic. Our results show that the simultaneous use of both alternative tests is very useful as a screening procedure. A negative result of both tests predicts a negative culture result in 99% of the cases. However, a positive result of either or both should be considered as an indication to proceed to culture and not as diagnostic of infection. PMID:3878365
Radiated Susceptibility Test Procedure and Setup Exploiting Crosstalk
NASA Astrophysics Data System (ADS)
Grassi, F.; Pignari, S. A.; Spadacini, G.; Bisognin, P.; Pelissou, P.; Marra, S.
2016-05-01
In this work, basic principles of an alternative test procedure exploiting crosstalk to reproduce in the terminal loads of a wiring structure the same disturbances that would be induced by traditional radiated susceptibility (RS) tests are presented. Equivalence with radiation is achieved by the use of a generator circuit properly fed with two synchronized RF generators, and holds for whatever loads (even not linear) connected to the terminations of the cable harness. The proposed procedure is here tailored to the specific conditions of incidence foreseen by aerospace Standards on RS. Its effectiveness is validated by measurements carried out in an ad hoc test setup.
Testing 40 Predictions from the Transtheoretical Model Again, with Confidence
ERIC Educational Resources Information Center
Velicer, Wayne F.; Brick, Leslie Ann D.; Fava, Joseph L.; Prochaska, James O.
2013-01-01
Testing Theory-based Quantitative Predictions (TTQP) represents an alternative to traditional Null Hypothesis Significance Testing (NHST) procedures and is more appropriate for theory testing. The theory generates explicit effect size predictions and these effect size estimates, with related confidence intervals, are used to test the predictions.…
NASA Technical Reports Server (NTRS)
Colvin, E. L.; Emptage, M. R.
1992-01-01
The breaking load test provides quantitative stress corrosion cracking data by determining the residual strength of tension specimens that have been exposed to corrosive environments. Eight laboratories have participated in a cooperative test program under the auspices of ASTM Committee G-1 to evaluate the new test method. All eight laboratories were able to distinguish between three tempers of aluminum alloy 7075. The statistical analysis procedures that were used in the test program do not work well in all situations. An alternative procedure using Box-Cox transformations shows a great deal of promise. An ASTM standard method has been drafted which incorporates the Box-Cox procedure.
Suprono, Montry S; Kattadiyil, Mathew T; Goodacre, Charles J; Winer, Myron S
2012-10-01
Many new products have been introduced and marketed as alternatives to traditional irreversible hydrocolloid materials. These alternative materials have the same structural formula as addition reaction silicone, also known as vinyl polysiloxane (VPS), impression materials. Currently, there is limited in vitro and in vivo research on these products, including on the effects of chemical disinfectants on the materials. The purpose of this study was to compare the effects of a spray disinfecting technique on a traditional irreversible hydrocolloid and 3 new alternative impression materials in vitro. The tests were performed in accordance with the American National Standards Institute/American Dental Association (ANSI/ADA) Specification Nos. 18 and 19. Under standardized conditions, 100 impressions were made of a ruled test block with an irreversible hydrocolloid and 3 alternative impression materials. Nondisinfected irreversible hydrocolloid was used as the control. The impressions were examined for surface detail reproduction before and after disinfection with a chloramine-T product. Type III and Type V dental stone casts were evaluated for linear dimensional change and gypsum compatibility. Comparisons of linear dimensional change were analyzed with 2-way ANOVA of mean ranks with the Scheffé post hoc comparisons (α=.05). Data for surface detail reproduction were analyzed with the Wilcoxon Signed-Rank procedure and gypsum compatibility with the Kruskal-Wallis Rank procedure (α=.05). The alternative impression materials demonstrated significantly better outcomes with all 3 parameters tested. Disinfection with chloroamine-T did not have any effect on the 3 alternative impression materials. The irreversible hydrocolloid groups produced the most variability in the measurements of linear dimensional change. All of the tested materials were within the ADA's acceptable limit of 1.0% for linear dimensional change, except for the disinfected irreversible hydrocolloid impression material. The alternative impression materials performed best for the parameters tested. Spray disinfection had no effect on the alternative impression materials. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
The internal consistency of the standard gamble: tests after adjusting for prospect theory.
Oliver, Adam
2003-07-01
This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.
Uno, Hajime; Tian, Lu; Claggett, Brian; Wei, L J
2015-12-10
With censored event time observations, the logrank test is the most popular tool for testing the equality of two underlying survival distributions. Although this test is asymptotically distribution free, it may not be powerful when the proportional hazards assumption is violated. Various other novel testing procedures have been proposed, which generally are derived by assuming a class of specific alternative hypotheses with respect to the hazard functions. The test considered by Pepe and Fleming (1989) is based on a linear combination of weighted differences of the two Kaplan-Meier curves over time and is a natural tool to assess the difference of two survival functions directly. In this article, we take a similar approach but choose weights that are proportional to the observed standardized difference of the estimated survival curves at each time point. The new proposal automatically makes weighting adjustments empirically. The new test statistic is aimed at a one-sided general alternative hypothesis and is distributed with a short right tail under the null hypothesis but with a heavy tail under the alternative. The results from extensive numerical studies demonstrate that the new procedure performs well under various general alternatives with a caution of a minor inflation of the type I error rate when the sample size is small or the number of observed events is small. The survival data from a recent cancer comparative study are utilized for illustrating the implementation of the process. Copyright © 2015 John Wiley & Sons, Ltd.
40 CFR 86.1823-01 - Durability demonstration procedures for exhaust emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Discussion of the manufacturer's in-use verification procedures including testing performed, vehicle... performed should also be documented in the manufacturer's submission. The in-use verification program shall...), the Alternate Service Accumulation Durability Program described in § 86.094-13(e) or the Standard Self...
40 CFR 86.607-84 - Sample selection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Sample selection. 86.607-84 Section 86... selection. (a) Vehicles comprising a test sample which are required to be tested, pursuant to a test order... specified in the test order, an alternative selection procedure may be employed: Provided, That the...
40 CFR 86.347-79 - Alternative calculations for diesel engines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.347-79 Alternative calculations for diesel engines. (a) This section applies to Diesel engines only. Gasoline-fueled engines must use the calculations in § 86.345. (b) For Diesel engines, the...
40 CFR 86.347-79 - Alternative calculations for diesel engines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.347-79 Alternative calculations for diesel engines. (a) This section applies to Diesel engines only. Gasoline-fueled engines must use the calculations in § 86.345. (b) For Diesel engines, the...
Bayesian Methods for Determining the Importance of Effects
USDA-ARS?s Scientific Manuscript database
Criticisms have plagued the frequentist null-hypothesis significance testing (NHST) procedure since the day it was created from the Fisher Significance Test and Hypothesis Test of Jerzy Neyman and Egon Pearson. Alternatives to NHST exist in frequentist statistics, but competing methods are also avai...
Test Operations Procedure (TOP) 1-1-062 Environmental Effects Data Collection
2008-09-12
this procedure. 11. ESTIMATION DESCRIPTION The prime example of an empirically based model is the Universal Soil Loss Equation ( USLE ) developed...impacts to human health and welfare and to the natural environment. The type of data collected might include noise levels, soil erosion, and...uptake relevant to flora/fauna and the soil erosion effects of proposed testing. c. Plan to identify any modifications/alternatives implemented
A sup-score test for the cure fraction in mixture models for long-term survivors.
Hsu, Wei-Wen; Todem, David; Kim, KyungMann
2016-12-01
The evaluation of cure fractions in oncology research under the well known cure rate model has attracted considerable attention in the literature, but most of the existing testing procedures have relied on restrictive assumptions. A common assumption has been to restrict the cure fraction to a constant under alternatives to homogeneity, thereby neglecting any information from covariates. This article extends the literature by developing a score-based statistic that incorporates covariate information to detect cure fractions, with the existing testing procedure serving as a special case. A complication of this extension, however, is that the implied hypotheses are not typical and standard regularity conditions to conduct the test may not even hold. Using empirical processes arguments, we construct a sup-score test statistic for cure fractions and establish its limiting null distribution as a functional of mixtures of chi-square processes. In practice, we suggest a simple resampling procedure to approximate this limiting distribution. Our simulation results show that the proposed test can greatly improve efficiency over tests that neglect the heterogeneity of the cure fraction under the alternative. The practical utility of the methodology is illustrated using ovarian cancer survival data with long-term follow-up from the surveillance, epidemiology, and end results registry. © 2016, The International Biometric Society.
Reconnaissance On Chi-Square Test Procedure For Determining Two Species Association
NASA Astrophysics Data System (ADS)
Marisa, Hanifa
2008-01-01
Determining the assosiation of two species by using chi-square test has been published. Utility of this procedure to plants species at certain location, shows that the procedure could not find "ecologically" association. Tens sampling units have been made to record some weeds species in Indralaya, South Sumatera. Chi square test; Xt2 = N[|(ad)-(bc)|-(N/2)]2/mnrs (Eq:1) on two species (Cleome sp and Eleusine indica) of the weeds shows positive assosiation; while ecologically in nature, there is no relationship between them. Some alternatives are proposed to this problem; simplified chi-square test steps, make further study to find out ecologically association, or at last, ignore it.
Sweeney, Mary M.; Shahan, Timothy A.
2016-01-01
Resurgence following removal of alternative reinforcement has been studied in non-human animals, children with developmental disabilities, and typically functioning adults. Adult human laboratory studies have included responses without a controlled history of reinforcement, included only two response options, or involved extensive training. Arbitrary responses allow for control over history of reinforcement. Including an inactive response never associated with reinforcement allows the conclusion that resurgence exceeds extinction-induced variability. Although procedures with extensive training produce reliable resurgence, a brief procedure with the same experimental control would allow more efficient examination of resurgence in adult humans. We tested the acceptability of a brief, single-session, three-alternative forced-choice procedure as a model of resurgence in undergraduates. Selecting a shape was the target response (reinforced in Phase I), selecting another shape was the alternative response (reinforced in Phase II), and selecting a third shape was never reinforced. Despite manipulating number of trials and probability of reinforcement, resurgence of the target response did not consistently exceed increases in the inactive response. Our findings reiterate the importance of an inactive control response and call for reexamination of resurgence studies using only two response options. We discuss potential approaches to generate an acceptable, brief human laboratory resurgence procedure. PMID:26724752
Chen, Connie; Gribble, Matthew O; Bartroff, Jay; Bay, Steven M; Goldstein, Larry
2017-05-01
The United States's Clean Water Act stipulates in section 303(d) that states must identify impaired water bodies for which total maximum daily loads (TMDLs) of pollution inputs into water bodies are developed. Decision-making procedures about how to list, or delist, water bodies as impaired, or not, per Clean Water Act 303(d) differ across states. In states such as California, whether or not a particular monitoring sample suggests that water quality is impaired can be regarded as a binary outcome variable, and California's current regulatory framework invokes a version of the exact binomial test to consolidate evidence across samples and assess whether the overall water body complies with the Clean Water Act. Here, we contrast the performance of California's exact binomial test with one potential alternative, the Sequential Probability Ratio Test (SPRT). The SPRT uses a sequential testing framework, testing samples as they become available and evaluating evidence as it emerges, rather than measuring all the samples and calculating a test statistic at the end of the data collection process. Through simulations and theoretical derivations, we demonstrate that the SPRT on average requires fewer samples to be measured to have comparable Type I and Type II error rates as the current fixed-sample binomial test. Policymakers might consider efficient alternatives such as SPRT to current procedure. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fuel Economy Test Procedures and Labeling The U.S. Environmental Protection Agency (EPA) is responsible for motor vehicle fuel economy testing. Manufacturers test their own vehicles and report the . To aid consumers shopping for new vehicles, EPA redesigned the fuel economy window sticker posted on
40 CFR 87.89 - Compliance with smoke emission standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 87.89 Compliance with smoke emission standards... engine of the model being tested. An acceptable alternative to testing every engine is described in...
40 CFR 87.89 - Compliance with smoke emission standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 87.89 Compliance with smoke emission standards... engine of the model being tested. An acceptable alternative to testing every engine is described in...
Code of Federal Regulations, 2011 CFR
2011-01-01
... been washed and dried 50 times in machines, using the procedure specified in AATCC Test Method 124-1996... Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to... request of the Commission staff, any other information concerning the procedure and/or any machine used in...
Code of Federal Regulations, 2011 CFR
2011-01-01
... been washed and dried 50 times in machines, using the procedure specified in AATCC Test Method 124-1996... Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to... request of the Commission staff, any other information concerning the procedure and/or any machine used in...
Modeling Item-Position Effects within an IRT Framework
ERIC Educational Resources Information Center
Debeer, Dries; Janssen, Rianne
2013-01-01
Changing the order of items between alternate test forms to prevent copying and to enhance test security is a common practice in achievement testing. However, these changes in item order may affect item and test characteristics. Several procedures have been proposed for studying these item-order effects. The present study explores the use of…
40 CFR 80.176 - Alternative certification test procedures and standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... temperature. At the end of this 48-hour ambient temperature soak, an injector balance test is conducted to... injector balance test. (x) Fuel pressure gauge. A fuel pressure gauge capable of measuring fuel system... conducting the injector balance test. A pressure transducer shall not be used. (xi) Gaskets. The upper intake...
An Alternative Approach to Identifying a Dimension in Second Language Proficiency.
ERIC Educational Resources Information Center
Griffin, Patrick E.; And Others
Current practice in language testing has not yet integrated classical test theory with assessment of language skills. In addition, language testing needs to be part of theory development. Lack of sound testing procedures can lead to problems in research design and ultimately, inappropriate theory development. The debate over dimensionality of…
40 CFR 1033.520 - Alternative ramped modal cycles.
Code of Federal Regulations, 2014 CFR
2014-07-01
... warm it up. Then follow the provisions of 40 CFR part 1065, subpart F for general pre-test procedures (including engine and sampling system pre-conditioning). (d) Begin the test by operating the locomotive over the pre-test portion of the cycle. For locomotives not equipped with catalysts, you may begin the test...
40 CFR 1033.520 - Alternative ramped modal cycles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... warm it up. Then follow the provisions of 40 CFR part 1065, subpart F for general pre-test procedures (including engine and sampling system pre-conditioning). (d) Begin the test by operating the locomotive over the pre-test portion of the cycle. For locomotives not equipped with catalysts, you may begin the test...
40 CFR 1033.520 - Alternative ramped modal cycles.
Code of Federal Regulations, 2013 CFR
2013-07-01
... warm it up. Then follow the provisions of 40 CFR part 1065, subpart F for general pre-test procedures (including engine and sampling system pre-conditioning). (d) Begin the test by operating the locomotive over the pre-test portion of the cycle. For locomotives not equipped with catalysts, you may begin the test...
40 CFR 1033.520 - Alternative ramped modal cycles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... warm it up. Then follow the provisions of 40 CFR part 1065, subpart F for general pre-test procedures (including engine and sampling system pre-conditioning). (d) Begin the test by operating the locomotive over the pre-test portion of the cycle. For locomotives not equipped with catalysts, you may begin the test...
Sauerland, Melanie; Wolfs, Andrea C F; Crans, Samantha; Verschuere, Bruno
2017-11-27
Direct eyewitness identification is widely used, but prone to error. We tested the validity of indirect eyewitness identification decisions using the reaction time-based concealed information test (CIT) for assessing cooperative eyewitnesses' face memory as an alternative to traditional lineup procedures. In a series of five experiments, a total of 401 mock eyewitnesses watched one of 11 different stimulus events that depicted a breach of law. Eyewitness identifications in the CIT were derived from longer reaction times as compared to well-matched foil faces not encountered before. Across the five experiments, the weighted mean effect size d was 0.14 (95% CI 0.08-0.19). The reaction time-based CIT seems unsuited for testing cooperative eyewitnesses' memory for faces. The careful matching of the faces required for a fair lineup or the lack of intent to deceive may have hampered the diagnosticity of the reaction time-based CIT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Shrestha, Som S.; Munk, Jeffrey D.
The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for low– global warming potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerant selection process, the test procedures, and the final results.
DOT National Transportation Integrated Search
2015-04-01
To determine conformance with NHTSAs visual-manual interface distraction guidelines and to : reduce the associated number of crashes, NHTSA recommends a visual-occlusion test : procedure. As an alternative to testing subjects following that proced...
75 FR 11231 - Amendments to Regulation SHO
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-10
... procedures reasonably designed to impose this short sale price test restriction for the remainder of the day... security. In connection with this alternative, we proposed two short sale price tests. One was the modified... was designed to assist the Commission in assessing whether changes to short sale price test regulation...
Modeling and Assessment of Alternative Cooling Methods of the Combat Operation Center
2012-12-01
through the employment of a measure designed to remove heat load at a lower rate of power consumption than an ECU. 3. The Simulation To test the...24 G. PROCEDURE FOR TESTING PROPOSED SOLUTIONS .....................25 1. The Model...ASSUMPTIONS .............................................................................................28 1. July 2010 COC (v2) test
Special Problems and Procedures for Identifying Minority Gifted Students.
ERIC Educational Resources Information Center
Bernal, Ernest M.
The author reviews the key problems associated with generally accepted practices for identifying the gifted from the perspective of minority gifted students, particularly the gifted bilingual child; and presents some alternative approaches for testing. Noted among the shortcomings of testing minority students are that standardized tests are not…
40 CFR 86.157-98 - Refueling test procedures for liquefied petroleum gas-fueled vehicles.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., evaporative/refueling emission family, fuel tank(s) capacity, basic fuel system description and odometer.... As an alternative, a reference to a vehicle test cell number may be used, with advance approval of the Administrator, provided test cell calibration records show the pertinent instrument information...
Introducing Statistical Inference to Biology Students through Bootstrapping and Randomization
ERIC Educational Resources Information Center
Lock, Robin H.; Lock, Patti Frazer
2008-01-01
Bootstrap methods and randomization tests are increasingly being used as alternatives to standard statistical procedures in biology. They also serve as an effective introduction to the key ideas of statistical inference in introductory courses for biology students. We discuss the use of such simulation based procedures in an integrated curriculum…
Analysis of Slug Tests in Formations of High Hydraulic Conductivity
Butler, J.J.; Garnett, E.J.; Healey, J.M.
2003-01-01
A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.
Analysis of slug tests in formations of high hydraulic conductivity.
Butler, James J; Garnett, Elizabeth J; Healey, John M
2003-01-01
A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.
Cai, Li
2006-02-01
A permutation test typically requires fewer assumptions than does a comparable parametric counterpart. The multi-response permutation procedure (MRPP) is a class of multivariate permutation tests of group difference useful for the analysis of experimental data. However, psychologists seldom make use of the MRPP in data analysis, in part because the MRPP is not implemented in popular statistical packages that psychologists use. A set of SPSS macros implementing the MRPP test is provided in this article. The use of the macros is illustrated by analyzing example data sets.
ERIC Educational Resources Information Center
Ades, A. E.; Lu, Guobing; Dias, Sofia; Mayo-Wilson, Evan; Kounali, Daphne
2015-01-01
Objective: Trials often may report several similar outcomes measured on different test instruments. We explored a method for synthesising treatment effect information both within and between trials and for reporting treatment effects on a common scale as an alternative to standardisation Study design: We applied a procedure that simultaneously…
ERIC Educational Resources Information Center
Simen, Patrick; Contreras, David; Buck, Cara; Hu, Peter; Holmes, Philip; Cohen, Jonathan D.
2009-01-01
The drift-diffusion model (DDM) implements an optimal decision procedure for stationary, 2-alternative forced-choice tasks. The height of a decision threshold applied to accumulating information on each trial determines a speed-accuracy tradeoff (SAT) for the DDM, thereby accounting for a ubiquitous feature of human performance in speeded response…
77 FR 1129 - Revisions to Test Methods and Testing Regulations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-09
...This action proposes editorial and technical corrections necessary for source testing of emissions and operations. The revisions include the addition of alternative equipment and methods as well as corrections to technical and typographical errors. We also solicit public comment on potential changes to the current procedures for determining emission stratification.
An Alternative Methodology for Creating Parallel Test Forms Using the IRT Information Function.
ERIC Educational Resources Information Center
Ackerman, Terry A.
The purpose of this paper is to report results on the development of a new computer-assisted methodology for creating parallel test forms using the item response theory (IRT) information function. Recently, several researchers have approached test construction from a mathematical programming perspective. However, these procedures require…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-07
... systems. As a condition of this waiver, Daikin must use the alternate test procedure set forth in this... systems contain design characteristics that prevent them from being tested using the current DOE test.... The VRV-III-C systems have operational characteristics similar to other commercial multi-split...
46 CFR 160.151-57 - Servicing procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... weeks and be checked for leakage by weighing before being installed in a liferaft. An alternative... hydrostatic test under 49 CFR 180.205 must be tested and marked in accordance with that section. (f) At every... the servicing facility to maintain clearance during the test, a person weighing not less than 75 kg...
46 CFR 160.151-57 - Servicing procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... weeks and be checked for leakage by weighing before being installed in a liferaft. An alternative... hydrostatic test under 49 CFR 180.205 must be tested and marked in accordance with that section. (f) At every... the servicing facility to maintain clearance during the test, a person weighing not less than 75 kg...
46 CFR 160.151-57 - Servicing procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... weeks and be checked for leakage by weighing before being installed in a liferaft. An alternative... hydrostatic test under 49 CFR 180.205 must be tested and marked in accordance with that section. (f) At every... the servicing facility to maintain clearance during the test, a person weighing not less than 75 kg...
Deep Reconditioning Testing for near Earth Orbits
NASA Technical Reports Server (NTRS)
Betz, F. E.; Barnes, W. L.
1984-01-01
The problems and benefits of deep reconditioning to near Earth orbit missions with high cycle life and shallow discharge depth requirements is discussed. A simple battery level approach to deep reconditioning of nickel cadmium batteries in near Earth orbit is considered. A test plan was developed to perform deep reconditioning in direct comparison with an alternative trickle charge approach. The results demonstrate that the deep reconditioning procedure described for near Earth orbit application is inferior to the alternative of trickle charging.
NASA Technical Reports Server (NTRS)
Glasgow, S. D.; Kittredge, K. B.
2003-01-01
A thermal interface material is one of the many tools often used as part of the thermal control scheme for space-based applications. Historically, at Marshall Space Flight Center, CHO-THERM 1671 has primarily been used for applications where an interface material was deemed necessary. However, numerous alternatives have come on the market in recent years. It was decided that a number of these materials should be tested against each other to see if there were better performing alternatives. The tests were done strictly to compare the thermal performance of the materials relative to each other under repeatable conditions and do not take into consideration other design issues, such as off-gassing, electrical conduction, isolation, etc. The purpose of this Technical Memorandum is to detail the materials tested, test apparatus, procedures, and results of these tests. The results show that there are a number of better performing alternatives now available.
Gene Polymorphism Studies in a Teaching Laboratory
NASA Astrophysics Data System (ADS)
Shultz, Jeffry
2009-02-01
I present a laboratory procedure for illustrating transcription, post-transcriptional modification, gene conservation, and comparative genetics for use in undergraduate biology education. Students are individually assigned genes in a targeted biochemical pathway, for which they design and test polymerase chain reaction (PCR) primers. In this example, students used genes annotated for the steroid biosynthesis pathway in soybean. The authoritative Kyoto encyclopedia of genes and genomes (KEGG) interactive database and other online resources were used to design primers based first on soybean expressed sequence tags (ESTs), then on ESTs from an alternate organism if soybean sequence was unavailable. Students designed a total of 50 gene-based primer pairs (37 soybean, 13 alternative) and tested these for polymorphism state and similarity between two soybean and two pea lines. Student assessment was based on acquisition of laboratory skills and successful project completion. This simple procedure illustrates conservation of genes and is not limited to soybean or pea. Cost per student estimates are included, along with a detailed protocol and flow diagram of the procedure.
27 CFR 19.26 - Alternate methods or procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or... Provisions Alternate Methods Or Procedures and Experimental Operations § 19.26 Alternate methods or procedures. (a) General. The appropriate TTB officer may approve the use of an alternate method or procedure...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-31
...This action announces the U.S. Environmental Protection Agency's (EPA's) approval of alternative testing methods for use in measuring the levels of contaminants in drinking water and determining compliance with national primary drinking water regulations. The Safe Drinking Water Act (SDWA) authorizes EPA to approve the use of alternative testing methods through publication in the Federal Register. EPA is using this streamlined authority to make 84 additional methods available for analyzing drinking water samples. This expedited approach provides public water systems, laboratories, and primacy agencies with more timely access to new measurement techniques and greater flexibility in the selection of analytical methods, thereby reducing monitoring costs while maintaining public health protection.
DOT National Transportation Integrated Search
1982-01-01
Transportation Research Record 886 addresses "New Concepts in Data Analysis." The following papers are included within: "Origin-Destination Travel Survey for Southeast Michigan;" "Pilot Testing of Alternative Administrative Procedures and Survey Inst...
Go/No-Go Procedure with Compound Stimuli with Children with Autism
ERIC Educational Resources Information Center
Silva, Rafael Augusto; Debert, Paula
2017-01-01
The go/no-go with compound stimuli is an alternative to matching-to-sample to produce conditional and emergent relations in adults. The aim of this study was to evaluate the effectiveness of this procedure with two children diagnosed with autism. We trained and tested participants to respond to conditional relations among arbitrary stimuli using…
Development of Subscale Fast Cookoff Test (PREPRINT)
2006-09-21
The hazards classification procedures have been harmonized with both the UN Test and Criteria Manual for UN Series 1...aimed at the development of a sub-scale alternate test protocol to the external fire test currently required for final hazards classification (HC...external fire test currently required for final hazards classification (HC) of an ordnance system. The specific goal of this part of the task was
This Environmental Technology Verification Program test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR P...
Homogeneity tests of clustered diagnostic markers with applications to the BioCycle Study
Tang, Liansheng Larry; Liu, Aiyi; Schisterman, Enrique F.; Zhou, Xiao-Hua; Liu, Catherine Chun-ling
2014-01-01
Diagnostic trials often require the use of a homogeneity test among several markers. Such a test may be necessary to determine the power both during the design phase and in the initial analysis stage. However, no formal method is available for the power and sample size calculation when the number of markers is greater than two and marker measurements are clustered in subjects. This article presents two procedures for testing the accuracy among clustered diagnostic markers. The first procedure is a test of homogeneity among continuous markers based on a global null hypothesis of the same accuracy. The result under the alternative provides the explicit distribution for the power and sample size calculation. The second procedure is a simultaneous pairwise comparison test based on weighted areas under the receiver operating characteristic curves. This test is particularly useful if a global difference among markers is found by the homogeneity test. We apply our procedures to the BioCycle Study designed to assess and compare the accuracy of hormone and oxidative stress markers in distinguishing women with ovulatory menstrual cycles from those without. PMID:22733707
NASA Technical Reports Server (NTRS)
Stankovic, Ana V.
2003-01-01
Professor Stankovic will be developing and refining Simulink based models of the PM alternator and comparing the simulation results with experimental measurements taken from the unit. Her first task is to validate the models using the experimental data. Her next task is to develop alternative control techniques for the application of the Brayton Cycle PM Alternator in a nuclear electric propulsion vehicle. The control techniques will be first simulated using the validated models then tried experimentally with hardware available at NASA. Testing and simulation of a 2KW PM synchronous generator with diode bridge output is described. The parameters of a synchronous PM generator have been measured and used in simulation. Test procedures have been developed to verify the PM generator model with diode bridge output. Experimental and simulation results are in excellent agreement.
Code of Federal Regulations, 2014 CFR
2014-07-01
... native AOI concentration (ppm) of the effluent during stable conditions. (14) Post-test calibration. At... or removal efficiencies must be determined while etching a substrate (product, dummy, or test). For... curves for the subsequent destruction or removal efficiency tests. (8) Mass location calibration. A...
ERIC Educational Resources Information Center
Jan, Show-Li; Shieh, Gwowen
2017-01-01
Equivalence assessment is becoming an increasingly important topic in many application areas including behavioral and social sciences research. Although there exist more powerful tests, the two one-sided tests (TOST) procedure is a technically transparent and widely accepted method for establishing statistical equivalence. Alternatively, a direct…
Behavioral mechanisms of context fear generalization in mice
Huckleberry, Kylie A.; Ferguson, Laura B.
2016-01-01
There is growing interest in generalization of learned contextual fear, driven in part by the hypothesis that mood and anxiety disorders stem from impaired hippocampal mechanisms of fear generalization and discrimination. However, there has been relatively little investigation of the behavioral and procedural mechanisms that might control generalization of contextual fear. We assessed the relative contribution of different contextual features to context fear generalization and characterized how two common conditioning protocols—foreground (uncued) and background (cued) contextual fear conditioning—affected context fear generalization. In one experiment, mice were fear conditioned in context A, and then tested for contextual fear both in A and in an alternate context created by changing a subset of A's elements. The results suggest that floor configuration and odor are more salient features than chamber shape. A second experiment compared context fear generalization in background and foreground context conditioning. Although foreground conditioning produced more context fear than background conditioning, the two procedures produced equal amounts of generalized fear. Finally, results indicated that the order of context tests (original first versus alternate first) significantly modulates context fear generalization, perhaps because the original and alternate contexts are differentially sensitive to extinction. Overall, results demonstrate that context fear generalization is sensitive to procedural variations and likely reflects the operation of multiple interacting psychological and neural mechanisms. PMID:27918275
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-10
... petitioner, Electrolux's technology is similar to that used by General Electric Company (GE) and Whirlpool....S. Department of Energy (DOE) test procedure for determining the energy consumption of electric... humidity or adaptive control technology into account. Therefore, Electrolux has suggested an alternate test...
40 CFR 91.606 - Sample selection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Sample selection. 91.606 Section 91....606 Sample selection. (a) Engines comprising a test sample will be selected at the location and in the... in the manner specified in the test order, an alternative selection procedure may be employed...
40 CFR 90.507 - Sample selection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Sample selection. 90.507 Section 90... Auditing § 90.507 Sample selection. (a) Engines comprising a test sample will be selected at the location... cannot be selected in the manner specified in the test order, an alternative selection procedure may be...
40 CFR 89.507 - Sample selection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Sample selection. 89.507 Section 89... Auditing § 89.507 Sample selection. (a) Engines comprising a test sample will be selected at the location... cannot be selected in the manner specified in the test order, an alternative selection procedure may be...
Effectiveness of Field Trips in Teaching Groundwater Concepts.
ERIC Educational Resources Information Center
Pederson, Darryll T.
1979-01-01
The field trip procedures described were devised for use with freshman college students as an alternative to a classroom or laboratory session. Pre-test and post-test of students' knowledge of groundwater concepts show significant change in students' understanding of groundwater occurance and movement following such a trip. (RE)
40 CFR 86.308-79 - Gas specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.308-79... Diesel engine tests the diluent shall be zero-grade air. (3) Calibration or span gases for the NOX...) Alternate pure hydrogen fuel. Some HFID's are designed to operate on pure hydrogen. Generally the HFID fuel...
40 CFR 86.308-79 - Gas specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.308-79... Diesel engine tests the diluent shall be zero-grade air. (3) Calibration or span gases for the NOX...) Alternate pure hydrogen fuel. Some HFID's are designed to operate on pure hydrogen. Generally the HFID fuel...
Readability and Content Assessment of Informed Consent Forms for Medical Procedures in Croatia
Vučemilo, Luka; Borovečki, Ana
2015-01-01
Background High quality of informed consent form is essential for adequate information transfer between physicians and patients. Current status of medical procedure consent forms in clinical practice in Croatia specifically in terms of the readability and the content is unknown. The aim of this study was to assess the readability and the content of informed consent forms for diagnostic and therapeutic procedures used with patients in Croatia. Methods 52 informed consent forms from six Croatian hospitals on the secondary and tertiary health-care level were tested for reading difficulty using Simple Measure of Gobbledygook (SMOG) formula adjusted for Croatian language and for qualitative analysis of the content. Results The averaged SMOG grade of analyzed informed consent forms was 13.25 (SD 1.59, range 10–19). Content analysis revealed that informed consent forms included description of risks in 96% of the cases, benefits in 81%, description of procedures in 78%, alternatives in 52%, risks and benefits of alternatives in 17% and risks and benefits of not receiving treatment or undergoing procedures in 13%. Conclusions Readability of evaluated informed consent forms is not appropriate for the general population in Croatia. The content of the forms failed to include in high proportion of the cases description of alternatives, risks and benefits of alternatives, as well as risks and benefits of not receiving treatments or undergoing procedures. Data obtained from this research could help in development and improvement of informed consent forms in Croatia especially now when Croatian hospitals are undergoing the process of accreditation. PMID:26376183
NASA Technical Reports Server (NTRS)
Heard, Walter L., Jr.; Watson, Judith J.; Lake, Mark S.; Bush, Harold G.; Jensen, J. Kermit; Wallsom, Richard E.; Phelps, James E.
1992-01-01
Results are presented from a ground test program of an alternate mobile transporter (MT) concept and extravehicular activity (EVA) assembly procedure for the Space Station Freedom (SSF) truss keel. A three-bay orthogonal tetrahedral truss beam consisting of 44 2-in-diameter struts and 16 nodes was assembled repeatedly in neutral buoyancy by pairs of pressure-suited test subjects working from astronaut positioning devices (APD's) on the MT. The truss bays were cubic with edges 15 ft long. All the truss joint hardware was found to be EVA compatible. The average unit assembly time for a single pair of experienced test subjects was 27.6 sec/strut, which is about half the time derived from other SSF truss assembly tests. A concept for integration of utility trays during truss assembly is introduced and demonstrated in the assembly tests. The concept, which requires minimal EVA handling of the trays, is shown to have little impact on overall assembly time. The results of these tests indicate that by using an MT equipped with APD's, rapid EVA assembly of a space station-size truss structure can be expected.
Mass counts: ERP correlates of non-adjacent dependency learning under different exposure conditions.
Citron, Francesca M M; Oberecker, Regine; Friederici, Angela D; Mueller, Jutta L
2011-01-10
Miniature language learning can serve to model real language learning as high proficiency can be reached after very little exposure. In a previous study by Mueller et al. [18] German participants acquired non-adjacent syntactic dependencies by mere exposure to correct Italian sentences, but their ERP pattern differed from the one shown by native speakers. The present study follows up on that experiment using a similar design and material and is focused on two important issues: the influence of acoustic cues in the material and the impact of the learning procedure. With respect to the latter we compared alternating learning and test phases to a continuous learning and test phase. In addition, a splicing procedure eliminated prosodic cues in order to ensure that non-adjacent dependencies were learned instead of adjacent ones. Results for the continuous phase design showed a native-like biphasic ERP pattern, an N400 followed by a left-focused positivity. In the alternating design behavioural accuracy was lower and only an N400 was found. The results suggest an advantage of continuous learning phases for adult learners, possibly due to the absence of ungrammatical items present in the test phases in the alternating learning procedure. Furthermore, the replication of the earlier study with prosodically controlled material adds evidence to the general finding that syntactic non-adjacent dependencies can be learned from mere exposure to correct examples. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
27 CFR 27.221 - Alternate methods or procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or... Miscellaneous Provisions § 27.221 Alternate methods or procedures. (a) Application. An importer who desires to use an alternate method or procedure in lieu of a method or procedure prescribed by this part must...
27 CFR 17.3 - Alternate methods or procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or... PRODUCTS General Provisions § 17.3 Alternate methods or procedures. (a) General. The appropriate TTB officer may approve the use of an alternate method or procedure in lieu of a method or procedure...
Alternative Green Solvents Project
NASA Technical Reports Server (NTRS)
Maloney, Phillip R.
2012-01-01
Necessary for safe and proper functioning of equipment. Mainly halogenated solvents. Tetrachloride, Trichloroethylene (TCE), CFC-113. No longer used due to regulatory/safety concerns. Precision Cleaning at KSC: Small % of total parts. Used for liquid oxygen (LOX) systems. Dual solvent process. Vertrel MCA (decafluoropentane (DFP) and trons-dichloroethylene) HFE-7100. DFP has long term environmental concerns. Project Goals: a) Identify potential replacements. b) 22 wet chemical processes. c) 3 alternative processes. d) Develop test procedures. e) Contamination and cleaning. f) Analysis. g) Use results to recommend alternative processes. Conclusions: a) No alternative matched Vertrel in this study. b) No clear second place solvent. c) Hydrocarbons- easy; Fluorinated greases- difficult. d) Fluorinated component may be needed in replacement solvent. e) Process may need to make up for shortcoming of the solvent. f) Plasma and SCC02 warrant further testing.
ERIC Educational Resources Information Center
Ho, Tsung-Han
2010-01-01
Computerized adaptive testing (CAT) provides a highly efficient alternative to the paper-and-pencil test. By selecting items that match examinees' ability levels, CAT not only can shorten test length and administration time but it can also increase measurement precision and reduce measurement error. In CAT, maximum information (MI) is the most…
ERIC Educational Resources Information Center
Rheinheimer, David C.; Penfield, Douglas A.
The performance of analysis of covariance (ANCOVA) and six selected competitors was examined under varying experimental conditions through Monte Carlo simulations. The six alternatives were: (1) Quade's procedure (D. Quade, 1967); (2) Puri and Sen's solution (M. Puri and P. Sen, 1969); (3) Burnett and Barr's rank difference scores (T. Burnett and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Shrestha, Som S.; Shen, Bo
The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for Low-Global Warming Potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants relative to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in packaged or Rooftop Unit (RTU) air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerants selection process, the test procedures, and the final results.
Della-Torre, E; Berti, A; Yacoub, M R; Guglielmi, B; Tombetti, E; Sabbadini, M G; Voltolini, S; Colombo, G
2015-05-01
The purpose of the present work is to evaluate the efficacy of an approach that combines clinical history, skin tests results, and premedication, in preventing recurrent hypersensitivity reactions to iodinated contrast media (ICM). Skin Prick tests, Intradermal tests, and Patch tests were performed in 36 patients with a previous reaction to ICM. All patients underwent a second contrast enhanced radiological procedure with an alternative ICM selected on the basis of the proposed approach. After alternative ICM re-injection, only one patient presented a mild NIR. The proposed algorithm, validated in clinical settings where repeated radiological exams are needed, offers a safe and practical approach for protecting patients from recurrent hypersensitivity reactions to ICM.
Engineering calculations for communications satellite systems planning
NASA Technical Reports Server (NTRS)
Martin, C. H.; Gonsalvez, D. J.; Levis, C. A.; Wang, C. W.
1983-01-01
Progress is reported on a computer code to improve the efficiency of spectrum and orbit utilization for the Broadcasting Satellite Service in the 12 GHz band for Region 2. It implements a constrained gradient search procedure using an exponential objective function based on aggregate signal to noise ratio and an extended line search in the gradient direction. The procedure is tested against a manually generated initial scenario and appears to work satisfactorily. In this test it was assumed that alternate channels use orthogonal polarizations at any one satellite location.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-08
... Identification of Coliform Bacteria and Escherichia coli in Finished Waters, January 2007, Version 1.1... Membrane Filter Test Method for Detection and Identification of Coliform Bacteria and Escherichia coli in... Detection and Identification of Coliform Bacteria and Escherichia coli in Finished Waters. November, 2000...
Processes and Procedures for Estimating Score Reliability and Precision
ERIC Educational Resources Information Center
Bardhoshi, Gerta; Erford, Bradley T.
2017-01-01
Precision is a key facet of test development, with score reliability determined primarily according to the types of error one wants to approximate and demonstrate. This article identifies and discusses several primary forms of reliability estimation: internal consistency (i.e., split-half, KR-20, a), test-retest, alternate forms, interscorer, and…
Criterion-Related Validity: Assessing the Value of Subscores
ERIC Educational Resources Information Center
Davison, Mark L.; Davenport, Ernest C., Jr.; Chang, Yu-Feng; Vue, Kory; Su, Shiyang
2015-01-01
Criterion-related profile analysis (CPA) can be used to assess whether subscores of a test or test battery account for more criterion variance than does a single total score. Application of CPA to subscore evaluation is described, compared to alternative procedures, and illustrated using SAT data. Considerations other than validity and reliability…
16 CFR 1.20 - Alternative procedures.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Alternative procedures. 1.20 Section 1.20 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Rules and Rulemaking Under Section 18(a)(1)(B) of the FTC Act § 1.20 Alternative procedures. If...
Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A
NASA Technical Reports Server (NTRS)
Perez, Reinaldo J.
1990-01-01
A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.
Soil stabilization field trial : interim report I.
DOT National Transportation Integrated Search
2001-04-01
Shrinkage cracks in cement-stabilized bases/subbase can be alleviated by specifying the right cement dosage, or by other additives/procedures that suppress crack susceptibility. A field trial of six 1000 ft test sections to investigate several altern...
Soil stabilization field trial : interim report III.
DOT National Transportation Integrated Search
2003-11-01
Shrinkage cracks in cement-stabilized bases/subbase can be alleviated by specifying the right cement dosage, or by other additives/procedures that suppress crack susceptibility. A field trial of six 1000 ft test sections to investigate several altern...
Alternative to Nitric Acid Passivation Project Overview
NASA Technical Reports Server (NTRS)
Lewis, Pattie L.
2013-01-01
The standard practice for protection of stainless steel is a process called passivation. This procedure results in the formation of a metal oxide layer to prevent corrosion. Typical passivation procedures call for the use of nitric acid which exhibits excellent corrosion performance; however, there are a number of environmental, worker safety, and operational issues associated with its use. The longtime military specification for the passivation of stainless steel was cancelled in favor of newer specifications which allow for the use of citric acid in place of nitric acid. Citric acid offers a variety of benefits that include increased safety for personnel, reduced environmental impact, and reduced operational costs. There have been few studies, however, to determine whether citric acid is an acceptable alternative for NASA and DoD. This paper details activities to date including development of the joint test plan, on-going and planned testing, and preliminary results.
Increasing Efficiency of Fecal Coliform Testing Through EPA-Approved Alternate Method Colilert*-18
NASA Technical Reports Server (NTRS)
Cornwell, Brian
2017-01-01
The 21 SM 9221 E multiple-tube fermentation method for fecal coliform analysis requires a large time and reagent investment for the performing laboratory. In late 2010, the EPA approved an alternative procedure for the determination of fecal coliforms designated as Colilert*-18. However, as of late 2016, only two VELAP-certified laboratories in the Commonwealth of Virginia have been certified in this method.
Ramirez, Tzutzuy; Beken, Sonja; Chlebus, Magda; Ellis, Graham; Griesinger, Claudius; De Jonghe, Sandra; Manou, Irene; Mehling, Annette; Reisinger, Kerstin; Rossi, Laura H; van Benthem, Jan; van der Laan, Jan Willem; Weissenhorn, Renate; Sauer, Ursula G
2015-10-01
The European Partnership for Alternative Approaches to Animal Testing (EPAA) convened a workshop Knowledge sharing to facilitate regulatory decision-making. Fifty invited participants from the European Commission, national and European agencies and bodies, different industry sectors (chemicals, cosmetics, fragrances, pharmaceuticals, vaccines), and animal protection organizations attended the workshop. Four case studies exemplarily revealed which procedures are in place to obtain regulatory acceptance of new test methods in different sectors. Breakout groups discussed the status quo identifying the following facilitators for regulatory acceptance of alternatives to animal testing: Networking and communication (including cross-sector collaboration, international cooperation and harmonization); involvement of regulatory agencies from the initial stages of test method development on; certainty on prerequisites for test method acceptance including the establishment of specific criteria for regulatory acceptance. Data sharing and intellectual property issues affect many aspects of test method development, validation and regulatory acceptance. In principle, all activities should address replacement, reduction and refinement methods (albeit animal testing is generally prohibited in the cosmetics sector). Provision of financial resources and education support all activities aiming at facilitating the acceptance and use of alternatives to animal testing. Overall, workshop participants recommended building confidence in new methodologies by applying and gaining experience with them. Copyright © 2015 Elsevier Inc. All rights reserved.
Assessment of 25 kW free-piston Stirling technology alternatives for solar applications
NASA Technical Reports Server (NTRS)
Erbeznik, Raymond M.; White, Maurice A.; Penswick, L. B.; Neely, Ronald E.; Ritter, Darren C.; Wallace, David A.
1992-01-01
The final design, construction, and testing of a 25-kW free-piston advanced Stirling conversion system (ASCS) are examined. The final design of the free-piston hydraulic ASCS consists of five subsystems: heat transport subsystem (solar receiver and pool boiler), free-piston hydraulic Stirling engine, hydraulic subsystem, cooling subsystem, and electrical and control subsystem. Advantages and disadvantages are identified for each technology alternative. Technology alternatives considered are gas bearings vs flexure bearings, stationary magnet linear alternator vs moving magnetic linear alternator, and seven different control options. Component designs are generated using available in-house procedures to meet the requirements of the free-piston Stirling convertor configurations.
ERIC Educational Resources Information Center
Zimmerman, Donald W.
2012-01-01
In order to circumvent the influence of correlation in paired-samples and repeated measures experimental designs, researchers typically perform a one-sample Student "t" test on difference scores. That procedure entails some loss of power, because it employs N - 1 degrees of freedom instead of the 2N - 2 degrees of freedom of the…
Dumont, J.N.; Bantle, J.A.; Linder, G.; ,
2003-01-01
The energy crisis of the 1970's and 1980's prompted the search for alternative sources of fuel. With development of alternate sources of energy, concerns for biological resources potentially adversely impacted by these alternative technologies also heightened. For example, few biological tests were available at the time to study toxic effects of effluents on surface waters likely to serve as receiving streams for energy-production facilities; hence, we began to use Xenopus laevis embryos as test organisms to examine potential toxic effects associated with these effluents upon entering aquatic systems. As studies focused on potential adverse effects on aquatic systems continued, a test procedure was developed that led to the initial standardization of FETAX. Other .than a limited number of aquatic toxicity tests that used fathead minnows and cold-water fishes such as rainbow trout, X. laevis represented the only other aquatic vertebrate test system readily available to evaluate complex effluents. With numerous laboratories collaborating, the test with X. laevis was refined, improved, and developed as ASTM E-1439, Standard Guide for the Conducting Frog Embryo Teratogenesis Assay-Xenopus (FETAX). Collabrative work in the 1990s yielded procedural enhancements, for example, development of standard test solutions and exposure methods to handle volatile organics and hydrophobic compounds. As part of the ASTM process, a collaborative interlaboratory study was performed to determine the repeatability and reliability of FETAX. Parallel to these efforts, methods were also developed to test sediments and soils, and in situ test methods were developed to address "lab-to-field extrapolation errors" that could influence the method's use in ecological risk assessments. Additionally, a metabolic activation system composed of rat liver microsomes was developed which made FETAX more relevant to mammalian studies.
Alternatives to animal testing: A review.
Doke, Sonali K; Dhawale, Shashikant C
2015-07-01
The number of animals used in research has increased with the advancement of research and development in medical technology. Every year, millions of experimental animals are used all over the world. The pain, distress and death experienced by the animals during scientific experiments have been a debating issue for a long time. Besides the major concern of ethics, there are few more disadvantages of animal experimentation like requirement of skilled manpower, time consuming protocols and high cost. Various alternatives to animal testing were proposed to overcome the drawbacks associated with animal experiments and avoid the unethical procedures. A strategy of 3 Rs (i.e. reduction, refinement and replacement) is being applied for laboratory use of animals. Different methods and alternative organisms are applied to implement this strategy. These methods provide an alternative means for the drug and chemical testing, up to some levels. A brief account of these alternatives and advantages associated is discussed in this review with examples. An integrated application of these approaches would give an insight into minimum use of animals in scientific experiments.
Alternatives to animal testing: A review
Doke, Sonali K.; Dhawale, Shashikant C.
2013-01-01
The number of animals used in research has increased with the advancement of research and development in medical technology. Every year, millions of experimental animals are used all over the world. The pain, distress and death experienced by the animals during scientific experiments have been a debating issue for a long time. Besides the major concern of ethics, there are few more disadvantages of animal experimentation like requirement of skilled manpower, time consuming protocols and high cost. Various alternatives to animal testing were proposed to overcome the drawbacks associated with animal experiments and avoid the unethical procedures. A strategy of 3 Rs (i.e. reduction, refinement and replacement) is being applied for laboratory use of animals. Different methods and alternative organisms are applied to implement this strategy. These methods provide an alternative means for the drug and chemical testing, up to some levels. A brief account of these alternatives and advantages associated is discussed in this review with examples. An integrated application of these approaches would give an insight into minimum use of animals in scientific experiments. PMID:26106269
The Validity of Selection and Classification Procedures for Predicting Job Performance.
1987-04-01
lacholual or pulley Issues. They cemmunicate Me resulls of special analyses, Iantrim rp or phses of a teak, ad hasm quick macton werk. Paperm r reviw ...51 I. Alternative Selection Procedures ................. 56 J. Meta-Analyses of Validities ............. 58 K . Meta-Analytic Comparisons of...Aptitude Test Battery GM General Maintenance GS General Science GVN Cognitive Ability HS&T Health, Social and Technology K Motor Coordination KFM
Code of Federal Regulations, 2010 CFR
2010-07-01
... emissions limitations? (a) You must conduct each performance test that applies to your iron and steel...) Method 18 to determine the VOHAP concentration. Alternatively, you may use Method 25 to determine the... of total hydrocarbons (as hexane) for 180 continuous operating minutes. You must measure emissions at...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
... specific to the Carrier Super Modular Multi-System (SMMSi) variable refrigerant flow (VRF) multi-split... in this notice to test and rate its SMMSi VRF multi-split commercial heat pumps. DATES: This Decision... its SMMSi VRF multi-split products. Carrier must use the alternate test procedure provided in this...
Lillicrap, Adam; Belanger, Scott; Burden, Natalie; Du Pasquier, David; Embry, Michelle; Halder, Marlies; Lampi, Mark; Lee, Lucy; Norberg-King, Teresa J.; Rattner, Barnett A.; Schirmer, Kristin; Thomas, Paul
2016-01-01
The need for alternative approaches to the use of vertebrate animals for hazard assessment of chemicals and pollutants has become of increasing importance. It is now the first consideration when initiating a vertebrate ecotoxicity test, to ensure that unnecessary use of vertebrate organisms is minimized wherever possible. For some regulatory purposes, the use of vertebrate organisms for environmental risk assessments has been banned; in other situations, the number of organisms tested has been dramatically reduced or the severity of the procedure refined. However, there is still a long way to go to achieve a complete replacement of vertebrate organisms to generate environmental hazard data. The development of animal alternatives is based not just on ethical considerations but also on reducing the cost of performing vertebrate ecotoxicity tests and in some cases on providing better information aimed at improving environmental risk assessments. The present Focus article provides an overview of the considerable advances that have been made toward alternative approaches for ecotoxicity assessments over the last few decades.
Determination of Stress-Corrosion Cracking in Aluminum-Lithium Alloy ML377
NASA Technical Reports Server (NTRS)
Valek, Bryan C.
1995-01-01
The use of aluminum-lithium alloys for aerospace applications is currently being studied at NASA Langley Research Center's Metallic Materials Branch. The alloys in question will operate under stress in a corrosive environment. These conditions are ideal for the phenomena of Stress-Corrosion Cracking (SCC) to occur. The test procedure for SCC calls for alternate immersion and breaking load tests. These tests were optimized for the lab equipment and materials available in the Light Alloy lab. Al-Li alloy ML377 specimens were then subjected to alternate immersion and breaking load tests to determine residual strength and resistance to SCC. Corrosion morphology and microstructure were examined under magnification. Data shows that ML377 is highly resistant to stress-corrosion cracking.
Alternative approaches for vertebrate ecotoxicity tests in the ...
The need for alternative approaches to the use of vertebrate animals for hazard assessing chemicals and pollutants has become of increasing importance. It is now the first consideration when initiating a vertebrate ecotoxicity test, to ensure that unnecessary use of vertebrate organisms is minimised wherever possible. For some regulatory purposes, the use of vertebrate organisms for environmental risk assessments (ERA) has even been banned, and in other situations the numbers of organisms tested has been dramatically reduced, or the severity of the procedure refined. However, there is still a long way to go to achieve replacement of vertebrate organisms to generate environmental hazard data. The development of animal alternatives is not just based on ethical considerations but also to reduce the cost of performing vertebrate ecotoxicity tests and in some cases to provide better information aimed at improving ERAs. The present focus paper provides an overview of the considerable advances that have been made towards alternative approaches for ecotoxicity assessments over the last few decades. The need for alternative approaches to the use of vertebrate animals for hazard assessing chemicals and pollutants has become of increasing importance. It is now the first consideration when initiating a vertebrate ecotoxicity test, to ensure that unnecessary use of vertebrate organisms is minimised wherever possible. For some regulatory purposes, the use of vertebrate organi
27 CFR 19.665 - Alternate methods or procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or... General § 19.665 Alternate methods or procedures. (a) General. The appropriate TTB officer may approve the use of an alternate method or procedure that varies from the regulatory requirements in this subpart...
27 CFR 18.13 - Alternate methods or procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or... and Miscellaneous Provisions § 18.13 Alternate methods or procedures. (a) General. The proprietor, on specific approval by the appropriate TTB officer, may use an alternate method or procedure in lieu of a...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-26
... Committee 221: Aircraft Secondary Barriers and Alternative Flight Deck Security Procedures AGENCY: Federal... Secondary Barriers and Alternative Flight Deck Security Procedures. SUMMARY: The FAA is issuing this notice... Alternative Flight Deck Security Procedures. DATES: The meeting will be held September 14-15, 2010. September...
Gas-injection-start and shutdown characteristics of a 2-kilowatt to 15-kilowatt Brayton power system
NASA Technical Reports Server (NTRS)
Cantoni, D. A.
1972-01-01
Two methods of starting the Brayton power system have been considered: (1) using the alternator as a motor to spin the Brayton rotating unit (BRU), and (2) spinning the BRU by forced gas injection. The first method requires the use of an auxiliary electrical power source. An alternating voltage is applied to the terminals of the alternator to drive it as an induction motor. Only gas-injection starts are discussed in this report. The gas-injection starting method requires high-pressure gas storage and valves to route the gas flow to provide correct BRU rotation. An analog computer simulation was used to size hardware and to determine safe start and shutdown procedures. The simulation was also used to define the range of conditions for successful startups. Experimental data were also obtained under various test conditions. These data verify the validity of the start and shutdown procedures.
29 CFR 102.93 - Alternative procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 2 2010-07-01 2010-07-01 false Alternative procedure. 102.93 Section 102.93 Labor Regulations Relating to Labor NATIONAL LABOR RELATIONS BOARD RULES AND REGULATIONS, SERIES 8 Procedure To Hear and Determine Disputes Under Section 10(k) of the Act § 102.93 Alternative procedure. If, either...
10 CFR 1040.89-12 - Alternate funds disbursal procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Alternate funds disbursal procedure. 1040.89-12 Section... Investigation, Conciliation and Enforcement Procedures § 1040.89-12 Alternate funds disbursal procedure. (a) When DOE withholds funds from a recipient under these regulations, the Secretary or designee may...
Jeffries, Marlo K Sellin; Stultz, Amy E; Smith, Austin W; Rawlings, Jane M; Belanger, Scott E; Oris, James T
2014-11-01
An increased demand for chemical toxicity evaluations has resulted in the need for alternative testing strategies that address animal welfare concerns. The fish embryo toxicity (FET) test developed for zebrafish (Danio rerio) is one such alternative, and the application of the FET test to other species such as the fathead minnow (Pimephales promelas) has been proposed. In the present study, the performances of the FET test and the larval growth and survival (LGS; a standard toxicity testing method) test in zebrafish and fathead minnows were evaluated. This required that testing methods for the fathead minnow FET and zebrafish LGS tests be harmonized with existing test methods and that the performance of these testing strategies be evaluated by comparing the median lethal concentrations of 2 reference toxicants, 3,4-dicholoraniline and ammonia, obtained via each of the test types. The results showed that procedures for the zebrafish FET test can be adapted and applied to the fathead minnow. Differences in test sensitivity were observed for 3,4-dicholoraniline but not ammonia; therefore, conclusions regarding which test types offer the least or most sensitivity could not be made. Overall, these results show that the fathead minnow FET test has potential as an alternative toxicity testing strategy and that further analysis with other toxicants is warranted in an effort to better characterize the sensitivity and feasibility of this testing strategy. © 2014 SETAC.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-25
... anti-sweat heaters. Therefore, it is ordered that: The application for interim waiver filed by Samsung... control anti-sweat heaters according to the alternate test procedure as set forth in section IV...
Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design.
Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana
2015-12-01
During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure-physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.
Weiner, M; Penha, P D
1990-01-01
An investigation of the hydrolysis of Tween 80 reagent by Branhamella catarrhalis and related organisms (Neisseria and Moraxella species) revealed that only B. catarrhalis gave a positive result. A total of 226 strains, including reference organisms and clinical isolates, were studied. B. catarrhalis changed the color of the reagent from amber to pink-red after overnight incubation. We recommend this simple and cost-effective test as an alternative procedure to DNase testing or tributyrin hydrolysis or as a supplemental procedure for the identification of B. catarrhalis in clinical specimens. PMID:2105335
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, V.E.
1982-01-01
A class of goodness-of-fit estimators is found to provide a useful alternative in certain situations to the standard maximum likelihood method which has some undesirable estimation characteristics for estimation from the three-parameter lognormal distribution. The class of goodness-of-fit tests considered include the Shapiro-Wilk and Filliben tests which reduce to a weighted linear combination of the order statistics that can be maximized in estimation problems. The weighted order statistic estimators are compared to the standard procedures in Monte Carlo simulations. Robustness of the procedures are examined and example data sets analyzed.
Adamska, K; Bellinghausen, R; Voelkel, A
2008-06-27
The Hansen solubility parameter (HSP) seems to be a useful tool for the thermodynamic characterization of different materials. Unfortunately, estimation of the HSP values can cause some problems. In this work different procedures by using inverse gas chromatography have been presented for calculation of pharmaceutical excipients' solubility parameter. The new procedure proposed, based on the Lindvig et al. methodology, where experimental data of Flory-Huggins interaction parameter are used, can be a reasonable alternative for the estimation of HSP values. The advantage of this method is that the values of Flory-Huggins interaction parameter chi for all test solutes are used for further calculation, thus diverse interactions between test solute and material are taken into consideration.
27 CFR 24.22 - Alternate method or procedure.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate method or... § 24.22 Alternate method or procedure. (a) General. The proprietor, on specific approval of the appropriate TTB officer as provided in this section, may use an alternate method or procedure in lieu of a...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-26
... 221: Aircraft Secondary Barriers and Alternative Flight Deck Security Procedures AGENCY: Federal... Secondary Barriers and Alternative Flight Deck Security Procedures. SUMMARY: The FAA is issuing this notice... Alternative Flight Deck Security Procedures. DATES: The meeting will be held March 16-17, 2010. March 16th...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
... 221: Aircraft Secondary Barriers and Alternative Flight Deck Security Procedures AGENCY: Federal... Secondary Barriers and Alternative Flight Deck Security Procedures. SUMMARY: The FAA is issuing this notice... Alternative Flight Deck Security Procedures. DATES: The meeting will be held July 19-20, from 9:00 a.m. to 5...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-20
... 221: Aircraft Secondary Barriers and Alternative Flight Deck Security Procedures AGENCY: Federal... Secondary Barriers and Alternative Flight Deck Security Procedures. SUMMARY: The FAA is issuing this notice... Alternative Flight Deck Security Procedures. DATES: The meeting will be held May 10-11, 2011, from 9 a.m. to 5...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-27
... 221: Aircraft Secondary Barriers and Alternative Flight Deck Security Procedures. AGENCY: Federal... Secondary Barriers and Alternative Flight Deck Security Procedures. SUMMARY: The FAA is issuing this notice... Alternative Flight Deck Security Procedures. DATES: The meeting will be held June 15-16, 2010. June 15th from...
Lee, Miri; Hwang, Jee-Hyun; Lim, Kyung-Min
2017-01-01
Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 404 and OECD TG 405 but it has been criticized with respect to animal welfare due to invasive and cruel procedure. To replace it, diverse alternatives have been developed: (i) For Draize eye irritation test, organotypic assay, in vitro cytotoxicity-based method, in chemico tests, in silico prediction model, and 3D reconstructed human cornea-like epithelium (RhCE); (ii) For Draize skin irritation test, in vitro cytotoxicity-based cell model, and 3D reconstructed human epidermis models (RhE). Of these, RhCE and RhE models are getting spotlight as a promising alternative with a wide applicability domain covering cosmetics and personal care products. In this review, we overviewed the current alternatives to Draize test with a focus on 3D human epithelium models to provide an insight into advancing and widening their utility. PMID:28744350
The botulinum neurotoxin LD50 test - problems and solutions.
Bitz, Silke
2010-01-01
Apart from the fact that the LD50 test is generally considered a procedure causing severe distress, which alone should result in its immediate deletion, it also conflicts with the EU wide ban on cosmetic testing in animals in the case of Botulinum Neurotoxin (BoNT) testing. The European Pharmacopoeia monograph allows for the use of three alternative methods provided they are validated. However these alternative assays are neither implemented by the manufactures of BoNT products nor are they enforced by the responsible authorities, e.g. by deleting the LD50 from the European Pharmacopoeia. The number of animals used for the testing of BoNT is not officially recorded. However, data from an undercover investigation allow the estimation that the number of mice used in LD50tests for BoNT products is greater than 600,000 per year worldwide.
Code of Federal Regulations, 2014 CFR
2014-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2010 CFR
2010-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2013 CFR
2013-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2011 CFR
2011-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Validation of Modifications to the ANSR(®) Listeria Method for Improved Ease of Use and Performance.
Caballero, Oscar; Alles, Susan; Le, Quynh-Nhi; Gray, R Lucas; Hosking, Edan; Pinkava, Lisa; Norton, Paul; Tolan, Jerry; Mozola, Mark; Rice, Jennifer; Chen, Yi; Odumeru, Joseph; Ryser, Elliot
2016-01-01
A study was conducted to validate minor reagent formulation, enrichment, and procedural changes to the ANSR(®) Listeria method, Performance-Tested Method(SM) 101202. In order to improve ease of use and diminish risk of amplicon contamination, the lyophilized reagent components were reformulated for increased solubility, thus eliminating the need to mix by pipetting. In the alternative procedure, an aliquot of the lysate is added to lyophilized ANSR reagents, immediately capped, and briefly mixed by vortexing. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were seen with hot dogs and Mexican-style cheese after 16 h enrichment, with the reference methods producing more positive results. After 24 h enrichment, however, there were no significant differences in method performance for any of the four matrixes tested. Robustness testing was also conducted, with variations to lysis buffer volume, lysis time, and sample volume having no demonstrable effect on assay results. Accelerated stability testing was carried out over a 10-week period and showed no diminishment in assay performance. A second phase of the study examined performance of the ANSR assay following enrichment in a new medium, LESS Plus broth, designed for use with all food and environmental sample types. With the alternative LESS Plus broth, there were no significant differences in performance between the ANSR method and the reference culture procedures for any of the matrixes tested after either 16 or 24 h enrichment, although 24 h enrichment is recommended for hot dogs due to higher sensitivity. Results of inclusivity and exclusivity testing using LESS Plus broth showed that the ANSR assay is highly specific, with 100% expected results for target and nontarget bacteria.
Leenaars, P P; Hendriksen, C F; de Leeuw, W A; Carat, F; Delahaut, P; Fischer, R; Halder, M; Hanly, W C; Hartinger, J; Hau, J; Lindblad, E B; Nicklas, W; Outschoorn, I M; Stewart-Tull, D E
1999-01-01
This is the report of the thirty-fifth of a series of workshops organised by the European Centre for the Validation of Alternative Methods (ECVAM). ECVAM's main goal, as defined in 1993 by its Scientific Advisory Committee, is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine or replace the use of laboratory animals. One of the first priorities set by ECVAM was the implementation of procedures which would enable it to become well informed about the state-of-the-art of non-animal test development and validation, and the potential for the possible incorporation of alternative tests into regulatory procedures. It was decided that this would be best achieved by the organisation of ECVAM workshops on specific topics, at which small groups of invited experts would review the current status of various types of in vitro tests and their potential uses, and make recommendations about the best ways forward (1). This joint ECVAM/FELASA (Federation of European Laboratory Animal Science Associations) workshop on The Immunisation of Laboratory Animals for the Production of Polyclonal Antibodies was held in Utrecht (The Netherlands), on 20-22 March 1998, under the co-chairmanship of Coenraad Hendriksen (RIVM, Bilthoven, The Netherlands) and Wim de Leeuw (Inspectorate for Health Protection, The Netherlands). The participants, all experts in the fields of immunology, laboratory animal science, or regulation, came from universities, industry and regulatory bodies. The aims of the workshop were: a) to discuss and evaluate current immunisation procedures for the production of polyclonal antibodies (including route of injection, animal species and adjuvant ); and b) to draft recommendations and guidelines to improve the immunisation procedures, with regard both to animal welfare and to the optimisation of immunisation protocols. This report summarises the outcome of the discussions and includes a number of recommendations and a set of draft guidelines (included in Appendix 1). 1999 FRAME.
Barnes Maze Procedure for Spatial Learning and Memory in Mice.
Pitts, Matthew W
2018-03-05
The Barnes maze is a dry-land based rodent behavioral paradigm for assessing spatial learning and memory that was originally developed by its namesake, Carol Barnes. It represents a well-established alternative to the more popular Morris Water maze and offers the advantage of being free from the potentially confounding influence of swimming behavior. Herein, the Barnes maze experimental setup and corresponding procedures for testing and analysis in mice are described in detail.
Design and Field Testing of a Systematic Procedure for Evaluating Vocational Programs. Final Report.
ERIC Educational Resources Information Center
Portland Public Schools, OR.
The purpose of a project was to design and field-test a system for evaluating the adequacy of the vocational curriculum utilized by the Vocational Village, an alternative school for the training of individuals who have experienced failure in other educational settings. Focus was on the development of an evaluation model which will assess the…
ERIC Educational Resources Information Center
Liao, Chi-Wen; Livingston, Samuel A.
2008-01-01
Randomly equivalent forms (REF) of tests in listening and reading for nonnative speakers of English were created by stratified random assignment of items to forms, stratifying on item content and predicted difficulty. The study included 50 replications of the procedure for each test. Each replication generated 2 REFs. The equivalence of those 2…
ERIC Educational Resources Information Center
Frederickson, Edward W.; And Others
The development and evaluation of prototype hands-on equipment, job sample performance tests for a high skilled technical Military Occupational Specialty (MOS) are described. An electronic maintenance MOS (26C20) was used as the research vehicle. The results led to the conclusion that valid and reliable performance tests could be constructed, but…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-17
... decision and order must be used for all future testing for any basic models covered by the decision and... require petitioners to: (1) Specify the basic model(s) to which the waiver applies; (2) identify other manufacturers of similar products; (3) include any known alternate test procedures of the basic model, with the...
Exact intervals and tests for median when one sample value possibly an outliner
NASA Technical Reports Server (NTRS)
Keller, G. J.; Walsh, J. E.
1973-01-01
Available are independent observations (continuous data) that are believed to be a random sample. Desired are distribution-free confidence intervals and significance tests for the population median. However, there is the possibility that either the smallest or the largest observation is an outlier. Then, use of a procedure for rejection of an outlying observation might seem appropriate. Such a procedure would consider that two alternative situations are possible and would select one of them. Either (1) the n observations are truly a random sample, or (2) an outlier exists and its removal leaves a random sample of size n-1. For either situation, confidence intervals and tests are desired for the median of the population yielding the random sample. Unfortunately, satisfactory rejection procedures of a distribution-free nature do not seem to be available. Moreover, all rejection procedures impose undesirable conditional effects on the observations, and also, can select the wrong one of the two above situations. It is found that two-sided intervals and tests based on two symmetrically located order statistics (not the largest and smallest) of the n observations have this property.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-01
... anti-sweat heaters. Therefore, it is ordered that: The application for interim waiver filed by Samsung... control anti-sweat heaters according to the alternate test procedure as set forth in section IV...
75 FR 2591 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-15
... on vital microprocessor-based systems. CSXT proposes to verify and test signal locking systems controlled by microprocessor-based equipment by use of alternative procedures every 4 years after initial... vital microprocessor-based systems. These systems utilize programmed logic equations in lieu of relays...
Warm-Up Effect in Panelist-Articulated-2-Alternative Forced Choice Test.
Bloom, David J; Baik, Hwa-Young; Lee, Soo-Yeun
2018-01-01
Panelist performance in discrimination tests has been shown to increase when warm-up samples are provided prior to the actual test. Samples are used prior to the actual test for the attribute articulation process of a panelist-articulated-2-alternative forced choice (PA-2-AFC) procedure; however, it is yet unknown if the pretest articulation phase adds to the power of this testing method as with the warm-up. The goal of the study was to determine if a "warm-up" effect was displayed in the PA-2-AFC test resulting in greater power compared to the researcher-designated-2-AFC (RD-2-AFC) test. A RD-2-AFC test, with and without warm-up samples, and a PA-2-AFC test were performed by 61 panelists. A reduced calorie, citrus-flavored, and carbonated beverage was used in the tests. During RD-2-AFC testing, panelists were asked to identify which sample was more sour. For PA-2-AFC testing, panelists individually articulated the nature and direction of the difference between the 2 samples through a pretesting articulation procedure. The articulated difference was, then, used in standard 2-AFC test procedure. A warm-up effect was observed when comparing the standard RD-2-AFC with and without warm-up samples. The addition of warm up samples significantly increased the power of the test, in addition, the PA-2-AFC method had lower power than the RD-2-AFC method. The increase in power with the addition of warm-up samples for the RD-2-AFC procedure supports literature findings on the benefit of providing warm-up samples. No warm-up effect can be attributed to the PA-2-AFC method evidenced by the overall low power observed, which may be attributed to sample complexity. Selecting a specified discrimination testing method is advantageous and can reduce costs of sensory testing, but has been considered unpractical when samples may differ in unknown ways. This research explores the use of panelist derived terms to circumvent the need for researchers to identify these differences and compares the results to using research designated terms in discrimination testing. Results from this study can be utilized in creating ways to incorporate more powerful methods into sensory discrimination testing plans and provides researchers with a means for selecting terms for use in specified discrimination testing methods. © 2017 Institute of Food Technologists®.
Classical Testing in Functional Linear Models.
Kong, Dehan; Staicu, Ana-Maria; Maity, Arnab
2016-01-01
We extend four tests common in classical regression - Wald, score, likelihood ratio and F tests - to functional linear regression, for testing the null hypothesis, that there is no association between a scalar response and a functional covariate. Using functional principal component analysis, we re-express the functional linear model as a standard linear model, where the effect of the functional covariate can be approximated by a finite linear combination of the functional principal component scores. In this setting, we consider application of the four traditional tests. The proposed testing procedures are investigated theoretically for densely observed functional covariates when the number of principal components diverges. Using the theoretical distribution of the tests under the alternative hypothesis, we develop a procedure for sample size calculation in the context of functional linear regression. The four tests are further compared numerically for both densely and sparsely observed noisy functional data in simulation experiments and using two real data applications.
Classical Testing in Functional Linear Models
Kong, Dehan; Staicu, Ana-Maria; Maity, Arnab
2016-01-01
We extend four tests common in classical regression - Wald, score, likelihood ratio and F tests - to functional linear regression, for testing the null hypothesis, that there is no association between a scalar response and a functional covariate. Using functional principal component analysis, we re-express the functional linear model as a standard linear model, where the effect of the functional covariate can be approximated by a finite linear combination of the functional principal component scores. In this setting, we consider application of the four traditional tests. The proposed testing procedures are investigated theoretically for densely observed functional covariates when the number of principal components diverges. Using the theoretical distribution of the tests under the alternative hypothesis, we develop a procedure for sample size calculation in the context of functional linear regression. The four tests are further compared numerically for both densely and sparsely observed noisy functional data in simulation experiments and using two real data applications. PMID:28955155
Suggestions for presenting the results of data analyses
Anderson, David R.; Link, William A.; Johnson, Douglas H.; Burnham, Kenneth P.
2001-01-01
We give suggestions for the presentation of research results from frequentist, information-theoretic, and Bayesian analysis paradigms, followed by several general suggestions. The information-theoretic and Bayesian methods offer alternative approaches to data analysis and inference compared to traditionally used methods. Guidance is lacking on the presentation of results under these alternative procedures and on nontesting aspects of classical frequentists methods of statistical analysis. Null hypothesis testing has come under intense criticism. We recommend less reporting of the results of statistical tests of null hypotheses in cases where the null is surely false anyway, or where the null hypothesis is of little interest to science or management.
Code of Federal Regulations, 2013 CFR
2013-07-01
... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...
Code of Federal Regulations, 2014 CFR
2014-07-01
... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...
Code of Federal Regulations, 2012 CFR
2012-07-01
... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...
Code of Federal Regulations, 2011 CFR
2011-07-01
... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...
Code of Federal Regulations, 2010 CFR
2010-07-01
... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...
Alternative Strategies in Assessing Special Education Needs
ERIC Educational Resources Information Center
Dykeman, Bruce F.
2006-01-01
The conventional use of standardized testing within a discrepancy analysis model is reviewed. The Response-to-Intervention (RTI) process is explained, along with descriptions of assessment procedures within RTI: functional assessment, authentic assessment, curriculum-based measurement, and play-based assessment. Psychometric issues relevant to RTI…
40 CFR 7.170 - Alternative funds disbursal procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Alternative funds disbursal procedures. 7.170 Section 7.170 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL... Discrimination Prohibited on the Basis of Age § 7.170 Alternative funds disbursal procedures. (a) When EPA...
21 CFR 640.120 - Alternative procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Alternative procedures. 640.120 Section 640.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Alternative Procedures § 640.120...
21 CFR 640.120 - Alternative procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Alternative procedures. 640.120 Section 640.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Alternative Procedures § 640.120...
44 CFR 7.948 - Alternate funds disbursal procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Alternate funds disbursal... Investigation, Conciliation, and Enforcement Procedures § 7.948 Alternate funds disbursal procedure. (a) When FEMA withholds funds from recipient under this regulation, the Administrator may, if allowable under...
Lina, Ioan A; Lauer, Amanda M
2013-04-01
The notched noise method is an effective procedure for measuring frequency resolution and auditory filter shapes in both human and animal models of hearing. Briefly, auditory filter shape and bandwidth estimates are derived from masked thresholds for tones presented in noise containing widening spectral notches. As the spectral notch widens, increasingly less of the noise falls within the auditory filter and the tone becomes more detectible until the notch width exceeds the filter bandwidth. Behavioral procedures have been used for the derivation of notched noise auditory filter shapes in mice; however, the time and effort needed to train and test animals on these tasks renders a constraint on the widespread application of this testing method. As an alternative procedure, we combined relatively non-invasive auditory brainstem response (ABR) measurements and the notched noise method to estimate auditory filters in normal-hearing mice at center frequencies of 8, 11.2, and 16 kHz. A complete set of simultaneous masked thresholds for a particular tone frequency were obtained in about an hour. ABR-derived filter bandwidths broadened with increasing frequency, consistent with previous studies. The ABR notched noise procedure provides a fast alternative to estimating frequency selectivity in mice that is well-suited to high through-put or time-sensitive screening. Copyright © 2013 Elsevier B.V. All rights reserved.
Operator procedure verification with a rapidly reconfigurable simulator
NASA Technical Reports Server (NTRS)
Iwasaki, Yumi; Engelmore, Robert; Fehr, Gary; Fikes, Richard
1994-01-01
Generating and testing procedures for controlling spacecraft subsystems composed of electro-mechanical and computationally realized elements has become a very difficult task. Before a spacecraft can be flown, mission controllers must envision a great variety of situations the flight crew may encounter during a mission and carefully construct procedures for operating the spacecraft in each possible situation. If, despite extensive pre-compilation of control procedures, an unforeseen situation arises during a mission, the mission controller must generate a new procedure for the flight crew in a limited amount of time. In such situations, the mission controller cannot systematically consider and test alternative procedures against models of the system being controlled, because the available simulator is too large and complex to reconfigure, run, and analyze quickly. A rapidly reconfigurable simulation environment that can execute a control procedure and show its effects on system behavior would greatly facilitate generation and testing of control procedures both before and during a mission. The How Things Work project at Stanford University has developed a system called DME (Device Modeling Environment) for modeling and simulating the behavior of electromechanical devices. DME was designed to facilitate model formulation and behavior simulation of device behavior including both continuous and discrete phenomena. We are currently extending DME for use in testing operator procedures, and we have built a knowledge base for modeling the Reaction Control System (RCS) of the space shuttle as a testbed. We believe that DME can facilitate design of operator procedures by providing mission controllers with a simulation environment that meets all these requirements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, V.E.
1979-10-01
The standard maximum likelihood and moment estimation procedures are shown to have some undesirable characteristics for estimating the parameters in a three-parameter lognormal distribution. A class of goodness-of-fit estimators is found which provides a useful alternative to the standard methods. The class of goodness-of-fit tests considered include the Shapiro-Wilk and Shapiro-Francia tests which reduce to a weighted linear combination of the order statistics that can be maximized in estimation problems. The weighted-order statistic estimators are compared to the standard procedures in Monte Carlo simulations. Bias and robustness of the procedures are examined and example data sets analyzed including geochemical datamore » from the National Uranium Resource Evaluation Program.« less
Ruberu, S R; Langlois, G W; Masuda, M; Perera, S Kusum
2012-01-01
The receptor-binding assay (RBA) method for determining saxatoxin (STX) and its numerous analogues, which cause paralytic shellfish poisoning (PSP) in humans, was evaluated in a single laboratory study. Each step of the assay preparation procedure including the performance of the multi-detector TopCount® instrument was evaluated for its contribution to method variability. The overall inherent RBA variability was determined to be 17%. Variability within the 12 detectors was observed; however, there was no reproducible pattern in detector performance. This observed variability among detectors could be attributed to other factors, such as pipetting errors. In an attempt to reduce the number of plates rejected due to excessive variability in the method's quality control parameters, a statistical approach was evaluated using either Grubbs' test or the Student's t-test for rejecting outliers in the measurement of triplicate wells. This approach improved the ratio of accepted versus rejected plates, saving cost and time for rerunning the assay. However, the potential reduction in accuracy and the lack of improvement in precision suggests caution when using this approach. The current study has recommended an alternate quality control procedure for accepting or rejecting plates in place of the criteria currently used in the published assay, or the alternative of outlier testing. The recommended procedure involves the development of control charts to monitor the critical parameters identified in the published method (QC sample, EC₅₀, slope of calibration curve), with the addition of a fourth critical parameter which is the top value (100% binding) of the calibration curve.
Lillicrap, Adam; Belanger, Scott; Burden, Natalie; Pasquier, David Du; Embry, Michelle R; Halder, Marlies; Lampi, Mark A; Lee, Lucy; Norberg-King, Teresa; Rattner, Barnett A; Schirmer, Kristin; Thomas, Paul
2016-11-01
The need for alternative approaches to the use of vertebrate animals for hazard assessment of chemicals and pollutants has become of increasing importance. It is now the first consideration when initiating a vertebrate ecotoxicity test, to ensure that unnecessary use of vertebrate organisms is minimized wherever possible. For some regulatory purposes, the use of vertebrate organisms for environmental risk assessments has been banned; in other situations, the number of organisms tested has been dramatically reduced or the severity of the procedure refined. However, there is still a long way to go to achieve a complete replacement of vertebrate organisms to generate environmental hazard data. The development of animal alternatives is based not just on ethical considerations but also on reducing the cost of performing vertebrate ecotoxicity tests and in some cases on providing better information aimed at improving environmental risk assessments. The present Focus article provides an overview of the considerable advances that have been made toward alternative approaches for ecotoxicity assessments over the last few decades. Environ Toxicol Chem 2016;35:2637-2646. © 2016 SETAC. © 2016 SETAC.
Inference for High-dimensional Differential Correlation Matrices.
Cai, T Tony; Zhang, Anru
2016-01-01
Motivated by differential co-expression analysis in genomics, we consider in this paper estimation and testing of high-dimensional differential correlation matrices. An adaptive thresholding procedure is introduced and theoretical guarantees are given. Minimax rate of convergence is established and the proposed estimator is shown to be adaptively rate-optimal over collections of paired correlation matrices with approximately sparse differences. Simulation results show that the procedure significantly outperforms two other natural methods that are based on separate estimation of the individual correlation matrices. The procedure is also illustrated through an analysis of a breast cancer dataset, which provides evidence at the gene co-expression level that several genes, of which a subset has been previously verified, are associated with the breast cancer. Hypothesis testing on the differential correlation matrices is also considered. A test, which is particularly well suited for testing against sparse alternatives, is introduced. In addition, other related problems, including estimation of a single sparse correlation matrix, estimation of the differential covariance matrices, and estimation of the differential cross-correlation matrices, are also discussed.
Initial flight test of a Loran-C receiver/data collection system
NASA Technical Reports Server (NTRS)
Fischer, J. P.; Nickum, J. D.
1978-01-01
Development of a low cost Loran C receiver for general aviation use is discussed. The preparation and procedure of a flight test conducted with a receiver design which utilizes a phase locked loop oscillator to track the Loran C signals is described. It is indicated that such a receiver is a viable alternative for future work in developing a low cost Loran-C navigator.
40 CFR Appendix A-6 to Part 60 - Test Methods 16 through 18
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperatures) are to be used either in addition to, or as a substitute for procedures in a test method... maintaining the probe, filter box, and connections at a temperature of at least 120 °C (248 °F). Moisture is... temperature is above 0 °C (32 °F). Alternatively, moisture may be eliminated by heating the sample line, and...
Simulating the Use of Alternative Fuels in a Turbofan Engine
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Chin, Jeffrey Chevoor; Liu, Yuan
2013-01-01
The interest in alternative fuels for aviation has created a need to evaluate their effect on engine performance. The use of dynamic turbofan engine simulations enables the comparative modeling of the performance of these fuels on a realistic test bed in terms of dynamic response and control compared to traditional fuels. The analysis of overall engine performance and response characteristics can lead to a determination of the practicality of using specific alternative fuels in commercial aircraft. This paper describes a procedure to model the use of alternative fuels in a large commercial turbofan engine, and quantifies their effects on engine and vehicle performance. In addition, the modeling effort notionally demonstrates that engine performance may be maintained by modifying engine control system software parameters to account for the alternative fuel.
46 CFR 71.50-25 - Alternative Hull Examination (AHE) procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Alternative Hull Examination (AHE) procedure. 71.50-25... INSPECTION AND CERTIFICATION Drydocking § 71.50-25 Alternative Hull Examination (AHE) procedure. (a) To complete the underwater survey you must— (1) Perform a general examination of the underwater hull plating...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Alternative compliance procedure. 435.305 Section 435.305... Alternative compliance procedure. (a) If a proposed building design includes unusual or innovative energy... estimated unit energy cost on the compliance forms, on the basis of selecting the optimum levels on the...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Alternative compliance procedure. 435.305 Section 435.305... Alternative compliance procedure. (a) If a proposed building design includes unusual or innovative energy... estimated unit energy cost on the compliance forms, on the basis of selecting the optimum levels on the...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Alternative compliance procedure. 435.305 Section 435.305... Alternative compliance procedure. (a) If a proposed building design includes unusual or innovative energy... estimated unit energy cost on the compliance forms, on the basis of selecting the optimum levels on the...
27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or procedures...
27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or procedures...
27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or procedures...
27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or procedures...
27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or procedures...
Building Intuitions about Statistical Inference Based on Resampling
ERIC Educational Resources Information Center
Watson, Jane; Chance, Beth
2012-01-01
Formal inference, which makes theoretical assumptions about distributions and applies hypothesis testing procedures with null and alternative hypotheses, is notoriously difficult for tertiary students to master. The debate about whether this content should appear in Years 11 and 12 of the "Australian Curriculum: Mathematics" has gone on…
ERIC Educational Resources Information Center
School Science Review, 1984
1984-01-01
Describes: (1) a microcomputer demonstration of autocatalysis; (2) a safe alternative to ethanol and methanol; (3) a simple condenser for test-tube reactions; (4) a new procedure for studying the magnetic properties of transition metal compounds; (5) plasticization of the polymer PVC; and (6) some thoughts on polybasic acids and their salts. (JN)
Research Strategies in Higher Education.
ERIC Educational Resources Information Center
Semb, George
The present paper outlines two alternative strategies for evaluating teaching effectiveness. These are: (1) within-subject reversal designs, and (2) multiple baseline testing procedures. Each design is discussed in terms of its application to research problems in higher education. In reversal designs, the student is exposed to different teaching…
Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design
NASA Astrophysics Data System (ADS)
Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana
2015-12-01
During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu
2015-04-15
PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose,more » radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.« less
48 CFR 715.370 - Alternative source selection procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... selection procedures. 715.370 Section 715.370 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Source Selection 715.370 Alternative source selection procedures. The following selection procedures may be used, when...
Volokhov, Dmitriy V; Graham, Laurie J; Brorson, Kurt A; Chizhikov, Vladimir E
2011-01-01
Mycoplasmas, particularly species of the genera Mycoplasma and Acholeplasma, are known to be occasional microbial contaminants of cell cultures that produce biologics. This presents a serious concern regarding the risk of mycoplasma contamination for research laboratories and commercial facilities developing and manufacturing cell-derived biological and biopharmaceutical products for therapeutic use. Potential undetected contamination of these products or process intermediates with mycoplasmas represents a potential safety risk for patients and a business risk for producers of biopharmaceuticals. To minimize these risks, monitoring for adventitious agents, such as viruses and mycoplasmas, is performed during the manufacture of biologics produced in cell culture substrates. The "gold standard" microbiological assay, currently recommended by the USP, EP, JP and the US FDA, for the mycoplasma testing of biologics, involves the culture of viable mycoplasmas in broth, agar plates and indicator cells. Although the procedure enables highly efficient mycoplasma detection in cell substrates and cell-derived products, the overall testing strategy is time consuming (a minimum of 28 days) and requires skilled interpretation of the results. The long time period required for these conventional assays does not permit their use for products with short shelf-lives or for timely 'go/no-go' decisions during routine in-process testing. PCR methodology has existed for decades, however PCR based and other alternative methods for mycoplasma detection have only recently been considered for application to biologics manufacture. The application of alternative nucleic acid-based, enzyme-based and/or recombinant cell-culture methods, particularly in combination with efficient sample preparation procedures, could provide advantages over conventional microbiological methods in terms of analytical throughput, simplicity, and turnaround time. However, a challenge to the application of alternative methods for detection of mycoplasmas remains whether these alternative methods can provide a limit of detection comparable or superior to those of the culture methods. An additional challenge is that nucleic acid amplification technique (NAT) methods do not allow for accurate discrimination between viable and non-viable mycoplasma contaminants, which might lead to false-positive results (e.g. from inactivated raw materials, etc.). Our review provides an overview of these alternative methods and discusses the pros and cons of their application for the testing of mycoplasmas in biologics and cell substrates. Published by Elsevier Ltd.
A default Bayesian hypothesis test for mediation.
Nuijten, Michèle B; Wetzels, Ruud; Matzke, Dora; Dolan, Conor V; Wagenmakers, Eric-Jan
2015-03-01
In order to quantify the relationship between multiple variables, researchers often carry out a mediation analysis. In such an analysis, a mediator (e.g., knowledge of a healthy diet) transmits the effect from an independent variable (e.g., classroom instruction on a healthy diet) to a dependent variable (e.g., consumption of fruits and vegetables). Almost all mediation analyses in psychology use frequentist estimation and hypothesis-testing techniques. A recent exception is Yuan and MacKinnon (Psychological Methods, 14, 301-322, 2009), who outlined a Bayesian parameter estimation procedure for mediation analysis. Here we complete the Bayesian alternative to frequentist mediation analysis by specifying a default Bayesian hypothesis test based on the Jeffreys-Zellner-Siow approach. We further extend this default Bayesian test by allowing a comparison to directional or one-sided alternatives, using Markov chain Monte Carlo techniques implemented in JAGS. All Bayesian tests are implemented in the R package BayesMed (Nuijten, Wetzels, Matzke, Dolan, & Wagenmakers, 2014).
Hand gestures support word learning in patients with hippocampal amnesia.
Hilverman, Caitlin; Cook, Susan Wagner; Duff, Melissa C
2018-06-01
Co-speech hand gesture facilitates learning and memory, yet the cognitive and neural mechanisms supporting this remain unclear. One possibility is that motor information in gesture may engage procedural memory representations. Alternatively, iconic information from gesture may contribute to declarative memory representations mediated by the hippocampus. To investigate these alternatives, we examined gesture's effects on word learning in patients with hippocampal damage and declarative memory impairment, with intact procedural memory, and in healthy and in brain-damaged comparison groups. Participants learned novel label-object pairings while producing gesture, observing gesture, or observing without gesture. After a delay, recall and object identification were assessed. Unsurprisingly, amnesic patients were unable to recall the labels at test. However, they correctly identified objects at above chance levels, but only if they produced a gesture at encoding. Comparison groups performed well above chance at both recall and object identification regardless of gesture. These findings suggest that gesture production may support word learning by engaging nondeclarative (procedural) memory. © 2018 Wiley Periodicals, Inc.
76 FR 69869 - Energy Conservation Program: Test Procedures for Residential Clothes Washers
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-09
... manual water fill control system, user- adjustable adaptive water fill control system, or adaptive water fill control system with alternate manual water fill control system, use the water fill selector... and transcripts, comments, and other supporting documents/ materials. All documents in the docket are...
40 CFR 60.547 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Method 24 or formulation data for the determination of the VOC content of cements or green tire spray materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... corrected using an experimentally determined response factor comparing the alternative calibration gas to...
40 CFR 60.547 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Method 24 or formulation data for the determination of the VOC content of cements or green tire spray materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... corrected using an experimentally determined response factor comparing the alternative calibration gas to...
40 CFR 60.463 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operator shall use the following procedures for determining monthly volume-weighted average emissions of... Method 24 or an equivalent or alternative method. The owner or operator shall determine the volume of... facilities, the owner or operator shall estimate the volume of coating used at each affected facility by...
Di Nardo, Francesco; Mengoni, Michele; Morettini, Micaela
2013-05-01
Present study provides a novel MATLAB-based parameter estimation procedure for individual assessment of hepatic insulin degradation (HID) process from standard frequently-sampled intravenous glucose tolerance test (FSIGTT) data. Direct access to the source code, offered by MATLAB, enabled us to design an optimization procedure based on the alternating use of Gauss-Newton's and Levenberg-Marquardt's algorithms, which assures the full convergence of the process and the containment of computational time. Reliability was tested by direct comparison with the application, in eighteen non-diabetic subjects, of well-known kinetic analysis software package SAAM II, and by application on different data. Agreement between MATLAB and SAAM II was warranted by intraclass correlation coefficients ≥0.73; no significant differences between corresponding mean parameter estimates and prediction of HID rate; and consistent residual analysis. Moreover, MATLAB optimization procedure resulted in a significant 51% reduction of CV% for the worst-estimated parameter by SAAM II and in maintaining all model-parameter CV% <20%. In conclusion, our MATLAB-based procedure was suggested as a suitable tool for the individual assessment of HID process. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Robust Approach to Verifying the Weak Form of the Efficient Market Hypothesis
NASA Astrophysics Data System (ADS)
Střelec, Luboš
2011-09-01
The weak form of the efficient markets hypothesis states that prices incorporate only past information about the asset. An implication of this form of the efficient markets hypothesis is that one cannot detect mispriced assets and consistently outperform the market through technical analysis of past prices. One of possible formulations of the efficient market hypothesis used for weak form tests is that share prices follow a random walk. It means that returns are realizations of IID sequence of random variables. Consequently, for verifying the weak form of the efficient market hypothesis, we can use distribution tests, among others, i.e. some tests of normality and/or some graphical methods. Many procedures for testing the normality of univariate samples have been proposed in the literature [7]. Today the most popular omnibus test of normality for a general use is the Shapiro-Wilk test. The Jarque-Bera test is the most widely adopted omnibus test of normality in econometrics and related fields. In particular, the Jarque-Bera test (i.e. test based on the classical measures of skewness and kurtosis) is frequently used when one is more concerned about heavy-tailed alternatives. As these measures are based on moments of the data, this test has a zero breakdown value [2]. In other words, a single outlier can make the test worthless. The reason so many classical procedures are nonrobust to outliers is that the parameters of the model are expressed in terms of moments, and their classical estimators are expressed in terms of sample moments, which are very sensitive to outliers. Another approach to robustness is to concentrate on the parameters of interest suggested by the problem under this study. Consequently, novel robust testing procedures of testing normality are presented in this paper to overcome shortcomings of classical normality tests in the field of financial data, which are typical with occurrence of remote data points and additional types of deviations from normality. This study also discusses some results of simulation power studies of these tests for normality against selected alternatives. Based on outcome of the power simulation study, selected normality tests were consequently used to verify weak form of efficiency in Central Europe stock markets.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-24
...This document proposes to amend Federal Motor Vehicle Safety Standard (FMVSS) No. 213, Child Restraint Systems, regarding a Hybrid III 10-year-old child test dummy that the agency seeks to use in the compliance test procedures of the standard. This document supplements a 2005 notice of proposed rulemaking (NPRM) and a 2008 SNPRM previously published in this rulemaking (RIN 2127-AJ44) regarding this test dummy. In the 2005 NPRM, in response to Anton's Law, NHTSA proposed to adopt the 10-year-old child test dummy into FMVSS No. 213 to test child restraints for older children. Subsequently, to address variation that was found in dummy readings due to chin-to-chest contact, NHTSA published the 2008 SNPRM to propose a NHTSA-developed procedure for positioning the test dummy in belt-positioning seats. Comments on the SNPRM objected to the positioning procedure, and some suggested an alternative procedure developed by the University of Michigan Transportation Research Institute (UMTRI). Today's SNPRM proposes to use the UMTRI procedure to position the test dummy rather than the NHTSA-developed procedure. We note that the 10-year-old child dummy may sometimes experience stiff contact between its chin and upper sternal bib region which may result in an unrealistically high value of the head injury criterion (HIC) \\1\\ referenced in the standard. Accordingly, NHTSA proposes that the dummy's HIC measurement will not be used to assess the compliance of the tested child restraint. This SNPRM also proposes other amendments to FMVSS No. 213, including a proposal to permit NHTSA to use, at the manufacturer's option, the Hybrid II or Hybrid III versions of the 6-year-old test dummy, and a proposal to use the UMTRI procedure to position the Hybrid III 6-year- old and 10-year-old dummies when testing belt-positioning seats. ---------------------------------------------------------------------------
1980-10-01
surface (i.e., from 10 m above the ground plane) to a height greater than the greatest height of the airplanc . during the time when PNLT is within test...8217The rule expressed by Eq. (86) was adopted to avoid creatIng values for retFerence-day hand hiound pre’ssurt, 1 Ve is whtu thv, test-L Iime sound
NASA Technical Reports Server (NTRS)
Abbey, Craig K.; Eckstein, Miguel P.
2002-01-01
We consider estimation and statistical hypothesis testing on classification images obtained from the two-alternative forced-choice experimental paradigm. We begin with a probabilistic model of task performance for simple forced-choice detection and discrimination tasks. Particular attention is paid to general linear filter models because these models lead to a direct interpretation of the classification image as an estimate of the filter weights. We then describe an estimation procedure for obtaining classification images from observer data. A number of statistical tests are presented for testing various hypotheses from classification images based on some more compact set of features derived from them. As an example of how the methods we describe can be used, we present a case study investigating detection of a Gaussian bump profile.
A function-based approach to cockpit procedure aids
NASA Technical Reports Server (NTRS)
Phatak, Anil V.; Jain, Parveen; Palmer, Everett
1990-01-01
The objective of this research is to develop and test a cockpit procedural aid that can compose and present procedures that are appropriate for the given flight situation. The procedure would indicate the status of the aircraft engineering systems, and the environmental conditions. Prescribed procedures already exist for normal as well as for a number of non-normal and emergency situations, and can be presented to the crew using an interactive cockpit display. However, no procedures are prescribed or recommended for a host of plausible flight situations involving multiple malfunctions compounded by adverse environmental conditions. Under these circumstances, the cockpit procedural aid must review the prescribed procedures for the individual malfunction (when available), evaluate the alternatives or options, and present one or more composite procedures (prioritized or unprioritized) in response to the given situation. A top-down function-based conceptual approach towards composing and presenting cockpit procedures is being investigated. This approach is based upon the thought process that an operating crew must go through while attempting to meet the flight objectives given the current flight situation. In order to accomplish the flight objectives, certain critical functions must be maintained during each phase of the flight, using the appropriate procedures or success paths. The viability of these procedures depends upon the availability of required resources. If resources available are not sufficient to meet the requirements, alternative procedures (success paths) using the available resources must be constructed to maintain the critical functions and the corresponding objectives. If no success path exists that can satisfy the critical functions/objectives, then the next level of critical functions/objectives must be selected and the process repeated. Information is given in viewgraph form.
5 CFR 2634.905 - Use of alternative procedures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... may use an alternative procedure in lieu of filing the OGE Form 450 or OGE Optional Form 450-A. The alternative procedure may be an agency-specific form to be filed in place thereof. An agency must submit for... that there is no such relationship, she signs and dates a certification which verifies that she has...
5 CFR 2634.905 - Use of alternative procedures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... may use an alternative procedure in lieu of filing the OGE Form 450 or OGE Optional Form 450-A. The alternative procedure may be an agency-specific form to be filed in place thereof. An agency must submit for... that there is no such relationship, she signs and dates a certification which verifies that she has...
5 CFR 2634.905 - Use of alternative procedures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... may use an alternative procedure in lieu of filing the OGE Form 450 or OGE Optional Form 450-A. The alternative procedure may be an agency-specific form to be filed in place thereof. An agency must submit for... that there is no such relationship, she signs and dates a certification which verifies that she has...
5 CFR 2634.905 - Use of alternative procedures.
Code of Federal Regulations, 2011 CFR
2011-01-01
... may use an alternative procedure in lieu of filing the OGE Form 450 or OGE Optional Form 450-A. The alternative procedure may be an agency-specific form to be filed in place thereof. An agency must submit for... that there is no such relationship, she signs and dates a certification which verifies that she has...
Dahling, D R; Wright, B A
1988-12-01
An improved concentration method using sample volumes as large as 1500 ml has been developed to monitor for viruses in wastewaters. Non-precipitating dry beef extract powder is added to wastewater samples to give a 3% concentration and mixed until dissolved. This is followed by the addition of Celite as a virus adsorbent. By manipulating pH, viruses are eluted from the Celite in small volumes of phosphate buffer. This procedure was further tested without the aid of the Celite additives using a precipitating beef extract powder and substituting FeCl3 as an alternate reagent for the Celite. Comparison testing was also made with the currently recommended cartridge and disc filter procedures. In all cases, the non-precipitating beef extract-Celite method gave higher recovery rates in highly polluted waters.
Arrest procedures for driving while intoxicated
DOT National Transportation Integrated Search
1980-08-01
Model arrest procedures were developed to enhance the enforcement of laws against driving while intoxicated (DWI). Development was based on answers obtained to the following questions: what procedural alternatives are now possible; how do alternative...
Simulation-based hypothesis testing of high dimensional means under covariance heterogeneity.
Chang, Jinyuan; Zheng, Chao; Zhou, Wen-Xin; Zhou, Wen
2017-12-01
In this article, we study the problem of testing the mean vectors of high dimensional data in both one-sample and two-sample cases. The proposed testing procedures employ maximum-type statistics and the parametric bootstrap techniques to compute the critical values. Different from the existing tests that heavily rely on the structural conditions on the unknown covariance matrices, the proposed tests allow general covariance structures of the data and therefore enjoy wide scope of applicability in practice. To enhance powers of the tests against sparse alternatives, we further propose two-step procedures with a preliminary feature screening step. Theoretical properties of the proposed tests are investigated. Through extensive numerical experiments on synthetic data sets and an human acute lymphoblastic leukemia gene expression data set, we illustrate the performance of the new tests and how they may provide assistance on detecting disease-associated gene-sets. The proposed methods have been implemented in an R-package HDtest and are available on CRAN. © 2017, The International Biometric Society.
Information processing requirements for on-board monitoring of automatic landing
NASA Technical Reports Server (NTRS)
Sorensen, J. A.; Karmarkar, J. S.
1977-01-01
A systematic procedure is presented for determining the information processing requirements for on-board monitoring of automatic landing systems. The monitoring system detects landing anomalies through use of appropriate statistical tests. The time-to-correct aircraft perturbations is determined from covariance analyses using a sequence of suitable aircraft/autoland/pilot models. The covariance results are used to establish landing safety and a fault recovery operating envelope via an event outcome tree. This procedure is demonstrated with examples using the NASA Terminal Configured Vehicle (B-737 aircraft). The procedure can also be used to define decision height, assess monitoring implementation requirements, and evaluate alternate autoland configurations.
27 CFR 26.331 - Alternate methods or procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or... Miscellaneous Provisions § 26.331 Alternate methods or procedures. (a) Application. A person bringing liquors into the United States from Puerto Rico or the Virgin Islands who desires to use an alternate method or...
Analytical procedures for environmental quality control. Volume 2. Technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, L.K.; Wang, M.H.S.
1989-01-15
This report covers sixteen important documents. Some examples are: The determination of the maximum total trihalomethane potential; Nationwide approval of alternative test procedure for analysis of trihalomethanes; Volatile organic compounds in eater by purge and trap capillary column gas chromatography with photoionization and electrolytic conductivity detectors in series; Analysis of organohalide pesticides and arclors in drinking water by microextraction and gas chromatography; Testing for lead in school drinking water; Simplified methods for food and feed testing; Determination of nitroaromatic compounds and isophorone in industrial and municipal wastewaters; Sampling for giardia and/or cryptosporidium; determination of TCDD in industrial and municipal wastewaters;more » Determination of volatile organics in industrial and municipal wastewaters; Determination of polynuclear aromatic hydrocarbons in industrial and municipal wastewaters.« less
Müller, Jana Annina; Wendt, Dorothea; Kollmeier, Birger; Brand, Thomas
2016-01-01
The aim of this study was to validate a procedure for performing the audio-visual paradigm introduced by Wendt et al. (2015) with reduced practical challenges. The original paradigm records eye fixations using an eye tracker and calculates the duration of sentence comprehension based on a bootstrap procedure. In order to reduce practical challenges, we first reduced the measurement time by evaluating a smaller measurement set with fewer trials. The results of 16 listeners showed effects comparable to those obtained when testing the original full measurement set on a different collective of listeners. Secondly, we introduced electrooculography as an alternative technique for recording eye movements. The correlation between the results of the two recording techniques (eye tracker and electrooculography) was r = 0.97, indicating that both methods are suitable for estimating the processing duration of individual participants. Similar changes in processing duration arising from sentence complexity were found using the eye tracker and the electrooculography procedure. Thirdly, the time course of eye fixations was estimated with an alternative procedure, growth curve analysis, which is more commonly used in recent studies analyzing eye tracking data. The results of the growth curve analysis were compared with the results of the bootstrap procedure. Both analysis methods show similar processing durations. PMID:27764125
Stress corrosion evaluation of HP 9Ni-4Co-0.20C steel
NASA Technical Reports Server (NTRS)
Torres, Pablo D.
1993-01-01
A stress corrosion cracking (SCC) evaluation was undertaken on HP 9Ni-4Co-0.20C steel in support of the Advanced Solid Rocket Motor (ASRM) program. This alloy was tested in plate, bar, and ring forging forms. Several heat treating procedures yielded ultimate tensile strengths ranging from 1,407 to 1,489 MPa (204 to 216 ksi). The test environments were high humidity, alternate immersion in 3.5-percent NaCl, and 5-percent salt spray. Stress levels ranged from 25 to 90 percent of the yield strengths. The majority of the tests were conducted for 90 days. Even though the specimens rusted significantly in salt spray and alternate immersion, no failures occurred. Therefore, it can be concluded that this alloy, in the forms and at the strength levels tested, is highly resistant to SCC in salt and high humidity environments.
Optimal decision making on the basis of evidence represented in spike trains.
Zhang, Jiaxiang; Bogacz, Rafal
2010-05-01
Experimental data indicate that perceptual decision making involves integration of sensory evidence in certain cortical areas. Theoretical studies have proposed that the computation in neural decision circuits approximates statistically optimal decision procedures (e.g., sequential probability ratio test) that maximize the reward rate in sequential choice tasks. However, these previous studies assumed that the sensory evidence was represented by continuous values from gaussian distributions with the same variance across alternatives. In this article, we make a more realistic assumption that sensory evidence is represented in spike trains described by the Poisson processes, which naturally satisfy the mean-variance relationship observed in sensory neurons. We show that for such a representation, the neural circuits involving cortical integrators and basal ganglia can approximate the optimal decision procedures for two and multiple alternative choice tasks.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... to Electrolux Home Products, Inc. (Electrolux) a waiver from the DOE electric refrigerator and... using an alternate test procedure that takes this technology into account when measuring energy.... Michael G. Raymond, U.S. Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-29
... moisture. According to the petitioner, Electrolux's technology is similar to that used by General Electric...-012) that grants to Electrolux Home Products, Inc. (Electrolux) a waiver from the DOE electric... alternate test procedure that takes this technology into account when measuring energy consumption. DATES...
46 CFR 115.645 - Alternative Hull Examination (AHE) Procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Allow access to all internal areas of the hull for examination, except internal tanks that carry fuel... potable water tanks may be examined visually or by non-destructive testing to the satisfaction of the... the extent of damage or to effect permanent repairs if the assessment or repairs cannot be completed...
46 CFR 71.50-25 - Alternative Hull Examination (AHE) procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... areas of the hull for examination, except internal tanks that carry fuel, sewage, or potable water. Internal tanks that carry fuel must be examined in accordance with § 71.53-1 of this part. Internal sewage and potable water tanks may be examined visually or by non-destructive testing to the satisfaction of...
46 CFR 71.50-25 - Alternative Hull Examination (AHE) procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... areas of the hull for examination, except internal tanks that carry fuel, sewage, or potable water. Internal tanks that carry fuel must be examined in accordance with § 71.53-1 of this part. Internal sewage and potable water tanks may be examined visually or by non-destructive testing to the satisfaction of...
46 CFR 115.645 - Alternative Hull Examination (AHE) Procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Allow access to all internal areas of the hull for examination, except internal tanks that carry fuel... potable water tanks may be examined visually or by non-destructive testing to the satisfaction of the... the extent of damage or to effect permanent repairs if the assessment or repairs cannot be completed...
46 CFR 115.645 - Alternative Hull Examination (AHE) Procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Allow access to all internal areas of the hull for examination, except internal tanks that carry fuel... potable water tanks may be examined visually or by non-destructive testing to the satisfaction of the... the extent of damage or to effect permanent repairs if the assessment or repairs cannot be completed...
46 CFR 71.50-25 - Alternative Hull Examination (AHE) procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... areas of the hull for examination, except internal tanks that carry fuel, sewage, or potable water. Internal tanks that carry fuel must be examined in accordance with § 71.53-1 of this part. Internal sewage and potable water tanks may be examined visually or by non-destructive testing to the satisfaction of...
46 CFR 115.645 - Alternative Hull Examination (AHE) Procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Allow access to all internal areas of the hull for examination, except internal tanks that carry fuel... potable water tanks may be examined visually or by non-destructive testing to the satisfaction of the... the extent of damage or to effect permanent repairs if the assessment or repairs cannot be completed...
46 CFR 71.50-25 - Alternative Hull Examination (AHE) procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... areas of the hull for examination, except internal tanks that carry fuel, sewage, or potable water. Internal tanks that carry fuel must be examined in accordance with § 71.53-1 of this part. Internal sewage and potable water tanks may be examined visually or by non-destructive testing to the satisfaction of...
Developmental Dissociation in the Neural Responses to Simple Multiplication and Subtraction Problems
ERIC Educational Resources Information Center
Prado, Jérôme; Mutreja, Rachna; Booth, James R.
2014-01-01
Mastering single-digit arithmetic during school years is commonly thought to depend upon an increasing reliance on verbally memorized facts. An alternative model, however, posits that fluency in single-digit arithmetic might also be achieved via the increasing use of efficient calculation procedures. To test between these hypotheses, we used a…
Automatic Scoring of Paper-and-Pencil Figural Responses. Research Report.
ERIC Educational Resources Information Center
Martinez, Michael E.; And Others
Large-scale testing is dominated by the multiple-choice question format. Widespread use of the format is due, in part, to the ease with which multiple-choice items can be scored automatically. This paper examines automatic scoring procedures for an alternative item type: figural response. Figural response items call for the completion or…
Role of Mitochondrial Inheritance on Prostate Cancer Outcome in African-American Men
2014-10-01
prostate cancer cell line cybrids was not effective and we have instead decided to use the Rhodamine -6-G procedure. Thus far PNT1A cybrid cell lines...the original protocol. To overcome these difficulties, we tested multiple alternative approaches including rhodamine -6G (R6G) mediated short-term
Role of Mitochondrial Inheritance on Prostate Cancer Outcome in African American Men
2015-12-01
for generating prostate cancer cell line cybrids was not effective and we have instead used a Rhodamine -6-G procedure. PNT1A cybrid cell lines have...difficulties, we tested multiple alternative approaches including rhodamine -6G (R6G) mediated short-term mitochondrial dysfunction in generating rho zero cells
How Often Is p[subscript rep] Close to the True Replication Probability?
ERIC Educational Resources Information Center
Trafimow, David; MacDonald, Justin A.; Rice, Stephen; Clason, Dennis L.
2010-01-01
Largely due to dissatisfaction with the standard null hypothesis significance testing procedure, researchers have begun to consider alternatives. For example, Killeen (2005a) has argued that researchers should calculate p[subscript rep] that is purported to indicate the probability that, if the experiment in question were replicated, the obtained…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-28
... of semivolatile organic compounds in finished drinking water. The method analytes are extracted and... semivolatile organic contaminants: Alachlor, atrazine, polychlorinated biphenyls (PCBs), benzo[a]pyrene... approved EPA Method 525.2, Revision 2.0 for each of the 17 regulated semivolatile organic contaminants. EPA...
The Effects of Tail Docking Method on Piglets' Behavioral Responses to a Formalin Pain Test
USDA-ARS?s Scientific Manuscript database
Routine piglet production procedures, for example teeth clipping, tail docking and castration, most likely cause pain and are under increasing scrutiny from the animal rights lobby. The objectives of this study were to assess the impact of 2 alternative methods of tail-docking on subsequent response...
76 FR 70811 - Notice of Applications for Modification of Special Permit
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... the applications are available for inspection in the Records Center, East Building, PHH-30, 1200 New...; 173.301; permit to authorize an 173.304. alternative test and inspection procedure. 13350-M National... 8 hazardous materials and to add 19 new cargo tanks. 14728-M International 49 CFR 173.416(c).... To...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-21
... Total Coliform Total Coliform 9221 A, B, C..... 9221 A, B, C..... Fermentation Technique. Total Coliform... Methodology category Method SM 22nd Edition \\28\\ Total Coliforms Lactose Fermentation Standard Total 9221 B.1, B.2 Methods. Coliform Fermentation Technique. Enzyme Substrate Colilert[supreg].... 9223 B Methods...
NASA Technical Reports Server (NTRS)
Glasgow, Shaun; Kittredge, Ken
2003-01-01
A thermal interface material is one of the many tools that are often used as part of the thermal control scheme for space-based applications. These materials are placed between, for example, an avionics box and a cold plate, in order to improve the conduction heat transfer so that proper temperatures can be maintained. Historically at Marshall Space Flight Center, CHO-THERM@ 1671 has primarily been used for applications where an interface material was deemed necessary. However, there have been numerous alternatives come on the market in recent years. It was decided that a number of these materials should be tested against each other to see if there were better performing alternatives. The tests were done strictly to compare the thermal performance of the materials relative to each other under repeatable conditions and they do not take into consideration other design issues such as off-gassing, electrical conduction or isolation, etc. This paper details the materials tested, test apparatus, procedures, and results of these tests.
Inference for High-dimensional Differential Correlation Matrices *
Cai, T. Tony; Zhang, Anru
2015-01-01
Motivated by differential co-expression analysis in genomics, we consider in this paper estimation and testing of high-dimensional differential correlation matrices. An adaptive thresholding procedure is introduced and theoretical guarantees are given. Minimax rate of convergence is established and the proposed estimator is shown to be adaptively rate-optimal over collections of paired correlation matrices with approximately sparse differences. Simulation results show that the procedure significantly outperforms two other natural methods that are based on separate estimation of the individual correlation matrices. The procedure is also illustrated through an analysis of a breast cancer dataset, which provides evidence at the gene co-expression level that several genes, of which a subset has been previously verified, are associated with the breast cancer. Hypothesis testing on the differential correlation matrices is also considered. A test, which is particularly well suited for testing against sparse alternatives, is introduced. In addition, other related problems, including estimation of a single sparse correlation matrix, estimation of the differential covariance matrices, and estimation of the differential cross-correlation matrices, are also discussed. PMID:26500380
48 CFR 27.101 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... However, agencies are authorized to adopt alternative policies, procedures, solicitation provisions, and..., treaties, or international agreements. Any agency adopting alternative policies, procedures, solicitation...
NASA Astrophysics Data System (ADS)
Badini, L.; Grassi, F.; Pignari, S. A.; Spadacini, G.; Bisognin, P.; Pelissou, P.; Marra, S.
2016-05-01
This work presents a theoretical rationale for the substitution of radiated-susceptibility (RS) verifications defined in current aerospace standards with an equivalent conducted-susceptibility (CS) test procedure based on bulk current injection (BCI) up to 500 MHz. Statistics is used to overcome the lack of knowledge about uncontrolled or uncertain setup parameters, with particular reference to the common-mode impedance of equipment. The BCI test level is properly investigated so to ensure correlation of currents injected in the equipment under test via CS and RS. In particular, an over-testing probability quantifies the severity of the BCI test with respect to the RS test.
Rhebergen, Koenraad S; van Esch, Thamar E M; Dreschler, Wouter A
2015-06-01
A temporal resolution test in addition to the pure-tone audiogram may be of great clinical interest because of its relevance in speech perception and expected relevance in hearing aid fitting. Larsby and Arlinger developed an appropriate clinical test, but this test uses a Békèsy-tracking procedure for estimating masked thresholds in stationary and interrupted noise to assess release of masking (RoM) for temporal resolution. Generally the Hughson-Westlake up-down procedure is used in the clinic to measure the pure-tone thresholds in quiet. A uniform approach will facilitate clinical application and might be appropriate for RoM measurements as well. Because there is no golden standard for measuring the RoM in the clinic, we examine in the present study the Hughson-Westlake up-down procedure to measure the RoM and compare the results with the Békèsy-tracking procedure. The purpose of the current study was to examine the differences between a Békèsy-tracking procedure and the Hughson-Westlake up-down procedure for estimating masked thresholds in stationary and interrupted noise to assess RoM. RoM is assessed in eight normal-hearing (NH) and ten hearing-impaired (HI) listeners through both methods. Results from both methods are compared with each other and with predicted thresholds from a model. Wilcoxon signed-rank tests, paired t tests. Some differences between the two methods were found. We used a model to quantify the results of the two measurement procedures. The results of the Hughson-Westlake procedure were clearly better in agreement with the model than the results of the Békèsy-tracking procedure. Furthermore, the Békèsy-tracking procedure showed more spread in the results of the NH listeners than the Hughson-Westlake procedure. The Hughson-Westlake procedure seems to be an applicable alternative for measuring RoM for temporal resolution in the clinical audiological practice. American Academy of Audiology.
A hydrostatic stress-dependent anisotropic model of viscoplasticity
NASA Technical Reports Server (NTRS)
Robinson, D. N.; Tao, Q.; Verrilli, M. J.
1994-01-01
A hydrostatic stress-dependent, anisotropic model of viscoplasticity is formulated as an extension of Bodner's model. This represents a further extension of the isotropic Bodner model over that made to anisotropy by Robinson and MitiKavuma. Account is made of the inelastic deformation that can occur in metallic composites under hydrostatic stress. A procedure for determining the material parameters is identified that is virtually identical to the established characterization procedure for the original Bodner model. Characterization can be achieved using longitudinal/transverse tensile and shear tests and hydrostatic stress tests; alternatively, four off-axis tensile tests can be used. Conditions for a yield stress minimum under off-axis tension are discussed. The model is applied to a W/Cu composite; characterization is made using off-axis tensile data generated at NASA Lewis Research Center (LeRC).
Theoretical considerations of some nonlinear aspects of hypersonic panel flutter
NASA Technical Reports Server (NTRS)
Mcintosh, S. C., Jr.
1974-01-01
A research project to analyze the effects of hypersonic nonlinear aerodynamic loading on panel flutter is reported. The test equipment and procedures for conducting the tests are explained. The effects of aerodynamic linearities on stability were evaluated by determining constant-initial-energy amplitude-sensitive stability boundaries and comparing them with the corresponding linear stability boundaries. An attempt to develop an alternative method of analysis for systems where amplitude-sensitive instability is possible is presented.
Guilbaud, Olivier
2011-11-01
In their review of challenges to multiple testing in clinical trials, Hung and Wang (2010) considered the situation where a treatment is to be compared with an active comparator and the aim is to show non-inferiority and (if possible) superiority with respect to a primary and a secondary endpoint. This note extends their discussion of this particular situation, taking the sequentially rejective procedure they used for illustration as a starting point. Some alternative multiple testing procedures (MTPs) are considered, and corresponding simultaneous confidence regions are discussed that provide additional information "for free". The choice may then be based on the properties of these MTPs and corresponding confidence regions. 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
40 CFR 85.2114 - Basis of certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... an alternative, the aftermarket part manufacturer may use a different durability procedure if it can..., appendix IV. As an alternative, the aftermarket part manufacturer may use a different durability procedure..., appendix IV can be used. As an alternative, the aftermarket part manufacturer may use a different...
1988-03-01
INDUSTRY ANALYSIS/FINDINGS 132 12 EQUIPMENT/MACHINERY ALTERNATIVES 134 13 MIS REQUIREMENTS/IMPROVEMENTS 135 14 COST BENEFIT ANALYSIS AND PROCEDURE 137 15...SOFTWARE DIAGRAM 14.0-1 COST BENEFIT ANALYSIS METHODOLOGY 138 14.3-1 PROJECT 80 EXPENDITURE SCHEDULE 141 14.4-1 PROJECT 80 CASH FLOWS 142 15.1-1 PROJECT 80...testing, streamlining work flow, and installation of ergonomically designed work cell/work centers. The benefits associated with the implementation of ITM
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2011 CFR
2011-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
Code of Federal Regulations, 2010 CFR
2010-07-01
... either total organic HAP or TOC. For purposes of this paragraph (c), the term “batch emission episode... ensure the measurement of total organic HAP or TOC (minus methane and ethane) concentrations in all batch... organic HAP or TOC, as appropriate. Alternatively, any other method or data that has been validated...
Foreign Language Curricula in Japanese High Schools: A Case Study in Miyagi Prefecture
ERIC Educational Resources Information Center
Ball, Daniel
2007-01-01
The purpose of this study was to examine the foreign language curricula in Japanese high schools for the purpose of gaining insight into alternative views of foreign language education. Teachers, administrators, and staff at two high schools in Miyagi Prefecture were interviewed. Teachers were asked about testing, placement procedures, standards,…
Rispin, Amy; Farrar, David; Margosches, Elizabeth; Gupta, Kailash; Stitzel, Katherine; Carr, Gregory; Greene, Michael; Meyer, William; McCall, Deborah
2002-01-01
The authors have developed an improved version of the up-and-down procedure (UDP) as one of the replacements for the traditional acute oral toxicity test formerly used by the Organisation for Economic Co-operation and Development member nations to characterize industrial chemicals, pesticides, and their mixtures. This method improves the performance of acute testing for applications that use the median lethal dose (classic LD50) test while achieving significant reductions in animal use. It uses sequential dosing, together with sophisticated computer-assisted computational methods during the execution and calculation phases of the test. Staircase design, a form of sequential test design, can be applied to acute toxicity testing with its binary experimental endpoints (yes/no outcomes). The improved UDP provides a point estimate of the LD50 and approximate confidence intervals in addition to observed toxic signs for the substance tested. It does not provide information about the dose-response curve. Computer simulation was used to test performance of the UDP without the need for additional laboratory validation.
Musellec, H; Bernard, F; Houssel, P; Guillou, N; Hugot, P; Martin, L; Hamelin, H; Lanchou, J; Gentili, M-E; Devins, C; Virot, C
2010-12-01
implant placement Essure, sterilization procedure for women, were performed under hypnosedation (HYP) and compared to the operative anxiety and analgesia of 12 patients operated-on under general anesthesia (GA). prospective and comparative group study. two groups of twelve patients were matched and compared based on the choice of anesthetic technique: hypnotics (HYP) with possible additional sedation by propofol and remifentanil or GA involving propofol, sevoflurane and remifentanil. The assessment of anxiety and pain based on a visual analogy scale (0-10) and use of analgesics were studied in the recovery room and at discharge of hospital. The statistical analysis relies on nonparametric tests for paired data (Wilcoxon test). all patients were operated. The two groups are statistically comparable. The preoperative anxiety before premedication is lower in the HYP group (p<0.05). No conversion to general anaesthesia is necessary in the HYP group, but five patients were using sedatives drugs but doses are very low compared to general anaesthesia. The analgesic consumption was equivalent in both groups. we conclude that hypnosedation is a valuable alternative to traditional anesthetic techniques for ambulatory Essure implant. The use of hypnotic tool is an interesting alternative for the management of patients during invasive medical procedures or surgical, providing psychological benefits to the patient. 2010. Published by Elsevier SAS.
Eglit, Graham M L; Lynch, Julie K; McCaffrey, Robert J
2017-03-01
The Test of Memory Malingering (TOMM) and the Word Memory Test (WMT) are both performance validity tests (PVTs) that use a two-alternative forced-choice (2AFC) recognition memory format. Several studies have reported that these tests are susceptible to cognitive impairment and that the WMT is more susceptible than the TOMM. The current study explored components of recognition memory (i.e., conscious recollection and familiarity) underlying the TOMM and WMT to identify factors that make them susceptible and resilient to cognitive impairment. Fifty-four nonclinical undergraduate research participants were administered the TOMM and WMT while providing introspective judgments about their recognition memory using the remember/know/guess procedure. In addition, half of participants were administered dual-task interference, a manipulation intended to reduce recollection, during these tests, while the other half completed these tests without interference. Standard cutoffs on the TOMM and WMT were explored, as well as alternative cutoffs based on TOMM Trial 1 scores. The WMT was more impacted by dual-task interference than standard TOMM cutoff trials, while alternative TOMM cutoff trials were equally impacted by dual-task interference relative to the WMT. Dual-task interference reduced recollection on these tests, but spared familiarity. Standard TOMM trials and the WMT were relatively comparable on levels of recollection, but familiarity contributed more to the TOMM than to the WMT. Alternative TOMM trials possessed lower familiarity and recollection than standard TOMM trials and lower recollection than the WMT. Reduced recollection places examinees at risk of failing the TOMM and WMT, while familiarity contributes to the relative resilience of the standard TOMM. Future development of 2AFC recognition memory PVTs should attempt to maximize the contribution of familiarity to their completion.
Effects on locomotion and memory in 2 models of cerebral hypoperfusion in male Wistar rats.
Martínez-Díaz, J A; García, L I; Hernández, M E; Aranda-Abreu, G E
2015-09-01
Cerebral ischaemia is one of the most common neurological diseases worldwide. Its many sequelae range from motor and sensory symptoms to cognitive decline and dementia. Animal models of cerebral ischaemia/hypoperfusion elicit effects on long term memory; however, the effects of these procedures on short term memory are not clearly understood and effects induced by alternative hypoperfusion models are completely unknown. We evaluated the effects of 2 cerebral hyperperfusion models on memory in 3-month-old male rats. Episodic memory and working memory were assessed using the new object recognition test and the spontaneous alteration test, respectively. Neurological assessment was also performed, along with an open field test to evaluate locomotor activity. Rats in both hyperperfusion models displayed no cognitive changes. Rats with unilateral left-sided ligation plus temporary ligation of the right carotid tended to show slightly impaired performance on the new object recognition test on the second day after the procedure. In contrast, the group with permanent unilateral ligation tended to display alterations in working and episodic memory 9 days after the procedure, but they subsequently recovered. Despite these differences, both hypoperfusion groups displayed clear signs of motor impairment 2 days after the procedure, as reflected by their decreased locomotor activity during the open field test. Copyright © 2014 Sociedad Española de Neurología. Published by Elsevier España, S.L.U. All rights reserved.
14 CFR Special Federal Aviation... - Alternative Communications and Dispatching Procedures
Code of Federal Regulations, 2010 CFR
2010-01-01
... Procedures Federal Special Federal Aviation Regulation 80 Aeronautics and Space FEDERAL AVIATION... No. 80 Special Federal Aviation Regulation 80—Alternative Communications and Dispatching Procedures 1. Applicability. This Special Federal Aviation Regulation applies to each holder of an air carrier or operating...
14 CFR Special Federal Aviation... - Alternative Communications and Dispatching Procedures
Code of Federal Regulations, 2011 CFR
2011-01-01
... Procedures Federal Special Federal Aviation Regulation 80 Aeronautics and Space FEDERAL AVIATION... No. 80 Special Federal Aviation Regulation 80—Alternative Communications and Dispatching Procedures 1. Applicability. This Special Federal Aviation Regulation applies to each holder of an air carrier or operating...
Advanced Lockouts: Reengineering Safety Programs for Efficiency.
Michalscheck, Jimi
2015-08-01
Remember one golden rule when engineering out lockout/tagout: No additional risk can be introduced to the employees by using alternative procedures. If you can design alternative procedures and an overall alternative program to ensure equivalent protection for specific tasks...the sky is the limit to enhancing productivity.
46 CFR 115.645 - Alternative Hull Examination (AHE) Procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alternative Hull Examination (AHE) Procedure. 115.645... AND CERTIFICATION Hull and Tailshaft Examinations § 115.645 Alternative Hull Examination (AHE... underwater hull plating and a detailed examination of all hull welds, propellers, tailshafts, rudders, and...
Oral acute toxic class method: a successful alternative to the oral LD50 test.
Schlede, Eva; Genschow, Elke; Spielmann, Horst; Stropp, Gisela; Kayser, Detlev
2005-06-01
The oral acute toxic class method (ATC method) was developed as an alternative to replace the oral LD50 test. The ATC method is a sequential testing procedure using only three animals of one sex per step at any of the defined dose levels. Depending on the mortality rate three but never more than six animals are used per dose level. This approach results in the reduction of numbers of animals used in comparison to the LD50 test by 40-70%. The principle of the oral ATC method is based on the Probit model and it was first evaluated on a biometric basis before a national and subsequently an international ring study were conducted. The results demonstrated an excellent agreement between the toxicity and the animal numbers predicted biometrically and observed in the validation studies. The oral ATC method was adopted as an official test guideline by OECD in 1996 and was slightly amended in 2001. The ATC method has been successfully used in Germany and in 2003 >85% of all tests on acute oral toxicity testing was conducted as oral ATC tests. In member states of the European Union the ATC method is used in the range of 50% of all tests conducted. Meanwhile the oral LD50 test has been deleted by OECD, by the European Union and by the USA, making the use of alternatives to the oral LD50 test mandatory.
Alternatives to animal experimentation in basic research.
Gruber, Franz P; Hartung, Thomas
2004-01-01
In contrast to animal testing required by law to guarantee minimum safety standards for the licensing of drugs and chemicals, there are no regulations in basic research forcing scientists to perform animal tests. By (usually) free choice, questions are posed and hypotheses are examined which, in many cases, can only be answered by means of animal tests. Just as easily, different questions could be asked or different hypotheses could be examined which do not require animal tests. The only criterion for the choice of a topic is its relevance which cannot necessarily be judged in the short-term. Thus, it is up to the individual scientist to judge what is worth studying and therefore worth animal consumption. The educated mind will consider ethical aspects of this choice. However, on the other hand, this decision is largely influenced by questions of efficacy or (in a negative sense) by the obstacles posed to an animal consuming approach. Here, peer review and general attitude will strongly influence the methodology chosen. Availability and awareness of adequate in vitro techniques represent the prerequisites for the use of alternative methods. The least one can do in basic research is to avoid tests which cause severe suffering to animals, as is required in Switzerland and other European countries by binding ethical principles and guidelines. The increasing standard of approval and control procedures has improved the situation over the years. There are many examples of successful alternative methods in basic research. But, the application of such methods is in most cases limited to the laboratories in which they were developed, calling for technology transfer. Exceptions are procedures that are used worldwide, like the production of monoclonal antibodies, which instead of using the ascites mouse can also be performed in vitro with some good will. In these cases, commercialisation of the techniques has aided their spread within the scientific community. Sadly, many methods, even if published in the scientific literature, are little standardised and reproducible. The suggestion is put forward that publicly accessible databases should make available more detailed descriptions of methodologies. Due to limitations in space, many scientific journals cannot publish detailed methodological descriptions. However, nowadays a supplementary central deposit of methods could easily be linked to the respective article. In numerous cases though, there is simply a lack of will to change procedures to methods without animal tests or to pose questions differently in order to avoid the use of animals or to reduce their number or, at least, to reduce stress. In other cases, researchers are simply not aware of the limitations of the animal experiment as such. A thorough review of the validity of critical animal experiments should be carried out and made available publicly. For example, many animal experiments are dramatically "under-powered", i.e. carried out with groups that are too small to allow conclusions to be drawn from the outcome. This stands in marked contrast to in vitro experiments where replicate experiments usually represent no major problem. Since in vitro models are generally more prone to artefacts due to the numerous variables, e.g. of cell culture, the key requirement for their application is their validation and quality control. Guided by the experience from validation studies for alternative methods in toxicology, concepts of a Good Cell Culture Practice (GCCP) are currently being developed which aim to define minimum quality standards for in vitro techniques. This initiative aiming to increase quality must be complemented by a concept to systematically assess the relevance of the tests in order to finally achieve an evidence-based biomedical research. A change in this direction is only possible if those public funds, which were previously assigned predominantly to alternatives to the animal tests required by law, are now channelled increasingly into developing those for basic research. A financial incentive is necessary to change procedures in basic research to animal free procedures. Ethical considerations alone will bring little movement or change. It is unacceptable that, while numbers of animal tests decrease in development and notification of drugs and chemicals, they are increasing in basic research. Due to the central role of publishing scientific results, the key options for control are the respective rules of journals for the acceptance of articles. By demanding certain standards in the instructions for authors, e.g. of quality (GCCP), relevance and in case of animal experiments proof that no alternative is available, pressure could be dramatically increased. It is suggested to hold a consensus conference of journals in the life sciences on this topic.
Unscaled Bayes factors for multiple hypothesis testing in microarray experiments.
Bertolino, Francesco; Cabras, Stefano; Castellanos, Maria Eugenia; Racugno, Walter
2015-12-01
Multiple hypothesis testing collects a series of techniques usually based on p-values as a summary of the available evidence from many statistical tests. In hypothesis testing, under a Bayesian perspective, the evidence for a specified hypothesis against an alternative, conditionally on data, is given by the Bayes factor. In this study, we approach multiple hypothesis testing based on both Bayes factors and p-values, regarding multiple hypothesis testing as a multiple model selection problem. To obtain the Bayes factors we assume default priors that are typically improper. In this case, the Bayes factor is usually undetermined due to the ratio of prior pseudo-constants. We show that ignoring prior pseudo-constants leads to unscaled Bayes factor which do not invalidate the inferential procedure in multiple hypothesis testing, because they are used within a comparative scheme. In fact, using partial information from the p-values, we are able to approximate the sampling null distribution of the unscaled Bayes factor and use it within Efron's multiple testing procedure. The simulation study suggests that under normal sampling model and even with small sample sizes, our approach provides false positive and false negative proportions that are less than other common multiple hypothesis testing approaches based only on p-values. The proposed procedure is illustrated in two simulation studies, and the advantages of its use are showed in the analysis of two microarray experiments. © The Author(s) 2011.
Environmental testing, official methods, and attitudes toward noncompliance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krages, B.P. II
1999-08-01
The US Environmental Protection Agency (EPA) has established longstanding regulations that prescribe the analytical procedures to be followed when parties submit information pursuant to regulatory programs. However, problems associated with unnecessary or irrational testing requirements along with the difficulty in obtaining approval of alternate procedures, has resulted in widespread noncompliance with those regulations. For the most part, agencies have tolerated this attitude of noncompliance and have in some ways contributed to it by adopting testing requirements that make little or no sense. Unfortunately, this complacency leaves agencies and regulated parties vulnerable to legal problems, such as court challenges to environmentalmore » permits. Regulatory agencies should confront the problems that have led to pervasive noncompliance and amend regulations to reflect that concerns about having useful data frequently override concerns about the national uniformity of test methods. In addition, the regulated community should be more mindful of the legal enforceability of promulgated testing requirements and affirmatively address those concerns with the promulgating agencies.« less
Aschner, Michael; Ceccatelli, Sandra; Daneshian, Mardas; Fritsche, Ellen; Hasiwa, Nina; Hartung, Thomas; Hogberg, Helena T; Leist, Marcel; Li, Abby; Mundi, William R; Padilla, Stephanie; Piersma, Aldert H; Bal-Price, Anna; Seiler, Andrea; Westerink, Remco H; Zimmer, Bastian; Lein, Pamela J
2017-01-01
There is a paucity of information concerning the developmental neurotoxicity (DNT) hazard posed by industrial and environmental chemicals. New testing approaches will most likely be based on batteries of alternative and complementary (non-animal) tests. As DNT is assumed to result from the modulation of fundamental neurodevelopmental processes (such as neuronal differentiation, precursor cell migration or neuronal network formation) by chemicals, the first generation of alternative DNT tests target these processes. The advantage of such types of assays is that they capture toxicants with multiple targets and modes-of-action. Moreover, the processes modelled by the assays can be linked to toxicity endophenotypes, i.e., alterations in neural connectivity that form the basis for neurofunctional deficits in man. The authors of this review convened in a workshop to define criteria for the selection of positive/negative controls, to prepare recommendations on their use, and to initiate the setup of a directory of reference chemicals. For initial technical optimization of tests, a set of > 50 endpoint-specific control compounds was identified. For further test development, an additional "test" set of 33 chemicals considered to act directly as bona fide DNT toxicants is proposed, and each chemical is annotated to the extent it fulfills these criteria. A tabular compilation of the original literature used to select the test set chemicals provides information on statistical procedures, and toxic/non-toxic doses (both for pups and dams). Suggestions are provided on how to use the > 100 compounds (including negative controls) compiled here to address specificity, adversity and use of alternative test systems.
2014-01-01
Background In complex large-scale experiments, in addition to simultaneously considering a large number of features, multiple hypotheses are often being tested for each feature. This leads to a problem of multi-dimensional multiple testing. For example, in gene expression studies over ordered categories (such as time-course or dose-response experiments), interest is often in testing differential expression across several categories for each gene. In this paper, we consider a framework for testing multiple sets of hypothesis, which can be applied to a wide range of problems. Results We adopt the concept of the overall false discovery rate (OFDR) for controlling false discoveries on the hypothesis set level. Based on an existing procedure for identifying differentially expressed gene sets, we discuss a general two-step hierarchical hypothesis set testing procedure, which controls the overall false discovery rate under independence across hypothesis sets. In addition, we discuss the concept of the mixed-directional false discovery rate (mdFDR), and extend the general procedure to enable directional decisions for two-sided alternatives. We applied the framework to the case of microarray time-course/dose-response experiments, and proposed three procedures for testing differential expression and making multiple directional decisions for each gene. Simulation studies confirm the control of the OFDR and mdFDR by the proposed procedures under independence and positive correlations across genes. Simulation results also show that two of our new procedures achieve higher power than previous methods. Finally, the proposed methodology is applied to a microarray dose-response study, to identify 17 β-estradiol sensitive genes in breast cancer cells that are induced at low concentrations. Conclusions The framework we discuss provides a platform for multiple testing procedures covering situations involving two (or potentially more) sources of multiplicity. The framework is easy to use and adaptable to various practical settings that frequently occur in large-scale experiments. Procedures generated from the framework are shown to maintain control of the OFDR and mdFDR, quantities that are especially relevant in the case of multiple hypothesis set testing. The procedures work well in both simulations and real datasets, and are shown to have better power than existing methods. PMID:24731138
Imaging findings in essure related complications.
Djeffal, Hachem; Blouet, Marie; Pizzoferrato, Anne-Cécile; Vardon, Delphine; Belloy, Frederique; Pelage, Jean-Pierre
2018-06-21
Tubal sterilization with Essure inserts has become a prevalent alternative to laparoscopic sterilization because of its minimal invasiveness. It is a well-tolerated ambulatory procedure that provides reliable permanent contraception without the risks associated with laparoscopic surgery and general anesthesia. Correct positioning of the Essure device is necessary to achieve the fibrotic reaction induced by the polyethylene terephthalate fibers, subsequently resulting in tubal occlusion usually within 3 months. After uneventful procedures with satisfactory bilateral placement, only the correct position of the devices needs to be confirmed at follow-up. The imaging techniques used to asses Essure devices may vary depending on the country and its recommendations. The gold standard test to ascertain tubal occlusion remains the hysterosalpingography but after uneventful procedures, vaginal-ultrasound proved to be a reliable alternative to confirm the proper position of the inserts. Radiologists have been increasingly confronted to post procedural evaluations and despite the efficiency rate of the Essure device, its use still exposes to a low risk of complications and malfunctions such as unwanted pregnancies, device misplacement, tubal or uterine perforation, and chronic pelvic pain. Unintended pregnancies are mostly due to patient or physician non-compliance and misinterpretation of post procedural examinations by radiologists which emphasizes the importance of their training in Essure device assessment. This pictorial review discusses the imaging methods used to asses Essure implants and illustrates the possible complications related to them.
NASA Astrophysics Data System (ADS)
Wilcoski, James; Fischer, Chad; Allison, Tim; Malach, Kelly Jo
2002-04-01
Shear panels are used in light wood construction to resist lateral loads resulting from earthquakes or strong winds. These panels are typically made of wooden sheathing nailed to building frame members, but this standard panel design interferes with the installation of sheet insulation. A non-insulated shear panel conducts heat between the building interior and exterior wasting considerable amounts of energy. Several alternative shear panel designs were developed to avoid this insulation-mounting problem and sample panels were tested according to standard cyclic test protocols. One of the alternative designs consisted of diagonal steel straps nailed directly to the structural framing. Several others consisted of sheathing nailed to 2 x 4 framing then set into a larger 2 x 6 structural frame in such a way that no sheathing protruded beyond the edge of the 2 x 6 members. Also samples of industry-standard shear panels were constructed and tested in order to establish a performance baseline. Analytical models were developed to size test panels and predict panel behavior. A procedure was developed for establishing design capacities based on both test data and established baseline panel design capacity. The behavior of each panel configuration is documented and recommended design capacities are presented.
DOT National Transportation Integrated Search
2011-10-01
Criteria and procedures have been developed for assessing crashworthiness and occupant protection performance of alternatively designed trainsets to be used in Tier I (not exceeding 125 mph) passenger service. These criteria and procedures take advan...
Conditional Versus Unconditional Procedures for Sample-Free Item Analysis
ERIC Educational Resources Information Center
Wright, Benjamin D.; Douglas, Graham A.
1977-01-01
Procedures for the Rasch model, sample free item calibration are reviewed and compared for accuracy. The theoretically ideal procedure is shown to have practical limitations. Two alternatives to the ideal are presented and discussed. A correction for bias in the most widely used alternative is presented. (Author/JKS)
50 CFR 300.206 - Alternative procedures for IUU fishing activities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 11 2012-10-01 2012-10-01 false Alternative procedures for IUU fishing activities. 300.206 Section 300.206 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES... for IUU fishing activities. (a) These certification procedures may be applied to fish or fish products...
40 CFR 63.1113 - Procedures for approval of alternative means of emission limitation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Procedures for approval of alternative means of emission limitation. 63.1113 Section 63.1113 Protection of Environment ENVIRONMENTAL PROTECTION... Categories: Generic Maximum Achievable Control Technology Standards § 63.1113 Procedures for approval of...
Dudoit, Sandrine; Gilbert, Houston N.; van der Laan, Mark J.
2014-01-01
Summary This article proposes resampling-based empirical Bayes multiple testing procedures for controlling a broad class of Type I error rates, defined as generalized tail probability (gTP) error rates, gTP(q, g) = Pr(g(Vn, Sn) > q), and generalized expected value (gEV) error rates, gEV(g) = E[g(Vn, Sn)], for arbitrary functions g(Vn, Sn) of the numbers of false positives Vn and true positives Sn. Of particular interest are error rates based on the proportion g(Vn, Sn) = Vn/(Vn + Sn) of Type I errors among the rejected hypotheses, such as the false discovery rate (FDR), FDR = E[Vn/(Vn + Sn)]. The proposed procedures offer several advantages over existing methods. They provide Type I error control for general data generating distributions, with arbitrary dependence structures among variables. Gains in power are achieved by deriving rejection regions based on guessed sets of true null hypotheses and null test statistics randomly sampled from joint distributions that account for the dependence structure of the data. The Type I error and power properties of an FDR-controlling version of the resampling-based empirical Bayes approach are investigated and compared to those of widely-used FDR-controlling linear step-up procedures in a simulation study. The Type I error and power trade-off achieved by the empirical Bayes procedures under a variety of testing scenarios allows this approach to be competitive with or outperform the Storey and Tibshirani (2003) linear step-up procedure, as an alternative to the classical Benjamini and Hochberg (1995) procedure. PMID:18932138
Survey of practices and perceptions regarding feline onychectomy among private practitioners.
Ruch-Gallie, Rebecca; Hellyer, Peter W; Schoenfeld-Tacher, Regina; Kogan, Lori R
2016-08-01
OBJECTIVE To estimate the proportion of veterinarians working with feline patients in private practices who do or do not perform onychectomy and assess attitudes regarding and practices related to onychectomy in a large population of veterinary practitioners. DESIGN Anonymous online survey. SAMPLE 3,441 veterinarians. PROCEDURES An online survey was provided to members of the Veterinary Information Network from June 18, 2014, through July 9, 2014. Descriptive statistics and frequency distributions for applicable response types were calculated, and Mann-Whitney U tests were conducted to compare responses to onychectomy-related opinion questions between respondents who indicated they did or did not perform the procedure. Not all respondents answered every question. RESULTS 2,503 of 3,441 (72.7%) survey respondents reported performing onychectomy, and 827 (24.0%) indicated they did not; 1,534 of 2,498 (61.4%) performing the procedure reported a frequency of < 1 onychectomy/month. Most (2,256/3,023 [74.6%]) respondents who performed onychectomy indicated that they recommended nonsurgical alternatives. Surgical techniques and approaches to analgesia varied, with use of a scalpel only (1,046/1,722 [60.7%]) and perioperative administration of injectable opioids (1,933/2,482 [77.9%]) most commonly reported. Responses to opinion questions in regard to the degree of pain associated with onychectomy and recovery; whether declawing is a form of mutilation, is necessary in some cats for behavioral reasons, or is a necessary alternative to euthanasia in some cats; and whether state organizations should support a legislative ban on onychectomy differed significantly between respondents who did and did not perform the procedure. CONCLUSIONS AND CLINICAL RELEVANCE Onychectomy is a controversial topic, and this was reflected in survey results. In this sample, most veterinarians performing the procedure reported that they did so infrequently, and most offered nonsurgical alternatives to the procedure.
Does RAIM with Correct Exclusion Produce Unbiased Positions?
Teunissen, Peter J. G.; Imparato, Davide; Tiberius, Christian C. J. M.
2017-01-01
As the navigation solution of exclusion-based RAIM follows from a combination of least-squares estimation and a statistically based exclusion-process, the computation of the integrity of the navigation solution has to take the propagated uncertainty of the combined estimation-testing procedure into account. In this contribution, we analyse, theoretically as well as empirically, the effect that this combination has on the first statistical moment, i.e., the mean, of the computed navigation solution. It will be shown, although statistical testing is intended to remove biases from the data, that biases will always remain under the alternative hypothesis, even when the correct alternative hypothesis is properly identified. The a posteriori exclusion of a biased satellite range from the position solution will therefore never remove the bias in the position solution completely. PMID:28672862
Krypotos, Angelos-Miltiadis; Klugkist, Irene; Engelhard, Iris M.
2017-01-01
ABSTRACT Threat conditioning procedures have allowed the experimental investigation of the pathogenesis of Post-Traumatic Stress Disorder. The findings of these procedures have also provided stable foundations for the development of relevant intervention programs (e.g. exposure therapy). Statistical inference of threat conditioning procedures is commonly based on p-values and Null Hypothesis Significance Testing (NHST). Nowadays, however, there is a growing concern about this statistical approach, as many scientists point to the various limitations of p-values and NHST. As an alternative, the use of Bayes factors and Bayesian hypothesis testing has been suggested. In this article, we apply this statistical approach to threat conditioning data. In order to enable the easy computation of Bayes factors for threat conditioning data we present a new R package named condir, which can be used either via the R console or via a Shiny application. This article provides both a non-technical introduction to Bayesian analysis for researchers using the threat conditioning paradigm, and the necessary tools for computing Bayes factors easily. PMID:29038683
Accomplishments in free-piston stirling tests at NASA GRC
NASA Astrophysics Data System (ADS)
Schreiber, Jeffrey G.; Skupinski, Robert C.
2002-01-01
A power system based on the Stirling Radioisotope Generator (SRG) has been identified for potential use on deep space missions, as well as for Mars rovers that may benefit from extended operation. The Department of Energy (DOE) has responsibility for developing the generator and the NASA Glenn Research Center (GRC) is supporting DOE in this effort. The generator is based on a free-piston Stirling power convertor that has been developed by the Stirling Technology Company (STC) under contract to DOE. The generator would be used as a high-efficiency alternative to the Radioisotope Thermoelectric Generators (RTGs) that have been used on many previous missions. The increased efficiency leads to a factor of 3 to 4 reduction in the inventory of plutonium required to heat the generator. GRC has been involved in the development of Stirling power conversion technology for over 25 years. The support provided to this project by GRC has many facets and draws upon the lab's scientists and engineers that have gained experience in applying their skills to the previous Stirling projects. This has created a staff with an understanding of the subtleties involved in applying their expertise to Stirling systems. Areas include materials, structures, tribology, controls, electromagnetic interference, permanent magnets, alternator analysis, structural dynamics, and cycle performance. One of the key areas of support to the project is in the performance testing of the free-piston Stirling convertors. Since these power convertors are the smallest, lowest power Stirling machines that have been tested at GRC, a new laboratory was equipped for this project. Procedures and test plans have been created, instrumentation and data systems developed, and Stirling convertors have been tested. This paper will describe the GRC test facility, the test procedures that are used, present some of the test results and outline plans for the future. .
Goeree, Ron; Blackhouse, Gord; Bowen, James M; O'Reilly, Daria; Sutherland, Simone; Hopkins, Robert; Chow, Benjamin; Freeman, Michael; Provost, Yves; Dennie, Carole; Cohen, Eric; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan; Paul, Narinder; Parker, John D
2013-10-01
Conventional coronary angiography (CCA) is the standard diagnostic for coronary artery disease (CAD), but multi-detector computed tomography coronary angiography (CTCA) is a non-invasive alternative. A multi-center coverage with evidence development study was undertaken and combined with an economic model to estimate the cost-effectiveness of CTCA followed by CCA vs CCA alone. Alternative assumptions were tested in patient scenario and sensitivity analyses. CCA was found to dominate CTCA, however, CTCA was relatively more cost-effective in females, in advancing age, in patients with lower pre-test probabilities of CAD, the higher the sensitivity of CTCA and the lower the probability of undergoing a confirmatory CCA following a positive CTCA. RESULTS were very sensitive to alternative patient populations and modeling assumptions. Careful consideration of patient characteristics, procedures to improve the diagnostic yield of CTCA and selective use of CCA following CTCA will impact whether CTCA is cost-effective or dominates CCA.
A rule-based software test data generator
NASA Technical Reports Server (NTRS)
Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II
1991-01-01
Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.
Aschner, Michael; Ceccatelli, Sandra; Daneshian, Mardas; Fritsche, Ellen; Hasiwa, Nina; Hartung, Thomas; Hogberg, Helena T.; Leist, Marcel; Li, Abby; Mundy, William R.; Padilla, Stephanie; Piersma, Aldert H.; Bal-Price, Anna; Seiler, Andrea; Westerink, Remco H.; Zimmer, Bastian; Lein, Pamela J.
2016-01-01
Summary There is a paucity of information concerning the developmental neurotoxicity (DNT) hazard posed by industrial and environmental chemicals. New testing approaches will most likely be based on batteries of alternative and complementary (non-animal) tests. As DNT is assumed to result from the modulation of fundamental neurodevelopmental processes (such as neuronal differentiation, precursor cell migration or neuronal network formation) by chemicals, the first generation of alternative DNT tests target these processes. The advantage of such types of assays is that they capture toxicants with multiple targets and modes-of-action. Moreover, the processes modelled by the assays can be linked to toxicity endophenotypes, i.e. alterations in neural connectivity that form the basis for neurofunctional deficits in man. The authors of this review convened in a workshop to define criteria for the selection of positive/negative controls, to prepare recommendations on their use, and to initiate the setup of a directory of reference chemicals. For initial technical optimization of tests, a set of >50 endpoint-specific control compounds was identified. For further test development, an additional “test” set of 33 chemicals considered to act directly as bona fide DNT toxicants is proposed, and each chemical is annotated to the extent it fulfills these criteria. A tabular compilation of the original literature used to select the test set chemicals provides information on statistical procedures, and toxic/non-toxic doses (both for pups and dams). Suggestions are provided on how to use the >100 compounds (including negative controls) compiled here to address specificity, adversity and use of alternative test systems. PMID:27452664
ERIC Educational Resources Information Center
Klinger, Don A.; Rogers, W. Todd
2003-01-01
The estimation accuracy of procedures based on classical test score theory and item response theory (generalized partial credit model) were compared for examinations consisting of multiple-choice and extended-response items. Analysis of British Columbia Scholarship Examination results found an error rate of about 10 percent for both methods, with…
Code of Federal Regulations, 2010 CFR
2010-07-01
... may be based on either total organic HAP or TOC. For purposes of this paragraph (c), the term “batch... inlet sampling sites shall ensure the measurement of total organic HAP or TOC (minus methane and ethane... used to determine the concentration of organic HAP or TOC, as appropriate. Alternatively, any other...
Oxygen separation from air using zirconia solid electrolyte membranes
NASA Technical Reports Server (NTRS)
Suitor, J. W.; Marner, W. J.; Schroeder, J. E.; Losey, R. W.; Ferrall, J. F.
1988-01-01
Air separation using a zirconia solid electrolyte membrane is a possible alternative source of oxygen. The process of zirconia oxygen separation is reviewed, and an oxygen plant concept using such separation is described. Potential cell designs, stack designs, and testing procedures are examined. Fabrication of the materials used in a zirconia module as well as distribution plate design and fabrication are examined.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-20
... alternate test procedures. 10 CFR 430.27(l). Waivers remain in effect pursuant to the provisions of 10 CFR... for products that employ these long-time or variable defrost control strategies, DOE is granting GE's... representations about the energy use of its refrigerator-freezer products for compliance, marketing, or other...
40 CFR 62.14452 - What test methods and procedures must I use?
Code of Federal Regulations, 2014 CFR
2014-07-01
... flow rate and minimum scrubber liquor pH to demonstrate compliance with the HCl emissions limit. (6... Method 6 or 6C of 40 CFR part 60, appendix A-4 to measure SO2 emissions; (h) You must use EPA Reference... specified in paragraph (p) of this section, as an alternative to demonstrate compliance with the dioxin...
40 CFR 62.14452 - What test methods and procedures must I use?
Code of Federal Regulations, 2013 CFR
2013-07-01
... flow rate and minimum scrubber liquor pH to demonstrate compliance with the HCl emissions limit. (6... Method 6 or 6C of 40 CFR part 60, appendix A-4 to measure SO2 emissions; (h) You must use EPA Reference... specified in paragraph (p) of this section, as an alternative to demonstrate compliance with the dioxin...
Variation of bar-press duration: where do new responses come from?
Roberts, Seth; Gharib, Afshin
2006-06-01
Instrumental learning involves both variation and selection: variation of what the animal does, and selection by reward from among the variation. Four experiments with rats suggested a rule about how variation is controlled by recent events. Experiment 1 used the peak procedure. Measurements of bar-press durations showed a sharp increase in mean duration after the time that food was sometimes given. The increase was triggered by the omission of expected food. Our first explanation of the increase was that it was a frustration effect. Experiment 2 tested this explanation with a procedure in which the first response of a trial usually produced food, ending the trial. In Experiment 2, unlike Experiment 1, omission of expected food did not produce a large increase in bar-press duration, which cast doubt on the frustration explanation. Experiments 3 and 4 tested an alternative explanation: a decrease in expectation of reward increases variation. Both used two signals associated with different probabilities of reward. Bar presses were more variable in duration during the signal with the lower probability of reward, supporting this alternative. These experiments show how variation can be studied with ordinary equipment and responses.
15 CFR 20.18 - Alternative funds disbursal procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Alternative funds disbursal procedure. 20.18 Section 20.18 Commerce and Foreign Trade Office of the Secretary of Commerce NONDISCRIMINATION... undisbursed funds from the terminated award, make a new award to an alternate recipient, i.e. any public or...
15 CFR 20.18 - Alternative funds disbursal procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 1 2014-01-01 2014-01-01 false Alternative funds disbursal procedure. 20.18 Section 20.18 Commerce and Foreign Trade Office of the Secretary of Commerce NONDISCRIMINATION... undisbursed funds from the terminated award, make a new award to an alternate recipient, i.e. any public or...
15 CFR 20.18 - Alternative funds disbursal procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 1 2011-01-01 2011-01-01 false Alternative funds disbursal procedure. 20.18 Section 20.18 Commerce and Foreign Trade Office of the Secretary of Commerce NONDISCRIMINATION... undisbursed funds from the terminated award, make a new award to an alternate recipient, i.e. any public or...
15 CFR 20.18 - Alternative funds disbursal procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 1 2013-01-01 2013-01-01 false Alternative funds disbursal procedure. 20.18 Section 20.18 Commerce and Foreign Trade Office of the Secretary of Commerce NONDISCRIMINATION... undisbursed funds from the terminated award, make a new award to an alternate recipient, i.e. any public or...
Alternative Refractive Surgery Procedures
... alternative refractive surgery procedures to LASIK . Wavefront-Guided LASIK Before surgery, the excimer laser is programmed with ... precise "sculpting" of each unique cornea. In conventional LASIK , this programming is based on the patient's vision ...
Reasoning about procedural knowledge
NASA Technical Reports Server (NTRS)
Georgeff, M. P.
1985-01-01
A crucial aspect of automated reasoning about space operations is that knowledge of the problem domain is often procedural in nature - that is, the knowledge is often in the form of sequences of actions or procedures for achieving given goals or reacting to certain situations. In this paper a system is described that explicitly represents and reasons about procedural knowledge. The knowledge representation used is sufficiently rich to describe the effects of arbitrary sequences of tests and actions, and the inference mechanism provides a means for directly using this knowledge to reach desired operational goals. Furthermore, the representation has a declarative semantics that provides for incremental changes to the system, rich explanatory capabilities, and verifiability. The approach also provides a mechanism for reasoning about the use of this knowledge, thus enabling the system to choose effectively between alternative courses of action.
Specialty Payment Model Opportunities and Assessment
Mulcahy, Andrew W.; Chan, Chris; Hirshman, Samuel; Huckfeldt, Peter J.; Kofner, Aaron; Liu, Jodi L.; Lovejoy, Susan L.; Popescu, Ioana; Timbie, Justin W.; Hussey, Peter S.
2015-01-01
Abstract Gastroenterology and cardiology services are common and costly among Medicare beneficiaries. Episode-based payment, which aims to create incentives for high-quality, low-cost care, has been identified as a promising alternative payment model. This article describes research related to the design of episode-based payment models for ambulatory gastroenterology and cardiology services for possible testing by the Center for Medicare and Medicaid Innovation at the Centers for Medicare and Medicaid Services (CMS). The authors analyzed Medicare claims data to describe the frequency and characteristics of gastroenterology and cardiology index procedures, the practices that delivered index procedures, and the patients that received index procedures. The results of these analyses can help inform CMS decisions about the definition of episodes in an episode-based payment model; payment adjustments for service setting, multiple procedures, or other factors; and eligibility for the payment model. PMID:28083363
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodgson, Alfred T.; Fisk, William J.; Shendell, Derek G.
Relocatable classrooms (RCs) are widely employed by California school districts to satisfy rapidly expanding space requirements due to population growth and class size reduction policies. There is public concern regarding indoor environmental quality (IEQ) in schools, particularly in RCs, but very little data to support or dispel these concerns. Several studies are investigating various aspects of IEQ in California schools. This laboratory-based study focused on evaluating the emissions of toxic and/or odorous volatile organic compounds (VOCs), including formaldehyde and acetaldehyde, from materials used to finish the interiors of new RCs. Furthermore, the study implemented a procedure for VOC source reductionmore » by testing and selecting lower-emitting materials as substitutes for standard materials. In total, 17 standard and alternate floor coverings, wall panels and ceiling panels were quantitatively tested for emissions of VOCs using smallscale environmental chambers. Working with the largest northern California manufacturer of conventional RCs and two school districts, specifications were developed for four new RCs to be produced in early summer 2001. Two of these will be predominantly finished with standard materials. Alternate carpet systems, an alternate wall panel covering and an alternate ceiling panel were selected for the two other RCs based on the results of the laboratory study and considerations of cost and anticipated performance and maintenance. Particular emphasis was placed on reducing the concentrations of VOCs on California agency lists of toxic compounds. Indoor concentrations of toxic and odorous VOCs were estimated for the four classrooms by mass balance using the measured VOC emission factors, exposed surface areas of the materials in the RCs, and three ventilation rate scenarios. Results indicate that reductions in the concentrations of formaldehyde, acetaldehyde phenol, di(ethylene glycol) butyl ether, vinyl acetate, 1,2,4-trimethylbenzene and 1-methyl-2-pyrrolidinone should be achieved as the result of the source reduction procedure.« less
Efficient airport detection using region-based fully convolutional neural networks
NASA Astrophysics Data System (ADS)
Xin, Peng; Xu, Yuelei; Zhang, Xulei; Ma, Shiping; Li, Shuai; Lv, Chao
2018-04-01
This paper presents a model for airport detection using region-based fully convolutional neural networks. To achieve fast detection with high accuracy, we shared the conv layers between the region proposal procedure and the airport detection procedure and used graphics processing units (GPUs) to speed up the training and testing time. For lack of labeled data, we transferred the convolutional layers of ZF net pretrained by ImageNet to initialize the shared convolutional layers, then we retrained the model using the alternating optimization training strategy. The proposed model has been tested on an airport dataset consisting of 600 images. Experiments show that the proposed method can distinguish airports in our dataset from similar background scenes almost real-time with high accuracy, which is much better than traditional methods.
Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.
Smith, P B; Rhoden, D L; Tomfohrde, K M
1975-01-01
The PathoTec Rapid I-D System for identifying Enterobacteriaceae was evaluated with 471 cultures. In 4,910 individual test comparisons, 95.5% of the results agreed, with results of only two test strips, those for esculin hydrolysis and urease production, agreeing with conventional tests in less than 94% of the trials. The PathoTec system exhibited 94.3% accuracy in identifying these cultures in a double-blind study with conventional media and procedures as the alternate system. Two newly developed test strips, for 0-nitrophenyl-beta-D-galactopyranoside and ornithine decarboxylase, were found to be highly reliable. PMID:1041590
ERIC Educational Resources Information Center
Campo, Antonio; Rodriguez, Franklin
1998-01-01
Presents two alternative computational procedures for solving the modified Bessel equation of zero order: the Frobenius method, and the power series method coupled with a curve fit. Students in heat transfer courses can benefit from these alternative procedures; a course on ordinary differential equations is the only mathematical background that…
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 14 2011-07-01 2011-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 15 2014-07-01 2014-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 15 2013-07-01 2013-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 15 2012-07-01 2012-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
Code of Federal Regulations, 2011 CFR
2011-07-01
... alternative dispute resolution (ADR), as described in paragraph (c) of this section (5) A written Notice of... procedures the recipient adopts must provide for alternative dispute resolution (ADR). The recipient's ADR procedures must provide that: (1) The choice whether to use ADR or the customary process rests with the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... accomplished by using a 4,410-lb (2,000-kg) weight acting as a pendulum. The impact face of the weight shall be... of the pendulum will swing, or alternatively, two sets of symmetrically located cables may be used at... from the rear, followed by a load to the side on the same enclosure structure. The pendulum swinging...
Code of Federal Regulations, 2010 CFR
2010-07-01
... accomplished by using a 4,410-lb (2,000-kg) weight acting as a pendulum. The impact face of the weight shall be... of the pendulum will swing, or alternatively, two sets of symmetrically located cables may be used at... from the rear, followed by a load to the side on the same enclosure structure. The pendulum swinging...
Code of Federal Regulations, 2012 CFR
2012-07-01
... accomplished by using a 4,410-lb (2,000-kg) weight acting as a pendulum. The impact face of the weight shall be... of the pendulum will swing, or alternatively, two sets of symmetrically located cables may be used at... from the rear, followed by a load to the side on the same enclosure structure. The pendulum swinging...
Code of Federal Regulations, 2011 CFR
2011-07-01
... accomplished by using a 4,410-lb (2,000-kg) weight acting as a pendulum. The impact face of the weight shall be... of the pendulum will swing, or alternatively, two sets of symmetrically located cables may be used at... from the rear, followed by a load to the side on the same enclosure structure. The pendulum swinging...
27 CFR 46.261 - Purpose of an alternate method or procedure.
Code of Federal Regulations, 2014 CFR
2014-04-01
... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures § 46.261...
27 CFR 46.261 - Purpose of an alternate method or procedure.
Code of Federal Regulations, 2012 CFR
2012-04-01
... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures § 46.261...
27 CFR 46.261 - Purpose of an alternate method or procedure.
Code of Federal Regulations, 2013 CFR
2013-04-01
... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures § 46.261...
27 CFR 46.261 - Purpose of an alternate method or procedure.
Code of Federal Regulations, 2010 CFR
2010-04-01
... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures § 46.261...
27 CFR 46.261 - Purpose of an alternate method or procedure.
Code of Federal Regulations, 2011 CFR
2011-04-01
... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures § 46.261...
Perez-del-Pulgar, S; Lopez, M; Gensana, M; Jorquera, J I
2006-08-01
Preparations of intravenous immunoglobulins must keep functional integrity throughout the purification process. In order to assess Fc fragment functionality, the European Pharmacopoeia proposes the Test for Fc function of immunoglobulin (2.7.9), which is based on a rubella antigen of high titre. Sometimes, such antigen is difficult to obtain. In the present study, we develop the same assay using tetanus toxoid instead of rubella antigen, adapting the procedure for the use of tetanus toxoid. The comparison between rubella-based and tetanus-based assays showed that the slopes of the haemolysis curves were higher if red blood cells had been sensitised with the rubella antigen than with tetanus toxoid. Nonetheless, the tetanus-based assay gave satisfactory results and it could be a good alternative antigen target.
A Proactive Approach to Penicillin Allergy Testing in Hospitalized Patients.
Chen, Justin R; Tarver, Scott A; Alvarez, Kristin S; Tran, Trang; Khan, David A
Penicillin allergy testing is underutilized in inpatients despite its potential to immediately impact antibiotic treatment. Although most tested patients are able to tolerate penicillin, limited availability and awareness of this tool leads to the use of costly and harmful substitutes. We established an inpatient service at a large academic hospital to identify and test patients with a history of penicillin allergy with the goals of removing inaccurate diagnoses, reducing the use of beta-lactam alternatives, and educating patients and clinicians about the procedure. Eligible inpatients were flagged daily through the electronic medical record and prioritized via a specialized algorithm. A trained clinical pharmacist performed penicillin skin tests and challenges preemptively or by provider request. Clinical characteristics and antibiotic use were analyzed in tested patients. A total of 1203 applicable charts were detected by our system leading to 252 direct evaluations over 18 months. Overall, 228 subjects (90.5%) had their penicillin allergy removed. Of these, 223 were cleared via testing and 5 by discovery of prior penicillin tolerance. Among patients testing negative, 85 (38%) subsequently received beta-lactams, preventing 504 inpatient days and 648 outpatient days on alternative agents. Penicillin allergy testing using a physician-pharmacist team model effectively removes reported allergies in hospitalized patients. The electronic medical record is a valuable asset for locating and stratifying individuals who benefit most from intervention. Proactive testing substantially reduces unnecessary inpatient and outpatient use of beta-lactam alternatives that may otherwise go unaddressed. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Fukuda, David H; Smith, Abbie E; Kendall, Kristina L; Cramer, Joel T; Stout, Jeffrey R
2012-02-01
The purpose of this study was to evaluate the use of critical velocity (CV) and isoperformance curves as an alternative to the Army Physical Fitness Test (APFT) two-mile running test. Seventy-eight men and women (mean +/- SE; age: 22.1 +/- 0.34 years; VO2(MAX): 46.1 +/- 0.82 mL/kg/min) volunteered to participate in this study. A VO2(MAX) test and four treadmill running bouts to exhaustion at varying intensities were completed. The relationship between total distance and time-to-exhaustion was tracked for each exhaustive run to determine CV and anaerobic running capacity. A VO2(MAX) prediction equation (Coefficient of determination: 0.805; Standard error of the estimate: 3.2377 mL/kg/min) was developed using these variables. Isoperformance curves were constructed for men and women to correspond with two-mile run times from APFT standards. Individual CV and anaerobic running capacity values were plotted and compared to isoperformance curves for APFT 2-mile run scores. Fifty-four individuals were determined to receive passing scores from this assessment. Physiological profiles identified from this procedure can be used to assess specific aerobic or anaerobic training needs. With the use of time-to-exhaustion as opposed to a time-trial format used in the two-mile run test, pacing strategies may be limited. The combination of variables from the CV test and isoperformance curves provides an alternative to standardized time-trial testing.
Cuenca-Estrella, Manuel; Gomez-Lopez, Alicia; Alastruey-Izquierdo, Ana; Bernal-Martinez, Leticia; Cuesta, Isabel; Buitrago, Maria J.; Rodriguez-Tudela, Juan L.
2010-01-01
The commercial technique Vitek 2 system for antifungal susceptibility testing of yeast species was evaluated. A collection of 154 clinical yeast isolates, including amphotericin B- and azole-resistant organisms, was tested. Results were compared with those obtained by the reference procedures of both the CLSI and the European Committee on Antimicrobial Susceptibility Testing (EUCAST). Two other commercial techniques approved for clinical use, the Etest and the Sensititre YeastOne, were included in the comparative exercise as well. The average essential agreement (EA) between the Vitek 2 system and the reference procedures was >95%, comparable with the average EAs observed between the reference procedures and the Sensititre YeastOne and Etest. The EA values were >97% for Candida spp. and stood at 92% for Cryptococcus neoformans. Intraclass correlation coefficients (ICC) between the commercial techniques and the reference procedures were statistically significant (P < 0.01). Percentages of very major errors were 2.6% between Vitek 2 and the EUCAST technique and 1.6% between Vitek 2 and the CLSI technique. The Vitek 2 MIC results were available after 14 to 18 h of incubation for all Candida spp. (average time to reading, 15.5 h). The Vitek 2 system was shown to be a reliable technique to determine antifungal susceptibility testing of yeast species and a more rapid and easier alternative for clinical laboratories than the procedures developed by either the CLSI or EUCAST. PMID:20220169
Adjusted regression trend test for a multicenter clinical trial.
Quan, H; Capizzi, T
1999-06-01
Studies using a series of increasing doses of a compound, including a zero dose control, are often conducted to study the effect of the compound on the response of interest. For a one-way design, Tukey et al. (1985, Biometrics 41, 295-301) suggested assessing trend by examining the slopes of regression lines under arithmetic, ordinal, and arithmetic-logarithmic dose scalings. They reported the smallest p-value for the three significance tests on the three slopes for safety assessments. Capizzi et al. (1992, Biometrical Journal 34, 275-289) suggested an adjusted trend test, which adjusts the p-value using a trivariate t-distribution, the joint distribution of the three slope estimators. In this paper, we propose an adjusted regression trend test suitable for two-way designs, particularly for multicenter clinical trials. In a step-down fashion, the proposed trend test can be applied to a multicenter clinical trial to compare each dose with the control. This sequential procedure is a closed testing procedure for a trend alternative. Therefore, it adjusts p-values and maintains experimentwise error rate. Simulation results show that the step-down trend test is overall more powerful than a step-down least significant difference test.
Mulcahy, Andrew W; Chan, Chris; Hirshman, Samuel; Huckfeldt, Peter J; Kofner, Aaron; Liu, Jodi L; Lovejoy, Susan L; Popescu, Ioana; Timbie, Justin W; Hussey, Peter S
2015-07-15
Gastroenterology and cardiology services are common and costly among Medicare beneficiaries. Episode-based payment, which aims to create incentives for high-quality, low-cost care, has been identified as a promising alternative payment model. This article describes research related to the design of episode-based payment models for ambulatory gastroenterology and cardiology services for possible testing by the Center for Medicare and Medicaid Innovation at the Centers for Medicare and Medicaid Services (CMS). The authors analyzed Medicare claims data to describe the frequency and characteristics of gastroenterology and cardiology index procedures, the practices that delivered index procedures, and the patients that received index procedures. The results of these analyses can help inform CMS decisions about the definition of episodes in an episode-based payment model; payment adjustments for service setting, multiple procedures, or other factors; and eligibility for the payment model.
Muth-Köhne, Elke; Wichmann, Arne; Delov, Vera; Fenske, Martina
2012-07-01
Rodents are widely used to test the developmental neurotoxicity potential of chemical substances. The regulatory test procedures are elaborate and the requirement of numerous animals is ethically disputable. Therefore, non-animal alternatives are highly desirable, but appropriate test systems that meet regulatory demands are not yet available. Hence, we have developed a new developmental neurotoxicity assay based on specific whole-mount immunostainings of primary and secondary motor neurons (using the monoclonal antibodies znp1 and zn8) in zebrafish embryos. By classifying the motor neuron defects, we evaluated the severity of the neurotoxic damage to individual primary and secondary motor neurons caused by chemical exposure and determined the corresponding effect concentration values (EC₅₀). In a proof-of-principle study, we investigated the effects of three model compounds thiocyclam, cartap and disulfiram, which show some neurotoxicity-indicating effects in vertebrates, and the positive controls ethanol and nicotine and the negative controls 3,4-dichloroaniline (3,4-DCA) and triclosan. As a quantitative measure of the neurotoxic potential of the test compounds, we calculated the ratios of the EC₅₀ values for motor neuron defects and the cumulative malformations, as determined in a zebrafish embryo toxicity test (zFET). Based on this index, disulfiram was classified as the most potent and thiocyclam as the least potent developmental neurotoxin. The index also confirmed the control compounds as positive and negative neurotoxicants. Our findings demonstrate that this index can be used to reliably distinguish between neurotoxic and non-neurotoxic chemicals and provide a sound estimate for the neurodevelopmental hazard potential of a chemical. The demonstrated method can be a feasible approach to reduce the number of animals used in developmental neurotoxicity evaluation procedures. Copyright © 2012 Elsevier Inc. All rights reserved.
Alternative court procedures for DUI offenders.
DOT National Transportation Integrated Search
1978-01-01
The purpose of this report is to evaluate the need for alternative court procedures in Virginia for handling cases involving persons charged with driving under the influence of alcohol (DUI), with particular focus on the referral of DUI offenders to ...
Alternatives for Assessing the Presence of Advanced Intellectual Abilities in Young Children.
ERIC Educational Resources Information Center
White, C. Stephen
1985-01-01
Assessment procedures aimed at differentiating intellectually gifted young children from their nongifted peers are proposed as alternatives to traditional identification procedures. Suggested is measuring the use of strategic behavior to solve novel problems. (Author/CL)
Low molecular-weight phenols in Tannat wines made by alternative winemaking procedures.
Favre, Guzmán; Peña-Neira, Álvaro; Baldi, Cecilia; Hernández, Natalia; Traverso, Sofía; Gil, Graciela; González-Neves, Gustavo
2014-09-01
Low molecular weight phenols of Tannat red wines produced by Traditional Maceration (TM), Prefermentative Cold Maceration (PCM), Maceration Enzyme (ENZ) and grape-Seed Tannins additions (ST), were performed and discussed. Alternatives to TM increased wine phenolic contents but unequally, ST increased mainly smaller flavans-3-ol, PCM anthocyanins and ENZ proanthocyanidins (up to 2250 mg/L). However low molecular weight flavan-3-ols remained below 9 mg/L in all wines, showing that there is not necessarily a correspondence between wine richness in total tannins and flavan-3-ols contents at low molecular weight. PCM wines had particularly high concentrations of tyrosol and tryptophol, yeast metabolism derived compounds. The use of grape-seed enological tannins did not increase grape seed derived phenolic compounds such as gallic acid. Caftaric acid was found in concentrations much higher than those reported in other grape varieties. Wine phenolic content and composition was considerably affected by the winemaking procedures tested. Copyright © 2014 Elsevier Ltd. All rights reserved.
Wisaijohn, Thunthita; Pimkhaokham, Atiphan; Lapying, Phenkhae; Itthichaisri, Chumpot; Pannarunothai, Supasit; Igarashi, Isao; Kawabuchi, Koichi
2010-01-01
This study aimed to develop a new casemix classification system as an alternative method for the budget allocation of oral healthcare service (OHCS). Initially, the International Statistical of Diseases and Related Health Problem, 10th revision, Thai Modification (ICD-10-TM) related to OHCS was used for developing the software “Grouper”. This model was designed to allow the translation of dental procedures into eight-digit codes. Multiple regression analysis was used to analyze the relationship between the factors used for developing the model and the resource consumption. Furthermore, the coefficient of variance, reduction in variance, and relative weight (RW) were applied to test the validity. The results demonstrated that 1,624 OHCS classifications, according to the diagnoses and the procedures performed, showed high homogeneity within groups and heterogeneity between groups. Moreover, the RW of the OHCS could be used to predict and control the production costs. In conclusion, this new OHCS casemix classification has a potential use in a global decision making. PMID:20936134
Wisaijohn, Thunthita; Pimkhaokham, Atiphan; Lapying, Phenkhae; Itthichaisri, Chumpot; Pannarunothai, Supasit; Igarashi, Isao; Kawabuchi, Koichi
2010-01-01
This study aimed to develop a new casemix classification system as an alternative method for the budget allocation of oral healthcare service (OHCS). Initially, the International Statistical of Diseases and Related Health Problem, 10th revision, Thai Modification (ICD-10-TM) related to OHCS was used for developing the software "Grouper". This model was designed to allow the translation of dental procedures into eight-digit codes. Multiple regression analysis was used to analyze the relationship between the factors used for developing the model and the resource consumption. Furthermore, the coefficient of variance, reduction in variance, and relative weight (RW) were applied to test the validity. The results demonstrated that 1,624 OHCS classifications, according to the diagnoses and the procedures performed, showed high homogeneity within groups and heterogeneity between groups. Moreover, the RW of the OHCS could be used to predict and control the production costs. In conclusion, this new OHCS casemix classification has a potential use in a global decision making.
Interagency comparison of iodometric methods for ozone determination
NASA Technical Reports Server (NTRS)
Demore, W. B.; Romanovsky, J. C.; Feldstein, M.; Mueller, P. K.; Hamming, W. J.
1976-01-01
The California Air Resources Board appointed an Oxidant Calibration Committee for the purpose of evaluating the accuracy of the different agency calibration procedures. The committee chose UV absorption photometry as the reference method for ozone measurement. Interagency comparisons of the various iodometric methods were conducted relative to the ultraviolet standard. The tests included versions of the iodometric methods as employed by the Air Resources Board, the Los Angeles Air Pollution Control District, and the EPA. An alternative candidate reference method for ozone measurement, gas phase titration, was also included in the test series.
NASA Technical Reports Server (NTRS)
Johnson, Kenneth L.; White, K. Preston, Jr.
2012-01-01
The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.
The use of piezosurgery in cranial surgery in children.
Ramieri, Valerio; Saponaro, Gianmarco; Lenzi, Jacopo; Caporlingua, Federico; Polimeni, Antonella; Silvestri, Alessandro; Pizzuti, Antonio; Roggini, Mario; Tarani, Luigi; Papoff, Paola; Giancotti, Antonella; Castori, Marco; Manganaro, Lucia; Cascone, Piero; Piero, Cascone
2015-05-01
Piezosurgery is an alternative surgical technique, now widely tested, that uses ultrasounds for bone cutting. This device uses ultrasounds to section hard tissues without harming surrounding soft tissues. The authors analyzed their experience in craniomaxillofacial procedures with piezosurgery. A comparison between operation timing and complication rates between piezosurgery and traditional cutting instruments has been performed. A total of 27 patients were examined (15 females and 12 males; average age, of 5.5 months) affected by craniosynostosis. The aim of this study was to analyze the advantages and disadvantages of piezosurgery in pediatric craniofacial procedures. Piezoelectric device in this study has shown being a valid instrument for bone cutting in accurate procedures, because it allows performing a more precise and safer cutting, without the risk of harming surrounding tissues.
Joint Test Report For Validation of Alternatives to Aliphatic Isocyanate Polyurethanes
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2007-01-01
National Aeronautics and Space Administration (NASA) and Air Force Space Command (AFSPC) have similar missions and therefore similar facilities and structures in similar environments. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. The most common topcoats used in coating systems are polyurethanes that contain isocyanates. Isocyanates are classified as potential human carcinogens and are known to cause cancer in animals. The primary objective of this effort was to demonstrate and validate alternatives to aliphatic isocyanate polyurethanes resulting in one or more isocyanate-free coatings qualified for use at AFSPC and NASA installations participating in this project. This joint Test Report (JTR) documents the results of the laboratory and field testing as well as any test modifications made during the execution of the testing. The technical stakeholders agreed upon test procedure modifications documented in this document. This JTR is made available as a reference for future pollution prevention endeavors by other NASA centers, the Department of Defense and commercial users to minimize duplication of effort. All coating system candidates were tested using approved NASA and AFSPC standard coating systems as experimental controls. This study looked at eight alternative coating systems and two control coating systems and was divided into Phase I Screening Tests, Phase II Tests, and Field Testing. The Phase I Screening Tests were preliminary tests performed on all the selected candidate coating systems. Candidate coating systems that did not meet the acceptance criteria of the screening tests were eliminated from further testing. Phase I Screening Tests included: Ease of Application, Surface Appearance, Dry-To-Touch (Sanding), Accelerated Storage Stability, Pot Life (Viscosity), Cure Time (Solvent Rubs), Cleanability, Knife Test, Tensile (pull-off) Adhesion, and X-Cut Adhesion by Wet Tape After a review of the Phase I test results, four of the alternative coating systems showed substandard performance in relation to the Control Systems and were eliminated from the Phase II testing. Due to the interest of stakeholders and time constraints, however, all eight alternatives were subjected to the following Phase II tests, along with field testing at Stennis Space Center (SSC), Mississippi: Hypergol Compatibility, Liquid Oxygen Compatibility, 18-Month Marine Exposure (Gloss Retention, Color Retention, Blistering, Visual Corrosion, Creepage from Scribe, Heat Adhesion), and Field Exposure (6- and 12-month Evaluation for Coating Condition, Color Retention, Gloss Retention). The remaining four alternative coating systems determined to be the best viable alternatives were carried on to Phase II testing that included: Removability, Repairability, Abrasion Resistance, Gravelometer, Fungus Resistance, Accelerated Weathering, Mandrel Bend Flexibility, and Cyclic Corrosion Resistance. Of the systems that continued to Phase II, three (3) alternative coating systems meet the performance requirements as identified by stakeholders. Two (2) other systems, that were not included in Phase II testing, performed well enough on the 18-Month Marine Exposure, the primary requirement for NASA technical standard NASA-STD-5008, Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment, that they were also considered to be successful candidates. In total, five (5) alternative coating systems were approved for inclusion in the NASA-STD- 5008 Qualified Products List (QPL). The standard is intended to provide a common framework for consistent practices across NASA and is often used by other entities. The standard's QPL does not connote endorsement of the products by NASA, but lists those products that have been tested and meet the requirements as specified.
25 CFR 170.934 - Are alternative dispute resolution procedures available?
Code of Federal Regulations, 2011 CFR
2011-04-01
... alternative dispute resolution (ADR) procedures is to provide an inexpensive and expeditious forum to resolve... techniques prescribed in: (1) The ADR Act, 5 U.S.C. 571-583; (2) The Contract Disputes Act, 41 U.S.C. 601-613...
25 CFR 170.934 - Are alternative dispute resolution procedures available?
Code of Federal Regulations, 2010 CFR
2010-04-01
... alternative dispute resolution (ADR) procedures is to provide an inexpensive and expeditious forum to resolve... techniques prescribed in: (1) The ADR Act, 5 U.S.C. 571-583; (2) The Contract Disputes Act, 41 U.S.C. 601-613...
48 CFR 715.370 - Alternative source selection procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Alternative source selection procedures. 715.370 Section 715.370 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Source Selection 715...
Code of Federal Regulations, 2011 CFR
2011-10-01
... alternative procedures in conducting a State criminal registry check? (a) FBI fingerprint-based check. If you or your designee conduct and document a fingerprint-based criminal history check through the Federal...
Code of Federal Regulations, 2010 CFR
2010-10-01
... alternative procedures in conducting a State criminal registry check? (a) FBI fingerprint-based check. If you or your designee conduct and document a fingerprint-based criminal history check through the Federal...
Code of Federal Regulations, 2010 CFR
2010-10-01
... alternative procedures in conducting a State criminal registry check? (a) FBI fingerprint-based check. If you or your designee conduct and document a fingerprint-based criminal history check through the Federal...
Code of Federal Regulations, 2012 CFR
2012-10-01
... alternative procedures in conducting a State criminal registry check? (a) FBI fingerprint-based check. If you or your designee conduct and document a fingerprint-based criminal history check through the Federal...
Code of Federal Regulations, 2011 CFR
2011-10-01
... alternative procedures in conducting a State criminal registry check? (a) FBI fingerprint-based check. If you or your designee conduct and document a fingerprint-based criminal history check through the Federal...
Code of Federal Regulations, 2012 CFR
2012-10-01
... alternative procedures in conducting a State criminal registry check? (a) FBI fingerprint-based check. If you or your designee conduct and document a fingerprint-based criminal history check through the Federal...
44 CFR 78.14 - Alternative procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 44 Emergency Management and Assistance 1 2011-10-01 2011-10-01 false Alternative procedures. 78.14 Section 78.14 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION...
44 CFR 78.14 - Alternative procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 44 Emergency Management and Assistance 1 2014-10-01 2014-10-01 false Alternative procedures. 78.14 Section 78.14 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION...
44 CFR 78.14 - Alternative procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 44 Emergency Management and Assistance 1 2012-10-01 2011-10-01 true Alternative procedures. 78.14 Section 78.14 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION...
44 CFR 78.14 - Alternative procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Alternative procedures. 78.14 Section 78.14 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION...
44 CFR 78.14 - Alternative procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 44 Emergency Management and Assistance 1 2013-10-01 2013-10-01 false Alternative procedures. 78.14 Section 78.14 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program FLOOD MITIGATION...
40 CFR 85.2208 - Alternative standards and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 85.2208 Section 85.2208 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Emission Control System Performance... Administrator determines that the alternative standards or procedures satisfy the provisions of the Clean Air...
Asikanius, Elina; Rufibach, Kaspar; Bahlo, Jasmin; Bieska, Gabriele; Burger, Hans Ulrich
2016-11-01
To optimize resources, randomized clinical trials with multiple arms can be an attractive option to simultaneously test various treatment regimens in pharmaceutical drug development. The motivation for this work was the successful conduct and positive final outcome of a three-arm randomized clinical trial primarily assessing whether obinutuzumab plus chlorambucil in patients with chronic lympocytic lymphoma and coexisting conditions is superior to chlorambucil alone based on a time-to-event endpoint. The inference strategy of this trial was based on a closed testing procedure. We compare this strategy to three potential alternatives to run a three-arm clinical trial with a time-to-event endpoint. The primary goal is to quantify the differences between these strategies in terms of the time it takes until the first analysis and thus potential approval of a new drug, number of required events, and power. Operational aspects of implementing the various strategies are discussed. In conclusion, using a closed testing procedure results in the shortest time to the first analysis with a minimal loss in power. Therefore, closed testing procedures should be part of the statistician's standard clinical trials toolbox when planning multiarm clinical trials. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Alternative Approach to Vehicle Element Processing
NASA Technical Reports Server (NTRS)
Huether, Jacob E.; Otto, Albert E.
1995-01-01
The National Space Transportation Policy (NSTP), describes the challenge facing today's aerospace industry. 'Assuring reliable and affordable access to space through U.S. space transportation capabilities is a fundamental goal of the U.S. space program'. Experience from the Space Shuttle Program (SSP) tells us that launch and mission operations are responsible for approximately 45 % of the cost of each shuttle mission. Reducing these costs is critical to NSTP goals in the next generation launch vehicle. Based on this, an innovative alternative approach to vehicle element processing was developed with an emphasis on reduced launch costs. State-of-the-art upgrades to the launch processing system (LPS) will enhance vehicle ground operations. To carry this one step further, these upgrade could be implemented at various vehicle element manufacturing sites to ensure system compatibility between the manufacturing facility and the launch site. Design center vehicle stand alone testing will ensure system integrity resulting in minimized checkout and testing at the launch site. This paper will addresses vehicle test requirements, timelines and ground checkout procedures which enable concept implementation.
Recall and recognition hypermnesia for Socratic stimuli.
Kazén, Miguel; Solís-Macías, Víctor M
2016-01-01
In two experiments, we investigate hypermnesia, net memory improvements with repeated testing of the same material after a single study trial. In the first experiment, we found hypermnesia across three trials for the recall of word solutions to Socratic stimuli (dictionary-like definitions of concepts) replicating Erdelyi, Buschke, and Finkelstein and, for the first time using these materials, for their recognition. In the second experiment, we had two "yes/no" recognition groups, a Socratic stimuli group presented with concrete and abstract verbal materials and a word-only control group. Using signal detection measures, we found hypermnesia for concrete Socratic stimuli-and stable performance for abstract stimuli across three recognition tests. The control group showed memory decrements across tests. We interpret these findings with the alternative retrieval pathways (ARP) hypothesis, contrasting it with alternative theories of hypermnesia, such as depth of processing, generation and retrieve-recognise. We conclude that recognition hypermnesia for concrete Socratic stimuli is a reliable phenomenon, which we found in two experiments involving both forced-choice and yes/no recognition procedures.
Usta, Murat; Aral, Hale; Mete Çilingirtürk, Ahmet; Kural, Alev; Topaç, Ibrahim; Semerci, Tuna; Hicri Köseoğlu, Mehmet
2016-11-01
Average of normals (AON) is a quality control procedure that is sensitive only to systematic errors that can occur in an analytical process in which patient test results are used. The aim of this study was to develop an alternative model in order to apply the AON quality control procedure to datasets that include qualitative values below limit of detection (LoD). The reported patient test results for tumor markers, such as CA 15-3, CA 125, and CA 19-9, analyzed by two instruments, were retrieved from the information system over a period of 5 months, using the calibrator and control materials with the same lot numbers. The median as a measure of central tendency and the median absolute deviation (MAD) as a measure of dispersion were used for the complementary model of AON quality control procedure. The u bias values, which were determined for the bias component of the measurement uncertainty, were partially linked to the percentages of the daily median values of the test results that fall within the control limits. The results for these tumor markers, in which lower limits of reference intervals are not medically important for clinical diagnosis and management, showed that the AON quality control procedure, using the MAD around the median, can be applied for datasets including qualitative values below LoD.
Fractography used with lifetime prediction tests on commercial grades of alumina and silicon carbide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuebler, J.; Woodtli, J.; Berroth, K.
1996-12-31
Fractographic investigations were conducted on alumina and {alpha}-SSiC bend bars from a round robin test comparing a static and a dynamic lifetime test method. The investigations revealed that not all fracture origins found on {alpha}-SSiC specimens had contact with the ambient medium and therefore the dynamic lifetime tests did not measure the materials` behaviour under stress in water. In addition to the conventional SEM fractography an alternate technique, using an auto focus scanning laser profilometer was applied for characterizing the fractures. This tool is very promising for fractography because of the ability to handle topographic data by imaging procedures andmore » fractal analysis.« less
Blood tests for allergy in children. Allergy Section, Canadian Paediatric Society.
1990-01-01
Skin tests and RASTs are important tools but do not by themselves make or exclude the diagnosis of allergy. Positive results require a confirmatory medical history, whereas negative results exclude IgE-mediated allergy with a high degree of reliability. Skins tests are preferred for routine use, because with appropriate procedural controls they are simpler, give rapid results and are cost-effective. RASTs are an excellent alternative when skin tests are precluded. Disorders such as asthma and allergic rhinitis may be provoked by irritants (e.g., cigarette smoke), physical factors (e.g., cold, dry air) and chemical substances (e.g., acetylsalicylic acid) and metabisulfite), none of which involve an IgE-antibody-mediated mechanism. PMID:2344576
Zhang, Niu; Chawla, Sudeep
2012-01-01
This study examined the effect of implementing instructional video in ophthalmic physical examination teaching on chiropractic students' laboratory physical examination skills and written test results. Instructional video clips of ophthalmic physical examination, consisting of both standard procedures and common mistakes, were created and used for laboratory teaching. The video clips were also available for student review after class. Students' laboratory skills and written test results were analyzed and compared using one-way analysis of variance (ANOVA) and post hoc multiple comparison tests among three study cohorts: the comparison cohort who did not utilize the instructional videos as a tool, the standard video cohort who viewed only the standard procedure of video clips, and the mistake-referenced video cohort who viewed video clips containing both standard procedure and common mistakes. One-way ANOVA suggested a significant difference of lab results among the three cohorts. Post hoc multiple comparisons further revealed that the mean scores of both video cohorts were significantly higher than that of the comparison cohort (p < .001). There was, however, no significant difference of the mean scores between the two video cohorts (p > .05). However, the percentage of students having a perfect score was the highest in the mistake-referenced video cohort. There was no significant difference of written test scores among all three cohorts (p > .05). The instructional video of the standard procedure improves chiropractic students' ophthalmic physical examination skills, which may be further enhanced by implementing a mistake-referenced instructional video.
Hydrogen recombiner catalyst test supporting data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, M.D.
1995-01-19
This is a data package supporting the Hydrogen Recombiner Catalyst Performance and Carbon Monoxide Sorption Capacity Test Report, WHC-SD-WM-TRP-211, Rev 0. This report contains 10 appendices which consist of the following: Mass spectrometer analysis reports: HRC samples 93-001 through 93-157; Gas spectrometry analysis reports: HRC samples 93-141 through 93-658; Mass spectrometer procedure PNL-MA-299 ALO-284; Alternate analytical method for ammonia and water vapor; Sample log sheets; Job Safety analysis; Certificate of mixture analysis for feed gases; Flow controller calibration check; Westinghouse Standards Laboratory report on Bois flow calibrator; and Sorption capacity test data, tables, and graphs.
Spring, Michelle A
2018-04-07
Fluid accumulation is a common complication after abdominoplasty procedures, and is typically managed by the placement of post-surgical drains. Progressive tension sutures (PTS) have been shown to be an effective approach to reduce the dead space by point-wise mechanical fixation, allowing for drain-free procedures. Lysine-derived urethane surgical adhesive provides an alternative approach for mechanical fixation and reduction of dead space, and may reduce surgery time compared to PTS. This prospective, controlled, single center clinical study compared progressive tension suture wound closure technique without drains (control) to tissue adhesive wound closure technique without drains (test) during abdominoplasty surgery. The objective was to determine if lysine-derived urethane surgical adhesive is an effective alternative to PTS for drain-free abdominoplasty procedures. Patients undergoing abdominoplasty who met the established inclusion/exclusion criteria were consented and enrolled in the study. Ten PTS (control) cases were performed, followed immediately by ten tissue adhesive (test) cases. Drains were not used in any procedures. Key outcome measures included all major and minor post-surgical complications requiring any intervention, the time to place progressive tension sutures versus time for tissue adhesive application, and number of PTS attachments versus number of adhesive drops applied. Surgeries were completed over an 8-month period. No statistical differences were identified between the two groups with regard to age, BMI, dissection surface area or flap weight. No clinical seroma formation was observed in either group. In the control (PTS) group, two patients developed small areas of dermal closure suture abscess requiring removal of suture material. One control patient developed drainage and fat necrosis thought to be related to PTS above the incision and later required a scar revision. One tissue adhesive patient developed hypertrophic scars of both her breast reduction and abdominoplasty scars requiring additional treatment. The average time to place PTS in the control group was 10.7 minutes (range, 7-18 minutes) and the average number of sutures placed was 16.6 (range, 12-22 sutures). In the test group, the average time to place the tissue adhesive and hold pressure was 5.9 minutes (range 5.5-8.0 minutes). The average number of tissue adhesive drops applied was 69.6 (range: 63-78 drops). In the tissue adhesive group, both the reduction in time for flap adhesion and the increased number of adhesive points were statistically significant when compared to PTS. Lysine-derived urethane surgical adhesive was applied in less time than progressive tension sutures, even after accounting for holding pressure for 5 minutes. The tissue adhesive provided four times the number of attachment points compared to PTS, although the significance of this is not clear. There were no postoperative clinical seromas detected in either group and there were no major complications in either group. Based on these results, the use of lysine-derived urethane surgical adhesive was found to be a safe and effective alternative to progressive tension sutures to reduce seroma formation in drain-free abdominoplasty procedures.
Costa, Alberto; Peppe, Antonella; Serafini, Francesca; Zabberoni, Silvia; Barban, Francesco; Caltagirone, Carlo; Carlesimo, Giovanni Augusto
2014-08-01
This study investigated the effect of cognitive training aimed at improving shifting ability on Parkinson's disease (PD) patients' performance of prospective memory (PM) tasks. Using a double-blind protocol, 17 PD patients were randomly assigned to two experimental arms. In the first arm (n=9) shifting training was administered, and in the second (placebo) arm (n=8), language and respiratory exercises. Both treatments consisted of 12 sessions executed over 4 weeks. PM and shifting measures (i.e., Trail Making Test and Alternate Fluency Test) were administered at T0 (before treatment) and T1 (immediately after treatment). A mixed analysis of variance was applied to the data. To evaluate the effects of treatment, the key effect was the interaction between Group (experimental vs. placebo) and Time of Assessment (T0 vs. T1). This interaction was significant for the accuracy indices of the PM procedure (p<.05) and for the performance parameters of the shifting tasks (p ≤.05). Tukey's HSD tests showed that in all cases passing from T0 to T1 performance significantly improved in the experimental group (in all cases p ≤.02) but remained unchanged in the placebo group (all p consistently>.10). The performance change passing from T0 to T1 on the Alternate Fluency test and the PM procedure was significantly correlated (p<.05). Results show that the cognitive training significantly improved PD patients' event-based PM performance and suggest that their poor PM functioning might be related to reduced shifting abilities.
Impact Testing of a Stirling Converter's Linear Alternator
NASA Technical Reports Server (NTRS)
Suarez, Vicente J.; Goodnight, Thomas W.; Hughes, William O.; Samorezov, Sergey
2002-01-01
The U.S. Department of Energy (DOE), in conjunction with the NASA John H. Glenn Research Center and Stirling Technology Company, are currently developing a Stirling convertor for a Stirling Radioisotope Generator (SRG). NASA Headquarters and DOE have identified the SRG for potential use as an advanced spacecraft power system for future NASA deep-space and Mars surface missions. Low-level dynamic impact tests were conducted at NASA Glenn Research Center's Structural Dynamics Laboratory as part of the development of this technology. The purpose of this test was to identify dynamic structural characteristics of the Stirling Technology Demonstration Convertor (TDC). This paper addresses the test setup, procedure, and results of the impact testing conducted on the Stirling TDC in May 2001.
Impact testing of a Stirling convertor's linear alternator
NASA Astrophysics Data System (ADS)
Suárez, Vicente J.; Goodnight, Thomas W.; Hughes, William O.; Samorezov, Sergey
2002-01-01
The U.S. Department of Energy (DOE), in conjunction with NASA John H. Glenn Research Center and Stirling Technology Company, are currently developing a Stirling convertor for a Stirling Radioisotope Generator (SRG). NASA Headquarters and DOE have identified the SRG for potential use as an advanced spacecraft power system for future NASA deep-space and Mars surface missions. Low-level dynamic impact tests were conducted at NASA Glenn Research Center's Structural Dynamics Laboratory as part of the development of this technology. The purpose of this test was to identify dynamic structural characteristics of the Stirling Technology Demonstration Convertor (TDC). This paper addresses the test setup, procedure and results of the impact testing conducted on the Stirling TDC in May 2001. .
Alternatives to In-Court Testimony in Child Abuse Cases
1992-04-01
federal prosecutions for child abuse . Contrary to the trend in both federal and state courts, the military provides no procedural or judicial...adoption of a rule for courts-martial that would provide uniform procedural alternatives to in-court testimony in child abuse cases.
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Alternative compliance procedure. 435.305 Section 435.305 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.305...
27 CFR 24.136 - Procedure for alternating proprietors.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Procedure for alternating proprietors. (a) General. Wine premises, or parts thereof, may be operated... limited to parts of the wine premises, the application will describe areas, buildings, floors, or rooms... wine premises will be operated. Once the qualifying documents have been approved, and operations...
Motor Development: Manual of Alternative Procedures.
ERIC Educational Resources Information Center
McCormack, James E.
The manual of alternative procedures for teaching handicapped children focuses on programming, planning, and implementing training in the gross motor (posture, limb control, locomotion) and fine motor (facial, digital) skills. The manual consists of the following sections: specific teaching tactics commonly used in motor training stiuations…
33 CFR 127.017 - Alternatives.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Alternatives. 127.017 Section 127... General § 127.017 Alternatives. (a) The COTP may allow alternative procedures, methods, or equipment... written request for the alternative at least 30 days before facility operations under the alternative...
Code of Federal Regulations, 2010 CFR
2010-04-01
... comment period if the State offers an alternative proposal for Class III gaming procedures? 291.9 Section... GAMING PROCEDURES § 291.9 What must the Secretary do at the end of the 60-day comment period if the State offers an alternative proposal for Class III gaming procedures? Within 30 days of receiving the State's...
Engineering analysis of shortfall for new technologies. Analysis memorandum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-03-11
The engineering principles that govern the mpg performance of alternative technologies on the EPA test procedure and under in-use conditions are examined. The results can be used to interpret the shortfall of alternative technologies derived from statistical analyses. The analysis examines each of the four technologies in comparison to the conventional technology counterpart. Manual transmissions are compared to automatics, fuel injected S.I. engines to carburetted S.I. engines, front-wheel drive vehicles to rear-wheel drive vehicles and diesel engines to carburetted S.I. engines. The changes in shortfall of the four technologies in comparison to conventional technologies are explained through differences in responsesmore » to the factors.« less
Preliminary Solar Sail Design and Fabrication Assessment: Spinning Sail Blade, Square Sail Sheet
NASA Technical Reports Server (NTRS)
Daniels, J. B.; Dowdle, D. M.; Hahn, D. W.; Hildreth, E. N.; Lagerquist, D. R.; Mahaonoul, E. J.; Munson, J. B.; Origer, T. F.
1977-01-01
Blade design aspects most affecting producibility and means of measurement and control of length, scallop, fullness and straightness requirements and tolerances were extensively considered. Alternate designs of the panel seams and edge reinforcing members are believed to offer advantages of seam integrity, producibility, reliability, cost and weight. Approaches to and requirements for highly specialized metalizing methods, processes and equipment were studied and identified. Alternate methods of sail blade fabrication and related special machinery, tooling, fixtures and trade offs were examined. A preferred and recommended approach is also described. Quality control plans, inspection procedures, flow charts and special test equipment associated with the preferred manufacturing method were analyzed and are discussed.
Sports drug testing using complementary matrices: Advantages and limitations.
Thevis, Mario; Geyer, Hans; Tretzel, Laura; Schänzer, Wilhelm
2016-10-25
Today, routine doping controls largely rely on testing whole blood, serum, and urine samples. These matrices allow comprehensively covering inorganic as well as low and high molecular mass organic analytes relevant to doping controls and are collecting and transferring from sampling sites to accredited anti-doping laboratories under standardized conditions. Various aspects including time and cost-effectiveness as well as intrusiveness and invasiveness of the sampling procedure but also analyte stability and breadth of the contained information have been motivation to consider and assess values potentially provided and added to modern sports drug testing programs by alternative matrices. Such alternatives could be dried blood spots (DBS), dried plasma spots (DPS), oral fluid (OF), exhaled breath (EB), and hair. In this review, recent developments and test methods concerning these alternative matrices and expected or proven contributions as well as limitations of these specimens in the context of the international anti-doping fight are presented and discussed, guided by current regulations for prohibited substances and methods of doping as established by the World Anti-Doping Agency (WADA). Focusing on literature published between 2011 and 2015, examples for doping control analytical assays concerning non-approved substances, anabolic agents, peptide hormones/growth factors/related substances and mimetics, β 2 -agonists, hormone and metabolic modulators, diuretics and masking agents, stimulants, narcotics, cannabinoids, glucocorticoids, and beta-blockers were selected to outline the advantages and limitations of the aforementioned alternative matrices as compared to conventional doping control samples (i.e. urine and blood/serum). Copyright © 2016 Elsevier B.V. All rights reserved.
Side Effects in Time Discounting Procedures: Fixed Alternatives Become the Reference Point
2016-01-01
Typical research on intertemporal choice utilizes a two-alternative forced choice (2AFC) paradigm requiring participants to choose between a smaller sooner and larger later payoff. In the adjusting-amount procedure (AAP) one of the alternatives is fixed and the other is adjusted according to particular choices made by the participant. Such a method makes the alternatives unequal in status and is speculated to make the fixed alternative a reference point for choices, thereby affecting the decision made. The current study shows that fixing different alternatives in the AAP influences discount rates in intertemporal choices. Specifically, individuals’ (N = 283) choices were affected to just the same extent by merely fixing an alternative as when choices were preceded by scenarios explicitly imposing reference points. PMID:27768759
Raes, Filip; Hermans, Dirk; Williams, J. Mark G.; Eelen, Paul
2007-01-01
Overgeneral memory (OGM) has been proposed as a vulnerability factor for depression (Williams et al., 2007) or depressive reactivity to stressful life-events (e.g., Gibbs & Rude, 2004). Traditionally, a cue word procedure known as the Autobiographical Memory Test (AMT; Williams & Broadbent, 1986) is used to assess OGM. Although frequently and validly used in clinical populations, there is evidence suggesting that the AMT is insufficiently sensitive to measure OGM in non-clinical groups. Study 1 evaluated the usefulness of a sentence completion method to assess OGM in non-clinical groups, as an alternative to the AMT. Participants were 197 students who completed the AMT, the Sentence Completion for Events from the Past Test (SCEPT), a depression measure, and visual analogue scales assessing ruminative thinking. Results showed that the mean proportion of overgeneral responses was markedly higher for the SCEPT than for the standard AMT. Also, overgeneral responding on the SCEPT was positively associated to depression scores and depressive rumination scores, whereas overgeneral responding on the AMT was not. Results suggest that the SCEPT, relative to the AMT, is a more sensitive instrument to measure OGM, at least in non-clinical populations. Study 2 further showed that this enhanced sensitivity is most likely due to the omission of the instruction to be specific rather than to the SCEPT's sentence completion format (as opposed to free recall to cue words). PMID:17613793
Raes, Filip; Hermans, Dirk; Williams, J Mark G; Eelen, Paul
2007-07-01
Overgeneral memory (OGM) has been proposed as a vulnerability factor for depression (Williams et al., 2007) or depressive reactivity to stressful life-events (e.g., Gibbs & Rude, 2004). Traditionally, a cue word procedure known as the Autobiographical Memory Test (AMT; Williams & Broadbent, 1986) is used to assess OGM. Although frequently and validly used in clinical populations, there is evidence suggesting that the AMT is insufficiently sensitive to measure OGM in non-clinical groups. Study 1 evaluated the usefulness of a sentence completion method to assess OGM in non-clinical groups, as an alternative to the AMT. Participants were 197 students who completed the AMT, the Sentence Completion for Events from the Past Test (SCEPT), a depression measure, and visual analogue scales assessing ruminative thinking. Results showed that the mean proportion of overgeneral responses was markedly higher for the SCEPT than for the standard AMT. Also, overgeneral responding on the SCEPT was positively associated to depression scores and depressive rumination scores, whereas overgeneral responding on the AMT was not. Results suggest that the SCEPT, relative to the AMT, is a more sensitive instrument to measure OGM, at least in non-clinical populations. Study 2 further showed that this enhanced sensitivity is most likely due to the omission of the instruction to be specific rather than to the SCEPT's sentence completion format (as opposed to free recall to cue words).
Holzhütter, H G; Genschow, E; Diener, W; Schlede, E
2003-05-01
The acute toxic class (ATC) methods were developed for determining LD(50)/LC(50) estimates of chemical substances with significantly fewer animals than needed when applying conventional LD(50)/LC(50) tests. The ATC methods are sequential stepwise procedures with fixed starting doses/concentrations and a maximum of six animals used per dose/concentration. The numbers of dead/moribund animals determine whether further testing is necessary or whether the test is terminated. In recent years we have developed classification procedures for the oral, dermal and inhalation routes of administration by using biometric methods. The biometric approach assumes a probit model for the mortality probability of a single animal and assigns the chemical to that toxicity class for which the best concordance is achieved between the statistically expected and the observed numbers of dead/moribund animals at the various steps of the test procedure. In previous publications we have demonstrated the validity of the biometric ATC methods on the basis of data obtained for the oral ATC method in two-animal ring studies with 15 participants from six countries. Although the test procedures and biometric evaluations for the dermal and inhalation ATC methods have already been published, there was a need for an adaptation of the classification schemes to the starting doses/concentrations of the Globally Harmonized Classification System (GHS) recently adopted by the Organization for Economic Co-operation and Development (OECD). Here we present the biometric evaluation of the dermal and inhalation ATC methods for the starting doses/concentrations of the GHS and of some other international classification systems still in use. We have developed new test procedures and decision rules for the dermal and inhalation ATC methods, which require significantly fewer animals to provide predictions of toxicity classes, that are equally good or even better than those achieved by using the conventional LD(50)/LC(50) methods. In order to cope with rather narrow dose/concentration classes of the GHS we have, as in our previous publications, combined the outcome of all results that can be obtained during testing for the allocation to one of the defined toxicity classes of the GHS. Our results strongly recommend the deletion of the dermal LD(50) and the inhalation LC(50) test as regulatory tests and the adoption of the dermal and inhalation ATC methods as internationally accepted alternatives.
27 CFR 18.13 - Alternate methods or procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Alternate methods or procedures. 18.13 Section 18.13 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Administrative...
27 CFR 18.13 - Alternate methods or procedures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Alternate methods or procedures. 18.13 Section 18.13 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Administrative...
27 CFR 18.13 - Alternate methods or procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures. 18.13 Section 18.13 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Administrative...
27 CFR 18.13 - Alternate methods or procedures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Alternate methods or procedures. 18.13 Section 18.13 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Administrative...
Akhoun, Idrick; McKay, Colette; El-Deredy, Wael
2015-01-15
Independent-components-analysis (ICA) successfully separated electrically-evoked compound action potentials (ECAPs) from the stimulation artefact and noise (ECAP-ICA, Akhoun et al., 2013). This paper shows how to automate the ECAP-ICA artefact cancellation process. Raw-ECAPs without artefact rejection were consecutively recorded for each stimulation condition from at least 8 intra-cochlear electrodes. Firstly, amplifier-saturated recordings were discarded, and the data from different stimulus conditions (different current-levels) were concatenated temporally. The key aspect of the automation procedure was the sequential deductive source categorisation after ICA was applied with a restriction to 4 sources. The stereotypical aspect of the 4 sources enables their automatic classification as two artefact components, a noise and the sought ECAP based on theoretical and empirical considerations. The automatic procedure was tested using 8 cochlear implant (CI) users and one to four stimulus electrodes. The artefact and noise sources were successively identified and discarded, leaving the ECAP as the remaining source. The automated ECAP-ICA procedure successfully extracted the correct ECAPs compared to standard clinical forward masking paradigm in 22 out of 26 cases. ECAP-ICA does not require extracting the ECAP from a combination of distinct buffers as it is the case with regular methods. It is an alternative that does not have the possible bias of traditional artefact rejections such as alternate-polarity or forward-masking paradigms. The ECAP-ICA procedure bears clinical relevance, for example as the artefact rejection sub-module of automated ECAP-threshold detection techniques, which are common features of CI clinical fitting software. Copyright © 2014. Published by Elsevier B.V.
A general equation to obtain multiple cut-off scores on a test from multinomial logistic regression.
Bersabé, Rosa; Rivas, Teresa
2010-05-01
The authors derive a general equation to compute multiple cut-offs on a total test score in order to classify individuals into more than two ordinal categories. The equation is derived from the multinomial logistic regression (MLR) model, which is an extension of the binary logistic regression (BLR) model to accommodate polytomous outcome variables. From this analytical procedure, cut-off scores are established at the test score (the predictor variable) at which an individual is as likely to be in category j as in category j+1 of an ordinal outcome variable. The application of the complete procedure is illustrated by an example with data from an actual study on eating disorders. In this example, two cut-off scores on the Eating Attitudes Test (EAT-26) scores are obtained in order to classify individuals into three ordinal categories: asymptomatic, symptomatic and eating disorder. Diagnoses were made from the responses to a self-report (Q-EDD) that operationalises DSM-IV criteria for eating disorders. Alternatives to the MLR model to set multiple cut-off scores are discussed.
Second-Order Analysis of Semiparametric Recurrent Event Processes
Guan, Yongtao
2011-01-01
Summary A typical recurrent event dataset consists of an often large number of recurrent event processes, each of which contains multiple event times observed from an individual during a followup period. Such data have become increasingly available in medical and epidemiological studies. In this paper, we introduce novel procedures to conduct second-order analysis for a flexible class of semiparametric recurrent event processes. Such an analysis can provide useful information regarding the dependence structure within each recurrent event process. Specifically, we will use the proposed procedures to test whether the individual recurrent event processes are all Poisson processes and to suggest sensible alternative models for them if they are not. We apply these procedures to a well-known recurrent event dataset on chronic granulomatous disease and an epidemiological dataset on Meningococcal disease cases in Merseyside, UK to illustrate their practical value. PMID:21361885
[From idea to standard care-a field report].
Herberz, Chantal; Steidl, Ralph; Werner, Pascal; Hagen, Julia
2018-03-01
Digital health products and services have started to fundamentally change healthcare and prevention. Products intended for a medical use require CE-marking and potentially certification (ISO 13485) of the company. Startups play an important role in the development of new digital products and services. Two startups share their experience with these processes. Becoming a part of standard care and hence being reimbursed is a challenge for startups. For this reason, startups pursue alternative sources of income, too. The statutory health insurance's procedures for assessing new products and services are perceived as long. Startups are required to provide evidence of the benefit of their product at an early stage in the procedure. This requires time-consuming and costly studies. Startups would therefore appreciate support in generating this evidence, e. g. through adequate procedures for testing.
A universal procedure for evaluation and application of surge-protective devices
NASA Technical Reports Server (NTRS)
1980-01-01
The source, nature, and frequency of occurrence of transients must be identified and a representative standard test wave chosen for proof testing. The performance of candidate suppressor devices then can be evaluated against the withstand goals set for the equipment. The various suppressors divide into two classes of generic behavior. The key to a universal procedure for evaluating both classes lies in representing transients as quasi-current sources of defined current impulse duration. The available surge current is established by the Thevenin equivalent transient voltage and source impedance. A load line drawn on the V-I characteristic graph of the suppressor quickly determines the clamping voltage and peak current. These values then can be compared to the requirement. The deposited energy and average power dissipation for multiple transients also can be calculated. The method is illustrated with a design example for motor vehicle alternator load dump suppression.
''Football'' test coil: a simulated service test of internally-cooled, cabled superconductor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marston, P.G.; Iwasa, Y.; Thome, R.J.
Internally-cooled, cabled superconductor, (ICCS), appears from small-scale tests to be a viable alternative to pool-boiling cooled superconductors for large superconducting magnets. Potential advantages may include savings in helium inventory, smaller structure and ease of fabrication. Questions remain, however, about the structural performance of these systems. The ''football'' test coil has been designed to simulate the actual ''field-current-stress-thermal'' operating conditions of a 25 ka ICCS in a commercial scale MHD magnet. The test procedure will permit demonstration of the 20 year cyclic life of such a magnet in less than 20 days. This paper describes the design, construction and test ofmore » that coil which is wound of copper-stabilized niobium-titanium cable in steel conduit. 2 refs.« less
A nonparametric smoothing method for assessing GEE models with longitudinal binary data.
Lin, Kuo-Chin; Chen, Yi-Ju; Shyr, Yu
2008-09-30
Studies involving longitudinal binary responses are widely applied in the health and biomedical sciences research and frequently analyzed by generalized estimating equations (GEE) method. This article proposes an alternative goodness-of-fit test based on the nonparametric smoothing approach for assessing the adequacy of GEE fitted models, which can be regarded as an extension of the goodness-of-fit test of le Cessie and van Houwelingen (Biometrics 1991; 47:1267-1282). The expectation and approximate variance of the proposed test statistic are derived. The asymptotic distribution of the proposed test statistic in terms of a scaled chi-squared distribution and the power performance of the proposed test are discussed by simulation studies. The testing procedure is demonstrated by two real data. Copyright (c) 2008 John Wiley & Sons, Ltd.
Fuel Economy and Emissions of a Vehicle Equipped with an Aftermarket Flexible-Fuel Conversion Kit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, John F; Huff, Shean P; West, Brian H
2012-04-01
The U.S. Environmental Protection Agency (EPA) grants Certificates of Conformity for alternative fuel conversion systems and also offers other forms of premarket registration of conversion kits for use in vehicles more than two model years old. Use of alternative fuels such as ethanol, natural gas, and propane are encouraged by the Energy Policy Act of 1992. Several original equipment manufacturers (OEMs) produce emissions-certified vehicles capable of using alternative fuels, and several alternative fuel conversion system manufacturers produce EPA-approved conversion systems for a variety of alternative fuels and vehicle types. To date, only one manufacturer (Flex Fuel U.S.) has received EPAmore » certifications for ethanol fuel (E85) conversion kits. This report details an independent evaluation of a vehicle with a legal installation of a Flex Fuel U.S. conversion kit. A 2006 Dodge Charger was baseline tested with ethanol-free certification gasoline (E0) and E20 (gasoline with 20 vol % ethanol), converted to flex-fuel operation via installation of a Flex Box Smart Kit from Flex Fuel U.S., and retested with E0, E20, E50, and E81. Test cycles included the Federal Test Procedure (FTP or city cycle), the highway fuel economy test (HFET), and the US06 test (aggressive driving test). Averaged test results show that the vehicle was emissions compliant on E0 in the OEM condition (before conversion) and compliant on all test fuels after conversion. Average nitrogen oxide (NOx) emissions exceeded the Tier 2/Bin 5 intermediate life NO{sub X} standard with E20 fuel in the OEM condition due to two of three test results exceeding this standard [note that E20 is not a legal fuel for non-flexible-fuel vehicles (non-FFVs)]. In addition, one E0 test result before conversion and one E20 test result after conversion exceeded the NOX standard, although the average result in these two cases was below the standard. Emissions of ethanol and acetaldehyde increased with increasing ethanol, while nonmethane organic gas and CO emissions remained relatively unchanged for all fuels and cycles. Higher fraction ethanol blends appeared to decrease NO{sub X} emissions on the FTP and HFET (after conversion). As expected, fuel economy (miles per gallon) decreased with increasing ethanol content in all cases.« less
23 CFR 645.119 - Alternate procedure.
Code of Federal Regulations, 2011 CFR
2011-04-01
... section, the STD is to act in the relative position of the FHWA for reviewing and approving the... prerequisites for authorizing the utility to proceed with and complete the work. (b) The scope of the STD's... alternate procedure, the STD must file a formal application for approval by the FHWA. The application must...
23 CFR 645.119 - Alternate procedure.
Code of Federal Regulations, 2014 CFR
2014-04-01
... section, the STD is to act in the relative position of the FHWA for reviewing and approving the... prerequisites for authorizing the utility to proceed with and complete the work. (b) The scope of the STD's... alternate procedure, the STD must file a formal application for approval by the FHWA. The application must...
23 CFR 645.119 - Alternate procedure.
Code of Federal Regulations, 2010 CFR
2010-04-01
... section, the STD is to act in the relative position of the FHWA for reviewing and approving the... prerequisites for authorizing the utility to proceed with and complete the work. (b) The scope of the STD's... alternate procedure, the STD must file a formal application for approval by the FHWA. The application must...
23 CFR 645.119 - Alternate procedure.
Code of Federal Regulations, 2013 CFR
2013-04-01
... section, the STD is to act in the relative position of the FHWA for reviewing and approving the... prerequisites for authorizing the utility to proceed with and complete the work. (b) The scope of the STD's... alternate procedure, the STD must file a formal application for approval by the FHWA. The application must...
23 CFR 645.119 - Alternate procedure.
Code of Federal Regulations, 2012 CFR
2012-04-01
... section, the STD is to act in the relative position of the FHWA for reviewing and approving the... prerequisites for authorizing the utility to proceed with and complete the work. (b) The scope of the STD's... alternate procedure, the STD must file a formal application for approval by the FHWA. The application must...
ERIC Educational Resources Information Center
Pustejovsky, James E.; Runyon, Christopher
2014-01-01
Direct observation recording procedures produce reductive summary measurements of an underlying stream of behavior. Previous methodological studies of these recording procedures have employed simulation methods for generating random behavior streams, many of which amount to special cases of a statistical model known as the alternating renewal…
27 CFR 19.665 - Alternate methods or procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Alternate methods or procedures. 19.665 Section 19.665 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Distilled Spirits for Fuel Use...
27 CFR 19.903 - Alternate methods or procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures. 19.903 Section 19.903 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Distilled Spirits For Fuel Use § 19...
22 CFR 143.39 - Alternate funds disbursal procedure.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Alternate funds disbursal procedure. 143.39 Section 143.39 Foreign Relations DEPARTMENT OF STATE CIVIL RIGHTS NONDISCRIMINATION ON THE BASIS OF AGE IN... recipient, any public or non-profit private organization or agency, or State or political subdivision of the...
46 CFR 153.10 - Procedures for requesting alternatives and waivers; termination of waivers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Procedures for requesting alternatives and waivers; termination of waivers. 153.10 Section 153.10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS...
46 CFR 153.10 - Procedures for requesting alternatives and waivers; termination of waivers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Procedures for requesting alternatives and waivers; termination of waivers. 153.10 Section 153.10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS...
46 CFR 153.10 - Procedures for requesting alternatives and waivers; termination of waivers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Procedures for requesting alternatives and waivers; termination of waivers. 153.10 Section 153.10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS...
46 CFR 153.10 - Procedures for requesting alternatives and waivers; termination of waivers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Procedures for requesting alternatives and waivers; termination of waivers. 153.10 Section 153.10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS...
46 CFR 153.10 - Procedures for requesting alternatives and waivers; termination of waivers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Procedures for requesting alternatives and waivers; termination of waivers. 153.10 Section 153.10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS...
Development of a novel micro pattern gaseous detector for cosmic ray muon tomography
NASA Astrophysics Data System (ADS)
Biglietti, M.; Canale, V.; Franchino, S.; Iengo, P.; Iodice, M.; Petrucci, F.
2016-07-01
We propose a novel detector (Thick Groove Detector, TGD) designed for cosmic ray tomography with a spatial resolution of 500 μm, trying to keep the construction procedure as simple as possible and to reduce the operating costs. The TGD belongs to the category of MPGDs with an amplification region less than 1 mm wide formed by alternate anode/cathode microstrips layers at different heights. A first 10×10 cm2 prototype has been built, divided in four sections with different test geometries. We present the construction procedure and the first results in terms of gain and stability. Preliminary studies with cosmic rays are also reported.
Debert, Paula; Huziwara, Edson M; Faggiani, Robson Brino; De Mathis, Maria Eugênia Simões; McIlvane, William J
2009-09-01
Past research has demonstrated emergent conditional relations using a go/no-go procedure with pairs of figures displayed side-by-side on a computer screen. The present study sought to extend applications of this procedure. In Experiment 1, we evaluated whether emergent conditional relations could be demonstrated when two-component stimuli were displayed in figure-ground relationships-abstract figures displayed on backgrounds of different colors. Five normally capable adults participated. During training, each two-component stimulus was presented successively. Responses emitted in the presence of some stimulus pairs (A1B1, A2B2, A3B3, B1C1, B2C2 and B3C3) were reinforced, whereas responses emitted in the presence of other pairs (A1B2, A1B3, A2B1, A2B3, A3B1, A3B2, B1C2, B1C3, B2C1, B2C3, B3C1 and B3C2) were not. During tests, new configurations (AC and CA) were presented, thus emulating structurally the matching-to-sample tests employed in typical equivalence studies. All participants showed emergent relations consistent with stimulus equivalence during testing. In Experiment 2, we systematically replicated the procedures with stimulus compounds consisting of four figures (A1, A2, C1 and C2) and two locations (left - B1 and right - B2). All 6 normally capable adults exhibited emergent stimulus-stimulus relations. Together, these experiments show that the go/no-go procedure is a potentially useful alternative for studying emergent conditional relations when matching-to-sample is procedurally cumbersome or impossible to use.
33 CFR 156.107 - Alternatives.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Alternatives. 156.107 Section 156....107 Alternatives. (a) The COTP may consider and approve alternative procedures, methods, or equipment... operator submits a written request for the alternative at least 30 days before operations under the...
Analysis of Alternative Pre-RNA Splicing in the Mouse Retina Using a Fluorescent Reporter.
Murphy, Daniel; Kolandaivelu, Saravanan; Ramamurthy, Visvanathan; Stoilov, Peter
2016-01-01
In vivo alternative splicing is controlled in a tissue and cell type specific manner. Often individual cellular components of complex tissues will express different splicing programs. Thus, when studying splicing in multicellular organisms it is critical to determine the exon inclusion levels in individual cells positioned in the context of their native tissue or organ. Here we describe how a fluorescent splicing reporter in combination with in vivo electroporation can be used to visualize alternative splicing in individual cells within mature tissues. In a test case we show how the splicing of a photoreceptor specific exon can be visualized within the mouse retina. The retina was chosen as an example of a complex tissue that is fragile and whose cells cannot be studied in culture. With minor modifications to the injection and electroporation procedure, the protocol we outline can be applied to other tissues and organs.
Do gender and directness of trauma exposure moderate PTSD's latent structure?
Frankfurt, Sheila B; Armour, Cherie; Contractor, Ateka A; Elhai, Jon D
2016-11-30
The PTSD diagnosis and latent structure were substantially revised in the transition from DSM-IV to DSM-5. However, three alternative models (i.e., anhedonia model, externalizing behavior model, and hybrid model) of PTSD fit the DSM-5 symptom criteria better than the DSM-5 factor model. Thus, the psychometric performance of the DSM-5 and alternative models' PTSD factor structure needs to be critically evaluated. The current study examined whether gender or trauma directness (i.e., direct or indirect trauma exposure) moderates the PTSD latent structure when using the DSM-5 or alternative models. Model performance was evaluated with measurement invariance testing procedures on a large undergraduate sample (n=455). Gender and trauma directness moderated the DSM-5 PTSD and externalizing behavior model and did not moderate the anhedonia and hybrid models' latent structure. Clinical implications and directions for future research are discussed. Published by Elsevier Ireland Ltd.
Statistical inference methods for two crossing survival curves: a comparison of methods.
Li, Huimin; Han, Dong; Hou, Yawen; Chen, Huilin; Chen, Zheng
2015-01-01
A common problem that is encountered in medical applications is the overall homogeneity of survival distributions when two survival curves cross each other. A survey demonstrated that under this condition, which was an obvious violation of the assumption of proportional hazard rates, the log-rank test was still used in 70% of studies. Several statistical methods have been proposed to solve this problem. However, in many applications, it is difficult to specify the types of survival differences and choose an appropriate method prior to analysis. Thus, we conducted an extensive series of Monte Carlo simulations to investigate the power and type I error rate of these procedures under various patterns of crossing survival curves with different censoring rates and distribution parameters. Our objective was to evaluate the strengths and weaknesses of tests in different situations and for various censoring rates and to recommend an appropriate test that will not fail for a wide range of applications. Simulation studies demonstrated that adaptive Neyman's smooth tests and the two-stage procedure offer higher power and greater stability than other methods when the survival distributions cross at early, middle or late times. Even for proportional hazards, both methods maintain acceptable power compared with the log-rank test. In terms of the type I error rate, Renyi and Cramér-von Mises tests are relatively conservative, whereas the statistics of the Lin-Xu test exhibit apparent inflation as the censoring rate increases. Other tests produce results close to the nominal 0.05 level. In conclusion, adaptive Neyman's smooth tests and the two-stage procedure are found to be the most stable and feasible approaches for a variety of situations and censoring rates. Therefore, they are applicable to a wider spectrum of alternatives compared with other tests.
Statistical Inference Methods for Two Crossing Survival Curves: A Comparison of Methods
Li, Huimin; Han, Dong; Hou, Yawen; Chen, Huilin; Chen, Zheng
2015-01-01
A common problem that is encountered in medical applications is the overall homogeneity of survival distributions when two survival curves cross each other. A survey demonstrated that under this condition, which was an obvious violation of the assumption of proportional hazard rates, the log-rank test was still used in 70% of studies. Several statistical methods have been proposed to solve this problem. However, in many applications, it is difficult to specify the types of survival differences and choose an appropriate method prior to analysis. Thus, we conducted an extensive series of Monte Carlo simulations to investigate the power and type I error rate of these procedures under various patterns of crossing survival curves with different censoring rates and distribution parameters. Our objective was to evaluate the strengths and weaknesses of tests in different situations and for various censoring rates and to recommend an appropriate test that will not fail for a wide range of applications. Simulation studies demonstrated that adaptive Neyman’s smooth tests and the two-stage procedure offer higher power and greater stability than other methods when the survival distributions cross at early, middle or late times. Even for proportional hazards, both methods maintain acceptable power compared with the log-rank test. In terms of the type I error rate, Renyi and Cramér—von Mises tests are relatively conservative, whereas the statistics of the Lin-Xu test exhibit apparent inflation as the censoring rate increases. Other tests produce results close to the nominal 0.05 level. In conclusion, adaptive Neyman’s smooth tests and the two-stage procedure are found to be the most stable and feasible approaches for a variety of situations and censoring rates. Therefore, they are applicable to a wider spectrum of alternatives compared with other tests. PMID:25615624
Divine, George; Norton, H James; Hunt, Ronald; Dienemann, Jacqueline
2013-09-01
When a study uses an ordinal outcome measure with unknown differences in the anchors and a small range such as 4 or 7, use of the Wilcoxon rank sum test or the Wilcoxon signed rank test may be most appropriate. However, because nonparametric methods are at best indirect functions of standard measures of location such as means or medians, the choice of the most appropriate summary measure can be difficult. The issues underlying use of these tests are discussed. The Wilcoxon-Mann-Whitney odds directly reflects the quantity that the rank sum procedure actually tests, and thus it can be a superior summary measure. Unlike the means and medians, its value will have a one-to-one correspondence with the Wilcoxon rank sum test result. The companion article appearing in this issue of Anesthesia & Analgesia ("Aromatherapy as Treatment for Postoperative Nausea: A Randomized Trial") illustrates these issues and provides an example of a situation for which the medians imply no difference between 2 groups, even though the groups are, in fact, quite different. The trial cited also provides an example of a single sample that has a median of zero, yet there is a substantial shift for much of the nonzero data, and the Wilcoxon signed rank test is quite significant. These examples highlight the potential discordance between medians and Wilcoxon test results. Along with the issues surrounding the choice of a summary measure, there are considerations for the computation of sample size and power, confidence intervals, and multiple comparison adjustment. In addition, despite the increased robustness of the Wilcoxon procedures relative to parametric tests, some circumstances in which the Wilcoxon tests may perform poorly are noted, along with alternative versions of the procedures that correct for such limitations.
Silay, E; Candirli, C; Taskesen, F; Coskuner, I; Ceyhanli, K T; Yildiz, H
2013-01-01
The aim of our study was to evaluate the likelihood that conscious sedation (CS) with intravenous midazolam could become an alternative modality to general anesthesia (GA) for dental procedures. In our study, 58 and 47 American Society of Anesthesiologists (ASA)-1 pediatric patients, aged 2-12 (mean 6) years, underwent dental procedures and minor oral surgical procedures under GA and CS with intravenous midazolam, respectively. The two groups were evaluated in terms of vital signs, duration of the treatment procedure, patient behavior, and the treatment comfort experienced by the physicians. The oxygen saturation level was significantly lower (GA: 99.0 ± 0.30, CS: 98.4 ± 1.02; P < 0.001) and the duration of the treatment procedure was significantly shorter (P < 0.001) in the sedation group compared with the GA group. The physicians encountered various difficulties during implementation of the treatment strategy in cases where they used CS. Minor oral surgical procedures and tooth extraction processes requiring no saline irrigation, however, could be performed successfully under CS. In cases requiring multiple dental management issues, the sedation method was not found to be a useful alternative to GA.