Test/QA Plan (TQAP) for Verification of Semi-Continuous Ambient Air Monitoring Systems
The purpose of the semi-continuous ambient air monitoring technology (or MARGA) test and quality assurance plan is to specify procedures for a verification test applicable to commercial semi-continuous ambient air monitoring technologies. The purpose of the verification test is ...
The verification test was conducted oer a period of 30 days (October 1 to October 31, 2008) and involved the continuous operation of duplicate semi-continuous monitoring technologies at the Burdens Creek Air Monitoring Site, an existing ambient-air monitoring station located near...
Infrared Laser System for Extended Area Monitoring of Air Pollution
NASA Technical Reports Server (NTRS)
Snowman, L. R.; Gillmeister, R. J.
1971-01-01
An atmospheric pollution monitoring system using a spectrally scanning laser has been developed by the General Electric Company. This paper will report on an evaluation of a breadboard model, and will discuss applications of the concept to various ambient air monitoring situations. The system is adaptable to other tunable lasers. Operating in the middle infrared region, the system uses retroreflectors to measure average concentrations over long paths at low, safe power levels. The concept shows promise of meeting operational needs in ambient air monitoring and providing new data for atmospheric research.
Test/QA Plan for Verification of Semi-Continuous Ambient Air Monitoring Systems - Second Round
Test/QA Plan for Verification of Semi-Continuous Ambient Air Monitoring Systems - Second Round. Changes reflect performance of second round of testing at new location and with various changes to personnel. Additional changes reflect general improvements to the Version 1 test/QA...
[The health status of children from industrial towns due ambient air pollution].
Meĭbaliev, M T
2008-01-01
The author's observations suggest that hygienic monitoring in an industrial city should be made in two areas: 1) ambient air quality and 2) human health. Ambient air quality should be monitored in each town in accordance with an individual program, by taking into account the volume and nature of hazardous substances from the stationary stations, as well as weather conditions, the planning system of residential areas, and the layout of an industrial zone. Monitoring of the population's health in the industrial town should be adapted to the forms and conditions of ambient air quality monitoring in order to reveal environmental pollution-induced changes.
Basic Information about Air Emissions Monitoring
This site is about types of air emissions monitoring and the Clean Air Act regulations, including Ambient Air Quality Monitoring, Stationary Source Emissions Monitoring, and Continuous Monitoring Systems.
PE Padgett
2010-01-01
Nylon and Teflon filter media are frequently used for monitoring ambient air pollutants. These media are subject to many environmental factors that may influence adsorption and retention of particulate and gaseous nitrogenous pollutants. This study evaluated the effects of ozone and humidity on the efficacy of nylon and Teflon filters used in the US dry deposition...
NASA Astrophysics Data System (ADS)
Saad, W. H. M.; Khoo, C. W.; Rahman, S. I. Ab; Ibrahim, M. M.; Saad, N. H. M.
2017-06-01
Getting enough sleep at the right times can help in improving quality of life and protect mental and physical health. This study proposes a portable sleep monitoring device to determine the relationship between the room ambient and quality of sleep. Body condition parameter such as heart rate, body temperature and body movement was used to determine quality of sleep and Audio/video-based monitoring system. The functionality test on all sensors is carried out to make sure that all sensors is working properly. The functionality of the overall system is designed for a better experience with a very minimal intervention to the user. The simple test on the body condition (body temperature and heart rate) while asleep with several different ambient parameters (humidity, brightness and temperature) are varied and the result shows that someone has a better sleep in a dark and colder ambient. This can prove by lower body temperature and lower heart rate.
AMBIENT CARBON MONOXIDE MONITOR
A portable instrument has been designed and two units have been built to monitor the concentration of CO in ambient air. The air flows through a sampling section that is approximately 43 cm long with a 28-pass optical system that produces a total path of 12 meters. Gas-filter cor...
Real-Time Remote Monitoring with Data Acquisition System
NASA Astrophysics Data System (ADS)
Faizal Zainal Abidin, Ahmad; Huzaimy Jusoh, Mohammad; James, Elster; Junid, Syed Abdul Mutalib Al; Mohd Yassin, Ahmad Ihsan
2015-11-01
The purpose of this system is to provide monitoring system for an electrical device and enable remote monitoring via web based application. This monitoring system allow the user to monitor the device condition from anywhere as the information will be synchronised to the website. The current and voltage reading of the monitored equipment, ambient temperature and humidity level are monitored and recorded. These parameters will be updated on the web page. All these sensor are connected to the microcontroller and the data will saved in micro secure digital (SD) card and send all the gathered information to a web page using the GPRS service connection synchronously. The collected data will be displayed on the website and the user enable to download the data directly from the website. The system will help user to monitor the devices condition and ambient changes with ease. The system is successfully developed, tested and has been installed at residential area in Taman Cahaya Alam, Section U12, Shah Alam, Selangor, Malaysia.
Practical method for appearance match between soft copy and hard copy
NASA Astrophysics Data System (ADS)
Katoh, Naoya
1994-04-01
CRT monitors are often used as a soft proofing device for the hard copy image output. However, what the user sees on the monitor does not match its output, even if the monitor and the output device are calibrated with CIE/XYZ or CIE/Lab. This is especially obvious when correlated color temperature (CCT) of CRT monitor's white point significantly differs from ambient light. In a typical office environment, one uses a computer graphic monitor having a CCT of 9300K in a room of white fluorescent light of 4150K CCT. In such a case, human visual system is partially adapted to the CRT monitor's white point and partially to the ambient light. The visual experiments were performed on the effect of the ambient lighting. Practical method for soft copy color reproduction that matches the hard copy image in appearance is presented in this paper. This method is fundamentally based on a simple von Kries' adaptation model and takes into account the human visual system's partial adaptation and contrast matching.
A STRATEGY FOR PROTECTING CIRCULATING SEAWATER SYSTEMS FROM OIL SPILLS
A strategy is described for establishing a simple, inexpensive monitoring program for determining approximate levels of petroleum hydrocarbons in ambient water collected near intake structures of circulating seawater systems. The ambient water is obtained from the depth of intake...
The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily base...
A Java Program for the Viewing of Ambient Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, A.
2004-09-03
The BaBar detector system has a large number of sensors and data feeds, called ambient feeds. These feeds are vital to the operation and monitoring of the Pep rings and the BaBar system. In order to more easily monitor these systems a simple web interface to display graphical representations of the data is needed. Towards this end it was decided that using a Java Web Servlet (Sun Microsystems) would be an effective and simple way to achieve this effect. By combining Web Servlets with the Corba Technology (OMG) this provides a way for many people to access data from anywheremore » in the world. Using this type of program in conjunction with the HEP AIDA systems for graphing makes a powerful tool for the monitoring of the BaBar system. An overview of the BaBar system, and how the Ambient data is given. The uses and limitations of this method for viewing the data as well as examples of other ways to access the data and potential other uses for the servlet are also discussed.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
..., tribal entities, environmental groups, academic institutions, industrial groups) use the ambient air... System (AQS) database. Quality assurance/quality control records and monitoring network documentation are...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
Noninvasive health condition monitoring device for workers at high altitudes conditions.
Aqueveque, Pablo; Gutierrez, Cristopher; Saavedra, Francisco; Pino, Esteban J
2016-08-01
This work presents the design and implementation of a continuous monitoring device to control the health state of workers, for instance miners, at high altitudes. The extreme ambient conditions are harmful for peoples' health; therefore a continuous control of the workers' vital signs is necessary. The developed system includes physiological variables: electrocardiogram (ECG), respiratory activity and body temperature (BT), and ambient variables: ambient temperature (AT) and relative humidity (RH). The noninvasive sensors are incorporated in a t-shirt to deliver a functional device, and maximum comfort to the users. The device is able to continuously calculate heart rate (HR) and respiration rate (RR), and establish a wireless data transmission to a central monitoring station.
Sturman, Andrew; Titov, Mikhail; Zawar-Reza, Peyman
2011-01-15
Installation of temporary or long term monitoring sites is expensive, so it is important to rationally identify potential locations that will achieve the requirements of regional air quality management strategies. A simple, but effective, numerical approach to selecting ambient particulate matter (PM) monitoring site locations has therefore been developed using the MM5-CAMx4 air pollution dispersion modelling system. A new method, 'site efficiency,' was developed to assess the ability of any monitoring site to provide peak ambient air pollution concentrations that are representative of the urban area. 'Site efficiency' varies from 0 to 100%, with the latter representing the most representative site location for monitoring peak PM concentrations. Four heavy pollution episodes in Christchurch (New Zealand) during winter 2005, representing 4 different aerosol dispersion patterns, were used to develop and test this site assessment technique. Evaluation of the efficiency of monitoring sites was undertaken for night and morning aerosol peaks for 4 different particulate material (PM) spatial patterns. The results demonstrate that the existing long term monitoring site at Coles Place is quite well located, with a site efficiency value of 57.8%. A temporary ambient PM monitoring site (operating during winter 2006) showed a lower ability to capture night and morning peak aerosol concentrations. Evaluation of multiple site locations used during an extensive field campaign in Christchurch (New Zealand) in 2000 indicated that the maximum efficiency achieved by any site in the city would be 60-65%, while the efficiency of a virtual background site is calculated to be about 7%. This method of assessing the appropriateness of any potential monitoring site can be used to optimize monitoring site locations for any air pollution measurement programme. Copyright © 2010 Elsevier B.V. All rights reserved.
Lupo, Philip J; Symanski, Elaine
2009-11-01
Often, in studies evaluating the health effects of hazardous air pollutants (HAPs), researchers rely on ambient air levels to estimate exposure. Two potential data sources are modeled estimates from the U.S. Environmental Protection Agency (EPA) Assessment System for Population Exposure Nationwide (ASPEN) and ambient air pollutant measurements from monitoring networks. The goal was to conduct comparisons of modeled and monitored estimates of HAP levels in the state of Texas using traditional approaches and a previously unexploited method, concordance correlation analysis, to better inform decisions regarding agreement. Census tract-level ASPEN estimates and monitoring data for all HAPs throughout Texas, available from the EPA Air Quality System, were obtained for 1990, 1996, and 1999. Monitoring sites were mapped to census tracts using U.S. Census data. Exclusions were applied to restrict the monitored data to measurements collected using a common sampling strategy with minimal missing values over time. Comparisons were made for 28 HAPs in 38 census tracts located primarily in urban areas throughout Texas. For each pollutant and by year of assessment, modeled and monitored air pollutant annual levels were compared using standard methods (i.e., ratios of model-to-monitor annual levels). Concordance correlation analysis was also used, which assesses linearity and agreement while providing a formal method of statistical inference. Forty-eight percent of the median model-to-monitor values fell between 0.5 and 2, whereas only 17% of concordance correlation coefficients were significant and greater than 0.5. On the basis of concordance correlation analysis, the findings indicate there is poorer agreement when compared with the previously applied ad hoc methods to assess comparability between modeled and monitored levels of ambient HAPs.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... its Technical System Audit of the CARB PQAO (conducted during Summer 2007), that the combined ambient... findings of EPA's Summer 2007 Technical System Audit of CARB's ambient air monitoring program). \\15\\ See, e... through www.regulations.gov or email. www.regulations.gov is an ``anonymous access'' system, and EPA will...
Method for controlling exhaust gas heat recovery systems in vehicles
Spohn, Brian L.; Claypole, George M.; Starr, Richard D
2013-06-11
A method of operating a vehicle including an engine, a transmission, an exhaust gas heat recovery (EGHR) heat exchanger, and an oil-to-water heat exchanger providing selective heat-exchange communication between the engine and transmission. The method includes controlling a two-way valve, which is configured to be set to one of an engine position and a transmission position. The engine position allows heat-exchange communication between the EGHR heat exchanger and the engine, but does not allow heat-exchange communication between the EGHR heat exchanger and the oil-to-water heat exchanger. The transmission position allows heat-exchange communication between the EGHR heat exchanger, the oil-to-water heat exchanger, and the engine. The method also includes monitoring an ambient air temperature and comparing the monitored ambient air temperature to a predetermined cold ambient temperature. If the monitored ambient air temperature is greater than the predetermined cold ambient temperature, the two-way valve is set to the transmission position.
Detection of nitrogen dioxide by CW cavity-enhanced spectroscopy
NASA Astrophysics Data System (ADS)
Jie, Guo; Han, Ye-Xing; Yu, Zhi-Wei; Tang, Huai-Wu
2016-11-01
In the paper, an accurate and sensitive system was used to monitor the ambient atmospheric NO2 concentrations. This system utilizes cavity attenuated phase shift spectroscopy(CAPS), a technology related to cavity ring down spectroscopy(CRDS). Advantages of the CAPS system include such as: (1) cheap and easy to control the light source, (2) high accuracy, and (3) low detection limit. The performance of the CAPS system was evaluated by measuring of the stability and response of the system. The minima ( 0.08 ppb NO2) in the Allan plots show the optimum average time( 100s) for optimum detection performance of the CAPS system. Over a 20-day-long period of the ambient atmospheric NO2 concentrations monitoring, a comparison of the CAPS system with an extremely accurate and precise chemiluminescence-based NOx analyzer showed that the CAPS system was able to reliably and quantitatively measure both large and small fluctuations in the ambient nitrogen dioxide concentration. The experimental results show that the measuring instrument results correlation is 0.95.
77 FR 43196 - Approval and Promulgation of Implementation Plans; North Carolina; 110(a)(1) and (2...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... quality monitoring/data system: NCAC 2D.0600, Monitoring, and 2D.0806, Ambient Monitoring and Modeling... protected. The www.regulations.gov Web site is an ``anonymous access'' system, which means EPA will not know... requirements, including emissions inventories, monitoring, and modeling to assure attainment and maintenance of...
Air Quality System (AQS) Metadata
The U.S. Environmental Protection Agency compiles air quality monitoring data in the Air Quality System (AQS). Ambient air concentrations are measured at a national network of more than 4,000 monitoring stations and are reported by state, local, and tribal
Ambient Monitoring Technology Information Center (AMTIC)
This site contains information on ambient air quality monitoring programs, monitoring methods, quality assurance and control procedures, and federal regulations related to ambient air quality monitoring.
Applying Formal Verification Techniques to Ambient Assisted Living Systems
NASA Astrophysics Data System (ADS)
Benghazi, Kawtar; Visitación Hurtado, María; Rodríguez, María Luisa; Noguera, Manuel
This paper presents a verification approach based on timed traces semantics and MEDISTAM-RT [1] to check the fulfillment of non-functional requirements, such as timeliness and safety, and assure the correct functioning of the Ambient Assisted Living (AAL) systems. We validate this approach by its application to an Emergency Assistance System for monitoring people suffering from cardiac alteration with syncope.
Crooks, Michael G; den Brinker, Albertus; Hayman, Yvette; Williamson, James D; Innes, Andrew; Wright, Caroline E; Hill, Peter; Morice, Alyn H
2017-06-01
Cough is common in chronic obstructive pulmonary disease (COPD) and is associated with frequent exacerbations and increased mortality. Cough increases during acute exacerbations (AE-COPD), representing a possible metric of clinical deterioration. Conventional cough monitors accurately report cough counts over short time periods. We describe a novel monitoring system which we used to record cough continuously for up to 45 days during AE-COPD convalescence. This is a longitudinal, observational study of cough monitoring in AE-COPD patients discharged from a single teaching hospital. Ambient sound was recorded from two sites in the domestic environment and analysed using novel cough classifier software. For comparison, the validated hybrid HACC/LCM cough monitoring system was used on days 1, 5, 20 and 45. Patients were asked to record symptoms daily using diaries. Cough monitoring data were available for 16 subjects with a total of 568 monitored days. Daily cough count fell significantly from mean ± SEM 272.7 ± 54.5 on day 1 to 110.9 ± 26.3 on day 9 (p < 0.01) before plateauing. The absolute cough count detected by the continuous monitoring system was significantly lower than detected by the hybrid HACC/LCM system but normalised counts strongly correlated (r = 0.88, p < 0.01) demonstrating an ability to detect trends. Objective cough count and subjective cough scores modestly correlated (r = 0.46). Cough frequency declines significantly following AE-COPD and the reducing trend can be detected using continuous ambient sound recording and novel cough classifier software. Objective measurement of cough frequency has the potential to enhance our ability to monitor the clinical state in patients with COPD.
Ambient air monitoring of Beijing MSW logistics facilities in 2006.
Li, Chun-Ping; Li, Guo-Xue; Luo, Yi-Ming; Li, Yan-Fu
2008-11-01
In China, "green" integrated waste management methods are being implemented in response to environmental concerns. We measured the air quality at several municipal solid waste (MSW) sites to provide information for the incorporation of logistics facilities within the current integrated waste management system. We monitored ambient air quality at eight MSW collecting stations, five transfer stations, one composting plant, and five disposal sites in Beijing during April 2006. Composite air samples were collected and analyzed for levels of odor, ammonia (NH3), hydrogen sulfide (H2S), total suspended particles (TSPs), carbon monoxide (CO), sulfur dioxide (SO2), and nitrogen dioxide (NO2). The results of our atmospheric monitoring demonstrated that although CO and SO2 were within acceptable emission levels according to ambient standards, levels of H2S, TSP, and NO2 in the ambient air at most MSW logistics facilities far exceeded ambient limits established for China. The primary pollutants in the ambient air at Beijing MSW logistics facilities were H2S, TSPs, NO2, and odor. To improve current environmental conditions at MSW logistics facilities, the Chinese government encourages the separation of biogenic waste from MSW at the source.
Methods for chemical analysis of water and wastes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-03-01
This manual provides test procedures approved for the monitoring of water supplies, waste discharges, and ambient waters, under the Safe Drinking Water Act, the National Pollutant Discharge Elimination System, and Ambient Monitoring Requirements of Section 106 and 208 of Public Law 92-500. The test methods have been selected to meet the needs of federal legislation and to provide guidance to laboratories engaged in the protection of human health and the aquatic environment.
NASA Astrophysics Data System (ADS)
Kuang, Ye; Zhao, Chun Sheng; Zhao, Gang; Tao, Jiang Chuan; Xu, Wanyun; Ma, Nan; Bian, Yu Xuan
2018-05-01
Water condensed on ambient aerosol particles plays significant roles in atmospheric environment, atmospheric chemistry and climate. Before now, no instruments were available for real-time monitoring of ambient aerosol liquid water contents (ALWCs). In this paper, a novel method is proposed to calculate ambient ALWC based on measurements of a three-wavelength humidified nephelometer system, which measures aerosol light scattering coefficients and backscattering coefficients at three wavelengths under dry state and different relative humidity (RH) conditions, providing measurements of light scattering enhancement factor f(RH). The proposed ALWC calculation method includes two steps: the first step is the estimation of the dry state total volume concentration of ambient aerosol particles, Va(dry), with a machine learning method called random forest model based on measurements of the dry
nephelometer. The estimated Va(dry) agrees well with the measured one. The second step is the estimation of the volume growth factor Vg(RH) of ambient aerosol particles due to water uptake, using f(RH) and the Ångström exponent. The ALWC is calculated from the estimated Va(dry) and Vg(RH). To validate the new method, the ambient ALWC calculated from measurements of the humidified nephelometer system during the Gucheng campaign was compared with ambient ALWC calculated from ISORROPIA thermodynamic model using aerosol chemistry data. A good agreement was achieved, with a slope and intercept of 1.14 and -8.6 µm3 cm-3 (r2 = 0.92), respectively. The advantage of this new method is that the ambient ALWC can be obtained solely based on measurements of a three-wavelength humidified nephelometer system, facilitating the real-time monitoring of the ambient ALWC and promoting the study of aerosol liquid water and its role in atmospheric chemistry, secondary aerosol formation and climate change.
A configurable sensor network applied to ambient assisted living.
Villacorta, Juan J; Jiménez, María I; Del Val, Lara; Izquierdo, Alberto
2011-01-01
The rising older people population has increased the interest in ambient assisted living systems. This article presents a system for monitoring the disabled or older persons developed from an existing surveillance system. The modularity and adaptability characteristics of the system allow an easy adaptation for a different purpose. The proposed system uses a network of sensors capable of motion detection that includes fall warning, identification of persons and a configurable control system which allows its use in different scenarios.
Ambient changes in tracer concentrations from a multilevel monitoring system in Basalt
Bartholomay, Roy C.; Twining, Brian V.; Rose, Peter E.
2014-01-01
Starting in 2008, a 4-year tracer study was conducted to evaluate ambient changes in groundwater concentrations of a 1,3,6-naphthalene trisulfonate tracer that was added to drill water. Samples were collected under open borehole conditions and after installing a multilevel groundwater monitoring system completed with 11 discrete monitoring zones within dense and fractured basalt and sediment layers in the eastern Snake River aquifer. The study was done in cooperation with the U.S. Department of Energy to test whether ambient fracture flow conditions were sufficient to remove the effects of injected drill water prior to sample collection. Results from thief samples indicated that the tracer was present in minor concentrations 28 days after coring, but was not present 6 months after coring or 7 days after reaming the borehole. Results from sampling the multilevel monitoring system indicated that small concentrations of the tracer remained in 5 of 10 zones during some period after installation. All concentrations were several orders of magnitude lower than the initial concentrations in the drill water. The ports that had remnant concentrations of the tracer were either located near sediment layers or were located in dense basalt, which suggests limited groundwater flow near these ports. The ports completed in well-fractured and vesicular basalt had no detectable concentrations.
A field portable mass spectrometer for monitoring organic vapors.
Meier, R W
1978-03-01
A portable mass spectrometer has been designed and built under the sponsorship of the US Army for the purpose of monitoring low concentrations of specified organics in the ambient atmosphere. The goals of the development were discrimination, sensitivity, portability, simplicity of operation, economy and convenience. These objectives were met in a system consisting of a computer operated mass spectrometer with a Llewellyn membrane separator inlet system housed in two 26 x 18 x 9 inch aluminum cases with a total weight less than 150 pounds. This system has shown the capability for field detection of hundreds of specific organic vapors at the parts per billion level in the ambient and workplace environments.
Ning, Zhi; Ye, Sheng; Sun, Li; Yang, Fenhuan; Wong, Ka Chun; Westerdahl, Dane; Louie, Peter K. K.
2018-01-01
The increasing applications of low-cost air sensors promises more convenient and cost-effective systems for air monitoring in many places and under many conditions. However, the data quality from such systems has not been fully characterized and may not meet user expectations in research and regulatory uses, or for use in citizen science. In our study, electrochemical sensors (Alphasense B4 series) for carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO2), and oxidants (Ox) were evaluated under controlled laboratory conditions to identify the influencing factors and quantify their relation with sensor outputs. Based on the laboratory tests, we developed different correction methods to compensate for the impact of ambient conditions. Further, the sensors were assembled into a monitoring system and tested in ambient conditions in Hong Kong side-by-side with regulatory reference monitors, and data from these tests were used to evaluate the performance of the models, to refine them, and validate their applicability in variable ambient conditions in the field. The more comprehensive correction models demonstrated enhanced performance when compared with uncorrected data. One over-arching observation of this study is that the low-cost sensors may promise excellent sensitivity and performance, but it is essential for users to understand and account for several key factors that may strongly affect the nature of sensor data. In this paper, we also evaluated factors of multi-month stability, temperature, and humidity, and considered the interaction of oxidant gases NO2 and ozone on a newly introduced oxidant sensor. PMID:29360749
Wei, Peng; Ning, Zhi; Ye, Sheng; Sun, Li; Yang, Fenhuan; Wong, Ka Chun; Westerdahl, Dane; Louie, Peter K K
2018-01-23
The increasing applications of low-cost air sensors promises more convenient and cost-effective systems for air monitoring in many places and under many conditions. However, the data quality from such systems has not been fully characterized and may not meet user expectations in research and regulatory uses, or for use in citizen science. In our study, electrochemical sensors (Alphasense B4 series) for carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO₂), and oxidants (O x ) were evaluated under controlled laboratory conditions to identify the influencing factors and quantify their relation with sensor outputs. Based on the laboratory tests, we developed different correction methods to compensate for the impact of ambient conditions. Further, the sensors were assembled into a monitoring system and tested in ambient conditions in Hong Kong side-by-side with regulatory reference monitors, and data from these tests were used to evaluate the performance of the models, to refine them, and validate their applicability in variable ambient conditions in the field. The more comprehensive correction models demonstrated enhanced performance when compared with uncorrected data. One over-arching observation of this study is that the low-cost sensors may promise excellent sensitivity and performance, but it is essential for users to understand and account for several key factors that may strongly affect the nature of sensor data. In this paper, we also evaluated factors of multi-month stability, temperature, and humidity, and considered the interaction of oxidant gases NO₂ and ozone on a newly introduced oxidant sensor.
40 CFR 58.14 - System modification.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.14 System modification. (a) The State, or where... monitoring network that complies with the findings of the network assessments required every 5 years by § 58... schedule with respect to the SLAMS network are subject to the approval of the EPA Regional Administrator...
40 CFR 58.14 - System modification.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.14 System modification. (a) The State, or where... monitoring network that complies with the findings of the network assessments required every 5 years by § 58... schedule with respect to the SLAMS network are subject to the approval of the EPA Regional Administrator...
Earth resources data acquisition sensor study
NASA Technical Reports Server (NTRS)
Grohse, E. W.
1975-01-01
The minimum data collection and data processing requirements are investigated for the development of water monitoring systems, which disregard redundant and irrelevant data and process only those data predictive of the onset of significant pollution events. Two approaches are immediately suggested: (1) adaptation of a presently available ambient air monitoring system developed by TVA, and (2) consideration of an air, water, and radiological monitoring system developed by the Georgia Tech Experiment Station. In order to apply monitoring systems, threshold values and maximum allowable rates of change of critical parameters such as dissolved oxygen and temperature are required.
WORKSHOP ON SOURCE EMISSION AND AMBIENT AIR MONITORING OF MERCURY
AN EPA/ORD Workshop on Source Emission and Ambient Air Monitoring of Mercury was held on 9/13-14/99, Bloomington, Minnesota. The purpose of the workshop was to discuss the state-of-the-science in source and ambient air mercury monitoring as well as mercury monitoring research and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-22
... emissions inventories, monitoring, and modeling, to assure attainment and maintenance of the standards... NAAQS required the deployment of a system of new monitors to measure ambient levels of that new... requirements, including emissions inventories, monitoring, and modeling to assure attainment and maintenance of...
Continuous emission monitoring and accounting automated systems at an HPP
NASA Astrophysics Data System (ADS)
Roslyakov, P. V.; Ionkin, I. L.; Kondrateva, O. E.; Borovkova, A. M.; Seregin, V. A.; Morozov, I. V.
2015-03-01
Environmental and industrial emission monitoring at HPP's is a very urgent task today. Industrial monitoring assumes monitoring of emissions of harmful pollutants and optimization of fuel combustion technological processes at HPP's. Environmental monitoring is a system to assess ambient air quality with respect to a number of separate sources of harmful substances in pollution of atmospheric air of the area. Works on creating an industrial monitoring system are carried out at the National Research University Moscow Power Engineering Institute (MPEI) on the basis of the MPEI combined heat and power plant, and environmental monitoring stations are installed in Lefortovo raion, where the CHPP is located.
Ageing-in-place with the use of ambient intelligence technology: perspectives of older users.
van Hoof, J; Kort, H S M; Rutten, P G S; Duijnstee, M S H
2011-05-01
Ambient intelligence technologies are a means to support ageing-in-place by monitoring clients in the home. In this study, monitoring is applied for the purpose of raising an alarm in an emergency situation, and thereby, providing an increased sense of safety and security. Apart from these technological solutions, there are numerous environmental interventions in the home environment that can support people to age-in-place. The aim of this study was to investigate the needs and motives, related to ageing-in-place, of the respondents receiving ambient intelligence technologies, and to investigate whether, and how, these technologies contributed to aspects of ageing-in-place. This paper presents the results of a qualitative study comprised of interviews and observations of technology and environmental interventions in the home environment among 18 community-dwelling older adults with a complex demand for care. These respondents had a prototype of the Unattended Autonomous Surveillance system, an example of ambient intelligence technology, installed in their homes as a means to age-in-place. The UAS-system offers a large range of functionalities, including mobility monitoring, voice response, fire detection, as well as wandering detection and prevention, which can be installed in different configurations. The respondents had various motives to use ambient intelligence technologies to support ageing-in-place. The most prominent reason was to improve the sense of safety and security, in particular, in case of fall incidents, when people were afraid not to be able to use their existing emergency response systems. The ambient intelligence technologies were initially seen as a welcome addition to strategies already adopted by the respondents, including a variety of home modifications and assistive devices. The systems tested increased the sense of safety and security and helped to postpone institutionalisation. Respondents came up with a set of specifications in terms of the operation and the design of the technology. False alarms were also regarded as a sign that the ambient intelligence technology is functioning. Moreover, a good integration of the new technologies in the provision of health care is indispensable, and installation should be done in an acceptable and unobtrusive manner. Ambient intelligence technologies can contribute to an increased safety and security at home. The technologies alone offer no all encompassing solution as home care and additional environmental interventions are still needed to support ageing-in-place. Results of the study are used to further improve the ambient intelligence technologies and their implementation. 2011 Elsevier Ireland Ltd. All rights reserved.
Technology review: prototyping platforms for monitoring ambient conditions.
Afolaranmi, Samuel Olaiya; Ramis Ferrer, Borja; Martinez Lastra, Jose Luis
2018-05-08
The monitoring of ambient conditions in indoor spaces is very essential owing to the amount of time spent indoors. Specifically, the monitoring of air quality is significant because contaminated air affects the health, comfort and productivity of occupants. This research work presents a technology review of prototyping platforms for monitoring ambient conditions in indoor spaces. It involves the research on sensors (for CO 2 , air quality and ambient conditions), IoT platforms, and novel and commercial prototyping platforms. The ultimate objective of this review is to enable the easy identification, selection and utilisation of the technologies best suited for monitoring ambient conditions in indoor spaces. Following the review, it is recommended to use metal oxide sensors, optical sensors and electrochemical sensors for IAQ monitoring (including NDIR sensors for CO 2 monitoring), Raspberry Pi for data processing, ZigBee and Wi-Fi for data communication, and ThingSpeak IoT platform for data storage, analysis and visualisation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-06
... to address basic SIP requirements, including emissions inventories, monitoring, and modeling to... basic structural SIP elements such as modeling, monitoring, and emissions inventories that are designed...): Emission limits and other control measures. 110(a)(2)(B): Ambient air quality monitoring/data system. 110(a...
NASA Technical Reports Server (NTRS)
1972-01-01
An instrument for monitoring the carbon monoxide content of the ambient atmosphere is described. The subjects discussed are: (1) theory of operation, (2) system features, (3) controls and monitors, (4) operational procedures, and (5) maintenance and troubleshooting. Block drawings and circuit diagrams are included to clarify the text.
Assessment of SRS ambient air monitoring network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abbott, K.; Jannik, T.
Three methodologies have been used to assess the effectiveness of the existing ambient air monitoring system in place at the Savannah River Site in Aiken, SC. Effectiveness was measured using two metrics that have been utilized in previous quantification of air-monitoring network performance; frequency of detection (a measurement of how frequently a minimum number of samplers within the network detect an event), and network intensity (a measurement of how consistent each sampler within the network is at detecting events). In addition to determining the effectiveness of the current system, the objective of performing this assessment was to determine what, ifmore » any, changes could make the system more effective. Methodologies included 1) the Waite method of determining sampler distribution, 2) the CAP88- PC annual dose model, and 3) a puff/plume transport model used to predict air concentrations at sampler locations. Data collected from air samplers at SRS in 2015 compared with predicted data resulting from the methodologies determined that the frequency of detection for the current system is 79.2% with sampler efficiencies ranging from 5% to 45%, and a mean network intensity of 21.5%. One of the air monitoring stations had an efficiency of less than 10%, and detected releases during just one sampling period of the entire year, adding little to the overall network intensity. By moving or removing this sampler, the mean network intensity increased to about 23%. Further work in increasing the network intensity and simulating accident scenarios to further test the ambient air system at SRS is planned« less
Wireless pilot monitoring system for extreme race conditions.
Pino, Esteban J; Arias, Diego E; Aqueveque, Pablo; Melin, Pedro; Curtis, Dorothy W
2012-01-01
This paper presents the design and implementation of an assistive device to monitor car drivers under extreme conditions. In particular, this system is designed in preparation for the 2012 Atacama Solar Challenge to be held in the Chilean desert. Actual preliminary results show the feasibility of such a project including physiological and ambient sensors, real-time processing algorithms, wireless data transmission and a remote monitoring station. Implementation details and field results are shown along with a discussion of the main problems found in real-life telemetry monitoring.
78 FR 16184 - Revision to Ambient Nitrogen Dioxide Monitoring Requirements
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-14
... Revision to Ambient Nitrogen Dioxide Monitoring Requirements AGENCY: Environmental Protection Agency (EPA... ambient air quality standard (NAAQS) for nitrogen dioxide (NO 2 ) for the near-road component of the NO 2... Nitrogen Dioxide Monitoring Requirements Docket, Docket ID No. EPA-HQ-OAR-2012- 0486, EPA Docket Center...
Community Air Sensor Network (CAIRSENSE) Project: Lower Cost, Continuous Ambient Monitoring Methods
Advances in air pollution sensor technology have enabled the development of small and low cost systems to measure outdoor air pollution. The deployment of numerous sensors across a small geographic area would have potential benefits to supplement existing monitoring networks and ...
40 CFR 61.184 - Ambient air monitoring for inorganic arsenic.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard... this subpart applies shall operate a continuous monitoring system for the measurement of inorganic... operator shall submit a written plan describing, and explaining the basis for, the design and adequacy of...
40 CFR 61.184 - Ambient air monitoring for inorganic arsenic.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard... this subpart applies shall operate a continuous monitoring system for the measurement of inorganic... operator shall submit a written plan describing, and explaining the basis for, the design and adequacy of...
40 CFR 61.184 - Ambient air monitoring for inorganic arsenic.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard... this subpart applies shall operate a continuous monitoring system for the measurement of inorganic... operator shall submit a written plan describing, and explaining the basis for, the design and adequacy of...
Okeyode, I C; Rabiu, J A; Alatise, O O; Makinde, V; Akinboro, F G; Al-Azmi, D; Mustapha, A O
2017-04-01
A radiation monitoring system comprising a Geiger-Muller counter connected to a smart phone via Bluetooth was used for a dose rate survey in some parts of south-western Nigeria. The smart phone has the Geographical Positioning System, which provides the navigation information and saves it along with the dose rate data. A large number of data points was obtained that shows the dose rate distribution within the region. The results show that the ambient dose rates in the region range from 60 to 520 nSv -1 and showed a bias that is attributable to the influence of geology on the ambient radiation dose in the region. The geology influence was demonstrated by superimposing the dose rate plot and the geological map of the area. The potential applications of the device in determining baseline information and in area monitoring, e.g. for lost or abandoned sources, radioactive materials stockpiles, etc., were discussed in the article, particularly against the background of Nigeria's plan to develop its nuclear power program. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Damage detection in bridges through fiber optic structural health monitoring
NASA Astrophysics Data System (ADS)
Doornink, J. D.; Phares, B. M.; Wipf, T. J.; Wood, D. L.
2006-10-01
A fiber optic structural health monitoring (SHM) system was developed and deployed by the Iowa State University (ISU) Bridge Engineering Center (BEC) to detect gradual or sudden damage in fracture-critical bridges (FCBs). The SHM system is trained with measured performance data, which are collected by fiber optic strain sensors to identify typical bridge behavior when subjected to ambient traffic loads. Structural responses deviating from the trained behavior are considered to be signs of structural damage or degradation and are identified through analytical procedures similar to control chart analyses used in statistical process control (SPC). The demonstration FCB SHM system was installed on the US Highway 30 bridge near Ames, IA, and utilizes 40 fiber bragg grating (FBG) sensors to continuously monitor the bridge response when subjected to ambient traffic loads. After the data is collected and processed, weekly evaluation reports are developed that summarize the continuous monitoring results. Through use of the evaluation reports, the bridge owner is able to identify and estimate the location and severity of the damage. The information presented herein includes an overview of the SHM components, results from laboratory and field validation testing on the system components, and samples of the reduced and analyzed data.
40 CFR 63.820 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... were caused by a sudden, infrequent, and unavoidable failure of air pollution control and monitoring... activity or event that could have been foreseen and avoided, or planned for; and were not part of a... ambient air quality, the environment, and human health; (vi) All emissions monitoring and control systems...
40 CFR 63.820 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... were caused by a sudden, infrequent, and unavoidable failure of air pollution control and monitoring... activity or event that could have been foreseen and avoided, or planned for; and were not part of a... ambient air quality, the environment, and human health; (vi) All emissions monitoring and control systems...
40 CFR 63.820 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... were caused by a sudden, infrequent, and unavoidable failure of air pollution control and monitoring... activity or event that could have been foreseen and avoided, or planned for; and were not part of a... ambient air quality, the environment, and human health; (vi) All emissions monitoring and control systems...
Malingappa, Pandurangappa; Yarradoddappa, Venkataramanappa
2014-01-01
A new chemosensor has been used to monitor atmospheric nitrogen oxides [NO + NO2] at parts per billion (ppb) level. It is based on the catalytic reaction of nitrogen oxides with rhodamine B hydrazide (RBH) to produce a colored compound through the hydrolysis of the amide bond of the molecule. A simple colorimeter has been used to monitor atmospheric nitrogen dioxide at ppb level. The air samples were purged through a sampling cuvette containing RBH solution using peristaltic pump. The proposed method has been successfully applied to monitor the ambient nitrogen dioxide levels at traffic junction points within the city limits and the results obtained are compared with the standard Griess-Ilosvay method.
40 CFR 58.14 - System modification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 6 2012-07-01 2012-07-01 false System modification. 58.14 Section 58.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.14 System modification. (a) The State, or where...
40 CFR 58.14 - System modification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 6 2014-07-01 2014-07-01 false System modification. 58.14 Section 58.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.14 System modification. (a) The State, or where...
A Training Program in Breast Cancer Research Using NMR Techniques
2006-07-01
subtlety, and location. Both the cranio-caudal (CC) and medio -lateral oblique (MLO) projec- tion views were used. The films were digitized with a com...thermal optical monitoring system used to monitor animals’ skin temperature, ambient temper- ature, and wall temperature of the device. For imaging
AMBIENT AIR MONITORING STRATEGY
The Clean Air Act requires EPA to establish national ambient air quality standards and to regulate as necessary, hazardous air pollutants. EPA uses ambient air monitoring to determine current air quality conditions, and to assess progress toward meeting these standards and relat...
A bio-inspired structural health monitoring system based on ambient vibration
NASA Astrophysics Data System (ADS)
Lin, Tzu-Kang; Kiremidjian, Anne; Lei, Chi-Yang
2010-11-01
A structural health monitoring (SHM) system based on naïve Bayesian (NB) damage classification and DNA-like expression data was developed in this research. Adapted from the deoxyribonucleic acid (DNA) array concept in molecular biology, the proposed structural health monitoring system is constructed utilizing a double-tier regression process to extract the expression array from the structural time history recorded during external excitations. The extracted array is symbolized as the various genes of the structure from the viewpoint of molecular biology and reflects the possible damage conditions prevalent in the structure. A scaled down, six-story steel building mounted on the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark. The structural response at different damage levels and locations under ambient vibration was collected to support the database for the proposed SHM system. To improve the precision of detection in practical applications, the system was enhanced by an optimization process using the likelihood selection method. The obtained array representing the DNA array of the health condition of the structure was first evaluated and ranked. A total of 12 groups of expression arrays were regenerated from a combination of four damage conditions. To keep the length of the array unchanged, the best 16 coefficients from every expression array were selected to form the optimized SHM system. Test results from the ambient vibrations showed that the detection accuracy of the structural damage could be greatly enhanced by the optimized expression array, when compared to the original system. Practical verification also demonstrated that a rapid and reliable result could be given by the final system within 1 min. The proposed system implements the idea of transplanting the DNA array concept from molecular biology into the field of SHM.
Fiber-Optic Based Compact Gas Leak Detection System
NASA Technical Reports Server (NTRS)
deGroot, Wim A.
1995-01-01
A propellant leak detection system based on Raman scattering principles is introduced. The proposed system is flexible and versatile as the result of the use of optical fibers. It is shown that multiple species can be monitored simultaneously. In this paper oxygen, nitrogen, carbon monoxide, and hydrogen are detected and monitored. The current detection sensitivity for both hydrogen and carbon monoxide is 1% partial pressure at ambient conditions. The sensitivity for oxygen and nitrogen is 0.5% partial pressure. The response time to changes in species concentration is three minutes. This system can be used to monitor multiple species at several locations.
77 FR 45965 - Determination of Attainment for the Paul Spur/Douglas PM10
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... plans, and based on the findings of our technical system audit report, ADEQ's monitoring network meets... to EPA's Air Quality System (AQS) database as quality- assured. Next, we reviewed the ambient PM 10...
Tunca, Can; Alemdar, Hande; Ertan, Halil; Incel, Ozlem Durmaz; Ersoy, Cem
2014-01-01
Human activity recognition and behavior monitoring in a home setting using wireless sensor networks (WSNs) provide a great potential for ambient assisted living (AAL) applications, ranging from health and wellbeing monitoring to resource consumption monitoring. However, due to the limitations of the sensor devices, challenges in wireless communication and the challenges in processing large amounts of sensor data in order to recognize complex human activities, WSN-based AAL systems are not effectively integrated in the home environment. Additionally, given the variety of sensor types and activities, selecting the most suitable set of sensors in the deployment is an important task. In order to investigate and propose solutions to such challenges, we introduce a WSN-based multimodal AAL system compatible for homes with multiple residents. Particularly, we focus on the details of the system architecture, including the challenges of sensor selection, deployment, networking and data collection and provide guidelines for the design and deployment of an effective AAL system. We also present the details of the field study we conducted, using the systems deployed in two different real home environments with multiple residents. With these systems, we are able to collect ambient sensor data from multiple homes. This data can be used to assess the wellbeing of the residents and identify deviations from everyday routines, which may be indicators of health problems. Finally, in order to elaborate on the possible applications of the proposed AAL system and to exemplify directions for processing the collected data, we provide the results of several human activity inference experiments, along with examples on how such results could be interpreted. We believe that the experiences shared in this work will contribute towards accelerating the acceptance of WSN-based AAL systems in the home setting. PMID:24887044
Tunca, Can; Alemdar, Hande; Ertan, Halil; Incel, Ozlem Durmaz; Ersoy, Cem
2014-05-30
Human activity recognition and behavior monitoring in a home setting using wireless sensor networks (WSNs) provide a great potential for ambient assisted living (AAL) applications, ranging from health and wellbeing monitoring to resource consumption monitoring. However, due to the limitations of the sensor devices, challenges in wireless communication and the challenges in processing large amounts of sensor data in order to recognize complex human activities, WSN-based AAL systems are not effectively integrated in the home environment. Additionally, given the variety of sensor types and activities, selecting the most suitable set of sensors in the deployment is an important task. In order to investigate and propose solutions to such challenges, we introduce a WSN-based multimodal AAL system compatible for homes with multiple residents. Particularly, we focus on the details of the system architecture, including the challenges of sensor selection, deployment, networking and data collection and provide guidelines for the design and deployment of an effective AAL system. We also present the details of the field study we conducted, using the systems deployed in two different real home environments with multiple residents. With these systems, we are able to collect ambient sensor data from multiple homes. This data can be used to assess the wellbeing of the residents and identify deviations from everyday routines, which may be indicators of health problems. Finally, in order to elaborate on the possible applications of the proposed AAL system and to exemplify directions for processing the collected data, we provide the results of several human activity inference experiments, along with examples on how such results could be interpreted. We believe that the experiences shared in this work will contribute towards accelerating the acceptance of WSN-based AAL systems in the home setting.
Novel Approaches for Estimating Human Exposure to Air Pollutants
Numerous health studies have used measurements from a few central-site ambient monitors to characterize air pollution exposures. Relying on solely on central-site ambient monitors does not account for the spatial-heterogeneity of ambient air pollution patterns, the temporal varia...
Malingappa, Pandurangappa; Yarradoddappa, Venkataramanappa
2014-01-01
A new chemosensor has been used to monitor atmospheric nitrogen oxides [NO + NO2] at parts per billion (ppb) level. It is based on the catalytic reaction of nitrogen oxides with rhodamine B hydrazide (RBH) to produce a colored compound through the hydrolysis of the amide bond of the molecule. A simple colorimeter has been used to monitor atmospheric nitrogen dioxide at ppb level. The air samples were purged through a sampling cuvette containing RBH solution using peristaltic pump. The proposed method has been successfully applied to monitor the ambient nitrogen dioxide levels at traffic junction points within the city limits and the results obtained are compared with the standard Griess-Ilosvay method. PMID:25210422
High-resolution motion-compensated imaging photoplethysmography for remote heart rate monitoring
NASA Astrophysics Data System (ADS)
Chung, Audrey; Wang, Xiao Yu; Amelard, Robert; Scharfenberger, Christian; Leong, Joanne; Kulinski, Jan; Wong, Alexander; Clausi, David A.
2015-03-01
We present a novel non-contact photoplethysmographic (PPG) imaging system based on high-resolution video recordings of ambient reflectance of human bodies that compensates for body motion and takes advantage of skin erythema fluctuations to improve measurement reliability for the purpose of remote heart rate monitoring. A single measurement location for recording the ambient reflectance is automatically identified on an individual, and the motion for the location is determined over time via measurement location tracking. Based on the determined motion information motion-compensated reflectance measurements at different wavelengths for the measurement location can be acquired, thus providing more reliable measurements for the same location on the human over time. The reflectance measurement is used to determine skin erythema fluctuations over time, resulting in the capture of a PPG signal with a high signal-to-noise ratio. To test the efficacy of the proposed system, a set of experiments involving human motion in a front-facing position were performed under natural ambient light. The experimental results demonstrated that skin erythema fluctuations can achieve noticeably improved average accuracy in heart rate measurement when compared to previously proposed non-contact PPG imaging systems.
Pope, Larry M.; Rosner, Stacy M.; Hoffman, Darren C.; Ziegler, Andrew C.
2004-01-01
The investigation described in this report summarized data from State ambient stream-water-quality monitoring sites for 10 water-quality constituents or measurements (suspended solids, fecal coliform bacteria, ammonia as nitrogen, nitrite plus nitrate as nitrogen, total phosphorus, total arsenic, dissolved solids, chloride, sulfate, and pH). These 10 water-quality constituents or measurements commonly are listed nationally as major contributors to degradation of surface water. Water-quality data were limited to that electronically accessible from the U.S. Environmental Protection Agency Storage and Retrieval System (STORET), the U.S. Geological Survey National Water Information System (NWIS), or individual State databases. Forty-two States had ambient stream-water-quality data electronically accessible for some or all of the constituents or measurements summarized during this investigation. Ambient in this report refers to data collected for the purpose of evaluating stream ecosystems in relation to human health, environmental and ecological conditions, and designated uses. Generally, data were from monitoring sites assessed for State 305(b) reports. Comparisons of monitoring data among States are problematic for several reasons, including differences in the basic spatial design of monitoring networks; water-quality constituents for which samples are analyzed; water-quality criteria to which constituent concentrations are compared; quantity and comprehensiveness of water-quality data; sample collection, processing, and handling; analytical methods; temporal variability in sample collection; and quality-assurance practices. Large differences among the States in number of monitoring sites precluded a general assumption that statewide water-quality conditions were represented by data from these sites. Furthermore, data from individual monitoring sites may not represent water-quality conditions at the sites because sampling conditions and protocols are unknown. Because of these factors, a high level of uncertainty exists in a national assessment of water quality. The purpose of this report is to present a summary of electronically available State ambient stream-water-quality data for 10 selected constituents and measurements from monitoring sites with nine or more analyses for 199098 and to discuss limitations for use of the data for national assessment. These analyses were statistiscally summarized by monitoring site and State, and the results presented in tabular format. Most of the selected constituents or measurements have U.S. Environmental Protection Agency criteria or guidelines for aquatic-life or drinking-water purposes. A significant finding of this investigation is that for a large percentage of monitoring sites in the Nation, there are insufficient data to meet U.S. Environmental Protection Agency recommendations for determining if water-quality conditions are degraded and for making informed decisions regarding total maximum daily loads.
The drift velocity monitoring system of the CMS barrel muon chambers
NASA Astrophysics Data System (ADS)
Altenhöfer, Georg; Hebbeker, Thomas; Heidemann, Carsten; Reithler, Hans; Sonnenschein, Lars; Teyssier, Daniel
2018-04-01
The drift velocity is a key parameter of drift chambers. Its value depends on several parameters: electric field, pressure, temperature, gas mixture, and contamination, for example, by ambient air. A dedicated Velocity Drift Chamber (VDC) with 1-L volume has been built at the III. Phys. Institute A, RWTH Aachen, in order to monitor the drift velocity of all CMS barrel muon Drift Tube chambers. A system of six VDCs was installed at CMS and has been running since January 2011. We present the VDC monitoring system, its principle of operation, and measurements performed.
Energy harvesting schemes for building interior environment monitoring
NASA Astrophysics Data System (ADS)
Zylka, Pawel; Pociecha, Dominik
2016-11-01
A vision to supply microelectronic devices without batteries making them perpetual or extending time of service in battery-oriented mobile supply schemes is the driving force of the research related to ambient energy harvesting. Energy harnessing aims thus at extracting energy from various ambient energy "pools", which generally are cost- or powerineffective to be scaled up for full-size, power-plant energy generation schemes supplying energy in electric form. These include - but are not limited to - waste heat, electromagnetic hum, vibrations, or human-generated power in addition to traditional renewable energy resources like water flow, tidal and wind energy or sun radiation which can also be exploited at the miniature scale by energy scavengers. However, in case of taking advantage of energy harvesting strategies to power up sensors monitoring environment inside buildings adaptable energy sources are restrained to only some which additionally are limited in spatial and temporal accessibility as well as available power. The paper explores experimentally an energy harvesting scheme exploiting human kinesis applicable in indoor environment for supplying a wireless indoor micro-system, monitoring ambient air properties (pressure, humidity and temperature).
Ambient Assisted Nutritional Advisor for elderly people living at home.
Lazaro, Juan P; Fides, Alvaro; Navarro, Ana; Guillen, Sergio
2010-01-01
Nutrition is a critical aspect when getting older because bad nutrition habits can accelerate the process of degradation of the physical condition of the old person. In order to mitigate this problem, an Ambient Assisted Living service has been developed. Research with this service is focused on demonstrating that with an Ambient Intelligence systems it is possible to make the nutritional management much more effective by influencing the user, by automatically and seamlessly monitoring and by facilitating tools for nutritional management for people that want to be autonomous. In this paper both requirement acquisition and development processes are described as well.
Morris, G J
2009-01-01
A simple assay to monitor the potential for contamination during different steps of cryopreservation is described. The assay is based on the contamination of liquid nitrogen using crystals of sucrose hemi-heptahydrate, these are stable in liquid nitrogen, nitrogen vapour and ambient air and can be monitored by a simple assay which allows contamination risks to be evaluated in a direct, rapid manner.
Ambient multi-perceptive system with electronic mail for a residential health monitoring system.
Noury, N; Villemazet, C; Fleury, A; Barralon, P; Rumeau, P; Vuillerme, N; Baghai, R
2006-01-01
Based on several years of experiments, we propose a model of information systems for residential healthcare, and technical guide to select available hard and software technologies. An implementation is described, based on Emails. The system is under experimentation within the framework of the French national project AILISA.
Linking Meteorology, Air Quality Models and Observations to ...
Epidemiologic studies are critical in establishing the association between exposure to air pollutants and adverse health effects. Results of epidemiologic studies are used by U.S. EPA in developing air quality standards to protect the public from the health effects of air pollutants. A major challenge in environmental epidemiology is adequate exposure characterization. Numerous health studies have used measurements from a few central-site ambient monitors to characterize air pollution exposures. Relying solely on central-site ambient monitors does not account for the spatial-heterogeneity of ambient air pollution patterns, the temporal variability in ambient concentrations, nor the influence of infiltration and indoor sources. Central-site monitoring becomes even more problematic for certain air pollutants that exhibit significant spatial heterogeneity. Statistical interpolation techniques and passive monitoring methods can provide additional spatial resolution in ambient concentration estimates. In addition, spatio-temporal models, which integrate GIS data and other factors, such as meteorology, have also been developed to produce more resolved estimates of ambient concentrations. Models, such as the Community Multi-Scale Air Quality (CMAQ) model, estimate ambient concentrations by combining information on meteorology, source emissions, and chemical-fate and transport. Hybrid modeling approaches, which integrate regional scale models with local scale dispersion
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-07
..., and modeling to assure attainment and maintenance for that new NAAQS. Section 110(a) of the CAA... structural SIP requirements such as modeling, monitoring, and emissions inventories that are designed to... limits and other control measures. 110(a)(2)(B): Ambient air quality monitoring/data system. 110(a)(2)(C...
EPA through statutory mandates has monitored air, water, land and human health for the past several decades. The design of the ambient air monitoring networks, for the most part, has been loosely tied single-pollutant networks focused on large urban areas. These networks supply t...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-24
... recorded in EPA's Air Quality System (AQS) database. To account for missing data, the procedures found in... three-year period and then adjusts for missing data. In short, if the three-year average expected... ambient air quality monitoring data for the 2001-2003 monitoring period showing that the area had an...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-14
... ambient air quality monitoring data for the period preceding the applicable attainment deadline. DATES... and certified monitoring data. A violation occurs when the ambient ozone air quality monitoring data... standard, generally based on air quality monitoring data from the 1987 through 1989 period (section 107(d...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... based on complete, quality-assured and certified ambient air quality monitoring data for 2007-2009... certain air quality monitoring data because they meet the criteria for ozone exceptional events that are... certified monitoring data. A violation occurs when the ambient ozone air quality monitoring data show...
Assessment of ambient air quality in Eskişehir, Turkey.
Ozden, O; Döğeroğlu, T; Kara, S
2008-07-01
This paper presents an assessment of air quality of the city Eskişehir, located 230 km southwest to the capital of Turkey. Only five of the major air pollutants, most studied worldwide and available for the region, were considered for the assessment. Available sulphur dioxide (SO(2)), particulate matter (PM), nitrogen dioxide (NO(2)), ozone (O(3)), and non-methane volatile organic carbons (NMVOCs) data from local emission inventory studies provided relative source contributions of the selected pollutants to the region. The contributions of these typical pollution parameters, selected for characterizing such an urban atmosphere, were compared with the data established for other cities in the nation and world countries. Additionally, regional ambient SO(2) and PM concentrations, determined by semi-automatic monitoring at two sites, were gathered from the National Ambient Air Monitoring Network (NAAMN). Regional data for ambient NO(2) (as a precursor of ozone as VOCs) and ozone concentrations, through the application of the passive sampling method, were provided by the still ongoing local air quality monitoring studies conducted at six different sites, as representatives of either the traffic-dense-, or coal/natural gas burning residential-, or industrial/rural-localities of the city. Passively sampled ozone data at a single rural site were also verified with the data from a continuous automatic ozone monitoring system located at that site. Effects of variations in seasonal-activities, newly established railway system, and switching to natural gas usage on the temporal changes of air quality were all considered for the assessment. Based on the comparisons with the national [AQCR (Air Quality Control Regulation). Ministry of Environment (MOE), Ankara. Official Newspaper 19269; 1986.] and a number of international [WHO (World Health Organization). Guidelines for Air Quality. Geneva; 2000. Downloaded in January 2006, website: http://www.who.int/peh/; EU (European Union). Council Directive 1999/30/EC relating to limit values for sulfur dioxide, nitrogen dioxide and lead in ambient air. Of J Eur Communities L 163: 14-30; 29.6.1999; EU (European Union). Council Directive 2002/3/EC relating to ozone in ambient air. Of J Eur Communities. L 67: 14-30; 9.3.2002.; USEPA (U.S. Environmental Protection Agency). National Ambient Air Quality Standards (NAAQS). Downloaded in January 2006, website: http://www.epa.gov/ttn/naaqs/] ambient air standards, among all the pollutants studied, only the annual average SO(2) concentration was found to exceed one specific limit value (EU limit for protection of the ecosystem). A part of the data (VOC/NO(x) ratio), for determining the effects of photochemical interactions, indicated that VOC-limited regime was prevailing throughout the city.
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture
Marques, Gonçalo; Pitarma, Rui
2016-01-01
The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants’ wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment. PMID:27869682
An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture.
Marques, Gonçalo; Pitarma, Rui
2016-11-17
The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants' wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-29
...\\ EPA also concluded \\8\\ from its Technical System Audit of the BAAQMD Primary Quality Assurance..., Air Pollution Control Officer, BAAQMD, transmitting ``System Audit of the Ambient Monitoring Program... email. www.regulations.gov is an ``anonymous access'' system, and EPA will not know your identity or...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-30
...\\ Furthermore, we concluded in our Technical System Audit Report concerning ADEQ's ambient air quality... Monitoring Network Plan: For the Year 2011''). \\7\\ Technical System Audit Report transmitted via... an ``anonymous access'' system, and EPA will not know your identity or contact information unless you...
Ambient lighting: setting international standards for the viewing of softcopy chest images
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Ryan, John; Evanoff, Micheal G.; Keeling, Aoife; Chakraborty, Dev; Manning, David; Brennan, Patrick C.
2007-03-01
Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and <10 Lux. All monitors were calibrated to DICOM part 14 GSDF. Sixty radiologists were presented with 30 chest images, 15 images having simulated nodular lesions of varying subtlety and size. Lesions were positioned in accordance with typical clinical presentation and were validated radiologically. Each image was presented for 30 seconds and viewers were asked to identify and score any visualized lesion from 1-4 to indicate confidence level of detection. At the end of the session, sensitivity and specificity were calculated. Analysis of the data suggests that visualization of chest lesions is affected by inappropriate lighting with chest radiologists demonstrating greater ambient lighting dependency. JAFROC analyses are currently being performed.
NASA Astrophysics Data System (ADS)
Baxter, Lisa K.; Clougherty, Jane E.; Paciorek, Christopher J.; Wright, Rosalind J.; Levy, Jonathan I.
Previous studies have identified associations between traffic-related air pollution and adverse health effects. Most have used measurements from a few central ambient monitors and/or some measure of traffic as indicators of exposure, disregarding spatial variability and factors influencing personal exposure-ambient concentration relationships. This study seeks to utilize publicly available data (i.e., central site monitors, geographic information system, and property assessment data) and questionnaire responses to predict residential indoor concentrations of traffic-related air pollutants for lower socioeconomic status (SES) urban households. As part of a prospective birth cohort study in urban Boston, we collected indoor and outdoor 3-4 day samples of nitrogen dioxide (NO 2) and fine particulate matter (PM 2.5) in 43 low SES residences across multiple seasons from 2003 to 2005. Elemental carbon (EC) concentrations were determined via reflectance analysis. Multiple traffic indicators were derived using Massachusetts Highway Department data and traffic counts collected outside sampling homes. Home characteristics and occupant behaviors were collected via a standardized questionnaire. Additional housing information was collected through property tax records, and ambient concentrations were collected from a centrally located ambient monitor. The contributions of ambient concentrations, local traffic and indoor sources to indoor concentrations were quantified with regression analyses. PM 2.5 was influenced less by local traffic but had significant indoor sources, while EC was associated with traffic and NO 2 with both traffic and indoor sources. Comparing models based on covariate selection using p-values or a Bayesian approach yielded similar results, with traffic density within a 50 m buffer of a home and distance from a truck route as important contributors to indoor levels of NO 2 and EC, respectively. The Bayesian approach also highlighted the uncertanity in the models. We conclude that by utilizing public databases and focused questionnaire data we can identify important predictors of indoor concentrations for multiple air pollutants in a high-risk population.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-11
... Methods: Designation of a New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of a new equivalent method for monitoring ambient air quality. SUMMARY: Notice is... part 53, a new equivalent method for measuring concentrations of PM 2.5 in the ambient air. FOR FURTHER...
METHODOLOGY FOR SITING AMBIENT AIR MONITORS AT THE NEIGHBORHOOD SCALE
In siting a monitor to measure compliance with U.S. National Ambient Air Quality Standards for particulate matter (PM), there is a need to characterize variations in PM concentration within a neighborhood-scale region in order to achieve monitor siting objectives.
We p...
Coherent ambient infrasound recorded by the International Monitoring System
NASA Astrophysics Data System (ADS)
Matoza, Robin S.; LandèS, Matthieu; Le Pichon, Alexis; Ceranna, Lars; Brown, David
2013-01-01
The ability of the International Monitoring System (IMS) infrasound network to detect atmospheric nuclear explosions and other signals of interest is strongly dependent on station-specific ambient noise. This ambient noise includes both incoherent wind noise and real coherent infrasonic waves. Previous ambient infrasound noise models have not distinguished between incoherent and coherent components. We present a first attempt at statistically and systematically characterizing coherent infrasound recorded by the IMS. We perform broadband (0.01-5 Hz) array processing with the IMS continuous waveform archive (39 stations from 1 April 2005 to 31 December 2010) using an implementation of the Progressive Multi-Channel Correlation algorithm in log-frequency space. From these results, we estimate multi-year 5th, 50th, and 95th percentiles of the RMS pressure of coherent signals in 15 frequency bands for each station. We compare the resulting coherent infrasound models with raw power spectral density noise models, which inherently include both incoherent and coherent components. Our results indicate that IMS arrays consistently record coherent ambient infrasound across the broad frequency range from 0.01 to 5 Hz when wind noise levels permit. The multi-year averaging emphasizes continuous signals such as oceanic microbaroms, as well as persistent transient signals such as repetitive volcanic, surf, thunder, or anthropogenic activity. Systematic characterization of coherent infrasound detection is important for quantifying a station's recording environment, signal-to-noise ratio as a function of frequency and direction, and overall performance, which all influence the detection probability of specific signals of interest.
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
Quality aspects of digital radiography in general dental practice.
Hellén-Halme, Kristina
2007-01-01
The number of dentists who have converted from conventional film radiography to digital radiography continues to grow. A digital system has numerous advantages, but there are also many new aspects to consider. The overall aim of this thesis was to study how digital radiography was used in general dental practices. The specific aims were to study how different factors affected image quality. To determine whether there were any differences in image quality between conventional film radiographs and digital radiographs, 4863 images (540 cases) were evaluated. The cases had been sent to the Swedish Dental Insurance Office for prior treatment approval. The image quality of digital radiographs was found to be significantly lower than that of film radiographs. This result led to a questionnaire study of dentists experienced in digital radiography. In 2003, a questionnaire was sent to the 139 general practice dentists who worked with digital radiography in Skine, Sweden; the response rate was 94%. Many general practice dentists had experienced several problems (65%), and less than half of the digital systems (40%) underwent some kind of quality control. One of the weaker links in the technical chain of digital radiography appeared to be the monitor. A field study to 19 dentists at their clinics found that the brightness and contrast settings of the monitors had to be adjusted to obtain the subjectively best image quality. The ambient light in the evaluation room was also found to affect the diagnostic outcome of low-contrast patterns in radiographs. To evaluate the effects of ambient light and technical adjustments of the monitor, a study using standardised set-ups was designed. Seven observers evaluated radiographs of 100 extracted human teeth for approximal caries under five different combinations of brightness and contrast settings on two different occasions with high and low ambient light levels in the evaluation room. The ability to diagnose carious lesions was found to be significantly better in a room with lower ambient light and on a monitor with well-adjusted brightness and contrast values than in a room with bright light and on an unadjusted monitor. In conclusion, many problems with dental digital radiography were identified. Knowledge of digital techniques and how to optimise each link in the system to maintain high radiographic quality at all times must be improved.
NASA Astrophysics Data System (ADS)
Cho, Sunny; Vijayaraghavan, Krish; Spink, David; Cosic, Biljana; Davies, Mervyn; Jung, Jaegun
2017-11-01
A study was undertaken to determine whether, and the extent to which, increased ground-level ozone (O3) precursor emissions from oil sands development have impacted ambient air quality in the north-eastern Alberta, Canada, over the period 1998 to 2012. Temporal trends in emissions of O3 precursors (NOx and VOC) and ambient air concentrations of O3 precursors, and O3 were examined using the Theil-Sen statistical analysis method. Statistically significant correlations between NOx emissions and ambient NOx concentrations were found mainly near surface (open-pit) mining areas where mine fleets are a large source of NOx emissions. No statistically significant trends in the 4th highest daily maximum 8-hr average O3 at any of the continuous and passive ambient air monitoring stations were found. A significant long-term decrease in monthly averaged O3 is observed at some ambient monitoring sites in summer. A visual examination of long-term variations in annual NOx and VOC emissions and annual 4th highest daily maximum 8-hr O3 concentrations does not reveal any indication of a correlation between O3 concentrations and O3 precursor emissions or ambient levels in the study area. Despite a significant increase in oil sands NOx emissions (8%/yr), there is no statistically significant increase in long-term O3 concentrations at any of monitoring stations considered. This suggests that there is surplus NOx available in the environment which results in a titration of ambient O3 in the areas that have ambient monitoring. The limited ambient O3 monitoring data distant from NOx emission sources makes it impossible to assess the impact of these increased O3 precursor levels on O3 levels on a regional scale. As a precautionary measure, the increasing oil sands development O3 precursor emissions would require that priority be given to the management of these emissions to prevent possible future O3 ambient air quality issues.
NASA Astrophysics Data System (ADS)
Hashimoto, Atsushi; Suehara, Ken-Ichiro; Kameoka, Takaharu
To measure the quantitative surface color information of agricultural products with the ambient information during cultivation, a color calibration method for digital camera images and a remote monitoring system of color imaging using the Web were developed. Single-lens reflex and web digital cameras were used for the image acquisitions. The tomato images through the post-ripening process were taken by the digital camera in both the standard image acquisition system and in the field conditions from the morning to evening. Several kinds of images were acquired with the standard RGB color chart set up just behind the tomato fruit on a black matte, and a color calibration was carried out. The influence of the sunlight could be experimentally eliminated, and the calibrated color information consistently agreed with the standard ones acquired in the system through the post-ripening process. Furthermore, the surface color change of the tomato on the tree in a greenhouse was remotely monitored during maturation using the digital cameras equipped with the Field Server. The acquired digital color images were sent from the Farm Station to the BIFE Laboratory of Mie University via VPN. The time behavior of the tomato surface color change during the maturing process could be measured using the color parameter calculated based on the obtained and calibrated color images along with the ambient atmospheric record. This study is a very important step in developing the surface color analysis for both the simple and rapid evaluation of the crop vigor in the field and to construct an ambient and networked remote monitoring system for food security, precision agriculture, and agricultural research.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-03
... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR part 53, one new equivalent method for measuring concentrations of lead (Pb) in total...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-07
... Monitoring Reference and Equivalent Methods; Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR Part 53, one new equivalent method for measuring concentrations of ozone (O 3 ) in the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-18
... Monitoring Reference and Equivalent Methods: Designation of Two New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of two new equivalent methods for monitoring ambient air... accordance with 40 CFR Part 53, two new equivalent methods for measuring concentrations of PM 10 and sulfur...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-27
... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR Part 53, one new equivalent method for measuring concentrations of ozone (O 3 ) in the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR Part 53, one new equivalent method for measuring concentrations of lead (Pb) in total...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-04
... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR part 53, one new equivalent method for measuring concentrations of lead (Pb) in total...
Effects of temperature on bridge dynamic properties : final report.
DOT National Transportation Integrated Search
2015-12-01
Structural health monitoring (SHM) using ambient vibration has become a valuable tool in : evaluating and assessing the condition of civil structures. For bridge structures, a vibrationbased : SHM system uses the dynamic response of a bridge to measu...
Hands-On Experiences in Deploying Cost-Effective Ambient-Assisted Living Systems
Dasios, Athanasios; Gavalas, Damianos; Pantziou, Grammati; Konstantopoulos, Charalampos
2015-01-01
Older adults’ preferences to remain independent in their own homes along with the high costs of nursing home care have motivated the development of Ambient Assisted Living (AAL) technologies which aim at improving the safety, health conditions and wellness of the elderly. This paper reports hands-on experiences in designing, implementing and operating UbiCare, an AAL based prototype system for elderly home care monitoring. The monitoring is based on the recording of environmental parameters like temperature and light intensity as well as micro-level incidents which allows one to infer daily activities like moving, sitting, sleeping, usage of electrical appliances and plumbing components. The prototype is built upon inexpensive, off-the-shelf hardware (e.g., various sensors, Arduino microcontrollers, ZigBee-compatible wireless communication modules) and license-free software, thereby ensuring low system deployment costs. The network comprises nodes placed in a house’s main rooms or mounted on furniture, one wearable node, one actuator node and a centralized processing element (coordinator). Upon detecting significant deviations from the ordinary activity patterns of individuals and/or sudden falls, the system issues automated alarms which may be forwarded to authorized caregivers via a variety of communication channels. Furthermore, measured environmental parameters and activity incidents may be monitored through standard web interfaces. PMID:26094631
Hands-On Experiences in Deploying Cost-Effective Ambient-Assisted Living Systems.
Dasios, Athanasios; Gavalas, Damianos; Pantziou, Grammati; Konstantopoulos, Charalampos
2015-06-18
Older adults' preferences to remain independent in their own homes along with the high costs of nursing home care have motivated the development of Ambient Assisted Living (AAL) technologies which aim at improving the safety, health conditions and wellness of the elderly. This paper reports hands-on experiences in designing, implementing and operating UbiCare, an AAL based prototype system for elderly home care monitoring. The monitoring is based on the recording of environmental parameters like temperature and light intensity as well as micro-level incidents which allows one to infer daily activities like moving, sitting, sleeping, usage of electrical appliances and plumbing components. The prototype is built upon inexpensive, off-the-shelf hardware (e.g., various sensors, Arduino microcontrollers, ZigBee-compatible wireless communication modules) and license-free software, thereby ensuring low system deployment costs. The network comprises nodes placed in a house's main rooms or mounted on furniture, one wearable node, one actuator node and a centralized processing element (coordinator). Upon detecting significant deviations from the ordinary activity patterns of individuals and/or sudden falls, the system issues automated alarms which may be forwarded to authorized caregivers via a variety of communication channels. Furthermore, measured environmental parameters and activity incidents may be monitored through standard web interfaces.
Real-time alpha monitoring of a radioactive liquid waste stream at Los Alamos National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, J.D.; Whitley, C.R.; Rawool-Sullivan, M.
1995-12-31
This poster display concerns the development, installation, and testing of a real-time radioactive liquid waste monitor at Los Alamos National Laboratory (LANL). The detector system was designed for the LANL Radioactive Liquid Waste Treatment Facility so that influent to the plant could be monitored in real time. By knowing the activity of the influent, plant operators can better monitor treatment, better segregate waste (potentially), and monitor the regulatory compliance of users of the LANL Radioactive Liquid Waste Collection System. The detector system uses long-range alpha detection technology, which is a nonintrusive method of characterization that determines alpha activity on themore » liquid surface by measuring the ionization of ambient air. Extensive testing has been performed to ensure long-term use with a minimal amount of maintenance. The final design was a simple cost-effective alpha monitor that could be modified for monitoring influent waste streams at various points in the LANL Radioactive Liquid Waste Collection System.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... data upon which to base national assessments and policy decisions. ... ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Method development estimating ambient mercury concentration from monitored mercury wet deposition
NASA Astrophysics Data System (ADS)
Chen, S. M.; Qiu, X.; Zhang, L.; Yang, F.; Blanchard, P.
2013-05-01
Speciated atmospheric mercury data have recently been monitored at multiple locations in North America; but the spatial coverage is far less than the long-established mercury wet deposition network. The present study describes a first attempt linking ambient concentration with wet deposition using Beta distribution fitting of a ratio estimate. The mean, median, mode, standard deviation, and skewness of the fitted Beta distribution parameters were generated using data collected in 2009 at 11 monitoring stations. Comparing the normalized histogram and the fitted density function, the empirical and fitted Beta distribution of the ratio shows a close fit. The estimated ambient mercury concentration was further partitioned into reactive gaseous mercury and particulate bound mercury using linear regression model developed by Amos et al. (2012). The method presented here can be used to roughly estimate mercury ambient concentration at locations and/or times where such measurement is not available but where wet deposition is monitored.
NASA Astrophysics Data System (ADS)
Zimmermann, R.; Bente, M.; Sklorz, M.
2007-12-01
Polycyclic aromatic hydrocarbons (PAH) are formed as trace products in combustion processes and are emitted to the atmosphere. Larger PAH have low vapour pressure and are predominantly bound to the ambient fine particulate matter (PM). Upon inhalation, PAH show both, chronic human toxicity (i.e. many PAH are potent carcinogens) as well as acute human toxicity (i.e. inflammatory effects due to oxi-dative stress) and are discussed to be relevant for the observed health effect of ambient PM. Therefore a better understanding of the occurrence, dynamics and particle size dependence of particle bound-PAH is of great interest. On-line aerosol mass spectrometry in principle is the method of choice to investigate the size resolved changes in the chemical speciation of particles as well the status of internal vs. external mixing of chemical constituents. However the present available aerosol mass spectrometers (ATOFMS and AMS) do not allow detection of PAH from ambient air PM. In order to allow a single particle based monitoring of PAH from ambient PM a new single particle laser ionisation mass spectrometer was built and applied. The system is based on ATOFMS principle but uses a two- step photo-ionization. A tracked and sized particle firstly is laser desorbed (LD) by a IR-laser pulse (CO2-laser, λ=10.2 μm) and subsequently the released PAH are selectively ionized by an intense UV-laser pulse (ArF excimer, λ=248 nm) in a resonance enhanced multiphoton ionisation process (REMPI). The PAH-ions are detected in a time of flight mass spectrometer (TOFMS). A virtual impactor enrichment unit is used to increase the detection frequency of the ambient particles. With the current inlet system particles from about 400 nm to 10 μm are accessible. Single particle based temporal profiles of PAH containing particles ion (size distribution and PAH speciation) have been recorded in Oberschleissheim, Germany from ambient air. Furthermore profiles of relevant emission sources (e.g. gasoline and diesel engine, wood combustion) and the obtained chemical profiles were compared with the ones from the ambient PAH containing particles.
Progress in ambient assisted systems for independent living by the elderly.
Al-Shaqi, Riyad; Mourshed, Monjur; Rezgui, Yacine
2016-01-01
One of the challenges of the ageing population in many countries is the efficient delivery of health and care services, which is further complicated by the increase in neurological conditions among the elderly due to rising life expectancy. Personal care of the elderly is of concern to their relatives, in case they are alone in their homes and unforeseen circumstances occur, affecting their wellbeing. The alternative; i.e. care in nursing homes or hospitals is costly and increases further if specialized care is mobilized to patients' place of residence. Enabling technologies for independent living by the elderly such as the ambient assisted living systems (AALS) are seen as essential to enhancing care in a cost-effective manner. In light of significant advances in telecommunication, computing and sensor miniaturization, as well as the ubiquity of mobile and connected devices embodying the concept of the Internet of Things (IoT), end-to-end solutions for ambient assisted living have become a reality. The premise of such applications is the continuous and most often real-time monitoring of the environment and occupant behavior using an event-driven intelligent system, thereby providing a facility for monitoring and assessment, and triggering assistance as and when needed. As a growing area of research, it is essential to investigate the approaches for developing AALS in literature to identify current practices and directions for future research. This paper is, therefore, aimed at a comprehensive and critical review of the frameworks and sensor systems used in various ambient assisted living systems, as well as their objectives and relationships with care and clinical systems. Findings from our work suggest that most frameworks focused on activity monitoring for assessing immediate risks, while the opportunities for integrating environmental factors for analytics and decision-making, in particular for the long-term care were often overlooked. The potential for wearable devices and sensors, as well as distributed storage and access (e.g. cloud) are yet to be fully appreciated. There is a distinct lack of strong supporting clinical evidence from the implemented technologies. Socio-cultural aspects such as divergence among groups, acceptability and usability of AALS were also overlooked. Future systems need to look into the issues of privacy and cyber security.
Ambient Intelligence in a Smart Home for Energy Efficiency and Eldercare
NASA Astrophysics Data System (ADS)
de Silva, Liyanage C.; Petra, M. Iskandar; Punchihewa, G. Amal
In this paper we present our research results related to smart monitoring, control and communication with the main objective of energy efficiency and eldercare in mind. One of the main objectives of this research work is to use multitude of different sensors to monitor activities in a smart home and use the results to control the home environment to meet the objectives of energy efficiency and eldercare. Here we present the application of the smart monitoring to a prototype system.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-30
...\\ from its Technical System Audit of the CARB PQAO (conducted during the summer of 2007) that the ambient... email. www.regulations.gov is an ``anonymous access'' system, and EPA will not know your identity or... PM 2.5 NAAQS based on 2009-2011 monitoring data. Preliminary data in EPA's Air Quality System (AQS...
Towards a smart non-invasive fluid loss measurement system.
Suryadevara, N K; Mukhopadhyay, S C; Barrack, L
2015-04-01
In this article, a smart wireless sensing non-invasive system for estimating the amount of fluid loss, a person experiences while physical activity is presented. The system measures three external body parameters, Heart Rate, Galvanic Skin Response (GSR, or skin conductance), and Skin Temperature. These three parameters are entered into an empirically derived formula along with the user's body mass index, and estimation for the amount of fluid lost is determined. The core benefit of the developed system is the affluence usage in combining with smart home monitoring systems to care elderly people in ambient assisted living environments as well in automobiles to monitor the body parameters of a motorist.
A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention
De Paz, Juan F.; Barriuso, Alberto L.
2018-01-01
Context-aware monitoring systems designed for e-Health solutions and ambient assisted living (AAL) play an important role in today’s personalized health-care services. The majority of these systems are intended for the monitoring of patients’ vital signs by means of bio-sensors. At present, there are very few systems that monitor environmental conditions and air quality in the homes of users. A home’s environmental conditions can have a significant influence on the state of the health of its residents. Monitoring the environment is the key to preventing possible diseases caused by conditions that do not favor health. This paper presents a context-aware system that monitors air quality to prevent a specific health problem at home. The aim of this system is to reduce the incidence of the Sudden Infant Death Syndrome, which is triggered mainly by environmental factors. In the conducted case study, the system monitored the state of the neonate and the quality of air while it was asleep. The designed proposal is characterized by its low cost and non-intrusive nature. The results are promising. PMID:29498653
A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention.
De La Iglesia, Daniel H; De Paz, Juan F; Villarrubia González, Gabriel; Barriuso, Alberto L; Bajo, Javier
2018-03-02
Context-aware monitoring systems designed for e-Health solutions and ambient assisted living (AAL) play an important role in today's personalized health-care services. The majority of these systems are intended for the monitoring of patients' vital signs by means of bio-sensors. At present, there are very few systems that monitor environmental conditions and air quality in the homes of users. A home's environmental conditions can have a significant influence on the state of the health of its residents. Monitoring the environment is the key to preventing possible diseases caused by conditions that do not favor health. This paper presents a context-aware system that monitors air quality to prevent a specific health problem at home. The aim of this system is to reduce the incidence of the Sudden Infant Death Syndrome, which is triggered mainly by environmental factors. In the conducted case study, the system monitored the state of the neonate and the quality of air while it was asleep. The designed proposal is characterized by its low cost and non-intrusive nature. The results are promising.
From intensive care monitoring to personal health monitoring to ambient intelligence.
Rienhoff, Otto
2013-01-01
The historical roots of IT-based monitoring in health care are described. Since the 1970ies monitoring has been spreading to more and more domains of health care and public health. Today one can observe monitoring of persons in many environments and regarding widely different questions. While these monitoring applications have been introduced ethical questions have been raised to balance the possible positive and negative outcomes of the approaches. Today IT-technology is entering many parts of our life - IT eventually became what had been coined already in the last century by IBM as "electronic dust" which one can find in every part of our environment. As most of these "dust-particles" are able to observe something one can also understand this development as a development into ubiquitous monitoring of nearly everything at any time. The foreseen ambient intelligence worlds are also spaces of ambient monitoring. This article describes this historical development. It emphasizes why ethical and data protection questions are an absolute must in most IT activities today.
NASA Astrophysics Data System (ADS)
Anton, S. R.; Taylor, S. G.; Raby, E. Y.; Farinholt, K. M.
2013-03-01
With a global interest in the development of clean, renewable energy, wind energy has seen steady growth over the past several years. Advances in wind turbine technology bring larger, more complex turbines and wind farms. An important issue in the development of these complex systems is the ability to monitor the state of each turbine in an effort to improve the efficiency and power generation. Wireless sensor nodes can be used to interrogate the current state and health of wind turbine structures; however, a drawback of most current wireless sensor technology is their reliance on batteries for power. Energy harvesting solutions present the ability to create autonomous power sources for small, low-power electronics through the scavenging of ambient energy; however, most conventional energy harvesting systems employ a single mode of energy conversion, and thus are highly susceptible to variations in the ambient energy. In this work, a multi-source energy harvesting system is developed to power embedded electronics for wind turbine applications in which energy can be scavenged simultaneously from several ambient energy sources. Field testing is performed on a full-size, residential scale wind turbine where both vibration and solar energy harvesting systems are utilized to power wireless sensing systems. Two wireless sensors are investigated, including the wireless impedance device (WID) sensor node, developed at Los Alamos National Laboratory (LANL), and an ultra-low power RF system-on-chip board that is the basis for an embedded wireless accelerometer node currently under development at LANL. Results indicate the ability of the multi-source harvester to successfully power both sensors.
NASA Astrophysics Data System (ADS)
Picozzi, M.; Milkereit, C.; Zulfikar, C.; Ditommaso, R.; Erdik, M.; Safak, E.; Fleming, K.; Ozel, O.; Zschau, J.; Apaydin, N.
2008-12-01
The monitoring of strategic civil infrastructures to ensure their structural integrity is a task of major importance, especially in earthquake-prone areas. Classical approaches to such monitoring are based on visual inspections and the use of wired systems. While the former has the drawback that the structure is only superficially examined and discontinuously in time, wired systems are relatively expensive and time consuming to install. Today, however, wireless systems represent an advanced, easily installed and operated tool to be used for monitoring purposes, resulting in a wide and interesting range of possible applications. Within the framework of the earthquake early warning projects SAFER (Seismic eArly warning For EuRope) and EDIM (Earthquake Disaster Information systems for the Marmara Sea region, Turkey), new low-cost wireless sensors with the capability to automatically rearrange their communications scheme are being developed. The reduced sensitivity of these sensors, arising from the use of low-cost components, is compensated by the possibility of deploying high-density self-organizing networks performing real-time data acquisition and analysis. Thanks to the developed system's versatility, it has been possible to perform an experimental ambient vibration test with a network of 24 sensors on the Fatih Sultan Mehmet Bridge, Istanbul (Turkey), a gravity-anchored suspension bridge spanning the Bosphorus Strait with distance between its towers of 1090 m. Preliminary analysis of the data has demonstrated that the main modal properties of the bridge can be retrieved, and may therefore be regularly re-evaluated as part of a long-term monitoring program. Using a multi-hop communications technique, data could be exchanged among groups of sensors over distances of a few hundred meters. Thus, the test showed that, although more work is required to optimize the communication parameters, the performance of the network offers encouragement for us to follow this research direction in developing wireless systems for the monitoring of civil infrastructures.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-01
... missing data, the procedures in appendix H to 40 CFR part 50 are used to adjust the actual number of..., quality-assured and certified ambient air quality monitoring data for 2003 through 2005. In addition, EPA... and certified ambient air monitoring data showing the area has monitored attainment of the 1-hour...
Report #09-P-0087, January 27, 2009. EPA has progressed in implementing the counter terrorism/emergency response (CT/ER) initiatives, but is behind schedule in implementing the Radiation Ambient Monitoring (RadNet) System.
40 CFR 52.582 - Control strategy: Ozone.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.582 Section 52.582 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED...—The Administrator approves the incorporation of the photochemical assessment ambient monitoring system...
Code of Federal Regulations, 2014 CFR
2014-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Code of Federal Regulations, 2011 CFR
2011-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Code of Federal Regulations, 2013 CFR
2013-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Code of Federal Regulations, 2012 CFR
2012-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-27
... anonymous access system, and EPA will not know your identity or contact information unless you provide it in... control measures. Section 110(a)(2)(B): Ambient air quality monitoring/data system. Section 110(a)(2)(C... significant deterioration (PSD) and visibility protection. Section 110(a)(2)(K): Air quality modeling and...
Definition of air quality measurements for monitoring space shuttle launches
NASA Technical Reports Server (NTRS)
Thorpe, R. D.
1978-01-01
A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.
Ali, Mahboob; Athar, Makshoof
2008-01-01
Transportation system has contributed significantly to the development of human civilization; on the other hand it has an enormous impact on the ambient air quality in several ways. In this paper the air and noise pollution at selected sites along three sections of National Highway was monitored. Pakistan National Highway Authority has started a Highway Improvement program for rehabilitations and maintenance of National highways to improve the traffic flows, and would ultimately improve the air quality along highways. The ambient air quality and noise level was monitored at nine different locations along these sections of highways to quantify the air pollution. The duration of monitoring at individual location was 72 h. The most of the sampling points were near the urban or village population, schools or hospitals, in order to quantify the air pollution at most affected locations along these roads. A database consisting of information regarding the source of emission, local metrology and air quality may be created to assess the profile of air quality in the area.
The National Ambient Air Monitoring Stategy: Rethinking the Role of National Networks
A current re-engineering of the United States routine ambient monitoring networks intended to improve the balance in addressing both regulatory and scientific objectives is addressed in this paper. Key attributes of these network modifications include the addition of collocated ...
The deployment of carbon monoxide wireless sensor network (CO-WSN) for ambient air monitoring.
Chaiwatpongsakorn, Chaichana; Lu, Mingming; Keener, Tim C; Khang, Soon-Jai
2014-06-16
Wireless sensor networks are becoming increasingly important as an alternative solution for environment monitoring because they can reduce cost and complexity. Also, they can improve reliability and data availability in places where traditional monitoring methods are difficult to site. In this study, a carbon monoxide wireless sensor network (CO-WSN) was developed to measure carbon monoxide concentrations at a major traffic intersection near the University of Cincinnati main campus. The system has been deployed over two weeks during Fall 2010, and Summer 2011-2012, traffic data was also recorded by using a manual traffic counter and a video camcorder to characterize vehicles at the intersection 24 h, particularly, during the morning and evening peak hour periods. According to the field test results, the 1 hr-average CO concentrations were found to range from 0.1-1.0 ppm which is lower than the National Ambient Air Quality Standards (NAAQS) 35 ppm on a one-hour averaging period. During rush hour periods, the traffic volume at the intersection varied from 2,067 to 3,076 vehicles per hour with 97% being passenger vehicles. Furthermore, the traffic volume based on a 1-h average showed good correlation (R2 = 0.87) with the 1-h average CO-WSN concentrations for morning and evening peak time periods whereas CO-WSN results provided a moderate correlation (R2 = 0.42) with 24 hours traffic volume due to fluctuated changes of meteorological conditions. It is concluded that the performance and the reliability of wireless ambient air monitoring networks can be used as an alternative method for real time air monitoring.
NASA Astrophysics Data System (ADS)
Noh, Hae Young; Kiremidjian, Anne S.
2011-04-01
This paper introduces a data compression method using the K-SVD algorithm and its application to experimental ambient vibration data for structural health monitoring purposes. Because many damage diagnosis algorithms that use system identification require vibration measurements of multiple locations, it is necessary to transmit long threads of data. In wireless sensor networks for structural health monitoring, however, data transmission is often a major source of battery consumption. Therefore, reducing the amount of data to transmit can significantly lengthen the battery life and reduce maintenance cost. The K-SVD algorithm was originally developed in information theory for sparse signal representation. This algorithm creates an optimal over-complete set of bases, referred to as a dictionary, using singular value decomposition (SVD) and represents the data as sparse linear combinations of these bases using the orthogonal matching pursuit (OMP) algorithm. Since ambient vibration data are stationary, we can segment them and represent each segment sparsely. Then only the dictionary and the sparse vectors of the coefficients need to be transmitted wirelessly for restoration of the original data. We applied this method to ambient vibration data measured from a four-story steel moment resisting frame. The results show that the method can compress the data efficiently and restore the data with very little error.
ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements
NASA Technical Reports Server (NTRS)
Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.;
2009-01-01
ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.
Ambient Vibration Testing for Story Stiffness Estimation of a Heritage Timber Building
Min, Kyung-Won; Kim, Junhee; Park, Sung-Ah; Park, Chan-Soo
2013-01-01
This paper investigates dynamic characteristics of a historic wooden structure by ambient vibration testing, presenting a novel estimation methodology of story stiffness for the purpose of vibration-based structural health monitoring. As for the ambient vibration testing, measured structural responses are analyzed by two output-only system identification methods (i.e., frequency domain decomposition and stochastic subspace identification) to estimate modal parameters. The proposed methodology of story stiffness is estimation based on an eigenvalue problem derived from a vibratory rigid body model. Using the identified natural frequencies, the eigenvalue problem is efficiently solved and uniquely yields story stiffness. It is noteworthy that application of the proposed methodology is not necessarily confined to the wooden structure exampled in the paper. PMID:24227999
A UAV-Mounted Whole Cell Biosensor System for Environmental Monitoring Applications
Lu, Yi; Macias, Dominique; Dean, Zachary S.; Kreger, Nicole R.; Wong, Pak Kin
2016-01-01
This study reports the development of a portable whole cell biosensor system for environmental monitoring applications, such as air quality control, water pollution monitoring and radiation leakage detection. The system consists of a lightweight mechanical housing, a temperature regulating system, and a microfluidic bacterial inoculation channel. The overall system, which is less than 200 g, serves as a portable incubator for cell inoculation and can be mounted on an unmanned aerial vehicle for monitoring remote and unreachable locations. The feedback control system maintains the inoculation temperature within 0.05 degree Celsius. The large surface-to-volume ratio of the polydimethylsiloxane microchannel facilitates effective gas exchange for rapid bacterial growth. Molecular dynamic simulation shows effective diffusion of major gas pollutants in PDMS toward gas sensing applications. By optimizing the design, we demonstrate the operation of the system in ambient temperatures from 5°C to 32°C and rapid bacterial growth in microchannels compared to standard bacterial culture techniques. PMID:26584498
The open literature, Federal publications, industrial reports, and other sources published between 1975 and 1980 were reviewed for information relevant to personal air samplers potentially useful in sampling organic compounds at ambient levels (50-200 ppt). Seventy one references...
Epidemiological analyses of air quality often estimate human exposure from ambient monitoring data, potentially leading to exposure misclassification and subsequent bias in estimated health risks. To investigate this, we conducted a case-crossover study of summertime ambient ozon...
Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources
NASA Technical Reports Server (NTRS)
Ding, Leibo; Kowalewski, Matthew G.; Cooper, John W.; Smith, GIlbert R.; Barnes, Robert A.; Waluschka, Eugene; Butler, James J.
2011-01-01
The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.
NASA Astrophysics Data System (ADS)
Del Gaudio, Vincenzo; Wasowski, Janusz
2016-04-01
In the last few decades, we have witnessed a growing awareness of the role of site dynamic response to seismic shaking in slope failures during earthquakes. Considering the time and costs involved in acquiring accelerometer data on landslide prone slopes, the analysis of ambient noise offers a profitable investigative alternative. Standard procedures of ambient noise analysis, according to the technique known as HVNR or Nakamura's method, were originally devised to interpret data under simple site conditions similar to 1D layering (flat horizontal layering infinitely extended). In such cases, conditions of site amplification, characterized by a strong impedance contrast between a soft surface layer and a stiff bedrock, result in a single pronounced isotropic maximum of spectral ratios between horizontal and vertical component of ambient noise. However, previous studies have shown that the dynamic response of slopes affected by landslides is rather complex, being characterized by multiple resonance peaks with directional variability, thus, the use of standard techniques can encounter difficulties in providing reliable information. A new approach of data analysis has recently been proposed to exploit the potential of information content of Rayleigh waves present in ambient noise, with regard to the identification of frequency and orientation of directional resonance. By exploiting ground motion ellipticity this approach can also provide information on vertical distribution of S-wave velocity, which controls site amplification factors. The method, based on the identification of Rayleigh wave packets from instantaneous polarization properties of ambient noise, was first tested using synthetic signals in order to optimize the data processing system. Then the improved processing scheme is adopted to re-process and re-interpret the ambient noise data acquired on landslide prone slopes around Caramanico Terme (central Italy), at sites monitored also with accelerometer stations. The comparison of ambient noise analysis results with the outcomes of accelerometer monitoring reveals potential and limits of the new method for the investigations on slope dynamic response.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maisel, B.E.; Hunt, G.T.; Devaney, R.J. Jr.
EPA`s Brownfields Economic Redevelopment Initiative has sparked renewal of industrial and commercial parcels otherwise idled or under-utilized because of real or perceived environmental contamination. In certain cases, restoring such parcels to productive economic use requires a redevelopment effort protective of human health and welfare through minimizing offsite migration of environmental contaminants during cleanup, demolition and remediation activities. To support these objectives, an air monitoring program is often required as an integral element of a comprehensive brownfields redevelopment effort. This paper presents a strategic framework for design and execution of an ambient air monitoring program in support of a brownfields remediationmore » effort ongoing in Lawrence, MA. Based on site characterization, the program included sample collection and laboratory analysis of ambient air samples for polychlorinated biphenyls (PCBs), polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs/PCDFs), total suspended particulate (TSP), inhalable particulate (PM10), and lead. The program included four monitoring phases, identified as background, wintertime, demolition/remediation and post-demolition. Air sampling occurred over a 16 month period during 1996--97, during which time nine sampling locations were utilized to produce approximately 1,500 ambient air samples. Following strict data review and validation procedures, ambient air data interpretation focused on the following: evaluation of upwind/downwind sample pairs, comparison of ambient levels to existing regulatory standards, relation of ambient levels to data reported in the open literature, and, determination of normal seasonal variations in existing background burden, comparison of ambient levels measured during site activity to background levels.« less
Evaluation of the semi-continuous Monitor for Aerosols and Gases in Ambient Air (MARGA, Metrohm Applikon B.V.) was conducted with an emphasis on examination of accuracy and precision associated with processing of chromatograms. Using laboratory standards and atmospheric measureme...
A source apportionment study was conducted to identify sources within a large elemental phosphorus plant that contribute to exceedances of the National Ambient Air Quality Standard for 24-h PM10. Ambient data were collected at three monitoring sites from October 1996 through Ju...
The U.S. EPA National Exposure Research Laboratory (NERL) collaborated with EPA's Regional offices to establish a monitoring network to characterize ambient air concentrations of particulate matter (PM) and air toxics in lower Manhattan following the collapse of the World Trade...
Filtration effectiveness of HVAC systems at near-roadway schools.
McCarthy, M C; Ludwig, J F; Brown, S G; Vaughn, D L; Roberts, P T
2013-06-01
Concern for the exposure of children attending schools located near busy roadways to toxic, traffic-related air pollutants has raised questions regarding the environmental benefits of advanced heating, ventilation, and air-conditioning (HVAC) filtration systems for near-road pollution. Levels of black carbon and gaseous pollutants were measured at three indoor classroom sites and at seven outdoor monitoring sites at Las Vegas schools. Initial HVAC filtration systems effected a 31-66% reduction in black carbon particle concentrations inside three schools compared with ambient air concentrations. After improved filtration systems were installed, black carbon particle concentrations were reduced by 74-97% inside three classrooms relative to ambient air concentrations. Average black carbon particle concentrations inside the schools with improved filtration systems were lower than typical ambient Las Vegas concentrations by 49-96%. Gaseous pollutants were higher indoors than outdoors. The higher indoor concentrations most likely originated at least partially from indoor sources, which were not targeted as part of this intervention. Recent literature has demonstrated adverse health effects in subjects exposed to ambient air near major roadways. Current smart growth planning and infill development often require that buildings such as schools are built near major roadways. Improving the filtration systems of a school's HVAC system was shown to decrease children's exposure to near-roadway diesel particulate matter. However, reducing exposure to the gas-phase air toxics, which primarily originated from indoor sources, may require multiple filter passes on recirculated air. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
[Open-path online monitoring of ambient atmospheric CO2 based on laser absorption spectrum].
He, Ying; Zhang, Yu-Jun; Kan, Rui-Feng; Xia, Hui; Geng, Hui; Ruan, Jun; Wang, Min; Cui, Xiao-Juan; Liu, Wen-Qing
2009-01-01
With the conjunction of tunable diode laser absorption spectroscopy technology (TDLAS) and the open long optical path technology, the system designing scheme of CO2 on-line monitoring based on near infrared tunable diode laser absorption spectroscopy technology was discussed in detail, and the instrument for large-range measurement was set up. By choosing the infrared absorption line of CO2 at 1.57 microm whose line strength is strong and suitable for measurement, the ambient atmospheric CO2 was measured continuously with a 30 s temporal resolution at an suburb site in the autumn of 2007. The diurnal atmospheric variations of CO2 and continuous monitoring results were presented. The results show that the variation in CO2 concentration has an obvious diurnal periodicity in suburb where the air is free of interference and contamination. The general characteristic of diurnal variation is that the concentration is low in the daytime and high at night, so it matches the photosynthesis trend. The instrument can detect gas concentration online with high resolution, high sensitivity, high precision, short response time and many other advantages, the monitoring requires no gas sampling, the calibration is easy, and the detection limit is about 4.2 x 10(-7). It has been proved that the system and measurement project are feasible, so it is an effective method for gas flux continuous online monitoring of large range in ecosystem based on TDLAS technology.
Operational Modal Analysis of Bridge Structures with Data from GNSS/Accelerometer Measurements.
Xiong, Chunbao; Lu, Huali; Zhu, Jinsong
2017-02-23
Real-time dynamic displacement and acceleration responses of the main span section of the Tianjin Fumin Bridge in China under ambient excitation were tested using a Global Navigation Satellite System (GNSS) dynamic deformation monitoring system and an acceleration sensor vibration test system. Considering the close relationship between the GNSS multipath errors and measurement environment in combination with the noise reduction characteristics of different filtering algorithms, the researchers proposed an AFEC mixed filtering algorithm, which is an combination of autocorrelation function-based empirical mode decomposition (EMD) and Chebyshev mixed filtering to extract the real vibration displacement of the bridge structure after system error correction and filtering de-noising of signals collected by the GNSS. The proposed AFEC mixed filtering algorithm had high accuracy (1 mm) of real displacement at the elevation direction. Next, the traditional random decrement technique (used mainly for stationary random processes) was expanded to non-stationary random processes. Combining the expanded random decrement technique (RDT) and autoregressive moving average model (ARMA), the modal frequency of the bridge structural system was extracted using an expanded ARMA_RDT modal identification method, which was compared with the power spectrum analysis results of the acceleration signal and finite element analysis results. Identification results demonstrated that the proposed algorithm is applicable to analyze the dynamic displacement monitoring data of real bridge structures under ambient excitation and could identify the first five orders of the inherent frequencies of the structural system accurately. The identification error of the inherent frequency was smaller than 6%, indicating the high identification accuracy of the proposed algorithm. Furthermore, the GNSS dynamic deformation monitoring method can be used to monitor dynamic displacement and identify the modal parameters of bridge structures. The GNSS can monitor the working state of bridges effectively and accurately. Research results can provide references to evaluate the bearing capacity, safety performance, and durability of bridge structures during operation.
Operational Modal Analysis of Bridge Structures with Data from GNSS/Accelerometer Measurements
Xiong, Chunbao; Lu, Huali; Zhu, Jinsong
2017-01-01
Real-time dynamic displacement and acceleration responses of the main span section of the Tianjin Fumin Bridge in China under ambient excitation were tested using a Global Navigation Satellite System (GNSS) dynamic deformation monitoring system and an acceleration sensor vibration test system. Considering the close relationship between the GNSS multipath errors and measurement environment in combination with the noise reduction characteristics of different filtering algorithms, the researchers proposed an AFEC mixed filtering algorithm, which is an combination of autocorrelation function-based empirical mode decomposition (EMD) and Chebyshev mixed filtering to extract the real vibration displacement of the bridge structure after system error correction and filtering de-noising of signals collected by the GNSS. The proposed AFEC mixed filtering algorithm had high accuracy (1 mm) of real displacement at the elevation direction. Next, the traditional random decrement technique (used mainly for stationary random processes) was expanded to non-stationary random processes. Combining the expanded random decrement technique (RDT) and autoregressive moving average model (ARMA), the modal frequency of the bridge structural system was extracted using an expanded ARMA_RDT modal identification method, which was compared with the power spectrum analysis results of the acceleration signal and finite element analysis results. Identification results demonstrated that the proposed algorithm is applicable to analyze the dynamic displacement monitoring data of real bridge structures under ambient excitation and could identify the first five orders of the inherent frequencies of the structural system accurately. The identification error of the inherent frequency was smaller than 6%, indicating the high identification accuracy of the proposed algorithm. Furthermore, the GNSS dynamic deformation monitoring method can be used to monitor dynamic displacement and identify the modal parameters of bridge structures. The GNSS can monitor the working state of bridges effectively and accurately. Research results can provide references to evaluate the bearing capacity, safety performance, and durability of bridge structures during operation. PMID:28241472
Development of a cloud-based system for remote monitoring of a PVT panel
NASA Astrophysics Data System (ADS)
Saraiva, Luis; Alcaso, Adérito; Vieira, Paulo; Ramos, Carlos Figueiredo; Cardoso, Antonio Marques
2016-10-01
The paper presents a monitoring system developed for an energy conversion system based on the sun and known as thermophotovoltaic panel (PVT). The project was implemented using two embedded microcontrollers platforms (arduino Leonardo and arduino yún), wireless transmission systems (WI-FI and XBEE) and net computing ,commonly known as cloud (Google cloud). The main objective of the project is to provide remote access and real-time data monitoring (like: electrical current, electrical voltage, input fluid temperature, output fluid temperature, backward fluid temperature, up PV glass temperature, down PV glass temperature, ambient temperature, solar radiation, wind speed, wind direction and fluid mass flow). This project demonstrates the feasibility of using inexpensive microcontroller's platforms and free internet service in theWeb, to support the remote study of renewable energy systems, eliminating the acquisition of dedicated systems typically more expensive and limited in the kind of processing proposed.
Different relationships between personal exposure and ambient concentration by particle size.
Guak, Sooyoung; Lee, Kiyoung
2018-04-06
Ambient particulate matter (PM) concentrations at monitoring stations were often used as an indicator of population exposure to PM in epidemiological studies. The correlation between personal exposure and ambient concentrations of PM varied because of diverse time-activity patterns. The aim of this study was to determine the relationship between personal exposure and ambient concentrations of PM 10 and PM 2.5 with minimal impact of time-activity pattern on personal exposure. Performance of the MicroPEM, v3.2 was evaluated by collocation with central ambient air monitors for PM 10 and PM 2.5 . A field technician repeatedly conducted measurement of 24 h personal exposures to PM 10 and PM 2.5 with a fixed time-activity pattern of office worker over 26 days in Seoul, Korea. The relationship between the MicroPEM and the ambient air monitor showed good linearity. Personal exposure and ambient concentrations of PM 2.5 were highly correlated with a fixed time-activity pattern compared with PM 10 . The finding implied a high infiltration rate of PM 2.5 and low infiltration rate of PM 10 . The relationship between personal exposure and ambient concentrations of PM 10 and PM 2.5 was different for high level episodes. In the Asian dust episode, staying indoors could reduce personal exposure to PM 10 . However, personal exposure to PM 2.5 could not be reduced by staying indoors during the fine dust advisory episode.
Ambient Air Quality Data Inventory
The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as state, local, and tribal air pollution control agencies. Its component data sets have been collected over the years from approximately 10,000 monitoring sites, of which approximately 5,000 are currently active. OAR's Office of Air Quality Planning and Standards (OAQPS) and other internal and external users, rely on this data to assess air quality, assist in Attainment/Non-Attainment designations, evaluate State Implementation Plans for Non-Attainment Areas, perform modeling for permit review analysis, and other air quality management functions. Air quality information is also used to prepare reports for Congress as mandated by the Clean Air Act. This data covers air quality data collected after 1980, when the Clean Air Act requirements for monitoring were significantly modified. Air quality data from the Agency's early years (1970s) remains available (see OAR PRIMARY DATA ASSET: Ambient Air Quality Data -- Historical), but because of technical and definitional differences the two data assets are not directly comparable. The Clean Air Act of 1970 provided initial authority for monitoring air quality for Conventional Air Pollutants (CAPs) for which EPA has promulgated National Ambient Air Quality Standards (NAAQS). Requirements for monitoring visibility-related parameters were added in 1977. Requiremen
Reduced Healthcare Use and Apparent Savings with Passive Home Monitoring Technology: A Pilot Study.
Finch, Michael; Griffin, Kristen; Pacala, James T
2017-06-01
To conduct a cost analysis of ambient assisted living technology, which is promising for improving the ability of individuals and care providers to monitor daily activities and gain better awareness through proactive management of health and safety. Three-arm cohort study. Homes of enrollees of a state-based healthcare plan for older adults. Enrollees dually eligible for Medicare and Medicaid (N = 268). Health and safety passive remote patient monitoring (PRPM) systems were installed in enrollees' homes (the intervention group) with monitoring and proactive intervention of a case manager when deviation from baseline subject behavior was detected. Claims data were collected over 12 months to assess healthcare use and costs in the intervention group and to compare use and costs with those of two control groups: a concurrent group of enrollees who declined the technology and a historical cohort matched on age to the participation group. Although the small sample size precluded cost differences that were statistically significant, the participant group used substantially less custodial care, emergency department (ED) services, inpatient stays, and ED costs than the two control groups. In this pilot study, the PRPM system was associated with apparent healthcare cost savings. Although more cost analyses are warranted, ambient assisted living technologies are a potentially valuable investment for older adult care. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.
NATIONAL COW MILK SURVEY FOR PERSISTENT, BIOACCUMULATIVE AND TOXIC (PBT) POLLUTANTS
This is a survey for persistent, bioaccumulative, and toxic (PBT) pollutants in the U.S. milk supply. The EPA Environmental Radiation Ambient Monitoring System (ERAMS) was used to collect two sets of milk samples, one set in July 2000 and the second in January 2001. ERAMS has abo...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-05
... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of three new equivalent methods for monitoring ambient air quality. SUMMARY... equivalent methods, one for measuring concentrations of PM 2.5 , one for measuring concentrations of PM 10...
40 CFR 50.14 - Treatment of air quality monitoring data influenced by exceptional events.
Code of Federal Regulations, 2010 CFR
2010-07-01
... specific air pollution concentration at a particular air quality monitoring location. (2) Demonstration to... exceptional event caused a specific air pollution concentration in excess of one or more national ambient air... specific air pollution concentration in excess of one or more national ambient air quality standards at a...
The semi-continuous Monitor for AeRosols and Gases in Ambient air (MARGA) was evaluated using laboratory and field data with a focus on chromatography. The performance and accuracy assessment revealed various errors and uncertainties resulting from mis-identification and mis-int...
Ambient air quality has traditionally been monitored using a network of fixed point sampling sites that are strategically placed to represent regional (e.g., county or town) rather than local (e.g., neighborhood) air quality trends. This type of monitoring data has been used to m...
The semi-continuous Monitor for AeRosols and Gases in Ambient air (MARGA) was evaluated using laboratory and field data with a focus on chromatography. The performance and accuracy assessment revealed various errors and uncertainties resulting from mis-identification and mis-int...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-07
... techniques, provisions for the establishment and operation of appropriate devices necessary to collect data... information.) Ambient air quality monitoring data for the 3-year period must meet a data completeness requirement. The ambient air quality monitoring data completeness requirement is met when the percent of days...
Ambient air spiked with 1-10 ppbv concentrations of 41 toxic volatile organic compounds (VOCs) listed in U.S. Environmental Protection Agency (EPA) Compendium Method TO-14A was monitored using solid sorbents for sample collection and a Varian Saturn 2000 ion trap mass spectrome...
ESUMS: a mobile system for continuous home monitoring of rehabilitation patients.
Strisland, Frode; Svagård, Ingrid; Seeberg, Trine M; Mathisen, Bjørn Magnus; Vedum, Jon; Austad, Hanne O; Liverud, Anders E; Kofod-Petersen, Anders; Bendixen, Ole Christian
2013-01-01
The pressure on the healthcare services is building up for several reasons. The ageing population trend, the increase in life-style related disease prevalence, as well as the increased treatment capabilities with associated general expectation all add pressure. The use of ambient healthcare technologies can alleviate the situation by enabling time and cost-efficient monitoring and follow-up of patients discharged from hospital care. We report on an ambulatory system developed for monitoring of physical rehabilitation patients. The system consists of a wearable multisensor monitoring device; a mobile phone with client application aggregating the data collected; a service-oriented-architecture based server solution; and a PC application facilitating patient follow-up by their health professional carers. The system has been tested and verified for accuracy in controlled environment trials on healthy volunteers, and also been usability tested by 5 congestive heart failure patients and their nurses. This investigation indicated that patients were able to use the system, and that nurses got an improved basis for patient follow-up.
Structural Monitoring and Field Test for Kao Ping Hsi Cable-Stayed Bridge in Taiwan
NASA Astrophysics Data System (ADS)
Chen, Chern-Hwa
2010-05-01
This work applies system identification techniques to analyze the measured data from structural monitoring system and field test for Kao Ping Hsi cable-stayed bridge in Taiwan. The continuous wavelet transform algorithm can be used to identify the dynamic characteristics of the cable-stayed bridge under environmental vibration. The identified results with traffic flow were compared with those obtained from ambient vibration test. The excellent agreement both the identified results from different traffic conditions indicates that the traffic flow would not significantly change the natural frequencies of the cable-stayed bridge. The modal parameters identified from the field vibration test will be compared with those used in the finite element analysis. The results obtained herein will be used as the damage detection for monitoring the long-term safety of the Kao Ping Hsi cable-stayed bridge by using structural monitoring system.
NASA Astrophysics Data System (ADS)
Joseph, Erouscilla P.; Beckles, Denise M.; Cox, Leonette; Jackson, Viveka B.; Alexander, Dominic
2015-10-01
Sulphur Springs Park in Saint Lucia is a site of energetic geothermal activity associated with the potentially active Soufrière Volcanic Centre. The Park is one of Saint Lucia's most important tourist attractions, and is marketed as the 'world's only drive-in volcano'. It has an on-site staff of tour guides and vendors, as well as over 200,000 visitors annually. There are also a number of residents living in the areas bordering the Park. Recreational use is made of the geothermal waters for bathing, application of mud masques, and in some cases drinking. As part of the University of the West Indies, Seismic Research Centre's (UWI-SRC's) overall volcano monitoring programme for Saint Lucia, the volcanic emissions at Sulphur Springs (hot springs, mud pools and fumaroles) have been regularly monitored since 2001. In recent years, visitors, staff, and management at the Park have expressed concern about the health effects of exposure to volcanic emissions from the hydrothermal system. In response to this, SRC has expanded its regular geothermal monitoring programme to include a preliminary evaluation of ambient sulphur dioxide (SO2) concentrations in and around the Park, to assess the possible implications for human health. Passive diffusion tubes were used to measure the atmospheric SO2 concentrations at various sites in Sulphur Springs Park (SSP), in the town of Soufrière and in the capital of Castries. Measurements of average monthly ambient SO2 with the passive samplers indicated that during the dry season period of April to July 2014 concentration at sites closest to the main vents at SSP (Group 1), which are routinely used by staff and visitors, frequently exceeded the WHO 10-minute AQG for SO2 of 500 μg/m3. However, for sites that were more distal to the main venting area (Groups 2 and 3), the average monthly ambient SO2 did not exceed the WHO 10-minute AQG for SO2 of 500 μg/m3 during the entire monitoring period. The measured concentrations and dispersion patterns of ambient SO2 at SSP appear to be influenced by rainfall, proximity to the fumarolic vents, altitude (local topography), local atmospheric circulation and plume dispersion, and anthropogenic sources. Brochures and posters were prepared, for public distribution and display, on possible gas hazards that may be encountered at SSP and precautionary measures that may be taken by visitors to help minimise potential risk from elevated exposure to volcanic gases.
Computation of structural flexibility for bridge health monitoring using ambient modal data
DOT National Transportation Integrated Search
1996-01-01
The issues surrounding the use of ambient vibration modes for the location of structural damage via dynamically : measured flexibility are examined. Several methods for obtaining the required mass-normalized : dynamic mode shapes from ambient modal d...
Uokawa, Y; Yonezawa, Y; Caldwell, W M; Hahn, A W
2000-01-01
A data acquisition system employing a low power 8 bit microcomputer has been developed for heart rate variability monitoring before, during and after bathing. The system consists of three integral chest electrodes, two temperature sensors, an instrumentation amplifier, a low power 8-bit single chip microcomputer (SMC) and a 4 MB compact flash memory (CFM). The ECG from the electrodes is converted to an 8-bit digital format at a 1 ms rate by an A/D converter in the SMC. Both signals from the body and ambient temperature sensors are converted to an 8-bit digital format every 1 second. These data are stored by the CFM. The system is powered by a rechargeable 3.6 V lithium battery. The 4 x 11 x 1 cm system is encapsulated in epoxy and silicone, yielding a total volume of 44 cc. The weight is 100 g.
The Deployment of Carbon Monoxide Wireless Sensor Network (CO-WSN) for Ambient Air Monitoring
Chaiwatpongsakorn, Chaichana; Lu, Mingming; Keener, Tim C.; Khang, Soon-Jai
2014-01-01
Wireless sensor networks are becoming increasingly important as an alternative solution for environment monitoring because they can reduce cost and complexity. Also, they can improve reliability and data availability in places where traditional monitoring methods are difficult to site. In this study, a carbon monoxide wireless sensor network (CO-WSN) was developed to measure carbon monoxide concentrations at a major traffic intersection near the University of Cincinnati main campus. The system has been deployed over two weeks during Fall 2010, and Summer 2011–2012, traffic data was also recorded by using a manual traffic counter and a video camcorder to characterize vehicles at the intersection 24 h, particularly, during the morning and evening peak hour periods. According to the field test results, the 1 hr-average CO concentrations were found to range from 0.1–1.0 ppm which is lower than the National Ambient Air Quality Standards (NAAQS) 35 ppm on a one-hour averaging period. During rush hour periods, the traffic volume at the intersection varied from 2,067 to 3,076 vehicles per hour with 97% being passenger vehicles. Furthermore, the traffic volume based on a 1-h average showed good correlation (R2 = 0.87) with the 1-h average CO-WSN concentrations for morning and evening peak time periods whereas CO-WSN results provided a moderate correlation (R2 = 0.42) with 24 hours traffic volume due to fluctuated changes of meteorological conditions. It is concluded that the performance and the reliability of wireless ambient air monitoring networks can be used as an alternative method for real time air monitoring. PMID:24937527
The Research Triangle Park particulate matter panel study: PM mass concentration relationships
NASA Astrophysics Data System (ADS)
Williams, Ron; Suggs, Jack; Rea, Anne; Leovic, Kelly; Vette, Alan; Croghan, Carry; Sheldon, Linda; Rodes, Charles; Thornburg, Jonathan; Ejire, Ademola; Herbst, Margaret; Sanders, William
The US Environmental Protection Agency has recently performed the Research Triangle Park Particulate Matter Panel Study. This was a 1-year investigation of PM and related co-pollutants involving participants living within the RTP area of North Carolina. Primary goals were to characterize the relationships between ambient and residential PM measures to those obtained from personal exposure monitoring and estimate ambient source contributions to personal and indoor mass concentrations. A total of 38 participants living in 37 homes were involved in personal, residential indoor, residential outdoor and ambient PM 2.5 exposure monitoring. Participants were 30 non-smoking hypertensive African-Americans living in a low-moderate SES neighborhood (SE Raleigh, NC) and a cohort of eight individuals having implanted cardiac defibrillators (Chapel Hill, NC). Residential and ambient monitoring of PM 10 and PM 10-2.5 (coarse by differential) was also performed. The volunteers were monitored for seven consecutive days during each of four seasons (summer 2000, fall 2000, winter 2001, spring 2001). Individual PM 2.5 personal exposure concentrations ranged from 4 to 218 μg m -3 during the study. The highest personal exposures were determined to be the result of passive environmental tobacco exposures. Subsequently, ˜7% of the total number of personal exposure trials were excluded to minimize this pollutant's effect upon the overall analysis. Results indicated that a pooled data set (seasons, cohorts, residences, participants) was appropriate for investigation of the basic mass concentration relationships. Daily personal PM 2.5 mass concentrations were typically higher than their associated residential or ambient measurements (mean personal=23.0, indoor=19.1, outdoor=19.3, ambient=19.2 μg m -3). Mean personal PM 2.5 exposures were observed to be only moderately correlated to ambient PM 2.5 concentrations ( r=0.39).
2014-01-01
Background Exposure measurement error is a concern in long-term PM2.5 health studies using ambient concentrations as exposures. We assessed error magnitude by estimating calibration coefficients as the association between personal PM2.5 exposures from validation studies and typically available surrogate exposures. Methods Daily personal and ambient PM2.5, and when available sulfate, measurements were compiled from nine cities, over 2 to 12 days. True exposure was defined as personal exposure to PM2.5 of ambient origin. Since PM2.5 of ambient origin could only be determined for five cities, personal exposure to total PM2.5 was also considered. Surrogate exposures were estimated as ambient PM2.5 at the nearest monitor or predicted outside subjects’ homes. We estimated calibration coefficients by regressing true on surrogate exposures in random effects models. Results When monthly-averaged personal PM2.5 of ambient origin was used as the true exposure, calibration coefficients equaled 0.31 (95% CI:0.14, 0.47) for nearest monitor and 0.54 (95% CI:0.42, 0.65) for outdoor home predictions. Between-city heterogeneity was not found for outdoor home PM2.5 for either true exposure. Heterogeneity was significant for nearest monitor PM2.5, for both true exposures, but not after adjusting for city-average motor vehicle number for total personal PM2.5. Conclusions Calibration coefficients were <1, consistent with previously reported chronic health risks using nearest monitor exposures being under-estimated when ambient concentrations are the exposure of interest. Calibration coefficients were closer to 1 for outdoor home predictions, likely reflecting less spatial error. Further research is needed to determine how our findings can be incorporated in future health studies. PMID:24410940
Epidemiological studies of particulate matter (PM) routinely use concentrations measured with stationary outdoor monitors as surrogates for personal exposure. Despite the frequently reported poor correlations between ambient concentrations and total personal exposure, the epidemi...
NASA Astrophysics Data System (ADS)
Kalkan, E.; Fletcher, J. B.; Ulusoy, H. S.; Baker, L. A.
2014-12-01
A 62-story residential tower in San Francisco—the tallest all-residential building in California—was recently instrumented by the USGS's National Strong Motion Project in collaboration with the Strong Motion Instrumentation Program of the California Geological Survey to monitor the motion of a tall building built with specifically engineered features (including buckling-restrained braces, outrigger columns and a tuned liquid damper) to reduce its sway from seismic and wind loads. This 641-ft tower has been outfitted with 72 uni-axial accelerometers, spanning through 26 different levels of the building. For damage detection and localization through structural health monitoring, we use local micro-earthquake and ambient monitoring (background noises) to define linear-elastic (undamaged) dynamic properties of the superstructure including its modal parameters (fundamental frequencies, mode shapes and modal damping values) and shear-wave propagation profile and wave attenuation inside the building, which need to be determined in advance of strong shaking. In order to estimate the baseline modal parameters, we applied a frequency domain decomposition method. Using this method, the first three bending modes in the reference east-west direction, the first two bending modes in the reference north-south direction, and the first two torsional modes were identified. The shear-wave propagation and wave attenuation inside the building were computed using deconvolution interferometry. The data used for analyses are from ambient vibrations having 20 minutes duration, and earthquake data from a local M4.5 event located just north east of Geyserville, California. We show that application of deconvolution interferometry to data recorded inside a building is a powerful technique for monitoring structural parameters, such as velocities of traveling waves, frequencies of normal modes, and intrinsic attenuation (i.e., damping). The simplicity and similarity of the deconvolved waveforms from ambient vibrations and a small magnitude event also suggest that a one-dimensional shear velocity model is sufficiently accurate to represent the wave propagation charactersistics inside the building.
Wu, Shaowei; Yang, Di; Pan, Lu; Shan, Jiao; Li, Hongyu; Wei, Hongying; Wang, Bin; Huang, Jing; Baccarelli, Andrea A; Shima, Masayuki; Deng, Furong; Guo, Xinbiao
2017-07-01
Associations of ambient temperature with cardiovascular morbidity and mortality have been well documented in numerous epidemiological studies, but the underlying pathways remain unclear. We investigated whether systemic inflammation, coagulation, systemic oxidative stress, antioxidant activity and endothelial function may be the mechanistic pathways associated with ambient temperature. Forty study participants underwent repeated blood collections for 12 times in Beijing, China in 2010-2011. Ambient temperature and air pollution data were measured in central monitors close to student residences. We created five indices as the sum of weighted biomarker percentiles to represent the overall levels of 15 cardiovascular biomarkers in five pathways (systemic inflammation: hs-CRP, TNF-α and fibrinogen; coagulation: fibrinogen, PAI-1, tPA, vWF and sP-selectin; systemic oxidative stress: Ox-LDL and sCD36: antioxidant activity: EC-SOD and GPX1; and endothelial function: ET-1, E-selectin, ICAM-1 and VCAM-1). We used generalized mixed-effects models to estimate temperature effects controlling for air pollution and other covariates. There were significant decreasing trends in the adjusted means of biomarker indices over the lowest to the highest quartiles of daily temperatures before blood collection. A 10°C decrease at 2-d average daily temperature were associated with increases of 2.5% [95% confidence interval (CI): 0.7, 4.2], 1.6% (95% CI: 0.1, 3.1), 2.7% (95% CI: 0.5, 4.8), 5.5% (95% CI: 3.8, 7.3) and 2.0% (95% CI: 0.3, 3.8) in the indices for systemic inflammation, coagulation, systemic oxidative stress, antioxidant activity and endothelial function, respectively. In contrast, the associations between ambient temperature and individual biomarkers had substantial variation in magnitude and strength. The altered cardiovascular biomarker profiles in healthy adults associated with ambient temperature changes may help explain the temperature-related cardiovascular morbidity and mortality. The biomarker index approach may serve as a novel tool to capture ambient temperature effects. Copyright © 2017. Published by Elsevier Inc.
A compact multi-channel fluorescence sensor with ambient light suppression
NASA Astrophysics Data System (ADS)
Egly, Dominik; Geörg, Daniel; Rädle, Matthias; Beuermann, Thomas
2012-03-01
A multi-channel fluorescence sensor has been developed for process monitoring and fluorescence diagnostics. It comprises a fiber-optic set-up with an immersion probe and an intensity-modulated high power ultraviolet light-emitting diode as a light source for fluorescence excitation. By applying an electronic lock-in procedure, fluorescence signals are selectively detectable at ambient light levels of 1000 000 times higher intensity. The sensor was designed to be compact, low cost and easily adaptable to a wide field of application. The set-up was used to simultaneously monitor three important metabolic fluorophores: NAD(P)H, flavins and porphyrins during the cultivation of a baker's yeast. Moreover, the accumulation and degradation kinetics of protoporphyrin IX induced by 5-aminolevulinic acid on the skin could be recorded by the sensor. The detection limit for protoporphyrin IX was determined to be 4 × 10-11 mol L-1. The linear signal amplification of the sensor and time courses of fluorescence signals monitored during yeast fermentations were validated using a commercial CCD spectrometer. The robust and flexible set-up of the fiber-optic measurement system promises easy implementation of this non-invasive analytical tool to fluorescence monitoring and diagnostics in R&D and production.
Kok, Gertjan; Persijn, Stefan; Sauerwald, Tilman
2017-01-01
This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions. PMID:28657595
Spinelle, Laurent; Gerboles, Michel; Kok, Gertjan; Persijn, Stefan; Sauerwald, Tilman
2017-06-28
This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions.
Ambient air monitoring plan for Ciudad Acuna and Piedra Negras, Coahuila, Mexico. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winberry, J.; Henning, L.; Crume, R.
1998-01-01
The Cities of Ciudad Acuna and Piedras Negras and the State of Coahuila in Mexico are interested in improving ambient air quality monitoring capabilities in the two cities through the establishment of a network of ambient air monitors. The purpose of the network is to characterize population exposure to potentially harmful air contaminants, possibly including sulfur dioxide (SO{sub 2}), nitrogen oxides (NO{sub x}), ozone (O{sub 3}), carbon monoxide (CO), total suspended particulate matter (TSP), particulate matter with aerodynamic diameter less than 100 micrometers PM-10, and lead. This report presents the results of an evaluation of existing air quality monitoring equipmentmore » and facilities in Ciudad Acuna and Piedras Negras. Additionally, the report presents recommendations for developing an air quality monitoring network for PM-10, SO{sub 2}, lead, and ozone in these cities, using a combination of both new and existing equipment. The human resources currently available and ultimately needed to operate and maintain the network are also discussed.« less
Crawford, Elizabeth A; Esen, Cemal; Volmer, Dietrich A
2016-09-06
Direct in-droplet (in stillo) microreaction monitoring using acoustically levitated micro droplets has been achieved by combining acoustic (ultrasonic) levitation for the first time with real time ambient tandem mass spectrometry (MS/MS). The acoustic levitation and inherent mixing of microliter volumes of reactants (3 μL droplets), yielding total reaction volumes of 6 μL, supported monitoring the acid-catalyzed degradation reaction of erythromycin A. This reaction was chosen to demonstrate the proof-of-principle of directly monitoring in stillo microreactions via hyphenated acoustic levitation and ambient ionization mass spectrometry. The microreactions took place completely in stillo over 30, 60, and 120 s within the containerless stable central pressure node of an acoustic levitator, thus readily promoting reaction miniaturization. For the evaluation of the miniaturized in stillo reactions, the degradation reactions were also carried out in vials (in vitro) with a total reaction volume of 400 μL. The reacted in vitro mixtures (6 μL total) were similarly introduced into the acoustic levitator prior to ambient ionization MS/MS analysis. The in stillo miniaturized reactions provided immediate real-time snap-shots of the degradation process for more accurate reaction monitoring and used a fraction of the reactants, while the larger scale in vitro reactions only yielded general reaction information.
Naito, Wataru; Uesaka, Motoki; Yamada, Chie; Kurosawa, Tadahiro; Yasutaka, Tetsuo; Ishii, Hideki
2016-01-01
The accident at Fukushima Daiichi Nuclear Power Plant on March 11, 2011, released radioactive material into the atmosphere and contaminated the land in Fukushima and several neighboring prefectures. Five years after the nuclear disaster, the radiation levels have greatly decreased due to physical decay, weathering, and decontamination operations in Fukushima. The populations of 12 communities were forced to evacuate after the accident; as of March 2016, the evacuation order has been lifted in only a limited area, and permanent habitation is still prohibited in most of the areas. In order for the government to lift the evacuation order and for individuals to return to their original residential areas, it is important to assess current and future realistic individual external doses. Here, we used personal dosimeters along with the Global Positioning System and Geographic Information System to understand realistic individual external doses and to relate individual external doses, ambient doses, and activity-patterns of individuals in the affected areas in Fukushima. The results showed that the additional individual external doses were well correlated to the additional ambient doses based on the airborne monitoring survey. The results of linear regression analysis suggested that the additional individual external doses were on average about one-fifth that of the additional ambient doses. The reduction factors, which are defined as the ratios of the additional individual external doses to the additional ambient doses, were calculated to be on average 0.14 and 0.32 for time spent at home and outdoors, respectively. Analysis of the contribution of various activity patterns to the total individual external dose demonstrated good agreement with the average fraction of time spent daily in each activity, but the contribution due to being outdoors varied widely. These results are a valuable contribution to understanding realistic individual external doses and the corresponding airborne monitoring-based ambient doses and time-activity patterns of individuals. Moreover, the results provide important information for predicting future cumulative doses after the return of residents to evacuation order areas in Fukushima.
Kurosawa, Tadahiro; Yasutaka, Tetsuo; Ishii, Hideki
2016-01-01
The accident at Fukushima Daiichi Nuclear Power Plant on March 11, 2011, released radioactive material into the atmosphere and contaminated the land in Fukushima and several neighboring prefectures. Five years after the nuclear disaster, the radiation levels have greatly decreased due to physical decay, weathering, and decontamination operations in Fukushima. The populations of 12 communities were forced to evacuate after the accident; as of March 2016, the evacuation order has been lifted in only a limited area, and permanent habitation is still prohibited in most of the areas. In order for the government to lift the evacuation order and for individuals to return to their original residential areas, it is important to assess current and future realistic individual external doses. Here, we used personal dosimeters along with the Global Positioning System and Geographic Information System to understand realistic individual external doses and to relate individual external doses, ambient doses, and activity-patterns of individuals in the affected areas in Fukushima. The results showed that the additional individual external doses were well correlated to the additional ambient doses based on the airborne monitoring survey. The results of linear regression analysis suggested that the additional individual external doses were on average about one-fifth that of the additional ambient doses. The reduction factors, which are defined as the ratios of the additional individual external doses to the additional ambient doses, were calculated to be on average 0.14 and 0.32 for time spent at home and outdoors, respectively. Analysis of the contribution of various activity patterns to the total individual external dose demonstrated good agreement with the average fraction of time spent daily in each activity, but the contribution due to being outdoors varied widely. These results are a valuable contribution to understanding realistic individual external doses and the corresponding airborne monitoring-based ambient doses and time-activity patterns of individuals. Moreover, the results provide important information for predicting future cumulative doses after the return of residents to evacuation order areas in Fukushima. PMID:27494021
INTERPOLATING VANCOUVER'S DAILY AMBIENT PM 10 FIELD
In this article we develop a spatial predictive distribution for the ambient space- time response field of daily ambient PM10 in Vancouver, Canada. Observed responses have a consistent temporal pattern from one monitoring site to the next. We exploit this feature of the field b...
Laboratory and field based evaluation of chromatography ...
The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat
Framework of sensor-based monitoring for pervasive patient care.
Triantafyllidis, Andreas K; Koutkias, Vassilis G; Chouvarda, Ioanna; Adami, Ilia; Kouroubali, Angelina; Maglaveras, Nicos
2016-09-01
Sensor-based health systems can often become difficult to use, extend and sustain. The authors propose a framework for designing sensor-based health monitoring systems aiming to provide extensible and usable monitoring services in the scope of pervasive patient care. The authors' approach relies on a distributed system for monitoring the patient health status anytime-anywhere and detecting potential health complications, for which healthcare professionals and patients are notified accordingly. Portable or wearable sensing devices measure the patient's physiological parameters, a smart mobile device collects and analyses the sensor data, a Medical Center system receives notifications on the detected health condition, and a Health Professional Platform is used by formal caregivers in order to review the patient condition and configure monitoring schemas. A Service-oriented architecture is utilised to provide extensible functional components and interoperable interactions among the diversified system components. The framework was applied within the REMOTE ambient-assisted living project in which a prototype system was developed, utilising Bluetooth to communicate with the sensors and Web services for data exchange. A scenario of using the REMOTE system and preliminary usability results show the applicability, usefulness and virtue of our approach.
Framework of sensor-based monitoring for pervasive patient care
Koutkias, Vassilis G.; Chouvarda, Ioanna; Adami, Ilia; Kouroubali, Angelina; Maglaveras, Nicos
2016-01-01
Sensor-based health systems can often become difficult to use, extend and sustain. The authors propose a framework for designing sensor-based health monitoring systems aiming to provide extensible and usable monitoring services in the scope of pervasive patient care. The authors’ approach relies on a distributed system for monitoring the patient health status anytime-anywhere and detecting potential health complications, for which healthcare professionals and patients are notified accordingly. Portable or wearable sensing devices measure the patient's physiological parameters, a smart mobile device collects and analyses the sensor data, a Medical Center system receives notifications on the detected health condition, and a Health Professional Platform is used by formal caregivers in order to review the patient condition and configure monitoring schemas. A Service-oriented architecture is utilised to provide extensible functional components and interoperable interactions among the diversified system components. The framework was applied within the REMOTE ambient-assisted living project in which a prototype system was developed, utilising Bluetooth to communicate with the sensors and Web services for data exchange. A scenario of using the REMOTE system and preliminary usability results show the applicability, usefulness and virtue of our approach. PMID:27733920
NASA Astrophysics Data System (ADS)
Liu, Lixian; Mandelis, Andreas; Melnikov, Alexander; Michaelian, Kirk; Huan, Huiting; Haisch, Christoph
2016-07-01
Air pollutants have adverse effects on the Earth's climate system. There is an urgent need for cost-effective devices capable of recognizing and detecting various ambient pollutants. An FTIR photoacoustic spectroscopy (FTIR-PAS) method based on a commercial FTIR spectrometer developed for air contamination monitoring will be presented. A resonant T-cell was determined to be the most appropriate resonator in view of the low-frequency requirement and space limitations in the sample compartment. Step-scan FTIR-PAS theory for regular cylinder resonator has been described as a reference for prediction of T-cell vibration principles. Both simulated amplitude and phase responses of the T-cell show good agreement with measurement data Carbon dioxide IR absorption spectra were used to demonstrate the capacity of the FTIR-PAS method to detect ambient pollutants. The theoretical detection limit for carbon dioxide was found to be 4 ppmv. A linear response to carbon dioxide concentration was found in the range from 2500 ppmv to 5000 ppmv. The results indicate that it is possible to use step-scan FTIR-PAS with a T-cell as a quantitative method for analysis of ambient contaminants.
Experimental investigation of observation error in anuran call surveys
McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.
2010-01-01
Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.
USDA-ARS?s Scientific Manuscript database
The navel orangeworm (NOW) is a major insect pest of California tree nuts. Its feeding damage lowers nut kernel quality resulting in considerable monetary loss to growers, producers, and shippers. Moreover, NOW feeding damage directly contributes to aflatoxin contamination. Hence, control of NOW has...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-02
... ambient ozone monitoring stations in the Atlanta Area from 2008-2011, as recorded in Air Quality System... redesignation request to change the legal designation of the Atlanta Area from nonattainment to attainment for... to change. Comment 2: The Commenter contends that Georgia's redesignation submittal is flawed because...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-23
... Protection, State Office Building, 79 Elm Street, Hartford, CT 06106- 1630; the Bureau of Air Quality Control... evaluation of the States' submittals? A. Emission Limits and Other Control Measures B. Ambient Air Quality Monitoring/Data System C. Program for Enforcement of Control Measures D. Interstate Transport E. Adequate...
PM2.5 Monitors in New England | Air Quality Planning Unit ...
2017-04-10
The New England states are currently operating a network of 58 ambient PM2.5 air quality monitors that meet EPA's Federal Reference Method (FRM) for PM2.5, which is necessary in order for the resultant data to be used for attainment/non-attainment purposes. These monitors collect particles in the ambient air smaller than 2.5 microns in size on a filter, which is weighed prior and post sampling to produce a 24-hour sample concentration.
Ambient air monitoring as part of the U.S. Environmental Protection Agency’s (U.S. EPA’s) Clean Air Status and Trends Network (CASTNet) currently uses filter packs to measure weekly integrated concentrations. The U.S. EPA is interested in supplementing CASTNet with semi-continuou...
A conceptual ground-water-quality monitoring network for San Fernando Valley, California
Setmire, J.G.
1985-01-01
A conceptual groundwater-quality monitoring network was developed for San Fernando Valley to provide the California State Water Resources Control Board with an integrated, basinwide control system to monitor the quality of groundwater. The geology, occurrence and movement of groundwater, land use, background water quality, and potential sources of pollution were described and then considered in designing the conceptual monitoring network. The network was designed to monitor major known and potential point and nonpoint sources of groundwater contamination over time. The network is composed of 291 sites where wells are needed to define the groundwater quality. The ideal network includes four specific-purpose networks to monitor (1) ambient water quality, (2) nonpoint sources of pollution, (3) point sources of pollution, and (4) line sources of pollution. (USGS)
Larson, Tuula; Östman, Conny; Colmsjö, Anders
2011-04-01
The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.
Wuytack, Tatiana; AbdElgawad, Hamada; Staelens, Jeroen; Asard, Han; Boeckx, Pascal; Verheyen, Kris; Samson, Roeland
2013-06-01
In this study we aimed to determine and elucidate the effect of ambient air pollution on the foliar antioxidant system and stable carbon and nitrogen isotopes of white willow (Salix alba L.). We grew white willow in uniform potting soil in the near vicinity of sixteen air quality monitoring stations in Belgium where nitrogen dioxide (NO2), ozone, sulfur dioxide and particulate matter concentrations were continuously measured. The trees were exposed to ambient air during six months (April-September 2011), and, thereafter, the degree of lipid peroxidation and foliar content of antioxidant molecules (ascorbate, glutathione, polyphenols, flavonoids), antioxidant enzymes (superoxide dismutase, ascorbate peroxidase, peroxidase) and foliar stable carbon (δ(13)C) and nitrogen (δ(15)N) isotopes were measured. We found that lipid peroxidation was caused by air pollution stress, arising from high ambient NO2 concentrations, as shown by an increased amount of malondialdehyde. The antioxidant system was activated by increasing the amount of polyphenols at monitoring stations with a high atmospheric NO2 and low O3 concentration, while no increase of key enzymes (e.g., ascorbate, glutathione) was observed. The δ(13)C also decreased with increasing NO2 concentrations and decreasing O3 concentrations, probably reflecting a decreased net photosynthesis and/or a concomitant decrease of (13)CO2 in the atmosphere. Shade also influenced foliar δ(13)C and the content of leaf ascorbate and glutathione. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Implicit Interaction: A Modality for Ambient Exercise Monitoring
NASA Astrophysics Data System (ADS)
Wan, J.; O'Grady, M. J.; O'Hare, G. M. P.
Ambient Exercise refers to the implicit exercise that people undertake in the course of their everyday duties - a simple example being climbing stairs. Increasing awareness of the potential health benefits of such activities may well contribute to an increase in a person’s well-being. Initially, it is necessary to monitor and quantify such exercise so that personalized fitness plans may be constructed. In this paper, the implicit interaction modality is harnessed to enable the capturing of ambient exercise activity thereby facilitating its subsequent quantification and interpretation. The novelty of the solution proposed lies in its ubiquity and transparency.
Bravo, Mercedes A; Fuentes, Montserrat; Zhang, Yang; Burr, Michael J; Bell, Michelle L
2012-07-01
Air quality modeling could potentially improve exposure estimates for use in epidemiological studies. We investigated this application of air quality modeling by estimating location-specific (point) and spatially-aggregated (county level) exposure concentrations of particulate matter with an aerodynamic diameter less than or equal to 2.5 μm (PM(2.5)) and ozone (O(3)) for the eastern U.S. in 2002 using the Community Multi-scale Air Quality (CMAQ) modeling system and a traditional approach using ambient monitors. The monitoring approach produced estimates for 370 and 454 counties for PM(2.5) and O(3), respectively. Modeled estimates included 1861 counties, covering 50% more population. The population uncovered by monitors differed from those near monitors (e.g., urbanicity, race, education, age, unemployment, income, modeled pollutant levels). CMAQ overestimated O(3) (annual normalized mean bias=4.30%), while modeled PM(2.5) had an annual normalized mean bias of -2.09%, although bias varied seasonally, from 32% in November to -27% in July. Epidemiology may benefit from air quality modeling, with improved spatial and temporal resolution and the ability to study populations far from monitors that may differ from those near monitors. However, model performance varied by measure of performance, season, and location. Thus, the appropriateness of using such modeled exposures in health studies depends on the pollutant and metric of concern, acceptable level of uncertainty, population of interest, study design, and other factors. Copyright © 2012 Elsevier Inc. All rights reserved.
Air pollution epidemiologic research has often utilized ambient air concentrations measured from centrally located monitors as a surrogate measure of exposure to these pollutants. Associations between these ambient concentrations and health outcomes such as lung function, hospita...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... Ambient Air Quality Standard AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY... the National Ambient Air Quality Standards (NAAQS) promulgated for ozone on July 18, 1997. EPA finds... measuring and monitoring ozone in ambient air, a general definition of ozone, federal Prevention of...
Development of a Portable Gamma-ray Survey System for the Measurement of Air Dose Rates
NASA Astrophysics Data System (ADS)
Goto, Jun; Shobugawa, Yugo; Kawano, Yoh; Amaya, Yoshihiro; Izumikawa, Takuji; Katsuragi, Yoshinori; Shiiya, Tomohiro; Suzuki, Tsubasa; Takahashi, Takeshi; Takahashi, Toshihiro; Yoshida, Hidenori; Naito, Makoto
BIo-Safety Hybrid Automatic MOnitor-Niigata (BISHAMON), a portable gamma-ray survey system, was developed to support victims of the Fukushima Daiichi nuclear disaster. BISHAMON is capable of constructing a map of the distribution of ambient dose equivalent rates using vehicle-mounted or on-foot survey methods. In this study, we give an overview of BISHAMON and its measurement results including a comparison with those of other systems such as KURAMA.
NASA Astrophysics Data System (ADS)
Oswald, Sandro M.; Pietsch, Helga; Baumgartner, Dietmar J.; Rieder, Harald E.
2016-04-01
A precise knowledge of the surface energy budget, which includes the solar and terrestrial radiation fluxes, is needed to accurately characterize the global energy balance which is largely determining Earth's climate. To this aim national and global monitoring networks for surface radiative fluxes have been established in recent decades. The most prominent among these networks is the so-called Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Programme (WCRP) (Ohmura et al., 1998). National monitoring networks such as the Austrian RADiation Monitoring Network (ARAD), which has been established in 2010 by a consortium of the Central Agency of Meteorology and Geodynamics (ZAMG), the University of Graz, the University of Innsbruck, and the University of Natural Resources and Applied Sciences, Vienna (BOKU), orient themselves on BSRN standards (McArthur, 2005). ARAD comprises to date five sites (Wien Hohe Warte, Graz/University, Innsbruck/University, Kanzelhöhe Observatory and Sonnblick (which is also a BSRN site)) and aims to provide long-term monitoring of radiation budget components at highest accuracy and to capture the spatial patterns of radiation climate in Austria (Olefs et al., 2015). Given the accuracy requirement for the local monitoring of radiative fluxes instrument offsets, triggered by meteorological factors and/or instrumentation, pose a major challenge in radiation monitoring. Within this study we investigate effects of ambient meteorology on the accuracy of radiation measurements performed with pyranometers contained in various heating/ventilation systems (HV-systems), all of which used in regular operation within the ARAD network. We focus particularly on instrument offsets observed following precipitation events. To quantify pyranometer responses to precipitation we performed a series of controlled laboratory experiments as well as targeted field campaigns in 2015 and 2016. Our results indicate that precipitation (as simulated by spray-tests or observed under ambient conditions) significantly affects the thermal environment of the instruments and thus their stability. Statistical analyses during nighttime conditions showed that precipitation triggers zero offsets of 4 W/m2 or more, depending on the HV-system and prevailing ambient conditions (i.e., air temperature, wind), indicating a clear exceedance of BSRN targets. References: McArthur L. J. B.: World Climate Research Programme-Baseline Surface Radiation Network (BSRN) - Operations Manual Version 2.1, Experimental Studies Division, Atmospheric Environment Service, Downsview, Ontario, Canada, 2005. Olefs M., Baumgartner D. J., Obleitner F., Bichler C., Foelsche U., Pietsch H., Rieder H. E., Weihs P., Geyer F., Haiden T., Schöner W.: The Austrian radiation monitoring network ARAD - best practice and added value, Atmospheric Measurement Techniques Discussions, 8: 10663-10710, 2015. Ohmura A., Dutton E. G., Forgan B., Frohlich C., Gilgen H., Hegner H., Heimo A., Stephens G. L., König-Langlo G., McArthur B., Müller G., Philipona R., Pinker R., Whitlock C. H., Dehne K., Wild M.: Baseline surface radiation network (bsrn/wcrp): new precision radiometry for climate research, Bulletin of the American Meteorological Society, 79(10): 2115-2136, 1998.
Central-site monitors do not account for factors such as outdoor-to-indoor transport and human activity patterns that influence personal exposures to ambient fine-particulate matter (PM2.5). We describe and compare different ambient PM2.5 exposure estimation...
The purpose of this SOP is to describe the general procedures to be followed for the operation and maintenance of the EcoChem real-time ambient air PAH monitor. This procedure was followed to ensure consistent data retrieval of PAH measurements during the Arizona NHEXAS project ...
Implications of observed and simulated ambient flow in monitoring wells.
Elci, B A; Molz, F J; Waldrop, W R
2001-01-01
A recent paper by Hutchins and Acree (2000) has called attention to ground water sampling bias due to ambient (natural gradient-induced) flows in monitoring wells. Data collected with borehole flowmeters have shown that such ambient flows are ubiquitous in both confined and unconfined aquifers. Developed herein is a detailed three-dimensional model of flow and transport in the vicinity of a fully penetrating monitoring well. The model was used to simulate a measured ambient flow distribution around a test well in a heterogeneous aquifer at the Savannah River Site (SRS) near Aiken, South Carolina. Simulated ambient flows agreed well with measurements. Natural flow was upward, so water entered the well mainly through high K layers in the lower portion of the aquifer and exited through similar layers in the upper portion. The maximum upward discharge in the well was about 0.28 L/min, which implied an induced exchange of 12 m3/month from the bottom half of the aquifer to the upper half. Tracer transport simulations then illustrated how a contaminant located initially in a lower portion of the aquifer was continuously transported into the upper portion and diluted throughout the entire well by in-flowing water. Even after full purging or micropurging, samples from such a well will yield misleading and ambiguous data concerning solute concentrations, location of a contaminant source, and plume geometry. For all of these reasons, use of long-screened monitoring wells should be phased out, unless an appropriate multilevel sampling device prevents vertical flow.
Passive ambient air sampling for nitrogen dioxide (NO2 and volatioe organic compounds (VOCs) was conducted at 25 schools and two compliance sites in Detroit and Dearborne, Michigan. Geographic Information System (GIS) data were calculated at each of 116 schools. The ...
49 CFR 571.304 - Standard No. 304; Compressed natural gas fuel container integrity.
Code of Federal Regulations, 2012 CFR
2012-10-01
... system over the entire liner, including the domes. Hoop wrapped means winding of filament in a....3Number and placement of thermocouples. To monitor flame temperature, place three thermocouples so that... average ambient wind velocity at the CNG fuel container during the period specified in S8.3.6 of this...
49 CFR 571.304 - Standard No. 304; Compressed natural gas fuel container integrity.
Code of Federal Regulations, 2014 CFR
2014-10-01
... system over the entire liner, including the domes. Hoop wrapped means winding of filament in a....3Number and placement of thermocouples. To monitor flame temperature, place three thermocouples so that... average ambient wind velocity at the CNG fuel container during the period specified in S8.3.6 of this...
49 CFR 571.304 - Standard No. 304; Compressed natural gas fuel container integrity.
Code of Federal Regulations, 2013 CFR
2013-10-01
... system over the entire liner, including the domes. Hoop wrapped means winding of filament in a....3Number and placement of thermocouples. To monitor flame temperature, place three thermocouples so that... average ambient wind velocity at the CNG fuel container during the period specified in S8.3.6 of this...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-14
... in EPA's Air Quality System (AQS) database. To account for missing data, the procedures found in... determination is based upon complete, certified, quality-assured ambient air quality monitoring data for the... proposing? II. What is the background for this proposed action? III. What is EPA's analysis of data for...
There are a number of Federal Reference Method (FRM) and Federal Equivalent Method (FEM) systems used to monitor the six criteria air pollutants (Lead [Pb], Carbon Monoxide [CO], Sulfur Dioxide [SO2], Nitrogen Dioxide [NO2], Ozone [O3], Particulate Matter [PM]) to determine if an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-11
... and emissions input data preparation, model performance evaluation, interpreting modeling results, and... standard based on ambient ozone monitoring data for the 2006- 2008 period. EPA has not yet acted on this... ppm) and years thereafter were at or below the standard. See EPA Air Quality System (AQS) data...
Lin, Chitsan; Liou, Naiwei; Sun, Endy
2008-06-01
An open-path Fourier transform infrared spectroscopy (OP-FTIR) system was set up for 3-day continuous line-averaged volatile organic compound (VOC) monitoring in a paint manufacturing plant. Seven VOCs (toluene, m-xylene, p-xylene, styrene, methanol, acetone, and 2-butanone) were identified in the ambient environment. Daytime-only batch operation mode was well explained by the time-series concentration plots. Major sources of methanol, m-xylene, acetone, and 2-butanone were identified in the southeast direction where paint solvent manufacturing processes are located. However, an attempt to uncover sources of styrene was not successful because the method detection limit (MDL) of the OP-FTIR system was not sensitive enough to produce conclusive data. In the second scenario, the OP-FTIR system was set up in an industrial complex to distinguish the origins of several VOCs. Eight major VOCs were identified in the ambient environment. The pollutant detected wind-rose percentage plots that clearly showed that ethylene, propylene, 2-butanone, and toluene mainly originated from the tank storage area, whereas the source of n-butane was mainly from the butadiene manufacturing processes of the refinery plant, and ammonia was identified as an accompanying reduction product in the gasoline desulfuration process. Advantages of OP-FTIR include its ability to simultaneously and continuously analyze many compounds, and its long path length monitoring has also shown advantages in obtaining more comprehensive data than the traditional multiple, single-point monitoring methods.
A multiparameter wearable physiologic monitoring system for space and terrestrial applications
NASA Technical Reports Server (NTRS)
Mundt, Carsten W.; Montgomery, Kevin N.; Udoh, Usen E.; Barker, Valerie N.; Thonier, Guillaume C.; Tellier, Arnaud M.; Ricks, Robert D.; Darling, Robert B.; Cagle, Yvonne D.; Cabrol, Nathalie A.;
2005-01-01
A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.
Changes in ambient dose equivalent rates around roads at Kawamata town after the Fukushima accident.
Kinase, Sakae; Sato, Satoshi; Sakamoto, Ryuichi; Yamamoto, Hideaki; Saito, Kimiaki
2015-11-01
Changes in ambient dose equivalent rates noted through vehicle-borne surveys have elucidated ecological half-lives of radioactive caesium in the environment. To confirm that the ecological half-lives are appropriate for predicting ambient dose equivalent rates within living areas, it is important to ascertain ambient dose equivalent rates on/around roads. In this study, radiation monitoring on/around roads at Kawamata town, located about 37 km northwest of the Fukushima Daiichi Nuclear Power Plant, was performed using monitoring vehicles and survey meters. It was found that the ambient dose equivalent rates around roads were higher than those on roads as of October 2012. And withal the ecological half-lives on roads were essentially consistent with those around roads. With dose predictions using ecological half-lives on roads, it is necessary to make corrections to ambient dose equivalent rates through the vehicle-borne surveys against those within living areas. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Region 7 States Air Quality Monitoring Plans - Iowa
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Region 7 States Air Quality Monitoring Plans - Missouri
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Region 7 States Air Quality Monitoring Plans - Nebraska
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Region 7 States Air Quality Monitoring Plans - Kansas
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Inferring Meal Eating Activities in Real World Settings from Ambient Sounds: A Feasibility Study
Thomaz, Edison; Zhang, Cheng; Essa, Irfan; Abowd, Gregory D.
2015-01-01
Dietary self-monitoring has been shown to be an effective method for weight-loss, but it remains an onerous task despite recent advances in food journaling systems. Semi-automated food journaling can reduce the effort of logging, but often requires that eating activities be detected automatically. In this work we describe results from a feasibility study conducted in-the-wild where eating activities were inferred from ambient sounds captured with a wrist-mounted device; twenty participants wore the device during one day for an average of 5 hours while performing normal everyday activities. Our system was able to identify meal eating with an F-score of 79.8% in a person-dependent evaluation, and with 86.6% accuracy in a person-independent evaluation. Our approach is intended to be practical, leveraging off-the-shelf devices with audio sensing capabilities in contrast to systems for automated dietary assessment based on specialized sensors. PMID:25859566
A high-resolution ambient seismic noise model for Europe
NASA Astrophysics Data System (ADS)
Kraft, Toni
2014-05-01
In the past several years, geological energy technologies receive growing attention and have been initiated in or close to urban areas. Some of these technologies involve injecting fluids into the subsurface (e.g., oil and gas development, waste disposal, and geothermal energy development) and have been found or suspected to cause small to moderate sized earthquakes. These earthquakes, which may have gone unnoticed in the past when they occurred in remote sparsely populated areas, are now posing a considerable risk for the public acceptance of these technologies in urban areas. The permanent termination of the EGS project in Basel, Switzerland after a number of induced ML~3 (minor) earthquakes in 2006 is one prominent example. It is therefore essential to the future development and success of these geological energy technologies to develop strategies for managing induced seismicity and keeping the size of induced earthquake at a level that is acceptable to all stakeholders. Most guidelines and recommendations on induced seismicity published since the 1970ies conclude that an indispensable component of such a strategy is the establishment of seismic monitoring in an early stage of a project. This is because an appropriate seismic monitoring is the only way to detect and locate induced microearthquakes with sufficient certainty to develop an understanding of the seismic and geomechanical response of the reservoir to the geotechnical operation. In addition, seismic monitoring lays the foundation for the establishment of advanced traffic light systems and is therefore an important confidence building measure towards the local population and authorities. Due to this development an increasing number of seismic monitoring networks are being installed in densely populated areas with strongly heterogeneous, and unfavorable ambient noise conditions. This poses a major challenge on the network design process, which aims to find the sensor geometry that optimizes the measurement precision (i.e. earthquake location), while considering this extremely complex boundary condition. To solve this problem I have developed a high-resolution ambient seismic noise model for Europe. The model is based on land-use data derived from satellite imagery by the EU-project CORINE in a resolution of 100x100m. The the CORINE data consists of several land-use classes, which, besides others, contain: industrial areas, mines, urban fabric, agricultural areas, permanent corps, forests and open spaces. Additionally, open GIS data for highways, and major and minor roads and railway lines were included from the OpenStreetMap project (www.openstreetmap.org). This data was divided into three classes that represent good, intermediate and bad ambient conditions of the corresponding land-use class based on expert judgment. To account for noise propagation away from its source a smoothing operator was applied to individual land-use noise-fields. Finally, the noise-fields were stacked to obtain an European map of ambient noise conditions. A calibration of this map with data of existing seismic stations Europe allowed me to estimate the expected noise level in actual ground motion units for the three ambient noise condition classes of the map. The result is a high-resolution ambient seismic noise map, that allows the network designer to make educated predictions on the expected noise level for arbitrary location in Europe. The ambient noise model was successfully tested in several network optimization projects in Switzerland and surrounding countries and will hopefully be a valuable contribution to improving the data quality of microseismic monitoring networks in Europe.
Quality of surface water in Missouri, water year 2012
Barr, Miya N.
2014-01-01
The U.S. Geological Survey, in cooperation with the Missouri Department of Natural Resources, designed and operates a series of monitoring stations on streams and springs throughout Missouri known as the Ambient Water-Quality Monitoring Network. During the 2012 water year (October 1, 2011, through September 30, 2012), data were collected at 81 stations—73 Ambient Water-Quality Monitoring Network stations, 6 alternate Ambient Water-Quality Monitoring Network stations, and 2 U.S. Geological Survey National Stream Quality Accounting Network stations. Dissolved oxygen, specific conductance, water temperature, suspended solids, suspended sediment, fecal coliform bacteria, Escherichia coli bacteria, dissolved nitrate plus nitrite as nitrogen, total phosphorus, dissolved and total recoverable lead and zinc, and select pesticide compound summaries are presented for 78 of these stations. The stations primarily have been classified into groups corresponding to the physiography of the State, primary land use, or unique station types. In addition, a summary of hydrologic conditions in the State including peak discharges, monthly mean discharges, and 7-day low flow is presented.
Quality of surface water in Missouri, water year 2013
Barr, Miya N.; Schneider, Rachel E.
2014-01-01
The U.S. Geological Survey, in cooperation with the Missouri Department of Natural Resources, designed and operates a series of monitoring stations on streams and springs throughout Missouri known as the Ambient Water-Quality Monitoring Network. During the 2013 water year (October 1, 2012, through September 30, 2013), data were collected at 79 stations—73 Ambient Water-Quality Monitoring Network stations, 4 alternate Ambient Water-Quality Monitoring Network stations, and 2 U.S. Geological Survey National Stream Quality Accounting Network stations. Dissolved oxygen, specific conductance, water temperature, suspended solids, suspended sediment, Escherichia coli bacteria, fecal coliform bacteria, dissolved nitrate plus nitrite as nitrogen, total phosphorus, dissolved and total recoverable lead and zinc, and select pesticide compound summaries are presented for 76 of these stations. The stations primarily have been classified into groups corresponding to the physiography of the State, primary land use, or unique station types. In addition, a summary of hydrologic conditions in the State including peak discharges, monthly mean discharges, and 7-day low flow is presented.
Monitoring activity patterns and trends of older adults.
Virone, G; Sixsmith, A
2008-01-01
This paper presents a pattern mining model developed for the continuous monitoring of high level activities and home-based behaviors for functional and cognitive status assessment with ambient assisted living systems such as in the EU-funded SOPRANO project. Motivating older people to engage in regular physical exercise is a key task of SOPRANO to improve health status and executive functions. A case study has been elaborated through software simulations to show how physical everyday life activity such as walking or sitting could be assessed and controlled for a better health lifestyle using the model.
Monitoring Sea Surface Processes Using the High Frequency Ambient Sound Field
2006-09-30
Pacific (ITCZ 10ºN, 95ºW), 3) Bering Sea coastal shelf, 4) Ionian Sea, 5) Carr Inlet, Puget Sound , Washington, and 6) Haro Strait, Washington/BC...Southern Resident Killer Whale ( Puget Sound ). In coastal and inland waterways, anthropogenic noise is often present. These signals are usually...Monitoring Sea Surface Processes Using the High Frequency Ambient Sound Field Jeffrey A. Nystuen Applied Physics Laboratory University of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, K.L.; Macak, J.J. III; Cioffi, J.
1999-07-01
The counties of Lake, Porter, and LaPorte in Northwest Indiana are classified as severe non-attainment for the ozone National Ambient Air Quality Standard (NAAQS). In response to the non-attainment problem, the Indiana Department of Environmental Management (IDEM) promulgated a number of regulations over the last several years. One of these rules requires steel mills with sinter plants to control and continuously monitor volatile organic compound (VOC) emissions from the facilities. One of the accepted compliance methods is to install and certify Continuous Emission Monitoring Systems (CEMS) to monitor VOC emissions and volumetric flow rate in order to generate a VOCmore » emission number in units of pounds per hour. Compliance with the regulation also requires that the sinter plants accurately monitor sinter production in order to determine compliance during the winter months, when the limits are based on pounds of VOC emissions per ton of sinter produced.« less
Anjaneyulu, Y; Jayakumar, I; Hima Bindu, V; Sagareswar, G; Mukunda Rao, P V; Rambabu, N; Ramani, K V
2005-08-01
A consensus has been emerging among public health experts in developing countries that air pollution, even at current ambient levels, aggravates respiratory and cardiovascular diseases and leads to premature mortality. Recent studies have also presented well-founded theories concerning the biological mechanisms involved and the groups of people that are probably more susceptible to health effects caused or exacerbated by inhalation of ambient particulate matter (PM.). On the basis of prognostic studies carried out in Center for Environment, JNT University, Hyderabad "it has been estimated that in Hyderabad some 1,700 to 3,000 people per year die prematurely as a result of inhaling PM". These figures reflect only the effects of acute exposure to air pollution. If the long-term effects of chronic exposure are taken into account, 10,000-15,000 people a year could die prematurely in Hyderabad. This estimate of the chronic effects is based on other studies, which are not completely comparable with the Hyderabad situation. While the study designs and analyses in these other studies may indeed be different or irrelevant to Hyderabad, the fact they were carried out in other countries is irrelevant. Taking into account these considerations, a model for total health risk assessment for the city of Hyderabad, and its state of Andhra Pradesh in India has been developed using a multi-objective air pollution monitoring network and online and real time air pollution monitoring stations. For the model studies a number of potential monitoring sites were screened for general and site-specific criteria in a geographic information system (GIS) environment that may, on a local basis, affect the representativeness of the data collected. Local features that may affect either the chemical or meteorological parameters are evaluated to assure a minimum of interference. Finally, for monitoring air pollution, an online and real-time monitoring system was designed using advanced electrochemical sensor systems (sulphur dioxide, oxides of nitrogen, carbon monoxide, hydrocarbons, ozone, mercaptans and hydrogen sulphide) and a particulate matter analyzer (total suspended particulate matter TSPM), PM2.5 and PM10). The sensor and data acquisition systems are programmed to monitor pollution levels at 1/2 hour durations during peak hours and at 1-hour intervals at other times. Presently, extensive statistical and numerical simulations are being carried out at our center to correlate the individuals living in the monitored areas with respiratory infections with air pollution.
Anjaneyulu, Y.; Jayakumar, I.; Bindu, V. Hima; Sagareswar, G.; Rao, P.V. Mukunda; Rambabu, N.; Ramani, K. V.
2005-01-01
A consensus has been emerging among public health experts in developing countries that air pollution, even at current ambient levels, aggravates respiratory and cardiovascular diseases and leads to premature mortality. Recent studies have also presented well-founded theories concerning the biological mechanisms involved and the groups of people that are probably more susceptible to health effects caused or exacerbated by inhalation of ambient particulate matter (PM.). On the basis of prognostic studies carried out in Center for Environment, JNT University, Hyderabad “it has been estimated that in Hyderabad some 1,700 to 3,000 people per year die prematurely as a result of inhaling PM”. These figures reflect only the effects of acute exposure to air pollution. If the long-term effects of chronic exposure are taken into account, 10,000–15,000 people a year could die prematurely in Hyderabad. This estimate of the chronic effects is based on other studies, which are not completely comparable with the Hyderabad situation. While the study designs and analyses in these other studies may indeed be different or irrelevant to Hyderabad, the fact they were carried out in other countries is irrelevant. Taking into account these considerations, a model for total health risk assessment for the city of Hyderabad, and its state of Andhra Pradesh in India has been developed using a multi-objective air pollution monitoring network and online and real time air pollution monitoring stations. For the model studies a number of potential monitoring sites were screened for general and site-specific criteria in a geographic information system (GIS) environment that may, on a local basis, affect the representativeness of the data collected. Local features that may affect either the chemical or meteorological parameters are evaluated to assure a minimum of interference. Finally, for monitoring air pollution, an online and real-time monitoring system was designed using advanced electrochemical sensor systems (sulphur dioxide, oxides of nitrogen, carbon monoxide, hydrocarbons, ozone, mercaptans and hydrogen sulphide) and a particulate matter analyzer (total suspended particulate matter TSPM), PM2.5 and PM10). The sensor and data acquisition systems are programmed to monitor pollution levels at ½ hour durations during peak hours and at 1-hour intervals at other times. Presently, extensive statistical and numerical simulations are being carried out at our center to correlate the individuals living in the monitored areas with respiratory infections with air pollution. PMID:16705838
Johnson Space Center's Regenerative Life Support Systems Test Bed
NASA Technical Reports Server (NTRS)
Barta, D. J.; Henninger, D. L.
1996-01-01
The Regenerative Life Support Systems (RLSS) Test Bed at NASA's Johnson Space Center is an atmospherically closed, controlled environment facility for human testing of regenerative life support systems using higher plants in conjunction with physicochemical life support systems. The facility supports NASA's Advanced Life Support (ALS) Program. The facility is comprised of two large scale plant growth chambers, each with approximately 11 m2 growing area. The root zone in each chamber is configurable for hydroponic or solid media plant culture systems. One of the two chambers, the Variable Pressure Growth Chamber (VPGC), is capable of operating at lower atmospheric pressures to evaluate a range of environments that may be used in a planetary surface habitat; the other chamber, the Ambient Pressure Growth Chamber (APGC) operates at ambient atmospheric pressure. The air lock of the VPGC is currently being outfitted for short duration (1 to 15 day) human habitation at ambient pressures. Testing with and without human subjects will focus on 1) integration of biological and physicochemical air and water revitalization systems; 2) effect of atmospheric pressure on system performance; 3) planetary resource utilization for ALS systems, in which solid substrates (simulated planetary soils or manufactured soils) are used in selected crop growth studies; 4) environmental microbiology and toxicology; 5) monitoring and control strategies; and 6) plant growth systems design. Included are descriptions of the overall design of the test facility, including discussions of the atmospheric conditioning, thermal control, lighting, and nutrient delivery systems.
Johnson Space Center's Regenerative Life Support Systems Test Bed
NASA Astrophysics Data System (ADS)
Barta, D. J.; Henninger, D. L.
1996-01-01
The Regenerative Life Support Systems (RLSS) Test Bed at NASA's Johnson Space Center is an atmospherically closed, controlled environment facility for human testing of regenerative life support systems using higher plants in conjunction with physicochemical life support systems. The facility supports NASA's Advanced Life Support (ALS) Program. The facility is comprised of two large scale plant growth chambers, each with approximately 11 m^2 growing area. The root zone in each chamber is configurable for hydroponic or solid media plant culture systems. One of the two chambers, the Variable Pressure Growth Chamber (VPGC), is capable of operating at lower atmospheric pressures to evaluate a range of environments that may be used in a planetary surface habitat; the other chamber, the Ambient Pressure Growth Chamber (APGC) operates at ambient atmospheric pressure. The air lock of the VPGC is currently being outfitted for short duration (1 to 15 day) human habitation at ambient pressures. Testing with and without human subjects will focus on 1) integration of biological and physicochemical air and water revitalization systems; 2) effect of atmospheric pressure on system performance; 3) planetary resource utilization for ALS systems, in which solid substrates (simulated planetary soils or manufactured soils) are used in selected crop growth studies; 4) environmental microbiology and toxicology; 5) monitoring and control strategies; and 6) plant growth systems design. Included are descriptions of the overall design of the test facility, including discussions of the atmospheric conditioning, thermal control, lighting, and nutrient delivery systems.
Johnson Space Center's regenerative life support systems test bed
NASA Technical Reports Server (NTRS)
Henninger, Donald L.; Tri, Terry O.; Barta, Daniel J.; Stahl, Randal S.
1991-01-01
The Regenerative Life Support System (RLSS) Test Bed at NASA's Johnson Space Center is an atmospherically closed, controlled environment facility for the evaluation of regenerative life support systems using higher plants in conjunction with physicochemical life support systems. When completed, the facility will be comprised of two large scale plant growth chambers, each with approximately 10 m(exp 2) growing area. One of the two chambers, the Variable Pressure Growth Chamber (VPGC), will be capable of operating at lower atmospheric pressures to evaluate a range of environments that may be used in Lunar or Martian habitats; the other chamber, the Ambient Pressure Growth Chamber (APGC) will operate at ambient atmospheric pressure. The root zone in each chamber will be configurable for hydroponic or solid state media systems. Research will focus on: (1) in situ resource utilization for CELSS systems, in which simulated lunar soils will be used in selected crop growth studies; (2) integration of biological and physicochemical air and water revitalization systems; (3) effect of atmospheric pressure on system performance; and (4) monitoring and control strategies.
[Hygienic evaluation of the total mutagenic activity of snow samples from Magnitogorsk].
Legostaeva, T B; Ingel', F I; Antipanova, N A; Iurchenko, V V; Iuretseva, N A; Kotliar, N N
2010-01-01
The paper gives the results of 4-year monitoring of the total mutagenic activity of snow samples from different Magnitogork areas in a test for induction of dominant lethal mutations (DLM) in the gametes of Drosophila melanogaster. An association was first found between the rate of DLM and the content of some chemical compounds in the ambient air and snow samples; moreover all the substances present in the samples, which had found genotoxic effects, showed a positive correlation with the rate of DLM. Furthermore, direct correlations were first established between the rate of DLM and the air pollution index and morbidity rates in 5-7-year-old children residing in the areas under study. The findings allow the test for induction of dominant lethal mutations (DLM) in the gametes of Drosophila melanogaster to be recommended due to its unique informative and prognostic value for monitoring ambient air pollution and for extensive use in the risk assessment system.
Design and realization of high voltage disconnector condition monitoring system
NASA Astrophysics Data System (ADS)
Shi, Jinrui; Xu, Tianyang; Yang, Shuixian; Li, Buoyang
2017-08-01
The operation status of the high voltage disconnector directly affects the safe and stable operation of the power system. This article uses the wireless frequency hopping communication technology of the communication module to achieve the temperature acquisition of the switch contacts and high voltage bus, to introduce the current value of the loop in ECS, and judge the operation status of the disconnector by considering the ambient temperature, calculating the temperature rise; And through the acquisition of the current of drive motor in the process of switch closing and opening, and fault diagnosis of the disconnector by analyzing the change rule of the drive motor current, the condition monitoring of the high voltage disconnector is realized.
Breast screen new South wales generally demonstrates good radiologic viewing conditions.
Soh, BaoLin Pauline; Lee, Warwick; Diffey, Jennifer L; McEntee, Mark F; Kench, Peter L; Reed, Warren M; Brennan, Patrick C
2013-08-01
This study measured reading workstation monitors and the viewing environment currently available within BreastScreen New South Wales (BSNSW) centres to determine levels of adherence to national and international guidelines. Thirteen workstations from four BSNSW service centres were assessed using the American Association of Physicists in Medicine Task Group 18 Quality Control test pattern. Reading workstation monitor performance and ambient light levels when interpreting screening mammographic images were assessed using spectroradiometer CS-2000 and chroma meter CL-200. Overall, radiologic monitors within BSNSW were operating at good acceptable levels. Some non-adherence to published guidelines included the percentage difference in maximum luminance between pairs of primary monitors at individual workstations (61.5 % or 30.8 % of workstations depending on specific guidelines), maximum luminance (23.1 % of workstations), luminance non-uniformity (11.5 % of workstations) and minimum luminance (3.8 % of workstations). A number of ambient light measurements did not comply with the only available evidence-based guideline relevant to the methodology used in this study. Larger ambient light variations across sites are shown when monitors were switched off, suggesting that differences in ambient lighting between sites can be masked when a standard mammogram is displayed for photometric measurements. Overall, BSNSW demonstrated good adherence to available guidelines, although some non-compliance has been shown. Recently updated United Kingdom and Australian guidelines should help reduce confusion generated by the plethora and sometimes dated nature of currently available recommendations.
Wireless Sensor Networks for Ambient Assisted Living
Aquino-Santos, Raúl; Martinez-Castro, Diego; Edwards-Block, Arthur; Murillo-Piedrahita, Andrés Felipe
2013-01-01
This paper introduces wireless sensor networks for Ambient Assisted Living as a proof of concept. Our workgroup has developed an arrhythmia detection algorithm that we evaluate in a closed space using a wireless sensor network to relay the information collected to where the information can be registered, monitored and analyzed to support medical decisions by healthcare providers. The prototype we developed is then evaluated using the TelosB platform. The proposed architecture considers very specific restrictions regarding the use of wireless sensor networks in clinical situations. The seamless integration of the system architecture enables both mobile node and network configuration, thus providing the versatile and robust characteristics necessary for real-time applications in medical situations. Likewise, this system architecture efficiently permits the different components of our proposed platform to interact efficiently within the parameters of this study. PMID:24351665
Anderson, J.; Perry, J.
1999-01-01
The Intergovernmental Task Force on Monitoring has suggested studies on ambient (in-stream) and compliance (wastewater) data to determine if monitoring can be reduced locally or nationally. The similarity in temporal trends between retrospective ambient and compliance water-quality data collected from Pool 2 of the Mississippi River, USA, was determined for 1985–1995. Constituents studied included the following trace elements: arsenic (As), cadmium (Cd), chromium (Cr), hexavalent chromium (Cr61), copper (Cu), lead (Pb), mercury (Hg), nickel (Ni), selenium (Se), zinc (Zn), and polychlorinated biphenyls (PCBs). Water-column, bed-sediment, and fish-tissue (fillets) data collected by five government agencies comprised the ambient data set; effluent data from five registered facilities comprised the compliance data set. The nonparametric MannKendall trend test indicated that 33% of temporal trends in all data were statistically significant (P , 0.05). Possible reasons for this were low sample sizes, and a high percentage of samples below the analytical detection limit. Trends in compliance data were more distinct; most trace elements decreased significantly, probably due to improvements in wastewater treatment. Seven trace elements (Cr, Cd, Cu, Pb, Hg, Ni, and Zn) had statistically significant decreases in wastewater and portions of either or both ambient water and bed sediment. No trends were found in fish tissue. Inconsistency in trends between ambient and compliance data were often found for individual constituents, making overall similarity between the data sets difficult to determine. Logistical differences in monitoring programs, such as varying field and laboratory methods among agencies, made it difficult to assess ambient temporal trends.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-12
..., quality-assured and certified ambient air quality monitoring data for the 2006-2008 ozone seasons that... data for the 2009 ozone season have been recorded in the EPA's Air Quality System (AQS) and show that... NAAQS through 2020 in the areas. EPA is approving the 2005 base year emissions inventories for the...
Remote helicopter-borne detector for searching of methane leaks.
Berezin, A G; Malyugin, S V; Nadezhdinskii, A I; Namestnikov, D Yu; Ponurovskii, Ya Ya; Rudov, S G; Stavrovskii, D B; Shapovalov, Yu P; Vyazov, I E; Zaslavskii, V Ya
2007-04-01
Measurements of the content of various molecular impurities in the ambient air using helicopter- and aircraft-borne systems represent an extremely urgent challenge. In this respect, of special interest are the devices that that provide leakage monitoring in gas lines in order to prevent emergencies. In the paper results of the tunable diode laser-based instrument development and testing are presented.
40 CFR 86.107-96 - Sampling and analytical systems; evaporative emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... profile throughout the test, and an average tolerance of 2.0 °F over the duration of the test (where the... about the desired long-term ambient temperature profile. Interior surface temperatures shall not be less... monitor the atmosphere within the enclosure (a heated FID (HFID)(235°±15 °F (113±8 °C)) is recommended for...
40 CFR 86.107-96 - Sampling and analytical systems; evaporative emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... profile throughout the test, and an average tolerance of 2.0 °F over the duration of the test (where the... about the desired long-term ambient temperature profile. Interior surface temperatures shall not be less... monitor the atmosphere within the enclosure (a heated FID (HFID)(235°±15 °F (113±8 °C)) is recommended for...
40 CFR 86.107-96 - Sampling and analytical systems; evaporative emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... profile throughout the test, and an average tolerance of 2.0 °F over the duration of the test (where the... about the desired long-term ambient temperature profile. Interior surface temperatures shall not be less... monitor the atmosphere within the enclosure (a heated FID (HFID)(235°±15 °F (113±8 °C)) is recommended for...
NASA Astrophysics Data System (ADS)
Sutton, Patrick T.; Ginn, Timothy R.
2014-12-01
A sustainable in-well vapor stripping system is designed as a cost-effective alternative for remediation of shallow chlorinated solvent groundwater plumes. A solar-powered air compressor is used to inject air bubbles into a monitoring well to strip volatile organic compounds from a liquid to vapor phase while simultaneously inducing groundwater circulation around the well screen. An analytical model of the remediation process is developed to estimate contaminant mass flow and removal rates. The model was calibrated based on a one-day pilot study conducted in an existing monitoring well at a former dry cleaning site. According to the model, induced groundwater circulation at the study site increased the contaminant mass flow rate into the well by approximately two orders of magnitude relative to ambient conditions. Modeled estimates for 5 h of pulsed air injection per day at the pilot study site indicated that the average effluent concentrations of dissolved tetrachloroethylene and trichloroethylene can be reduced by over 90% relative to the ambient concentrations. The results indicate that the system could be used cost-effectively as either a single- or multi-well point technology to substantially reduce the mass of dissolved chlorinated solvents in groundwater.
NASA Technical Reports Server (NTRS)
King, R. B.; Fordyce, J. S.; Antoine, A. C.; Leibecki, H. F.; Neustadter, H. E.; Sidik, S. M.; Burr, J. C.; Craig, G. T.; Cornett, C. L.
1974-01-01
Beginning in 1971 a cooperative program has been carried on by the City of Cleveland Division of Air Pollution Control and NASA Lewis Research Center to study the trace element and compound concentrations in the ambient suspended particulate matter in Cleveland Ohio as a function of source, monitoring location and meteorological conditions. The major objectives were to determine the ambient concentration levels at representative urban sites and to develop a technique using trace element and compound data in conjunction with meteorological conditions to identify specific pollution sources which could be developed into a practical system that could be readily utilized by an enforcement agency.
Classifying Sources Influencing Indoor Air Quality (IAQ) Using Artificial Neural Network (ANN)
Mad Saad, Shaharil; Melvin Andrew, Allan; Md Shakaff, Ali Yeon; Mohd Saad, Abdul Rahman; Muhamad Yusof @ Kamarudin, Azman; Zakaria, Ammar
2015-01-01
Monitoring indoor air quality (IAQ) is deemed important nowadays. A sophisticated IAQ monitoring system which could classify the source influencing the IAQ is definitely going to be very helpful to the users. Therefore, in this paper, an IAQ monitoring system has been proposed with a newly added feature which enables the system to identify the sources influencing the level of IAQ. In order to achieve this, the data collected has been trained with artificial neural network or ANN—a proven method for pattern recognition. Basically, the proposed system consists of sensor module cloud (SMC), base station and service-oriented client. The SMC contain collections of sensor modules that measure the air quality data and transmit the captured data to base station through wireless network. The IAQ monitoring system is also equipped with IAQ Index and thermal comfort index which could tell the users about the room’s conditions. The results showed that the system is able to measure the level of air quality and successfully classify the sources influencing IAQ in various environments like ambient air, chemical presence, fragrance presence, foods and beverages and human activity. PMID:26007724
Ambient air quality programmes for health impact assessment in the WHO European region.
Mücke, H G
2000-06-01
An important aim of air quality assessment is to provide information about population exposure and health impact assessment. Numerous epidemiological studies have already shown that exposure to excessive levels of ambient air pollutants are associated with either acute or chronic health effects. Until recently, the adequacy of monitoring population exposure in relation to quantitative assessment of health effects of air pollution was rarely considered in ambient air monitoring strategies. This made the formulation of health-related recommendations to risk management difficult and weakens preventive and other measures to reduce adverse health effects of air pollution. To improve local and national capacities for health impact assessment, the European Centre for Environment and Health of the World Health Organization has prepared methodology guidelines concerning selected aspects of air monitoring. The WHO Collaborating Centre for Air Quality Management and Air Pollution Control support efforts in line with international programmes on quality assurance and control for Europe.
NASA Astrophysics Data System (ADS)
Chao, H. Jasmine; Chan, Chang-Chuan; Rao, Carol Y.; Lee, Chung-Te; Chuang, Ying-Chih; Chiu, Yueh-Hsiu; Hsu, Hsiao-Hsien; Wu, Yi-Hua
2012-03-01
This study was conducted to evaluate the effects of transported Asian dust and other environmental parameters on the levels and compositions of ambient fungi in the atmosphere of northern Taiwan. We monitored Asian dust events in Taipei County, Taiwan from January 2003 to June 2004. We used duplicate Burkard portable air samplers to collect ambient fungi before, during, and after dust events. Six transported Asian dust events were monitored during the study period. Elevated concentrations of Aspergillus ( A. niger, specifically), Coelomycetes, Rhinocladiella, Sporothrix and Verticillium were noted ( p < 0.05) during Asian dust periods. Botryosporium and Trichothecium were only recovered during dust event days. Multiple regression analysis showed that fungal levels were positively associated with temperature, wind speed, rainfall, non-methane hydrocarbons and particulates with aerodynamic diameters ≤10 μm (PM10), and negatively correlated with relative humidity and ozone. Our results demonstrated that Asian dust events affected ambient fungal concentrations and compositions in northern Taiwan. Ambient fungi also had complex dynamics with air pollutants and meteorological factors. Future studies should explore the health impacts of ambient fungi during Asian dust events, adjusting for the synergistic/antagonistic effects of weather and air pollutants.
A method to characterise site, urban and regional ambient background radiation.
Passmore, C; Kirr, M
2011-03-01
Control dosemeters are routinely provided to customers to monitor the background radiation so that it can be subtracted from the gross response of the dosemeter to arrive at the occupational dose. Landauer, the largest dosimetry processor in the world with subsidiaries in Australia, Brazil, China, France, Japan, Mexico and the UK, has clients in approximately 130 countries. The Glenwood facility processes over 1.1 million controls per year. This network of clients around the world provides a unique ability to monitor the world's ambient background radiation. Control data can be mined to provide useful historical information regarding ambient background rates and provide a historical baseline for geographical areas. Historical baseline can be used to provide site or region-specific background subtraction values, document the variation in ambient background radiation around a client's site or provide a baseline for measuring the efficiency of clean-up efforts in urban areas after a dirty bomb detonation.
Alpha-environmental continuous air monitor inlet
Rodgers, John C.
2003-01-01
A wind deceleration and protective shroud that provides representative samples of ambient aerosols to an environmental continuous air monitor (ECAM) has a cylindrical enclosure mounted to an input on the continuous air monitor, the cylindrical enclosure having shrouded nozzles located radially about its periphery. Ambient air flows, often along with rainwater flows into the nozzles in a sampling flow generated by a pump in the continuous air monitor. The sampling flow of air creates a cyclonic flow in the enclosure that flows up through the cylindrical enclosure until the flow of air reaches the top of the cylindrical enclosure and then is directed downward to the continuous air monitor. A sloped platform located inside the cylindrical enclosure supports the nozzles and causes any moisture entering through the nozzle to drain out through the nozzles.
NASA Technical Reports Server (NTRS)
1976-01-01
The papers deal with the detection of hazardous environmental pollutants, the development of emission control plans, and the design of compliance monitoring systems. Topics include remote sensing techniques in environmental pollution monitoring, monitoring of atmospheric particulate matter, air pollution due to sulfur dioxide and other inorganic compounds, marine pollution, atmospheric aerosols, industrial pollution, and legal aspects of pollution monitoring. Other papers examine the toxic effects of heavy metals and halogenated hydrocarbons, pollution associated with waste-disposal processes, pesticide residues in soil and groundwater, evaluations of groundwater quality, and monitoring of nuclear wastes. The interaction of climate and pollution is also discussed along with global pollutant transport, environmental modeling, ambient environmental air quality, aircraft and ground-vehicle emissions, and pollution associated with energy extraction and utilization processes. Individual items are announced in this issue.
Tim’s expertise and interests lie in the area of air pollution exposure assessment, including ambient air monitoring, personal monitoring, source apportionment, and air quality and exposure modeling.
Leston, Alan R; Ollison, Will M
2017-11-01
Long-standing measurement techniques for determining ground-level ozone (O 3 ) and nitrogen dioxide (NO 2 ) are known to be biased by interfering compounds that result in overestimates of high O 3 and NO 2 ambient concentrations under conducive conditions. An increasing near-ground O 3 gradient (NGOG) with increasing height above ground level is also known to exist. Both the interference bias and NGOG were investigated by comparing data from a conventional Federal Equivalent Method (FEM) O 3 photometer and an identical monitor upgraded with an "interference-free" nitric oxide O 3 scrubber that alternatively sampled at 2 m and 6.2 m inlet heights above ground level (AGL). Intercomparison was also made between a conventional nitrogen oxide (NO x ) chemiluminescence Federal Reference Method (FRM) monitor and a new "direct-measure" NO 2 NO x 405 nm photometer at a near-road air quality measurement site. Results indicate that the O 3 monitor with the upgraded scrubber recorded lower regulatory-oriented concentrations than the deployed conventional metal oxide-scrubbed monitor and that O 3 concentrations 6.2 m AGL were higher than concentrations 2.0 m AGL, the nominal nose height of outdoor populations. Also, a new direct-measure NO 2 photometer recorded generally lower NO 2 regulatory-oriented concentrations than the conventional FRM chemiluminescence monitor, reporting lower daily maximum hourly average concentrations than the conventional monitor about 3 of every 5 days. Employing bias-prone instruments for measurement of ambient ozone or nitrogen dioxide from inlets at inappropriate heights above ground level may result in collection of positively biased data. This paper discusses tests of new regulatory instruments, recent developments in bias-free ozone and nitrogen dioxide measurement technology, and the presence/extent of a near-ground O 3 gradient (NGOG). Collection of unbiased monitor inlet height-appropriate data is crucial for determining accurate design values and meeting National Ambient Air Quality Standards.
40 CFR 58.61 - Monitoring other pollutants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Monitoring other pollutants. 58.61 Section 58.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Federal Monitoring § 58.61 Monitoring other pollutants. The...
40 CFR 58.13 - Monitoring network completion.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Monitoring network completion. 58.13 Section 58.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a...
40 CFR 58.13 - Monitoring network completion.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Monitoring network completion. 58.13 Section 58.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a...
40 CFR 58.13 - Monitoring network completion.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Monitoring network completion. 58.13 Section 58.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Crist
2008-12-31
As stated in the proposal: Ohio University, in collaboration with CONSOL Energy, Advanced Technology Systems, Inc (ATS) and Atmospheric and Environmental Research, Inc. (AER) as subcontractors, evaluated the impact of emissions from coal-fired power plants in the Ohio River Valley region as they relate to the transport and deposition of mercury and associated fine particulate matter. This evaluation involved two interrelated areas of effort: ambient air monitoring and regional-scale modeling analysis. The scope of work for the ambient air monitoring included the deployment of a surface air monitoring (SAM) station in southeastern Ohio. The SAM station contains sampling equipment tomore » collect and measure mercury (including speciated forms of mercury and wet and dry deposited mercury), particulate matter (PM) mass, PM composition, and gaseous criteria pollutants (CO, NOx, SO2, O3, etc.). Laboratory analyses of time-integrated samples were used to obtain chemical speciation of ambient PM composition and mercury in precipitation. Nearreal- time measurements were used to measure the ambient concentrations of PM mass and all gaseous species including Hg0 and RGM. Approximately 30 months of field data were collected at the SAM site to validate the proposed regional model simulations for episodic and seasonal model runs. The ambient air quality data provides mercury, and fine particulate matter data that can be used by Ohio Valley industries to assess performance on multi-pollutant control systems. The scope of work for the modeling analysis includes (1) development of updated inventories of mercury emissions from coal plants and other important sources in the modeled domain; (2) adapting an existing 3-D atmospheric chemical transport model to incorporate recent advancements in the understanding of mercury transformations in the atmosphere; (3) analyses of the flux of Hg0, RGM, and fine particulate matter in the different sectors of the study region to identify key transport mechanisms; (4) comparison of cross correlations between species from the model results to observations in order to evaluate characteristics of specific air masses associated with long-range transport from a specified source region; and (5) evaluation of the sensitivity of these correlations to emissions from regions along the transport path. This is accomplished by multiple model runs with emissions simulations switched on and off from the various source regions. To the greatest extent possible, model results were compared to field data collected at other air monitoring sites in the Ohio Valley region, operated independently of this project. These sites may include (1) the DOE National Energy Technologies Laboratory’s monitoring site at its suburban Pittsburgh, PA facility; (2) sites in Pittsburgh (Lawrenceville) PA and Holbrook, PA operated by ATS; (3) sites in Steubenville, OH and Pittsburgh, PA operated by the USEPA and/or its contractors; and (4) sites operated by State or local air regulatory agencies. Field verification of model results and predictions provides critical information for the development of cost effective air pollution control strategies by the coal-fired power plants in the Ohio River Valley region.« less
40 CFR 58.60 - Federal monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Federal monitoring. 58.60 Section 58.60... QUALITY SURVEILLANCE Federal Monitoring § 58.60 Federal monitoring. The Administrator may locate and operate an ambient air monitoring site if the State or local agency fails to locate, or schedule to be...
Observations of interference between portable particle counters and NOx monitors
NASA Astrophysics Data System (ADS)
Bereznicki, Sarah D.; Kamal, Ali
2013-08-01
Studies in environmental exposure science have developed a preference for smaller devices that can be easily co-located without need for gas standards, such as those instruments utilized in the Near-road Exposures and Effects from Urban Air Pollutants Study (NEXUS). One observation from NEXUS was the potential for instrument interference from alcohol-based particle counters on photometric-based nitrogen oxide (NOx) monitors. This article reports the findings from laboratory tests replicating enclosed-shelter monitoring configurations and operation cycles for a common photometric-based NOx monitor and a widely used alcohol-based particle counter. These tests monitored the NOx response while the particle counter sampling interval and ambient airflow rate were varied to (1) confirm that proximity between the instruments induced interferences, (2) identify any dependencies in NOx monitor recovery on ambient airflow, and (3) determine the time needed for the NOx monitor to recover to pre-interference levels under different atmospheric conditions. During particle counter operations, NOx concentrations responded instantaneously with a several-fold jump above the measurement baseline. When the particle counter was operated for more than 10 min, this interference period also showed a marked decline in the NOx baseline. The overall recovery time of the NOx monitor depended less on the time of particle counter operation, and more on the speed of ambient airflow. If photometric-based NOx monitors need to be operated alongside alcohol-based particle counters, mechanisms must be employed to exhaust alcohol-based vapors from enclosed monitoring environments. Given the strong evidence for interference, however, it is recommended these devices not be operated within close proximity to one another.
NASA Astrophysics Data System (ADS)
Gadkari, Neelima M.; Pervez, Shamsh
Multiple 24-h average outdoor, indoor and personal respirable particulate matter (RPM) measurements were made in different urban residential colonies to determine major routes of personal exposure. The study area was Bhilai-Durg, District Durg, Chhattisgarh, India. About 100 residentials from each of two selected colonies have been surveyed for consent to participate in the study and for preparation of time-activity diary. On the basis of their time-activity diary, residentials have been categorized into three types: type-A, purely residential; type-B, residents who go out, and type-C, residence who go into work, specially in industrial area. A total of 28 adult participants (14 males and 14 females; mean age 40±15, range 21-61 years) were selected and monitored longitudinally during the summer (15 March-15 June) of 2004. Participants' residential indoor RPM level and also local ambient outdoor RPM levels were measured,and these are done simultaneous with personal monitoring. Residential indoor and ambient outdoors RPM monitoring sessions were throughout the year to obtain infiltration factor more precisely. To compare RPM levels with Indian National Ambient Air Quality Standards (NAAQS) of PM 10, simultaneous measurements of PM 10 were also done with the course of ambient outdoor RPM monitoring. RPM levels in indoors were higher compared to ambient outdoors. The annual average ratio RPM/PM 10 was found to vary significantly among residential sites due to variation in surroundings. Source contribution estimates (SCE) of personal exposure to RPM in selected 12 residences (six from each colony) have been investigated using chemical mass balance model CMB8. Ambient outdoors, residential indoors, soils and road-traffic borne RPM were identified as main routes and principal sources of personal RPM. Results of model output have shown that residential indoors and soil-borne RPM are the major routes of personal exposure.
An airborne laser fluorosensor for the detection of oil on water
NASA Technical Reports Server (NTRS)
Kim, H. H.; Hickman, G. D.
1975-01-01
An airborne laser fluorosensor for the detection of oil derivatives on water has been tested. The system transmits 337 nm UV radiation at the rate of 100 pulses per second and monitors fluorescent emission at 540 nm. Daylight flight tests were made over the areas of controlled oil spills and additional reconnaissance flights were made over a 50 km stretch of the Delaware River to establish ambient oil baseline in the river. The results show that the device is capable of monitoring and mapping out extremely low level oil on water which cannot be identified by ordinary photographic method.
NASA Astrophysics Data System (ADS)
Moloney, J. E.; Hannay, D.; Mouy, X.; Mouy, P. A.; Urazghildiiev, I.; Dakin, T.
2016-02-01
Recently JASCO Applied Sciences (Canada) Ltd (JASCO), Ocean Networks Canada (ONC) and the Port of Metro Vancouver (PMV) have collaborated in the installation of a novel, real-time ocean observing (listening) system (PMV-ECHO system deployed in the Strait of Georgia, BC. This system was designed specifically to measure ambient noise, vessel source levels, and to detect, classify, localize and track marine mammals using their vocalization in order to estimate population density. The listening station deployment and monitoring activities are part of the Enhancing Cetacean Habitat and Observation (ECHO) Program. The program aims to better understand and manage the impact of shipping activities on at-risk whales throughout the southern coast of British Columbia. The PMV-ECHO system is composed of two unique spatial arrays of four hydrophones and one active projector each. Both arrays are used to measure and monitor the environment and calibrate the hydrophones over time. Further, a new shored-based data processing and visualization system (JMesh) is used automatically process the data and to enable operators to easily provide measurement information, navigate through large time series of detections, examine spectrograms, listen to detected sounds, validate detections, and compare detections for different species over time and space. The JMesh web platform has been designed to overcome the otherwise overwhelming volume of acoustic data collected by the PMV-ECHO sensor systems. This paper will describe how the PMV-ECHO system along with the automated real-time analysis and visualization software suite can be used study marine mammal distribution and behavior, variation of vessel noises and potential effects of anthropogenic activities on marine mammals. The goal of the PMV-ECHO program is to find ways to reduce shipping impact on at-risk species especially in the approaches to large ports. This program and its scientific and technical approaches should be of interest to many marine organizations, industries, researchers and enforcement agencies.
Review on energy harvesting for structural health monitoring in aeronautical applications
NASA Astrophysics Data System (ADS)
Le, Minh Quyen; Capsal, Jean-Fabien; Lallart, Mickaël; Hebrard, Yoann; Van Der Ham, Andre; Reffe, Nicolas; Geynet, Lionel; Cottinet, Pierre-Jean
2015-11-01
This paper reviews recent developments in energy harvesting technologies for structural health monitoring (SHM) in aeronautical applications. Aeronautical industries show a great deal of interest in obtaining technologies that can be used to monitor the health of machinery and structures. In particular, the need for self-sufficient monitoring of structures has been ever-increasing in recent years. Autonomous SHM systems typically include embedded sensors, and elements for data acquisition, wireless communication, and energy harvesting. Among all of these components, this paper focuses on energy harvesting technologies. Actually, low-power sensors and wireless communication components are used in newer SHM systems, and a number of researchers have recently investigated such techniques to extract energy from the local environment to power these stand-alone systems. The first part of the paper is dedicated to the different energy sources available in aeronautical applications, i.e., for airplanes and helicopters. The second part gives a presentation of the various devices developed for converting ambient energy into electric power. The last part is dedicated to a comparison of the different technologies and the future development of energy harvesting for aeronautical applications.
Feasibility of energy harvesting techniques for wearable medical devices.
Voss, Thaddaeus J; Subbian, Vignesh; Beyette, Fred R
2014-01-01
Wearable devices are arguably one of the most rapidly growing technologies in the computing and health care industry. These systems provide improved means of monitoring health status of humans in real-time. In order to cope with continuous sensing and transmission of biological and health status data, it is desirable to move towards energy autonomous systems that can charge batteries using passive, ambient energy. This not only ensures uninterrupted data capturing, but could also eliminate the need to frequently remove, replace, and recharge batteries. To this end, energy harvesting is a promising area that can lead to extremely power-efficient portable medical devices. This paper presents an experimental prototype to study the feasibility of harvesting two energy sources, solar and thermoelectric energy, in the context of wearable devices. Preliminary results show that such devices can be powered by transducing ambient energy that constantly surrounds us.
NASA Astrophysics Data System (ADS)
Chiang, Chih-Wei; Chiang, Hong-Wei; Chou, Huann-Ming; Sun, Shu-Huang; Lee, Jiann-Shen
2017-06-01
The wind-blown dust emissions frequently occur in the open storage yards of steel-making companies. Tracking the dust source and monitoring their dispersion are rather difficult. This type of open-air storage yards poses many environmental hazards. The 3-D scanning lidar system is effective in environmental monitoring (e.g., dust) with high temporal and spatial resolution, which is lacking in traditional ground-based measurement. The objective of this paper is to make an attempt for the flux estimation of dust concentration by using lidar system. Further, we investigate the dynamical process of dust and their relationship with local air quality monitoring data. The results show that the material storage erosion by wind ( 3.6 m/s) could cause dust to elevate up to 20m height above the material storage, and produces the flux of dust around 674 mg/s. The flux of dust is proportional to the dust mass concentration (PM10) measured by commercial ambient particular monitors.
40 CFR 58.15 - Annual air monitoring data certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Annual air monitoring data certification. 58.15 Section 58.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.15 Annual air monitoring data...
40 CFR 58.13 - Monitoring network completion.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Monitoring network completion. 58.13... (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a) The network of NCore multipollutant sites must be physically established no later than January 1, 2011...
40 CFR 58.13 - Monitoring network completion.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Monitoring network completion. 58.13... (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a) The network of NCore multipollutant sites must be physically established no later than January 1, 2011...
40 CFR 58.15 - Annual air monitoring data certification.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Annual air monitoring data certification. 58.15 Section 58.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.15 Annual air monitoring data...
NASA Technical Reports Server (NTRS)
Meneghelli, Barry; Parrish, Clyde; Barile, Ron; Lueck, Dale E.
1995-01-01
A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevins, N; Vanderhoek, M; Lang, S
2014-06-15
Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary andmore » secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.« less
NASA Astrophysics Data System (ADS)
Ni, Y. Q.; Fan, K. Q.; Zheng, G.; Chan, T. H. T.; Ko, J. M.
2003-08-01
An automatic modal identification program is developed for continuous extraction of modal parameters of three cable-supported bridges in Hong Kong which are instrumented with a long-term monitoring system. The program employs the Complex Modal Indication Function (CMIF) algorithm to identify modal properties from continuous ambient vibration measurements in an on-line manner. By using the LabVIEW graphical programming language, the software realizes the algorithm in Virtual Instrument (VI) style. The applicability and implementation issues of the developed software are demonstrated by using one-year measurement data acquired from 67 channels of accelerometers deployed on the cable-stayed Ting Kau Bridge. With the continuously identified results, normal variability of modal vectors caused by varying environmental and operational conditions is observed. Such observation is very helpful for selection of appropriate measured modal vectors for structural health monitoring applications.
A versatile fiber-optic coupled system for sensitive optical spectroscopy in strong ambient light
NASA Astrophysics Data System (ADS)
Sinha, Sudarson Sekhar; Verma, Pramod Kumar; Makhal, Abhinandan; Pal, Samir Kumar
2009-05-01
In this work we describe design and use of a fiber-optic based optical system for the spectroscopic studies on the samples under the presence of strong ambient light. The system is tested to monitor absorption, emission, and picosecond-resolved fluorescence transients simultaneously with a time interval of 500 ms for several hours on a biologically important sample (vitamin B2) under strong UV light. An efficient stray-light rejection ratio of the setup is achieved by the confocal geometry of the excitation and detection channels. It is demonstrated using this setup that even low optical signal from a liquid sample under strong UV-exposure for the picosecond-resolved fluorescence transient measurement can reliably be detected by ultrasensitive microchannel plate photomultiplier tube solid state detector. The kinetics of photodeterioration of vitamin B2 measured using our setup is consistent with that reported in the literature. Our present studies also justify the usage of tungsten light than the fluorescent light for the healthy preservation of food with vitamin B2.
Çelebi, Mehmet; Toksöz, Nafi; Büyüköztürk, Oral
2014-01-01
A state-of-the-art seismic monitoring system comprising 36 accelerometers and a data-logger with real-time capability was recently installed at Building 54 on the Massachusetts Institute of Technology's (MIT) Cambridge, MA, campus. The system is designed to record translational, torsional, and rocking motions, and to facilitate the computation of drift between select pairs of floors. The cast-in-place, reinforced concrete building is rectangular in plan but has vertical irregularities. Heavy equipment is installed asymmetrically on the roof. Spectral analyses and system identification performed on five sets of low-amplitude ambient data reveal distinct and repeatable fundamental translational frequencies in the structural NS and EW directions (0.75 Hz and 0.68 Hz, respectively), a torsional frequency of 1.49 Hz, a rocking frequency of 0.75 Hz, and very low damping. Such results from low-amplitude data serve as a baseline against which to compare the behavior and performance of the building during stronger shaking caused by future earthquakes in the region.
Radio-frequency energy harvesting for wearable sensors.
Borges, Luís M; Chávez-Santiago, Raul; Barroca, Norberto; Velez, Fernando José; Balasingham, Ilangko
2015-02-01
The use of wearable biomedical sensors for the continuous monitoring of physiological signals will facilitate the involvement of the patients in the prevention and management of chronic diseases. The fabrication of small biomedical sensors transmitting physiological data wirelessly is possible as a result of the tremendous advances in ultra-low power electronics and radio communications. However, the widespread adoption of these devices depends very much on their ability to operate for long periods of time without the need to frequently change, recharge or even use batteries. In this context, energy harvesting (EH) is the disruptive technology that can pave the road towards the massive utilisation of wireless wearable sensors for patient self-monitoring and daily healthcare. Radio-frequency (RF) transmissions from commercial telecommunication networks represent reliable ambient energy that can be harvested as they are ubiquitous in urban and suburban areas. The state-of-the-art in RF EH for wearable biomedical sensors specifically targeting the global system of mobile 900/1800 cellular and 700 MHz digital terrestrial television networks as ambient RF energy sources are showcased. Furthermore, guidelines for the choice of the number of stages for the RF energy harvester are presented, depending on the requirements from the embedded system to power supply, which is useful for other researchers that work in the same area. The present authors' recent advances towards the development of an efficient RF energy harvester and storing system are presented and thoroughly discussed too.
On-Road Chemical Transformation as an Important Mechanism of NO2 Formation.
Yang, Bo; Zhang, K Max; Xu, W David; Zhang, Shaojun; Batterman, Stuart; Baldauf, Richard W; Deshmukh, Parikshit; Snow, Richard; Wu, Ye; Zhang, Qiang; Li, Zhenhua; Wu, Xian
2018-04-17
Nitrogen dioxide (NO 2 ) not only is linked to adverse effects on the respiratory system but also contributes to the formation of ground-level ozone (O 3 ) and fine particulate matter (PM 2.5 ). Our curbside monitoring data analysis in Detroit, MI, and Atlanta, GA, strongly suggests that a large fraction of NO 2 is produced during the "tailpipe-to-road" stage. To substantiate this finding, we designed and carried out a field campaign to measure the same exhaust plumes at the tailpipe-level by a portable emissions measurement system (PEMS) and at the on-road level by an electric vehicle-based mobile platform. Furthermore, we employed a turbulent reacting flow model, CTAG, to simulate the on-road chemistry behind a single vehicle. We found that a three-reaction (NO-NO 2 -O 3 ) system can largely capture the rapid NO to NO 2 conversion (with time scale ≈ seconds) observed in the field studies. To distinguish the contributions from different mechanisms to near-road NO 2 , we clearly defined a set of NO 2 /NO x ratios at different plume evolution stages, namely tailpipe, on-road, curbside, near-road, and ambient background. Our findings from curbside monitoring, on-road experiments, and simulations imply the on-road oxidation of NO by ambient O 3 is a significant, but so far ignored, contributor to curbside and near-road NO 2 .
Ice Detector and Deicing Fluid Effectiveness Monitoring System
NASA Technical Reports Server (NTRS)
Seegmiller, H. Lee B. (Inventor)
1996-01-01
An ice detector and deicing fluid effectiveness monitoring system for an aircraft is disclosed. The ice detection portion is particularly suited for use in flight to notify the flight crew of an accumulation of ice on an aircraft lifting and control surfaces, or helicopter rotors, whereas the deicing fluid effectiveness monitoring portion is particularly suited for use on the ground to notify the flight crew of the possible loss of the effectiveness of the deicing fluid. The ice detection portion comprises a temperature sensor and a parallel arrangement of electrodes whose coefficient of coupling is indicative of the formation of the ice, as well as the thickness of the formed ice. The fluid effectiveness monitoring portion comprises a temperature sensor and an ionic-conduction cell array that measures the conductivity of the deicing fluid which is indicative of its concentration and, thus, its freezing point. By measuring the temperature and having knowledge of the freezing point of the deicing fluid, the fluid effectiveness monitoring portion predicts when the deicing fluid may lose its effectiveness because its freezing point may correspond to the temperature of the ambient.
Monitoring earthen dams and levees with ambient seismic noise
NASA Astrophysics Data System (ADS)
Planès, T.; Mooney, M.; Rittgers, J. B.; Kanning, W.; Draganov, D.
2017-12-01
Internal erosion is a major cause of failure of earthen dams and levees and is difficult to detect at an early stage by traditional visual inspection techniques. The passive and non-invasive ambient-noise correlation technique could help detect and locate internal changes taking place within these structures. First, we apply this passive seismic method to monitor a canal embankment model submitted to piping erosion, in laboratory-controlled conditions. We then present the monitoring of a sea levee in the Netherlands. A 150m-long section of the dike shows sandboils in the drainage ditch located downstream of the levee. These sandboils are the sign of concentrated seepage and potential initiation of internal erosion in the structure. Using the ambient-noise correlation technique, we retrieve surface waves propagating along the crest of the dike. Temporal variations of the seismic wave velocity are then computed during the tide cycle. These velocity variations are correlated with local in-situ pore water pressure measurements and are possibly influenced by the presence of concentrated seepage paths.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-16
...EPA is making two determinations regarding the Philadelphia- Wilmington, PA-NJ-DE fine particulate (PM2.5) nonattainment area (the Philadelphia Area). First, EPA is making a determination that the Philadelphia Area has attained the 1997 annual PM2.5 national ambient air quality standard (NAAQS) by its attainment date of April 5, 2010. This determination is based upon quality assured and certified ambient air monitoring data that show the area monitored attainment of the 1997 annual PM2.5 NAAQS for the 2007-2009 monitoring period. Second, EPA is making a clean data determination, finding that the Philadelphia Area has attained the 1997 PM2.5 NAAQS, based on quality assured and certified ambient air monitoring data for the 2007-2009 and 2008-2010 monitoring periods. In accordance with EPA's applicable PM2.5 implementation rule, this determination suspends the requirement for the Philadelphia Area to submit an attainment demonstration, reasonably available control measures/reasonably available control technology (RACM/RACT), a reasonable further progress (RFP) plan, and contingency measures related to attainment of the 1997 annual PM2.5 NAAQS for so long as the area continues to attain the 1997 annual PM2.5 NAAQS. These actions are being taken under the Clean Air Act (CAA).
Baltrėnaitė, Edita; Baltrėnas, Pranas; Lietuvninkas, Arvydas; Serevičienė, Vaida; Zuokaitė, Eglė
2014-01-01
The composition of the ambient air is constantly changing; therefore, the monitoring of ambient air quality to detect the changes caused by aerogenic pollutants makes the essential part of general environmental monitoring. To achieve more effective improvement of the ambient air quality, the Directive 2008/50/EC on 'Ambient Air Quality and Cleaner Air for Europe' was adopted by the European Parliament and the European Council. It informed the public and enterprises about a negative effect of pollution on humans, animals and plants, as well as about the need for monitoring aerogenic pollutants not only at the continuous monitoring stations but also by using indicator methods, i.e. by analysing natural deposit media. The problem of determining the relationship between the accumulation level of pollutants by a deposit medium and the level of air pollution and its risks is constantly growing in importance. The paper presents a comprehensive analysis of the response of the main four deposit media, i.e. snow cover, soil, pine bark and epigeic mosses, to the long-term pollution by aerogenic pollutants which can be observed in the area of oil refinery influence. Based on the quantitative expressions of the amounts of the accumulated pollutants in the deposit media, the territory of the oil refinery investigated in this paper has been referred to the areas of mild or moderate pollution.
NASA Technical Reports Server (NTRS)
Ives, R. E.
1982-01-01
A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.
Automatic electrochemical ambient air monitor for chloride and chlorine
Mueller, Theodore R.
1976-07-13
An electrochemical monitoring system has been provided for determining chloride and chlorine in air at levels of from about 10-1000 parts per billion. The chloride is determined by oxidation to chlorine followed by reduction to chloride in a closed system. Chlorine is determined by direct reduction at a platinum electrode in 6 M H.sub.2 SO.sub.4 electrolyte. A fully automated system is utilized to (1) acquire and store a value corresponding to electrolyte-containing impurities, (2) subtract this value from that obtained in the presence of air, (3) generate coulometrically a standard sample of chlorine mixed with air sample, and determine it as chlorine and/or chloride, and (4) calculate, display, and store for permanent record the ratio of the signal obtained from the air sample and that obtained with the standard.
Adapting radio technology to LED feedback systems
NASA Astrophysics Data System (ADS)
Salsbury, Marc; Ashdown, Ian
2007-09-01
Superheterodyne techniques were originally developed for radio transmission and reception nearly a century ago. In this paper we explore the adaptation of this technology to the problem of simultaneously monitoring the intensities of multiple LED channels with a single photosensor. The use of superheterodyne techniques obviates the need for multiple photosensors filters and tristimulus color filters to monitor the relative intensities of red, green, and blue LEDs. In addition, they alleviate the problems of electrical and optical noise, as well as the influence of ambient illumination on the photosensors. They can also be used to advantage with phosphor-coated white light LEDs in solid state lighting systems. Taking a broader view, the use of such techniques demonstrates the value of looking outside the realm of conventional LED power and control technologies when designing solid state lighting systems.
COMPARISON OF MEASUREMENTS OF AMBIENT PARTICLE NITRATE WITH SEMI-CONTINUOUS INSTRUMENTS
Comparisons between two different semi-continuous monitors of ambient level particulate nitrate are interpreted for both field and laboratory studies. One instrument involves thermal desorption of particulate nitrate to form a combination of NO and NO2 gases which are detected ...
COMPARISON OF MEASUREMENT OF AMBIENT PARTICLE NITRATE WITH SEMI-CONTINUOPUS INSTRUMENTS
Comparisons between two different semi-continuos monitors of ambient level particulate nitrate are interpreted for both field and laboratory studies. One instrument involves flash vaporization of impacted particulate nitrate to form a combination of NO and NO2 gases which are de...
MEASURING AIRBORNE PAHS FROM THE NEW YORK WORLD TRADE CENTER DISASTER
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous in ambient air, are suspected human carcinogens, and have been linked to genotoxic and mutagenic effects. Although there are no specific monitoring programs for PAHs in ambient air in the United States, there is a national...
Automated soil gas monitoring chamber
Edwards, Nelson T.; Riggs, Jeffery S.
2003-07-29
A chamber for trapping soil gases as they evolve from the soil without disturbance to the soil and to the natural microclimate within the chamber has been invented. The chamber opens between measurements and therefore does not alter the metabolic processes that influence soil gas efflux rates. A multiple chamber system provides for repetitive multi-point sampling, undisturbed metabolic soil processes between sampling, and an essentially airtight sampling chamber operating at ambient pressure.
Scale Factor and Noise Performance Tests of the Bendix Corporation Rate Gyro Assembly (RGA).
1980-08-01
tiltmeters , seismometers, and an ambient temperature monitor. 3.2 Test Support Equipment Bendix supplied all necessary test support equipment and...001A 2-Axis Tiltmeter Electrotechnical Lab EV22C Portable Seismic Mon- itor (PRM) Sensors USAF Sieler Laboratory PSM Electronics Rockland 816...acquisition system recorded the tiltmeter , seismometer, and temperature data on magnetic tape. The seismic, tilt, and temperature information was filtered
Comparison of scientific CMOS camera and webcam for monitoring cardiac pulse after exercise
NASA Astrophysics Data System (ADS)
Sun, Yu; Papin, Charlotte; Azorin-Peris, Vicente; Kalawsky, Roy; Greenwald, Stephen; Hu, Sijung
2011-09-01
In light of its capacity for remote physiological assessment over a wide range of anatomical locations, imaging photoplethysmography has become an attractive research area in biomedical and clinical community. Amongst recent iPPG studies, two separate research directions have been revealed, i.e., scientific camera based imaging PPG (iPPG) and webcam based imaging PPG (wPPG). Little is known about the difference between these two techniques. To address this issue, a dual-channel imaging PPG system (iPPG and wPPG) using ambient light as the illumination source has been introduced in this study. The performance of the two imaging PPG techniques was evaluated through the measurement of cardiac pulse acquired from the face of 10 male subjects before and after 10 min of cycling exercise. A time-frequency representation method was used to visualize the time-dependent behaviour of the heart rate. In comparison to the gold standard contact PPG, both imaging PPG techniques exhibit comparable functional characteristics in the context of cardiac pulse assessment. Moreover, the synchronized ambient light intensity recordings in the present study can provide additional information for appraising the performance of the imaging PPG systems. This feasibility study thereby leads to a new route for non-contact monitoring of vital signs, with clear applications in triage and homecare.
Sutton, Patrick T; Ginn, Timothy R
2014-12-15
A sustainable in-well vapor stripping system is designed as a cost-effective alternative for remediation of shallow chlorinated solvent groundwater plumes. A solar-powered air compressor is used to inject air bubbles into a monitoring well to strip volatile organic compounds from a liquid to vapor phase while simultaneously inducing groundwater circulation around the well screen. An analytical model of the remediation process is developed to estimate contaminant mass flow and removal rates. The model was calibrated based on a one-day pilot study conducted in an existing monitoring well at a former dry cleaning site. According to the model, induced groundwater circulation at the study site increased the contaminant mass flow rate into the well by approximately two orders of magnitude relative to ambient conditions. Modeled estimates for 5h of pulsed air injection per day at the pilot study site indicated that the average effluent concentrations of dissolved tetrachloroethylene and trichloroethylene can be reduced by over 90% relative to the ambient concentrations. The results indicate that the system could be used cost-effectively as either a single- or multi-well point technology to substantially reduce the mass of dissolved chlorinated solvents in groundwater. Copyright © 2014 Elsevier B.V. All rights reserved.
Analysis of 1995 speciated volatile organic compound data in the south central U.S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sather, M.E.; Kemp, M.G.; Yarbrough, J.W.
1997-12-31
An analysis of 1995 speciated volatile organic compound (VOC) data from three areas in the south central US has been performed for Baton Rouge, Louisiana, Houston, Texas, and El Paso, Texas. All three areas are required by the Clean Air Act Amendments of 1990 to collect ambient monitoring data for over 50 VOC species, including ten Clean Air Act Title III toxic compounds, as per the Photochemical Assessment Monitoring Stations (PAMS) requirements. The PAMS program was initiated to provide more detailed VOC data for scientists, modelers, and managers working toward eliminating violations of the ozone National Ambient Air Quality Standardsmore » (NAAQS). This paper presents useful information from a preliminary analysis of the 1995 speciated VOC and related data from Baton Rouge, Houston, and El Paso. All data analyzed were extracted from the US Environmental Protection Agency (EPA) Aerometric Information Retrieval System (AIRS) data base after collection and validation by the states of Louisiana and Texas. Key observations from the analyses include: (1) the presence of propane peaks coincident with ozone peaks during all three ozone episode days at the El Paso site; (2) the dominance of mobile source VOC emissions in the El Paso emission inventory, in contrast to the Baton Rouge and Houston VOC emission inventories, after noting strong correlations between carbon monoxide and major exhaust VOC species of gasoline; and (3) the 1995 ozone episodes at the Houston site were influenced by both morning build-up of ambient VOC concentrations and afternoon puffs of VOC emissions, while the 1995 ozone episodes at the Baton Rouge site were influenced by high early and mid-morning VOC ambient concentrations.« less
Baseline ambient gaseous ammonia concentrations in the Four Corners area and eastern Oklahoma, USA.
Sather, Mark E; Mathew, Johnson; Nguyen, Nghia; Lay, John; Golod, George; Vet, Robert; Cotie, Joseph; Hertel, Terry; Aaboe, Erik; Callison, Ryan; Adam, Jacque; Keese, Danielle; Freise, Jeremy; Hathcoat, April; Sakizzie, Brenda; King, Michael; Lee, Chris; Oliva, Sylvia; San Miguel, George; Crow, Leon; Geasland, Frank
2008-11-01
Ambient ammonia monitoring using Ogawa passive samplers was conducted in the Four Corners area and eastern Oklahoma, USA during 2007. The resulting data will be useful in the multipollutant management of ozone, nitrogen oxides, and visibility (atmospheric regional haze) in the Four Corners area, an area with growing oil/gas production and increasing coal-based power plant construction. The passive monitoring data also add new ambient ammonia concentration information for the U.S. and will be useful to scientists involved in present and future visibility modeling exercises. Three week integrated passive ammonia samples were taken at five sites in the Four Corners area and two sites in eastern Oklahoma from December, 2006 through December, 2007 (January, 2008 for two sites). Results show significantly higher regional background ammonia concentrations in eastern Oklahoma (1.8 parts per billion (ppb) arithmetic mean) compared to the Four Corners area (0.2 ppb arithmetic mean). Annual mean ammonia concentrations for all Four Corners area sites for the 2007 study ranged from 0.2 ppb to 1.5 ppb. Peak ambient ammonia concentrations occurred in the spring and summer in both areas. The passive samplers deployed at the Stilwell, Oklahoma site compared favorably with other passive samplers and a continuous ammonia monitoring instrument.
NASA Astrophysics Data System (ADS)
Maruccio, Claudio; Quaranta, Giuseppe; De Lorenzis, Laura; Monti, Giorgio
2016-08-01
Wireless monitoring could greatly impact the fields of structural health assessment and infrastructure asset management. A common problem to be tackled in wireless networks is the electric power supply, which is typically provided by batteries replaced periodically. A promising remedy for this issue would be to harvest ambient energy. Within this framework, the present paper proposes to harvest ambient-induced vibrations of bridge structures using a new class of piezoelectric textiles. The considered case study is an existing cable-stayed bridge located in Italy along a high-speed road that connects Rome and Naples, for which a recent monitoring campaign has allowed to record the dynamic responses of deck and cables. Vibration measurements have been first elaborated to provide a comprehensive dynamic assessment of this infrastructure. In order to enhance the electric energy that can be converted from ambient vibrations, the considered energy harvester exploits a power generator built using arrays of electrospun piezoelectric nanofibers. A finite element analysis is performed to demonstrate that such power generator is able to provide higher energy levels from recorded dynamic loading time histories than a standard piezoelectric energy harvester. Its feasibility for bridge health monitoring applications is finally discussed.
A continuous sampler with background suppression for monitoring alpha-emitting aerosol particles.
McFarland, A R; Rodgers, J C; Ortiz, C A; Moore, M E
1992-05-01
A continuous air monitor has been developed that includes provisions for improving the detection of alpha-emitting aerosol particles in the presence of radon/thoron progeny that are unattached to ambient aerosol particles. Wind tunnel tests show that 80% of 10-microns aerodynamic equivalent diameter particles penetrate the flow system from the ambient air to the collection filter when the flow rate is 57 L min-1 (2 cfm) and the wind speed is 1 m s-1. Uniformity of aerosol collection on the filter, as characterized by the coefficient of variation of the areal density deposits, is less than 15% for 10-microns aerodynamic-equivalent-diameter aerosol particles. Tests with unattached radon daughters in a flow-through chamber showed that approximately 99% of the 218Po was removed by an inlet screen that is designed to collect radon daughters that are in the size range of molecular clusters. The inlet screen offers the opportunity to improve the signal-to-noise ratio of energy spectra in the regions of interest (subranges of the energy spectrum) of transuranic elements and thereby enhance the performance of background compensation algorithms.
NASA Astrophysics Data System (ADS)
Zhang, T.
2015-12-01
There is a long term trend of haze in East China. As a main component of haze, fine particle (PM2.5) in various micro-environments (MEs) is a cause for concern regarding the environment and public health. To estimate individual PM2.5 exposures in distinct, non-residential MEs and to determine exposure characteristics during haze and clean days, we conducted personal PM2.5 monitoring with portable PM2.5 personal environment monitors (MicroPEM) in 19 indoor/outdoor MEs in Nanjing, and compared personal exposure data with ambient PM2.5 levels. Personal PM2.5 exposure patterns displayed notable spatial variance, peaking in snack streets and restaurants and dipping in subways and labs. Under both haze and non-haze conditions, different characteristics of MEs and the background PM2.5 level jointly determine the spatial variance of individual exposure. Indoor MEs with better ventilation systems led to lower personal PM2.5 exposure levels. During haze days, impact from high ambient PM2.5 overwhelms influence from other factors and dominates personal exposure trends.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mauk, F.J.; Davis, R.A.
1982-01-01
To investigate the seismic risks associated with geopressured fluid production from the Pleasant Bayou No. 2 design well a seismic monitoring program was conducted in the vicinity of the Brazoria County design wells since 1979. The monitoring program was designed first to establish the nature of the local ambient seismicity prior to production, and second to provide continued surveillance of the area during the well tests to determine if production altered ambient seismic conditions significantly. The operation, data analyses, results and conclusions of the Brazoria seismic network during the operational period from 1 January through 31 December 1982 are described.
Tominaga, M Y; Silva, C R; Melo, J P; Niwa, N A; Plascak, D; Souza, C A M; Sato, M I Z
2016-11-15
The persistent organic pollutants (POPs), such as organochlorine pesticides and PCBs, are ordinarily monitored in the aquatic environment or in soil in the environmental quality monitoring programs in São Paulo, Brazil. One of the core matrices proposed in the POPs Global Monitoring Plan (GMP) from the Stockholm Convention list is the ambient air, which is not a usual matrix for POPs monitoring in the country. In this study POP levels were evaluated in the air samples from an urban site in São Paulo City over five years, starting in 2010 as a capacity building project for Latin America and the Caribbean region for POP monitoring in ambient air using passive samplers. Furthermore, after the end of the Project in 2012, the monitoring continued in the same sampling site as means to improving the analytical capacity building and contribute to the GMP data. The POPs monitored were 17 congeners of 2,3,7,8 chloro-substituted PCDDs and PCDFs, dioxin-like PCBs, indicator PCBs, organochlorine pesticides and toxaphene. The results show a slight decrease in PCDD/F, dl-PCBs and indicator PCBs levels along the five years. The organochlorine pesticide endosulfan was present at its highest concentration at the beginning of the monitoring period, but it was below detection level in the last year of the monitoring. Some other organochlorine pesticides were detected close to or below quantitation limits. The compounds identified were dieldrin, chlordane, α-HCH, γ-HCH, heptachlor, heptachlor epoxide, hexachlorobenzene and DDTs. Toxaphene congeners were not detected. These results have confirmed the efficacy of passive sampling for POP monitoring and the capacity building for POP analysis and monitoring was established. However more needs to be done, including expansion of sampling sites, new POPs and studies on sampling rates to be considered in calculating the concentration of POPs in ambient air using a passive sampler. Copyright © 2016 Elsevier B.V. All rights reserved.
Development of a continuous monitoring system for PM10 and components of PM2.5.
Lippmann, M; Xiong, J Q; Li, W
2000-01-01
While particulate matter with aerodynamic diameters below 10 and 2.5 microns (PM10 and PM2.5) correlate with excess mortality and morbidity, there is evidence for still closer epidemiological associations with sulfate ion, and experimental exposure-response studies suggest that the hydrogen ion and ultrafine (PM0.15) concentrations may be important risk factors. Also, there are measurement artifacts in current methods used to measure ambient PM10 and PM2.5, including negative artifacts because of losses of sampled semivolatile components (ammonium nitrate and some organics) and positive artifacts due to particle-bound water. To study such issues, we are developing a semi-continuous monitoring system for PM10, PM2.5, semivolatiles (organic compounds and NH4NO3), particle-bound water, and other PM2.5 constituents that may be causal factors. PM10 is aerodynamically sorted into three size-fractions: (1) coarse (PM10-PM2.5); (2) accumulation mode (PM2.5-PM0.15); and (3) ultrafine (PM0.15). The mass concentration of each fraction is measured in terms of the linear relation between accumulated mass and pressure drop on polycarbonate pore filters. The PM0.15 mass, being highly correlated with the ultrafine number concentration, provides a good index of the total number concentration in ambient air. For the accumulation mode (PM2.5-PM0.15), which contains nearly all of the semivolatiles and particle-bound water by mass, aliquots of the aerosol stream flow into system components that continuously monitor sulfur (by flame photometry), ammonium and nitrate (by chemiluminescence following catalytic transformations to NO), organics (by thermal-optical analysis) and particle-bound water (by electrolytic hygrometer after vacuum evaporation of sampled particles). The concentration of H+ can be calculated (by ion balance using the monitoring data on NO3-, NH4+, and SO4=).
A Flexible Spatio-Temporal Model for Air Pollution with Spatial and Spatio-Temporal Covariates.
Lindström, Johan; Szpiro, Adam A; Sampson, Paul D; Oron, Assaf P; Richards, Mark; Larson, Tim V; Sheppard, Lianne
2014-09-01
The development of models that provide accurate spatio-temporal predictions of ambient air pollution at small spatial scales is of great importance for the assessment of potential health effects of air pollution. Here we present a spatio-temporal framework that predicts ambient air pollution by combining data from several different monitoring networks and deterministic air pollution model(s) with geographic information system (GIS) covariates. The model presented in this paper has been implemented in an R package, SpatioTemporal, available on CRAN. The model is used by the EPA funded Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air) to produce estimates of ambient air pollution; MESA Air uses the estimates to investigate the relationship between chronic exposure to air pollution and cardiovascular disease. In this paper we use the model to predict long-term average concentrations of NO x in the Los Angeles area during a ten year period. Predictions are based on measurements from the EPA Air Quality System, MESA Air specific monitoring, and output from a source dispersion model for traffic related air pollution (Caline3QHCR). Accuracy in predicting long-term average concentrations is evaluated using an elaborate cross-validation setup that accounts for a sparse spatio-temporal sampling pattern in the data, and adjusts for temporal effects. The predictive ability of the model is good with cross-validated R 2 of approximately 0.7 at subject sites. Replacing four geographic covariate indicators of traffic density with the Caline3QHCR dispersion model output resulted in very similar prediction accuracy from a more parsimonious and more interpretable model. Adding traffic-related geographic covariates to the model that included Caline3QHCR did not further improve the prediction accuracy.
Applications of energy harvesting for ultralow power technology
NASA Astrophysics Data System (ADS)
Pop-Vadean, A.; Pop, P. P.; Barz, C.; Chiver, O.
2015-06-01
Ultra-low-power (ULP) technology is enabling a wide range of new applications that harvest ambient energy in very small amounts and need little or no maintenance - self-sustaining devices that are capable of perpetual or nearly perpetual operation. These new systems, which are now appearing in industrial and consumer electronics, also promise great changes in medicine and health. Until recently, the idea of micro-scale energy harvesting, and collecting miniscule amounts of ambient energy to power electronic systems, was still limited to research proposals and laboratory experiments.Today an increasing number of systems are appearing that take advantage of light, vibrations and other forms of previously wasted environmental energy for applications where providing line power or maintaining batteries is inconvenient. In the industrial world, where sensors gather information from remote equipment and hazardous processes; in consumer electronics, where mobility and convenience are served; and in medical systems, with unique requirements for prosthetics and non-invasive monitoring, energy harvesting is rapidly expanding into new applications.This paper serves as a survey for applications of energy harvesting for ultra low power technology based on various technical papers available in the public domain.
40 CFR 57.403 - Written consent.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the Clean Air Act, for the smelter operated by (name of company) at (location), the undersigned...) between the company's smelter and any other smelter(s) for any violation of the National Ambient Air... of, and obtain data from ambient air quality monitors operated by the company under the requirements...
40 CFR 57.403 - Written consent.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the Clean Air Act, for the smelter operated by (name of company) at (location), the undersigned...) between the company's smelter and any other smelter(s) for any violation of the National Ambient Air... of, and obtain data from ambient air quality monitors operated by the company under the requirements...
40 CFR 57.403 - Written consent.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the Clean Air Act, for the smelter operated by (name of company) at (location), the undersigned...) between the company's smelter and any other smelter(s) for any violation of the National Ambient Air... of, and obtain data from ambient air quality monitors operated by the company under the requirements...
40 CFR 57.403 - Written consent.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the Clean Air Act, for the smelter operated by (name of company) at (location), the undersigned...) between the company's smelter and any other smelter(s) for any violation of the National Ambient Air... of, and obtain data from ambient air quality monitors operated by the company under the requirements...
Population-based epidemiologic studies of air pollution have traditionally relied upon imperfect surrogates of personal exposures, such as area-wide ambient air pollution levels based on readily available outdoor concentrations from central monitoring sites. This practice may in...
USEPA ambient air monitoring methods for volatile organic compounds (VOCs) using specially-prepared canisters and solid adsorbents are directly adaptable to monitoring for vapors in the indoor environment. The draft Method TO-15 Supplement, an extension of the USEPA Method TO-15,...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Crist
2005-10-02
Ohio University, in collaboration with CONSOL Energy, Advanced Technology Systems, Inc (ATS) and Atmospheric and Environmental Research, Inc. (AER) as subcontractors, is evaluating the impact of emissions from coal-fired power plants in the Ohio River Valley region as they relate to the transport and deposition of mercury, arsenic, and associated fine particulate matter. This evaluation will involve two interrelated areas of effort: ambient air monitoring and regional-scale modeling analysis. The scope of work for the ambient air monitoring will include the deployment of a surface air monitoring (SAM) station in southeastern Ohio. The SAM station will contain sampling equipment tomore » collect and measure mercury (including speciated forms of mercury and wet and dry deposited mercury), arsenic, particulate matter (PM) mass, PM composition, and gaseous criteria pollutants (CO, NOx, SO{sub 2}, O{sub 3}, etc.). Laboratory analysis of time-integrated samples will be used to obtain chemical speciation of ambient PM composition and mercury in precipitation. Near-real-time measurements will be used to measure the ambient concentrations of PM mass and all gaseous species including Hg{sup 0} and RGM. Approximately of 18 months of field data will be collected at the SAM site to validate the proposed regional model simulations for episodic and seasonal model runs. The ambient air quality data will also provide mercury, arsenic, and fine particulate matter data that can be used by Ohio Valley industries to assess performance on multi-pollutant control systems. The scope of work for the modeling analysis will include (1) development of updated inventories of mercury and arsenic emissions from coal plants and other important sources in the modeled domain; (2) adapting an existing 3-D atmospheric chemical transport model to incorporate recent advancements in the understanding of mercury transformations in the atmosphere; (3) analyses of the flux of Hg0, RGM, arsenic, and fine particulate matter in the different sectors of the study region to identify key transport mechanisms; (4) comparison of cross correlations between species from the model results to observations in order to evaluate characteristics of specific air masses associated with long-range transport from a specified source region; and (5) evaluation of the sensitivity of these correlations to emissions from regions along the transport path. This will be accomplished by multiple model runs with emissions simulations switched on and off from the various source regions. To the greatest extent possible, model results will also be compared to field data collected at other air monitoring sites in the Ohio Valley region, operated independently of this project. These sites may include (1) the DOE National Energy Technologies Laboratory's monitoring site at its suburban Pittsburgh, PA facility; (2) sites in Pittsburgh (Lawrenceville) PA and Holbrook, PA operated by ATS; (3) sites in Steubenville, OH and Pittsburgh, PA operated by U.S. EPA and/or its contractors; and (4) sites operated by State or local air regulatory agencies. Field verification of model results and predictions will provide critical information for the development of cost effective air pollution control strategies by the coal-fired power plants in the Ohio River Valley region.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Crist
2006-04-02
As stated in the proposal: Ohio University, in collaboration with CONSOL Energy, Advanced Technology Systems, Inc (ATS) and Atmospheric and Environmental Research, Inc. (AER) as subcontractors, is evaluating the impact of emissions from coal-fired power plants in the Ohio River Valley region as they relate to the transport and deposition of mercury, arsenic, and associated fine particulate matter. This evaluation will involve two interrelated areas of effort: ambient air monitoring and regional-scale modeling analysis. The scope of work for the ambient air monitoring will include the deployment of a surface air monitoring (SAM) station in southeastern Ohio. The SAM stationmore » will contain sampling equipment to collect and measure mercury (including speciated forms of mercury and wet and dry deposited mercury), arsenic, particulate matter (PM) mass, PM composition, and gaseous criteria pollutants (CO, NO{sub x}, SO{sub 2}, O{sub 3}, etc.). Laboratory analysis of time-integrated samples will be used to obtain chemical speciation of ambient PM composition and mercury in precipitation. Near-real-time measurements will be used to measure the ambient concentrations of PM mass and all gaseous species including Hg0 and RGM. Approximately 18 months of field data will be collected at the SAM site to validate the proposed regional model simulations for episodic and seasonal model runs. The ambient air quality data will also provide mercury, arsenic, and fine particulate matter data that can be used by Ohio Valley industries to assess performance on multi-pollutant control systems. The scope of work for the modeling analysis will include (1) development of updated inventories of mercury and arsenic emissions from coal plants and other important sources in the modeled domain; (2) adapting an existing 3-D atmospheric chemical transport model to incorporate recent advancements in the understanding of mercury transformations in the atmosphere; (3) analyses of the flux of Hg{sup 0}, RGM, arsenic, and fine particulate matter in the different sectors of the study region to identify key transport mechanisms; (4) comparison of cross correlations between species from the model results to observations in order to evaluate characteristics of specific air masses associated with long-range transport from a specified source region; and (5) evaluation of the sensitivity of these correlations to emissions from regions along the transport path. This will be accomplished by multiple model runs with emissions simulations switched on and off from the various source regions. To the greatest extent possible, model results will also be compared to field data collected at other air monitoring sites in the Ohio Valley region, operated independently of this project. These sites may include (1) the DOE National Energy Technologies Laboratory's monitoring site at its suburban Pittsburgh, PA facility; (2) sites in Pittsburgh (Lawrenceville) PA and Holbrook, PA operated by ATS; (3) sites in Steubenville, OH and Pittsburgh, PA operated by the USEPA and/or its contractors; and (4) sites operated by State or local air regulatory agencies. Field verification of model results and predictions will provide critical information for the development of cost effective air pollution control strategies by the coal-fired power plants in the Ohio River Valley region.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Crist
2005-04-02
Ohio University, in collaboration with CONSOL Energy, Advanced Technology Systems, Inc (ATS) and Atmospheric and Environmental Research, Inc. (AER) as subcontractors, is evaluating the impact of emissions from coal-fired power plants in the Ohio River Valley region as they relate to the transport and deposition of mercury, arsenic, and associated fine particulate matter. This evaluation will involve two interrelated areas of effort: ambient air monitoring and regional-scale modeling analysis. The scope of work for the ambient air monitoring will include the deployment of a surface air monitoring (SAM) station in southeastern Ohio. The SAM station will contain sampling equipment tomore » collect and measure mercury (including speciated forms of mercury and wet and dry deposited mercury), arsenic, particulate matter (PM) mass, PM composition, and gaseous criteria pollutants (CO, NO{sub x}, SO{sub 2}, O{sub 3}, etc.). Laboratory analysis of time-integrated samples will be used to obtain chemical speciation of ambient PM composition and mercury in precipitation. Near-real-time measurements will be used to measure the ambient concentrations of PM mass and all gaseous species including Hg{sup 0} and RGM. Approximately of 18 months of field data will be collected at the SAM site to validate the proposed regional model simulations for episodic and seasonal model runs. The ambient air quality data will also provide mercury, arsenic, and fine particulate matter data that can be used by Ohio Valley industries to assess performance on multi-pollutant control systems. The scope of work for the modeling analysis will include (1) development of updated inventories of mercury and arsenic emissions from coal plants and other important sources in the modeled domain; (2) adapting an existing 3-D atmospheric chemical transport model to incorporate recent advancements in the understanding of mercury transformations in the atmosphere; (3) analyses of the flux of Hg{sup 0}, RGM, arsenic, and fine particulate matter in the different sectors of the study region to identify key transport mechanisms; (4) comparison of cross correlations between species from the model results to observations in order to evaluate characteristics of specific air masses associated with long-range transport from a specified source region; and (5) evaluation of the sensitivity of these correlations to emissions from regions along the transport path. This will be accomplished by multiple model runs with emissions simulations switched on and off from the various source regions. To the greatest extent possible, model results will also be compared to field data collected at other air monitoring sites in the Ohio Valley region, operated independently of this project. These sites may include (1) the DOE National Energy Technologies Laboratory's monitoring site at its suburban Pittsburgh, PA facility; (2) sites in Pittsburgh (Lawrenceville) PA and Holbrook, PA operated by ATS; (3) sites in Steubenville, OH and Pittsburgh, PA operated by U.S. EPA and/or its contractors; and (4) sites operated by State or local air regulatory agencies. Field verification of model results and predictions will provide critical information for the development of cost effective air pollution control strategies by the coal-fired power plants in the Ohio River Valley region.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Crist
2004-10-02
Ohio University, in collaboration with CONSOL Energy, Advanced Technology Systems, Inc (ATS) and Atmospheric and Environmental Research, Inc. (AER) as subcontractors, is evaluating the impact of emissions from coal-fired power plants in the Ohio River Valley region as they relate to the transport and deposition of mercury, arsenic, and associated fine particulate matter. This evaluation will involve two interrelated areas of effort: ambient air monitoring and regional-scale modeling analysis. The scope of work for the ambient air monitoring will include the deployment of a surface air monitoring (SAM) station in southeastern Ohio. The SAM station will contain sampling equipment tomore » collect and measure mercury (including speciated forms of mercury and wet and dry deposited mercury), arsenic, particulate matter (PM) mass, PM composition, and gaseous criteria pollutants (CO, NOx, SO{sub 2}, O{sub 3}, etc.). Laboratory analysis of time-integrated samples will be used to obtain chemical speciation of ambient PM composition and mercury in precipitation. Near-real-time measurements will be used to measure the ambient concentrations of PM mass and all gaseous species including Hg{sup 0} and RGM. Approximately of 18 months of field data will be collected at the SAM site to validate the proposed regional model simulations for episodic and seasonal model runs. The ambient air quality data will also provide mercury, arsenic, and fine particulate matter data that can be used by Ohio Valley industries to assess performance on multi-pollutant control systems. The scope of work for the modeling analysis will include (1) development of updated inventories of mercury and arsenic emissions from coal plants and other important sources in the modeled domain; (2) adapting an existing 3-D atmospheric chemical transport model to incorporate recent advancements in the understanding of mercury transformations in the atmosphere; (3) analyses of the flux of Hg{sup 0}, RGM, arsenic, and fine particulate matter in the different sectors of the study region to identify key transport mechanisms; (4) comparison of cross correlations between species from the model results to observations in order to evaluate characteristics of specific air masses associated with long-range transport from a specified source region; and (5) evaluation of the sensitivity of these correlations to emissions from regions along the transport path. This will be accomplished by multiple model runs with emissions simulations switched on and off from the various source regions. To the greatest extent possible, model results will also be compared to field data collected at other air monitoring sites in the Ohio Valley region, operated independently of this project. These sites may include (1) the DOE National Energy Technologies Laboratory's monitoring site at its suburban Pittsburgh, PA facility; (2) sites in Pittsburgh (Lawrenceville) PA and Holbrook, PA operated by ATS; (3) sites in Steubenville, OH and Pittsburgh, PA operated by U.S. EPA and/or its contractors; and (4) sites operated by State or local air regulatory agencies. Field verification of model results and predictions will provide critical information for the development of cost effective air pollution control strategies by the coal-fired power plants in the Ohio River Valley region.« less
Kozar, M.D.; Brown, D.P.
1995-01-01
Ground-water-quality-monitoring sites have been established in compliance with the 1991 West Virginia "Groundwater Protection Act." One of the provisions of the "Groundwater Protection Act" is to conduct ground-water sampling, data collection, analyses, and evaluation with sufficient frequency so as to ascertain the characteristics and quality of ground water and the sufficiency of the ground- water protection programs established pursuant to the act (Chapter 20 of the code of West Virginia, 1991, Article 5-M). Information for 26 monitoring sites (wells and springs) which comprise the Statewide ambient ground-water-quality-monitoring network is presented. Areas in which monitoring sites were needed were determined by the West Virginia Division of Environmental Protection, Office of Water Resources in consultation with the U.S. Geological Survey (USGS). Initial sites were chosen on the basis of recent hydrogeologic investigations conducted by the USGS and from data stored in the USGS Ground Water Site Inventory database. Land use, aquifer setting, and areal coverage of the State are three of the more important criteria used in site selection. A field reconnaissance was conducted to locate and evaluate the adequacy of selected wells and springs. Descriptive information consisting of site, geologic, well construction, and aquifer-test data has been compiled. The 26 sites will be sampled periodically for iron, manganese, most common ions (for example, calcium, magnesium, sodium, potassium, sulfate, chloride, bicarbonate), volatile and semivolatile organic compounds (for example, pesticides and industrial solvents), and fecal coliform and fecal streptococcus bacteria. Background information explaining ground-water systems and water quality within the State has been included.
An extensive PM monitoring study was conducted during the 1998 Baltimore PM Epidemiology-Exposure Study of the Elderly. An exposure goal of this study was. to investigate the mass concentration variability between various monitoring instrumentation located across residential in...
Hadziioannou, Céline; Larose, Eric; Coutant, Olivier; Roux, Philippe; Campillo, Michel
2009-06-01
Previous studies have shown that small changes can be monitored in a scattering medium by observing phase shifts in the coda. Passive monitoring of weak changes through ambient noise correlation has already been applied to seismology, acoustics, and engineering. Usually, this is done under the assumption that a properly reconstructed Green function (GF), as well as stable background noise sources, is necessary. In order to further develop this monitoring technique, a laboratory experiment was performed in the 2.5 MHz range in a gel with scattering inclusions, comparing an active (pulse-echo) form of monitoring to a passive (correlation) one. Present results show that temperature changes in the medium can be observed even if the GF of the medium is not reconstructed. Moreover, this article establishes that the GF reconstruction in the correlations is not a necessary condition: The only condition to monitoring with correlation (passive experiment) is the relative stability of the background noise structure.
Alien liquid detector and control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potter, B.M.
An alien liquid detector employs a monitoring element and an energizing circuit for maintaining the temperature of the monitoring element substantially above ambient temperature. For this purpose an electronic circit controls a flow of heating current to the monitoring element. The presence of an alien liquid is detected by sensing a predetermined change in heating current flow to the monitoring element, e.g., to distinguish between water and oil. In preferred embodiments the monitoring element is a thermistor whose resistance is compared with a reference resistance and heating current through the thermistor is controlled in accordance with the difference. In onemore » embodiment a bridge circuit senses the resistance difference; the difference may be sensed by an operational amplifier arrangement. Features of the invention include positioning the monitoring element at the surface of water, slightly immersed, so that the power required to maintain the thermistor temperature substantially above ambient temperature serves to detect presence of oil pollution at the surface.« less
Banach, Marzena; Wasilewska, Agnieszka; Dlugosz, Rafal; Pauk, Jolanta
2018-05-18
Due to the problem of aging societies, there is a need for smart buildings to monitor and support people with various disabilities, including rheumatoid arthritis. The aim of this paper is to elaborate on novel techniques for wireless motion capture systems for the monitoring and rehabilitation of disabled people for application in smart buildings. The proposed techniques are based on cross-verification of distance measurements between markers and transponders in an environment with highly variable parameters. To their verification, algorithms that enable comprehensive investigation of a system with different numbers of transponders and varying ambient parameters (temperature and noise) were developed. In the estimation of the real positions of markers, various linear and nonlinear filters were used. Several thousand tests were carried out for various system parameters and different marker locations. The results show that localization error may be reduced by as much as 90%. It was observed that repetition of measurement reduces localization error by as much as one order of magnitude. The proposed system, based on wireless techniques, offers a high commercial potential. However, it requires extensive cooperation between teams, including hardware and software design, system modelling, and architectural design.
Mostafa, Salama A; Mustapha, Aida; Mohammed, Mazin Abed; Ahmad, Mohd Sharifuddin; Mahmoud, Moamin A
2018-04-01
Autonomous agents are being widely used in many systems, such as ambient assisted-living systems, to perform tasks on behalf of humans. However, these systems usually operate in complex environments that entail uncertain, highly dynamic, or irregular workload. In such environments, autonomous agents tend to make decisions that lead to undesirable outcomes. In this paper, we propose a fuzzy-logic-based adjustable autonomy (FLAA) model to manage the autonomy of multi-agent systems that are operating in complex environments. This model aims to facilitate the autonomy management of agents and help them make competent autonomous decisions. The FLAA model employs fuzzy logic to quantitatively measure and distribute autonomy among several agents based on their performance. We implement and test this model in the Automated Elderly Movements Monitoring (AEMM-Care) system, which uses agents to monitor the daily movement activities of elderly users and perform fall detection and prevention tasks in a complex environment. The test results show that the FLAA model improves the accuracy and performance of these agents in detecting and preventing falls. Copyright © 2018 Elsevier B.V. All rights reserved.
Weiss, Tobias; Schuster, Hubert; Müller, Johannes; Schaller, Karl-Heinz; Drexler, Hans; Angerer, Jürgen; Käfferlein, Heiko U
2011-10-01
Workers using composite materials by fibre reinforced laminate technology are exposed to 4,4'-methylenedianiline (MDA), a liver toxicant and suspected human carcinogen, during the production of rotor blades in helicopter industry. The aim of the study presented here was to assess the internal dose of MDA and the suitability of various personal protection measures at the workplace. Ambient monitoring and biological monitoring was carried out by analysing MDA in air and urine samples in seven workers of a highly specialized workplace (rotor blade production). Three different concepts of personal protection measures were applied to study the route of uptake and to evaluate strategies in decreasing workplace exposure. In addition, elimination kinetics of MDA was studied in three workers who were exposed to MDA on three consecutive working days. Ambient monitoring consistently provided air levels at or below the limit of quantification of 0.1 μg m(-3). Nevertheless, MDA was detected in 89% of all post-shift urine samples and median concentration was 4.2 μg l(-1). MDA in urine were >20 times higher than expected on data from ambient monitoring alone. A significant decrease in exposure could be achieved when workers have worn MDA-protective overalls in combination with MDA-protective gloves and a splash protection shield (from 9.8 μg l(-1) down to 3.7 μg l(-1)). The results show that MDA is taken up primarily via the skin at the workplaces under study. The excretion of MDA in urine was observed to be delayed after dermal exposure. Exposure assessment of MDA should be carried out by biological monitoring rather than ambient monitoring. For this purpose, urine samples midweek or at the end of the week should be used based on the observed delay in the excretion of MDA after dermal absorption. Uptake of MDA via the skin could not be completely avoided even if state-of-the-art personal protection measures were applied.
This paper provides preliminary information on the trends in ambient concentrations observed near a heavily traveled highway in Las Vegas, Nevada. As part of a joint effort by the U.S. Environmental Protection Agency (EPA) and Federal Highway Administration, an air monitoring pro...
40 CFR 58.16 - Data submittal and archiving requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Other Federal agencies may request access to filters for purposes of supporting air quality management... PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.16 Data submittal and..., via AQS all ambient air quality data and associated quality assurance data for SO2; CO; O3; NO2; NO...
We present several years of ambient ammonia, ammonium, hydrochloric acid, chloride, nitric acid, nitrate, nitrous acid, sulfur dioxide, and sulfate concentrations at a rural site in the Coastal Plain region of North Carolina. Also, the air chemistry of Lewiston, NC and Clinton, N...
METHODOLOGY OF AMBIENT AIR MONITORING FOR POLYCYCLIC AROMATIC HYDROCARBONS
In the last decade, several studies of polycyclic aromatic hydrocarbons (PAH) in ambient air in the U.S. specifically investigated (1) the sampling efficiency of two sorbents for PAH in air: XAD-2 and polyurethane foam (PUP); (2) the storage stability of PAH on quartz fiber fil...
Development and analysis of air quality modeling simulations for hazardous air pollutants
NASA Astrophysics Data System (ADS)
Luecken, D. J.; Hutzell, W. T.; Gipson, G. L.
The concentrations of five hazardous air pollutants were simulated using the community multi-scale air quality (CMAQ) modeling system. Annual simulations were performed over the continental United States for the entire year of 2001 to support human exposure estimates. Results are shown for formaldehyde, acetaldehyde, benzene, 1,3-butadiene and acrolein. Photochemical production in the atmosphere is predicted to dominate ambient formaldehyde and acetaldehyde concentrations, and to account for a significant fraction of ambient acrolein concentrations. Spatial and temporal variations are large throughout the domain over the year. Predicted concentrations are compared with observations for formaldehyde, acetaldehyde, benzene and 1,3-butadiene. Although the modeling results indicate an overall slight tendency towards underprediction, they reproduce episodic and seasonal behavior of pollutant concentrations at many monitors with good skill.
Martinez, Dani; Teixidó, Mercè; Font, Davinia; Moreno, Javier; Tresanchez, Marcel; Marco, Santiago; Palacín, Jordi
2014-03-27
This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.
Martinez, Dani; Teixidó, Mercè; Font, Davinia; Moreno, Javier; Tresanchez, Marcel; Marco, Santiago; Palacín, Jordi
2014-01-01
This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile. PMID:24681671
Analyses of electromagnetic and piezoelectric systems for efficient vibration energy harvesting
NASA Astrophysics Data System (ADS)
Hadas, Z.; Smilek, J.; Rubes, O.
2017-05-01
The paper deals with analyses and evaluation of vibration energy harvesting systems which are based on electromagnetic and piezoelectric physical principles off electro-mechanical conversion. Energy harvesting systems are associated with wireless sensors and a monitoring of engineering objects. The most of engineering objects operate with unwanted mechanical vibrations. However, vibrations could provide an ambient source of energy which is converted into useful electricity. The use of electromagnetic and piezoelectric vibration energy harvesters is analyzed in this paper. Thee evaluated output power is used for a choice of the efficient system with respect to the character of vibrations and thee required power output.
Characterization of ambient fine particles in the northwestern area and Anchorage, Alaska.
Kim, Eugene; Hopke, Philip K
2008-10-01
Ambient PM2.5 (particulate matter less than 2.5 microm in aerodynamic diameter) in the northwestern United States and Alaska is dominated by carbonaceous compounds associated with wood burning and transportation sources. PM2.5 source characterization studies analyzing recent PM2.5 speciation data have not been previously reported for these areas. In this study, ambient PM2.5 speciation samples collected at two monitoring sites located in the northwestern area, Olympic Peninsula, WA, and Portland, OR, and one monitoring site located in Anchorage, AK, were characterized through source apportionments. Gasoline vehicle, secondary sulfate, and wood smoke were the largest sources of PM2.5 collected at the Anchorage, Olympic, and Portland monitoring sites, respectively. Secondary sulfates showed an April peak at Anchorage and a November peak at Portland that are likely related to the increased photochemical reaction and long-range transport in Anchorage and meteorological stagnation in Portland. Secondary nitrate at the Olympic site showed a weak summer high peak that could be caused by seasonal tourism in the national park. Backward trajectories suggested that the elevated aged sea salt concentrations at the Portland monitoring site could be regional transport of sea salt that passed through other contaminated air sheds along the coast. Oil combustion emissions that might originate from ships and ferries were observed at the Olympic monitoring site.
Neurobehavioral effects of ambient air pollution on cognitive performance in US adults.
Chen, Jiu-Chiuan; Schwartz, Joel
2009-03-01
In vivo animal experiments demonstrate neurotoxicity of exposures to particulate matter (PM) and ozone, but only one small epidemiological study had linked ambient air pollution with central nervous system (CNS) functions in children. To examine the neurobehavioral effects associated with long-term exposure to ambient PM and ozone in adults. We conducted a secondary analysis of the Neurobehavioral Evaluation System-2 (NES2) data (including a simple reaction time test [SRTT] measuring motor response speed to a visual stimulus; a symbol-digit substitution test [SDST] for coding ability; and a serial-digit learning test [SDLT] for attention and short-term memory) from 1764 adult participants (aged 37.5+/-10.9 years) of the Third National Health and Nutrition Examination Survey in 1988-1991. Based on ambient PM(10) (PM with aerodynamic diameter <10microm) and ozone data from the EPA Aerometric Information Retrieval System database, estimated annual exposure prior to the examination were aggregated at the centroid of each census-block group of geocoded residences, using distance-weighted averages from all monitors in the residing and adjoining counties. Generalized linear models were constructed to examine the associations, adjusting for potential confounders. In age- and sex-adjusted models, PM(10) predicted reduced CNS functions, but the association disappeared after adjustment for sociodemographic factors. There were consistent associations between ozone and reduced performance in NES2. In models adjusting for demographics, socioeconomic status, lifestyle, household and neighborhood characteristics, and cardiovascular risk factors, ozone predicted high scores in SDST and SDLT, but not in SRTT. Each 10-ppb increase in annual ozone was associated with increased SDST and SDLT scores by 0.16 (95%CI: 0.01, 0.23) and 0.56 (95%CI: 0.07, 1.05), equivalent to 3.5 and 5.3 years of aging-related decline in cognitive performance. Our study provides the first epidemiological data supporting the adverse neurobehavioral effects of ambient air pollutants in adults.
A Cloud-Based Internet of Things Platform for Ambient Assisted Living
Cubo, Javier; Nieto, Adrián; Pimentel, Ernesto
2014-01-01
A common feature of ambient intelligence is that many objects are inter-connected and act in unison, which is also a challenge in the Internet of Things. There has been a shift in research towards integrating both concepts, considering the Internet of Things as representing the future of computing and communications. However, the efficient combination and management of heterogeneous things or devices in the ambient intelligence domain is still a tedious task, and it presents crucial challenges. Therefore, to appropriately manage the inter-connection of diverse devices in these systems requires: (1) specifying and efficiently implementing the devices (e.g., as services); (2) handling and verifying their heterogeneity and composition; and (3) standardizing and managing their data, so as to tackle large numbers of systems together, avoiding standalone applications on local servers. To overcome these challenges, this paper proposes a platform to manage the integration and behavior-aware orchestration of heterogeneous devices as services, stored and accessed via the cloud, with the following contributions: (i) we describe a lightweight model to specify the behavior of devices, to determine the order of the sequence of exchanged messages during the composition of devices; (ii) we define a common architecture using a service-oriented standard environment, to integrate heterogeneous devices by means of their interfaces, via a gateway, and to orchestrate them according to their behavior; (iii) we design a framework based on cloud computing technology, connecting the gateway in charge of acquiring the data from the devices with a cloud platform, to remotely access and monitor the data at run-time and react to emergency situations; and (iv) we implement and generate a novel cloud-based IoT platform of behavior-aware devices as services for ambient intelligence systems, validating the whole approach in real scenarios related to a specific ambient assisted living application. PMID:25093343
A cloud-based Internet of Things platform for ambient assisted living.
Cubo, Javier; Nieto, Adrián; Pimentel, Ernesto
2014-08-04
A common feature of ambient intelligence is that many objects are inter-connected and act in unison, which is also a challenge in the Internet of Things. There has been a shift in research towards integrating both concepts, considering the Internet of Things as representing the future of computing and communications. However, the efficient combination and management of heterogeneous things or devices in the ambient intelligence domain is still a tedious task, and it presents crucial challenges. Therefore, to appropriately manage the inter-connection of diverse devices in these systems requires: (1) specifying and efficiently implementing the devices (e.g., as services); (2) handling and verifying their heterogeneity and composition; and (3) standardizing and managing their data, so as to tackle large numbers of systems together, avoiding standalone applications on local servers. To overcome these challenges, this paper proposes a platform to manage the integration and behavior-aware orchestration of heterogeneous devices as services, stored and accessed via the cloud, with the following contributions: (i) we describe a lightweight model to specify the behavior of devices, to determine the order of the sequence of exchanged messages during the composition of devices; (ii) we define a common architecture using a service-oriented standard environment, to integrate heterogeneous devices by means of their interfaces, via a gateway, and to orchestrate them according to their behavior; (iii) we design a framework based on cloud computing technology, connecting the gateway in charge of acquiring the data from the devices with a cloud platform, to remotely access and monitor the data at run-time and react to emergency situations; and (iv) we implement and generate a novel cloud-based IoT platform of behavior-aware devices as services for ambient intelligence systems, validating the whole approach in real scenarios related to a specific ambient assisted living application.
Kaastrup, Kaja; Aguirre-Soto, Alan; Wang, Chen; Bowman, Christopher N; Stansbury, Jeffery; Sikes, Hadley D
In conjunction with a tertiary amine coinitiator, eosin, a photoreducible dye, has been shown to successfully circumvent oxygen inhibition in radical photopolymerization reactions. However, the role of O 2 in the initiation and polymerization processes remains inconclusive. Here, we employ a UV-Vis/FT-NIR analytical tool for real-time, simultaneous monitoring of chromophore and monomer reactive group concentrations to investigate the eosin-activated photopolymerization of PEGDA-based hydrogels under ambient conditions. First, we address the challenges associated with spectroscopic monitoring of the polymerization of hydrogels using UV-Vis and FT-NIR, proposing metrics for quantifying the extent of signal loss from reflection and scattering, and showing their relation to microgelation and network formation. Second, having established a method for extracting kinetic information by eliminating the effects of changing refractive index and scattering, the coupled UV-Vis/FT-NIR system is applied to the study of eosin-activated photopolymerization of PEGDA in the presence of O 2 . Analysis of the inhibition time, rate of polymerization, and rate of eosin consumption under ambient and purged conditions indicates that regeneration of eosin in the presence of oxygen and consumption of oxygen occur via a nonchain process. This suggests that the uniquely high O 2 resilience is due to alternative processes such as energy transfer from photo-activated eosin to oxygen. Uncovering the intricacies of the role of O 2 in eosin-mediated initiation aids the design of O 2 resistant free radical polymerization systems relevant to photonics, optoelectronics, biomaterials, and biosensing.
Kaastrup, Kaja; Aguirre-Soto, Alan; Wang, Chen; Bowman, Christopher N.; Stansbury, Jeffery; Sikes, Hadley D.
2016-01-01
In conjunction with a tertiary amine coinitiator, eosin, a photoreducible dye, has been shown to successfully circumvent oxygen inhibition in radical photopolymerization reactions. However, the role of O2 in the initiation and polymerization processes remains inconclusive. Here, we employ a UV-Vis/FT-NIR analytical tool for real-time, simultaneous monitoring of chromophore and monomer reactive group concentrations to investigate the eosin-activated photopolymerization of PEGDA-based hydrogels under ambient conditions. First, we address the challenges associated with spectroscopic monitoring of the polymerization of hydrogels using UV-Vis and FT-NIR, proposing metrics for quantifying the extent of signal loss from reflection and scattering, and showing their relation to microgelation and network formation. Second, having established a method for extracting kinetic information by eliminating the effects of changing refractive index and scattering, the coupled UV-Vis/FT-NIR system is applied to the study of eosin-activated photopolymerization of PEGDA in the presence of O2. Analysis of the inhibition time, rate of polymerization, and rate of eosin consumption under ambient and purged conditions indicates that regeneration of eosin in the presence of oxygen and consumption of oxygen occur via a nonchain process. This suggests that the uniquely high O2 resilience is due to alternative processes such as energy transfer from photo-activated eosin to oxygen. Uncovering the intricacies of the role of O2 in eosin-mediated initiation aids the design of O2 resistant free radical polymerization systems relevant to photonics, optoelectronics, biomaterials, and biosensing. PMID:26755925
Passive seismic monitoring of the Bering Glacier during its last surge event
NASA Astrophysics Data System (ADS)
Zhan, Z.
2017-12-01
The physical causes behind glacier surges are still unclear. Numerous evidences suggest that they probably involve changes in glacier basal conditions, such as switch of basal water system from concentrated large tunnels to a distributed "layer" as "connected cavities". However, most remote sensing approaches can not penetrate to the base to monitor such changes continuously. Here we apply seismic interferometry using ambient noise to monitor glacier seismic structures, especially to detect possible signatures of the hypothesized high-pressure water "layer". As an example, we derive an 11-year long history of seismic structure of the Bering Glacier, Alaska, covering its latest surge event. We observe substantial drops of Rayleigh and Love wavespeeds across the glacier during the surge event, potentially caused by changes in crevasse density, glacier thickness, and basal conditions.
NASA Astrophysics Data System (ADS)
Gill, R. A.; Campbell, C. S.; McQueen, S.; Isupov, T.; Walker, B. J.
2011-12-01
Forecasts predict that precipitation regimes in the western US will become more variable, with dry periods becoming more frequent and with individual rainfall events becoming more extreme. In water-limited ecosystems, increased event size may reduce soil moisture stress and increase net primary production (NPP), N mineralization (Nmin), and soil water content (Θ) and potential (Ψ). In more mesic systems, the increased time between rain events may increase soil moisture stress and reduce NPP, Nmin, Θ, and Ψ. To test this hypothesis, we experimentally altered the timing and size of rainfall events and reduced ambient rainfall during the growing season for xeric, low-elevation sites and mesic high-elevation sites. Research was conducted at the Great Basin Experimental Range in Ephraim Canyon, UT, USA. The experimental treatments were (1) ambient rain, (2) 30% reduction in ambient rain, (3) 70% reduction in ambient rain, (4) reapplication of ambient rain weekly, and (5) reapplication of ambient rain every 3 weeks. During this 3-year experiment (2009-2011), we monitored soil temperature and Θ, leaf area index and NDVI, N-mineralization, soil respiration, and aboveground NPP. We calculated Ψ using soil moisture release curves. To increase the temporal scope of our results we used the DAY-CENT ecosystem model to simulate century-long impacts of precipitation changes. We found production increased with larger, less-frequent precipitation events for both our xeric and mesic sites. Large rainfall events increased the duration of production where Ψ is more negative than critical water thresholds. There were no significant changes in N-availability with altered precipitation, but the modeling results suggest that drought is a much stronger control over N-availability than precipitation timing. Our results demonstrate that both xeric and mesic systems are highly sensitive to the timing and amount of precipitation.
Chien, T W; Chu, H; Hsu, W C; Tseng, T K; Hsu, C H; Chen, K Y
2003-08-01
The continuous emission monitoring system (CEMS) can monitor flue gas emissions continuously and instantaneously. However, it has the disadvantages of enormous cost, easily producing errors in sampling periods of bad weather, lagging response in variable ambient environments, and missing data in daily zero and span tests and maintenance. The concept of a predictive emission monitoring system (PEMS) is to use the operating parameters of combustion equipment through thermodynamic or statistical methods to construct a mathematic model that can predict emissions by a computer program. The goal of this study is to set up a PEMS in a gas-fired combined cycle power generation unit at the Hsinta station of Taiwan Power Co. The emissions to be monitored include nitrogen oxides (NOx) and oxygen (O2) in flue gas. The major variables of the predictive model were determined based on the combustion theory. The data of these variables then were analyzed to establish a regression model. From the regression results, the influences of these variables are discussed and the predicted values are compared with the CEMS data for accuracy. In addition, according to the cost information, the capital and operation and maintenance costs for a PEMS can be much lower than those for a CEMS.
Marschollek, Michael; Becker, Marcus; Bauer, Jürgen M; Bente, Petra; Dasenbrock, Lena; Elbers, Katharina; Hein, Andreas; Kolb, Gerald; Künemund, Harald; Lammel-Polchau, Christopher; Meis, Markus; Meyer Zu Schwabedissen, Hubertus; Remmers, Hartmut; Schulze, Mareike; Steen, Enno-Edzard; Thoben, Wilfried; Wang, Ju; Wolf, Klaus-Hendrik; Haux, Reinhold
2014-01-01
Demographic change will lead to a diminishing care workforce faced with rising numbers of older persons in need of care, suggesting meaningful use of health-enabling technologies, and home monitoring in particular, to contribute to supporting both the carers and the persons in need. We present and discuss the GAL-NATARS study design along with first results regarding technical feasibility of long-term home monitoring and acceptance of different sensor modalities. Fourteen geriatric participants with mobility-impairing fractures were recruited in three geriatric clinics. Following inpatient geriatric rehabilitation, their homes were equipped with ambient sensor components for three months. Additionally, a wearable accelerometer was employed. Technical feasibility was assessed by system and component downtimes, technology acceptance by face-to-face interviews. The overall system downtime was 6%, effected by two single events, but not by software failures. Technology acceptance was rated very high by all participants at the end of the monitoring periods, and no interference with their social lives was reported. Home-monitoring technologies were well-accepted by our participants. The information content of the data still needs to be evaluated with regard to clinical outcome parameters as well as the effect on the quality of life before recommending large-scale implementations.
Portable System for Monitoring the Microclimate in the Footwear-Foot Interface
Sandoval-Palomares, José de Jesús; Yáñez-Mendiola, Javier; Gómez-Espinosa, Alfonso; López-Vela, José Martin
2016-01-01
A new, continuously-monitoring portable device that monitors the diabetic foot has shown to help in reduction of diabetic foot complications. Persons affected by diabetic foot have shown to be particularly sensitive in the plantar surface; this sensitivity coupled with certain ambient conditions may cause dry skin. This dry skin leads to the formation of fissures that may eventually result in a foot ulceration and subsequent hospitalization. This new device monitors the micro-climate temperature and humidity areas between the insole and sole of the footwear. The monitoring system consists of an array of ten sensors that take readings of relative humidity within the range of 100% ± 2% and temperature within the range of −40 °C to 123.8 ± 0.3 °C. Continuous data is collected using embedded C software and the recorded data is processed in Matlab. This allows for the display of data; the implementation of the iterative Gauss-Newton algorithm method was used to display an exponential response curve. Therefore, the aim of our system is to obtain feedback data and provide the critical information to various footwear manufacturers. The footwear manufactures will utilize this critical information to design and manufacture diabetic footwear that reduce the risk of ulcers in diabetic feet. PMID:27399718
NASA Astrophysics Data System (ADS)
Cárdenas-Soto, M., Sr.; Hussain, Y.; Martinez-Carvajal, H., Sr.; Martino, S., Sr.; Rocha, M., Sr.
2016-12-01
Understanding the dynamics of stress relief mechanisms that lead to complete material collapse of unstable slopes is challenging. This research is focused on the novel use of Passive Ambient Noise Interferometry (PANI), a new technique that has revolutionized the seismology. In this technique the impulse response or Green function between two sensors is calculated by cross-correlation of the noise rescored at these stations. We applied PANI to monitor the deformational behavior of a prototype field experiment under semi controlled conditions for their use in landsliding early warning systems.The experimental setup consists of a 2 m engineering-scaled excavation,where induced failure was monitored by ambient vibrations propagating in tropical clayey deposits. The experimental setup consisted of dense network of 20 three components short period seismometers (Sercel L4C-3D) installed in three circular arrays with their distances from face of normal slope as 10, 20 and 30 meters, respectively.The frequency response of these seismometers is in range of 2-100 Hz. Recording was done in continuous mode at sampling rate of 1000 Hz with datalogger (RefTek DAS-130/3). Sensors were time synchronized by twenty 130 GPS/01. In this stage, the stress was applied on the one flank of this normal slope dug in the experimental field of University of Brasilia, by a hydraulic jack through a metallic plate. This incremental loading was kept on rising until the slope failure took place. This loading mechanism provided an opportunity to monitoring the changes in Rayleigh wave velocity before, during and after the complete failure. After initial processing, the green function (GF) or impulse response was calculated between each pair of sensors by cross correlation at time step of 4 second. All individual GFs, for entire monitoring period (30 minutes) were stacked to obtained a single reference GF. Stretching (dt/t) in waveform is calculated by subtracting individual GF from average GF, that gave Rayleigh wave velocity changes (dv/v=-dt/t). These changes correlated well with initiation and propagation of fracture at the face of this normal slope. It is concluded that cost effective technique, PANI has a good potential for the monitoring of time lapse changes of evolving fractures.
Noise-based seismic monitoring of the Campi Flegrei caldera
NASA Astrophysics Data System (ADS)
Zaccarelli, Lucia; Bianco, Francesca
2017-03-01
The Campi Flegrei caldera is one of the highest risk volcanic fields worldwide, because of its eruptive history and the large population hosted within the caldera. It experiences bradiseismic crises: sudden uplift with low energetic seismic swarm occurrences. No seismicity is recorded out of these deformation rate changes. Therefore, a continuous seismic monitoring of the caldera is possible only by means of the ambient seismic noise. We apply a noise-based seismic monitoring technique to the cross correlations of 5 year recordings at the mobile seismic network. The resulting relative velocity variations are compared to the temporal behavior of the geophysical and geochemical observations routinely sampled at Campi Flegrei. We discriminate between two kinds of crustal stress field variations acting at different timescales. They are related to a possible magmatic intrusion and to the gradual heating of the hydrothermal system, respectively. This study sets up the basis for future volcano monitoring strategies.
Summary of Ambient Air Monitoring in Southeast Chicago - Oct. 28, 2013
The monitoring station at George Washington High School reports pollutants including fine particulate matter, inhalable particulate matter, lead, and toxic metals. Data suggests sources including Beemsterboer and KCBX petcoke (petroleum coke) facilities.
EPA Protocol Gas Verification Program
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that co...
Source and long-term behavior of transuranic aerosols in the WIPP environment.
Thakur, P; Lemons, B G
2016-10-01
Source and long-term behavior transuranic aerosols ((239+240)Pu, (238)Pu, and (241)Am) in the ambient air samples collected at and near the Waste Isolation Pilot Plant (WIPP) deep geologic repository site were investigated using historical data from an independent monitoring program conducted by the Carlsbad Environmental Monitoring and Research Center and an oversight monitoring program conducted by the management and operating contractor for WIPP at and near the facility. An analysis of historical data indicates frequent detections of (239+240)Pu and (241)Am, whereas (238)Pu is detected infrequently. Peaks in (239+240)Pu and (241)Am concentrations in ambient air generally occur from March to June timeframe, which is when strong and gusty winds in the area frequently give rise to blowing dust. Long-term measurements of plutonium isotopes (1985-2015) in the WIPP environment suggest that the resuspension of previously contaminated soils is likely the primary source of plutonium in the ambient air samples from WIPP and its vicinity. There is no evidence that WIPP is a source of environmental contamination that can be considered significant by any health-based standard.
Overview of the new National Near-Road Air Quality Monitoring Network
In 2010, EPA promulgated new National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2). As part of this new NAAQS, EPA required the establishment of a national near-road air quality monitoring network. This network will consist of one NO2 near-road monitoring st...
40 CFR 58.10 - Annual monitoring network plan and periodic network assessment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Annual monitoring network plan and periodic network assessment. 58.10 Section 58.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.10 Annual...
40 CFR 58.10 - Annual monitoring network plan and periodic network assessment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Annual monitoring network plan and periodic network assessment. 58.10 Section 58.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.10 Annual...
Developments toward a Low-Cost Approach for Long-Term, Unattended Vapor Intrusion Monitoring
Tolley, William K.
2014-01-01
There are over 450,000 sites contaminated by chemicals in the US. This large number of contaminated sites and the speed of subsurface migration of chemicals pose considerable risk to nearby residences and commercial buildings. The high costs for monitoring around these site stem from the labor involved in placing and replacing the passive sorbent vapor samplers and the resultant laboratory analysis. This monitoring produces sparse data sets that do not track temporal changes well. To substantially reduce costs and better track exposures, less costly, unattended systems for monitoring soil gases and vapor intrusion into homes and businesses are desirable to aid in the remediation of contaminated sites. This paper describes progress toward the development of an inexpensive system specifically for monitoring vapor intrusion; the system can operate repeatedly without user intervention with low detection limits (1 × 10−9, or 1 part-per-billion). Targeted analytes include chlorinated hydrocarbons (dichloroethylene, trichloroethane, trichloroethylene, and perchloroethylene) and benzene. The system consists of a trap-and-purge preconcentrator for vapor collection in conjunction with a compact gas chromatography instrument to separate individual compounds. Chemical detection is accomplished with an array of chemicapacitors and a metal-oxide semiconductor combustibles sensor. Both the preconcentrator and the chromatography column are resistively heated. All components are compatible with ambient air, which serves as the carrier gas for the gas chromatography and detectors. PMID:24903107
Application of Smart Solid State Sensor Technology in Aerospace Applications
NASA Technical Reports Server (NTRS)
Hunter, Gary W.; Xu, Jennifer C.; Dungan, L.K.; Makel, D.; Ward, B.; Androjna, D.
2008-01-01
Aerospace applications require a range of chemical sensing technologies to monitor conditions in both space vehicles and aircraft operations. One example is the monitoring of oxygen. For example, monitoring of ambient oxygen (O2) levels is critical to ensuring the health, safety, and performance of humans living and working in space. Oxygen sensors can also be incorporated in detection systems to determine if hazardous leaks are occurring in space propulsion systems and storage facilities. In aeronautic applications, O2 detection has been investigated for fuel tank monitoring. However, as noted elsewhere, O2 is not the only species of interest in aerospace applications with a wide range of species of interest being relevant to understand an environmental or vehicle condition. These include combustion products such as CO, HF, HCN, and HCl, which are related to both the presence of a fire and monitoring of post-fire clean-up operations. This paper discusses the development of an electrochemical cell platform based on a polymer electrolyte, NAFION, and a three-electrode configuration. The approach has been to mature this basic platform for a range of applications and to test this system, combined with "Lick and Stick" electronics, for its viability to monitor an environment related to astronaut crew health and safety applications with an understanding that a broad range of applications can be addressed with a core technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-23
... a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Methods... announcing a public teleconference on September 15, 2010, of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Monitoring & Methods Subcommittee (AAMMS or Subcommittee) to provide advice on EPA's...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... Hydrogen Peroxide Filter Extraction'' In this method, total suspended particulate matter (TSP) is collected on glass fiber filters according to 40 CFR Appendix G to part 50, EPA Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From Ambient Air. The filter samples are...
Human exposure to air pollution in many studies is represented by ambient concentrations from space-time kriging of observed values. Space-time kriging techniques based on a limited number of ambient monitors may fail to capture the concentration from local sources. Further, beca...
Scientists from the United States and the Czech Republic recently completed a study to investigate the ambient air quality impact of industrial and motor vehicle sources in Teplice. ir pollution measurements made from 1992 through 1993 provide data on ambient concentrations of su...
Oak Ridge Reservation annual site environmental report for 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koncinski, W.S.
1996-09-01
This report presents the details of the environmental monitoring and management program for the Oak Ridge Reservation. Topics discussed include: site background, climate, and operations; environmental compliance strategies; effluent monitoring; environmental management program including environmental restoration, decontamination and decommissioning, technology development, and public involvement; effluent monitoring of airborne discharges, liquid discharges, toxicity control and monitoring, biological monitoring and abatement; environmental surveillance which encompasses meteorological monitoring, ambient air monitoring, surface water monitoring, soils monitoring, sediment monitoring, and contamination of food stuffs monitoring; radiation doses; chemical exposures; ground water monitoring; and quality assurance.
Stanton, Gregory P.; Thomas, Jonathan V.; Stoval, Jeffery
2009-01-01
Logs collected in monitoring well PTX06–1068 during ambient conditions indicate a static environment with no flow. During pumping there was upward vertical flow at rates ranging from 0.4 to 4.8 gallons per minute. During pumping, a gradual trend of more positive flowmeter values (upward flow) with distance up the well was observed. Estimated total transmissivity for four production zones identified from Flow–B numerical model results taken together was calculated to be about 200 feet squared per day.
Steam generator on-line efficiency monitor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, R.K.; Kaya, A.; Keyes, M.A. IV
1987-08-04
This patent describes a system for automatically and continuously determining the efficiency of a combustion process in a fossil-fuel fired vapor generator for utilization by an automatic load control system that controls the distribution of a system load among a plurality of vapor generators, comprising: a first function generator, connected to an oxygen transducer for sensing the level of excess air in the flue gas, for generating a first signal indicative of the total air supplied for combustion in percent by weight; a second function generator, connected to a combustibles transducer for sensing the level of combustibles in the fluemore » gas, for generating a second signal indicative of the percent combustibles present in the flue gas; means for correcting the first signal, connected to the first and second function generators, when the oxygen transducer is of a type that operates at a temperature level sufficient to cause the unburned combustibles to react with the oxygen present in the flue gas; an ambient air temperature transducer for generating a third signal indicative of the temperature of the ambient air supplied to the vapor generator for combustion.« less
Development of an electronic nose for environmental odour monitoring.
Dentoni, Licinia; Capelli, Laura; Sironi, Selena; Del Rosso, Renato; Zanetti, Sonia; Della Torre, Matteo
2012-10-25
Exhaustive odour impact assessment should involve the evaluation of the impact of odours directly on citizens. For this purpose it might be useful to have an instrument capable of continuously monitoring ambient air quality, detecting the presence of odours and also recognizing their provenance. This paper discusses the laboratory and field tests conducted in order to evaluate the performance of a new electronic nose, specifically developed for monitoring environmental odours. The laboratory tests proved the instrument was able to discriminate between the different pure substances being tested, and to estimate the odour concentrations giving correlation indexes (R2) of 0.99 and errors below 15%. Finally, the experimental monitoring tests conducted in the field, allowed us to verify the effectiveness of this electronic nose for the continuous detection of odours in ambient air, proving its stability to variable atmospheric conditions and its capability to detect odour peaks.
Marciniuk, Darcy
2016-01-01
The challenges of providing quality respiratory care to persons living in rural or remote communities can be daunting. These populations are often vulnerable in terms of both health status and access to care, highlighting the need for innovation in service delivery. The rapidly expanding options available using telehealthcare technologies have the capacity to allow patients in rural and remote communities to connect with providers at distant sites and to facilitate the provision of diagnostic, monitoring, and therapeutic services. Successful implementation of telehealthcare programs in rural and remote settings is, however, contingent upon accounting for key technical, organizational, social, and legal considerations at the individual, community, and system levels. This review article discusses five types of telehealthcare delivery that can facilitate respiratory care for residents of rural or remote communities: remote monitoring (including wearable and ambient systems; remote consultations (between providers and between patients and providers), remote pulmonary rehabilitation, telepharmacy, and remote sleep monitoring. Current and future challenges related to telehealthcare are discussed. PMID:26902542
Brown, Andrew S; Brown, Richard J C; Coleman, Peter J; Conolly, Christopher; Sweetman, Andrew J; Jones, Kevin C; Butterfield, David M; Sarantaridis, Dimitris; Donovan, Brian J; Roberts, Ian
2013-06-01
The impact of human activities on the health of the population and of the wider environment has prompted action to monitor the presence of toxic compounds in the atmosphere. Toxic organic micropollutants (TOMPs) are some of the most insidious and persistent of these pollutants. Since 1991 the United Kingdom has operated nationwide air quality networks to assess the presence of TOMPs, including polycyclic aromatic hydrocarbons (PAHs), in ambient air. The data produced in 2010 marked 20 years of nationwide PAH monitoring. This paper marks this milestone by providing a novel and critical review of the data produced since nationwide monitoring began up to the end of 2011 (the latest year for which published data is available), discussing how the networks performing this monitoring has evolved, and elucidating trends in the concentrations of the PAHs measured. The current challenges in the area and a forward look to the future of air quality monitoring for PAHs are also discussed briefly.
NASA Astrophysics Data System (ADS)
Mehta, Sumi; Sbihi, Hind; Dinh, Tuan Nguyen; Xuan, Dan Vu; Le Thi Thanh, Loan; Thanh, Canh Truong; Le Truong, Giang; Cohen, Aaron; Brauer, Michael
2014-10-01
Socioeconomic factors often affect the distribution of exposure to air pollution. The relationships between health, air pollution, and poverty potentially have important public health and policy implications, especially in areas of Asia where air pollution levels are high and income disparity is large. The objective of the study was to characterize the levels, determinants of exposure, and relationships between children personal exposures and ambient concentrations of multiple air pollutants amongst different socioeconomic segments of the population of Ho Chi Minh City, Vietnam. Using repeated (N = 9) measures personal exposure monitoring and determinants of exposure modeling, we compared daily average PM2.5, PM10, PM2.5 absorbance and NO2 concentrations measured at ambient monitoring sites to measures of personal exposures for (N = 64) caregivers of young children from high and low socioeconomic groups in two districts (urban and peri-urban), across two seasons. Personal exposures for both PM sizes were significantly higher among the poor compared to non-poor participants in each district. Absolute levels of personal exposures were under-represented by ambient monitors with median individual longitudinal correlations between personal exposures and ambient concentrations of 0.4 for NO2, 0.6 for PM2.5 and PM10 and 0.7 for absorbance. Exposures of the non-poor were more highly correlated with ambient concentrations for both PM size fractions and absorbance while those for NO2 were not significantly affected by socioeconomic position. Determinants of exposure modeling indicated the importance of ventilation quality, time spent in the kitchen, air conditioner use and season as important determinant of exposure that are not fully captured by the differences in socioeconomic position. Our results underscore the need to evaluate how socioeconomic position affects exposure to air pollution. Here, differential exposure to major sources of pollution, further influenced by characteristics of Ho Chi Minh City's rapidly urbanizing landscape, resulted in systematically higher PM exposures among the poor.
Digital radiography in general dental practice: a field study.
Hellén-Halme, K; Nilsson, M; Petersson, A
2007-07-01
The aim of this study was to conduct a field study to survey the performance of digital radiography and how it was used by dentists in general dental practice. 19 general dental practitioners were visited at their clinics. Ambient light (illuminance) was measured in the rooms where the monitors were placed. Different technical display parameters were noted. Test images and two phantoms--one low-contrast phantom and one line-pair resolution phantom--were used to evaluate the digital system. How the dentists used the enhancement program was investigated by noting which functions were used. Average illuminance in the operating room was 668 lux (range 190-1250 lux). On radiographs of the low-contrast phantom taken at the clinic, the ability to observe the holes decreased as illuminance increased. On average, the "light percentage" initially set on the monitor had to be decreased by 17% and contrast by 10% to optimize the display of the test images. The general dental practitioners used the enhancement programs most often to alter brightness and contrast to obtain the subjectively best image. Large differences between the clinics were noted. Knowledge of how to handle digital equipment in general dental practice should be improved. A calibrated monitor of good quality should be a given priority, as should proper ambient light conditions. There is a need to develop standardized quality controls for digital dental radiography.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-11
...EPA is proposing to make two determinations regarding the tri- state Huntington-Ashland, West Virginia-Kentucky-Ohio fine particulate matter (PM2.5) nonattainment Area (hereafter referred to as ``the Huntington-Ashland Area'' or ``Area''). First, EPA is proposing to determine that the Area has attained the 1997 annual average PM2.5 National Ambient Air Quality Standard (NAAQS). This proposed determination of attainment is based upon complete, quality- assured and certified ambient air monitoring data for the 2007-2009 period showing that the Area has attained the 1997 annual PM2.5 NAAQS, and data available to date for 2010 in EPA's Air Quality System (AQS) database that show the area continues to attain. If EPA finalizes this proposed determination of attainment, the requirements for the Area to submit attainment demonstrations and associated reasonably available control measures (RACM), a reasonable further progress (RFP) plan, contingency measures, and other planning State Implementation Plan (SIP) revisions related to attainment of the standard shall be suspended for so long as the Area continues to attain the annual PM2.5 NAAQS. Second, EPA is also proposing to determine, based on quality-assured and certified monitoring data for the 2007-2009 monitoring period, that the Area has attained the 1997 annual PM2.5 NAAQS by its applicable attainment date of April 5, 2010.
Olsen, Lisa D.; Valder, Joshua F.; Carter, Janet M.; Zogorski, John S.
2013-01-01
A total of 2,541 constituents were evaluated and prioritized for national- and regional-scale ambient monitoring of water and sediment in the United States. This prioritization was done by the U.S. Geological Survey (USGS) in preparation for the upcoming third decade (Cycle 3; 2013–23) of the National Water-Quality Assessment (NAWQA) Program. This report provides the methods used to prioritize the constituents and the results of that prioritization. Constituents were prioritized by the NAWQA National Target Analyte Strategy (NTAS) work group on the basis of available information on physical and chemical properties, observed or predicted environmental occurrence and fate, and observed or anticipated adverse effects on human health or aquatic life. Constituents were evaluated within constituent groups that were determined on the basis of physical or chemical properties or on uses or sources. Some constituents were evaluated within more than one constituent group. Although comparable objectives were used in the prioritization of constituents within the different constituent groups, differences in the availability of information accessed for each constituent group led to the development of separate prioritization approaches adapted to each constituent group to make best use of available resources. Constituents were assigned to one of three prioritization tiers: Tier 1, those having the highest priority for inclusion in ambient monitoring of water or sediment on a national or regional scale (including NAWQA Cycle 3 monitoring) on the basis of their likelihood of environmental occurrence in ambient water or sediment, or likelihood of effects on human health or aquatic life; Tier 2, those having intermediate priority for monitoring on the basis of their lower likelihood of environmental occurrence or lower likelihood of effects on human health or aquatic life; and Tier 3, those having low or no priority for monitoring on the basis of evidence of nonoccurrence or lack of effects on human health or aquatic life, or of having insufficient evidence of potential occurrence or effects to justify placement into Tier 2. Of the 1,081 constituents determined to be of highest priority for ambient monitoring (Tier 1), 602 were identified for water and 686 were identified for sediment (note that some constituents were evaluated for both water and sediment). These constituents included various types of organic compounds, trace elements and other inorganic constituents, and radionuclides. Some of these constituents are difficult to analyze, whereas others are mixtures, isomers, congeners, salts, and acids of other constituents; therefore, modifications to the list of high-priority constituents for ambient monitoring could be made on the basis of the availability of suitable methods for preparation, extraction, or analysis. An additional 1,460 constituents were placed into Tiers 2 or 3 for water or sediment, including some constituents that had been placed into Tier 1 for a different matrix; 436 constituents were placed into Tier 2 for water and 246 constituents into Tier 2 for sediment; 979 constituents were placed into Tier 3 for water and 779 constituents into Tier 3 for sediment.
NASA Astrophysics Data System (ADS)
Kato, H.
2015-12-01
We investigated the transfer of canopy-intercepted radiocesium to the forest floor during 3 years following the Fukushima Daiichi Nuclear Power Plant accident. The cesium-137 (Cs-137) contents in throughfall, stemflow, and litterfall were monitored in two coniferous stands (plantation of Japanese cedar) and a deciduous broad-leaved forest stand (Japanese oak with red pine). We also measured the ambient dose rate (ADR) at different heights in the forest using a survey meter and a portable Ge gamma-ray detector. Total Cs-137 deposition flux from the canopy to forest floor for the mature cedar, young cedar, and the mixed broad-leaved stands were 166 kBq/m2, 174 kBq/m2, and 60 kBq/m2, respectively. These values correspond to 38%, 40% and 13% of total atmospheric input after the accident. The ambient dose rate in forest exhibited height dependency and its vertical distribution varied with forest type and stand age. The ambient dose rate showed an exponential decrease with time for all the forest sites, however the decreasing trend differed depending on the height of dose measurement and forest type. The ambient dose rate at the canopy (approx. 10 m-height) decreased faster than that expected from physical decay of the two radiocesium isotopes, whereas those at the forest floor varied between the three forest stands. The radiocesium deposition via throughfall seemed to increase ambient dose rate during the first 200 days after the accident, however there was no clear relationship between litterfall and ambient dose rate since 400 days after the accident. These data suggested that the ambient dose rate in forest environment varied both spatially and temporally reflecting the transfer of radiocesium from canopy to forest floor. However, further monitoring investigation and analysis are required to determine the effect of litterfall on long-term trend of ambient dose rate in forest environments.
NASA Technical Reports Server (NTRS)
King, R. B.; Fordyce, J. S.; Antoine, A. C.; Leibecki, H. F.; Neustadter, H. E.; Sidik, S. M.; Burr, J. C.; Craig, G. T.; Cornett, C. L.
1974-01-01
Preliminary review of a study of trace elements and compound concentrations in the ambient suspended particulate matter in Cleveland, Ohio, measured from August 1971 through June 1973, as a function of source, monitoring location, and meteorological conditions. The study is aimed at the development of techniques for identifying specific pollution sources which could be integrated into a practical system readily usable by an enforcement agency.
Determination of beryllium concentrations in UK ambient air
NASA Astrophysics Data System (ADS)
Goddard, Sharon L.; Brown, Richard J. C.; Ghatora, Baljit K.
2016-12-01
Air quality monitoring of ambient air is essential to minimise the exposure of the general population to toxic substances such as heavy metals, and thus the health risks associated with them. In the UK, ambient air is already monitored under the UK Heavy Metals Monitoring Network for a number of heavy metals, including nickel (Ni), arsenic (As), cadmium (Cd) and lead (Pb) to ensure compliance with legislative limits. However, the UK Expert Panel on Air Quality Standards (EPAQS) has highlighted a need to limit concentrations of beryllium (Be) in air, which is not currently monitored, because of its toxicity. The aim of this work was to analyse airborne particulate matter (PM) sampled onto filter papers from the UK Heavy Metals Monitoring Network for quantitative, trace level beryllium determination and compare the results to the guideline concentration specified by EPAQS. Samples were prepared by microwave acid digestion in a matrix of 2% sulphuric acid and 14% nitric acid, verified by the use of Certified Reference Materials (CRMs). The digested samples were then analysed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The filters from the UK Heavy Metals Monitoring Network were tested using this procedure and the average beryllium concentration across the network for the duration of the study period was 7.87 pg m-3. The highest site average concentration was 32.0 pg m-3 at Scunthorpe Low Santon, which is significantly lower than levels that are thought to cause harm. However the highest levels were observed at sites monitoring industrial point sources, indicating that beryllium is being used and emitted, albeit at very low levels, from these point sources. Comparison with other metals concentrations and data from the UK National Atmospheric Emissions Inventory suggests that current emissions of beryllium may be significantly overestimated.
GENASIS national and international monitoring networks for persistent organic pollutants
NASA Astrophysics Data System (ADS)
Brabec, Karel; Dušek, Ladislav; Holoubek, Ivan; Hřebíček, Jiří; Kubásek, Miroslav; Urbánek, Jaroslav
2010-05-01
Persistent organic pollutants (POPs) remain in the centre of scientific attention due to their slow rates of degradation, their toxicity, and potential for both long-range transport and bioaccumulation in living organisms. This group of compounds covers large number of various chemicals from industrial products, such as polychlorinated biphenyls, etc. The GENASIS (Global Environmental Assessment and Information System) information system utilizes data from national and international monitoring networks to obtain as-complete-as-possible set of information and a representative picture of environmental contamination by persistent organic pollutants (POPs). There are data from two main datasets on POPs monitoring: 1.Integrated monitoring of POPs in Košetice Observatory (Czech Republic) which is a long term background site of the European Monitoring and Evaluation Programme (EMEP) for the Central Europe; the data reveals long term trends of POPs in all environmental matrices. The Observatory is the only one in Europe where POPs have been monitored not only in ambient air, but also in wet atmospheric deposition, surface waters, sediments, soil, mosses and needles (integrated monitoring). Consistent data since the year 1996 are available, earlier data (up to 1998) are burdened by high variability and high detection limits. 2.MONET network is ambient air monitoring activities in the Central and Eastern European region (CEEC), Central Asia, Africa and Pacific Islands driven by RECETOX as the Regional Centre of the Stockholm Convention for the region of Central and Eastern Europe under the common name of the MONET networks (MONitoring NETwork). For many of the participating countries these activities generated first data on the atmospheric levels of POPs. The MONET network uses new technologies of air passive sampling, which was developed, tested, and calibrated by RECETOX in cooperation with Environment Canada and Lancaster University, and was originally launched as a model monitoring network providing public administration, private subject, and general public information about air pollution by POPs that had not been previously regularly monitored and whose measurement is further required by global monitoring plan of the Stockholm Convention. The MONET network is international project with many participants. Monitoring in the MONET-CZ network started in 2004 with the pilot project and continues to the current days, MONET CEEC started in 2006 and continues nowadays, MONET Africa started in 2008. The database of the GENASIS systems currently covers MONET-CZ data until the year 2008. The MONET network currently covers 37 countries in the Europe, Asia and Africa with more than 350 sampling sites. The paper will discuss about following topics * Data Fusion in GENASIS: how can GENASIS maximize the value and accuracy of the information gathered from heterogeneous data sources? * Sensor types in GENASIS: which POPs can be measured; what are the physical limitations to achievable accuracy, reliability, and long-term stability of miniaturized sensors; which applications can (not) be realized within these limitations?
Acoustic-wave sensor for ambient monitoring of a photoresist-stripping agent
Pfeifer, K.B.; Hoyt, A.E.; Frye, G.C.
1998-08-18
The acoustic-wave sensor is disclosed. The acoustic-wave sensor is designed for ambient or vapor-phase monitoring of a photoresist-stripping agent such as N-methylpyrrolidinone (NMP), ethoxyethylpropionate (EEP) or the like. The acoustic-wave sensor comprises an acoustic-wave device such as a surface-acoustic-wave (SAW) device, a flexural-plate-wave (FPW) device, an acoustic-plate-mode (APM) device, or a thickness-shear-mode (TSM) device (also termed a quartz crystal microbalance or QCM) having a sensing region on a surface thereof. The sensing region includes a sensing film for sorbing a quantity of the photoresist-stripping agent, thereby altering or shifting a frequency of oscillation of an acoustic wave propagating through the sensing region for indicating an ambient concentration of the agent. According to preferred embodiments of the invention, the acoustic-wave device is a SAW device; and the sensing film comprises poly(vinylacetate), poly(N-vinylpyrrolidinone), or poly(vinylphenol). 3 figs.
Acoustic-wave sensor for ambient monitoring of a photoresist-stripping agent
Pfeifer, Kent B.; Hoyt, Andrea E.; Frye, Gregory C.
1998-01-01
The acoustic-wave sensor. The acoustic-wave sensor is designed for ambient or vapor-phase monitoring of a photoresist-stripping agent such as N-methylpyrrolidinone (NMP), ethoxyethylpropionate (EEP) or the like. The acoustic-wave sensor comprises an acoustic-wave device such as a surface-acoustic-wave (SAW) device, a flexural-plate-wave (FPW) device, an acoustic-plate-mode (APM) device, or a thickness-shear-mode (TSM) device (also termed a quartz crystal microbalance or QCM) having a sensing region on a surface thereof. The sensing region includes a sensing film for sorbing a quantity of the photoresist-stripping agent, thereby altering or shifting a frequency of oscillation of an acoustic wave propagating through the sensing region for indicating an ambient concentration of the agent. According to preferred embodiments of the invention, the acoustic-wave device is a SAW device; and the sensing film comprises poly(vinylacetate), poly(N-vinylpyrrolidinone), or poly(vinylphenol).
National Trends in Trace Metals Concentrations in Ambient Particulate Matter
NASA Astrophysics Data System (ADS)
McCarthy, M. C.; Hafner, H. R.; Charrier, J. G.
2007-12-01
Ambient measurements of trace metals identified as hazardous air pollutants (HAPs, air toxics) collected in the United States from 1990 to 2006 were analyzed for long-term trends. Trace metals analyzed include lead, manganese, arsenic, chromium, nickel, cadmium, and selenium. Visual and statistical analyses were used to identify and quantify temporal variations in air toxics at national and regional levels. Trend periods were required to be at least five years. Lead particles decreased in concentration at most monitoring sites, but trends in other metals were not consistent over time or spatially. In addition, routine ambient monitoring methods had method detection limits (MDLs) too high to adequately measure concentrations for trends analysis. Differences between measurement methods at urban and rural sites also confound trends analyses. Improvements in MDLs, and a better understanding of comparability between networks, are needed to better quantify trends in trace metal concentrations in the future.
Monitoring and evaluating civil structures using measured vibration
NASA Astrophysics Data System (ADS)
Straser, Erik G.; Kiremidjian, Anne S.
1996-04-01
The need for a rapid assessment of the state of critical and conventional civil structures, such as bridges, control centers, airports, and hospitals, among many, has been amply demonstrated during recent natural disasters. Research is underway at Stanford University to develop a state-of-the-art automated damage monitoring system for long term and extreme event monitoring based on both ambient and forced response measurements. Such research requires a multi-disciplinary approach harnessing the talents and expertise of civil, electrical, and mechanical engineering to arrive at a novel hardware and software solution. Recent advances in silicon micro-machining and microprocessor design allow for the economical integration of sensing, processing, and communication components. Coupling these technological advances with parameter identification algorithms allows for the realization of extreme event damage monitoring systems for civil structures. This paper addresses the first steps toward the development of a near real-time damage diagnostic and monitoring system based on structural response to extreme events. Specifically, micro-electro-mechanical- structures (MEMS) and microcontroller embedded systems (MES) are demonstrated to be an effective platform for the measurement and analysis of civil structures. Experimental laboratory tests with small scale model specimens and a preliminary sensor module are used to evaluate hardware and obtain structural response data from input accelerograms. A multi-step analysis procedure employing ordinary least squares (OLS), extended Kalman filtering (EKF), and a substructuring approach is conducted to extract system characteristics of the model. Results from experimental tests and system identification (SI) procedures as well as fundamental system design issues are presented.
Human Activity Recognition in AAL Environments Using Random Projections.
Damaševičius, Robertas; Vasiljevas, Mindaugas; Šalkevičius, Justas; Woźniak, Marcin
2016-01-01
Automatic human activity recognition systems aim to capture the state of the user and its environment by exploiting heterogeneous sensors attached to the subject's body and permit continuous monitoring of numerous physiological signals reflecting the state of human actions. Successful identification of human activities can be immensely useful in healthcare applications for Ambient Assisted Living (AAL), for automatic and intelligent activity monitoring systems developed for elderly and disabled people. In this paper, we propose the method for activity recognition and subject identification based on random projections from high-dimensional feature space to low-dimensional projection space, where the classes are separated using the Jaccard distance between probability density functions of projected data. Two HAR domain tasks are considered: activity identification and subject identification. The experimental results using the proposed method with Human Activity Dataset (HAD) data are presented.
Human Activity Recognition in AAL Environments Using Random Projections
Damaševičius, Robertas; Vasiljevas, Mindaugas; Šalkevičius, Justas; Woźniak, Marcin
2016-01-01
Automatic human activity recognition systems aim to capture the state of the user and its environment by exploiting heterogeneous sensors attached to the subject's body and permit continuous monitoring of numerous physiological signals reflecting the state of human actions. Successful identification of human activities can be immensely useful in healthcare applications for Ambient Assisted Living (AAL), for automatic and intelligent activity monitoring systems developed for elderly and disabled people. In this paper, we propose the method for activity recognition and subject identification based on random projections from high-dimensional feature space to low-dimensional projection space, where the classes are separated using the Jaccard distance between probability density functions of projected data. Two HAR domain tasks are considered: activity identification and subject identification. The experimental results using the proposed method with Human Activity Dataset (HAD) data are presented. PMID:27413392
Network-Oriented Radiation Monitoring System (NORMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahmat Aryaeinejad; David F. Spencer
2007-10-01
We have developed a multi-functional pocket radiation monitoring system capable of detecting and storing gamma ray and neutron data and then sending the data through a wireless connection to a remote central facility upon request. The device has programmable alarm trigger levels that can be modified for specific applications. The device could be used as a stand-alone device or in conjunction with an array to cover a small or large area. The data is stored with a date/time stamp. The device may be remotely configured. Data can be transferred and viewed on a PDA via direct connection or wirelessly. Functional/benchmore » tests have been completed successfully. The device detects low-level neutron and gamma sources within a shielded container in a radiation field of 10 uR/hr above the ambient background level.« less
40 CFR 52.74 - Original identification of plan section.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Governor of Alaska on January 18, 1980 as follows: Volume II. Analysis of Problems, Control Actions Section... requirements of Air Quality Monitoring, 40 CFR part 58, subpart C, § 58.20, as follows: Volume II. Analysis of Problems, Control Actions Section V. Ambient Air Monitoring A. Purpose C. Air Monitoring Network E. Annual...
40 CFR 52.70 - Identification of plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... submitted by the Governor of Alaska on January 18, 1980 as follows: Volume II. Analysis of Problems, Control... requirements of Air Quality Monitoring, 40 CFR part 58, subpart C, § 58.20, as follows: Volume II. Analysis of Problems, Control Actions Section V. Ambient Air Monitoring A. Purpose C. Air Monitoring Network E. Annual...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
... completeness requirement for one or more quarters during 2009-2011. EPA addressed the missing data of each of...-assured, quality-controlled and certified ambient air monitoring data for the 2008-2010 and 2009-2011...- assured, quality-controlled, and certified monitoring data for the 2007-2009 monitoring period, that the...
2018 EPA Protocol Gas Verification Program Participants
A list of participants for 2016 EPA's Protocol Gas Verification Program (PGVP) for stationary source monitoring. The list also has vendor IDs, which are production site-specific, and are the same ones used in the PGVP for ambient air monitoring.
Current Status of EPA Protocol Gas Verification Program
Accurate compressed gas reference standards are needed to calibrate and audit continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensur...
Systemic inflammation, heart rate variability and air pollution in a cohort of senior adults.
Luttmann-Gibson, Heike; Suh, Helen H; Coull, Brent A; Dockery, Douglas W; Sarnat, Stefanie Ebelt; Schwartz, Joel; Stone, Peter H; Gold, Diane R
2010-09-01
Short-term elevation of ambient particulate air pollution has been associated with autonomic dysfunction and increased systemic inflammation, but the interconnections between these pathways are not well understood. We examined the association between inflammation and autonomic dysfunction and effect modification of inflammation on the association between air pollution and heart rate variability (HRV) in elderly subjects. 25 elderly subjects in Steubenville, Ohio, were followed up to 24 times with repeated 30-min ECG Holter monitoring (545 observations). C-reactive protein (CRP), fibrinogen, interleukin-6 (IL-6), soluble inter-cellular adhesion molecule 1 (sICAM-1), and white blood cell and platelet counts were measured in peripheral blood samples collected in the first month of the study. Increased systemic inflammation was defined for subjects within the upper 20% of the distribution for each marker. A central ambient monitoring station provided daily fine particle (PM(2.5)) and sulphate (SO(4)(2-)) data. Linear mixed models were used to identify associations between inflammatory markers and HRV and to assess effect modification of the association between air pollution and HRV due to inflammatory status. A 5.8 mg/l elevation in CRP was associated with decreases of between -8% and -33% for time and frequency domain HRV outcomes. A 5.1 microg/m(3) increase in SO(4)(2-) on the day before the health assessment was associated with a decrease of -6.7% in the SD of normal RR intervals (SDNN) (95% CI -11.8% to -1.3%) in subjects with elevated CRP, but not in subjects with lower CRP (p value interaction=0.04), with similar findings for PM(2.5). Increased systemic inflammation is associated with autonomic dysfunction in the elderly. Air pollution effects on reduced SDNN are stronger in subjects with elevated systemic inflammation.
Monitoring of PM10 and PM2.5 around primary particulate anthropogenic emission sources
NASA Astrophysics Data System (ADS)
Querol, Xavier; Alastuey, Andrés; Rodriguez, Sergio; Plana, Felicià; Mantilla, Enrique; Ruiz, Carmen R.
Investigations on the monitoring of ambient air levels of atmospheric particulates were developed around a large source of primary anthropogenic particulate emissions: the industrial ceramic area in the province of Castelló (Eastern Spain). Although these primary particulate emissions have a coarse grain-size distribution, the atmospheric transport dominated by the breeze circulation accounts for a grain-size segregation, which results in ambient air particles occurring mainly in the 2.5-10 μm range. The chemical composition of the ceramic particulate emissions is very similar to the crustal end-member but the use of high Al, Ti and Fe as tracer elements as well as a peculiar grain-size distribution in the insoluble major phases allow us to identify the ceramic input in the bulk particulate matter. PM2.5 instead of PM10 monitoring may avoid the interference of crustal particles without a major reduction in the secondary anthropogenic load, with the exception of nitrate. However, a methodology based in PM2.5 measurement alone is not adequate for monitoring the impact of primary particulate emissions (such as ceramic emissions) on air quality, since the major ambient air particles derived from these emissions are mainly in the range of 2.5-10 μm. Consequently, in areas characterised by major secondary particulate emissions, PM2.5 monitoring should detect anthropogenic particulate pollutants without crustal particulate interference, whereas PM10 measurements should be used in areas with major primary anthropogenic particulate emissions.
Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers
NASA Technical Reports Server (NTRS)
Montgomery, L. D.; Williams, B. A.
1976-01-01
Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.
A. Bytnerowicz; W. Fraczek; S. Schilling; D. Alexander
2010-01-01
Monthly average ambient concentrations of gaseous nitric acid (HNO3) and ammonia (NH3) were monitored at the Athabasca Oils Sands Region (AOSR), Alberta, Canada, between May 2005 and September 2008. Generally, concentrations of both pollutants were elevated and highly variable in space and time. The highest atmospheric...
Method Development and Monitoring of Cyanotoxins in Water ...
This presentation describes method development of two ambient water LC/MS/MS methods for microcystins, cylindrospermopsin and anatoxin-a. Ruggedness of the methods will be demonstrated by evaluation of quality control samples derived from various water bodies across the country. Presentation at the Central Regional meeting of the American Chemical Society ambient water methods development for cyanotoxins
Olaguer, Eduardo P; Erickson, Matthew H; Wijesinghe, Asanga; Neish, Bradley S
2016-02-01
A mobile laboratory equipped with a proton transfer reaction mass spectrometer (PTR-MS) operated in Galena Park, Texas, near the Houston Ship Channel during the Benzene and other Toxics Exposure Study (BEE-TEX). The mobile laboratory measured transient peaks of benzene of up to 37 ppbv in the afternoon and evening of February 19, 2015. Plume reconstruction and source attribution were performed using the four-dimensional (4D) variational data assimilation technique and a three-dimensional (3D) micro-scale forward and adjoint air quality model based on mobile PTR-MS data and nearby stationary wind measurements at the Galena Park Continuous Air Monitoring Station (CAMS). The results of inverse modeling indicate that significant pipeline emissions of benzene may at least partly explain the ambient concentration peaks observed in Galena Park during BEE-TEX. Total pipeline emissions of benzene inferred within the 16-km(2) model domain exceeded point source emissions by roughly a factor of 2 during the observational episode. Besides pipeline leaks, the model also inferred significant benzene emissions from marine, railcar, and tank truck loading/unloading facilities, consistent with the presence of a tanker and barges in the Kinder Morgan port terminal during the afternoon and evening of February 19. Total domain emissions of benzene exceeded corresponding 2011 National Emissions Inventory (NEI) estimates by a factor of 2-6. Port operations involving petrochemicals may significantly increase emissions of air toxics from the transfer and storage of materials. Pipeline leaks, in particular, can lead to sporadic emissions greater than in emission inventories, resulting in higher ambient concentrations than are sampled by the existing monitoring network. The use of updated methods for ambient monitoring and source attribution in real time should be encouraged as an alternative to expanding the conventional monitoring network.
Personal Cabin Pressure Monitor and Warning System
NASA Technical Reports Server (NTRS)
Zysko, Jan A. (Inventor)
2002-01-01
A cabin pressure altitude monitor and warning system provides a warning when a detected cabin pressure altitude has reached a predetermined level. The system is preferably embodied in a portable, pager-sized device that can be carried or worn by an individual. A microprocessor calculates the pressure altitude from signals generated by a calibrated pressure transducer and a temperature sensor that compensates for temperature variations in the signals generated by the pressure transducer. The microprocessor is programmed to generate a warning or alarm if a cabin pressure altitude exceeding a predetermined threshold is detected. Preferably, the microprocessor generates two different types of warning or alarm outputs, a first early warning or alert when a first pressure altitude is exceeded. and a second more serious alarm condition when either a second. higher pressure altitude is exceeded, or when the first pressure altitude has been exceeded for a predetermined period of time. Multiple types of alarm condition indicators are preferably provided, including visual, audible and tactile. The system is also preferably designed to detect gas concentrations and other ambient conditions, and thus incorporates other sensors, such as oxygen, relative humidity, carbon dioxide, carbon monoxide and ammonia sensors, to provide a more complete characterization and monitoring of the local environment.
Personal Cabin Pressure Monitor and Warning System
NASA Astrophysics Data System (ADS)
Zysko, Jan A.
2002-09-01
A cabin pressure altitude monitor and warning system provides a warning when a detected cabin pressure altitude has reached a predetermined level. The system is preferably embodied in a portable, pager-sized device that can be carried or worn by an individual. A microprocessor calculates the pressure altitude from signals generated by a calibrated pressure transducer and a temperature sensor that compensates for temperature variations in the signals generated by the pressure transducer. The microprocessor is programmed to generate a warning or alarm if a cabin pressure altitude exceeding a predetermined threshold is detected. Preferably, the microprocessor generates two different types of warning or alarm outputs, a first early warning or alert when a first pressure altitude is exceeded. and a second more serious alarm condition when either a second. higher pressure altitude is exceeded, or when the first pressure altitude has been exceeded for a predetermined period of time. Multiple types of alarm condition indicators are preferably provided, including visual, audible and tactile. The system is also preferably designed to detect gas concentrations and other ambient conditions, and thus incorporates other sensors, such as oxygen, relative humidity, carbon dioxide, carbon monoxide and ammonia sensors, to provide a more complete characterization and monitoring of the local environment.
NASA Astrophysics Data System (ADS)
Sklaveniti, S.; Locoge, N.; Dusanter, S.; Leonardis, T.; Lew, M.; Bottorff, B.; Sigler, P. S. R.; Stevens, P. S.; Wood, E. C. D.; Kundu, S.; Gentner, D. R.
2015-12-01
Ozone is a greenhouse gas and a primary constituent of urban smog, irritating the respiratory system and damaging the vegetation. The current understanding of ozone chemistry in the troposphere indicates that net ozone production P(O3) occurs when peroxy radicals (HO2+RO2) react with NO producing NO2, whose photolysis leads to O3 formation. P(O3) values can be calculated from peroxy radical concentrations, either from ambient measurements or box model outputs. These two estimation methods often disagree for NOx mixing ratios higher than a few ppb, questioning our ability to measure peroxy radicals under high NOx conditions or indicating that there are still unknowns in our understanding of the radical and ozone production chemistry. Direct measurements of ozone production rates will help to address this issue and improve air quality regulations. We will present the development of an instrument for direct measurements of ozone production rates (OPR). The OPR instrument consists of three parts: (i) two quartz flow tubes sampling ambient air ("Ambient" and "Reference" flow tube), (ii) an O3-to-NO2 conversion unit, and (iii) a Cavity Attenuated Phase Shift (CAPS) monitor to measure NO2. The air in the Ambient flow tube undergoes the same photochemistry as in ambient air, while the Reference flow tube is covered by a UV filter limiting the formation of ozone. Exiting the flow tubes, ozone is converted into NO2 and the sum O3+NO2 (Ox) is measured by the CAPS monitor. The difference in Ox between the two flow tubes divided by the residence time yields the Ox production rate, P(Ox). P(O3) is assumed to be equal to P(Ox) when NO2 is efficiently photolyzed during daytime. We will present preliminary results from the Indiana Radical, Reactivity and Ozone Production Intercomparison (IRRONIC) campaign in Bloomington, Indiana, during July 2015, where ozone production rates were measured by introducing various amounts of NO inside the flow tubes to investigate the ozone production sensitivity.
Link-quality measurement and reporting in wireless sensor networks.
Chehri, Abdellah; Jeon, Gwanggil; Choi, Byoungjo
2013-03-04
Wireless Sensor networks (WSNs) are created by small hardware devices that possess the necessary functionalities to measure and exchange a variety of environmental data in their deployment setting. In this paper, we discuss the experiments in deploying a testbed as a first step towards creating a fully functional heterogeneous wireless network-based underground monitoring system. The system is mainly composed of mobile and static ZigBee nodes, which are deployed on the underground mine galleries for measuring ambient temperature. In addition, we describe the measured results of link characteristics such as received signal strength, latency and throughput for different scenarios.
Link-Quality Measurement and Reporting in Wireless Sensor Networks
Chehri, Abdellah; Jeon, Gwanggil; Choi, Byoungjo
2013-01-01
Wireless Sensor networks (WSNs) are created by small hardware devices that possess the necessary functionalities to measure and exchange a variety of environmental data in their deployment setting. In this paper, we discuss the experiments in deploying a testbed as a first step towards creating a fully functional heterogeneous wireless network-based underground monitoring system. The system is mainly composed of mobile and static ZigBee nodes, which are deployed on the underground mine galleries for measuring ambient temperature. In addition, we describe the measured results of link characteristics such as received signal strength, latency and throughput for different scenarios. PMID:23459389
NASA Technical Reports Server (NTRS)
Stackhouse, Paul W., Jr.; Charles, Robert W.; Chandler, William S.; Hoell, James M.; Westberg, David; Zhang, Taiping; Ziegler, Urban; Leng, Gregory J.; Meloche, Nathalie; Bourque, Kevin
2012-01-01
This paper describes building energy system production and usage monitoring using examples from the new RETScreen Performance Analysis Module, called RETScreen Plus. The module uses daily meteorological (i.e., temperature, humidity, wind and solar, etc.) over a period of time to derive a building system function that is used to monitor building performance. The new module can also be used to target building systems with enhanced technologies. If daily ambient meteorological and solar information are not available, these are obtained over the internet from NASA's near-term data products that provide global meteorological and solar information within 3-6 days of real-time. The accuracy of the NASA data are shown to be excellent for this purpose enabling RETScreen Plus to easily detect changes in the system function and efficiency. This is shown by several examples, one of which is a new building at the NASA Langley Research Center that uses solar panels to provide electrical energy for building energy and excess energy for other uses. The system shows steady performance within the uncertainties of the input data. The other example involves assessing the reduction in energy usage by an apartment building in Sweden before and after an energy efficiency upgrade. In this case, savings up to 16% are shown.
Sather, Mark E; Cavender, Kevin
2016-07-13
In the last 30 years ambient ozone concentrations have notably decreased in the South Central U.S. Yet, current ambient ozone concentrations measured over the past three years 2013-2015 in this area of the U.S. are not meeting the U.S. 2015 8 hour ozone standard of 70 parts per billion (ppb). This paper provides an update on long-term trends analyses of ambient 8 hour ozone and ozone precursor monitoring data collected over the past 30 years (1986-2015) in four South Central U.S. cities, following up on two previously published reviews of 20 and 25 year trends for these cities. All four cities have benefitted from national ozone precursor controls put in place during the 1990s and 2000s involving cleaner vehicles (vehicle fleet turnover/replacement over time), cleaner fuels, cleaner gasoline and diesel engines, and improved inspection/maintenance programs for existing vehicles. Additional ozone precursor emission controls specific to each city are detailed in this paper. The controls have resulted in impressive ambient ozone and ambient ozone precursor concentration reductions in the four South Central U.S. cities over the past 30 years, including 31-70% ambient nitrogen oxides (NOx) concentration declines from historical peaks to the present, 43-72% volatile organic compound (VOC) concentration declines from historical peaks to the present, a related 45-76% VOC reactivity decline for a subset of VOC species from historical peaks to the present, and an 18-38 ppb reduction in city 8 hour ozone design value concentrations. A new challenge for each of the four South Central U.S. cities will be meeting the U.S. 2015 8 hour ozone standard of 70 ppb.
Monitoring Initiative Grants under Section 106 of the Clean Water Act
Each year, EPA provides funding to states, eligible interstate agencies, and eligible tribes to support ambient water quality monitoring programs and implement a multi-year survey of the condition of nation’s waters to track changes over time.
CURRENT STATUS OF THE EPA PROTOCOL GAS PROGRAM
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. EPA has published a protocol to establish the traceability of these standards to national refer...
Current Status of EPA Verification Program for EPA Protocol Gases
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...
EPA Protocol Gas Verification Program - Presented at NIST Gas Panel Meeting
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...
Liu, Ning; Lu, Xin; Yang, YuHan; Yao, Chen Xi; Ning, BaoMing; He, Dacheng; He, Lan; Ouyang, Jin
2015-10-01
A new approach for monitoring the binding affinity between drugs and alpha 1-acid glycoprotein in real time was developed based on a combination of drug-protein reaction followed by Venturi easy ambient sonic-spray ionization mass spectrometry determination of the free drug concentrations. A known basic drug, propranolol was used to validate the new built method. Binding constant values calculated by venturi easy ambient sonic-spray ionization mass spectrometry was in good accordance with a traditional ultrafiltration combined with high performance liquid chromatography method. Then six types of basic drugs were used as the samples to conduct the real time analysis. Upon injection of alpha 1-acid glycoprotein to the drug mixture, the ion chromatograms were extracted to show the changes in the free drug concentrations in real time. By observing the drop-out of six types of drugs during the whole binding reaction, the binding affinities of different drugs were distinguished. A volume shift validating experiment and an injection delay correcting experiment were also performed to eliminate extraneous factors and verify the reliability of our experiment. Therefore, the features of Venturi easy ambient sonic-spray ionization mass spectrometry (V-EASI-MS) and the experimental results indicate that our technique is likely to become a powerful tool for monitoring drug-AGP binding affinity in real time. Copyright © 2015 Elsevier B.V. All rights reserved.
Guo, Yu-Ming; Wang, Jia-Jia; Li, Guo-Xing; Zheng, Ya-An; He, Wichmann; Pan, Xiao-Chuan
2009-08-01
To explore the association between ambient average temperature and hospital emergency room visits for cardiovascular diseases (International Classification of Diseases, Tenth Vision ICD-10: I00 - I99) in Beijing, China. Data was collected on daily hospital emergency room visits for cardiovascular diseases from Peking University Third Hospital, including meteorological data (daily average temperature, relative humidity, wind speed, and atmospheric pressure) from the China Meteorological Data Sharing Service System, and on air pollution from the Beijing Municipal Environmental Monitoring Center. Time-stratified case-crossover design was used to analyze data on 4 seasons. After adjusting data on air pollution, 1 degree ( degrees C) increase of ambient average temperature would associate with the emergency room visits of odds ratio (ORs) as 1.282 (95%CI: 1.250 - 1.315), 1.027 (95%CI: 1.001 - 1.055), 0.661 (95%CI: 0.637 - 0.687), and 0.960 (95%CI: 0.937 - 0.984) in spring, summer, autumn, and winter respectively. After controlling the influence of relative humidity, wind speed, and atmospheric pressure, 1 degrees C increase in the ambient average temperature would be associated with the emergency room visits on ORs value as 1.423 (95%CI: 1.377 - 1.471), 1.082 (95%CI: 1.041 - 1.124), 0.633 (95%CI: 0.607 - 0.660) and 0.971 (95%CI: 0.944 - 1.000) in spring, summer, autumn, and winter respectively. These data on outcomes suggested that the elevated level of ambient temperature would increase the hospital emergency room visits for cardiovascular diseases in spring and summer while the elevated level of ambient temperature would decrease the hospital emergency room visits for the cardiovascular diseases in autumn and winter, suggesting that patients with cardiovascular diseases should pay attention to the climate change.
Turbine airfoil with ambient cooling system
Campbell, Jr, Christian X.; Marra, John J.; Marsh, Jan H.
2016-06-07
A turbine airfoil usable in a turbine engine and having at least one ambient air cooling system is disclosed. At least a portion of the cooling system may include one or more cooling channels configured to receive ambient air at about atmospheric pressure. The ambient air cooling system may have a tip static pressure to ambient pressure ratio of at least 0.5, and in at least one embodiment, may include a tip static pressure to ambient pressure ratio of between about 0.5 and about 3.0. The cooling system may also be configured such that an under root slot chamber in the root is large to minimize supply air velocity. One or more cooling channels of the ambient air cooling system may terminate at an outlet at the tip such that the outlet is aligned with inner surfaces forming the at least one cooling channel in the airfoil to facilitate high mass flow.
2016-01-01
We developed a technique to monitor spatially confined surface reactions with mass spectrometry under ambient conditions, without the need for voltage or organic solvents. Fused-silica capillaries immersed in an aqueous solution, positioned in close proximity to each other and the functionalized surface, created a laminar flow junction with a resulting reaction volume of ∼5 pL. The setup was operated with a syringe pump, delivering reagents to the surface through a fused-silica capillary. The other fused-silica capillary was connected to a Venturi easy ambient sonic-spray ionization source, sampling the resulting analytes at a slightly higher flow rate compared to the feeding capillary. The combined effects of the inflow and outflow maintains a chemical microenvironment, where the rate of advective transport overcomes diffusion. We show proof-of-concept where acetylcholinesterase was immobilized on an organosiloxane polymer through electrostatic interactions. The hydrolysis of acetylcholine by acetylcholinesterase into choline was monitored in real-time for a range of acetylcholine concentrations, fused-silica capillary geometries, and operating flow rates. Higher reaction rates and conversion yields were observed with increasing acetylcholine concentrations, as would be expected. PMID:27249533
Remote monitoring of parental incubation conditions in the greater sandhill crane
Gee, G.F.; Hatfield, J.; Howey, P.J.
1995-01-01
To monitor incubation conditions in nests of greater sandhill cranes, a radiotransmitting egg was built using six temperature sensors, a position sensor, and a light sensor. Sensor readings were received, along with time of observations, and stored in a computer. The egg was used to monitor incubation in nests of six pairs of cranes during 1987 and 1988. Ambient temperature was also measured. Analysis of covariance (ANCOVA) was used to relate highest egg temperature, core egg temperature, and lowest egg temperature to ambient temperature, time since the egg was last turned, and time since the beginning of incubation. Ambient temperature had the greatest effect on egg temperature (P 0.0001), followed by the time since the beginning of incubation and time since the egg was last turned. Pair effect, the class variable in the ANCOVA. was also very significant (P < 0.0001). A nine-term Fourier series was used to estimate the average core egg temperature versus time of day and was found to fit the data well (r2 = 0.94). The Fourier series will be used to run a mechanical incubator to simulate natural incubation conditions for cranes.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-11
... requirement, monitoring sites ID 42-003-0093 (North Park) and ID 42- 003-0095 (Moon) have missing data for the... monitoring periods 2007-2009 and 2008-2010, EPA has addressed the missing data by applying a recently... based upon complete, quality-assured and certified ambient air monitoring data for the 2008-2010 period...
U.S. EPA response to the Fukushima Daiichi Nuclear Power Plant accident.
Tupin, Edward A; Boyd, Michael A; Mosser, Jennifer E; Wieder, Jessica S
2012-05-01
During the spring of 2011, the U.S. Environmental Protection Agency (EPA) used its national radiation monitoring and sampling system, RadNet, to detect, identify, and inform the public about radioactive material in the United States resulting from Japan's Fukushima Daiichi Nuclear Power Plant release. The RadNet system monitors ambient air, drinking water, precipitation, and pasteurized milk for radionuclides. To supplement its existing stationary (fixed) continuous air monitoring system, EPA deployed additional air monitors to Saipan, Guam, and locations in the western United States. The Agency also accelerated the regular quarterly sampling of milk and drinking water and collected an additional round of samples. For two months, staff located at EPA's Headquarters Emergency Operations Center, west coast regional offices, and National Air and Radiation Environmental Lab worked seven days a week to handle the increased radiochemical sample analysis from air filters, precipitation, drinking water, and milk; provide interagency scientific input; and answer press and public inquiries. EPA's data was consistent with what was expected from the Fukushima Daiichi Nuclear Power Plant release. The levels of radioactivity were so low that the readings from the near-real-time RadNet air monitors stayed within normal background ranges. Detailed sample analyses were needed to identify the radionuclides associated with the release. Starting at the end of April and continuing through May 2011, levels of radioactive material decreased as expected.
Shortcomings of low-cost imaging systems for viewing computed radiographs.
Ricke, J; Hänninen, E L; Zielinski, C; Amthauer, H; Stroszczynski, C; Liebig, T; Wolf, M; Hosten, N
2000-01-01
To assess potential advantages of a new PC-based viewing tool featuring image post-processing for viewing computed radiographs on low-cost hardware (PC) with a common display card and color monitor, and to evaluate the effect of using color versus monochrome monitors. Computed radiographs of a statistical phantom were viewed on a PC, with and without post-processing (spatial frequency and contrast processing), employing a monochrome or a color monitor. Findings were compared with the viewing on a radiological Workstation and evaluated with ROC analysis. Image post-processing improved the perception of low-contrast details significantly irrespective of the monitor used. No significant difference in perception was observed between monochrome and color monitors. The review at the radiological Workstation was superior to the review done using the PC with image processing. Lower quality hardware (graphic card and monitor) used in low cost PCs negatively affects perception of low-contrast details in computed radiographs. In this situation, it is highly recommended to use spatial frequency and contrast processing. No significant quality gain has been observed for the high-end monochrome monitor compared to the color display. However, the color monitor was affected stronger by high ambient illumination.
2014-10-01
a period of time by electrodes attached to the surface of the skin, are used in almost every clinical environment. Pulse oximeters , which measure the...medical devices, for example, pulse oximeters , vascular diagnostics, and digital beat-to-beat blood pressure measurement systems (Allen 2007). PPG is...principle is pulse oximetry. 1.2 Pulse Oximetry A pulse oximeter monitors the blood-oxygen saturation level and pulse rate in the human blood by using
1992-12-01
engineering support for completed studies--namely, the wetlands, slime mold , and bird species and communities studies performed in Wisconsin-appears in previous...3 4. ENGINEERING SUPPORT ACTIVITIES 4.1 Soil Amoeba Growth Chambers 4.1.1 Background 3 The soil amoeba and now-completed slime mold studies both...cultures of soil amoeba and slime mold to the earth’s ambient temperature. It is also desirable to expose the cultures to the same EM environment that they
Biofouling and the continuous monitoring of underwater light from a seagrass perspective
Onuf, C.P.
2006-01-01
For more than a decade, inexpensive electronic instruments have made continuous underwater light monitoring an integral part of many seagrass studies. Although biofouling, if not controlled, compromises the utility of the record. A year-long assessment of the time course of sensor fouling, in the Laguna Madre of Texas established that light transmitted through the fouling layer after 2 wk of exposure exceeded 90% except for a 6-8 wk period in May and June. On that basis, a 2-wk interval was chosen for routine servicing. Subsequent monitoring proved this choice to be grossly in error. The period of sub-90% transmittance after 2 wk extended to 4-6 mo annually over the next 3 yr. Fouling was strongly correlated with temperature, ambient light, and year. Since an algal bloom of 7-yr duration finally waned during this study, increased ambient light seemed most likely to explain increased fouling later in the study. The explanatory value of light was less than temperature or year in multiple regression, requiring some other explanation of the date effect than change in ambient light. Allelopathic and suspension-feeding depressant effects of the brown tide are offered as the most likely cause of unusually low fouling in the first year. Biofouling was so unpredictable and rapid in this study that at least weekly maintenance would be required to assure reliability of the light monitoring record. ?? 2006 Estuarine Research Federation.
Influence of room lighting on grey-scale perception with a CRT-and a TFT monitor display.
Haak, R; Wicht, M J; Hellmich, M; Nowak, G; Noack, M J
2002-05-01
To determine the influence of ambient lighting on grey-scale perception using a cathode-ray tube (CRT) and a thin film transistor (TFT) computer display. A cathode ray tube (Nokia XS 446) and a liquid crystal display (Panasonic LC 50S) were used at reduced room lighting (70 lux) and under conditions recommended for a dental operatory (1000 lux). Twenty-seven observers examined twice a modified SMPTE test pattern [0 to 255; 255 to 0] grey-scale values. The corresponding contrast differences were allocated to four ranges of grey levels (I: 0-63; II: 64-127; III: 128-191; IV: 192-255). The influences of monitor type, grey-scale range and illumination were evaluated by means of repeated measures analysis of variance. Detection of differences in monochromatic intensity was significantly earlier with reduced lighting (P<0.0001). When full ambient lighting was used, the TFT display was superior compared to the CRT monitor in ranges II and III (P<0.0001), whereas no differences could be detected for grey intensities between 0 and 63 (P=0.71) and between 192 and 255 (P=0.36). Background lighting hampers grey-scale perception on computer displays. In this study of one TFT and one CRT monitor, the TFT in full ambient lighting was associated with earlier detection of grey scale differences than CRT.
An autonomous structural health monitoring solution
NASA Astrophysics Data System (ADS)
Featherston, Carol A.; Holford, Karen M.; Pullin, Rhys; Lees, Jonathan; Eaton, Mark; Pearson, Matthew
2013-05-01
Combining advanced sensor technologies, with optimised data acquisition and diagnostic and prognostic capability, structural health monitoring (SHM) systems provide real-time assessment of the integrity of bridges, buildings, aircraft, wind turbines, oil pipelines and ships, leading to improved safety and reliability and reduced inspection and maintenance costs. The implementation of power harvesting, using energy scavenged from ambient sources such as thermal gradients and sources of vibration in conjunction with wireless transmission enables truly autonomous systems, reducing the need for batteries and associated maintenance in often inaccessible locations, alongside bulky and expensive wiring looms. The design and implementation of such a system however presents numerous challenges. A suitable energy source or multiple sources capable of meeting the power requirements of the system, over the entire monitoring period, in a location close to the sensor must be identified. Efficient power management techniques must be used to condition the power and deliver it, as required, to enable appropriate measurements to be taken. Energy storage may be necessary, to match a continuously changing supply and demand for a range of different monitoring states including sleep, record and transmit. An appropriate monitoring technique, capable of detecting, locating and characterising damage and delivering reliable information, whilst minimising power consumption, must be selected. Finally a wireless protocol capable of transmitting the levels of information generated at the rate needed in the required operating environment must be chosen. This paper considers solutions to some of these challenges, and in particular examines SHM in the context of the aircraft environment.
Comparison of stationary and personal air sampling with an ...
Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency’s Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and −0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort. The purpose of the study was to investigate the use of air-dispersion modeling as an approach to exposure assessment for ambient manganese.
Web-Based Real-Time Emergency Monitoring
NASA Technical Reports Server (NTRS)
Harvey, Craig A.; Lawhead, Joel
2007-01-01
The Web-based Real-Time Asset Monitoring (RAM) module for emergency operations and facility management enables emergency personnel in federal agencies and local and state governments to monitor and analyze data in the event of a natural disaster or other crisis that threatens a large number of people and property. The software can manage many disparate sources of data within a facility, city, or county. It was developed on industry-standard Geo- Spatial software and is compliant with open GIS standards. RAM View can function as a standalone system, or as an integrated plugin module to Emergency Operations Center (EOC) software suites such as REACT (Real-time Emergency Action Coordination Tool), thus ensuring the widest possible distribution among potential users. RAM has the ability to monitor various data sources, including streaming data. Many disparate systems are included in the initial suite of supported hardware systems, such as mobile GPS units, ambient measurements of temperature, moisture and chemical agents, flow meters, air quality, asset location, and meteorological conditions. RAM View displays real-time data streams such as gauge heights from the U.S. Geological Survey gauging stations, flood crests from the National Weather Service, and meteorological data from numerous sources. Data points are clearly visible on the map interface, and attributes as specified in the user requirements can be viewed and queried.
Final Regulatory Impact Analysis (RIA) for the NO2 National Ambient Air Quality Standards (NAAQS)
This RIA provides illustrative estimates, as of January 2010, of the incremental costs and monetized human health benefits of attaining the revised NO2 NAAQS within the the existing community-wide monitoring network of 409 monitors.
Overview of Emerging Air Sensors
These slides will be presented at the 2014 National Ambient Air Monitoring Conference in Atlanta, GA during August 11-15, 2014. The goal is to provide an overview of air sensor technology and the audience will be primarily state air monitoring agencies and EPA Regions.
NASA Astrophysics Data System (ADS)
Fores, B.; Champollion, C.; Mainsant, G.; Fort, A.; Albaric, J.
2016-12-01
Karstic hydrosystems represent one of the main water resources in the Mediterranean area but are challenging for geophysical methods. The GEK (Geodesy in Karstic Environment) observatory has been setup in 2011 to study the unsaturated zone of a karstic system in the south of France. The unsaturated zone (the epikarst) is thick and up to 100m on the site. Since 2011, gravity, rainfall and evapotranspiration are monitored. Together, they allow precise estimation of the global water storage changes but lack depth resolution. Surface waves velocity variations, obtained from ambient seismic noise monitoring are used here to overcome this lack. Indeed, velocities depend on saturation and the depths where changes occur can be defined as surface waves are dispersive. From October 2014 to November 2015, two seismometers have been recording noise. Velocity changes at a narrow frequency band (6-8 Hz) have shown a clear annual cycle. Minimum velocity is several months late on precipitations, which is coherent with a slow infiltration and a maximum sensitivity at -40m for these frequencies and this site. Models have been made with the Hydrus-1D software which allows modeling 1D-flow in variably saturated media. With a stochastic sampling, we have researched the underground parameters that reproduce the most the different observations (gravity, evapotranspiration and rainfall, and velocity changes). We show that velocity changes clearly constrain the hydraulic conductivity of the medium. Ambient seismic noise is therefore a promising method to study unsaturated zone which are too deep or too heterogeneous for classic methods.
Monitoring steel bridge renovation using lead isotopic tracing.
Salome, Fred; Gulson, Brian; Chiaradia, Massimo; Davis, Jeffrey; Morris, Howard
2017-05-01
Monitoring removal of lead (Pb) paint from steel structures usually involves analysis of environmental samples for total lead and determination of blood Pb levels of employees involved in the Pb paint removal. We used high precision Pb isotopic tracing for a bridge undergoing Pb paint removal to determine if Pb in the environmental and blood samples originated from the bridge paint. The paint system on the bridge consisted of an anti-corrosive red Pb primer top-coated with a Micaceous Iron Oxide (MIO) alkyd. Analysis of the red Pb primer gave uniform isotopic ratios indicative of Pb from the geologically-ancient Broken Hill mines in western New South Wales, Australia. Likewise waste abrasive material, as anticipated, had the same isotopic composition as the paint. The isotopic ratios for other samples lay on 2 separate linear arrays on a 207 Pb/ 204 Pb versus 206 Pb/ 204 Pb diagram, one largely defined by gasoline and the majority of the ambient air data, and the other by data for one sample each of gasoline and ambient air and underwater sediments. Isotopic ratios in background ambient air samples for the project were characteristic of leaded gasoline. Air sampling during paint removal showed a contribution of paint Pb ranging from about 20 to 40%. Isotopic ratios in the blood of 8 employees prior to the commencement of work showed that 6 of these had been previously exposed to the Broken Hill Pb possibly from earlier bridge paint removal projects. One subject appeared to have increased exposure to Pb probably from the paint renovations. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Martin, E. R.; Dou, S.; Lindsey, N.; Chang, J. P.; Biondi, B. C.; Ajo Franklin, J. B.; Wagner, A. M.; Bjella, K.; Daley, T. M.; Freifeld, B. M.; Robertson, M.; Ulrich, C.; Williams, E. F.
2016-12-01
Localized strong sources of noise in an array have been shown to cause artifacts in Green's function estimates obtained via cross-correlation. Their effect is often reduced through the use of cross-coherence. Beyond independent localized sources, temporally or spatially correlated sources of noise frequently occur in practice but violate basic assumptions of much of the theory behind ambient noise Green's function retrieval. These correlated noise sources can occur in urban environments due to transportation infrastructure, or in areas around industrial operations like pumps running at CO2 sequestration sites or oil and gas drilling sites. Better understanding of these artifacts should help us develop and justify methods for their automatic removal from Green's function estimates. We derive expected artifacts in cross-correlations from several distributions of correlated noise sources including point sources that are exact time-lagged repeats of each other and Gaussian-distributed in space and time with covariance that exponentially decays. Assuming the noise distribution stays stationary over time, the artifacts become more coherent as more ambient noise is included in the Green's function estimates. We support our results with simple computational models. We observed these artifacts in Green's function estimates from a 2015 ambient noise study in Fairbanks, AK where a trenched distributed acoustic sensing (DAS) array was deployed to collect ambient noise alongside a road with the goal of developing a permafrost thaw monitoring system. We found that joints in the road repeatedly being hit by cars travelling at roughly the speed limit led to artifacts similar to those expected when several points are time-lagged copies of each other. We also show test results of attenuating the effects of these sources during time-lapse monitoring of an active thaw test in the same location with noise detected by a 2D trenched DAS array.
A Modular IoT Platform for Real-Time Indoor Air Quality Monitoring.
Benammar, Mohieddine; Abdaoui, Abderrazak; Ahmad, Sabbir H M; Touati, Farid; Kadri, Abdullah
2018-02-14
The impact of air quality on health and on life comfort is well established. In many societies, vulnerable elderly and young populations spend most of their time indoors. Therefore, indoor air quality monitoring (IAQM) is of great importance to human health. Engineers and researchers are increasingly focusing their efforts on the design of real-time IAQM systems using wireless sensor networks. This paper presents an end-to-end IAQM system enabling measurement of CO₂, CO, SO₂, NO₂, O₃, Cl₂, ambient temperature, and relative humidity. In IAQM systems, remote users usually use a local gateway to connect wireless sensor nodes in a given monitoring site to the external world for ubiquitous access of data. In this work, the role of the gateway in processing collected air quality data and its reliable dissemination to end-users through a web-server is emphasized. A mechanism for the backup and the restoration of the collected data in the case of Internet outage is presented. The system is adapted to an open-source Internet-of-Things (IoT) web-server platform, called Emoncms, for live monitoring and long-term storage of the collected IAQM data. A modular IAQM architecture is adopted, which results in a smart scalable system that allows seamless integration of various sensing technologies, wireless sensor networks (WSNs) and smart mobile standards. The paper gives full hardware and software details of the proposed solution. Sample IAQM results collected in various locations are also presented to demonstrate the abilities of the system.
Ambient Noise Monitoring of the Santa Clara and San Gabriel Aquifers
NASA Astrophysics Data System (ADS)
Clements, T.; Denolle, M.
2016-12-01
Ambient noise cross-correlation is an effective technique to monitor temporal changes in the properties of the solid earth. The technique has had particular success in monitoring over time scales differing by orders of magnitude, with precursors to volcanic eruptions occurring over days [Brenguier, et al., 2008, Nature] and post-seismic relaxation in fault zones occurring over years [Brenguier, et al., 2008, Science]. Recently, the technique was extended to investigate the interaction of the solid earth and climate via ice sheet melt [Mordret et al.,2016]. In that vein, we use ambient noise cross-correlation to monitor basin-scale aquifers. The technique is amenable to studying aquifers, as it has potential for high spatial resolution, on the scale of a basin and can monitor aquifer recharge/draw down on timescales from large, single-day storms to multi-year droughts. Geodetics studies have previously recorded both long term, in the Santa Clara Valley [Chaussard et al., 2014, Schmidt and Burgmann, 2003], and short-term, in the San Gabriel Valley [King et al. 2007], ground uplift due to aquifer recharge. We use the Moving Window Cross Spectral technique [Clarke et al., 2011] to monitor wave-speed perturbation in the Santa Clara valley over the period 2001-2016 and San Gabriel Basin over the period 1995-2016. Preliminary results, using stations from the Berkeley Digital Seismograph Network and the USGS Northern California Regional Network, show that seismic velocities vary 0.1% intra-annually. We explore the temporal variations, along with correlations in observed ground water data, precipitation and geodesic measurements to deduce the poroelastic properties of the aquifers during the last two El-Nino and recent droughts in California.
Baeza, A; Corbacho, J A; Caballero, J M; Ontalba, M A; Vasco, J; Valencia, D
2017-09-25
Automatic real-time warning networks are essential for the almost immediate detection of anomalous levels of radioactivity in the environment. In the case of Extremadura region (SW Spain), a radiological network (RARE) has been operational in the vicinity of the Almaraz nuclear power plant and in other areas farther away since 1992. There are ten air monitoring stations equipped with Geiger-Müller counters in order to evaluate the external ambient gamma dose rate. Four of these stations have a commercial system that provides estimates of the total artificial alpha and beta activity concentrations in aerosols, and of the 131 I activity (gaseous fraction). Despite experience having demonstrated the benefits and robustness of these commercial systems, important improvements have been made to one of these air monitoring systems. In this paper, the analytical and maintenance shortcomings of the original commercial air monitoring system are described first; the new custom-designed advanced air monitoring system is then presented. This system is based mainly on the incorporation of gamma spectrometry using two scintillation detectors, one of NaI:Tl and the other of LaBr 3 :Ce, and compact multichannel analysers. Next, a comparison made of the results provided by the two systems operating simultaneously at the same location for three months shows the advantages of the new advanced air monitoring system. As a result, the gamma spectrometry analysis allows passing from global alpha and beta activity determinations due to artificial radionuclides in aerosols, and the inaccurate measurement of the gaseous 131 I activity concentration, to the possibility of identifying a large number of radionuclides and quantifying each of their activity concentrations. Moreover, the new station's dual capacity is designed to work in early warning monitoring mode and surveillance monitoring mode. This is based on custom developed software that includes an intelligent system to issue the necessary warnings when radiological anomalies or technical problems are identified. Implicitly, for the construction of the advanced station, substantial mechanical and electronic developments have been required. They have essentially consisted of integrating a new replacement device, whose operation has reduced the maintenance tasks.
Airplane takeoff and landing performance monitoring system
NASA Technical Reports Server (NTRS)
Middleton, David B. (Inventor); Srivatsan, Raghavachari (Inventor); Person, Jr., Lee H. (Inventor)
1991-01-01
The invention is a real-time takeoff and landing performance monitoring system for an aircraft which provides a pilot with graphic and metric information to assist in decisions related to achieving rotation speed (V.sub.R) within the safe zone of a runway, or stopping the aircraft on the runway after landing or take-off abort. The system processes information in two segments: a pretakeoff segment and a real-time segment. One-time inputs of ambient conditions and airplane configuration information are used in the pretakeoff segment to generate scheduled performance data. The real-time segment uses the scheduled performance data, runway length data and transducer measured parameters to monitor the performance of the airplane throughout the takeoff roll. Airplane and engine performance deficiencies are detected and annunciated. A novel and important feature of this segment is that it updates the estimated runway rolling friction coefficient. Airplane performance predictions also reflect changes in head wind occurring as the takeoff roll progresses. The system provides a head-down display and a head-up display. The head-up display is projected onto a partially reflective transparent surface through which the pilot views the runway. By comparing the present performance of the airplane with a predicted nominal performance based upon given conditions, performance deficiencies are detected by the system.
Na, Na; Shi, Ruixia; Long, Zi; Lu, Xin; Jiang, Fubin; Ouyang, Jin
2014-10-01
In this study, the real-time analysis of self-assembled nucleobases was employed by Venturi easy ambient sonic-spray ionization mass spectrometry (V-EASI-MS). With the analysis of three nucleobases including 6-methyluracil (6MU), uracil (U) and thymine (T) as examples, different orders of clusters centered with different metal ions were recorded in both positive and negative modes. Compared with the results obtained by traditional electrospray ionization mass spectrometry (ESI-MS) under the same condition, more clusters with high orders, such as [6MU7+Na](+), [6MU15+2NH4](2+), [6MU10+Na](+), [T7+Na](+), and [T15+2NH4](2+) were detected by V-EASI-MS, which demonstrated the soft ionization ability of V-EASI for studying the non-covalent interaction in a self-assembly process. Furthermore, with the injection of K(+) to the system by a syringe pumping, the real-time monitoring of the formation of nucleobases clusters was achieved by the direct extraction of samples from the system under the Venturi effect. Therefore, the effect of cations on the formation of clusters during self-assembly of nucleobases was demonstrated, which was in accordance with the reports. Free of high voltage, heating or radiation during the ionization, this technique is much soft and suitable for obtaining the real-time information of the self-assembly system, which also makes it quite convenient for extraction samples from the reaction system. This "easy and soft" ionization technique has provided a potential pathway for monitoring and controlling the self-assembly processes. Copyright © 2014 Elsevier B.V. All rights reserved.
Air pollution effects field research facility: 3. UV-B exposure and monitoring system
DOE Office of Scientific and Technical Information (OSTI.GOV)
McEvers, J.A.; Hileman, M.S.; Edwards, N.T.
1993-03-01
The Oak Ridge National Laboratory Outdoor UltraViolet-B (UV-B) Exposure and Monitoring Facility was developed in 1980 to provide well-controlled and -monitored exposure of specific terrestrial plant. species to elevated levels of ultraviolet (UV) radiation. The introduction of various anthropogenic agents into the earth`s stratosphere has resulted in a decrease in the volume of ozone (O{sub 3}) present here. The decrease in O{sub 3} has resulted in an increase in the level of UV radiation reaching thee earth`s surface. Of particular interest is the level of UV-B, because it has the most detrimental effect on living tissue. A thorough understanding ofmore » the effects of elevated levels of UV-B on living tissue is critical to the formulation of economic policy regarding production of such agents and alternative strategies. The UV region of interest is referred to as UV-B and corresponds to radiation with a wavelength of 290 to 320 nm. Design, operation, and performance of the automated generation, exposure, and monitoring system are described. The system has proved to be reliable and easy to maintain and operate, and it provides significant flexibility in exposure programs. The system software is described, and detailed listings are provided. The ability to expose plants to controlled set point percentages of UV-B above the ambient level was developed.« less
NASA Astrophysics Data System (ADS)
Vermeul, V.; McKinley, J. P.; Newcomer, D.; Fritz, B. G.; Mackley, R.; Zachara, J. M.
2010-12-01
Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. In this study, simultaneous measurement of 1) wellbore flow using an electromagnetic borehole flowmeter (EBF), 2) depth discrete hydraulic head, and 3) aqueous uranium concentrations were used to quantify wellbore flow and assess the associated impacts on measured aqueous concentrations. Monitoring results demonstrate the utility of continuous (i.e., hourly measurements for ~ one month) ambient wellbore flow monitoring and show that relatively large wellbore flows (up to 4 LPM) can be induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an EBF system allowed these effects to be evaluated in concert with continuously monitored river stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multi-level well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. In addition, observed variability in aqueous concentrations measured during active tracer transport experiments provided additional evidence of wellbore flow impacts and showed that the magnitude and direction of wellbore flow varied spatially across the wellfield. An approach to mitigate these effects based on increasing hydraulic resistance within the wellbore was evaluated. This research is part of the ERSP Hanford IFRC at Pacific Northwest National Laboratory.
Schwartze, Jonas; Prekazi, Arianit; Schrom, Harald; Marschollek, Michael
2017-01-01
Ambient assisted living (AAL) may support ageing in place but is primarily driven by technology. The aim of this work is, to identifying reasons to move into assisted living institutions, their range of service and possible substitutability. We did semi-structured interviews with five experts from assisted living institutions and used results to design and implement assistive technologies in an AAL environment using BASIS, a cross domain bus system for smart buildings. Reasons for moving to assisted living institutions are expected benefits for chronic health problems, safety, social isolation and carefree living. We implemented six application systems for inactivity monitoring, stove shutdown, air quality monitoring, medication and appointment reminders, detection of unwanted situations before leaving and optical ringing of the doorbell. Substitution of selected assisted living services is feasible and has potential to delay necessity to move into assisted living institution if complement social services are installed.
NASA Astrophysics Data System (ADS)
Zafrir, Hovav; Benhorin, Yochy; Malik, Uri; Chemo, Chaim
2016-04-01
An enhanced radon monitoring system was designed in order to study shallow versus deep subsurface processes affecting the appearance of radon anomalies. The method is based on the assumption that the climatic influence is limited since its energy decreases with the decrease in thickness of the geological cover whereby its effect is reduced to a negligible value at depth. Hence, lowering gamma and alpha detectors into deep boreholes and monitoring their temporal variations relative to a reference couple at shallow depths of 10-40 m eliminates the ambient thermal and pressure-induced contribution from the total radon time series. It allows highlighting the residual portion of the radon signals that might be associated with the geodynamic processes. The primary technological key is the higher sensitivity of the gamma detectors - in comparison to the solid-state alpha detectors, which are also suitable for threading into narrow boreholes in parallel to the narrow gamma detector (Zafrir et al., 2013*). The unique achievements of the novel system that was installed at the Sde Eliezer site close to the Hula Valley western border fault (HWBF) in northern Israel are: a) Determination, for the first time, of the radon movement velocity within rock layers at depths of several tens of meters, namely, 25 m per hour on average; b) Distinguishing between the diurnal periodical effect of the ambient temperature and the semi-diurnal effect of the ambient pressure on the radon temporal spectrum; c) Identification of a radon random pre-seismic anomaly preceding the Nuweiba, M 5.5 earthquake of 27 June 2015 that occurred within Dead Sea Fault Zone. * Zafrir, H., Barbosa, S.M. and Malik, U., 2013. Differentiation between the effect of temperature and pressure on radon within the subsurface geological media, Radiat. Meas., 49, 39-56. doi:10.1016/j.radmeas.2012.11.019.
Gas monitoring onboard ISS using FTIR spectroscopy
NASA Astrophysics Data System (ADS)
Gisi, Michael; Stettner, Armin; Seurig, Roland; Honne, Atle; Witt, Johannes; Rebeyre, Pierre
2017-06-01
In the confined, enclosed environment of a spacecraft, the air quality must be monitored continuously in order to safeguard the crew's health. For this reason, OHB builds the ANITA2 (Analysing Interferometer for Ambient Air) technology demonstrator for trace gas monitoring onboard the International Space Station (ISS). The measurement principle of ANITA2 is based on the Fourier Transform Infrared (FTIR) technology with dedicated gas analysis software from the Norwegian partner SINTEF. This combination proved to provide high sensitivity, accuracy and precision for parallel measurements of 33 trace gases simultaneously onboard ISS by the precursor instrument ANITA1. The paper gives a technical overview about the opto-mechanical components of ANITA2, such as the interferometer, the reference Laser, the infrared source and the gas cell design and a quick overview about the gas analysis. ANITA2 is very well suited for measuring gas concentrations specifically but not limited to usage onboard spacecraft, as no consumables are required and measurements are performed autonomously. ANITA2 is a programme under the contract of the European Space Agency, and the air quality monitoring system is a stepping stone into the future, as a precursor system for manned exploration missions.
NASA Astrophysics Data System (ADS)
Eason, Thomas J.; Bond, Leonard J.; Lozev, Mark G.
2016-02-01
The accuracy, precision, and reliability of ultrasonic thickness structural health monitoring systems are discussed in-cluding the influence of systematic and environmental factors. To quantify some of these factors, a compression wave ultrasonic thickness structural health monitoring experiment is conducted on a flat calibration block at ambient temperature with forty four thin-film sol-gel transducers and various time-of-flight thickness calculation methods. As an initial calibration, the voltage response signals from each sensor are used to determine the common material velocity as well as the signal offset unique to each calculation method. Next, the measurement precision of the thickness error of each method is determined with a proposed weighted censored relative maximum likelihood analysis technique incorporating the propagation of asymmetric measurement uncertainty. The results are presented as upper and lower confidence limits analogous to the a90/95 terminology used in industry recognized Probability-of-Detection assessments. Future work is proposed to apply the statistical analysis technique to quantify measurement precision of various thickness calculation methods under different environmental conditions such as high temperature, rough back-wall surface, and system degradation with an intended application to monitor naphthenic acid corrosion in oil refineries.
Find tools for primary standards for Nitrogen Dioxide, maps of monitoring areas, an overview of the proposal, monitor requirements, design values for counties, and a presentation on the 2010 NO2 primary NAAQS revision.
Journal Article: Quality Assurance Considerations for An Ambient Dioxin Monitoring Network
The U.S. Environmental Protection Agency initiated the National Dioxin Air Monitoring Network (NDAMN) in 1998. NDAMN has three primary purposes:
1. To provide measurements of background atmospheric levels of dioxin-like compounds in different geographic regions of the Unite...
Active Ground Optical Remote Sensing for Improved Monitoring of Seedling Stress in Nurseries
USDA-ARS?s Scientific Manuscript database
Active ground optical remote sensing (AGORS) devices mounted on overhead irrigation booms could help to improve seedling quality by autonomously monitoring seedling stress. In contrast to traditionally used passive optical sensors, AGORS devices operate independently of ambient light conditions and ...
Many epidemiologic studies of the health effects of exposure to ambient air pollution use measurements from central-site monitors as their exposure estimate. However, measurements from central-site monitors may lack the spatial and temporal resolution required to capture exposure...
EPA's mobile monitoring of source emissions and near-source impact
Real-time ambient monitoring onboard a moving vehicle is a unique data collection approach applied to characterize large-area sources, such as major roadways, and detect fugitive emissions from distributed sources, such as leaking oil wells. EPA's Office of Research and Developme...
Advanced Infant Car Seat Would Increase Highway Safety
NASA Technical Reports Server (NTRS)
Dabney, Richard; Elrod, Susan
2004-01-01
An advanced infant car seat has been proposed to increase highway safety by reducing the incidence of crying, fussy behavior, and other child-related distractions that divert an adult driver s attention from driving. In addition to a conventional infant car seat with safety restraints, the proposed advanced infant car seat would include a number of components and subsystems that would function together as a comprehensive infant-care system that would keep its occupant safe, comfortable, and entertained, and would enable the driver to monitor the baby without having to either stop the car or turn around to face the infant during driving. The system would include a vibrator with bulb switch to operate; the switch would double as a squeeze toy that would make its own specific sound. A music subsystem would include loudspeakers built into the seat plus digital and analog circuitry that would utilize plug-in memory modules to synthesize music or a variety of other sounds. The music subsystem would include a built-in sound generator that could synthesize white noise or a human heartbeat to calm the baby to sleep. A second bulb switch could be used to control the music subsystem and would double as a squeeze toy that would make a distinct sound. An anti-noise sound-suppression system would isolate the baby from potentially disturbing ambient external noises. This subsystem would include small microphones, placed near the baby s ears, to detect ambient noise. The outputs of the microphone would be amplified and fed to the loudspeakers at appropriate amplitude and in a phase opposite that of the detected ambient noise, such that the net ambient sound arriving at the baby s ears would be almost completely cancelled. A video-camera subsystem would enable the driver to monitor the baby visually while continuing to face forward. One or more portable miniature video cameras could be embedded in the side of the infant car seat (see figure) or in a flip-down handle. The outputs of the video cameras would be transmitted by radio or infrared to a portable, miniature receiver/video monitor unit that would be attached to the dashboard of the car. The video-camera subsystem can also be used within transmission/reception range when the seat was removed from the car. The system would include a biotelemetric and tracking subsystem, which would include a Global Positioning System receiver for measuring its location. This subsystem would transmit the location of the infant car seat (even if the seat were not in a car) along with such biometric data as the baby s heart rate, perspiration rate, urinary status, temperature, and rate of breathing. Upon detecting any anomalies in the biometric data, this subsystem would send a warning to a paging device installed in the car or carried by the driver, so that the driver could pull the car off the road to attend to the baby. A motion detector in this subsystem would send a warning if the infant car seat were to be moved or otherwise disturbed unexpectedly while the infant was seated in it: this warning function, in combination with the position- tracking function, could help in finding a baby who had been kidnapped with the seat. Removable rechargeable batteries would enable uninterrupted functioning of all parts of the system while transporting the baby to and from the car. The batteries could be recharged via the cigarette-lighter outlet in the car or by use of an external AC-powered charger.
Sonnenfroh, D M; Allen, M G
1997-10-20
We describe the development of a room-temperature diode sensor for in situ monitoring of combustion-generated NO. The sensor is based on a near-IR diode laser operating near 1.8 mum, which probes isolated transitions in the second overtone (3, 0) absorption band of NO. Based on absorption cell data, the sensitivity for ambient atmospheric pressure conditions is of the order of 30 parts in 10(6) by volume for a meter path (ppmv-m), assuming a minimum measurable absorbance of 10(-5). Initial H(2) -air flame measurements are complicated by strong water vapor absorption features that constrain the available gain and dynamic range of the present detection system. Preliminary results suggest that detection limits in this environment of the order of 140 ppmv-m could be achieved with optimum baseline correction.
NASA Astrophysics Data System (ADS)
Sonnenfroh, David M.; Allen, Mark G.
1997-10-01
We describe the development of a room-temperature diode sensor for in situ monitoring of combustion-generated NO. The sensor is based on a near-IR diode laser operating near 1.8 m, which probes isolated transitions in the second overtone (3,0) absorption band of NO. Based on absorption cell data, the sensitivity for ambient atmospheric pressure conditions is of the order of 30 parts in 10 6 by volume for a meter path (ppmv m), assuming a minimum measurable absorbance of 10 5 . Initial H 2 air flame measurements are complicated by strong water vapor absorption features that constrain the available gain and dynamic range of the present detection system. Preliminary results suggest that detection limits in this environment of the order of 140 ppmv m could be achieved with optimum baseline correction.
Pszona, S; Bantsar, A; Tulik, P; Wincel, K; Zaręba, B
2014-10-01
It has been shown that a proportional counter filled with (3)He placed centrally inside a polythene sphere opens a new possibility for measuring gamma photons and neutrons in the separate pulse-height windows. The responses to gamma and neutrons (in terms of ambient dose equivalent) of the detector assembly consisting of 203-mm polythene sphere with centrally positioned 40-mm diameter (3)He proportional counter have been studied. The response to secondary gammas from capture process in hydrogen has also been studied. The rather preliminary studies indicate that the proposed measuring system has very promising features as an ambient dose equivalent device for mixed gamma-neutron fields. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Earthquake and ambient vibration monitoring of the steel-frame UCLA factor building
Kohler, M.D.; Davis, P.M.; Safak, E.
2005-01-01
Dynamic property measurements of the moment-resisting steel-frame University of California, Los Angeles, Factor building are being made to assess how forces are distributed over the building. Fourier amplitude spectra have been calculated from several intervals of ambient vibrations, a 24-hour period of strong winds, and from the 28 March 2003 Encino, California (ML = 2.9), the 3 September 2002 Yorba Linda, California (ML = 4.7), and the 3 November 2002 Central Alaska (Mw = 7.9) earthquakes. Measurements made from the ambient vibration records show that the first-mode frequency of horizontal vibration is between 0.55 and 0.6 Hz. The second horizontal mode has a frequency between 1.6 and 1.9 Hz. In contrast, the first-mode frequencies measured from earthquake data are about 0.05 to 0.1 Hz lower than those corresponding to ambient vibration recordings indicating softening of the soil-structure system as amplitudes become larger. The frequencies revert to pre-earthquake levels within five minutes of the Yorba Linda earthquake. Shaking due to strong winds that occurred during the Encino earthquake dominates the frequency decrease, which correlates in time with the duration of the strong winds. The first shear wave recorded from the Encino and Yorba Linda earthquakes takes about 0.4 sec to travel up the 17-story building. ?? 2005, Earthquake Engineering Research Institute.
NASA Technical Reports Server (NTRS)
Chapman, K. B.; Mihaylov, G. M.; Kirollos, K. S.
2000-01-01
Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.
Hydrogel-coated fiber Bragg grating sensor for pH monitoring
NASA Astrophysics Data System (ADS)
Pabbisetti, Vayu Nandana Kishore; Madhuvarasu, Sai Shankar
2016-06-01
We present a fiber-optic wavelength-modulated sensor for pH applications. Fiber Bragg grating (FBG) is functionalized with a stimulus-responsive hydrogel that induces a strain on FBG due to mechanical expansion of the gel in response to ambient pH changes. The gel is synthesized from the blends of poly (vinyl alcohol)/poly (acrylic acid). The induced strain results in a shift of FBG reflected peak that is monitored by an interrogator. The sensor system shows good linearity in the acidic pH range of 3 to 7 with a sensitivity of 12.16 pm/pH. In addition, it shows good repeatability and oscillator behavior, which proves it to be fit for pH sensing applications.
Field Test of Boiler Primary Loop Temperature Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glanville, P.; Rowley, P.; Schroeder, D.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and, in some cases, return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential.« less
Radiological image presentation requires consideration of human adaptation characteristics
NASA Astrophysics Data System (ADS)
O'Connell, N. M.; Toomey, R. J.; McEntee, M.; Ryan, J.; Stowe, J.; Adams, A.; Brennan, P. C.
2008-03-01
Visualisation of anatomical or pathological image data is highly dependent on the eye's ability to discriminate between image brightnesses and this is best achieved when these data are presented to the viewer at luminance levels to which the eye is adapted. Current ambient light recommendations are often linked to overall monitor luminance but this relies on specific regions of interest matching overall monitor brightness. The current work investigates the luminances of specific regions of interest within three image-types: postero-anterior (PA) chest; PA wrist; computerised tomography (CT) of the head. Luminance levels were measured within the hilar region and peripheral lung distal radius and supra-ventricular grey matter. For each image type average monitor luminances were calculated with a calibrated photometer at ambient light levels of 0, 100 and 400 lux. Thirty samples of each image-type were employed, resulting in a total of over 6,000 measurements. Results demonstrate that average monitor luminances varied from clinically-significant values by up to a factor of 4, 2 and 6 for chest, wrist and CT head images respectively. Values for the thoracic hilum and wrist were higher and for the peripheral lung and CT brain lower than overall monitor levels. The ambient light level had no impact on the results. The results demonstrate that clinically important radiological information for common radiological examinations is not being presented to the viewer in a way that facilitates optimised visual adaptation and subsequent interpretation. The importance of image-processing algorithms focussing on clinically-significant anatomical regions instead of radiographic projections is highlighted.
Power system distributed oscilation detection based on Synchrophasor data
NASA Astrophysics Data System (ADS)
Ning, Jiawei
Along with increasing demand for electricity, integration of renewable energy and deregulation of power market, power industry is facing unprecedented challenges nowadays. Within the last couple of decades, several serious blackouts have been taking place in United States. As an effective approach to prevent that, power system small signal stability monitoring has been drawing more interests and attentions from researchers. With wide-spread implementation of Synchrophasors around the world in the last decade, power systems real-time online monitoring becomes much more feasible. Comparing with planning study analysis, real-time online monitoring would benefit control room operators immediately and directly. Among all online monitoring methods, Oscillation Modal Analysis (OMA), a modal identification method based on routine measurement data where the input is unmeasured ambient excitation, is a great tool to evaluate and monitor power system small signal stability. Indeed, high sampling Synchrophasor data around power system is fitted perfectly as inputs to OMA. Existing methods in OMA for power systems are all based on centralized algorithms applying at control centers only; however, with rapid growing number of online Synchrophasors the computation burden at control centers is and will be continually exponentially expanded. The increasing computation time at control center compromises the real-time feature of online monitoring. The communication efforts between substation and control center will also be out of reach. Meanwhile, it is difficult or even impossible for centralized algorithms to detect some poorly damped local modes. In order to avert previous shortcomings of centralized OMA methods and embrace the new changes in the power systems, two new distributed oscillation detection methods with two new decentralized structures are presented in this dissertation. Since the new schemes brought substations into the big oscillation detection picture, the proposed methods could achieve faster and more reliable results. Subsequently, this claim is tested and approved by test results of IEEE Two-area simulation test system and real power system historian synchrophasor data case studies.
Code of Federal Regulations, 2013 CFR
2013-07-01
... monitors utilize the same specific sampling and analysis method. Combined site data record is the data set... monitors are suitable monitors designated by a state or local agency in their annual network plan (and in... appendix. Seasonal sampling is the practice of collecting data at a reduced frequency during a season of...
40 CFR Appendix D to Part 58 - Network Design Criteria for Ambient Air Quality Monitoring
Code of Federal Regulations, 2010 CFR
2010-07-01
... residential district. In this case, one location is representative of a neighborhood of small scale sites and... least one of the required FRM/FEM/ARM monitors is itself a continuous FEM or ARM monitor in which case... studies. 4.7.5Special Network Considerations Required When Using PM2.5 Spatial Averaging Approaches. (a...
40 CFR Appendix D to Part 58 - Network Design Criteria for Ambient Air Quality Monitoring
Code of Federal Regulations, 2012 CFR
2012-07-01
... residential district. In this case, one location is representative of a neighborhood of small scale sites and... least one of the required FRM/FEM/ARM monitors is itself a continuous FEM or ARM monitor in which case... studies. 4.7.5Special Network Considerations Required When Using PM2.5 Spatial Averaging Approaches. (a...
40 CFR Appendix D to Part 58 - Network Design Criteria for Ambient Air Quality Monitoring
Code of Federal Regulations, 2011 CFR
2011-07-01
... residential district. In this case, one location is representative of a neighborhood of small scale sites and... least one of the required FRM/FEM/ARM monitors is itself a continuous FEM or ARM monitor in which case... studies. 4.7.5Special Network Considerations Required When Using PM2.5 Spatial Averaging Approaches. (a...
Sensor-Only System Identification for Structural Health Monitoring of Advanced Aircraft
NASA Technical Reports Server (NTRS)
Kukreja, Sunil L.; Bernstein, Dennis S.
2012-01-01
Environmental conditions, cyclic loading, and aging contribute to structural wear and degradation, and thus potentially catastrophic events. The challenge of health monitoring technology is to determine incipient changes accurately and efficiently. This project addresses this challenge by developing health monitoring techniques that depend only on sensor measurements. Since actively controlled excitation is not needed, sensor-to-sensor identification (S2SID) provides an in-flight diagnostic tool that exploits ambient excitation to provide advance warning of significant changes. S2SID can subsequently be followed up by ground testing to localize and quantify structural changes. The conceptual foundation of S2SID is the notion of a pseudo-transfer function, where one sensor is viewed as the pseudo-input and another is viewed as the pseudo-output, is approach is less restrictive than transmissibility identification and operational modal analysis since no assumption is made about the locations of the sensors relative to the excitation.
NASA Technical Reports Server (NTRS)
Srivatsan, Raghavachari; Downing, David R.
1987-01-01
Discussed are the development and testing of a real-time takeoff performance monitoring algorithm. The algorithm is made up of two segments: a pretakeoff segment and a real-time segment. One-time imputs of ambient conditions and airplane configuration information are used in the pretakeoff segment to generate scheduled performance data for that takeoff. The real-time segment uses the scheduled performance data generated in the pretakeoff segment, runway length data, and measured parameters to monitor the performance of the airplane throughout the takeoff roll. Airplane and engine performance deficiencies are detected and annunciated. An important feature of this algorithm is the one-time estimation of the runway rolling friction coefficient. The algorithm was tested using a six-degree-of-freedom airplane model in a computer simulation. Results from a series of sensitivity analyses are also included.
Structural health monitoring using wireless sensor networks
NASA Astrophysics Data System (ADS)
Sreevallabhan, K.; Nikhil Chand, B.; Ramasamy, Sudha
2017-11-01
Monitoring and analysing health of large structures like bridges, dams, buildings and heavy machinery is important for safety, economical, operational, making prior protective measures, and repair and maintenance point of view. In recent years there is growing demand for such larger structures which in turn make people focus more on safety. By using Microelectromechanical Systems (MEMS) Accelerometer we can perform Structural Health Monitoring by studying the dynamic response through measure of ambient vibrations and strong motion of such structures. By using Wireless Sensor Networks (WSN) we can embed these sensors in wireless networks which helps us to transmit data wirelessly thus we can measure the data wirelessly at any remote location. This in turn reduces heavy wiring which is a cost effective as well as time consuming process to lay those wires. In this paper we developed WSN based MEMS-accelerometer for Structural to test the results in the railway bridge near VIT University, Vellore campus.
NASA Astrophysics Data System (ADS)
Gonzales, Melissa
To evaluate those factors which influence the assignment of ozone ( O3) exposures in an epidemiologic context a field study was conducted in the South Coast Air Basin (SoCAB) during the summer of 19% in which time, location, activity (TLA) information and direct measurements of personal O3 exposure were concurrently collected on a group of college students. Current and past O3 exposures were modeled and evaluated as a function of ambient O 3, activity and mobility patterns, indoor ventilation, and recalled TLA information collected one year later. The effect of these factors on the within- and between-subject exposure variability assigned by ecologic (EC) and microenvironment (MEV) models were examined by two-hour intervals, on weekends and weekdays, and by monitoring week compared to personal exposures measured with a passive sampling device (PSD). The students reported spending 85% of their time inside, 7% outside and 8% in- transit. More time was spent outdoors on weekends than on weekdays. Ambient O3 levels were also higher on weekends. In the study area, where a dense O3 monitoring network and the appropriate topography exist fixed-site O3 accurately assigned ambient O3 levels within a 10 mile radius. The variation in the ecologic exposure assignments was low compared to the estimated variation among PSD-measured and MEV-modeled estimates due to the low spatial variation of ambient O3 levels across the SoCAB areas visited by the students. MEV and PSD exposure estimates better captured the variability of personal exposure in any given ambient spatial regimen compared to ecologic exposure assignments. MEV exposure estimates based on recalled TLA patterns, were similar to the MEV estimates based on diary-recorded TLA patterns. For this study population, PSD-measured O3 exposures were estimated to average 32% lower than ``true'' exposure levels due to indoor/outdoor differences in the PSD collection rate. The level of detail obtained from the TLA diary is not necessary for the assignment of current of past O3 exposures in epidemiologic studies. It may be more adventitious to characterize the locations visited, and indoor and outdoor time with the greatest accuracy possible and to use these data to estimate exposure from nearest-monitor ambient O 3 measurements and sets of indoor/outdoor O3 ratios validated to reflect personal exposure within indoor microenvironments.
Forecasting long-range atmospheric transport episodes of polychlorinated biphenyls using FLEXPART
NASA Astrophysics Data System (ADS)
Halse, Anne Karine; Eckhardt, Sabine; Schlabach, Martin; Stohl, Andreas; Breivik, Knut
2013-06-01
The analysis of concentrations of persistent organic pollutants (POPs) in ambient air is costly and can only be done for a limited number of samples. It is thus beneficial to maximize the information content of the samples analyzed via a targeted observation strategy. Using polychlorinated biphenyls (PCBs) as an example, a forecasting system to predict and evaluate long-range atmospheric transport (LRAT) episodes of POPs at a remote site in southern Norway has been developed. The system uses the Lagrangian particle transport model FLEXPART, and can be used for triggering extra ("targeted") sampling when LRAT episodes are predicted to occur. The system was evaluated by comparing targeted samples collected over 12-25 h during individual LRAT episodes with monitoring samples regularly collected over one day per week throughout a year. Measured concentrations in all targeted samples were above the 75th percentile of the concentrations obtained from the regular monitoring program and included the highest measured values of all samples. This clearly demonstrates the success of the targeted sampling strategy.
Modeling of lead air pollution. [Baton Rouge, Louisiana
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monteith, C.S.; Henry, J.M.
1982-05-01
A study was performed to determine whether vehicular emissions should be included with industrial emissions when demonstrating attainment of the ambient air quality standard for lead. The impact on ambient lead concentrations of the phaseout of leaded gasoline and improved automobile fuel economy was examined by modeling vehicular emissions for 1972 and 1978. Results show that while automobiles in the Baton Rouge area were a significant source of lead in 1972, the phaseout of leaded gasoline and the increase in fuel economy have resulted in a lower contribution (0.20 ..mu..g/m/sup 3/) by automobiles to the ambient lead concentration in 1978.more » The areas having the greatest potential for exceeding the ambient air quality standard can be identified using CDM (EPA's Climatological Dispersion Model). This information can be used to determine the optimal location for an ambient air monitor to demonstrate compliance with the ambient air quality standard. 9 references, 4 figures, 5 tables. (JMT)« less
A miniature batteryless health and usage monitoring system based on hybrid energy harvesting
NASA Astrophysics Data System (ADS)
Huang, Chenling; Chakrabartty, Shantanu
2011-04-01
The cost and size of the state-of-the-art health and usage monitoring systems (HUMS) are determined by capacity of on-board energy storage which limits their large scale deployment. In this paper, we present a miniature low-cost mechanical HUMS integrated circuit (IC) based on the concept of hybrid energy harvesting where continuous monitoring is achieved by self-powering, where as the programming, localization and communication with the sensor is achieved using remote RF powering. The self-powered component of the proposed HUMS is based on our previous result which used a controllable hot electron injection on floatinggate transistor as an ultra-low power signal processor. We show that the HUMS IC can seamlessly switch between different energy harvesting modes based on the availability of ambient RF power and that the configuration, programming and communication functions can be remotely performed without physically accessing the HUMS device. All the measured results presented in this paper have been obtained from prototypes fabricated in a 0.5 micron standard CMOS process and the entire system has been successfully integrated on a 1.5cm x 1.5cm package.
The Next-Generation PCR-Based Quantification Method for Ambient Waters: Digital PCR.
Cao, Yiping; Griffith, John F; Weisberg, Stephen B
2016-01-01
Real-time quantitative PCR (qPCR) is increasingly being used for ambient water monitoring, but development of digital polymerase chain reaction (digital PCR) has the potential to further advance the use of molecular techniques in such applications. Digital PCR refines qPCR by partitioning the sample into thousands to millions of miniature reactions that are examined individually for binary endpoint results, with DNA density calculated from the fraction of positives using Poisson statistics. This direct quantification removes the need for standard curves, eliminating the labor and materials associated with creating and running standards with each batch, and removing biases associated with standard variability and mismatching amplification efficiency between standards and samples. Confining reactions and binary endpoint measurements to small partitions also leads to other performance advantages, including reduced susceptibility to inhibition, increased repeatability and reproducibility, and increased capacity to measure multiple targets in one analysis. As such, digital PCR is well suited for ambient water monitoring applications and is particularly advantageous as molecular methods move toward autonomous field application.
Corredor, Iván; Metola, Eduardo; Bernardos, Ana M; Tarrío, Paula; Casar, José R
2014-04-29
In the last few years, many health monitoring systems have been designed to fullfil the needs of a large range of scenarios. Although many of those systems provide good ad hoc solutions, most of them lack of mechanisms that allow them to be easily reused. This paper is focused on describing an open platform, the micro Web of Things Open Platform (µWoTOP), which has been conceived to improve the connectivity and reusability of context data to deliver different kinds of health, wellness and ambient home care services. µWoTOP is based on a resource-oriented architecture which may be embedded in mobile and resource constrained devices enabling access to biometric, ambient or activity sensors and actuator resources through uniform interfaces defined according to a RESTful fashion. Additionally, µWoTOP manages two communication modes which allow delivering user context information according to different methods, depending on the requirements of the consumer application. It also generates alert messages based on standards related to health care and risk management, such as the Common Alerting Protocol, in order to make its outputs compatible with existing systems.
Ambient agents: embedded agents for remote control and monitoring using the PANGEA platform.
Villarrubia, Gabriel; De Paz, Juan F; Bajo, Javier; Corchado, Juan M
2014-07-31
Ambient intelligence has advanced significantly during the last few years. The incorporation of image processing and artificial intelligence techniques have opened the possibility for such aspects as pattern recognition, thus allowing for a better adaptation of these systems. This study presents a new model of an embedded agent especially designed to be implemented in sensing devices with resource constraints. This new model of an agent is integrated within the PANGEA (Platform for the Automatic Construction of Organiztions of Intelligent Agents) platform, an organizational-based platform, defining a new sensor role in the system and aimed at providing contextual information and interacting with the environment. A case study was developed over the PANGEA platform and designed using different agents and sensors responsible for providing user support at home in the event of incidents or emergencies. The system presented in the case study incorporates agents in Arduino hardware devices with recognition modules and illuminated bands; it also incorporates IP cameras programmed for automatic tracking, which can connect remotely in the event of emergencies. The user wears a bracelet, which contains a simple vibration sensor that can receive notifications about the emergency situation.
Ambient Agents: Embedded Agents for Remote Control and Monitoring Using the PANGEA Platform
Villarrubia, Gabriel; De Paz, Juan F.; Bajo, Javier; Corchado, Juan M.
2014-01-01
Ambient intelligence has advanced significantly during the last few years. The incorporation of image processing and artificial intelligence techniques have opened the possibility for such aspects as pattern recognition, thus allowing for a better adaptation of these systems. This study presents a new model of an embedded agent especially designed to be implemented in sensing devices with resource constraints. This new model of an agent is integrated within the PANGEA (Platform for the Automatic Construction of Organiztions of Intelligent Agents) platform, an organizational-based platform, defining a new sensor role in the system and aimed at providing contextual information and interacting with the environment. A case study was developed over the PANGEA platform and designed using different agents and sensors responsible for providing user support at home in the event of incidents or emergencies. The system presented in the case study incorporates agents in Arduino hardware devices with recognition modules and illuminated bands; it also incorporates IP cameras programmed for automatic tracking, which can connect remotely in the event of emergencies. The user wears a bracelet, which contains a simple vibration sensor that can receive notifications about the emergency situation. PMID:25090416
Corredor, Iván; Metola, Eduardo; Bernardos, Ana M.; Tarrío, Paula; Casar, José R.
2014-01-01
In the last few years, many health monitoring systems have been designed to fullfil the needs of a large range of scenarios. Although many of those systems provide good ad hoc solutions, most of them lack of mechanisms that allow them to be easily reused. This paper is focused on describing an open platform, the micro Web of Things Open Platform (µWoTOP), which has been conceived to improve the connectivity and reusability of context data to deliver different kinds of health, wellness and ambient home care services. µWoTOP is based on a resource-oriented architecture which may be embedded in mobile and resource constrained devices enabling access to biometric, ambient or activity sensors and actuator resources through uniform interfaces defined according to a RESTful fashion. Additionally, µWoTOP manages two communication modes which allow delivering user context information according to different methods, depending on the requirements of the consumer application. It also generates alert messages based on standards related to health care and risk management, such as the Common Alerting Protocol, in order to make its outputs compatible with existing systems. PMID:24785542
Enhanced Raman Monitor Project
NASA Technical Reports Server (NTRS)
Westenskow, Dwayne
1996-01-01
Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.
RESULTS FROM EXPOSURE MONITORING PERFORMED DURING THE 1997 BALTIMORE PM PILOT STUDY
An eighteen day winter-time ambient and personal exposure monitoring study of particulate matter (PM) was conducted as part of an.integrated epidemiological-exposure pilot study of an aged population. Goals of the study were to determine the feasibility of performing active per...
Exposure studies rely on detailed characterization of air quality, either from sparsely located routine ambient monitors or from central monitoring sites that may lack spatial representativeness. Alternatively, some studies use models of various complexities to characterize local...
SPRUCE Environmental Monitoring Data: 2010-2016
Hanson, P. J. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A; Riggs, J. S. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A; Forrance, C. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A; Nettles, W. R. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A; Hook, L. A. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A
2015-11-01
This data set reports selected ambient environmental monitoring data (public) from the S1 bog for the period June 2010 through 2016. Measurements of the environmental conditions at these stations will serve as a pre-treatment baseline for experimental treatments and provide driver data for future modeling activities.
Cassini, Rudi; Scremin, Mara; Contiero, Barbara; Drago, Andrea; Vettorato, Christian; Marcer, Federica; di Regalbono, Antonio Frangipane
2016-06-01
Ambient insecticides are receiving increasing attention in many developed countries because of their value in reducing mosquito nuisance. As required by the European Union Biocidal Products Regulation 528/2012, these devices require appropriate testing of their efficacy, which is based on estimating the knockdown and mortality rates of free-flying (free) mosquitoes in a test room. However, evaluations using free mosquitoes present many complexities. The performances of 6 alternative methods with mosquitoes held in 2 different cage designs (steel wire and gauze/plastic) with and without an operating fan for air circulation were monitored in a test room through a closed-circuit television system and were compared with the currently recommended method using free mosquitoes. Results for caged mosquitoes without a fan showed a clearly delayed knockdown effect, whereas outcomes for caged mosquitoes with a fan recorded higher mortality at 24 h, compared to free mosquitoes. Among the 6 methods, cages made of gauze and plastic operating with fan wind speed at 2.5-2.8 m/sec was the only method without a significant difference in results for free mosquitoes, and therefore appears as the best alternative to assess knockdown by ambient insecticides accurately.
A smartphone-based chip-scale microscope using ambient illumination.
Lee, Seung Ah; Yang, Changhuei
2014-08-21
Portable chip-scale microscopy devices can potentially address various imaging needs in mobile healthcare and environmental monitoring. Here, we demonstrate the adaptation of a smartphone's camera to function as a compact lensless microscope. Unlike other chip-scale microscopy schemes, this method uses ambient illumination as its light source and does not require the incorporation of a dedicated light source. The method is based on the shadow imaging technique where the sample is placed on the surface of the image sensor, which captures direct shadow images under illumination. To improve the image resolution beyond the pixel size, we perform pixel super-resolution reconstruction with multiple images at different angles of illumination, which are captured while the user is manually tilting the device around any ambient light source, such as the sun or a lamp. The lensless imaging scheme allows for sub-micron resolution imaging over an ultra-wide field-of-view (FOV). Image acquisition and reconstruction are performed on the device using a custom-built Android application, constructing a stand-alone imaging device for field applications. We discuss the construction of the device using a commercial smartphone and demonstrate the imaging capabilities of our system.
A smartphone-based chip-scale microscope using ambient illumination
Lee, Seung Ah; Yang, Changhuei
2014-01-01
Portable chip-scale microscopy devices can potentially address various imaging needs in mobile healthcare and environmental monitoring. Here, we demonstrate the adaptation of a smartphone’s camera to function as a compact lensless microscope. Unlike other chip-scale microscopy schemes, this method uses ambient illumination as its light source and does not require the incorporation of a dedicated light source. The method is based on the shadow imaging technique where the sample is placed on the surface of the image sensor, which captures direct shadow images under illumination. To improve the imaging resolution beyond the pixel size, we perform pixel super-resolution reconstruction with multiple images at different angles of illumination, which are captured while the user is manually tilting the device around any ambient light source, such as the sun or a lamp. The lensless imaging scheme allows for sub-micron resolution imaging over an ultra-wide field-of-view (FOV). Image acquisition and reconstruction is performed on the device using a custom-built android application, constructing a stand-alone imaging device for field applications. We discuss the construction of the device using a commercial smartphone and demonstrate the imaging capabilities of our system. PMID:24964209
Burden of disease attributed to ambient air pollution in Thailand: A GIS-based approach.
Pinichka, Chayut; Makka, Nuttapat; Sukkumnoed, Decharut; Chariyalertsak, Suwat; Inchai, Puchong; Bundhamcharoen, Kanitta
2017-01-01
Growing urbanisation and population requiring enhanced electricity generation as well as the increasing numbers of fossil fuel in Thailand pose important challenges to air quality management which impacts on the health of the population. Mortality attributed to ambient air pollution is one of the sustainable development goals (SDGs). We estimated the spatial pattern of mortality burden attributable to selected ambient air pollution in 2009 based on the empirical evidence in Thailand. We estimated the burden of disease attributable to ambient air pollution based on the comparative risk assessment (CRA) framework developed by the World Health Organization (WHO) and the Global Burden of Disease study (GBD). We integrated geographical information systems (GIS)-based exposure assessments into spatial interpolation models to estimate ambient air pollutant concentrations, the population distribution of exposure and the concentration-response (CR) relationship to quantify ambient air pollution exposure and associated mortality. We obtained air quality data from the Pollution Control Department (PCD) of Thailand surface air pollution monitoring network sources and estimated the CR relationship between relative risk (RR) and concentration of air pollutants from the epidemiological literature. We estimated 650-38,410 ambient air pollution-related fatalities and 160-5,982 fatalities that could have been avoided with a 20 reduction in ambient air pollutant concentrations. The summation of population-attributable fraction (PAF) of the disease burden for all-causes mortality in adults due to NO2 and PM2.5 were the highest among all air pollutants at 10% and 7.5%, respectively. The PAF summation of PM2.5 for lung cancer and cardiovascular disease were 16.8% and 14.6% respectively and the PAF summations of mortality attributable to PM10 was 3.4% for all-causes mortality, 1.7% for respiratory and 3.8% for cardiovascular mortality, while the PAF summation of mortality attributable to NO2 was 7.8% for respiratory mortality in Thailand. Mortality due to ambient air pollution in Thailand varies across the country. Geographical distribution estimates can identify high exposure areas for planners and policy-makers. Our results suggest that the benefits of a 20% reduction in ambient air pollution concentration could prevent up to 25% of avoidable fatalities each year in all-causes, respiratory and cardiovascular categories. Furthermore, our findings can provide guidelines for future epidemiological investigations and policy decisions to achieve the SDGs.
A high-frequency warm shallow water acoustic communications channel model and measurements.
Chitre, Mandar
2007-11-01
Underwater acoustic communication is a core enabling technology with applications in ocean monitoring using remote sensors and autonomous underwater vehicles. One of the more challenging underwater acoustic communication channels is the medium-range very shallow warm-water channel, common in tropical coastal regions. This channel exhibits two key features-extensive time-varying multipath and high levels of non-Gaussian ambient noise due to snapping shrimp-both of which limit the performance of traditional communication techniques. A good understanding of the communications channel is key to the design of communication systems. It aids in the development of signal processing techniques as well as in the testing of the techniques via simulation. In this article, a physics-based channel model for the very shallow warm-water acoustic channel at high frequencies is developed, which are of interest to medium-range communication system developers. The model is based on ray acoustics and includes time-varying statistical effects as well as non-Gaussian ambient noise statistics observed during channel studies. The model is calibrated and its accuracy validated using measurements made at sea.
NASA Astrophysics Data System (ADS)
Huang, H. H.; Hsu, Y. J.; Kuo, C. Y.; Chen, C. C.; Kuo, L. W.; Chen, R. F.; Lin, C. R.; Lin, P. P.; Lin, C. W.; Lin, M. L.; Wang, K. L.
2017-12-01
A unique landslide monitoring project integrating multidisciplinary geophysics experiments such as GPS, inclinometer, piezometer, and spontaneous potential log has been established at Lantai, Ilan area to investigating the possible detachment depth range and the physical mechanism of a slowly creeping landslide. In parallel with this, a lately deployed local seismic network also lends an opportunity to employ the passive seismic imaging technique to detect the time-lapse changes of seismic velocity in and around the landslide area. Such technique that retrieves Green's functions by cross-correlation of continuous ambient noise has opened new opportunities to seismologically monitoring the environmental and tectonic events such as ground water variation, magma intrusion under volcanos, and co-seismic medium damage in recent years. Integrating these geophysical observations, we explore the primary controls of derived seismic velocity changes and especially the hydrological response of the landslide to the passage of Megi typhoon in the last September 2016, which could potentially further our understanding of the dynamic system of landslides and in turn help the hazard mitigation.
NASA Astrophysics Data System (ADS)
Alm, S.; Mukala, K.; Tiittanen, P.; Jantunen, M. J.
The associations of personal carbon monoxide (CO) exposures with ambient air CO concentrations measured at fixed monitoring sites, were studied among 194 children aged 3-6 yr in four downtown and four suburban day-care centers in Helsinki, Finland. Each child carried a personal CO exposure monitor between 1 and 4 times for a time period of between 20 and 24 h. CO concentrations at two fixed monitoring sites were measured simultaneously. The CO concentrations measured at the fixed monitoring sites were usually lower (mean maximum 8-h concentration: 0.9 and 2.6 mg m -3) than the personal CO exposure concentrations (mean maximum 8-h concentration: 3.3 mg m -3). The fixed site CO concentrations were poor predictors of the personal CO exposure concentrations. However, the correlations between the personal CO exposure and the fixed monitoring site CO concentrations increased (-0.03--0.12 to 0.13-0.16) with increasing averaging times from 1 to 8 h. Also, the fixed monitoring site CO concentrations explained the mean daily or weekly personal CO exposures of a group of simultaneously measured children better than individual exposure CO concentrations. This study suggests that the short-term CO personal exposure of children cannot be meaningfully assessed using fixed monitoring sites.
Evaluation of aeolian emissions from gold mine tailings on the Witwatersrand
NASA Astrophysics Data System (ADS)
Ojelede, M. E.; Annegarn, H. J.; Kneen, M. A.
2012-01-01
The Witwatersrand is known for the high frequency of aeolian dust storm episodes arising from gold mine tailings storage facilities (TSFs). Source and ambient atmosphere are poorly characterized from the point of view of particle size distribution and human health risk assessment. For years, routine monitoring was limited to sampling of dust fallout ⩾30 μm. Sampling and analyses of source and receptor material was conducted. Thirty-two bulk soils were collected from TSF along the east-west mining corridor, and size distribution analysis was performed in the range 0.05-900 μm using a Malvern® MS-14 Particle Size Analyser. Ambient aerosols in the range 0.25-32 μm were monitored at two separate locations using a Grimm® aerosol monitor, in the vicinity of three large currently active and a dormant TSF. Statistical analyses indicate that TSFs are rich in fine erodible materials, particularly active TSFs. Concentration of ⩽PM5 and ⩽PM10 components in source material was: recent slimes (14-24 vol.%; 22-38 vol.%), older slimes (6-17 vol.%; 11-26 vol.%) and sand (1-8 vol.%; 2-12 vol.%). Concentrations of airborne aerosols were below the South African Department of Environmental Affairs 24-h limit value of 120 μg m -3. With wind speeds exceeding 7 ms -1, ambient concentration reached 2160 μg m -3. This maximum is several times higher than the limit value. Erosion of tailings storage facilities is a strong driver influencing ambient particulate matter loading with adverse health implications for nearby residents.
Detection capability of the IMS seismic network based on ambient seismic noise measurements
NASA Astrophysics Data System (ADS)
Gaebler, Peter J.; Ceranna, Lars
2016-04-01
All nuclear explosions - on the Earth's surface, underground, underwater or in the atmosphere - are banned by the Comprehensive Nuclear-Test-Ban Treaty (CTBT). As part of this treaty, a verification regime was put into place to detect, locate and characterize nuclear explosion testings at any time, by anyone and everywhere on the Earth. The International Monitoring System (IMS) plays a key role in the verification regime of the CTBT. Out of the different monitoring techniques used in the IMS, the seismic waveform approach is the most effective technology for monitoring nuclear underground testing and to identify and characterize potential nuclear events. This study introduces a method of seismic threshold monitoring to assess an upper magnitude limit of a potential seismic event in a certain given geographical region. The method is based on ambient seismic background noise measurements at the individual IMS seismic stations as well as on global distance correction terms for body wave magnitudes, which are calculated using the seismic reflectivity method. From our investigations we conclude that a global detection threshold of around mb 4.0 can be achieved using only stations from the primary seismic network, a clear latitudinal dependence for the detection threshold can be observed between northern and southern hemisphere. Including the seismic stations being part of the auxiliary seismic IMS network results in a slight improvement of global detection capability. However, including wave arrivals from distances greater than 120 degrees, mainly PKP-wave arrivals, leads to a significant improvement in average global detection capability. In special this leads to an improvement of the detection threshold on the southern hemisphere. We further investigate the dependence of the detection capability on spatial (latitude and longitude) and temporal (time) parameters, as well as on parameters such as source type and percentage of operational IMS stations.
Photochemical Assessment Monitoring Stations (PAMS)
Photochemical Assessment Monitoring Stations (PAMS). This file provides information on the numbers and distribution (latitude/longitude) of air monitoring sites which measure ozone precursors (approximately 60 volatile hydrocarbons and carbonyl), as required by the 1990 Clean Air Act Amendments, in areas with persistently high ozone levels (mostly large metropolitan areas). In these areas, the States have established ambient air monitoring sites which collect and report detailed data for volatile organic compounds, nitrogen oxides, ozone and meteorological parameters. This file displays 199 monitoring sites reporting measurements for 2010. A wide range of related monitoring site attributes is also provided.
Single-station monitoring of volcanoes using seismic ambient noise
NASA Astrophysics Data System (ADS)
De Plaen, Raphael S. M.; Lecocq, Thomas; Caudron, Corentin; Ferrazzini, Valérie; Francis, Olivier
2016-08-01
Seismic ambient noise cross correlation is increasingly used to monitor volcanic activity. However, this method is usually limited to volcanoes equipped with large and dense networks of broadband stations. The single-station approach may provide a powerful and reliable alternative to the classical "cross-station" approach when measuring variation of seismic velocities. We implemented it on the Piton de la Fournaise in Reunion Island, a very active volcano with a remarkable multidisciplinary continuous monitoring. Over the past decade, this volcano has been increasingly studied using the traditional cross-correlation technique and therefore represents a unique laboratory to validate our approach. Our results, tested on stations located up to 3.5 km from the eruptive site, performed as well as the classical approach to detect the volcanic eruption in the 1-2 Hz frequency band. This opens new perspectives to successfully forecast volcanic activity at volcanoes equipped with a single three-component seismometer.
Maintaining Perioperative Normothermia: Sustaining an Evidence-Based Practice Improvement Project.
Levin, Rona F; Wright, Fay; Pecoraro, Kathleen; Kopec, Wendy
2016-02-01
Unintentional perioperative hypothermia has been shown to cause serious patient complications and, thus, to increase health care costs. In 2009, an evidence-based practice improvement project produced a significant decrease in unintentional perioperative hypothermia in colorectal surgical patients through monitoring of OR ambient room temperature. Project leaders engaged all interdisciplinary stakeholders in the original project, which facilitated the sustainability of the intervention method. An important aspect of sustainability is ongoing monitoring and evaluation of a new intervention method. Therefore, continued evaluation of outcomes of the protocol developed in 2009 was scheduled at specific time points after the initial small test of change with colorectal patients. This article focuses on how attention to sustainability factors during implementation of an improvement project led to the sustainability of a protocol for monitoring OR ambient room temperature with all types of surgical patients five years after the initial project. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Malm, William C.; Day, Derek E.; Carrico, Christian; Kreidenweis, Sonia M.; Collett, Jeffrey L.; McMeeking, Gavin; Lee, Taehyoung; Carrillo, Jacqueline; Schichtel, Bret
2005-07-01
Physical and optical properties of inorganic aerosols have been extensively studied, but less is known about carbonaceous aerosols, especially as they relate to the non-urban settings such as our nation's national parks and wilderness areas. Therefore an aerosol characterization study was conceived and implemented at one national park that is highly impacted by carbonaceous aerosols, Yosemite. The primary objective of the study was to characterize the physical, chemical, and optical properties of a carbon-dominated aerosol, including the ratio of total organic matter weight to organic carbon, organic mass scattering efficiencies, and the hygroscopic characteristics of a carbon-laden ambient aerosol, while a secondary objective was to evaluate a variety of semi-continuous monitoring systems. Inorganic ions were characterized using 24-hour samples that were collected using the URG and Interagency Monitoring of Protected Visual Environments (IMPROVE) monitoring systems, the micro-orifice uniform deposit impactor (MOUDI) cascade impactor, as well as the semi-continuous particle-into-liquid sampler (PILS) technology. Likewise, carbonaceous material was collected over 24-hour periods using IMPROVE technology along with the thermal optical reflectance (TOR) analysis, while semi-continuous total carbon concentrations were measured using the Rupprecht and Patashnick (R&P) instrument. Dry aerosol number size distributions were measured using a differential mobility analyzer (DMA) and optical particle counter, scattering coefficients at near-ambient conditions were measured with nephelometers fitted with PM10 and PM2.5 inlets, and "dry" PM2.5 scattering was measured after passing ambient air through Perma Pure Nafion® dryers. In general, the 24-hour "bulk" measurements of various aerosol species compared more favorably with each other than with the semi-continuous data. Semi-continuous sulfate measurements correlated well with the 24-hour measurements, but were biased low by about 0.15 μg/m3. Semi-continuous carbon concentrations did not compare favorably with 24-hour measurements. Fine mass closure calculations suggested that the factor for estimating organic mass from measurements of carbon was approximately 1.8. Furthermore, fine scattering closure calculations showed that the use of 4.0 m2/g for the fine organic mass scattering coefficient was an underestimate by at least 30% for periods with high organic mass concentrations.
Release of Bet v 1 from birch pollen from 5 European countries. Results from the HIALINE study
NASA Astrophysics Data System (ADS)
Buters, Jeroen T. M.; Thibaudon, Michel; Smith, Matt; Kennedy, Roy; Rantio-Lehtimäki, Auli; Albertini, Roberto; Reese, Gerald; Weber, Bernhard; Galan, Carmen; Brandao, Rui; Antunes, Celia M.; Jäger, Siegfried; Berger, Uwe; Celenk, Sevcan; Grewling, Łukasz; Jackowiak, Bogdan; Sauliene, Ingrida; Weichenmeier, Ingrid; Pusch, Gudrun; Sarioglu, Hakan; Ueffing, Marius; Behrendt, Heidrun; Prank, Marje; Sofiev, Mikhail; Cecchi, Lorenzo; Hialine Working Group
2012-08-01
Exposure to allergens is pivotal in determining sensitization and allergic symptoms in individuals. Pollen grain counts in ambient air have traditionally been assessed to estimate airborne allergen exposure. However, the exact allergen content of ambient air is unknown. We therefore monitored atmospheric concentrations of birch pollen grains and the matched major birch pollen allergen Bet v 1 simultaneously across Europe within the EU-funded project HIALINE (Health Impacts of Airborne Allergen Information Network). Pollen count was assessed with Hirst type pollen traps at 10 l min-1 at sites in France, United Kingdom, Germany, Italy and Finland. Allergen concentrations in ambient air were sampled at 800 l min-1 with a Chemvol® high-volume cascade impactor equipped with stages PM > 10 μm, 10 μm > PM > 2.5 μm, and in Germany also 2.5 μm > PM > 0.12 μm. The major birch pollen allergen Bet v 1 was determined with an allergen specific ELISA. Bet v 1 isoform patterns were analyzed by 2D-SDS-PAGE blots and mass spectrometric identification. Basophil activation was tested in an FcɛR1-humanized rat basophil cell line passively sensitized with serum of a birch pollen symptomatic patient. Compared to 10 previous years, 2009 was a representative birch pollen season for all stations. About 90% of the allergen was found in the PM > 10 μm fraction at all stations. Bet v 1 isoforms pattern did not vary substantially neither during ripening of pollen nor between different geographical locations. The average European allergen release from birch pollen was 3.2 pg Bet v 1/pollen and did not vary much between the European countries. However, in all countries a >10-fold difference in daily allergen release per pollen was measured which could be explained by long-range transport of pollen with a deviating allergen release. Basophil activation by ambient air extracts correlated better with airborne allergen than with pollen concentration. Although Bet v 1 is a mixture of different isoforms, its fingerprint is constant across Europe. Bet v 1 was also exclusively linked to pollen. Pollen from different days varied >10-fold in allergen release. Thus exposure to allergen is inaccurately monitored by only monitoring birch pollen grains. Indeed, a humanized basophil activation test correlated much better with allergen concentrations in ambient air than with pollen count. Monitoring the allergens themselves together with pollen in ambient air might be an improvement in allergen exposure assessment.
Release of Bet v 1 from birch pollen from 5 European countries. Results from the HIALINE study
NASA Astrophysics Data System (ADS)
The HIALINE working Group; Buters, Jeroen T. M.; Thibaudon, Michel; Smith, Matt; Kennedy, Roy; Rantio-Lehtimäki, Auli; Albertini, Roberto; Reese, Gerald; Weber, Bernhard; Galan, Carmen; Brandao, Rui; Antunes, Celia M.; Jäger, Siegfried; Berger, Uwe; Celenk, Sevcan; Grewling, Łukasz; Jackowiak, Bogdan; Sauliene, Ingrida; Weichenmeier, Ingrid; Pusch, Gudrun; Sarioglu, Hakan; Ueffing, Marius; Behrendt, Heidrun; Prank, Marje; Sofiev, Mikhail; Cecchi, Lorenzo
2012-08-01
Exposure to allergens is pivotal in determining sensitization and allergic symptoms in individuals. Pollen grain counts in ambient air have traditionally been assessed to estimate airborne allergen exposure. However, the exact allergen content of ambient air is unknown. We therefore monitored atmospheric concentrations of birch pollen grains and the matched major birch pollen allergen Bet v 1 simultaneously across Europe within the EU-funded project HIALINE (Health Impacts of Airborne Allergen Information Network).Pollen count was assessed with Hirst type pollen traps at 10 l min-1 at sites in France, United Kingdom, Germany, Italy and Finland. Allergen concentrations in ambient air were sampled at 800 l min-1 with a Chemvol® high-volume cascade impactor equipped with stages PM > 10 μm, 10 μm > PM > 2.5 μm, and in Germany also 2.5 μm > PM > 0.12 μm. The major birch pollen allergen Bet v 1 was determined with an allergen specific ELISA. Bet v 1 isoform patterns were analyzed by 2D-SDS-PAGE blots and mass spectrometric identification. Basophil activation was tested in an FcɛR1-humanized rat basophil cell line passively sensitized with serum of a birch pollen symptomatic patient.Compared to 10 previous years, 2009 was a representative birch pollen season for all stations. About 90% of the allergen was found in the PM > 10 μm fraction at all stations. Bet v 1 isoforms pattern did not vary substantially neither during ripening of pollen nor between different geographical locations. The average European allergen release from birch pollen was 3.2 pg Bet v 1/pollen and did not vary much between the European countries. However, in all countries a >10-fold difference in daily allergen release per pollen was measured which could be explained by long-range transport of pollen with a deviating allergen release. Basophil activation by ambient air extracts correlated better with airborne allergen than with pollen concentration.Although Bet v 1 is a mixture of different isoforms, its fingerprint is constant across Europe. Bet v 1 was also exclusively linked to pollen. Pollen from different days varied >10-fold in allergen release. Thus exposure to allergen is inaccurately monitored by only monitoring birch pollen grains. Indeed, a humanized basophil activation test correlated much better with allergen concentrations in ambient air than with pollen count. Monitoring the allergens themselves together with pollen in ambient air might be an improvement in allergen exposure assessment.
Gaidajis, George
2003-01-01
To assess ambient air quality at the wider area of TVX Hellas mining facilities, the Total Suspended Particulate matter (TSP) and its content in characteristic elements, i.e., As, Cd, Cu, Fe, Mn, Pb, Zn are being monitored for more than thirty months as part of the established Environmental Monitoring Program. High Volume air samplers equipped with Tissue Quartz filters were employed for the collection of TSP. Analyses were effected after digestion of the suspended particulate with an HNO3-HCl solution and determination of elemental concentrations with an Atomic Absorption Spectroscopy equipped with graphite furnace. The sampling stations were selected to record representatively the existing ambient air quality in the vicinity of the facilities and at remote sites not affected from industrial activities. Monitoring data indicated that the background TSP concentrations ranged from 5-60 microg/m3. Recorded TSP concentrations at the residential sites close to the facilities ranged between 20-100 microg/m3, indicating only a minimal influence from the mining and milling activities. Similar spatial variation was observed for the TSP constituents and specifically for Pb and Zn. To validate the monitoring procedures, a parallel sampling campaign took place with different High Volume samplers at days where low TSP concentrations were expected. The satisfactory agreement (+/- 11%) at low concentrations (50-100 microg/m3) clearly supported the reproducibility of the techniques employed specifically at the critical range of lower concentrations.
A mobile device system for early warning of ECG anomalies.
Szczepański, Adam; Saeed, Khalid
2014-06-20
With the rapid increase in computational power of mobile devices the amount of ambient intelligence-based smart environment systems has increased greatly in recent years. A proposition of such a solution is described in this paper, namely real time monitoring of an electrocardiogram (ECG) signal during everyday activities for identification of life threatening situations. The paper, being both research and review, describes previous work of the authors, current state of the art in the context of the authors' work and the proposed aforementioned system. Although parts of the solution were described in earlier publications of the authors, the whole concept is presented completely for the first time along with the prototype implementation on mobile device-a Windows 8 tablet with Modern UI. The system has three main purposes. The first goal is the detection of sudden rapid cardiac malfunctions and informing the people in the patient's surroundings, family and friends and the nearest emergency station about the deteriorating health of the monitored person. The second goal is a monitoring of ECG signals under non-clinical conditions to detect anomalies that are typically not found during diagnostic tests. The third goal is to register and analyze repeatable, long-term disturbances in the regular signal and finding their patterns.
ENVIRONMENTAL MONITORING AT GROUND ZERO AND LOWER MANHATTAN FOLLOWING THE COLLAPSE OF THE WTC
The U.S. EPA National Exposure Research Laboratory (NERL), in conjunction with our Regional offices, established a network of air monitoring sites to characterize ambient air concentrations of gases and particles in lower Manhattan following the collapse of the World Trade Cent...
This study evaluates performance of nitrogen dioxide NO2 and volatile organic compounds (VOC) passive samplers with corresponding reference monitors at two sites in the Detroit, Michigan area during the summer of 2005.
40 CFR 52.70 - Identification of plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... nonattainment areas submitted by the Governor of Alaska on January 18, 1980 as follows: Volume II. Analysis of...: Volume II. Analysis of Problems, Control Actions Section V. Ambient Air Monitoring A. Purpose C. Air Monitoring Network E. Annual Review (9) Provisions of a State Air Quality Control Plan submitted by the...
40 CFR 52.70 - Identification of plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... nonattainment areas submitted by the Governor of Alaska on January 18, 1980 as follows: Volume II. Analysis of...: Volume II. Analysis of Problems, Control Actions Section V. Ambient Air Monitoring A. Purpose C. Air Monitoring Network E. Annual Review (9) Provisions of a State Air Quality Control Plan submitted by the...
77 FR 20217 - Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and Sulfur
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-03
... Planning and Standards (OAQPS), U.S. Environmental Protection Agency, Mail Code C504-06, Research Triangle... of Research 3. Implementation Challenges 4. Monitoring Plan Development and Stakeholder Participation B. Summary of Proposed Evaluation of Monitoring Methods C. Comments on Field Pilot Program and...
A 17-day pilot study investigating potential PM exposures of an elderly population was conducted near Baltimore, Maryland. Collection of residential indoor, residential outdoor, and ambient monitoring data associated with the subjects living at a common retirement facility was...
The Mercury Monitoring Workshop was developed because mercury contamination, both nationally and internationally, has long been recognized as a growing problem for both humans and ecosystems. Mercury is released to the environment from a variety of human (anthropogenic) sources i...
Relationship Between PM2.5 Collected at Residential Outdoor Locations and a Central Site
Regression models are developed to describe the relationship between ambient PM2.5 (particulate matter [PM] ≤ 2.5 μm in aerodynamic diameter) mass concentrations measured at a central-site monitor with those at residential outdoor monitors. Understanding the...
NRC TLD Direct Radiation Monitoring Network. Progress report, October--December 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
Struckmeyer, R.
This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1996. It provides the ambient radiation levels measured in the vicinity of 74 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 3 figs., 4 tabs.
Code of Federal Regulations, 2012 CFR
2012-07-01
... scale. For example, according to Figure E-1 of this appendix, if a PM sampler is primarily influenced by... criterion is designed to avoid undue influences from minor sources. 7 For microscale CO monitoring sites in... Research Board, Washington, DC. January 1978.) 4. Pace, T.G., W.P. Freas, and E.M. Afify. Quantification of...
NASA Astrophysics Data System (ADS)
Colombero, C.; Baillet, L.; Comina, C.; Jongmans, D.; Larose, E.; Valentin, J.; Vinciguerra, S.
2018-06-01
Monitoring the temporal evolution of resonance frequencies and velocity changes detected from ambient seismic noise recordings can help in recognizing reversible and irreversible modifications within unstable rock volumes. With this aim, the long-term ambient seismic noise data set acquired at the potentially unstable cliff of Madonna delSasso (NW Italian Alps) was analysed in this study, using both spectral analysis and cross-correlation techniques. Noise results were integrated and compared with direct displacement measurements and meteorological data, to understand the long-term evolution of the cliff. No irreversible modifications in the stability of the site were detected over the monitored period. Conversely, daily and seasonal air temperature fluctuations were found to control resonance frequency values, amplitudes and directivities and to induce reversible velocity changes within the fractured rock mass. The immediate modification in the noise parameters due to temperature fluctuations was interpreted as the result of rock mass thermal expansion and contraction, inducing variations in the contact stiffness along the fractures isolating two unstable compartments. Differences with previous case studies were highlighted in the long-term evolution of noise spectral amplitudes and directivities, due to the complex 3-D fracture setting of the site and to the combined effects of the two unstable compartments.
Applicability of ambient toxicity testing to national or regional water-quality assessment
Elder, John F.
1990-01-01
Comprehensive assessment of the quality of natural waters requires a multifaceted approach. Descriptions of existing conditions may be achieved by various kinds of chemical and hydrologic analyses, whereas information about the effects of such conditions on living organisms depends on biological monitoring. Toxicity testing is one type of biological monitoring that can be used to identify possible effects of toxic contaminants. Based on experimentation designed to monitor responses of organisms to environmental stresses, toxicity testing may have diverse purposes in water-quality assessments. These purposes may include identification of areas that warrant further study because of poor water quality or unusual ecological features, verification of other types of monitoring, or assessment of contaminant effects on aquatic communities. Toxicity-test results are most effective when used as a complement to chemical analyses, hydrologic measurements, and other biological monitoring. However, all toxicity-testing procedures have certain limitations that must be considered in developing the methodology and applications of toxicity testing in any large-scale water-quality-assessment program. A wide variety of toxicity-test methods have been developed to fulfill the needs of diverse applications. The methods differ primarily in the selections made relative to four characteristics: (1) test species, (2) endpoint (acute or chronic), (3) test-enclosure type, and (4) test substance (toxicant) that functions as the environmental stress. Toxicity-test approaches vary in their capacity to meet the needs of large-scale assessments of existing water quality. Ambient testing, whereby the test organism is exposed to naturally occurring substances that contain toxicant mixtures in an organic or inorganic matrix, is more likely to meet these needs than are procedures that call for exposure of the test organisms to known concentrations of a single toxicant. However, meaningful interpretation of ambient test results depends on the existence of accompanying chemical analysis of the ambient media. The ambient test substance may be water or sediments. Sediment tests have had limited application, but they are useful because most toxicants tend to accumulate in sediments and many test species either inhabit the sediments or are in frequent contact with them. Biochemical testing methods, which have been developing rapidly in recent years, are likely to be among the most useful procedures for large-scale water-quality assessments. They are relatively rapid and simple, and more. importantly, they focus on biochemical changes that are the initial responses of virtually all organisms to environmental stimuli. Most species are sensitive to relatively few toxicants, and their sensitivities vary as conditions change. Therefore, each test method has particular uses and limitations, and no single test has universal applicability. One of the most informative approaches to toxicity testing is to combine biochemical tests with other test methods in a 'battery of tests' that is diversified enough to characterize different types of toxicants and different trophic levels. However, such an approach can be costly, and if not carefully designed, it may not yield enough additional information to warrant the additional cost. The application of toxicity tests to large-scale water-quality assessments is hampered by a number of difficulties. Toxicity tests often are not sensitive enough to enable detection of most contaminant problems in the natural environment. Furthermore, because sensitivities among different species and test conditions can be highly variable, conclusions about the toxicant problems of an ecosystem are strongly dependent on the test procedure used. In addition, the experimental systems used in toxicity tests cannot replicate the complexity or variability of natural conditions, and positive test results cannot identify the source or nature of
Hot dogs: High ambient temperatures impact reproductive success in a tropical carnivore.
Woodroffe, Rosie; Groom, Rosemary; McNutt, J Weldon
2017-10-01
Climate change imposes an urgent need to recognise and conserve the species likely to be worst affected. However, while ecologists have mostly explored indirect effects of rising ambient temperatures on temperate and polar species, physiologists have predicted direct impacts on tropical species. The African wild dog (Lycaon pictus), a tropical species, exhibits few of the traits typically used to predict climate change vulnerability. Nevertheless, we predicted that wild dog populations might be sensitive to weather conditions, because the species shows strongly seasonal reproduction across most of its geographical range. We explored associations between weather conditions, reproductive costs, and reproductive success, drawing on long-term wild dog monitoring data from sites in Botswana (20°S, 24 years), Kenya (0°N, 12 years), and Zimbabwe (20°S, 6 years). High ambient temperatures were associated with reduced foraging time, especially during the energetically costly pup-rearing period. Across all three sites, packs which reared pups at high ambient temperatures produced fewer recruits than did those rearing pups in cooler weather; at the non-seasonal Kenya site such packs also had longer inter-birth intervals. Over time, rising ambient temperatures at the (longest-monitored) Botswana site coincided with falling wild dog recruitment. Our findings suggest a direct impact of high ambient temperatures on African wild dog demography, indicating that this species, which is already globally endangered, may be highly vulnerable to climate change. This vulnerability would have been missed by simplistic trait-based assessments, highlighting the limitations of such assessments. Seasonal reproduction, which is less common at low latitudes than at higher latitudes, might be a useful indicator of climate change vulnerability among tropical species. © 2017 The Authors. Journal of Animal Ecology © 2017 British Ecological Society.
Continuous monitoring of high-rise buildings using seismic interferometry
NASA Astrophysics Data System (ADS)
Mordret, A.; Sun, H.; Prieto, G. A.; Toksoz, M. N.; Buyukozturk, O.
2016-12-01
The linear seismic response of a building is commonly extracted from ambient vibration measurements. Seismic deconvolution interferometry performed on ambient vibration measurements can also be used to estimate the dynamic characteristics of a building, such as the velocity of shear-waves travelling inside the building as well as a damping parameter depending on the intrinsic attenuation of the building and the soil-structure coupling. The continuous nature of the ambient vibrations allows us to measure these parameters repeatedly and to observe their temporal variations. We used 2 weeks of ambient vibration recorded by 36 accelerometers installed in the Green Building on the Massachusetts Institute of Technology campus (Cambridge, MA) to continuously monitor the shear-wave speed and the attenuation factor of the building. Due to the low strain of the ambient vibrations, the observed changes are totally reversible. The relative velocity changes between a reference deconvolution function and the current deconvolution functions are measured with two different methods: 1) the Moving Window Cross-Spectral technique and 2) the stretching technique. Both methods show similar results. We show that measuring the stretching coefficient for the deconvolution functions filtered around the fundamental mode frequency is equivalent to measuring the wandering of the fundamental frequency in the raw ambient vibration data. By comparing these results with local weather parameters, we show that the relative air humidity is the factor dominating the relative seismic velocity variations in the Green Building, as well as the wandering of the fundamental mode. The one-day periodic variations are affected by both the temperature and the humidity. The attenuation factor, measured as the exponential decay of the fundamental mode waveforms, shows a more complex behaviour with respect to the weather measurements.
Real-time monitoring of BTEX in air via ambient-pressure MPI
NASA Astrophysics Data System (ADS)
Swenson, Orven F.; Carriere, Josef P.; Isensee, Harlan; Gillispie, Gregory D.; Cooper, William F.; Dvorak, Michael A.
1998-05-01
We have developed and begun to field test a very sensitive method for real-time measurements of single-ring aromatic hydrocarbons in ambient air. In this study, we focus on the efficient 1 + 1 resonance enhanced multiphoton ionization (REMPI) of the BTEX species in the narrow region between 266 and 267 nm. We particularly emphasize 266.7 nm, a wavelength at which both benzene and toluene exhibit a sharp absorbance feature and benzene and its alkylated derivatives all absorb. An optical parametric oscillator system generating 266.7 nm, a REMPI cell, and digital oscilloscope detector are mounted on a breadboard attached to a small cart. In the first field test, the cart was wheeled through the various rooms of a chemistry research complex. Leakage of fuel through the gas caps of cars and light trucks in a parking lot was the subject of the second field test. The same apparatus was also used for a study in which the performance of the REMPI detector and a conventional photoionization detector were compared as a BTEX mixture was eluted by gas chromatography. Among the potential applications of the methodology are on-site analysis of combustion and manufacturing processes, soil gas and water headspace monitoring, space cabin and building air quality, and fuel leak detection.
TOWARDS A NOVEL MODULAR ARCHITECTURE FOR CERN RADIATION MONITORING.
Boukabache, Hamza; Pangallo, Michel; Ducos, Gael; Cardines, Nicola; Bellotta, Antonio; Toner, Ciarán; Perrin, Daniel; Forkel-Wirth, Doris
2017-04-01
The European Organization for Nuclear Research (CERN) has the legal obligation to protect the public and the people working on its premises from any unjustified exposure to ionising radiation. In this context, radiation monitoring is one of the main concerns of the Radiation Protection Group. After 30 y of reliable service, the ARea CONtroller (ARCON) system is approaching the end of its lifecycle, which raises the need for new, more efficient radiation monitors with a high level of modularity to ensure better maintainability. Based on these two main principles, new detectors are currently being developed that will be capable of measuring very low dose rates down to 50 nSv h-1, whilst being able to measure radiation over an extensive range of 8 decades without any auto scaling. To reach these performances, CERN Radiation MOnitoring Electronics (CROME), the new generation of CERN radiation monitors, is based on the versatile architecture that includes new read-out electronics developed by the Instrumentation and Logistics section of the CERN Radiation Protection Group as well as a reconfigurable system on chip capable of performing complex processing calculations. Beside the capabilities of CROME to continuously measure the ambient dose rate, the system generates radiation alarms, provides interlock signals, drives alarm display units through a fieldbus and provides long-term, permanent and reliable data logging. The measurement tests performed during the first phase of the development show very promising results that pave the way to the second phase: the certification. © The Author 2016. Published by Oxford University Press.
TOWARDS A NOVEL MODULAR ARCHITECTURE FOR CERN RADIATION MONITORING
Boukabache, Hamza; Pangallo, Michel; Ducos, Gael; Cardines, Nicola; Bellotta, Antonio; Toner, Ciarán; Perrin, Daniel; Forkel-Wirth, Doris
2017-01-01
Abstract The European Organization for Nuclear Research (CERN) has the legal obligation to protect the public and the people working on its premises from any unjustified exposure to ionising radiation. In this context, radiation monitoring is one of the main concerns of the Radiation Protection Group. After 30 y of reliable service, the ARea CONtroller (ARCON) system is approaching the end of its lifecycle, which raises the need for new, more efficient radiation monitors with a high level of modularity to ensure better maintainability. Based on these two main principles, new detectors are currently being developed that will be capable of measuring very low dose rates down to 50 nSv h−1, whilst being able to measure radiation over an extensive range of 8 decades without any auto scaling. To reach these performances, CERN Radiation MOnitoring Electronics (CROME), the new generation of CERN radiation monitors, is based on the versatile architecture that includes new read-out electronics developed by the Instrumentation and Logistics section of the CERN Radiation Protection Group as well as a reconfigurable system on chip capable of performing complex processing calculations. Beside the capabilities of CROME to continuously measure the ambient dose rate, the system generates radiation alarms, provides interlock signals, drives alarm display units through a fieldbus and provides long-term, permanent and reliable data logging. The measurement tests performed during the first phase of the development show very promising results that pave the way to the second phase: the certification. PMID:27909154
Haiganoush K. Preisler; Shiyuan (Sharon) Zhong; Annie Esperanza; Timothy J. Brown; Andrzej Bytnerowicz; Leland Tarnay
2010-01-01
Data from four continuous ozone and weather monitoring sites operated by the National Park Service in Sierra Nevada, California, are used to develop an ozone forecasting model and to estimate the contribution of wildland fires on ambient ozone levels. The analyses of weather and ozone data pointed to the transport of ozone precursors from the Central Valley as an...