Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-14
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,156] American Spring Wire... workers and former workers of American Spring Wire Corporation, Kankakee, Illinois (subject firm) to apply... production of spring wire. The worker group does not include leased workers. New information obtained during...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-25
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,156] American Spring Wire Corporation, Kankakee, IL; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated August 24, 2010, workers requested administrative reconsideration of the negative...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-09
... Wire Strand from Mexico: Rescission of Antidumping Duty Administrative Review AGENCY: Import... request an administrative review of the antidumping duty order on prestressed concrete steel wire strand... received a timely request from American Spring Wire Corp., Insteel Wire Products Co., and Sumiden Wire...
Physical, mechanical, and flexural properties of 3 orthodontic wires: an in-vitro study.
Juvvadi, Shubhaker Rao; Kailasam, Vignesh; Padmanabhan, Sridevi; Chitharanjan, Arun B
2010-11-01
Understanding the biologic requirements of orthodontic patients requires proper characterization studies of new archwire alloys. The aims of this study were to evaluate properties of wires made of 2 new materials and to compare their properties with those of stainless steel. The sample consisted of 30 straight lengths of 3 types of wires: stainless steel, titanium-molybdenum alloy, and beta-titanium alloy. Eight properties were evaluated: wire dimension, edge bevel, composition, surface characteristics, frictional characteristics, ultimate tensile strength (UTS), modulus of elasticity (E), yield strength (YS), and load deflection characteristics. A toolmaker's microscope was used to measure the edge bevel, and x-ray fluorescence was used for composition analysis. Surface profilometry and scanning electron microscopy were used for surface evaluation. A universal testing machine was used to evaluate frictional characteristics, tensile strength, and 3-point bending. Stainless steel was the smoothest wire; it had the lowest friction and spring-back values and high values for stiffness, E, YS, and UTS. The titanium-molybdenum alloy was the roughest wire; it had high friction and intermediate spring-back, stiffness, and UTS values. The beta-titanium alloy was intermediate for smoothness, friction, and UTS but had the highest spring-back. The beta-titanium alloy with increased UTS and YS had a low E value, suggesting that it would have greater resistance to fracture, thereby overcoming a major disadvantage of titanium-molybdenum alloy wires. The beta-titanium alloy wire would also deliver gentler forces. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Spring control of wire harness loops
NASA Technical Reports Server (NTRS)
Curcio, P. J.
1979-01-01
Negator spring control guides wire harness between movable and fixed structure. It prevents electrical wire harness loop from jamming or being severed as wire moves in response to changes in position of aircraft rudder. Spring-loaded coiled cable controls wire loop regardless of rudder movement.
Heat Setting Procedures for Helical Coiled Springs
1976-12-01
Springs, M -aw-Hill Book Company, Inc., New York, New York, 1963. 1 - 1i) Music Wire, QQ-9-JM7 •r ’Wire diameter = 0.043 iALCh Stress relieve: Heat at... music wire and chrome vanadium materials c) 100,000 psi corresponds to 1.580 inches b) 150,0O0 psi corresponds to 1.020 inches For stainless steel...frequency which would produce spring set with the minimun amount of sprirg breakage. It was determined that the music wire springs should be cycled
Suzuki, Akihiro; Kanetaka, Hiroyasu; Shimizu, Yoshinaka; Tomizuka, Ryo; Hosoda, Hideki; Miyazaki, Shuichi; Okuno, Osamu; Igarashi, Kaoru; Mitani, Hideo
2006-11-01
To examine the mechanical properties and the usefulness of titanium-niobium-aluminum (Ti-Nb-Al) wire in orthodontic tooth movement as compared with nickel-titanium (Ni-Ti) wire. The load deflection of expansion springs was gauged with an original jig. The gradient of the superelastic region was measured during the unloading process. Expansion springs comprising the two types of alloy wires were applied to upper first molars of rats. The distance between the first molars was measured with micrometer calipers. The force magnitude of the Ti-Nb-Al expansion spring was lower than that of the Ni-Ti expansion spring over the entire deflection range. The initial force magnitude and the gradient in the superelastic region of the Ti-Nb-Al expansion springs were half those of the Ni-Ti expansion springs. Thus, Ti-Nb-Al expansion springs generated lighter and more continuous force. Tooth movement in the Ni-Ti group proceeded in a stepwise fashion. On the other hand, tooth movement in the Ti-Nb-Al group showed relatively smooth and continuous progression. At 17 days after insertion of expansion springs, there were no significant differences between the Ti-Nb-Al and Ni-Ti groups in the amount of tooth movement. These results indicate that Ti-Nb-Al wire has excellent mechanical properties for smooth, continuous tooth movement and suggest that Ti-Nb-Al wire may be used as a practical nickel-free shape memory and superelastic alloy wire for orthodontic treatment as a substitute for Ni-Ti wire.
Ferreira, M do A
1999-03-01
The mechanical behavior of orthodontics closing loops, with three different wire materials (stainless steel, cobalt-chromium and titanium-molybdenum) and with different cross-sections and a double delta design, was studied in tension tests. The springs were stress-relieved, except the titanium-molybdenum wires. There were 72 sample springs, divided into 33 stainless steel, 26 cobalt-chromium and 13 titanium-molybdenum, activated at 0.5 mm intervals, from neutral position to 3.0 mm. It was hypothesized that loads, after spring activation, and spring rate, are dependent on cross-section, wire material, and activation. The analysis of variance and the Tukey-Kramer test were applied to verify the differences between all coupled averages of the loads. Regression analysis was also used to verify if closing loops behavior was in accordance with Hooke's law and to obtain the spring rate. The results show that the loads are dependent on activation, cross-section, and wire material. Titanium-molybdenum 0.017 x 0.025 inch (Ormco) springs showed the smallest loads and the best spring rate. (beta = 84.9 g/mm)
Metal Oxide Silicon /MOS/ transistors protected from destructive damage by wire
NASA Technical Reports Server (NTRS)
Deboo, G. J.; Devine, E. J.
1966-01-01
Loop of flexible, small diameter, nickel wire protects metal oxide silicon /MOS/ transistors from a damaging electrostatic potential. The wire is attached to a music-wire spring, slipped over the MOS transistor case, and released so the spring tensions the wire loop around all the transistor leads, shorting them together. This allows handling without danger of damage.
Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel
Salehi, Anahita; Asatourian, Armen
2017-01-01
Background Titanium-molybdenum alloy (TMA) and stainless steel (SS) wires are commonly used in orthodontics as arch-wires for tooth movement. However, plastic deformation phenomenon in these arch-wires seems to be a major concern among orthodontists. This study aimed to compare the mechanical properties of TMA and SS wires with different dimensions. Material and Methods Seventy-two wire samples (36 TMA and 36 SS) of three different sizes (19×25, 17×25 and 16×22) were analyzed in vitro, with 12 samples in each group. Various mechanical properties of the wires, including spring-back, bending moment and stiffness were determined using a universal testing machine. Student’s t-test showed statistically significant differences in the mean values of all the groups. In addition, metallographic comparison of SS and TMA wires was conducted under an optical microscope. Results The degree of stiffness of 16×22-sized SS and TMA springs was found to be 12±2 and 5±0.4, respectively, while the bending moment was estimated to be 1927±352 (gm-mm) and 932±16 (gm-mm), respectively; the spring-back index was determined to be 0.61±0.2 and 0.4±.09, respectively (p<0.001). There were no statistically significant differences in spring-back index in larger dimensions of the wires. Conclusions Systematic analysis indicated that springs made of TMA were superior compared to those made of SS. Although both from economic and functionality viewpoints the use of TMA is suggested, further clinical investigations are recommended. Key words:Bending moment, optical microscope, spring-back, stainless steel, stiffness, titanium‒molybdenum alloy. PMID:28149469
A two-way architectural actuator using NiTi SE wire and SME spring
NASA Astrophysics Data System (ADS)
Nematollahi, Mohammadreza; Mehrabi, Reza; Callejas, Miguel A.; Elahinia, Hedyeh; Elahinia, Mohammad
2018-03-01
This paper presents a bio-inspired continuously adapting architectural element, to enable a smart canopy that provides shade to buildings that need protection from sunlight. The smart actuator consists of two elements: one NiTi shape memory (SME) spring and one NiTi superelastic (SE) wire. The SE wire is deformed to a `U' shape and then the SME spring is attached to it. Due to the force of SE wire exerted on SME spring, the smart canopy is in its open position. When the environment's temperature increases, the actuator activates and shrinks the SME spring and hence it closes the canopy. In continues, when the temperature decreases at evening, the actuator inactive and SE wire will open the smart fabric. This unique activation provides different advantages like silent actuation, maintenance free, eco-friendly, and no or low energy consumption. Here, the conceptual design of the smart canopy actuator will be discussed. Then, a simulation study, using finite element method, is used to investigate components' behavior. The extracted material parameters are implemented in the subroutine, to simulate the behavior of the shape memory alloy elements. Simulation's results predict superelastic behavior for the SE wire and shape memory effect for the NiTi spring. For further studies, a prototype will be fabricated to confirm simulation's results, as well as performing some experimental tests.
Sivaraj, Aravind
2013-01-01
Background: Application of light and continuous forces for optimum physiological response and least damage to the tooth supporting structures should be the primary aim of the orthodontist. Nickel titanium alloys with the properties of excellent spring back, super elasticity and wide range of action is one of the natural choices for the clinicians to achieve this goal. In recent periods, various wire manufacturers have come with a variety of wires exhibiting different properties. It is the duty of the clinician to select appropriate wires during various stages of treatment for excellent results. For achieving this evaluation of the properties of these wires is essential. Materials & Methods: This study is focussed on evaluating the super elastic property of eight groups of austenite active nickel titanium wires. Eight groups of archwires bought from eight different manufacturers were studied. These wires were tested through mechanical tensile testing and electrical resistivity methods. Results: Unloading curves were carefully assessed for superelastic behaviour on deactivation. Rankings of the wires tested were based primarily upon the unloading curve’s slope Conclusion: Ortho organisers wires ranked first and superior, followed by American Orthodontics and Ormco A wires. Morelli and GAClowland NiTi wires were ranked last. It can be concluded that the performance of these wires based on rankings should be further evaluated by clinical studies. How to cite this article: Sivaraj A. Comparison of Superelasticity of Nickel Titanium Orthodontic Arch wires using Mechanical Tensile Testing and Correlating with Electrical Resistivity. J Int Oral Health 2013; 5(3):1-12. PMID:24155596
Inside the Wire: American Security and Cyber Warfare
2017-03-01
Baumbauer, Derek E. "Ghost in the Network." University Of Pennsylvania Law Review 162, no. 5(April 2014): 1011-91. Daniali, Ghorban. "E- Money Laundering ...Challenges, Shared Opportunities." Strategic Studies Quarterly 6, no. 1(Spring 2012): 3-8. Cser, Orsolya. "The Role and Security of Money From the...34 Journal of National Security Law & Policy 7, no. 1(February 2014): 115-38. Cser, Orsolya. "The Role and Security of Money From the Aspect of Cyber
75 FR 36678 - Prestressed Concrete Steel Wire Strand From China; Determinations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-28
... Concrete Steel Wire Strand From China; Determinations On the basis of the record \\1\\ developed in the... prestressed concrete steel wire strand (PC strand), provided for in subheading 7312.10.30 of the Harmonized... Spring Wire Corp. (Bedford Heights, OH); Insteel Wire Products Co. (Mt. Airy, NC); and Sumiden Wire...
NASA Astrophysics Data System (ADS)
Gurung, H.; Banerjee, A.
2016-02-01
This report presents the development of an extended Kalman filter (EKF) to harness the self-sensing capability of a shape memory alloy (SMA) wire, actuating a linear spring. The stress and temperature of the SMA wire, constituting the state of the system, are estimated using the EKF, from the measured change in electrical resistance (ER) of the SMA. The estimated stress is used to compute the change in length of the spring, eliminating the need for a displacement sensor. The system model used in the EKF comprises the heat balance equation and the constitutive relation of the SMA wire coupled with the force-displacement behavior of a spring. Both explicit and implicit approaches are adopted to evaluate the system model at each time-update step of the EKF. Next, in the measurement-update step, estimated states are updated based on the measured electrical resistance. It has been observed that for the same time step, the implicit approach consumes less computational time than the explicit method. To verify the implementation, EKF estimated states of the system are compared with those of an established model for different inputs to the SMA wire. An experimental setup is developed to measure the actual spring displacement and ER of the SMA, for any time-varying voltage applied to it. The process noise covariance is decided using a heuristic approach, whereas the measurement noise covariance is obtained experimentally. Finally, the EKF is used to estimate the spring displacement for a given input and the corresponding experimentally obtained ER of the SMA. The qualitative agreement between the EKF estimated displacement with that obtained experimentally reveals the true potential of this approach to harness the self-sensing capability of the SMA.
Correction of craniosynostosis using modified spring-assisted surgery.
Shen, Weimin; Cui, Jie; Chen, Jianbin; Zou, Jijun; Ji, Yi; Chen, Haini; Xiongzheng, Mu
2015-03-01
The use of springs in craniofacial surgery was originated at Sahlgrenska University Hospital in 1997 as a way of remodeling the cranial vault postoperatively. After a decade of development, spring technology has been improved to a greater extent. However, there still exist some problems, such as the poor consistency of steel wire stretches, the wrong position of steel wire, the problem of increasing the elasticity of springs, and so on. We have designed a spring device for external uses. This device is composed of 3 parts. The first part is the outside of the spring ring. This ring is the same as the internal spring, only a little bigger. The second part is a small U-shaped hook, which is made of titanium plates and linked to the skull portion. The U-shaped hook is approximately 1 cm long and 1 cm wide. The hang is approximately 1 cm long and 0.6 cm wide. The U-shaped level length is 1 cm, but the level width should be equal to or bigger than the thickness of the skull. The third part is a steel wire, which is placed at 1 end of hook. We first conduct a strip craniotomy, then put 2 hooks at the bone ends and, after that, fix hooks on the skull. Finally, we pull the steel wire of the hook end out of the scalp, connect it with the external spring, and draw out the external spring. We performed 24 craniofacial spring placement procedures for 12 patients with craniosynostosis. We used 6 springs for 3 patients who had anterior plagiocephaly, 12 springs for 6 patients who had scaphocephaly, and 3 springs for another patient who had metopic synostosis and holoprosencephaly. We also used 3 springs for 2 patients who had metopic synostosis. The 12 patients have not required further surgeries so far, and there were no major complications. Spring dislodgement had not caused any complication in early cases. We could easily change the position of the spring rings from outside the scalp, regularly correct the elasticity of the spring rings, and replace spring rings to increase the traction. The head shapes of the 12 children have been improved significantly to use external spring rings. This therapeutic modality in craniofacial surgery has allowed minimization of the extent of surgery without compromising clinical outcomes. The authors have shown that the use of external spring techniques is safe and, in selected situations, offer significant advantages over other methods of treatment. It makes up for a number of shortcomings of internal springs.
21 CFR 872.5410 - Orthodontic appliance and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., orthodontic metal bracket, orthodontic wire clamp, preformed orthodontic space maintainer, orthodontic expansion screw retainer, orthodontic spring, orthodontic tube, and orthodontic wire. (b) Classification...
21 CFR 872.5410 - Orthodontic appliance and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., orthodontic metal bracket, orthodontic wire clamp, preformed orthodontic space maintainer, orthodontic expansion screw retainer, orthodontic spring, orthodontic tube, and orthodontic wire. (b) Classification...
21 CFR 872.5410 - Orthodontic appliance and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., orthodontic metal bracket, orthodontic wire clamp, preformed orthodontic space maintainer, orthodontic expansion screw retainer, orthodontic spring, orthodontic tube, and orthodontic wire. (b) Classification...
21 CFR 872.5410 - Orthodontic appliance and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., orthodontic metal bracket, orthodontic wire clamp, preformed orthodontic space maintainer, orthodontic expansion screw retainer, orthodontic spring, orthodontic tube, and orthodontic wire. (b) Classification...
Nonharmonic oscillations of nanosized cantilevers due to quantum-size effects
NASA Astrophysics Data System (ADS)
Olsen, Martin; Gradin, Per; Lindefelt, Ulf; Olin, Håkan
2010-02-01
Using a one-dimensional jellium model and standard beam theory we calculate the spring constant of a vibrating nanowire cantilever. By using the asymptotic energy eigenvalues of the standing electron waves over the nanometer-sized cross-section area, the change in the grand canonical potential is calculated and hence the force and the spring constant. As the wire is bent more electron states fits in its cross section. This has an impact on the spring “constant” which oscillates slightly with the bending of the wire. In this way we obtain an amplitude-dependent resonance frequency of the oscillations that should be detectable.
Variable resistance constant tension and lubrication device. [using oil-saturated leather wiper
NASA Technical Reports Server (NTRS)
Smith, H. J. (Inventor)
1974-01-01
A variable resistance device is described which includes a cylindrical housing having elongated resistance wires. A movable arm having a supporting block carried on the outer end is rotatably carried by the cylindrical housing. An arcuate steel spring member is pivotally supported by the movable arm. A leather wiper member is carried adjacent to one end of the spring steel member, and an electrically conductive surface is carried adjacent to the other end. The supporting block maintains the spring steel member in compression so that a constant pressure is applied to the conductive end of the spring steel member and the leather wiper. The leather wiper is saturated with a lubricating oil for maintaining the resistance wire clean as the movable arm is manipulated.
Relationship between input power and power density of SMA spring
NASA Astrophysics Data System (ADS)
Park, Cheol Hoon; Ham, Sang Yong; Son, Young Su
2016-04-01
The important required characteristics of an artificial muscle for a human arm-like manipulator are high strain and high power density. From this viewpoint, an SMA (shape memory alloy) spring is a good candidate for the actuator of a robotic manipulator that utilizes an artificial muscle. In this study, the maximum power density of an SMA spring was evaluated with respect to the input power. The spring samples were fabricated from SMA wires of different diameters ranging between 0.1 and 0.3 mm. For each diameter, two types of wires with different transition temperatures were used. The relationship between the transition temperature and maximum power density was also evaluated. Each SMA spring was stretched downward by an attached weight and the temperature was increased through the application of an electric current. The displacement, velocity, and temperature of the SMA spring were measured by laser displacement sensors and a thermocouple. Based on the experimental data, it was determined that the maximum power densities of the different SMA springs ranged between 1,300 and 5,500 W/kg. This confirmed the applicability of an SMA spring to human arm-like robotic manipulators. The results of this study can be used as reference for design.
Applicability of Shape Memory Alloy Wire for an Active, Soft Orthotic
NASA Astrophysics Data System (ADS)
Stirling, Leia; Yu, Chih-Han; Miller, Jason; Hawkes, Elliot; Wood, Robert; Goldfield, Eugene; Nagpal, Radhika
2011-07-01
Current treatments for gait pathologies associated with neuromuscular disorders may employ a passive, rigid brace. While these provide certain benefits, they can also cause muscle atrophy. In this study, we examined NiTi shape memory alloy (SMA) wires that were annealed into springs to develop an active, soft orthotic (ASO) for the knee. Actively controlled SMA springs may provide variable assistances depending on factors such as when, during the gait cycle, the springs are activated; ongoing muscle activity level; and needs of the wearer. Unlike a passive brace, an active orthotic may provide individualized control, assisting the muscles so that they may be used more appropriately, and possibly leading to a re-education of the neuro-motor system and eventual independence from the orthotic system. A prototype was tested on a suspended, robotic leg to simulate the swing phase of a typical gait. The total deflection generated by the orthotic depended on the knee angle and the total number of actuators triggered, with a max deflection of 35°. While SMA wires have a high energy density, they require a significant amount of power. Furthermore, the loaded SMA spring response times were much longer than the natural frequency of an average gait for the power conditions tested. While the SMA wires are not appropriate for correction of gait pathologies as currently implemented, the ability to have a soft, actuated material could be appropriate for slower timescale applications.
The 80 kV electrostatic wire septum for AmPS
NASA Astrophysics Data System (ADS)
Vanderlinden, A.; Bijleveld, J. H. M.; Rookhuizen, H. Boer; Bruinsma, P. J. T.; Heine, E.; Lassing, P.; Prins, E.
The characteristics of the wire septum for the Amsterdam Pulse Stretcher (AmPS) are summarized. In the extraction process of the AmPS the extracted beam is intercepted from the circulating beam by the 1 m long electrostatic wire septum. For a bending angle of 4.4 mrad, the maximum anode voltage is 80 kV. The system developed consists of a wire spacing of 0.65 mm between tungsten wires of 50 micrometers diameter. Stainless steel spring wires, bent in a half cylindrical carrier, stretch the septum wires two by two. Prototype tests were successful up to an anode voltage of 120 kV.
Fabrication and modeling of shape memory alloy springs
NASA Astrophysics Data System (ADS)
Heidari, B.; Kadkhodaei, M.; Barati, M.; Karimzadeh, F.
2016-12-01
In this paper, shape memory alloy (SMA) helical springs are produced by shape setting two sets of NiTi (Ti-55.87 at% Ni) wires, one of which showing shape memory effect and another one showing pseudoelasticity at the ambient temperature. Different pitches as well as annealing temperatures are tried to investigate the effect of such parameters on the thermomechanical characteristics of the fabricated springs. Phase transformation temperatures of the products are measured by differential scanning calorimetry and are compared with those of the original wires. Compression tests are also carried out, and stiffness of each spring is determined. The desired pitches are so that a group of springs experiences phase transition during loading while the other does not. The former shows a varying stiffness upon the application of compression, but the latter acts as passive springs with a predetermined stiffness. Based on the von-Mises effective stress and strain, an enhanced one-dimensional constitutive model is further proposed to describe the shear stress-strain response within the coils of an SMA spring. The theoretically predicted force-displacement responses of the produced springs are shown to be in a reasonable agreement with the experimental results. Finally, effects of variations in geometric parameters on the axial force-displacement response of an SMA spring are investigated.
Metering Wheel-Wire Track Wire Boom Deployment Mechanism
NASA Technical Reports Server (NTRS)
Granoff, Mark S.
2014-01-01
The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.
Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study
Rakhshan, Vahid; Pousti, Maryam; Rahimi, Hajir; Shariati, Mahsa; Aghamohamadi, Bahareh
2012-01-01
Objective The purpose of this study was to evaluate the surface roughness (SR) of 2 types of orthodontic archwires made by 4 different manufacturers. Methods This in vitro experimental study was conducted on 35 specimens of 7 different orthodontic archwires, namely, 1 nickel-titanium (NiTi) archwire each from the manufacturers American Orthodontics, OrthoTechnology, All-Star Orthodontics, and Smart Technology, and 1 stainless steel (SS) archwire each from the manufacturers American Orthodontics, OrthoTechnology, and All-Star Orthodontics. After analyzing the composition of each wire by energy-dispersive X-ray analysis, the SR of each wire was determined by scanning electron microscopy (SEM) and surface profilometry. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (α < 0.05). Results The average SR of NiTi wires manufactured by Smart Technology, American Orthodontics, OrthoTechnology, and All-Star Orthodontics were 1,289 ± 915 A°, 1,378 ± 372 A°, 2,444 ± 369 A°, and 5,242 ± 2,832 A°, respectively. The average SR of SS wires manufactured by All-Star Orthodontics, OrthoTechnology, and American Orthodontics were 710 ± 210 A°, 1,831 ± 1,156 A°, and 4,018 ± 2,214 A°, respectively. Similar to the results of profilometry, the SEM images showed more defects and cracks on the SS wire made by American Orthodontics and the NiTi wire made by All-Star Orthodontics than others. Conclusions The NiTi wire manufactured by All-Star Orthodontics and the SS wire made by American Orthodontics were the roughest wires. PMID:23112943
Design of a constant tension thermocouple rake suitable for flame studies
NASA Technical Reports Server (NTRS)
Ahuja, Sandeep; Miller, David L.
1993-01-01
An improved, spring-loaded thermocouple rake, suitable for studying flame structure, has been designed. This design keeps the thermocouple under tension thereby ensuring that the thermocouple does not droop due to the thermal expansion of the sensing wire when inserted in the flame. The present design allows the usage of thermocouple wire as small as 0.0508 mm and relative ease in changing thermocouple wire.
NASA Technical Reports Server (NTRS)
Granett, D.
1985-01-01
Steadying screws with fingers unnecessary. Crimp in uncompressed spring wire slightly protrudes from one facet of Allen wrench. Compressed spring retains Allen screw. Tool used with Allen-head screws in cramped spaces with little or no room for fingers to hold fastener while turned by wrench.
Spring Break: A Lesson in Circuits. "This Old House" College Style.
ERIC Educational Resources Information Center
Duch, Barbara
2001-01-01
Introduces students to the topics of electricity and circuits within the context of house wiring. Explores the properties of series and parallel circuits, researches local wiring codes, calculates the current used by appliances based on their power ratings, and designs circuits in a typical kitchen. (Author/ASK)
NASA Technical Reports Server (NTRS)
Gaspar, Kenneth C.
1987-01-01
New harness for electrical wiring includes plugs that do not loosen from vibration. Ground braids prevented from detaching from connectors and constrained so braids do not open into swollen "birdcage" sections. Spring of stainless steel encircles ground braid. Self-locking connector contains ratchet not only preventing connector from opening, but tightens when vibrated.
Sleeve Push Technique: A Novel Method of Space Gaining.
Verma, Sanjeev; Bhupali, Nameksh Raj; Gupta, Deepak Kumar; Singh, Sombir; Singh, Satinder Pal
2018-01-01
Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel-titanium open coil springs. The disadvantage of nickel-titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT). The nickel-titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing) can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel-titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.
Murdoch, R.O.; Record, F.A.
1963-01-29
This invention relates to a fast-acting spring-loaded electrical switch which can break a 1500-volt circuit in one millisecond without arcing. In particular, a springloaded shorting bar is held in tension by a fusible wire. Passage of an electrical current pulse through the fusible wire breaks the fuse thereby releasing the shorting bar to open one and close another electrical circuit. (AEC)
A study on a wheel-based stair-climbing robot with a hopping mechanism
NASA Astrophysics Data System (ADS)
Kikuchi, Koki; Sakaguchi, Keisuke; Sudo, Takayuki; Bushida, Naoki; Chiba, Yasuhiro; Asai, Yuji
2008-08-01
In this study, we propose a simple hopping mechanism using the vibration of a two-degree-of-freedom system for a wheel-based stair-climbing robot. The robot, consisting of two bodies connected by springs and a wire, hops by releasing energy stored in the springs and quickly travels using wheels mounted in its lower body. The trajectories of the bodies during hopping change in accordance with the design parameters, such as the reduced mass of the two bodies, the mass ratio between the upper and lower bodies, the spring constant, the control parameters such as the initial contraction of the spring and the wire tension. This property allows the robot to quickly and economically climb up and down stairs, leap over obstacles, and landing softly without complex control. In this paper, the characteristics of hopping motion for the design and control parameters are clarified by both numerical simulations and experiments. Furthermore, using the robot design based on the results the abilities to hop up and down a step, leap over a cable, and land softly are demonstrated.
Ishida, Takayoshi; Yoon, Hyung Sik; Ono, Takashi
2013-10-01
In nongrowing patients with skeletal Class II malocclusion, premolar extraction or maxillary distalization can be used as camouflage treatment. Zygomatic anchorage enables distalization in uncooperative or noncompliant patients. We describe 1 such procedure in a 24-year-old woman. We used novel improved superelastic nickel-titanium archwires combined with nickel-titanium open-coil springs to provide a constant and continuous low force to the dentition. We were able to successfully eliminate the protrusive profile and correct the Class II molar relationship using this system of zygomatic anchorage. The posterior occlusal relationships were improved to achieve Class I canine and molar relationships on both sides, and ideal overbite and overjet relationships were established. Facial esthetics was improved with decreased protrusion of the upper and lower lips. The method used here is a promising alternative to traditional distalization techniques and might offer an effective and simple means of distalizing maxillary molars in uncooperative patients. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Brudnicki, Myron (Inventor)
1995-01-01
Rotary actuators and other mechanical devices incorporating shape memory alloys are provided herein. Shape memory alloys are a group of metals which when deformed at temperatures below their martensite temperatures, resume the shapes which they had prior to the deformation if they are heated to temperatures above their austensite temperatures. Actuators in which shape memory alloys are employed include bias spring types, in which springs deform the shape memory alloy (SMA), and differential actuators, which use two SMA members mechanically connected in series. Another type uses concentric cylindrical members. One member is in the form of a sleeve surrounding a cylinder, both being constructed of shape memory alloys. Herein two capstans are mounted on a shaft which is supported in a framework. Each capstan is capable of rotating the shaft. Shape memory wire, as two separate lengths of wire, is wrapped around each capstan to form a winding around that capstan. The winding on one capstan is so wrapped that the wire is in a prestretched state. The winding on the other capstan is so wrapped that the wire is in a taut, but not a prestretched, state. Heating one performs work in one direction, thus deforming the other one. When the other SMA is heated the action is reversed.
Moore, Amy M; Dennison, David G
2014-06-01
The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. A retrospective review (2006-2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. A retrospective case series, Level IV.
Nickel titanium T-loop wire dimensions for en masse retraction.
Almeida, Layene; Ribeiro, Alexandre; Parsekian Martins, Renato; Viecilli, Rodrigo; Parsekian Martins, Lídia
2016-09-01
To compare the force system produced by nickel-titanium T-loop springs made with wires of different dimensions. Thirty compound T-loop springs were divided into three groups according to the dimensions of the nickel-titanium wire used for its design: 0.016" × 0.022", 0.017" × 0.025", and 0.018" × 0.025". The loops were tested on the Orthodontic Force Tester machine at an interbracket distance of 23 mm and activated 9 mm. The force in the y-axis and the moment in the x-axis were registered while the calculated moment to force ratio was recorded at each .5 mm of deactivation. The data were analyzed by three analyses of variance of repeated measures to detect differences and interactions between deactivation and wire size on force, moment, and moment-force ratios (M/F). All groups had significantly different forces (P < .001). The 0.016" × 0.022" wire produced 1.78N of force while the 0.017" × 0.025" and the 0.018" × 0.025" produced 2.81 N and 3.25 N, respectively. The 0.016" × 0.022" wire produced lower moments (11.6 Nmm) than the 0.017" × 0.025" and 0.018" × 0.025" wires, which produced similar moments (13.9 Nmm and 14.4Nmm, respectively). The M/F produced was different for all groups; 0.016" × 0.022" T-loops produced 6.7 mm while the 0.017" × 0.025" and 0.018" × 0.025" T-loops produced 5.0 mm and 4.5 mm, respectively. An interaction was detected for all variables between deactivation and groups. The larger wires tested produced higher forces with slight increase on the moments, but the M/F produced by the 0.016" × 0.022" wire was the highest found.
NASA Technical Reports Server (NTRS)
Asnani, Vivake M.; Benzing, Jim; Kish, Jim C.
2011-01-01
The spring tire is made from helical springs, requires no air or rubber, and consumes nearly zero energy. The tire design provides greater traction in sandy and/or rocky soil, can operate in microgravity and under harsh conditions (vastly varying temperatures), and is non-pneumatic. Like any tire, the spring tire is approximately a toroidal-shaped object intended to be mounted on a transportation wheel. Its basic function is also similar to a traditional tire, in that the spring tire contours to the surface on which it is driven to facilitate traction, and to reduce the transmission of vibration to the vehicle. The essential difference between other tires and the spring tire is the use of helical springs to support and/or distribute load. They are coiled wires that deform elastically under load with little energy loss.
VIEW EASTLEFTBUILDING 4NO 1 WIRE MILL (1871) RIGHTBUILDING 25NO 2 ...
VIEW EAST-LEFT-BUILDING 4-NO 1 WIRE MILL (1871) RIGHT-BUILDING 25-NO 2 WIRE MILL (c.1853) RIGHT-BUILDING 23 WIRE MILL & PATENTING (1853 & 1900)-BEHIND 25 CENTER-PEDESTRIAN BRIDGE (C.1873) - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
The design and evaluation of superconducting connectors
NASA Technical Reports Server (NTRS)
Payne, J. E.
1982-01-01
The development of a superconducting connector for superconducting circuits on space flights is described. It is proposed that such connectors be used between the superconducting readout loop and the SQUID magnetometer in the Gravity Probe B experiment. Two types of connectors were developed. One type employs gold plated niobium wires making pressure connections to gold plated niobium pads. Lead-plated beryllium-copper spring contacts can replace the niobium wires. The other type is a rigid solder or weld connection between the niobium wires and the niobium pads. A description of the methods used to produce these connectors is given and their performance analyzed.
VIEW WESTBUILDING 23WIRE MILL & PATENTING (c.1853 & c.1900)CENTER BUILDING ...
VIEW WEST-BUILDING 23-WIRE MILL & PATENTING (c.1853 & c.1900)-CENTER BUILDING 25- NO 2 WIRE MILL (c.1853) BEHIND 23 TO RIGHT - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
Specifications for structural range improvements.
H. Reed Sanderson; Thomas M. Quigley; Emery E. Swan; Louis R. Spink
1990-01-01
Construction specifications and illustrations are provided for several types of barbed wire and pole fences, gates, cattle guards, stiles, spring developments, water troughs, stock ponds, trick tanks, and livestock access trails.
The Begg's uprighting spring – Revisited
Kumar, Vinay; Sundareswaran, Shobha
2015-01-01
Uprighting springs, an integral part of the Begg ligsht wire differential force technique is gaining more and more popularity, as a useful adjunct in contemporary preadjusted edgewise appliance systems as well. It can be used with brackets containing vertical slots for mesiodistal crown uprighting, or as braking auxiliaries providing additional anchorage while protracting posteriors. Here, we present a simple and quick chair side method of fabricating and customizing uprighting springs according to the required crown/root movement for correction. This communication would serve as a ready reckoner during fabrication of the springs, thus dispelling the confusion that usually arises regarding direction and position of the coil and active arm. PMID:25657990
Multiple-layer printed-wiring trace connector
NASA Technical Reports Server (NTRS)
Pizzeck, D. E.
1977-01-01
Nickel-plated spring-steel foil connector is hollow pin, with lengthwise slit, that is inserted into improperly plated-through holes. Edges of connector make positive contact with copper pads within hole.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-20
... Spring Hill, TN; Notice of Negative Determination Regarding Application for Reconsideration By... negative determination applicable to workers and former workers at American Food and Vending, Spring Hill... eligible for TAA because they are service workers who provided services to General Motors, Spring Hill...
Superelasticity of NiTi Ring-Shaped Springs Induced by Aging for Cranioplasty Applications
NASA Astrophysics Data System (ADS)
Morawiec, Henryk Z.; Lekston, Zdzisław H.; Kobus, Kazimierz F.; Węgrzyn, Marek C.; Drugacz, Jan T.
2009-08-01
This paper concerns the application of titanium-nickel rings in modeling the cranium. After being fixed to the osseous margins, the ring’s expansion at the same time broadens and shortens the cranium vault. The rings formed from a straight superelastic wire, flattened to an ellipse, do not show the presence of a typical force plateau but rather a pseudoelastic loop during loading-unloading in the relationship between the force and the deflection. Based on the idea that superelasticity in more complex shape-springs may be induced by the precipitation hardening process, the further studies were carried out on alloys with higher nickel contents (51.06 at.% Ni). The rings that had been formed were welded and aged at an optimal temperature and time. The improved superelastic behavior during compression and unloading the rings was obtained by introducing small deformation by drawing the quenched wires before forming the rings and aging. Very positive clinical reshaping by long-term distraction with the superelastic ring-shaped springs was achieved in young children under one year and a less spectacular effect was observed in the group of older children.
24 CFR 3280.611 - Vents and venting.
Code of Federal Regulations, 2010 CFR
2010-04-01
... be DWV grade nylon or acetal; (iii) Spring shall be stainless steel wire, type 302; (iv) Sealing disc...) Materials—(1) Pipe. Vent piping shall be standard weight steel, wrought iron, brass, copper tube DWV, listed...
24 CFR 3280.611 - Vents and venting.
Code of Federal Regulations, 2011 CFR
2011-04-01
... be DWV grade nylon or acetal; (iii) Spring shall be stainless steel wire, type 302; (iv) Sealing disc...) Materials—(1) Pipe. Vent piping shall be standard weight steel, wrought iron, brass, copper tube DWV, listed...
40 CFR 1065.910 - PEMS auxiliary equipment for field testing.
Code of Federal Regulations, 2013 CFR
2013-07-01
... temperature rating of at least 315 °C for flexible connectors. You may use connectors with a spring-steel wire... frames, trailer hitch receivers, walk spaces, and payload tie-down fittings. We recommend mounting...
Saito, Kan; Jang, Insan; Kubota, Kazumi; Hoshino, Tomonori; Hotokezaka, Hitoshi; Yoshida, Noriaki; Fujiwara, Taku
2013-01-01
A newly designed removable appliance with a shape-memory wire was used for the orthodontic treatment of the anterior teeth in an 11-year-old child who had autism and intellectual disability. The device was designed to reduce the lateral incisor crossbite and the central incisors' labial rotation. The child was treated for 1 year with this removable appliance. Tooth movement was analyzed using cephalograms and surface data were derived from study models. This device proved to be very durable. The lateral incisor crossbite was corrected, and the inclination of the upper central incisors and the interincisal angle were improved. This appliance exerts light and continuous orthodontic force, without requiring any adjustments of the spring wire. The appliance also facilitated orthodontic treatment in a child with intellectual disability in whom treatment with a standard orthodontic device would be unsuitable. ©2012 Special Care Dentistry Association and Wiley Periodicals, Inc.
New design for a rotatory joint actuator made with shape memory alloy contractile wire
NASA Astrophysics Data System (ADS)
Wang, Guoping; Shahinpoor, Mohsen
1996-05-01
A design approach for a rotatory joint actuator using a contractile shape memory alloy (SMA) wire is presented and an example design is followed. In this example, the output torque of the actuator is 18 Newton-meters, and its angular range is 30 degrees. Compared with a SMA spring type actuating component, a SMA wire type actuating component uses less SMA material and uses less electrical energy when it is electrically powered. On the other hand, a SMA wire type actuating component must have a large SMA wire length to produce a required amount of angular rotation of the joint. When pulleys are used to arrange a lengthy SMA wire in a small space, the friction between pulleys and pins is introduced and the performance of the joint actuator is degenerated to some degree. The investigated joint actuator provides a good chance for developing powered orthoses with SMA actuators for disabled individuals. It can relieve the weight concern with hydraulic and motor-powered orthoses and the safety concern with motor-powered orthoses. When electrically powered, a SMA actuator has the disadvantage of low energy efficiency.
Scale-up of 2G wire manufacturing at American Superconductor Corporation
NASA Astrophysics Data System (ADS)
Fleshler, S.; Buczek, D.; Carter, B.; Cedrone, P.; DeMoranville, K.; Gannon, J.; Inch, J.; Li, X.; Lynch, J.; Otto, A.; Podtburg, E.; Roy, D.; Rupich, M.; Sathyamurthy, S.; Schreiber, J.; Thieme, C.; Thompson, E.; Tucker, D.; Nagashima, K.; Ogata, M.
2009-10-01
American Superconductor Corporation (AMSC) has developed the base technology and a manufacturing line for initial volume production of low-cost second generation high temperature superconductor (2G HTS) wire for commercial and military applications. The manufacturing line is based on reel-to-reel processing of wide HTS strips using rolling assisted bi-axially textured substrate (RABiTS™) for the template and Metal Organic Deposition (MOD) for the HTS layer. AMSC’s wide strip process is a low cost manufacturing technology since multiple wires are produced in a single manufacturing pass by slitting the wide strip to narrower width in the last stage of the manufacturing process. Industry standard 4.4 mm wide wires are produced by laminating metallic foils, such as copper, stainless steel or any other material, to the HTS insert wire, and are chosen to tailor the electrical, thermal and mechanical properties of the wire for specific applications. The laminated, 4.4 mm wide wires are known as “344 superconductors.” In this paper, we summarize the status of AMSC’s manufacturing capability, the performance of the wire presently being produced, as well as the cost and technical advantages of AMSC’s manufacturing approach. In addition, future direction for research and development to improve electrical performance is presented.
Song, Geun Soo; Lee, Yeon Soo
2015-07-01
This study aimed to quantify morphological characteristics of the posterior lumbar spinous process, which may affect stable implantation of screwless wire spring loops. Virtual implantations of a screwless wire spring loop onto pairs of lumbar spinous processes were performed for computed tomography (CT)-derived three-dimensional vertebral models of 40 Korean subjects. Morphological parameters of lumbar vertebrae 1 through 5 (L1-L5) were measured with regard to bone-implant interference. In males, the transspinous process fixation lengths decreased from 57.8±3.0mm to 48.8±3.2mm as the lumbar joints descend from L1-L2 to L4-L5, with those in females about 4.1±0.4mm shorter (p<0.05) than in males through all lumbar joints. The fixation angle on the sagittal plane varied from 105.0° to 101.3° relative to the transverse plane as the vertebrae descend. The clenched thickness in females was the least (6.7±1.2mm) for the L2 lower spinous process and the greatest (8.1±2.2mm) for the L4 upper spinous process; this was 1.0±10.3mm less than that for males at corresponding levels (p>0.05). The ratio of the spinous process clenched thickness to the transspinous fixation length increased from 0.133±0.016 to 0.196±0.076 for the upper spinous processes as the lumbar joints descend. The ratio of the spinous process clenched thickness to the transspinous fixation length varies, depending on gender and whether the clenched level is the upper or lower spinous process. These parameters related to the clenching fixation stability should be considered in development and implantations of the screwless wire spring loop. Copyright © 2015 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Shibukawa, Takuya; Masumoto, Shinichi; Ozawa, Kyoichiro; Ohnishi, Hiroaki; Muramatsu, Norihito; Ishikawa, Takatsugu; Miyabe, Manabu; Tsuchikawa, Yusuke; Yamazaki, Ryuji; Matsumura, Yuji; Mizutani, Keigo; Hashimoto, Toshikazu; Hamano, Hirotomo; LEPS2/BGOegg Collaboration
2014-09-01
Properties of vector mesons, such as ω mesons, in nucleus are intensively measured to study interactions between mesons and nuclear medium. To study ω meson properties in nuclei, we search for the nuclear ω bound states in the LEPS2/BGOegg experiment at SPring-8. If a strongly bounded ω state exists and binding energy is measured, it gives a phenomenological information about interactions between ω meson and nuclei. ω meson is produced using the GeV γ rays at SPring-8/LEPS2 beamline. The ω bound state is searched from the missing mass measurements of forward going protons. ω meson production is identified by detecting γ and proton from ωN --> N* --> γp or ωN --> γΔ --> γπ p reaction. In the BGOegg experiment, charged particles are detected by Cylindrical Drift Chamber(CDC) and Inner Plastic Scintillators (IPS) around the target. CDC has 4 layers of stereo wires and each layer has 72 sense wires. IPS consists of 30 plastic scintillators. In this talk, the performance of CDC and IPS are described in detail. Properties of vector mesons, such as ω mesons, in nucleus are intensively measured to study interactions between mesons and nuclear medium. To study ω meson properties in nuclei, we search for the nuclear ω bound states in the LEPS2/BGOegg experiment at SPring-8. If a strongly bounded ω state exists and binding energy is measured, it gives a phenomenological information about interactions between ω meson and nuclei. ω meson is produced using the GeV γ rays at SPring-8/LEPS2 beamline. The ω bound state is searched from the missing mass measurements of forward going protons. ω meson production is identified by detecting γ and proton from ωN --> N* --> γp or ωN --> γΔ --> γπ p reaction. In the BGOegg experiment, charged particles are detected by Cylindrical Drift Chamber(CDC) and Inner Plastic Scintillators (IPS) around the target. CDC has 4 layers of stereo wires and each layer has 72 sense wires. IPS consists of 30 plastic scintillators. In this talk, the performance of CDC and IPS are described in detail. All members of the collaboration are listed on http://www.lns.tohoku.ac.jp/ ~bgoegg/collaboration.html
Walker, Mary P; White, Richard J; Kula, Katherine S
2005-06-01
Titanium-based alloys have high corrosion resistance because they form a thin, stable oxide layer. Nevertheless, fluoride prophylactic agents can cause corrosion and associated discoloration of titanium-based orthodontic wires. The purpose of this investigation was to study the effects of fluoride prophylactic agents on the mechanical properties of nickel-titanium (Ni-Ti) and copper-nickel-titanium (Cu-Ni-Ti) orthodontic archwires. Preformed rectangular Ni-Ti and Cu-Ni-Ti wires were immersed in either an acidulated fluoride agent, a neutral fluoride agent, or distilled water (control) for 1.5 hours at 37 degrees C. After immersion, the loading and unloading elastic modulus and yield strength of the wires were measured with a 3-point bend test in a water bath at 37 degrees C, in accordance with the criteria in the current American National Standard/American Dental Association Specification No. 32 for Orthodontic Wires (2000). Scanning electron microscopy was also used to characterize the effects of the fluoride treatment on the wire topography. Unloading mechanical properties of Ni-Ti orthodontic wires were significantly decreased after exposure to both fluoride agents (1-way analysis of variance [ANOVA] and Dunnett's post hoc, alpha =.05); however, Cu-Ni-Ti wire mechanical properties were not significantly affected by either fluoride agent (1-way ANOVA, alpha =.05). Corrosive changes in surface topography were observed for both wires, with Cu-Ni-Ti appearing to be more severely affected. The results suggest that using topical fluoride agents with Ni-Ti wire could decrease the functional unloading mechanical properties of the wire and contribute to prolonged orthodontic treatment.
27 CFR 9.143 - Spring Mountain District.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Spring Mountain District. 9.143 Section 9.143 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.143 Spring Mountain District. (a) Name. The...
27 CFR 9.143 - Spring Mountain District.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Spring Mountain District. 9.143 Section 9.143 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.143 Spring Mountain District. (a) Name. The...
27 CFR 9.143 - Spring Mountain District.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Spring Mountain District. 9.143 Section 9.143 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.143 Spring Mountain District. (a) Name. The...
27 CFR 9.143 - Spring Mountain District.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Spring Mountain District. 9.143 Section 9.143 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.143 Spring Mountain District. (a) Name. The...
27 CFR 9.143 - Spring Mountain District.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Spring Mountain District. 9.143 Section 9.143 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.143 Spring Mountain District. (a) Name. The...
7 CFR 1755.501 - Definitions applicable to §§ 1755.501 through 1755.510.
Code of Federal Regulations, 2013 CFR
2013-01-01
... in the ANSI/NFPA 70-1999, NEC ®: A fine gauge section of wire or cable that serves as a fuse (that is... telecommunications cable and wire plant, and protective devices. (Reprinted with permission from NFPA 70-1999, the.../code_of_federal_regulations/ibr_locations.html. AWG. American Wire Gauge. BET. Building entrance...
7 CFR 1755.501 - Definitions applicable to §§ 1755.501 through 1755.510.
Code of Federal Regulations, 2012 CFR
2012-01-01
... in the ANSI/NFPA 70-1999, NEC ®: A fine gauge section of wire or cable that serves as a fuse (that is... telecommunications cable and wire plant, and protective devices. (Reprinted with permission from NFPA 70-1999, the.../code_of_federal_regulations/ibr_locations.html. AWG. American Wire Gauge. BET. Building entrance...
7 CFR 1755.501 - Definitions applicable to §§ 1755.501 through 1755.510.
Code of Federal Regulations, 2014 CFR
2014-01-01
... in the ANSI/NFPA 70-1999, NEC ®: A fine gauge section of wire or cable that serves as a fuse (that is... telecommunications cable and wire plant, and protective devices. (Reprinted with permission from NFPA 70-1999, the.../code_of_federal_regulations/ibr_locations.html. AWG. American Wire Gauge. BET. Building entrance...
1. Historic American Buildings Survey, P. Kent Fairbanks, Photographer August, ...
1. Historic American Buildings Survey, P. Kent Fairbanks, Photographer August, 1968 WEST (FRONT) ELEVATION. - Spring City Area Study, Public School, Fourth & E Streets, Spring City, Sanpete County, UT
1. Historic American Buildings Survey, P. Kent Fairbanks, Photographer August, ...
1. Historic American Buildings Survey, P. Kent Fairbanks, Photographer August, 1968 SOUTH (FRONT) ELEVATION. - Spring City Area Study, Bishop's Storehouse, Fourth & E Streets, Spring City, Sanpete County, UT
1. Historic American Buildings Survey Nathaniel R. Ewan, Photographer May ...
1. Historic American Buildings Survey Nathaniel R. Ewan, Photographer May 19, 1936 EXTERIOR - SOUTHEAST ELEVATION - Cold Spring Presbyterian Church, West side Seashore Road, Cold Spring, Cape May County, NJ
2. Historic American Buildings Survey Nathaniel R. Ewan, Photographer May ...
2. Historic American Buildings Survey Nathaniel R. Ewan, Photographer May 19, 1936 INTERIOR - CHANCEL DETAIL - Cold Spring Presbyterian Church, West side Seashore Road, Cold Spring, Cape May County, NJ
9. Historic American Buildings Survey E. W. Russell, Photographer, February ...
9. Historic American Buildings Survey E. W. Russell, Photographer, February 28, 1935 MAIN BUILDING (ADMINISTRATION) WEST - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
9. Historic American Buildings Survey B. Baxter Matheny, Photographer, Spring, ...
9. Historic American Buildings Survey B. Baxter Matheny, Photographer, Spring, 1973 STAINED GLASS WINDOW IN TOWER (INTERIOR) - First United Methodist Church, 200 North Division Street, Carson City, Carson City, NV
1. Historic American Buildings Survey, Frank C. Brown, Photographer. Spring ...
1. Historic American Buildings Survey, Frank C. Brown, Photographer. Spring of 1935 (a) Ext-- General view. (from Southeast) - Old Gaol, Vestal Street (moved from original site), Nantucket, Nantucket County, MA
2006-01-01
Ports. Logistics Today, Vol.46. Issue 9. 43. Maloni, Michael ., Jackson , Eric. (2005, Spring). North American Container Port Capacity: A...Literature Review. Transportation Journal, Spring 2005. 16-36. Maloni, Michael ., Jackson , Eric. (2005, Summer). North American Container Port Capacity: An
41. Historic American Buildings Survey E. W. Russell, Photographer, May ...
41. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 CORNICE AROUND ROTUNDA WALL, THIRD FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
3. Historic American Buildings Survey E. W. Russell, Photographer, May ...
3. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 NORTH ELEVATION (FRONT) LOOKING SOUTH EAST - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
92. DETAIL OF GENERAL ELECTRIC 250HP SYNCHRONOUS MOTOR FROM SLIP ...
92. DETAIL OF GENERAL ELECTRIC 250-HP SYNCHRONOUS MOTOR FROM SLIP RING END. NOTE BOLTS AND SPRINGS OF BRAKE BAND, HEAVY-WIRE ARMATURE WINDINGS, AND TIGHTLY WOUND STATOR (FIELD) COILS. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO
Parametric analysis of a shape memory alloy actuated arm
NASA Astrophysics Data System (ADS)
Wright, Cody; Bilgen, Onur
2016-04-01
Using a pair of antagonistic Shape Memory Allow (SMA) wires, it may be possible to produce a mechanism that replicates human musculoskeletal movement. The movement of interest is the articulation of the elbow joint actuated by the biceps brachii muscle. In an effort to understand the bio-mechanics of the arm, a single degree of freedom crankslider mechanism is used to model the movement of the arm induced by the biceps brachii muscle. First, a purely kinematical analysis is performed on a rigid body crank-slider. Force analysis is also done modeling the muscle as a simple linear spring. Torque, rocking angle, and energy are calculated for a range of crank-slider geometries. The SMA wire characteristics are experimentally determined for the martensite detwinned and full austenite phases. Using the experimental data, an idealized actuator characteristic curve is produced for the SMA wire. Kinematic and force analyses are performed on the nonlinear wire characteristic curve and a linearized wire curve; both cases are applied to the crankslider mechanism. Performance metrics for both cases are compared, followed by discussion.
Seyyed Aghamiri, S M; Ahmadabadi, M Nili; Raygan, Sh
2011-04-01
The shape memory nickel-titanium alloy has been applied in many fields due to its unique thermal and mechanical performance. One of the successful applications of NiTi wires is in orthodontics because of its good characteristics such as low stiffness, high spring back, high stored energy, biocompatibility, superelasticity and shape memory effect. The mechanical properties of wires are paid special attention which results in achieving continuous optimal forces and eventually causing rapid tooth movement without any damage. The behavior of the alloy can be controlled by chemical composition and thermo-mechanical treatment during the manufacturing process. In this study two kinds of commercial superelastic NiTi archwires of 0.41 mm diameter were investigated: Copper NiTi and Highland Metal. The chemical analysis of both wires was estimated by energy dispersive spectroscopy (EDS). It was showed that Copper NiTi wire contained copper and chromium. The two types of wires were exposed to different heat treatment conditions at 400 and 500 °C for 10 and 60 min to compare the behavior of the wires at aged and as-received conditions. Phase transformation temperatures clarified by differential scanning calorimetry (DSC) showed B2 <--> R <--> B19 transformation in Highland Metal wire and B2 <--> B19(') transformation in Copper NiTi wire. Three point bending (TPB) tests in the certain designed fixture were performed at 37 °C to evaluate the mechanical behavior of the wires. The experimental results revealed the superelastic behavior of the Highland Metal wire after 60 min ageing at 400 and 500 °C and the plastic deformation of the Copper NiTi wire after annealing due to the effect of copper in the alloy composition. Copyright © 2010 Elsevier Ltd. All rights reserved.
5. Historic American Buildings Survey B. Baxter Matheny, Photographer, Spring, ...
5. Historic American Buildings Survey B. Baxter Matheny, Photographer, Spring, 1973 METAL CEILING AND ROSE WINDOW, ABOVE LOWERED CEILING - First United Methodist Church, 200 North Division Street, Carson City, Carson City, NV
35. Historic American Buildings Survey E. W. Russell, Photographer, May ...
35. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 ROTUNDA, THIRD FLOOR, LOOKING W. FROM E. HALLWAY - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
25. Historic American Buildings Survey E. W. Russell, Photographer, May ...
25. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 FRONT ENTRANCE DOOR TO WEST OF MAIN ENTRANCE - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
39. Historic American Buildings Survey E. W. Russell, Photographer, May ...
39. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 CLOSE-UP OF ROTUNDA BALUSTRADE, THIRD FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
21. Historic American Buildings Survey E. W. Russell, Photographer, May ...
21. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 CLOSE-UP OF IRON COLUMN CAP, SOUTH PORTICO - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
15. Historic American Buildings Survey E. W. Russell, Photographer, May ...
15. Historic American Buildings Survey E. W. Russell, Photographer, May 8, 1936 CLOSE-UP OF CORNICE ON REAR OF BUILDING - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
36. Historic American Buildings Survey E. W. Russell, Photographer, May ...
36. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 ROTUNDA, 3rd FLOOR, SHOWING N. HALL - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
24. Historic American Buildings Survey E. W. Russell, Photographer, May ...
24. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 N. DOOR OPENING ON PORTICO (OR ARCADE) - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
6. Historic American Buildings Survey E. W. Russell, Photographer, May ...
6. Historic American Buildings Survey E. W. Russell, Photographer, May 8, 1936 SOUTH ELEVATION OF W END WING (REAR) - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
77 FR 74174 - North American Free Trade Agreement (NAFTA), Article 1904 Binational Panel Reviews
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-13
... Department of Commerce's Final Determination of Carbon and Certain Alloy Steel Wire Rod from Canada... concerning Carbon and Certain Alloy Steel Wire Rod from Canada. The Secretariat was instructed to issue a...
5. Within building #5, the forming of chain from wire, ...
5. Within building #5, the forming of chain from wire, as well as other operations, was powered by such belt-driven wheels and shafts. - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA
Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis
2015-01-01
Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05). Corrosion rate of brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them.
Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis
2015-01-01
Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05). Corrosion rate of brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them. PMID:26697148
TARDEC FMEA TRAINING: Understanding and Evaluating Failure Mode and Effects Analyses (FMEA)
2012-06-07
Tip Brass 1 1.1.2.1.3 Ball Tungsten Carbide 1 1.1.2.1.4 Blue Ink Ink .1 grams 1.1.2.2 Steel 1 1.1.3 ABS/PP 1 Ink/Spring Assembly Ink Tube Spring Nib...does not meet airflow (8) voltage circuit analy sis of vehic le - New Yuma - test requirements (6 in. WCtJ.P -Blown fuse control c ircuit vehicle...1500 CFM for XXXX) - Broken wire - Compare fuse capacity to in-rush current and stall current during high ambient temperature conditions - Review
30. Historic American Buildings Survey E. W. Russell, Photographer, May ...
30. Historic American Buildings Survey E. W. Russell, Photographer, May 8, 1936 STAIR IN HALL TOWARDS REAR, W. EXTENSION, 1st FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
1. Historic American Buildings Survey COPIED E. W. Russell, ...
1. Historic American Buildings Survey COPIED - E. W. Russell, Photographer, August 31, 1936 75TH ANNIVERSARY YEARBOOK (NOT COPYRIGHT) - VIEW OF ORIGINAL BUILDING - Spring Hill College, Original Building, Old Shell Road, Spring Hill, Mobile County, AL
20. Historic American Buildings Survey E. W. Russell, Photographer, May ...
20. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 CLOSE-UP OF STUCCO PORTICO COLUMN (SOUTH) FIRST FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
22. Historic American Buildings Survey E. W. Russell, Photographer, May ...
22. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 BASE OF IRON COLUMN TO PORTICO (SOUTH) FIRST FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
18. Historic American Buildings Survey E. W. Russell, Photographer, May ...
18. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 VIEW OF PORTICO COLUMNS LOOKING N. E., 1st FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
5. Historic American Buildings Survey E. W. Russell, Photographer, February ...
5. Historic American Buildings Survey E. W. Russell, Photographer, February 28, 1935 REAR VIEW OF MAIN BLDG. S.W. (REAR FACES S.) - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
Progress in American Superconductor's HTS wire and optimization for fault current limiting systems
NASA Astrophysics Data System (ADS)
Malozemoff, Alexis P.
2016-11-01
American Superconductor has developed composite coated conductor tape-shaped wires using high temperature superconductor (HTS) on a flexible substrate with laminated metal stabilizer. Such wires enable many applications, each requiring specific optimization. For example, coils for HTS rotating machinery require increased current density J at 25-50 K. A collaboration with Argonne, Brookhaven and Los Alamos National Laboratories and several universities has increased J using an optimized combination of precipitates and ion irradiation defects in the HTS. Major commercial opportunities also exist to enhance electric power grid resiliency by linking substations with distribution-voltage HTS power cables [10]. Such links provide alternative power sources if one substation's transmission-voltage power is compromised. But they must also limit fault currents which would otherwise be increased by such distribution-level links. This can be done in an HTS cable, exploiting the superconductor-to-resistive transition when current exceeds the wires' critical J. A key insight is that such transitions are usually nonuniform; so the wire must be designed to prevent localized hot spots from damaging the wire or even generating gas bubbles in the cable causing dielectric breakdown. Analysis shows that local heating can be minimized by increasing the composite tape's total thickness, decreasing its total resistance in the normal state and decreasing its critical J. This conflicts with other desirable wire characteristics. Optimization of these conflicting requirements is discussed.
The Quantum Socket: Wiring for Superconducting Qubits - Part 1
NASA Astrophysics Data System (ADS)
McConkey, T. G.; Bejanin, J. H.; Rinehart, J. R.; Bateman, J. D.; Earnest, C. T.; McRae, C. H.; Rohanizadegan, Y.; Shiri, D.; Mariantoni, M.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.
Quantum systems with ten superconducting quantum bits (qubits) have been realized, making it possible to show basic quantum error correction (QEC) algorithms. However, a truly scalable architecture has not been developed yet. QEC requires a two-dimensional array of qubits, restricting any interconnection to external classical systems to the third axis. In this talk, we introduce an interconnect solution for solid-state qubits: The quantum socket. The quantum socket employs three-dimensional wires and makes it possible to connect classical electronics with quantum circuits more densely and accurately than methods based on wire bonding. The three-dimensional wires are based on spring-loaded pins engineered to insure compatibility with quantum computing applications. Extensive design work and machining was required, with focus on material quality to prevent magnetic impurities. Microwave simulations were undertaken to optimize the design, focusing on the interface between the micro-connector and an on-chip coplanar waveguide pad. Simulations revealed good performance from DC to 10 GHz and were later confirmed against experimental measurements.
Reusable, tamper-indicating seal
Ryan, Michael J.
1978-01-01
A reusable, tamper-indicating seal comprises a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body -- visible from outside the seal -- adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same position. A new pattern of colored balls will appear in the segregated location when the seal is relocked.
28. Historic American Buildings Survey E. W. Russell, Photographer, May ...
28. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 INTERIOR VIEW OF MAIN ENTRANCE TO MAIN HALL, 1st FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
23. Historic American Buildings Survey E. W. Russell, Photographer, May ...
23. Historic American Buildings Survey E. W. Russell, Photographer, May 8, 1936 EXTERIOR VIEW OF DOOR IN N. WALL (FRONT) 1st FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
27. Historic American Buildings Survey E. W. Russell, Photographer, May ...
27. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 EXTERIOR VIEW OF REAR DOOR TO MAIN HALLWAY, 1st FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
33. Historic American Buildings Survey E. W. Russell, Photographer, May ...
33. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 VIEW OF STAIR FROM 2nd STORY HALL, W. END OF BUILDING - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
19. Historic American Buildings Survey E. W. Russell, Photographer, May ...
19. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 SOUTH ELEVATION (REAR) SHOWING ROUND IRON COLUMN AND SQUARE STUCCO COLUMN - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
26. Historic American Buildings Survey E. W. Russell, Photographer, May ...
26. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 EXTERIOR VIEW OF WINDOW IN REAR S. WALL, 1st FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
14. Historic American Buildings Survey E. W. Russell, Photographer, May ...
14. Historic American Buildings Survey E. W. Russell, Photographer, May 8, 1936 GENERAL VIEW OF S. ELEVATION (REAR) FROM 3rd STORY REAR PORCH - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
34. Historic American Buildings Survey E. W. Russell, Photographer, May ...
34. Historic American Buildings Survey E. W. Russell, Photographer, May 8, 1936 VIEW OF STAIR FROM REAR (SOUTH) OF HALL, 2nd FLOOR - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
Full 3-dimensional digital workflow for multicomponent dental appliances: A proof of concept.
van der Meer, W Joerd; Vissink, Arjan; Ren, Yijin
2016-04-01
The authors used a 3-dimensional (3D) printer and a bending robot to produce a multicomponent dental appliance to assess whether 3D digital models of the dentition are applicable for a full digital workflow. The authors scanned a volunteer's dentition with an intraoral scanner (Lava Chairside Oral Scanner C.O.S., 3M). A digital impression was used to design 2 multicomponent orthodontic appliances. Biocompatible acrylic baseplates were produced with the aid of a 3D printer. The metal springs and clasps were produced by a bending robot. The fit of the 2 appliances was assessed by 2 experienced orthodontists. The authors assessed both orthodontic appliances with the volunteer's dentition and found the fit to be excellent. Clinicians can fully produce a multicomponent dental appliance consisting of both an acrylic baseplate and other parts, such as clasps, springs, or screws, using a digital workflow process without the need for a physical model of the patient's dentition. Plaster models can be superfluous for orthodontic treatment as digital models can be used in all phases of a full digital workflow in orthodontics. The arduous task of making a multicomponent dental appliance that involves bending wires can possibly be replaced by a computer, design software, a 3D printer, and a bending robot. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.
Elliott, Diane G.; Conway, Carla M.; Bruno, D.W.; Elliott, D.G.; Nowak, B.
2014-01-01
Bacterial kidney disease (BKD) caused by Renibacterium salmoninarum can cause significant morbidity and mortality in Chinook salmon (Oncorhynchus tshawytscha), particularly in Chinook salmon of the stream (spring) life history type, which migrate to sea as yearlings rather than subyearlings. R. salmoninarum can be transmitted vertically from the female parent to the progeny in association with the egg, as well as horizontally from fish to fish. This study was conducted as part of a research project to investigate whether the prevalence and intensity of R. salmoninarum infections in adult spring Chinook salmon could affect the survival and pathogen prevalence and intensity in their progeny (Pascho et al., 1991, 1993; Elliott et al., 1995). Fish from two brood years (1988 and 1989) were reared at Dworshak National Fish Hatchery (Idaho, USA) for about 1-1/2 years, released as yearling smolts, and allowed to migrate to the Pacific Ocean for maturation. The majority of progeny fish were marked with coded wire tags (CWTs) about 4 months before they were released from the hatchery so that adult returns could be monitored. The CWTs were implanted in the snouts of the fish by an experienced team of fish markers using automated wire-tagging machines. The intended placement site was the cartilage, skeletal muscle or loose connective tissue of the snout.
Helical wire stress analysis of unbonded flexible riser under irregular response
NASA Astrophysics Data System (ADS)
Wang, Kunpeng; Ji, Chunyan
2017-06-01
A helical wire is a critical component of an unbonded flexible riser prone to fatigue failure. The helical wire has been the focus of much research work in recent years because of the complex multilayer construction of the flexible riser. The present study establishes an analytical model for the axisymmetric and bending analyses of an unbonded flexible riser. The interlayer contact under axisymmetric loads in this model is modeled by setting radial dummy springs between adjacent layers. The contact pressure is constant during the bending response and applied to determine the slipping friction force per unit helical wire. The model tracks the axial stress around the angular position at each time step to calculate the axial force gradient, then compares the axial force gradient with the slipping friction force to judge the helical wire slipping region, which would be applied to determine the bending stiffness for the next time step. The proposed model is verified against the experimental data in the literature. The bending moment-curvature relationship under irregular response is also qualitatively discussed. The stress at the critical point of the helical wire is investigated based on the model by considering the local flexure. The results indicate that the present model can well simulate the bending stiffness variation during irregular response, which has significant effect on the stress of helical wire.
37. Historic American Buildings Survey E. W. Russell, Photographer, May ...
37. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 ROTUNDA, 3rd FLOOR, SHOWING E. HALL BETWEEN ROOMS ON N. AND E. - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
17. Historic American Buildings Survey E. W. Russell, Photographer, May ...
17. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 GENERAL VIEW OF PORTICO (OR ARCADE) LOOKING WEST, 1st FLOOR OF ADMINISTRATION BUILDING - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.
Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B
2017-03-01
To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.
2. Historic American Buildings Survey Copied by E. W. Russell, ...
2. Historic American Buildings Survey Copied by E. W. Russell, Photographer, August 31, 1936 75TH ANNIVERSARY YEARBOOK (NOT COPYRIGHT) - RUINS OF OLD COLLEGE AFTER FIRE OF 1869 - Spring Hill College, Original Building, Old Shell Road, Spring Hill, Mobile County, AL
38. Historic American Buildings Survey E. W. Russell, Photographer, May ...
38. Historic American Buildings Survey E. W. Russell, Photographer, May 7, 1936 N. W. SIDE OF ROTUNDA, 3rd FLOOR, SHOWING W. AND N. HALLS AND STAIR OPENING - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
2. Historic American Buildings Survey Copied by E. W. Russell, ...
2. Historic American Buildings Survey Copied by E. W. Russell, Photographer, August 31, 1936 75TH ANNIVERSARY YEARBOOK (NOT COPYRIGHT) - REAR OF BUILDING BEFORE REINFORCED CONCRETE BALCONIES WERE ADDED - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
1. Historic American Buildings Survey Copied by E. W. Russell, ...
1. Historic American Buildings Survey Copied by E. W. Russell, Photographer, August 31, 1936 75TH ANNIVERSARY YEARBOOK (NOT COPYRIGHT) - FRONT OF MAIN BUILDING BEFORE CLOISTER ARCADE WAS ADDED - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
Evans, A.F.; Roby, D.D.; Collis, K.; Cramer, B.M.; Sheggeby, J.A.; Adrean, L.J.; Battaglia, D.S.; Lyons, Donald E.
2011-01-01
We recovered coded wire tags (CWTs) from a colony of Caspian terns Hydroprogne caspia on Brooks Island in San Francisco Bay, California, to evaluate predation on juvenile salmonids originating from the Sacramento and San Joaquin rivers. Subsamples of colony substrate representing 11.7% of the nesting habitat used by the terns yielded 2,079 salmonid CWTs from fish released and subsequently consumed by terns in 2008. The estimated number of CWTs deposited on the entire tern colony was 40,143 (ranging from 26,763 to 80,288), once adjustments were made to account for tag loss and the total amount of nesting habitat used by terns. Tags ingested by terns and then egested on the colony were undamaged, and the tags' complete numeric codes were still identifiable. The CWTs found on the tern colony indicated that hatchery Chinook salmon Oncorhynchus tshawytscha trucked to and released in San Pablo Bay were significantly more likely to be consumed by Caspian terns than Chinook salmon that migrated in-river to the bay; 99.7% of all tags recovered were from bay-released Chinook salmon. Of the CWTs recovered on the tern colony, 98.0% were from fall-run Chinook salmon, indicating a higher susceptibility to tern predation than for the spring run type. None of the approximately 518,000 wild Chinook salmon that were coded-wire-tagged and released in the basin were recovered on the tern colony, suggesting that the impacts on wild, U.S. Endangered Species Act-listed Chinook salmon populations were minimal in 2008. Overall, we estimate that 0.3% of the approximately 12.3 million coded-wire-tagged Chinook salmon released in the basin in 2008 were subsequently consumed by Caspian terns from the Brooks Island colony. These results indicate that CWTs implanted in juvenile salmon can be recovered from a piscivorous waterbird colony and used to evaluate smolt losses for runs that are tagged. Abstract We recovered coded wire tags (CWTs) from a colony of Caspian terns Hydroprogne caspia on Brooks Island in San Francisco Bay, California, to evaluate predation on juvenile salmonids originating from the Sacramento and San Joaquin rivers. Subsamples of colony substrate representing 11.7% of the nesting habitat used by the terns yielded 2,079 salmonid CWTs from fish released and subsequently consumed by terns in 2008. The estimated number of CWTs deposited on the entire tern colony was 40,143 (ranging from 26,763 to 80,288), once adjustments were made to account for tag loss and the total amount of nesting habitat used by terns. Tags ingested by terns and then egested on the colony were undamaged, and the tags' complete numeric codes were still identifiable. The CWTs found on the tern colony indicated that hatchery Chinook salmon Oncorhynchus tshawytscha trucked to and released in San Pablo Bay were significantly more likely to be consumed by Caspian terns than Chinook salmon that migrated in-river to the bay; 99.7% of all tags recovered were from bay-released Chinook salmon. Of the CWTs recovered on the tern colony, 98.0% were from fall-run Chinook salmon, indicating a higher susceptibility to tern predation than for the spring run type. None of the approximately 518,000 wild Chinook salmon that were coded-wire-tagged and released in the basin were recovered on the tern colony, suggesting that the impacts on wild, U.S. Endangered Species Act-listed Chinook salmon populations were minimal in 2008. Overall, we estimate that 0.3% of the approximately 12.3 million coded-wire-tagged Chinook salmon released in the basin in 2008 were subsequently consumed by Caspian terns from the Brooks Island colony. These results indicate that CWTs implanted in juvenile salmon can be recovered from a piscivorous waterbird colony and used to evaluate smolt losses for runs that are tagged ?? American Fisheries Society 2011.
Zhao, Guang; Sun, Long; Geng, Guojun; Liu, Hongming; Li, Ning; Liu, Suhuan; Hao, Bing
2017-01-01
Background The aim of this study was to compare the effects of currently available preoperative localization methods, including semi-rigid single hook-wire, double-thorn hook-wire, and microcoil, in localizing the pulmonary nodules, thus to select the best technology to assist video-assisted thoracoscopic surgery (VATS) for small ground glass opacities (GGO). Methods Preoperative CT-guided localizing techniques including semi-rigid single hook-wire, double-thorn hook-wire and microcoil were used in re-aerated fresh swine lung for location experiments. The advantages and drawbacks of the three positioning technologies were compared, and then the most optimal technique was used in patients with GGO. Technical success and post-operative complications were used as primary endpoints. Results All three localizing techniques were successfully performed in the re-aerated fresh swine lung. The median tractive force of semi-rigid single hook wire, double-thorn hook wire and microcoil were 6.5, 4.85 and 0.2 N, which measured by a spring dynamometer. The wound sizes in the superficial pleura, caused by unplugging the needles, were 2 mm in double-thorn hook wire, 1 mm in semi-rigid single hook and 1 mm in microcoil, respectively. In patients with GGOs, the semi-rigid hook wires localizations were successfully performed, without any complication that need to be intervened. Dislodgement was reported in one patient before VATS. No major complications related to the preoperative hook wire localization and VATS were observed. Conclusions We found from our localization experiments in the swine lung that, among the commonly used three localization methods, semi-rigid hook wire showed the best operability and practicability than double-thorn hook wire and microcoil. Preoperative localization of small pulmonary nodules with single semi-rigid hook wire system shows a high success rate, acceptable utility and especially low dislodgement in VATS. PMID:29312722
40 CFR Table 1 to Subpart Xxxxxx... - Description of Source Categories Affected by This Subpart
Code of Federal Regulations, 2011 CFR
2011-07-01
... (except springs) made from purchased wire. These facilities also manufacture steel balls; nonferrous metal... manufacturing fabricated metal products, such as fire or burglary resistive steel safes and vaults and similar... in fabricating iron and steel or other metal for structural purposes, such as bridges, buildings, and...
40 CFR Table 1 to Subpart Xxxxxx... - Description of Source Categories Affected by This Subpart
Code of Federal Regulations, 2010 CFR
2010-07-01
... (except springs) made from purchased wire. These facilities also manufacture steel balls; nonferrous metal... manufacturing fabricated metal products, such as fire or burglary resistive steel safes and vaults and similar... in fabricating iron and steel or other metal for structural purposes, such as bridges, buildings, and...
Miniature Six-Axis Load Sensor for Robotic Fingertip
NASA Technical Reports Server (NTRS)
Diftler, Myron A.; Martin, Toby B.; Valvo, Michael C.; Rodriguez, Dagoberto; Chu, Mars W.
2009-01-01
A miniature load sensor has been developed as a prototype of tactile sensors that could fit within fingertips of anthropomorphic robot hands. The sensor includes a force-and-torque transducer in the form of a spring instrumented with at least six semiconductor strain gauges. The strain-gauge wires are secured to one side of an interface circuit board mounted at the base of the spring. This board protects the strain-gauge wires from damage that could otherwise occur as a result of finger motions. On the opposite side of the interface board, cables routed along the neutral axis of the finger route the strain-gauge output voltages to an analog-to-digital converter (A/D) board. The A/D board is mounted as close as possible to the strain gauges to minimize electromagnetic noise and other interference effects. The outputs of the A/D board are fed to a controller, wherein, by means of a predetermined calibration matrix, the digitized strain-gauge output voltages are converted to three vector components of force and three of torque exerted by or on the fingertip.
A two-degrees-of-freedom miniature manipulator actuated by antagonistic shape memory alloys
NASA Astrophysics Data System (ADS)
Lai, Chih-Ming; Chu, Cheng-Yu; Lan, Chao-Chieh
2013-08-01
This paper presents a miniature manipulator that can provide rotations around two perpendicularly intersecting axes. Each axis is actuated by a pair of shape memory alloy (SMA) wires. SMA wire actuators are known for their large energy density and ease of actuation. These advantages make them ideal for applications that have stringent size and weight constraints. SMA actuators can be temperature-controlled to contract and relax like muscles. When correctly designed, antagonistic SMA actuators have a faster response and larger range of motion than bias-type SMA actuators. This paper proposes an antagonistic actuation model to determine the manipulator parameters that are required to generate sufficient workspace. Effects of SMA prestrain and spring stiffness on the manipulator are investigated. Taking advantage of proper prestrain, the actuator size can be made much smaller while maintaining the same motion. The use of springs in series with SMA can effectively reduce actuator stress. A controller and an anti-slack algorithm are developed to ensure fast and accurate motion. Speed, stress, and loading experiments are conducted to demonstrate the performance of the manipulator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
S.P. Cramer & Associates, Inc.
2002-05-31
We recently received data on the decoded coded wire tags (CWT's) recovered from spring chinook snouts we collected during spawning surveys in the Clearwater Basin last fall (2001). We were curious about what could be learned from the tags recovered (even though our project is over), so we did some cursory analyses and have described our findings in the attached memo. Snouts were processed and codes determined by Idaho Department of Fish and Game. Most snouts did not contain CWTs, because most ad-clipped fish were not given a CWT. Further, because adults were outplanted live, we do not know whatmore » codes they contained. Each of the hatcheries from which outplanted adults were obtained had several CWT code groups returning. That means that the best we can do with the codes recovered is compare the hatchery of origin for the tag with the hatchery from which outplants were taken. The results are interesting and not exactly as we would have predicted.« less
A clamp fixture with interdigital capacitive sensor for in situ evaluation of wire insulation
NASA Astrophysics Data System (ADS)
Sheldon, Robert T.; Bowler, Nicola
2014-02-01
An interdigital capacitive sensor has been designed and optimized for testing aircraft wires by applying a quasinumerical model developed and reported previously. The sensor consists of two patches of interdigitated electrodes, connected by a long signal bus strip, that are intended to conform to two sides of an insulated wire. The electrodes are deposited using photolithography upon a 25.4-μm-thick Kapton® polyimide film. The two electrode patches are attached to the two jaws of a plastic spring-loaded clamp, with each jaw having a milled groove designed such that the electrodes conform to the curved surface of the insulated wire. An SMA connector and cable connect between the electrodes on the clamp and an LCR meter. Segments of pristine M5086/2 aircraft wire, each 10 cm long, were immersed in fluids commonly found in aircraft environments, to cause accelerated chemical degradation. The effects of Jet A fuel, deicing fluid, hydraulic fluid, aircraft cleaner, isopropyl alcohol and distilled water were studied. The frequency-dependent capacitance and dissipation factor of one pristine wire segment and of those degraded in the six fluid environments were measured within the frequency range 100 Hz to 1 MHz. Significant changes in capacitance and dissipation factor were observed for all degraded wires, compared with results for the pristine sample, suggesting the feasibility of detecting insulation degradation in the field. The results were also consistent with those of a similar experiment performed on sheets of Nylon 6, the material that comprises the outermost layer of M5086/2 wire.
The spring migration of adult North American Ospreys
Martell, Mark S.; Bierregaard, Richard O.; Washburn, Brian E.; Elliott, John E.; Henny, Charles J.; Kennedy, Robert S.; MacLeod, Iain
2014-01-01
Most North American Ospreys (Pandion haliaetus) are migratory, breeding in northern latitudes and migrating long distances to and from their wintering grounds in the tropics. Although fall migration patterns of North American Ospreys have been described and studied, very little has been published about the spring migration of these birds. We used satellite telemetry to: (1) determine the characteristics (timing, duration, migratory routes) of spring migrations of Ospreys; (2) determine if differences in spring migration patterns existed between sexes and among three breeding populations (east coast, midwestern, and western); and (3) compare consecutive fall and spring migrations of individual Ospreys. The median dates for departure from the wintering grounds and arrival on the breeding grounds did not differ significantly between adult male and female Ospreys. Compared to their fall migrations, all male and all east coast Ospreys spent fewer days on migration, fewer days in stopover periods along the migration route, traveled shorter distances overall, and traveled farther (on average) each day during spring. In contrast, fall and spring migration characteristics of all female and western Ospreys were similar. Our findings suggest that, although sex and breeding location might influence the spring migration strategy used by individual Ospreys, both males and females minimize the time spent on migration to ensure a timely arrival on the breeding grounds to establish or defend a nesting territory.
Correlating electronic transport to atomic structures in self-assembled quantum wires.
Qin, Shengyong; Kim, Tae-Hwan; Zhang, Yanning; Ouyang, Wenjie; Weitering, Hanno H; Shih, Chih-Kang; Baddorf, Arthur P; Wu, Ruqian; Li, An-Ping
2012-02-08
Quantum wires, as a smallest electronic conductor, are expected to be a fundamental component in all quantum architectures. The electronic conductance in quantum wires, however, is often dictated by structural instabilities and electron localization at the atomic scale. Here we report on the evolutions of electronic transport as a function of temperature and interwire coupling as the quantum wires of GdSi(2) are self-assembled on Si(100) wire-by-wire. The correlation between structure, electronic properties, and electronic transport are examined by combining nanotransport measurements, scanning tunneling microscopy, and density functional theory calculations. A metal-insulator transition is revealed in isolated nanowires, while a robust metallic state is obtained in wire bundles at low temperature. The atomic defects lead to electron localizations in isolated nanowire, and interwire coupling stabilizes the structure and promotes the metallic states in wire bundles. This illustrates how the conductance nature of a one-dimensional system can be dramatically modified by the environmental change on the atomic scale. © 2012 American Chemical Society
Assessment of spring cranioplasty biomechanics in sagittal craniosynostosis patients.
Borghi, Alessandro; Schievano, Silvia; Rodriguez Florez, Naiara; McNicholas, Roisin; Rodgers, Will; Ponniah, Allan; James, Greg; Hayward, Richard; Dunaway, David; Jeelani, N U Owase
2017-11-01
OBJECTIVE Scaphocephaly secondary to sagittal craniosynostosis has been treated in recent years with spring-assisted cranioplasty, an innovative approach that leverages the use of metallic spring distractors to reshape the patient skull. In this study, a population of patients who had undergone spring cranioplasty for the correction of scaphocephaly at the Great Ormond Street Hospital for Children was retrospectively analyzed to systematically assess spring biomechanical performance and kinematics in relation to spring model, patient age, and outcomes over time. METHODS Data from 60 patients (49 males, mean age at surgery 5.2 ± 0.9 months) who had received 2 springs for the treatment of isolated sagittal craniosynostosis were analyzed. The opening distance of the springs at the time of insertion and removal was retrieved from the surgical notes and, during the implantation period, from planar radiographs obtained at 1 day postoperatively and at the 3-week follow-up. The force exerted by the spring to the patient skull at each time point was derived after mechanical testing of each spring model-3 devices with the same geometry but different wire thicknesses. Changes in the cephalic index between preoperatively and the 3-week follow-up were recorded. RESULTS Stiffer springs were implanted in older patients (p < 0.05) to achieve the same opening on-table as in younger patients, but this entailed significantly different-higher-forces exerted on the skull when combinations of stiffer springs were used (p < 0.001). After initial force differences between spring models, however, the devices all plateaued. Indeed, regardless of patient age or spring model, after 10 days from insertion, all the devices were open. CONCLUSIONS Results in this study provide biomechanical insights into spring-assisted cranioplasty and could help to improve spring design and follow-up strategy in the future.
Deployable robotic woven wire structures and joints for space applications
NASA Technical Reports Server (NTRS)
Shahinpoor, MO; Smith, Bradford
1991-01-01
Deployable robotic structures are basically expandable and contractable structures that may be transported or launched to space in a compact form. These structures may then be intelligently deployed by suitable actuators. The deployment may also be done by means of either airbag or spring-loaded typed mechanisms. The actuators may be pneumatic, hydraulic, ball-screw type, or electromagnetic. The means to trigger actuation may be on-board EPROMS, programmable logic controllers (PLCs) that trigger actuation based on some input caused by the placement of the structure in the space environment. The actuation may also be performed remotely by suitable remote triggering devices. Several deployable woven wire structures are examined. These woven wire structures possess a unique form of joint, the woven wire joint, which is capable of moving and changing its position and orientation with respect to the structure itself. Due to the highly dynamic and articulate nature of these joints the 3-D structures built using them are uniquely and highly expandable, deployable, and dynamic. The 3-D structure naturally gives rise to a new generation of deployable three-dimensional spatial structures.
Characterization and application of Shape Memory Alloy wires for micro and meso positioning systems
NASA Astrophysics Data System (ADS)
Khan, Afzal
The properties of Shape Memory Alloy (SMA) wires are determined by experimentation, and previously used experimental equipment contributes to measurement errors in data. In this study, various characterization experiments are designed and carried out using a precision characterization instrument for shape memory alloy wires to determine the properties and parameters of the alloy. These experiments demonstrate the behavior of SMA wires under different thermal and loading conditions as they occur in actuation applications. As SMA wires go through phase transformation, a significant amount of contraction force is produced. This actuation force has been used in bias spring actuators and differential actuators. In this dissertation, the force generated during the twinning of martensite is used to actuate positioning systems with small displacements at the micrometer level. A micropositioning system is designed and tested that has a positioning accuracy of about +/-0.15 mum. A relation between the current input and the displacement output is determined for the specific preload. The transformation force generated during the phase change from martensite to austenite is used as an actuation force for a second positioning system that uses linear bearing with a displacement range of about a millimeter. This positioning system actuated with a single nitinol wire and guided by symmetric parallel diaphragm flexures, was designed and tested. The actuation is repeatable to about +/-15 mum with variation of about +/-5 mum in postion at steady temperature.
Lower incisor intrusion with intraoral transosseous stainless steel wire anchorage in rabbits.
Wu, Jian-chao; Huang, Ji-na; Lin, Xin-ping
2010-06-01
The purpose of this research was to investigate the potential use of intraoral transosseous stainless steel wires as anchorage for intrusion of the lower incisors using a rabbit model. Placement of intraoral transosseous stainless steel wires around incisors is similar to that of intraoral transosseous wiring of edentulous mandibular fractures. Ten male New Zealand rabbits, 9 +/- 1.5 months of age, average weight 1.8 +/- 0.3 kg, were used in this study. One lower incisor was intruded with a 50 g bilateral force using a coil spring for 10 weeks, while the other incisor served as the control. Clinical measurements of the distances between the occlusal edges of the incisors (EE) were performed weekly with a calliper. In addition to standard descriptive statistical calculations, a paired Student's t-test was used for comparison of the two groups. All surgical sites healed uneventfully after insertion of the wires. Significant differences were found in the change of EE between the experimental and control sides from 4 weeks onwards. Intrusion of the incisor, 4 +/- 0.58 mm, was seen on the test side, while EE on the control side remained unchanged. Within the limits of this animal study, it is concluded that the intraoral transosseous stainless steel wire anchorage system is a cost-effective method for intrusion of lower incisors when the use of other anchorage system is not possible.
Design of automatic rotor blades folding system using NiTi shape memory alloy actuator
NASA Astrophysics Data System (ADS)
Ali, M. I. F.; Abdullah, E. J.
2016-10-01
This present paper will study the requirements for development of a new Automatic Rotor Blades Folding (ARBF) system that could possibly solve the availability, compatibility and complexity issue of upgrading a manual to a fully automatic rotor blades folding system of a helicopter. As a subject matter, the Royal Malaysian Navy Super Lynx Mk 100 was chosen as the baseline model. The aim of the study was to propose a design of SMART ARBF's Shape Memory Alloy (SMA) actuator and proof of operating concept using a developed scale down prototype model. The performance target for the full folding sequence is less than ten minutes. Further analysis on design requirements was carried out, which consisted of three main phases. Phase 1 was studying the SMA behavior on the Nickel Titanium (NiTi) SMA wire and spring (extension type). Technical values like activation requirement, contraction length, and stroke- power and stroke-temperature relationship were gathered. Phase 2 was the development of the prototype where the proposed design of stepped-retractable SMA actuator was introduced. A complete model of the SMART ARBF system that consisted of a base, a main rotor hub, four main rotor blades, four SMA actuators and also electrical wiring connections was fabricated and assembled. Phase 3 was test and analysis whereby a PINENG-PN968s-10000mAh Power Bank's 5 volts, which was reduced to 2.5 volts using LM2596 Step-Down Converter, powered and activated the NiTi spring inside each actuator. The bias spring (compression type), which functions to protract and push the blades to spread position, will compress together with the retraction of actuators and pull the blades to the folding position. Once the power was removed and SMA spring deactivated, the bias spring stiffness will extend the SMA spring and casing and push the blades back to spread position. The timing for the whole revolution was recorded. Based on the experimental analysis, the recorded timing for folding sequence is 2.5 minutes in average and therefore met the required criteria.
Colleges Question Data Used by "Yahoo!" To Rank the "Most Wired" Campus.
ERIC Educational Resources Information Center
Young, Jeffrey R.
1997-01-01
College administrators are complaining that "Yahoo! Internet Life" magazine used a flawed surveying process and inaccurate data to select the institutions it named in a recent ranking of "American's 100 Most Wired Colleges." Even some institutions faring well in the ranking have concerns about the survey, citing problems with…
33 CFR 164.76 - Towline and terminal gear for towing alongside and pushing ahead.
Code of Federal Regulations, 2010 CFR
2010-07-01
... towing alongside and pushing ahead. 164.76 Section 164.76 Navigation and Navigable Waters COAST GUARD... Towline and terminal gear for towing alongside and pushing ahead. The owner, master, or operator of each vessel towing alongside or pushing ahead shall ensure that the face wires, spring lines, and push gear...
46 CFR 160.156-5 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., Standard Specification for Carbon Structural Steel, (approved May 15, 2008), IBR approved for §§ 160.156-7 and 160.156-15 (“ASTM A 36”). (2) ASTM A 276-08a, Standard Specification for Stainless Steel Bars and..., (approved October 1, 2008), Standard Specification for Stainless Steel Spring Wire, IBR approved for § 160...
46 CFR 160.156-5 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., Standard Specification for Carbon Structural Steel, (approved May 15, 2008), IBR approved for §§ 160.156-7 and 160.156-15 (“ASTM A 36”). (2) ASTM A 276-08a, Standard Specification for Stainless Steel Bars and..., (approved October 1, 2008), Standard Specification for Stainless Steel Spring Wire, IBR approved for § 160...
46 CFR 160.156-5 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 36M-08, Standard Specification for Carbon Structural Steel, (approved May 15, 2008), IBR approved for §§ 160.156-7 and 160.156-15 (“ASTM A 36”). (2) ASTM A 276-08a, Standard Specification for Stainless Steel... 313/A 313M-08, (approved October 1, 2008), Standard Specification for Stainless Steel Spring Wire, IBR...
Ridley, Taylor J; Freking, Will; Erickson, Lauren O; Ward, Christina Marie
2017-07-01
To determine whether there is a difference in the incidence of infection between exposed and buried K-wires when used to treat phalangeal, metacarpal, and distal radius fractures. We conducted a retrospective review identifying all patients aged greater than 16 years who underwent fixation of phalangeal, metacarpal, or distal radius fractures with K-wires between 2007 and 2015. We recorded patient demographic data, fracture location, number of K-wires used, whether K-wires were buried or left exposed, and duration of K-wire placement. A total of 695 patients met inclusion criteria. Surgeons buried K-wires in 207 patients and left K-wires exposed in 488. Infections occurred more frequently in exposed K-wire cases than in buried K-wire ones. Subgroup analysis based on fracture location revealed a significantly increased risk of being treated for infection when exposed K-wires were used for metacarpal fractures. Patients with exposed K-wires for fixation of phalangeal, metacarpal, or distal radius fractures were more likely to be treated for a pin-site infection than those with K-wires buried beneath the skin. Metacarpal fractures treated with exposed K-wires were 2 times more likely to be treated for a pin-site infection (17.6% of exposed K wire cases vs 8.7% of buried K wire cases). Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-06
... accepted forms of payment are Visa, MasterCard, American Express, Discover, wire transfers and Automated.... currency, by VISA, MasterCard, American Express, and Discover. Cardholder's name, charge card number...
The saltiest springs in the Sierra Nevada, California
Moore, James G.; Diggles, Michael F.; Evans, William C.; Klemic, Karin
2017-07-20
The five saltiest springs in the Sierra Nevada in California are found between 38.5° and 38.8° N. latitude, on the South Fork American River; on Caples Creek, a tributary of the Silver Fork American River; and on the North Fork Mokelumne River. The springs issue from Cretaceous granitic rocks in the bottoms of these major canyons, between 1,200- and 2,200-m elevation. All of these springs were well known to Native Americans, who excavated meter-sized basins in the granitic rock, within which they produced salt by evaporation near at least four of the five spring sites. The spring waters are dominated by Cl, Na, and Ca; are enriched relative to seawater in Ca, Li, and As; and are depleted in SO4, Mg, and K. Tritium analyses indicate that the spring waters have had little interaction with rainfall since about 1954. The waters are apparently an old groundwater of meteoric origin that resided at depth before moving up along fractures to the surface of the exhumed granitic rocks. However, along the way these waters incorporated salts from depth, the origin of which could have been either from marine sedimentary rocks intruded by the granitic magmas or from fluid inclusions in the granitic rocks. Prolonged storage at depth fostered water-rock interactions that undoubtedly modified the fluid compositions.
Ghazal, Abdul Razzak A; Hajeer, Mohammad Y; Al-Sabbagh, Rabab; Alghoraibi, Ibrahim; Aldiry, Ahmad
2015-01-01
This study aimed to compare superelastic and heat-activated nickel-titanium orthodontic wires' surface morphology and potential release of nickel ions following exposure to oral environment conditions. Twenty-four 20-mm-length distal cuts of superelastic (NiTi Force I®) and 24 20-mm-length distal cuts of heat-activated (Therma-Ti Lite®) nickel-titanium wires (American Orthodontics, Sheboygan, WI, USA) were divided into two equal groups: 12 wire segments left unused and 12 segments passively exposed to oral environment for 1 month. Scanning electron microscopy and atomic force microscopy were used to analyze surface morphology of the wires which were then immersed in artificial saliva for 1 month to determine potential nickel ions' release by means of atomic absorption spectrophotometer. Heat-activated nickel-titanium (NiTi) wires were rougher than superelastic wires, and both types of wires released almost the same amount of Ni ions. After clinical exposure, more surface roughness was recorded for superelastic NiTi wires and heat-activated NiTi wires. However, retrieved superelastic NiTi wires released less Ni ions in artificial saliva after clinical exposure, and the same result was recorded regarding heat-activated wires. Both types of NiTi wires were obviously affected by oral environment conditions; their surface roughness significantly increased while the amount of the released Ni ions significantly declined.
Influences on lifetime of wire ropes in traction lifts
NASA Astrophysics Data System (ADS)
Vogel, W.
2016-05-01
Traction lifts are complex systems with rotating and translating moving masses, springs and dampers and several system inputs from the lifts and the users. The wire ropes are essential mechanical elements. The mechanical properties of the ropes in use depend on the rope construction, the load situation, nonlinearities and the lift dimensions. The mechanical properties are important for the proper use in lifts and the ride quality. But first of all the wire ropes (for all other suspension means as well) have to satisfy the safety relevant requirements sufficient lifetime, reliable determination of discard and sufficient and limited traction capacity. The lifetime of the wire ropes better the number of trips until rope discard depends on a lot of parameters of the rope and the rope application eg use of plastic deflection sheaves and reverse bending layouts. New challenges for rope lifetime are resulting from the more or less open D/d-ratio limits possible by certificates concerning the examination of conformity by notified bodies. This paper will highlight the basics of wire rope technology, the endurance and lifetime of wire ropes running over sheaves, and the different influences from the ropes and more and more important from the lift application parameters. Very often underestimated are the influences of transport, storage, installation and maintenance. With this background we will lead over to the calculation methods of wire rope lifetime considering the actual findings of wire rope endurance research. We'll show in this paper new and innovative facts as the influence of rope length and size factor in the lifetime formular, the reduction of lifetime caused by traction grooves, the new model for the calculation in reverse bending operations and the statistically firmed possibilities for machine roomless lifts (MRL) under very small bending conditions.
Advances and Environmental Conditions of Spring Migration Phenology of American White Pelicans
NASA Astrophysics Data System (ADS)
King, D. Tommy; Wang, Guiming; Yang, Zhiqiang; Fischer, Justin W.
2017-01-01
Spring migration phenology of birds has advanced under warming climate. Migration timing of short-distance migrants is believed to be responsive to environmental changes primarily under exogenous control. However, understanding the ecological causes of the advancement in avian spring migration phenology is still a challenge due to the lack of long-term precise location data. We used 11 years of Global Positioning System relocation data to determine four different migration dates of the annual migration cycle of the American white pelican (Pelecanus erythrorhynchos), a short-distance migrant. We also tested the hypothesis that increases in winter temperature and precipitation on the wintering grounds would advance pelican spring migration. Pelican spring departures and arrivals advanced steadily from 2002 to 2011. Spring departure timing exhibited high repeatability at the upper end of migration timing repeatability reported in literature. However, individual spring departure and arrival dates were not related to winter daily temperature, total winter precipitation, and detrended vegetation green-up dates indexed by the normalized difference vegetation index. Despite high repeatability, the observed between-year variation of spring departure dates was still sufficient for the advancement of spring departure timing.
Advances and Environmental Conditions of Spring Migration Phenology of American White Pelicans.
King, D Tommy; Wang, Guiming; Yang, Zhiqiang; Fischer, Justin W
2017-01-16
Spring migration phenology of birds has advanced under warming climate. Migration timing of short-distance migrants is believed to be responsive to environmental changes primarily under exogenous control. However, understanding the ecological causes of the advancement in avian spring migration phenology is still a challenge due to the lack of long-term precise location data. We used 11 years of Global Positioning System relocation data to determine four different migration dates of the annual migration cycle of the American white pelican (Pelecanus erythrorhynchos), a short-distance migrant. We also tested the hypothesis that increases in winter temperature and precipitation on the wintering grounds would advance pelican spring migration. Pelican spring departures and arrivals advanced steadily from 2002 to 2011. Spring departure timing exhibited high repeatability at the upper end of migration timing repeatability reported in literature. However, individual spring departure and arrival dates were not related to winter daily temperature, total winter precipitation, and detrended vegetation green-up dates indexed by the normalized difference vegetation index. Despite high repeatability, the observed between-year variation of spring departure dates was still sufficient for the advancement of spring departure timing.
VIEW NORTH EXTREME LEFTBUILDING 32; MACHINE SHOP (1890) SECOND LEFTBUILDING ...
VIEW NORTH- EXTREME LEFT-BUILDING 32; MACHINE SHOP (1890) SECOND LEFT-BUILDING 31; RIGGER SHOP (1890) CENTER- BUILDING 28; BLACKSMITH SHOP (1885) CENTER RIGHT-BUILDING 27; PATTERN SHOP (C.1853) RIGHT-BUILDING 40; WIRE WAREHOUSE (1915) - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
46 CFR 120.340 - Cable and wiring requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for the circuit in which they are used; (2) Be installed in a manner to avoid or reduce interference... paragraph (b)(8) of this section. (c) Conductors in power and lighting circuits must be No. 14 American Wire Gauge (AWG) or larger. Conductors in control and indicator circuits must be No. 22 AWG or larger. (d...
46 CFR 120.340 - Cable and wiring requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... for the circuit in which they are used; (2) Be installed in a manner to avoid or reduce interference... paragraph (b)(8) of this section. (c) Conductors in power and lighting circuits must be No. 14 American Wire Gauge (AWG) or larger. Conductors in control and indicator circuits must be No. 22 AWG or larger. (d...
46 CFR 120.340 - Cable and wiring requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... for the circuit in which they are used; (2) Be installed in a manner to avoid or reduce interference... paragraph (b)(8) of this section. (c) Conductors in power and lighting circuits must be No. 14 American Wire Gauge (AWG) or larger. Conductors in control and indicator circuits must be No. 22 AWG or larger. (d...
46 CFR 120.340 - Cable and wiring requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for the circuit in which they are used; (2) Be installed in a manner to avoid or reduce interference... paragraph (b)(8) of this section. (c) Conductors in power and lighting circuits must be No. 14 American Wire Gauge (AWG) or larger. Conductors in control and indicator circuits must be No. 22 AWG or larger. (d...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
... Memorial Drive, Kansas City, Missouri 64198-0001: 1. Larry L. Bingham, Baxter Springs, Kansas; Ross C. Hartley, Teton Village, Wyoming; Fred Mitchelson, Pittsburg, Kansas; and Bob L. Robinson, Baxter Springs... American Bank of Baxter Springs, both of Baxter Springs, Kansas. Board of Governors of the Federal Reserve...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
... choose the duty rate during customs entry procedures that applies to fuel rod assemblies (duty rate--3.3... plates; channels; spacers; end caps; springs; top and bottom nozzles; cages; guide tubes; and tubes, bar stocks, wires and plates of zirconium (duty rate ranges from 3.3 to 3.7%). Public comment is invited from...
A Simple Experiment for Determining the Elastic Constant of a Fine Wire
ERIC Educational Resources Information Center
Freeman, W. Larry; Freda, Ronald F.
2007-01-01
Many general physics laboratories involve the use of springs to demonstrate Hooke's law, and much ado is made about how this can be used as a model for describing the elastic characteristics of materials at the molecular or atomic level. In recent years, the proliferation of computers, and appropriate sensors, have made it possible to demonstrate…
Los Rios Community College District. Spring 1999 Student Profile, Based upon First Census Data.
ERIC Educational Resources Information Center
Glyer-Culver, Betty
This report, the second in a series based upon the official Spring First Census, provides data on student demographics and enrollment trends from spring 1994 to spring 1999 for the three colleges in California's Los Rios Community College District: American River College, Cosumnes River College, and Sacramento City College. For the first time, the…
True-3D Strain Mapping for Assessment of Material Deformation by Synchrotron X-Ray Microtomography
NASA Astrophysics Data System (ADS)
Ahn, J. J.; Toda, H.; Niinomi, M.; Kobayashi, T.; Akahori, T.; Uesugi, K.
2005-04-01
Downsizing of products with complex shapes has been accelerated thanks to the rapid development of electrodevice manufacturing technology. Micro electromechanical systems (MEMS) are one of such typical examples. 3D strain measurement of such miniature products is needed to ensure their reliability. In the present study, as preliminary trial for it 3D tensile deformation behavior of a pure aluminum wire is examined using the synchrotron X-ray microtomography technique at Spring-8, Japan. Multipurpose in-situ tester is used to investigate real-time tensile deformation behavior of the Al wire. Tensile tests are carried out under strokes of 0, 0.005, 0.01 and 0.015mm. It measures 3D local deformation of a region of interest by tracking a relative movement of a pair of particles at each point. Local deformation behavior of the Al wire is identified to be different from macroscopic deformation behavior. It may be closely associated with underlying microstructure.
True-3D Strain Mapping for Assessment of Material Deformation by Synchrotron X-Ray Microtomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahn, J.J.; Toda, H.; Niinomi, M.
2005-04-09
Downsizing of products with complex shapes has been accelerated thanks to the rapid development of electrodevice manufacturing technology. Micro electromechanical systems (MEMS) are one of such typical examples. 3D strain measurement of such miniature products is needed to ensure their reliability. In the present study, as preliminary trial for it 3D tensile deformation behavior of a pure aluminum wire is examined using the synchrotron X-ray microtomography technique at Spring-8, Japan. Multipurpose in-situ tester is used to investigate real-time tensile deformation behavior of the Al wire. Tensile tests are carried out under strokes of 0, 0.005, 0.01 and 0.015mm. It measuresmore » 3D local deformation of a region of interest by tracking a relative movement of a pair of particles at each point. Local deformation behavior of the Al wire is identified to be different from macroscopic deformation behavior. It may be closely associated with underlying microstructure.« less
Modeling and Evaluation of Canted Coil Springs as High Temperature Seal Preloading Devices
NASA Technical Reports Server (NTRS)
Oswald, Jay J.; Mullen, Robert L.; Dunlap, Patrick H., Jr.; Steinetz, Bruce M.
2004-01-01
Future reusable launch vehicles will require advanced structural seals. This includes propulsion seals along edges and hinge lines in hypersonic engines, and control surface seals for movable flaps and elevons on proposed reentry vehicles. Seals must remain in sealing engagement with opposing surfaces, for multiple missions, even though the seal gap may be opening and closing due to thermal and structural loads. To meet this requirement either the seals themselves must be resilient or there must be a resilient structural element behind the seals. Case Western Reserve University is working with NASA s Glenn Research Center to develop more resilient high temperature seal components and preloading devices. Results are presented for a finite element analysis of a canted coil spring that is being considered as a high temperature seal preloading device. This type of spring is a leading candidate due to its ability to provide nearly constant force over a large deflection. The finite element analyses were verified by comparing them to experimental results of canted coil springs of three different stiffnesses, measured at Glenn Research Center. Once validated the parameterized model was combined with a scripting algorithm to assess the effects of key spring design variables (wire diameter, coils per inch, cant amplitude, eccentricity, and spring width) on spring stiffness and maximum Von Mises stress to aid in subsequent design.
Beckman, B.R.; Dickhoff, Walton W.; Zaugg, W.S.; Sharpe, C.; Hirtzel, S.; Schrock, R.; Larsen, D.A.; Ewing, R.D.; Palmisano, A.; Schreck, C.B.; Mahnken, C.V.W.
1999-01-01
The relationship between smoltification and smolt-to-adult return (SAR) of spring chinook salmon Oncorhynchus tshawytscha from the Deschutes River, Oregon, was examined for four release groups in each of three successive years. Fish were reared, marked with coded wire tags, and released from Round Butte Hatchery, Pelton Ladder rearing facility, and Warm Springs National Fish Hatchery. Smolt releases occurred in nearly the same place at similar times, allowing a direct comparison of SAR to several characters representing smolt quality. Return rates varied significantly among facilities, varying over an order of magnitude each year. The highest average SAR was from Pelton Ladder, the lowest was from Warm Springs. Each of the characters used as metrics of smoltification - fish size, spring growth rate (February-April), condition factor, plasma hormone concentration (thyroxine, cortisol, and insulin-like growth factor-I [IGF-I]), stress challenge, gill Na+,K+-ATPase activity, and liver glycogen concentration - varied significantly among facilities and seasonally within hatchery groups. However, only spring growth rate, gill ATPase activity, and plasma IGF-I concentration showed significant relationships to SAR. These characters and SAR itself were consistently lower for fish released from Warm Springs Hatchery than for fish from Round Butte Hatchery and Pelton Ladder. This demonstrates that differences in the quality of fish released by facilities may have profound effects on subsequent survival and suggests that manipulations of spring growth rate may be used to influence the quality of smolts released from facilities.
Annual Coded Wire Tag Program; Oregon Missing Production Groups, 1997 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Mark A.; Mallette, Christine; Murray, William M.
1998-03-01
This annual report is in fulfillment of contract obligations with Bonneville Power Administration which is the funding source for the Oregon Department of Fish and Wildlife's Annual Coded Wire Tag Program - Oregon Missing Production Groups Project. Tule stock fall chinook were caught primarily in British Columbia and Washington ocean, and Oregon freshwater fisheries. Up-river bright stock fall chinook contributed primarily to Alaska and British Columbia ocean commercial, and Columbia River gillnet and other freshwater fisheries. Contribution of Rogue stock fall chinook released in the lower Columbia River occurred primarily in Oregon ocean commercial and Columbia river gillnet fisheries. Willamettemore » stock spring chinook contributed primarily to Alaska and British Columbia ocean commercial, Oregon freshwater sport and Columbia River gillnet fisheries. Willamette stock spring chinook released by CEDC contributed to similar ocean fisheries, but had much higher catch in gillnet fisheries than the same stocks released in the Willamette system. Up-river stocks of spring chinook contributed almost exclusively to Columbia River sport fisheries and other freshwater recovery areas. The up-river stocks of Columbia River summer steelhead contributed primarily to the Columbia River gillnet and other freshwater fisheries. Coho ocean fisheries from Washington to California were closed or very limited from 1994 through 1997 (1991 through 1994 broods). This has resulted in a greater average percent of catch for other fishery areas. Coho stocks released by ODFW below Bonneville Dam contributed mainly to Oregon and Washington ocean, Columbia Gillnet and other freshwater fisheries. Coho stocks released in the Klaskanine River and Youngs Bay area had similar ocean catch, but much higher contribution to gillnet fisheries than the other coho releases. Coho stocks released above Bonneville Dam had similar contribution to ocean fisheries as other coho releases. However, they contributed more to gillnet fisheries above Bonneville Dam than coho released below the dam. Survival rates of salmon and steelhead are influenced, not only by factors in the hatchery (disease, density, diet, size and time of release) but also by environmental factors in the river and ocean. These environmental factors are influenced by large scale weather patterns such as El Nino over which man has no influence. Changes in rearing conditions in the hatchery, over which man has some influence, do impact the survival rates. However, these impacts can be offset by impacts caused by environmental factors. Coho salmon released in the Columbia River generally experience better survival rates when released later in the spring. However, for the 1990 brood year June releases of Columbia River coho had much lower survival than May releases, for all ODFW hatcheries. In general survival of ODFW Columbia River hatchery coho has declined to low levels since the 1989 brood year. In an effort to evaluate photonic marking as a tool to mass mark salmonids, two groups of 1995 brood juvenile coho salmon were marked at Sandy Hatchery. The first group (Group A) received a fluorescent red mark, adipose fin clip and coded-wire tag. The second group (Group B) received a cryptic blue mark, adipose fin clip and coded-wire tag. Both groups were released in the spring of 1997. No photonic marks were detected in the precocious males (jacks) returning to Sandy hatchery in the fall of 1997.« less
USDA-ARS?s Scientific Manuscript database
Stem rust of wheat caused by the fungal pathogen Puccinia graminis f. sp. tritici historically caused major yield losses of wheat worldwide. To understand the genetic basis of stem rust resistance in conventional North American spring wheat, genome-wide association analysis (GWAS) was conducted on a...
Differences in the force system delivered by different beta-titanium wires in elaborate designs.
Martins, Renato Parsekian; Caldas, Sergei Godeiro Fernandes Rabelo; Ribeiro, Alexandre Antonio; Vaz, Luís Geraldo; Shimizu, Roberto Hideo; Martins, Lídia Parsekian
2015-01-01
Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.
Wosar, Marc A; Marcellin-Little, Denis J; Roe, Simon C
2002-01-01
To evaluate the effects of bolt torque, wire size, and component reuse on the ability to maintain wire tension in 3 external skeletal fixation systems. Biomechanical study. Yield strength in tension of 1.0-, 1.2-, 1.5-, and 1.6-mm-diameter wires, and yield strength in torque of Hofmann Small Bone Fixation (SBF) cannulated and slotted bolts and IMEX regular and miniature bolts were determined on a testing machine. The minimum bolt tightening torque needed to prevent wire slippage at clinically recommended wire tensions was determined. Components were tested 10 times, and loads at slippage were recorded. The IMEX system required a mean of 8 Nm of bolt tightening torque to maintain 900 N (1.6-mm wires). The SBF system required a mean of 3 Nm bolt torque to maintain 300 N (1.0-mm wires) and 5 Nm to maintain 600 N (1.2-mm wires). The SBF cannulated bolt required 9 Nm of torque to maintain 900 N (1.5-mm wires). The SBF slotted bolts could only maintain 800 N before yield. The IMEX miniature system required a mean bolt torque of 1.1 Nm to maintain 300 N. The cannulated and slotted bolts from both manufacturers failed to maintain 70% of initial wire tension after 7 and 4 uses, respectively. The IMEX systems and the SBF system using 1.0- and 1.2-mm wires could maintain clinically recommended wire tension safely. Only the IMEX system could maintain clinically recommended wire tension safely using 1.5- or 1.6-mm wires. The SBF system using 1.0- and 1.2-mm wires and the IMEX system using all wire sizes can maintain clinically relevant wire tension. The SBF system using 1.5-mm wires could not. Cannulated and slotted bolts should not be used more than 6 and 3 times, respectively. Nuts should not be reused. Copyright 2002 by The American College of Veterinary Surgeons
Memotain: A CAD/CAM nickel-titanium lingual retainer.
Kravitz, Neal D; Grauer, Dan; Schumacher, Pascal; Jo, Yong-Min
2017-04-01
Approximately 1/2 of maxillary and 1/5 of mandibular multi-stranded lingual retainers fail during retention in some form, either bond failure or wire breakage. Memotain is a new CAD/CAM fabricated lingual retainer wire made of custom-cut nickel-titanium, as an alternative to multi-stranded lingual retainers. It offers numerous perceived advantages to the traditional multi-stranded stainless steel wire, including precision fit, avoidance of interferences, corrosion resistance and even the potential for minor tooth movement as an active lingual retainer. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Barwart, O; Rollinger, J M; Burger, A
1999-10-01
Differential scanning calorimetry (DSC) was used to determine the transition temperature ranges (TTR) of four types of super-elastic orthodontic nickel-titanium coil springs (Sentalloy). A knowledge of the TTR provides information on the temperature at which a NiTi wire or spring can assume superelastic properties and when this quality disappears. The spring types in this study can be distinguished from each other by their characteristic TTR during cooling and heating. For each tested spring type a characteristic TTR during heating (austenite transformation) and cooling (martensite transformation) was evaluated. The hysteresis of the transition temperature, found between cooling and heating, was 3.4-5.2 K. Depending on the spring type the austenite transformation started (As) at 9.7-17.1 degrees C and finished (Af) at 29.2-37 degrees C. The martensite transformation starting temperature (Ms) was evaluated at 32.6-25.4 degrees C, while Mf (martensite transformation finishing temperature) was 12.7-6.5 degrees C. The results show that the springs become super-elastic when the temperature increases and As is reached. They undergo a loss of super-elastic properties and a rapid decrease in force delivery when they are cooled to Mf. For the tested springs, Mf and As were found to be below room temperature. Thus, at room temperature and some degrees lower, all the tested springs exert super-elastic properties. For orthodontic treatment this means the maintenance of super-elastic behaviour, even when mouth temperature decreases to about room temperature as can occur, for example, during meals.
Kalantar Motamedi, Mahmood Reza; Heidarpour, Majid; Siadat, Sara; Kalantar Motamedi, Alimohammad; Bahreman, Ali Akbar
2015-09-01
Extraction of mandibular third molars (M3s) in close proximity to the mandibular canal has some inherent risks to adjacent structures, such as neurologic damage to teeth, bone defects distal to the mandibular second molar (M2), or pathologic fractures in association with enlarged dentigerous cysts. The procedure for extrusion and subsequent extraction of high-risk M3s is called orthodontic extraction. This is a systematic review of the available approaches for orthodontic extraction of impacted mandibular M3s in close proximity to the mandibular canal and their outcomes. The PubMed, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), DOAJ, Google Scholar, OpenGrey, Iranian Science Information Database (SID), Iranmedex, and Irandoc databases were searched using specific keywords up to June 2, 2014. Studies were evaluated based on predetermined eligibility criteria, treatment approaches, and their outcomes. Thirteen articles met the inclusion criteria. A total of 123 impacted teeth were extracted by orthodontic extraction and 2 cases were complicated by transient paresthesia. Three types of biomechanical approaches were used: 1) using the posterior maxillary region as the anchor for orthodontic extrusion of lower M3s, 2) simple cantilever springs attached to the M3 buttonhole, and 3) cantilever springs tied to a bonded orthodontic bracket on the M3 plus multiple-loop spring wire for distal movement of the M3. Osteo-periodontal status of M2s also improved uneventfully. Despite the drawbacks of orthodontic extraction, removal of deeply impacted M3s using the described techniques is safe with regard to mandibular nerve injury and neurologic damage. Orthodontic extraction is recommended for extraction of impacted M3s that present a high risk of postoperative osteo-periodontal defects on the distal surface of the adjacent M2 and those associated with dentigerous cysts. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
2011-05-01
Quantum physics: German Physical Society spring meeting Journal access: American Physical Society's online journals will be available for free in all US high schools Award: High-school physics teacher receives American award for excellence Teacher training: Fobinet offers coordination of teacher-training activities Astronomy: Astronomy fans see stars at Astrofest Conference: Delegates enjoy the workshops and activities at CPD conference Forthcoming events
NASA Astrophysics Data System (ADS)
Jones, Christopher F.
2009-12-01
Coal canals, oil pipelines, and electricity transmission wires transformed the built environment of the American mid-Atlantic region between 1820 and 1930. By transporting coal, oil, and electrons cheaply, reliably, and in great quantities, these technologies reshaped the energy choices available to mid-Atlantic residents. In particular, canals, pipelines, and wires created new energy landscapes: systems of transport infrastructure that enabled the ever-increasing consumption of fossil fuels. Energy Landscapes integrates history of technology, environmental history, and business history to provide new perspectives on how Americans began to use fossil fuels and the social implications of these practices. First, I argue that the development of transport infrastructure played critical, and underappreciated, roles in shaping social energy choices. Rather than simply responding passively to the needs of producers and consumers, canals, pipelines, and wires structured how, when, where, and in what quantities energy was used. Second, I analyze the ways fossil fuel consumption transformed the society, economy, and environment of the mid-Atlantic. I link the consumption of coal, oil, and electricity to the development of an urban and industrialized region, the transition from an organic to a mineral economy, and the creation of a society dependent on fossil fuel energy.
Torsion fracture of carbon nanocoils
NASA Astrophysics Data System (ADS)
Yonemura, Taiichiro; Suda, Yoshiyuki; Tanoue, Hideto; Takikawa, Hirofumi; Ue, Hitoshi; Shimizu, Kazuki; Umeda, Yoshito
2012-10-01
We fix a carbon nanocoil (CNC) on a substrate in a focused ion beam instrument and then fracture the CNC with a tensile load. Using the CNC spring index, we estimate the maximum to average stress ratio on the fractured surface to range from 1.3 to 1.7, indicating stress concentration on the coil wire inner edge. Scanning electron microscopy confirms a hollow region on the inner edge of all fractured surfaces.
Passive Sun seeker/tracker and a thermally activated power module
NASA Technical Reports Server (NTRS)
Siebert, C. J.; Morris, F. A.
1984-01-01
Development and testing of two mechanisms using a shape memory alloy metal (NITINOL) as the power source are described. The two mechanisms developed are a passive Sun Seeker/Tracker and a generic type power module. These mechanisms use NITINOL wire initially strained in pure torsion which provides the greatest mechanical work capacity upon recovery, as compared to other deformation modes (i.e., tension, helical springs, and bending).
Electric Utility Industry Experience with Geomagnetic Disturbances
1991-09-01
the auroral electrojets or currents that result from solar-emitted particles during geomagnetic storms is provided by the aurora borealis , often called...on wire-based communication systems. As early as 1860 it was noted that during intense periods of the aurora borealis , telegraphic systems were... San Diego , CA 92186-5154. 221. Jaycor, M. Schultz, Jr., 1608 Spring Hill Road, Vienna, VA 22182-2270. 222. Joint Strategic Target Planning Staff, The
Code of Federal Regulations, 2013 CFR
2013-10-01
...; and (2) Nonmetallic flexible hose is acceptable if it— (i) Is used in lengths of not more than 0.76... reinforced with wire braid; and (v) Either,— (A) If it is designed for use with compression fittings, is... clamps at each end of the hose. Clamps must not rely on spring tension and must be installed beyond the...
Code of Federal Regulations, 2012 CFR
2012-10-01
...; and (2) Nonmetallic flexible hose is acceptable if it— (i) Is used in lengths of not more than 0.76... reinforced with wire braid; and (v) Either,— (A) If it is designed for use with compression fittings, is... clamps at each end of the hose. Clamps must not rely on spring tension and must be installed beyond the...
Code of Federal Regulations, 2011 CFR
2011-10-01
...; and (2) Nonmetallic flexible hose is acceptable if it— (i) Is used in lengths of not more than 0.76... reinforced with wire braid; and (v) Either,— (A) If it is designed for use with compression fittings, is... clamps at each end of the hose. Clamps must not rely on spring tension and must be installed beyond the...
Code of Federal Regulations, 2014 CFR
2014-10-01
...; and (2) Nonmetallic flexible hose is acceptable if it— (i) Is used in lengths of not more than 0.76... reinforced with wire braid; and (v) Either,— (A) If it is designed for use with compression fittings, is... clamps at each end of the hose. Clamps must not rely on spring tension and must be installed beyond the...
HIV-risk behaviours of American spring break vacationers: a case of situational disinhibition?
Apostolopoulos, Y; Sönmez, S; Yu, C H
2002-11-01
Young adults are at high risk for acquiring STDs/HIV due primarily to multiple sex partners, unprotected sex, and substance use combined with sexual activity. Contranormative settings--such as the annual spring break vacation--provide ideal conditions for the potentially lethal interaction between alcohol, drugs, and sexual risk-taking. As a steadily growing form of youth travel and characterized by binge drinking, illicit drug use, and unsafe sexual practices, spring break has become a North American institution involving large numbers of travellers. In this study, the theory of interpersonal behaviour was used to explain college students' health-risk behaviours in the context of spring break and pre- and post-spring break surveys were used to examine casual sex and condom use behaviours. Multivariate analyses revealed peer influences, prior experiences with casual sex, alcohol consumption prior to sex, and impulsivity to be significant predictors of casual sex, while impulsivity and condom availability were significant predictors of students' use of condoms during casual sex.
Ishida, Takayoshi; Ono, Takashi
2014-09-01
To describe the orthodontic treatment of a nongrowing 30-year-old woman with asymmetric severe skeletal Class II malocclusions (asymmetric Angle Class II), large overjet (16 mm), large overbite (8 mm), two congenitally missing mandibular incisors (presenting a deciduous anterior tooth), and signs and symptoms of temporomandibular joint disorder (TMD). We used novel improved super-elastic Ni-Ti alloy wires (ISWs) combined with Ni-Ti alloy coil springs, power hooks, and a zygomatic implant as reinforced anchorage to provide a constant and continuous mild force to the dentition. We successfully distalized maxillary molars, premolars, and retracted anterior teeth and corrected the asymmetric Angle Class II molar relationship using this system of zygomatic anchorage in conjunction with ISWs, Ni-Ti alloy open-coil springs, and crimpable power hook. The maxillary molars were distalized, and postero-occlusal relationships were improved to achieve Class I canine and molar relationships on both sides. Intrusion of the upper molars made the mandibular plane close. Ideal overbite and overjet relationships were established. Facial esthetics were improved with decreased upper and lower lip protrusion, and no symptoms of TMD were observed after treatment. The orthodontic treatment described here is a promising anchorage technique alternative to traditional techniques to improve severe skeletal Class II with TMD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-02-01
The Western Area Power Administration (Western) is proposing to rebuild, operate, and maintain a 115-kilovolt (kV) transmission line between the Big George and Carter Mountain Substations in northwest Wyoming (Park and Hot Springs Counties). This environmental assessment (EA) was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ) and the Department of Energy (DOE). The existing Big George to Carter Mountain 69-kV transmission line was constructed in 1941 by the US Department of Interior, Bureau of Reclamation, with 1/0 copper conductor on wood-pole H-frame structures without an overhead groundmore » wire. The line should be replaced because of the deteriorated condition of the wood-pole H-frame structures. Because the line lacks an overhead ground wire, it is subject to numerous outages caused by lightning. The line will be 54 years old in 1995, which is the target date for line replacement. The normal service life of a wood-pole line is 45 years. Under the No Action Alternative, no new transmission lines would be built in the project area. The existing 69-kV transmission line would continue to operate with routine maintenance, with no provisions made for replacement.« less
Spring-assisted posterior skull expansion without osteotomies.
Arnaud, Eric; Marchac, Alexandre; Jeblaoui, Yassine; Renier, Dominique; Di Rocco, Federico
2012-09-01
A posterior flatness of the skull vault can be observed in infants with brachycephaly. Such posterior deformation favours the development of turricephaly which is difficult to correct. To reduce the risk of such deformation, an early posterior skull remodelling has been suggested. Translambdoid springs can be used to allow for a distraction through the patent lambdoid sutures and obtain a progressive increase of the posterior skull volume. The procedure consists in a posterior scalp elevation, the patient being on a prone position. Springs made of stainless steel wire (1.5 mm in diameter) are bent in a U-type fashion, and strategically positioned across both lambdoid sutures. No drilling is usually necessary, as the lambdoid suture can be gently forced with a subperiosteal elevator in its middle and an indentation can be created with a bony rongeur on each side of the open suture to allow for a self-retention of bayonet-shaped extremity of the spring. Careful attention is addressed to the favoured prone position during the post-operative period. After a delay of 3-6 months, the springs can be removed during a second uneventful procedure, with limited incisions, usually as a preliminary step of the subsequent frontal remodelling. The concept of spring-assisted expansion across patent sutures under 6 months of age was confirmed in our experience (19 cases). Insertion of the springs allowed for immediate distraction across the suture. A posterior remodelling of the skull could be achieved with minimal morbidity allowing to delay safely a radical anterior surgery.
A cycloidal wobble motor driven by shape memory alloy wires
NASA Astrophysics Data System (ADS)
Hwang, Donghyun; Higuchi, Toshiro
2014-05-01
A cycloidal wobble motor driven by shape memory alloy (SMA) wires is proposed. In realizing a motor driving mechanism well known as a type of reduction system, a cycloidal gear mechanism is utilized. It facilitates the achievement of bidirectional continuous rotation with high-torque capability, based on its high efficiency and high reduction ratio. The applied driving mechanism consists of a pin/roller based annular gear as a wobbler, a cycloidal disc as a rotor, and crankshafts to guide the eccentric wobbling motion. The wobbling motion of the annular gear is generated by sequential activation of radially phase-symmetrically placed SMA wires. Consequently the cycloidal disc is rotated by rolling contact based cycloidal gearing between the wobbler and the rotor. In designing the proposed motor, thermomechanical characterization of an SMA wire biased by extension springs is experimentally performed. Then, a simplified geometric model for the motor is devised to conduct theoretical assessment of design parametric effects on structural features and working performance. With consideration of the results from parametric analysis, a functional prototype three-phase motor is fabricated to carry out experimental verification of working performance. The observed experimental results including output torque, rotational speed, bidirectional positioning characteristic, etc obviously demonstrate the practical applicability and potentiality of the wobble motor.
Orthodontic uprighting of severely impacted mandibular second molars.
Lau, Catherine K; Whang, Claudia Z Y; Bister, Dirk
2013-01-01
The prevalence of impacted second molars is low, varying from 0% to 2.3%. The etiology of an impaction can involve systemic, local, and periodontal factors, as well as a developmental disruption of the tooth germ. A number of surgical and orthodontic treatment options have been suggested in the literature, including leaving the tooth in situ, removing the impacted second molar, orthodontic uprighting, and autotransplantation. Removal of third molars has been suggested as an adjunct for space creation. This article presents the treatment of a girl with bilateral severely impacted mandibular second molars as well as an ectopic maxillary left canine and severe crowding affecting both the maxillary and mandibular arches. Her treatment was successfully completed with fixed preadjusted edgewise appliances (0.022 × 0.028-in slot size) and MBT prescription (APC precoated Gemini Brackets; 3M Unitek, St. Paul, Minn), along with the removal of 4 first premolars. The maxillary left canine and the mandibular second molars were surgically exposed. The treatment mechanics show that even severely impacted second molars can be uprighted by routine straight-wire techniques, which are easy to apply. The center of rotation of the second molar lies in the bifurcation of the roots of this tooth, and this biomechanical property was used to its full advantage. The techniques applied comprised bracket repositioning, bypass of brackets, conversion of molar tubes to brackets, thermoelastic copper-nickel-titanium archwires, and a push-coil spring. Other orthodontic treatment mechanics, which require complex sectional or segmental techniques, auxiliaries, or artistic wire bending, that have been suggested in the literature were not used here. The third molars were not removed. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Kerley, James J. (Inventor); Eklund, Wayne D. (Inventor)
1992-01-01
A device for holding reading materials for use by readers without arm mobility is presented. The device is adapted to hold the reading materials in position for reading with the pages displayed to enable turning by use of a rubber tipped stick that is held in the mouth and has a pair of rectangular frames. The frames are for holding and positioning the reading materials opened in reading posture with the pages displayed at a substantially unobstructed sighting position for reading. The pair of rectangular frames are connected to one another by a hinge so the angle between the frames may be varied thereby varying the inclination of the reading material. A pair of bent spring mounted wires for holding opposing pages of the reading material open for reading without substantial visual interference of the pages is mounted to the base. The wires are also adjustable to the thickness of the reading material and have a variable friction adjustment. This enables the force of the wires against the pages to be varied and permits the reader to manipulate the pages with the stick.
2011-09-01
Testing Input electrodes consisting of 1/2” diameter, 6” long copper rods were wired to separate conductors of a shielded, commercially available...underwater-rated electrical cable (three-conductor, shielded, shipboard cable (TSS-2), 18 American Wire Gauge (AWG) stranded copper ). Electrode pairs...sandpaper prior to use to ensure the best electrical continuity between the water and electrode by removing any copper oxide. This electrode
Prototype Morphing Fan Nozzle Demonstrated
NASA Technical Reports Server (NTRS)
Lee, Ho-Jun; Song, Gang-Bing
2004-01-01
Ongoing research in NASA Glenn Research Center's Structural Mechanics and Dynamics Branch to develop smart materials technologies for aeropropulsion structural components has resulted in the design of the prototype morphing fan nozzle shown in the photograph. This prototype exploits the potential of smart materials to significantly improve the performance of existing aircraft engines by introducing new inherent capabilities for shape control, vibration damping, noise reduction, health monitoring, and flow manipulation. The novel design employs two different smart materials, a shape-memory alloy and magnetorheological fluids, to reduce the nozzle area by up to 30 percent. The prototype of the variable-area fan nozzle implements an overlapping spring leaf assembly to simplify the initial design and to provide ease of structural control. A single bundle of shape memory alloy wire actuators is used to reduce the nozzle geometry. The nozzle is subsequently held in the reduced-area configuration by using magnetorheological fluid brakes. This prototype uses the inherent advantages of shape memory alloys in providing large induced strains and of magnetorheological fluids in generating large resistive forces. In addition, the spring leaf design also functions as a return spring, once the magnetorheological fluid brakes are released, to help force the shape memory alloy wires to return to their original position. A computerized real-time control system uses the derivative-gain and proportional-gain algorithms to operate the system. This design represents a novel approach to the active control of high-bypass-ratio turbofan engines. Researchers have estimated that such engines will reduce thrust specific fuel consumption by 9 percent over that of fixed-geometry fan nozzles. This research was conducted under a cooperative agreement (NCC3-839) at the University of Akron.
HighWire Free Online Full-text Articles
every Jan. Advances in Nutrition: An International Review Journal all articles after 12 months Advances American Journal of Botany all articles after 12 months The American Journal of Clinical Nutrition all Nutrition all articles after 12 months back to 1 Jan 1997 Journal of Oncology Practice all articles after 12
The Thermal Evaluation of Air-Cooled Electronic Equipment
1952-09-01
of Unit with Case-Envelope Heat Exchanger 233 VII-7 Storking Plot for Evaluation of Case Heat Transfer of Unit with Integrated or Separate... wing . 1. Case Cooled by Free Convection and Radiation Equipment of this type which depends on the natural heat dissipative capacity of the outer...described application, a tightly-fitting spring- clip is placed around the component, such as a tube, with the two thermocouple lead wires spot-welded
76 FR 7577 - Endangered and Threatened Species Permit Applications
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-10
.../absence surveys for the following species: Texas blind salamander (Typhlomolge rathbuni), Barton Springs salamander (Eurycea sosorum), Mexican long-nosed bat (Leptonycteris nivalis), American burying beetle... cupido attwateri) Barton Springs salamander (Eurycea sosorum) Bee Creek Cave harvestman (Texella reddelli...
Magnetic measurements of the 10 T superconducting wiggler for the SPring-8 storage ring
NASA Astrophysics Data System (ADS)
Batrakov, A.; Borovikov, V.; Bekhtenev, E.; Fedurin, M.; Hara, M.; Karpov, G.; Kuzin, M.; Mezentsev, N.; Miahara, Y.; Shimada, T.; Shkaruba, V.; Soutome, K.; Tzumaki, K.
2001-07-01
In 1999, in the frame of the project ISTC #767 "Budker INP/RIKEN Slow Positron Source", the Budker Institute of Nuclear Physics had made a 10 T Three-pole Superconducting Wiggler. The wiggler will be the keystone of this project by its installation on the SPring-8 storage ring for powerful gamma ray generation ( λ c=450 keV ), that will be used for slow positron production ( Nγ( ɛ>1 MeV)˜10 15, γ/s I e=0.1 A ). A. Ando et al., Proposal of the high magnetic field super conducting WLS for slow positron source at SPring-8, presented at SR1 '97 Conference. In January, 2000, the wiggler was transported to SPring-8, where the last test and measurements were carried out in collaboration with Japan. In this article, the results of measurements of the magnetic field, finding the magnetic field amplitude by an NMR probe, the definition of feed current relations by stretch current wire method, the calibration of a Hall probe in the high magnetic field, and the measurement of the magnetic field profile by a Hall probe are presented.
NASA Astrophysics Data System (ADS)
Akiyama, Terunobu; Staufer, Urs; Rooij, Nico F. de
2002-06-01
A microfabricated, electrical connector is proposed for facilitating the mounting of atomic force microscopy (AFM) probes, which have an integrated sensor and/or actuator. Only a base chip, which acts as a socket, is permanently fixed onto a printed circuit board and electronically connected by standard wire bonding. The AFM chip, the “plug”, is flipped onto the base chip and pressed from the backside by a spring. Electrical contact with the eventual stress sensors, capacitive or piezoelectric sensor/actuators, is provided by contact bumps. These bumps of about 8 μm height are placed onto the base chip. They touch the pads on the AFM chip that were originally foreseen to be for wire bonding and thus provide the electrical contact. This connector schema was successfully used to register AFM images with piezoresistive cantilevers.
Cleanliness of disposable vs nondisposable electrocardiography lead wires in children.
Addison, Nancy; Quatrara, Beth; Letzkus, Lisa; Strider, David; Rovnyak, Virginia; Syptak, Virginia; Fuzy, Lisa
2014-09-01
Mediastinitis costs hospitals thousands of dollars a year and increases the incidence of patient morbidity and mortality. No studies have been done to evaluate adenosine triphosphate (ATP) counts on disposable and nondisposable electrocardiography (ECG) lead wires in pediatric patients. To compare the cleanliness of disposable and nondisposable ECG lead wires in postoperative pediatric cardiac surgery patients by measuring the quantity of ATP (in relative luminescence units [RLUs]). ATP levels correlate with microbial cell counts and are used by institutions to assess hospital equipment and cleanliness. A prospective, randomized trial was initiated with approval from the institutional review board. Verbal consent was obtained from the parents/guardians for each patient. Trained nurses performed ATP swabs on the right and left upper ECG cables on postoperative days 1, 2, and 3. This study enrolled 51 patients. The disposable ECG lead wire ATP count on postoperative day 1 (median, 157 RLUs) was significantly lower (P < .001) than the count for nondisposable ATP lead wires (median, 610 RLUs). On postoperative day 2, the ATP count for the disposable ECG lead wires (median, 200 RLUs) was also lower (P = .06) than the count for the nondisposable ECG lead wires (median, 453 RLUs). Results of this study support the use of disposable ECG lead wires in postoperative pediatric cardiac surgery patients for at least the first 48 hours as a direct strategy to reduce the ATP counts on ECG lead wires. ©2014 American Association of Critical-Care Nurses.
New High: A Future-Oriented Study of American Drug Policy
2017-12-01
firearms Space travel Quantum computing Embodied intelligence augmentation Xenotransplantation Artificial intelligence CRISPR 3D printing...498 Office of National Drug Control Policy, National Drug Control Strategy, 32. 499 Amy Webb, “ Crispr Makes It Clear: The U.S...Needs a Biology Strategy, and Fast,” Wired, May 11, 2017, www.wired.com/2017/05/ crispr -makes-clear-US-needs-biology-strategy-fast/. 500 Ibid. 501
SMA spring-based artificial muscle actuated by hot and cool water using faucet-like valve
NASA Astrophysics Data System (ADS)
Park, Cheol Hoon; Son, Young Su
2017-04-01
An artificial muscle for a human arm-like manipulator with high strain and high power density are under development, and an SMA(Shape memory alloy) spring is a good actuator for this application. In this study, an artificial muscle composed of a silicon tube and a bundle of SMA(Shape memory alloy) springs is evaluated. A bundle of SMA springs consists of five SMA springs which are fabricated by using SMA wires with a diameter of 0.5 mm, and hot and cool water actuates it by heating and cooling SMA springs. A faucet-like valve was also developed to mix hot water and cool water and control the water temperature. The mass of silicon tube and a bundle of SMA springs is only 3.3 g and 2.25 g, respectively, and the total mass of artificial muscle is 5.55 g. It showed good actuating performance for a load with a mass of 2.3 kg and the power density was more than 800 W/kg for continuous valve switching with a cycle of 0.6 s. The faucet-like valve can switch a water output from hot water to cold water within 0.3s, and the artificial muscle is actuated well in response to the valve position and speed. It is also presented that the temperature of the mixed water can be controlled depending on the valve position, and the displacement of the artificial muscle can be controlled well by the mixed water. Based on these results, SMA spring-based artificial muscle actuated by hot and cool water could be applicable to the human arm-like robot manipulators.
The influence of bracket design on frictional losses in the bracket/arch wire system.
Schumacher, H A; Bourauel, C; Drescher, D
1999-01-01
In arch guided tooth movement, the essential role played by bracket configuration with respect to sliding friction has been recognized by the manufacturers, a fact which has had an increasing impact on the design and marketing of new bracket models in recent years. The aim of the present in-vitro study was to investigate the influence of different bracket designs on sliding mechanics. Five differently shaped stainless steel brackets (Discovery: Dentaurum, Damon SL: A-Company, Synergy: Rocky Mountain Orthodontics, Viazis bracket and Omni Arch appliance: GAC) were compared in the 0.022"-slot system. The Orthodontic Measurement and Simulation System (OMSS) was used to quantify the difference between applied force (NiTi coil spring, 1.0 N) and orthodontically effective force and to determine leveling losses occurring during the sliding process in arch guided tooth movement. Simulated canine retraction was performed using continuous arch wires with the dimensions 0.019" x 0.025" (Standard Steel, Unitek) and 0.020" x 0.020" (Ideal Gold, GAC). Comparison of the brackets revealed friction-induced losses ranging from 20 to 70%, with clear-cut advantages resulting from the newly developed bracket types. However, an increased tendency towards leveling losses in terms of distal rotation (maximum 15 degrees) or buccal root torque (maximum 20 degrees) was recorded, especially with those brackets giving the arch wire increased mobility due to their shaping or lack of ligature wire.
Kaliyadan, Antony G; Chawla, Harnish; Fischman, David L; Ruggiero, Nicholas; Gannon, Michael; Walinsky, Paul; Savage, Michael P
2017-02-01
This study assessed the impact of adjunct delivery techniques on the deployment success of distal protection filters in saphenous vein grafts (SVGs). Despite their proven clinical benefit, distal protection devices are underutilized in SVG interventions. Deployment of distal protection filters can be technically challenging in the presence of complex anatomy. Techniques that facilitate the delivery success of these devices could potentially improve clinical outcomes and promote greater use of distal protection. Outcomes of 105 consecutive SVG interventions with attempted use of a FilterWire distal protection device (Boston Scientific) were reviewed. In patients in whom filter delivery initially failed, the success of attempted redeployment using adjunct delivery techniques was assessed. Two strategies were utilized sequentially: (1) a 0.014" moderate-stiffness hydrophilic guidewire was placed first to function as a parallel buddy wire to support subsequent FilterWire crossing; and (2) if the buddy-wire approach failed, predilation with a 2.0 mm balloon at low pressure was performed followed by reattempted filter delivery. The study population consisted of 80 men and 25 women aged 73 ± 10 years. Mean SVG age was 14 ± 6 years. Complex disease (American College of Cardiology/American Heart Association class B2 or C) was present in 92%. Initial delivery of the FilterWire was successful in 82/105 patients (78.1%). Of the 23 patients with initial failed delivery, 8 (35%) had successful deployment with a buddy wire alone, 7 (30%) had successful deployment with balloon predilation plus buddy wire, 4 (17%) had failed reattempt at deployment despite adjunct maneuvers, and in 4 (17%) no additional attempts at deployment were made at the operator's discretion. Deployment failure was reduced from 21.9% initially to 7.6% after use of adjunct delivery techniques (P<.01). No adverse events were observed with these measures. Deployment of distal protection devices can be technically difficult with complex SVG disease. Adjunct delivery techniques are important to optimize deployment success of distal protection filters during SVG intervention.
Application of peer instruction in the laboratory task of measuring the effective mass of a spring
NASA Astrophysics Data System (ADS)
Zhang, Chun-Ling; Hou, Zhen-Yu; Si, Yu-Chang; Wen, Xiao-Qing; Tang, Lei
2017-11-01
Peer instruction (PI) is an effective interactive approach to teaching and learning that has principally been used to modify the experience of learning in traditional physics lecture settings. This article further illustrates how the concept of PI can be effectively applied in the physics student laboratory setting. The setting used is a laboratory task that calls for the measurement of the effective mass of the spring of a Jolly balance. Through PI the students gain a better understanding of what is meant by the construct ‘effective mass of a spring’, and thereby competently work out how the mass, shape, wire diameter, and number of turns of the spring can all affect the effective mass of the spring. Furthermore, using stopwatches the students were also able to appreciate how recorded times at the equilibrium position had greater uncertainty than measurements made at the maximum displacement. This led to their calculations of the effective mass of the spring being impressively close to the theoretical value. Such laboratory tasks are extremely challenging to introductory level students and the success attained by the students in this study indicates that there is much potential in the application of PI in laboratory settings. PI should be used to teach in the laboratory and results should be reported in order for our community to build on these experiences. This article is a contribution to that effort.
2011-03-01
Mile per hour ms Millisecond NEDU Navy Experimental Diving Unit PFD Personal flotation device PIW Person in the water PVC Polyvinyl chloride RDC...electrically resistive, yet conductive, clay. We then encapsulated the clay around a 1/2” diameter, 6-inch long copper rod, and then tightly wrapped it with...short length of 12 American Wire Gauge (AWG) stranded copper wire to the copper rod within each electrode. For each electrode pair, we joined
The Application of Ultrasonic Inspection to Crimped Electrical Connections
NASA Technical Reports Server (NTRS)
Cramer, K. Elliott; Perey, Daniel F.; Yost, William T.
2010-01-01
The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The development of a prototype instrument, based on a modified, commercially available, crimp tool, is demonstrated for applying this technique when wire crimps are installed. The crimp tool has three separate crimping locations that accommodate the three different ferrule diameters. The crimp tool in this study is capable of crimping wire diameters ranging from 12 to 26 American Wire Gauge (AWG). A transducer design is presented that allows for interrogation of each of the three crimp locations on the crimp tool without reconfiguring the device. An analysis methodology, based on transmitted ultrasonic energy and timing of the first received pulse is shown to correlate to both crimp location in the tool and the AWG of the crimp/ferrule combination. The detectability of a number of the crimp failure pathologies, such as missing strands, partially inserted wires and incomplete crimp compression, is discussed. A wave propagation model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process.
Ye, Jia; Gao, Yong
2012-01-01
Rotary instruments made of a new nickel-titanium (NiTi) alloy (M-Wire) have shown improved cyclic fatigue resistance and mechanical properties compared with those made of conventional superelastic NiTi wires. The objective of this study was to characterize microstructural changes of M-Wire throughout the cyclic fatigue process under controlled strain amplitude. The average fatigue life was calculated from 30 M-Wire samples that were subjected to a strain-controlled (≈ 4%) rotating bend fatigue test at room temperature and rotational speed of 300 rpm. Microstructural evolution of M-Wire has been investigated by different metallurgical characterization techniques, including differential scanning calorimetry, Vickers microhardness, and transmission electron microscopy at 4 different stages (as-received state, 30%, 60%, and 90% of average fatigue life). During rotating bend fatigue test, no statistically significant difference (P > .05) was found on austenite finish temperatures between as-received M-Wire and fatigued samples. However, significant differences (P < .05) were observed on Vickers microhardness for samples with 60% and 90% fatigue life compared with as-received and 30% fatigue life. Coincidentally, substantial growth of martensite grains and martensite twins was observed in microstructure under transmission electron microscopy after 60% fatigue life. The results of the present study suggested that endodontic instruments manufactured with M-Wire are expected to have higher strength and wear resistance than similar instruments made of conventional superelastic NiTi wires because of its unique nano-crystalline martensitic microstructure. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
2. Historic American Buildings Survey, Arthur W. Stewart, Photographer November ...
2. Historic American Buildings Survey, Arthur W. Stewart, Photographer November 27, 1936 SOUTH ELEVATION (FRONT). - Judge Sebron G. Sneed House, Route I-35 & Bluff Springs Road, Austin, Travis County, TX
A Test of the Cultural Dependency Theory in Seven Latin American Newspapers.
ERIC Educational Resources Information Center
Link, Jere H.
Cultural dependency has become a serious international issue over the past two decades, especially as it relates to the news media. If charges that the Latin American media are subservient to foreign interests have any truth, then the content of their media should closely resemble that of the foreign wires to which they subscribe. The news can be…
Modal parameters of space structures in 1 G and 0 G
NASA Technical Reports Server (NTRS)
Bicos, Andrew S.; Crawley, Edward F.; Barlow, Mark S.; Van Schoor, Marthinus C.; Masters, Brett
1993-01-01
Analytic and experimental results are presented from a study of the changes in the modal parameters of space structural test articles from one- to zero-gravity. Deployable, erectable, and rotary modules was assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. The structures were modeled as if hanging from a suspension system in one gravity, and unconstrained, as if free floating in zero-gravity. The analysis is compared with ground experimental measurements, which were made on a spring-wire suspension system with a nominal plunge frequency of one Hertz, and with measurements made on the Shuttle middeck. The degree of change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, reassembly, shipset, suspension, and ambient gravity level.
Middeck zero-gravity dynamics experiment - Comparison of ground and flight test data
NASA Technical Reports Server (NTRS)
Crawley, Edward F.; Barlow, Mark S.; Van Schoor, Marthinus C.; Masters, Brett; Bicos, Andrew S.
1992-01-01
An analytic and experimental study of the changes in the modal parameters of space structural test articles from one- to zero-gravity is presented. Deployable, erectable, and rotary modules was assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. The structures were modeled as if hanging from a suspension system in one gravity, and unconstrained, as if free floating in zero-gravity. The analysis is compared with ground experimental measurements, made on a spring/wire suspension system with a nominal plunge frequency of one Hertz, and with measurements made on the Shuttle middeck. The degree of change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, and ambient gravity level.
An Approach with Hybrid Segmental Mechanics.
Mishra, Harsh Ashok; Maurya, Raj Kumar
2016-06-01
Present case report provides an insight into the hybrid segmental mechanics with treatment of 13-year-old male, considering the side effects of sole continuous arch wire sliding mechanics. Patient was diagnosed as a case of skeletal class I jaw relationship, low mandibular plane angle, class II molar relation on right and class I molar relation on left side, anterior cross bite, crowding of 12mm in upper, 5mm in lower arch. He also had proclined upper and lower anteriors by 2mm, convex profile and incompetent lips. Total treatment duration was 20 months, during which segmental canine retraction was performed with TMA (Titanium, Molybdenum, Aluminum) 'T' loop retraction spring followed by consolidation of spaces with continuous arch mechanics. Most of the treatment objectives were met with good intraoral and facial results within reasonable framework of time. This approach used traditional twin brackets, which offered the versatility to use continuous arch-wire mechanics, segmental mechanics and hybrid sectional mechanics.
Murata, Koichi; Kirkham, Christopher; Shimomura, Masaru; Nitta, Kiyofumi; Uruga, Tomoya; Terada, Yasuko; Nittoh, Koh-Ichi; Bowler, David R; Miki, Kazushi
2017-04-20
We successfully characterized the local structures of Bi atoms in a wire-δ-doped layer (1/8 ML) in a Si crystal, using wavelength dispersive fluorescence x-ray absorption fine structure at the beamline BL37XU, in SPring-8, with the help of density functional theory calculations. It was found that the burial of Bi nanolines on the Si(0 0 1) surface, via growth of Si capping layer at 400 °C by molecular beam epitaxy, reduced the Bi-Si bond length from [Formula: see text] to [Formula: see text] Å. We infer that following epitaxial growth the Bi-Bi dimers of the nanoline are broken, and the Bi atoms are located at substitutional sites within the Si crystal, leading to the shorter Bi-Si bond lengths.
The Development of Wheels for the Lunar Roving Vehicle
NASA Technical Reports Server (NTRS)
Asnani, Vivake; Delap, Damon; Creager, Colin
2009-01-01
The Lunar Roving Vehicle (LRV) was developed for NASA s Apollo program so astronauts could cover a greater range on the lunar surface, carry more science instruments, and return more soil and rock samples than by foot. Because of the unique lunar environment, the creation of flexible wheels was the most challenging and time consuming aspect of the LRV development. Wheels developed for previous lunar systems were not sufficient for use with this manned vehicle; therefore, several new designs were created and tested. Based on criteria set by NASA, the choices were narrowed down to two: the wire mesh wheel developed by General Motors (GM), and the hoop spring wheel developed by the Bendix Corporation. Each of these underwent intensive mechanical, material, and terramechanical analyses, and in the end, the wire mesh wheel was chosen for the LRV. Though the wire mesh wheel was determined to be the best choice for its particular application, it may be insufficient towards achieving the objectives of future lunar missions that could require higher tractive capability, increased weight capacity, or extended life. Therefore lessons learned from the original LRV wheel development and suggestions for future Moon wheel projects are offered.
Haghighi, Kayvon; Manolakakis, Manolis G; Balog, Connor
2017-06-01
The aim of this study was to determine the feasibility of direct transcortical stabilization of fracture dislocations of the mandibular condyle (FDMCs) using narrow-diameter non-threaded Kirschner wire (K-wire). This retrospective review reports on the treatment outcomes for 12 patients (15 fractures) with FDMCs treated with open reduction using transcortical 0.027-inch K-wire stabilization. Postoperative parameters of relevance included infection, facial nerve function, hardware removal, mandibular range of motion, and radiographic determination of fracture union. Three patients had bilateral FDMCs and 9 had unilateral FDMCs (age range at time of injury, 14 to 72 yr; mean age, 32 yr). Postoperative follow-up ranged from 6 weeks to 2 years. Four patients required removal of K-wire hardware for different reasons. K-wires were removed because of infection in 1 patient. Another patient required removal because of migration of the pin into the joint space. One pin was removed electively and another was removed for nonspecific postoperative symptoms that resolved after pin removal. Persistent facial nerve deficit was observed in 1 patient. Open reduction with transcortical K-wire stabilization can achieve satisfactory outcomes for the treatment of FDMC. Further investigation is needed in determining the efficacy of this fixation technique in the management of FDMC. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Outlook for blight-resistant American chestnut trees
Paul H. Sisco
2009-01-01
Culminating 20 years of breeding efforts, in spring 2008, The American Chestnut Foundation (TACF) delivered its first 500 chestnuts to the USDA Forest Service for testing on National Forest lands. The expectation is that these seedlings will be more resistant to chestnut blight (Cryphonectria parasitica) than are pure American chestnut trees (
Spring loaded thermocouple module
McKelvey, T.E.; Guarnieri, J.J.
1984-03-13
A thermocouple arrangement is provided for mounting in a blind hole of a specimen. The thermocouple arrangement includes a cup-like holder member, which receives an elongated thermal insulator, one end of which is seated at an end wall of the holder. A pair of thermocouple wires, threaded through passageways in the insulator, extend beyond the insulator member, terminating in free ends which are joined together in a spherical weld bead. A spring, held captive within the holder, applies a bias force to the weld bead, through the insulator member. The outside surface of the holder is threaded for engagement with the blind hole of the specimen. When the thermocouple is installed in the specimen, the spherical contact surface of the weld bead is held in contact with the end wall of the blind hole, with a predetermined bias force.
Spring loaded thermocouple module
McKelvey, Thomas E.; Guarnieri, Joseph J.
1985-01-01
A thermocouple arrangement is provided for mounting in a blind hole of a specimen. The thermocouple arrangement includes a cup-like holder member, which receives an elongated thermal insulator, one end of which is seated at an end wall of the holder. A pair of thermocouple wires, threaded through passageways in the insulator, extend beyond the insulator member, terminating in free ends which are joined together in a spherical weld bead. A spring, held captive within the holder, applies a bias force to the weld bead, through the insulator member. The outside surface of the holder is threaded for engagement with the blind hole of the specimen. When the thermocouple is installed in the specimen, the spherical contact surface of the weld bead is held in contact with the end wall of the blind hole, with a predetermined bias force.
An Experimental Study of the Dynamics of an Unsteady Turbulent Boundary Layer.
1982-12-01
honeycomb combination into the screen box. The screen box is made of plexiglas, and the screens are made of stainless steel wire (24 gauge, 70% porosity...port plug was modified to accommodate at its cen- ter a stainless steel stem with a disk on the end toward the inside of the tunnel. The stem is spring...necessay and Identify by block nomber) * turbulent boundary layers fluid dynamics free stream velocity A B r R CT si royy.rs ebb it ,imseesa nd ideiiit
Wire-Strain-Gage Hinge-Moment Indicators for Use in Tests of Airplane Models
NASA Technical Reports Server (NTRS)
Edwards, Howard B.
1944-01-01
The design and construction of various forms of strain-gage spring units and hinge-moment assemblies are discussed with particular reference to wind-tunnel test, although the indicators may be used equally well in flight tests. Strain-gage specifications are given, and the techniques of their application and use are described briefly. Testing, calibration and operation of hinge-moment indicators are discussed and precautions necessary for successful operation are stressed. Difficulties that may be encountered are summarized along with the possible causes.
Test probe for surface mounted leadless chip carrier
Meyer, Kerry L.; Topolewski, John
1989-05-23
A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.
Test probe for surface mounted leadless chip carrier
Meyer, K.L.; Topolewski, J.
1987-10-02
A test probe for a surface mounted leadless chip carrier is disclosed. The probe includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe. 1 fig.
NASA Astrophysics Data System (ADS)
The 1988 AGU Spring Meeting attracted more journalists than ever before. Representatives from 12 magazines, 5 newspapers, 2 wire services, and a TV station used the press room and attended the 6 news conferences. The journalists were attracted to the meeting, held May 16-in Baltimore, Md., by 6 press releases mailed out by the AGU public information staff in the 2 months before the meeting. Correspondents from as far as Sweden and Japan joined U.S. reporters from San Francisco, New York, Washington, D.C. and Baltimore.
11. Historic American Buildings Survey Cortlandt Van Dyke Hubbard, Photographer ...
11. Historic American Buildings Survey Cortlandt Van Dyke Hubbard, Photographer October 1959 INTERIOR DETAIL OF FRAME CONSTRUCTION - White Meadow Farm, State Roads 290 & 262 (moved to Lewes, DE), Cool Spring, Sussex County, DE
4. Historic American Buildings Survey, Arthur W. Stewart, Photographer November ...
4. Historic American Buildings Survey, Arthur W. Stewart, Photographer November 27, 1936 SOUTHWEST ELEVATION OF SECOND FLOOR FIREPLACE. - Judge Sebron G. Sneed House, Route I-35 & Bluff Springs Road, Austin, Travis County, TX
Design of a Telescopic Linear Actuator Based on Hollow Shape Memory Springs
NASA Astrophysics Data System (ADS)
Spaggiari, Andrea; Spinella, Igor; Dragoni, Eugenio
2011-07-01
Shape memory alloys (SMAs) are smart materials exploited in many applications to build actuators with high power to mass ratio. Typical SMA drawbacks are: wires show poor stroke and excessive length, helical springs have limited mechanical bandwidth and high power consumption. This study is focused on the design of a large-scale linear SMA actuator conceived to maximize the stroke while limiting the overall size and the electric consumption. This result is achieved by adopting for the actuator a telescopic multi-stage architecture and using SMA helical springs with hollow cross section to power the stages. The hollow geometry leads to reduced axial size and mass of the actuator and to enhanced working frequency while the telescopic design confers to the actuator an indexable motion, with a number of different displacements being achieved through simple on-off control strategies. An analytical thermo-electro-mechanical model is developed to optimize the device. Output stroke and force are maximized while total size and power consumption are simultaneously minimized. Finally, the optimized actuator, showing good performance from all these points of view, is designed in detail.
Development of the RANCOR Rotary-Percussive Coring System for Mars Sample Return
NASA Technical Reports Server (NTRS)
Paulsen, Gale; Indyk, Stephen; Zacny, Kris
2014-01-01
A RANCOR drill was designed to fit a Mars Exploration Rover (MER) class vehicle. The low mass of 3 kg was achieved by using the same actuator for three functions: rotation, percussions, and core break-off. Initial testing of the drill exposed an unexpected behavior of an off-the-shelf sprag clutch used to couple and decouple rotary-percussive function from the core break off function. Failure of the sprag was due to the vibration induced during percussive drilling. The sprag clutch would back drive in conditions where it was expected to hold position. Although this did not affect the performance of the drill, it nevertheless reduced the quality of the cores produced. Ultimately, the sprag clutch was replaced with a custom ratchet system that allowed for some angular displacement without advancing in either direction. Replacing the sprag with the ratchet improved the collected core quality. Also, premature failure of a 300-series stainless steel percussion spring was observed. The 300-series percussion spring was ultimately replaced with a music wire spring based on performances of previously designed rotary-percussive drill systems.
Size dependent nanomechanics of coil spring shaped polymer nanowires
NASA Astrophysics Data System (ADS)
Ushiba, Shota; Masui, Kyoko; Taguchi, Natsuo; Hamano, Tomoki; Kawata, Satoshi; Shoji, Satoru
2015-11-01
Direct laser writing (DLW) via two-photon polymerization (TPP) has been established as a powerful technique for fabrication and integration of nanoscale components, as it enables the production of three dimensional (3D) micro/nano objects. This technique has indeed led to numerous applications, including micro- and nanoelectromechanical systems (MEMS/NEMS), metamaterials, mechanical metamaterials, and photonic crystals. However, as the feature sizes decrease, an urgent demand has emerged to uncover the mechanics of nanosized polymer materials. Here, we fabricate coil spring shaped polymer nanowires using DLW via two-photon polymerization. We find that even the nanocoil springs follow a linear-response against applied forces, following Hooke’s law, as revealed by compression tests using an atomic force microscope. Further, the elasticity of the polymer material is found to become significantly greater as the wire radius is decreased from 550 to 350 nm. Polarized Raman spectroscopy measurements show that polymer chains are aligned in nanowires along the axis, which may be responsible for the size dependence. Our findings provide insight into the nanomechanics of polymer materials fabricated by DLW, which leads to further applications based on nanosized polymer materials.
Size dependent nanomechanics of coil spring shaped polymer nanowires.
Ushiba, Shota; Masui, Kyoko; Taguchi, Natsuo; Hamano, Tomoki; Kawata, Satoshi; Shoji, Satoru
2015-11-27
Direct laser writing (DLW) via two-photon polymerization (TPP) has been established as a powerful technique for fabrication and integration of nanoscale components, as it enables the production of three dimensional (3D) micro/nano objects. This technique has indeed led to numerous applications, including micro- and nanoelectromechanical systems (MEMS/NEMS), metamaterials, mechanical metamaterials, and photonic crystals. However, as the feature sizes decrease, an urgent demand has emerged to uncover the mechanics of nanosized polymer materials. Here, we fabricate coil spring shaped polymer nanowires using DLW via two-photon polymerization. We find that even the nanocoil springs follow a linear-response against applied forces, following Hooke's law, as revealed by compression tests using an atomic force microscope. Further, the elasticity of the polymer material is found to become significantly greater as the wire radius is decreased from 550 to 350 nm. Polarized Raman spectroscopy measurements show that polymer chains are aligned in nanowires along the axis, which may be responsible for the size dependence. Our findings provide insight into the nanomechanics of polymer materials fabricated by DLW, which leads to further applications based on nanosized polymer materials.
a Thermal Conduction Switch Based on Low Hysteresis Nitife Shape Memory Alloy Helical Springs
NASA Astrophysics Data System (ADS)
Krishnan, V. B.; Bewerse, C.; Notardonato, W. U.; Vaidyanathan, R.
2008-03-01
Shape memory alloy (SMA) actuators possess an inherent property of sensing a change in temperature and delivering significant force against external loads through a shape change resulting from a temperature-induced phase transformation. The utilization of a reversible trigonal (R-phase) to cubic phase transformation in NiTiFe SMAs allows for this strain recovery to occur with reduced hysteresis between the forward and reverse transformations. However, the magnitude of the strain recovery associated with the R-phase transformation is lower than that of the monoclinic to cubic phase transformation. The use of helical springs can compensate for this design constraint as they produce significant stroke when compared to straight elements such as thin strips and wires. This work reports on the development and implementation of NiTiFe helical springs in a low-hysteresis thermal conduction switch for advanced spaceport applications associated with NASA's requirements for future lunar and Mars missions. Such a low-hysteresis thermal conduction switch can provide on-demand heat transfer between two reservoirs at different temperatures.
Development of a prototype flexible radiator system
NASA Technical Reports Server (NTRS)
Hixon, C. W.
1979-01-01
The radiator is a roll-up flexible panel with the transport fluid manifolds located at the ends of the 27 foot length. A total of fifty Teflon flow tubes are sandwiched between the layers of silver wire mesh and sealed in the Teflon film. The transport fluid flows from an inlet manifold through 25 panel flow tubes to the end of the radiator panel into a manifold which directs the fluid into the other 25 flow tubes on its return to the base of the radiator. Deployment/retraction of the flexible radiator panel is by low pressure inflation tubes (one along each side of the panel) which incorporate a flat spring. The spring supplies the retraction force to wind the radiator panel on a drum when the pressure in the inflation tubes is relieved. Room ambient deployment tests of the radiator panel were conducted to verify the inflation tube spring deployment, and retraction capability. The panel underwent a thermal vacuum, solar spectrum exposure test. After approximately 100 hours of solar exposure, post-test inspection revealed no structural or optical properties degraded.
Comparisons of nanoindentation, 3-point bending, and tension tests for orthodontic wires.
Iijima, Masahiro; Muguruma, Takeshi; Brantley, William A; Mizoguchi, Itaru
2011-07-01
The purposes of this study were to obtain information about mechanical properties with the nanoindentation test for representative wire alloys and compare the results with conventional mechanical tests. Archwires having 0.016 × 0.022-in cross sections were obtained of 1 stainless steel, 1 cobalt-chromium-nickel, 1 beta-titanium alloy, and 2 nickel-titanium products. Specimens of as-received wires were subjected to nanoindentation testing along the external surfaces and over polished cross sections to obtain values of hardness and elastic modulus. Other specimens of as-received wires were subjected to Vickers hardness, 3-point bending, and tension tests. All testing was performed at 25°C. Differences were found in hardness and elastic modulus obtained with the nanoindentation test at the external and cross-sectioned surfaces and with the conventional mechanical-property tests. Mechanical properties obtained with the nanoindentation test generally varied with indentation depth. The 3 testing methods did not yield identical values of hardness and elastic modulus, although the order among the 5 wire products was the same. Variations in results for the nanoindentation and conventional mechanical property tests can be attributed to the different material volumes sampled, different work-hardening levels, and an oxide layer on the wire surface. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
McLaughlin, Richard P; Bennett, John C
2015-06-01
Until the early 1970s, successful treatment with the Begg technique and the Tweed edgewise technique required tedious wire bending. The introduction of Andrews' straight wire appliance changed that, and it was one of the most significant contributions in the history of orthodontics. The straight wire appliance significantly reduced the amount of wire bending and also brought along other options in treatment mechanics. Retraction of the canines with elastic chains and ligature wires became more common. Sliding mechanics in place of closing loops became the method of space closure for a significant number of clinicians. Edgewise force levels were initially used to close spaces; however, it was soon observed that lighter forces were more effective with sliding mechanics. Along with these changes, it became apparent that compensation in the appliance was needed, depending on the type of malocclusion and particularly with varying extraction sequences. Various appliance designs were developed to accommodate changes in mechanics and force levels. These modifications improved tooth positions at the end of treatment as long as the brackets were properly placed. These major changes in appliances, force levels, and treatment mechanics can be traced back to the work of Dr Lawrence Andrews and the straight wire appliances. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Things That Go "Peent" in the Night.
ERIC Educational Resources Information Center
Neidich, Carole Louise
1981-01-01
Describes early spring night field trips by two naturalists and ten adults, armed with cameras and flashlights, in search of Spotted Salamanders performing ritual mating dances. Although dancing salamanders proved elusive, their habits and those of other pond life were examined and Spring American Woodcock nuptial flights were observed. (NEC)
12 CFR 790.2 - Central and field office organization.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., Wisconsin 4807 Spicewood Springs Road, Suite 5200, Austin, TX 78759-8490. V Alaska, Arizona, American Samoa... management of conservatorships. The address of AMAC is 4807 Spicewood Springs Road, Suite 5100, Austin, Texas... developing and conducting research in support of NCUA programs, and for preparing reports on research...
ERIC Educational Resources Information Center
Library Journal, 2011
2011-01-01
While they do not represent the rainbow of reading tastes American public libraries accommodate, Book Review editors are a wildly eclectic bunch. One look at their bedside tables and ereaders would reveal very little crossover. This article highlights an eclectic array of spring offerings ranging from print books to an audiobook to ebook apps. It…
4. Historic American Buildings Survey, W. Jeter EasonDeputy District Officer, ...
4. Historic American Buildings Survey, W. Jeter Eason-Deputy District Officer, Photographer August 3, 1936 OPEN 'DOG-TROT' PORCH (LOOKING SOUTH). - Wynnewood, Gallatin-Hartsville Pike (State Highway 25), Castalian Springs, Sumner County, TN
1. Historic American Buildings Survey, Arthur W. Stewart, Photographer November ...
1. Historic American Buildings Survey, Arthur W. Stewart, Photographer November 27, 1936 SOUTHWEST ELEVATION (SOUTH FRONT AND WEST SIDE). - Judge Sebron G. Sneed House, Route I-35 & Bluff Springs Road, Austin, Travis County, TX
Tight Placement of Erich Arch Bar While Avoiding Wire Fatigue Failure.
Kirk, Daniel; Whitney, Joseph; Shafer, David; Song, Liansheng
2016-03-01
To determine the number of wire twists needed to acquire ideal Erich arch bar tightness before wire fatigue failure (fracture) in relation to different distances and angles at which different gauge wires are grasped to provide information to improve the efficiency of arch bar application. This study mimicked surgical placement of arch bars with 24- and 26-gauge wires. The number of twists to tightness and failure was evaluated when the wire distance between the arch bar and wire holder tip changed (5 vs 10 mm) and when the degree at which the wire was held relative to the tooth axis was changed (45° vs 90°). A wire shearing test also was used to investigate the fatigability of wires tightened under these same conditions. Wires twisted to tightness, past tightness, and after shearing test movements were visualized with electron microscopy. For 24-gauge wire held at 5 mm, 2.6 to 2.8 twists were needed for wire tightness, with failure after 1.7 to 1.9 twists past tightness; for 24-gauge wire held at 10 mm, 4.4 to 4.9 twists produced tightness, with failure after 2.3 to 2.9 twists past tightness. For 26-gauge wire held at 5 mm, 3.3 to 3.5 twists provided tightness, with 1.6 to 1.8 twists past tightness causing failure; for 26-gauge wire held at 10 mm, 5.1 to 5.5 twists produced tightness, with 3.1 to 3.7 twists past tightness causing failure. At a 45° angle, the wire tightened with fewer twists and showed more resistance to failure with twists past tightness compared with 90° using 24- and 26-gauge wires. In contrast, 24-gauge wire held at a 5-mm distance showed the opposite result, with decreased resistance to failure at the 45° angle. However, the differences were not statistically meaningful. Scanning election microscopy showed no wire fatigue for either angle for 26-gauge wire held at a 5-mm distance and twisted to tightness. After overtightening and oscillation, the 90° angle trials showed fatigue, whereas the 45° angle trials did not. Holding a 24-gauge wire at 45° to the tooth axis is recommended owing to fewer twists to tightness and more resistance to failure. A 5-mm grasping distance is recommended for experienced surgeons owing to fewer twists to tightness, whereas a 10-mm grasping distance is recommended for novice surgeons owing to a greater tolerance for over-twisting before failure. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Park, Chul-Hyun; Ahn, Ji-Yong; Kim, Yu-Mi; Lee, Woo-Chun
2013-06-01
The purpose of this study was to compare the results of hallux valgus surgery between feet fixed with Kirschner wires and those fixed with a plate and screws. Between December 2008 and November 2009, 53 patients (62 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. Thirty-four patients (41 feet) were stabilised with Kirschner wires (K-wire group) and 19 patients (21 feet) were stabilised with a locking plate (plate group). Clinical results were assessed using American Orthopaedic Foot and Ankle Society (AOFAS) score. Radiographic parameters were compared between these groups. Recurrence rate at the last follow-up was compared between the K-wire and plate groups. Mean AOFAS score was lower in the plate group, however, the difference between the groups was not statistically significant in AOFAS score at the last follow-up. Hallux valgus angle and intermetatarsal angle were significantly larger in the plate group at the last follow-up. Mean 1-2 metatarsal (MT) distance on immediately postoperative radiographs was significant larger in the plate group. Four (9.8 %) of the 41 feet in the K-wire group and 7 (33.3 %) of the 21 feet in the plate group showed hallux valgus recurrence at the last follow-up. The plate group had a significantly higher risk of recurrence than the K-wire group. Fixation of proximal chevron osteotomy using a plate and screws has a greater risk of hallux valgus recurrence than fixation using Kirschner wires.
Miga Aero Actuator and 2D Machined Mechanical Binary Latch
NASA Technical Reports Server (NTRS)
Gummin, Mark A.
2013-01-01
Shape memory alloy (SMA) actuators provide the highest force-to-weight ratio of any known actuator. They can be designed for a wide variety of form factors from flat, thin packages, to form-matching packages for existing actuators. SMA actuators can be operated many thousands of times, so that ground testing is possible. Actuation speed can be accurately controlled from milliseconds to position and hold, and even electronic velocity-profile control is possible. SMA actuators provide a high degree of operational flexibility, and are truly smart actuators capable of being accurately controlled by onboard microprocessors across a wide range of voltages. The Miga Aero actuator is a SMA actuator designed specifically for spaceflight applications. Providing 13 mm of stroke with either 20- or 40-N output force in two different models, the Aero actuator is made from low-outgassing PEEK (polyether ether ketone) plastic, stainless steel, and nickel-titanium SMA wires. The modular actuator weighs less than 28 grams. The dorsal output attachment allows the Aero to be used in either PUSH or PULL modes by inverting the mounting orientation. The SPA1 actuator utilizes commercially available SMA actuator wire to provide 3/8-in. (approx. =.1 cm) of stroke at a force of over 28 lb (approx. = .125 N). The force is provided by a unique packaging of the single SMA wire that provides the output force of four SMA wires mechanically in parallel. The output load is shared by allowing the SMA wire to slip around the output attachment end to adjust or balance the load, preventing any individual wire segment from experiencing high loads during actuation. A built-in end limit switch prevents overheating of the SMA element following actuation when used in conjunction with the Miga Analog Driver [a simple MOSFET (metal oxide semiconductor field-effect transistor) switching circuit]. A simple 2D machined mechanical binary latch has been developed to complement the capabilities of SMA wire actuators. SMA actuators typically perform ideally as latch-release devices, wherein a spring-loaded device is released when the SMA actuator actuates in one direction. But many applications require cycling between two latched states open and closed.
1. Historic American Buildings Survey, William F. Winter, Jr., Photographer ...
1. Historic American Buildings Survey, William F. Winter, Jr., Photographer Spring 1931, GENERAL VIEW - SHOPS, Gift of New York State Department of Education. - Shaker Upper Canaan Family, Shop Buildings, Shaker Road, New Lebanon, Columbia County, NY
8. Historic American Buildings Survey Cortlandt Van Dyke Hubbard, Photographer ...
8. Historic American Buildings Survey Cortlandt Van Dyke Hubbard, Photographer October 1959 BRICK NOGGING AND ORIGINAL WEATHERBOARDING OF SOUTH ELEVATION - White Meadow Farm, State Roads 290 & 262 (moved to Lewes, DE), Cool Spring, Sussex County, DE
1. Historic American Buildings Survey E. W. Russell, Photographer, September ...
1. Historic American Buildings Survey E. W. Russell, Photographer, September 15, 1936 GATE IN FRONT OF 201 GOVERNMENT STREET - 201 Government Street (Iron Gate), Moved to Spring Hill Avenue & Riviere du Chin Road, Mobile, Mobile County, AL
1. Historic American Buildings Survey, Cervin Robinson, Photographer August, 1958 ...
1. Historic American Buildings Survey, Cervin Robinson, Photographer August, 1958 EAST ELEVATION SHOWING SPRING HOUSE ON THE LEFT AND SMALL KAUFMAN HOUSE ON THE RIGHT. - Kaufman House, State Route 662 vicinity (Oley Township), Oley, Berks County, PA
Welsh, Stuart A.; Aldinger, Joni L.; Braham, Melissa A.; Zimmerman, Jennifer L.
2016-01-01
Monitoring of dam passage can be useful for management and conservation assessments of American eel, particularly if passage counts can be examined over multiple years. During a 7-year study (2007–2013) of upstream migration of American eels within the lower Shenandoah River (Potomac River drainage), we counted and measured American eels at the Millville Dam eel pass, where annual study periods were determined by the timing of the eel pass installation during spring or summer and removal during fall. Daily American eel counts were analysed with negative binomial regression models, with and without a year (YR) effect, and with the following time-varying environmental covariates: river discharge of the Shenandoah River at Millville (RDM) and of the Potomac River at Point of Rocks, lunar illumination (LI), water temperature, and cloud cover. A total of 17 161 yellow-phase American eels used the pass during the seven annual periods, and length measurements were obtained from 9213 individuals (mean = 294 mm TL, s.e. = 0.49, range 183–594 mm). Data on passage counts of American eels supported an additive-effects model (YR + LI + RDM) where parameter estimates were positive for river discharge (β = 7.3, s.e. = 0.01) and negative for LI (β = −1.9, s.e. = 0.34). Interestingly, RDM and LI acted synergistically and singularly as correlates of upstream migration of American eels, but the highest daily counts and multiple-day passage events were associated with increased RDM. Annual installation of the eel pass during late spring or summer prevented an early spring assessment, a period with higher RDM relative to those values obtained during sampling periods. Because increases in river discharge are climatically controlled events, upstream migration events of American eels within the Potomac River drainage are likely linked to the influence of climate variability on flow regime.
Astronauts Jerry Ross and Sherwood Spring survey assembled ACCESS components
1985-12-01
Astronauts Jerry L. Ross (right) and Sherwood C. (Woody) Spring (left) share a foot restraint as they survey the assembled ACCESS components after a lengthy extravehicular activity. Both men salute the American flag placed on the assembled ACCESS tower. Stowed EASE pieces are reflected in the window through which the photo was taken.
Anarchism & Educational Policy Studies; A Marxist View of Joel Spring's "The Sorting Machine."
ERIC Educational Resources Information Center
Berlowitz, Marvin J.
A critical analysis and interpretation of "The Sorting Machine" by Joel H. Spring is presented. The book, which uses a historical revisionist approach to trace the development and impact of the corporate-government-foundation network on the ideological orientation of the American educational system, makes its greatest contribution by…
2011-05-19
Throughout that spring , he Goldsboro, on the Wilmington and Weldon Railroad, the main north-south transportation artery between Virginia and points south... spring of 1862, but Davis did not replace Lee after he took command of the Army of Northern Virginia. Braxton Bragg served as military advisor to...and publications. When called upon in the spring of 1861, Hill brought his cadets to Raleigh to start training recruits for the First North Carolina
Electromagnetic energy harvesting from a dual-mass pendulum oscillator
NASA Astrophysics Data System (ADS)
Wang, Hongyan; Tang, Jiong
2016-04-01
This paper presents the analysis of a type of vibration energy harvester composed of an electromagnetic pendulum oscillator combined to an elastic main structure. In this study, the elastic main structure connected to the base is considered as a single degree-of-freedom (DOF) spring-mass-damper subsystem. The electromagnetic pendulum oscillator is considered as a dual-mass two-frequency subsystem, which is composed of a hollow bar with a tip winded coil and a magnetic mass with a spring located in the hollow bar. As the pendulum swings, the magnetic mass can move along the axial direction of the bar. Thus, the relative motion between the magnet and the coil induces a wire current. A mathematical model of the coupled system is established. The system dynamics a 1:2:1 internal resonance. Parametric analysis is carried out to demonstrate the effect of the excitation acceleration, excitation frequency, load resistance, and frequency tuning parameters on system performance.
Flexible and stretchable power sources for wearable electronics
Zamarayeva, Alla M.; Ostfeld, Aminy E.; Wang, Michael; Duey, Jerica K.; Deckman, Igal; Lechêne, Balthazar P.; Davies, Greg; Steingart, Daniel A.; Arias, Ana Claudia
2017-01-01
Flexible and stretchable power sources represent a key technology for the realization of wearable electronics. Developing flexible and stretchable batteries with mechanical endurance that is on par with commercial standards and offer compliance while retaining safety remains a significant challenge. We present a unique approach that demonstrates mechanically robust, intrinsically safe silver-zinc batteries. This approach uses current collectors with enhanced mechanical design, such as helical springs and serpentines, as a structural support and backbone for all battery components. We show wire-shaped batteries based on helical band springs that are resilient to fatigue and retain electrochemical performance over 17,000 flexure cycles at a 0.5-cm bending radius. Serpentine-shaped batteries can be stretched with tunable degree and directionality while maintaining their specific capacity. Finally, the batteries are integrated, as a wearable device, with a photovoltaic module that enables recharging of the batteries. PMID:28630897
NASA Technical Reports Server (NTRS)
Stevens, N. J.; Levell, R. R.; Klinect, V. W.
1976-01-01
The transient event counter (TEC), senses and counts transients having a voltage rise of greater than five volts in three separate wire harnesses: the attitude control harness, the solar array instrumentation harness and the solar array power harness. The operational characteristics of TEC are defined and the preliminary results obtained through the first 90 days of operation including the spring 1976 eclipse season are presented. The results show that the Communications Technology Satellite was charged to the point where discharges occurred. The discharge induced transients did not cause any anomalous events in spacecraft operation. The data indicate that discharges can occur at any time during the day without preference to any local time quadrant. The number of discharges occurring in the one second sample interval are greater than anticipated. The compilation and review of the data is continuing.
Hupp, Jerry W.; Yamaguchi, Noriyuki; Flint, Paul L.; Pearce, John M.; Tokita, Ken-ichi; Shimada, Tetsuo; Ramey, Andrew M.; Kharitonov, Sergei; Higuchi, Hiroyoshi
2011-01-01
In North America, spring migration routes and breeding distribution of northern pintails Anas acuta vary because some individuals opportunistically nest at mid-latitudes in years when ephemeral prairie wetlands are available, whereas others regularly nest in arctic and sub-arctic regions where wetland abundance is more constant. Less was known about migration routes and breeding distribution of pintails in East Asia. From 2007–2009 we marked 198 pintails on their wintering areas in Japan with satellite transmitters to: 1) document spring migration routes and summer distribution, 2) evaluate migratory connections and breeding season sympatry with North American pintails, and 3) determine if pintails used the same migration routes in fall as in spring. Most pintails (67%) migrated to the Kamchatka or Chukotka peninsulas in eastern Russia either directly from Japan or via Sakhalin Island, Russia. Remaining pintails primarily migrated to the Magadan region or Kolyma River Basin in eastern Russia via Sakhalin Island. The Chukotka Peninsula was the most common summer destination, with highest densities in the Anadyr Lowlands; a region also used by pintails that migrate from North America. One pintail migrated to St. Lawrence Island, Alaska, in spring and another briefly migrated to the western coast of Alaska in fall. Autumn migration routes generally mirrored spring migration although most pintails bypassed Sakhalin Island in fall. Compared to North American pintails, pintails that winter in Japan exhibited less variation in migration routes and breeding distribution, and nested at higher latitudes. In the Russian Far East there is no region with habitats comparable in extent to the ephemeral mid-latitude wetlands of North America. Consequently, East Asian pintails mainly nest in arctic and sub-arctic regions where annual consistency in wetlands promotes constancy in migration routes and breeding distribution. Breeding season sympatry between pintails from different continents results more from North American pintails migrating to eastern Russia than from Japanese pintails migrating to North America.
Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play.
Lee, Youngran; Lee, Dong-Yul; Kim, Yoon-Ji R
2016-09-01
To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). In all bracket systems, the slot tops were significantly wider than the slot bases (P < .001), yielding a divergent slot profile. Clarity-SLs (3M Unitek, Monrovia, Calif) showed the greatest divergence among the 0.022-inch brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 × 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 × 0.022-inch SS wire (Ortho Technology).
2008-01-01
Assessing and understanding the health needs and capacities of college students is paramount to creating healthy campus communities. The American College Health Association-National College Health Assessment (ACHA-NCHA) is a survey that ACHA developed in 1998 to assist institutions of higher education in achieving this goal. The ACHA-NCHA contains approximately 300 questions assessing student health status and health problems, risk and protective behaviors, and impediments to academic performance. The spring 2007 reference group includes ACHA-NCHA data from 71,860 students at 107 institutions of higher education. Officials at participating institutions administered the ACHA-NCHA to all students, to randomly selected students, or to students in randomly selected classrooms. ACHA collected data between January and May 2007. Results from the spring 2007 reference group (N= 71,860) are presented. These data expand the understanding of the health needs and capacities of college students.
ERIC Educational Resources Information Center
Journal of American College Health, 2005
2005-01-01
Assessing and understanding the health needs and capacities of college students is paramount to creating healthy campus communities. The American College Health Association-National College Health Assessment (ACHA-NCHA) is a survey instrument developed by the American College Health Association (ACHA) in 1998 to assist institutions of higher…
Supporting the Career Aspirations of American Indian Youth. CURA Reporter, Spring 2005
ERIC Educational Resources Information Center
Alliman-Brissett, Annette E; Turner, Sherri L.
2005-01-01
Dropout rates among American Indian young people are greater than 50% in some places in the country, and the rate of unemployment and underemployment among American Indians still far exceeds that of the majority population, despite affirmative action and other parity-seeking policies. In addition, U.S. Census trends indicate an influx of American…
VIEW EASTLEFTBUILDING 2 PHYSICAL TESTING HOUSE (1928) RIGHTBUILDING 7 MACHINE ...
VIEW EAST-LEFT-BUILDING 2 PHYSICAL TESTING HOUSE (1928) RIGHT-BUILDING 7 MACHINE SHOP (1901 SECTION) - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
Growth and survival of sea lampreys from metamorphosis to spawning in Lake Huron
Swink, William D.; Johnson, Nicholas S.
2014-01-01
Larval Sea Lampreys Petromyzon marinus live burrowed in stream bottoms and then metamorphose into their parasitic stage. Among larvae that metamorphose in a given year (i.e., parasitic cohort), autumn out-migrants (October–December) to the Laurentian Great Lakes can feed on fish for up to 6 months longer than spring outmigrants (March–May), which overwinter in streams without feeding. We evaluated whether the season of outmigration affected growth or survival of newlymetamorphosed Sea Lampreys in LakeHuron. Newlymetamorphosed individuals (n=2,718) from three parasitic cohorts were netted during their out-migration from BlackMallard Creek, Michigan, to LakeHuron during autumn 1997 through spring 2000; each out-migrant was injected with a sequentially numbered coded wire tag and was released back into the creek. After up to 18 months of feeding in the Great Lakes, 224 (8.2%) Sea Lampreys were recaptured (in 1999–2001) as upstream-migrating adults in tributaries to Lakes Huron and Michigan. Recovery rates of autumn and spring out-migrants as adults were 9.4% and 7.8%, respectively, and these rates did not significantly differ. Overwinter feeding (i.e., as parasites) by autumn out-migrants did not produce adult mean sizes greater than those of spring out-migrants. Because we detected no growth or survival differences between autumn and spring out-migrants, the capture of newly metamorphosed Sea Lampreys at any point during their out-migration should provide equal reductions in damage to Great Lakes fisheries. The absence of a difference in growth or survival between autumn and spring out-migrants is an aspect of Sea Lamprey life history that yields resiliency to this invasive parasite and complicates efforts for its control in the Great Lakes.
6. Historic American Buildings Survey E. W. Russell, Photographer, Feb. ...
6. Historic American Buildings Survey E. W. Russell, Photographer, Feb. 12, 1937 VIEW LOOKING UP MAIN DRIVEWAY SHOWING SO. E. (UPPER PORTION) OF BLDG. ALSO WEST ELEV. OF CHURCH. - Convent of the Visitation, 2300 Spring Hill Avenue, Mobile, Mobile County, AL
Resources for Hope: Ideas for Alternatives from Heterodox Higher Education Institutions
ERIC Educational Resources Information Center
Butcher, Catherine Norma
2017-01-01
This report describes my field visits to Berea and Deep Springs Colleges in the U.S.A. and explores their forms of ownership/control, governance, financing and organisational structure. Berea and Deep Springs are small, liberal arts colleges, distinctive in American higher education, in which students actively participate in a spirit of democracy.…
Community, Colony, and Network: Survival of Greco-American Culture in Tarpon Springs, Florida.
ERIC Educational Resources Information Center
Smith, Sheldon
This paper reviews literature on ethnicity and acculturation, presents a theoretical framework whose master variable is the nature of an ethnic group's organization, and applies the theory to the Greek colony of Tarpon Springs, Florida. It is shown that when the key features of cultural continuity (church, language schools, voluntary associations)…
Inami, Takumi; Kataoka, Masaharu; Shimura, Nobuhiko; Ishiguro, Haruhisa; Yanagisawa, Ryoji; Fukuda, Keiichi; Yoshino, Hideaki; Satoh, Toru
2014-11-01
This study sought to prove the safety and effectiveness of pressure-wire-guided percutaneous transluminal pulmonary angioplasty (PTPA). PTPA has been demonstrated to be effective for treatment of chronic thromboembolic pulmonary hypertension. However, a major and occasionally fatal complication after PTPA is reperfusion pulmonary edema. To avoid this, we developed the PEPSI (Pulmonary Edema Predictive Scoring Index). The pressure wire has been used to detect insufficiency of flow in a vessel. We included 350 consecutive PTPA sessions in 103 patients with chronic thromboembolic pulmonary hypertension from January 1, 2009 to December 31, 2013. During these 5 years, 140 PTPA sessions were performed without guidance, 65 with guidance of PEPSI alone, and 145 with both PEPSI and pressure-wire guidance. Each PTPA session was finished after achieving PEPSI scores of <35.4 with PEPSI guidance and each target lesion achieving distal mean pulmonary arterial pressure <35 mm Hg with pressure-wire guidance. The occurrence of clinically critical reperfusion pulmonary edema and vessel injuries were lowest in the group using the guidance of both pressure wire and PEPSI (0% and 6.9%, respectively). Furthermore, the group guided by pressure wire and PEPSI accomplished the same hemodynamic improvements with fewer numbers of target lesions treated and sessions performed. The combined approach using pressure wire and PEPSI produced more efficient clinical results and greatly reduced reperfusion pulmonary edema and vessel complications. This is further evidence that PTPA is an alternative strategy for treating chronic thromboembolic pulmonary hypertension. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Liu, Jia-Kuang; Lee, Tzer-Min; Liu, I-Hua
2011-08-01
For orthodontic applications, equiatomic nickel-titanium (NiTi) wires are used to level and align the teeth under bending conditions in the oral environment for long periods. The aim of study was to investigate the influence of bending stress on the nickel release of commercial NiTi orthodontic wires in vitro, simulating the intraoral environment as realistically as possible. Two types of as-received orthodontic NiTi wires, free of performed internal stress, were immersed in artificial saliva. Half of the NiTi wires were exposed to continuous bending stress throughout the 14-day experimental period. The stressed NiTi wires exhibited substantial increases in the nickel release compared with the unstressed specimens during all experimental periods. The highest dissolution rate during the 0 to 1 day incubation period was observed for all stressed specimens. However, a slight increase of nickel released as a function of time was observed in the 3 groups of stressed specimens after 3 days of immersion. For the stressed specimens, it was hypothesized that the bending stress would induce buckling or cracking of the protective oxide film of the NiTi wires. In this study, the mechanism of nickel release was the underlying metal surface reacting with the surrounding environment. The results indicated that bending stress influences the nickel release of NiTi wires. The factor of loading condition with respect to corrosion behavior and passive film should be considered in view of the widespread use of NiTi wires for dental devices. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Albright, Rachel H; Waverly, Brett J; Klein, Erin; Weil, Lowell; Weil, Lowell S; Fleischer, Adam E
Hammertoe deformities are one of the most common foot deformities, affecting up to one third of the general population. Fusion of the joint can be achieved with various devices, with the current focus on percutaneous Kirschner (K)-wire fixation or commercial intramedullary implant devices. The purpose of the present study was to determine whether surgical intervention with percutaneous K-wire fixation versus commercial intramedullary implant is more cost effective for proximal interphalangeal joint arthrodesis in hammertoe surgery. A formal cost-effectiveness analysis using a decision analytic tree model was conducted to investigate the healthcare costs and outcomes associated with either K-wire or commercial intramedullary implant fixation. The outcomes assessed included long-term costs, quality-adjusted life-years (QALYs), and incremental cost per QALY gained. Costs were evaluated from the healthcare system perspective and are expressed in U.S. dollars at a 2017 price base. Our results found that commercial implants were minimally more effective than K-wires but carried significantly higher costs. The total cost for treatment with percutaneous K-wire fixation was $5041 with an effectiveness of 0.82 QALY compared with a commercial implant cost of $6059 with an effectiveness of 0.83 QALY. The incremental cost-effectiveness ratio of commercial implants was $146,667. With an incremental cost-effectiveness ratio of >$50,000, commercial implants failed to justify their proposed benefits to outweigh their cost compared to percutaneous K-wire fixation. In conclusion, percutaneous K-wire fixation would be preferred for arthrodesis of the proximal interphalangeal joint for hammertoes from a healthcare system perspective. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Dispelling the 'bitter fog': fighting chemical defoliation in the American West.
Hay, Amy M
2012-12-01
Little doubt remains about the influence of Rachel Carson's Silent Spring in changing the consciousness of not just Americans, but citizens around the world, regarding the relationship between human beings and the natural world. Less has been done about the specific ways Carson's book inspired individual activists to continue challenging pesticide policy within the United States in the decades after the book's publication. The stories of three western women fighting the use of Agent Orange herbicides - the phenoxy herbicides 2,4-D and 2,4,5-T - illustrate the influence and mixed success of environmental activism after Silent Spring. Copyright © 2012 Elsevier Ltd. All rights reserved.
Makhlouf, Mohamed; Aboul–Ezz, Amr; Fayed, Mona Salah; Hafez, Hend
2018-01-01
BACKGROUND: The current study was carried out to compare the amount of tooth movement during canine retraction comparing two different retraction mechanics; friction mechanics represented by a NiTi closed coil spring versus frictionless mechanics represented by T - loop, and their effect on root resorption using Cone Beam Computed Tomography (CBCT). METHOD: Ten patients were selected in a split-mouth study design that had a malocclusion that necessitates the extraction of maxillary first premolars and retraction of maxillary canines. The right maxillary canines were retracted using T - loops fabricated from 0.017 X 0.025 TMA wires. The left maxillary canines received NiTi coil spring with 150 gm of retraction force. Pre retraction and post retraction Cone Beam Computed Tomography were taken to evaluate the amount of tooth movement and root resorption using three-dimensional planes. RESULTS: T - loop side showed statistically significant higher mean anteroposterior measurement than NiTi coil spring side, indicating a lower amount of canine movement pre and post a canine retraction. Concerning the root resorption, there was no statistically significant change in the mean measurements of canine root length post retraction. CONCLUSION: The NiTi coil spring side showed more distal movement more than the T-loop side. Both retraction mechanics with controlled retraction force, do not cause root resorption. PMID:29531610
Makhlouf, Mohamed; Aboul-Ezz, Amr; Fayed, Mona Salah; Hafez, Hend
2018-02-15
The current study was carried out to compare the amount of tooth movement during canine retraction comparing two different retraction mechanics; friction mechanics represented by a NiTi closed coil spring versus frictionless mechanics represented by T - loop, and their effect on root resorption using Cone Beam Computed Tomography (CBCT). Ten patients were selected in a split-mouth study design that had a malocclusion that necessitates the extraction of maxillary first premolars and retraction of maxillary canines. The right maxillary canines were retracted using T - loops fabricated from 0.017 X 0.025 TMA wires. The left maxillary canines received NiTi coil spring with 150 gm of retraction force. Pre retraction and post retraction Cone Beam Computed Tomography were taken to evaluate the amount of tooth movement and root resorption using three-dimensional planes. T - loop side showed statistically significant higher mean anteroposterior measurement than NiTi coil spring side, indicating a lower amount of canine movement pre and post a canine retraction. Concerning the root resorption, there was no statistically significant change in the mean measurements of canine root length post retraction. The NiTi coil spring side showed more distal movement more than the T-loop side. Both retraction mechanics with controlled retraction force, do not cause root resorption.
Microcoil Spring Interconnects for Ceramic Grid Array Integrated Circuits
NASA Technical Reports Server (NTRS)
Strickland, S. M.; Hester, J. D.; Gowan, A. K.; Montgomery, R. K.; Geist, D. L.; Blanche, J. F.; McGuire, G. D.; Nash, T. S.
2011-01-01
As integrated circuit miniaturization trends continue, they drive the need for smaller higher input/output (I/O) packages. Hermetically sealed ceramic area array parts are the package of choice by the space community for high reliability space flight electronic hardware. Unfortunately, the coefficient of thermal expansion mismatch between the ceramic area array package and the epoxy glass printed wiring board limits the life of the interconnecting solder joint. This work presents the results of an investigation by Marshall Space Flight Center into a method to increase the life of this second level interconnection by the use of compliant microcoil springs. The design of the spring and its attachment process are presented along with thermal cycling results of microcoil springs (MCS) compared with state-of-the-art ball and column interconnections. Vibration testing has been conducted on MCS and high lead column parts. Radio frequency simulation and measurements have been made and the MCS has been modeled and a stress analysis performed. Thermal cycling and vibration testing have shown MCS interconnects to be significantly more reliable than solder columns. Also, MCS interconnects are less prone to handling damage than solder columns. Future work that includes shock testing, incorporation into a digital signal processor board, and process evaluation of expansion from a 400 I/O device to a device with over 1,100 I/O is identified.
Force on an Asymmetric Capacitor
2003-06-01
antigravity devices, or devices that demonstrate that there is an interaction of gravity with electric phenomena.) The thin wire electrode must be at a...September 2002) American Antigravity . http://tventura.hypermart.net/index.html (accessed September 2002). 2. Stein, W. B. Electrokinetic Propulsion
76 FR 73771 - Denial of Motor Vehicle Defect Petition, DP10-002
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-29
...This notice describes the reasons for denying a petition (DP10-002) submitted to NHTSA under 49 U.S.C. Subtitle B, Chapter V, Part 552, Subpart A, requesting that the agency conduct ``an investigation of defective products manufactured by Dayton Wheel Concepts, Inc. (`Dayton Wheel' and American Wire Wheel, LLC (`American Wheel').'' The petition listed the allegedly defective products and the alleged defect (which varied by allegedly defective product).
Establishing an American Montessori Movement: Another Look at the Early Years
ERIC Educational Resources Information Center
Whitescarver, Keith; Cossentino, Jacqueline
2006-01-01
Though Montessorians have existed in the United States for nearly a century, a distinctly American version of the system did not begin to take hold until the late 1950s. What was referred to at the time as the "second spring" was actually a remarkable moment not just for Montessori education, but also for American culture at large. For…
Size dependent nanomechanics of coil spring shaped polymer nanowires
Ushiba, Shota; Masui, Kyoko; Taguchi, Natsuo; Hamano, Tomoki; Kawata, Satoshi; Shoji, Satoru
2015-01-01
Direct laser writing (DLW) via two-photon polymerization (TPP) has been established as a powerful technique for fabrication and integration of nanoscale components, as it enables the production of three dimensional (3D) micro/nano objects. This technique has indeed led to numerous applications, including micro- and nanoelectromechanical systems (MEMS/NEMS), metamaterials, mechanical metamaterials, and photonic crystals. However, as the feature sizes decrease, an urgent demand has emerged to uncover the mechanics of nanosized polymer materials. Here, we fabricate coil spring shaped polymer nanowires using DLW via two-photon polymerization. We find that even the nanocoil springs follow a linear-response against applied forces, following Hooke’s law, as revealed by compression tests using an atomic force microscope. Further, the elasticity of the polymer material is found to become significantly greater as the wire radius is decreased from 550 to 350 nm. Polarized Raman spectroscopy measurements show that polymer chains are aligned in nanowires along the axis, which may be responsible for the size dependence. Our findings provide insight into the nanomechanics of polymer materials fabricated by DLW, which leads to further applications based on nanosized polymer materials. PMID:26612544
Code of Federal Regulations, 2013 CFR
2013-04-01
... TREASURY ALCOHOL AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.98 Monterey. (a) Name... maps in the 7.5 minute series, as follows: (1) Sycamore Flat, CA, 1956, photoinspected 1972; (2) Junipero Serra Peak, CA, 1949, photoinspected 1972; (3) Reliz Canyon, CA, 1949; (4) Paraiso Springs, CA...
2. Historic American Buildings Survey E.H. Pickering, Photographer July 1936 ...
2. Historic American Buildings Survey E.H. Pickering, Photographer July 1936 SPRING HOUSE-NOW IN THE POSSESSION AND ON THE GROUNDS OF THE BALTIMORE MUSEUM OF ART. - Robert Goodloe Harper Dairy & Springhouse, (moved to Baltimore Museum of Art ..., Baltimore, Independent City, MD
Environmental Influence of Gravity and Pressure on Arc Tracking of Insulated Wires Investigated
NASA Technical Reports Server (NTRS)
2005-01-01
Momentary short-circuit arcs between a defective polyimide-insulated wire and another conductor may thermally char (pyrolize) the insulating material. The charred polyimide, being conductive, can sustain the short-circuit arc, which may propagate along the wire through continuous pyrolization of the polyimide insulation (arc tracking). If the arcing wire is part of a multiple-wire bundle, the polyimide insulation of other wires within the bundle may become thermally charred and start arc tracking also (flash over). Such arc tracking can lead to complete failure of an entire wire bundle, causing other critical spacecraft or aircraft failures. Unfortunately, all tested candidate wire insulations for aerospace vehicles were susceptible to arc tracking. Therefore, a test procedure was designed at the NASA Lewis Research Center to select the insulation type least susceptible to arc tracking. This test procedure addresses the following three areas of concern: (1) probability of initiation, (2) probability of reinitiation (restrike), and (3) extent of arc tracking damage (propagation rate). Item 2 (restrike probability) is an issue if power can be terminated from and reapplied to the arcing wire (by a switch, fuse, or resettable circuit breaker). The degree of damage from an arcing event (item 3) refers to how easily the arc chars nearby insulation and propagates along the wire pair. Ease of nearby insulation charring can be determined by measuring the rate of arc propagation. Insulation that chars easily will propagate the arc faster than insulation that does not char very easily. A popular polyimide insulated wire for aerospace vehicles, MIL-W-81381, was tested to determine a degree of damage from an arcing event (item 3) in the following three environments: (1) microgravity with air at 1-atm pressure, (2) 1g with air at 1 atm, and (3) 1g within a 10^-6 Torr vacuum. The microgravity 1-atm air was the harshest environment, with respect to the rate of damage of arc tracking, for the 20 AWG (American Wiring Gauge) MIL-W-81381 wire insulation type . The vacuum environment resulted in the least damage. Further testing is planned to determine if the environmental results are consistent between insulation types and to evaluate the other two parameters associated with arc tracking susceptibility.
Twisted ultrathin silicon nanowires: A possible torsion electromechanical nanodevice
NASA Astrophysics Data System (ADS)
Garcia, J. C.; Justo, J. F.
2014-11-01
Nanowires have been considered for a number of applications in nanometrology. In such a context, we have explored the possibility of using ultrathin twisted nanowires as torsion nanobalances to probe forces and torques at molecular level with high precision, a nanoscale system analogous to the Coulomb's torsion balance electrometer. In order to achieve this goal, we performed a first-principles investigation on the structural and electronic properties of twisted silicon nanowires, in their pristine and hydrogenated forms. The results indicated that wires with pentagonal and hexagonal cross-sections are the thinnest stable silicon nanostructures. Additionally, all wires followed a Hooke's law behavior for small twisting deformations. Hydrogenation leads to spontaneous twisting, but with angular spring constants considerably smaller than the ones for the respective pristine forms. We observed considerable changes on the nanowire electronic properties upon twisting, which allows to envision the possibility of correlating the torsional angular deformation with the nanowire electronic transport. This could ultimately allow a direct access to measurements on interatomic forces at molecular level.
Evidence for lack of homing by sea lampreys
Bergstedt, Roger A.; Seelye, James G.
1995-01-01
Recently metamorphosed sea lampreys Petromyzon marinus were captured in the Devil River, a tributary to Lake Huron, during summer and autumn 1990. They were tagged with a coded wire tag and returned to the river to continue their migration to Lake Huron to begin the parasitic (juvenile) phase of their life. During the spawning run in spring 1992 when the tagged animals were expected to mature and return to spawn, sea lampreys were trapped in nine tributaries to Lake Huron, including the Devil River; 47,946 animals were examined for coded wire tags, and 41 tagged animals were recovered. None of the 45 mature sea lampreys captured in the Devil River in 1992 were tagged, a proportion (0%) significantly lower than the proportion of the recently metamorphosed sea lampreys tagged in 1990. The distribution of tag recoveries among streams lakewide, however, was proportional to catch. Tagged sea lampreys did not appear to home, but instead seemed to select spawning streams through innate attraction to other sensory cues.
A 3D virtual reality simulator for training of minimally invasive surgery.
Mi, Shao-Hua; Hou, Zeng-Gunag; Yang, Fan; Xie, Xiao-Liang; Bian, Gui-Bin
2014-01-01
For the last decade, remarkable progress has been made in the field of cardiovascular disease treatment. However, these complex medical procedures require a combination of rich experience and technical skills. In this paper, a 3D virtual reality simulator for core skills training in minimally invasive surgery is presented. The system can generate realistic 3D vascular models segmented from patient datasets, including a beating heart, and provide a real-time computation of force and force feedback module for surgical simulation. Instruments, such as a catheter or guide wire, are represented by a multi-body mass-spring model. In addition, a realistic user interface with multiple windows and real-time 3D views are developed. Moreover, the simulator is also provided with a human-machine interaction module that gives doctors the sense of touch during the surgery training, enables them to control the motion of a virtual catheter/guide wire inside a complex vascular model. Experimental results show that the simulator is suitable for minimally invasive surgery training.
Comparison of lens- and fiber-coupled CCD detectors for X-ray computed tomography
Uesugi, K.; Hoshino, M.; Yagi, N.
2011-01-01
X-ray imaging detectors with an identical phosphor and a CCD chip but employing lens- and fiber-coupling between them have been compared. These are designed for X-ray imaging experiments, especially computed tomography, at the medium-length beamline at the SPring-8 synchrotron radiation facility. It was found that the transmittance of light to the CCD is about four times higher in the fiber-coupled detector. The uniformity of response in the lens-coupled detector has a global shading of up to 40%, while pixel-to-pixel variation owing to a chicken-wire pattern was dominant in the fiber-coupled detector. Apart from the higher transmittance, the fiber-coupled detector has a few characteristics that require attention when it is used for computed tomography, which are browning of the fiber, discontinuity in the image, image distortion, and dark spots in the chicken-wire pattern. Thus, it is most suitable for high-speed tomography of samples that tend to deform, for example biological and soft materials. PMID:21335908
Baig, M N; Baig, Usman; Tariq, Ali; Din, Robert
2017-09-20
Introduction Hallux valgus is one of the most common forefoot deformities worldwide. Females are affected more often than males. The three most common clinical symptoms are the painful bunion, transfer metatarsalgia, and hammer or claw toes. Methods This case series consisted of 20 patients who had chevron osteotomy from January 2015 to January 2016. The clinical assessment was measured by The American Orthopedic Foot and Ankle Score (AOFAS), and radiologic assessment was determined by preoperative and postoperative hallux valgus angle (HVA) and intermetatarsal angle (IMA). Results The patients' mean age was 56 years. Out of 20 patients, 19 were female, and one was male. The mean AOFAS improved from 51 preoperatively to 82 postoperatively. The HVA improved from 26° preoperatively to 14°. There were five complications including four Kirschner (K)-wire complications. Conclusion Distal chevron osteotomy is a reliable and time-tested procedure. The K-wire fixation has a relatively high complication rate. We planned to use other methods of fixation and then compared them with K-wires fixation results for future studies.
Baig, Usman; Tariq, Ali; Din, Robert
2017-01-01
Introduction Hallux valgus is one of the most common forefoot deformities worldwide. Females are affected more often than males. The three most common clinical symptoms are the painful bunion, transfer metatarsalgia, and hammer or claw toes. Methods This case series consisted of 20 patients who had chevron osteotomy from January 2015 to January 2016. The clinical assessment was measured by The American Orthopedic Foot and Ankle Score (AOFAS), and radiologic assessment was determined by preoperative and postoperative hallux valgus angle (HVA) and intermetatarsal angle (IMA). Results The patients’ mean age was 56 years. Out of 20 patients, 19 were female, and one was male. The mean AOFAS improved from 51 preoperatively to 82 postoperatively. The HVA improved from 26° preoperatively to 14°. There were five complications including four Kirschner (K)-wire complications. Conclusion Distal chevron osteotomy is a reliable and time-tested procedure. The K-wire fixation has a relatively high complication rate. We planned to use other methods of fixation and then compared them with K-wires fixation results for future studies. PMID:29167752
Izquierdo, Paula P; de Biasi, Ronaldo S; Elias, Carlos N; Nojima, Lincoln I
2010-12-01
Our purpose was to study the mechanical properties and phase transformations of orthodontic wires submitted to in-vivo exposure in the mouth for different periods of time. Stainless steel wires were tied to fixed orthodontic appliances of 30 patients from the orthodontics clinic of Universidade Federal do Rio de Janeiro School of Dentistry in Brazil. According to the duration of the clinical treatment, the patients were divided into 3 groups. After in-vivo exposure, the samples were studied by mechanical testing (torsion) and ferromagnetic resonance. Statistical analyses were carried out to evaluate the correlation between time of exposure, mechanical properties, and austenite-to-martensite transformation among the groups. The results were compared with as-received control samples. The torque values increased as time in the mouth increased. The increase in torque resistance showed high correlations with time of exposure (P = 0.005) and austenite-martensite phase transformation. The resistance of stainless steel orthodontic wires increases as the time in the mouth increases; this effect is attributed to the austenite-to-martensite transformation. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Stebner, Aaron; Padula, Santo A.; Noebe, Ronald D.
2008-01-01
Shape memory alloys (SMAs) have been used as actuators in many different industries since the discovery of the shape memory effect, but the use of SMAs as actuation devices in aeronautics has been limited due to the temperature constraints of commercially available materials. Consequently, work is being done at NASA's Glenn Research Center to develop new SMAs capable of being used in high temperature environments. One of the more promising high-temperature shape memory alloys (HTSMAs) is Ni19.5Ti50.5Pd25Pt5. Recent work has shown that this material is capable of being used in operating environments of up to 250 C. This material has been shown to have very useful actuation capabilities, demonstrating repeatable strain recoveries up to 2.5% in the presence of an externally applied load. Based on these findings, further work has been initiated to explore potential applications and alternative forms of this alloy, such as springs. Thus, characterization of Ni19.5Ti50.5Pd25Pt5 springs, including their mechanical response and how variations in this response correlate to changes in geometric parameters, are discussed. The effects of loading history, or training, on spring behavior were also investigated. A comparison of the springs with wire actuators is made and the benefits of using one actuator form as opposed to the other discussed. These findings are used to discuss design considerations for a surge-control mechanism that could be used in the centrifugal compressor of a T-700 helicopter engine.
Six-Year Effects of Two Late Spring Frosts on Appalachian Hardwoods
Everette D. Rast; Robert L. Brisbin; Robert L. Brisbin
1987-01-01
Severe late spring frosts can kill new shoots and leaves on commercial tree species at higher elevations. A previous short-term study has shown that the resulting defoliation and dieback does not seriously affect the radial growth or mortality of most species except American beech. In this study we found that defoliation, dieback, and radial growth increment were...
Pompei-Reynolds, Renée C; Kanavakis, Georgios
2014-08-01
The manufacturing process for copper-nickel-titanium archwires is technique sensitive. The primary aim of this investigation was to examine the interlot consistency of the mechanical properties of copper-nickel-titanium wires from 2 manufacturers. Wires of 2 sizes (0.016 and 0.016 × 0.022 in) and 3 advertised austenite finish temperatures (27°C, 35°C, and 40°C) from 2 manufacturers were tested for transition temperature ranges and force delivery using differential scanning calorimetry and the 3-point bend test, respectively. Variations of these properties were analyzed for statistical significance by calculating the F statistic for equality of variances for transition temperature and force delivery in each group of wires. All statistical analyses were performed at the 0.05 level of significance. Statistically significant interlot variations in austenite finish were found for the 0.016 in/27°C (P = 0.041) and 0.016 × 0.022 in/35°C (P = 0.048) wire categories, and in austenite start for the 0.016 × 0.022 in/35°C wire category (P = 0.01). In addition, significant variations in force delivery were found between the 2 manufacturers for the 0.016 in/27°C (P = 0.002), 0.016 in/35.0°C (P = 0.049), and 0.016 × 0.022 in/35°C (P = 0.031) wires. Orthodontic wires of the same material, dimension, and manufacturer but from different production lots do not always have similar mechanical properties. Clinicians should be aware that copper-nickel-titanium wires might not always deliver the expected force, even when they come from the same manufacturer, because of interlot variations in the performance of the material. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
1. Historic American Buildings Survey Original Water Color in Wells ...
1. Historic American Buildings Survey Original Water Color in Wells Fargo Bank Historical Museum Capt. Jean Jacques Vioget, Artist Spring of 1837 FIRST WATER COLOR OF SAN FRANCISCO (JACOB LEESE HOUSE IN CENTER) - San Francisco, Historic View, 1837, San Francisco, San Francisco County, CA
Curvature versus v-bends in a group B titanium T-loop spring.
Martins, Renato Parsekian; Buschang, Peter H; Viecilli, Rodrigo; dos Santos-Pinto, Ary
2008-05-01
To compare the system of forces acting on curvature and preactivated V-bends in titanium T-loop springs (TTLSs) made of 0.017- x 0.025-inch TMA (titanium molibdenium alloy) wire. Pictures of TTLSs preactivated by curvature and V-bends were inserted in the LOOP software program to design both TTLSs. Symmetry was assured using the program. Both TTLSs used the same amount (length) of wire and had the same angulation between their anterior and posterior extremities when passive. The loops were activated 7 mm, and forces and moments were registered after each 0.5 mm of deactivation. The brackets were at the same height, separated by 23 mm and angulated 0 degrees . The preactivated curvature TTLS delivered horizontal forces ranging from 34 gF to 456 gF, while the TTLS preactivated by V-bends delivered forces ranging from 54 gF to 517 gF. The forces decreased more (30 gF vs 33 gF) with every 0.5 mm of activation on the preactivated V-bend TTLS than on the preactivated curvature TTLS. Vertical forces were low and clinically insignificant for both TTLSs. The moment to force (MF) ratios were systematically higher on the preactivated curvature than on the preactivated V-bend TTLS (from 5.8 mm to 38.8 mm vs 4.7 mm to 28.3 mm). Although both loops show symmetrical moments in their anterior and posterior extremities and can be used for group B anchorage, the curvature preactivated TTLS delivers lower horizontal forces and higher MF ratios than the acute preactivated V-bend TTLS.
Grain-resolved analysis of localized deformation in nickel-titanium wire under tensile load.
Sedmák, P; Pilch, J; Heller, L; Kopeček, J; Wright, J; Sedlák, P; Frost, M; Šittner, P
2016-08-05
The stress-induced martensitic transformation in tensioned nickel-titanium shape-memory alloys proceeds by propagation of macroscopic fronts of localized deformation. We used three-dimensional synchrotron x-ray diffraction to image at micrometer-scale resolution the grain-resolved elastic strains and stresses in austenite around one such front in a prestrained nickel-titanium wire. We found that the local stresses in austenite grains are modified ahead of the nose cone-shaped buried interface where the martensitic transformation begins. Elevated shear stresses at the cone interface explain why the martensitic transformation proceeds in a localized manner. We established the crossover from stresses in individual grains to a continuum macroscopic internal stress field in the wire and rationalized the experimentally observed internal stress field and the topology of the macroscopic front by means of finite element simulations of the localized deformation. Copyright © 2016, American Association for the Advancement of Science.
Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J
2010-07-01
Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Advanced development of TFA-MOD coated conductors
NASA Astrophysics Data System (ADS)
Rupich, M. W.; Li, X.; Sathyamurthy, S.; Thieme, C.; Fleshler, S.
2011-11-01
American Superconductor is manufacturing 2G wire for initial commercial applications. The 2G wire properties satisfy the requirements for these initial projects; however, improvements in the critical current, field performance and cost are required to address the broad range of potential commercial and military applications. In order to meet the anticipated the performance and cost requirements, AMSC's R&D effort is focused on two major areas: (1) higher critical current and (2) enhanced flux pinning. AMSC's current 2G production wire, designed around a 0.8 μm thick YBCO layer deposited by a Metal Organic Deposition (MOD) process, carries a critical current in the range of 200-300 A/cm-w (77 K, sf). Achieving higher critical current requires increasing the thickness of the YBCO layer. This paper describes recent progress at AMSC on increasing the critical current of MOD-YBCO films using processes compatible with low-cost, high-rate manufacturing.
Lee, Moses; Guyton, Gregory P; Zahoor, Talal; Schon, Lew C
2016-01-01
As a standard open approach, the lateral oblique incision has been widely used for calcaneal displacement osteotomy. However, just as with other orthopedic procedures that use an open approach, complications, including wound healing problems and neurovascular injury in the heel, have been reported. To help avoid these limitations, a percutaneous technique using a Shannon burr for calcaneal displacement osteotomy was introduced. However, relying on a free-hand technique without direct visualization at the osteotomy site has been a major obstacle for this technique. To address this problem, we developed a technical tip using a reference Kirschner wire. A reference Kirschner wire technique provides a reliable and accurate guide for minimally invasive calcaneal displacement osteotomy. Also, the technique should be easy to learn for surgeons new to the procedure. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Springer, D. W.
Bell Helicopter Textron, Incorporated (BHTI) installed two Digital Equipment Corporation PDP-11 computers and an American Can Inc. Ink Jet printer in 1980 as the cornerstone of the Wire Harness Automated Manufacturing System (WHAMS). WHAMS is based upon the electrical assembly philosophy of continuous filament harness forming. This installation provided BHTI with a 3 to 1 return-on-investment by reducing wire and cable identification cycle time by 80 percent and harness forming, on dedicated layout tooling, by 40 percent. Yet, this improvement in harness forming created a bottle neck in connector assembly. To remove this bottle neck, BHTI has installed a prototype connector assembly cell that integrates the WHAMS' data base and innovative computer technologies to cut harness connector assembly cycle time. This novel connector assembly cell uses voice recognition, laser identification, and animated computer graphics to help the electrician in the correct assembly of harness connectors.
Seasons: The National Native American AIDS Prevention Center Quarterly. 1993.
ERIC Educational Resources Information Center
Rush, Andrea Green, Ed.
1993-01-01
The three 1993 issues of "Seasons" (the Spring/Summer issues are combined) address various aspects of dealing with Acquired Immune Deficiency Syndrome (AIDS) and Human Immunodeficiency Virus (HIV) among Native Americans. The Winter issue focuses on tuberculosis (TB) and its incidence and treatment among HIV-positive individuals.…
77 FR 65864 - North American Free-Trade Agreement (NAFTA), Article 1904 Binational Panel Reviews
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-31
..., respecting Carbon and Certain Alloy Steel Wire Rod from Canada, NAFTA Secretariat File Number USA-CDA-2008... cases. (Dongbu Steel Co. Ltd. v. United States, 635 F3d 1363 (Fed Cir. 2011); and JTEKT Corp. v. United...
Communication Gone Wired: Working toward a "Practiced" Cyberfeminism.
ERIC Educational Resources Information Center
Gruber, Sibylle
1999-01-01
Examines concepts of gender and race in virtual environments by presenting a case study of an African American woman's online personalities. Discusses how her online contributions in a college class discussion influenced her and the group's perspectives on violence and gender issues. (Author/LRW)
Three-Dimensional Wiring for Extensible Quantum Computing: The Quantum Socket
NASA Astrophysics Data System (ADS)
Béjanin, J. H.; McConkey, T. G.; Rinehart, J. R.; Earnest, C. T.; McRae, C. R. H.; Shiri, D.; Bateman, J. D.; Rohanizadegan, Y.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.; Mariantoni, M.
2016-10-01
Quantum computing architectures are on the verge of scalability, a key requirement for the implementation of a universal quantum computer. The next stage in this quest is the realization of quantum error-correction codes, which will mitigate the impact of faulty quantum information on a quantum computer. Architectures with ten or more quantum bits (qubits) have been realized using trapped ions and superconducting circuits. While these implementations are potentially scalable, true scalability will require systems engineering to combine quantum and classical hardware. One technology demanding imminent efforts is the realization of a suitable wiring method for the control and the measurement of a large number of qubits. In this work, we introduce an interconnect solution for solid-state qubits: the quantum socket. The quantum socket fully exploits the third dimension to connect classical electronics to qubits with higher density and better performance than two-dimensional methods based on wire bonding. The quantum socket is based on spring-mounted microwires—the three-dimensional wires—that push directly on a microfabricated chip, making electrical contact. A small wire cross section (approximately 1 mm), nearly nonmagnetic components, and functionality at low temperatures make the quantum socket ideal for operating solid-state qubits. The wires have a coaxial geometry and operate over a frequency range from dc to 8 GHz, with a contact resistance of approximately 150 m Ω , an impedance mismatch of approximately 10 Ω , and minimal cross talk. As a proof of principle, we fabricate and use a quantum socket to measure high-quality superconducting resonators at a temperature of approximately 10 mK. Quantum error-correction codes such as the surface code will largely benefit from the quantum socket, which will make it possible to address qubits located on a two-dimensional lattice. The present implementation of the socket could be readily extended to accommodate a quantum processor with a (10 ×10 )-qubit lattice, which would allow for the realization of a simple quantum memory.
ERIC Educational Resources Information Center
Zambrana, Ruth Enid; Hurtado, Sylvia
2016-01-01
This policy brief is based on the edited book "The Magic Key: The Educational Journey of Mexican Americans from K-12 to College and Beyond" (Zambrana & Hurtado, 2015a), which focuses on the experiences of Mexican Americans in education. Drawing from an interdisciplinary corpus of work, the authors move beyond the rhetoric of progress…
VIEW NORTH OF PRESTRESS TRACK CENTERHEMP STORAGE BUILDING 77 (1920) ...
VIEW NORTH OF PRE-STRESS TRACK CENTER-HEMP STORAGE BUILDING 77 (1920) ROPE WAREHOUSE 43 (1941) BEHIND IT STORAGE SHED 44 (1953) IN FRONT - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
3. This machine in building #7 plated the hooks used ...
3. This machine in building #7 plated the hooks used on the cross chains in tire chains, by the 'pean' or mechanical process. This process was replaced when coated wire was introduced. - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA
NASA USRP Internship Final Report
NASA Technical Reports Server (NTRS)
Black, Jesse A.
2010-01-01
The purpose of this report is to describe the body of work I have produced as a NASA USRP intern in the spring 2010. My mentor during this time was Richard Birr and I assisted him with many tasks in the advanced systems group in the engineering design lab at NASA's Kennedy space center. The main priority was and scenario modeling for the FAA's next generation air traffic control system and also developing next generation range systems for implementation at Kennedy space center. Also of importance was the development of wiring diagrams for the portable communications terminal for the desert rats program.
Sub-micro-Newton resolution thrust balance.
Hathaway, G
2015-10-01
Herein is described a sensitive vacuum balance for measuring the thrust produced by small (∼0.5 kg) thrusters typically employed in microsat station-keeping. The balance is based on a torsion design but incorporates jewel-pivot bearings instead of the more typical torsion spring bearings. Novel tilt control allows maintenance of true verticality of the bearing axis even while under vacuum. The low moment of inertia design allows it to measure small thrusts from high-voltage devices without direct wire conductor connections. Calibration by several means is described including use of a previously calibrated dielectric barrier discharge thruster.
Hall, Leslie C.; Hedges, Robert S.
1990-04-10
A cutting device is provided which is useful in trimming the jackets from semi-rigid coaxial cables and wire having a cutting bit and support attached to movable jaws. A thumbpiece is provided to actuate the opening of the jaws for receiving the cable to be trimmed, and a spring member is provided to actuate the closing of the jaws when thumbpiece is released. The cutting device utilizes one moving part during the cutting operation by using a rolling cut action. The nature of the jaws allows the cutting device to work in space having clearances less than 0.160 inches.
Comparison of Models of Stress Relaxation in Failure Analysis for Connectors under Long-term Storage
NASA Astrophysics Data System (ADS)
Zhou, Yilin; Wan, Mengru
2018-03-01
Reliability requirements of the system equipment under long-term storage are put forward especially for the military products, so that the connectors in the equipment also need long-term storage life correspondingly. In this paper, the effects of stress relaxation of the elastic components on electrical contact of the connectors in long-term storage process were studied from the failure mechanism and degradation models. A wire spring connector was taken as an example to discuss the life prediction method for electrical contacts of the connectors based on stress relaxation degradation under long -term storage.
The Selection of Friends by Preschool Children
ERIC Educational Resources Information Center
Romero, Sandy; Perez, Karla; Pasnak, Robert; Lehman, Elyse
2009-01-01
The friendships of 59 ethnically diverse (African American, European American, Latino, Middle Eastern, and West African) children enrolled in Head Start classes were assessed in the spring of the school year via a peer nomination technique and a roster rating method. Two types of behavior that earlier researchers found to be predictive of how well…
Diet and physical activity in African-American girls: Seasonal differences
USDA-ARS?s Scientific Manuscript database
Diet and physical activity (PA) may vary by season. Two 24-hour dietary recalls and 7 days of accelerometry were collected from 342 8-10 year-old African-American girls between January 2013 and October 2014. Season was based on time of data collection (fall, spring, winter, summer). Seasonal differe...
North Dakota Native American Essential Understandings
ERIC Educational Resources Information Center
North Dakota Department of Public Instruction, 2015
2015-01-01
In the spring of 2015, the North Dakota Department of Public Instruction brought together tribal Elders from across North Dakota to share stories, memories, songs, and wisdom in order to develop the North Dakota Native American Essential Understandings (NDNAEU) to guide the learning of both Native and non-Native students across the state. They…
75 FR 1401 - Buy American Exceptions Under the American Recovery and Reinvestment Act of 2009
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-11
... Wilkes-Barre Housing Authority for the purchase and installation of tank-less water heaters in the Mineral Springs Village and Boulevard Town Homes. FOR FURTHER INFORMATION CONTACT: Dominique G. Blom... goods (tank-less water heaters) are not produced in the U.S. in sufficient and reasonably available...
3. Historic American Buildings Survey E. W. Russell, Photographer, April ...
3. Historic American Buildings Survey E. W. Russell, Photographer, April 2, 1937 VIEW LOOKING S.W. SHOWING N.W. CORNER OF SECTION 'D' & 'E' ON THE RIGHT & NORTH ELEV. OF SMALL BUILDING WITH HALF OCTAGONAL BAYS ON LEFT. - Convent of the Visitation, 2300 Spring Hill Avenue, Mobile, Mobile County, AL
Seasonal effects of wind conditions on migration patterns of soaring American white pelican.
Gutierrez Illan, Javier; Wang, Guiming; Cunningham, Fred L; King, D Tommy
2017-01-01
Energy and time expenditures are determinants of bird migration strategies. Soaring birds have developed migration strategies to minimize these costs, optimizing the use of all the available resources to facilitate their displacement. We analysed the effects of different wind factors (tailwind, turbulence, vertical updrafts) on the migratory flying strategies adopted by 24 satellite-tracked American white pelicans (Pelecanus erythrorhynchos) throughout spring and autumn in North America. We hypothesize that different wind conditions encountered along migration routes between spring and autumn induce pelicans to adopt different flying strategies and use of these wind resources. Using quantile regression and fine-scale atmospheric data, we found that the pelicans optimized the use of available wind resources, flying faster and more direct routes in spring than in autumn. They actively selected tailwinds in both spring and autumn displacements but relied on available updrafts predominantly in their spring migration, when they needed to arrive at the breeding regions. These effects varied depending on the flying speed of the pelicans. We found significant directional correlations between the pelican migration flights and wind direction. In light of our results, we suggest plasticity of migratory flight strategies by pelicans is likely to enhance their ability to cope with the effects of ongoing climate change and the alteration of wind regimes. Here, we also demonstrate the usefulness and applicability of quantile regression techniques to investigate complex ecological processes such as variable effects of atmospheric conditions on soaring migration.
Seasonal effects of wind conditions on migration patterns of soaring American white pelican
Wang, Guiming; Cunningham, Fred L.; King, D. Tommy
2017-01-01
Energy and time expenditures are determinants of bird migration strategies. Soaring birds have developed migration strategies to minimize these costs, optimizing the use of all the available resources to facilitate their displacement. We analysed the effects of different wind factors (tailwind, turbulence, vertical updrafts) on the migratory flying strategies adopted by 24 satellite-tracked American white pelicans (Pelecanus erythrorhynchos) throughout spring and autumn in North America. We hypothesize that different wind conditions encountered along migration routes between spring and autumn induce pelicans to adopt different flying strategies and use of these wind resources. Using quantile regression and fine-scale atmospheric data, we found that the pelicans optimized the use of available wind resources, flying faster and more direct routes in spring than in autumn. They actively selected tailwinds in both spring and autumn displacements but relied on available updrafts predominantly in their spring migration, when they needed to arrive at the breeding regions. These effects varied depending on the flying speed of the pelicans. We found significant directional correlations between the pelican migration flights and wind direction. In light of our results, we suggest plasticity of migratory flight strategies by pelicans is likely to enhance their ability to cope with the effects of ongoing climate change and the alteration of wind regimes. Here, we also demonstrate the usefulness and applicability of quantile regression techniques to investigate complex ecological processes such as variable effects of atmospheric conditions on soaring migration. PMID:29065188
Pan, Caofeng; Luo, Zhixiang; Xu, Chen; Luo, Jun; Liang, Renrong; Zhu, Guang; Wu, Wenzhuo; Guo, Wenxi; Yan, Xingxu; Xu, Jun; Wang, Zhong Lin; Zhu, Jing
2011-08-23
We have developed a method combining lithography and catalytic etching to fabricate large-area (uniform coverage over an entire 5-in. wafer) arrays of vertically aligned single-crystal Si nanowires with high throughput. Coaxial n-Si/p-SiGe wire arrays are also fabricated by further coating single-crystal epitaxial SiGe layers on the Si wires using ultrahigh vacuum chemical vapor deposition (UHVCVD). This method allows precise control over the diameter, length, density, spacing, orientation, shape, pattern and location of the Si and Si/SiGe nanowire arrays, making it possible to fabricate an array of devices based on rationally designed nanowire arrays. A proposed fabrication mechanism of the etching process is presented. Inspired by the excellent antireflection properties of the Si/SiGe wire arrays, we built solar cells based on the arrays of these wires containing radial junctions, an example of which exhibits an open circuit voltage (V(oc)) of 650 mV, a short-circuit current density (J(sc)) of 8.38 mA/cm(2), a fill factor of 0.60, and an energy conversion efficiency (η) of 3.26%. Such a p-n radial structure will have a great potential application for cost-efficient photovoltaic (PV) solar energy conversion. © 2011 American Chemical Society
Nagura, Issei; Fujioka, Hiroyuki; Kurosaka, Masahiro; Mori, Hiroyuki; Mitani, Makoto; Ozaki, Akihiro; Fujii, Hideo; Nabeshima, Yuji
2012-01-01
Calcaneal avulsion fractures are not uncommon, and they are probably more likely in patients with osteoporosis. Closed manipulation for this type of fracture often fails to achieve acceptable reduction, and open reduction and internal fixation are usually required. However, open reduction and internal fixation with either a lag screw or Steinmann pins do not provide satisfactory fixation in patients with diabetes and elderly patients because of the presence of porotic bone. Levi described a tension band fixation system used to treat a calcaneal avulsion fracture using a simple technique performed with a transverse Kirschner wire through the os calcaneus, securing a figure-of-8 metal tension band wiring to the fragment. We report the successful treatment of 3 patients with calcaneal avulsion fractures using a modified tension band wiring technique, resulting in satisfactory recovery. Re-displacement of the fragment during the initial follow-up period was not reported, and bony union was achieved in all patients. We believe this technique is a useful surgical option for the treatment of calcaneal avulsion fractures. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Kennedy, Mike
2010-01-01
For the generation of people whose classroom memories consist of chalk squeaking on a blackboard, weather-beaten textbooks and a ready supply of sharpened No. 2 pencils, the resources available to students in many 21st-century American schools may seem unfamiliar, even amazing. Computer networks with access to the Internet--wired or wireless--have…
ERIC Educational Resources Information Center
Pool, Ithiel de Sola; Alexander, Herbert E.
The implications for American politics, public affairs broadcasting, and new reporting under different sorts of cable television (CATV) systems are considered in detail by this report. The authors believe that a contract carrier system is the most desirable, since it makes broadcast time most freely available and prevents the cable franchise owner…
ERIC Educational Resources Information Center
Cech, Scott J.
2006-01-01
Former Baltimore cop and teacher Ed Burns isn't a masochist. The writer-producer for "The Wire," a critically applauded HBO series about life and death on the streets of Baltimore, is just feverishly trying to save public schools. He thinks American education is hopelessly screwed up, but that it's also the country's only hope. So it…
75 FR 41529 - Petitions for Modification
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-16
... number'' on the subject line, by any of the following methods: 1. Electronic Mail: Standards-Petitions... permissible pump trailing cables will not be smaller than 10 American Wire Gauge (AWG); (4) all circuit... will have an instantaneous trip unit calibrated to trip at 70 percent of phase-to-phase short-circuit...
75 FR 12793 - Petitions for Modification
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-17
... number'' on the subject line, by any of the following methods: 1. Electronic Mail: Standards-Petitions... cables will be no smaller than 10 American Wire Gauge (AWG); (4) all circuit breakers used to protect... unit calibrated to trip at 70% of phase to phase short circuit current. The trip setting of these...
Stability of beta-titanium T-loop springs preactivated by gradual curvature
Caldas, Sergei Godeiro Fernandes Rabelo; Martins, Renato Parsekian; de Araújo, Marcela Emílio; Galvão, Marília Regalado; da Silva, Roberto Soares; Martins, Lídia Parsekian
2017-01-01
ABSTRACT Objective: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced. PMID:29364381
Stability of beta-titanium T-loop springs preactivated by gradual curvature.
Caldas, Sergei Godeiro Fernandes Rabelo; Martins, Renato Parsekian; Araújo, Marcela Emílio de; Galvão, Marília Regalado; Silva Júnior, Roberto Soares da; Martins, Lídia Parsekian
2017-01-01
Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced.
Bottled water, spas, and early years of water chemistry
Back, William; Landa, Edward R.; Meeks, Lisa
1995-01-01
Although hot springs have been used and enjoyed for thousands of years, it was not until the late 1700s that they changed the course of world civilization by being the motivation for development of the science of chemistry. The pioneers of chemistry such as Priestley, Cavendish, Lavoisier, and Henry were working to identify and generate gases, in part, to determine their role in carbonated beverages. In the 18th century, spas in America were developed to follow the traditional activities of popular European spas. However, they were to become a dominant political and economic force in American history on three major points: (1) By far the most important was to provide a place for the leaders of individual colonies to meet and discuss the need for separation from England and the necessity for the Revolutionary War; (2) the westward expansion of the United States was facilitated by the presence of hot springs in many locations that provided the economic justification for railroads and settlement; and (3) the desire for the preservation of hot springs led to the establishment of the National Park Service. Although mineral springs have maintained their therapeutic credibility in many parts of the world, they have not done so in the United States. We suggest that the American decline was prompted by: (1) the establishment of The Johns Hopkins School of Medicine in 1893; (2) enactment of the Pure Food and Drug Act of 1907; and (3) the remarkable achievement of providing safe water supplies for American cities by the end of the 1920s. The current expanding market for bottled water is based in part on bottled water being an alternative beverage Ito alcohol and sweetened drinks and the inconsistent palatability and perceived health hazards of some tap waters.
Xu, He; Li, Haiyan; Ke, Qinfei; Chang, Jiang
2015-04-29
The development of vascular scaffolds with controlled mechanical properties and stimulatory effects on biological activities of endothelial cells still remains a significant challenge to vascular tissue engineering. In this work, we reported an innovative approach to prepare a new type of vascular scaffolds with anisotropically and heterogeneously aligned patterns using electrospinning technique with unique wire spring templates, and further investigated the structural effects of the patterned electrospun scaffolds on mechanical properties and angiogenic differentiation of human umbilical vein endothelial cells (HUVECs). Results showed that anisotropically aligned patterned nanofibrous structure was obtained by depositing nanofibers on template in a structurally different manner, one part of nanofibers densely deposited on the embossments of wire spring and formed cylindrical-like structures in the transverse direction, while others loosely suspended and aligned along the longitudinal direction, forming a three-dimensional porous microstructure. We further found that such structures could efficiently control the mechanical properties of electrospun vascular scaffolds in both longitudinal and transverse directions by altering the interval distances between the embossments of patterned scaffolds. When HUVECs were cultured on scaffolds with different microstructures, the patterned scaffolds distinctively promoted adhesion of HUVECs at early stage and proliferation during the culture period. Most importantly, cells experienced a large shape change associated with cell cytoskeleton and nuclei remodeling, leading to a stimulatory effect on angiogenesis differentiation of HUVECs by the patterned microstructures of electrospun scaffolds, and the scaffolds with larger distances of intervals showed a higher stimulatory effect. These results suggest that electrospun scaffolds with the anisotropically and heterogeneously aligned patterns, which could efficiently control the mechanical properties and bioactivities of the scaffolds, might have great potential in vascular tissue engineering application.
Recent Salmon Declines: A Result of Lost Feeding Opportunities Due to Bad Timing?
Chittenden, Cedar M.; Jensen, Jenny L. A.; Ewart, David; Anderson, Shannon; Balfry, Shannon; Downey, Elan; Eaves, Alexandra; Saksida, Sonja; Smith, Brian; Vincent, Stephen; Welch, David; McKinley, R. Scott
2010-01-01
As the timing of spring productivity blooms in near-shore areas advances due to warming trends in global climate, the selection pressures on out-migrating salmon smolts are shifting. Species and stocks that leave natal streams earlier may be favoured over later-migrating fish. The low post-release survival of hatchery fish during recent years may be in part due to static release times that do not take the timing of plankton blooms into account. This study examined the effects of release time on the migratory behaviour and survival of wild and hatchery-reared coho salmon (Oncorhynchus kisutch) using acoustic and coded-wire telemetry. Plankton monitoring and near-shore seining were also conducted to determine which habitat and food sources were favoured. Acoustic tags (n = 140) and coded-wire tags (n = 266,692) were implanted into coho salmon smolts at the Seymour and Quinsam Rivers, in British Columbia, Canada. Differences between wild and hatchery fish, and early and late releases were examined during the entire lifecycle. Physiological sampling was also carried out on 30 fish from each release group. The smolt-to-adult survival of coho salmon released during periods of high marine productivity was 1.5- to 3-fold greater than those released both before and after, and the fish's degree of smoltification affected their downstream migration time and duration of stay in the estuary. Therefore, hatchery managers should consider having smolts fully developed and ready for release during the peak of the near-shore plankton blooms. Monitoring chlorophyll a levels and water temperature early in the spring could provide a forecast of the timing of these blooms, giving hatcheries time to adjust their release schedule. PMID:20805978
ERIC Educational Resources Information Center
American Indian Journal, 1979
1979-01-01
In an interview, Senator Mark Hatfield discusses Indian concerns in the 96th Congress. He addresses the role and future of the Senate Indian Affairs Committee, Congressional attitudes towards American Indians, the Indian Health Service, the "Boldt" Supreme Court decision, the Warm Springs Tribe, and the Institute for American Indian…
American Government: An Introduction Using MicroCase with Distance Learners.
ERIC Educational Resources Information Center
Rosberg, William H.
In spring 1997, a project used MicroCase, a computer-based statistical analysis and data retrieval system, to offer an American Government class to distance students at Iowa's Kirkwood Community College (KCC). Students participated in the course at one of the college's 10 learning centers via a statewide fiber-optic network. MicroCase provided the…
American Political Leaders. American Biographies.
ERIC Educational Resources Information Center
Wilson, Richard L.
The men and women profiled in this book spring from diverse backgrounds. Each was elected or appointed to his or her position, and all have wielded political leadership in ways that have had a profound impact on the lives of their fellow citizens. The book highlights the lives and achievements of 250+ individuals with the qualities to have become…
Racial Integration in American Neighborhoods: A Comparative Survey.
ERIC Educational Resources Information Center
Bradburn, Norman M.; And Others
An estimated 36 million Americans--or 19 percent of the population--lived in racially integrated neighborhoods in the spring of 1967. Yet, the number of Negroes living in such neighborhoods tended to be small in comparison with the number of whites. The research operations for this study, which began in the autumn of 1966, were divided into three…
Food Buying Practices of Mexican Americans in East Los Angeles.
ERIC Educational Resources Information Center
Lewis, Jane S.; And Others
As part of a pilot study of the nutritional status of Mexican American preschool children attending Head Start in East Los Angeles in the spring of 1969, questions were asked concerning their families' buying and food practices. This paper reports on the information obtained from the 21 questionnaires which were returned. Answers to the following…
Key Effectiveness Indicators (KEI Report): American River College Five-Year Profile, 1997-2002.
ERIC Educational Resources Information Center
Barr, Jim; Higgins, Jim; Grill, Cathie
This document addresses the key effectiveness indicators for American River College between 1997-2002. The figures are presented in table and graph format and some figures shown present detailed enrollment numbers for fall, spring, and summer while in other figures terms are collapsed into one full academic year. Dramatic enrollment gains were…
1985 Salaries: Society Membership Survey. American Institute of Physics Report.
ERIC Educational Resources Information Center
Skelton, W. Keith; And Others
Variation in the salaries of U.S. and Canadian members of the American Institute of Physics are examined, based on a spring 1985 survey. Graphics highlighting some of the patterns are presented, along with detailed tables and brief summary text. The overall response rate was 65%. Tables cover salaries and geographic location for Ph.D.s salaries…
NASA Astrophysics Data System (ADS)
Chiou, Jin-Chern; Hung, Chen-Chun; Lin, Chun-Ying
2010-07-01
This work presents a MEMS-based image stabilizer applied for anti-shaking function in photographic cell phones. The proposed stabilizer is designed as a two-axis decoupling XY stage 1.4 × 1.4 × 0.1 mm3 in size, and adequately strong to suspend an image sensor for anti-shaking photographic function. This stabilizer is fabricated by complex fabrication processes, including inductively coupled plasma (ICP) processes and flip-chip bonding technique. Based on the special designs of a hollow handle layer and a corresponding wire-bonding assisted holder, electrical signals of the suspended image sensor can be successfully sent out with 32 signal springs without incurring damage during wire-bonding packaging. The longest calculated traveling distance of the stabilizer is 25 µm which is sufficient to resolve the anti-shaking problem in a three-megapixel image sensor. Accordingly, the applied voltage for the 25 µm moving distance is 38 V. Moreover, the resonant frequency of the actuating device with the image sensor is 1.123 kHz.
Ogi, Hirotsugu; Nagai, Hironao; Naga, Hironao; Fukunishi, Yuji; Hirao, Masahiko; Nishiyama, Masayoshi
2009-10-01
We develop a highly sensitive quartz crystal microbalance (QCM) biosensor with a fundamental resonance frequency of 170 MHz. A naked AT-cut quartz plate of 9.7 microm thick is set in a sensor cell. Its shear vibration is excited by the line wire, and the vibration signals are detected by the other line wire, achieving the noncontacting measurement of the resonance frequency. The mass sensitivity of the 170 MHz QCM biosensor is 15 pg/(cm2 Hz), which is better than that of a conventional 5 MHz QCM by 3 orders of magnitude. Its high sensitivity is confirmed by detecting human immunoglobulin G (hIgG) via Staphylococcus protein A immobilized nonspecifically on both surfaces of the quartz plate. The detection limit is 0.5 pM. Limitation of the high-frequency QCM measurement is then theoretically discussed with a continuum mechanics model for a plate with point masses connected by elastic springs. The result indicates that a QCM measurement will break down at frequencies one-order-of-magnitude higher than the local resonance frequency at specific binding cites.
AC application of second generation HTS wire
NASA Astrophysics Data System (ADS)
Thieme, C. L. H.; Gagnon, K.; Voccio, J.; Aized, D.; Claassen, J.
2008-02-01
For the production of Second Generation (2G) YBCO High Temperature Superconductor wire American Superconductor uses a wide-strip MOD-YBCO/RABiTSTM process, a low-cost approach for commercial manufacturing. It can be engineered with a high degree of flexibility to manufacture practical 2G conductors with architectures and properties tailored for specific applications and operating conditions. For ac applications conductor and coil design can be geared towards low hysteretic losses. For applications which experience high frequency ac fields, the stabilizer needs to be adjusted for low eddy current losses. For these applications a stainless-steel laminate is used. An example is a Low Pass Filter Inductor which was developed and built in this work.
2005-01-01
Assessing and understanding the health needs and capacities of college students is paramount to creating healthy campus communities. The American College Health Association-National College Health Assessment (ACHA-NCHA) is a survey instrument developed by the American College Health Association (ACHA) in 1998 to assist institutions of higher education in achieving this goal. The ACHA-NCHA contains approximately 300 questions assessing student health status and health problems, risk and protective behaviors, access to health information, impediments to academic performance, and perceived norms across a variety of content areas, including injury prevention; personal safety and violence; alcohol, tobacco, and other drug use; sexual health; weight, nutrition, and exercise; and mental health. Twice a year, ACHA compiles aggregate data from institutions using the ACHA-NCHA to provide a reference group for data comparison. A portion of the data from the Spring 2003 Reference Group is provided in this article for use by professionals, researchers, institutions, departments, and organizations invested in advancing the health of college students.
Tropical rotation crops influence nematode densities and vegetable yields.
McSorley, R; Dickson, D W; de Brito, J A; Hochmuth, R C
1994-09-01
The effects of eight summer rotation crops on nematode densities and yields of subsequent spring vegetable crops were determined in field studies conducted in north Florida from 1991 to 1993. The crop sequence was as follows: (i) rotation crops during summer 1991; (ii) cover crop of rye (Secale cereale) during winter 1991-92; (iii) 'Lemondrop L' squash (Cucurbita pepo) during spring 1992; (iv) rotation crops during summer 1992; (v) rye during winter 1992-93; (vi) 'Classic' eggplant (Solanum melongena) during spring 1993. The eight summer crop rotation treatments were as follows: 'Hale' castor (Ricinus communis), velvetbean (Mucuna deeringiana), sesame (Sesamum indicum), American jointvetch (Aeschynomene americana), weed fallow, 'SX- 17' sorghum-sudangrass (Sorghum bicolor x S. sudanense), 'Kirby' soybean (Glycine max), and 'Clemson Spineless' okra (Hibiscus esculentus) as a control. Rotations with castor, velvetbean, American jointvetch, and sorghum-sudangrass were most effective in maintaining the lowest population densities of Meloidogyne spp. (a mixture of M. incognita race 1 and M. arenaria race 1), but Paratrichodorus minor built up in the sorghum-sudangrass rotation. Yield of squash was lower (P = 0.05) following sorghum-sudangrass than after any of the other treatments except fallow. Yield of eggplant was greater (P = 0.05) following castor, sesame, or American jointvetch than following okra or fallow. Several of the rotation crops evaluated here may be useful for managing nematodes in the field and for improving yields of subsequent vegetable crops.
Design and preliminary evaluation of an exoskeleton for upper limb resistance training
NASA Astrophysics Data System (ADS)
Wu, Tzong-Ming; Chen, Dar-Zen
2012-06-01
Resistance training is a popular form of exercise recommended by national health organizations, such as the American College of Sports Medicine (ACSM) and the American Heart Association (AHA). This form of training is available for most populations. A compact design of upper limb exoskeleton mechanism for homebased resistance training using a spring-loaded upper limb exoskeleton with a three degree-of-freedom shoulder joint and a one degree-of-freedom elbow joint allows a patient or a healthy individual to move the upper limb with multiple joints in different planes. It can continuously increase the resistance by adjusting the spring length to train additional muscle groups and reduce the number of potential injuries to upper limb joints caused by the mass moment of inertia of the training equipment. The aim of this research is to perform a preliminary evaluation of the designed function by adopting an appropriate motion analysis system and experimental design to verify our prototype of the exoskeleton and determine the optimal configuration of the spring-loaded upper limb exoskeleton.
36 CFR Appendix B to Part 1191 - Americans With Disabilities Act: Scoping
Code of Federal Regulations, 2014 CFR
2014-07-01
... of Sport Activity. That portion of a room or space where the play or practice of a sport occurs..., receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency, infrared, or direct-wired equipment. Boarding Pier. A portion...
Russia Still Matters: Strategic Challenges and Opportunities for the Obama Administration
2013-03-01
turn to the presidency and the battle down to the wire in the American elections put bilateral relations on the back burner . The exceptions were...Putin used the September 2012 Asia-Pacific Eco - nomic Cooperation (APEC) summit in Vladivostok to underscore Russia’s presence and role in the region
77 FR 26318 - Duke Energy Carolinas, LLC., Oconee Nuclear Station, Units 1, 2, and 3 Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-03
... the Transition Range,'' and American Society of Mechanical Engineers (ASME), Boiler and Pressure... heat numbers; (2) applied chemistry factors greater than 167 [deg]F (the weld wire heat- specific chemical composition, via the methodology of RG 1.99, Revision 2, indicated that higher chemistry factors...
78 FR 73239 - Small Generator Interconnection Agreements and Procedures
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-05
... distributed resources.\\35\\ Public Interest Organizations go on to state that: \\29\\ See, e.g., American Wind... Society and Wind on the Wires are referred to collectively as Public Interest Organizations in this Final...\\ Similarly, installed wind generation with a capacity of 20 MW or less has increased in the contiguous United...
49 CFR 393.7 - Matter incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications... Association, WSTDA-T1, 1998, incorporation by reference approved for § 393.104(e). (21) Wire Rope Users Manual...
49 CFR 393.7 - Matter incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications... Association, WSTDA-T1, 1998, incorporation by reference approved for § 393.104(e). (21) Wire Rope Users Manual...
ERIC Educational Resources Information Center
Teaching Tolerance, 2010
2010-01-01
In this article, the author shares her family's sad experience after being thrown in internment camps as part of the enforcement of the Executive Order 9066 following the Japanese's bombardment of Pearl Harbor. Japanese Americans were evacuated from their homes. In one day everything they had was stolen--even their pictures. It broke her mother's…
Kingsbury, J.A.
2008-01-01
Two karst springs in the Mississippian Carbonate Aquifer of northern Alabama were sampled between March 1999 and March 2001 to characterize the variability in concentration of nitrate, pesticides, selected pesticide degradates, water temperature, and inorganic constituents. Water temperature and inorganic ion data for McGeehee Spring indicate that this spring represents a shallow flow system with a relatively short average ground-water residence time. Water issuing from the larger of the two springs, Meridianville Spring, maintained a constant temperature, and inorganic ion data indicate that this water represents a deeper flow system having a longer average ground-water residence time than McGeehee Spring. Although water-quality data indicate differing short-term responses to rainfall at the two springs, the seasonal variation of nitrate and pesticide concentrations generally is similar for the two springs. With the exception of pesticides detected at low concentrations, the coefficient of variation for most constituent concentrations was less than that of flow at both springs, with greater variability in concentration at McGeehee Spring. Degradates of the herbicides atrazine and fluometuron were detected at concentrations comparable to or greater than the parent pesticides. Decreases in concentration of the principal degradate of fluometuron from about July to November indicate that the degradation rate may decrease as fluometuron (demethylfluometuron) moves deeper into the soil after application. Data collected during the study show that from about November to March when recharge rates increase, nitrate and residual pesticides in the soil, unsaturated zone, and storage within the aquifer are transported to the spring discharges. Because of the increase in recharge, fluometuron loads discharged from the springs during the winter were comparable to loads discharged at the springs during the growing season. ?? 2008 American Water Resources Association.
The false spring of 2012, earliest in North American record
Ault, T.R.; Henebry, G.M.; de Beurs, K. M.; Schwartz, M.D.; Betancourt, Julio L.; Moore, David
2013-01-01
Phenology - the study of recurring plant and animal life cycle stages, especially their timing and relationships with weather and climate - is becoming an essential tool for documenting, communicating, and anticipating the consequences of climate variability and change. For example, March 2012 broke numerous records for warm temperatures and early flowering in the United States [Karl et al., 2012; Elwood et al., 2013]. Many regions experienced a “false spring,” a period of weather in late winter or early spring sufficiently mild and long to bring vegetation out of dormancy prematurely, rendering it vulnerable to late frost and drought.As global climate warms, increasingly warmer springs may combine with the random climatological occurrence of advective freezes, which result from cold air moving from one region to another, to dramatically increase the future risk of false springs, with profound ecological and economic consequences [e.g., Gu et al., 2008; Marino et al., 2011; Augspurger, 2013]. For example, in the false spring of 2012, an event embedded in long-term trends toward earlier spring [e.g., Schwartz et al., 2006], the frost damage to fruit trees totaled half a billion dollars in Michigan alone, prompting the federal government to declare the state a disaster area [Knudson, 2012].
Z pinches as intense x-ray sources for high-energy density physics applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzen, M.K.
1997-05-01
Fast Z-pinch implosions can efficiently convert the stored electrical energy in a pulsed-power accelerator into x rays. These x rays are produced when an imploding cylindrical plasma, driven by the magnetic field pressure associated with very large axial currents, stagnates upon the cylindrical axis of symmetry. On the Saturn pulsed-power accelerator [R. B. Spielman {ital et al.}, in {ital Proceedings of the 2nd International Conference on Dense Z Pinches}, Laguna Beach, CA, 1989, edited by N. R. Pereira, J. Davis, and N. Rostoker (American Institute of Physics, New York, 1989), p. 3] at Sandia National Laboratories, for example, currents ofmore » 6{endash}8 MA with a rise time of less than 50 ns are driven through cylindrically symmetric loads, producing implosion velocities as high as 10{sup 8}cm/s and x-ray energies exceeding 400 kJ. Hydromagnetic Rayleigh{endash}Taylor instabilities and cylindrical load symmetry are critical, limiting factors in determining the assembled plasma densities and temperatures, and thus in the x-ray energies and pulse widths that can be produced on these accelerators. In recent experiments on the Saturn accelerator, these implosion nonuniformities have been minimized by using wire arrays with as many as 192 wires. Increasing the wire number produced significant improvements in the pinched plasma quality, reproducibility, and x-ray output power. X-ray pulse widths of less than 5 ns and peak powers of 75{plus_minus}10TW have been achieved with arrays of 120 tungsten wires. Similar loads have recently been fielded on the Particle Beam Fusion Accelerator (PBFA II), producing x-ray energies in excess of 1.8 MJ at powers in excess of 160 TW. These intense x-ray sources offer the potential for performing many new basic physics and fusion-relevant experiments. {copyright} {ital 1997 American Institute of Physics.}« less
Dalili Kajan, Zahra; Khademi, Jalil; Alizadeh, Ahmad; Babaei Hemmaty, Yasamin; Atrkar Roushan, Zahra
2015-09-01
This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1 -weighted images, fast spin-echo T2 -weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.
Khademi, Jalil; Alizadeh, Ahmad; Babaei Hemmaty, Yasamin; Atrkar Roushan, Zahra
2015-01-01
Purpose This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Materials and Methods A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Results Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. Conclusion With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires. PMID:26389058
Evaluation of the MSFC facsimile camera system as a tool for extraterrestrial geologic exploration
NASA Technical Reports Server (NTRS)
Wolfe, E. W.; Alderman, J. D.
1971-01-01
Utility of the Marshall Space Flight (MSFC) facsimile camera system for extraterrestrial geologic exploration was investigated during the spring of 1971 near Merriam Crater in northern Arizona. Although the system with its present hard-wired recorder operates erratically, the imagery showed that the camera could be developed as a prime imaging tool for automated missions. Its utility would be enhanced by development of computer techniques that utilize digital camera output for construction of topographic maps, and it needs increased resolution for examining near field details. A supplementary imaging system may be necessary for hand specimen examination at low magnification.
ERIC Educational Resources Information Center
Al-Asfour, Ahmed; Bryant, Carol
2011-01-01
This research examined the perceptions of Lakota Native American students taking a Business online course at the Oglala Lakota College on the Pine Ridge Reservation. The study was conducted in the fall of 2010 and spring of 2011. The themes found in this study were flexibility, transportation, communication, and technical support. Furthermore, the…
Chippewa Indians: A Native American Curriculum Unit for the Third Grade. NATAM XIII.
ERIC Educational Resources Information Center
Kocur, Darlene
The document reports on an extension course taken in the spring of 1970 by public school teachers in the Columbia Heights Public School System via the University of Minnesota. The course, on American Indian education, included the usual on-campus requirements, as well as several lectures by guest Indians. Additionally, each teacher who enrolled in…
ERIC Educational Resources Information Center
Wilson, Travis M.; Rodkin, Philip C.
2013-01-01
This study examined whether ethnic segregation is concurrently (fall) and prospectively (fall to spring) associated with social status among 4th- and 5th-grade African American and European American children ("n" = 713, ages 9-11 years). Segregation measures were (a) same-ethnicity favoritism in peer affiliations and (b) cross-ethnicity…
ERIC Educational Resources Information Center
Wilson, Travis M.; Rodkin, Philip C.; Ryan, Allison M.
2014-01-01
This study examined whether social goal orientation (i.e., demonstration-approach, demonstration--avoid, and social development goals) predicts changes in ethnic segregation among 4th and 5th grade African American and European American children (n = 713, ages 9-11 years) from fall to spring. Segregation measures were (a) same-ethnicity favoritism…
ERIC Educational Resources Information Center
Housman, Naomi G.; Martinez, Monica R.
This Spring 2002 issue of the occasional paper, CSR Connection, reports on information that builds the capacity of schools to raise the academic achievement of all students. The success of English language learners and Native American students in U.S. public schools has been, and continues to be, impeded by deep "disconnects" between schools and…
ERIC Educational Resources Information Center
Murray, Corey
2013-01-01
When American Association of Community Colleges (AACC) President and CEO Walter G. Bumphus announced the release of AACC's "Reclaiming the American Dream: Community Colleges and the Nation's Future" report last spring, he made a promise to community college leaders: This report would not sit idle on the shelf. As community college…
U.S. Students Study Abroad in the Middle East/North Africa: Factors Influencing Growing Numbers
ERIC Educational Resources Information Center
Lane-Toomey, Cara K.; Lane, Shannon R.
2013-01-01
The political events of the last decade and the Arab Spring have made it more important than ever for Americans to understand the language, culture, and history of the Middle East/North Africa (MENA) region. Study abroad is one important method that can significantly increase American students' understanding of the Arabic language and the culture…
1982 Salaries. Society Membership Survey. American Institute of Physics Report.
ERIC Educational Resources Information Center
Skelton, W. Keith; And Others
Variation and changes in the salaries of members of the American Institute of Physics are examined. Graphics highlighting some of the patterns are presented, along with detailed tables and brief summary text. The data are based on a sample survey of the U.S. members conducted in spring 1982. The overall response rate was 67 percent. Tables cover…
Fatigue testing of controlled memory wire nickel-titanium rotary instruments.
Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus
2011-07-01
To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys to manufacture NiTi files and developed new manufacturing processes. This study was aimed to examine the fatigue behavior of NiTi instruments from a novel controlled memory NiTi wire (CM Wire). Instruments of ProFile, Typhoon (TYP), Typhoon CM (TYP CM), DS-SS0250425NEYY (NEYY), and DS-SS0250425NEYY CM (NEYY CM) (DS Dental, Johnson City, TN) all size 25/.04 were subjected to rotational bending at the curvature of 35° and 45° in air at the temperature of 23° ± 2°C, and the number of revolutions to fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites, the percentage of dimple area to the whole fracture cross-section, and the surface strain amplitude (ε(a)) were noted. The new alloy yielded an improvement of over three to eight times in N(f) of CM files than that of conventional NiTi files (P < .05). The vast majority of CM instruments (50%-92%) showed multiple crack origins, whereas most instruments made from conventional NiTi wire (58%-100%) had one crack origin. The values of the fraction area occupied by the dimple region were significantly smaller on CM NiTi instruments compared with conventional NiTi instruments (P < .01). The square (NEYY CM) versus the triangular (TYP CM) configuration showed a significantly different lifetime on CM wire at both curvatures (P < .01). The material property had a substantial impact on fatigue lifetime. Instruments made from CM Wire had a significantly higher N(f) and lower surface strain amplitude than the conventional NiTi wire files with identical design. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus
2012-03-01
This study examined the fatigue behavior of 2 types of nickel-titanium (NiTi) instruments made from a novel controlled memory NiTi wire (CM wire) under various environment conditions. Three conventional superelastic NiTi instruments of ProFile (Dentsply Maillefer, Ballaigues, Switzerland), Typhoon (Clinician's Choice Dental Products, New Milford, CT), and DS-SS0250425NEYY (Clinician's Choice Dental Products) and 2 new CM wire instruments of Typhoon CM and DS-SS0250425NEYY CM were subjected to rotational bending at the curvature of 35° in air, deionized water, 17% EDTA, or deionized water after immersion in 6% sodium hypochlorite for 25 minutes, and the number of revolutions of fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites and the percentage of dimple area to the whole fracture cross-section were noted. Two new CM Wire instruments yielded an improvement of >4 to 9 times in N(f) than conventional NiTi files with the same design under various environments (P < .05). The fatigue life of 3 conventional superelastic NiTi instruments was similar under various environments, whereas the N(f) of 2 new CM Wire instruments was significantly longer in liquid media than in air (P < .05). The vast majority of CM instruments showed multiple crack origins, whereas most instruments made from conventional NiTi wire had one crack origin. The values of the area fraction occupied by the dimple region were significantly smaller on CM NiTi instruments than in conventional NiTi instruments under various environments (P < .05). Within the limitations of this study, the type of NiTi metal alloy (CM files vs conventional superelastic NiTi files) influences the cyclic fatigue resistance under various environments. The fatigue life of CM instruments is longer in liquid media than in air. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Influence of stress and phase on corrosion of a superelastic nickel-titanium orthodontic wire.
Segal, Nadav; Hell, Jess; Berzins, David W
2009-06-01
The purpose of this investigation was to study the effect of stress and phase transformation on the corrosion properties of a superelastic nickel-titanium orthodontic wire. The phase transformation profiles of superelastic nickel-titanium (Sentalloy, GAC International, Bohemia, NY) and beta-titanium (TMA, Ormco, Orange, Calif) archwires were analyzed by using differential scanning calorimetry. The force/deflection behavior of the wires at 37 degrees C was measured in a 3-point bending test per modified American Dental Association specification no. 32. Electrochemical testing consisted of monitoring the open circuit potential (OCP) for 2 hours followed by polarization resistance and cyclic polarization tests on archwire segments engaged in a 5-bracket simulation apparatus with bend deflections of 0.75, 1.5, or 3 mm in artificial saliva at 37 degrees C. Nondeflected segments were also tested. Sentalloy was additionally examined for bending and corrosion at 5 degrees C, where it exists as martensite and is devoid of stress-induced phase transformation. OCP at 2 hours and corrosion current density (i(corr)) were analyzed by using ANOVA and Tukey tests (alpha = .05) (n = 10 per deflection). Significant differences (P < 0.05) in OCP with deflection were found for the TMA and the Sentalloy wires at 5 degrees C, but not for Sentalloy at 37 degrees C. Significant differences (P < 0.05) in i(corr) with deflection were also observed. All 3 wire groups had their lowest mean i(corr) values when not deflected. The i(corr) for superelastic Sentalloy (37 degrees C) peaked at 0.75 mm deflection before the wire's stress-induced phase transformation point and then decreased with further deflection and transformation. The i(corr) values for TMA and Sentalloy at 5 degrees C, both of which do not undergo phase transformation with deformation, continuously increased from 0 to 1.5 mm deflection before decreasing at the 3.0-mm deflection. Stress increased the corrosion rate in nickel-titanium and beta-titanium orthodontic wires. Alterations in stress/strain associated with phase transformation in superelastic nickel-titanium might alter the corrosion rate in ways different from wires not undergoing phase transformation.
VIEW SOUTH FROM HAMILTON AVENUE BUILDING 25 LEFT; BUILDING 32 ...
VIEW SOUTH FROM HAMILTON AVENUE BUILDING 25 LEFT; BUILDING 32 MACHINE SHOP (1890) LEFT CENTER BUILDING 31 RIGGER'S SHOP (1890) CENTER BUILDING 28 BLACKSMITH SHOP (1885) RIGHT CENTER; BUILDING 27 PATTERN SHOP (1853) RIGHT - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
Dynamic behavior and deformation analysis of the fish cage system using mass-spring model
NASA Astrophysics Data System (ADS)
Lee, Chun Woo; Lee, Jihoon; Park, Subong
2015-06-01
Fish cage systems are influenced by various oceanic conditions, and the movements and deformation of the system by the external forces can affect the safety of the system itself, as well as the species of fish being cultivated. Structural durability of the system against environmental factors has been major concern for the marine aquaculture system. In this research, a mathematical model and a simulation method were presented for analyzing the performance of the large-scale fish cage system influenced by current and waves. The cage system consisted of netting, mooring ropes, floats, sinkers and floating collar. All the elements were modeled by use of the mass-spring model. The structures were divided into finite elements and mass points were placed at the mid-point of each element, and mass points were connected by springs without mass. Each mass point was applied to external and internal forces, and total force was calculated in every integration step. The computation method was applied to the dynamic simulation of the actual fish cage systems rigged with synthetic fiber and copper wire simultaneously influenced by current and waves. Here, we also tried to find a relevant ratio between buoyancy and sinking force of the fish cages. The simulation results provide improved understanding of the behavior of the structure and valuable information concerning optimum ratio of the buoyancy to sinking force according to current speeds.
1983-05-01
REPORT, SECTION 7 CONSULTATION, FN WARM SPRINGS DAM AND LAKE SONOMA, SONOMA COUNTY , F P IN CALIFORNIA 6. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(s) 8...regarding the American Peregrine Falcon (Falco peregrInus anatum) and its critical habitat (about 13,300 acres in Sonoma County , California) in the 29 May...federally owned historic resources. Actions to be undertaken will not impair historic properties. e. Sonoma County General Plan. This County Plan is a
ERIC Educational Resources Information Center
American School Band Directors Association, Newark, OH.
The guide, one in a series of committee reports relating to school band performance, organization, and equipment needs, discusses acoustical problems inherent to the clarinet. The report is presented in five sections. Section I summarizes findings of an American School Band Directors' Association (ASBDA) clarinet testing committee. A major finding…
John G. Kie; Bruce K. Johnson; James H. Noyes; Christen L. Williams; Brian L. Dick; Olin E. Rhodes; Rosemary J. Stussy; R. Terry Bowyer
2013-01-01
Our objective was to examine effects of groups of mixed numbers and ages of male North American elk Cervus elaphus on the reproductive performance of females. We conducted research at the Starkey Experimental Forest and Range in northeastern Oregon, USA, during 1993-2000. Each spring in late March, we released 40 female elk, eight yearling (9-month...
John G. Kie; Alan A. Ager; R. Terry. Bowyer
2005-01-01
We examined movements of North American elk (Cervus elaphus) in northeastern Oregon, USA. Movement vectors at 449 locations over a 7762 ha area were calculated based on 16,724 sequential observations of 94 female elk-year combinations during spring (15 April-14 May) 1993, 1995, 1996. We calculated movement vectors at the start of morning and...
ERIC Educational Resources Information Center
Ersöz, Gözde; Eklund, Robert C.
2017-01-01
Objective: The purpose of this study was to examine behavioral regulations and dispositional flow in exercise among university students in terms of gender and stage of change. Participants: Data were collected from American college students (N = 257; M[subscript age] ± SD = 23.02 ± 4.05) in Spring 2013. Methods: Behavioral regulations and…
Tolerance of Planted Hardwoods to Spring Flooding
James B. Baker
1977-01-01
Cuttings of eastern cottonwood (Populus deltoides) and seedlings of sweetgum (Liquidambar styraciflua), water tupelo (Nyssa aquatica), American sycamore (Platanus occidentalis), and green ash (Fraxinus pennsylvanica) were planted on a slackwater clay (Vertic Haplaquept) in...
ERIC Educational Resources Information Center
Lasch, Christopher
1973-01-01
Reviews a book by Christopher Jencks et al., examining a number of statistical correlations between income and schooling; and also books by Katz, Spring, and Greer respectively, examining the historical development of the American public school. (JM)
Survival of young American alligators on a Florida lake
Woodward, A.R.; Hines, T.C.; Abercrombie, C.L.; Nichols, J.D.
1987-01-01
A capture-recapture study was conducted on Orange Lake, Florida, from 1979 through 1984 to estimate survival rates of young in an American alligator (Alligator mississippiensis) populations. Hatchlings remained together in sibling groups (pods) for at least their 1st year and then began to disperse during their 2nd spring and summer. Mortality through mid-November of their 1st year was negligible. Jolly-Seber (JS) survival estimates of hatchlings for 6 and 12 months were 76 and 41%, respectively. The 2-year JS estimate for the 1980 cohort was 8%. Minimum-Known-Alive (MKA) survival values were 72 and 46% of JS estimates for 6 months and 1 year of age. Survival during the 2nd 6 months of life (spring-summer) tended to be lower than survival during the 1st 6 months (fall-winter).
Xie, Hongling; Dawes, Molly; Wurster, Tabitha J; Shi, Bing
2013-01-01
The transition to middle school often presents behavioral and academic challenges to youths. Boys of color (i.e., African American and Hispanic in this study) may be especially vulnerable. In this study, peer nominations of aggressive and academic behaviors as well as youths' perceptions of how these behaviors were related to popularity in peer networks were obtained from the spring semester of fifth grade through the spring semester of seventh grade, with the transition occurring as the students entered the sixth grade. The sample included 188 boys (71 Caucasian, 90 African American, and 27 Hispanic) from an urban school district in the northeastern United States. Trajectory analyses showed that African American boys scored lower in studentship and higher in rule-breaking and aggressive (both physical and social) behaviors prior to the transition, and such differences among ethnic groups were largely maintained during the transition. Hispanic boys displayed decreases in their studentship during the transition. African American boys' perception of how studentship affects popularity was more positive than other boys prior to the transition, but it decreased during the transition. African American boys also endorsed rule breaking and physical and social aggression more positively for popularity prior to the transition, whereas Caucasian and Hispanic boys' endorsement increased during the transition and eventually caught up with those of African American boys in seventh grade. A positive within-individual association was found between youths' popularity perception and their behavior for studentship, rule breaking, and physical aggression, which did not differ by ethnicity. © 2013 American Orthopsychiatric Association.
Mechanisms of Robust Future Spring Drying in the Southwest U.S. in CMIP5 Models
NASA Astrophysics Data System (ADS)
Ting, M.; Seager, R.; Li, C.; Liu, H.
2017-12-01
The net surface water budget, precipitation minus evaporation (P-E), shows a clear seasonal cycle in the American Southwest with net gain of surface water (positive P-E) in the cold half of the year (October to March) and net loss of water (negative P-E) in the warmer half (April - September), with June and July being the driest time of the year. There is a significant shift of the summer drying toward earlier in the year under CO2 warming scenario, resulting in substantial spring drying (MAM) of the American Southwest, from the near-term future (2021 - 2040) to the end of the current Century with gradually increasing magnitude. While the spring drying has been identified in previous studies, its mechanism has not been fully addressed. Using moisture budget analysis, we found that the drying is mainly due to decreased mean moisture convergence, partially compensated by the increase in transient eddy moisture flux convergence. The decreased mean moisture convergence is further separated into those due to changes in circulation (dynamic changes) and changes in atmospheric moisture content (thermodynamic changes). The drying is found to be dominated by the thermodynamic driven changes in column averaged moisture convergence, due mainly to increased dry zonal advection caused by the climatological land-ocean thermal contrast, rather than by the well-known "dry gets drier" mechanism. Furthermore, the enhanced dry advection in the warming climate is dominated by the robust zonal mean atmospheric warming, thus the spring drying in Southwest US is very robust. We also discuss reasons this future drying is particularly strong in the spring as compared to the other seasons.
Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments.
Al-Hadlaq, Solaiman M S; Aljarbou, Fahad A; AlThumairy, Riyadh I
2010-02-01
This study was conducted to investigate cyclic flexural fatigue resistance of GT series X rotary files made from the newly developed M-wire nickel-titanium alloy compared with GT and Profile nickel-titanium files made from a conventional nickel-titanium alloy. Fifteen files, size 30/0.04, of each type were used to evaluate the cyclic flexural fatigue resistance. A simple device was specifically constructed to measure the time each file type required to fail under cyclic flexural fatigue testing. The results of this experiment indicated that the GT series X files had superior cyclic flexural fatigue resistance than the other 2 file types made from a conventional nickel-titanium alloy (P = .004). On the other hand, the difference between the Profile and the GT files was not statistically significant. The findings of this study suggest that size 30/0.04 nickel-titanium rotary files made from the newly developed M-wire alloy have better cyclic flexural fatigue resistance than files of similar design and size made from the conventional nickel-titanium alloy. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Sculpture, general view looking to the seated lions, probably from ...
Sculpture, general view looking to the seated lions, probably from the American Bungalow - National Park Seminary, Bounded by Capitol Beltway (I-495), Linden Lane, Woodstove Avenue, & Smith Drive, Silver Spring, Montgomery County, MD
The Science of Addiction: Drugs, Brains, and Behavior
... Issue Past Issues The Science of Addiction: Drugs, Brains, and Behavior Past Issues / Spring 2007 Table of ... Americans understand addiction as a chronic but treatable brain disease. The eye-opening documentary, Addiction , first aired ...
NASA Astrophysics Data System (ADS)
Ha, Jeong Won; Seong, Baek Seok; Jeong, Hi Won; Choi, Yoon Suk; Kang, Namhyun
2015-02-01
Inconel X-750 is a Ni-based precipitation-hardened superalloy typically used in springs designed for high-temperature applications such as the hold-down springs in nuclear power plants. γ‧ is a major precipitate in X-750 alloys which affects the strength, creep resistance, and stress relaxation properties of the spring. In this study, a solution-treated X-750 wire coiled into a spring was used that was aged at various temperatures and submitted to stress relaxation tests with and without loading. Small angle neutron scattering was employed to quantify the size and volume fraction of γ‧ phase in the springs as a function of the aging temperature and the application of a load during stress relaxation. The volume fraction of γ‧ precipitates increased in the specimen aged at 732 °C following stress relaxation at 500 °C for 300 h. However, the mean size of the precipitates in the samples was not affected by stress relaxation. The specimen aged at the lower temperature (620 °C) contained a smaller γ‧ volume fraction and gained a smaller fraction of γ‧ during stress relaxation compared with the sample aged at the higher temperature (732 °C). The smaller increase in the γ‧ volume fraction for the sample aged at 620 °C was associated with a larger increase in the M23C6 secondary carbide content during relaxation. The Cr depletion zone around the secondary carbides raises the solubility of γ‧ thereby decreasing the volume fraction of γ‧ precipitates in Inconel X-750. In terms of stress relaxation, a larger increase in the γ‧ volume fraction was measured with loading rather than without. This is probably associated with the dislocation accumulation generated under loading that facilitate the nucleation and growth of heterogeneous γ‧ phase due to enhanced diffusion.
NASA Astrophysics Data System (ADS)
Koizumi, Yoshiko; Shimoyama, Manabu; Oyama, Koh-Ichiro; Murayama, Yasuhiro; Tsuda, Toshitaka; Nakamura, Takuji
2004-07-01
The foil chaff technique has been used on microrockets such as "Viper" for a long time to measure neutral winds with high altitude resolution in the mesosphere and lower thermosphere. We have developed two new foil chaff storage and ejection systems for muti-instrumented sounding rockets. The first system uses a spring loaded split cylinder which holds the foil chaff, housed in an outer cylinder. The shaft of the split cylinder is kept in place by a lock plate and a stainless steel wire. The split cylinder is ejected by cutting the wire. The second system is of differential pressure type. The cap of an airtight cylinder has a shaft and a sponge piece for sweeping out the foil chaff. The cylinder is sealed at ground level and at the desired height of release, the cap comes out due to differential pressure and brings out the foil chaff. Both these systems were successfully tested on a Japanese sounding rocket in January 2000, releasing about 20 000 pieces of foil chaff during the rocket's descent. Neutral winds were measured in the height range of 85.5-95.0 km with a height resolution of 300 m.
Dagdeviren, Omur E.; Schwarz, Udo D.
2017-03-20
Quartz tuning forks that have a probe tip attached to the end of one of its prongs while the other prong is arrested to a holder (“qPlus” configuration) have gained considerable popularity in recent years for high-resolution atomic force microscopy imaging. The small size of the tuning forks and the complexity of the sensor architecture, however, often impede predictions on how variations in the execution of the individual assembly steps affect the performance of the completed sensor. Extending an earlier study that provided numerical analysis of qPlus-style setups without tips, this work quantifies the influence of tip attachment on themore » operational characteristics of the sensor. The results using finite element modeling show in particular that for setups that include a metallic tip that is connected via a separate wire to enable the simultaneous collection of local forces and tunneling currents, the exact realization of this wire connection has a major effect on sensor properties such as spring constant, quality factor, resonance frequency, and its deviation from an ideal vertical oscillation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dagdeviren, Omur E.; Schwarz, Udo D.
Quartz tuning forks that have a probe tip attached to the end of one of its prongs while the other prong is arrested to a holder (“qPlus” configuration) have gained considerable popularity in recent years for high-resolution atomic force microscopy imaging. The small size of the tuning forks and the complexity of the sensor architecture, however, often impede predictions on how variations in the execution of the individual assembly steps affect the performance of the completed sensor. Extending an earlier study that provided numerical analysis of qPlus-style setups without tips, this work quantifies the influence of tip attachment on themore » operational characteristics of the sensor. The results using finite element modeling show in particular that for setups that include a metallic tip that is connected via a separate wire to enable the simultaneous collection of local forces and tunneling currents, the exact realization of this wire connection has a major effect on sensor properties such as spring constant, quality factor, resonance frequency, and its deviation from an ideal vertical oscillation.« less
ERIC Educational Resources Information Center
TRAINOR, LOIS M.; AND OTHERS
THE SUMMER PROGRAM IS PART OF A PROGRAM IN WHICH SECOND-GRADE GIFTED STUDENTS ARE GIVEN INSTRUCTION IN BASIC THIRD-GRADE SKILLS IN LANGUAGE AND ARITHMETIC DURING THE SPRING SEMESTER. THE SUMMER SESSION PROVIDES FOR IMPROVEMENT IN THESE SKILLS ON AN INDIVIDUAL BASIS AND FOR ENRICHMENT IN SOCIAL STUDIES. THE UNIT ON THE AMERICAN INDIAN DESCRIBED IS…
ERIC Educational Resources Information Center
Foster, Karen
2015-01-01
Millions of children around the world are out of school due to conflict, poverty, lack of education systems and infrastructure, and other issues. Educating children living in difficult contexts is the best way to empower them with the knowledge and competencies to rise to their full potential despite the challenges they face. Dedicated and…
ERIC Educational Resources Information Center
Wu, Hui
2007-01-01
By reflecting on Japanese internment camps executed by the U.S. government in World War II, this article examines camp schools' curricula and writing assignments and an English teacher's response to student essays to show how racially profiled students and their Caucasian teacher negotiated the political meanings of civil rights and freedom.…
ERIC Educational Resources Information Center
Zimmerman, Paul
Focusing on the forcible relocation of West Coast Japanese-American citizens during World War II, the unit poses the question: Can democratic ideals and processes survive the conditions of total war? Some aspects of this episode considered are: public and official reactions to the Pearl Harbor attack; racial antipathies underlying the decision for…
Andrade Gomes, Nascimento Leonard Euller; Melo, Pithon Matheus; Lacerda, Santos Rogério; D'Albuquerque, Medeiros Paulo Jose
2012-03-01
The aim of this study was to evaluate the tensile strength of crimpable hooks used for arch stabilization in orthognatic surgery. Ninety stainless steel wire (0.019" × 0.026") segments, each measuring 6 cm long, were used and attached to crimpable hooks of different commercial brands. Six groups were formed (n = 10) denominated as follows: control, in which the wire segments were perpendicularly welded by spot welding machine; and the hooks groups M (Morelli), MS (Morelli with weld), TP (TP Ortho), TPS (TP with weld), TPTg (TP-tungsten), TPTgS (TP-tungsten with weld), AO (American Orthodontics), and AOS (American Orthodontics with weld). The test specimen topography was evaluated by scanning electron microscopy before and after the tensile strength tests. After obtaining the results, the analysis of variance and Kruskal-Wallis multiple-comparison tests were applied. Compared with the control group, the AOS ball hooks and those from TPS required a greater amount of force to be displaced along the rectangular arch. The hooks in group M were significantly easier to displace, followed by those from AO. The best ball hooks for clinical application are those from AOS and TPS. Copyright © 2012 Elsevier Inc. All rights reserved.
Low-Cost Intra-Articular Distraction Technique Using Kirschner Wires and a Toothed Lamina Spreader.
Shymon, Stephen Joseph; Harris, Thomas Gregory
We describe a low-cost (instrument cost) technique for joint distraction using 2 Kirschner wires and a toothed lamina spreader in lieu of a Hintermann distractor. The described technique allows for temporary intra-articular distraction and visualization and preservation of the articular surface with extra-articular instrumentation. The technique can also allow for closed reduction and percutaneous treatment in cases of soft tissue compromise. Additionally, the technique uses common orthopedic surgical instruments, leading to a minimal learning curve for novice surgeons. We have found this distraction technique to be most effective for intra-articular preparation of hindfoot and midfoot arthrodeses and for navicular fracture reduction. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Bock, Jens Johannes; Fraenzel, Wolfgang; Bailly, Jacqueline; Gernhardt, Christian Ralf; Fuhrmann, Robert Andreas Werner
2008-08-01
The aim of this study was to compare the mechanical strength and microhardness of joints made by conventional brazing and tungsten inert gas (TIG) and laser welding. A standardized end-to-end joint configuration of the orthodontic wire material in spring hard quality was used. The joints were made using five different methods: brazing (soldering > 450 degrees C) with universal silver solder, two TIG, and two laser welders. Laser parameters and welding conditions were used according to the manufacturers' guidance. The tensile strengths were measured with a universal testing machine (Zwick 005). The microhardness measurements were carried out with a hardness tester (Zwick 3202). Data were analysed using one-way analysis of variance and Bonferroni's post hoc correction (P < 0.05). In all cases, brazing joints ruptured at low levels of tensile strength (198 +/- 146 MPa). Significant differences (P < 0.001) between brazing and TIG or laser welding were found. The highest means were observed for TIG welding (699-754 MPa). Laser welding showed a significantly lower mean tensile strength (369-520 MPa) compared with TIG welding. Significant differences (P < 0.001) were found between the original orthodontic wire and the mean microhardness at the centre of the welded area. The mean microhardness differed significantly between brazing (1.99 GPa), TIG (2.22-2.39 GPa) and laser welding (2.21-2.68 GPa). For orthodontic purposes, laser and TIG welding are solder-free alternatives to joining metal. TIG welding with a lower investment cost is comparable with laser welding. However, while expensive, the laser technique is a sophisticated and simple method.
Bock, Jens Johannes; Bailly, Jacqueline; Gernhardt, Christian Ralf; Fuhrmann, Robert Andreas Werner
2008-01-01
The aim of this study was to compare the mechanical strength of different joints made by conventional brazing, TIG and laser welding with and without filling material. Five standardized joining configurations of orthodontic wire in spring hard quality were used: round, cross, 3 mm length, 9 mm length and 7 mm to orthodontic band. The joints were made by five different methods: brazing, tungsten inert gas (TIG) and laser welding with and without filling material. For the original orthodontic wire and for each kind of joint configuration or connecting method 10 specimens were carefully produced, totalizing 240. The fracture strengths were measured with a universal testing machine (Zwick 005). Data were analyzed by ANOVA (p=0.05) and Bonferroni post hoc test (p=0.05). In all cases, brazing joints were ruptured on a low level of fracture strength (186-407 N). Significant differences between brazing and TIG or laser welding (p<0.05, Bonferroni post hoc test) were found in each joint configuration. The highest fracture strength means were observed for laser welding with filling material and 3 mm joint length (998 N). Using filling materials, there was a clear tendency to higher mean values of fracture strength in TIG and laser welding. However, statistically significant differences were found only in the 9-mm long joints (p<0.05, Bonferroni post hoc test). In conclusion, the fracture strength of welded joints was positively influenced by the additional use of filling material. TIG welding was comparable to laser welding except for the impossibility of joining orthodontic wire with orthodontic band.
Bock, Jens Johannes; Bailly, Jacqueline; Gernhardt, Christian Ralf; Fuhrmann, Robert Andreas Werner
2008-01-01
The aim of this study was to compare the mechanical strength of different joints made by conventional brazing, TIG and laser welding with and without filling material. Five standardized joining configurations of orthodontic wire in spring hard quality were used: round, cross, 3 mm length, 9 mm length and 7 mm to orthodontic band. The joints were made by five different methods: brazing, tungsten inert gas (TIG) and laser welding with and without filling material. For the original orthodontic wire and for each kind of joint configuration or connecting method 10 specimens were carefully produced, totalizing 240. The fracture strengths were measured with a universal testing machine (Zwick 005). Data were analyzed by ANOVA (p=0.05) and Bonferroni post hoc test (p=0.05). In all cases, brazing joints were ruptured on a low level of fracture strength (186-407 N). Significant differences between brazing and TIG or laser welding (p<0.05, Bonferroni post hoc test) were found in each joint configuration. The highest fracture strength means were observed for laser welding with filling material and 3 mm joint length (998 N). Using filling materials, there was a clear tendency to higher mean values of fracture strength in TIG and laser welding. However, statistically significant differences were found only in the 9-mm long joints (p<0.05, Bonferroni post hoc test). In conclusion, the fracture strength of welded joints was positively influenced by the additional use of filling material. TIG welding was comparable to laser welding except for the impossibility of joining orthodontic wire with orthodontic band. PMID:19089229
Victimization from Mental and Physical Bullying and Substance Use in Early Adolescence
Tharp-Taylor, Shannah; Haviland, Amelia; D'Amico, Elizabeth J.
2009-01-01
Logistic regression analyses were used to assess the association between victimization from mental and physical bullying and use of alcohol, cigarettes, marijuana, and inhalants among middle school students. Self-report data were analyzed from 926 ethnically diverse sixth through eighth grade students (43% white, 26% Latino, 7% Asian American/Pacific Islander, 3% African American, 14% mixed ethnic origin, and 5% “other”) ages 11 – 14 years from southern California. Substance use was collected at two time points (fall 2004 and spring 2005) during an academic year. Models were run for each substance separately. Results supported an association between victimization from bullying and substance use. Youths who experienced each type of bullying (mental or physical) separately or in combination were more likely to report use of each substance in spring 2005. This finding held after controlling for gender, grade level, ethnicity and substance use in fall 2004. PMID:19398162
2006-01-01
Assessing and understanding the health needs and capacities of college students is paramount to creating healthy campus communities. The American College Health Association-National College Health Assessment (ACHA-NCHA) is a survey instrument developed by the ACHA in 1998 to assist institutions of higher education in achieving this goal. The ACHA-NCHA contains approximately 300 questions assessing student health status and health problems, risk and protective behaviors, access to health information, impediments to academic performance, and perceived norms across a variety of content areas (eg, injury prevention; personal safety and violence; alcohol, tobacco, and other drug use; sexual health; weight, nutrition, and exercise; mental health). Twice a year, the ACHA compiles aggregate data from participating institutions in a reference group report for data comparison. Results from the Spring 2005 Reference Group (N = 54,111) are presented in this article.
2006-01-01
Assessing and understanding the health needs and capacities of college students is paramount to creating healthy campus communities. The American College Health Association-National College Health Assessment (ACHA-NCHA) is a survey instrument developed by the ACHA in 1998 to assist institutions of higher education in achieving this goal. The ACHA-NCHA contains approximately 300 questions assessing student health status and health problems, risk and protective behaviors, access to health information, impediments to academic performance, and perceived norms across a variety of content areas, including injury prevention; personal safety and violence; alcohol, tobacco, and other drug use; sexual health; weight, nutrition, and exercise; and mental health. Twice a year, the ACHA compiles aggregate data from participating institutions in a reference group report for data comparison. Results from the Spring 2004 Reference Group (N = 47,202) are presented in this article.
Turkey’s Iran Card: Energy Cooperation in American and Russian Vortex
2004-06-01
Turkey and Iran During the Cold War,” Journal of Third World Studies, Spring 1999, Vol.16, No.1, p.23. 15 imports and 4 % of total exports to Turkey...16 Michael B.Bishku, “Turkey and Iran During the Cold War,” Journal of Third World Studies, Spring 1999, Vol.16, No.1, pp.23-24. 17 Andrew Mango ...result of Ukraine’s usage of the Russian exports to Germany. Therefore, the EU has to diversify its natural gas supply to ensure European energy
Chaudhary, A.; Haack, S.K.; Duris, J.W.; Marsh, T.L.
2009-01-01
Studies of sulfidic springs have provided new insights into microbial metabolism, groundwater biogeochemistry, and geologic processes. We investigated Great Sulphur Spring on the western shore of Lake Erie and evaluated the phylogenetic affiliations of 189 bacterial and 77 archaeal 16S rRNA gene sequences from three habitats: the spring origin (11-m depth), bacterial-algal mats on the spring pond surface, and whitish filamentous materials from the spring drain. Water from the spring origin water was cold, pH 6.3, and anoxic (H2, 5.4 nM; CH4, 2.70 ??M) with concentrations of S2- (0.03 mM), SO42- (14.8 mM), Ca2+ (15.7 mM), and HCO3- (4.1 mM) similar to those in groundwater from the local aquifer. No archaeal and few bacterial sequences were >95% similar to sequences of cultivated organisms. Bacterial sequences were largely affiliated with sulfur-metabolizing or chemolithotrophic taxa in Beta-, Gamma-, Delta-, and Epsilonproteobacteria. Epsilonproteobacteria sequences similar to those obtained from other sulfidic environments and a new clade of Cyanobacteria sequences were particularly abundant (16% and 40%, respectively) in the spring origin clone library. Crenarchaeota sequences associated with archaeal-bacterial consortia in whitish filaments at a German sulfidic spring were detected only in a similar habitat at Great Sulphur Spring. This study expands the geographic distribution of many uncultured Archaea and Bacteria sequences to the Laurentian Great Lakes, indicates possible roles for epsilonproteobacteria in local aquifer chemistry and karst formation, documents new oscillatorioid Cyanobacteria lineages, and shows that uncultured, cold-adapted Crenarchaeota sequences may comprise a significant part of the microbial community of some sulfidic environments. Copyright ?? 2009, American Society for Microbiology. All Rights Reserved.
Microbial Source Tracking in Adjacent Karst Springs.
Ohad, Shoshanit; Vaizel-Ohayon, Dalit; Rom, Meir; Guttman, Joseph; Berger, Diego; Kravitz, Valeria; Pilo, Shlomo; Huberman, Zohar; Kashi, Yechezkel; Rorman, Efrat
2015-08-01
Modern man-made environments, including urban, agricultural, and industrial environments, have complex ecological interactions among themselves and with the natural surroundings. Microbial source tracking (MST) offers advanced tools to resolve the host source of fecal contamination beyond indicator monitoring. This study was intended to assess karst spring susceptibilities to different fecal sources using MST quantitative PCR (qPCR) assays targeting human, bovine, and swine markers. It involved a dual-time monitoring frame: (i) monthly throughout the calendar year and (ii) daily during a rainfall event. Data integration was taken from both monthly and daily MST profile monitoring and improved identification of spring susceptibility to host fecal contamination; three springs located in close geographic proximity revealed different MST profiles. The Giach spring showed moderate fluctuations of MST marker quantities amid wet and dry samplings, while the Zuf spring had the highest rise of the GenBac3 marker during the wet event, which was mirrored in other markers as well. The revelation of human fecal contamination during the dry season not connected to incidents of raining leachates suggests a continuous and direct exposure to septic systems. Pigpens were identified in the watersheds of Zuf, Shefa, and Giach springs and on the border of the Gaaton spring watershed. Their impact was correlated with partial detection of the Pig-2-Bac marker in Gaaton spring, which was lower than detection levels in all three of the other springs. Ruminant and swine markers were detected intermittently, and their contamination potential during the wet samplings was exposed. These results emphasized the importance of sampling design to utilize the MST approach to delineate subtleties of fecal contamination in the environment. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
ERIC Educational Resources Information Center
Radford, Alexandria Walton; Ifill, Nicole; Lew, Terry
2016-01-01
Between January and October of 2013, nearly 3 million Americans between the ages of 16 and 24 graduated from high school. By October of that year, just two-thirds had enrolled in college. This report uses recently released nationally representative High School Longitudinal Study of 2009 (HSLS:09) data from Spring 2012 to examine American high…
Executive Committee Report, April 2004
ERIC Educational Resources Information Center
Sarquis, Jerry L.; Holme, Thomas; Cooper, Melanie; White, Carol
2004-01-01
Anaheim executive committee report, April 2004 of American Chemical Society (ACS) is presented. It salutes the recipients of ACS awards at the CHED session and also covers the Spring 2004 ACS meeting abstracts, nominations for the division office and councilor's report.
Report to Congress : efforts to monitor Orbitz
DOT National Transportation Integrated Search
2002-06-27
In spring of 2001, the Department of Transportation (DOT) conducted an informal investigation of Orbitz, the online travel agency owned by five large U.S. airlines (American Airlines, Delta Air Lines, Northwest Airlines and United Air Lines). There w...
Montasser, Mona A; Keilig, Ludger; El-Bialy, Tarek; Reimann, Susanne; Jäger, Andreas; Bourauel, Christoph
2015-04-01
Our objective was to investigate the effect of archwire cross-section increases on the levels of force applied to teeth during complex malalignment correction with various archwire-bracket combinations using an experimental biomechanical setup. The study comprised 3 types of orthodontic brackets: (1) conventional ligating brackets (Victory Series [3M Unitek, Monrovia, Calif] and Mini-Taurus [Rocky Mountain Orthodontics, Denver, Colo]), (2) self-ligating brackets (SmartClip, a passive self-ligating bracket [3M Unitek]; and Time3 [Rocky Mountain Orthodontics, Denver, Colo] and SPEED [Strite Industries, Cambridge, Ontario, Canada], both active self-ligating brackets), and (3) a conventional low-friction bracket (Synergy [Rocky Mountain Orthodontics]). All brackets had a nominal 0.022-in slot size. The brackets were combined with 0.014-in and 0.016-in titanium memory wires, Therma-Ti archwires (American Orthodontics, Sheboygan, Wis). The archwires were tied to the conventional brackets with both stainless steel ligatures of size 0.010-in and elastomeric rings. A malocclusion of the maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis) was simulated. The forces recorded when using the 0.014-in archwires ranged from 1.7 ± 0.1 to 5.0 ± 0.3 N in the x-axis direction, and from 1.2 ± 0.1 to 5.5 ± 0.3 N in the z-axis direction. When we used the 0.016-in archwires, the forces ranged from 2.6 ± 0.1 to 6.0 ± 0.3 N in the x-axis direction, and from 2.0 ± 0.2 to 6.0 ± 0.4 N in the z-axis direction. Overall, the increases ranged from 16.0% to 120.0% in the x-axis and from 10.4% to 130.0% in the z-axis directions. Increasing the cross section of the wire increased the force level invariably with all brackets. Wires of size 0.014 in produced relatively high force levels, and the force level increased with 0.016-in wires. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yu, Bin; Lin, H.; Wu, Z. W.; Merryfield, W. J.
2018-03-01
The Asian-Bering-North American (ABNA) teleconnection index is constructed from the normalized 500-hPa geopotential field by excluding the Pacific-North American pattern contribution. The ABNA pattern features a zonally elongated wavetrain originating from North Asia and flowing downstream across Bering Sea and Strait towards North America. The large-scale teleconnection is a year-round phenomenon that displays strong seasonality with the peak variability in winter. North American surface temperature and temperature extremes, including warm days and nights as well as cold days and nights, are significantly controlled by this teleconnection. The ABNA pattern has an equivalent barotropic structure in the troposphere and is supported by synoptic-scale eddy forcing in the upper troposphere. Its associated sea surface temperature anomalies exhibit a horseshoe-shaped structure in the North Pacific, most prominent in winter, which is driven by atmospheric circulation anomalies. The snow cover anomalies over the West Siberian plain and Central Siberian Plateau in autumn and spring and over southern Siberia in winter may act as a forcing influence on the ABNA pattern. The snow forcing influence in winter and spring can be traced back to the preceding season, which provides a predictability source for this teleconnection and for North American temperature variability. The ABNA associated energy budget is dominated by surface longwave radiation anomalies year-round, with the temperature anomalies supported by anomalous downward longwave radiation and damped by upward longwave radiation at the surface.
Deufel, Christopher L; Mullins, John P; Zakhary, Mark J
2018-05-17
Nasobiliary high-dose-rate (HDR) brachytherapy has emerged as an effective tool to boost the radiation dose for patients with unresectable perihilar cholangiocarcinoma. This work describes a quality assurance (QA) tool for measuring the HDR afterloader's performance, including the transit dose, when the source wire travels through a tortuous nasobiliary catheter path. The nasobiliary QA device was designed to mimic the anatomical path of a nasobiliary catheter, including the nasal, stomach, duodenum, and bile duct loops. Two of these loops, the duodenum and bile duct loops, have adjustable radii of curvature, resulting in the ability to maximize stress on the source wire in transit. The device was used to measure the performance over time for the HDR afterloader and the differences between intraluminal catheter lots. An upper limit on the transit dose was also measured using radiochromic film and compared with a simple theoretical model. The QA device was capable of detecting performance variations among nasobiliary catheter lots and following radioactive source replacement. The transit dose from a nasobiliary treatment increased by up to one order of magnitude when the source wire encountered higher than normal friction. Three distinct travel speeds of the source wire were observed: 5.2, 17.4, and 54.7 cm/s. The maximum transit dose was 0.3 Gy at a radial distance of 5 mm from a 40.3 kU 192 Ir source. The source wire encounters substantially greater friction when it navigates through the nasobiliary brachytherapy catheter. A QA tool that mimics the nasal, stomach, duodenum, and bile duct loops may be used to evaluate transit dose and the afterloader's performance over time. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Coverage of Developed and Developing Nations in American Wire Services to Asia.
ERIC Educational Resources Information Center
Giffard, C. Anthony
A study was conducted to contrast the news coverage of developed and developing nations, and of the United States specifically, as transmitted to Asia by the Associated Press (AP) and United Press International (UPI). A total of 556 AP reports and 453 UPI reports drawn from a 6-week period were coded for more than 100 variables and 47 topics. The…
ERIC Educational Resources Information Center
Craft, John E.; Matera, Frances R.
The historic development of the cable phenomenon is traced through industry rhetoric that promised a multitude of services and "voices" in exchange for benign regulations. The current rhetoric of the "wired nation's" latest entrant into the broadband information delivery business--the telcos--also is examined in order to assess…
Henson, Mary P.; Bergstedt, Roger A.; Adams, Jean V.
2003-01-01
The ability to predict when sea lampreys (Petromyzon marinus) will metamorphose from the larval phase to the parasitic phase is essential to the operation of the sea lamprey control program. During the spring of 1994, two populations of sea lamprey larvae from two rivers were captured, measured, weighed, implanted with coded wire tags, and returned to the same sites in the streams from which they were taken. Sea lampreys were recovered in the fall, after metamorphosis would have occurred, and checked for the presence of a tag. When the spring data were compared to the fall data it was found that the minimum requirements (length ≥ 120 mm, weight ≥ 3 g, and condition factor ≥ 1.50) suggested for metamorphosis did define a pool of larvae capable of metamorphosing. However, logistic regressions that relate the probability of metamorphosis to size are necessary to predict metamorphosis in a population. The data indicated, based on cross-validation, that weight measurements alone predicted metamorphosis with greater precision than length or condition factor in both the Marengo and Amnicon rivers. Based on the Akaike Information Criterion, weight alone was a better predictor in the Amnicon River, but length and condition factor combined predicted metamorphosis better in the Marengo River. There would be no additional cost if weight alone were used instead of length. However, if length and weight were measured the gain in predictive power would not be enough to justify the additional cost.
John Day River Subbasin Fish Habitat Enhancement Project, 2005-2006 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, Russ M.; Alley, Pamela D.; Delano, Kenneth H.
2006-03-01
Work undertaken in 2005 included: (1) Four new fence projects were completed thereby protecting 7.55 miles of stream with 9.1 miles of new riparian fence (2) Fence removal 1.7 miles of barbed wire. (3) Completed three spring developments (repair work on two BLM springs on Cottonwood Creek (Dayville), 1 solar on Rock Creek/ Collins property). (4) Dredge tail leveling completed on 0.9 miles of the Middle Fork of the John Day River (5) Cut, hauled and placed 30 junipers on Indian Creek/Kuhl property for bank stability. (6) Collected and planted 1500 willow cuttings on Mountain Creek/Jones property. (7) Conducted steelheadmore » redd counts on Lake Cr./Hoover property and Cottonwood Cr./Mascall properties (8) Seeded 200 lbs of native grass seed on projects where the sites were disturbed by fence construction activities. (9) Maintenance of all active project fences (72.74 miles), watergaps (60), spring developments (30) were checked and repairs performed. (10) Since the initiation of the Fish Habitat Program in 1984 we have installed 156.06 miles of riparian fence on leased property protecting 88.34 miles of anadromous fish bearing stream. With the addition of the Restoration and Enhancement Projects from 1996-2001, where the landowner received the materials, built and maintained the project we have a total of 230.92 miles of fence protecting 144.7 miles of stream and 3285 acres of riparian habitat.« less
NASA Astrophysics Data System (ADS)
Kamps, Ray H.; Tatum, Gregg S.; Gault, Mike; Groeger, Alan W.
2009-06-01
Goodenough Spring (Texas, USA) is a large spring near the border of the American state of Texas and the Mexican state of Coahuila, discharging into the international Amistad Reservoir on the river Rio Grande (Rio Bravo). Discharge was routinely measured from 1928 until 1968 to partition the flow of the river between the two countries in accordance with water-use treaties. Samples were analyzed for water-quality parameters in 1967-1968 prior to inundation under 45 m of Amistad Reservoir in 1968. Subsequently, discharge has been estimated indirectly by the International Boundary and Water Commission (IBWC). For the first direct measurements of the spring in 37 years, velocity and cross-sectional measurements were made and water samples collected in the summer of 2005 using advanced self-contained underwater breathing apparatus (SCUBA) techniques. Spring discharge was calculated at 2.03 m3 s-1, approximately one-half of the historical mean of 3.94 m3 s-1. In situ and laboratory analyses of samples for temperature, pH, dissolved oxygen, specific conductance, alkalinity, nitrate-nitrogen, dissolved solids, chloride, sulfate, fluoride, phosphorus, calcium, sodium, potassium, magnesium, and iron showed the water quality to be very good for human consumption and crop irrigation. Measurement values are relatively unchanged from those reported 37 years prior.
NASA Technical Reports Server (NTRS)
Entzian, G.; Grasnick, K. H.; Taubenheim, J.
1989-01-01
The long term trends (least square linear regression with time) of ozone content at seven European, seven North American, three Japanese and two tropical stations during 21 years (1964 to 1984) are analyzed. In all regions negative trends are observed during the 1970s, but are partly compensated by limited periods of positive trends during the late 1960s and late 1970s. Solely the North American ozone data show negative trends in all 10 year periods. When the long term ozone trends are evaluated for each month of the year separately, a seasonal variation is revealed, which in Europe and North America has largest negative trends in late winter and spring. While in Europe the negative trends in winter/spring are partly compensated by positive trends in summer, in North America the summer values reach only zero, retaining the significant negative trend in annual mean values. In contrast to the antarctic ozone hole, the spring reduction of ozone in Europe and in North America is associated with stratospheric temperatures increasing in the analyzed period and therefore is consistent with the major natural ozone production and loss processes.
Delling, Bo; Palm, Stefan; Palkopoulou, Eleftheria; Prestegaard, Tore
2014-01-01
Presence of sympatric populations may reflect local diversification or secondary contact of already distinct forms. The Baltic cisco (Coregonus albula) normally spawns in late autumn, but in a few lakes in Northern Europe sympatric autumn and spring- or winter-spawners have been described. So far, the evolutionary relationships and taxonomic status of these main life history forms have remained largely unclear. With microsatellites and mtDNA sequences, we analyzed extant and extinct spring- and autumn-spawners from a total of 23 Swedish localities, including sympatric populations. Published sequences from Baltic ciscoes in Germany and Finland, and Coregonus sardinella from North America were also included together with novel mtDNA sequences from Siberian C. sardinella. A clear genetic structure within Sweden was found that included two population assemblages markedly differentiated at microsatellites and apparently fixed for mtDNA haplotypes from two distinct clades. All sympatric Swedish populations belonged to the same assemblage, suggesting parallel evolution of spring-spawning rather than secondary contact. The pattern observed further suggests that postglacial immigration to Northern Europe occurred from at least two different refugia. Previous results showing that mtDNA in Baltic cisco is paraphyletic with respect to North American C. sardinella were confirmed. However, the inclusion of Siberian C. sardinella revealed a more complicated pattern, as these novel haplotypes were found within one of the two main C. albula clades and were clearly distinct from those in North American C. sardinella. The evolutionary history of Northern Hemisphere ciscoes thus seems to be more complex than previously recognized. PMID:25540695
Delling, Bo; Palm, Stefan; Palkopoulou, Eleftheria; Prestegaard, Tore
2014-11-01
Presence of sympatric populations may reflect local diversification or secondary contact of already distinct forms. The Baltic cisco (Coregonus albula) normally spawns in late autumn, but in a few lakes in Northern Europe sympatric autumn and spring- or winter-spawners have been described. So far, the evolutionary relationships and taxonomic status of these main life history forms have remained largely unclear. With microsatellites and mtDNA sequences, we analyzed extant and extinct spring- and autumn-spawners from a total of 23 Swedish localities, including sympatric populations. Published sequences from Baltic ciscoes in Germany and Finland, and Coregonus sardinella from North America were also included together with novel mtDNA sequences from Siberian C. sardinella. A clear genetic structure within Sweden was found that included two population assemblages markedly differentiated at microsatellites and apparently fixed for mtDNA haplotypes from two distinct clades. All sympatric Swedish populations belonged to the same assemblage, suggesting parallel evolution of spring-spawning rather than secondary contact. The pattern observed further suggests that postglacial immigration to Northern Europe occurred from at least two different refugia. Previous results showing that mtDNA in Baltic cisco is paraphyletic with respect to North American C. sardinella were confirmed. However, the inclusion of Siberian C. sardinella revealed a more complicated pattern, as these novel haplotypes were found within one of the two main C. albula clades and were clearly distinct from those in North American C. sardinella. The evolutionary history of Northern Hemisphere ciscoes thus seems to be more complex than previously recognized.
Proceedings of the Ninth American Woodcock Symposium
McAuley, Daniel G.; Bruggink, John G.; Sepik, Greg F.
2000-01-01
The Ninth Woodcock Symposium was held January 26-28, 1997 in Baton Rough, Louisiana. Contents include: American Woodcock Management, Past, Present, and Future; Current Population Status and Likely Future Trends for American Woodcock; American Woodcock Use of Reclaimed Surface Mines in West Virginia; Food Habits and Preferences of American Woodcock in East Texas Pine Plantations; Activities and Preliminary Results of Research on Woodcock (Scolopax rusticola) in Europe; Determining Multiscale Habitat and Landscape Associations for American Woodcock in Pennsylvania; Habitat Management for Wintering American Woodcock in the Southeastern United States; Sources of Variation in Survival and Recovery Rates of American Woodcock; Survival of Female American Woodcock Breeding in Maine; Direct Recoveries From In-season Banding of American Woodcock in South-central Louisiana; Gonadal Condition of American Woodcock Harvested in Louisiana During the 1986-1988 Hunting Seasons; Weight Variation Among American Woodcock Wintering in South-central Louisiana; Factors Influencing Recruitment and Condition of American Woodcock in Minnesota; The Woodcock Trail Demonstration Area in Pennsylvania; Land-use/Land-cover Changes Along Woodcock Singing-ground Survey Routes in West Virginia; Assessing Habitat Selection in Spring by Male American Woodcock in Maine with a Geographic Information System.
Nanowire failure: long = brittle and short = ductile.
Wu, Zhaoxuan; Zhang, Yong-Wei; Jhon, Mark H; Gao, Huajian; Srolovitz, David J
2012-02-08
Experimental studies of the tensile behavior of metallic nanowires show a wide range of failure modes, ranging from ductile necking to brittle/localized shear failure-often in the same diameter wires. We performed large-scale molecular dynamics simulations of copper nanowires with a range of nanowire lengths and provide unequivocal evidence for a transition in nanowire failure mode with change in nanowire length. Short nanowires fail via a ductile mode with serrated stress-strain curves, while long wires exhibit extreme shear localization and abrupt failure. We developed a simple model for predicting the critical nanowire length for this failure mode transition and showed that it is in excellent agreement with both the simulation results and the extant experimental data. The present results provide a new paradigm for the design of nanoscale mechanical systems that demarcates graceful and catastrophic failure. © 2012 American Chemical Society
Si/InGaN core/shell hierarchical nanowire arrays and their photoelectrochemical properties.
Hwang, Yun Jeong; Wu, Cheng Hao; Hahn, Chris; Jeong, Hoon Eui; Yang, Peidong
2012-03-14
Three-dimensional hierarchical nanostructures were synthesized by the halide chemical vapor deposition of InGaN nanowires on Si wire arrays. Single phase InGaN nanowires grew vertically on the sidewalls of Si wires and acted as a high surface area photoanode for solar water splitting. Electrochemical measurements showed that the photocurrent density with hierarchical Si/InGaN nanowire arrays increased by 5 times compared to the photocurrent density with InGaN nanowire arrays grown on planar Si (1.23 V vs RHE). High-resolution transmission electron microscopy showed that InGaN nanowires are stable after 15 h of illumination. These measurements show that Si/InGaN hierarchical nanostructures are a viable high surface area electrode geometry for solar water splitting. © 2012 American Chemical Society
NASA Astrophysics Data System (ADS)
Granitzer, P.; Rumpf, K.; Hofmayer, M.; Krenn, H.; Pölt, P.; Reichmann, A.; Hofer, F.
2007-04-01
A matrix of mesoporous silicon offering an array of quasi 1-dimensional oriented pores of high aspect ratio perpendicular to the sample surface has been produced. This porous silicon (PS) skeleton is filled with Ni in a further process-step to achieve ferromagnetic metallic nanostructures within the channels. This produced silicon based nanocomposite is compatible with state-of-the-art silicon technology. Beside the vertical magnetic surface anisotropy of this Ni-filled composite the nearly monodisperse distribution of pore diameters and its regular arrangement in a quasi 2-dimensional lattice provides novel magnetic phenomena like a depression of the magnetization curve at magnetic fields beyond 2T, which can be interpreted as a field induced antiferromagnetic exchange interaction between Ni-wires which is strongly influenced by magnetostrictive stresses at the Ni/Si-interface. 2007 American Institute of Physics
Non-Lethal Weapons: A Technology Gap or Lack or Available Systems, Training, and Proper Application
2016-06-10
Ibid., 190-191. 9 Jonathan D. Moreno, “Medical Ethics and Non-Lethal Weapons ,” The American Journal of Bioethics 4, no. 4 (Fall 2004): W1...Quarterly (Spring-Summer 2001): 18-22. Moreno, Jonathan D. “Medical Ethics and Non-Lethal Weapons .” The American Journal of Bioethics 4, no. 4 (Fall...NON-LETHAL WEAPONS : A TECHNOLOGY GAP OR LACK OF AVAILABLE SYSTEMS, TRAINING, AND PROPER APPLICATION A thesis presented to
ERIC Educational Resources Information Center
Bauer, Evelyn, Ed.
Intended for teachers and other educators teaching English in the educational system of the Bureau of Indian Affairs (BIA), this compilation of the first three issues of English for American Indians includes the following articles on English as a Second Language (ESL): (1) "Language Drill and Young Children" (a teaching approach of…
ERIC Educational Resources Information Center
Lewy, Rafael, Ed.; Henry, Alberta, Ed.
Presentations from a symposium series sponsored by the Salt Lake City School District and the Utah Endowment for the Humanities in the spring of 1980 describe the family customs and ethnic traditions of Asians, Blacks, Greeks, Native Americans, Polynesians, and Hispanics. The first presentation notes the differences between Asians who have been in…
Ikeda, Yuhei; Kokai, Satoshi; Ono, Takashi
2018-01-01
Skeletal and dental discrepancies cause asymmetric malocclusions in orthodontic patients. It is difficult to achieve adequate functional occlusion and guidance in patients with congenital absence of a mandibular incisor due to the tooth-size discrepancy. Here, we describe the orthodontic treatment of a 22-year-old woman with an asymmetric Angle Class II malocclusion, mandibular deviation to the left, and 3 mandibular incisors. The anterior teeth and maxillary canines were crowded. We used an improved superelastic nickel-titanium alloy wire (Tomy International, Tokyo, Japan) to compensate for the asymmetric mandibular arch and an asymmetrically bent archwire to move the maxillary molars distally. A skeletal anchorage system provided traction for intermaxillary elastics, and extractions were not needed. We alleviated the crowding and created an ideal occlusion with proper overjet, overbite, and anterior guidance with Class I canine and molar relationships. This method of treatment with an asymmetrically bent nickel-titanium alloy wire provided proper Class I occlusion and anterior guidance despite the mandibular deviation to the left and 3 mandibular incisors, without the need for extractions. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
A proton wire and water channel revealed in the crystal structure of isatin hydrolase.
Bjerregaard-Andersen, Kaare; Sommer, Theis; Jensen, Jan K; Jochimsen, Bjarne; Etzerodt, Michael; Morth, J Preben
2014-08-01
The high resolution crystal structures of isatin hydrolase from Labrenzia aggregata in the apo and the product state are described. These are the first structures of a functionally characterized metal-dependent hydrolase of this fold. Isatin hydrolase converts isatin to isatinate and belongs to a novel family of metalloenzymes that include the bacterial kynurenine formamidase. The product state, mimicked by bound thioisatinate, reveals a water molecule that bridges the thioisatinate to a proton wire in an adjacent water channel and thus allows the proton released by the reaction to escape only when the product is formed. The functional proton wire present in isatin hydrolase isoform b represents a unique catalytic feature common to all hydrolases is here trapped and visualized for the first time. The local molecular environment required to coordinate thioisatinate allows stronger and more confident identification of orthologous genes encoding isatin hydrolases within the prokaryotic kingdom. The isatin hydrolase orthologues found in human gut bacteria raise the question as to whether the indole-3-acetic acid degradation pathway is present in human gut flora. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Anteau, M.J.; Afton, A.D.
2009-01-01
The “spring condition” hypothesis (SCH) states that nutrition during spring migration affects survival, reproductive success, and, ultimately, population size of migratory birds. The North American population of Lesser Scaup (Aythya affinis) has experienced a marked decline, apparently because of poor recruitment. An important prediction of the SCH is that female Lesser Scaup have low lipid reserves during spring migration. We previously reported that lipid reserves and body mass of females collected on migratory stopover areas in northwestern Minnesota in springs 2000–2001 were lower than those on the same areas in the 1980s and markedly lower than those collected at Pool 19 of the Mississippi River in 2000–2001, an important preceding stopover area. However, it was unclear whether these findings represented a site-specific result or a landscape-scale phenomenon. Accordingly, we examined lipid and body mass of 641 female Lesser Scaup migrating across seven eco-physiographic regions of Iowa, Minnesota, and North Dakota during springs 2003–2005. We found that lipids and body mass of females throughout the Upper Midwest were similar to or less than the low values documented in northwestern Minnesota in springs 2000–2001 and markedly lower than those of females at Pool 19 in springs 2000–2001. Accordingly, our results are consistent with a prediction of the SCH, because lipid and body mass of females are low throughout this large landscape, lower than at an important preceding stopover area, and lower than all historical values. Finally, our results suggest the potential for cross-seasonal influences of nutrition on recruitment and that a stronger management focus on spring migration habitats may be necessary for conservation and recovery of declining migratory birds, especially Lesser Scaup.
Snap-through twinkling energy generation through frequency up-conversion
NASA Astrophysics Data System (ADS)
Panigrahi, Smruti R.; Bernard, Brian P.; Feeny, Brian F.; Mann, Brian P.; Diaz, Alejandro R.
2017-07-01
A novel experimental energy harvester is investigated for its energy harvesting capability by frequency up-conversion using snap-through structures. In particular, a single-degree-of-freedom (SDOF) experimental energy harvester model is built using a snap-through nonlinear element. The snap-through dynamics is facilitated by the experimental setup of a twinkling energy generator (TEG) consisting of linear springs and attracting cylindrical bar magnets. A cylindrical coil of enamel-coated magnet wire is used as the energy generator. The governing equations are formulated mathematically and solved numerically for a direct comparison with the experimental results. The experimental TEG and the numerical simulation results show 25-fold frequency up-conversion and the power harvesting capacity of the SDOF TEG.
Passmore, Brandon; Cole, Zach; Whitaker, Bret; Barkley, Adam; McNutt, Ty; Lostetter, Alexander
2016-08-02
A multichip power module directly connecting the busboard to a printed-circuit board that is attached to the power substrate enabling extremely low loop inductance for extreme environments such as high temperature operation. Wire bond interconnections are taught from the power die directly to the busboard further enabling enable low parasitic interconnections. Integration of on-board high frequency bus capacitors provide extremely low loop inductance. An extreme environment gate driver board allows close physical proximity of gate driver and power stage to reduce overall volume and reduce impedance in the control circuit. Parallel spring-loaded pin gate driver PCB connections allows a reliable and reworkable power module to gate driver interconnections.
High Temperature, Wireless Seismometer Sensor for Venus
NASA Technical Reports Server (NTRS)
Ponchak, George E.; Scardelletti, Maximilian C.; Taylor, Brandt; Beard, Steve; Meredith, Roger D.; Beheim, Glenn M.; Hunter Gary W.; Kiefer, Walter S.
2012-01-01
Space agency mission plans state the need to measure the seismic activity on Venus. Because of the high temperature on Venus (462? C average surface temperature) and the difficulty in placing and wiring multiple sensors using robots, a high temperature, wireless sensor using a wide bandgap semiconductor is an attractive option. This paper presents the description and proof of concept measurements of a high temperature, wireless seismometer sensor for Venus. A variation in inductance of a coil caused by the movement of an aluminum probe held in the coil and attached to a balanced leaf-spring seismometer causes a variation of 700 Hz in the transmitted signal from the oscillator/sensor system at 426? C. This result indicates that the concept may be used on Venus.
A miniature Joule-Thomson cooler for optical detectors in space.
Derking, J H; Holland, H J; Tirolien, T; ter Brake, H J M
2012-04-01
The utilization of single-stage micromachined Joule-Thomson (JT) coolers for cooling small optical detectors is investigated. A design of a micromachined JT cold stage-detector system is made that focuses on the interface between a JT cold stage and detector, and on the wiring of the detector. Among various techniques, adhesive bonding is selected as most suitable technique for integrating the detector with the JT cold stage. Also, the optimum wiring of the detector is discussed. In this respect, it is important to minimize the heat conduction through the wiring. Therefore, each wire should be optimized in terms of acceptable impedance and thermal heat load. It is shown that, given a certain impedance, the conductive heat load of electrically bad conducting materials is about twice as high as that of electrically good conducting materials. A micromachined JT cold stage is designed and integrated with a dummy detector. The JT cold stage is operated at 100 K with nitrogen as the working fluid and at 140 K with methane. Net cooling powers of 143 mW and 117 mW are measured, respectively. Taking into account a radiative heat load of 40 mW, these measured values make the JT cold stage suitable for cooling a photon detector with a power dissipation up to 50 mW, allowing for another 27 to 53 mW heat load arising from the electrical leads. © 2012 American Institute of Physics
Women and Heart Disease: Sharing Advice from the Heart
... page please turn JavaScript on. Feature: Women and Heart Disease Sharing Advice From The Heart Past Issues / Spring 2016 Table of Contents This ... inspired you to get involved in the American Heart Association's Go Red For Women movement and Red ...
Education Industry, Spring 2008
2008-01-01
lost over $2 billion dollars in business revenue due to cultural misunderstandings and over 30% of the firms stated that a monolingual workforce...1 The American Heritage Dictionary of the English Language – Fourth Edition, Houghton Mifflin Company (2000): 569. 2 Ibid., 895. 3 The New
The author was in Portugal on a two-month Embassy Science Fellows Program [http://www.state.gov/g/oes/rls/fs/2003/17863.htm]. The U.S. State Department draws upon other federal agencies to provide scientific and technical expertise to American embassies around the world. Portugal...
Observations of emperor geese feeding at Nelson Lagoon, Alaska
Petersen, Margaret R.
1983-01-01
Estuaries along the north side of the Alaska Peninsula provide essential habitat for most of the American population of Emperor Goose (Chen canagica) during migration (Petersen and Gill 1982). Most of the population passes through Nelson Lagoon in spring and fall, with over 40,000 birds recorded there (Gill et al 1981). Little is known about the feeding activity of Emperor Geese while they are in estuaries, and the importance of estuaries as staging areas during spring and fall migration is poorly understood. Here I report observations on the feeding activity of emperor Geese at one estuary (Nelson Lagoon).
Bock, Jens J; Bailly, Jacqueline; Fuhrmann, Robert A
2009-06-01
The aim of this study was to compare the fracture load of different joints made by conventional brazing, tungston inert gas (TIG) and laser welding. Six standardized joining configurations of spring hard quality orthodontic wire were investigated: end-to-end, round, cross, 3 mm length, 9 mm length and 6.5 mm to orthodontic band. The joints were made by five different methods: brazing with universal silver solder, two TIG and two laser welding devices. The fracture loads were measured with a universal testing machine (Zwick 005). Data were analysed with the Mann-Whitney-Wilcoxon and Kruskal-Wallis tests. The significance level was set at P<0.05). In all cases brazed joints were ruptured at a low level of fracture load (186-407 N). Significant differences between brazing and TIG or laser welding (P<0.05) were found. The highest mean fracture loads were observed for laser welding (826 N). No differences between the various TIG or laser welding devices were demonstrated, although it was not possible to join an orthodontic wire to an orthodontic band using TIG welding. For orthodontic purposes laser and TIG welding are solder free alternatives. TIG welding and laser welding showed similar results. The laser technique is an expensive, but sophisticated and simple method.
Nico, Leo G.; Butt, Peter L.; Johnston, Gerald R.; Jelks, Howard L.; Kail, Matthew; Walsh, Stephen J.
2012-01-01
We report on the occurrence of South American suckermouth armored catfishes (Loricariidae) in the Suwannee River basin, southeastern USA. Over the past few years (2009-2012), loricariid catfishes have been observed at various sites in the Santa Fe River drainage, a major tributary of the Suwannee in the state of Florida. Similar to other introduced populations of Pterygoplichthys, there is high likelihood of hybridization. To date, we have captured nine specimens (270-585 mm, standard length) in the Santa Fe River drainage. One specimen taken from Poe Spring best agrees with Pterygoplichthys gibbiceps (Kner, 1854) or may be a hybrid with either P. pardalis or P. disjunctivus. The other specimens were taken from several sites in the drainage and include seven that best agree with Pterygoplichthys disjunctivus (Weber, 1991); and one a possible P. disjunctivus x P. pardalis hybrid. We observed additional individuals, either these or similar appearing loricariids, in Hornsby and Poe springs and at various sites upstream and downstream of the long (> 4 km) subterranean portion of the Santa Fe River. These specimens represent the first confirmed records of Pterygoplichthys in the Suwannee River basin. The P. gibbiceps specimen represents the first documented record of an adult or near adult of this species in open waters of North America. Pterygoplichthys disjunctivus or its hybrids (perhaps hybrid swarms) are already abundant and widespread in other parts of peninsular Florida, but the Santa Fe River represents a northern extension of the catfish in the state. Pterygoplichthys are still relatively uncommon in the Santa Fe drainage and successful reproduction not yet documented. However, in May 2012 we captured five adult catfish (two mature or maturing males and three gravid females) from a single riverine swallet pool. One male was stationed at a nest burrow (no eggs present). To survive the occasional harsh Florida winters, these South American catfish apparently use artesian springs as thermal refugia. In the Santa Fe River, eradication might be possible during cold periods when catfish congregate in spring habitats. However, should Pterygoplichthys increase in number and disperse more widely, the opportunity to eliminate them from the drainage will pass.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busack, Craig A.; Frye, Alice; Kassler, Todd
2004-05-01
Genetic work for 2003, as in previous years, was quite diverse. In chapter 1 we report on the use of DNA microsatellite markers to sex spring chinook collected at Roza. We have learned through comparison of sex determinations at Roza and then at CESRF that sexing green fish on the basis of morphology is somewhat inaccurate, and accurate sexing of fish at Roza is needed to estimate sex ratios of fish on the spawning grounds. Using DNA microsatellite markers, sexing accuracy was high, but not perfect. In chapter 2 we report on new genetic risk concepts currently being developed andmore » their implications for the YKFP spring chinook program. The impact on domestication of gene flow between the natural and hatchery spawning components is now much better understood. It is now possible to compare the risk of different hatchery programs much more quantitatively in the past. Thus, we can now make good predictions of how much less domesticating the Yakima spring chinook supplementation effort is than other programs. In chapter 3 we present the initial results of morphological comparisons of adult (1) hatchery-origin Upper Yakima spring chinook, (2) natural-origin U. Yakima spring chinook, and (3) Naches spring chinook. Canonical variate analysis allowed both sexes of the three groups to be classified correctly with over accuracy. The differences are subtle, but hatchery-origin fish appear to be someone thinner than natural-origin fish. This is consistent with observations of hatchery vs wild morphology in coho. In chapter 4 we describe the ongoing work to refine the Domestication Research/Monitoring Plan. Work for last year included analysis of the impact of HC line precocious males spawning in the wild, development of a misting incubation system for off-site incubation of Naches eggs, and refinement of some aspects of experimental design. The misting incubation system has broad applicability outside the project. The most recent version of the domestication monitoring plan is included as an appendix. In chapter 5 we present a final report on computer simulations of factorial mating designs. Using three different schemes for combining breeding values of fish, we found that full factorial mating offers a substantial increase in effective size over single-pair mating. Although full factorial mating may be too difficult logistically, but a significant proportion of the full factorial mating advantage can be obtained by using 2 x 2 partial factorials. We have developed a method that allows us to determine the relative effective size advantage of mixed partial factorial designs. In chapter 6 we report on an analysis of stock origin of smolts collected at Chandler. The 702 Chinook salmon smolts collected at the Chandler trap in 2003 were screened at 12 microsatellite DNA loci. A new Yakima basin baseline, consisting of spring chinook from the upper Yakima, Naches, and American River populations and fall chinook from the Marion Drain and lower Yakima populations, was created for these same 12 loci. DNA template problems with the tissue collections from the Naches, and American River populations prompted the omission of four loci prior to analysis. The results indicated: 80% Naches spring, 13% American River spring, 7% upper Yakima spring, and less than 1% for the two fall populations combined. The estimated stock proportions in the 2003 Chandler collection differed substantially from those for the 2002 collection. The temporal pattern of sampling in both Chandler smolt collections was not proportional to the observed outmigration in each year, suggesting that both of these estimates should be regarded with caution. Strengthening of the baseline data set will be a high priority for future work with Chandler smolts.« less
Major General Melvin Zais and Hamburger Hill
2012-12-06
Vietnamese were massing men, supplies, and equipment for a spring offensive) by employing tactics influenced by American material superiority.8 Since 1966...Timeline.” 33 Following the decision to replace 3-187 Infantry with 2-506 Infantry, the Iron Rakkasan commander, Lt. Col. Weldon F. Honeycutt
Calibrating the future highway safety manual predictive methods for Oregon state highways.
DOT National Transportation Integrated Search
2012-02-01
The Highway Safety Manual (HSM) was published by the American Association of State Highway and Transportation Officials (AASHTO) in the spring of 2010. Volume 2 (Part C) of the HSM includes safety predictive methods which can be used to quantitativel...
NAWIG News: The Quarterly Newsletter of the Native American Wind Interest Group, Spring 2008
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baranowski, R.
2008-03-01
The United States is home to more than 700 American Indian tribes and Native Alaska villages and corporations located on 96 million acres. Many of these tribes and villages have excellent wind resources that could be commercially developed to meet their electricity needs or for electricity export. The Wind Powering America program engages Native Americans in wind energy development, and as part of that effort, the NAWIG newsletter informs readers of events in the Native American/wind energy community. This issue features an interview with Steven J. Morello, director of DOE's newly formed Office of Indian Energy Policy and Programs, andmore » a feature on the newly installed Vestas V-47 turbine at Turtle Mountain Community College.« less
Schwenk, Eric S; Jaremko, Kellie M; Gupta, Rajnish K; Udani, Ankeet D; McCartney, Colin J L; Snively, Anne; Mariano, Edward R
Microblogs known as "tweets" are a rapid, effective method of information dissemination in health care. Although several medical specialties have described their Twitter conference experiences, Twitter-related data in the fields of anesthesiology and pain medicine are sparse. We therefore analyzed the Twitter content of 2 consecutive spring meetings of the American Society of Regional Anesthesia and Pain Medicine using publicly available online transcripts. We also examined the potential contribution of a targeted social media campaign on Twitter engagement during the conferences. The original Twitter meeting content was largely scientific in nature and created by meeting attendees, the majority of whom were nontrainee physicians. Physician trainees, however, represent an important and increasing minority of Twitter contributors. Physicians not in attendance predominantly contributed via retweeting original content, particularly picture-containing tweets, and thus increased reach to nonattendees. A social media campaign prior to meetings may help increase the reach of conference-related Twitter discussion.
Seasonal and daily plasma corticosterone rhythms in American toads, Bufo americanus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pancak, M.K.; Taylor, D.H.
1983-06-01
Concentrations of corticosterone were measured in the plasma of American toads, Bufo americanus, on a seasonal basis using a radioimmunoassay technique. Two populations of toads, maintained under different light conditions, were monitored to observe the effects of photoperiod on the seasonal rhythm of plasma corticosterone. Under a natural photoperiod toads demonstrated a rhythm consisting of a spring peak and a fall peak in corticosterone concentration. Toads maintained under a 12L:12D photoperiod all year round demonstrated a similar rhythm with peaks in the spring and fall. This suggests that an endogenous (circannual) rhythm of corticosterone may be playing an important rolemore » in the seasonal change of overt behavior and physiology of Bufo americanus. A daily rhythm of corticosterone was also detected in toads when blood samples were taken every 4 hr. When compared to a previously published circadian rhythm study of locomotor activity, the surge in corticosterone concentration for the day occurred at 1730 just prior to the peak in locomotor activity.« less
Patel, Pratik; Shanthraj, Ravi; Bhagyalakshmi, A; Garg, Nekta; Vallakati, Anisha
2016-01-01
To compare the levels of pentraxin 3 (PTX-3) in gingival crevicular fluid (GCF) in patients undergoing orthodontic canine retraction with active tieback and nickel titanium (NiTi) coil spring. Fifteen patients of the age group 15-25 years with first premolar extraction undergoing canine retraction were selected. One month after placement of 0.019" × 0.025" stainless steel wire, canine retraction was started with active tieback (150 g force) on upper right quadrant and NiTi coil spring (150 g force) on upper left quadrant. GCF samples were collected 1 h before commencement of canine retraction and thereafter at intervals of 1 h, 1 day, 1 week, and 2 weeks after application of force. The collected GCF was eluted from the microcapillary pipette in 100 μl phosphate-buffered saline (pH 5-7.2). The samples were analyzed for PTX-3 levels by the ELISA technique. The mean levels of PTX-3 at 1 h before canine retraction (baseline) was 1.30 ± 0.22 ng/ml and at 1 h 1.66 ± 0.33 ng/ml, 1 day 2.65 ± 0.09 ng/ml, 1 week 1.96 ± 0.15 ng/ml, and 2 weeks 1.37 ± 0.18 ng/ml in active tieback group. The mean levels of PTX-3 at 1 h before canine retraction was 1.32 ± 0.30 ng/ml, and at 1 h 1.71 ± 0.39 ng/ml, 1 day 2.78 ± 0.12 ng/ml, 1 week 2.52 ± 0.18 ng/ml, and 2 weeks 2.12 ± 0.17 ng/ml in NiTi coil spring group. A significant difference of P < 0.001 was found in PTX-3 levels in GCF during canine retraction between active tieback and NiTi coil spring at 1 day, 1 week, and 2 weeks. The results showed that PTX-3 levels increased from 1 h after application of orthodontic force and reached peak at 1 day, followed by a gradual decrease at 1 week and 2 weeks in both active tie back and NiTi coil spring groups.
Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean
2017-03-01
To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.
Ishida, Takayoshi; Ikemoto, Shigehiro; Ono, Takashi
2015-09-01
In some skeletal Class III adult patients with nasomaxillary hypoplasia, the LeFort I osteotomy provides insufficient correction. This case report describes a 20-year-old woman with a combination of nasomaxillary hypoplasia and a protrusive mandible with a congenitally missing mandibular second premolar. We performed a LeFort II osteotomy for maxillary advancement. Autotransplantation of a tooth was also performed; the donor tooth was used to replace the missing permanent tooth. To increase the chance of success, we applied light continuous force with an improved superelastic nickel-titanium alloy wire technique before extraction and after transplantation. The patient's profile and malocclusion were corrected, and the autotransplanted tooth functioned well. The postero-occlusal relationships were improved, and ideal overbite and overjet relationships were achieved. The methods used in this case represent a remarkable treatment. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
McSorley, R; Dickson, D W; de Brito, J A; Hewlett, T E; Frederick, J J
1994-06-01
The effects of 12 summer crop rotation treatments on population densities of Meloidogyne arenaria race 1 and on yields of subsequent spring vegetable crops were determined in microplots. The crop sequence was: (i) rotation crops during summer 1991 ; (ii) cover crop of rye (Secale cereale) during winter 1991-92; (iii) squash (Cucurbita pepo) during spring 1992; (iv) rotation crops during summer 1992; (v) rye during winter 1992-93; (vi) eggplant (Solanum melongena) during spring 1993. The 12 rotation treatments were castor (Ricinus communis), cotton (Gossypium hirsutum), velvetbean (Mucuna deeringiana), crotalaria (Crotalaria spectabilis), fallow, hairy indigo (Indigofera hirsuta), American jointvetch (Aeschynomene americana), sorghum-sudangrass (Sorghum bicolor x S. sudanense), soybean (Glycine max), horsebean (Canavalia ensiformis), sesame (Sesamum indicum), and peanut (Arachis hypogaea). Compared to peanut, the first eight rotation treatments resulted in lower (P = 0.05) numbers of M. arenaria juveniles on most sampling dates. Soybean, horsebean, and sesame rotations were less effective in suppressing nematodes. Yield of squash was greater (P = 0.05) following castor, cotton, velvetbean, and crotalaria than following peanut. Compared to the peanut rotation, yield of eggplant was enhanced (P = 0.10) following castor, crotalaria, hairy indigo, American jointvetch, and sorghum-sudangrass. Several of these rotation crops may provide a means for depressing M. arenaria population densities on a short-term basis to enhance yields in a subsequent susceptible vegetable crop.
Effects of tannin source and concentration from tree leaves on two species of tadpoles.
Earl, Julia E; Semlitsch, Raymond D
2015-01-01
Vegetation in and around freshwater ecosystems can affect aquatic organisms through the production of secondary compounds, which are retained in leaves after senescence and are biologically active. Tannins can be toxic to tadpoles, but the plant source of tannins and tannin concentration have been confounded in experimental designs in previous studies. To examine the effects of the concentration and source of tannins (tree species), we examined the effects of 4 factors on tadpole survival, growth, and development: tannin source (red oak [Quercus rubra], white oak [Quercus alba], or sugar maple [Acer saccharum]); tannin concentration (including a control); diet protein level; and tadpole species (American toad [Anaxyrus americanus] and spring peepers [Pseudacris crucifer]). Tannin source and concentration affected spring peeper survival, but American toads had uniformly high survival. Spring peepers had a lower survival rate in high tannin concentrations of oak leachate but a high survival rate in both concentrations of sugar maple leachate. These differences in survival did not correspond with changes in dissolved oxygen, and no effect of dietary protein level on tadpole performance was observed. The presence of plant leachate resulted in increased tadpole growth in both species, but the mechanism for this finding is unclear. The results of the present study show that tannin concentration and source are important factors for tadpole performance, adding further evidence that plant chemistry can affect aquatic organisms. © 2014 SETAC.
Laloi, G; Montarry, J; Guibert, M; Andrivon, D; Michot, D; Le May, C
2016-07-15
Ascochyta blight, caused by the necrotrophic ascomycete Didymella pinodes, is responsible for severe losses in winter and spring pea crops. Despite different climatic conditions, epidemics on winter and spring crops are due to a single population of D. pinodes, suggesting gene flow either between the two crops or from reservoir sources during the cropping season. This should lead to similar pathogenicity characteristics in isolates sampled from the two crops. However, these hypotheses have never been formally tested. We therefore sampled a total of 520 D. pinodes strains throughout a growing season from winter and spring pea plots (WP and SP, respectively) and from winter and spring trap plants (TWP and TSP). Amplified fragment length polymorphism (AFLP) markers revealed high genetic diversity within subpopulations, whereas pathogenicity tests showed that mean aggressiveness increases over the course of an epidemic. These results support the idea that alloinoculum contributes to the carryover of epidemics between winter and spring crops and that the most aggressive isolates are selected as an epidemic progresses. Ascochyta blight, caused by Didymella pinodes, is responsible for severe losses in pea crops. While previous studies have shown that ascochyta blight epidemics on winter and spring crops are due to a single population of D. pinodes, suggesting that isolates from the two crops present similar pathogenicity characteristics, that hypothesis have never been tested. Genetic analysis of subpopulations sampled throughout a growing season from winter and spring pea plots revealed high genetic diversity within subpopulations, whereas pathogenicity tests showed that mean aggressiveness increases over the course of an epidemic. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Tenuta, Mario; Gao, Xiaopeng; Flaten, Donald N; Amiro, Brian D
2016-07-01
Fall application of anhydrous ammonia in Manitoba is common but its impact on nitrous oxide (NO) emissions is not well known. A 2-yr study compared application before freeze-up in late fall to spring pre-plant application of anhydrous ammonia on nitrous oxide (NO) emissions from a clay soil in the Red River Valley, Manitoba. Spring wheat ( L.) and corn ( L.) were grown on two 4-ha fields in 2011 and 2012, respectively. Field-scale flux of NO was measured using a flux-gradient micrometeorological approach. Late fall treatment did not induce NO emissions soon after application or in winter likely because soil was frozen. Application time did alter the temporal pattern of emissions with late fall and spring pre-plant applications significantly increasing median daily NO flux at spring thaw and early crop growing season, respectively. The majority of emissions occurred in early growing season resulting in cumulative emissions for the crop year being numerically 33% less for late fall than spring pre-plant application. Poor yield in the first year with late fall treatment occurred because of weed and volunteer growth with delayed planting. Results show late fall application of anhydrous ammonia before freeze-up increased NO emissions at thaw and decreased emissions for the early growing season compared to spring pre-plant application. However, improved nitrogen availability of late fall application to crops the following year is required when planting is delayed because of excessive moisture in spring. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
12 CFR 790.2 - Central and regional office organization.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Road, Suite 5200, Austin, TX 78759-8490. V Alaska, Arizona, American Samoa, Colorado, Guam, Hawaii... management of conservatorships. The address of AMAC is 4807 Spicewood Springs Road, Suite 5100, Austin, Texas... developing and conducting research in support of NCUA programs, and for preparing reports on research...
Sustainability of the sugar and sugar-ethanol industry
USDA-ARS?s Scientific Manuscript database
Studies in agricultural sustainability require expertise in many fields, and the contents of this book reflect that. The seventeen chapters came out of a symposium presented at the Spring 2010 meeting of the American Chemical Society, and represent contributions from a wide variety of authors with e...
Chemistry without Borders: Careers, Research, and Entrepreneurship
USDA-ARS?s Scientific Manuscript database
This book is based on two symposia of the American Chemical Society (ACS): 1) “The Transnational Practice of Chemistry and Allied Sciences and Engineering: Study, Research and Careers without Borders” held at the Spring National Meeting in Denver in March 2015, and 2) “International Entrepreneurship...
New Systems to Beat Swimming Program Frustration.
ERIC Educational Resources Information Center
Simpson, Scott J.
1980-01-01
A swimming program with effective student placement has been designed in Colorado Springs. The beginner level established by the American Red Cross is further broken down to accommodate children under the age of five. Use of computer facilities will assist in accurate program enrollment/completion records. (CJ)
NASA Astrophysics Data System (ADS)
Khargotra, Rohit; Dhingra, Sunil; Chauhan, Ranchan; Singh, Tej
2018-05-01
The effective use of solar energy is hindered by the intermittent nature of its availability, limiting its use and effectiveness in domestic and industrial applications especially in water heating. In the present paper, the performance of different turbulator shapes in solar water heating collector system has been studied experimentally and comparison on the output performance has been carried out. Effects of insertion of coil-spring turbulator on heat transfer rate, mass flow rate, heat gain by the fluid etc. is studied by disturbing the flow inside the absorber tubes in a solar flat plate collector. The coil-spring used as a turbulator is placed inside the absorber tube which creates a continuous swirling flow along the tube wall. The results of the heat transfer have been compared well with the available results. The heat transfer rate in the collector has been found to be increased by 18% to 70%. Solar water heater having inserts in the flow tubes perform better than the conventional plain ones. It has been observed that heat losses are reduced consequently increasing the thermal performance to about 70% over the plain water heater under same operating conditions. The coil-spring used as a turbulator is placed inside the riser tube while the twisted tape is inserted into the wire coil to create a continuous swirling flow along the tube wall. The results of the heat transfer have been compared with the available results. Solar water heater having inserts in the flow tubes perform better than the conventional plain ones.
A scanning tunneling microscope capable of imaging specified micron-scale small samples.
Tao, Wei; Cao, Yufei; Wang, Huafeng; Wang, Kaiyou; Lu, Qingyou
2012-12-01
We present a home-built scanning tunneling microscope (STM) which allows us to precisely position the tip on any specified small sample or sample feature of micron scale. The core structure is a stand-alone soft junction mechanical loop (SJML), in which a small piezoelectric tube scanner is mounted on a sliding piece and a "U"-like soft spring strip has its one end fixed to the sliding piece and its opposite end holding the tip pointing to the sample on the scanner. Here, the tip can be precisely aligned to a specified small sample of micron scale by adjusting the position of the spring-clamped sample on the scanner in the field of view of an optical microscope. The aligned SJML can be transferred to a piezoelectric inertial motor for coarse approach, during which the U-spring is pushed towards the sample, causing the tip to approach the pre-aligned small sample. We have successfully approached a hand cut tip that was made from 0.1 mm thin Pt∕Ir wire to an isolated individual 32.5 × 32.5 μm(2) graphite flake. Good atomic resolution images and high quality tunneling current spectra for that specified tiny flake are obtained in ambient conditions with high repeatability within one month showing high and long term stability of the new STM structure. In addition, frequency spectra of the tunneling current signals do not show outstanding tip mount related resonant frequency (low frequency), which further confirms the stability of the STM structure.
A Concise History of the U.S. Army Signal Corps
1991-02-01
key information in defeating the Spanish. Signal Corps units participated in the capture of Manila and the assault on Fort San Antonio and Fort Malate ...advancing infantry’s position. Other signalmen rolled in wire while Sergeant Harry Chadwick photographed the events. The Americans took Fort Malate ...with the Mekong Delta’s monsoon-ridden soil , a poor foundation for communications equipment. Like signalmen of the past, they adapted to local
Moisture Absorption in Certain Tropical American Woods
1949-08-01
surface area was in unobstructed contact with the salt water. Similar wire mesh racks were weighted and placed on top of the specimens to keep them...Oak (Quercus alba)" Br. Guiana Honduras United States (control) II II Total absorption by 2 x 2 x 6-inch uncoated specimens. Probably sapwood ...only. /2 ~~ Probably sapwood Table 3 (Continued) Species Source Increase over 40 percent Fiddlewood (Vit ex Gaumeri) Roble Blanco (Tabebuia
Norling, Wayne; Jeske, Clinton W.; Thigpen, Tyler F.; Chadwick, Paul C.
2012-01-01
Migrating shorebird populations using approximately 2% of Louisiana and Texas Gulf Coastal rice fields were surveyed during spring migration (March–May of 1997 and 1998) using biweekly stratified random surveys conducted at 50 roadside survey points and approximately 30,000 shorebirds were observed. Shorebird counts were extrapolated and almost 1.4 million birds in 1997 and over 1.6 million birds of 31 species in 1998 were estimated to use rice field habitat for stopover sites in Louisiana and Texas. Greater than 50% of the estimated North American populations were estimated to use rice field habitats for five species, including a species of concern, Buff-breasted Sandpiper (Tryngites subruficollis) at 187%. Because of predictability of suitable rice field habitat acreage, timing of field preparation and water availability, coastal rice prairies are identified as critical spring migration stopover sites.
Gardner, W.P.; Susong, D.D.; Solomon, D.K.; Heasler, H.P.
2011-01-01
Multiple environmental tracers are used to investigate age distribution, evolution, and mixing in local- to regional-scale groundwater circulation around the Norris Geyser Basin area in Yellowstone National Park. Springs ranging in temperature from 3??C to 90??C in the Norris Geyser Basin area were sampled for stable isotopes of hydrogen and oxygen, major and minor element chemistry, dissolved chlorofluorocarbons, and tritium. Groundwater near Norris Geyser Basin is comprised of two distinct systems: a shallow, cool water system and a deep, high-temperature hydrothermal system. These two end-member systems mix to create springs with intermediate temperature and composition. Using multiple tracers from a large number of springs, it is possible constrain the distribution of possible flow paths and refine conceptual models of groundwater circulation in and around a large, complex hydrothermal system. Copyright 2011 by the American Geophysical Union.
Faber, Jakob A; Arrieta, Andres F; Studart, André R
2018-03-23
Origami enables folding of objects into a variety of shapes in arts, engineering, and biological systems. In contrast to well-known paper-folded objects, the wing of the earwig has an exquisite natural folding system that cannot be sufficiently described by current origami models. Such an unusual biological system displays incompatible folding patterns, remains open by a bistable locking mechanism during flight, and self-folds rapidly without muscular actuation. We show that these notable functionalities arise from the protein-rich joints of the earwig wing, which work as extensional and rotational springs between facets. Inspired by this biological wing, we establish a spring origami model that broadens the folding design space of traditional origami and allows for the fabrication of precisely tunable, four-dimensional-printed objects with programmable bioinspired morphing functionalities. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
In-vivo force decay of nickel-titanium closed-coil springs.
Cox, Crystal; Nguyen, Tung; Koroluk, Lorne; Ko, Ching-Chang
2014-04-01
Nickel-titanium closed-coil springs are purported to deliver constant forces over extended ranges of activation and working times. In-vivo studies supporting this claim are limited. The objective of this study was to evaluate changes in force-decay properties of nickel-titanium closed-coil springs after clinical use. Pseudoelastic force-deflection curves for 30 nickel-titanium coil springs (used intraorally) and 15 matched laboratory control springs (simulated intraoral conditions: artificial saliva, 37°C) were tested before and after retrieval via dynamic mechanical analysis and a testing machine, respectively, to evaluate the amounts of force-loss and hysteresis change after 4, 8, or 12 weeks of working time (n = 10 per group). The effects of the oral environment and clinical use on force properties were evaluated by comparing in-vivo and in-vitro data. The springs studied showed a statistically significant decrease in force (approximately 12%) after 4 weeks of clinical use (P <0.01), with a further significant decrease (approximately 7%) from 4 to 8 weeks (P = 0.03), and force levels appearing to remain steady thereafter. Clinical space closure at an average rate of 0.91 mm per month was still observed despite this decrease in force. In-vivo and in-vitro force-loss data were not statistically different. Nickel-titanium closed-coil springs do not deliver constant forces when used intraorally, but they still allow for space-closure rates of approximately 1 mm per month. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Harper, David; Farag, Aida
2017-01-01
We evaluated the thermal regime and relative abundance of native and nonnative fish and invertebrates within Kelly Warm Spring and Savage Ditch, Grand Teton National Park, Wyoming. Water temperatures within the system remained relatively warm year-round with mean temperatures >20 °C near the spring source and >5 °C approximately 2 km downstream of the source. A total of 7 nonnative species were collected: Convict/Zebra Cichlid (Cichlasoma nigrofasciatum), Green Swordtail (Xiphophorus hellerii), Tadpole Madtom (Noturus gyrinus), Guppy (Poecilia reticulata), Goldfish (Carassius auratus), red-rimmed melania snail (Melanoides tuberculata), and American bullfrog tadpoles (Lithobates catesbeianus). Nonnative fish (Zebra Cichlids and Green Swordtails), red-rimmed melania snails, and bullfrog tadpoles dominated the upper 2 km of the system. Abundance estimates of the Zebra Cichlid exceeded 12,000 fish/km immediately downstream of the spring source. Relative abundance of native species increased movingdownstream as water temperatures attenuated with distance from the thermally warmed spring source; however, nonnative species were captured 4 km downstream from the spring. Fish diseases were prevalent in both native and nonnative fish from the Kelly Warm Spring pond. Clinostomum marginatum, a trematode parasite, was found in native species samples, and the tapeworm Diphyllobothrium dendriticum was present in samples from nonnative species. Diphyllobothrium dendriticum is rare in Wyoming. Salmonella spp. were also found in some samples of nonnative species. These bacteria are associated with aquarium fish and aquaculture and are generally not found in the wild.
Walsh, S.J.; Haney, D.C.; Timmerman, C.M.
1997-01-01
Evolutionary theory predicts that some aquatic organisms may adapt by directional selection to limiting physical environmental conditions, yet empirical data are conflicting. We sought to test the assumption that sculpins (family Cottidae) inhabiting thermally stable springs of the southeastern United States differ in temperature tolerance and metabolism from populations inhabiting more thermally labile stream habitats. Spring populations of pygmy sculpins (Coitus pygmaeus) and Ozark sculpins (C. hypselurus) differed interspecifically in thermal tolerance from populations of stream-dwelling mottled (C. bairdi) and Tallapoosa sculpins (C. tallapoosae), and both stream and spring populations of banded sculpins (C. carolinae). No intra- or interspecific differences in thermal tolerance were found among populations of C. bairdi, C. tallapoosae, or C. carolinae. Coitus pygmaeus acclimated to 15??C differed intraspecifically in routine metabolism from fish acclimated to 20?? and 25??C. Cottus pygmaeus and stream-dwelling C. bairdi and C. carolinae acclimated to temperatures of 20?? and 25??C showed no interspecific differences in routine metabolism. Our results suggest that some spring-adapted populations or species may be more stenothermal than stream-dwelling congeners, but a greater understanding of the interactions of other physical and biological factors is required to better explain micro- and macrohabitat distributions of eastern North American sculpins.
Ault, Toby R.; Schwartz, Mark D.; Zurita-Milla, Raul; Weltzin, Jake F.; Betancourt, Julio L.
2015-01-01
Climate change is expected to modify the timing of seasonal transitions this century, impacting wildlife migrations, ecosystem function, and agricultural activity. Tracking seasonal transitions in a consistent manner across space and through time requires indices that can be used for monitoring and managing biophysical and ecological systems during the coming decades. Here a new gridded dataset of spring indices is described and used to understand interannual, decadal, and secular trends across the coterminous United States. This dataset is derived from daily interpolated meteorological data, and the results are compared with historical station data to ensure the trends and variations are robust. Regional trends in the first leaf index range from 20.8 to 21.6 days decade21, while first bloom index trends are between20.4 and 21.2 for most regions. However, these trends are modulated by interannual to multidecadal variations, which are substantial throughout the regions considered here. These findings emphasize the important role large-scale climate modes of variability play in modulating spring onset on interannual to multidecadal time scales. Finally, there is some potential for successful subseasonal forecasts of spring onset, as indices from most regions are significantly correlated with antecedent large-scale modes of variability.
Trost, Matthias; Bredow, Jan; Boese, Christoph Kolja; Loweg, Lennard; Schulte, Tobias Ludger; Scaal, Martin; Eysel, Peer; Oppermann, Johannes
Distal chevron osteotomy is a common procedure for surgical correction of hallux valgus. Osteosynthesis with 1 screw or 2 Kirschner wires has been commonly used. We compared the stability of the 2 techniques in distal chevron osteotomy. Sixteen first metatarsals from fresh-frozen human cadaver feet (9 different cadaveric specimens) were used. A standardized distal chevron osteotomy was performed. One first metatarsal from each pair was assigned to group 1 (3.5-mm cortical screw; n = 8) and one to group 2 (two 1.6-mm Kirschner wires; n = 8). Using a materials testing machine, the head of the first metatarsals was loaded in 2 different configurations (cantilever and physiologic) in succession. In the cantilever configuration, the relative stiffness of the osteosynthesis compared with intact bone was 59% ± 27% in group 1 and 68% ± 18% in group 2 (p = .50). In the physiologic configuration, it was 38% ± 25% in group 1 and 35% ± 7% in group 2 (p = .75). The failure strength in the cantilever configuration was 187 ± 105 N in group 1 and 259 ± 71 N in group 2 (p = .21). No statistically significant differences were found in stability between the 2 techniques. The use of 1 screw or 2 Kirschner wires had no significant differences in their biomechanical loading capacity for osteosynthesis in distal chevron osteotomies for treatment of hallux valgus. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Lopes, Hélio P; Gambarra-Soares, Thaiane; Elias, Carlos N; Siqueira, José F; Inojosa, Inês F J; Lopes, Weber S P; Vieira, Victor T L
2013-04-01
This study compared the mechanical properties of endodontic instruments made of conventional nickel-titanium (NiTi) wire (K(3) and Revo-S SU), M-Wire (ProFile Vortex), or NiTi alloy in R-phase (K(3)XF). The test instruments were subjected to mechanical tests to evaluate resistance to bending (flexibility), cyclic fatigue, and torsional load in clockwise rotation. Data were statistically evaluated by the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. In the bending resistance test, flexibility decreased in the following order: K(3)XF > Revo-S SU > ProFile Vortex > K(3). The ranking in the fatigue resistance test was the following: K(3)XF > K(3) > ProFile Vortex > Revo-S SU. In the torsional assay, the angular deflection at failure decreased in the following order: K(3)XF > Revo-S SU > K(3) > ProFile Vortex. For the maximum torque values, the ranking was K(3) > K(3)XF > ProFile Vortex > Revo-S SU. The results showed that the K(3)XF instrument, which is made of NiTi alloy in R-phase, had the overall best performance in terms of flexibility, angular deflection at failure, and cyclic fatigue resistance. In addition to the alloy from which the instrument is manufactured, the design and dimensions are important determinants of the mechanical performance of endodontic instruments. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Fischer, Caleb Nathaniel
2011-09-01
Dr. Jo Handelsman, Howard Hughes Medical Institute Professor in the Department of Molecular, Cellular and Developmental Biology at Yale University, is a long-time devotee of scientific teaching, receiving this year's Presidential Award for Science Mentoring. She gave a seminar entitled "What is Scientific Teaching? The Changing Landscape of Science Education" as a part of the Scientific Education Colloquia Series in spring 2011. After dissecting what is wrong with the status quo of American scientific education, several ideological and practical changes are proposed, including active learning, regular assessment, diversity, and mentorship. Copyright © 2011.
USDA-ARS?s Scientific Manuscript database
Healthy plant communities of the American sagebrush-steppe consist of mostly wind-pollinated shrubs and grasses interspersed with a diverse mix of mostly spring-blooming, herbaceous perennial wildflowers. Native, non-social bees are the common floral visitors, but their floral associations and abund...
Harm Reduction for Cannabis: Factor Analysis of a Protective Behavioral Strategies Survey
ERIC Educational Resources Information Center
Caffrey, Kathleen S.; Wright, Bruce R.; Maarhuis, Patricia L.
2018-01-01
Objective: To examine the psychometric properties of a measure of cannabis-specific Protective Behavioral Strategies (PBS), which assesses ways in which students may reduce cannabis-related risk. Participants: Respondents to the American College Health Association-National College Health Assessment II (N = 580) during Spring 2015. Methods:…
EPP Monitor, Volume 8, Issues 1&2, Spring/Summer 2004
ERIC Educational Resources Information Center
Guerrier, Martine
2004-01-01
This issue of EPP Monitor contains the following articles: "Countdown for Justice," Five Quick and Inexpensive Ways to End Overcrowding," "Third Grade Retention -- Deja Vu All Over Again," High-Need African-American and Latino Students Doing Better in Suburban Districts," "An Emerging Consensus on Facts, not…
Health Behaviors of Culturally Diverse Inner-City Community College Students
ERIC Educational Resources Information Center
Heller, Janet R.; Sarmiento, Ariel L.
2016-01-01
Objective: To determine the prevalence of risk behaviors related to cigarette use, alcohol use, nutrition, physical fitness, and sexual behavior. Participants: Participants were 1,075 students attending an urban community college during the Spring 2012 semester. Methods: Data were collected in randomly selected classes using the American College…
Psychosomatic Medicine: A New Psychiatric Subspecialty
ERIC Educational Resources Information Center
Gitlin, David F.; Levenson, James L.; Lyketsos, Constantine G.
2004-01-01
Objective: Psychosomatic medicine, also known as consultation-liaison psychiatry, received approval as a subspecialty field of psychiatry by the American Board of Medical Specialties in the spring of 2003. This represents a crucial step in the development of the field of psychosomatic medicine and recognition by leaders in the fields of medicine…
Grading Rubrics: Hoopla or Help?
ERIC Educational Resources Information Center
Howell, Rebecca J.
2014-01-01
The purpose of the study was to offer some quantitative, multivariate evidence concerning the impact of grading rubric use on academic outcome among American higher education students. Using a pre-post, quasi-experimental research design, cross-sectional data were derived from undergraduates enrolled in an elective during spring and fall 2009 at…
Agricultural landscapes serve as active amphibian breeding grounds despite their seemingly poor habitat value. Activity of adults and dispersal of metamorphs to and from agricultural ponds occurs in most species from spring through late summer or early fall, a time that coincides...
NASA Astrophysics Data System (ADS)
Papers given at the 1988 AGU Spring Meeting continue to make news. Representatives from 12 magazines, 5 newspapers, 2 wire services, and a TV station used the press room and attended the 6 news conferences. The journalists were attracted to the meeting, held May 16-20 in Baltimore, Md., by 6 press releases mailed out by the AGU public information staff in the 2 months before the meeting. Correspondents from as far as Sweden and Japan joined U.S. reporters from San Francisco, New York, Washington, D.C. and Baltimore.A count of clippings received by June 6 shows that by May 17, the second day of the meeting, newspapers in 36 states had published articles; that translates to a potential readership of 5 million. News clippings are still arriving, so figures are preliminary.
Rhabdomyosarcoma associated with the lead wire of a pacemaker generator implant.
Thieman Mankin, Kelley M; Dunbar, Mark D; Toplon, David; Ginn, Pamela; Maisenbacher, Herbert W; Risselada, Marije
2014-06-01
An 11-year-old female spayed Labrador Retriever was presented for a draining, painful subcutaneous mass palpated over a previously implanted pacemaker generator. Infection was suspected and the mass was removed surgically. On cut surface, the mass was friable and mottled tan to brown with firm pale tan nodules, surrounding the pacemaker lead wire adjacent to the pacemaker generator. Cytologic interpretation of impression smears was consistent with a sarcoma, and suggestive of a rhabdomyosarcoma due to the presence of strap-like cells. On histopathologic examination, a highly invasive nodular mass surrounded the pacemaker lead, composed of pleomorphic round, spindle and strap cells, and multinucleated giant cells. The population exhibited microscopic invasion into the deep portion of the fibrous capsule surrounding the pacemaker generator. There were tumor emboli within small to medium subcutaneous veins adjacent to the mass. Immunohistochemically, the neoplastic cells stained positive for α-sarcomeric actin and vimentin, and negative for α-smooth muscle actin, consistent with a rhabdomyosarcoma arising at the site of the pacemaker generator. To our knowledge, this is the first report of a rhabdomyosarcoma associated with the lead wire of a pacemaker generator in a dog. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Yan, Rongliang; Qu, Jiafu; Cao, Lihai; Liu, Hongda; Chen, Jianghua; Gao, Yan; Peng, Yi
2018-05-01
To summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture. Between January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score. All incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%. The procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.
Acculturation and weight change in Asian-American children: Evidence from the ECLS-K:2011.
Diep, Cassandra S; Baranowski, Tom; Kimbro, Rachel T
2017-06-01
Despite relatively low rates of overweight and obesity among Asian-American children, disparities exist based on acculturation, socioeconomic status, and Asian ethnicity. The purpose of this study was to examine the association between acculturation and weight change in Asian-American children. Secondary aims were to compare changes by Asian ethnic group and acculturation x socioeconomic status. Participants included 1200 Asian-American children from the Early Childhood Longitudinal Study, Kindergarten Class of 2010-11, a longitudinal study of U.S. children attending kindergarten in 2010-2011. Multinomial logistic regressions were conducted to predict weight change based on body mass indices in kindergarten (spring 2011) and second grade (spring 2013): consistently healthy weight, consistently overweight/obese, healthy weight change, and unhealthy weight change. Models included demographic, household, socioeconomic status, and acculturation measures, specifically mother's English proficiency and percentage of life spent in the U.S. Overall, 72.3% of children were at healthy weights in kindergarten and second grade. Of all Asian ethnic groups, Filipino children had the highest rate of being consistently overweight/obese (24.8%) and the lowest rate of being consistently healthy weight (62.9%). In addition, mother's English proficiency predicted unhealthy weight change (OR: 0.83; 95% CI: 0.75-0.92) and healthy weight change (OR: 0.75; 95% CI: 0.65-0.86), relative to "consistently healthy weight." English proficiency also predicted being consistently overweight/obese for children with less educated mothers. Findings enhance our understanding of obesity disparities within Asian Americans and highlight the need to disaggregate the population. Obesity interventions are needed for Filipino children and families with low socioeconomic status but high English proficiency. Copyright © 2017 Elsevier Inc. All rights reserved.
Beatty, William S.; Webb, Elisabeth B.; Kesler, Dylan C.; Naylor, Luke W.; Raedeke, Andrew H.; Humburg, Dale D.; Coluccy, John M.; Soulliere, G.
2015-01-01
Bird conservation Joint Ventures are collaborative partnerships between public agencies and private organizations that facilitate habitat management to support waterfowl and other bird populations. A subset of Joint Ventures has developed energetic carrying capacity models (ECCs) to translate regional waterfowl population goals into habitat objectives during the non-breeding period. Energetic carrying capacity models consider food biomass, metabolism, and available habitat to estimate waterfowl carrying capacity within an area. To evaluate Joint Venture ECCs in the context of waterfowl space use, we monitored 33 female mallards (Anas platyrhynchos) and 55 female American black ducks (A. rubripes) using global positioning system satellite telemetry in the central and eastern United States. To quantify space use, we measured first-passage time (FPT: time required for an individual to transit across a circle of a given radius) at biologically relevant spatial scales for mallards (3.46 km) and American black ducks (2.30 km) during the non-breeding period, which included autumn migration, winter, and spring migration. We developed a series of models to predict FPT using Joint Venture ECCs and compared them to a biological null model that quantified habitat composition and a statistical null model, which included intercept and random terms. Energetic carrying capacity models predicted mallard space use more efficiently during autumn and spring migrations, but the statistical null was the top model for winter. For American black ducks, ECCs did not improve predictions of space use; the biological null was top ranked for winter and the statistical null was top ranked for spring migration. Thus, ECCs provided limited insight into predicting waterfowl space use during the non-breeding season. Refined estimates of spatial and temporal variation in food abundance, habitat conditions, and anthropogenic disturbance will likely improve ECCs and benefit conservation planners in linking non-breeding waterfowl habitat objectives with distribution and population parameters. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
NASA Astrophysics Data System (ADS)
Hanrahan, T. P.; Hill, Z.; Levell, A.; Maguire, T.; Risso, D.
2014-12-01
A large wetland and floodplain complex adjacent to the Snake River in southeastern Idaho, USA, encompasses numerous spring-fed creeks that originate on the floodplain and discharge at their confluence with the Snake River and American Falls Reservoir. Resource managers are implementing a program to restore these spring creeks for the recovery of Yellowstone cutthroat trout and ecosystem health. Our objectives were to evaluate the physical characteristics of these spring creeks, develop a conceptual model of their geomorphic function, compare the restoration potential of individual reaches, and communicate our findings to a broad audience of resource managers and regional stakeholders in order to foster restoration planning. A geomorphic assessment along 38 km of three spring creeks was completed by collecting data at several transects within distinct geomorphic reaches, and by collecting data continuously throughout all reaches. These data were summarized in a GIS database and used to quantify the overall geomorphic functioning of each reach. The geomorphic functional scores were scaled from 0% (non-functional) to 100% (fully functional). Among all three spring creeks, geomorphic function ranged from 29% to 63%, with bank conditions and riparian vegetation being the primary causes of overall channel degradation. Results from the geomorphic assessment fostered the development of a conceptual model for spring creek function, whereby degraded bank conditions represent the primary controlling factor of decreased geomorphic function and fish habitat quality. The reach-based geomorphic functional scoring provides an indicator of relative restoration potential for each reach, and is one of the factors used in determining site-specific priorities for protecting, enhancing, and restoring spring creeks on the Fort Hall Bottoms. The study results, conceptual model and restoration strategy were communicated to resource managers and regional stakeholders through a graphically-rich, large format atlas document. Presentation of hard copy and electronic versions of maps and infographics fostered a high level of engagement among those interested in restoring these spring creek systems.
Effect of low-frequency mechanical vibration on orthodontic tooth movement.
Yadav, Sumit; Dobie, Thomas; Assefnia, Amir; Gupta, Himank; Kalajzic, Zana; Nanda, Ravindra
2015-09-01
Our objective was to investigate the effect of low-frequency mechanical vibration (LFMV) on the rate of tooth movement, bone volume fraction, tissue density, and the integrity of the periodontal ligament. Our null hypothesis was that there would be no difference in the amount of tooth movement between different values of LFMV. Sixty-four male CD1 mice, 12 weeks old, were used for orthodontic tooth movement. The mice were randomly divided into 2 groups: control groups (baseline; no spring + 5 Hz; no spring + 10 Hz; and no spring + 20 Hz) and experimental groups (spring + no vibration; spring + 5 Hz; spring + 10 Hz; and spring + 20 Hz). In the experimental groups, the first molars were moved mesially for 2 weeks using nickel-titanium coil springs delivering 10 g of force. In the control and experimental groups, LFMV was applied at 5, 10, or 20 Hz. Microfocus x-ray computed tomography analysis was used for tooth movement measurements, bone volume fraction, and tissue density. Additionally, immunostaining for sclerostin, tartrate-resistant acid phosphatase (TRAP) staining, and picrosirius red staining were used on the histologic sections. Simple descriptive statistics were used to summarize the data. Kruskal-Wallis tests were used to compare the outcomes across treatment groups. LFMV did not increase the rate of orthodontic tooth movement. Microfocus x-ray computed tomography analysis showed increases in bone volume fractions and tissue densities with applications of LFMV. Sclerostin expression was decreased with 10 and 20 Hz vibrations in both the control and experimental groups. Additionally, the picrosirius staining showed that LFMV helped in maintaining the thickness and integrity of collagen fibers in the periodontal ligament. There was no significant increase in tooth movement by applying LFMV when compared with the control groups (spring + no vibration). Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Historical Footage of John Glenn Friendship 7
NASA Technical Reports Server (NTRS)
1962-01-01
The Friendship mission launch on the 20th day of February marked the first time that an American attempts to orbit the Earth. Historical footage of John Glenn's suit up, ride out to the launch pad, countdown, liftoff, booster engine cutoff, and separation of the booster engine escape tower is shown. Views of the Earth, Glenn's manual control of the electrical fly-by wire system, and the recovery of the landing vehicle from the ocean are presented.
An improved method to monitor nest attentiveness using radio-telemetry
Licht, D.S.; McAuley, D.G.; Longcore, J.R.; Sepik, G.F.
1989-01-01
An improved method of automatically monitoring nest attentiveness was designed and tested using radio-equipped American Woodcock (Scolopax minor). Shielded coaxial cable (RG-58) was extended from a receiver and placed 30 cm above the nest, with a 3.8 cm section of the inner wire exposed. Presence, absence, and activity of birds within 10.1 ? 5.2 m (SD) of the nest were clearly indicated on a Rustrak recorder while extraneous signal interference was minimized.
Turning Point: Operation Allied Force and the Allure of Air Power
2014-06-13
naval bombardments that disfigure the history of Great Britain in the late eighteenth century. ― H.G. Wells, The War in the Air, 1908 Herbert ...over Libya. He found the right moment to end the campaign through the same medium that galvanized its beginnings. Spencer Ackerman of Wired...Hugh. Without Hesitation: The Odyssey of an American Warrior. New York: St. Martin’s Press, 2010. Wells, Herbert George. The War in the Air. London
Are running speeds maximized with simple-spring stance mechanics?
Clark, Kenneth P; Weyand, Peter G
2014-09-15
Are the fastest running speeds achieved using the simple-spring stance mechanics predicted by the classic spring-mass model? We hypothesized that a passive, linear-spring model would not account for the running mechanics that maximize ground force application and speed. We tested this hypothesis by comparing patterns of ground force application across athletic specialization (competitive sprinters vs. athlete nonsprinters, n = 7 each) and running speed (top speeds vs. slower ones). Vertical ground reaction forces at 5.0 and 7.0 m/s, and individual top speeds (n = 797 total footfalls) were acquired while subjects ran on a custom, high-speed force treadmill. The goodness of fit between measured vertical force vs. time waveform patterns and the patterns predicted by the spring-mass model were assessed using the R(2) statistic (where an R(2) of 1.00 = perfect fit). As hypothesized, the force application patterns of the competitive sprinters deviated significantly more from the simple-spring pattern than those of the athlete, nonsprinters across the three test speeds (R(2) <0.85 vs. R(2) ≥ 0.91, respectively), and deviated most at top speed (R(2) = 0.78 ± 0.02). Sprinters attained faster top speeds than nonsprinters (10.4 ± 0.3 vs. 8.7 ± 0.3 m/s) by applying greater vertical forces during the first half (2.65 ± 0.05 vs. 2.21 ± 0.05 body wt), but not the second half (1.71 ± 0.04 vs. 1.73 ± 0.04 body wt) of the stance phase. We conclude that a passive, simple-spring model has limited application to sprint running performance because the swiftest runners use an asymmetrical pattern of force application to maximize ground reaction forces and attain faster speeds. Copyright © 2014 the American Physiological Society.
Fujisaki, Ikuko; Rice, Kenneth G.; Pearlstine, Leonard G.; Mazzotti, Frank J.
2009-01-01
Feeding opportunities of American alligators (Alligator mississippiensis) in freshwater wetlands in south Florida are closely linked to hydrologic conditions. In the Everglades, seasonally and annually fluctuating surface water levels affect populations of aquatic organisms that alligators consume. Since prey becomes more concentrated when water depth decreases, we hypothesized an inverse relationship between body condition and water depth in the Everglades. On average, condition of adult alligators in the dry season was significantly higher than in the wet season, but this was not the case for juveniles/subadults. The correlation between body condition and measured water depth at capture locations was weak; however, there was a significant negative correlation between the condition and predicted water depth prior to capture for all animals except for spring juveniles/subadults which had a weak positive condition-water depth relationship. Overall, a relatively strong inverse correlation occurred at 10-49 days prior to the capture day, suggesting that current body condition of alligators may depend on feeding opportunities during that period. Fitted regression of body condition on water depth (mean depth of 10 days when condition-water depth correlation was greatest) resulted in a significantly negative slope, except for spring adult females and spring juveniles/subadults for which slopes were not significantly different from zero. Our results imply that water management practices may be critical for alligators in the Everglades since water depth can affect animal condition in a relatively short period of time.
ERIC Educational Resources Information Center
Asquith, Christina
2007-01-01
Last spring, at the height of the frenzy over accusations that three Duke University men's lacrosse players had gang raped a Black exotic dancer during a party, faculty from Duke's African and African American studies department chose to take a stand. With emotions running high, the faculty took out a full-page advertisement in student newspaper,…
Dictionary of Afro-American Slang.
ERIC Educational Resources Information Center
Major, Clarence
The speech habits of the most oppressed --and the largest-- segment of the black population in the United States did not spring solely from an inability to handle acceptable forms of spoken English, nor mainly from the limitations caused by the particular stock of words known to the speaker. Black slang stems from a somewhat disseminated rejection…
Rural Special Education Quarterly, Volume 5, Nos. 1-4, Spring-Fall 1984, Winter 1985.
ERIC Educational Resources Information Center
Rural Special Education Quarterly, 1985
1985-01-01
Four newsletter issues examine aspects of rural special education. Issue number one considers the generic problems or solutions in rural special education leadership, the need for innovative preservice preparation for rural educators, preservice training for Native American professionals and paraprofessionals, a model for rural early intervention,…
Multiple Health Behaviors and Psychological Well-Being of Chinese Female Undergraduate Students
ERIC Educational Resources Information Center
Bian, Hui; Wu, Jingjin; Li, Yan; Largo-Wight, Erin
2012-01-01
This study examined Chinese female college students' multiple health behaviors, their quality of life, and mental and psychological well-being and compared that with American counterparts. A convenience sample of 293 female undergraduates participated in the study during spring 2010, in Eastern China. A traditional self-report paper-pencil…
Microhabitat Characteristics of sites used by swamp rabbits
Patrick A. Zollner; Winston P. Smith; Leonard A. Brennan
2000-01-01
The swamp rabbit (Sylvilagus aquaticus) is one of the least studied North American lagomorphs; a better understanding of the habitat types it uses will improve management of this species. We studied microhabitat characteristics of sites associated with specific behaviors of the swamp rabbit. During spring-summer (15 April-1 October) and fall-winter (...
A "Service-Learning Approach" to Teaching Computer Graphics
ERIC Educational Resources Information Center
Hutzel, Karen
2007-01-01
The author taught a computer graphics course through a service-learning framework to undergraduate and graduate students in the spring of 2003 at Florida State University (FSU). The students in this course participated in learning a software program along with youths from a neighboring, low-income, primarily African-American community. Together,…
"Changing Places" in Changed Times
ERIC Educational Resources Information Center
Showalter, Elaine
2008-01-01
Thirty years ago, every American academic going on a research trip or a sabbatical to England carried a copy of David Lodge's comic classic, "Changing Places" (1975), which told a tale of two 40-year-old professors of English literature and two embattled campuses in the eventful spring of 1969. An ineffectual British academic, Philip…
ERIC Educational Resources Information Center
Baiio, Wasang; Ray, Waverly C.
2011-01-01
In the spring of 2007, approximately 50 undergraduate introductory geography students in Papua New Guinea and the United States participated in a four-week international collaboration using the nationalism module available from the Association of American Geographers' Center for Global Geography Education. This paper reports on the challenges and…
Sculpture, view looking to pair of lions, positioned at top ...
Sculpture, view looking to pair of lions, positioned at top of stairs leading down into the Glen from DeWitt Circle, just north of the American Bungalow (note: Windmill in background) - National Park Seminary, Bounded by Capitol Beltway (I-495), Linden Lane, Woodstove Avenue, & Smith Drive, Silver Spring, Montgomery County, MD
Update on Research and Leadership, Fall 2001-Spring 2002.
ERIC Educational Resources Information Center
Barnett, Elisabeth, Ed.
2001-01-01
This issue of On Research and Leadership Update (v13 n1) focuses on the concerns surrounding dual enrollment and dual credit. "Dual Enrollment Programs: Assessing the American Dream," by Katherine Boswell, addresses the problems inherent in development of these programs when institutions fail to collaborate with one another in an effective way.…
Conspicuous Consumption in Higher Education: The Case of Academic Bling
ERIC Educational Resources Information Center
Vander Schee, Brian A.
2011-01-01
Spring is a time for gardening, blossoms, and baseball. At American college and universities, it is also a time for commencement ceremonies. Students are recognized for their scholastic achievements as faculty and staff close out another academic school year. Family and friends applaud the graduates and celebrate their success. Students show their…
Outline of the Course in Automated Language Processing.
ERIC Educational Resources Information Center
Pacak, M.; Roberts, A. Hood
The course in computational linguistics described in this paper was given at The American University during the spring semester of 1969. The purpose of the course was "to convey to students with no previous experience an appreciation of the growing art of computational linguistics which encompasses every use to which computers can be put in…
ERIC Educational Resources Information Center
Gehring, John
2005-01-01
Childhood obesity may be an epidemic for American children in general, but experts say that for severely disabled youth, it is even worse. This article describes how in the spring of 2005, national leaders addressed the issue of childhood obesity particularly as it relates to disabled children. It was at this time that Secretary Tommy Thompson of…
Learning from American Street Gangs: Fighting Insurgency in Iraq
2006-01-01
including structures, demographics, identities, motivations, and tactics. This section uses definitions of insurgency in its application to...http://fletcher.tufts.edu/al_nakhlah/archives/spring2004/ruvalcaba.pdf> (21 November 2005), Article 7. Ruvalcaba uses insurgency categories...these conditions exist in Iraq today. Former Ba’athists 10 Ibid. 11 Gentrification is an example I
1983 Salaries. Society Membership Survey. AIP Report.
ERIC Educational Resources Information Center
Skelton, W. Keith; And Others
Variation and changes in the salaries of members of the American Institute of Physics are examined. Graphics highlighting some of the patterns are presented, along with detailed tables and brief summary text. The data are based on a sample survey of the United Statess members conducted in spring 1983. The overall response rate was 69%, Tables…
Hunter, Shelby L.; Ashworth, Chad E.; Smith, S. Jerrod
2017-09-26
In February 2017, the Grand River Dam Authority filed to relicense the Pensacola Hydroelectric Project with the Federal Energy Regulatory Commission. The predominant feature of the Pensacola Hydroelectric Project is Pensacola Dam, which impounds Grand Lake O’ the Cherokees (locally called Grand Lake) in northeastern Oklahoma. Identification of information gaps and assessment of project effects on stakeholders are central aspects of the Federal Energy Regulatory Commission relicensing process. Some upstream stakeholders have expressed concerns about the dynamics of sedimentation and flood flows in the transition zone between major rivers and Grand Lake O’ the Cherokees. To relicense the Pensacola Hydroelectric Project with the Federal Energy Regulatory Commission, the hydraulic models for these rivers require high-resolution bathymetric data along the river channels. In support of the Federal Energy Regulatory Commission relicensing process, the U.S. Geological Survey, in cooperation with the Grand River Dam Authority, performed bathymetric surveys of (1) the Neosho River from the Oklahoma border to the U.S. Highway 60 bridge at Twin Bridges State Park, (2) the Spring River from the Oklahoma border to the U.S. Highway 60 bridge at Twin Bridges State Park, and (3) the Elk River from Noel, Missouri, to the Oklahoma State Highway 10 bridge near Grove, Oklahoma. The Neosho River and Spring River bathymetric surveys were performed from October 26 to December 14, 2016; the Elk River bathymetric survey was performed from February 27 to March 21, 2017. Only areas inundated during those periods were surveyed.The bathymetric surveys covered a total distance of about 76 river miles and a total area of about 5 square miles. Greater than 1.4 million bathymetric-survey data points were used in the computation and interpolation of bathymetric-survey digital elevation models and derived contours at 1-foot (ft) intervals. The minimum bathymetric-survey elevation of the Neosho River was 709.18 ft above North American Vertical Datum of 1988, which corresponds to a maximum depth of 34.22 ft. The minimum bathymetric-survey elevation of the Spring River was 714.18 ft above North American Vertical Datum of 1988, which corresponds to a maximum depth of 29.22 ft. The minimum bathymetric-survey elevation of the Elk River was 715.62 ft above North American Vertical Datum of 1988, which corresponds to a maximum depth of 27.78 ft.
Annual Coded Wire Tag Program; Oregon Missing Production Groups, 1996 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Mark A.; Mallette, Christine; Murray, William M.
1998-03-01
This annual report is in fulfillment of contract obligations with Bonneville Power Administration which is the funding source for the Oregon Department of Fish and Wildlife's Annual Coded Wire Tag Program - Oregon Missing Production Groups Project. Tule stock fall chinook were caught primarily in British Columbia and Washington ocean, and Oregon freshwater fisheries. Up-river bright stock fall chinook contributed primarily to Alaska and British Columbia ocean commercial, and Columbia River gillnet and other freshwater fisheries. Contribution of Rogue stock fall chinook released in the lower Columbia River occurred primarily in Oregon ocean commercial and Columbia river gillnet fisheries. Willamettemore » stock spring chinook contributed primarily to Alaska and British Columbia ocean commercial, Oregon freshwater sport and Columbia River gillnet fisheries. Willamette stock spring chinook released by CEDC contributed to similar fisheries as the same stocks released in the Willamette system. Up-river stocks of spring chinook contributed almost exclusively to Columbia River sport fisheries and other freshwater recovery areas. The up-river stocks of Columbia River summer steelhead contributed primarily to the Columbia River gillnet and other freshwater fisheries. Coho ocean fisheries from Washington to California were closed or very limited in 1994 and 1995 (1991 and 1992 broods). This has resulted in a greater average percent of catch for other fishery areas. Coho stocks released by ODFW below Bonneville Dam contributed mainly to Oregon and Washington ocean, Columbia Gillnet and other freshwater fisheries. Coho stocks released in the Klaskanine River and Youngs Bay area had much higher contribution to gillnet fisheries than the other coho releases. Coho stocks released above Bonneville Dam contributed to the same fisheries as those released below Bonneville Dam. Survival rates of salmon and steelhead are influenced, not only by factors in the hatchery (disease, density, diet, size and time of release) but also by environmental factors in the river and ocean. These environmental factors are controlled by large scale weather patterns such as El Nino over which man has no influence. Changes in rearing conditions in the hatchery, over which man has some influence, do impact the survival rates. However, these impacts can be offset by impacts caused by environmental factors. Brood years of salmon and steelhead that were in the ocean during the 1983 El Nino event exhibited poor survival all along the Pacific coast of California, Oregon, and Washington. However, stocks of chinook and coho that entered the ocean in the fall of 1984 following the El Nino experienced remarkably improved survival rates. In some instances, tule fall chinook experienced survival rates almost ten times higher than for the previous brood years of the same stock. Coho salmon released in the Columbia River generally experience better survival rates when released later in the spring. However, for the 1990 brood year June releases of Columbia River coho had much lower survival than May releases, for all ODFW hatcheries. In general survival of ODFW Columbia River hatchery coho has declined to low levels since the 1989 brood year.« less
Offshore springs and seeps are focus of working group
NASA Astrophysics Data System (ADS)
Burnett, Bill
People have been curious about offshore springs and seeps since at least the days of the Romans. In spite of many centuries of both casual and serious observations, there has been relatively little scientific study concerning the magnitude and effects of groundwater flow into the sea. Rather, studies were performed mostly to address water resource issues. Investigations over the past decade or so have now shown that groundwater discharge, at least in some cases, may be important for geochemical budgets and ecological effects.The Scientific Committee on Oceanic Research (SCOR) and the Land-Ocean Interactions in the Coastal Zone (LOICZ) Project of the International Geosphere-Biosphere Program have recently established a working group of experts to examine questions relating specifically to groundwater discharge in the coastal zone. Direct groundwater flow into the ocean is known to occur as springs and seeps in near-shore areas in many parts of the world. Submarine springs, for example, are well known off both coasts of Florida; Mexico's Yucatan Peninsula; in several areas around the Pacific rim including Chile, Hawaii, Guam, American Samoa, and Australia; in the Persian Gulf near Bahrain; in the Mediterranean Sea off Spain, France, Italy, Greece, Syria, Lebanon, Israel, and Libya; and in many other locations.
On the relevance of "ideal" occlusion concepts for incisor inclination target definition.
Knösel, Michael; Jung, Klaus
2011-11-01
The concept of "ideal" occlusion in harmony with craniofacial structures is often proposed as an ultimate goal of orthodontic treatment. The aim of this study was to assess the impact of slight variations in posterior occlusion and the history of straight-wire orthodontic treatment on the predictability of incisor inclination and third-order angles. Axial incisor inclinations, third-order angles, and craniofacial relationships were assessed on lateral headfilms and corresponding dental casts of 75 healthy white subjects, 16 to 26 years old, selected by the general inclusion criterion of a good interincisal relationship. Four groups were formed: group A (n = 17), Angle Class I occlusion subjects with no orthodontic treatment; group B (n = 20), Angle Class I occlusion subjects treated with standardized straight-wire orthodontics; group C (n = 20), up to a half-cusp distal occlusion after straight-wire treatment; and group D (n = 18), up to a half-cusp distal occlusion and no orthodontic treatment. Regression analysis was used to insert predictor angles into selected regression equations of the subjects with "ideal" occlusion, and the absolute differences between predicted and observed response angles were determined. Small differences in incisor inclination were found between subjects with "ideal" occlusion and those who slightly deviated from "ideal" with a mild occlusion of the Angle Class II category. Posterior occlusion was not relevant to the validity of the vast majority of predictor-response pairs. Straight-wire treatment produced incisor inclination that was slightly protruded compared with subjects who had good natural occlusion. The "ideal" posterior occlusion concepts as a general orthodontic treatment goal should be reconsidered. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments.
Shen, Ya; Zhou, Hui-Min; Zheng, Yu-Feng; Campbell, Les; Peng, Bin; Haapasalo, Markus
2011-11-01
To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys and developed new manufacturing processes for the fabrication of NiTi files. This study aimed to examine the phase transformation behavior and microstructure of NiTi instruments from a novel controlled memory NiTi wire (CM wire). Instruments of EndoSequence (ES), ProFile (PF), ProFile Vortex (Vortex), Twisted Files (TF), Typhoon (TYP), and Typhoon™ CM (TYP CM), all size 25/.04, were examined by differential scanning calorimetry (DSC) and x-ray diffraction (XRD). Microstructures of etched instruments were observed by optical microscopy and scanning electron microscopy with x-ray energy-dispersive spectrometric (EDS) analyses. The DSC analyses showed that each segment of the TYP CM and Vortex instruments had an austenite transformation completion or austenite-finish (A(f)) temperature exceeding 37°C, whereas the NiTi instruments made from conventional superelastic NiTi wire (ES, PF, and TYP) and TF had A(f) temperatures substantially below mouth temperature. The higher A(f) temperature of TYP CM instruments was consistent with a mixture of austenite and martensite structure, which was observed at room temperature with XRD. All NiTi instruments had room temperature martensite microstructures consisting of colonies of lenticular features with substantial twinning. EDS analysis indicated that the precipitates in all NiTi instruments were titanium-rich, with an approximate composition of Ti(2)Ni. The TYP CM and Vortex instruments with heat treatment contribute to increase austenite transformation temperature. The CM instrument has significant changes in the phase transformation behavior, compared with conventional superelastic NiTi instruments. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Rodrigues, Clarissa Teles; Duarte, Marco Antonio Hungaro; de Almeida, Marcela Milanezi; de Andrade, Flaviana Bombarda; Bernardineli, Norberti
2016-11-01
The aim of this ex vivo study was to evaluate the removal of filling material after using CM-wire, M-wire, and nickel-titanium instruments in both reciprocating and rotary motions in curved canals. Thirty maxillary lateral incisors were divided into 9 groups according to retreatment procedures: Reciproc R25 followed by Mtwo 40/.04 and ProDesign Logic 50/.01 files; ProDesign R 25/.06 followed by ProDesign Logic 40/.05 and ProDesign Logic 50/.01 files; and Gates-Glidden drills, Hedström files, and K-files up to apical size 30 followed by K-file 40 and K-file 50 up to the working length. Micro-computed tomography scans were performed before and after each reinstrumentation procedure to evaluate root canal filling removal. Statistical analysis was performed with Kruskal-Wallis, Friedman, and Wilcoxon tests (P < .05). No significant differences in filling material removal were found in the 3 groups of teeth. The use of Mtwo and ProDesign Logic 40/.05 rotary files did not enhance filling material removal after the use of reciprocating files. The use of ProDesign Logic 50/.01 files significantly reduced the amount of filling material at the apical levels compared with the use of reciprocating files. Association of reciprocating and rotary files was capable of removing a large amount of filling material in the retreatment of curved canals, irrespective of the type of alloy of the instruments. The use of a ProDesign Logic 50/.01 file for apical preparation significantly reduced the amount of remnant material in the apical portion when compared with reciprocating instruments. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Park, Kyung-Hwa; Greenwood-Quaintance, Kerryl E; Schuetz, Audrey N; Mandrekar, Jayawant N; Patel, Robin
2017-02-01
We developed a rat model of methicillin-resistant Staphylococcus epidermidis (MRSE) foreign body-associated osteomyelitis and used it to compare tedizolid alone and in combination with rifampin against rifampin alone, vancomycin plus rifampin, and vancomycin alone. A clinical strain of MRSE was inoculated into the proximal tibia, and a stainless steel wire with a precolonized MRSE biofilm was implanted. Following a 1-week infection period, 92 rats received either no treatment (n = 17) or 14 days of intraperitoneal tedizolid (n = 15), tedizolid plus rifampin (n = 15), rifampin (n = 15), vancomycin plus rifampin (n = 15), or vancomycin (n = 15). Quantitative bone and wire cultures were performed after treatment completion and also 1 week after infection in a separate group of five rats. The median quantity of staphylococci in bone after the 1-week infection period was 4.89 log 10 CFU/g bone (interquartile range, 3.83 to 5.33 log 10 CFU/g bone); staphylococci were recovered from all associated wires. A median quantity of staphylococci of 3.70 log 10 CFU/g bone was detected in bones of untreated control rats after 3 weeks. Quantities of staphylococci in bones of all treatment groups except the group receiving vancomycin alone (2.78 log 10 CFU/g) were significantly lower than those for untreated controls, with no staphylococci being detected in the groups receiving rifampin monotherapy, tedizolid-plus-rifampin combination therapy, and vancomycin-plus-rifampin combination therapy. Quantities of staphylococci on wires from all treatment groups that included rifampin were significantly lower than those for untreated controls. No resistance to rifampin, tedizolid, or vancomycin was detected. Tedizolid combined with rifampin was active in a rat model of MRSE foreign body-associated osteomyelitis. Copyright © 2017 American Society for Microbiology.
1980-11-01
Comunicaciones , S.A. Elizabeth, NJ Zaragoza, SPAIN Ilmercable Corporation Cabot Corporation El Dorado, Arkansas Boston, MA American Hoechst Corporation...FILLING RELATIONSHIP TO TRANSMISSION, V. Abadia, J. Z. COMPOUND, D. M. Mitchell, R. Sabia, Bell Lab- Avalos, Cables de Comunicaciones , S. A., Zaragoza...RESISTANCE PROBLEMS AND ITS RELATIONSHIP TO TRANSMISSION V. Abadia and J.Z. Avalos CABLES DE COMUNICACIONES , S,A, ABSTRACT TABLE I A good number of
2013-08-30
turntable inside the hood to maintain a constant weld speed, while the ER308L stainless steel wire were fed by the welding gun. Figure 2. Fume chamber...size distribution, density and specific surface area of welding fumes from SMAW and GMAW mild- steel and stainless - steel consumables, American...shipyards. It uses mild or stainless steel filler material to join pieces of metal. The intense energy expended in the welding process results in the
Scholefield, R.J.; Slaght, K.S.; Stephens, B.E.
2008-01-01
We evaluated the sensitivity of larval sea lampreys Petromyzon marinus to the lampricide 3-trifluoromethyl-4-nitrophenol (TFM) in a series of toxicity tests in spring and summer. Although noted previously, the seasonal variation in sensitivity to TFM had never been tested as a means of reducing TFM usage in stream treatments. A preliminary study consisted of three spring and four summer static toxicity tests conducted at 12??C. A more comprehensive study consisted of 12 spring and summer paired flow-through toxicity tests conducted both at seasonal water temperatures and at 12??C. The sensitivity of larval sea lampreys to TFM was greater in spring than in summer. The preliminary static toxicity tests indicated that the concentration of TFM needed to kill larval sea lampreys in spring (May and June) was about one-half that required in summer (August); the concentrations lethal to 50% and 99.9% of the test animals (the LC50 and LC99.9 values) were less in spring than in summer. Analysis of variance of the flow-through toxicity data indicated that season significantly affected both the LC50 and LC99.9 values. For all 12 paired flow-through toxicity tests, the spring LC50 and LC99.9 values were less than the corresponding summer values. For 9 of the 12 paired flow-through toxicity tests, the dose-response toxicity lines were parallel and allowed statistical comparison of the LC50 values. The spring LC50 values were significantly lower than the summer values in eight of the nine tests. Verification of a seasonal variation in the sensitivity of larval sea lampreys to TFM will allow inclusion of this factor in the selection model currently used by both the U.S. Fish and Wildlife Service and the Department of Fisheries and Oceans-Canada to schedule lampricide stream treatments. ?? Copyright by the American Fisheries Society 2008.
The modeling and design of the Annular Suspension and Pointing System /ASPS/. [for Space Shuttle
NASA Technical Reports Server (NTRS)
Kuo, B. C.; Lin, W. C. W.
1979-01-01
The Annular Suspension and Pointing System (ASPS) is a payload auxiliary pointing device of the Space Shuttle. The ASPS is comprised of two major subassemblies, a vernier and a coarse pointing subsystem. The three functions provided by the ASPS are related to the pointing of the payload, centering the payload in the magnetic actuator assembly, and tracking the payload mounting plate and shuttle motions by the coarse gimbals. The equations of motion of a simplified planar model of the ASPS are derived. Attention is given to a state diagram of the dynamics of the ASPS with position-plus-rate controller, the nonlinear spring characteristic for the wire-cable torque of the ASPS, the design of the analog ASPS through decoupling and pole placement, and the time response of different components of the continuous control system.
NASA Technical Reports Server (NTRS)
2003-01-01
Topics covered include: Stable, Thermally Conductive Fillers for Bolted Joints; Connecting to Thermocouples with Fewer Lead Wires; Zipper Connectors for Flexible Electronic Circuits; Safety Interlock for Angularly Misdirected Power Tool; Modular, Parallel Pulse-Shaping Filter Architectures; High-Fidelity Piezoelectric Audio Device; Photovoltaic Power Station with Ultracapacitors for Storage; Time Analyzer for Time Synchronization and Monitor of the Deep Space Network; Program for Computing Albedo; Integrated Software for Analyzing Designs of Launch Vehicles; Abstract-Reasoning Software for Coordinating Multiple Agents; Software Searches for Better Spacecraft-Navigation Models; Software for Partly Automated Recognition of Targets; Antistatic Polycarbonate/Copper Oxide Composite; Better VPS Fabrication of Crucibles and Furnace Cartridges; Burn-Resistant, Strong Metal-Matrix Composites; Self-Deployable Spring-Strip Booms; Explosion Welding for Hermetic Containerization; Improved Process for Fabricating Carbon Nanotube Probes; Automated Serial Sectioning for 3D Reconstruction; and Parallel Subconvolution Filtering Architectures.
On the Development of Turbulent Wakes from Vortex Streets
NASA Technical Reports Server (NTRS)
Roshko, Anatol
1954-01-01
Wake development behind circular cylinders at Reynolds numbers from 40 to 10,000 was investigated in a low-speed wind tunnel. Standard hot-wire techniques were used to study the velocity fluctuations. The Reynolds number range of periodic vortex shedding is divided into two distinct subranges. At r=40 to 150, called the stable range, regular vortex streets are formed and no turbulent velocity fluctuations accompany the periodic formation of vortices. The range r=150 to 300 is a transition range to a regime called the irregular range, in which turbulent velocity fluctuations accompany the periodic formation of vortices. The turbulence is initiated by laminar-turbulent transition in the free layers which spring from the separation points on the cylinder. The transition first occurs in the range r=150 to 300. Spectrum and statistical measurements were made to study the velocity fluctuations.
Schiffres, Scott N; Malen, Jonathan A
2011-06-01
A novel 3ω thermal conductivity measurement technique called metal-coated 3ω is introduced for use with liquids, gases, powders, and aerogels. This technique employs a micron-scale metal-coated glass fiber as a heater/thermometer that is suspended within the sample. Metal-coated 3ω exceeds alternate 3ω based fluid sensing techniques in a number of key metrics enabling rapid measurements of small samples of materials with very low thermal effusivity (gases), using smaller temperature oscillations with lower parasitic conduction losses. Its advantages relative to existing fluid measurement techniques, including transient hot-wire, steady-state methods, and solid-wire 3ω are discussed. A generalized n-layer concentric cylindrical periodic heating solution that accounts for thermal boundary resistance is presented. Improved sensitivity to boundary conductance is recognized through this model. Metal-coated 3ω was successfully validated through a benchmark study of gases and liquids spanning two-orders of magnitude in thermal conductivity. © 2011 American Institute of Physics
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare...