Sample records for anaerobic power test

  1. Factor Analysis of Various Anaerobic Power Tests.

    ERIC Educational Resources Information Center

    Manning, James M.; And Others

    A study investigated the relationship between selected anthropometric variables and of numerous anaerobic power tests with measures obtained on an isokinetic dynamometer. Thirty-one male college students performed several anaerobic power tests, including: the vertical jump using the Lewis formula; the Margaria-Kalamen stair climb test; the Wingate…

  2. Wingate Anaerobic Test peak power and anaerobic capacity classifications for men and women intercollegiate athletes.

    PubMed

    Zupan, Michael F; Arata, Alan W; Dawson, Letitia H; Wile, Alfred L; Payn, Tamara L; Hannon, Megan E

    2009-12-01

    The Wingate Anaerobic Test (WAnT) has been established as an effective tool in measuring both muscular power and anaerobic capacity in a 30-second time period; however, there are no published normative tables by which to compare WAnT performance in men and women intercollegiate athletics. The purpose of this study was to develop a classification system for anaerobic peak power and anaerobic capacity for men and women National Collegiate Athletic Association (NCAA) Division I college athletes using the WAnT. A total of 1,585 (1,374 men and 211 women) tests were conducted on athletes ranging from the ages of 18 to 25 years using the WAnT. Absolute and relative peak power and anaerobic capacity data were recorded. One-half standard deviations were used to set up a 7-tier classification system (poor to elite) for these assessments. These classifications can be used by athletes, coaches, and practitioners to evaluate anaerobic peak power and anaerobic capacity in their athletes.

  3. Validity and reliability of the Hawaii anaerobic run test.

    PubMed

    Kimura, Iris F; Stickley, Christopher D; Lentz, Melissa A; Wages, Jennifer J; Yanagi, Kazuhiko; Hetzler, Ronald K

    2014-05-01

    This study examined the reliability and validity of the Hawaii anaerobic run test (HART) by comparing anaerobic capacity measures obtained to those during the Wingate Anaerobic Test (WAnT). Ninety-six healthy physically active volunteers (age, 22.0 ± 2.8 years; height, 163.9 ± 9.5 cm; body mass, 70.6 ± 14.7 kg; body fat %, 19.29 ± 5.39%) participated in this study. Each participant performed 2 anaerobic capacity tests: the WAnT and the HART by random assignment on separate days. The reliability of the HART was calculated from 2 separate trials of the test and then determined through intraclass correlation coefficients (ICCs). Blood samples were collected, and lactate was analyzed both pretest and posttest for each of the 2 exercise modes. Heart rate and rate of perceived exertion were also measured pre- and post-exercise. Hawaii anaerobic run test peak and mean momentum were calculated as body mass times highest or average split velocity, respectively. Intraclass correlation coefficients between trials of the HART for peak and mean momentum were 0.98 and 0.99, respectively (SEM = 18.8 and 25.7, respectively). Validity of the HART was established through comparison of momentum on the HART with power on the WAnT. High correlations were found between peak power and peak momentum (r = 0.88), as well as mean power and mean momentum (r = 0.94). The HART was considered to be a reliable test of anaerobic power. The HART was also determined to be a valid test of anaerobic power when compared with the WAnT. When testing healthy college-aged individuals, the HART offers an easy and inexpensive alternative maximal effort anaerobic power test to other established tests.

  4. Wingate Anaerobic Test Peak Power and Anaerobic Capacity Classification for Men and Women Intercollegiate Athletes

    DTIC Science & Technology

    2009-12-01

    Dawson, LH, Wile , AL, Payn, TL, and Hannon, ME. Wingate Anaerobic Test peak power and anaerobic capacity classifications for men and women...139,2007. 6. Chromiah JA, Smedley, B, Carpenter, W, Brown , R, Koh, YS, Lamberth, JG, Joe, LA, Abadie, BR, and Altorfer, G. Effect of 10- week strength...Bnt J Sport Med 38: 784-789,2004. 8. Findley, BW, Brown , LE, and Whitehurst, M. Anaerobic power performance ofincumbent female firefrghters. J

  5. The Relationship between Field Tests of Anaerobic Power and 10-km Run Performance.

    ERIC Educational Resources Information Center

    Sinnett, Aaron M.; Berg, Kris; Latin, Richard W.; Noble, John M.

    2001-01-01

    Investigated the relationship between several field tests of anaerobic power (e.g., +various sprints, vertical jumps, and a plyometric leap) and distance running performance in trained adult male and female runners. Results indicate that anaerobic power is significantly related to distance running performance and may explain a meaningful…

  6. Positional Role Differences in the Aerobic and Anaerobic Power of Elite Basketball Players.

    PubMed

    Pojskić, Haris; Šeparović, Vlatko; Užičanin, Edin; Muratović, Melika; Mačković, Samir

    2015-12-22

    The aim of the present study was to compare the aerobic and anaerobic power and capacity of elite male basketball players who played multiple positions. Fifty-five healthy players were divided into the following three different subsamples according to their positional role: guards (n = 22), forwards (n = 19) and centers (n = 14). The following three tests were applied to estimate their aerobic and anaerobic power and capacities: the countermovement jump (CMJ), a multistage shuttle run test and the Running-based Anaerobic Sprint Test (RAST). The obtained data were used to calculate the players' aerobic and anaerobic power and capacities. To determine the possible differences between the subjects considering their different positions on the court, one-way analysis of variance (ANOVA) with the Bonferroni post-hoc test for multiple comparisons was used. The results showed that there was a significant difference between the different groups of players in eleven out of sixteen measured variables. Guards and forwards exhibited greater aerobic and relative values of anaerobic power, allowing shorter recovery times and the ability to repeat high intensity, basketball-specific activities. Centers presented greater values of absolute anaerobic power and capacities, permitting greater force production during discrete tasks. Coaches can use these data to create more individualized strength and conditioning programs for different positional roles.

  7. Anaerobic and Aerobic Performance of Elite Female and Male Snowboarders

    PubMed Central

    Żebrowska, Aleksandra; Żyła, Dorota; Kania, Damian; Langfort, Józef

    2012-01-01

    The physiological adaptation to training is specific to the muscle activity, dominant energy system involved, muscle groups trained, as well as intensity and volume of training. Despite increasing popularity of snowboarding only little scientific data is available on the physiological characteristics of female and male competitive snowboarders. Therefore, the purpose of this study was to compare the aerobic capacity and maximal anaerobic power of elite Polish snowboarders with untrained subjects. Ten snowboarders and ten aged matched students of Physical Education performed two exercise tests. First, a 30-second Wingate test was conducted and next, a cycle ergometer exercise test with graded intensity. In the first test, peak anaerobic power, the total work, relative peak power and relative mean power were measured. During the second test, relative maximal oxygen uptake and lactate threshold were evaluated. There were no significant differences in absolute and relative maximal oxygen uptake between snowboarders and the control group. Mean maximal oxygen uptake and lactate threshold were significantly higher in men than in women. Significant differences were found between trained men and women regarding maximal power and relative maximal power. The elite snowboarders demonstrated a high level of anaerobic power. The level of relative peak power in trained women correlated negatively with maximal oxygen uptake. In conclusion, our results seem to indicate that the demanding competition program of elite snowboarders provides a significant training stimulus mainly for anaerobic power with minor changes in anaerobic performance. PMID:23487498

  8. Effects of lower extremity injuries on aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function in high school soccer players.

    PubMed

    Ko, Kwang-Jun; Ha, Gi-Chul; Kim, Dong-Woo; Kang, Seol-Jung

    2017-10-01

    [Purpose] The study investigated the effects of lower extremity injuries on aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function in high school soccer players. [Subjects and Methods] The study assessed U High School soccer players (n=40) in S area, South Korea, divided into 2 groups: a lower extremity injury group (n=16) comprising those with knee and ankle injuries and a control group (n=24) without injury. Aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function were compared and analyzed. [Results] Regarding the aerobic exercise capacity test, significant differences were observed in maximal oxygen uptake and anaerobic threshold between both groups. For the anaerobic power test, no significant difference was observed in peak power and average power between the groups; however, a significant difference in fatigue index was noted. Regarding the knee isokinetic muscular test, no significant difference was noted in knee flexion, extension, and flexion/extension ratio between both groups. [Conclusion] Lower extremity injury was associated with reduced aerobic exercise capacity and a higher fatigue index with respect to anaerobic exercise capacity. Therefore, it seems necessary to establish post-injury training programs that improve aerobic and anaerobic exercise capacity for soccer players who experience lower extremity injury.

  9. Off-Ice Anaerobic Power Does Not Predict On-Ice Repeated Shift Performance in Hockey.

    PubMed

    Peterson, Ben J; Fitzgerald, John S; Dietz, Calvin C; Ziegler, Kevin S; Baker, Sarah E; Snyder, Eric M

    2016-09-01

    Peterson, BJ, Fitzgerald, JS, Dietz, CC, Ziegler, KS, Baker, SE, and Snyder, EM. Off-ice anaerobic power does not predict on-ice repeated shift performance in hockey. J Strength Cond Res 30(9): 2375-2381, 2016-Anaerobic power is a significant predictor of acceleration and top speed in team sport athletes. Historically, these findings have been applied to ice hockey although recent research has brought their validity for this sport into question. As ice hockey emphasizes the ability to repeatedly produce power, single bout anaerobic power tests should be examined to determine their ability to predict on-ice performance. We tested whether conventional off-ice anaerobic power tests could predict on-ice acceleration, top speed, and repeated shift performance. Forty-five hockey players, aged 18-24 years, completed anthropometric, off-ice, and on-ice tests. Anthropometric and off-ice testing included height, weight, body composition, vertical jump, and Wingate tests. On-ice testing consisted of acceleration, top speed, and repeated shift fatigue tests. Vertical jump (VJ) (r = -0.42; r = -0.58), Wingate relative peak power (WRPP) (r = -0.32; r = -0.43), and relative mean power (WRMP) (r = -0.34; r = -0.48) were significantly correlated (p ≤ 0.05) to on-ice acceleration and top speed, respectively. Conversely, none of the off-ice tests correlated with on-ice repeated shift performance, as measured by first gate, second gate, or total course fatigue; VJ (r = 0.06; r = 0.13; r = 0.09), WRPP (r = 0.06; r = 0.14; r = 0.10), or WRMP (r = -0.10; r = -0.01; r = -0.01). Although conventional off-ice anaerobic power tests predict single bout on-ice acceleration and top speed, they neither predict the repeated shift ability of the player, nor are good markers for performance in ice hockey.

  10. Motivation and motoric tests in sports.

    PubMed

    Karaba-Jakovljević, Dea; Popadić-Gaćesa, Jelena; Grujić, Nikola; Barak, Otto; Drapsin, Miodrag

    2007-01-01

    Motivation in sport performance has been an interesting topic for many investigators during the past decade. This area can be considered from different viewpoints: motivation for participation in sport activity, achievement motivation, competitiveness etc. Motivation plays an important role in all out tests, as well as in sport activities and at all levels of competition. Motivation climate, or positive social environment may influence and modulate motivation of individuals involved in sports. Experience has shown that conventional encouragement and feedback during the test may affect its outcome. According to Wingate research team recommendations, verbal encouragement, as a motivation factor, was given to all examined subjects during Wingate anaerobic test, which is considered the most reliable test for assessing anaerobic capacity. The investigated group consisted of 30 young men--medical students, who were not actively involved in any programmed sport activity. The investigated group included second-year students of the Faculty of Medicine in Novi Sad chosen by random sampling. The Wingate anaerobic test was performed in all subjects, and changes of parameters when test was performed with verbal encouragement, were recorded The results show statistically significant increase of Wingate test parameters when conducted with verbal encouragement: anaerobic power (622/669 W); relative anaerobic power (7.70/8.27 W/kg); slope of the power (95.5/114 W/s); relative slope of the power (1.18/1.40 W/s/kg); anaerobic capacity (12.7/13.2 kJ) and relative anaerobic capacity (158/164 J/kg).

  11. Does power indicate capacity? 30-s Wingate anaerobic test vs. maximal accumulated O2 deficit.

    PubMed

    Minahan, C; Chia, M; Inbar, O

    2007-10-01

    The purpose of this study was to evaluate the relationship between anaerobic power and capacity. Seven men and seven women performed a 30-s Wingate Anaerobic Test on a cycle ergometer to determine peak power, mean power, and the fatigue index. Subjects also cycled at a work rate predicted to elicit 120 % of peak oxygen uptake to exhaustion to determine the maximal accumulated O (2) deficit. Peak power and the maximal accumulated O (2) deficit were significantly correlated (r = 0.782, p = 0.001). However, when the absolute difference in exercise values between groups (men and women) was held constant using a partial correlation, the relationship diminished (r = 0.531, p = 0.062). In contrast, we observed a significant correlation between fatigue index and the maximal accumulated O (2) deficit when controlling for gender (r = - 0.597, p = 0.024) and the relationship remained significant when values were expressed relative to active muscle mass. A higher anaerobic power does not indicate a greater anaerobic capacity. Furthermore, we suggest that the ability to maintain power output during a 30-s cycle sprint is related to anaerobic capacity.

  12. Fatigue Index and Fatigue Rate during an Anaerobic Performance under Hypohydrations

    PubMed Central

    Naharudin, Mohamed Nashrudin; Yusof, Ashril

    2013-01-01

    Background Since hypohydration commonly occurs in sports, studies on anaerobic exercise performance under this condition have been extensively carried out. When describing anaerobic performance, authors usually refer to a drop in anaerobic performance as fatigue index (FI) which is conventionally calculated using peak and low power data points. Meanwhile, another possible method in explaining anaerobic fatigue is using the rate constant which is derived from the exponential decline of power output known as fatigue rate (FR). Few studies have demonstrated that there was no change in anaerobic performance under mild hypohydrations. Purpose This study aimed to compare the kinetics of power output using FI and FR of an anaerobic performance (Wingate test) under 2, 3 and 4% state of hypohydrations. Method Thirty two collegiate cyclists (age  = 22±2 years; body weight  = 71.45±3.43 kg; height  = 173.23±0.04 cm) were matched using their baseline anaerobic peak power (APP) then randomly divided into 4 groups of EU (euhydrated), 2H, 3H and 4H respectively. Results As expected the, FI, APP, anaerobic lower power (ALP) and rating of perceived exertion (RPE) did not show significant differences between and within the groups. However, the FR in 3H (0.018±0.005s−1) and 4H (0.019±0.010s−1) were significantly lower than EU (0.033±0.012s−1). Post-test FR also showed significant reduction in 3H and 4H compared to their pre-test values (p<0.05). Conclusion Despite the lack of changes in APP and RPE, subjects in 3H and 4H showed evidence of lower reduction of power output over time. The findings support earlier reports which showed no change in anaerobic performance under mild hypohydrations. The relatively lower FR suggests higher drive in maintaining power output under hypohydrations of 3 and 4% body weight. PMID:24204790

  13. Influence of performance level on anaerobic power and body composition in elite male judoists.

    PubMed

    Kim, Jongkyu; Cho, Hyun-Chul; Jung, Han-Sang; Yoon, Jong-Dae

    2011-05-01

    This study examined the relationship between 30-second anaerobic power and body composition by performance level in elite Judoists. During a 3-month period, 10 male Korean Judo national team athletes (NT), 26 male university varsity team athletes (VT), and 28 male junior varsity team athletes (JT) were assessed for 30-second anaerobic power and body composition at the Youngin University. Anaerobic power was measured using a 30-second Wingate test. Body composition was assessed via bioelectric impedance analysis in standardized conditions using BioSpace (Korean)-specific prediction formulas. All testing occurred at the beginning of the winter nonseason period but excluded a brief weight-loss period before the competition phase. Anaerobic power measures were significantly greater (p < 0.05) in NT and VT than in JT. Fat-free mass (FFM), muscle mass (MM), and total body water in JT were also greater than in VT and JT (p < 0.05). Muscle mass in VT was significantly lower than in NT (p < 0.05). Fat-free mass in NT was strongly correlated to mean and peak anaerobic power (r = 0.77, p = 0.009; r = 0.87, p < 0.001, respectively). Varsity team athletes also indicated a moderate association between FFM and peak and mean anaerobic power (r = 0.63, p < 0.001; r = 0.48, p = 0.013, respectively). However, relationship between FFM and anaerobic power was not statistically significantly correlated in JT (r = 0.14, p = 0.470; r = 0.23, p = 0.232, separately). In conclusion, our data indicated that anaerobic power is closely correlated with increase in FFM and MM and was different dependent among performance levels. Further research in the field is warranted to elucidate the Judo-specific relationship between FFM and performance.

  14. Effect of sex and menstrual cycle in women on starting speed, anaerobic endurance and muscle power.

    PubMed

    Wiecek, M; Szymura, J; Maciejczyk, M; Cempla, J; Szygula, Z

    2016-03-01

    The aim of our study was to compare the indicators of starting speed, anaerobic endurance and power in women as well as men, and to investigate whether the values of these indicators differ in women during the follicular and luteal phases of the menstrual cycle. The studied group included 16 men and 16 women. The subjects performed the 20-second maximal cycling sprint test. The men performed the test twice at 14-day intervals. The women undertook the test 4 times: twice during the middle of follicular phase and twice in the middle of luteal phase in separate menstrual cycles. Hormonal changes during the menstrual cycle do not influence anaerobic performance, starting speed or anaerobic endurance in women. Anaerobic performance in men is higher than in women with similar aerobic performance expressed as VO2max/LBM (lean body mass). A lower power decrease with time was noted for women than men, with a similar time of maintaining power in both groups. This is evidence of women's better anaerobic endurance compared to men. At the same time, the men had significantly better starting speed rates than women.

  15. Anaerobic power and physical function in strength-trained and non-strength-trained older adults.

    PubMed

    Slade, Jill M; Miszko, Tanya A; Laity, Jennifer H; Agrawal, Subodoh K; Cress, M Elaine

    2002-03-01

    Challenging daily tasks, such as transferring heavy items or rising from the floor, may be dependent on the ability to generate short bursts of energy anaerobically. The purposes of this study were to determine if strength-trained (ST) older adults have higher anaerobic power output compared with non-strength-trained (NST) older adults and to determine the relationship between anaerobic power and performance-based physical function. Thirty-five men and women (age 71.5 +/- 6.4 years, mean +/- SD; NST: n = 18, ST: n = 17) were grouped by training status. Outcome variables included relative anaerobic power (Wingate test), physical function measured with the Continuous Scale Physical Functional Performance Test (CS-PFP, scaled 0 to 100), and anthropometric lean thigh volume (LTV). Analysis of covariance (with age and sex as covariates) was used to determine group differences in the dependent variables listed above. Pearson's r was used to determine the relationship between anaerobic power, CS-PFP total score (TOT), and CS-PFP lower body strength domain score (LBS). The ST group had significantly higher mean anaerobic power (NST 58.9 +/- 16 W/l, ST 96.3 +/- 23 W/l), CS-PFP total (NST 61.2 +/- 13, ST 73.7 +/- 8), and LBS (NST 54.1 +/- 17, ST 70.9 +/- 8) compared with the NST group (p <.05). However, LTV was similar for both groups (NST 3.323 +/- 0.75; ST 3.179 +/- 0.79), which suggests that the ST group had higher muscle quality compared with the NST group. Anaerobic power was significantly related to TOT (r =.611, p =.001) and LBS (r =.650, p =.001). High levels of physical function in ST older adults may in part be explained by higher levels of anaerobic power associated with strength training.

  16. Anaerobic fitness tests: what are we measuring?

    PubMed

    Van Praagh, Emmanuel

    2007-01-01

    Anaerobic fitness, during growth and development, has not received the same attention from researchers as aerobic fitness. This is surprising given the level of anaerobic energy used daily during childhood and adolescence. During physical activity and sport, the child is spontaneously more attracted to short-burst movements than to long-term activities. It is, however, well known that in anaerobic activities such as sprint cycling, sprint running or sprint swimming, the child's performance is distinctly poorer than that of the adult. This partly reflects the child's lesser ability to generate mechanical energy from chemical energy sources during short-term high-intensity work or exercise. Direct measurements of the rate or capacity of anaerobic pathways for energy turnover presents several ethical and methodological difficulties. Therefore, rather than measure energy supply, pediatric exercise scientists have concentrated on measuring short-term power output by means of standardized protocol tests such as short-term cycling power tests, running tests or vertical jump tests. There is, however, no perfect test and, therefore, it is important to acknowledge the benefits and limitations of each testing method. Mass-related short-term power output was shown to increase dramatically during growth and development, whereas the corresponding increase in peak blood lactate was considerably lower. This suggests that the observed difference between children and adolescents during short-term power output testing may be related to neuromuscular factors, hormonal factors and improved motor coordination.

  17. Kansas squat test: a reliable indicator of short-term anaerobic power.

    PubMed

    Fry, Andrew C; Kudrna, Rebecca A; Falvo, Michael J; Bloomer, Richard J; Moore, Christopher A; Schilling, Brian K; Weiss, Lawrence W

    2014-03-01

    The purposes of this study were to establish stability reliability of a measure of lower-body anaerobic power, the Kansas squat test (KST), and to compare the KST with the commonly used Wingate anaerobic test (WAnT) for lower-body power. Fourteen resistance-trained men (mean ± SD; age = 24.2 ± 3.6 years) performed both the KST and the WAnT twice on separate occasions. The KST consisted of using an external dynamometer to measure mean repetition power while performing 15 repetitions of speed squats using 70% of 1 repetition maximum system mass (barbell + body mass), initiating each repetition at 6-second intervals. Repetition power, mean power for all 15 repetitions, and % fatigue for the KST were all reliable (intraclass correlation coefficient = 0.754-0.937; p ≤ 0.05). There were no differences between tests for the mean power for all repetitions or relative fatigue (p ≤ 0.05) and no significant differences between tests for any individual repetition (test × repetition interaction, p < 0.05). Although absolute values were different (p > 0.05), significant correlations were found between the KST and WAnT for mean (r = 0.752) and maximum (r = 0.775) test powers but not for relative fatigue (r = 0.174). Lactate (HLa) responses were greater for the WAnT compared with the KST. These data indicate that the KST is reliable for resistance-trained men, and that measures of maximum and mean test powers for the KST are highly correlated to those values for the WAnT, but fatigue rates and HLa responses were not correlated. It appears that the KST is a lifting-specific anaerobic power and power endurance test that emphasizes phosphagen metabolism and may be used to assess training-induced changes in lower-body power.

  18. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    ERIC Educational Resources Information Center

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  19. Effect of wrist cooling on aerobic and anaerobic performance in elite sportsmen.

    PubMed

    Krishnan, Anup; Singh, Krishan; Sharma, Deep; Upadhyay, Vivekanand; Singh, Amit

    2018-01-01

    Body cooling has been used to increase sporting performance and enhance recovery. Several studies have reported improvement in exercise capacities using forearm and hand cooling or only hand cooling. Wrist cooling has emerged as a portable light weight solution for precooling prior to sporting activity. The Astrand test for aerobic performance and the Wingate test for anaerobic performance are reliable and accurate tests for performance assessment. This study conducted on elite Indian athletes analyses the effects of wrist precooling on aerobic and anaerobic performance as tested by the Astrand test and the Wingate test before and after wrist precooling. 67 elite sportsmen were administered Wingate and Astrand test under standardised conditions with and without wrist precooling using a wrist cooling device (dhamaSPORT). Paired t -test was applied to study effect on aerobic [VO 2 (ml/min/kg)] and anaerobic performance [peak power (W/kg) and average power (W/kg)] and Cohen's d was used to calculate effect size of wrist precooling. After wrist precooling, significant increase of 0.22 ( p  = 0.014, 95% CI: 0.047, 0.398) in peak power (W/kg) and 0.22 ( p  < 0.0001, 95% CI: 0.142, 0.291) was observed in average power (W/kg). Although, an increase of 1.38 ( p  = 0.097, 95% CI: -0.225, 3.012) was observed in VO 2 (ml/min/kg), wrist precooling was not significantly effective in aerobic performance. Wrist cooling effect size was smaller in VO 2 (Cohen's d  = 0.21), peak power (Cohen's d  = 0.31) and it was larger in average power (Cohen's d  = 0.71). Results show wrist precooling significantly improves anaerobic than aerobic performance of elite sportsmen.

  20. Do isokinetic angular velocity and contraction types affect the predictors of different anaerobic power tests?

    PubMed

    Yapici, Aysegul; Findikoglu, Gulin; Dundar, Ugur

    2016-04-01

    The purpose of this study was to investigate the most important predictor isokinetic muscle strength determined by different angular velocities and contraction types (i.e. concentric and eccentric) for selected anaerobic power tests in volleyball players. Twenty male and ten female amateur volleyball players participated in this study. Selected anaerobic power tests included Wingate Anaerobic Test (WAnT), squat jump (SJ) and countermovement jump (CMJ). Peak torque values were obtained at 60, 120, 240˚/s for concentric contraction of quadriceps (Qconc) and Hamstring (Hconc) and at 60˚/s for eccentric contraction of quadriceps (Qecc) and Hconc. Moderate to good correlations (r:0.409 to r:0.887) were found between anaerobic tests and isokinetic data including peak torque and total work of both Hconc and Qconc at 60, 120, 240°/s and Qecc at 60°/s (P<0.05). Qconc measured at each of 60, 120, 240°/s was found to be the only significant predictor for anaerobic tests in linear regression models (P<0.05). Correlation coefficient s for Qconc increased with increasing velocity for each of the anaerobic tests. Correlation coefficient of Qconc was highest for CMJ followed by SJ and WAnT at the same angular velocity. As a distinctive feature, both Qecc and Hconc at 60˚/s were significantly predictors for CMJ and SJ. Qconc peak torque was the single significant predictor for WAnT, SJ and CMJ and strength of the relation increases with increasing angular velocity. However, both Qecc and Hconc were significant indicators for CMJ and SJ. Training with higher isokinetic angular velocities and with eccentric contraction is desirable in a training program that has a goal of improving anaerobic performance in volleyball players.

  1. Oxidative stress in response to aerobic and anaerobic power testing: influence of exercise training and carnitine supplementation.

    PubMed

    Bloomer, Richard J; Smith, Webb A

    2009-01-01

    The purpose of this study is to compare the oxidative stress response to aerobic and anaerobic power testing, and to determine the impact of exercise training with or without glycine propionyl-L-carnitine (GPLC) in attenuating the oxidative stress response. Thirty-two subjects were assigned (double blind) to placebo, GPLC-1 (1g PLC/d), GPLC-3 (3g PLC/d) for 8 weeks, plus aerobic exercise. Aerobic (graded exercise test: GXT) and anaerobic (Wingate cycle) power tests were performed before and following the intervention. Blood was taken before and immediately following exercise tests and analyzed for malondialdehyde (MDA), hydrogen peroxide (H2O2), and xanthine oxidase activity (XO). No interaction effects were noted. MDA was minimally effected by exercise but lower at rest for both GPLC groups following the intervention (p = 0.044). A time main effect was noted for H2O2 (p = 0.05) and XO (p = 0.003), with values increasing from pre- to postexercise. Both aerobic and anaerobic power testing increase oxidative stress to a similar extent. Exercise training plus GPLC can decrease resting MDA, but it has little impact on exercise-induced oxidative stress biomarkers.

  2. Running-based Anaerobic Sprint Test as a Procedure to Evaluate Anaerobic Power.

    PubMed

    Andrade, V L; Zagatto, A M; Kalva-Filho, C A; Mendes, O C; Gobatto, C A; Campos, E Z; Papoti, M

    2015-12-01

    The aim of this study was to evaluate the use of the running anaerobic sprint test (RAST) as a predictor of anaerobic capacity, compare it to the maximal accumulated oxygen deficit (MAOD) and to compare the RAST's parameters with the parameters of 30-s all-out tethered running on a treadmill. 39 (17.0±1.4 years) soccer players participated in this study. The participants underwent an incremental test, 10 submaximal efforts [50-95% of velocity correspondent to VO(2MAX) (vVO(2MAX))] and one supramaximal effort at 110% of vVO(2MAX) for the determination of MAOD. Furthermore, the athletes performed the RAST. In the second stage the 30-s all-out tethered running was performed on a treadmill (30-s all-out), and compared with RAST. No significant correlation was observed between MAOD and RAST parameters. However, significant correlations were found between the power of the fifth effort (P5) of RAST with peak and mean power of 30-s all-out (r=0.73 and 0.50; p<0.05, respectively). In conclusion, the parameters from RAST do not have an association with MAOD, suggesting that this method should not be used to evaluate anaerobic capacity. Although the correlations between RAST parameters with 30-s all-out do reinforce the RAST as an evaluation method of anaerobic metabolism, such as anaerobic power. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Prediction of anaerobic power values from an abbreviated WAnT protocol.

    PubMed

    Stickley, Christopher D; Hetzler, Ronald K; Kimura, Iris F

    2008-05-01

    The traditional 30-second Wingate anaerobic test (WAnT) is a widely used anaerobic power assessment protocol. An abbreviated protocol has been shown to decrease the mild to severe physical discomfort often associated with the WAnT. Therefore, the purpose of this study was to determine whether a 20-second WAnT protocol could be used to accurately predict power values of a standard 30-second WAnT. In 96 college females, anaerobic power variables were assessed using a standard 30-second WAnT protocol. Maximum power values as well as instantaneous power at 10, 15, and 20 seconds were recorded. Based on these results, stepwise regression analysis was performed to determine the accuracy with which mean power, minimum power, 30-second power, and percentage of fatigue for a standard 30-second WAnT could be predicted from values obtained during the first 20 seconds of testing. Mean power values showed the highest level of predictability (R2 = 0.99) from the 20-second values. Minimum power, 30-second power, and percentage of fatigue also showed high levels of predictability (R2 = 0.91, 0.84, and 0.84, respectively) using only values obtained during the first 20 seconds of the protocol. An abbreviated (20-second) WAnT protocol appears to effectively predict results of a standard 30-second WAnT in college-age females, allowing for comparison of data to published norms. A shortened test may allow for a decrease in unwanted side effects associated with the traditional WAnT protocol.

  4. Allometric Scaling of Wingate Anaerobic Power Test Scores in Women

    ERIC Educational Resources Information Center

    Hetzler, Ronald K.; Stickley, Christopher D.; Kimura, Iris F.

    2011-01-01

    In this study, we developed allometric exponents for scaling Wingate anaerobic test (WAnT) power data that are reflective in controlling for body mass (BM) and lean body mass (LBM) and established a normative WAnT data set for college-age women. One hundred women completed a standard WAnT. Allometric exponents and percentile ranks for peak (PP)…

  5. Acute effects of jaw clenching using a customized mouthguard on anaerobic ability and ventilatory flows.

    PubMed

    Morales, Jose; Buscà, Bernat; Solana-Tramunt, Mònica; Miró, Adrià

    2015-12-01

    The latest findings on the ergogenic effects of a dentistry-design, bite-aligning mouthpiece require additional research to assess its impact on anaerobic ability and ventilatory parameters. This paper was aimed at determining the ergogenic acute effects of wearing a custom-made mouthpiece on oral airflow dynamics, 30-s Wingate Anaerobic Test performance parameters. Twenty-eight healthy and physically-active male subjects (age: 24.50 ± 3.32, height: 181.34 ± 7.4, weight: 78.14 ± 8.21), were voluntarily studied. The subjects were first briefed on the test protocols, and then performed the 30s Wingate test and Spirometer test. The experimental trials were performed in a random counterbalanced order. We evaluate maximum expiratory volume (VEmax L min(-1)), mean power (W kg(-1)), peak power (W kg(-1)), time to peak (s), rate to fatigue (Ws(-1)) and lactate production (mMol L(-1)), rate of perceived exertion (RPE). There were significant differences between mouthguard and no-mouthguard conditions in mean power (W kg(-1)), peak power (W kg(-1)), time to peak (s), and rate to fatigue (Ws(-1)) for the 30-s Wingate Anaerobic Test. Significantly lower lactate production (mMol L(-1)) was observed, in mouthguard condition but no significant differences were found in RPE. In airflow dynamics, the VEmax L min(-1) was significantly higher when comparing the mouthguard and the no mouthguard conditions in both forced and unforced conditions. In conclusion, wearing a customized mouthguard improves anaerobic ability and increases forced expiratory volume. This study will help practitioners improve athlete's performance in anaerobic activities where high intensity action might provoke jaw-clenching, contributing in reductions of lactate and fatigue, and improving ventilatory parameters. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The development and reliability of a repeated anaerobic cycling test in female ice hockey players.

    PubMed

    Wilson, Kier; Snydmiller, Gary; Game, Alex; Quinney, Art; Bell, Gordon

    2010-02-01

    The purpose of this study was to develop and assess the reliability of a repeated anaerobic power cycling test designed to mimic the repeated sprinting nature of the sport of ice hockey. Nineteen female varsity ice hockey players (mean X +/- SD age, height and body mass = 21 +/- 2 yr, 166.6 +/- 6.3 cm and 62.3 +/- 7.3) completed 3 trials of a repeated anaerobic power test on a Monark cycle ergometer on different days. The test consisted of "all-out" cycling for 5 seconds separated by 10 seconds of low-intensity cycling, repeated 4 times. The relative load factor used for the resistance setting was equal to 0.095 kg per kilogram body mass. There was no significant difference between the peak 5-second power output (PO), mean PO, or the fatigue index (%) among the 3 different trials. The peak 5-second PO was 702.6 +/- 114.8 w and 11.3 +/- 1.1 w x kg, whereas the mean PO across the 4 repeats was 647.1 +/- 96.3 w and 10.4 +/- 1.0 w x kg averaged for the 3 different tests. The fatigue index averaged 17.8 +/- 6.5%. The intraclass correlation coefficient for peak 5-second, mean PO, and fatigue index was 0.82, 0.86, and 0.82, respectively. This study reports the methodology of a repeated anaerobic power cycling test that was reliable for the measurement of PO and calculated fatigue index in varsity women ice hockey players and can be used as a laboratory-based assessment of repeated anaerobic fitness.

  7. ANTHROPOMETRIC CHARACTERISTICS AND FUNCTIONAL CAPACITY OF ELITE ROWERS AND HANDBALL PLAYERS.

    PubMed

    Karaba Jakovljevic, Dea; Jovanovic, Gordana; Eric, Mirela; Klasnja, Aleksandar; Slavic, Danijel; Lukac, Damir

    2016-09-01

    Anthropometric and anaerobic profile of elite athletes are fundamental for the assessment of their respective performance. The present study was designed to evaluate the anthro- pornetric parameters, body composition and anaerobic characteristics of elite male handball players and rowers, and to compare them in relation to specific sport demands. The study group consisted of 41 elite national level athletes: 20 handball players (aged 23.7±3.72) and 21 rowers (aged 19.7±2.84). Anthropometric characteristics (body mass, body height, skinfold thickness, body circumferences), and body fat mass were evaluated, and Wingate anaerobic test for anaerobic power assessment Iwas applied. The significant differences were noted in chest-upper arm, waist and hip circumferences, and supraspinal and calf skinfolds between the two investigated groups. Rowers showed higher values of fat body mass (13.2±3.76 vs. 10.7±3.76%), but lower body mass index (22.0±1,92 vs. 25.7?2.31 kg/in12) compared to handball players. When analyzing the Wingate test parameters, significantly higher values of absolute anaerobic power (786±127 vs. 691±140 W), absolute explosive power in the handball players compared to the rowers were recorded ( 18±26.3 vs. 105±27.8 W/s), whi le rowers achieved higher relative anaerobic capacity (192±3 1.2 vs. 177±E20.8 J/ kg). Specific body composition and anthropometri- cal assessment as a part of morphological analysis should complement physiological profile of elite athletes. The analysis of the anaerobic performance shows that the handball players have greater alactic anaerobic and explosive power component, compared to the rowers in whom the anaerobic endurance and specific training have the greatest effect on the consumption of dominant metabolic substrate during the race.

  8. Physical Fitness as It Pertains to Sustained Military Operations

    DTIC Science & Technology

    1986-05-01

    Vogel and his colleagues (Vogel et al., 1983, Murphy et al., 1985) measured initial V02 max, and 2-mile run time, anaerobic power of the arms and...trial, and troop performance was evaluated by observers. Vogel and his co-workers found arm strength and arm anaerobic p,4er to decrease following...defense from infantry ground attack. Measurements of isometric, handgrip strength and upper and lower body anaerobic power (using the Wingate test) were

  9. Reduced anaerobic and aerobic performance in children with primary ciliary dyskinesia.

    PubMed

    Simsek, Senem; Inal-Ince, Deniz; Cakmak, Aslihan; Emiralioglu, Nagehan; Calik-Kutukcu, Ebru; Saglam, Melda; Vardar-Yagli, Naciye; Ozcelik, Hayriye Ugur; Sonbahar-Ulu, Hazal; Bozdemir-Ozel, Cemile; Kiper, Nural; Arikan, Hulya

    2018-05-01

    Primary ciliary dyskinesia (PCD) restricts lifestyle and increases morbidity. The aim of the study was to investigate anaerobic and aerobic performance in children with PCD and their healthy counterparts. Thirty-one children with PCD and 29 age- and sex-matched healthy subjects were studied. Pulmonary function, hand grip strength (HGS), quadriceps strength (QMS), physical activity, anaerobic capacity (muscle power sprint test), and aerobic performance (modified shuttle walk test (MSWT)) were determined. Pulmonary function, HGS, QMS, mean anaerobic power (MAP), and MSWT distance in PCD were significantly lower than those of healthy subjects (p < 0.05). In PCD, the MAP was significantly correlated with age, FEV 1 , and the mean kcal for 3 days (p < 0.05), and age was its independent predictor (p < 0.05). The MSWT distance was significantly related to gender and weight (p < 0.05), and gender was selected as its independent predictor (p < 0.05). In healthy controls, the MAP was significantly associated with age, gender, FVC, FEV 1 , HGS, QMS, and the mean kcal for three days (p < 0.05). The MSWT distance was significantly related to weight and body mass index in healthy group (p < 0.05). Anaerobic and aerobic performance is impaired in PCD from the early stages. Age determines anaerobic performance. Gender is the determinant of aerobic performance. Whether skeletal muscle characteristics and sex-related changes in body composition affect anaerobic and aerobic capacity in PCD children warrants further study. What is Known: • Exercise performance is determined by anaerobic and aerobic power. • Few studies have shown that PCD patients have lower aerobic performance which is associated with impaired lung function. What is New: • The present research indicated that both anaerobic and aerobic exercise capacity determined using field testing is impaired in PCD from the early stages. • Anaerobic capacity was found to be independently associated with age in PCD. Higher aerobic performance is independently associated with male gender.

  10. Physiological correlates of pulmonary function in children with cystic fibrosis.

    PubMed

    Wells, Greg D; Wilkes, Donna L; Schneiderman, Jane E; Thompson, Sara; Coates, Allan L; Ratjen, Felix

    2014-09-01

    Although peak aerobic capacity (VO(2peak)) has been linked to outcome in patients with cystic fibrosis (CF), measuring is time consuming, and requires expensive equipment and expertise that is not readily available in all centers. Other fitness parameters such as peak anaerobic power, measures of power and strength may be simpler to deliver in the clinic. The relationship between these measures and established outcomes such as forced expiratory volume in one second (FEV(1)) and peak aerobic power (VO(2peak)) in CF remains unclear. Therefore we evaluated (a) aerobic fitness, (b) anaerobic fitness, and (c) upper and lower body muscle strength to determine their relationship to FEV(1) and VO(2peak) in children with CF. Eighty-two patients (7-18 years) with CF (40 female) from the CF clinic at The Hospital for Sick Children in Toronto performed a maximal incremental cycling test to exhaustion. Anaerobic power (W) for 10 and 30 sec cycling trials as well as vertical jump (VJ) and hand grip strength (HG) were compared to FEV(1) and VO(2peak). Absolute VO(2peak) (R(2)  = 0.16, P < 0.001), anaerobic power (R(2)  = 0.21, P < 0.001), and hand grip strength (R(2)  = 0.10, P = 0.003) were significantly correlated to lung function whereas measures of explosive lower body strength (VJ) were not. Anaerobic power (R(2)  = 0.16, P = 0.001) and hand grip strength (R(2)  = 0.08, P = 0.01) were related to VO(2peak). Vertical jump was correlated with VO(2peak) (R(2)  = 0.29, P < 0.001) but not FEV(1). Simple fitness tests such as hand grip strength and anaerobic cycle tests may be useful indicators of lung health and fitness. © 2013 Wiley Periodicals, Inc.

  11. Physiological Interpretation of the Slope during an Isokinetic Fatigue Test.

    PubMed

    Bosquet, L; Gouadec, K; Berryman, N; Duclos, C; Gremeaux, V; Croisier, J-L

    2015-07-01

    To assess the relationship between selected measures (the slope and average performance) obtained during a high intensity isokinetic fatigue test of the knee (FAT) and relevant measures of anaerobic and aerobic capacities. 20 well-trained cyclists performed 3 randomly ordered sessions involving a FAT consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°.s(-1), a maximal continuous graded exercise test (GXT), and a Wingate anaerobic test (WAnT). The slope calculated from peak torque (PT) and total work (TW) of knee extensors was highly associated to maximal PT (r=-0.86) and maximal TW (r=-0.87) measured during FAT, and moderately associated to peak power output measured during the WAnT (r=-0.64 to -0.71). Average PT and average TW were highly associated to maximal PT (r=0.93) and maximal TW (r=0.96), to mean power output measured during WAnT (r=0.83-0.90) and moderately associated to maximal oxygen uptake (0.58-0.67). In conclusion, the slope is mainly determined by maximal anaerobic power, while average performance is a composite measure depending on both aerobic and anaerobic energy systems according to proportions that are determined by the duration of the test. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Anaerobic performances of sedentary and trained subjects.

    PubMed

    Serresse, O; Ama, P F; Simoneau, J A; Lortie, G; Bouchard, C; Boulay, M R

    1989-03-01

    The objective of this report was to compare the performance of sedentary individuals, physical education students, and athletes of various disciplines in 10 s and 90 s maximal cycle ergometer tests. The 10 s power was the highest power output in one second from the 10 s test, while capacities were defined as the total work output during the best 10 s trial and the 90 s test. ANOVA and Duncan multiple range test indicated that the mean values of the 10 S power and capacity and the 90 S capacity tests were significantly higher in sprinter than in sedentary groups. Sprinters performed significantly better than marathon runners only in the 10 s capacity and power. Bodybuilders and sedentary subjects had similar results in the 90 s capacity test. Mean performance values per kilogram of body weight in sedentary females reached about 60% of sedentary males while marathon runners, physical education students and sprinter females reached about 80% of the male performances for the three indicators. When expressed per kilogram of fat-free mass, females reached a higher proportion of the male values for all performances. These results indicate that: a) there are differences for the power and capacity measured in predominantly anaerobic tests between athletes from different disciplines and sedentary individuals, and b) gender differences exist for these anaerobic performance indicators, but they appear attenuated in trained subjects.

  13. Active dehydration impairs upper and lower body anaerobic muscular power.

    PubMed

    Jones, Leon C; Cleary, Michelle A; Lopez, Rebecca M; Zuri, Ron E; Lopez, Richard

    2008-03-01

    We examined the effects of active dehydration by exercise in a hot, humid environment on anaerobic muscular power using a test-retest (euhydrated and dehydrated) design. Seven subjects (age, 27.1 +/- 4.6 years; mass, 86.4 +/- 9.5 kg) performed upper and lower body Wingate anaerobic tests prior to and after a 1.5-hour recovery from a heat stress trial of treadmill exercise in a hot, humid environment (33.1 +/- 3.1C = 55.1 +/- 8.9% relative humidity) until a 3.1 +/- 0.3% body mass loss was achieved. Dehydration was confirmed by a significant body mass loss (P < 0.001), urine color increase (P = 0.004), and urine specific gravity increase (P = 0.041). Motivation ratings were not significantly different (P = 0.059), and fatigue severity was significantly (P = 0.009) increased 70% in the dehydrated compared to the euhydrated condition. Compared to the euhydrated condition, the dehydrated condition mean power was significantly (P = 0.014) decreased 7.17% in the upper body and 19.20% in the lower body. Compared to the euhydrated condition, the dehydrated condition peak power was significantly (P = 0.013) decreased 14.48% in the upper body and 18.36% in the lower body. No significant differences between the euhydrated and dehydrated conditions were found for decrease in power output (P = 0.219, power = 0.213). Our findings suggest that dehydration of 2.9% body mass decreases the ability to generate upper and lower body anaerobic power. Coaches and athletes must understand that sports performance requiring anaerobic strength and power can be impaired by inadequate hydration and may contribute to increased susceptibility to musculoskeletal injury.

  14. Test results for fuel cell operation on anaerobic digester gas

    NASA Astrophysics Data System (ADS)

    Spiegel, R. J.; Preston, J. L.

    EPA, in conjunction with ONSI, embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the process of treating sewage anaerobically to reduce solids. ADG is primarily comprised of methane (57-66%), carbon dioxide (33-39%), nitrogen (1-10%), and a small amount of oxygen (<0.5%). Additionally, ADG contains trace amounts of fuel cell catalyst contaminants consisting of sulfur-bearing compounds (principally hydrogen sulfide) and halogen compounds (chlorides). The project has addressed two major issues: development of a cleanup system to remove fuel cell contaminants from the gas and testing/assessing of a modified ONSI PC25 C fuel cell power plant operating on the cleaned, but dilute, ADG. Results to date demonstrate that the ADG fuel cell power plant can, depending on the energy content of the gas, produce electrical output levels close to full power (200 kW) with measured air emissions comparable to those obtained by a natural gas fuel cell. The cleanup system results show that the hydrogen sulfide levels are reduced to below 10 ppbv and halides to approximately 30 ppbv.

  15. Comparison of two anaerobic water polo-specific tests with the Wingate test.

    PubMed

    Bampouras, Theodoros M; Marrin, Kelly

    2009-01-01

    The purpose of the current study was to compare 2 water polo-specific tests-the 14 x 25-m swims (SWIM) and the 30-second crossbar jumps (30CJ)-with a laboratory-based test of anaerobic power, the Wingate Anaerobic Test (WAnT). Thirteen elite women's water polo players (mean +/- SD: age 22.0 +/- 4.4 years, height 168.7 +/- 7.9 cm, body mass 65.9 +/- 6.1 kg, body fat 23.6 +/- 3.5 %, maximum oxygen uptake 51.4 +/- 4.5 mlxkgxmin) participated in the study. The SWIM involved 14 repeated "all-out" sprints every 30 seconds. Swimming time was recorded, and sprint velocity, mean velocity (Vmean), and the gradient of the linear regression equation (GRADIENT) were calculated. The 30CJ involved repeated in-water water polo jumps and touching the goal crossbar with both hands. The number of touches in 30 seconds was recorded. Additionally, the subjects completed a 30-second WAnT, and mean power (Mp) and fatigue index (FI) were calculated. Kendall tau (tau) rank correlation was used to examine for correlation between ranks. Significance level was set at p

  16. The ventilatory anaerobic threshold is related to, but is lower than, the critical power, but does not explain exercise tolerance at this workrate.

    PubMed

    Okudan, N; Gökbel, H

    2006-03-01

    The aim of the present study was to investigate the relationships between critical power (CP), maximal aerobic power and the anaerobic threshold and whether exercise time to exhaustion and work at the CP can be used as an index in the determination of endurance. An incremental maximal cycle exercise test was performed on 30 untrained males aged 18-22 years. Lactate analysis was carried out on capillary blood samples at every 2 minutes. From gas exchange parameters and heart rate and lactate values, ventilatory anaerobic thresholds, heart rate deflection point and the onset of blood lactate accumulation were calculated. CP was determined with linear work-time method using 3 loads. The subjects exercised until they could no longer maintain a cadence above 24 rpm at their CP and exercise time to exhaustion was determined. CP was lower than the power output corresponding to VO2max, higher than the power outputs corresponding to anaerobic threshold. CP was correlated with VO2max and anaerobic threshold. Exercise time to exhaustion and work at CP were not correlated with VO2max and anaerobic threshold. Because of the correlations of the CP with VO2max and anaerobic threshold and no correlation of exercise time to exhaustion and work at the CP with these parameters, we conclude that exercise time to exhaustion and work at the CP cannot be used as an index in the determination of endurance.

  17. The influence of ambient temperature on power at anaerobic threshold determined based on blood lactate concentration and myoelectric signals.

    PubMed

    Tyka, Aleksander; Pałka, Tomasz; Tyka, Anna; Cisoń, Tomasz; Szyguła, Zbigniew

    2009-01-01

    To compare the mechanical power and physiological parameters in males at the lactate (LAAT) and integrated electromyographic (IEMGAT) anaerobic thresholds during exercise testing at 23 degrees C, 31 degrees C and 37 degrees C. Fifteen men aged 21.9+/-1.80 years performed an incremental exercise test on a cycle ergometer at pedal frequency of 60 rpm. The test began at the power output of 120 W which was increased by 30 W every 3 min. Heart rate, oxygen uptake, carbon dioxide in expired air and minute ventilation were monitored. Venous blood samples were collected at 30 s before termination of each 3-min stage of test to determine the lactate anaerobic threshold. IEMGAT for vastus lateralis (VL) and rectus femoris (RF) muscles were regarded as the inflection point at which a non-linear increase in IEMGAT occurred. IEMGAT for VL and RF were similar for all the three temperatures. IEMGAT (VL and RF) correlated closely with LAAT at ambient temperatures of 23 degrees C (r = 0.91), 31 degrees C (r = 0.96) and 37 degrees C (r = 0.97). Repeated measures analysis of variance (ANOVA) revealed that the mechanical power at LAAT and IEMGAT was higher at 23 degrees C (202+/-26.5 W vs. 205+/-22.9 W) than at 31 degrees C (186+/-20.2 W vs. 186.2+/-20.2 W) and 37 degrees C (175.5+/-25.2 W vs. 175.3+/-20.0 W) for LAAT and IEMGAT respectively (p < 0.01). Higher ambient temperature induced a decrease in the mechanical power at which the anaerobic threshold occurred. The high correlation between LAAT and IEMGAT (r = 0.91-0.97) indicated that IEMGAT can be used as a practical and reliable, non-invasive method for assessment of the anaerobic threshold.

  18. Effects of High-Intensity Training on Anaerobic and Aerobic Contributions to Total Energy Release During Repeated Supramaximal Exercise in Obese Adults.

    PubMed

    Jabbour, Georges; Iancu, Horia-Daniel; Paulin, Anne

    Studying relative anaerobic and aerobic metabolism contributions to total energy release during exercise may be valuable in understanding exercise energetic demands and the energetic adaptations that occur in response to acute or chronic exercise in obese adults. The aim of the present study is to evaluate the effects of 6 weeks of high-intensity training (HIT) on relative anaerobic and aerobic contributions to total energy release and on peak power output during repeated supramaximal cycling exercises (SCE) in obese adults. Twenty-four obese adults (body mass index = ± 33 kg.m -2 ) were randomized into a control group ( n  = 12) and an HIT group ( n  = 12). Accumulated oxygen deficits (ml.min -1 ) and anaerobic and aerobic contributions (%) were measured in all groups before and after training via repeated SCE. In addition, the peak power output performed during SCE was determined using the force-velocity test. Before HIT, anaerobic contributions to repeated SCE did not differ between the groups and decreased significantly during the third and fourth repetitions. After HIT, anaerobic contributions increased significantly in the HIT group (+11 %, p  < 0.01) and were significantly higher than those of the control group ( p  < 0.01). Moreover, the peak power obtained during SCE increased significantly in the HIT group (+110 W.kg -1 , p  < 0.01) and correlated positively with increases in anaerobic contributions ( r  = 0.9, p  < 0.01). In obese adults, HIT increased anaerobic contributions to energy release which were associated with peak power enhancement in response to repeated SCE. Consequently, HIT may be an appropriate approach for improving energy contributions and muscle power among obese adults.

  19. Influence of Ramadan Fasting on Anaerobic Performance and Recovery Following Short time High Intensity Exercise.

    PubMed

    Karli, Umid; Guvenc, Alpay; Aslan, Alper; Hazir, Tahir; Acikada, Caner

    2007-01-01

    The aim of this study was to investigate the effects of Ramadan fasting on anaerobic power and capacity and the removal rate of lactate after short time high intensity exercise in power athletes. Ten male elite power athletes (2 wrestlers, 7 sprinters and 1 thrower, aged 20-24 yr, mean age 22.30 ± 1.25 yr) participated in this study. The subjects were tested three times [3 days before the beginning of Ramadan (Pre-RF), the last 3 days of Ramadan (End-RF) and the last 3 days of the 4(th) week after the end of Ramadan (After-RF)]. Anaerobic power and capacity were measured by using the Wingate Anaerobic Test (WAnT) at Pre-RF, End-RF and After- RF. Capillary blood samples for lactate analyses and heart rate recordings were taken at rest, immediately after WAnT and throughout the recovery period. Repeated measures of ANOVA indicated that there were no significant changes in body weight, body mass index, fat free mass, percentage of body fat, daily sleeping time and daily caloric intake associated with Ramadan fasting. No significant changes were found in total body water either, but urinary density measured at End-RF was significantly higher than After-RF. Similarity among peak HR and peak LA values at Pre-RF, End- RF and After-RF demonstrated that cardiovascular and metabolic stress caused by WAnT was not affected by Ramadan fasting. In addition, no influence of Ramadan fasting on anaerobic power and capacity and removal rate of LA from blood following high intensity exercise was observed. The results of this study revealed that if strength-power training is performed regularly and daily food intake, body fluid balance and daily sleeping time are maintained as before Ramadan, Ramadan fasting will not have adverse effects on body composition, anaerobic power and capacity, and LA metabolism during and after high intensity exercise in power athletes. Key pointsNo significant changes were assessed on body composition, daily sleeping time and caloric intake, and body fluid balance in regularly trained power athletes during Ramadan fasting.Ramadan fasting has no adverse effect on power outputs of short time high intensity exercise.No influence of Ramadan fasting on LA metabolism during high intensity exercise and passive recovery in regularly trained power athletes.

  20. Variable resistance all-out test to generate accumulated oxygen deficit and predict anaerobic capacity.

    PubMed

    Gastin, P B; Lawson, D L

    1994-01-01

    A supramaximal variable resistance test over varying time intervals was evaluated as an instrument for the assessment of a number of anaerobic parameters, including the accumulated oxygen deficit (AOD). Eight active men [age, 22 +/- 1 (SEM 1) years, peak oxygen uptake, 53.1 (SEM 2.1) ml x kg-1 x min-1] completed three randomly ordered all-out sprints of 45-, 60- and 90-s duration. Two incremental pretests consisting of three 5-min stages at power outputs of 45, 135, 225 W and 90, 180, 270 W were performed to establish individual efficiency relationships [r = 0.996 (SEE 1.1) ml x kg-1 x min-1]. These relationships were used to estimate energy demand (millilitres per kilogram of oxygen equivalents in 15-s time intervals) during the supramaximal tests. The AOD for the 45 [47.6 (SEM 1.5) ml x kg-1], 60 [49.0 (SEM 1.8) ml x kg-1] and 90 s [49.6 (SEM 1.7) ml x kg-1] tests were significantly different only for the 45 and 90-s tests. Evaluation of the 90-s test indicated that maximal or near-maximal (98%) anaerobic energy release was achieved in 60 s, with the AOD beginning to plateau after this time. No significant differences among tests were found for peak power, time to peak power and peak pedalling rate. Differences in mean power, total work and relative power decrement were related to the length of the test.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. The effect of different calculation methods of flywheel parameters on the Wingate Anaerobic Test.

    PubMed

    Coleman, S G; Hale, T

    1998-08-01

    Researchers compared different methods of calculating kinetic parameters of friction-braked cycle ergometers, and the subsequent effects on calculating power outputs in the Wingate Anaerobic Test (WAnT). Three methods of determining flywheel moment of inertia and frictional torque were investigated, requiring "run-down" tests and segmental geometry. Parameters were used to calculate corrected power outputs from 10 males in a 30-s WAnT against a load related to body mass (0.075 kg.kg-1). Wingate Indices of maximum (5 s) power, work, and fatigue index were also compared. Significant differences were found between uncorrected and corrected power outputs and between correction methods (p < .05). The same finding was evident for all Wingate Indices (p < .05). Results suggest that WAnT must be corrected to give true power outputs and that choosing an appropriate correction calculation is important. Determining flywheel moment of inertia and frictional torque using unloaded run-down tests is recommended.

  2. The Relationship Between Body Composition and Anaerobic Performance of Elite Young Wrestlers

    PubMed Central

    Vardar, Selma Arzu; Tezel, Selin; Öztürk, Levent; Kaya, Oktay

    2007-01-01

    The purpose of the present study was to investigate the relationship between body composition and anaerobic performance in young elite wrestlers. Method: Eight female (age = 16.2 ± 1.1 yrs) and 8 male (age = 17.3 ± 0.9 yrs) wrestlers from the Turkish cadet and junior national team participated in this study. Fat free mass (FFM) and percent fat mass (%FM) were carried out through electric bioimpedance. Anaerobic performance was assessed by the Wingate test (load was calculated as 0.090 kg x.kg-1 body mass). FFM was greater in male wrestlers [65.4 ± 12.3 (kg)] than female wrestlers (45.1 ± 4.6 (kg) p < 0.01). %FM was lower in male wrestlers (9.7 ± 6.3) than female wrestlers (18.5 ± 2.8; p < 0.01). Peak power was significantly higher in male wrestlers than female wrestlers (8.5 ± 1.0 W·kg-1 vs. 6.8 ± 0.6 W·kg-1; p < 0.01). Mean power was significantly correlated with FFM in both genders (r = 0.73 p < 0.05 in female; r= 0.90 p < 0.05 in male). No relationship was obtained between anaerobic parameters and %FM. In conclusion, our result demonstrated no association between anaerobic parameters and %FM. Wrestlers and their coaches should take into account FFM rather than %FM for higher anaerobic performance. Key points Mean power and fat free mass association was obtained from both genders. Anaerobic performance parameters obtained from Wingate Test were positively associated with fat free mass but not % fat mass in elite young wrestlers. % FM values were 18.5 in young female wrestlers, and it was 9.7 in male wrestlers. PMID:24198701

  3. The effects of five weeks of kickboxing training on physical fitness

    PubMed Central

    Ouergui, Ibrahim; Hssin, Nizar; Haddad, Monoem; Padulo, Johnny; Franchini, Emerson; Gmada, Nabil; Bouhlel, Ezzedine

    2014-01-01

    Summary Aim: the purpose of this study was to examine the effect of kickboxing training on physical fitness. Methods: 30 subjects were randomized into a kickboxing-group (n=15) and control group (n=15). Each group trained approximately 1-hour per day, three-times per a week during five weeks. Muscle-power (upper-body: bench-press-test, medicine-ball-test; lower-body: squat-jump and counter-movement-jump-test), flexibility, speed and agility, aerobic (progressive maximal exercise test), anaerobic fitness (Wingate test) and body composition were assessed before and after the training period. Results: the kickboxing group showed significant improvement (p < 0.05) in upper-body muscle power, aerobic power, anaerobic fitness, flexibility, speed and agility after training whereas body composition, squat jump and counter movement jump (height, power and velocity components) did not change for both groups. Conclusion: kickboxing-practice was effective to change many physical variables. Thus, this activity can be useful for enhancing physical fitness, but complementary activities and/or nutritional interventions should be necessary. PMID:25332919

  4. Validity, Reliability, and Performance Determinants of a New Job-Specific Anaerobic Work Capacity Test for the Norwegian Navy Special Operations Command.

    PubMed

    Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls

    2016-02-01

    Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants of performance.

  5. Development of a specific anaerobic field test for aerobic gymnastics.

    PubMed

    Alves, Christiano Robles Rodrigues; Borelli, Marcello Tadeu Caetano; Paineli, Vitor de Salles; Azevedo, Rafael de Almeida; Borelli, Claudia Cristine Gomes; Lancha Junior, Antônio Herbert; Gualano, Bruno; Artioli, Guilherme Giannini

    2015-01-01

    The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8), the reliability (Study II, n=10) and the sensitivity (Study III, n=30) of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04) and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03). Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002), lower-body Wingate Test (p = 0.021) and a simulated competition (p = 0.007). In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen's d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s). Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p < 0.001), showing an improvement in SAGAT performance after a specific Aerobic Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings.

  6. Development of a Specific Anaerobic Field Test for Aerobic Gymnastics

    PubMed Central

    Paineli, Vitor de Salles; Azevedo, Rafael de Almeida; Borelli, Claudia Cristine Gomes; Lancha Junior, Antônio Herbert; Gualano, Bruno; Artioli, Guilherme Giannini

    2015-01-01

    The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8), the reliability (Study II, n=10) and the sensitivity (Study III, n=30) of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04) and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03). Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002), lower-body Wingate Test (p = 0.021) and a simulated competition (p = 0.007). In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen’s d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s). Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p < 0.001), showing an improvement in SAGAT performance after a specific Aerobic Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings. PMID:25876039

  7. Influence of upper-body external loading on anaerobic exercise performance.

    PubMed

    Inacio, Mario; Dipietro, Loretta; Visek, Amanda J; Miller, Todd A

    2011-04-01

    The purpose of this study was to assess the threshold where simulated adipose tissue weight gain significantly affects performance in common anaerobic tasks and determine whether differences exist between men and women. Forty-six subjects (men = 21; women = 25) were tested for vertical jump, 20- and 40-yd dash, and 20-yd shuttle tests under 6 different loading conditions (0, 2, 4, 6, 8, and 10% of added body weight). Results were compared to each subject's baseline values (0% loading condition). Results demonstrate significant decrements in performance, starting at the 2% loading condition, for both genders, in every performance test (p < 0.05). On average, subjects jumped 4.91 ± 0.29 to 9.83 ± 0.30 cm less, increased agility test times from 5.49 ± 0.56 to 5.86 ± 0.61 seconds, and increased sprint times from 7.80 ± 0.96 to 8.39 ± 1.07 seconds (2-10%, respectively; p < 0.05). When lower-body power was corrected for total body mass, men exerted significantly more power than women did in every loading condition. Conversely, when lower-body power was corrected for lean body mass, men exerted significantly more power than did women only at the 2% loading condition. This study demonstrates that for the specific anaerobic performance tests performed, increases in external loading as low as 2% of body weight results in significant decreases in performance. Moreover, for these specific tests, men and women tend to express the same threshold in performance decrements.

  8. On the kinetics of anaerobic power

    PubMed Central

    2012-01-01

    Background This study investigated two different mathematical models for the kinetics of anaerobic power. Model 1 assumes that the work power is linear with the work rate, while Model 2 assumes a linear relationship between the alactic anaerobic power and the rate of change of the aerobic power. In order to test these models, a cross country skier ran with poles on a treadmill at different exercise intensities. The aerobic power, based on the measured oxygen uptake, was used as input to the models, whereas the simulated blood lactate concentration was compared with experimental results. Thereafter, the metabolic rate from phosphocreatine break down was calculated theoretically. Finally, the models were used to compare phosphocreatine break down during continuous and interval exercises. Results Good similarity was found between experimental and simulated blood lactate concentration during steady state exercise intensities. The measured blood lactate concentrations were lower than simulated for intensities above the lactate threshold, but higher than simulated during recovery after high intensity exercise when the simulated lactate concentration was averaged over the whole lactate space. This fit was improved when the simulated lactate concentration was separated into two compartments; muscles + internal organs and blood. Model 2 gave a better behavior of alactic energy than Model 1 when compared against invasive measurements presented in the literature. During continuous exercise, Model 2 showed that the alactic energy storage decreased with time, whereas Model 1 showed a minimum value when steady state aerobic conditions were achieved. During interval exercise the two models showed similar patterns of alactic energy. Conclusions The current study provides useful insight on the kinetics of anaerobic power. Overall, our data indicate that blood lactate levels can be accurately modeled during steady state, and suggests a linear relationship between the alactic anaerobic power and the rate of change of the aerobic power. PMID:22830586

  9. Lactate Accumulation for Runners and Non-Runners during Various Exercise Tests,

    DTIC Science & Technology

    1980-08-21

    individual reaches a point at which lactate begins to increase exponentially in the blood. Anaerobic threshold (AT) and lactate turning point (LTP) are terms...Workloads were assigned based upon a previous assessment of the subject’s anaerobic threshold , however, there was no indication of the individual’s...Vodak, 3.H. Wilmore, J. Vodak and P Kurtz. Anaerobic threshold and maximal aerobic power for three modes of exercise. J. Appl. Physiol. 41(4):544-550

  10. Wingate anaerobic test reference values for male power athletes.

    PubMed

    Coppin, Erin; Heath, Edward M; Bressel, Eadric; Wagner, Dale R

    2012-09-01

    The aim of this study was to develop reference values for the Wingate Anaerobic Test (WAnT) for peak power (PP), mean power (MP), and fatigue index (FI) in NCAA Division IA male athletes. Seventy-seven athletes (age 20.8±1.8 y, mass 84.4±9.4 kg, height 183.9±6.2 cm) participating in American football (n=52) and track and field (n=25) performed a 30-s WAnT resisted at 0.085 kp/kg body mass (BM). Absolute mean (±SD) values for PP and MP were 1084.2±137.0 and 777.1±80.9 W, respectively, whereas values normalized to BM were 12.9±1.5 and 9.3±0.9 W/kg BM, respectively. Mean FI values were 49.1%±8.4%. PP outputs>13.6, 12.4-13.6, and <12.4 W/kg BM were classified as high, medium, and low, respectively. MP outputs>9.8, 9.0-9.8, and <9.0 W/kg BM were classified as high, medium, and low, respectively. The reference values developed in this study can be used in various athletic training and research programs to more accurately assess athletes' anaerobic fitness and to monitor changes resulting from anaerobic training.

  11. Comparison of body composition, heart rate variability, aerobic and anaerobic performance between competitive cyclists and triathletes

    PubMed Central

    Arslan, Erşan; Aras, Dicle

    2016-01-01

    [Purpose] The aim of this study was to compare the body composition, heart rate variability, and aerobic and anaerobic performance between competitive cyclists and triathletes. [Subjects] Six cyclists and eight triathletes with experience in competitions voluntarily participated in this study. [Methods] The subjects’ body composition was measured with an anthropometric tape and skinfold caliper. Maximal oxygen consumption and maximum heart rate were determined using the incremental treadmill test. Heart rate variability was measured by 7 min electrocardiographic recording. The Wingate test was conducted to determine anaerobic physical performance. [Results] There were significant differences in minimum power and relative minimum power between the triathletes and cyclists. Anthropometric characteristics and heart rate variability responses were similar among the triathletes and cyclists. However, triathletes had higher maximal oxygen consumption and lower resting heart rates. This study demonstrated that athletes in both sports have similar body composition and aerobic performance characteristics. PMID:27190476

  12. The relation between knee muscle strength and performance tests in orienteering athletes.

    PubMed

    Çinar-Medeni, Özge; Colakoglu, Fatma F; Yüce, Koray; Ipekoğlu, Gökhan; Baltaci, Gul

    2016-11-01

    The aim of this study was to analyze the effect of knee muscle strength on performance tests in orienteers. Thirty-seven orienteers were voluntarily included in this study. Isokinetic knee flexor and extensor muscles' strength was assessed at 120°/s velocity for both "dominant leg" (DL) and "non-dominant leg" (NDL). "Single-legged hop test" (SLHT), "flamingo balance test" (FBT), "star excursion balance test" (SEBT), vertical jump-and-reach test (for anaerobic power), T-drill test and 20-meter shuttle run test (for aerobic power) were carried out. Correlation and regression analyses were performed on the data. VO2max levels showed moderate correlations with DL's "flexor peak torque" (FPT) and NDL's "extensor peak torque" (EPT) and FPT values respectively (r=0.49, r=0.38, r=0.58). FPT of NDL was a predictor of VO2max level (R2=0.33). Anaerobic power has a relationship with EPT of NDL (r=0.43) and T-drill test with EPT and FPT values of both DL and NDL respectively (r=-0.35, r=-0.63, r=-0.53, r=-0.58). EPT of NDL was a predictor for anaerobic power (R2=0.19) and FPT of DL for agility (R2=0.40). Nonparametric linear regression results showed that EPT is a predictor in DL (median slope=-0.71, P=0.01), and FPT in NDL (median slope=-0.90, P=0.006) for FBT. FPT was a predictor of SEBT scores for both legs (0.13

  13. Fatigue in repeated-sprint exercise is related to muscle power factors and reduced neuromuscular activity.

    PubMed

    Mendez-Villanueva, Alberto; Hamer, Peter; Bishop, David

    2008-07-01

    The purpose of this study was (1) to determine the relationship between each individual's anaerobic power reserve (APR) [i.e., the difference between the maximum anaerobic (Pana) and aerobic power (Paer)] and fatigability during repeated-sprint exercise and (2) to examine the acute effects of repeated sprints on neuromuscular activity, as evidenced by changes in the surface electromyogram (EMG) signals. Eight healthy males carried out tests to determine Pana (defined as the highest power output attained during a 6-s cycling sprint), Paer (defined as the highest power output achieved during a progressive, discontinuous cycling test to failure) and a repeated cycling sprint test (10 x 6-s max sprints with 30 s rest). Peak power output (PPO) and mean power output (MPO) were calculated for each maximal 6-s cycling bout. Root mean square (RMS) was utilized to quantify EMG activity from the vastus lateralis (VL) muscle of the right leg. Over the ten sprints, PPO and MPO decreased by 24.6 and 28.3% from the maximal value (i.e., sprint 1), respectively. Fatigue index during repeated sprints was significantly correlated with APR (R = 0.87; P < 0.05). RMS values decreased over the ten sprints by 14.6% (+/-6.3%). There was a strong linear relationship (R2 = 0.97; P < 0.05) between the changes in MPO and EMG RMS from the vastus lateralis muscle during the ten sprints. The individual advantage in fatigue-resistance when performing a repeated sprint task was related with a lower anaerobic power reserve. Additionally, a suboptimal net motor unit activity might also impair the ability to repeatedly generate maximum power outputs.

  14. What Performance Characteristics Determine Elite Versus Nonelite Athletes in the Same Sport?

    PubMed Central

    Lorenz, Daniel S.; Reiman, Michael P.; Lehecka, B.J.; Naylor, Andrew

    2013-01-01

    Context: There are significant data comparing elite and nonelite athletes in anaerobic field and court sports as well as endurance sports. This review delineates specific performance characteristics in the elite athlete and may help guide rehabilitation. Evidence Acquisition: A Medline search from April 1982 to April 2012 was undertaken for articles written in English. Additional references were accrued from reference lists of research articles. Results: In the anaerobic athlete, maximal power production was consistently correlated to elite performance. Elite performance in the endurance athlete is more ambiguous, however, and appears to be related to the dependent variable investigated in each individual study. Conclusion: In anaerobic field and court sport athletes, maximal power output is most predictive of elite performance. In the endurance athlete, however, it is not as clear. Elite endurance athletes consistently test higher than nonelite athletes in running economy, anaerobic threshold, and VO2max. PMID:24427430

  15. High-intensity interval training and athletic performance in Taekwondo athletes.

    PubMed

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (P<0.05), relative peak power (P<0.05), and mean power (P<0.05) were observed only in HIIT group compared to HICR group. A greater improvement of aerobic capacity was observed in HIIT group (8.8%) compared to the HICR group (1.7%). In relation to physical fitness, the HIIT group improved in the vertical jump while the HICR group did not change. Both the HIIT and HICR groups showed greater improvements in T-test and sit-ups during the intervention period. This study shows the effectiveness of eleven sessions of HIIT in producing significant improvements in anaerobic capacity relevant to successful Taekwondo competition performance in collegiate Taekwondo athletes. This could inform the future planning of Taekwondo athletes' pre-competition training, specifically the influence of training intensity on anaerobic capacity.

  16. Poor anaerobic power/capability and static balance predicted prospective musculoskeletal injuries among Soldiers of the 101st Airborne (Air Assault) Division.

    PubMed

    Nagai, Takashi; Lovalekar, Mita; Wohleber, Meleesa F; Perlsweig, Katherine A; Wirt, Michael D; Beals, Kim

    2017-11-01

    Musculoskeletal injuries have negatively impacted tactical readiness. The identification of prospective and modifiable risk factors of preventable musculoskeletal injuries can guide specific injury prevention strategies for Soldiers and health care providers. To analyze physiological and neuromuscular characteristics as predictors of preventable musculoskeletal injuries. Prospective-cohort study. A total of 491 Soldiers were enrolled and participated in the baseline laboratory testing, including body composition, aerobic capacity, anaerobic power/capacity, muscular strength, flexibility, static balance, and landing biomechanics. After reviewing their medical charts, 275 male Soldiers who met the criteria were divided into two groups: with injuries (INJ) and no injuries (NOI). Simple and multiple logistic regression analyses were used to calculate the odds ratio (OR) and significant predictors of musculoskeletal injuries (p<0.05). The final multiple logistic regression model included the static balance with eyes-closed and peak anaerobic power as predictors of future injuries (p<0.001). The current results highlighted the importance of anaerobic power/capacity and static balance. High intensity training and balance exercise should be incorporated in their physical training as countermeasures. Copyright © 2017 Sports Medicine Australia. All rights reserved.

  17. Lower skin temperature decreases maximal cycling performance.

    PubMed

    Imai, Daiki; Okazaki, Kazunobu; Matsumura, Shinya; Suzuki, Takashi; Miyazawa, Taiki; Suzuki, Akina; Takeda, Ryosuke; Hamamoto, Takeshi; Zako, Tetsuo; Kawabata, Takashi; Miyagawa, Toshiaki

    2011-12-01

    It is known that external cooling of body regions involved in exercise, prior to exercise, decreases anaerobic performance. However, there have been no studies reporting the effects of whole body skin surface cooling before exercise on maximal anaerobic capacity. In order to clarify the effects, we compared power output during the Wingate anaerobic test between preconditioning by exposure to temperature 10 degrees C and 25 degrees C. Eight healthy males carried out the Wingate test for 30 seconds, after pre-conditioning for 60 minutes using a perfusion suit with water at a temperature of 10 degrees C or 25 degrees C. We evaluated the peak power (PP) and peak power slope (PS) of the power output. Mean skin temperature (T(sk)) at 60 minutes of pre-conditioning in the 10 degrees C trial was significantly lower than in the 25 degrees C trial (p < 0.05). PP and also PS were significantly lower in the 10 degrees C trial than in the 25 degrees C trial. Changes (Δ) in PP between the 10 degrees C trial and the 25 degrees C trial were strongly correlated with ΔT(sk) and Δ in thigh and leg skin temperature (ΔT(thigh) and ΔT(leg), respectively), whereas ΔPS was strongly correlated with ΔT(sk), but not with ΔT(thigh) and ΔT(leg). Whole body skin surface cooling prior to exercise restricts anaerobic capacity, especially in the initial phase of exercise.

  18. Validity and Reliability of the 30-s Continuous Jump for Anaerobic Power and Capacity Assessment in Combat Sport

    PubMed Central

    Čular, Drazen; Ivančev, Vladimir; Zagatto, Alessandro M.; Milić, Mirjana; Beslija, Tea; Sellami, Maha; Padulo, Johnny

    2018-01-01

    Cycling test such Wingate anaerobic test (WAnT) is used to measure anaerobic power (AP), but not anaerobic capacity (AC, i.e., the metabolic energy demand). However, in sports that do not involve cycling movements (Karate), the continuous jump for 30 s (vertical jumps for 30 s) has been extensively used to measure anaerobic performance in all young athletes. Limited information’s are available concerning its validity and reliability especially in children. As such, the current study aimed to test validity and reliability of a continuous jumps test (the CJ30s), using WAnT as a reference. Thirteen female Karate kids (age: 11.07 ± 1.32 years; mass: 41.76 ± 15.32 kg; height: 152 ± 11.52 cm; training experience: 4.38 ± 2.14 years) were tested on three separate sessions. The first and second sessions were used to assess the reliability using Intra-class correlation coefficient (ICC) of CJ30s, whereas on the third session WAnT was administered. Following CJ30s and WAnT, we assessed AP (1/CJ30s, as jump height [JH], fatigue index [FI], and blood lactate [BL]; 2/WAnT, as mechanical power [P], FI, and BL) and AC as the excess post-exercise oxygen consumption (EPOC). Large/highly significant correlations were found between CJ30s and WAnT EPOCs (r = 0.730, P = 0.003), and BLs (r = 0.713, P = 0.009). Moderate/significant correlations were found between CJ30s and WAnT FIs (r = 0.640, P = 0.014), CJ30s first four jumps mean JH and WAnT peak P (r = 0.572, P = 0.032), and CJ30s mean JH and WAnT mean P (r = 0.589, P = 0.021). CJ30s showed excellent and moderate reliability (ICC) for AP (maximal JH 0.884, mean JH 0.742, FI 0.657, BL 0.653) and AC (EPOC 0.788), respectively. Correlations observed especially in terms of AC between CJ30s and WAnT provide evidence that former may adequately assess anaerobic performance for the young combat athlete. CJ30 is a reliable test and allow an easy assessment of AP and AC in karate children. PMID:29867580

  19. TECHNICAL ASSESSMENT OF FUEL CELL OPERATION ON ANAEROBIC DIGESTER GAS AT THE YONKERS, NY, WASTEWATER TREATMENT PLANT

    EPA Science Inventory

    The paper summarizes the results of a 2-year field test to assess the performance of a specially modified commercial phosphoric acid 200 kW fuel cell power plant to recover energy from anaerobic digester gas (ADG) which has been cleansed of contaminants (sulfur and halide compoun...

  20. Differential modeling of anaerobic and aerobic metabolism in the 800-m and 1,500-m run.

    PubMed

    Billat, Véronique; Hamard, Laurence; Koralsztein, Jean Pierre; Morton, R Hugh

    2009-08-01

    This study examined the hypothesis that running speed over 800- and 1,500-m races is regulated by the prevailing anaerobic (oxygen independent) store (ANS) at each instant of the race up until the all-out phase of the race over the last several meters. Therefore, we hypothesized that the anaerobic power that allows running above the speed at maximal oxygen uptake (VO2max) is regulated by ANS, and as a consequence the time limit at the anaerobic power (tlim PAN=ANS/PAN) is constant until the final sprint. Eight 800-m and seven 1,500-m male runners performed an incremental test to measure VO2max and the minimal velocity associated with the attainment of VO2max (vVO2max), referred to as maximal aerobic power, and ran the 800-m or 1,500-m race with the intent of achieving the lowest time possible. Anaerobic power (PAN) was measured as the difference between total power and aerobic power, and instantaneous ANS as the difference between end-race and instantaneous accumulated oxygen deficits. In 800 m and 1,500 m, tlim PAN was constant during the first 70% of race time in both races. Furthermore, the 1,500-m performance was significantly correlated with tlim PAN during this period (r=-0.92, P<0.01), but the 800-m performance was not (r=-0.05, P=0.89), although it was correlated with the end-race oxygen deficit (r=-0.70, P=0.05). In conclusion, this study shows that in middle-distance races over both 800 m and 1,500 m, the speed variations during the first 70% of the race time serve to maintain constant the time to exhaustion at the instantaneous anaerobic power. This observation is consistent with the hypothesis that at any instant running speed is controlled by the ANS remaining.

  1. Physiologic performance test differences in female volleyball athletes by competition level and player position.

    PubMed

    Schaal, Monique; Ransdell, Lynda B; Simonson, Shawn R; Gao, Yong

    2013-07-01

    The purpose of this study was to examine physiologic performance test differences by competition level (high school and Division-I collegiate athletes) and player position (hitter, setter, defensive specialist) in 4 volleyball-related tests. A secondary purpose was to establish whether a 150-yd shuttle could be used as a field test to assess anaerobic capacity. Female participants from 4 varsity high school volleyball teams (n = 27) and 2 Division-I collegiate volleyball teams (n = 26) were recruited for the study. Participants completed 4 performance-based field tests (vertical jump, agility T-test, and 150- and 300-yd shuttle runs) after completing a standardized dynamic warm-up. A 2-way multivariate analysis of variance with Bonferroni post hoc adjustments (when appropriate) and effect sizes were used for the analyses. The most important findings of this study were that (a) college volleyball athletes were older, heavier, and taller than high school athletes; (b) high school athletes had performance deficiencies in vertical jump/lower-body power, agility, and anaerobic fitness; (c) lower-body power was the only statistically significant difference in the performance test measures by player position; and (d) the correlation between the 150- and 300-yd shuttle was moderate (r = 0.488). Female high school volleyball players may enhance their ability to play collegiate volleyball by improving their vertical jump, lower-body power, agility, and anaerobic fitness. Furthermore, all player positions should emphasize lower-body power conditioning. These physical test scores provide baseline performance scores that should help strength and conditioning coaches create programs that will address deficits in female volleyball player performance, especially as they transition from high school to college.

  2. The 3-min all-out test is valid for determining critical power but not anaerobic work capacity in tethered running

    PubMed Central

    2018-01-01

    The purpose of the study was to investigate if the 3-min all-out test (3MT) is valid for obtaining critical power intensity (CP) and the amount of work that can be performed above CP (W’) on non-motorized treadmills in tethered running. Eight physically active individuals (24 ± 3 years; 78.3 ± 8.7 kg; 179 ± 5 cm; 9.0 ± 2.5% body fat) performed four different efforts at constant intensity to exhaustion in order to determine CP and W’. The mechanical power values obtained were subsequently plotted with their corresponding time to exhaustion (limit time) for application of three mathematical models: power hyperbolic versus time limit (Hyp), linear power versus 1/time (P vs 1/t) and linear work versus time limit (Ԏ vs t). The 3MT test was carried out on the last day to determine end power (EP) and anaerobic capacity (WEP) using this methodology. EP value of 181.7 ± 52 was similar (p = 0.486) to 178.2 ± 61 (CP Hyp), 191.4 ± 55 (Ԏ vs t) and 188.3 ± 55 (P vs 1/t). WEP value of 17.9 ± 4.8 was not similar (p = 0.000) to 50.2 ± 15.3 (CP Hyp), 44.8 ± 8.7 (Ԏ vs t) and 45.5 ± 8.4 (P vs 1/t). Positive results (r = 0.78–0.98 and ICC = 0.88–0.99) of Pearson correlation and intraclass correlation (ICC–absolute agreement) were found for aerobic applications of conventional CP and 3MT. For anaerobic data, only the three models of conventional CP were correlated (r = 0.76–0.93); however, W’ from the three models was not correlated with WEP (r = 0.37–0.52). The results of this study suggest that 3MT in tethered running on non-motorized treadmills is a valid test for estimating CP aerobic parameters in a single day of application but not anaerobic parameters of W’. PMID:29444141

  3. Effect of low-dose, short-duration creatine supplementation on anaerobic exercise performance.

    PubMed

    Hoffman, Jay R; Stout, Jeffrey R; Falvo, Michael J; Kang, Jie; Ratamess, Nicholas A

    2005-05-01

    To examine the efficacy of a low-dose, short-duration creatine monohydrate supplement, 40 physically active men were randomly assigned to either a placebo or creatine supplementation group (6 g of creatine monohydrate per day). Testing occurred before and at the end of 6 days of supplementation. During each testing session, subjects performed three 15-second Wingate anaerobic power tests. No significant (p > 0.05) group or time differences were observed in body mass, peak power, mean power, or total work. In addition, no significant (p > 0.05) differences were observed in peak power, mean power, or total work. However, the change in the rate of fatigue of total work was significantly (p < 0.05) lower in the creatine supplementation group than in the placebo group, indicating a reduced fatigue rate in subjects supplementing with creatine compared with the placebo. Although the results of this study demonstrated reduced fatigue rates in patients during high-intensity sprint intervals, further research is necessary in examining the efficacy of low-dose, short-term creatine supplementation.

  4. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    PubMed

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power ( r  = 0.446, p  < 0.0001) and SBJ (distance) in all sportsmen. Inter-sport correlation showed positive correlation between SBJ and peak power ( r  = 0.335, p  < 0.016) in Fencers and between SBJ, peak power ( r  = 0.686, p  < 0.002) in Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  5. Examination of a pre-exercise, high energy supplement on exercise performance

    PubMed Central

    Hoffman, Jay R; Kang, Jie; Ratamess, Nicholas A; Hoffman, Mattan W; Tranchina, Christopher P; Faigenbaum, Avery D

    2009-01-01

    Background The purpose of this study was to examine the effect of a pre-exercise high energy drink on reaction time and anaerobic power in competitive strength/power athletes. In addition, the effect of the pre-exercise drink on subjective feelings of energy, fatigue, alertness and focus was also explored. Methods Twelve male strength/power athletes (21.1 ± 1.3 y; 179.8 ± 7.1 cm; 88.6 ± 12.1 kg; 17.6 ± 3.3% body fat) underwent two testing sessions administered in a randomized and double-blind fashion. During each session, subjects reported to the Human Performance Laboratory and were provided with either 120 ml of a high energy drink (SUP), commercially marketed as Redline Extreme® or 120 ml of a placebo (PL) that was similar in taste and appearance but contained no active ingredients. Following consumption of the supplement or placebo subjects rested quietly for 10-minutes prior to completing a survey and commencing exercise. The survey consisted of 4 questions asking each subject to describe their feelings of energy, fatigue, alertness and focus for that moment. Following the completion of the questionnaire subjects performed a 2-minute quickness and reaction test on the Makoto testing device (Makoto USA, Centennial CO) and a 20-second Wingate Anaerobic Power test. Following a 10-minute rest subjects repeated the testing sequence and after a similar rest period a third and final testing sequence was performed. The Makoto testing device consisted of subjects reacting to both a visual and auditory stimulus and striking one out of 30 potential targets on three towers. Results Significant difference in reaction performance was seen between SUP and PL in both average number of targets struck (55.8 ± 7.4 versus 51.9 ± 7.4, respectively) and percent of targets struck (71.9 ± 10.5% versus 66.8 ± 10.9%, respectively). No significant differences between trials were seen in any anaerobic power measure. Subjective feelings of energy (3.5 ± 0.5 versus 3.1 ± 0.5) and focus (3.8 ± 0.5 versus 3.3 ± 0.7) were significantly higher during SUP compared to PL, respectively. In addition, a trend towards an increase in average alertness (p = 0.06) was seen in SUP compared to P. Conclusion Results indicate a significant increase in reaction performance, with no effect on anaerobic power performance. In addition, ingestion of this supplement significantly improves subjective feelings of focus and energy in male strength/power athletes. PMID:19126213

  6. The effect of caffeine as an ergogenic aid in anaerobic exercise.

    PubMed

    Woolf, Kathleen; Bidwell, Wendy K; Carlson, Amanda G

    2008-08-01

    The study examined caffeine (5 mg/kg body weight) vs. placebo during anaerobic exercise. Eighteen male athletes (24.1+/-5.8 yr; BMI 26.4+/-2.2 kg/m2) completed a leg press, chest press, and Wingate test. During the caffeine trial, more total weight was lifted with the chest press, and a greater peak power was obtained during the Wingate test. No differences were observed between treatments for the leg press and average power, minimum power, and power drop (Wingate test). There was a significant treatment main effect found for postexercise glucose and insulin concentrations; higher concentrations were found in the caffeine trial. A significant interaction effect (treatment and time) was found for cortisol and glucose concentrations; both increased with caffeine and decreased with placebo. Postexercise systolic blood pressure was significantly higher during the caffeine trial. No differences were found between treatments for serum free-fatty-acid concentrations, plasma lactate concentrations, serum cortisol concentrations, heart rate, and rating of perceived exertion. Thus, a moderate dose of caffeine resulted in more total weight lifted for the chest press and a greater peak power attained during the Wingate test in competitive athletes.

  7. Relationships between maximal anaerobic power of the arms and legs and javelin performance.

    PubMed

    Bouhlel, E; Chelly, M S; Tabka, Z; Shephard, R

    2007-06-01

    The aim of this study was to examine relationships between maximal anaerobic power, as measured by leg and arm force-velocity tests, estimates of local muscle volume and javelin performance. Ten trained national level male javelin throwers (mean age 19.6+/- 2 years) participated in this study. Maximal anaerobic power, maximal force and maximal velocity were measured during leg (Wmax-L) and arm (Wmax-A) force-velocity tests, performed on appropriately modified forms of Monark cycle ergometer. Estimates of leg and arm muscle volume were made using a standard anthropometric kit. Maximal force of the leg (Fmax-L) was significantly correlated with estimated leg muscle volume (r=0.71, P<0.05). Wmax-L and Wmax-A were both significantly correlated with javelin performance (r=0.76, P<0.01; r=0.71, P <0.05, respectively). Maximal velocity of the leg (Vmax-L) was also significantly correlated with throwing performance (r=0.83; P<0.001). Wmax of both legs and arms were significantly correlated with javelin performance, the closest correlation being for Wmax-L; this emphasizes the importance of the leg muscles in this sport. Fmax-L and Vmax-L were related to muscle volume and to javelin performance, respectively. Force-velocity testing may have value in regulating conditioning and rehabilitation in sports involving throwing.

  8. Short-term creatine supplementation has no impact on upper-body anaerobic power in trained wrestlers.

    PubMed

    Aedma, Martin; Timpmann, Saima; Lätt, Evelin; Ööpik, Vahur

    2015-01-01

    Creatine (CR) is considered an effective nutritional supplement having ergogenic effects, which appears more pronounced in upper-body compared to lower-body exercise. Nevertheless, results regarding the impact of CR loading on repeated high-intensity arm-cranking exercise are scarce and in some cases conflicting. Interestingly, few of the conducted studies have structured their research designs to mimic real world sporting events. Therefore, our purpose was to address the hypothesis that CR ingestion would increase anaerobic power output in consecutive upper-body intermittent sprint performance (UBISP) tests designed to simulate wrestling matches on a competition-day. In a double-blind, placebo-controlled, parallel-group study, 20 trained wrestlers were assigned to either placebo or CR supplemented group (0.3 g ∙ kg(-1) of body mass per day). Four 6-min UBISP tests interspersed with 30-min recovery periods were performed before (trial 1) and after 5 days (trial 2) of supplementation. Each test consisted of six 15-s periods of arm-cranking at maximal executable cadence against resistance of 0.04 kg ∙ kg(-1) body mass interspersed with 40-s unloaded easy cranking periods and 5-s acceleration intervals (T1-T4). Mean power (MP), peak power (PP), fatigue index and heart rate parameters were measured during UBISP tests. Also, body weight and hydration status were assessed. Principle measures were statistical analysed with mixed-model ANOVAs. Mean individual CR consumption in the CR group was 24.8 ± 2.5 g ∙ d(-1). No significant (P > 0.05) differences occurred in body mass or hydration status indices between the groups or across trials. MP, PP and fatigue index responses were unaffected by supplementation; although, a significant reduction in MP and PP did occurred from T1 to T4 in both trial 1 and 2 (P < 0.001). Overall heart rate responses in the tests tended to be higher in the CR than PLC group (P < 0.05); but, trends in responses in trials and tests were comparable (P > 0.05). These results suggest that 5-day CR supplementation has no impact on upper-body muscle anaerobic power output in consecutive UBISP anaerobic tests mimicking wrestling matches on a competition day.

  9. Maximal anaerobic power in Indian national hockey players.

    PubMed Central

    Bhanot, J. L.; Sidhu, L. S.

    1983-01-01

    Anaerobic power in relation to field position of 90 Indian hockey players has been studied. These players included 10 goalkeepers, 16 backs, 20 half-backs and 44 forwards. The goalkeepers possess maximum and forwards possess minimum anaerobic power while in vertical velocity, the former are the fastest and the latter are the slowest. In body weight the backs are heaviest followed by half-backs, goalkeepers and forwards. Among backs, the lefts are heavier, faster and have more anaerobic power than rights. In half-line players, the centre-half-backs are followed by left-half-backs and right-half-backs both in body weight and anaerobic power, while in vertical velocity, the left-half-backs are the fastest and centre-half-backs are the slowest. Among forwards, the centre-forwards are heaviest with maximum anaerobic power and are followed by inside-forwards and outside-forwards, whereas, in vertical velocity the inside-forwards are fastest followed by centre-forwards and outside-forwards. Images p34-a p34-b PMID:6850203

  10. Reference values for the muscle power sprint test in 6- to 12-year-old children.

    PubMed

    Douma-van Riet, Danielle; Verschuren, Olaf; Jelsma, Dorothee; Kruitwagen, Cas; Smits-Engelsman, Bouwien; Takken, Tim

    2012-01-01

    The aims of this study were (1) to develop centile reference values for anaerobic performance of Dutch children tested using the Muscle Power Sprint Test (MPST) and (2) to examine the test-retest reliability of the MPST. Children who were developing typically (178 boys and 201 girls) and aged 6 to 12 years (mean = 8.9 years) were recruited. The MPST was administered to 379 children, and test-retest reliability was examined in 47 children. MPST scores were transformed into centile curves, which were created using generalized additive models for location, scale, and shape. Height-related reference curves were created for both genders. Excellent (intraclass correlation coefficient = 0.98) test-retest reliability was demonstrated. The reference values for the MPST of children who are developing typically and aged 6 to 12 years can serve as a clinical standard in pediatric physical therapy practice. The MPST is a reliable and practical method for determining anaerobic performance in children.

  11. The Effect of a New Sodium Bicarbonate Loading Regimen on Anaerobic Capacity and Wrestling Performance.

    PubMed

    Durkalec-Michalski, Krzysztof; Zawieja, Emilia Ewa; Podgórski, Tomasz; Zawieja, Bogna Ewa; Michałowska, Patrycja; Łoniewski, Igor; Jeszka, Jan

    2018-05-30

    Gastrointestinal side effects are the main problem with sodium bicarbonate (SB) use in sports. Therefore, our study assessed the effect of a new SB loading regimen on anaerobic capacity and wrestling performance. Fifty-eight wrestlers were randomized to either a progressive-dose regimen of up to 100 mg∙kg -1 of SB or a placebo for 10 days. Before and after treatment, athletes completed an exercise protocol that comprised, in sequence, the first Wingate, dummy throw, and second Wingate tests. Blood samples were taken pre- and post-exercise. No gastrointestinal side effects were reported during the study. After SB treatment, there were no significant improvements in the outcomes of the Wingate and dummy throw tests. The only index that significantly improved with SB, compared to the placebo ( p = 0.0142), was the time-to-peak power in the second Wingate test, which decreased from 3.44 ± 1.98 to 2.35 ± 1.17 s. There were also no differences in blood lactate or glucose concentrations. In conclusion, although the new loading regimen eliminated gastrointestinal symptoms, the doses could have been too small to elicit additional improvements in anaerobic power and wrestling performance. However, shortening the time-to-peak power during fatigue may be particularly valuable and is one of the variables contributing to the final success of a combat sports athlete.

  12. Intermittent Theta Burst Over M1 May Increase Peak Power of a Wingate Anaerobic Test and Prevent the Reduction of Voluntary Activation Measured with Transcranial Magnetic Stimulation

    PubMed Central

    Giboin, Louis-Solal; Thumm, Patrick; Bertschinger, Raphael; Gruber, Markus

    2016-01-01

    Despite the potential of repetitive transcranial magnetic stimulation (rTMS) to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesized that after an intermittent theta burst (iTBS) treatment, performance during the Wingate Anaerobic Test (WAnT) will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment. Ten subjects participated in two randomized experiments consisting of a WAnT 5 min after either an iTBS or a control treatment. We determined voluntary activation (VA) of the right knee extensors with TMS (VATMS) and with peripheral nerve stimulation (VAPNS) of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a two way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioral changes related to fatigue (mean power and fatigue index) were observed. These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task. PMID:27486391

  13. Intermittent Theta Burst Over M1 May Increase Peak Power of a Wingate Anaerobic Test and Prevent the Reduction of Voluntary Activation Measured with Transcranial Magnetic Stimulation.

    PubMed

    Giboin, Louis-Solal; Thumm, Patrick; Bertschinger, Raphael; Gruber, Markus

    2016-01-01

    Despite the potential of repetitive transcranial magnetic stimulation (rTMS) to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesized that after an intermittent theta burst (iTBS) treatment, performance during the Wingate Anaerobic Test (WAnT) will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment. Ten subjects participated in two randomized experiments consisting of a WAnT 5 min after either an iTBS or a control treatment. We determined voluntary activation (VA) of the right knee extensors with TMS (VATMS) and with peripheral nerve stimulation (VAPNS) of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a two way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioral changes related to fatigue (mean power and fatigue index) were observed. These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task.

  14. Anaerobic upper and lower body power measurements and perception of fatigue during a kick boxing match.

    PubMed

    Ouergui, I; Hammouda, O; Chtourou, H; Zarrouk, N; Rebai, H; Chaouachi, A

    2013-10-01

    Objective of the study was to determine the effects of a kick-boxing match on muscle power of the upper and lower body as well as the associated perceived exertion in young men. Eighteen well trained kick-boxers volunteered to participate in a competitive sparring bout preceded and followed by three anaerobic tests as follow: squat jump (SJ) and counter movement jump (CMJ) for legs and 30-s Wingate test for arms. The sparring bout consisted of three 2 min rounds with 1 min recovery period in-between. Blood lactate (BL), heart rate (HR) and rating of perceived exertion (RPE) were analyzed before and after each round. The results showed that vertical jump distance in SJ and CMJ were significantly lower after the kick-boxing match (27.92±3.84 vs. 25.28±4.39 cm; 29.8±5.33 vs 28.48±4.64 cm, for SJ and CMJ respectively). Likewise, peak and mean power in the Wingate test decreased significantly after the sparring bout (5.89±0. 69 vs. 5.26±0.66 W•kg-1 and 4.51±0.53 vs. 4.12±0.51 W•kg-1 for PP and MP respectively; P<0.001). Moreover, we found a significant increase in BL, HR, and RPE after the kick-boxing match (P<0.001). BL increased significantly after the second and third round from the post round one values' (P<0.001). These findings showed that a single kick-boxing match is of sufficient intensity to stress the anaerobic metabolism. Thus, training protocols should include exercises that train the anaerobic energetic pathways for upper and lower body.

  15. The Measurement of Maximal (Anaerobic) Power Output on a Cycle Ergometer: A Critical Review

    PubMed Central

    Driss, Tarak; Vandewalle, Henry

    2013-01-01

    The interests and limits of the different methods and protocols of maximal (anaerobic) power (P max) assessment are reviewed: single all-out tests versus force-velocity tests, isokinetic ergometers versus friction-loaded ergometers, measure of P max during the acceleration phase or at peak velocity. The effects of training, athletic practice, diet and pharmacological substances upon the production of maximal mechanical power are not discussed in this review mainly focused on the technical (ergometer, crank length, toe clips), methodological (protocols) and biological factors (muscle volume, muscle fiber type, age, gender, growth, temperature, chronobiology and fatigue) limiting P max in cycling. Although the validity of the Wingate test is questionable, a large part of the review is dedicated to this test which is currently the all-out cycling test the most often used. The biomechanical characteristics specific of maximal and high speed cycling, the bioenergetics of the all-out cycling exercises and the influence of biochemical factors (acidosis and alkalosis, phosphate ions…) are recalled at the beginning of the paper. The basic knowledge concerning the consequences of the force-velocity relationship upon power output, the biomechanics of sub-maximal cycling exercises and the study on the force-velocity relationship in cycling by Dickinson in 1928 are presented in Appendices. PMID:24073413

  16. Electricity Production and Characterization of High-Strength Industrial Wastewaters in Microbial Fuel Cell.

    PubMed

    Cetinkaya, Afsin Y; Ozdemir, Oguz Kaan; Demir, Ahmet; Ozkaya, Bestami

    2017-06-01

    Microbial fuel cells (MFCs) convert electrochemical energy into electrical energy immediately and have a big potential usage for the same time wastewater treatment and energy recovery via electro-active microorganisms. However, MFCs must be efficiently optimized due to its limitations such as high cost and low power production. Finding new materials to increase the cell performance and reduce cost for MFC anodes is mandatory. In the first step of this study, different inoculation sludges such as anaerobic gum industry wastewater, anaerobic brewery wastewater and anaerobic phosphate were tested, and MFC that was set up with anaerobic gum industry wastewater inoculation sludge exhibited the highest performance. In the second step of this study, various wastewaters such as chocolate industry, gum industry and slaughterhouse industry were investigated for anode bacteria sources. Several electrochemical techniques have been employed to elucidate how wastewaters affect the MFCs' performance. Among all the mentioned wastewaters, the best performance was achieved by the MFCs fed with slaughterhouse wastewater; this device produced a maximum power density of 267 mW·m -2 .

  17. Supplementation with a Polyphenol-Rich Extract, PerfLoad®, Improves Physical Performance during High-Intensity Exercise: A Randomized, Double Blind, Crossover Trial

    PubMed Central

    Cases, Julien; Romain, Cindy; Marín-Pagán, Cristian; Chung, Linda H.; Rubio-Pérez, José Miguel; Laurent, Caroline; Gaillet, Sylvie; Prost-Camus, Emmanuelle; Prost, Michel; Alcaraz, Pedro E.

    2017-01-01

    Workout capacity is energy-production driven. To produce peak metabolic power outputs, the organism predominantly relies more on anaerobic metabolism, but this undoubtedly has a negative and limiting impact on muscle function and performance. The aim of the study was to evaluate if an innovative polyphenol-based food supplement, PerfLoad®, was able to improve metabolic homeostasis and physical performance during high-intensity exercises under anaerobic conditions. The effect of a supplementation has been investigated on fifteen recreationally-active male athletes during a randomized, double-blind and crossover clinical investigation. The Wingate test, an inducer of an unbalanced metabolism associated to oxidative stress, was used to assess maximum anaerobic power during a high-intensity exercise on a cycle ergometer. Supplementation with PerfLoad® correlated with a significant increase in total power output (5%), maximal peak power output (3.7%), and average power developed (5%), without inducing more fatigue or greater heart rate. Instead, oxidative homeostasis was stabilized in supplemented subjects. Such results demonstrated that PerfLoad® is a natural and efficient solution capable of, similarly to training benefits, helping athletes to improve their physical performance, while balancing their metabolism and reducing exercise-induced oxidative stress. PMID:28441760

  18. Caffeine ingestion enhances Wingate performance: a meta-analysis.

    PubMed

    Grgic, Jozo

    2018-03-01

    The positive effects of caffeine ingestion on aerobic performance are well-established; however, recent findings are suggesting that caffeine ingestion might also enhance components of anaerobic performance. A commonly used test of anaerobic performance and power output is the 30-second Wingate test. Several studies explored the effects of caffeine ingestion on Wingate performance, with equivocal findings. To elucidate this topic, this paper aims to determine the effects of caffeine ingestion on Wingate performance using meta-analytic statistical techniques. Following a search through PubMed/MEDLINE, Scopus, and SportDiscus ® , 16 studies were found meeting the inclusion criteria (pooled number of participants = 246). Random-effects meta-analysis of standardized mean differences (SMD) for peak power output and mean power output was performed. Study quality was assessed using the modified version of the PEDro checklist. Results of the meta-analysis indicated a significant difference (p = .005) between the placebo and caffeine trials on mean power output with SMD values of small magnitude (0.18; 95% confidence interval: 0.05, 0.31; +3%). The meta-analysis performed for peak power output indicated a significant difference (p = .006) between the placebo and caffeine trials (SMD = 0.27; 95% confidence interval: 0.08, 0.47 [moderate magnitude]; +4%). The results from the PEDro checklist indicated that, in general, studies are of good and excellent methodological quality. This meta-analysis adds on to the current body of evidence showing that caffeine ingestion can also enhance components of anaerobic performance. The results presented herein may be helpful for developing more efficient evidence-based recommendations regarding caffeine supplementation.

  19. The relationship between the yo-yo tests, anaerobic performance and aerobic performance in young soccer players.

    PubMed

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-12-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1-2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = -0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = -0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players.

  20. The Relationship Between the Yo-Yo Tests, Anaerobic Performance and Aerobic Performance in Young Soccer Players

    PubMed Central

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-01-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1–2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = −0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = −0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players. PMID:23486008

  1. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance

    PubMed Central

    KENDALL, BRADLEY J.

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F(4,36) = 3.90, p = .01, partial η2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies. PMID:28479947

  2. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance.

    PubMed

    Kendall, Bradley J

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F (4,36) = 3.90, p = .01, partial η 2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies.

  3. Pacing Strategy in Short Cycling Time Trials.

    PubMed

    de Jong, Jelle; van der Meijden, Linda; Hamby, Simone; Suckow, Samantha; Dodge, Christopher; de Koning, Jos J; Foster, Carl

    2015-11-01

    To reach top performance in cycling, optimizing distribution of energy resources is crucial. The purpose of this study was to investigate power output during 250-m, 500-m, and 1000-m cycling time trials and the characteristics of the adopted pacing strategy. Nine trained cyclists completed an incremental test and 3 time trials that they were instructed to finish as quickly as possible. Preceding the trials, peak power during short sprints (PP sprint) and gross efficiency (GE) were measured. During the trials, power output and oxygen consumption were measured to calculate the contribution of the aerobic and anaerobic energy sources. After the trial GE was measured again. Peak power during all trials (PPTT) was lower than PP sprint. In the 250-m trial the PPTT was higher in the 1000-m trial (P = .008). The subjects performed a significantly longer time at high intensity in the 250-m than in the 1000-m (P = .029). GE declined significantly during all trials (P < .01). Total anaerobically attributable work was less in the 250-m than in the 500-m (P = .015) and 1000-m (P < .01) trials. The overall pacing pattern in the 250-m trial appears to follow an all-out strategy, although peak power is still lower than the potential maximal power output. This suggests that a true all-out pattern of power output may not be used in fixed-distance events. The 500-m and 1000-m had a more conservative pacing pattern and anaerobic power output reached a constant magnitude.

  4. Contributions of Body-Composition Characteristics to Critical Power and Anaerobic Work Capacity.

    PubMed

    Byrd, M Travis; Switalla, Jonathan Robert; Eastman, Joel E; Wallace, Brian J; Clasey, Jody L; Bergstrom, Haley C

    2018-02-01

    Critical power (CP) and anaerobic work capacity (AWC) from the CP test represent distinct parameters related to metabolic characteristics of the whole body and active muscle tissue, respectively. To examine the contribution of whole-body composition characteristics and local lean mass to further elucidate the differences in metabolic characteristics between CP and AWC as they relate to whole body and local factors. Fifteen anaerobically trained men were assessed for whole-body (% body fat and mineral-free lean mass [LBM]) and local mineral-free thigh lean mass (TLM) composition characteristics. CP and AWC were determined from the 3-min all-out CP test. Statistical analyses included Pearson product-moment correlations and stepwise multiple-regression analyses (P ≤ .05). Only LBM contributed significantly to the prediction of CP (CP = 2.3 [LBM] + 56.7 [r 2  = .346, standard error of the estimate (SEE) = 31.4 W, P = .021]), and only TLM to AWC (AWC = 0.8 [TLM] + 3.7 [r 2  = .479, SEE = 2.2 kJ, P = .004]). The aerobic component (CP) of the CP test was most closely related to LBM, and the anaerobic component (AWC) was more closely related to the TLM. These findings support the theory that CP and AWC are separate measures of whole-body metabolic capabilities and the energy stores in the activated local muscle groups, respectively. Thus, training programs to improve CP and AWC should be designed to include resistance-training exercises to increase whole-body LBM and local TLM.

  5. n-3 Fatty Acid Supplementation During 4 Weeks of Training Leads to Improved Anaerobic Endurance Capacity, but not Maximal Strength, Speed, or Power in Soccer Players.

    PubMed

    Gravina, Leyre; Brown, Frankie F; Alexander, Lee; Dick, James; Bell, Gordon; Witard, Oliver C; Galloway, Stuart D R

    2017-08-01

    Omega-3 fatty acid (n-3 FA) supplementation could promote adaptation to soccer-specific training. We examined the impact of a 4-week period of n-3 FA supplementation during training on adaptations in 1RM knee extensor strength, 20-m sprint speed, vertical jump power, and anaerobic endurance capacity (Yo-Yo test) in competitive soccer players. Twenty six soccer players were randomly assigned to one of two groups: n-3 FA supplementation (n-3 FA; n = 13) or placebo (n = 13). Both groups performed two experimental trial days. Assessments of physical function and respiratory function were conducted pre (PRE) and post (POST) supplementation. Training session intensity, competitive games and nutritional intake were monitored during the 4-week period. No differences were observed in respiratory measurements (FEV1, FVC) between groups. No main effect of treatment was observed for 1RM knee extensor strength, explosive leg power, or 20 m sprint performance, but strength improved as a result of the training period in both groups (p < .05). Yo-Yo test distance improved with training in the n-3 FA group only (p < .01). The mean difference (95% CI) in Yo-Yo test distance completed from PRE to POST was 203 (66-340) m for n-3 FA, and 62 (-94-217) m for placebo, with a moderate effect size (Cohen's d of 0.52). We conclude that 4 weeks of n-3 FA supplementation does not improve strength, power or speed assessments in competitive soccer players. However, the increase in anaerobic endurance capacity evident only in the n-3 FA treatment group suggests an interaction that requires further study.

  6. The acute effects of multi-ingredient pre-workout ingestion on strength performance, lower body power, and anaerobic capacity.

    PubMed

    Jagim, Andrew R; Jones, Margaret T; Wright, Glenn A; St Antoine, Carly; Kovacs, Attila; Oliver, Jonathan M

    2016-01-01

    Multi-ingredient pre-workout supplements (MIPS) are popular among resistance trained individuals. Previous research has indicated that acute MIPS ingestion may increase muscular endurance when using a hypertrophy-based protocol but less is known in regard to their effects on strength performance and high intensity running capacity. Therefore, the purpose was to determine if short-term, MIPS ingestion influences strength performance and anaerobic running capacity. In a double-blind, randomized, placebo controlled, crossover design; 12 males (19 ± 1 yrs.; 180 ± 12 cm; 89.3 ± 11 kg; 13.6 ± 4.9 %BF) had their body composition assessed followed by 5-repetition maximum (5RM) determination of back squat (BS; 119.3 ± 17.7 kg) and bench press (BP; 92.1 ± 17.8 kg) exercises. On two separate occasions subjects ingested a MIPS or a placebo (P) 30-minutes prior to performing a counter movement vertical jump test, 5 sets of 5 repetitions at 85 % of 5RM of BS and BP, followed by a single set to failure, and an anaerobic capacity sprint test to assess peak and mean power. Subjective markers of energy levels and fatigue were also assessed. Subjects returned one week later for a second testing session using counter treatment. MIPS resulted in a greater number of repetitions performed in the final set to failure in the BP (MIPS, 9.8 ± 1.7 repetitions; P, 9.1 ± 2; p = 0.03, d = 0.38), which led to a greater total volume load (set x repetitions x load) in the MIPS (753 ± 211 kg) compared to P (710 ± 226 kg; p =0.03, d = .20). MIPS ingestion improved subjective markers of fatigue (p = 0.01, d = 3.78) and alertness (p = 0.048, d = 2.72) following a bout of resistance training. An increase in mean power was observed in the MIPS condition (p = 0.03, d = 0.25) during the anaerobic sprint test. Results suggest that acute ingestion of a MIPS study may increase upper body muscular endurance. In addition, acute MIPS ingestion improved mean power output during an anaerobic capacity sprint test. However, the practical significance of these performance related outcomes may be minimal due to the small effect sizes observed. MIPS ingestion does appear to positively influence subjective markers of fatigue and alertness during high-intensity exercise.

  7. The effects of whole-body vibration on the Wingate test for anaerobic power when applying individualized frequencies.

    PubMed

    Surowiec, Rachel K; Wang, Henry; Nagelkirk, Paul R; Frame, Jeffrey W; Dickin, D Clark

    2014-07-01

    Recently, individualized frequency (I-Freq) has been introduced with the notion that athletes may elicit a greater reflex response at differing levels (Hz) of vibration. The aim of the study was to evaluate acute whole-body vibration as a feasible intervention to increase power in trained cyclists and evaluate the efficacy of using I-Freq as an alternative to 30Hz, a common frequency seen in the literature. Twelve highly trained, competitive male cyclists (age, 29.9 ± 10.0 years; body height, 175.4 ± 7.8 cm; body mass, 77.3 ± 13.9 kg) participated in the study. A Wingate test for anaerobic power was administered on 3 occasions: following a control of no vibration, 30 Hz, or I-freq. Measures of peak power, average power (AP), and the rate of fatigue were recorded and compared with the vibration conditions using separate repeated measures analysis of variance. Peak power, AP, and the rate of fatigue were not significantly impacted by either the 30 Hz or I-Freq vibration interventions (p > 0.05). Given the trained status of the individuals in this study, the ability to elicit an acute response may have been muted. Future studies should further refine the vibration parameters used and assess changes in untrained or recreationally trained populations.

  8. Combined Effects of Lignosus rhinocerotis Supplementation and Resistance Training on Isokinetic Muscular Strength and Power, Anaerobic and Aerobic Fitness Level, and Immune Parameters in Young Males.

    PubMed

    Chen, Chee Keong; Hamdan, Nor Faeiza; Ooi, Foong Kiew; Wan Abd Hamid, Wan Zuraida

    2016-01-01

    This study investigated the effects of Lignosus rhinocerotis (LRS) supplementation and resistance training (RT) on isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters in young males. Participants were randomly assigned to four groups: Control (C), LRS, RT, and combined RT-LRS (RT-LRS). Participants in the LRS and RT-LRS groups consumed 500 mg of LRS daily for 8 weeks. RT was conducted 3 times/week for 8 weeks for participants in the RT and RT-LRS groups. The following parameters were measured before and after the intervention period: Anthropometric data, isokinetic muscular strength and power, and anaerobic and aerobic fitness. Blood samples were also collected to determine immune parameters. Isokinetic muscular strength and power were increased ( P < 0.05) in participants of both RT and RT-LRS groups. RT-LRS group had shown increases ( P < 0.05) in shoulder extension peak torque, shoulder flexion and extension average power, knee flexion peak torque, and knee flexion and extension average power. There were also increases ( P < 0.05) in anaerobic power and capacity and aerobic fitness in this group. Similarly, RT group had increases ( P < 0.05) in shoulder flexion average power, knee flexion and extension peak torque, and knee flexion and extension average power. In addition, increases ( P < 0.05) in anaerobic power and capacity, aerobic fitness, T lymphocytes (CD3 and CD4), and B lymphocytes (CD19) counts were observed in the RT group. RT elicited increased isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters among young males. However, supplementation with LRS during RT did not provide additive benefits.

  9. Combined Effects of Lignosus rhinocerotis Supplementation and Resistance Training on Isokinetic Muscular Strength and Power, Anaerobic and Aerobic Fitness Level, and Immune Parameters in Young Males

    PubMed Central

    Chen, Chee Keong; Hamdan, Nor Faeiza; Ooi, Foong Kiew; Wan Abd Hamid, Wan Zuraida

    2016-01-01

    Background: This study investigated the effects of Lignosus rhinocerotis (LRS) supplementation and resistance training (RT) on isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters in young males. Methods: Participants were randomly assigned to four groups: Control (C), LRS, RT, and combined RT-LRS (RT-LRS). Participants in the LRS and RT-LRS groups consumed 500 mg of LRS daily for 8 weeks. RT was conducted 3 times/week for 8 weeks for participants in the RT and RT-LRS groups. The following parameters were measured before and after the intervention period: Anthropometric data, isokinetic muscular strength and power, and anaerobic and aerobic fitness. Blood samples were also collected to determine immune parameters. Results: Isokinetic muscular strength and power were increased (P < 0.05) in participants of both RT and RT-LRS groups. RT-LRS group had shown increases (P < 0.05) in shoulder extension peak torque, shoulder flexion and extension average power, knee flexion peak torque, and knee flexion and extension average power. There were also increases (P < 0.05) in anaerobic power and capacity and aerobic fitness in this group. Similarly, RT group had increases (P < 0.05) in shoulder flexion average power, knee flexion and extension peak torque, and knee flexion and extension average power. In addition, increases (P < 0.05) in anaerobic power and capacity, aerobic fitness, T lymphocytes (CD3 and CD4), and B lymphocytes (CD19) counts were observed in the RT group. Conclusions: RT elicited increased isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters among young males. However, supplementation with LRS during RT did not provide additive benefits. PMID:27833721

  10. Acute Effects of a Caffeine-Containing Supplement on Anaerobic Power and Subjective Measurements of Fatigue in Recreationally Active Men.

    PubMed

    Hahn, Chelsea J; Jagim, Andrew R; Camic, Clayton L; Andre, Matthew J

    2018-04-01

    Hahn, CJ, Jagim, AR, Camic, CL, and Andre, MJ. Acute effects of a caffeine-containing supplement on anaerobic power and subjective measurements of fatigue in recreationally active men. J Strength Cond Res 32(4): 1029-1035, 2018-Studies show mixed results for the effects of caffeine on performance, warranting further investigation. The purpose of this study was to examine the acute effects of a caffeine-containing supplement on anaerobic power and subjective measurements of fatigue during resisted sprinting on men. Fourteen recreationally active men (N = 14; [mean ± SD], age: 21.0 ± 0.7 years, height: 178.5 ± 5.1 cm, body mass: 77.3 ± 9.6 kg, and percent body fat: 12.6 ± 4.8%) participated in a double-blind, placebo-controlled, within-subject crossover design study. The first visit required each participant to complete 3 sets of practice sprints on a nonmotorized treadmill ranging from 10 to 20 seconds. During the second visit, participants completed 5 more practice sprints ranging from 15 to 25 seconds. During the third and fourth visits, participants ingested one serving of a caffeine-containing or placebo beverage (the opposite beverage was consumed during the fourth visit), rested for 20 minutes, and completed a dynamic warm-up before sprinting. Anaerobic power was assessed using a countermovement vertical jump and nonmotorized treadmill sprint test. Psychological variables were scored using a 5-point Likert scale. No significant (p ≤ 0.05) differences were observed between conditions for average (p = 0.22) or peak power (p = 0.43). Both conditions resulted in a significant increase in fatigue, although the increase was less for the caffeine condition (caffeine [INCREMENT] = 0.93 and placebo [INCREMENT] = 1.71). These findings indicated that the caffeine-containing supplement improved perceived measures of fatigue but not power indices assessed through vertical jump or nonmotorized treadmill sprinting. The consumption of a caffeine beverage may be beneficial for reducing perceived fatigue during acute anaerobic exercise, particularly when repeated sprints are used.

  11. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training.

    PubMed

    Stöggl, Thomas L; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male ( n = 33) and female ( n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO 2peak ): 61.9 ± 8.0 mL·kg -1 ·min -1 ] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001) and peak lactate ( P = 0.001) during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L -1 ) was changed ( P > 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes.

  12. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    PubMed Central

    Stöggl, Thomas L.; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001) and peak lactate (P = 0.001) during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1) was changed (P > 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes. PMID:28824457

  13. Influence of warm-up duration and recovery interval prior to exercise on anaerobic performance.

    PubMed

    Frikha, M; Chaâri, N; Mezghanni, N; Souissi, N

    2016-12-01

    The purpose of the study was to determine the impact of different active warm-up (AWU) durations and the rest interval separating it from exercise on anaerobic performance. Eleven male physical education students (22.6 ± 2.52 years; 179.2 ± 4.3 cm; 82.5 ± 9.7 kg; mean ± SD) participated in a cross-over randomized study, and they all underwent the Wingate test after three AWU durations: 5 min (AWU5), 15 min (AWU15) and 20 min (AWU20), with recovery (WREC) or without a recovery interval (NREC) separating the AWU and anaerobic exercise performance. All the AWUs consisted of pedalling at a constant pace of 60 rpm at 50% of the maximal aerobic power. The rest interval between the end of warm-up and the beginning of exercise was set at 5 min. During the Wingate test, peak power (PP), mean power (MP) and the fatigue index (FI) were recorded and analysed. Oral temperature was recorded at rest and at the end of the warm-up. Likewise, rest, post-warm-up and post-Wingate heart rate (HR) and rating of perceived exertion (RPE) were recorded during each session. The ANOVA showed a significant effect of recovery interval, warm-up duration and measurement point on RPE scores (P<0.001). Although the effect of AWU duration on MP and PP was significant (P<0.05), the effect of the recovery interval on both parameters was not significant (P>0.05). Moreover, the analyses showed a significant interaction between recovery interval and AWU duration (P<0.001 and P<0.05 for MP and PP respectively). The AWU15 duration improves the MP and PP when associated with a recovery interval prior to exercise of 5 min. However, the AWU5 duration allows better improvement of power output when the exercise is applied immediately after the warm-up. Consequently, physically active males, as well as educators and researchers interested in anaerobic exercise, must take into account the duration of warm-up and the following recovery interval when practising or assessing activities requiring powerful lower limb muscle contractions.

  14. [Determination of the anaerobic threshold by the rate of ventilation and cardio interval variability].

    PubMed

    Seluianov, V N; Kalinin, E M; Pak, G D; Maevskaia, V I; Konrad, A H

    2011-01-01

    The aim of this work is to develop methods for determining the anaerobic threshold according to the rate of ventilation and cardio interval variability during the test with stepwise increases load on the cycle ergometer and treadmill. In the first phase developed the method for determining the anaerobic threshold for lung ventilation. 49 highly skilled skiers took part in the experiment. They performed a treadmill ski-walking test with sticks with gradually increasing slope from 0 to 25 degrees, the slope increased by one degree every minute. In the second phase we developed a method for determining the anaerobic threshold according dynamics ofcardio interval variability during the test. The study included 86 athletes of different sports specialties who performed pedaling on the cycle ergometer "Monarch" in advance. Initial output was 25 W, power increased by 25 W every 2 min. The pace was steady--75 rev/min. Measurement of pulmonary ventilation and oxygen and carbon dioxide content was performed using gas analyzer COSMED K4. Sampling of arterial blood was carried from the ear lobe or finger, blood lactate concentration was determined using an "Akusport" instrument. RR-intervals registration was performed using heart rate monitor Polar s810i. As a result, it was shown that the graphical method for determining the onset of anaerobic threshold ventilation (VAnP) coincides with the accumulation of blood lactate 3.8 +/- 0.1 mmol/l when testing on a treadmill and 4.1 +/- 0.6 mmol/1 on the cycle ergometer. The connection between the measure of oxygen consumption at VAnP and the dispersion of cardio intervals (SD1), derived regression equation: VO2AnT = 0.35 + 0.01SD1W + 0.0016SD1HR + + 0.106SD1(ms), l/min; (R = 0.98, error evaluation function 0.26 L/min, p < 0.001), where W (W)--Power, HR--heart rate (beats/min), SD1--cardio intervals dispersion (ms) at the moment of registration of cardio interval threshold.

  15. Vertical Jumping Tests versus Wingate Anaerobic Test in Female Volleyball Players: The Role of Age

    PubMed Central

    Nikolaidis, Pantelis Theodoros; Afonso, Jose; Clemente-Suarez, Vicente Javier; Alvarado, Jose Rafael Padilla; Driss, Tarak; Knechtle, Beat; Torres-Luque, Gema

    2016-01-01

    Single and continuous vertical jumping tests, as well as the Wingate anaerobic test (WAnT), are commonly used to assess the short-term muscle power of female volleyball players; however, the relationship among these tests has not been studied adequately. Thus, the aim of the present study was to examine the relationship of single and continuous vertical jumps with the WAnT in female volleyball players. Seventy adolescent (age 16.0 ± 1.0 years, body mass 62.5 ± 7.1 kg, height 170.4 ± 6.1 cm, body fat 24.2% ± 4.3%) and 108 adult female volleyball players (age 24.8 ± 5.2 years, body mass 66.5 ± 8.7 kg, height 173.2 ± 7.4 cm, body fat 22.0% ± 5.1%) performed the squat jump (SJ), countermovement jump (CMJ), Abalakov jump (AJ), 30 s Bosco test and WAnT (peak power, Ppeak; mean power, Pmean). Mean power in the Bosco test was correlated (low to large magnitude) with Pmean of the WAnT (r = 0.27, p = 0.030 in adolescents versus r = 0.56, p < 0.001 in adults). SJ, CMJ and AJ also correlated with Ppeak (0.28 ≤ r ≤ 0.46 in adolescents versus 0.58 ≤ r ≤ 0.61 in adults) and with Pmean (0.43 ≤ r ≤ 0.51 versus 0.67 ≤ r ≤ 0.71, respectively) of the WAnT (p < 0.05). In summary, the impact of the Bosco test and WAnT on muscle power varied, especially in the younger age group. Single jumping tests had larger correlations with WAnT in adults than in adolescent volleyball players. These findings should be taken into account by volleyball coaches and fitness trainers during the assessment of short-term muscle power of their athletes.

  16. Multimodal high-intensity interval training increases muscle function and metabolic performance in females.

    PubMed

    Buckley, Stephanie; Knapp, Kelly; Lackie, Amy; Lewry, Colin; Horvey, Karla; Benko, Chad; Trinh, Jason; Butcher, Scotty

    2015-11-01

    High-intensity interval training (HIIT) is a time-efficient method of improving aerobic and anaerobic power and capacity. In most individuals, however, HIIT using modalities such as cycling, running, and rowing does not typically result in increased muscle strength, power, or endurance. The purpose of this study is to compare the physiological outcomes of traditional HIIT using rowing (Row-HIIT) with a novel multimodal HIIT (MM-HIIT) circuit incorporating multiple modalities, including strength exercises, within an interval. Twenty-eight recreationally active women (age 24.7 ± 5.4 years) completed 6 weeks of either Row-HIIT or MM-HIIT and were tested on multiple fitness parameters. MM-HIIT and Row-HIIT resulted in similar improvements (p < 0.05 for post hoc pre- vs. post-training increases for each group) in maximal aerobic power (7% vs. 5%), anaerobic threshold (13% vs. 12%), respiratory compensation threshold (7% vs. 5%), anaerobic power (15% vs. 12%), and anaerobic capacity (18% vs. 14%). The MM-HIIT group had significant (p < 0.01 for all) increases in squat (39%), press (27%), and deadlift (18%) strength, broad jump distance (6%), and squat endurance (280%), whereas the Row-HIIT group had no increase in any muscle performance variable (p values 0.33-0.90). Post-training, 1-repetition maximum (1RM) squat (64.2 ± 13.6 vs. 45.8 ± 16.2 kg, p = 0.02), 1RM press (33.2 ± 3.8 vs. 26.0 ± 9.6 kg, p = 0.01), and squat endurance (23.9 ± 12.3 vs. 10.2 ± 5.6 reps, p < 0.01) were greater in the MM-HIIT group than in the Row-HIIT group. MM-HIIT resulted in similar aerobic and anaerobic adaptations but greater muscle performance increases than Row-HIIT in recreationally active women.

  17. Effects of protein supplementation on muscular performance and resting hormonal changes in college football players.

    PubMed

    Hoffman, Jay R; Ratamess, Nicholas A; Kang, Jie; Falvo, Michael J; Faigenbaum, Avery D

    2007-01-01

    The effect of protein supplementation on athletic performance and hormonal changes was examined in 21 experienced collegiate strength/power athletes participating in a 12-week resistance training program. Subjects were randomly assigned to either a protein supplement (PR; n = 11) or a placebo (PL; n = 10) group. During each testing session subjects were assessed for strength (one repetition maximum [1-RM] bench press and squat), power (Wingate anaerobic power test) and body composition. Resting blood samples were analyzed at weeks 0 (PRE), 6 (MID) and 12 (POST) for total testosterone, cortisol, growth hormone, and IGF-1. No difference was seen in energy intake between PR and PL (3034 ± 209 kcal and 3130 ± 266 kcal, respectively), but a significant difference in daily protein intake was seen between PR (2.00 g·kg body mass[BM](-1)·d(-1)) and PL (1.24 g·kgBM(-1)·d(-1)). A greater change (p < 0.05) in the ∆ 1-RM squat was seen in PR (23.5 ± 13.6 kg) compared to PL (9.1 ± 11.9 kg). No other significant strength or power differences were seen between the groups. Cortisol concentrations were significantly lower at MID for PL and this difference was significantly different than PR. No significant changes were noted in resting growth hormone or IGF-1 concentrations in either group. Although protein supplementation appeared to augment lower body strength development, similar upper body strength, anaerobic power and lean tissue changes do not provide clear evidence supporting the efficacy of a 12-week protein supplementation period in experienced resistance trained athletes. Key pointsCollegiate strength/power athletes may not meet daily recommended energy or protein needs.When athletes are provided a protein supplement they appear to meet the recommended daily protein intake for strength/power athletes.Protein supplementation did augment lower body strength development in experienced strength/power athletes.Results of upper body strength, anaerobic power and lean tissue changes did not support the efficacy of a 12-week protein supplementation period in experienced resistance trained athletes.

  18. PPARA intron polymorphism associated with power performance in 30-s anaerobic Wingate Test.

    PubMed

    Petr, Miroslav; Stastny, Petr; Št'astný, Petr; Pecha, Ondřej; Šteffl, Michal; Šeda, Ondřej; Kohlíková, Eva

    2014-01-01

    To date, polymorphisms in several genes have been associated with a strength/power performance including alpha 3 actinin, ciliary neurotrophic factor, vitamin D receptor, or angiotensin I converting enzyme, underlining the importance of genetic component of the multifactorial strength/power-related phenotypes. The single nucleotide variation in peroxisome proliferator-activated receptor alpha gene (PPARA) intron 7 G/C (rs4253778; g.46630634G>C) has been repeatedly found to play a significant role in response to different types of physical activity. We investigated the effect of PPARA intron 7 G/C polymorphism specifically on anaerobic power output in a group of 77 elite male Czech ice hockey players (18-36 y). We determined the relative peak power per body weight (Pmax.kg(-1)) and relative peak power per fat free mass (W.kg(-1)FFM) during the 30-second Wingate Test (WT30) on bicycle ergometer (Monark 894E Peak bike, MONARK, Sweden). All WT30s were performed during the hockey season. Overall genotype frequencies were 50.6% GG homozygotes, 40.3% CG heterozygotes, and 9.1% CC homozygotes. We found statistically significant differences in Pmax.kg(-1) and marginally significant differences in Pmax.kg(-1)FFM values in WT30 between carriers and non-carriers for C allele (14.6 ± 0.2 vs. 13.9 ± 0.3 W.kg(-1) and 15.8 ± 0.2 vs. 15.2 ± 0.3 W.kg(-1)FFM, P = 0.036 and 0.12, respectively). Furthermore, Pmax.kg(-1)FFM strongly positively correlated with the body weight only in individuals with GG genotypes (R = 0.55; p<0.001). Our results indicate that PPARA 7C carriers exhibited higher speed strength measures in WT30. We hypothesize that C allele carriers within the cohort of trained individuals may possess a metabolic advantage towards anaerobic metabolism.

  19. Incorporating sprint training with endurance training improves anaerobic capacity and 2,000-m Erg performance in trained oarsmen.

    PubMed

    Stevens, Alexander W J; Olver, Terry T; Lemon, Peter W R

    2015-01-01

    A 2,000-m time-trial performance, aerobic capacity, and anaerobic capacity were assessed in 16 trained oarsmen after sprint interval training (SIT) replaced a portion of an endurance-based training program (EBTSIT) vs. an endurance-based program alone (EBTAlone). The EBTSIT involved 10 SIT sessions over 4 weeks, in addition to 12 continuous exercise sessions, 2 anaerobic threshold exercise sessions, and 4 strength training sessions. The EBTAlone consisted of 20 continuous, 6 anaerobic threshold, 2 interval exercise sessions, and 8 strength training sessions. Time-trial performance (2,000-m erg performance) improved with EBTSIT (baseline = 414.6 ± 18.5, post = 410.6 ± 17.5 seconds; p < 0.001) but only approached significance in EBTAlone (baseline = 413.0 ± 27.7, post = 411.4 ± 27.9 seconds; p = 0.06). In a 60-second "all-out" anaerobic capacity test, peak power output (PPO) increased significantly with EBTSIT (PPO: EBTSIT: baseline = 566 ± 82, post = 623 ± 60 W; p = 0.02) but not with EBTAlone (EBTAlone: baseline = 603 ± 81, post = 591 ± 123 W; p = 0.59). Changes in average power output (APO) also approached significance (p = 0.07) (APO: EBTSIT: baseline = 508 ± 48, post = 530 ± 52 W; EBTAlone: baseline = 532 ± 55, post = 533 ± 68 W). Neither group experienced any change in aerobic capacity ((Equation is included in full-text article.)or ventilatory threshold; p ≥ 0.16). We conclude that replacing a portion of EBT with SIT can improve both 2,000-m erg performance and anaerobic capacity, while maintaining aerobic fitness in trained oarsmen. Incorporating SIT within endurance training programs may be useful during periods of low-volume training, to improve performance without sacrificing aerobic capacity.

  20. The acute effects of a caffeine-containing supplement on strength, muscular endurance, and anaerobic capabilities.

    PubMed

    Beck, Travis W; Housh, Terry J; Schmidt, Richard J; Johnson, Glen O; Housh, Dona J; Coburn, Jared W; Malek, Moh H

    2006-08-01

    The purpose of this study was to examine the acute effects of a caffeine-containing supplement on upper- and lower-body strength and muscular endurance as well as anaerobic capabilities. Thirty-seven resistance-trained men (mean +/- SD, age: 21 +/- 2 years) volunteered to participate in this study. On the first laboratory visit, the subjects performed 2 Wingate Anaerobic Tests (WAnTs) to determine peak power (PP) and mean power (MP), as well as tests for 1 repetition maximum (1RM), dynamic constant external resistance strength, and muscular endurance (TOTV; total volume of weight lifted during an endurance test with 80% of the 1RM) on the bilateral leg extension (LE) and free-weight bench press (BP) exercises. Following a minimum of 48 hours of rest, the subjects returned to the laboratory for the second testing session and were randomly assigned to 1 of 2 groups: a supplement group (SUPP; n = 17), which ingested a caffeine-containing supplement, or a placebo group (PLAC; n = 20), which ingested a cellulose placebo. One hour after ingesting either the caffeine-containing supplement or the placebo, the subjects performed 2 WAnTs and were tested for 1RM strength and muscular endurance on the LE and BP exercises. The results indicated that there was a significant (p < 0.05) increase in BP 1RM for the SUPP group, but not for the PLAC group. The caffeine-containing supplement had no effect, however, on LE 1RM, LE TOTV, BP TOTV, PP, and MP. Thus, the caffeine-containing supplement may be an effective supplement for increasing upper-body strength and, therefore, could be useful for competitive and recreational athletes who perform resistance training.

  1. Anaerobic capacity of the upper arms in top-level team handball players.

    PubMed

    Kounalakis, Stylianos N; Bayios, Ioannis A; Koskolou, Maria D; Geladas, Nickos D

    2008-09-01

    Handball is a sport with high anaerobic demands in lower body as has been indicated by Wingate test (WT) performed with the legs, but there are no data available concerning power production during a WT performed with the arms in handball players (HndP). Therefore, the purpose of this study was to explore the arm anaerobic profile of HndP during a WT. Twenty-one elite HndP and 9 physical education students (CON), performed a 30-s arm WT. Power production and muscle oxygenation were recorded. Peak power (PP) as well as mean power (MP) was higher (P = .017 and 0.03, and ES = 1.00 and 0.86, respectively) for HndP (HndP PP: 7.6 +/- 0.8 W x kg(-1); CON PP: 6.7 +/- 1.1 W x kg(-1); HndP MP 5.3 +/- 0.6 W x kg(-1); CON MP 4.7 +/- 0.9 W x kg(-1)) with no significant difference in fatigue index between the two groups. Muscle oxygen saturation (StO2) declined approximately 30% with exercise with no differences between groups. During recovery the HndP group had higher StO2 (P = .01, ES= 3.04), total hemoglobin and oxygenated hemoglobin compared with the CON group (P < .01 ES = 3.29 and 0.99, respectively). StO2 returned to resting values in 29.5 +/- 2.3 s in HndP, whereas this variable did not recover after 2 min in CON. The arm anaerobic capacity of the HndP was "excellent," significantly higher than that by the control group. Moreover, HndP exhibited faster recovery of StO2 compared with the control group. The greater power output and the faster muscle reoxygenation of arms in HndP can be attributed to specific training adaptations related to high performance in handball.

  2. Acute Effects of Three Different Stretching Protocols on the Wingate Test Performance

    PubMed Central

    Franco, Bruno L.; Signorelli, Gabriel R.; Trajano, Gabriel S.; Costa, Pablo B.; de Oliveira, Carlos G.

    2012-01-01

    The purpose of this study was to examine the acute effects of different stretching exercises on the performance of the traditional Wingate test (WT). Fifteen male participants performed five WT; one for familiarization (FT), and the remaining four after no stretching (NS), static stretching (SS), dynamic stretching (DS), and proprioceptive neuromuscular facilitation (PNF). Stretches were targeted for the hamstrings, quadriceps, and calf muscles. Peak power (PP), mean power (MP), and the time to reach PP (TP) were calculated. The MP was significantly lower when comparing the DS (7.7 ± 0.9 W/kg) to the PNF (7.3 ± 0.9 W/kg) condition (p < 0.05). For PP, significant differences were observed between more comparisons, with PNF stretching providing the lowest result. A consistent increase of TP was observed after all stretching exercises when compared to NS. The results suggest the type of stretching, or no stretching, should be considered by those who seek higher performance and practice sports that use maximal anaerobic power. Key points The mean power was significantly lower when comparing dynamic stretching.to proprioceptive neuromuscular facilitation. For peak power, significant differences were observed between more comparisons, with proprioceptive neuromuscular facilitation stretching providing the lowest result. A consistent increase of time to reach the peak was observed after all stretching exercises when compared to non-stretching. The type of stretching, or no stretching, should be considered by those who seek higher performance and practice sports that use maximal anaerobic power. PMID:24149116

  3. Aerobic power and lean mass are indicators of competitive sprint performance among elite female cross-country skiers.

    PubMed

    Carlsson, Tomas; Tonkonogi, Michail; Carlsson, Magnus

    2016-01-01

    The purpose of this study was to establish the optimal allometric models to predict International Ski Federation's ski-ranking points for sprint competitions (FISsprint) among elite female cross-country skiers based on maximal oxygen uptake ( [Formula: see text]) and lean mass (LM). Ten elite female cross-country skiers (age: 24.5±2.8 years [mean ± SD]) completed a treadmill roller-skiing test to determine [Formula: see text] (ie, aerobic power) using the diagonal stride technique, whereas LM (ie, a surrogate indicator of anaerobic capacity) was determined by dual-emission X-ray anthropometry. The subjects' FISsprint were used as competitive performance measures. Power function modeling was used to predict the skiers' FISsprint based on [Formula: see text], LM, and body mass. The subjects' test and performance data were as follows: [Formula: see text], 4.0±0.3 L min -1 ; LM, 48.9±4.4 kg; body mass, 64.0±5.2 kg; and FISsprint, 116.4±59.6 points. The following power function models were established for the prediction of FISsprint: [Formula: see text] and 6.95 × 10 10 · LM -5.25 ; these models explained 66% ( P =0.0043) and 52% ( P =0.019), respectively, of the variance in the FISsprint. Body mass failed to contribute to both models; hence, the models are based on [Formula: see text] and LM expressed absolutely. The results demonstrate that the physiological variables that reflect aerobic power and anaerobic capacity are important indicators of competitive sprint performance among elite female skiers. To accurately indicate performance capability among elite female skiers, the presented power function models should be used. Skiers whose [Formula: see text] differs by 1% will differ in their FISsprint by 5.8%, whereas the corresponding 1% difference in LM is related to an FISsprint difference of 5.1%, where both differences are in favor of the skier with higher [Formula: see text] or LM. It is recommended that coaches use the absolute expression of these variables to monitor skiers' performance-related training adaptations linked to changes in aerobic power and anaerobic capacity.

  4. Force production in the rugby union scrum.

    PubMed

    Quarrie, K L; Wilson, B D

    2000-04-01

    In this study, we examined the relationship between anthropometric, strength and power characteristics of rugby forwards, their body position when scrummaging, and their ability to apply force when scrummaging. Force applied to an instrumented scrum machine was measured for 56 players, both individually and as scrum packs. Measurements of body position for individuals were made by digitizing videotape records of the trials. Forty players subsequently had their anthropometry assessed and completed several strength and power tests. Body mass, each component of somatotype, maximal anaerobic power developed on a cycle ergometer, and isokinetic knee extension strength correlated significantly with individual scrummaging force. A regression model (P < 0.001) including body mass, mesomorphy, maximal anaerobic power and hip angle while in the scrummaging position accounted for 45% of the variance in individual scrummaging force. The packs that produced the largest scrummaging forces were, in general, characterized by a greater pack force to sum of individual force ratio than the packs producing lower forces. Our results emphasize the need for a scrum pack to develop technique and coordination as a unit to maximize scrummaging force.

  5. Dry anaerobic digestion of cow manure and agricultural products in a full-scale plant: Efficiency and comparison with wet fermentation.

    PubMed

    Chiumenti, Alessandro; da Borso, Francesco; Limina, Sonia

    2018-01-01

    For years, anaerobic digestion processes have been implemented for the management of organic wastes, agricultural residues, and animal manure. Wet anaerobic digestion still represents the most common technology, while dry fermentation, dedicated to the treatment of solid inputs (TS>20%) can be considered as an emerging technology, not in terms of technological maturity, but of diffusion. The first agricultural dry anaerobic digestion plant constructed in Italy was monitored from the start-up, for over a year. The plant was fed with manure and agricultural products, such as corn silage, triticale, ryegrass, alfalfa, and straw. Three Combined Heat and Power units, for a total installed power of 910kW e , converted biogas into thermal and electric energy. The monitoring included the determination of quality and quantity of input feedstocks, of digestate (including recirculation rate), of leachate, biogas quality (CH 4 , CO 2 , H 2 S), biogas yield, energy production, labor requirement for loading, and unloading operations. The results of the monitoring were compared to performance data obtained in several full scale wet digestion plants. The dry fermentation plant revealed a start-up phase that lasted several months, during which the average power resulted in 641kW e (70.4% of nominal power), and the last period the power resulted in 788kW e (86.6% of installed power). Improving the balance of the input, the dry fermentation process demonstrated biogas yields similar to wet anaerobic digestion, congruent to the energy potential of the biomasses used in the process. Furthermore, the operation of the plant required significant man labor, mainly related to loading and unloading of the anaerobic cells. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Short-duration beta-alanine supplementation increases training volume and reduces subjective feelings of fatigue in college football players.

    PubMed

    Hoffman, Jay R; Ratamess, Nicholas A; Faigenbaum, Avery D; Ross, Ryan; Kang, Jie; Stout, Jeffrey R; Wise, John A

    2008-01-01

    The purpose of this study was to examine the effect of 30 days of beta-alanine supplementation in collegiate football players on anaerobic performance measures. Subjects were randomly divided into a supplement (beta-alanine group [BA], 4.5 g x d(-1) of beta-alanine) or placebo (placebo group [P], 4.5 g x d(-1) of maltodextrin) group. Supplementation began 3 weeks before preseason football training camp and continued for an additional 9 days during camp. Performance measures included a 60-second Wingate anaerobic power test and 3 line drills (200-yd shuttle runs with a 2-minute rest between sprints) assessed on day 1 of training camp. Training logs recorded resistance training volumes, and subjects completed questionnaires on subjective feelings of soreness, fatigue, and practice intensity. No difference was seen in fatigue rate in the line drill, but a trend (P = .07) was observed for a lower fatigue rate for BA compared with P during the Wingate anaerobic power test. A significantly higher training volume was seen for BA in the bench press exercise, and a trend (P = .09) for a greater training volume was seen for all resistance exercise sessions. In addition, subjective feelings of fatigue were significantly lower for BA than P. In conclusion, despite a trend toward lower fatigue rates during 60 seconds of maximal exercise, 3 weeks of beta-alanine supplementation did not result in significant improvements in fatigue rates during high-intensity anaerobic exercise. However, higher training volumes and lower subjective feelings of fatigue in BA indicated that as duration of supplementation continued, the efficacy of beta-alanine supplementation in highly trained athletes became apparent.

  7. Individual anaerobic threshold estimates maximal lactate steady state in temperate and hot climate.

    PubMed

    De Barros, Cristiano L Monteiro; Mendes, Thiago T; Mortimer, Lucas De Ávila Castro Fleury; Ramos, Guilherme Passos; Garcia, Emerson Silami

    2016-01-01

    The aim of the present study was to compare the power output at the maximal lactate steady state (MLSS) with the power output at the individual anaerobic threshold (IAT) and at the onset of blood lactate accumulation (OBLA) in both temperate (TEMP) (22 °C) and hot (HOT) (40 °C) climates. Eight young active male (23.9±2.4 yr, 75.9±7.3 kg and 47.8±4.9 mL/kg/min) were evaluated on a cycle ergometer and performed a progressive exercise test until fatigue to determine the IAT and OBLA and two to five 30-min exercise tests at constant intensities for determine MLSS at both temperatures. An ANOVA with repeated measures and Dunnett's post-hoc test was performed to compare results of IAT and OBLA to the variables at the MLSS in both climates with MLSS being considered as the standard. At TEMP there was no difference between the power output at MLSS and IAT (180±11 W and 182±13 W, respectively), however, the intensity of the OBLA (154±11 W) was lower than MLSS (P<0.05). At HOT there was no difference between the power output at MLSS, IAT, and OBLA (148±11 W, 155±12 W and 144±11 W, respectively). These results showed that IAT is sensitive enough to estimate MLSS in both TEMP and HOT climate.

  8. Creatine co-ingestion with carbohydrate or cinnamon extract provides no added benefit to anaerobic performance.

    PubMed

    Islam, Hashim; Yorgason, Nick J; Hazell, Tom J

    2016-09-01

    The insulin response following carbohydrate ingestion enhances creatine transport into muscle. Cinnamon extract is promoted to have insulin-like effects, therefore this study examined if creatine co-ingestion with carbohydrates or cinnamon extract improved anaerobic capacity, muscular strength, and muscular endurance. Active young males (n = 25; 23.7 ± 2.5 y) were stratified into 3 groups: (1) creatine only (CRE); (2) creatine+ 70 g carbohydrate (CHO); or (3) creatine+ 500 mg cinnamon extract (CIN), based on anaerobic capacity (peak power·kg(-1)) and muscular strength at baseline. Three weeks of supplementation consisted of a 5 d loading phase (20 g/d) and a 16 d maintenance phase (5 g/d). Pre- and post-supplementation measures included a 30-s Wingate and a 30-s maximal running test (on a self-propelled treadmill) for anaerobic capacity. Muscular strength was measured as the one-repetition maximum 1-RM for chest, back, quadriceps, hamstrings, and leg press. Additional sets of the number of repetitions performed at 60% 1-RM until fatigue measured muscular endurance. All three groups significantly improved Wingate relative peak power (CRE: 15.4% P = .004; CHO: 14.6% P = .004; CIN: 15.7%, P = .003), and muscular strength for chest (CRE: 6.6% P < .001; CHO: 6.7% P < .001; CIN: 6.4% P < .001), back (CRE: 5.8% P < .001; CHO: 6.4% P < .001; CIN: 8.1% P < .001), and leg press (CRE: 11.7% P = .013; CHO: 10.0% P = .007; CIN: 17.3% P < .001). Only the CRE (10.4%, P = .021) and CIN (15.5%, P < .001) group improved total muscular endurance. No differences existed between groups post-supplementation. These findings demonstrate that three different methods of creatine ingestion lead to similar changes in anaerobic power, strength, and endurance.

  9. ENERGY PRODUCTION AND POLLUTION PREVENTION AT SEWAGE TREATMENT PLANTS USING FUEL CELL POWER PLANTS

    EPA Science Inventory

    The paper discusses energy production and pollution prevention at sewage treatment plants using fuel cell power plants. Anaerobic digester gas (ADG) is produced at waste water treatment plants during the anaerobic treatment of sewage to reduce solids. The major constituents are...

  10. Physiological pattern changes in response to a simulated competition in elite women artistic gymnasts.

    PubMed

    Isacco, Laurie; Ennequin, Gaël; Cassirame, Johan; Tordi, Nicolas

    2017-08-04

    The outstanding progress in women's artistic gymnastics in recent decades has led to increased technical and physiological demands. The aim of this study was to investigate i) the physiological demands of elite French gymnasts and ii) the impact of a competitive routine on physiological pattern changes. Fourteen French elite female gymnasts performed anthropometric measurements, physical fitness tests and a simulated four event competition. Heart rate (HR) was continuously recorded throughout the duration of the simulated competition. Blood lactate concentrations were assessed at rest, before the beginning and at 2, 4 and 10 min after completion of the routine on each apparatus. Isometric handgrip strength and anaerobic endurance and power were assessed during the simulated competition. The highest values of HR and blood lactate concentrations were reached during the floor and uneven bar exercises. Blood lactate concentrations and HR kinetics were apparatus dependent and values remained significantly increased at 10 min of recovery compared with resting data. Anaerobic endurance and power decreased significantly as the competition progressed (P <0.001). The present results show specifically cardiorespiratory and anaerobic apparatus- dependent responses throughout a simulated competition. Recovery approaches appear relevant to prevent and/or minimize fatigue and optimize performance in these athletes.

  11. Bioelectricity generation in microbial fuel cell using natural microflora and isolated pure culture bacteria from anaerobic palm oil mill effluent sludge.

    PubMed

    Nor, Muhamad Hanif Md; Mubarak, Mohd Fahmi Muhammad; Elmi, Hassan Sh Abdirahman; Ibrahim, Norahim; Wahab, Mohd Firdaus Abdul; Ibrahim, Zaharah

    2015-08-01

    A double-chambered membrane microbial fuel cell (MFC) was constructed to investigate the potential use of natural microflora anaerobic palm oil mill effluent (POME) sludge and pure culture bacteria isolated from anaerobic POME sludge as inoculum for electricity generation. Sterilized final discharge POME was used as the substrate with no addition of nutrients. MFC operation using natural microflora anaerobic POME sludge showed a maximum power density and current density of 85.11mW/m(2) and 91.12mA/m(2) respectively. Bacterial identification using 16S rRNA analysis of the pure culture isolated from the biofilm on the anode MFC was identified as Pseudomonas aeruginosa strain ZH1. The electricity generated in MFC using P. aeruginosa strain ZH1 showed maximum power density and current density of 451.26mW/m(2) and 654.90mA/m(2) respectively which were five times higher in power density and seven times higher in current density compared to that of MFC using anaerobic POME sludge. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Anaerobic metabolism during short all-out efforts in tethered running: Comparison of energy expenditure and mechanical parameters between different sprint durations for testing.

    PubMed

    Sousa, Filipe Antônio Barros; Vasque, Rubens Eduardo; Gobatto, Claudio Alexandre

    2017-01-01

    This study's aims to verify the energy expenditure, metabolic distress and usefulness to evaluate the anaerobic constructs for different all-out durations in running efforts. Twelve active male underwent four testing sessions, one for familiarization and three performing one all-out (AO) tethered running sprint lasting 30s, 20s or 10s. Oxygen consumption, excess post exercise oxygen consumption, and lactate production were retained to analyse metabolic function, together with mechanical power and work as performance parameters. Paired results were compared via one-way ANOVA for repeated measures (Tukey-HSD post-hoc), effect sizes and ICC for absolute agreement. Statistical significance was accepted at p ≤ 0.05. Despite total and energy expenditure from oxidative pathway being significantly higher for longer durations (p < 0.001; ES > 0.7), glycolytic energy expenditure presented an agreement between AO30s and AO20s (ICC-A = 0.63*), while the paired comparisons to AO10s have presented significant differences (p < 0.01; ES > 1.0). Phosphagen energy expenditure were similar between all-out durations (p = 0.12; ICC-A = 0.62*; ES < 0.5). Maximum mechanical power was higher in AO10s than in AO30s (p = 0.03; ES = 0.6), not being different between AO10s and AO20s (p = 0.67; ICC-A = 0.88*; ES = 0.2) and between AO20s and AO30s (p = 0.18; ICC-A = 0.56*; ES = 0.4). In addition, agreement between work in the first ten seconds was confirmed via ICC only between AO10s and AO20s (p = 0.50; ICC-A = 0.86*; ES = 0.3), but not for the other paired comparisons (p < 0.1; ICC < 0.45; ES > 0.5). AO20s is a better alternative to estimate anaerobic power and capacity in one single test, with similar oxidative demand than AO30s.

  13. Evaluation of various organic fertilizer substrates and hydraulic retention times for enhancing anaerobic degradation of explosives-contaminated groundwater while using constructed wetlands at the Milan Army Ammunition Plant, Milan, Tennessee. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behrends, L.L.; Almond, R.A.; Kelly, D.A.

    1998-05-01

    This document describes studies conducted at the Milan Army Ammunition Plant (MAAP) to improve the design, operation, and cost of gravel-based anaerobic cells when phytoremediating explosives-contaminated groundwater. To conduct this study, small-scale anaerobic test cells were used to determine: (1) If the hydraulic retention time of a large demonstration-scale anaerobic cell at MAAP could be reduced, and (2) if other carbon sources could be used as an anaerobic feedstock. The study results indicated that: (1) The existing anaerobic cell`s 7.5-day retention time should not be reduced since residual explosive by-products were present in the effluent of treatments with a 3.5-daymore » retention time. (2) Daily application of a relatively soluble substrate, such as molasses syrup, will provide better explosives removal than periodic application of less soluble substrates like milk replacement starter and sewage sludge. (3) Molasses syrup could be, and should be, used as a substitute for milk replacement power. The recommendation to use molasses syrup was based on: (1) The lower cost of molasses syrup as compared to milk replacement starter, (2) molasses syrup`s higher solubility (which makes it easier to apply), and (3) molasses syrup`s ability to provide enhanced explosives removal.« less

  14. Simulated front crawl swimming performance related to critical speed and critical power.

    PubMed

    Toussaint, H M; Wakayoshi, K; Hollander, A P; Ogita, F

    1998-01-01

    Competitive pool swimming events range in distance from 50 to 1500 m. Given the difference in performance times (+/- 23-1000 s), the contribution of the aerobic and anaerobic energy systems changes considerably with race distance. In training practice the regression line between swimming distance and time (Distance = critical velocity x time + anaerobic swimming capacity) is used to determine the individual capacity of the aerobic and anaerobic metabolic pathways. Although there is confidence that critical velocity and anaerobic swimming capacity are fitness measures that separate aerobic and anaerobic components, a firm theoretical basis for the interpretation of these results does not exist. The purpose of this study was to evaluate the critical power concept and anaerobic swimming capacity as measures of the aerobic and anaerobic capacity using a modeling approach. A systems model was developed that relates the mechanics and energetics involved in front crawl swimming performance. From actual swimming flume measurements, the time dependent aerobic and anaerobic energy release was modeled. Data derived from the literature were used to relate the energy cost of front crawl swimming to swimming velocity. A balance should exist between the energy cost to swim a distance in a certain time and the concomitant aerobic and anaerobic energy release. The ensuing model was used to predict performance times over a range of distances (50-1500 m) and to calculate the regression line between swimming distance and time. Using a sensitivity analysis, it was demonstrated that the critical velocity is indicative for the capacity of the aerobic energy system. Estimates of the anaerobic swimming capacity, however, were influenced by variations in both anaerobic and aerobic energy release. Therefore, it was concluded that the anaerobic swimming capacity does not provide a reliable estimate of the anaerobic capacity.

  15. Anaerobic power and muscle strength characteristics of 11 years old elite and non-elite boys and girls from gymnastics, team handball, tennis and swimming.

    PubMed

    Bencke, J; Damsgaard, R; Saekmose, A; Jørgensen, P; Jørgensen, K; Klausen, K

    2002-06-01

    The aim of the present investigation was to study the possible effects of specificity of training on muscle strength and anaerobic power in children from different sports and at different performance levels in relation to growth and maturation status. Hundred and eighty-four children of both gender participating either in swimming, tennis, team handball or gymnastics were recruited from the best clubs in Denmark. Within each sport, the coach had divided the children into an elite (E) and non-elite (NE) group according to performance level and talent. Tanner stage assessment and body weight and height measurements were performed by a physician. The anaerobic performances were assessed by Wingate tests and jumping performance in squat jump (SJ), countermovement jump (CMJ) and drop jump (DJ) from two heights. Most of the differences between groups in Wingate performance disappeared when the data were normalised to body mass. The gymnasts were the best jumpers and their superiority were increased in the more complex motor coordination tasks like DJ. The results may indicate some influence of training specificity, especially on the more complex motor tasks as DJ and there may be an effect of training before puberty. The performance in the less complex motor tasks like cycling and SJ and CMJ may also be influenced by specific training, but not to the same extent, and heritance may be an important factor for performance in these anaerobic tasks.

  16. Effect of Acute Effort on Isometric Strength and Body Balance: Trained vs. Untrained Paradigm.

    PubMed

    Sterkowicz, Stanisław; Jaworski, Janusz; Lech, Grzegorz; Pałka, Tomasz; Sterkowicz-Przybycień, Katarzyna; Bujas, Przemysław; Pięta, Paweł; Mościński, Zenon

    2016-01-01

    Years of training in competitive sports leads to human body adaptation to a specific type of exercise. In judo bouts, maintaining hand grip on an opponent's clothes and postural balance is essential for the effective technical and tactical actions. This study compares changes after maximal anaerobic exercise among judo athletes and untrained subjects regarding 1) maximum isometric handgrip strength (HGSmax) and accuracy at the perceived 50% maximum handgrip force (1/2HGSmax) and 2) the balance of 13 judo athletes at national (n = 8) and international (n = 5) competitive levels and 19 untrained university students. The groups did not differ in age, body height, and weight. Body mass index (BMI) and body composition (JAWON) were evaluated. The Wingate Anaerobic Test (WAnT, Monark 875E) measured recommended anaerobic capacity indices. Hand grip strength (Takei dynamometer) and balance (biplate balance platform) were measured before warm-up (T1), before the WAnT test (T2), and after (T3). Parametric or non-parametric tests were performed after verifying the variable distribution assumption. Judoists had higher BMI and fat-free mass index (FFMI) than the students. The athletes also showed higher relative total work and relative peak power and lower levels of lactic acid. The difference in judoists between HGSmax at T1 and HGSmax at T3 was statistically significant. Before warm-up (T1), athletes showed higher strength (more divergent from the calculated ½HGSmax value) compared to students. Substantial fatigue after the WAnT test significantly deteriorated the body stability indices, which were significantly better in judo athletes at all time points. The findings suggest specific body adaptations in judoists, especially for body composition, anaerobic energy system efficiency, and postural balance. These characteristics could be trained for specifically by judo athletes to meet the time-motion and anaerobic demands of contemporary bouts.

  17. Effect of Acute Effort on Isometric Strength and Body Balance: Trained vs. Untrained Paradigm

    PubMed Central

    Sterkowicz, Stanisław; Jaworski, Janusz; Lech, Grzegorz; Pałka, Tomasz; Sterkowicz-Przybycień, Katarzyna; Bujas, Przemysław; Pięta, Paweł; Mościński, Zenon

    2016-01-01

    Years of training in competitive sports leads to human body adaptation to a specific type of exercise. In judo bouts, maintaining hand grip on an opponent’s clothes and postural balance is essential for the effective technical and tactical actions. This study compares changes after maximal anaerobic exercise among judo athletes and untrained subjects regarding 1) maximum isometric handgrip strength (HGSmax) and accuracy at the perceived 50% maximum handgrip force (1/2HGSmax) and 2) the balance of 13 judo athletes at national (n = 8) and international (n = 5) competitive levels and 19 untrained university students. The groups did not differ in age, body height, and weight. Body mass index (BMI) and body composition (JAWON) were evaluated. The Wingate Anaerobic Test (WAnT, Monark 875E) measured recommended anaerobic capacity indices. Hand grip strength (Takei dynamometer) and balance (biplate balance platform) were measured before warm-up (T1), before the WAnT test (T2), and after (T3). Parametric or non-parametric tests were performed after verifying the variable distribution assumption. Judoists had higher BMI and fat-free mass index (FFMI) than the students. The athletes also showed higher relative total work and relative peak power and lower levels of lactic acid. The difference in judoists between HGSmax at T1 and HGSmax at T3 was statistically significant. Before warm-up (T1), athletes showed higher strength (more divergent from the calculated ½HGSmax value) compared to students. Substantial fatigue after the WAnT test significantly deteriorated the body stability indices, which were significantly better in judo athletes at all time points. The findings suggest specific body adaptations in judoists, especially for body composition, anaerobic energy system efficiency, and postural balance. These characteristics could be trained for specifically by judo athletes to meet the time-motion and anaerobic demands of contemporary bouts. PMID:27218258

  18. Computational fluid dynamics study on mixing mode and power consumption in anaerobic mono- and co-digestion.

    PubMed

    Zhang, Yuan; Yu, Guangren; Yu, Liang; Siddhu, Muhammad Abdul Hanan; Gao, Mengjiao; Abdeltawab, Ahmed A; Al-Deyab, Salem S; Chen, Xiaochun

    2016-03-01

    Computational fluid dynamics (CFD) was applied to investigate mixing mode and power consumption in anaerobic mono- and co-digestion. Cattle manure (CM) and corn stover (CS) were used as feedstock and stirred tank reactor (STR) was used as digester. Power numbers obtained by the CFD simulation were compared with those from the experimental correlation. Results showed that the standard k-ε model was more appropriate than other turbulence models. A new index, net power production instead of gas production, was proposed to optimize feedstock ratio for anaerobic co-digestion. Results showed that flow field and power consumption were significantly changed in co-digestion of CM and CS compared with those in mono-digestion of either CM or CS. For different mixing modes, the optimum feedstock ratio for co-digestion changed with net power production. The best option of CM/CS ratio for continuous mixing, intermittent mixing I, and intermittent mixing II were 1:1, 1:1 and 1:3, respectively. Copyright © 2016. Published by Elsevier Ltd.

  19. Physical and physiological characteristics in male team handball players by playing position - Does age matter?

    PubMed

    Nikolaidis, P T; Ingebrigtsen, J; Póvoas, S C; Moss, S; Torres-Luque, G

    2015-04-01

    The purpose of this study was to examine the variation in physical and physiological characteristics according to playing position in adolescent and adult male team handball (TH) players. Adolescent (N.=57, aged 14.9±1.4 yr) and adult (N.=39, 26.6±5.7 yr) players were examined for anthropometric characteristics, somatotype and body composition, and performed the physical working capacity test, a force-velocity test, the Wingate anaerobic test (WAnT), sit-and-reach test, handgrip strength test, squat jump (SJ), countermovement vertical jump without (CMJ) and with arm-swing, and a 30-s Bosco test. Eccentric utilization ratio (EUR) was calculated as the ratio CMJ to SJ. In adult players, there were significant differences between wings and the other positions with regard to anthropometric and body composition parameters (body mass, -17.9% to -13.2%; height, -5.3% to -4.3%; and fat-free mass, -13.7% to -9.9%) and anaerobic power assessed by WAnT (peak power, -20.5% to -15.2%; and mean power, -20% to -14.8%); however, these characteristics did not differ significantly in adolescents, in which the only statistically significant difference was found between goalkeepers and the other positions in EUR (+8.1%). Therefore, the differences in physical and physiological characteristics between playing positions are age-dependent. As adult players in this study were taken from players competing in the top Greek league, findings could serve as a base for talent identification and development for future studies. Moreover, knowledge about positional differences might enhance the ability to make tailored position-specific training programs among adult and adolescent players in the future.

  20. Effect of Vibration Training on Anaerobic Power and Quardroceps Surface EMG in Long Jumpers

    ERIC Educational Resources Information Center

    Liu, Bin; Luo, Jiong

    2015-01-01

    Objective: To explore the anaerobic power and surface EMG (sEMG) of quardrocep muscle in lower extremities after single vibration training intervention. Methods: 8 excellent male long jumpers voluntarily participated in this study. Four intervention modes were devised, including high frequency high amplitude (HFHA,30Hz,6mm), low frequency low…

  1. Menstrual Cycle Effects on Anaerobic Power, Muscular Strength, and Muscular Endurance in Trained and Untrained Females.

    ERIC Educational Resources Information Center

    Rosenburg, Beth S.; And Others

    A study determined if anaerobic power, isometric strength, and isometric endurance are affected by the menstrual cycle and if endurance trained females and untrained females are affected in the same manner on these performance parameters. Subjects were healthy, normally menstruating females, ages 18-34 years who were classified as either trained…

  2. A field test for determining the speed obtained through anaerobic glycolysis in runners.

    PubMed

    Borsetto, C; Ballarin, E; Casoni, I; Cellini, M; Vitiello, P; Conconi, F

    1989-10-01

    A field test for the evaluation of the speed generated by the anaerobic lactacid mechanism has been developed in runners. The test consists of 1200 m of continuous running: in the first 1000 m the speed corresponding to the anaerobic threshold is progressively reached; in the last 200 m an all-out sprint is performed. The speed at the anaerobic threshold is subtracted from the speed reached in the final 200-m all-out sprint. In 39 runners examined (marathon runners, n = 13; 5000-10000-m runners, n = 10; 400-800-m runners, n = 7; sprinters, n = 9), the additional speed generated above the anaerobic threshold was correlated with the venous blood lactate concentration reached 5 min after the all-out effort (r = 0.93). The anaerobic speeds measured by the test were in keeping with the characteristics of the runners under study, i.e., anaerobic speeds were highest for the sprinters, intermediate for the middle-distance runners, and lowest for the marathon runners. Since the speed generated above the anaerobic threshold by the aerobic fuel breakdown can be subtracted, the contribution of creatine phosphate is minimal, and the speed exceeding the anaerobic threshold is highly correlated with lactate accumulation, the present test should measure the speed generated by anaerobic glycolysis.

  3. Production and energetic use of biogas from energy crops and wastes in Germany.

    PubMed

    Weiland, Peter

    2003-01-01

    The production of biogas for reducing fossil CO2 emissions is one of the key strategic issues of the German government and has resulted in the development of new process techniques and new technologies for the energetic use of biogas. Progress has been made in cultivating energy crops for biogas production, in using new reactor systems for anaerobic digestion, and in applying more efficient technologies for combined heat and power production. Recently, integration of fuel cells within the anaerobic digestion process was started, and new technologies for biogas upgrading and conversion to hydrogen were tested. This article describes the trends in Germany for achieving more efficient energy production.

  4. Greater ankle strength, anaerobic and aerobic capacity, and agility predict Ground Combat Military Occupational School graduation in female Marines.

    PubMed

    Allison, Katelyn Fleishman; Keenan, Karen A; Wohleber, Meleesa F; Perlsweig, Katherine A; Pletcher, Erin R; Lovalekar, Mita; Beals, Kim; Coleman, Lawrence C; Nindl, Bradley C

    2017-11-01

    Women can serve in all military occupational specialties (MOS); however, musculoskeletal and physiological characteristics that predict successful completion of ground combat MOS schools by female Marines are unknown. To determine which demographic, musculoskeletal, and physiological characteristics predict graduation from infantry and vehicle ground combat MOS schools in female Marines. Prospective cohort study. Prior to MOS school, the following were assessed in 62 female Marines (22.0±3.0yrs, 163.9±5.8cm, 63.4±7.2kg): isokinetic shoulder, trunk, and knee and isometric ankle strength; body composition; anaerobic power (AP)/capacity (AC); maximal oxygen uptake (VO 2 max); and field-based fitness tests (broad jump, medicine ball throw, pro-agility). Both absolute and normalized (%body mass: %BM) values were utilized for strength, AP, AC, and VO 2 max. Select tests from each Marine's most recent Physical Fitness Test (PFT: abdominal crunches, 3-mile run time) and Combat Fitness Test (CFT: Maneuver Under Fire, Movement to Contact) were recorded. Participants were classified as graduated (N=46) or did not graduate (N=16). Simple logistic regression was performed to determine predictors of MOS school graduation. Statistical significance was set a priori at α=0.05. Absolute and normalized ankle inversion and eversion strength, normalized anaerobic capacity, absolute and normalized VO 2 max, right pro-agility, and PFT 3-mile run time significantly predicted MOS school graduation (p<0.05). Greater ankle strength, better agility, and greater anaerobic and aerobic capacity are important for successful completion of ground combat MOS school in female Marines. Prior to entering ground combat MOS school, it is recommended that female Marines should train to optimize these mobility-centric characteristics. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Effects of Deployment on Musculoskeletal and Physiological Characteristics and Balance.

    PubMed

    Nagai, Takashi; Abt, John P; Sell, Timothy C; Keenan, Karen A; McGrail, Mark A; Smalley, Brian W; Lephart, Scott M

    2016-09-01

    Despite many nonbattle injuries reported during deployment, few studies have been conducted to evaluate the effects of deployment on musculoskeletal and physiological characteristics and balance. A total of 35 active duty U.S. Army Soldiers participated in laboratory testing before and after deployment to Afghanistan. The following measures were obtained for each Soldier: shoulder, trunk, hip, knee, and ankle strength and range of motion (ROM), balance, body composition, aerobic capacity, and anaerobic power/capacity. Additionally, Soldiers were asked about their physical activity and load carriage. Paired t tests or Wilcoxon tests with an α = 0.05 set a priori were used for statistical analyses. Shoulder external rotation ROM, torso rotation ROM, ankle dorsiflexion ROM, torso rotation strength, and anaerobic power significantly increased following deployment (p < 0.05). Shoulder extension ROM, shoulder external rotation strength, and eyes-closed balance (p < 0.05) were significantly worse following deployment. The majority of Soldiers (85%) engaged in physical activity. In addition, 58% of Soldiers reported regularly carrying a load (22 kg average). The deployment-related changes in musculoskeletal and physiological characteristics and balance as well as physical activity and load carriage during deployment may assist with proper preparation with the intent to optimize tactical readiness and mitigate injury risk. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  6. Antimicrobial susceptibility of anaerobic bacteria in New Zealand: 1999-2003.

    PubMed

    Roberts, Sally A; Shore, Keith P; Paviour, Susan D; Holland, David; Morris, Arthur J

    2006-05-01

    Routine susceptibility testing of all anaerobic organisms is not advocated, but it is useful for laboratories to test periodically for anaerobic organisms and provide local susceptibility data to guide therapy. This study reports the national trend of antibiotic susceptibility of clinically significant anaerobes in New Zealand. Clinical isolates were tested using standardized methods against a range of antibiotics commonly used to treat anaerobic infections. Susceptibility was determined using NCCLS criteria. The change in susceptibility trends between this study and earlier studies was measured by comparing the geometric mean of the MIC. A total of 364 anaerobes were tested. Penicillin had poor activity against Bacteroides spp., Prevotella spp., Eubacterium spp., Clostridium tertium and Veillonella spp. In general, Fusobacterium spp., Bacteroides ureolyticus, Propionibacterium spp., Clostridium perfringens and anaerobic streptococci isolates, with the exception of Peptostreptococcus anaerobius, were penicillin susceptible. Amoxicillin/clavulanate showed good activity against most anaerobes, but resistance was seen with Bacteroides fragilis group and P. anaerobius isolates. Cefoxitin was more active than cefotetan, particularly against non-B. fragilis species, Eubacterium spp. and P. anaerobius. Meropenem and imipenem showed good activity against all anaerobes, with only 2 and 4% of Bacteroides spp., respectively, showing resistance. With the exception of Propionibacterium acnes isolates, which are predictably resistant, metronidazole was active against all anaerobes tested. There has been little change in susceptibility since 1997. Metronidazole, cefoxitin, piperacillin/tazobactam and amoxicillin/clavulanate remain good empirical choices when anaerobes are expected in our setting. No clinically relevant changes in susceptibility over time were found.

  7. The Association Between MCT1 T1470A Polymorphism and Power-Oriented Athletic Performance.

    PubMed

    Kikuchi, N; Fuku, N; Matsumoto, R; Matsumoto, S; Murakami, H; Miyachi, M; Nakazato, K

    2017-01-01

    The purpose of this study was to investigate the effects of the MCT1 T1470A polymorphism (rs1049434) on power-oriented performance and lactate concentration during or after cycling sprints in Japanese wrestlers. Participants (199 wrestlers and 649 controls) were genotyped for the MCT1 T1470A genotype (rs1049434) using the TaqMan ® Assay. All wrestlers were international (n=77) or national (n=122) level athletes. Among them, 46 wrestlers performed 2 anaerobic performance tests, a 30-s Wingate Anaerobic test (WAnT) and a series of 10 maximal effort 10-s sprints on a cycle ergometer. Blood lactate levels were measured before, during, and after the tests. In the A-allele recessive model (AA vs. TA+TT), the frequency of the AA genotype was significantly higher in all wrestlers than in controls (p=0.037). Wrestlers with AA genotype had lower blood lactate concentrations than those with TA+TT genotype at 10 min after the WAnT and following the 5 th and the final set of repeated cycling sprints (p<0.05). The AA genotype of the MCT1 T1470A polymorphism is over-represented in wrestlers compared with controls and is associated with lower blood lactate concentrations after 30-s WAnT and during intermittent sprint tests in Japanese wrestlers. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Aerobic Capacity and Anaerobic Power Levels of the University Students

    ERIC Educational Resources Information Center

    Taskin, Cengiz

    2016-01-01

    The aim of study was to analyze aerobic capacity and anaerobic power levels of the university students. Total forty university students who is department physical education and department business (age means; 21.15±1.46 years for male and age means; 20.55±1.79 years for female in department physical education), volunteered to participate in this…

  9. Intensification of anaerobic digestion efficiency with use of mechanical excess sludge disintegration in the context of increased energy production in wastewater treatment plants

    NASA Astrophysics Data System (ADS)

    Żubrowska-Sudoł, Monika; Podedworna, Jolanta; Bisak, Agnieszka; Sytek-Szmeichel, Katarzyna; Krawczyk, Piotr; Garlicka, Agnieszka

    2017-11-01

    The main goal of the study was to evaluate the effects of mechanical sludge disintegration for enhancing full scale anaerobic digestion of municipal sludge. Batch disintegration tests and lab dewatering tests were also performed aiming at determining the release of organic compounds and assessing the impact of disintegration of excess sludge before the fermentation process of mixed sludge on the dewaterability of post-fermented sludge, respectively. In the study a disc disintegrator driven by a motor with a power of 30 kW, revolutions n = 2950 rpm has been used. It was shown that with increase of energy consumed in the disintegration, the increased amounts of organic compounds were released from the sludge. It was also documented that the introduction of the excess sludge disintegration prior to fermentation tank, resulted in a significant increase in biogas production (by an average of 33.9%) and in increase in volatile total solids reduction in the fermented sludge (by an average of 22.7%). Moreover, the obtained results indicate the possibility of obtaining a higher degree of sludge dewatering, which was subjected to anaerobic stabilization with using disintegrated excess sludge.

  10. High Intensity Cycling Performances of Boys with and without Intellectual Disability.

    ERIC Educational Resources Information Center

    Chia, Y. H. M.; Lee, K. S.; Teo-Koh, S. M.

    2002-01-01

    Boys with (n=16) and without (n=18) intellectual disability (ID) performed the Wingate Anaerobic Test (WAnT) on two separate occasions. Comparable levels of reliability and agreement were found on the WAnT for both groups. However, the performances of boys with ID were more variable, less powerful, and resulted in lower post-exercise blood lactose…

  11. Anaerobic Biodegradation of Detergent Surfactants

    PubMed Central

    Merrettig-Bruns, Ute; Jelen, Erich

    2009-01-01

    Detergent surfactants can be found in wastewater in relevant concentrations. Most of them are known as ready degradable under aerobic conditions, as required by European legislation. Far fewer surfactants have been tested so far for biodegradability under anaerobic conditions. The natural environment is predominantly aerobic, but there are some environmental compartments such as river sediments, sub-surface soil layer and anaerobic sludge digesters of wastewater treatment plants which have strictly anaerobic conditions. This review gives an overview on anaerobic biodegradation processes, the methods for testing anaerobic biodegradability, and the anaerobic biodegradability of different detergent surfactant types (anionic, nonionic, cationic, amphoteric surfactants).

  12. Anthropometric characteristics and physical performance of colombian elite male wrestlers.

    PubMed

    Ramirez-Velez, Robinson; Argothyd, Rodrigo; Meneses-Echavez, Jose Francisco; Beatriz Sanchez-Puccini, Maria; Lopez-Alban, Carlos Alejandro; Cohen, Daniel Dylan

    2014-12-01

    Wrestling was an important part of the ancient Olympic Games and is still one of the most popular events of the modern Olympic Games. Studies indicate that general physiologic profile of successful wrestlers is high anaerobic power and capacity, muscular strength, above average aerobic power, exceptional flexibility, fat free mass, and a mesomorphic somatotype. The objective of the present study was to evaluate anthropometric characteristics and physical performance of elite male wrestlers. The Colombian Wrestling Team was evaluated while in preparation for the Olympic Games (n = 21; age, 27.9 ± 6.7 years). Athletes were tested on anthropometric and fitness parameters: body composition, somatotype distribution according to Heath-Carter, aerobic capacity, vertical jump, and anaerobic power. The evaluations showed a mean body fat percentage of 13.6% ± 3.0% (95% CI, 12.2%-15%), muscle mass of 46.4% ± 2.2% (95% CI, 45.4%-47.4%), Ponderal index of 41.0 ± 1.8 (95% CI, 40.2-41.8), body adiposity index (BAI) 25.1 ± 3.6 (95% CI, 23.5-26.8), and somatotype distribution mesomorphic-ectomorph (5.3-1.6-3.8). Mean aerobic capacity was 45.9 ± 6.6 mL/kg/min (95% CI, 42.8-48.9), vertical jump was 36.4 ± 6.6 cm (95% CI, 11.8-16.6), and anaerobic power was 92.6 ± 19.5 kg/s (95% CI, 83.7-101.5). These results provided a profile of elite wrestlers that could be used as training targets for developing athletes. The results may also provide information for training and tactical planning.

  13. Effects of oral ATP supplementation on anaerobic power and muscular strength.

    PubMed

    Jordan, Alexander N; Jurca, Radim; Abraham, Edward H; Salikhova, Anna; Mann, Julia K; Morss, Gina M; Church, Timothy S; Lucia, Alejandro; Earnest, Conrad P

    2004-06-01

    We examined 14 d of oral adenosine 5'-triphosphate (ATP) supplementation on indices of anaerobic capacity and muscular strength. Twenty-seven healthy males successfully completed the trial, after randomly receiving in a double-blind manner an oral dose of low dose (150 mg) or high dose (225 mg) ATP, or matched placebo. To improve absorption characteristics, the ATP was enterically coated. Total blood ATP (whole blood and plasma ATP) concentrations, two Wingate anaerobic power tests (30 s), and muscular strength (1RM and three sets of repetitions to fatigue at 70% of 1RM) were measured under three conditions: (i) baseline; (ii) acutely (7d later, no prior supplementation and 75 min after ATP ingestion); and (iii) after 14 d of daily ingestion (post). Statistical analyses showed no significant between or within group treatment effects for whole blood ATP or plasma ATP concentrations for any treatment condition. We also did not observe any treatment effects for any Wingate testing parameter including peak PO, total work, average PO for 30 s, or post-Wingate lactate accumulation. Overall, we observed no significant between group treatment effects for any muscular strength parameter. We did observe several within group differences for the group ingesting the high ATP dosage including 1RM (6.6%; P < 0.04) and repetitions to fatigue during set 1 of posttesting (18.5%; P < 0.007) and total lifting volume at post (22%; P < 0.003). We conclude that enterically coated oral ATP supplementation may provide small ergogenic effects on muscular strength under some treatment conditions.

  14. Intrinsic gas production kinetics of selected intermediates in anaerobic filters for demand-orientated energy supply.

    PubMed

    Krümpel, Johannes Hagen; Illi, Lukas; Lemmer, Andreas

    2018-03-01

    As a consequence of a growing share of solar and wind power, recent research on biogas production highlighted a need for demand-orientated, flexible gas production to provide grid services and enable a decentralized stabilization of the electricity infrastructure. Two-staged anaerobic digestion is particularly suitable for shifting the methane production into times of higher demand due to the spatio-temporal separation of hydrolysis and methanogenesis. To provide a basis for predicting gas production in an anaerobic filter, kinetic parameters of gas production have been determined experimentally in this study. A new methodology is used, enabling their determination during continuous operation. An order in methane production rate could be established by comparing the half lives of methane production. The order was beginning with the fastest: acetic acid>ethanol>butyric acid>iso-butyric acid>valeric acid>propionic acid>1,2propanediol>lactic acid. However, the mixture of a natural hydrolysate from the acidification tank appeared to produce methane faster than all single components tested.

  15. Lower limb alactic anaerobic power output assessed with different techniques in morbid obesity.

    PubMed

    Lafortuna, C L; Fumagalli, E; Vangeli, V; Sartorio, A

    2002-02-01

    Short-term alactic anaerobic performance in jumping (5 consecutive jumps with maximal effort), sprint running (8 m) and stair climbing (modified Margaria test) were measured in 75 obese subjects (BMI: 40.3+/-5.0 kg/m2) and in 36 lean control subjects (BMI: 22.4+/-3.2 kg/m2) of the same age and gender distribution. The results show that obese subjects attained a significantly lower specific (per unit body mass) power output both in jumping (W(spec,j); p<0.001) and stair climbing (W(spec,s); p<0.001) and run at a significantly lower average velocity (v; p<0.001) during sprinting. In spite of the different motor skillfulness required to accomplish the jumping and climbing tests, W(spec,s) (and hence the vertical velocity in climbing, v(v)) was closely correlated with W(spec,j) (R2=0.427, p<0.001). In jumping, although the average force during the positive work phase was significantly higher in obese subjects (p<0.001), no difference between the 2 groups was detected in absolute power. In stair climbing the absolute power output of obese resulted significantly higher (18%) than that of lean controls (p<0.001). In sprint running, the lower average horizontal velocity attained by obese subjects also entailed a different locomotion pattern with shorter step length (L(s); p<0.001), lower frequency (p<0.001) and longer foot contact time with ground (T(c,r); p<0.001). W(spec,j) seems to be a determinant of the poorer motor performance of obese, being significantly correlated with: I) the vertical displacement of the centre of gravity (R2=0.853, p<0.001) in jumping; II) with v(v) in stair climbing; and III) with T(c,r) (R2=0.492, p<0.001), L(s) (R2=0.266, p<0.001) and v (R2=0.454, p<0.001) in sprinting. The results suggest that obese individuals, although partially hampered in kinetic movements, largely rely on their effective specific power output to perform complex anaerobic tasks, and they suffer from the disproportionate excess of inert mass of fat. Furthermore, in view of the sedentary style of life and the consequent degree of muscle de-conditioning accompanying this condition, it may prove useful to implement rehabilitation programs for obesity with effective power training protocols.

  16. The effects of strength training on some parameters of aerobic and anaerobic endurance.

    PubMed

    Sentija, Davor; Marsić, Toso; Dizdar, Drazan

    2009-03-01

    The studies exploring the influence of resistance training on endurance in men have produced inconsistent results. The aim of this study was to examine the influence of an Olympic weight lifting training programme on parameters of aerobic and anaerobic endurance in moderately physically active men. Eleven physical education students (age: 24.1 +/- 1.8 yr, height: 1.77 +/- 0.04 m, body mass: 76.1 +/- 6.4 kg; X +/- SD) underwent a 12-week, 3 times/wk training programme of Olympic weight lifting. Specific exercises to master the lifting technique, and basic exercises for maximal strength and power development were applied, with load intensity and volume defined in relation to individual maximal load (repetitio maximalis, RM). Parameters of both, aerobic and anaerobic endurance were estimated from gas exchange data measured during a single incremental treadmill test to exhaustion, which was performed before, and after completion of the 12-wk programme. After training, there was a small, but significant increase in body mass (75.8 +/- 6.4 vs. 76.6 +/- 6.4, p < 0.05) and peak VO2 (54.9 +/- 5.4 vs. 56.4 +/- 5.3 mL O2/min/kg, p < 0.05), with no significant change of the running speed at the anaerobic threshold (V(AT)) and at exhaustion (V(max)) (both p > 0.05). However, there was a significant increase of anaerobic endurance, estimated from the distance run above V(AT), from V(AT) to V(max), (285 +/- 98 m vs 212 +/- 104 m, p < 0.01). The results of this study indicate that changes in both, anaerobic and aerobic endurance due to a 12-wk period of strength training in untrained persons can be determined from a single incremental treadmill test to exhaustion. The possible causes of those training effects include several possible mechanisms, linked primarily to peripheral adaptation.

  17. Electricity generation in single-chamber microbial fuel cells using a carbon source sampled from anaerobic reactors utilizing grass silage.

    PubMed

    Catal, Tunc; Cysneiros, Denise; O'Flaherty, Vincent; Leech, Dónal

    2011-01-01

    Production of electricity from samples obtained during anaerobic digestion of grass silage was examined using single-chamber air-cathode mediator-less microbial fuel cells (MFCs). The samples were obtained from anaerobic reactors at start-up conditions after 3 and 10 days of operation under psychrophilic (15 °C) and mesophilic (37 °C) temperatures. Electricity was directly produced from all samples at a concentration of 1500 mg CODL(-1). Power density obtained from the samples, as a sole carbon source, ranged from 56 ± 3 Wm(-3) to 31 ± 1 Wm(-3) for the mesophilic and psychrophilic samples, respectively. Coulombic efficiencies ranged from 18 ± 1% to 12 ± 1% for the same samples. The relationship between the maximum voltage output and initial COD concentration appeared to follow saturation kinetics at the external resistance of 217 Ω. Chemical oxygen demand (COD) removal was over 90% and total phenolics removal was in the range of 30-75% for all samples tested, with a standard amount of 60 mg L(-1) total phenolics removed for every sample. Our results indicate that generating electricity from solution samples of anaerobic reactors utilizing grass silage is possible, opening the possibility for combination of anaerobic digestion with MFC technology for energy generation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Alkaline treatment of high-solids sludge and its application to anaerobic digestion.

    PubMed

    Li, Chenchen; Li, Huan; Zhang, Yuyao

    2015-01-01

    High-solids anaerobic digestion is a promising new process for sludge reduction and bioenergy recovery, requiring smaller digestion tanks and less energy for heating, but a longer digestion time, than traditional low-solids anaerobic digestion. To accelerate this process, alkaline sludge disintegration was tested as a pretreatment method for anaerobic digestion of high-solids sludge. The results showed that alkaline treatment effectively disintegrated both low-solids sludge and high-solids sludge, and treatment duration of 30 min was the most efficient. The relation between sludge disintegration degree and NaOH dose can be described by a transmutative power function model. At NaOH dose lower than 0.2 mol/L, sludge disintegration degree remained virtually unchanged when sludge total solids (TS) content increased from 2.0 to 11.0%, and decreased only slightly when sludge TS increased to 14.2%. Although high-solids sludge required a slightly higher molarity of NaOH to reach the same disintegration level of low-solids sludge, the required mass of NaOH actually decreased due to sludge thickening. From the view of NaOH consumption, sludge TS of 8-12% and a NaOH dose of 0.05 mol/L were optimum conditions for alkaline pretreatment, which resulted in a slight increase in accumulative biogas yield, but a decrease by 24-29% in digestion time during the subsequent anaerobic digestion.

  19. Oxygen exposure promotes fuel diversity for Shewanella oneidensis microbial fuel cells.

    PubMed

    Biffinger, Justin C; Byrd, Jacqueline N; Dudley, Breanna L; Ringeisen, Bradley R

    2008-01-18

    Miniature microbial fuel cells (mini-MFCs) were used to monitor the current generated by Shewanella oneidensis DSP10 under both anaerobic and aerobic conditions when exposed to glucose as a potential electron donor. In addition to glucose, other carbon fuels including fructose, sucrose, acetate, and ascorbic acid were also tested. When the anolyte containing S. oneidensis was grown in the presence of oxygen, power densities of 270+/-10, 350+/-20, and 120+/-10 W/m(3) were recorded from the mini-MFC for glucose, fructose, and ascorbic acid electron donors, respectively, while sucrose and acetate produced no response. The power produced from glucose decreased considerably (

  20. 40 CFR 98.464 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... stream by either using at least a 60-day anaerobic biodegradation test as specified in paragraph (b)(4)(i... specified in paragraph (b)(4)(ii) of this section. (i) Perform an anaerobic biodegradation test and... standards organization to conduct a minimum of a 60-day anaerobic biodegradation test. Consensus-based...

  1. 40 CFR 98.464 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-day anaerobic biodegradation test as specified in paragraph (b)(4)(i) of this section or by estimating...) of this section. (i) Perform an anaerobic biodegradation test and determine the DOC value of a waste... minimum of a 60-day anaerobic biodegradation test. Consensus-based standards organizations include, but...

  2. Anthropometric Characteristics and Performance Capabilities of Highly Trained Motocross Athletes Compared With Physically Active Men.

    PubMed

    Bach, Christopher W; Brown, Ann F; Kinsey, Amber W; Ormsbee, Michael J

    2015-12-01

    Motocross (MX) is a physically demanding sport with little research concerning the physiological characteristics of these athletes. The purpose of this study was to assess the anthropometric characteristics and performance capabilities of highly trained MX athletes (n = 20; 19 ± 1.6 years) compared with age-matched physically active (PA) men (n = 22; 22 ± 2.9 years). Testing was performed on 2 occasions. The initial visit consisted of a personality assessment in addition to the following (in order): anthropometrics, body composition, anaerobic power/fatigue, isokinetic/isometric strength and fatigue, and flexibility. The second visit consisted of peak oxygen uptake (V[Combining Dot Above]O2peak), handgrip strength, maximum push-ups in 1 minute, extended arm hang time to exhaustion (TTE), and 90° weighted wall-sit tests. All anthropometric and performance data were analyzed using independent samples t-tests to compare group means. Significance was set at p ≤ 0.05. Data are reported as mean ± SD. There were no significant differences between groups in anthropometric or body composition measurements except android fat (MX: 11.7 ± 1.9% vs. PA: 16.4 ± 8.4%, p = 0.04) and biceps circumference (MX: 30.1 ± 2.0 vs. PA: 33.1 ± 3.2 cm, p = 0.001). MX had significantly higher absolute and relative mean anaerobic power (747.3 ± 63.7 vs. 679.7 ± 93.5 W, p = 0.009 and 10.0 ± 0.6 vs. 9.2 ± 1.3 W·kg, p = 0.002, respectively), relative anaerobic peak power (12.7 ± 0.8 vs. 11.9 ± 1.4 W·kg, p = 0.029), TTE (550.1 ± 70.6 vs. 470.1 ± 93.2 seconds, p = 0.004), and extended arm hang duration (113.3 ± 44.9 vs. 73.4 ± 25.3 seconds, p = 0.001). These results suggest highly trained MX athletes possess certain physiological adaptations that likely result from sport-specific demands compared with PA.

  3. Lack of concordance amongst measurements of individual anaerobic threshold and maximal lactate steady state on a cycle ergometer.

    PubMed

    Arratibel-Imaz, Iñaki; Calleja-González, Julio; Emparanza, Jose Ignacio; Terrados, Nicolas; Mjaanes, Jeffrey M; Ostojic, Sergej M

    2016-01-01

    The calculation of exertion intensity, in which a change is produced in the metabolic processes which provide the energy to maintain physical work, has been defined as the anaerobic threshold (AT). The direct calculation of maximal lactate steady state (MLSS) would require exertion intensities over a long period of time and with sufficient rest periods which would prove significantly difficult for daily practice. Many protocols have been used for the indirect calculation of MLSS. The aim of this study is to determine if the results of measurements with 12 different AT calculation methods and calculation software [Keul, Simon, Stegmann, Bunc, Dickhuth (TKM and WLa), Dmax, Freiburg, Geiger-Hille, Log-Log, Lactate Minimum] can be used interchangeably, including the method of the fixed threshold of Mader/OBLA's 4 mmol/l and then to compare them with the direct measurement of MLSS. There were two parts to this research. Phase 1: results from 162 exertion tests chosen at random from the 1560 tests. Phase 2: sixteen athletes (n = 16) carried out different tests on five consecutive days. There was very high concordance among all the methods [intraclass correlation coefficient (ICC) > 0.90], except Log-Log in relation to the Stegamnn, Dmax, Dickhuth-WLa and Geiger-Hille. The Dickhuth-TKM showed a high tendency towards concordance, with Dmax (2.2 W) and Dickhuth-WLa (0.1 W). The Dickhuth-TKM method presented a high tendency to concordance with Dickhuth-WLa (0.5 W), Freiburg (7.4 W), MLSS (2.0 W), Bunc (8.9 W), Dmax (0.1 W). The calculation of MLSS power showed a high tendency to concordance, with Dickhuth-TKM (2 W), Dmax (2.1 W), Dickhuth-WLa (1.5 W). The fixed threshold of 4 mmol/l or OBLA produces slightly different and higher results than those obtained with all the methods analyzed, including MLSS, meaning an overestimation of power in the individual anaerobic threshold. The Dickhuth-TKM, Dmax and Dickhuth-WLa methods defined a high concordance on a cycle ergometer. Dickhuth-TKM, Dmax, Dickhuth-WLa described a high concordance with the power calculated to know the MLSS.

  4. The Effect of Eight Weeks Plyometric Training on Anaerobic Power, Counter Movement Jumping and Isokinetic Strength in 15-18 Years Basketball Players

    ERIC Educational Resources Information Center

    Adigüzel, Niyazi Sidki; Günay, Mehmet

    2016-01-01

    The purpose of this study was to investigate the effect of eight weeks plyometric training on anaerobic power, counter movement jumping and isokinetic strength in 15-18 years aged basketball players. This study was including 30 male Basketball players. The subjects were divided into two groups as: the experimental group (n = 15) and the control…

  5. Municipal Development of Anaerobic Digestion/ Combined Heat and Power in Massachusetts

    NASA Astrophysics Data System (ADS)

    Pike, Brenda

    With a commercial food waste ban going into effect in Massachusetts in October 2014, businesses, institutions, and municipalities are considering alternatives to landfills and incinerators for organic waste. Anaerobic digestion is one such alternative. Similar to composting, but in an environment devoid of oxygen, anaerobic digestion produces byproducts such as methane (which can be burned for heat or electricity) and liquid or solid digestate (which can be used as fertilizer, cattle bedding, and more). Thus, disposal of food waste and other organic materials can become a source of revenue rather than just an expense. Municipalities interested in developing anaerobic digestion/combined heat and power (AD/CHP) facilities have the benefit of desirable options for sites, such as landfill gas facilities and wastewater treatment plants, and potential feedstocks in source-separated residential or municipal food waste or wastewater. This thesis examines the opportunities and challenges for municipal development of AD/CHP facilities in Massachusetts.

  6. Effect of a 10-week strength training program and recovery drink on body composition, muscular strength and endurance, and anaerobic power and capacity.

    PubMed

    Chromiak, Joseph A; Smedley, Brianne; Carpenter, William; Brown, Robert; Koh, Yun S; Lamberth, John G; Joe, Lee Ann; Abadie, Ben R; Altorfer, Greg

    2004-05-01

    We investigated whether postexercise consumption of a supplement containing whey protein, amino acids, creatine, and carbohydrate combined with a strength training program promotes greater gains in fat-free mass (FFM), muscle strength and endurance, and anaerobic performance compared with an isocaloric, carbohydrate-only control drink combined with strength training. The study was double blind and randomized, and the experimental supplement was compared with a carbohydrate-only control. Forty-one males (n = 20 in control group, n = 21 in the supplement group; mean age, 22.2 y) participated in a 4 d/wk, 10-wk periodized strength training program. Subjects had to complete at least 70% of the workouts. Before and after 10 wk of strength training, subjects were tested for body composition by using hydrostatic weighing and skinfold thicknesses, one repetition maximum strength and muscular endurance for the bench press and 45-degree leg press, and anaerobic performance using a 30-s Wingate test. Thirty-three subjects (80.5%) completed the training program (n = 15 in control group, n = 18 in the supplement); these 33 subjects also completed all post-training test procedures. Data were analyzed with two-way analysis of variance with repeated measures on time. P <== 0.05 was set as statistically significant. All statistical analyses, including calculation of effect size and power, were completed with SPSS 11.0. Across groups, FFM increased during 10 wk of strength training. Although there was no statistically significant time x group interaction for FFM, there was a trend toward a greater increase in FFM for the supplement group (+3.4 kg) compared with the control group (+1.5 kg; P = 0.077). The effect size (eta(2) = 0.100) was moderately large. Percentage of body fat declined and fat mass was unchanged; there were no differences between groups. One repetition maximum strength for the bench press and 45-degree leg press increased, but there were no differences between groups. Muscular endurance expressed as the number of repetitions completed with 85% of the one repetition maximum was unchanged; external work, which was estimated as repetitions completed x resistance used, increased for the 45-degree leg press but not for the bench press over the 10-wk training period; there were no time x group interactions for either measurement. Anaerobic power and capacity improved, but there were no differences between groups for these variables or for fatigue rate. Consumption of a recovery drink after strength training workouts did not promote greater gains in FFM compared with consumption of a carbohydrate-only drink; however, a trend toward a greater increase in FFM in the supplement group suggests the need for longer-term studies. Performance variables such as muscle strength and endurance and anaerobic performance were not improved when compared with the carbohydrate-only group.

  7. Comparison of spot esculin hydrolysis with the PathoTec strip test for rapid differentiation of anaerobic bacteria.

    PubMed Central

    Qadri, S M; Johnson, S; Smith, J C; Zubairi, S; Gillum, R L

    1981-01-01

    The ability of several anaerobic bacteria to hydrolyze esculin to esculetin is used by clinical microbiologists and taxonomists in the differentiation and identification of both gram-positive and gram-negative microorganisms. Conventional methods used for determining esculin hydrolysis by anaerobic bacteria require 24 to 48 h for completion. In this paper we evaluate two procedures which yield rapid results. A total of 738 anaerobic bacteria were used in this study. A total of 99% of the esculin-hydrolyzing anaerobic bacteria gave positive results with the spot test in 1 h, whereas the other test method, the PathoTec strip test (General Diagnostics, Morris Plains, N.J.), required 4 h for 96% of the strains tested to yield positive reactions. Both tests showed a 100% specificity when compared with the standard broth test and are easy to perform, accurate, and economical. The spot test is superior to the PathoTec strip test in yielding results more rapidly. PMID:7016896

  8. Enhancing Short-Term Recovery After High-Intensity Anaerobic Exercise.

    PubMed

    Al-Nawaiseh, Ali M; Pritchett, Robert C; Bishop, Philip A

    2016-02-01

    This study examined the effects of antioxidant vitamins, ibuprofen, cold water submersion, and whey protein administered simultaneously on short-term recovery. Competitive athletes (n = 22) performed the protocol in 2 occasions (treatment and control) separated by 15 days in counterbalanced crossover design. Each occasion consisted of morning and afternoon sessions (AM and PM). In each session, participants performed 2 bouts of high-intensity anaerobic cycling separated by 30 minutes of rest. Each bout consisted of 3 Wingate tests (3 × 30-second Wingate tests) with 3 minutes of active recovery in between. Power output, rated perceived exertion (RPE), and pain scores were averaged and compared between the 2 sessions (AM vs. PM) and between the treatment vs. control (4 bouts). Creatine kinase (CK) levels were also measured 24 hours after the AM bout. Power output, CK, muscle soreness, and RPE were measured as recovery indices. Creatine kinase increased (p < 0.001) in both treatment and control 24 hours after the AM session. Performance results in the PM session for treatment/control were 832.5 ± 198.7/813.3 ± 187.6 W for peak power (PP), and 497.85 ± 120.7/486.1 ± 115 W for mean power (MP). Treatment was effective in maintaining MP (p = 0.034) in the PM sessions, but there was no significant effect of treatment on PP (p = 0.193), CK (p = 0.08), pain (p = 0.12), or RPE (p = 0.45). Treatment was helpful in protecting performance, but this was apparently not due to reduced muscle soreness or damage.

  9. Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive

    NASA Technical Reports Server (NTRS)

    Hernandez, Alan; Hess, Daniel P.

    2016-01-01

    This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.

  10. [Effects of ß-alanine supplementation on wingate tests in university female footballers].

    PubMed

    Rodríguez Rodríguez, Fernando; Delgado Ormeño, Alex; Rivera Lobos, Patricio; Tapia Aranda, Víctor; Cristi-Montero, Carlos

    2014-11-01

    Football is a sport that develops actions intermittent high-intensity exercise using the anaerobic pathway, for that reason, the muscle fatigue would produce primarily by increasing acidosis. Carnosine, which is formed from L-histidine, ß-alanine, has proven to produce an effect "buffer" of acidosis. To determine the effect of ß-alanine supplementation, on three successive Wingate tests and compare the average power, maximum power and lactate blood in selected female college soccer. We evaluated 10 football players who were three Wingate, 5 min rest between each sprint, determining the average power, maximum and lactate at the end of each test, then consumed 2,4 gr/day of ß-alanine for 30 days and repeated the tests. The control group (n=8) performed the same tests, but without consuming the supplement. Monark cycle ergometer was used (Ergomedic 874E) and to measure lactate the Lactate Pro 2. The group with supplementation significantly improved mean power difference from the control group. The maximum power improved only in the first sprint unlike the control group and Lactate did not differ. The evidence shows that the ß-alanine improves performance on tests of more than 30 second long, but in our study improves average power and peak power even when performing consecutive sprint, being able to emulate the reality of the football game. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  11. Effects of Beetroot Juice Supplementation on a 30-s High-Intensity Inertial Cycle Ergometer Test

    PubMed Central

    Domínguez, Raul; Garnacho-Castaño, Manuel Vicente; Cuenca, Eduardo; García-Fernández, Pablo; Muñoz-González, Arturo; de Jesús, Fernando; Lozano-Estevan, María Del Carmen; Veiga-Herreros, Pablo

    2017-01-01

    Background: Beetroot juice (BJ) is rich in inorganic nitrates and has proved effective at increasing blood nitric oxide (NO) levels. When used as a supplement BJ has shown an ergogenic effect on cardiorespiratory resistance exercise modalities, yet few studies have examined its impact on high intensity efforts. Objective: To assess the effects of BJ intake on anaerobic performance in a Wingate test. Methods: Fifteen trained men (age 21.46 ± 1.72 years, height 1.78 ± 0.07 cm and weight 76.90 ± 8.67 kg) undertook a 30-s maximum intensity test on an inertial cycle ergometer after drinking 70 mL of BJ (5.6 mmol NO3−) or placebo. Results: Despite no impacts of BJ on the mean power recorded during the test, improvements were produced in peak power (6%) (p = 0.034), average power 0–15 s (6.7%) (p = 0.048) and final blood lactate levels (82.6%) (p < 0.001), and there was a trend towards a shorter time taken to attain peak power (−8.4%) (p = 0.055). Conclusions: Supplementation with BJ has an ergonomic effect on maximum power output and on average power during the first 15 s of a 30-s maximum intensity inertial cycle ergometer test. PMID:29244746

  12. Relationship between body composition, leg strength, anaerobic power, and on-ice skating performance in division I men's hockey athletes.

    PubMed

    Potteiger, Jeffrey A; Smith, Dean L; Maier, Mark L; Foster, Timothy S

    2010-07-01

    The purpose of this study was to examine relationships between laboratory tests and on-ice skating performance in division I men's hockey athletes. Twenty-one men (age 20.7 +/- 1.6 years) were assessed for body composition, isokinetic force production in the quadriceps and hamstring muscles, and anaerobic muscle power via the Wingate 30-second cycle ergometer test. Air displacement plethysmography was used to determine % body fat (%FAT), fat-free mass (FFM), and fat mass. Peak torque and total work during 10 maximal effort repetitions at 120 degrees .s were measured during concentric muscle actions using an isokinetic dynamometer. Muscle power was measured using a Monark cycle ergometer with resistance set at 7.5% of body mass. On-ice skating performance was measured during 6 timed 89-m sprints with subjects wearing full hockey equipment. First length skate (FLS) was 54 m, and total length skate (TLS) was 89 m with fastest and average skating times used in the analysis. Correlation coefficients were used to determine relationships between laboratory testing and on-ice performance. Subjects had a body mass of 88.8 +/- 7.8 kg and %FAT of 11.9 +/- 4.6. First length skate-Average and TLS-Average skating times were moderately correlated to %FAT ([r = 0.53; p = 0.013] and [r = 0.57; p = 0.007]) such that a greater %FAT was related to slower skating speeds. First length skate-Fastest was correlated to Wingate percent fatigue index (r = -0.48; p = 0.027) and FLS-Average was correlated to Wingate peak power per kilogram body mass (r = -0.43; p = 0.05). Laboratory testing of select variables can predict skating performance in ice hockey athletes. This information can be used to develop targeted and effective strength and conditioning programs that will improve on-ice skating speed.

  13. Effects of Sprint Interval Training With Active Recovery vs. Endurance Training on Aerobic and Anaerobic Power, Muscular Strength, and Sprint Ability.

    PubMed

    Sökmen, Bülent; Witchey, Ronald L; Adams, Gene M; Beam, William C

    2018-03-01

    Sökmen, B, Witchey, RL, Adams, GM, and Beam, WC. Effects of sprint interval training with active recovery vs. endurance training on aerobic and anaerobic power, muscular strength, and sprint ability. J Strength Cond Res 32(3): 624-631, 2018-This study compared sprint interval training with active recovery (SITAR) to moderate-intensity endurance training (ET) in aerobic and anaerobic power, muscular strength, and sprint time results. Forty-two recreationally active adults were randomly assigned to a SITAR or ET group. Both groups trained 3× per week for 10 weeks at 75% of V[Combining Dot Above]O2max for 30 minutes weeks 1-4, with duration increasing to 35 minutes weeks 5-7 and 40 minutes weeks 8-10. While ET ran on a 400-m track without rest for the full training session, SITAR sprinted until the 200-m mark and recovered with fast walking or light jogging the second 200 m to the finish line in 3× original sprint time. Maximal oxygen consumption (V[Combining Dot Above]O2max), anaerobic treadmill run to exhaustion at 12.5 km·h at 20% incline, isokinetic leg extension and flexion strength at 60 and 300°·s, and 50 m sprint time were determined before and after training. Results showed a significant improvement (p ≤ 0.05) in absolute and relative V[Combining Dot Above]O2max, anaerobic treadmill run, and sprint time in both groups. Only SITAR showed significant improvements in isokinetic leg extension and flexion at 300°·s and decreases in body mass (p ≤ 0.05). SITAR also showed significantly greater improvement (p ≤ 0.05) over ET in anaerobic treadmill run and 50 m sprint time. These data suggest that SITAR is a time-efficient strategy to induce rapid adaptations in V[Combining Dot Above]O2max comparable to ET with added improvements in anaerobic power, isokinetic strength, and sprint time not observed with ET.

  14. Do physiological measures predict selected CrossFit(®) benchmark performance?

    PubMed

    Butcher, Scotty J; Neyedly, Tyler J; Horvey, Karla J; Benko, Chad R

    2015-01-01

    CrossFit(®) is a new but extremely popular method of exercise training and competition that involves constantly varied functional movements performed at high intensity. Despite the popularity of this training method, the physiological determinants of CrossFit performance have not yet been reported. The purpose of this study was to determine whether physiological and/or muscle strength measures could predict performance on three common CrossFit "Workouts of the Day" (WODs). Fourteen CrossFit Open or Regional athletes completed, on separate days, the WODs "Grace" (30 clean and jerks for time), "Fran" (three rounds of thrusters and pull-ups for 21, 15, and nine repetitions), and "Cindy" (20 minutes of rounds of five pull-ups, ten push-ups, and 15 bodyweight squats), as well as the "CrossFit Total" (1 repetition max [1RM] back squat, overhead press, and deadlift), maximal oxygen consumption (VO2max), and Wingate anaerobic power/capacity testing. Performance of Grace and Fran was related to whole-body strength (CrossFit Total) (r=-0.88 and -0.65, respectively) and anaerobic threshold (r=-0.61 and -0.53, respectively); however, whole-body strength was the only variable to survive the prediction regression for both of these WODs (R (2)=0.77 and 0.42, respectively). There were no significant associations or predictors for Cindy. CrossFit benchmark WOD performance cannot be predicted by VO2max, Wingate power/capacity, or either respiratory compensation or anaerobic thresholds. Of the data measured, only whole-body strength can partially explain performance on Grace and Fran, although anaerobic threshold also exhibited association with performance. Along with their typical training, CrossFit athletes should likely ensure an adequate level of strength and aerobic endurance to optimize performance on at least some benchmark WODs.

  15. Influence of diligent disintegration on anaerobic biomass and performance of microbial fuel cell.

    PubMed

    Divyalakshmi, Palanisamy; Murugan, Devaraj; Rai, Chockalingam Lajapathi

    2017-12-01

    To enhance the performance of microbial fuel cells (MFC) by increasing the surface area of cathode and diligent mechanical disintegration of anaerobic biomass. Tannery effluent and anaerobic biomass were used. The increase in surface area of the cathode resulted in 78% COD removal, with the potential, current density, power density and coulombic efficiency of 675 mV, 147 mA m -2 , 33 mW m -2 and 3.5%, respectively. The work coupled with increased surface area of the cathode with diligent mechanical disintegration of the biomass, led to a further increase in COD removal of 82% with the potential, current density, power density and coulombic efficiency of 748 mV, 229 mA m -2 , 78 mW m -2 and 6% respectively. Mechanical disintegration of the biomass along with increased surface area of cathode enhances power generation in vertical MFC reactors using tannery effluent as fuel.

  16. [First Argentine consensus guidelines for in vitro antimicrobial susceptibility testing of clinically relevant anaerobic bacteria in humans/ Anaerobic Subcommittee of the Asociación Argentina de Microbiología].

    PubMed

    Legaria, María C; Bianchini, Hebe M; Castello, Liliana; Carloni, Graciela; Di Martino, Ana; Fernández Canigia, Liliana; Litterio, Mirta; Rollet, Raquel; Rossetti, Adelaida; Predari, Silvia C

    2011-01-01

    Through time, anaerobic bacteria have shown good susceptibility to clinically useful antianaerobic agents. Nevertheless, the antimicrobial resistance profile of most of the anaerobic species related to severe infections in humans has been modified in the last years and different kinds of resistance to the most active agents have emerged, making their effectiveness less predictable. With the aim of finding an answer and for the purpose of facilitating the detection of anaerobic antimicrobial resistance, the Anaerobic Subcommittee of the Asociación Argentina de Microbiología developed the First Argentine consensus guidelines for in vitro antimicrobial susceptibility testing of clinically relevant anaerobic bacteria in humans. This document resulted from the compatibilization of the Clinical and Laboratory Standards Institute recommendations, the international literature and the work and experience of the Subcommittee. The Consensus document provides a brief taxonomy review, and exposes why and when anaerobic antimicrobial susceptibility tests should be conducted, and which antimicrobial agents can be used according to the species involved. The recommendations on how to perform, read and interpret in vitro anaerobic antimicrobial susceptibility tests with each method are exposed. Finally, the antibiotic susceptibility profile, the classification of antibiotics according to their in vitro activities, the natural and acquired mechanisms of resistance, the emerging resistance and the regional antibiotic resistance profile of clinically relevant anaerobic species are shown.

  17. Impact of body composition on performance in fitness tests among personnel of the Croatian navy.

    PubMed

    Sporis, Goran; Jukić, Igor; Bok, Daniel; Vuleta, Dinko; Harasin, Drazen

    2011-06-01

    The purpose of this study was to determine the impact of body weight on fitness tests among the personnel of the Croatian navy. Forty two naval personnel (age 27 +/- 4.1 years; body mass 86.2 +/- 4.9 kg; height 184.6 +/- 7.4 cm; body fat percentage 17.3 +/- 5.2) participated in this study. In order to evaluate the fitness of the naval servicemen, we applied a testing procedure that included measurements of 7 fitness tests and 15 body anthropometric tests. A negative correlation was found between the body fat percentage and all the analyzed sprint tests and three anaerobic power tests (r), SP5 (r = -0.42), SP10 (r = -0.51), SP20 (r = -0.53), SJ (r = -0.45), CM (r = -0.57), SLJ (r = -0.67). Also a negative correlation was found between the body fat percentage and VO2(max) (r = -0.44). A positive correlation was found between the sprint test and the power performance test and thigh and calf girth. Spiriting ability is influenced by the strength of a person. This is one of the reasons why we found a positive correlation between the sprint test (SP5, SP10 and SP20) and thigh and calf girth. In this study we found a negative correlation between body fat percentages and all the sprint tests and three anaerobic power tests and VO2(max). The ectomorph somatotypes have positive correlations with all variables. The mesomorph somatotypes have the greatest positive correlations with all variables. The endomorph somatotypes have negative correlations with all variables. According to the body composition of Croatian naval servicemen we can conclude that they need a sufficient level of strength and endurance for everyday tasks. The effectiveness of a weight-management program is determined by the success of the participants in losing the necessary amount of weight and being able to maintain that weight loss. This requires long-term tracking of these individuals in a naval environment.

  18. Muscle fibre conduction velocity during a 30-s Wingate anaerobic test.

    PubMed

    Stewart, David; Farina, Dario; Shen, Chao; Macaluso, Andrea

    2011-06-01

    Ten male volunteers (age 29.2 ± 5.2 years, mean ± SD) were recruited to test the hypothesis that muscle fibre conduction velocity (MFCV) would decrease with power output during a 30-s Wingate test on a mechanically-braked cycle ergometer. Prior to the main test, the optimal pre-fixed load corresponding to the highest power output was selected following a random series of six 10-s sprints. Surface electromyographic (EMG) signals were detected from the right vastus lateralis with linear adhesive arrays of eight electrodes. Power output decreased significantly from 6-s until the end of the test (860.9 ± 207.8 vs. 360.9 ± 11.4 W, respectively) and was correlated with MFCV (R=0.543, P<0.01), which also declined significantly by 26.8 ± 11% (P<0.05). There was a tendency for the mean frequency of the EMG power spectrum (MNF) to decrease, but average rectified values (ARV) remained unchanged throughout the test. The parallel decline of MFCV with power output suggests changes in fibre membrane properties. The unaltered ARV, together with the declined MFCV, would indicate either a decrease in discharge rate, de-recruitment of fatigued motor units or elongation of still present motor unit action potentials. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Ultrasound pre-treatment for anaerobic digestion improvement.

    PubMed

    Pérez-Elvira, S; Fdz-Polanco, M; Plaza, F I; Garralón, G; Fdz-Polanco, F

    2009-01-01

    Prior research indicates that ultrasounds can be used in batch reactors as pre-treatment before anaerobic digestion, but the specific energy required at laboratory-scale is too high. This work evaluates both the continuous ultrasound device performance (efficiency and solubilisation) and the operation of anaerobic digesters continuously fed with sonicated sludge, and presents energy balance considerations. The results of sludge solubilisation after the sonication treatment indicate that, applying identical specific energy, it is better to increase the power than the residence time. Working with secondary sludge, batch biodegradability tests show that by applying 30 kWh/m3 of sludge, it is possible to increase biogas production by 42%. Data from continuous pilot-scale anaerobic reactors (V=100 L) indicate that operating with a conventional HRT=20 d, a reactor fed with pre-treated sludge increases the volatile solids removal and the biogas production by 25 and 37% respectively. Operating with HRT=15 d, the removal efficiency is similar to the obtained with a reactor fed with non-hydrolysed sludge at HTR=20 d, although the specific biogas productivity per volume of reactor is higher for the pretreated sludge. Regarding the energy balance, although for laboratory-scale devices it is negative, full-scale suppliers state a net generation of 3-10 kW per kW of energy used.

  20. Determinants of a simulated cross-country skiing sprint competition using V2 skating technique on roller skis.

    PubMed

    Mikkola, Jussi; Laaksonen, Marko; Holmberg, Hans-Christer; Vesterinen, Ville; Nummela, Ari

    2010-04-01

    The present study investigated the performance-predicting factors of a simulated cross-country (XC) skiing sprint competition on roller skis, on a slow surface. Sixteen elite male XC skiers performed a simulated sprint competition (4 x 850 m heat with a 20-minute recovery) using V2 skating technique on an indoor tartan track. Heat velocities, oxygen consumption, and peak lactate were measured during or after the heats. Maximal skiing velocity was measured by performing a 30-m speed test. Explosive and maximal force production in the upper body was determined by bench press (BP). Subjects also performed maximal anaerobic skiing test (MAST) and the 2 x 2-km double poling (DP) test. The maximal velocity of MAST (VMAST) and velocities at 3 (V3), 5 (V5), 7 (V7) mmol.L lactate levels in MAST were determined. In the 2 x 2-km test, DP economy (VO2SUBDP) and maximal 2-km DP velocity (VDP2KM) were determined. The best single performance-predicting factors for the sprint performance were VDP2KM (r = 0.73, p < 0.01), V7 (r = 0.70, p < 0.01), and VO2SUBDP (r = -0.70, p < 0.01). Faster skiers in sprint simulation had a higher absolute VO2 (L.min) (p < 0.05-0.01) during sprint heats, and higher anaerobic skiing power (VMAST, p < 0.05) and better anaerobic skiing economy (V3, V5, V7, p < 0.05-0.001) than slower skiers. Faster skiers were also stronger in BP, with regard to both absolute (p < 0.01) and relative (p < 0.05) values. In addition, anaerobic characteristics seem to be of importance at the beginning of the XC skiing sprint competition, whereas the aerobic characteristics become more important as the XC skiing sprint competition progressed. This study indicates that sprint skiers should emphasize sport-specific upper body training, and training skiing economy at high speeds.

  1. Modelling anaerobic co-digestion in Benchmark Simulation Model No. 2: Parameter estimation, substrate characterisation and plant-wide integration.

    PubMed

    Arnell, Magnus; Astals, Sergi; Åmand, Linda; Batstone, Damien J; Jensen, Paul D; Jeppsson, Ulf

    2016-07-01

    Anaerobic co-digestion is an emerging practice at wastewater treatment plants (WWTPs) to improve the energy balance and integrate waste management. Modelling of co-digestion in a plant-wide WWTP model is a powerful tool to assess the impact of co-substrate selection and dose strategy on digester performance and plant-wide effects. A feasible procedure to characterise and fractionate co-substrates COD for the Benchmark Simulation Model No. 2 (BSM2) was developed. This procedure is also applicable for the Anaerobic Digestion Model No. 1 (ADM1). Long chain fatty acid inhibition was included in the ADM1 model to allow for realistic modelling of lipid rich co-substrates. Sensitivity analysis revealed that, apart from the biodegradable fraction of COD, protein and lipid fractions are the most important fractions for methane production and digester stability, with at least two major failure modes identified through principal component analysis (PCA). The model and procedure were tested on bio-methane potential (BMP) tests on three substrates, each rich on carbohydrates, proteins or lipids with good predictive capability in all three cases. This model was then applied to a plant-wide simulation study which confirmed the positive effects of co-digestion on methane production and total operational cost. Simulations also revealed the importance of limiting the protein load to the anaerobic digester to avoid ammonia inhibition in the digester and overloading of the nitrogen removal processes in the water train. In contrast, the digester can treat relatively high loads of lipid rich substrates without prolonged disturbances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Aerobic power and peak power of elite America's Cup sailors.

    PubMed

    Neville, Vernon; Pain, Matthew T G; Folland, Jonathan P

    2009-05-01

    Big-boat yacht racing is one of the only able bodied sporting activities where standing arm-cranking ('grinding') is the primary physical activity. However, the physiological capabilities of elite sailors for standing arm-cranking have been largely unreported. The purpose of the study was to assess aerobic parameters, VO(2peak) and onset of blood lactate (OBLA), and anaerobic performance, torque-crank velocity and power-crank velocity relationships and therefore peak power (P (max)) and optimum crank-velocity (omega(opt)), of America's Cup sailors during standing arm-cranking. Thirty-three elite professional sailors performed a step test to exhaustion, and a subset of ten grinders performed maximal 7 s isokinetic sprints at different crank velocities, using a standing arm-crank ergometer. VO(2peak) was 4.7 +/- 0.5 L/min (range 3.6-5.5 L/min) at a power output of 332 +/- 44 W (range 235-425 W). OBLA occurred at a power output of 202 +/- 31 W (61% of W(max)) and VO(2) of 3.3 +/- 0.4 L/min (71% of VO(2peak)). The torque-crank velocity relationship was linear for all participants (r = 0.9 +/- 0.1). P (max) was 1,420 +/- 37 W (range 1,192-1,617 W), and omega(opt) was 125 +/- 6 rpm. These data are among the highest upper-body anaerobic and aerobic power values reported. The unique nature of these athletes, with their high fat-free mass and specific selection and training for standing arm cranking, likely accounts for the high values. The influence of crank velocity on peak power implies that power production during on-board 'grinding' may be optimised through the use of appropriate gear-ratios and the development of efficient gear change mechanisms.

  3. Caffeine Increases Work Done above Critical Power, but Not Anaerobic Work.

    PubMed

    Silveira, Rodrigo; Andrade-Souza, Victor Amorim; Arcoverde, Lucyana; Tomazini, Fabiano; Sansonio, André; Bishop, David John; Bertuzzi, Romulo; Lima-Silva, Adriano Eduardo

    2018-01-01

    The assumption that the curvature constant (W') of the power-duration relationship represents anaerobic work capacity is a controversial, unresolved question. We investigated if caffeine ingestion could increase total work done above critical power (CP), and if this would be accompanied by greater anaerobic energy expenditure and by an enhanced maintenance of maximal oxidative metabolic rate. Nine men (26.6 ± 5.3 yr, V˙O2max 40.6 ± 5.8 mL·kg·min) cycled until exhaustion at different exercise intensities on different days to determine the CP and W'. On separated days, participants cycled until exhaustion in the severe-intensity domain (136% ± 7% of CP) after ingesting either caffeine (5 mg·kg body mass) or a placebo. Time to exhaustion was 34% longer with caffeine compared with placebo, and this was accompanied by a greater work done above CP (23.7 ± 5.7 vs 17.5 ± 3.6 kJ; 130% ± 30% vs 95% ± 14% of W', P < 0.01). Caffeine increased the aerobic energy expenditure (296.4 ± 91.0 vs 210.2 ± 71.9 kJ, P < 0.01), but not anaerobic lactic, anaerobic alactic, and total anaerobic (lactic + alactic) energy expenditure. The end values of heart rate and ventilation were higher with caffeine, but the V˙O2 end was similar between conditions and was not different from V˙O2max. Caffeine did not change time to reach V˙O2max but increased time maintained at V˙O2max (199.3 ± 105.9 vs 111.9 ± 87.1 s, P < 0.05). Caffeine increased total work done above CP, but this was not associated with greater anaerobic work. Rather, this was associated with a higher tolerance to maintain exercise at maximal oxidative metabolic rate.

  4. TEST RESULTS FOR FUEL CELL OPERATION ON ANAEROBIC DIGESTER GAS

    EPA Science Inventory

    EPA, in conjunction with ONSI Corp., embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the proce...

  5. Utilization of the graded universal testing system to increase the efficiency for assessing aerobic and anaerobic capacity

    NASA Technical Reports Server (NTRS)

    Rodgers, Sandra L.

    1992-01-01

    The in-flight exercise test performed by cosmonauts as part of the Russian Exercise Countermeasure Program is limited to 5 minutes due to communication restrictions. During a recent graded exercise test on a U.S. Shuttle flight, the test was terminated early due to an upcoming loss of signal (LOS) with the ground. This exercise test was a traditional test where the subject's exercise capacity dictates the length of the test. For example, one crew member may take 15 minutes to complete the test, while another may take 18 minutes. The traditional exercise test limits the flight schedulers to large blocks of space flight time in order to provide medical and research personnel information on the fitness capacity (maximal oxygen uptake: VO2max) of crew members during flight. A graded exercise test that would take a finite amount of time and a set preparation and recovery time would ease this problem by allowing flight schedulers to plan exercise tests in advance of LOS. The Graded Universal Testing System (GUTS) was designed to meet this goal. Fitness testing of astronauts before and after flight provides pertinent data on many variables. The Detailed Supplemental Objective (DSO608) protocol (6) is one of the graded exercise tests (GXT) currently used in astronaut testing before and after flight. Test times for this protocol have lasted from 11 to 18 minutes. Anaerobic capacity is an important variable that is currently not being evaluated before and after flight. Recent reports (1,2,5) from the literature have suggested that the oxygen deficit at supramaximal exercise is a measure of anaerobic capacity. We postulated that the oxygen deficit at maximal exercise would be an indication of anaerobic capacity. If this postulate can be accepted, then the efficiency of acquiring data from a graded exercise test would increase at least twofold. To examine this hypothesis anaerobic capacity was measured using a modified treadmill test (3,4) designed to exhaust the anaerobic systems in approximately 45 to 75 seconds. Lactate concentration in the blood was analyzed after all tests, since lactate is the end-product of anaerobic energy production. Therefore, the peak lactate response is an additional indication of anaerobic capacity. A preliminary comparison of the GUTS and the DSO608 suggests that the GUTS protocol would increase the efficiency of VO2max testing of astronauts before and after flight. Results for anaerobic capacity have not been tabulated.

  6. Clinical evaluation of the Vitek ANI card for identification of anaerobic bacteria.

    PubMed Central

    Schreckenberger, P C; Celig, D M; Janda, W M

    1988-01-01

    An evaluation of the Vitek Anaerobe Identification (ANI) card was performed with 341 bacterial isolates, including 313 clinical isolates and 28 stock strains of anaerobic microorganisms. Identifications obtained with the ANI card were compared with those determined by conventional methods. The card identified 73.2% of 149 anaerobic gram-negative bacilli, 63.6% of 44 Clostridium spp., 65.8% of 38 anaerobic nonsporeforming gram-positive bacilli, and 69.1% of 110 anaerobic cocci, with no further testing required. When genus-level identifications were included, 83.9% of the anaerobic gram-negative bacilli, 70.5% of Clostridium spp., 73.7% of the anaerobic nonsporeforming gram-positive bacilli, and 73.6% of the anaerobic cocci were identified. Nineteen isolates (5.6%) produced identifications of good confidence but marginal separation or questionable biotype, in which the correct identification was listed with one or two other possible choices and extra tests were required and suggested. A total of 28 (8.2%) were not identified and 29 isolates (8.5%) were misidentified by the ANI card. Among the commonly isolated clinically significant anaerobes, the ANI card identified 100% of 55 Bacteroides fragilis and 100% of 8 Clostridium perfringens. Use of supplemental tests and expansion of the data base to include additional strains of organisms that are difficult to separate even with conventional methods may improve the accuracy of the ANI card as a method for identification of anaerobic bacteria in the clinical laboratory. PMID:3343321

  7. [Application of anaerobic bacteria detection in oral and maxillofacial infection].

    PubMed

    Bao, Zhen-ying; Lin, Qin; Meng, Yan-hong; He, Chun; Su, Jia-zeng; Peng, Xin

    2016-02-18

    To investigate the distribution and drug resistance of anaerobic bacteria in the patients with oral and maxillofacial infection. Aerobic and anaerobic bacteria cultures from 61 specimens of pus from the patients with oral and maxillofacial infection in the Department of Oral and Maxillofacial Surgery, Peking University School of Stomatology were identified. The culture type was evaluated by API 20A kit and drug resistance test was performed by Etest method. The clinical data and antibacterial agents for the treatment of the 61 cases were collected, and the final outcomes were recorded. The bacteria cultures were isolated from all the specimens, with aerobic bacteria only in 6 cases (9.8%), anaerobic bacteria only in 7 cases (11.5%), and both aerobic and anaerobic bacteria in 48 cases (78.7%). There were 55 infected cases (90.2%) with anaerobic bacteria, and 81 anaerobic bacteria stains were isolated. The highest bacteria isolation rate of Gram positive anaerobic bacteria could be found in Peptostreptococcus, Bifidobacterium and Pemphigus propionibacterium. No cefoxitin, amoxicillin/carat acid resistant strain was detected in the above three Gram positive anaerobic bacteria. The highest bacteria isolation rate of Gram negative anaerobic bacteria could be detected in Porphyromonas and Prevotella. No metronidazole, cefoxitin, amoxicillin/carat acid resistant strain was found in the two Gram negative anaerobic bacteria. In the study, 48 patients with oral and maxillofacial infection were treated according to the results of drug resistance testing, and the clinical cure rate was 81.3%. Mixed aerobic and anaerobic bacteria cultures are very common in most oral and maxillofacial infection patients. Anaerobic bacteria culture and drug resistance testing play an important role in clinical treatment.

  8. Total protein of whole saliva as a biomarker of anaerobic threshold.

    PubMed

    Bortolini, Miguel Junior Sordi; De Agostini, Guilherme Gularte; Reis, Ismair Teodoro; Lamounier, Romeu Paulo Martins Silva; Blumberg, Jeffrey B; Espindola, Foued Salmen

    2009-09-01

    Saliva provides a convenient and noninvasive matrix for assessing specific physiological parameters, including some biomarkers of exercise. We investigated whether the total protein concentration of whole saliva (TPWS) would reflect the anaerobic threshold during an incremental exercise test. After a warm-up period, 13 nonsmoking men performed a maximum incremental exercise on a cycle ergometer. Blood and stimulated saliva were collected during the test. The TPWS anaerobic threshold (PAT) was determined using the Dmax method. The PAT was correlated with the blood lactate anaerobic threshold (AT; r = .93, p < .05). No significant difference (p = .16) was observed between PAT and AT. Thus, TPWS provides a convenient and noninvasive matrix for determining the anaerobic threshold during incremental exercise tests.

  9. Muscle glycogen depletion and subsequent replenishment affect anaerobic capacity of horses.

    PubMed

    Lacombe, V A; Hinchcliff, K W; Geor, R J; Baskin, C R

    2001-10-01

    The purpose of this study was to determine the effect of muscle glycogen depletion and subsequent replenishment on anaerobic capacity of horses. In a blinded crossover study, seven fit horses performed glycogen-depleting exercise on two occasions. Horses were infused after glycogen-depleting exercise with either 6 g/kg body wt of glucose as a 13.5% solution in 0.9% NaCl (Glu) or with 0.9% NaCl (Sal) of equivalent volume. Subsequently, horses performed a high-speed exercise test (120% of maximal rate of oxygen consumption) to estimate maximum accumulated oxygen deficit. Replenishment of muscle glycogen was greater (P < 0.05) in Glu [from 24.7 +/- 7.2 (SE) to 116.5 +/- 7 mmol/kg wet wt before and after infusion, respectively] than in Sal (from 23.4 +/- 7.2 to 47.8 +/- 5.7 mmol/kg wet wt before and after infusion, respectively). Run time to fatigue during the high-speed exercise test (97.3 +/- 8.2 and 70.8 +/- 8.3 s, P < 0.05), maximal accumulated oxygen deficit (105.7 +/- 9.3 and 82.4 +/- 10.3 ml O(2) equivalent/kg, P < 0.05), and blood lactate concentration at the end of the high-speed exercise test (11.1 +/- 1.4 and 9.2 +/- 3.7 mmol/l, P < 0.05) were greater for Glu than for Sal, respectively. We concluded that decreased availability of skeletal muscle glycogen stores diminishes anaerobic power generation and capacity for high-intensity exercise in horses.

  10. Relationship between Physiological Off-Ice Testing, On-Ice Skating, and Game Performance in Division I Women's Ice Hockey Players.

    PubMed

    Boland, Michelle; Miele, Emily M; Delude, Katie

    2017-10-07

    The purpose was to identify off-ice testing variables that correlate to skating and game performance in Division I collegiate women ice hockey players. Twenty female, forward and defensive players (19.95 ± 1.35 yr) were assessed for weight, height, percent fat mass (%FAT), bone mineral density, predicted one repetition maximum (RM) absolute and relative (REL%) bench press (BP) and hex bar deadlift (HDL), lower body explosive power, anaerobic power, countermovement vertical jump (CMJ), maximum inspiratory pressure (MIP), and on-ice repeated skate sprint (RSS) performance. The on-ice RSS test included 6 timed 85.6 m sprints with participants wearing full hockey equipment; fastest time (FT), average time (AT) and fatigue index (FI) for the first length skate (FLS; 10 m) and total length skate (TLS; 85.6 m) were used for analysis. Game performance was evaluated with game statistics: goals, assists, points, plus-minus, and shots on goal (SOG). Correlation coefficients were used to determine relationships. Percent fat mass was positively correlated (p < 0.05) with FLS-FI and TLS-AT; TLS-FT was negatively correlated with REL%HDL; BP-RM was negatively correlated with FLS-FT and FLS-AT; MIP positively correlated with assists, points, and SOG; FLS-AT negatively correlated with assists. Game performance in women ice hockey players may be enhanced by greater MIP, repeat acceleration ability, and mode-specific training. Faster skating times were associated with lower %FAT. Skating performance in women ice hockey players may be enhanced by improving body composition, anaerobic power, and both lower and upper body strength in off-ice training.

  11. Integrated Anaerobic-Aerobic Biodegradation of Multiple Contaminants Including Chlorinated Ethylenes, Benzene, Toluene, and Dichloromethane.

    PubMed

    Yoshikawa, Miho; Zhang, Ming; Toyota, Koki

    2017-01-01

    Complete bioremediation of soils containing multiple volatile organic compounds (VOCs) remains a challenge. To explore the possibility of complete bioremediation through integrated anaerobic-aerobic biodegradation, laboratory feasibility tests followed by alternate anaerobic-aerobic and aerobic-anaerobic biodegradation tests were performed. Chlorinated ethylenes, including tetrachloroethylene (PCE), trichloroethylene (TCE), cis -dichloroethylene ( cis -DCE), and vinyl chloride (VC), and dichloromethane (DCM) were used for anaerobic biodegradation, whereas benzene, toluene, and DCM were used for aerobic biodegradation tests. Microbial communities involved in the biodegradation tests were analyzed to characterize the major bacteria that may contribute to biodegradation. The results demonstrated that integrated anaerobic-aerobic biodegradation was capable of completely degrading the seven VOCs with initial concentration of each VOC less than 30 mg/L. Benzene and toluene were degraded within 8 days, and DCM was degraded within 20 to 27 days under aerobic conditions when initial oxygen concentrations in the headspaces of test bottles were set to 5.3% and 21.0%. Dehalococcoides sp., generally considered sensitive to oxygen, survived aerobic conditions for 28 days and was activated during the subsequent anaerobic biodegradation. However, degradation of cis -DCE was suppressed after oxygen exposure for more than 201 days, suggesting the loss of viability of Dehalococcoides sp., as they are the only known anaerobic bacteria that can completely biodegrade chlorinated ethylenes to ethylene. Anaerobic degradation of DCM following previous aerobic degradation was complete, and yet-unknown microbes may be involved in the process. The findings may provide a scientific and practical basis for the complete bioremediation of multiple contaminants in situ and a subject for further exploration.

  12. Modification of the Minitek Miniaturized Differentiation System for characterization of anaerobic bacteria.

    PubMed Central

    Stargel, D; Thompson, F S; Phillips, S E; Lombard, G L; Dowell, V R

    1976-01-01

    The Minitek Miniaturized System (BBL) was modified for characterization of anaerobic bacteria. The modified system and the conventional Center for Disease Control method were used to test a variety of anaerobic bacteria, and results were compared. Tests performed by both techniques were indole and H2S production, esculin hydrolysis, nitrate reduction, and fermentation of glucose, mannitol, lactose, sucrose, maltose, salicin, glycerol, xylose, arabinose, mannose, rhamnose, and trehalose. The manufacturer's recommended procedure for the Minitek system was modified by using a new suspension medium (Lombard-Dowell broth) and an inoculum equivalent to the density of a McFarland no. 5 nephelometer standard. The Minitek results, recorded after 48 h, agreed satisfactorily with the conventional test results, usually recorded after 5 to 7 days of incubation. In the examination of 80 strains representing 22 different species or subspecies of anaerobic bacteria, with 16 biochemical tests performed in triplicate, 93.8% of the Minitek test results agreed with those of the corresponding conventional tests. Only tests for indole, H2S, and nitrate reduction gave less than 90% agreement. It was concluded that the modified Minitek system is a suitable substitute for the more expensive and time-consuming conventional procedure for determining carbohydrate fermentation and esculin hydrolysis by anaerobes. This system, when used in conjunction with other tests, can effectively aid in the definitive identification of commonly isolated anaerobes. Images PMID:773959

  13. Validity of the Wingate anaerobic test for the evaluation of elite runners.

    PubMed

    Legaz-Arrese, Alejandro; Munguía-Izquierdo, Diego; Carranza-García, Luis E; Torres-Dávila, Celeste G

    2011-03-01

    This study aimed to determine performance differences, based on the Wingate anaerobic test (WAnT), between homogeneous groups of elite male and female runners competing at distances ranging from 100 m to the marathon. We also attempted to establish a link between running ability and performance as measured by the WAnT. In total, 116 world-class runners (86 men and 30 woman) volunteered to participate in our study. Subjects were tested for peak power (PP, 5-second output) and mean power (MP, 30-second output) using WAnT procedures. Runners were classified into groups according to their best performances times. For male runners, PP and MP outputs decreased with increasing distance (p < 0.001). This trend was also true for female runners (p < 0.005). However, for both sexes, there were no significant differences in the PP values among 100-, 400-, and 800-m runners, and there were also no differences in the MP values for subjects that ran distances of 100 m compared with the values for subjects that ran distances of 400 and 800 m. In addition, no significant differences were observed in the PP and MP values between subjects that ran distances of 800, 1,500, and 3,000 m. Performance in the WAnT was not significantly associated with running performance in any distance event. The results of this study indicate that the WAnT is not a useful tool for the evaluation of elite runners.

  14. Potential of hydrolysis of particulate COD in extended anaerobic conditions to enhance biological phosphorous removal.

    PubMed

    Jabari, P; Yuan, Q; Oleszkiewicz, J A

    2016-11-01

    The effect of anaerobic hydrolysis of particulate COD (pCOD) on biological phosphorous removal in extended anaerobic condition was investigated through (i) sequencing batch reactors (SBR)s with anaerobic hydraulic retention time (HRT) of 0.8, 2, and 4 h; (ii) batch tests using biomass from a full scale biological nutrient removal (BNR) plant; and (iii) activated sludge modeling (BioWin 4.1 simulation). The results from long-term SBRs operation showed that phosphorus removal was correlated to the ratio of filtered COD (FCOD) to total phosphorus (TP) in the influent. Under conditions with low FCOD/TP ratio (average of 20) in the influent, extending anaerobic HRT to 4 h in the presence of pCOD did not significantly improve overall phosphorous removal. During the period with high FCOD/TP ratio (average of 37) in the influent, all SBRs removed phosphorous completely, and the long anaerobic HRT did not have negative effect on overall phosphorous removal. The batch tests also showed that pCOD at different concentration during 4 h test did not affect the rate of anaerobic phosphorus release. The rate of anaerobic hydrolysis of pCOD was significantly low and extending the anaerobic HRT was ineffective. The simulation (BioWin 4.1) of SBRs with low influent FCOD/TP ratio showed that the default kinetics of anaerobic hydrolysis in ASM2d overestimated phosphorous removal in the SBRs (high anaerobic hydrolysis of pCOD). The default anaerobic hydrolysis rate in BioWin 4.1 (ten times lower) could produce similar phosphorous removal to that in the experiment. Results showed that the current kinetics of anaerobic hydrolysis in ASM2d could lead to considerable error in predicting phosphorus removal in processes with extended anaerobic HRT. Biotechnol. Bioeng. 2016;113: 2377-2385. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Identification and Antimicrobial Susceptibility Testing of Anaerobic Bacteria: Rubik’s Cube of Clinical Microbiology?

    PubMed Central

    Gajdács, Márió; Spengler, Gabriella; Urbán, Edit

    2017-01-01

    Anaerobic bacteria have pivotal roles in the microbiota of humans and they are significant infectious agents involved in many pathological processes, both in immunocompetent and immunocompromised individuals. Their isolation, cultivation and correct identification differs significantly from the workup of aerobic species, although the use of new technologies (e.g., matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, whole genome sequencing) changed anaerobic diagnostics dramatically. In the past, antimicrobial susceptibility of these microorganisms showed predictable patterns and empirical therapy could be safely administered but recently a steady and clear increase in the resistance for several important drugs (β-lactams, clindamycin) has been observed worldwide. For this reason, antimicrobial susceptibility testing of anaerobic isolates for surveillance purposes or otherwise is of paramount importance but the availability of these testing methods is usually limited. In this present review, our aim was to give an overview of the methods currently available for the identification (using phenotypic characteristics, biochemical testing, gas-liquid chromatography, MALDI-TOF MS and WGS) and antimicrobial susceptibility testing (agar dilution, broth microdilution, disk diffusion, gradient tests, automated systems, phenotypic and molecular resistance detection techniques) of anaerobes, when should these methods be used and what are the recent developments in resistance patterns of anaerobic bacteria. PMID:29112122

  16. Identification and Antimicrobial Susceptibility Testing of Anaerobic Bacteria: Rubik's Cube of Clinical Microbiology?

    PubMed

    Gajdács, Márió; Spengler, Gabriella; Urbán, Edit

    2017-11-07

    Anaerobic bacteria have pivotal roles in the microbiota of humans and they are significant infectious agents involved in many pathological processes, both in immunocompetent and immunocompromised individuals. Their isolation, cultivation and correct identification differs significantly from the workup of aerobic species, although the use of new technologies (e.g., matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, whole genome sequencing) changed anaerobic diagnostics dramatically. In the past, antimicrobial susceptibility of these microorganisms showed predictable patterns and empirical therapy could be safely administered but recently a steady and clear increase in the resistance for several important drugs (β-lactams, clindamycin) has been observed worldwide. For this reason, antimicrobial susceptibility testing of anaerobic isolates for surveillance purposes or otherwise is of paramount importance but the availability of these testing methods is usually limited. In this present review, our aim was to give an overview of the methods currently available for the identification (using phenotypic characteristics, biochemical testing, gas-liquid chromatography, MALDI-TOF MS and WGS) and antimicrobial susceptibility testing (agar dilution, broth microdilution, disk diffusion, gradient tests, automated systems, phenotypic and molecular resistance detection techniques) of anaerobes, when should these methods be used and what are the recent developments in resistance patterns of anaerobic bacteria.

  17. The Kansas Squat Test Modality Comparison: Free Weights vs. Smith Machine.

    PubMed

    Luebbers, Paul E; Fry, Andrew C

    2016-08-01

    Luebbers, PE and Fry, AC. The Kansas squat test modality comparison: free weights vs. smith machine. J Strength Cond Res 30(8): 2186-2193, 2016-Standardized methods of testing power are instrumental in planning and implementing training regimens for many athletes, and also in tracking training adaptations. Previous work has demonstrated that the Kansas squat test (KST) is a valid test for measuring indices of mean and peak power when compared with the Wingate anaerobic cycle test. Although the KST was designed for use with a Smith machine (SM), many power athletes use free weights for training. The purpose of this study was to determine the feasibility of using free weights (FW) for the KST by comparing it with the SM modality. Twenty-three track and field athletes participated (mean ± SD; weight, 69.7 ± 10.6 kg; age, 20.1 ± 1.1 years) in this study. Each completed familiarization sessions with the FW and SM modalities before data collection. A 1-repetition maximum squat was also determined for both the FW and SM. Correlation coefficients indicated significant relationships between the FW KST and SM KST on measures of peak test power (r = 0.955; p < 0.01) and mean test power (r = 0.959; p < 0.01) but not for relative fatigue (r = -0.198; p > 0.05) or posttest lactate (r = 0.109; p > 0.05). Paired samples t-tests indicated that the FW KST resulted in significantly higher measures of peak power and mean power (p ≤ 0.01), although no differences were observed for relative fatigue or lactate (p > 0.05). These data indicate that the FW KST is a valid and feasible alternative to the SM KST in measuring peak and mean power.

  18. State Of The Science On Cogeneration Of Heat And Power From Anaerobic Digestion Of Municipal Biosolids

    EPA Science Inventory

    This presentation will report on work underway to inventory facilities currently utilizing biogas from anaerobic digestion and speak with practitioners to learn: techniques for preparing residuals for digestion, methods to use for cleaning biogas (e.g., of siloxane), and how gas...

  19. No Improvement in Sprint Performance With a Neuromuscular Fitted Dental Splint.

    PubMed

    Fischer, Henrike; Weber, Daniel; Beneke, Ralph

    2017-03-01

    Mouth guards protect against orofacial and dental injuries in sports. However, special fitted dental splints have been claimed to improve strength and speed and, therefore, to enhance athletic performance. To test the effects of a neuromuscular fitted dental splint in comparison with a habitual verticalizing splint and a no-splint condition on cycling sprint performance in the Wingate Anaerobic Test (WAnT). Twenty-three men (26.0 ± 2.0 y, 1.82 ± 0.06 m, 79.4 ± 7.7 kg) performed 3 WAnTs, 1 with the neuromuscular fitted splint, 1 with a habitual verticalized dental splint of the same height and material, and 1 under control conditions without any mouth guard, in randomized order separated by 1 wk. No differences between any splint conditions were found in any aspect of WAnT performance (time to peak power, peak power, minimum power, power drop, and average power). Moderate to nearly perfect correlations between all splint conditions in all WAnT outcomes with coefficients of variation between 1.3% and 6.6% were found. Irrespective of habitual verticalization or myocentric positioning, dental splints have no effects on any aspect of WAnT performance. Results are comparable to those of test-retest experiments.

  20. The relationship of aerobic capacity, anaerobic peak power and experience to performance in CrossFit exercise.

    PubMed

    Bellar, D; Hatchett, A; Judge, L W; Breaux, M E; Marcus, L

    2015-11-01

    CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in duration, and the second was based on the total time to complete the prescribed exercise. The participants were 32 healthy adult males, who were either naïve to CrossFit exercise or had competed in CrossFit competitions. Linear regression was undertaken to predict performance on the first workout (time) with age, group (naïve or CrossFit athlete), VO2max and anaerobic power, which were all significant predictors (p < 0.05) in the model. The second workout (repetitions), when examined similarly using regression, only resulted in CrossFit experience as a significant predictor (p < 0.05). The results of the study suggest that a history of participation in CrossFit competition is a key component of performance in CrossFit workouts which are representative of those performed in CrossFit, and that, in at least one these workouts, aerobic capacity and anaerobic power are associated with success.

  1. The relationship of aerobic capacity, anaerobic peak power and experience to performance in CrossFit exercise

    PubMed Central

    Hatchett, A; Judge, LW; Breaux, ME; Marcus, L

    2015-01-01

    CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in duration, and the second was based on the total time to complete the prescribed exercise. The participants were 32 healthy adult males, who were either naïve to CrossFit exercise or had competed in CrossFit competitions. Linear regression was undertaken to predict performance on the first workout (time) with age, group (naïve or CrossFit athlete), VO2max and anaerobic power, which were all significant predictors (p < 0.05) in the model. The second workout (repetitions), when examined similarly using regression, only resulted in CrossFit experience as a significant predictor (p < 0.05). The results of the study suggest that a history of participation in CrossFit competition is a key component of performance in CrossFit workouts which are representative of those performed in CrossFit, and that, in at least one these workouts, aerobic capacity and anaerobic power are associated with success. PMID:26681834

  2. Relationship of physical fitness test results and hockey playing potential in elite-level ice hockey players.

    PubMed

    Burr, Jaime F; Jamnik, Roni K; Baker, Joseph; Macpherson, Alison; Gledhill, Norman; McGuire, E J

    2008-09-01

    The primary purpose of this study was to determine the fitness variables with the highest capability for predicting hockey playing potential at the elite level as determined by entry draft selection order. We also examined the differences associated with the predictive abilities of the test components among playing positions. The secondary purpose of this study was to update the physiological profile of contemporary hockey players including positional differences. Fitness test results conducted by our laboratory at the National Hockey League Entry Draft combine were compared with draft selection order on a total of 853 players. Regression models revealed peak anaerobic power output to be important for higher draft round selection in all positions; however, the degree of importance of this measurement varied with playing position. The body index, which is a composite score of height, lean mass, and muscular development, was similarly important in all models, with differing influence by position. Removal of the goalies' data increased predictive capacity, suggesting that talent identification using physical fitness testing of this sort may be more appropriate for skating players. Standing long jump was identified as a significant predictor variable for forwards and defense and could be a useful surrogate for assessing overall hockey potential. Significant differences exist between the physiological profiles of current players based on playing position. There are also positional differences in the relative importance of anthropometric and fitness measures of off-ice hockey tests in relation to draft order. Physical fitness measures and anthropometric data are valuable in helping predict hockey playing potential. Emphasis on anthropometry should be used when comparing elite-level forwards, whereas peak anaerobic power and fatigue rate are more useful for differentiating between defense.

  3. Physiological characteristics of an aging Olympic athlete.

    PubMed

    Nybo, Lars; Schmidt, Jakob F; Fritzdorf, Stephen; Nordsborg, Nikolai B

    2014-11-01

    To investigate the physiological basis of continued world-class performance of a world-class rower who won medals (three gold and two bronze) at five consecutive Olympic Games. From the age of 19 to 40 yr, maximal oxygen uptake (VO2 max), peak HR, blood lactate, and rowing ergometer performance were assessed annually. During the first years of his elite career (from age 19 to 24), VO2 max increased from 5.5 to approximately 5.9 L · min(-1) (78 mL · min(-1) · kg(-1)) and his average power during 6-min maximal rowing increased from 420 to approximately 460 W. Although his HRmax declined by approximately 20 bpm during the 20-yr period, maximal aerobic power, evaluated both as VO2 max and 6-min test performance, was maintained until the age of 40. Furthermore, peak lactate levels remained unchanged and average power outputs during 10-s, 60-s, and 60-min ergometer tests were all maintained at approximately 800 W, approximately 700 W, and approximately 350 W, respectively, indicating that he was able to preserve both aerobic and anaerobic exercise performances. Echocardiographic analyses revealed a left ventricular mass of 198 g and left ventricular end-diastolic diameter of 5.8 cm. This longitudinal case indicates that until the age of 40 yr, a steady increase in the oxygen pulse may have compensated for the significant decline in the maximal heart frequency. Furthermore, the maintenance of aerobic and anaerobic exercise capacities allowed this Olympic athlete to compete at the highest level for almost two decades.

  4. The effect of extrinsic motivation on cycle time trial performance.

    PubMed

    Hulleman, Michiel; De Koning, Jos J; Hettinga, Florentina J; Foster, Carl

    2007-04-01

    Athletes occasionally follow pacing patterns that seem unreasonably aggressive compared with those of prerace performances, potentially because of the motivation provided by competition. This study evaluated the effect of extrinsic motivation on cyclists' time trial performance. Well-trained recreational cyclists (N=7) completed four 1500-m laboratory time trials including a practice trial, two self-paced trials, and a trial where a monetary reward was offered. Time, total power output, power output attributable to aerobic and anaerobic metabolic sources, VO2, and HR were measured. The time required for the second, third, and last (extrinsically motivated) time trials was 133.1 +/- 2.1, 134.1 +/- 3.4, and 133.6 +/- 3.0 s, respectively, and was not different (P>0.05). There were no differences for total (396 +/- 19, 397 +/- 23, and 401 +/- 17 W), aerobic (253 +/- 12, 254 +/- 10, and 246 +/- 13 W), and anaerobic (143 +/- 14, 143 +/- 21, and 155 +/- 11 W) power output. The highest VO2 was not different over consecutive time trials (3.76 +/- 0.19, 3.73 +/- 0.16, and 3.71 +/- 0.22 L x min(-1)). When ranked by performance, without reference to the extrinsic motivation (131.9 +/- 2.4, 133.4 +/- 2.4, and 135.4 +/- 2.5 s), there was a significant difference for the first 100 m and from 100 to 300 m in power output, with a larger total power (560 +/- 102, 491 +/- 82, and 493 +/- 93; and 571 +/- 94, 513 +/- 41, and 484 +/- 88 W) and power attributable to anaerobic sources (446 +/- 100, 384 +/- 80, and 324 +/- 43; and 381 +/- 87, 383 +/- 90, and 289 +/- 91 W) for the fastest trial. Extrinsic motivation did not change the time trial performance, suggesting that 1500-m performance is extremely stable and not readily changeable with simple external motivation. The results suggest that spontaneous improvement in performance for time trials of this duration is attributable to greater early power output, which is primarily attributable to anaerobic metabolic sources.

  5. Frequency of resistance in obligate anaerobic bacteria isolated from dogs, cats, and horses to antimicrobial agents.

    PubMed

    Lawhon, S D; Taylor, A; Fajt, V R

    2013-11-01

    Clinical specimens from dogs, cats, and horses were examined for the presence of obligate anaerobic bacteria. Of 4,018 specimens cultured, 368 yielded 606 isolates of obligate anaerobic bacteria (248 from dogs, 50 from cats, and 308 from horses). There were 100 specimens from 94 animals from which only anaerobes were isolated (25 dogs, 8 cats, and 61 horses). The most common sites tested were abdominal fluid (dogs and cats) and intestinal contents (horses). The most common microorganism isolated from dogs, cats, and horses was Clostridium perfringens (75, 13, and101 isolates, respectively). The MICs of amoxicillin with clavulanate, ampicillin, chloramphenicol, metronidazole, and penicillin were determined using a gradient endpoint method for anaerobes. Isolates collected at necropsy were not tested for antimicrobial susceptibility unless so requested by the clinician. There were 1/145 isolates tested that were resistant to amoxicillin-clavulanate (resistance breakpoint ≥ 16/8 μg/ml), 7/77 isolates tested were resistant to ampicillin (resistance breakpoint ≥ 2 μg/ml), 4/242 isolates tested were resistant to chloramphenicol (resistance breakpoint ≥ 32 μg/ml), 12/158 isolates tested were resistant to clindamycin (resistance breakpoint ≥ 8 μg/ml), 10/247 isolates tested were resistant to metronidazole (resistance breakpoint ≥ 32 μg/ml), and 54/243 isolates tested were resistant to penicillin (resistance breakpoint ≥ 2 μg/ml). These data suggest that anaerobes are generally susceptible to antimicrobial drugs in vitro.

  6. 40 CFR 98.466 - Data reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... from Table TT-1 to this subpart, a measured value using a 60-day anaerobic biodegradation test as... § 98.464(b)(4)(ii). If DOCX was determined by a 60-day anaerobic biodegradation test, specify the test...

  7. A miniature microbial fuel cell operating with an aerobic anode chamber

    NASA Astrophysics Data System (ADS)

    Ringeisen, Bradley R.; Ray, Ricky; Little, Brenda

    A miniature microbial fuel cell (mini-MFC) is described that utilizes an aerobic culture of Shewanella oneidensis DSP10 as the active electrochemical species in the anode chamber. We find that the maximum aerobic mini-MFC power without the addition of exogenous mediators was 0.40 mW, a 33% decrease when compared with an anaerobic DSP10 culture (0.6 mW) operating in the mini-MFC. This decrease is most likely due to the presence of dissolved oxygen in the anode chamber that scavenges electrons to form water, thereby reducing the number of electrons donated to the anode. Aerobic power and current density at maximum power using the true surface area of the anode (611 cm 2) were calculated to be 6.5 mW m -2 and 13 mA m -2. The power density rises to 2.0 W m -2 and 330 W m -3 when calculated using the cross-sectional area and volume of the device (2 cm 2, 1.2 cm 3). The Coulombic efficiency was also reduced from 11 to 5% when using the aerobic versus anaerobic culture. Similar results were found when the external mediator anthraquinone-2,6-disulfonate (AQDS) was added to the aerobic culture, resulting in a maximum power of 0.54 mW, a 37% drop in power when compared to the anaerobic mediated system.

  8. Antimicrobial susceptibility of clinical isolates of anaerobic bacteria in Ontario, 2010-2011.

    PubMed

    Marchand-Austin, Alex; Rawte, Prasad; Toye, Baldwin; Jamieson, Frances B; Farrell, David J; Patel, Samir N

    2014-08-01

    The local epidemiology of antimicrobial susceptibility patterns in anaerobic bacteria is important in guiding the empiric treatment of infections. However, susceptibility data are very limited on anaerobic organisms, particularly among non-Bacteroides organisms. To determine susceptibility profiles of clinically-significant anaerobic bacteria in Ontario Canada, anaerobic isolates from sterile sites submitted to Public Health Ontario Laboratory (PHOL) for identification and susceptibility testing were included in this study. Using the E-test method, isolates were tested for various antimicrobials including, penicillin, cefoxitin, clindamycin, meropenem, piperacillin-tazobactam and metronidazole. The MIC results were interpreted based on guidelines published by Clinical and Laboratory Standards Institute. Of 2527 anaerobic isolates submitted to PHOL, 1412 were either from sterile sites or bronchial lavage, and underwent susceptibility testing. Among Bacteroides fragilis, 98.2%, 24.7%, 1.6%, and 1.2% were resistant to penicillin, clindamycin, piperacillin-tazobactam, and metronidazole, respectively. Clostridium perfringens was universally susceptible to penicillin, piperacillin-tazobactam, and meropenem, whereas 14.2% of other Clostridium spp. were resistant to penicillin. Among Gram-positive anaerobes, Actinomyces spp., Parvimonas micra and Propionibacterium spp. were universally susceptible to β-lactams. Eggerthella spp., Collinsella spp., and Eubacterium spp. showed variable resistance to penicillin. Among Gram-negative anaerobes, Fusobacterium spp., Prevotella spp., and Veillonella spp. showed high resistance to penicillin but were universally susceptible to meropenem and piperacillin-tazobactam. The detection of metronidazole resistant B. fragilis is concerning as occurrence of these isolates is extremely rare. These data highlight the importance of ongoing surveillance to provide clinically relevant information to clinicians for empiric management of infections caused by anaerobic organisms. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  9. Changes in the antibiotic susceptibility of anaerobic bacteria from 2007-2009 to 2010-2012 based on the CLSI methodology.

    PubMed

    Hastey, Christine J; Boyd, Halsey; Schuetz, Audrey N; Anderson, Karen; Citron, Diane M; Dzink-Fox, Jody; Hackel, Meredith; Hecht, David W; Jacobus, Nilda V; Jenkins, Stephen G; Karlsson, Maria; Knapp, Cynthia C; Koeth, Laura M; Wexler, Hannah; Roe-Carpenter, Darcie E

    2016-12-01

    Antimicrobial susceptibility testing of anaerobic isolates was conducted at four independent sites from 2010 to 2012 and compared to results from three sites during the period of 2007-2009. This data comparison shows significant changes in antimicrobial resistance in some anaerobic groups. Therefore, we continue to recommend institutions regularly perform susceptibility testing when anaerobes are cultured from pertinent sites. Annual generation of an institutional-specific antibiogram is recommended for tracking of resistance trends over time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Effects of four weeks of high-intensity interval training and creatine supplementation on critical power and anaerobic working capacity in college-aged men.

    PubMed

    Kendall, Kristina L; Smith, Abbie E; Graef, Jennifer L; Fukuda, David H; Moon, Jordan R; Beck, Travis W; Cramer, Joel T; Stout, Jeffrey R

    2009-09-01

    The critical power test provides 2 measures, critical power (CP) and anaerobic working capacity (AWC). In theory, the CP measurement represents the maximal power output that can be maintained without fatigue, and AWC is an estimate of work capacity associated with muscle energy reserves. High-intensity interval training (HIIT) has been shown to be an effective training method for improving endurance performance, including VO2PEAK. In addition, creatine (Cr) supplementation has been reported to improve AWC without training; however, it has shown no effect on CP. The purpose of this study was to examine the effects of 4 weeks of HIIT with Cr supplementation on CP and AWC. Forty-two recreationally active men volunteered to participate in this study. Participants were randomly assigned to 1 of 3 groups: Cr (n = 16), 10 g Cr + 10 g dextrose; placebo (PL, n = 16), 20 g dextrose; control (CON, n = 10), no treatment. Before and after supplementation, each participant performed a maximal oxygen consumption test VO2PEAK on a cycle ergometer to establish peak power output (PPO). Participants then completed a CP test involving 3 exercise bouts with the workloads set as a percentage of their PPO to determine CP and AWC. After a 2-week familiarization period of training and supplementing, PPO, CP, and AWC were remeasured before an additional 4 weeks of HIIT and supplementation were completed. Training consisted of 5 sets of 2-minute exercise bouts with 1 minute rest in between performed on the cycle ergometer, with intensities based on PPO. A significant improvement in CP was observed in the Cr group (6.72% +/- 2.54%), whereas PL showed no significant change (3.87% +/- 2.30%), and CON significantly decreased (6.27% +/- 2.38%). Furthermore, no changes in AWC were observed in any of the groups after treatment. The current findings suggest that Cr supplementation may enhance the effects of intense interval endurance training on endurance performance changes.

  11. The effects of salmeterol on power output in nonasthmatic athletes.

    PubMed

    McDowell, S L; Fleck, S J; Storms, W W

    1997-04-01

    Salmeterol xinafoate is a new aerosol inhalant that is used in the treatment of asthma. It is currently banned by the International Olympic Committee because of the concern that it may lend an unfair competitive advantage to the user. The purpose of this study was to determine whether salmeterol improves short-term anaerobic performance in elite nonasthmatic track cyclists. Eleven elite track cyclists volunteered to perform a 30-second all-out cycle ergometer test 3 hours after receiving either 42 micrograms of salmeterol xinafoate or placebo applied in a double-blind crossover procedure. During the ergometer test, peak power output, total work, time to peak power, and percent fatigue (decline in power output) were measured. Pulmonary measurements were also taken before and at various time points after inhalation and the ergometer test. A methacholine challenge was administered to each subject before participation in the study to ensure that none of the subjects had any reactive airway diseases. There were no significant differences (p > 0.05) between the placebo and salmeterol trials for peak power output, total work performed during the 30-second test, percent fatigue, and time to peak power. No differences between trials were observed for the pulmonary function test variables at any of the time points. Blood lactate concentrations before and after administration of drug or placebo were also not significantly different between trials. Additionally, salmeterol did not affect the maximal heart rate achieved during the test as compared with the placebo. Short-term salmeterol use within the prescribed dosage was not shown to increase short-term power output in nonasthmatic cyclists.

  12. Plasticity of muscle function in a thermoregulating ectotherm (Crocodylus porosus): biomechanics and metabolism.

    PubMed

    Seebacher, Frank; James, Rob S

    2008-03-01

    Thermoregulation and thermal sensitivity of performance are thought to have coevolved so that performance is optimized within the selected body temperature range. However, locomotor performance in thermoregulating crocodiles (Crocodylus porosus) is plastic and maxima shift to different selected body temperatures in different thermal environments. Here we test the hypothesis that muscle metabolic and biomechanical parameters are optimized at the body temperatures selected in different thermal environments. Hence, we related indices of anaerobic (lactate dehydrogenase) and aerobic (cytochrome c oxidase) metabolic capacities and myofibrillar ATPase activity to the biomechanics of isometric and work loop caudofemoralis muscle function. Maximal isometric stress (force per muscle cross-sectional area) did not change with thermal acclimation, but muscle work loop power output increased with cold acclimation as a result of shorter activation and relaxation times. The thermal sensitivity of myofibrillar ATPase activity decreased with cold acclimation in caudofemoralis muscle. Neither aerobic nor anaerobic metabolic capacities were directly linked to changes in muscle performance during thermal acclimation, although there was a negative relationship between anaerobic capacity and isometric twitch stress in cold-acclimated animals. We conclude that by combining thermoregulation with plasticity in biomechanical function, crocodiles maximize performance in environments with highly variable thermal properties.

  13. The effect of two different interval-training programmes on physiological and performance indices.

    PubMed

    Sindiani, Mahmood; Eliakim, Alon; Segev, Daria; Meckel, Yoav

    2017-08-01

    The aim of the present study was to compare the effect of an increasing-distance, interval-training programme and a decreasing-distance, interval-training programme, matched for total distance, on aerobic and anaerobic physiological indices. Forty physical education students were randomly assigned to either the increasing- or decreasing-distance, interval-training group (ITG and DTG), and completed two similar relevant sets of tests before and after six weeks of training. One training programme consisted of increasing-distance interval-training (100-200-300-400-500 m) and the other decreasing-distance interval training (500-400-300-200-100 m). While both training programmes led to a significant improvement in VO 2 max (ES = 0.83-1.25), the improvement in the DTG was significantly greater than in the ITG (14.5 ± 3.6 vs. 7.8 ± 3.2%, p < .05). In addition, while both training programmes led to a significant improvement in all anaerobic indices (ES = 0.83-1.63), the improvements in peak power (15.7 ± 7.8 vs. 8.9 ± 4.7), mean power (10.6 ± 5.4 vs. 6.8 ± 4.4), and fatigue index (18.2 ± 10.9 vs. 7.0 ± 14.2) were significantly greater in the DTG compared to the ITG (p < .05). The main finding of the present study was that beyond the significant positive effects of both training programmes on aerobic and anaerobic fitness, the DTG showed significant superiority over the ITG in improving aerobic and anaerobic performance capabilities. Coaches and athletes should therefore be aware that, in spite of identical total work, an interval-training programme might induce different physiological impacts if the order of intervals is not identical.

  14. Do physiological measures predict selected CrossFit® benchmark performance?

    PubMed Central

    Butcher, Scotty J; Neyedly, Tyler J; Horvey, Karla J; Benko, Chad R

    2015-01-01

    Purpose CrossFit® is a new but extremely popular method of exercise training and competition that involves constantly varied functional movements performed at high intensity. Despite the popularity of this training method, the physiological determinants of CrossFit performance have not yet been reported. The purpose of this study was to determine whether physiological and/or muscle strength measures could predict performance on three common CrossFit “Workouts of the Day” (WODs). Materials and methods Fourteen CrossFit Open or Regional athletes completed, on separate days, the WODs “Grace” (30 clean and jerks for time), “Fran” (three rounds of thrusters and pull-ups for 21, 15, and nine repetitions), and “Cindy” (20 minutes of rounds of five pull-ups, ten push-ups, and 15 bodyweight squats), as well as the “CrossFit Total” (1 repetition max [1RM] back squat, overhead press, and deadlift), maximal oxygen consumption (VO2max), and Wingate anaerobic power/capacity testing. Results Performance of Grace and Fran was related to whole-body strength (CrossFit Total) (r=−0.88 and −0.65, respectively) and anaerobic threshold (r=−0.61 and −0.53, respectively); however, whole-body strength was the only variable to survive the prediction regression for both of these WODs (R2=0.77 and 0.42, respectively). There were no significant associations or predictors for Cindy. Conclusion CrossFit benchmark WOD performance cannot be predicted by VO2max, Wingate power/capacity, or either respiratory compensation or anaerobic thresholds. Of the data measured, only whole-body strength can partially explain performance on Grace and Fran, although anaerobic threshold also exhibited association with performance. Along with their typical training, CrossFit athletes should likely ensure an adequate level of strength and aerobic endurance to optimize performance on at least some benchmark WODs. PMID:26261428

  15. Enhanced decolorization of azo dye in a small pilot-scale anaerobic baffled reactor coupled with biocatalyzed electrolysis system (ABR-BES): a design suitable for scaling-up.

    PubMed

    Cui, Dan; Guo, Yu-Qi; Lee, Hyung-Sool; Wu, Wei-Min; Liang, Bin; Wang, Ai-Jie; Cheng, Hao-Yi

    2014-07-01

    A four-compartment anaerobic baffled reactor (ABR) incorporated with membrane-less biocatalyzed electrolysis system (BES) was tested for the treatment of azo dye (alizarin yellow R, AYR) wastewater (AYR, 200 mg L(-1); glucose, 1000 mg L(-1)). The ABR-BES was operated without and with external power supply to examine AYR reduction process and reductive intermediates with different external voltages (0.3, 0.5 and 0.7 V) and hydraulic retention times (HRT: 8, 6 and 4h). The decolorization efficiency in the ABR-BES (8h HRT, 0.5 V) was higher than that in ABR-BES without electrolysis, i.e. 95.1 ± 1.5% versus 86.9 ± 6.3%. Incorporation of BES with ABR accelerated the consumption of VFAs (mainly acetate) and attenuated biogas (methane) production. Higher power supply (0.7 V) enhanced AYR decolorization efficiency (96.4 ± 1.8%), VFAs removal, and current density (24.1 Am(-3) TCV). Shorter HRT increased volumetric AYR decolorization rates, but decreased AYR decolorization efficiency. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Heat transfer analysis of cylindrical anaerobic reactors with different sizes: a heat transfer model.

    PubMed

    Liu, Jiawei; Zhou, Xingqiu; Wu, Jiangdong; Gao, Wen; Qian, Xu

    2017-10-01

    The temperature is the essential factor that influences the efficiency of anaerobic reactors. During the operation of the anaerobic reactor, the fluctuations of ambient temperature can cause a change in the internal temperature of the reactor. Therefore, insulation and heating measures are often used to maintain anaerobic reactor's internal temperature. In this paper, a simplified heat transfer model was developed to study heat transfer between cylindrical anaerobic reactors and their surroundings. Three cylindrical reactors of different sizes were studied, and the internal relations between ambient temperature, thickness of insulation, and temperature fluctuations of the reactors were obtained at different reactor sizes. The model was calibrated by a sensitivity analysis, and the calibrated model was well able to predict reactor temperature. The Nash-Sutcliffe model efficiency coefficient was used to assess the predictive power of heat transfer models. The Nash coefficients of the three reactors were 0.76, 0.60, and 0.45, respectively. The model can provide reference for the thermal insulation design of cylindrical anaerobic reactors.

  17. Correlation Between Cycling Power and Muscle Thickness in Cyclists.

    PubMed

    Lee, Hyung-Jin; Lee, Kang-Woo; Lee, Yong-Woo; Kim, Hee-Jin

    2018-05-17

    The aim of this study was to determine the correlation between muscle thickness (MT) and cycling power in varsity cyclists using ultrasonography (US) and to identify any differences in MT between short- and long-distance cyclists. Twelve cyclists participated in this study. Real-time two-dimensional B-mode US was used to measure the MT in the anterior thigh, anterior lower leg, and trunk, especially in the abdominal and lumbar regions. A Wattbike cycle ergometer was used to measure cycling power parameters such as maximum anaerobic power (over 5 s), mean anaerobic power (over 30 s), and aerobic power (over 3 min). This study was approved by the Ethics Committee of Korea National Sports University. There was a significant relationship between the MT and cycling power for the rectus femoris (RF) and vastus lateralis (VL) in the thigh, the rectus abdominis (RA) in the abdominal region, and the erector spinae (ES) in the lower back. The MT values of the RF, VL, and ES were strongly associated with the maximum and mean anaerobic power. There were significant differences between short- and long-distance cyclists in the MT of the RF in the thigh, the RA, the external abdominal oblique, the internal abdominal oblique, and the transverse abdominis muscle in the abdomen. We suggest that training programs attempting to improve cycling performance focus on improving the VL and ES via resistance weight or cycle training and also the core muscles for short-distance cyclists. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  18. ANAEROBIC AND AEROBIC TREATMENT OF CHLORINATED ALIPHATIC COMPOUNDS

    EPA Science Inventory

    Biological degradation of 12 chlorinated aliphatic compounds (CACs) was assessed in bench-top reactors and in serum bottle tests. Three continuously mixed daily batch-fed reactor systems were evaluated: anaerobic, aerobic, and sequential-anaerobic-aerobic (sequential). Glucose,...

  19. The maximum specific hydrogen-producing activity of anaerobic mixed cultures: definition and determination

    PubMed Central

    Mu, Yang; Yang, Hou-Yun; Wang, Ya-Zhou; He, Chuan-Shu; Zhao, Quan-Bao; Wang, Yi; Yu, Han-Qing

    2014-01-01

    Fermentative hydrogen production from wastes has many advantages compared to various chemical methods. Methodology for characterizing the hydrogen-producing activity of anaerobic mixed cultures is essential for monitoring reactor operation in fermentative hydrogen production, however there is lack of such kind of standardized methodologies. In the present study, a new index, i.e., the maximum specific hydrogen-producing activity (SHAm) of anaerobic mixed cultures, was proposed, and consequently a reliable and simple method, named SHAm test, was developed to determine it. Furthermore, the influences of various parameters on the SHAm value determination of anaerobic mixed cultures were evaluated. Additionally, this SHAm assay was tested for different types of substrates and bacterial inocula. Our results demonstrate that this novel SHAm assay was a rapid, accurate and simple methodology for determining the hydrogen-producing activity of anaerobic mixed cultures. Thus, application of this approach is beneficial to establishing a stable anaerobic hydrogen-producing system. PMID:24912488

  20. The maximum specific hydrogen-producing activity of anaerobic mixed cultures: definition and determination

    NASA Astrophysics Data System (ADS)

    Mu, Yang; Yang, Hou-Yun; Wang, Ya-Zhou; He, Chuan-Shu; Zhao, Quan-Bao; Wang, Yi; Yu, Han-Qing

    2014-06-01

    Fermentative hydrogen production from wastes has many advantages compared to various chemical methods. Methodology for characterizing the hydrogen-producing activity of anaerobic mixed cultures is essential for monitoring reactor operation in fermentative hydrogen production, however there is lack of such kind of standardized methodologies. In the present study, a new index, i.e., the maximum specific hydrogen-producing activity (SHAm) of anaerobic mixed cultures, was proposed, and consequently a reliable and simple method, named SHAm test, was developed to determine it. Furthermore, the influences of various parameters on the SHAm value determination of anaerobic mixed cultures were evaluated. Additionally, this SHAm assay was tested for different types of substrates and bacterial inocula. Our results demonstrate that this novel SHAm assay was a rapid, accurate and simple methodology for determining the hydrogen-producing activity of anaerobic mixed cultures. Thus, application of this approach is beneficial to establishing a stable anaerobic hydrogen-producing system.

  1. The Effects of Exhaustive Exercise on Thermoregulatory Fatigue During Cold Exposure

    DTIC Science & Technology

    2002-04-01

    exercise routine for days 1-7 consisted of the following activities each day: running & sprinting (hiking substituted on D3 & D7), weightlifting ...ergometry, and an anaerobic power test. Subjects ran 4.8 km at their personal best and sprinted 800 m three consecutive times. Weightlifting consisted of one... injury on Day 5 and did not participate in the Day 7 cold exposure. The main reasons for not completing all 6 hours during CW included hip flexor

  2. An elliptical trainer may render the Wingate all-out test more anaerobic.

    PubMed

    Ozkaya, Ozgur; Colakoglu, Muzaffer; Kuzucu, Erinc O; Delextrat, Anne

    2014-03-01

    The purpose of this study was to evaluate the contribution of the 3 main energy pathways during a 30-second elliptical all-out test (EAT) compared with the Wingate all-out test (WAT). Participants were 12 male team sport players (age, 20.3 ± 1.8 years; body mass, 74.8 ± 12.4 kg; height, 176.0 ± 9.10 cm; body fat, 12.1 ± 1.0%). Net energy outputs from the oxidative, phospholytic, and glycolytic energy systems were calculated from oxygen uptake data recorded during 30-second test, the fast component of postexercise oxygen uptake kinetics, and peak blood lactate concentration, respectively. In addition, mechanical power indices were calculated. The main results showed that compared with WAT, EAT was characterized by significantly lower absolute and relative contributions of the oxidative system (16.9 ± 2.5 J vs. 19.8 ± 4.9 J; p ≤ 0.05 and 11.2 ± 1.5% vs. 15.7 ± 3.28%; p ≤ 0.001). In addition, significantly greater absolute and relative contributions of the phospholytic system (66.1 ± 15.8 J vs. 50.7 ± 15.9 J; p ≤ 0.01 and 43.8 ± 6.62% vs. 39.1 ± 6.87%; p ≤ 0.05) and a significantly greater absolute contribution of the glycolytic system (68.6 ± 18.4 J vs. 57.4 ± 13.7 J; p ≤ 0.01) were observed in EAT compared with WAT. Finally, all power indices, except the fatigue index, were significantly greater in EAT than WAT (p ≤ 0.05). Because of the significantly lower aerobic contribution in EAT compared with WAT, elliptical trainers may be a good alternative to cycle ergometers to assess anaerobic performance in athletes involved in whole-body activities.

  3. Microbiological analysis of infected root canals from symptomatic and asymptomatic teeth with periapical periodontitis and the antimicrobial susceptibility of some isolated anaerobic bacteria.

    PubMed

    Jacinto, R C; Gomes, B P F A; Ferraz, C C R; Zaia, A A; Filho, F J Souza

    2003-10-01

    The purpose of the present study was to investigate the correlation between the composition of the bacterial flora isolated from infected root canals of teeth with apical periodontitis with the presence of clinical signs and symptoms, and to test the antibiotic susceptibility of five anaerobic bacteria mostly commonly found in the root canals of symptomatic teeth against various substances using the E-test. Microbial samples were taken from 48 root canals, 29 symptomatic and 19 asymptomatic, using adequate techniques. A total of 218 cultivable isolates were recovered from 48 different microbial species and 19 different genera. Root canals from symptomatic teeth harbored more obligate anaerobes and a bigger number of bacterial species than the asymptomatic teeth. More than 70% of the bacterial isolates were strict anaerobes. Statistical analysis used a Pearson Chi-squared test or a one-sided Fisher's Exact test as appropriate. Suggested relationships were found between specific microorganisms, especially gram-negative anaerobes, and the presence of spontaneous or previous pain, tenderness to percussion, pain on palpation and swelling amoxicillin, amoxicillin + clavulanate and cephaclor were effective against all the strains tested. The lowest susceptibility rate was presented by Prevotella intermedia/nigrescens against Penicillin G. Our results suggested that specific bacteria are associated with endodontic symptoms of infected teeth with periapical periodontitis and the majority of the anaerobic bacterial species tested were susceptible to all antibiotics studied.

  4. Are eating habits associated with physical fitness in primary school children?

    PubMed

    Thivel, David; David, Thivel; Aucouturier, Julien; Julien, Aucouturier; Isacco, Laurie; Laurie, Isacco; Lazaar, Nordine; Nordine, Lazaar; Ratel, Sébastien; Sébastien, Ratel; Doré, Eric; Eric, Doré; Meyer, Martine; Martine, Meyer; Duché, Pascale; Pascale, Duché

    2013-01-01

    Children's eating habits have mainly been related to anthropometric characteristics but less is known about their association with physical fitness. 278 French school children (131 boys and 147 girls) filled in eating habit questionnaires and completed anthropometric measurement (weight, height, skinfolds) and physical fitness tests. The 20-m Shuttle run test and the Squat Jump test were used to assess aerobic fitness and anaerobic (lower limb muscle power) fitness respectively. Breakfast consumption was associated with both aerobic fitness (p<0.05) and lower limb muscle power (p<0.01) while snacking was negatively related to Squat Jump performances (p<0.05). There was no association between physical fitness and either the type of the consumed-beverages or TV watching during dinner and lunch meals. Cumulated unhealthy eating habits was negatively associated with CRF stages and lower limb muscle power performances (p<0.05). French primary school children physical fitness is associated with their eating habits and decreases with the number of unhealthy eating behaviors cumulated. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Anaerobic Metabolism: Linkages to Trace Gases and Aerobic Processes

    NASA Astrophysics Data System (ADS)

    Megonigal, J. P.; Hines, M. E.; Visscher, P. T.

    2003-12-01

    Life evolved and flourished in the absence of molecular oxygen (O2). As the O2 content of the atmosphere rose to the present level of 21% beginning about two billion years ago, anaerobic metabolism was gradually supplanted by aerobic metabolism. Anaerobic environments have persisted on Earth despite the transformation to an oxidized state because of the combined influence of water and organic matter. Molecular oxygen diffuses about 104 times more slowly through water than air, and organic matter supports a large biotic O2 demand that consumes the supply faster than it is replaced by diffusion. Such conditions exist in wetlands, rivers, estuaries, coastal marine sediments, aquifers, anoxic water columns, sewage digesters, landfills, the intestinal tracts of animals, and the rumen of herbivores. Anaerobic microsites are also embedded in oxic environments such as upland soils and marine water columns. Appreciable rates of aerobic respiration are restricted to areas that are in direct contact with air or those inhabited by organisms that produce O2.Rising atmospheric O2 reduced the global area of anaerobic habitat, but enhanced the overall rate of anaerobic metabolism (at least on an area basis) by increasing the supply of electron donors and acceptors. Organic carbon production increased dramatically, as did oxidized forms of nitrogen, manganese, iron, sulfur, and many other elements. In contemporary anaerobic ecosystems, nearly all of the reducing power is derived from photosynthesis, and most of it eventually returns to O2, the most electronegative electron acceptor that is abundant. This photosynthetically driven redox gradient has been thoroughly exploited by aerobic and anaerobic microorganisms for metabolism. The same is true of hydrothermal vents (Tunnicliffe, 1992) and some deep subsurface environments ( Chapelle et al., 2002), where thermal energy is the ultimate source of the reducing power.Although anaerobic habitats are currently a small fraction of Earth's surface area, they have a profound influence on the biogeochemistry of the planet. This is evident from the observation that the O2 and CH4 content of Earth's atmosphere are in extreme disequilibrium (Sagan et al., 1993). The combination of high aerobic primary production and anoxic sediments provided the large deposits of fossil fuels that have become vital and contentious sources of energy for modern industrialized societies. Anaerobic metabolism is responsible for the abundance of N2 in the atmosphere; otherwise N2-fixing bacteria would have consumed most of the N2 pool long ago (Schlesinger, 1997). Anaerobic microorganisms are common symbionts of termites, cattle, and many other animals, where they aid digestion. Nutrient and pollutant chemistry are strongly modified by the reduced conditions that prevail in wetland and aquatic ecosystems.This review of anaerobic metabolism emphasizes aerobic oxidation, because the two processes cannot be separated in a complete treatment of the topic. It is process oriented and highlights the fascinating microorganisms that mediate anaerobic biogeochemistry. We begin this review with a brief discussion of CO2 assimilation by autotrophs, the source of most of the reducing power on Earth, and then consider the biological processes that harness this potential energy. Energy liberation begins with the decomposition of organic macromolecules to relatively simple compounds, which are simplified further by fermentation. Methanogenesis is considered next because CH4 is a product of acetate fermentation, and thus completes the catabolism of organic matter, particularly in the absence of inorganic electron acceptors. Finally, the organisms that use nitrogen, manganese, iron, and sulfur for terminal electron acceptors are considered in order of decreasing free-energy yield of the reactions.

  6. How to isolate, identify and determine antimicrobial susceptibility of anaerobic bacteria in routine laboratories?

    PubMed

    Nagy, E; Boyanova, L; Justesen, U S

    2018-02-17

    There has been increased interest in the study of anaerobic bacteria that cause human infection during the past decade. Many new genera and species have been described using 16S rRNA gene sequencing of clinical isolates obtained from different infection sites with commercially available special culture media to support the growth of anaerobes. Several systems, such as anaerobic pouches, boxes, jars and chambers provide suitable anaerobic culture conditions to isolate even strict anaerobic bacteria successfully from clinical specimens. Beside the classical, time-consuming identification methods and automated biochemical tests, the use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has revolutionized identification of even unusual and slow-growing anaerobes directly from culture plates, providing the possibility of providing timely information about anaerobic infections. The aim of this review article is to present methods for routine laboratories, which carry out anaerobic diagnostics on different levels. Relevant data from the literature mostly published during the last 7 years are encompassed and discussed. The review involves topics on the anaerobes that are members of the commensal microbiota and their role causing infection, the key requirements for collection and transport of specimens, processing of specimens in the laboratory, incubation techniques, identification and antimicrobial susceptibility testing of anaerobic bacteria. Advantages, drawbacks and specific benefits of the methods are highlighted. The present review aims to update and improve anaerobic microbiology in laboratories with optimal conditions as well as encourage its routine implementation in laboratories with restricted resources. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  7. Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.

    PubMed

    Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari

    2014-07-01

    [Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.

  8. Utilization of biogas produced by anaerobic digestion of agro-industrial waste: Energy, economic and environmental effects.

    PubMed

    Hublin, Andrea; Schneider, Daniel Rolph; Džodan, Janko

    2014-07-01

    Anaerobic digestion of agro-industrial waste is of significant interest in order to facilitate a sustainable development of energy supply. Using of material and energy potentials of agro-industrial waste, in the framework of technical, economic, and ecological possibilities, contributes in increasing the share of energy generated from renewable energy sources. The paper deals with the benefits arising from the utilization of biogas produced by co-digestion of whey and cow manure. The advantages of this process are the profitability of the plant and the convenience in realizing an anaerobic digestion plant to produce biogas that is enabled by the benefits from the sale of electric energy at favorable prices. Economic aspects are related to the capital cost (€ 2,250,000) of anaerobic digestion treatment in a biogas plant with a 300 kW power and 510 kW heating unit in a medium size farm (450 livestock units). Considering the optimum biogas yield of 20.7 dm(3) kg(-1) of wet substrate and methane content in the biogas obtained of 79%, the anaerobic process results in a daily methane production of 2,500 kg, with the maximum power generation of 2,160,000 kWh y(-1) and heat generation of 2,400,000 kWh y(-1) The net present value (NPV), internal rate of return (IRR) and payback period for implementation of profitable anaerobic digestion process is evaluated. Ecological aspects related to carbon dioxide (CO2) and methane (CH4) emission reduction are assessed. © The Author(s) 2014.

  9. Impact of single anaerobic exercise on delayed activation of endothelial xanthine oxidase in men and women.

    PubMed

    Wiecek, Magdalena; Maciejczyk, Marcin; Szymura, Jadwiga; Kantorowicz, Malgorzata; Szygula, Zbigniew

    2017-11-01

    The aim of the study was to evaluate the activity of xanthine oxidase (XO) in the blood of men and women during the first hour following a single anaerobic exercise (AN-EX), and after 24 hours of recovery, and to determine whether the changes in XO activity in the blood after AN-EX are dependent on anaerobic performance. Ten men and ten women performed a single AN-EX. Blood was collected before and five times after completion of the AN-EX. The activity of XO was determined. In both groups, a significant (P < 0.05) increase in blood XO activity was found only 24 hours after the AN-EX. The increased activity of XO in men was significantly lower than in women (P < 0.05). Negative correlations were found between the increase in XO activity in the blood plasma 24 hours after the AN-EX and anaerobic power, the total work performed during the AN-EX and the power decrease. In the first hour after the single AN-EX, XO activity in the blood of women and men did not change, but after 24 hours of recovery, it was significantly higher compared to baseline levels in both sexes. Single AN-EX causes a smaller increase in XO activity in people with higher anaerobic performance.

  10. Techniques for controlling variability in gram staining of obligate anaerobes.

    PubMed Central

    Johnson, M J; Thatcher, E; Cox, M E

    1995-01-01

    Identification of anaerobes recovered from clinical samples is complicated by the fact that certain gram-positive anaerobes routinely stain gram negative; Peptostreptococcus asaccharolyticus, Eubacterium plautii, Clostridium ramosum, Clostridium symbiosum, and Clostridium clostridiiforme are among the nonconformists with regard to conventional Gram-staining procedures. Accurate Gram staining of American Type Culture Collection strains of these anaerobic bacteria is possible by implementing fixing and staining techniques within a gloveless anaerobic chamber. Under anaerobic conditions, gram-positive staining occurred in all test organisms with "quick" fixing techniques with both absolute methanol and formalin. The results support the hypothesis that, when anaerobic bacteria are exposed to oxygen, a breakdown of the physical integrity of the cell wall occurs, introducing Gram stain variability in gram-positive anaerobes. PMID:7538512

  11. A quasi-universal medium to break the aerobic/anaerobic bacterial culture dichotomy in clinical microbiology.

    PubMed

    Dione, N; Khelaifia, S; La Scola, B; Lagier, J C; Raoult, D

    2016-01-01

    In the mid-19th century, the dichotomy between aerobic and anaerobic bacteria was introduced. Nevertheless, the aerobic growth of strictly anaerobic bacterial species such as Ruminococcus gnavus and Fusobacterium necrophorum, in a culture medium containing antioxidants, was recently demonstrated. We tested aerobically the culture of 623 bacterial strains from 276 bacterial species including 82 strictly anaerobic, 154 facultative anaerobic, 31 aerobic and nine microaerophilic bacterial species as well as ten fungi. The basic culture medium was based on Schaedler agar supplemented with 1 g/L ascorbic acid and 0.1 g/L glutathione (R-medium). We successively optimized this media, adding 0.4 g/L uric acid, using separate autoclaving of the component, or adding haemin 0.1 g/L or α-ketoglutarate 2 g/L. In the basic medium, 237 bacterial species and ten fungal species grew but with no growth of 36 bacterial species, including 22 strict anaerobes. Adding uric acid allowed the growth of 14 further species including eight strict anaerobes, while separate autoclaving allowed the growth of all tested bacterial strains. To extend its potential use for fastidious bacteria, we added haemin for Haemophilus influenzae, Haemophilus parainfluenzae and Eikenella corrodens and α-ketoglutarate for Legionella pneumophila. This medium allowed the growth of all tested strains with the exception of Mycobacterium tuberculosis and Mycobacterium bovis. Testing primoculture and more fastidious species will constitute the main work to be done, but R-medium coupled with a rapid identification method (matrix-assisted laser desorption/ionization time-of-flight mass spectrometry) will facilitate the anaerobic culture in clinical microbiology laboratories. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shayya, Walid

    2007-03-20

    The state of New York through the New York State Energy Research and Development Authority (NYSERDA) has developed a suite of digester projects throughout the state to assess the potential for anaerobic digestion systems to improve manure management and concurrently produce energy through the production of heat and electrical power using the biogas produced from the digesters. Dairies comprise a significant part of the agribusiness and economy of the state of New York. Improving the energy efficiency and environmental footprint of dairies is a goal of NYSERDA. SUNY Morrisville State College (MSC) is part of a collection of state universities,more » dairy farms, cooperatives, and municipalities examining anaerobic digestion systems to achieve the goals of NYSERDA, the improvement of manure management, and reducing emissions to local dairy animal sites. The process for siting a digester system at the MSC’s free-stall Dairy Complex was initiated in 2002. The project involved the construction of an anaerobic digester that can accommodate the organic waste generated at Dairy complex located about a mile southeast of the main campus. Support for the project was provided through funding from the New York State Energy Research and Development Authority (NYSERDA) and the New York State Department of Agriculture and Markets. The DOE contribution to the project provided additional resources to construct an expanded facility to handle waste generated from the existing free-stall dairy and the newly-constructed barns. Construction on the project was completed in 2006 and the production of biogas started soon after the tanks were filled with the effluent generated at the Dairy Complex. The system has been in operation since December 17, 2006. The generated biogas was consistently flared starting from December 20, 2006, and until the operation of the internal combustion engine/generator set were first tested on the 9th of January, 2007. Flaring the biogas continued until the interconnect with the power grid was approved by NYSEG (the electrical power provider) and the combined heat and power generation (CHP) system was authorized to start on February 27, 2007. The system has been in operation since February 28, 2007, and is generating 45 to 50 kW of electrical power on continuous basis. The completed project will ultimately allow for investigating the facility of utilizing organic waste from a dairy operation in a hard-top plug-flow methane digester with the ultimate goal of reducing environmental risk, increasing economic benefits, and demonstrating the viability of an anaerobic methane digestion system. Many benefits are expected as a result of the completed project including our better understanding of the anaerobic digestion process and its management as well as the facility to utilize the methane digester as a demonstration site for dairy producers, farmers, and organic waste producers in New York State and the Northeast. Additional benefits include helping current and future students in dairy science and technology, agricultural business, environmental sciences, agricultural engineering, and other disciplines develop better understanding of underutilized biomass alternative energy technologies, environmental conservation, environmental stewardship, and sustainable agriculture.« less

  13. Fiscalini Farms Biomass Energy Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    William Stringfellow; Mary Kay Camarillo; Jeremy Hanlon

    2011-09-30

    In this final report describes and documents research that was conducted by the Ecological Engineering Research Program (EERP) at the University of the Pacific (Stockton, CA) under subcontract to Fiscalini Farms LP for work under the Assistance Agreement DE-EE0001895 'Measurement and Evaluation of a Dairy Anaerobic Digestion/Power Generation System' from the United States Department of Energy, National Energy Technology Laboratory. Fiscalini Farms is operating a 710 kW biomass-energy power plant that uses bio-methane, generated from plant biomass, cheese whey, and cattle manure via mesophilic anaerobic digestion, to produce electricity using an internal combustion engine. The primary objectives of the projectmore » were to document baseline conditions for the anaerobic digester and the combined heat and power (CHP) system used for the dairy-based biomass-energy production. The baseline condition of the plant was evaluated in the context of regulatory and economic constraints. In this final report, the operation of the plant between start-up in 2009 and operation in 2010 are documented and an interpretation of the technical data is provided. An economic analysis of the biomass energy system was previously completed (Appendix A) and the results from that study are discussed briefly in this report. Results from the start-up and first year of operation indicate that mesophilic anaerobic digestion of agricultural biomass, combined with an internal combustion engine, is a reliable source of alternative electrical production. A major advantage of biomass energy facilities located on dairy farms appears to be their inherent stability and ability to produce a consistent, 24 hour supply of electricity. However, technical analysis indicated that the Fiscalini Farms system was operating below capacity and that economic sustainability would be improved by increasing loading of feedstocks to the digester. Additional operational modifications, such as increased utilization of waste heat and better documentation of potential of carbon credits, would also improve the economic outlook. Analysis of baseline operational conditions indicated that a reduction in methane emissions and other greenhouse gas savings resulted from implementation of the project. The project results indicate that using anaerobic digestion to produce bio-methane from agricultural biomass is a promising source of electricity, but that significant challenges need to be addressed before dairy-based biomass energy production can be fully integrated into an alternative energy economy. The biomass energy facility was found to be operating undercapacity. Economic analysis indicated a positive economic sustainability, even at the reduced power production levels demonstrated during the baseline period. However, increasing methane generation capacity (via the importation of biomass codigestate) will be critical for increasing electricity output and improving the long-term economic sustainability of the operation. Dairy-based biomass energy plants are operating under strict environmental regulations applicable to both power-production and confined animal facilities and novel approached are being applied to maintain minimal environmental impacts. The use of selective catalytic reduction (SCR) for nitrous oxide control and a biological hydrogen sulfide control system were tested at this facility. Results from this study suggest that biomass energy systems can be compliant with reasonable scientifically based air and water pollution control regulations. The most significant challenge for the development of biomass energy as a viable component of power production on a regional scale is likely to be the availability of energy-rich organic feedstocks. Additionally, there needs to be further development of regional expertise in digester and power plant operations. At the Fiscalini facility, power production was limited by the availability of biomass for methane generation, not the designed system capacity. During the baseline study period, feedstocks included manure, sudan grass silage, and refused-feed. The ability of the dairy to produce silage in excess of on-site feed requirements limited power production. The availability of biomass energy crops and alternative feedstocks, such as agricultural and food wastes, will be a major determinant to the economic and environmental sustainability of biomass based electricity production.« less

  14. Test/QA Plan For Verification Of Anaerobic Digester For Energy Production And Pollution Prevention

    EPA Science Inventory

    The ETV-ESTE Program conducts third-party verification testing of commercially available technologies that improve the environmental conditions in the U.S. A stakeholder committee of buyers and users of such technologies guided the development of this test on anaerobic digesters...

  15. Adaptive Changes After 2 Weeks of 10-s Sprint Interval Training With Various Recovery Times.

    PubMed

    Olek, Robert A; Kujach, Sylwester; Ziemann, Ewa; Ziolkowski, Wieslaw; Waz, Piotr; Laskowski, Radoslaw

    2018-01-01

    Purpose: The aim of this study was to compare the effect of applying two different rest recovery times in a 10-s sprint interval training session on aerobic and anaerobic capacities as well as skeletal muscle enzyme activities. Methods: Fourteen physically active but not highly trained male subjects (mean maximal oxygen uptake 50.5 ± 1.0 mlO 2 ·kg -1 ·min -1 ) participated in the study. The training protocol involved a series of 10-s sprints separated by either 1-min (SIT10:1) or 4-min (SIT10:4) of recovery. The number of sprints progressed from four to six over six sessions separated by 1-2 days rest. Pre and post intervention anthropometric measurements, assessment of aerobic, anaerobic capacity and muscle biopsy were performed. In the muscle samples maximal activities of citrate synthase (CS), 3-hydroxyacylCoA dehydrogenase (HADH), carnitine palmitoyl-transferase (CPT), malate dehydrogenase (MDH), and its mitochondrial form (mMDH), as well as lactate dehydrogenase (LDH) were determined. Analysis of variance was performed to determine changes between conditions. Results: Maximal oxygen uptake improved significantly in both training groups, by 13.6% in SIT10:1 and 11.9% in SIT10:4, with no difference between groups. Wingate anaerobic test results indicated main effect of time for total work, peak power output and mean power output, which increased significantly and similarly in both groups. Significant differences between training groups were observed for end power output, which increased by 10.8% in SIT10:1, but remained unchanged in SIT10:4. Both training protocols induced similar increase in CS activity (main effect of time p < 0.05), but no other enzymes. Conclusion: Sprint interval training protocols induce metabolic adaptation over a short period of time, and the reduced recovery between bouts may attenuate fatigue during maximal exercise.

  16. Training reduces catabolic and inflammatory response to a single practice in female volleyball players.

    PubMed

    Eliakim, Alon; Portal, Shawn; Zadik, Zvi; Meckel, Yoav; Nemet, Dan

    2013-11-01

    We examined the effect of training on hormonal and inflammatory response to a single volleyball practice in elite adolescent players. Thirteen female, national team level, Israeli volleyball players (age 16.0 ± 1.4 years, Tanner stage 4-5) participated in the study. Blood samples were collected before and immediately after a typical 60 minutes of volleyball practice, before and after 7 weeks of training during the initial phase of the season. Training involved tactic and technical drills (20% of time), power and speed drills (25% of time), interval sessions (25% of time), endurance-type training (15% of time), and resistance training (15% of time). To achieve greater training responses, the study was performed during the early phase (first 7 weeks) of the volleyball season. Hormonal measurements included the anabolic hormones growth hormone (GH), insulin-like growth factor-I (IGF-I) and IGF-binding protein-3, the catabolic hormone cortisol, the proinflammatory marker interleukin-6 (IL-6), and the anti-inflammatory marker IL-1 receptor antagonist. Training led to a significant improvement of vertical jump, anaerobic properties (peak and mean power by the Wingate Anaerobic Test), and predicted VO2max (by the 20-m shuttle run). Volleyball practice, both before and after the training intervention, was associated with a significant increase of serum lactate, GH, and IL-6. Training resulted in a significantly reduced cortisol response ([INCREMENT]cortisol: 4.2 ± 13.7 vs. -4.4 ± 12.3 ng · ml, before and after training, respectively; p < 0.02), and IL-6 response ([INCREMENT]IL-6: 1.3 ± 1.0 vs. 0.3 ± 0.4 pg · ml, before and after training, respectively; p < 0.01) to the same relative intensity volleyball practice. The results suggest that along with the improvement of power and anaerobic and aerobic characteristics, training reduces the catabolic and inflammatory response to exercise.

  17. Ultrasound pretreatment for enhanced biogas production from olive mill wastewater.

    PubMed

    Oz, Nilgun Ayman; Uzun, Alev Cagla

    2015-01-01

    This study investigates applicability of low frequency ultrasound technology to olive mill wastewaters (OMWs) as a pretreatment step prior to anaerobic batch reactors to improve biogas production and methane yield. OMWs originating from three phase processes are characterized with high organic content and complex nature. The treatment of the wastewater is problematic and alternative treatment options should be investigated. In the first part of the study, OMW samples were subjected to ultrasound at a frequency of 20kHz with applied powers varying between 50 and 100W under temperature controlled conditions for different time periods in order to determine the most effective sonication conditions. The level of organic matter solubilization at ultrasound experiments was assessed by calculating the ratio of soluble chemical oxygen demand/total chemical oxygen demand (SCOD/TCOD). The results revealed that the optimum ultrasonic condition for diluted OMW is 20kHz, 0.4W/mL for 10min. The application of ultrasound to OMW increased SCOD/TCOD ratio from 0.59 to 0.79. Statistical analysis (Friedman's tests) show that ultrasound was significantly effective on diluted OMW (p<0.05) in terms of SCOD parameter, but not for raw OMW (p>0.05). For raw OMW, this increase has been found to be limited due to high concentration of suspended solids (SS). In the second part of the study, biogas and methane production rates of anaerobic batch reactor fed with the ultrasound pretreated OMW samples were compared with the results of control reactor fed with untreated OMW in order to determine the effect of sonication. A nonparametric statistical procedure, Mann-Whitney U test, was used to compare biogas and methane production from anaerobic batch reactors for control and ultrasound pretreated samples. Results showed that application of low frequency ultrasound to OMW significantly improved both biogas and methane production in anaerobic batch reactor fed with the wastewater (p<0.05). Anaerobic batch reactor fed with ultrasound pretreated diluted OMW produced approximately 20% more biogas and methane compared with the untreated one (control reactor). The overall results indicated that low frequency ultrasound pretreatment increased soluble COD in OMW and subsequently biogas production. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Attack on Lignified Grass Cell Walls by a Facultatively Anaerobic Bacterium

    PubMed Central

    Akin, Danny E.

    1980-01-01

    A filamentous, facultatively anaerobic microorganism that attacked lignified tissue in forage grasses was isolated from rumen fluid with a Bermuda grass-containing anaerobic medium in roll tubes. The microbe, designated 7-1, demonstrated various colony and cellular morphologies under different growth conditions. Scanning electron microscopy revealed that 7-1 attacked lignified cell walls in aerobic and anaerobic culture. 7-1 predominately degraded tissues reacting positively for lignin with the chlorine-sulfite stain (i.e., sclerenchyma in leaf blades and parenchyma in stems) rather than the more resistant acid phloroglucinol-positive tissues (i.e., lignified vascular tissue and sclerenchyma ring in stems), although the latter tissues were occasionally attacked. Turbidimetric tests showed that 7-1 in anaerobic culture grew optimally at 39°C at a pH of 7.4 to 8.0. Tests for growth on plant cell wall carbohydrates showed that 7-1 grew on xylan and pectin slowly in aerobic cultures but not with pectin and only slightly with xylan in anaerobic culture. 7-1 was noncellulolytic as shown by filter paper tests. The microbe used the phenolic acids sinapic, ferulic, and p-coumaric acids as substrates for growth; the more highly methoxylated acids were used more effectively. Images PMID:16345651

  19. The effect of HMB supplementation on body composition, fitness, hormonal and inflammatory mediators in elite adolescent volleyball players: a prospective randomized, double-blind, placebo-controlled study.

    PubMed

    Portal, Shawn; Zadik, Zvi; Rabinowitz, Jonathan; Pilz-Burstein, Ruty; Adler-Portal, Dana; Meckel, Yoav; Cooper, Dan M; Eliakim, Alon; Nemet, Dan

    2011-09-01

    The use of ergogenic nutritional supplements is becoming inseparable from competitive sports. β-Hydroxy-β-Methylbutyric acid (HMB) has recently been suggested to promote fat-free mass (FFM) and strength gains during resistance training in adults. In this prospective randomized, double-blind, placebo-controlled study, we studied the effect of HMB (3 g/day) supplementation on body composition, muscle strength, anaerobic and aerobic capacity, anabolic/catabolic hormones and inflammatory mediators in elite, national team level adolescent volleyball players (13.5-18 years, 14 males, 14 females, Tanner stage 4-5) during the first 7 weeks of the training season. HMB led to a significant greater increase in FFM by skinfold thickness (56.4 ± 10.2 to 56.3 ± 8.6 vs. 59.3 ± 11.3 to 61.6 ± 11.3 kg in the control and HMB group, respectively, p < 0.001). HMB led to a significant greater increase in both dominant and non-dominant knee flexion isokinetic force/FFM, measured at fast (180°/sec) and slow (60°/sec) angle speeds, but had no significant effect on knee extension and elbow flexion and extension. HMB led to a significant greater increase in peak and mean anaerobic power determined by the Wingate anaerobic test (peak power: 15.5 ± 1.6 to 16.2 ± 1.2 vs. 15.4 ± 1.6 to 17.2 ± 1.2 watts/FFM, mean power: 10.6 ± 0.9 to 10.8 ± 1.1 vs. 10.7 ± 0.8 to 11.8 ± 1.0 watts/FFM in control and HMB group, respectively, p < 0.01), with no effect on fatigue index. HMB had no significant effect on aerobic fitness or on anabolic (growth hormone, IGF-I, testosterone), catabolic (cortisol) and inflammatory mediators (IL-6 and IL-1 receptor antagonist). HMB supplementation was associated with greater increases in muscle mass, muscle strength and anaerobic properties with no effect on aerobic capacity suggesting some advantage for its use in elite adolescent volleyball players during the initial phases of the training season. These effects were not accompanied by hormonal and inflammatory mediator changes.

  20. Effects of sprint interval training and body weight reduction on power to weight ratio in experienced cyclists.

    PubMed

    Lunn, William R; Finn, Joan A; Axtell, Robert S

    2009-07-01

    The purpose of this study was to determine the effect of supramaximal sprint interval training (SIT), body weight reduction, and a combination of both treatments on peak and average anaerobic power to weight ratio (PPOan:Wt, APOan:Wt) by manipulating peak and average anaerobic power output (PPOan, APOan) and body weight (BW) in experienced cyclists. Participants (N = 34, age = 38.0 +/- 7.1 years) were assigned to 4 groups for a 10-week study. One group performed twice-weekly SIT sessions on a cycle ergometer while maintaining body weight (SIT). A second group did not perform SIT but intentionally reduced body weight (WR). A third group simultaneously performed SIT sessions and reduced body weight (SIT+WR). A control group cycled in their normal routine and maintained body weight (CON). The 30-second Wingate Test assessed pretest and posttest POan:Wt scores. There was a significant mean increase (p < 0.05) from pretest to posttest in PPOan:Wt and APOan:Wt (W x kg(-1)) scores in both SIT (10.82 +/- 1.71 to 11.92 +/- 1.77 and 8.05 +/- 0.64 to 8.77 +/- 0.64, respectively) and WR (10.33 +/- 2.91 to 11.29 +/- 2.80 and 7.04 +/- 1.45 to 7.62 +/- 1.24, respectively). PPOan and APOan (W) increased significantly only in SIT (753.7 +/- 121.0 to 834.3 +/- 150.1 and 561.3 +/- 62.5 to 612.7 +/- 69.0, respectively). Body weight (kg) decreased significantly in WR and SIT + WR (80.3 +/- 13.7 to 75.3 +/- 11.9 and 78.9 +/- 10.8 to 73.4 +/- 10.8, respectively). The results demonstrate that cyclists can use SIT sessions and body weight reduction as singular training interventions to effect significant increases in anaerobic power to weight ratio, which has been correlated to enhanced aerobic cycling performance. However, the treatments were not effective as combined interventions, as there was no significant change in either PPOan:Wt or APOan:Wt in SIT + WR.

  1. Evaluation of the routine antimicrobial susceptibility testing results of clinically significant anaerobic bacteria in a Slovenian tertiary-care hospital in 2015.

    PubMed

    Jeverica, Samo; Kolenc, Urša; Mueller-Premru, Manica; Papst, Lea

    2017-10-01

    The aim of our study was to determined antimicrobial susceptibility profiles of 2673 clinically significant anaerobic bacteria belonging to the major genera, isolated in 2015 in a large tertiary-care hospital in Slovenia. The species identification was performed by MALDI-TOF mass spectrometry. Antimicrobial susceptibility was determined immediately at the isolation of the strains against: penicillin, co-amoxiclav, imipenem, clindamycin and metronidazole, using gradient diffusion methodology and EUCAST breakpoints. The most frequent anaerobes were Bacteroides fragilis group with 31% (n = 817), Gram positive anaerobic cocci (GPACs) with 22% (n = 589), Prevotella with 14% (n = 313) and Propionibacterium with 8% (n = 225). Metronidazole has retained full activity (100%) against all groups of anaerobic bacteria intrinsically susceptible to it. Co-amoxiclav and imipenem were active against most tested anaerobes with zero or low resistance rates. However, observed resistance to co-amoxiclav (8%) and imipenem (1%) is worrying especially among B. fragilis group isolates. High overall resistance (23%) to clindamycin was detected in our study and was highest among the genera Prevotella, Bacteroides, Parabacteroides, GPACs and Clostridium. Routine testing of antimicrobial susceptibility of clinically relevant anaerobic bacteria is feasible and provides good surveillance data. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Sex-Related Differences in Self-Paced All Out High-Intensity Intermittent Cycling: Mechanical and Physiological Responses

    PubMed Central

    Panissa, Valéria L. G.; Julio, Ursula F.; França, Vanessa; Lira, Fabio S.; Hofmann, Peter; Takito, Monica Y.; Franchini, Emerson

    2016-01-01

    The purpose of this study was to compare sex-related responses to a self-paced all out high-intensity intermittent exercise (HIIE). 9 women and 10 men were submitted to a maximal incremental test (to determine maximum aerobic power - MAP and VO2peak), and an HIIE cycling (60x8s:12s, effort:pause). During the protocol the mean value of V̇O2 and heart rate for the entire exercise (VO2total and HRtotal) as well as the values only in the effort or pause (V̇O2effort, VO2pause and HReffort and HRpause) relative to VO2peak were measured. Anaerobic power reserve (APR), blood lactate [La] and the respiratory exchange ratio (RER) were also measured. These variables were compared between men and women using the unpaired t test. Men used greater APR (109 ± 12%MAP vs 92 ± 6%MAP) with similar V̇O2total (74 ± 7 vs 78 ± 8% VO2peak), however, when effort and pause were analysed separately, V̇O2effort (80 ± 9 vs 80 ± 5%VO2peak) was similar between sexes, while V̇O2pause was lower in men (69 ± 6% vs 77 ± 11% VO2peak, respectively). Women presented lower power decrement (30 ± 11 vs 11 ± 3%), RER (1.04 ± 0.03 vs 1.00 ± 0.02) and [La]peak (8.6 ± 0.9 vs 5.9 ± 2.3 mmol.L-1). Thus, we can conclude that men self-paced HIIE at higher APR but with the same cardiovascular/aerobic solicitation as women. Key points Men self-paced high-intensity intermittent exercise at higher intensities than women. Men utilized greater anaerobic power reserve than women. Men and women had same cardiovascular solicitation. PMID:27274678

  3. Performance of an anaerobic membrane bioreactor for pharmaceutical wastewater treatment.

    PubMed

    Svojitka, Jan; Dvořák, Lukáš; Studer, Martin; Straub, Jürg Oliver; Frömelt, Heinz; Wintgens, Thomas

    2017-04-01

    Anaerobic treatment of wastewater and waste organic solvents originating from the pharmaceutical and chemical industries was tested in a pilot anaerobic membrane bioreactor, which was operated for 580days under different operational conditions. The goal was to test the long-term treatment efficiency and identify inhibitory factors. The highest COD removal of up to 97% was observed when the influent concentration was increased by the addition of methanol (up to 25gL -1 as COD). Varying and generally lower COD removal efficiency (around 78%) was observed when the anaerobic membrane bioreactor was operated with incoming pharmaceutical wastewater as sole carbon source. The addition of waste organic solvents (>2.5gL -1 as COD) to the influent led to low COD removal efficiency or even to the breakdown of anaerobic digestion. Changes in the anaerobic population (e.g., proliferation of the genus Methanosarcina) resulting from the composition of influent were observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. The physiology of mountain biking.

    PubMed

    Impellizzeri, Franco M; Marcora, Samuele M

    2007-01-01

    Mountain biking is a popular outdoor recreational activity and an Olympic sport. Cross-country circuit races have a winning time of approximately equal 120 minutes and are performed at an average heart rate close to 90% of the maximum, corresponding to 84% of maximum oxygen uptake (VO2max). More than 80% of race time is spent above the lactate threshold. This very high exercise intensity is related to the fast starting phase of the race; the several climbs, forcing off-road cyclists to expend most of their effort going against gravity; greater rolling resistance; and the isometric contractions of arm and leg muscles necessary for bike handling and stabilisation. Because of the high power output (up to 500W) required during steep climbing and at the start of the race, anaerobic energy metabolism is also likely to be a factor of off-road cycling and deserves further investigation. Mountain bikers' physiological characteristics indicate that aerobic power (VO2max >70 mL/kg/min) and the ability to sustain high work rates for prolonged periods of time are prerequisites for competing at a high level in off-road cycling events. The anthropometric characteristics of mountain bikers are similar to climbers and all-terrain road cyclists. Various parameters of aerobic fitness are correlated to cross-country performance, suggesting that these tests are valid for the physiological assessment of competitive mountain bikers, especially when normalised to body mass. Factors other than aerobic power and capacity might influence off-road cycling performance and require further investigation. These include off-road cycling economy, anaerobic power and capacity, technical ability and pre-exercise nutritional strategies.

  5. The aerobic activity of metronidazole against anaerobic bacteria.

    PubMed

    Dione, Niokhor; Khelaifia, Saber; Lagier, Jean-Christophe; Raoult, Didier

    2015-05-01

    Recently, the aerobic growth of strictly anaerobic bacteria was demonstrated using antioxidants. Metronidazole is frequently used to treat infections caused by anaerobic bacteria; however, to date its antibacterial activity was only tested in anaerobic conditions. Here we aerobically tested using antioxidants the in vitro activities of metronidazole, gentamicin, doxycycline and imipenem against 10 common anaerobic and aerobic bacteria. In vitro susceptibility testing was performed by the disk diffusion method, and minimum inhibitory concentrations (MICs) were determined by Etest. Aerobic culture of the bacteria was performed at 37°C using Schaedler agar medium supplemented with 1mg/mL ascorbic acid and 0.1mg/mL glutathione; the pH was adjusted to 7.2 by 10M KOH. Growth of anaerobic bacteria cultured aerobically using antioxidants was inhibited by metronidazole after 72h of incubation at 37°C, with a mean inhibition diameter of 37.76mm and an MIC of 1μg/mL; however, strains remained non-sensitive to gentamicin. No growth inhibition of aerobic bacteria was observed after 24h of incubation at 37°C with metronidazole; however, inhibition was observed with doxycycline and imipenem used as controls. These results indicate that bacterial sensitivity to metronidazole is not related to the oxygen tension but is a result of the sensitivity of the micro-organism. In future, both culture and antibiotic susceptibility testing of strictly anaerobic bacteria will be performed in an aerobic atmosphere using antioxidants in clinical microbiology laboratories. Copyright © 2015 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  6. Aerobic and anaerobic biosynthesis of nano-selenium for remediation of mercury contaminated soil.

    PubMed

    Wang, Xiaonan; Zhang, Daoyong; Pan, Xiangliang; Lee, Duu-Jong; Al-Misned, Fahad A; Mortuza, M Golam; Gadd, Geoffrey Michael

    2017-03-01

    Selenium (Se) nanoparticles are often synthesized by anaerobes. However, anaerobic bacteria cannot be directly applied for bioremediation of contaminated top soil which is generally aerobic. In this study, a selenite-reducing bacterium, Citrobacter freundii Y9, demonstrated high selenite reducing power and produced elemental nano-selenium nanoparticles (nano-Se 0 ) under both aerobic and anaerobic conditions. The biogenic nano-Se 0 converted 45.8-57.1% and 39.1-48.6% of elemental mercury (Hg 0 ) in the contaminated soil to insoluble mercuric selenide (HgSe) under anaerobic and aerobic conditions, respectively. Addition of sodium dodecyl sulfonate enhanced Hg 0 remediation, probably owing to the release of intracellular nano-Se 0 from the bacterial cells for Hg fixation. The reaction product after remediation was identified as non-reactive HgSe that was formed by amalgamation of nano-Se 0 and Hg 0 . Biosynthesis of nano-Se 0 both aerobically and anaerobically therefore provides a versatile and cost-effective remediation approach for Hg 0 -contaminated surface and subsurface soils, where the redox potential often changes dramatically. Copyright © 2016. Published by Elsevier Ltd.

  7. A self-sustaining high-strength wastewater treatment system using solar-bio-hybrid power generation.

    PubMed

    Bustamante, Mauricio; Liao, Wei

    2017-06-01

    This study focuses on system analysis of a self-sustaining high-strength wastewater treatment concept combining solar technologies, anaerobic digestion, and aerobic treatment to reclaim water. A solar bio-hybrid power generation unit was adopted to power the wastewater treatment. Concentrated solar power (CSP) and photovoltaics (PV) were combined with biogas energy from anaerobic digestion. Biogas is also used to store the extra energy generated by the hybrid power unit and ensure stable and continuous wastewater treatment. It was determined from the energy balance analysis that the PV-bio hybrid power unit is the preferred energy unit to realize the self-sustaining high-strength wastewater treatment. With short-term solar energy storage, the PV-bio-hybrid power unit in Phoenix, AZ requires solar collection area (4032m 2 ) and biogas storage (35m 3 ), while the same unit in Lansing, MI needs bigger solar collection area and biogas storage (5821m 2 and 105m 3 , respectively) due to the cold climate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Prediction of performance on the RCMP physical ability requirement evaluation.

    PubMed

    Stanish, H I; Wood, T M; Campagna, P

    1999-08-01

    The Royal Canadian Mounted Police use the Physical Ability Requirement Evaluation (PARE) for screening applicants. The purposes of this investigation were to identify those field tests of physical fitness that were associated with PARE performance and determine which most accurately classified successful and unsuccessful PARE performers. The participants were 27 female and 21 male volunteers. Testing included measures of aerobic power, anaerobic power, agility, muscular strength, muscular endurance, and body composition. Multiple regression analysis revealed a three-variable model for males (70-lb bench press, standing long jump, and agility) explaining 79% of the variability in PARE time, whereas a one-variable model (agility) explained 43% of the variability for females. Analysis of the classification accuracy of the males' data was prohibited because 91% of the males passed the PARE. Classification accuracy of the females' data, using logistic regression, produced a two-variable model (agility, 1.5-mile endurance run) with 93% overall classification accuracy.

  9. Non-invasive indices for the estimation of the anaerobic threshold of oarsmen.

    PubMed

    Erdogan, A; Cetin, C; Karatosun, H; Baydar, M L

    2010-01-01

    This study compared four common non-invasive indices with an invasive index for determining the anaerobic threshold (AT) in 22 adult male rowers using a Concept2 rowing ergometer. A criterion-standard progressive incremental test (invasive method) measured blood lactate concentrations to determine the 4 mmol/l threshold (La4-AT) and Dmax AT (Dm-AT). This was compared with three indices obtained by analysis of respiratory gases and one that was based on the heart rate (HR) deflection point (HRDP) all of which used the Conconi test (non-invasive methods). In the Conconi test, the HRDP was determined whilst continuously increasing the power output (PO) by 25 W/min and measuring respiratory gases and HR. The La4-AT and Dm-AT values differed slightly with respect to oxygen uptake, PO and HR however, AT values significantly correlated with each other and with the four non-invasive methods. In conclusion, the non-invasive indices were comparable with the invasive index and could, therefore, be used in the assessment of AT during rowing ergometer use. In this population of elite rowers, Conconi threshold (Con-AT), based on the measurement of HRDP tended to be the most adequate way of estimating AT for training regulation purposes.

  10. Body-mass dependence of age-related deterioration in human muscular function.

    PubMed

    Meltzer, D E

    1996-04-01

    Maximal anaerobic power of human muscles declines with increasing chronological age and is correlated with body mass. This study investigated whether the rate of deterioration in human muscular function among trained weight lifters is also correlated with body mass. Cross-sectional analysis of performance data of over 1,100 Masters competitors in Olympic-style weight lifting was carried out; eight body-weight classes and six age groups were represented. Two-lift total data (sum of snatch and clean and jerk lifts) were analyzed. Mean deterioration rates in the performance of athletes of widely diverse body masses were compared over the following age ranges: 42-57, 42-62, and 42-67 yr. No statistically significant correlation (P < 0.05) was found between rate of performance decline and body mass. The relationship between body mass and the magnitude of age-related variation of deterioration rate was also studied; no significant correlation was found. Previous studies have demonstrated that performance in Olympic-style weight lifting is correlated with maximal anaerobic muscular power. This leads us to suggest that the age-related deterioration rate of anaerobic power in trained subjects may not be correlated with the body mass of the individual.

  11. 40 CFR 98.464 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Determine DOC value of a waste stream by either using at least a 60-day anaerobic biodegradation test as... biodegradation test and determine the DOC value of a waste stream following the procedures and requirements in...-based standards organization to conduct a minimum of a 60-day anaerobic biodegradation test. Consensus...

  12. The Effects of Bicycle Frame Geometry on Muscle Activation and Power During a Wingate Anaerobic Test

    PubMed Central

    Ricard, Mark D.; Hills-Meyer, Patrick; Miller, Michael G.; Michael, Timothy J.

    2006-01-01

    The purpose of this study was to compare the effects of bicycle seat tube angles (STA) of (72° and 82°) on power production and EMG of the vastus laeralis (VL), vastus medialis (VM), semimembranous (SM), biceps femoris (BF) during a Wingate test (WAT). Twelve experienced cyclists performed a WAT at each STA. Repeated measures ANOVA was used to identify differences in muscular activation by STA. EMG variables were normalized to isometric maximum voluntary contraction (MVC). Paired t-tests were used to test the effects of STA on: peak power, average power, minimum power and percent power drop. Results indicated BF activation was significantly lower at STA 82° (482.9 ± 166.6 %MVC·s) compared to STA 72° (712.6 ± 265.6 %MVC·s). There were no differences in the power variables between STAs. The primary finding was that increasing the STA from 72° to 82° enabled triathletes’ to maintain power production, while significantly reducing the muscular activation of the biceps femoris muscle. Key Points Road cyclists claim that bicycle seat tube angles between 72° and 76° are most effective for optimal performance in racing. Triathletes typically use seat tube angles greater than 76°. It is thought that a seat tube angle greater than 76° facilitates a smoother bike to run transition in the triathlon. Increasing the seat tube angle from 72 to 82 enabled triathletes’ to maintain power production, while significantly reducing the muscular activation of the biceps femoris muscle. Reduced hamstring muscular activation in the triathlon frame (82 seat tube angle) may serve to reduce hamstring tightness following the bike phase of the triathlon, allowing the runner to use a longer stride length. PMID:24198678

  13. Engineering a synthetic anaerobic respiration for reduction of xylose to xylitol using NADH output of glucose catabolism by Escherichia coli AI21.

    PubMed

    Iverson, Andrew; Garza, Erin; Manow, Ryan; Wang, Jinhua; Gao, Yuanyuan; Grayburn, Scott; Zhou, Shengde

    2016-04-16

    Anaerobic rather than aerobic fermentation is preferred for conversion of biomass derived sugars to high value redox-neutral and reduced commodities. This will likely result in a higher yield of substrate to product conversion and decrease production cost since substrate often accounts for a significant portion of the overall cost. To this goal, metabolic pathway engineering has been used to optimize substrate carbon flow to target products. This approach works well for the production of redox neutral products such as lactic acid from redox neutral sugars using the reducing power NADH (nicotinamide adenine dinucleotide, reduced) generated from glycolysis (2 NADH per glucose equivalent). Nevertheless, greater than two NADH per glucose catabolized is needed for the production of reduced products (such as xylitol) from redox neutral sugars by anaerobic fermentation. The Escherichia coli strain AI05 (ΔfrdBC ΔldhA ΔackA Δ(focA-pflB) ΔadhE ΔptsG ΔpdhR::pflBp 6-(aceEF-lpd)), previously engineered for reduction of xylose to xylitol using reducing power (NADH equivalent) of glucose catabolism, was further engineered by 1) deleting xylAB operon (encoding for xylose isomerase and xylulokinase) to prevent xylose from entering the pentose phosphate pathway; 2) anaerobically expressing the sdhCDAB-sucABCD operon (encoding for succinate dehydrogenase, α-ketoglutarate dehydrogenase and succinyl-CoA synthetase) to enable an anaerobically functional tricarboxcylic acid cycle with a theoretical 10 NAD(P)H equivalent per glucose catabolized. These reducing equivalents can be oxidized by synthetic respiration via xylose reduction, producing xylitol. The resulting strain, AI21 (pAI02), achieved a 96 % xylose to xylitol conversion, with a yield of 6 xylitol per glucose catabolized (molar yield of xylitol per glucose consumed (YRPG) = 6). This represents a 33 % improvement in xylose to xylitol conversion, and a 63 % increase in xylitol yield per glucose catabolized over that achieved by AI05 (pAI02). Increasing reducing power (NADH equivalent) output per glucose catabolized was achieved by anaerobic expression of both the pdh operon (pyruvate dehydrogenase) and the sdhCDAB-sucABCD operon, resulting in a strain capable of generating 10 NADH equivalent per glucose under anaerobic condition. The new E. coli strain AI21 (pAI02) achieved an actual 96 % conversion of xylose to xylitol (via synthetic respiration), and 6 xylitol (from xylose) per glucose catabolized (YRPG = 6, the highest known value). This strategy can be used to engineer microbial strains for the production of other reduced products from redox neutral sugars using glucose as a source of reducing power.

  14. Relationship of aerobic and anaerobic parameters with 400 m front crawl swimming performance

    PubMed Central

    Kalva-Filho, CA; Campos, EZ; Andrade, VL; Silva, ASR; Zagatto, AM; Lima, MCS

    2015-01-01

    The aims of the present study were to investigate the relationship of aerobic and anaerobic parameters with 400 m performance, and establish which variable better explains long distance performance in swimming. Twenty-two swimmers (19.1±1.5 years, height 173.9±10.0 cm, body mass 71.2±10.2 kg; 76.6±5.3% of 400 m world record) underwent a lactate minimum test to determine lactate minimum speed (LMS) (i.e., aerobic capacity index). Moreover, the swimmers performed a 400 m maximal effort to determine mean speed (S400m), peak oxygen uptake (V.O2PEAK) and total anaerobic contribution (CANA). The CANA was assumed as the sum of alactic and lactic contributions. Physiological parameters of 400 m were determined using the backward extrapolation technique (V.O2PEAK and alactic contributions of CANA) and blood lactate concentration analysis (lactic anaerobic contributions of CANA). The Pearson correlation test and backward multiple regression analysis were used to verify the possible correlations between the physiological indices (predictor factors) and S400m (independent variable) (p < 0.05). Values are presented as mean ± standard deviation. Significant correlations were observed between S400m (1.4±0.1 m·s-1) and LMS (1.3±0.1 m·s-1; r = 0.80), V.O2PEAK (4.5±3.9 L·min-1; r = 0.72) and CANA (4.7±1.5 L·O2; r= 0.44). The best model constructed using multiple regression analysis demonstrated that LMS and V.O2PEAK explained 85% of the 400 m performance variance. When backward multiple regression analysis was performed, CANA lost significance. Thus, the results demonstrated that both aerobic parameters (capacity and power) can be used to predict 400 m swimming performance. PMID:28479663

  15. Trainability of Young Athletes and Overtraining

    PubMed Central

    Matos, Nuno; Winsley, Richard J.

    2007-01-01

    Exercise adaptations to strength, anaerobic and aerobic training have been extensively studied in adults, however, young people appear to respond differently to such exercise stimulus in comparison to adults. In addition, because overtraining in young athletes has received little attention, this important area is also discussed. Resistance training in children can be safe and effective. It has the potential to improve sport performance, enhance body composition and reduce the rate of sport incurred injury. Furthermore, with the appropriate stimulus, prepubertal and adolescent athletes can show significant increments in muscle strength (13 - 30%). Children can improve anaerobic power (3%-10% Mean Power and 4%-20% in Peak Power), although the mechanisms responsible for the improvements in children remain unclear. Children show a ‘reduced’ trainability of peak VO2 in comparison to adults. Nevertheless, their aerobic power is trainable, with improvements reported at approximately 5%. Moreover, improvements in other variables like exercise economy or lactate threshold may occur without significant changes in peak VO2 The limited evidence available indicates that overtraining is occurring in young athletes (30% prevalence), highlighting the importance of further research in to all the possible contributing factors - physiological, psychological and emotional - when investigating overtraining. Key pointsChildren’s strength, anaerobic and aerobic power is trainable, although the improvements may be smaller than seen in adults.Children can demonstrate significant gains in muscle strength with resistance training (13 - 30%).Improvements in mean power (3 - 10%) and peak power (4 - 20%) are reported in children.Aerobic fitness can improve with training in children by approximately 5%.Limited available evidence indicates an occurrence of overtraining in young athletes of around 30%. PMID:24149422

  16. Effect of glycine propionyl-L-carnitine on aerobic and anaerobic exercise performance.

    PubMed

    Smith, Webb A; Fry, Andrew C; Tschume, Lesley C; Bloomer, Richard J

    2008-02-01

    The purpose of this study was to evaluate the effect of glycine propionyl-L-carnitine (GPLC) supplementation and endurance training for 8 wk on aerobic- and anaerobic-exercise performance in healthy men and women (age 18-44 yr). Participants were randomly assigned to 1 of 3 groups: placebo (n=9), 1 g/d GPLC (n=11), or 3 g/d GPLC (n=12), in a double-blind fashion. Muscle carnitine (vastus lateralis), VO(2peak), exercise time to fatigue, anaerobic threshold, anaerobic power, and total work were measured at baseline and after an 8-wk aerobic-training program. There were no statistical differences (p> .05) between or within the 3 groups for any performance-related variable or muscle carnitine concentrations after 8 wk of supplementation and training. These results suggest that up to 3 g/d GPLC for 8 wk in conjunction with aerobic-exercise training is ineffective for increasing muscle carnitine content and has no significant effects on aerobic- or anaerobic-exercise performance.

  17. Antibiotic Production by Anaerobic Bacteria1

    PubMed Central

    Sturgen, Nancy O.; Casida, L. E.

    1962-01-01

    Soils from aerobic and anaerobic sources were investigated for the possible presence of bacteria which produce antibiotics under anaerobic conditions of growth. The screening techniques devised for this study yielded 157 soil bacteria which, during anaerobic growth, produced antibiotic activity against aerobic test bacteria. Studies on choice of media, presence of oxygen, and changes in antibiotic activity during growth indicated that representative strains of these bacteria produced mixtures of antibiotics. The activity was heat labile. PMID:13918037

  18. Cycling Power Outputs Predict Functional Threshold Power And Maximum Oxygen Uptake.

    PubMed

    Denham, Joshua; Scott-Hamilton, John; Hagstrom, Amanda D; Gray, Adrian J

    2017-09-11

    Functional threshold power (FTP) has emerged as a correlate of lactate threshold and is commonly assessed by recreational and professional cyclists for tailored exercise programing. To identify whether results from traditional aerobic and anaerobic cycling tests could predict FTP and V˙ O2max, we analysed the association between estimated FTP, maximum oxygen uptake (V˙ O2max [mlkgmin]) and power outputs obtained from a maximal cycle ergometry cardiopulmonary exercise test (CPET) and a 30-s Wingate test in a heterogeneous cohort of cycle-trained and untrained individuals (N=40, mean±SD; age: 32.6±10.6 y; relative V˙ O2max: 46.8±9.1 mlkgmin). The accuracy and sensitivity of the prediction equations was also assessed in young men (N=11) before and after a 6-wk sprint interval training intervention.Moderate to strong positive correlations were observed between FTP, relative V˙ O2max and power outputs achieved during incremental and 30-s Wingate cycling tests (r=.39-.965, all P<.05). While maximum power achieved during incremental cycle testing (Pmax) and relative V˙ O2max were predictors of FTP (r =.93), age and FTP (Wkg) estimated relative V˙ O2max (r=.80). Our findings confirm that FTP predominantly relies on aerobic metabolism and indicate both prediction models are sensitive enough to detect meaningful exercise-induced changes in FTP and V˙ O2max. Thus, coaches should consider limiting the time and load demands placed on athletes by conducting a maximal cycle ergometry CPET to estimate FTP. Additionally, a 20-min FTP test is a convenient method to assess V˙ O2max and is particularly relevant for exercise professionals without access to expensive CPET equipment.

  19. Effects of acute sleep deprivation and caffeine supplementation on anaerobic performance.

    PubMed

    Moore, Joss; McDonald, Ciaran; McIntyre, Alan; Carmody, Kevin; Donne, Bernard

    2018-01-01

    Athletes involved in team sports may be subject to varying degrees of sleep deprivation either before or after training and competition. Despite the belief among athletes and coaches of the importance of adequate sleep for ensuing performance, the effect of sleep loss on team-sport anaerobic performance remains unclear. There is conflicting evidence in the scientific literature as to the impact of acute sleep deprivation and caffeine supplementation on anaerobic performance indices. The purpose of this study is to investigate the effect of 24 hours of acute sleep deprivation on anaerobic performance and the effect of caffeine supplementation on anaerobic performance in the sleep deprived state. 11 club level games players (n=11, 25±4 yr, 178±7.5 cm, 80.2±10.4 kg, 15.1±5.6% body fat) participated in a repeated measures double-blinded placebo control trial. Following familiarisation, each participant returned for testing on three separate occasions. One of the testing sessions took place following a night of normal sleep and the other two sessions took place following 24 hours of sleep deprivation with supplementation of either placebo or 6 mg.kg- 1 of caffeine. During each testing session participants performed the vertical jump height, 20-m straight sprint, Illinois speed agility test and 5-m shuttle run. No significant differences were detected comparing non sleep deprived and sleep deprived interventions in any of the assessed outcome measures. There were also no significant differences observed in any of the outcome measures when comparing caffeine and placebo data in the sleep deprived state. In this cohort of athletes, a 24-h period of acute sleep deprivation did not have any significant impact on anaerobic performance. Caffeine also did not have any effect of on anaerobic performance in the sleep-deprived state.

  20. Establishing a Practical Treadmill Sprint as an Alternative to the Wingate Anaerobic Test

    ERIC Educational Resources Information Center

    McKie, Greg L.; Islam, Hashim; Townsend, Logan K.; Howe, Greg J.; Hazell, Tom J.

    2018-01-01

    This study examined the validity and reliability of a 30-second running sprint test using two non-motorized treadmills compared to the established Wingate Anaerobic Test. Twenty-four participants completed three sessions in a randomized order on a: (1) manual mode treadmill (Woodway); (2) specialized interval training treadmill (HiTrainer); and…

  1. Use of solid residue from thermal power plant (fly ash) for enhancing sewage sludge anaerobic digestion: Influence of fly ash particle size.

    PubMed

    Montalvo, S; Cahn, I; Borja, R; Huiliñir, C; Guerrero, L

    2017-11-01

    The influence of fly ash particle size on methane production and anaerobic biodegradability was evaluated. Assays with different fly ash particle sizes (0.8-2.36mm) at a concentration of 50mg/L were ran under mesophilic conditions. In anaerobic processes operating with fly ash, greater removal of both volatile total and suspended solids, chemical oxygen demand (total and soluble) was achieved, with an increase of methane production between 28% and 96% compared to the control reactors. The highest increase occurred at ash particles sizes of 1.0-1.4mm. The metal concentrations in the digestates obtained after anaerobic digestion of sewage sludge are far below those considered as limiting for the use of sludge in soils. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Assessing the environmental burdens of anaerobic digestion in comparison to alternative options for managing the biodegradable fraction of municipal solid wastes.

    PubMed

    Haight, M

    2005-01-01

    Biological treatment processes including anaerobic digestion (biogasification) and composting are increasingly being considered by waste management officials and planners as alternatives for managing the mainly organic residues of municipal solid wastes (MSW). The integrated waste management model which is based upon the application of life-cycle analysis was employed to compare the environmental burdens of landfilling, composting and anaerobic digestion of MSW at a mid-sized Canadian community. Energy consumption (or recovery), residue recoveries and emissions to air and water were quantified. Scenario comparisons were analyzed to demonstrate that the environmental burdens associated with anaerobic digestion are reduced in comparison with the alternative options. The major benefit occurs as a result of the electricity produced from burning the biogas and then supplying the 'green power' to the local electrical grid.

  3. Anaerobic Bacteria in Clinical Specimens - Frequent, But a Neglected Lot: A Five Year Experience at a Tertiary Care Hospital.

    PubMed

    Shenoy, Padmaja Ananth; Vishwanath, Shashidhar; Gawda, Ashwini; Shetty, Seema; Anegundi, Renuka; Varma, Muralidhar; Mukhopadhyay, Chiranjay; Chawla, Kiran

    2017-07-01

    Anaerobic bacteria which constitute a significant proportion of the normal microbiota also cause variety of infections involving various anatomic sites. Considering the tedious culture techniques with longer turnaround time, anaerobic cultures are usually neglected by clinicians and microbiologists. To study the frequency of isolation of different anaerobic bacteria from various clinical specimens. A retrospective study to analyse the frequency of isolation of different anaerobic bacteria, was conducted over a period of five years from 2011 to 2015 including various clinical specimens submitted to anaerobic division of Microbiology laboratory. Anaerobic bacteria were isolated and identified following standard bacteriological techniques. Pathogenic anaerobes (n=336) were isolated from 278 (12.48%) of overall 2227 specimens processed with an average yield of 1.2 isolates. Anaerobes were isolated as polymicrobial flora with or without aerobic bacterial pathogens in 159 (57.2%) patients. Anaerobic Gram-negative bacilli (140, 41.7%) were the predominant isolates. B. fragilis group (67, 19.9%) were the most commonly isolated anaerobic pathogens. Anaerobes were predominantly isolated from deep seated abscess (23.9%). Pathogenic anaerobes were isolated from various infection sites. Unless culture and susceptibility tests are performed as a routine, true magnitude of antimicrobial resistance among anaerobic pathogens will not be known. Knowledge of the distribution of these organisms may assist in the selection of appropriate empirical therapy for anaerobic infections.

  4. Effects of multibuffer supplementation on acid-base balance and 2,3-diphosphoglycerate following repetitive anaerobic exercise.

    PubMed

    Kraemer, W J; Gordon, S E; Lynch, J M; Pop, M E; Clark, K L

    1995-12-01

    The purpose of this investigation was to determine the effects of a 3.5-day dietary multibuffer supplement (containing predominantly inorganic phosphate, or Pi, along with bicarbonate and carnosine, i.e., PhosFuel) on repetitive (four trials separated by 2 min rest) Wingate test (WT) performances and whole blood 2,3-diphosphoglycerate (2,3-DPG) concentrations in 10 recreationally trained road cyclists (T) and 10 normally active but untrained (UT) men. A 2-week washout period was utilized between experimental sessions. Venous blood samples were obtained via cannula once before exercise (baseline), immediately post each WT, and 3 min after the final WT (recovery). The data indicate that this supplement does not affect acid-base status with following intense anaerobic exercise and does not improve repetitive WT performance. However, the supplement does enhance post-exercise levels of 2,3-DPG and the 2,3-DPG/Hb ratio in recreationally trained cyclists while improving acute recovery of peak power in these men.

  5. Kinetic modelling of anaerobic hydrolysis of solid wastes, including disintegration processes.

    PubMed

    García-Gen, Santiago; Sousbie, Philippe; Rangaraj, Ganesh; Lema, Juan M; Rodríguez, Jorge; Steyer, Jean-Philippe; Torrijos, Michel

    2015-01-01

    A methodology to estimate disintegration and hydrolysis kinetic parameters of solid wastes and validate an ADM1-based anaerobic co-digestion model is presented. Kinetic parameters of the model were calibrated from batch reactor experiments treating individually fruit and vegetable wastes (among other residues) following a new protocol for batch tests. In addition, decoupled disintegration kinetics for readily and slowly biodegradable fractions of solid wastes was considered. Calibrated parameters from batch assays of individual substrates were used to validate the model for a semi-continuous co-digestion operation treating simultaneously 5 fruit and vegetable wastes. The semi-continuous experiment was carried out in a lab-scale CSTR reactor for 15 weeks at organic loading rate ranging between 2.0 and 4.7 gVS/Ld. The model (built in Matlab/Simulink) fit to a large extent the experimental results in both batch and semi-continuous mode and served as a powerful tool to simulate the digestion or co-digestion of solid wastes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Season-to-Season Variations of Physiological Fitness Within a Squad of Professional Male Soccer Players

    PubMed Central

    Clark, Niall A.; Edwards, Andrew M.; Morton, R. Hugh; Butterly, Ronald J.

    2008-01-01

    The purpose of this study was to examine season-to-season variations in physiological fitness parameters among a 1st team squad of professional adult male soccer players for the confirmatory purposes of identifying normative responses (immediately prior to pre-season training (PPS), mid-season (MID), and end-of-season (EOS)). Test-retest data were collected from a student population on the primary dependent variables of anaerobic threshold (AT) and maximal aerobic power (VO2 max) to define meaningful measurement change in excess of test-retest technical error between test-to-test performances. Participants from a pool of 42 professional soccer players were tested over a set sequence of tests during the 3-year period: 1) basic anthropometry, 2) countermovement jump (CMJ) tests 3) a combined AT and VO2 max test. Over the 3-year period there were no test-to-test changes in mean VO2 max performance exceeding pre-defined limits of test agreement (mean of eight measures: 61.6 ± 0.6 ml·kg-1·min-1). In contrast, VO2 at AT was significantly higher at the MID test occasion in seasons 2 (+4.8%; p = 0.04, p < 0.05) and 3 (+6.8%; p = 0.03, p < 0.05). The CMJ tests showed a test-to-test improvement of 6.3% (best of 3 jumps) (p = 0.03, p < 0.05) and 10.3% (20-s sustained jumping test) (p = 0.007, p < 0.01) between PPS2 and MID2 and thereafter remained stable. Anthropometrics were unaffected. In summary, despite some personnel changes in the elite cohort between test-to-test occasions, VO2 max values did not vary significantly over the study which supports previous short-term observations suggesting a general ‘elite’ threshold of 60 ml·kg-1 min. Interestingly, AT significantly varied where VO2 max was stable and these variations also coincided with on- and off-seasons suggesting that AT is a better indication of acute training state than VO2 max. Key points Maximal aerobic power remains fairly stable across inter- and intra-season measurements. Anaerobic threshold appears more sensitive of training state confirming our earlier observations. The professional players tended to attain optimal performances at the mid-season interval over the 3 seasons, presumably prior to the development of accumulative fatigue. PMID:24150149

  7. Kinetic study of the anaerobic biodegradation of alkyl polyglucosides and the influence of their structural parameters.

    PubMed

    Ríos, Francisco; Fernández-Arteaga, Alejandro; Lechuga, Manuela; Jurado, Encarnación; Fernández-Serrano, Mercedes

    2016-05-01

    This paper reports a study of the anaerobic biodegradation of non-ionic surfactants alkyl polyglucosides applying the method by measurement of the biogas production in digested sludge. Three alkyl polyglucosides with different length alkyl chain and degree of polymerization of the glucose units were tested. The influence of their structural parameters was evaluated, and the characteristics parameters of the anaerobic biodegradation were determined. Results show that alkyl polyglucosides, at the standard initial concentration of 100 mgC L(-1), are not completely biodegradable in anaerobic conditions because they inhibit the biogas production. The alkyl polyglucoside having the shortest alkyl chain showed the fastest biodegradability and reached the higher percentage of final mineralization. The anaerobic process was well adjusted to a pseudo first-order equation using the carbon produced as gas during the test; also, kinetics parameters and a global rate constant for all the involved metabolic process were determined. This modeling is helpful to evaluate the biodegradation or the persistence of alkyl polyglucosides under anaerobic conditions in the environment and in the wastewater treatment.

  8. Antimicrobial Susceptibility of Enteric Gram Negative Facultative Anaerobe Bacilli in Aerobic versus Anaerobic Conditions

    PubMed Central

    Amachawadi, Raghavendra G.; Renter, David G.; Volkova, Victoriya V.

    2016-01-01

    Antimicrobial treatments result in the host’s enteric bacteria being exposed to the antimicrobials. Pharmacodynamic models can describe how this exposure affects the enteric bacteria and their antimicrobial resistance. The models utilize measurements of bacterial antimicrobial susceptibility traditionally obtained in vitro in aerobic conditions. However, in vivo enteric bacteria are exposed to antimicrobials in anaerobic conditions of the lower intestine. Some of enteric bacteria of food animals are potential foodborne pathogens, e.g., Gram-negative bacilli Escherichia coli and Salmonella enterica. These are facultative anaerobes; their physiology and growth rates change in anaerobic conditions. We hypothesized that their antimicrobial susceptibility also changes, and evaluated differences in the susceptibility in aerobic vs. anaerobic conditions of generic E. coli and Salmonella enterica of diverse serovars isolated from cattle feces. Susceptibility of an isolate was evaluated as its minimum inhibitory concentration (MIC) measured by E-Test® following 24 hours of adaptation to the conditions on Mueller-Hinton agar, and on a more complex tryptic soy agar with 5% sheep blood (BAP) media. We considered all major antimicrobial drug classes used in the U.S. to treat cattle: β-lactams (specifically, ampicillin and ceftriaxone E-Test®), aminoglycosides (gentamicin and kanamycin), fluoroquinolones (enrofloxacin), classical macrolides (erythromycin), azalides (azithromycin), sulfanomides (sulfamethoxazole/trimethoprim), and tetracyclines (tetracycline). Statistical analyses were conducted for the isolates (n≥30) interpreted as susceptible to the antimicrobials based on the clinical breakpoint interpretation for human infection. Bacterial susceptibility to every antimicrobial tested was statistically significantly different in anaerobic vs. aerobic conditions on both media, except for no difference in susceptibility to ceftriaxone on BAP agar. A satellite experiment suggested that during first days in anaerobic conditions the susceptibility changes with time. The results demonstrate that assessing effects of antimicrobial treatments on resistance in the host’s enteric bacteria that are Gram negative facultative Anaerobe Bacilli requires data on the bacterial antimicrobial susceptibility in the conditions resembling those in the intestine. PMID:27191612

  9. Feasibility Study of Anaerobic Digestion of Food Waste in St. Bernard, Louisiana. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moriarty, K.

    The U.S. Environmental Protection Agency (EPA) developed the RE-Powering America's Land initiative to re-use contaminated sites for renewable energy generation when aligned with the community's vision for the site. The former Kaiser Aluminum Landfill in St. Bernard Parish, Louisiana, was selected for a feasibility study under the program. Preliminary work focused on selecting a biomass feedstock. Discussions with area experts, universities, and the project team identified food wastes as the feedstock and anaerobic digestion (AD) as the technology.

  10. Evaluation test on a landfill gas-fired internal-combustion-engine system at the City of Glendale No. 1 Scholl Canyon Power Plant. Air pollution test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-07-01

    A cooperative test program was conducted from January 28 through January 31, 1986, by Air Resources Board (ARB) and South Coast Air Quality Management District (SCAQMD) staff to evaluate the gaseous constituents from untreated landfill gas used to fuel an internal combustion engine (ICE) and the emissions from that ICE located at the City of Glendale Scholl Canyon Power Plant. The ICE was fueled with gases generated by the anaerobic decomposition of buried refuse at the No. 1 Scholl Canyon Landfill operated by the City of Glendale, Public Service Department. The test was conducted as part of an ongoing programmore » by the SCAQMD to allow assessment of the inlet fuel gas (landfill gas) and exhaust gas characteristics from such devices as ICEs, gas turbines, and flares. Emissions of criteria pollutants as determined from test data are reported. Mass flow rates and destruction and removal efficiencies (DRE's) of non-criteria pollutants compounds determined from SCAQMD bag sample test data and mass flow rates and DRE's for chlorinated and aromatic compounds determined from data from ARB resin samples are presented.« less

  11. Accelerated anaerobic hydrolysis rates under a combination of intermittent aeration and anaerobic conditions.

    PubMed

    Jensen, T R; Lastra Milone, T; Petersen, G; Andersen, H R

    2017-04-01

    Anaerobic hydrolysis in activated return sludge was investigated in laboratory scale experiments to find if intermittent aeration would accelerate anaerobic hydrolysis rates compared to anaerobic hydrolysis rates under strict anaerobic conditions. The intermittent reactors were set up in a 240 h experiment with intermittent aeration (3 h:3 h) in a period of 24 h followed by a subsequent anaerobic period of 24 h in a cycle of 48 h which was repeated five times during the experiment. The anaerobic reactors were kept under strict anaerobic conditions in the same period (240 h). Two methods for calculating hydrolysis rates based on soluble chemical oxygen demand were compared. Two-way analysis of variance with the Bonferroni post-test was performed in order to register any significant difference between reactors with intermittent aeration and strictly anaerobic conditions respectively. The experiment demonstrated a statistically significant difference in favor of the reactors with intermittent aeration showing a tendency towards accelerated anaerobic hydrolysis rates due to application of intermittent aeration. The conclusion of the work is thus that intermittent aeration applied in the activated return sludge process can improve the treatment capacity further in full scale applications.

  12. A simple method for measurement of maximal downstroke power on friction-loaded cycle ergometer.

    PubMed

    Morin, Jean-Benoît; Belli, Alain

    2004-01-01

    The aim of this study was to propose and validate a post-hoc correction method to obtain maximal power values taking into account inertia of the flywheel during sprints on friction-loaded cycle ergometers. This correction method was obtained from a basic postulate of linear deceleration-time evolution during the initial phase (until maximal power) of a sprint and included simple parameters as flywheel inertia, maximal velocity, time to reach maximal velocity and friction force. The validity of this model was tested by comparing measured and calculated maximal power values for 19 sprint bouts performed by five subjects against 0.6-1 N kg(-1) friction loads. Non-significant differences between measured and calculated maximal power (1151+/-169 vs. 1148+/-170 W) and a mean error index of 1.31+/-1.20% (ranging from 0.09% to 4.20%) showed the validity of this method. Furthermore, the differences between measured maximal power and power neglecting inertia (20.4+/-7.6%, ranging from 9.5% to 33.2%) emphasized the usefulness of power correcting in studies about anaerobic power which do not include inertia, and also the interest of this simple post-hoc method.

  13. Treating refinery wastewaters in microbial fuel cells using separator electrode assembly or spaced electrode configurations.

    PubMed

    Zhang, Fang; Ahn, Yongtae; Logan, Bruce E

    2014-01-01

    The effectiveness of refinery wastewater (RW) treatment using air-cathode, microbial fuel cells (MFCs) was examined relative to previous tests based on completely anaerobic microbial electrolysis cells (MECs). MFCs were configured with separator electrode assembly (SEA) or spaced electrode (SPA) configurations to measure power production and relative impacts of oxygen crossover on organics removal. The SEA configuration produced a higher maximum power density (280±6 mW/m(2); 16.3±0.4 W/m(3)) than the SPA arrangement (255±2 mW/m(2)) due to lower internal resistance. Power production in both configurations was lower than that obtained with the domestic wastewater (positive control) due to less favorable (more positive) anode potentials, indicating poorer biodegradability of the RW. MFCs with RW achieved up to 84% total COD removal, 73% soluble COD removal and 92% HBOD removal. These removals were higher than those previously obtained in mini-MEC tests, as oxygen crossover from the cathode enhanced degradation in MFCs compared to MECs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Effects of acute hypoxia on the determination of anaerobic threshold using the heart rate-work rate relationships during incremental exercise tests.

    PubMed

    Ozcelik, O; Kelestimur, H

    2004-01-01

    Anaerobic threshold which describes the onset of systematic increase in blood lactate concentration is a widely used concept in clinical and sports medicine. A deflection point between heart rate-work rate has been introduced to determine the anaerobic threshold non-invasively. However, some researchers have consistently reported a heart rate deflection at higher work rates, while others have not. The present study was designed to investigate whether the heart rate deflection point accurately predicts the anaerobic threshold under the condition of acute hypoxia. Eight untrained males performed two incremental exercise tests using an electromagnetically braked cycle ergometer: one breathing room air and one breathing 12 % O2. The anaerobic threshold was estimated using the V-slope method and determined from the increase in blood lactate and the decrease in standard bicarbonate concentration. This threshold was also estimated by in the heart rate-work rate relationship. Not all subjects exhibited a heart rate deflection. Only two subjects in the control and four subjects in the hypoxia groups showed a heart rate deflection. Additionally, the heart rate deflection point overestimated the anaerobic threshold. In conclusion, the heart rate deflection point was not an accurate predictor of anaerobic threshold and acute hypoxia did not systematically affect the heart rate-work rate relationships.

  15. Effect of task familiarisation on distribution of energy during a 2000 m cycling time trial.

    PubMed

    Corbett, J; Barwood, M J; Parkhouse, K

    2009-10-01

    To investigate the effect of task familiarisation on the spontaneous pattern of energy expenditure during a series of 2000 m cycling time trials (TTs). Nine trained males completed three 2000 m TTs on a Velotron cycling ergometer. To examine pacing strategy, the data were assigned to 250 m "bins," with the pattern of aerobic and anaerobic energy expenditure calculated from total work accomplished and gas-exchange data. There were no significant differences between trials in performance times (191.4 (SD 4.3), 189.4 (4.6), 190.1 (5.6) s), total aerobic (58.3 (2.7), 58.4 (3.1), 58.0 (3.4) kJ) and total anaerobic energy expenditure (16.4 (3.3), 17.3 (2.8), 16.5 (3.1) kJ). Pacing strategy in the second and third TT differed from the first TT in that a lower power output was adopted during the first 500 m, enabling a higher power output during the final 750 m of the TT. This adjustment in the pattern of energy expenditure was mediated by an alteration in the pattern of anaerobic energy expenditure, which paralleled changes in total energy expenditure. Furthermore, participants retained an anaerobic energy "reserve" enabling an end-spurt during the second and third trials. Small modifications to the pacing strategy are made following a single bout of exercise, primarily by altering the rate of anaerobic energy expenditure. This may have served to prevent critical metabolic disturbances. The alteration in pacing strategy following the first exercise bout is compatible with a complex intelligent regulatory system.

  16. Anaerobic Bacteria in Clinical Specimens – Frequent, But a Neglected Lot: A Five Year Experience at a Tertiary Care Hospital

    PubMed Central

    Shenoy, Padmaja Ananth; Gawda, Ashwini; Shetty, Seema; Anegundi, Renuka; Varma, Muralidhar; Mukhopadhyay, Chiranjay; Chawla, Kiran

    2017-01-01

    Introduction Anaerobic bacteria which constitute a significant proportion of the normal microbiota also cause variety of infections involving various anatomic sites. Considering the tedious culture techniques with longer turnaround time, anaerobic cultures are usually neglected by clinicians and microbiologists. Aim To study the frequency of isolation of different anaerobic bacteria from various clinical specimens. Materials and Methods A retrospective study to analyse the frequency of isolation of different anaerobic bacteria, was conducted over a period of five years from 2011 to 2015 including various clinical specimens submitted to anaerobic division of Microbiology laboratory. Anaerobic bacteria were isolated and identified following standard bacteriological techniques. Results Pathogenic anaerobes (n=336) were isolated from 278 (12.48%) of overall 2227 specimens processed with an average yield of 1.2 isolates. Anaerobes were isolated as polymicrobial flora with or without aerobic bacterial pathogens in 159 (57.2%) patients. Anaerobic Gram-negative bacilli (140, 41.7%) were the predominant isolates. B. fragilis group (67, 19.9%) were the most commonly isolated anaerobic pathogens. Anaerobes were predominantly isolated from deep seated abscess (23.9%). Conclusion Pathogenic anaerobes were isolated from various infection sites. Unless culture and susceptibility tests are performed as a routine, true magnitude of antimicrobial resistance among anaerobic pathogens will not be known. Knowledge of the distribution of these organisms may assist in the selection of appropriate empirical therapy for anaerobic infections. PMID:28892897

  17. Maximal aerobic and anaerobic power generation in large crocodiles versus mammals: implications for dinosaur gigantothermy.

    PubMed

    Seymour, Roger S

    2013-01-01

    Inertial homeothermy, the maintenance of a relatively constant body temperature that occurs simply because of large size, is often applied to large dinosaurs. Moreover, biophysical modelling and actual measurements show that large crocodiles can behaviourally achieve body temperatures above 30°C. Therefore it is possible that some dinosaurs could achieve high and stable body temperatures without the high energy cost of typical endotherms. However it is not known whether an ectothermic dinosaur could produce the equivalent amount of muscular power as an endothermic one. To address this question, this study analyses maximal power output from measured aerobic and anaerobic metabolism in burst exercising estuarine crocodiles, Crocodylusporosus, weighing up to 200 kg. These results are compared with similar data from endothermic mammals. A 1 kg crocodile at 30°C produces about 16 watts from aerobic and anaerobic energy sources during the first 10% of exhaustive activity, which is 57% of that expected for a similarly sized mammal. A 200 kg crocodile produces about 400 watts, or only 14% of that for a mammal. Phosphocreatine is a minor energy source, used only in the first seconds of exercise and of similar concentrations in reptiles and mammals. Ectothermic crocodiles lack not only the absolute power for exercise, but also the endurance, that are evident in endothermic mammals. Despite the ability to achieve high and fairly constant body temperatures, therefore, large, ectothermic, crocodile-like dinosaurs would have been competitively inferior to endothermic, mammal-like dinosaurs with high aerobic power. Endothermy in dinosaurs is likely to explain their dominance over mammals in terrestrial ecosystems throughout the Mesozoic.

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: UTC FUEL CELLS' PC25C POWER PLANT - GAS PROCESSING UNIT PERFORMANCE FOR ANAEROBIC DIGESTER GAS

    EPA Science Inventory

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, a combined heat and power system based on the UTC Fuel Cell's PC25C Fuel Cell Power Plant was evaluated. The...

  19. Dynamics and genetic diversification of Escherichia coli during experimental adaptation to an anaerobic environment

    PubMed Central

    Finn, Thomas J.; Shewaramani, Sonal; Leahy, Sinead C.; Janssen, Peter H.

    2017-01-01

    Background Many bacteria are facultative anaerobes, and can proliferate in both anoxic and oxic environments. Under anaerobic conditions, fermentation is the primary means of energy generation in contrast to respiration. Furthermore, the rates and spectra of spontaneous mutations that arise during anaerobic growth differ to those under aerobic growth. A long-term selection experiment was undertaken to investigate the genetic changes that underpin how the facultative anaerobe, Escherichia coli, adapts to anaerobic environments. Methods Twenty-one populations of E. coli REL4536, an aerobically evolved 10,000th generation descendent of the E. coli B strain, REL606, were established from a clonal ancestral culture. These were serially sub-cultured for 2,000 generations in a defined minimal glucose medium in strict aerobic and strict anaerobic environments, as well as in a treatment that fluctuated between the two environments. The competitive fitness of the evolving lineages was assessed at approximately 0, 1,000 and 2,000 generations, in both the environment of selection and the alternative environment. Whole genome re-sequencing was performed on random colonies from all lineages after 2,000-generations. Mutations were identified relative to the ancestral genome, and based on the extent of parallelism, traits that were likely to have contributed towards adaptation were inferred. Results There were increases in fitness relative to the ancestor among anaerobically evolved lineages when tested in the anaerobic environment, but no increases were found in the aerobic environment. For lineages that had evolved under the fluctuating regime, relative fitness increased significantly in the anaerobic environment, but did not increase in the aerobic environment. The aerobically-evolved lineages did not increase in fitness when tested in either the aerobic or anaerobic environments. The strictly anaerobic lineages adapted more rapidly to the anaerobic environment than did the fluctuating lineages. Two main strategies appeared to predominate during adaptation to the anaerobic environment: modification of energy generation pathways, and inactivation of non-essential functions. Fermentation pathways appeared to alter through selection for mutations in genes such as nadR, adhE, dcuS/R, and pflB. Mutations were frequently identified in genes for presumably dispensable functions such as toxin-antitoxin systems, prophages, virulence and amino acid transport. Adaptation of the fluctuating lineages to the anaerobic environments involved mutations affecting traits similar to those observed in the anaerobically evolved lineages. Discussion There appeared to be strong selective pressure for activities that conferred cell yield advantages during anaerobic growth, which include restoring activities that had previously been inactivated under long-term continuous aerobic evolution of the ancestor. PMID:28480139

  20. Step length and individual anaerobic threshold assessment in swimming.

    PubMed

    Fernandes, R J; Sousa, M; Machado, L; Vilas-Boas, J P

    2011-12-01

    Anaerobic threshold is widely used for diagnosis of swimming aerobic endurance but the precise incremental protocols step duration for its assessment is controversial. A physiological and biomechanical comparison between intermittent incremental protocols with different step lengths and a maximal lactate steady state (MLSS) test was conducted. 17 swimmers performed 7×200, 300 and 400 m (30 s and 24 h rest between steps and protocols) in front crawl until exhaustion and an MLSS test. The blood lactate concentration values ([La-]) at individual anaerobic threshold were 2.1±0.1, 2.2±0.2 and 1.8±0.1 mmol.l - 1 in the 200, 300 and 400 m protocols (with significant differences between 300 and 400 m tests), and 2.9±1.2 mmol.l - 1 at MLSS (higher than the incremental protocols); all these values are much lower than the traditional 4 mmol.l - 1 value. The velocities at individual anaerobic threshold obtained in incremental protocols were similar (and highly related) to the MLSS, being considerably lower than the velocity at 4 mmol.l - 1. Stroke rate increased and stroke length decreased throughout the different incremental protocols. It was concluded that it is valid to use intermittent incremental protocols of 200 and 300 m lengths to assess the swimming velocity corresponding to individual anaerobic threshold, the progressive protocols tend to underestimate the [La-] at anaerobic threshold assessed by the MLSS test, and swimmers increase velocity through stroke rate increases. © Georg Thieme Verlag KG Stuttgart · New York.

  1. In-vitro activity of solithromycin against anaerobic bacteria from the normal intestinal microbiota.

    PubMed

    Weintraub, Andrej; Rashid, Mamun-Ur; Nord, Carl Erik

    2016-12-01

    Solithromycin is a novel fluoroketolide with high activity against bacteria associated with community-acquired respiratory tract infections as well as gonorrhea. However, data on the activity of solithromycin against anaerobic bacteria from the normal intestinal microbiota are scarce. In this study, 1024 Gram-positive and Gram-negative anaerobic isolates from the normal intestinal microbiota were analyzed for in-vitro susceptibility against solithromycin and compared to azithromycin, amoxicillin/clavulanic acid, ceftriaxone, metronidazole and levofloxacin by determining the minimum inhibitory concentration (MIC). Solithromycin was active against Bifidobacteria (MIC 50 , 0.008 mg/L) and Lactobacilli (MIC 50 , 0.008 mg/L). The MIC 50 for Clostridia, Bacteroides, Prevotella and Veillonella were 0.5, 0.5, 0.125 and 0.016 mg/L, respectively. Gram-positive anaerobes were more susceptible to solithromycin as compared to the other antimicrobials tested. The activity of solithromycin against Gram-negative anaerobes was equal or higher as compared to other tested agents. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Multicenter Study of Antimicrobial Susceptibility of Anaerobic Bacteria in Korea in 2012

    PubMed Central

    Lee, Yangsoon; Park, Yeon-Joon; Kim, Mi-Na; Uh, Young; Kim, Myung Sook

    2015-01-01

    Background Periodic monitoring of regional or institutional resistance trends of clinically important anaerobic bacteria is recommended, because the resistance of anaerobic pathogens to antimicrobial drugs and inappropriate therapy are associated with poor clinical outcomes. There has been no multicenter study of clinical anaerobic isolates in Korea. We aimed to determine the antimicrobial resistance patterns of clinically important anaerobes at multiple centers in Korea. Methods A total of 268 non-duplicated clinical isolates of anaerobic bacteria were collected from four large medical centers in Korea in 2012. Antimicrobial susceptibility was tested by the agar dilution method according to the CLSI guidelines. The following antimicrobials were tested: piperacillin, piperacillin-tazobactam, cefoxitin, cefotetan, imipenem, meropenem, clindamycin, moxifloxacin, chloramphenicol, metronidazole, and tigecycline. Results Organisms of the Bacteroides fragilis group were highly susceptible to piperacillin-tazobactam, imipenem, and meropenem, as their resistance rates to these three antimicrobials were lower than 6%. For B. fragilis group isolates and anaerobic gram-positive cocci, the resistance rates to moxifloxacin were 12-25% and 11-13%, respectively. Among B. fragilis group organisms, the resistance rates to tigecycline were 16-17%. Two isolates of Finegoldia magna were non-susceptible to chloramphenicol (minimum inhibitory concentrations of 16-32 mg/L). Resistance patterns were different among the different hospitals. Conclusions Piperacillin-tazobactam, cefoxitin, and carbapemems are highly active β-lactam agents against most of the anaerobes. The resistance rates to moxifloxacin and tigecycline are slightly higher than those in the previous study. PMID:26206683

  3. [Anaerobic digestion of lignocellulosic biomass with animal digestion mechanisms].

    PubMed

    Wu, Hao; Zhang, Pan-Yue; Guo, Jian-Bin; Wu, Yong-Jie

    2013-02-01

    Lignocellulosic material is the most abundant renewable resource in the earth. Herbivores and wood-eating insects are highly effective in the digestion of plant cellulose, while anaerobic digestion process simulating animal alimentary tract still remains inefficient. The digestion mechanisms of herbivores and wood-eating insects and the development of anaerobic digestion processes of lignocellulose were reviewed for better understanding of animal digestion mechanisms and their application in design and operation of the anaerobic digestion reactor. Highly effective digestion of lignocellulosic materials in animal digestive system results from the synergistic effect of various digestive enzymes and a series of physical and biochemical reactions. Microbial fermentation system is strongly supported by powerful pretreatment, such as rumination of ruminants, cellulase catalysis and alkali treatment in digestive tract of wood-eating insects. Oxygen concentration gradient along the digestive tract may stimulate the hydrolytic activity of some microorganisms. In addition, the excellent arrangement of solid retention time, digesta flow and end product discharge enhance the animal digestion of wood cellulose. Although anaerobic digestion processes inoculated with rumen microorganisms based rumen digestion mechanisms were developed to treat lignocellulose, the fermentation was more greatly limited by the environmental conditions in the anaerobic digestion reactors than that in rumen or hindgut. Therefore, the anaerobic digestion processes simulating animal digestion mechanisms can effectively enhance the degradation of wood cellulose and other organic solid wastes.

  4. The anaerobic potentially mineralizable nitrogen test as a tool for nitrogen management in the Midwest

    USDA-ARS?s Scientific Manuscript database

    The anaerobic potentially mineralizable nitrogen (PMNan) test is a tool that can improve estimations of mineralizable nitrogen (N) and enhance nitrogen use efficiency. This tool may also help improve predictions of N uptake, grain yield, and the economic optimum nitrogen rate (EONR) of corn (Zea ma...

  5. Anaerobic biodegradability and methanogenic toxicity of key constituents in copper chemical mechanical planarization effluents of the semiconductor industry.

    PubMed

    Hollingsworth, Jeremy; Sierra-Alvarez, Reyes; Zhou, Michael; Ogden, Kimberly L; Field, Jim A

    2005-06-01

    Copper chemical mechanical planarization (CMP) effluents can account for 30-40% of the water discharge in semiconductor manufacturing. CMP effluents contain high concentrations of soluble copper and a complex mixture of organic constituents. The aim of this study is to perform a preliminary assessment of the treatability of CMP effluents in anaerobic sulfidogenic bioreactors inoculated with anaerobic granular sludge by testing individual compounds expected in the CMP effluents. Of all the compounds tested (copper (II), benzotriazoles, polyethylene glycol (M(n) 300), polyethylene glycol (M(n) 860) monooleate, perfluoro-1-octane sulfonate, citric acid, oxalic acid and isopropanol) only copper was found to be inhibitory to methanogenic activity at the concentrations tested. Most of the organic compounds tested were biodegradable with the exception of perfluoro-1-octane sulfonate and benzotriazoles under sulfate reducing conditions and with the exception of the same compounds as well as Triton X-100 under methanogenic conditions. The susceptibility of key components in CMP effluents to anaerobic biodegradation combined with their low microbial inhibition suggest that CMP effluents should be amenable to biological treatment in sulfate reducing bioreactors.

  6. Controversies in the physiological basis of the 'anaerobic threshold' and their implications for clinical cardiopulmonary exercise testing.

    PubMed

    Hopker, J G; Jobson, S A; Pandit, J J

    2011-02-01

    This article reviews the notion of the 'anaerobic threshold' in the context of cardiopulmonary exercise testing. Primarily, this is a review of the proposed mechanisms underlying the ventilatory and lactate response to incremental exercise, which is important to the clinical interpretation of an exercise test. Since such tests are often conducted for risk stratification before major surgery, a failure to locate or justify the existence of an anaerobic threshold will have some implications for clinical practice. We also consider alternative endpoints within the exercise response that might be better used to indicate a patient's capacity to cope with the metabolic demands encountered both during and following major surgery. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  7. [Identification of anaerobic gram-negative bacilli isolated from various clinical specimens and determination of antibiotic resistance profiles with E-test methods].

    PubMed

    Demir, Cengiz; Keşli, Recep

    2018-01-01

    The aim of this study was to identify gram-negative anaerobic bacilli isolated from various clinical specimens that were obtained from patients with suspected anaerobic infections and to determine the antibiotic resistance profiles by using the antibiotic concentration gradient method. The study was performed in Afyon Kocatepe University Ahmet Necdet Sezer Research and Practice Hospital, Medical Microbiology Laboratory between 1 November 2014 and 30 October 2015. Two hundred and seventyeight clinical specimens accepted for anaerobic culture were enrolled in the study. All the samples were cultivated anaerobically by using Schaedler agar with 5% defibrinated sheep blood and Schaedler broth. The isolated anaerobic gram-negative bacilli were identified by using both the conventional methods and automated identification system (VITEK 2, bioMerieux, France). Antibiotic susceptibility tests were performed with antibiotic concentration gradient method (E-test, bioMerieux, France); against penicillin G, clindamycin, cefoxitin, metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem for each isolate. Of the 28 isolated anaerobic gram-negative bacilli; 14 were identified as Bacteroides fragilis group, 9 were Prevotella spp., and 5 were Fusobacterium spp. The highest resistance rate was found against penicillin (78.5%) and resistance rates against clindamycin and cefoxitin were found as 17.8% and 21.4%, respectively. No resistance was found against metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem. As a result, isolation and identification of anaerobic bacteria are difficult, time-consuming and more expensive when compared with the cost of aerobic culture. The rate of anaerobic bacteria isolation may be increased by obtaining the appropriate clinical specimen and appropriate transportation of these specimens. We believe that the data obtained from the study in our center may offer benefits for the follow up and treatment of infections caused by anaerobic bacteria and may contribute to the current literature. Because of high resistance rate detected against penicillin, this antibiotic should not be used as a first choice in empirical treatment. Cefoxitin may be used in empirical antimicrobial treatment of anaerobic gram-negatives; but the rate of antibiotic resistance should be detected for more useful and proper treatment. The prior selection of the most effective antibiotic, may contribute to decrease the rate of high resistance. In our study, no resistance was observed against carbapenem group antibiotics and metronidazole; so these antibiotics should be reserved as treatment options in the future for infections caused by resistant gram-negative anaerobic bacteria.

  8. Effects of Exercise Induced Dehydration and Glycerol Rehydration on Anaerobic Power in Male Collegiate Wrestlers.

    PubMed

    McKenna, Zachary J; Gillum, Trevor L

    2017-11-01

    McKenna, ZJ and Gillum, TL. Effects of exercise induced dehydration and glycerol rehydration on anaerobic power in male collegiate wrestlers. J Strength Cond Res 31(11): 2965-2968, 2017-Wrestlers attempting to reach a specific weight class often use rapid weight loss (RWL). Rapid weight loss is associated with high levels of dehydration, which may hinder athletic performance. Thus, there is a need for wrestlers to optimize rehydration after achieving a specific weight. We sought to observe the effects of RWL on anaerobic power and the impact of glycerol on rehydration and power in male collegiate wrestlers (n = 7, 19.75 ± 1.67 years, 76.8 ± 4.32 kg, 11.6 ± 4.32% body fat, 59.9 ± 6.42 ml·kg·min). Subjects were assessed for body mass (BM), hydration, and mean power output (Wmean) before exercise (pre), immediately after exercise (3% dehydrated), and 60 minutes after exercise (rehydrated). Participants ran at 70% of V[Combining Dot Above]O2max in a heated room (30° C) until 3% BM loss (BML). Subjects rehydrated drinking either 26 ml·kg of water (control) or a 3% glycerol (treatment) solution containing 26 ml·kg of water and 1 g·kg of glycerol. Participants lost 3.00 ± 0.31% (control) and 2.89 ± 0.26% (treatment) of their BM from the pre- to dehydrated conditions. Wmean (control: 659.29 ± 79.12, 651.43 ± 70.71, 659.71 ± 82.78; treatment: 647.71 ± 110.64, 644.57 ± 118.15, 638.14 ± 100.71) did not differ across time (p = 0.87) nor condition (p = 0.80). In addition, glycerol had no significant impact on acute hydration (control: urine-specific gravity [SG] = 1.019 ± 0.010; treatment: SG = 1.017 ± 0.017). These data show that 3% BML did not impair anaerobic performance, and furthermore that glycerol proved ineffective for rehydration in a match like scenario for the competing wrestler.

  9. Anaerobic bacteria growth in the presence of cathelicidin LL-37 and selected ceragenins delivered as magnetic nanoparticles cargo.

    PubMed

    Durnaś, Bonita; Piktel, Ewelina; Wątek, Marzena; Wollny, Tomasz; Góźdź, Stanisław; Smok-Kalwat, Jolanta; Niemirowicz, Katarzyna; Savage, Paul B; Bucki, Robert

    2017-07-26

    Cationic antibacterial peptides (CAPs) and synthetic molecules mimicking the amphiphilic structure of CAPs, such as ceragenins, are promising compounds for the development of new antimicrobials. We tested the in vitro activity of ceragenins CSA-13 and CSA-131 against several anaerobic bacteria including Bacteroides spp. and Clostridium difficile. We compared results to the activity of cathelicidin LL-37, metronidazole and nanosystems developed by attachment of CSA-13 and CSA-131 to magnetic nanoparticles (MNPs). The antibacterial effect was tested using killing assay and modified CLSI broth microdilution assay. Ceragenins CSA-13 and CSA-131 displayed stronger bactericidal activity than LL-37 or metronidazole against all of the tested bacterial strains. Additionally CSA-131 revealed an enhanced ability to prevent the formation of Bacteroides fragilis and Propionibacterium acnes biofilms. These data confirmed that ceragenins display antimicrobial activity against a broad range of microorganisms including anaerobic bacteria and deserve further investigations as compounds serving to develop new treatment against anaerobic and mixed infections.

  10. Determination of the anaerobic threshold in the pre-operative assessment clinic: inter-observer measurement error.

    PubMed

    Sinclair, R C F; Danjoux, G R; Goodridge, V; Batterham, A M

    2009-11-01

    The variability between observers in the interpretation of cardiopulmonary exercise tests may impact upon clinical decision making and affect the risk stratification and peri-operative management of a patient. The purpose of this study was to quantify the inter-reader variability in the determination of the anaerobic threshold (V-slope method). A series of 21 cardiopulmonary exercise tests from patients attending a surgical pre-operative assessment clinic were read independently by nine experienced clinicians regularly involved in clinical decision making. The grand mean for the anaerobic threshold was 10.5 ml O(2).kg body mass(-1).min(-1). The technical error of measurement was 8.1% (circa 0.9 ml.kg(-1).min(-1); 90% confidence interval, 7.4-8.9%). The mean absolute difference between readers was 4.5% with a typical random error of 6.5% (6.0-7.2%). We conclude that the inter-observer variability for experienced clinicians determining the anaerobic threshold from cardiopulmonary exercise tests is acceptable.

  11. Evaluation of the effects of low energetic microwave irradiation on anaerobic digestion.

    PubMed

    Bastiaens, Bert; Van den Broeck, Rob; Appels, Lise; Dewil, Raf

    2017-11-01

    The present study investigates the effects of microwave irradiation on the performance of anaerobic digestion processes. A first set of experiments is performed to distinguish the upper limit of the applied energy levels. Secondly, the effects of these treatments on the performance of the digestion process are evaluated in 3 experimental setups: (i) monitoring the acetic acid degradation, (ii) performing a biological methane potential (BMP) assay and (iii) conducting a specific methanogenic activity (SMA) test. The solubilisation experiment reveals a limited degree of disintegration of anaerobic biomass up to a microwave treatment of 10000 kJ/kg TS. Above this threshold value the soluble COD level started to rise, with up to 350% at 30000 kJ/kg TS regardless of the microwave output power. Because solubilisation of the biomass increases the easily degradable content, this would lead to false observations regarding increased activity. Therefore, solubilisation is minimized by limiting the microwave treatment to a maximum of 6000 kJ/kg TS during the second part of the experiments. Monitoring the degradation of acetic acid after a low intensity microwave treatment, reveals that microwave irradiation shortens the lag phase, e.g., from 21 to 3 h after a microwave treatment of 1000 kJ/kg TS at 100 W. However most treatments also result in a decrease of the maximum degradation and of the degradation rate of acetic acid. BMP assays are performed to evaluate the activity and performance of the entire anaerobic community. Every treatment results in a decreased biogas production potential and decreased biogas production rate. Moreover, each treatment induced an increase of the lag phase. The SMA experiments show no influence of the microwave irradiation in terms of biogas or methane production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Effects of hydraulic resistance circuit training on physical fitness components of potential relevance to +Gz tolerance.

    PubMed

    Jacobs, I; Bell, D G; Pope, J; Lee, W

    1987-08-01

    Recent studies carried out in the United States and Sweden have demonstrated that strength training can improve +Gz acceleration tolerance. Based on these findings, the Canadian Forces have introduced a training program for aircrew of high performance aircraft. This report describes the changes in physical fitness components considered relevant to +Gz tolerance after 12 weeks of training with this program. Prior to beginning training, 45 military personnel were tested, but only 20 completed a minimum of 24 training sessions. The following variables were measured in these 20 subjects before and after training: maximal strength of several large muscle groups during isokinetic contractions, maximal aerobic power and an endurance fitness index, maximal anaerobic power, anthropometric characteristics, and maximal expiratory pressure generated during exhalation. Training involved hydraulic resistance circuit training 2-4 times/week. The circuit consisted of 3 consecutive sets at each of 8 stations using Hydra-Gym equipment. The exercise:rest ratio was 20:40 s for the initial 4 training weeks and was then changed to 30:50. After training the changes in anthropometric measurements suggested that lean body mass was increased. Small, but significant, increases were also measured in muscle strength during bench press, biceps curls, squats, knee extension, and knee flexion. Neither maximal anaerobic power (i.e. muscular endurance) nor maximal expiratory pressure were changed after the training. Indices of endurance fitness were also increased in the present study. The relatively small increases in strength are probably due to the design of the exercise:rest ratio which resulted in improved strength and aerobic fitness.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Fosfomycin and Tobramycin in Combination Downregulate Nitrate Reductase Genes narG and narH, Resulting in Increased Activity against Pseudomonas aeruginosa under Anaerobic Conditions

    PubMed Central

    McCaughey, Gerard; Gilpin, Deirdre F.; Schneiders, Thamarai; Hoffman, Lucas R.; McKevitt, Matt; Elborn, J. Stuart

    2013-01-01

    The activity of aminoglycosides, which are used to treat Pseudomonas aeruginosa respiratory infection in cystic fibrosis (CF) patients, is reduced under the anaerobic conditions that reflect the CF lung in vivo. In contrast, a 4:1 (wt/wt) combination of fosfomycin and tobramycin (F:T), which is under investigation for use in the treatment of CF lung infection, has increased activity against P. aeruginosa under anaerobic conditions. The aim of this study was to elucidate the mechanisms underlying the increased activity of F:T under anaerobic conditions. Microarray analysis was used to identify the transcriptional basis of increased F:T activity under anaerobic conditions, and key findings were confirmed by microbiological tests, including nitrate utilization assays, growth curves, and susceptibility testing. Notably, growth in subinhibitory concentrations of F:T, but not tobramycin or fosfomycin alone, significantly downregulated (P < 0.05) nitrate reductase genes narG and narH, which are essential for normal anaerobic growth of P. aeruginosa. Under anaerobic conditions, F:T significantly decreased (P < 0.001) nitrate utilization in P. aeruginosa strains PAO1, PA14, and PA14 lasR::Gm, a mutant known to exhibit increased nitrate utilization. A similar effect was observed with two clinical P. aeruginosa isolates. Growth curves indicate that nitrate reductase transposon mutants had reduced growth under anaerobic conditions, with these mutants also having increased susceptibility to F:T compared to the wild type under similar conditions. The results of this study suggest that downregulation of nitrate reductase genes resulting in reduced nitrate utilization is the mechanism underlying the increased activity of F:T under anaerobic conditions. PMID:23959314

  14. Acute response of high-intensity and traditional resistance exercise on anaerobic power.

    PubMed

    Austad, Mark A; Gay, Chip R; Murray, Steven R; Pettitt, Robert W

    2013-09-01

    Quantifying the maximal work capacity (W') above the aerobic critical power (CP) has emerged as a method for estimating anaerobic work capacity. Slower cadence, lower-load resistance training (RT), colloquially referred to as high-intensity training (HIT), is purported to be a better metabolic stressor than faster cadence higher-load RT, but to date, this belief has not been supported by research. We compared the acute effects of HIT and traditional RT bouts on average power within a 150-second time period (P(150 s)), CP, and W', as measured from a 3-minute all-out exercise test using cycling ergometry (3 MT). Eight recreationally active male subjects (mean ± SD: age 22 ± 2 years, body mass 85 ± 14 kg, and height 18 ± 9 cm) completed a baseline 3 MT 10 repetition maximum testing on leg press and leg extension machines, and post-bout 3 MTs after an HIT (4:2 second cadence) or a traditional RT bout (1:1 second cadence). Measurements of CP from the 3 MTs were similar between the baseline, post-HIT (α = 0.96), and post-traditional RT bouts (α = 0.98). Neither HIT (269.2 ± 51.3 W) nor traditional RT (275.1 ± 51.3 W) evoked depreciations (p > 0.05) in P(150 s) from the baseline (275.1 ± 45.4 W). Moreover, estimates of W' at the baseline (8.3 ± 3.2 kJ) were unaffected (p > 0.05) either by the HIT (7.6 ± 2.3 kJ) or by the traditional RT (8.3 ± 1.3 kJ) bouts. These data indicate that the 4:2 cadence is insufficient to exhaust a person's capacity for high-intensity work. Longer RT durations, either by slower cadences or by multiple sets, are necessary to evoke substantive declines on W' and should be investigated.

  15. Inter-individual Variability in Soccer Players of Different Age Groups Playing Different Positions

    PubMed Central

    Nikolaidis, Pantelis; Ziv, Gal; Lidor, Ronnie; Arnon, Michal

    2014-01-01

    The purpose of this study was twofold: (a) to profile physical characteristics and motor abilities of three age groups of soccer players – under 14 years, 14–17, and over 17, playing different positions – goalkeepers, defenders, midfielders, and forwards; and (b) to examine the inter-individual variability among the players in each age group in all physical and physiological measurements performed in the study. In addition, anthropometric, power, strength, and flexibility tests were administered. Findings showed large inter-individual variability in all three age groups and in all playing positions. Differences between playing positions were found only in the 14–17 group (body mass) and in the over-17 group (body height, body mass, fat-free mass, and mean power in the Wingate Anaerobic Test). Due to the observed large inter-individual variability, it was concluded that the findings obtained in the physical and physiological tests should be interpreted with caution when attempting to differentiate between successful and unsuccessful soccer players, as well as when trying to predict future success in soccer. PMID:25031689

  16. Performance determinants of fixed gear cycling during criteriums.

    PubMed

    Babault, Nicolas; Poisson, Maxime; Cimadoro, Guiseppe; Cometti, Carole; Païzis, Christos

    2018-06-17

    Nowadays, fixed gear competitions on outdoor circuits such as criteriums are regularly organized worldwide. To date, no study has investigated this alternative form of cycling. The purpose of the present study was to examine fixed gear performance indexes and to characterize physiological determinants of fixed gear cyclists. This study was carried out in two parts. Part 1 (n = 36) examined correlations between performance indexes obtained during a real fixed gear criterium (time trial, fastest laps, averaged lap time during races, fatigue indexes) and during a sprint track time trial. Part 2 (n = 9) examined correlations between the recorded performance indexes and some aerobic and anaerobic performance outputs (VO 2max , maximal aerobic power, knee extensor and knee flexor maximal voluntary torque, vertical jump height and performance during a modified Wingate test). Results from Part 1 indicated significant correlations between fixed gear final performance (i.e. average lap time during the finals) and single lap time (time trial, fastest lap during races and sprint track time trial). In addition, results from Part 2 revealed significant correlations between fixed gear performance and aerobic indicators (VO 2max and maximal aerobic power). However, no significant relationship was obtained between fixed gear cycling and anaerobic qualities such as strength. Similarly to traditional cycling disciplines, we concluded that fixed gear cycling is mainly limited by aerobic capacity, particularly criteriums final performance. However, specific skills including technical competency should be considered.

  17. The effect of different exercise protocols and regression-based algorithms on the assessment of the anaerobic threshold.

    PubMed

    Zuniga, Jorge M; Housh, Terry J; Camic, Clayton L; Bergstrom, Haley C; Schmidt, Richard J; Johnson, Glen O

    2014-09-01

    The purpose of this study was to examine the effect of ramp and step incremental cycle ergometer tests on the assessment of the anaerobic threshold (AT) using 3 different computerized regression-based algorithms. Thirteen healthy adults (mean age and body mass [SD] = 23.4 [3.3] years and body mass = 71.7 [11.1] kg) visited the laboratory on separate occasions. Two-way repeated measures analyses of variance with appropriate follow-up procedures were used to analyze the data. The step protocol resulted in greater mean values across algorithms than the ramp protocol for the V[Combining Dot Above]O2 (step = 1.7 [0.6] L·min and ramp = 1.5 [0.4] L·min) and heart rate (HR) (step = 133 [21] b·min and ramp = 124 [15] b·min) at the AT. There were no significant mean differences, however, in power outputs at the AT between the step (115.2 [44.3] W) and the ramp (112.2 [31.2] W) protocols. Furthermore, there were no significant mean differences for V[Combining Dot Above]O2, HR, or power output across protocols among the 3 computerized regression-based algorithms used to estimate the AT. The current findings suggested that the protocol selection, but not the regression-based algorithms can affect the assessment of the V[Combining Dot Above]O2 and HR at the AT.

  18. Comparison of Sprint and Run Times with Performance on the Wingate Anaerobic Test.

    ERIC Educational Resources Information Center

    Tharp, Gerald D.; And Others

    1985-01-01

    Male volunteers were studied to examine the relationship between the Wingate Anaerobic Test (WAnT) and sprint-run times and to determine the influence of age and weight. Results indicate the WAnT is a moderate predictor of dash and run times but becomes a stronger predictor when adjusted for body weight. (Author/MT)

  19. Correcting the use of the term "power" in the strength and conditioning literature.

    PubMed

    Knudson, Duane V

    2009-09-01

    Many strength and conditioning papers have incorrectly adopted the colloquial use of the term "power" as a measure of short-term, high-intensity muscular performance despite a long history of research and editorials critical of this practice. This has lead to confusion, incorrect interpretations, and conflicting results in the literature. This paper summarizes the scientific evidence on external mechanical power as a short-term, high-intensity neuromuscular (anaerobic) performance or training variable. Many problems in the measurement and use of power in strength and conditioning research were identified, as well as problems in the use of the vertical jump as a field test of power. A critical review of the biomechanics, measurement, and training research does not support this colloquial use of the term "power." More research is needed that improves our understanding of the domains of muscular strength or neuromuscular performance, as well as partial correlation and multiple regression analyses to document the unique associations between these domains, biomechanical variables, training effects, and sport performance. Strength and conditioning research should limit the use of the term power to the true mechanical definition and provide several specific and measurement details on this measurement.

  20. Products of anaerobic phloroglucinol degradation by Coprococcus sp. Pe15.

    PubMed

    Tsai, C G; Gates, D M; Ingledew, W M; Jones, G A

    1976-02-01

    Under anaerobic conditions, resting cell suspensions of Coprococcus sp. Pe15 degraded 1 molecule of phloroglucinol to 2 molecules of acetic acid and 2 molecules of carbon dioxide. The organism metabolized the flavonoids rhamnetin and quercetin anaerobically in 20% rumen fluid medium but failed to grow under similar conditions at the expense of any of 39 other aromatic or flavonoid compounds tested.

  1. Anaerobic hydrolysis and acidification of organic substrates: determination of anaerobic hydrolytic potential.

    PubMed

    Rajagopal, Rajinikanth; Béline, Fabrice

    2011-05-01

    This study aimed to develop a biochemical-test mainly to evaluate the hydrolytic-potential of different substrates and to apply this test to characterize various organic substrates. Outcome of this study can be used for optimization of the WWTPs through enhancement of N/P removal or anaerobic digestion. Out of four series of batch experiments, the first two tests were conducted to determine the optimal operating conditions (test duration, inoculum-ratio etc.) for the hydrolytic-potential test using secondary and synthetically-prepared sludges. Based on the results (generation of CODs, pH and VFA), test duration was fixed between 6 and 7d allowing to attain maximum hydrolysis and to avoid methanogenesis. Effect of inoculum-ratios on acid fermentation of sludge was not significantly noticed. Using this methodology, third and fourth tests were performed to characterize various organic substrates namely secondary, pre-treated sludge, pig and two different cattle slurries. VFA production was shown to be substantially dependent on substrates types. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Rapid Methods for Biochemical Testing of Anaerobic Bacteria

    PubMed Central

    Schreckenberger, Paul C.; Blazevic, Donna J.

    1974-01-01

    Rapid biochemical tests for nitrate, indole, gelatin, starch, esculin, and o-nitrophenyl-β-D-galactopyranoside were performed on 112 strains of anaerobic bacteria. All tests were incubated under aerobic conditions, and results were recorded within 4 h. The tests for nitrate, indole, and starch showed a 95% or greater correlation when compared to the standard biochemical tests. Tests for esculin and gelatin showed an agreement of 86 and 77%, respectively. PathoTec test strips for nitrate, indole, esculin, o-nitrophenyl-β-D-galactopyranoside, Voges-Proskauer, and urease were also tested and showed encouraging results. PMID:4613268

  3. Gross efficiency and energy expenditure in kayak ergometer exercise.

    PubMed

    Gomes, B B; Mourão, L; Massart, A; Figueiredo, P; Vilas-Boas, J P; Santos, A M C; Fernandes, R J

    2012-08-01

    We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with VO2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to VO2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg - 1.min - 1, and 10.10±1.08%. Male kayakers presented higher VO2max, power output and gross efficiency at the VO2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at VO2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Maximal Aerobic and Anaerobic Power Generation in Large Crocodiles versus Mammals: Implications for Dinosaur Gigantothermy

    PubMed Central

    Seymour, Roger S.

    2013-01-01

    Inertial homeothermy, the maintenance of a relatively constant body temperature that occurs simply because of large size, is often applied to large dinosaurs. Moreover, biophysical modelling and actual measurements show that large crocodiles can behaviourally achieve body temperatures above 30°C. Therefore it is possible that some dinosaurs could achieve high and stable body temperatures without the high energy cost of typical endotherms. However it is not known whether an ectothermic dinosaur could produce the equivalent amount of muscular power as an endothermic one. To address this question, this study analyses maximal power output from measured aerobic and anaerobic metabolism in burst exercising estuarine crocodiles, Crocodylusporosus , weighing up to 200 kg. These results are compared with similar data from endothermic mammals. A 1 kg crocodile at 30°C produces about 16 watts from aerobic and anaerobic energy sources during the first 10% of exhaustive activity, which is 57% of that expected for a similarly sized mammal. A 200 kg crocodile produces about 400 watts, or only 14% of that for a mammal. Phosphocreatine is a minor energy source, used only in the first seconds of exercise and of similar concentrations in reptiles and mammals. Ectothermic crocodiles lack not only the absolute power for exercise, but also the endurance, that are evident in endothermic mammals. Despite the ability to achieve high and fairly constant body temperatures, therefore, large, ectothermic, crocodile-like dinosaurs would have been competitively inferior to endothermic, mammal-like dinosaurs with high aerobic power. Endothermy in dinosaurs is likely to explain their dominance over mammals in terrestrial ecosystems throughout the Mesozoic. PMID:23861968

  5. Subtyping children with developmental coordination disorder based on physical fitness outcomes.

    PubMed

    Aertssen, Wendy; Bonney, Emmanuel; Ferguson, Gillian; Smits-Engelsman, Bouwien

    2018-05-28

    Children with Developmental Coordination Disorder (DCD) are known to have poor physical fitness. However, differentiating homogenous subgroups of DCD using fitness performance has not yet been established. Therefore the purpose of this study was to identify subtypes in children with and without DCD using measures of physical fitness. Children (aged 6-10 years, n = 217) constituted the sample for this study. They were assessed on 1) aerobic fitness (20m Shuttle Run test), 2) anaerobic fitness (Muscle Power Sprint Test), 3) isometric muscle strength (handheld dynamometry) 4) functional upper and lower body strength (Functional Strength Measurement) and 5) motor coordination [Movement Assessment Battery for Children-2nd edition (MABC-2) test]. The Ward method was used to identify the various clusters. Five subtypes emerged in the entire sample. In the typically developing (TD) children mainly 2 subtypes (number 5 and 2) were found containing 89% of the TD children (n = 55), with the largest group demonstrating above average performance on all measures (cluster 5). Children in subtype 2 had just above average motor coordination and good aerobic fitness but lower muscle strength. Subtypes 1, 3 and 4 were clearly "DCD" clusters, however they showed difference in fitness performance. Subtype 1 contained children with DCD who showed poor performance on all fitness outcomes (n = 45). Children with DCD in subtype 3 had poor aerobic but average strength and anaerobic fitness (n = 48). Subtype 4 contained children with DCD (n = 45) who had good muscle strength and anaerobic fitness. Of these, 36% were at risk of DCD while 24% had definite motor coordination problems. Our findings indicate that children with and without DCD demonstrate heterogeneous physical fitness profiles. The majority of the children (66%) with DCD belonged to subtypes with lower fitness performance. Further studies are needed to confirm these findings in other samples of DCD children. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Physiological characteristics of America's Cup sailors.

    PubMed

    Bernardi, Marco; Quattrini, Filippo M; Rodio, Angelo; Fontana, Giuseppe; Madaffari, Andrea; Brugnoli, Marco; Marchetti, Marco

    2007-08-01

    The aim of this study was to assess the physiological profile of America's Cup grinders and mastmen, by measuring energy expenditure during sailing and assessing their aerobic and anaerobic fitness. The study focused on estimating the energy used during grinding activity, by measuring oxygen uptake (VO(2)) during sail setting in real sailing conditions. In the laboratory, using an arm-cranking ergometer, we measured VO(2peak) during an incremental maximal exercise test and total energy expended during the effort and recovery phases of an all-out test that simulated grinding activity, in six grinders and mastmen and ten sailors of the same crew. Total energy used during grinding corresponded to 45% (s = 9) and 51% (s = 5) of that used in the all-out test (234 kJ, s = 21.7) for tacks and gybes, respectively. In both grinding activity and the all-out test, VO(2) increased during and after the effort. The "VO(2) top value" was 53% (s = 8.6), 68% (s = 5.5), and 78% (s = 3.1) of VO(2peak) (4.7 l . min(-1), s = 0.43) in tacks, gybes, and the all-out test, respectively. During fast sequences of grinding activity, the "VO(2) top value" reached 65% (s = 7.1) VO(2peak) in tacks and 91% (s = 3.3) VO(2peak) in gybes. Our results suggest that grinders and mastmen are characterized by a high anaerobic capacity but their performance can be improved by powering aerobic fitness, to increase this energy contribution to all-out efforts and to guarantee fast recovery when grinding activity is repeated with short rest intervals.

  7. The effects of six weeks of supplementation with multi-ingredient performance supplements and resistance training on anabolic hormones, body composition, strength, and power in resistance-trained men

    PubMed Central

    2012-01-01

    Background Resistance training (RT) enhances muscle protein synthesis and hypertrophy while increasing strength and power. Some multi-ingredient performance supplements (MIPS) have been shown to augment the physiological improvements associated with RT. The purpose of this study was to investigate the impact of specific pre- and post-workout MIPS on anabolic hormones, body composition, muscle strength, and power in resistance-trained men participating in a periodized RT program. Methods Twenty-four ( mean ± SE; 24.0 ± 0.9 years; 180.5 ± 5.8 cm; 83.7 ± 0.5 kg) resistance-trained men completed 6 wks of periodized RT (3x/wk). Participants were assigned to one of two groups based upon maximal voluntary contraction of the quadriceps (Biodex) to lean mass (LM) ratio. Group 1 (n = 13; MIPS) consumed one serving of NO-Shotgun® (whey protein, casein protein, branched-chain amino acids, creatine, beta alanine, and caffeine) before each workout and one serving of NO-Synthesize® (whey protein, casein protein, branched-chain amino acids, creatine, and beta alanine; Vital Pharmaceuticals, Inc., Davie, FL) immediately after each workout and on non-RT days. Group 2 (n = 11; Placebo; PLA) consumed a flavor-matched isocaloric maltodextrin placebo. Serum insulin-like growth factor 1, human growth hormone, testosterone, body composition (DXA), circumferences, 1-repetition maximal strength (1RM) of the upper (chest press) and lower body (leg press), and anaerobic power (Wingate test) were assessed before and after the intervention. Statistical analysis included a 2 × 2 (group x time) ANOVA with repeated measures. Tukey LSD post hoc tests were used to examine pairwise differences. Significance was set at p < 0.05. Results There was a main time effect (p = 0.035) for testosterone to increase, but no differences between groups were observed. There were no differences in the other blood hormones. Group x time interactions were observed for LM (MIPS: PRE, 62.9 ± 2.1 to POST, 65.7 ± 2.0 vs. PLA: PRE, 63.5 ± 2.3 to POST, 64.8 ± 2.5 kg; p = 0.017). Only a main effect of time was noted for circumference measures. Both groups increased upper and lower body 1RM strength to a similar degree. MIPS significantly increased peak anaerobic power (PRE, 932.7 ± 172.5 W vs. POST, 1119.2 ± 183.8 W, p = 0.002) while PLA remained unchanged (PRE, 974.4 ± 44.1 W vs. POST, 1033.7 ± 48.6 W, p = 0.166). Conclusion Consumption of MIPS during the course of a periodized RT program facilitated training-induced improvement in LM in trained males, whereas the consumption of PLA did not. MIPS improved measures of anaerobic power while PLA did not. PMID:23153110

  8. Effect of Red Bull energy drink on repeated Wingate cycle performance and bench-press muscle endurance.

    PubMed

    Forbes, Scott C; Candow, Darren G; Little, Jonathan P; Magnus, Charlene; Chilibeck, Philip D

    2007-10-01

    The purpose of this study was to determine the effects of Red Bull energy drink on Wingate cycle performance and muscle endurance. Healthy young adults (N = 15, 11 men, 4 women, 21 +/- 5 y old) participated in a crossover study in which they were randomized to supplement with Red Bull (2 mg/kg body mass of caffeine) or isoenergetic, isovolumetric, noncaffeinated placebo, separated by 7 d. Muscle endurance (bench press) was assessed by the maximum number of repetitions over 3 sets (separated by 1-min rest intervals) at an intensity corresponding to 70% of baseline 1-repetition maximum. Three 30-s Wingate cycling tests (load = 0.075 kp/kg body mass), with 2 min recovery between tests, were used to assess peak and average power output. Red Bull energy drink significantly increased total bench-press repetitions over 3 sets (Red Bull = 34 +/- 9 vs. placebo = 32 +/- 8, P %%%lt; 0.05) but had no effect on Wingate peak or average power (Red Bull = 701 +/- 124 W vs. placebo = 700 +/- 132 W, Red Bull = 479 +/- 74 W vs. placebo = 471 +/- 74 W, respectively). Red Bull energy drink significantly increased upper body muscle endurance but had no effect on anaerobic peak or average power during repeated Wingate cycling tests in young healthy adults.

  9. Oxyrase, a method which avoids CO2 in the incubation atmosphere for anaerobic susceptibility testing of antibiotics affected by CO2.

    PubMed

    Spangler, S K; Appelbaum, P C

    1993-02-01

    The Oxyrase agar dilution method, with exclusion of CO2 from the environment, was compared with the reference agar dilution method recommended by the National Committee for Clinical Laboratory Standards (anaerobic chamber with 10% CO2) to test the susceptibility of 51 gram-negative and 43 gram-positive anaerobes to azithromycin and erythromycin. With the Oxyrase method, anaerobiosis was achieved by incorporation of the O2-binding enzyme Oxyrase in addition to susceptibility test medium, antibiotic, and enzyme substrates into the upper level of a biplate. Plates were covered with a Brewer lid and incubated in ambient air. With azithromycin, Oxyrase yielded an MIC for 50% of strains tested (MIC50) and MIC90 of 2.0 and 8.0 micrograms/ml, compared to 8.0 and > 32.0 micrograms/ml in standard anaerobic conditions. At a breakpoint of 8.0 micrograms/ml, 90.4% of strains were susceptible to azithromycin with Oxyrase, compared to 53.2% in the chamber. The corresponding erythromycin MIC50 and MIC90 were 1.0 and 8.0 micrograms/ml with Oxyrase, compared to 4.0 and > 32.0 micrograms/ml by the reference method, with 89.3% of strains susceptible at a breakpoint of 4 micrograms/ml with Oxyrase, compared to 60.6% in CO2. Exclusion of CO2 from the anaerobic atmosphere when testing for susceptibility to azalides and macrolides yielded lower MICs, which may lead to a reconsideration of the role played by these compounds in treatment of infections caused by these strains.

  10. Alkali-assisted membrane cleaning for fouling control of anaerobic ceramic membrane bioreactor.

    PubMed

    Mei, Xiaojie; Quek, Pei Jun; Wang, Zhiwei; Ng, How Yong

    2017-09-01

    In this study, a chemically enhanced backflush (CEB) cleaning method using NaOH solution was proposed for fouling mitigation in anaerobic membrane bioreactors (AnMBRs). Ex-situ cleaning tests revealed that NaOH dosages ranging from 0.05 to 1.30mmol/L had positive impacts on anaerobic biomass, while higher dosages (>1.30mmol/L) showed inhibition and/or toxic impacts. In-situ cleaning tests showed that anaerobic biomass could tolerate much higher NaOH concentrations due to the alkali consumption by anaerobic process and/or the buffering role of mixed liquor. More importantly, 10-20mmol-NaOH/L could significantly reduce membrane fouling rates (4-5.5 times over the AnMBR with deionized water backflush) and slightly improve methanogenic activities. COD removal efficiencies were over 87% and peaked at 20mmol-NaOH/L. However, extremely high NaOH concentration had adverse effects on filtration and treatment performance. Economic analysis indicated that 12mmol/L of NaOH was the cost-efficient and optimal fouling-control dosage for the CEB cleaning. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Methane enrichment digestion experiments at the anaerobic experimental test unit at Walt Disney World. Final report, March 1989-August 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava, V.J.; Hill, A.H.

    1993-06-01

    The goal of the project was to determine the technical feasibility of utilizing a novel concept in anaerobic digestion, in-situ methane enrichment digestion or MED for producing utility-grade gas from a pilot-scale anaerobic digester. MED tests conducted during this program consistently achieved digester product gas with a methane (CH4) content of greater than 90% (on a dry-, nitrogen-free basis). The MED concept, because it requires relatively simple equipment and modest energy input, has the potential to simplify gas cleanup requirements and substantially reduce the cost of converting wastes and biomass to pipeline quality gas.

  12. The usefulness of the anaerobic threshold in the assessment and prognostic evaluation of the patient with dyspnea.

    PubMed

    Madonna, Rosalinda; De Caterina, Raffaele; Bolli, Roberto

    2012-01-01

    The anaerobic threshold (AT) is defined as the oxygen consumption level above which energy production becomes determined by anaerobic metabolism, which causes a sustained increase in lactate and metabolic acidosis. The AT, as measured by cardiopulmonary stress testing, is ubiquitously used to determine the prognosis and diagnosis of cardiovascular and respiratory diseases. This measurement can help clinicians in the functional evaluation of patients and as guidance for rehabilitation and therapy. This article reviews the pathophysiological aspects and methods of measurement of the AT during a cardiopulmonary stress test, and its clinical use in assessing cardiac and respiratory diseases.

  13. The comparison of cold-water immersion and cold air therapy on maximal cycling performance and recovery markers following strength exercises

    PubMed Central

    Hayter, Kane J.; Schumann, Moritz; Deakin, Glen B.

    2016-01-01

    This study examined the effects of cold-water immersion (CWI) and cold air therapy (CAT) on maximal cycling performance (i.e. anaerobic power) and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10) and female (n = 10) participants were randomised into either: CWI (15 min in 14 °C water to iliac crest) or CAT (15 min in 14 °C air) immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively). Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24), 48 (T48) and 72 (T72) h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05). However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90), T48 (8% ± 2%, ES = 0.64) and T72 (8% ± 7%, ES = 0.76). The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone. PMID:27069791

  14. Cross-Country Skiing Injuries and Training Methods.

    PubMed

    Nagle, Kyle B

    2015-01-01

    Cross-country skiing is a low injury-risk sport that has many health benefits and few long-term health risks. Some concern exists that cross-country skiing may be associated with a higher incidence of atrial fibrillation; however, mortality rates among skiers are lower than those among the general population. While continuing to emphasize aerobic and anaerobic training, training methods also should promote ski-specific strength training to increase maximum force and its rate of delivery and to build muscular endurance to maintain that power through a race. Multiple tests are available to monitor training progress. Which tests are most appropriate depends on the specific events targeted. In addition to laboratory-based tests, there also are many simpler, more cost-effective tests, such as short time trials, that can be used to monitor training progress and predict performance particularly at the junior skier level where access and cost may be more prohibitive.

  15. In vitro activity of ABT-492 against anaerobic bacteria.

    PubMed

    Sillerström, E; Wahlund, E; Nord, C E

    2004-06-01

    The purpose of the study was to determine the in vitro activity of ABT-492 compared with that of other antimicrobial agents against anaerobic bacteria. The activity of ABT-492 was investigated against 369 clinical isolates of anaerobic bacteria by the agar dilution method and was compared with that of moxifloxacin, piperacillin, cefoxitin, imipenem, clindamycin and metronidazole. ABT-492 and imipenem were the most active antimicrobial agents tested.

  16. Nutrients recycling strategy for microalgae-based CO2 mitigation system

    NASA Astrophysics Data System (ADS)

    E, Xinyi

    Coal-fired electricity production is the major emitter of CO2 and other greenhouse gases including NOx and SO x. Microalgae-based CO2 mitigation systems have been proposed to reduce the net CO2 emission from coal-fired power plants. This study focused on developing an optimum culture media and exploring the possibilities for recycling nutrients, which were added as commercial mineralized chemicals at the beginning of cultivation. In order to release the nutrients embedded in the cells so that they can be used as a nutrient source for new cells, Scenedesmus biomass was digested by anaerobic bacteria. Results showed that thermal pretreatment enhanced the methane production rate for the first 7 days of digestion. Three operational factors were tested: heating temperature, heating duration and NaOH dosage. The combination of 10 min heating with 3˜6% NaOH at 50 °C gave the highest cell wall destruction for all samples except oven-dried algae. The anaerobic digestate, rich in mineralized nutrients including ammonium and phosphate, potassium and magnesium ions, was tested as a possible nutrient source for the algae cultivation. To cope with the high solid content of the digestates, the dosage of the digestates was reduced or the solid particles were removed prior to addition to the microalgae. Both approaches worked well in terms of providing nutrients with minimal effect on light penetration. Using digestates without any sterilization did not cause contamination or other deleterious effects on the Scenedesmus growth rate. Harvesting microalgae cells was critical to ensure a continuous and robust growth rate. The used media could be recycled at least four times without altering the algae growth. Nutrient replenishment was the key for a healthy culture when used media was incorporated. The combination of used media and digestates can sustain a normal algae growth. Life cycle assessment was conducted on the system including the photobioreactor, the anaerobic digester, the biomass settling and dewatering and used media and nutrient recycling. Considering methane as the energy source, the overall energy return of the system was 2.4. CO2 mitigation rate was about 39% under current mitigation system. KEYWORDS: Scenedesmus, urea, anaerobic digestion, used media, life cycle assessment.

  17. Characterization of a unique class C acid phosphatase from Clostridium perfringens.

    PubMed

    Reilly, Thomas J; Chance, Deborah L; Calcutt, Michael J; Tanner, John J; Felts, Richard L; Waller, Stephen C; Henzl, Michael T; Mawhinney, Thomas P; Ganjam, Irene K; Fales, William H

    2009-06-01

    Clostridium perfringens is a gram-positive anaerobe and a pathogen of medical importance. The detection of acid phosphatase activity is a powerful diagnostic indicator of the presence of C. perfringens among anaerobic isolates; however, characterization of the enzyme has not previously been reported. Provided here are details of the characterization of a soluble recombinant form of this cell-associated enzyme. The denatured enzyme was approximately 31 kDa and a homodimer in solution. It catalyzed the hydrolysis of several substrates, including para-nitrophenyl phosphate, 4-methylumbelliferyl phosphate, and 3' and 5' nucleoside monophosphates at pH 6. Calculated K(m)s ranged from 0.2 to 0.6 mM with maximum velocity ranging from 0.8 to 1.6 micromol of P(i)/s/mg. Activity was enhanced in the presence of some divalent cations but diminished in the presence of others. Wild-type enzyme was detected in all clinical C. perfringens isolates tested and found to be cell associated. The described enzyme belongs to nonspecific acid phosphatase class C but is devoid of lipid modification commonly attributed to this class.

  18. Characterization of a Unique Class C Acid Phosphatase from Clostridium perfringens▿

    PubMed Central

    Reilly, Thomas J.; Chance, Deborah L.; Calcutt, Michael J.; Tanner, John J.; Felts, Richard L.; Waller, Stephen C.; Henzl, Michael T.; Mawhinney, Thomas P.; Ganjam, Irene K.; Fales, William H.

    2009-01-01

    Clostridium perfringens is a gram-positive anaerobe and a pathogen of medical importance. The detection of acid phosphatase activity is a powerful diagnostic indicator of the presence of C. perfringens among anaerobic isolates; however, characterization of the enzyme has not previously been reported. Provided here are details of the characterization of a soluble recombinant form of this cell-associated enzyme. The denatured enzyme was ∼31 kDa and a homodimer in solution. It catalyzed the hydrolysis of several substrates, including para-nitrophenyl phosphate, 4-methylumbelliferyl phosphate, and 3′ and 5′ nucleoside monophosphates at pH 6. Calculated Kms ranged from 0.2 to 0.6 mM with maximum velocity ranging from 0.8 to 1.6 μmol of Pi/s/mg. Activity was enhanced in the presence of some divalent cations but diminished in the presence of others. Wild-type enzyme was detected in all clinical C. perfringens isolates tested and found to be cell associated. The described enzyme belongs to nonspecific acid phosphatase class C but is devoid of lipid modification commonly attributed to this class. PMID:19363079

  19. Low dose creatine supplementation enhances sprint phase of 400 meters swimming performance.

    PubMed

    Anomasiri, Wilai; Sanguanrungsirikul, Sompol; Saichandee, Pisut

    2004-09-01

    This study demonstrated the effect of low dose creatine supplement (10 g. per day) on the sprinting time in the last 50 meters of 400 meters swimming competition, as well as the effect on exertion. Nineteen swimmers in the experimental group received creatine monohydrate 5 g with orange solution 15 g, twice per day for 7 days and nineteen swimmers in the control group received the same quantity of orange solution. The results showed that the swimmers who received creatine supplement lessened the sprinting time in the last 50 meters of 400 meters swimming competition than the control group. (p<0.05). The results of Wingate test (anaerobic power, anaerobic capacity and fatigue index) compared between pre and post supplementation. There was significant difference at p<0.05 in the control group from training effect whereas there was significant difference at p<0.000 from training effect and creatine supplement in the experiment group. Therefore, the creatine supplement in amateur swimmers in the present study enhanced the physical performance up to the maximum capacity.

  20. Evaluation of anaerobic threshold in non-pregnant and pregnant rats.

    PubMed

    Netto, Aline Oliveira; Macedo, Nathália C D; Gallego, Franciane Q; Sinzato, Yuri K; Volpato, Gustavo T; Damasceno, Débora C

    2017-01-01

    Several studies present different methodologies and results about intensity exercise, and many of them are performed in male rats. However, the impact of different type, intensity, frequency and duration of exercise on female rats needs more investigation. From the analysis of blood lactate concentration during lactate minimum test (LacMin) in the swimming exercise, the anaerobic threshold (AT) was identified, which parameter is defined as the transition point between aerobic and anaerobic metabolism. LacMin test is considered a good indicator of aerobic conditioning and has been used in prescription of training in different exercise modalities. However, there is no evidence of LacMin test in female rats. The objective was to determine AT in non-pregnant and pregnant Wistar rats. The LacMin test was performed and AT defined for mild exercise intensity was from a load equivalent to 1% of body weight (bw), moderate exercise as carrying 4% bw and severe intensity as carrying 7% bw. In pregnant rats, the AT was reached at a lower loading from 5.0% to 5.5% bw, while in non-pregnant the load was from 5.5% to 6.0% bw. Thus, this study was effective to identify exercise intensities in pregnant and non-pregnant rats using anaerobic threshold by LacMin test.

  1. Anaerobic digestion of slaughterhouse waste: main process limitations and microbial community interactions.

    PubMed

    Palatsi, J; Viñas, M; Guivernau, M; Fernandez, B; Flotats, X

    2011-02-01

    Fresh pig/cattle slaughterhouse waste mixtures, with different lipid-protein ratios, were characterized and their anaerobic biodegradability assessed in batch tests. The resultant methane potentials were high (270-300 L(CH4) kg(-1)(COD)) making them interesting substrates for the anaerobic digestion process. However, when increasing substrate concentrations in consecutive batch tests, up to 15 g(COD) kg(-1), a clear inhibitory process was monitored. Despite the reported severe inhibition, related to lipid content, the system was able to recover activity and successfully degrade the substrate. Furthermore, 16SrRNA gene-based DGGE results showed an enrichment of specialized microbial populations, such as β-oxidizing/proteolitic bacteria (Syntrophomonas sp., Coprothermobacter sp. and Anaerobaculum sp.), and syntrophic methanogens (Methanosarcina sp.). Consequently, the lipid concentration of substrate and the structure of the microbial community are the main limiting factors for a successful anaerobic treatment of fresh slaughterhouse waste. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Determination of the effects of playing soccer on physical fitness in individuals with transtibial amputation.

    PubMed

    Guchan, Zehra; Bayramlar, Kezban; Ergun, Nevin

    2017-06-01

    The aim of this paper is to determine the effects of playing soccer on various components of physical performance such as body composition, muscular endurance, anaerobic power, flexibility, balance, and speed of individuals with transtibial amputation. Twelve amputee football players aged 26.67±7.76 years and twelve sedentary individuals aged 33±6.7 years were involved in this study. Body composition, and isotonic and isometric endurance of trunk muscles were assessed. Vertical jump test, sit-and-reach test, modified Thomas test, Berg Balance Scale, L test, and figure-of-eight walk (F8W) test were used to assess other physical fitness parameters. The Body Mass Index, waist circumference and body fat percentages of the amputee soccer players were significantly lower than the sedentary amputees (P<0.05). The endurance of back extensors was significantly higher in the soccer group (119.33±47.15 s) than the endurance in the control group (26.25±15.96 s) (P<0.001). Subjects belonging to the soccer group had significantly higher anaerobic power than those in the control group (P<0.05). Flexibility, as assessed by the sit-and-reach test was significantly higher for the soccer group (P=0.002), whereas the modified Thomas test, which is also used to measure flexibility, indicated no significant difference among both groups (P>0.05). Balance was higher in the soccer group (P=0.023). The completion period of the F8W test was significantly lower in the soccer group (4.54±0.9 s) than in the control group (7.71±2.25 s) (P<0.001). No significant difference was observed in the numbers of steps measured during the F8W test (P=0.231). This is the first study which investigates the effects of sports on the physical fitness of individuals with transtibial amputation with the inclusion of a control group. Overall findings present the benefits of participating in playing soccer on physical fitness parameters of amputees, but further studies with randomized controlled trials, with larger populations, and with other sport branches should be conducted to motivate all amputees to participate in sports.

  3. Evaluation of biogas production potential by dry anaerobic digestion of switchgrass--animal manure mixtures.

    PubMed

    Ahn, H K; Smith, M C; Kondrad, S L; White, J W

    2010-02-01

    Anaerobic digestion is a biological method used to convert organic wastes into a stable product for land application with reduced environmental impacts. The biogas produced can be used as an alternative renewable energy source. Dry anaerobic digestion [>15% total solid (TS)] has an advantage over wet digestion (<10% TS) because it allows for the use of a smaller volume of reactor and because it reduces wastewater production. In addition, it produces a fertilizer that is easier to transport. Performance of anaerobic digestion of animal manure-switchgrass mixture was evaluated under dry (15% TS) and thermophilic conditions (55 degrees C). Three different mixtures of animal manure (swine, poultry, and dairy) and switchgrass were digested using batch-operated 1-L reactors. The swine manure test units showed 52.9% volatile solids (VS) removal during the 62-day trial, while dairy and poultry manure test units showed 9.3% and 20.2%, respectively. Over the 62 day digestion, the swine manure test units yielded the highest amount of methane 0.337 L CH4/g VS, while the dairy and poultry manure test units showed very poor methane yield 0.028 L CH4/g VS and 0.002 L CH4/g VS, respectively. Although dairy and poultry manure performed poorly, they may still have high potential as biomass for dry anaerobic digestion if appropriate designs are developed to prevent significant volatile fatty acid (VFA) accumulation and pH drop.

  4. Improving balance, mobility, and dual-task performance in an adolescent with cerebral palsy: A case report.

    PubMed

    Fisher-Pipher, Sarah; Kenyon, Lisa K; Westman, Marci

    2017-07-01

    Improving functional mobility is often a desired outcome for adolescents with cerebral palsy (CP). Traditional neurorehabilitation approaches are frequently directed at impairments; however, improvements may not be carried over into functional mobility. The purpose of this case report was to describe the examination, intervention, and outcomes of a task-oriented physical therapy intervention program to improve dynamic balance, functional mobility, and dual-task performance in an adolescent with CP. The participant was a 15-year-old girl with spastic triplegic CP (Gross Motor Classification System Level II). Examination procedures included the Canadian Occupational Performance Measure, 6-minute walk test, Muscle Power Sprint Test, 10 x 5-meter sprint test, Timed Up and Down Stairs Test, Gross Motor Function Measure, Gillette Functional Assessment Questionnaire, and functional lower extremity strength tests. Intervention focused on task-oriented dynamic balance and mobility tasks that incorporated coordination and speed demands as well as task-specific lower extremity and trunk strengthening activities. Dual task demands were integrated into all intervention activities. Post-intervention testing revealed improvements in cardiovascular endurance, anaerobic power, agility, stair climbing, gross motor skills, and mobility. The participant appeared to benefit from a task-oriented program to improve dynamic balance, functional mobility, and dual-task performance.

  5. Development of Electroactive and Anaerobic Ammonium-Oxidizing (Anammox) Biofilms from Digestate in Microbial Fuel Cells.

    PubMed

    Di Domenico, Enea Gino; Petroni, Gianluca; Mancini, Daniele; Geri, Alberto; Di Palma, Luca; Ascenzioni, Fiorentina

    2015-01-01

    Microbial Fuel cells (MFCs) have been proposed for nutrient removal and energy recovery from different wastes. In this study the anaerobic digestate was used to feed H-type MFC reactors, one with a graphite anode preconditioned with Geobacter sulfurreducens and the other with an unconditioned graphite anode. The data demonstrate that the digestate acts as a carbon source, and even in the absence of anode preconditioning, electroactive bacteria colonise the anodic chamber, producing a maximum power density of 172.2 mW/m(2). The carbon content was also reduced by up to 60%, while anaerobic ammonium oxidation (anammox) bacteria, which were found in the anodic compartment of the reactors, contributed to nitrogen removal from the digestate. Overall, these results demonstrate that MFCs can be used to recover anammox bacteria from natural sources, and it may represent a promising bioremediation unit in anaerobic digestor plants for the simultaneous nitrogen removal and electricity generation using digestate as substrate.

  6. Development of Electroactive and Anaerobic Ammonium-Oxidizing (Anammox) Biofilms from Digestate in Microbial Fuel Cells

    PubMed Central

    Petroni, Gianluca; Mancini, Daniele; Geri, Alberto; Palma, Luca Di

    2015-01-01

    Microbial Fuel cells (MFCs) have been proposed for nutrient removal and energy recovery from different wastes. In this study the anaerobic digestate was used to feed H-type MFC reactors, one with a graphite anode preconditioned with Geobacter sulfurreducens and the other with an unconditioned graphite anode. The data demonstrate that the digestate acts as a carbon source, and even in the absence of anode preconditioning, electroactive bacteria colonise the anodic chamber, producing a maximum power density of 172.2 mW/m2. The carbon content was also reduced by up to 60%, while anaerobic ammonium oxidation (anammox) bacteria, which were found in the anodic compartment of the reactors, contributed to nitrogen removal from the digestate. Overall, these results demonstrate that MFCs can be used to recover anammox bacteria from natural sources, and it may represent a promising bioremediation unit in anaerobic digestor plants for the simultaneous nitrogen removal and electricity generation using digestate as substrate. PMID:26273609

  7. Inhibitory effect of high phenol concentration in treating coal gasification wastewater in anaerobic biofilter.

    PubMed

    Li, Yajie; Tabassum, Salma; Chu, Chunfeng; Zhang, Zhenjia

    2018-02-01

    In this paper, the inhibition of methanogens by phenol in coal gasification wastewater (CGW) was investigated by both anaerobic toxicity tests and a lab-scale anaerobic biofilter reactor (AF). The anaerobic toxicity tests indicated that keeping the phenol concentration in the influent under 280mg/L could maintain the methanogenic activity. In the AF treating CGW, the result showed that adding glucose solution as co-substrate could be beneficial for the quick start-up of the reactor. The effluent chemical oxygen demand (COD) and total phenol reached 1200 and 100mg/L, respectively, and the methane production rate was 175mLCH 4 /gCOD/day. However, if the concentration of phenol was increased, the inhibition of anaerobic micro-organisms was irreversible. The threshold of total phenol for AF operation was 200-250mg/L. The extracellular polymeric substances (EPS) and particle size distribution of anaerobic granular sludge in the different stages were also examined, and the results indicated that the influence of toxicity in the system was more serious than its effect on flocculation of EPS. Moreover, the proportion of small size anaerobic granular sludge gradually increased from 10.2% to 34.6%. The results of high through-put sequencing indicated that the abundance of the Chloroflexi and Planctomycetes was inhibited by the toxicity of the CGW, and some shifts in the microbial community were observed at different stages. Copyright © 2017. Published by Elsevier B.V.

  8. A modeling approach to describe ZVI-based anaerobic system.

    PubMed

    Xiao, Xiao; Sheng, Guo-Ping; Mu, Yang; Yu, Han-Qing

    2013-10-15

    Zero-valent iron (ZVI) is increasingly being added into anaerobic reactors to enhance the biological conversion of various less biodegradable pollutants (LBPs). Our study aimed to establish a new structure model based on the Anaerobic Digestion Model No. 1 (ADM1) to simulate such a ZVI-based anaerobic reactor. Three new processes, i.e., electron release from ZVI corrosion, H2 formation from ZVI corrosion, and transformation of LBPs, were integrated into ADM1. The established model was calibrated and tested using the experimental data from one published study, and validated using the data from another work. A good relationship between the predicted and measured results indicates that the proposed model was appropriate to describe the performance of the ZVI-based anaerobic system. Our model could provide more precise strategies for the design, development, and application of anaerobic systems especially for treating various LBPs-containing wastewaters. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Thermophilic anaerobic co-digestion of cattle manure with agro-wastes and energy crops: comparison of pilot and full scale experiences.

    PubMed

    Cavinato, C; Fatone, F; Bolzonella, D; Pavan, P

    2010-01-01

    The paper deals with the benefits coming from the application of a proper process temperature (55 degrees C) instead of a 'reduced' thermophilic range (47 degrees C), that is often applied in European anaerobic co-digestion plants. The experimental work has pointed out that biogas production improve from 0.45 to 0.62 m(3)/kg VS operating at proper thermophilic conditions. Moreover, also methane content was higher: from 52% to 61%. A general improvement in digester behaviour was clear also considering the stability parameters comparison (pH, ammonia, VFA content). The second part of the study takes into account the economic aspects related to the capital cost of anaerobic digestion treatment with a 1 MW co-generation unit fro heat and power production (CHP). Moreover, the economic balance was also carried out considering the anaerobic supernatants treatment for nitrogen removal. The simulation showed how a pay-back-time of 2.5 yr and between 3 and 5 yr respectively could be determined when the two options of anaerobic digestion only and together with the application of a nitrogen removal process were considered.

  10. The ACTN3 R577X polymorphism is associated with muscle power in male Japanese athletes.

    PubMed

    Kikuchi, Naoki; Nakazato, Koichi; Min, Seok-ki; Ueda, Dai; Igawa, Shoji

    2014-07-01

    In this study, we investigated whether the ACTN3 R577X polymorphism is associated with muscular power in Japanese collegiate athletes by analyzing the mean and peak power results of a 30-second Wingate anaerobic test (WAnT) with respect to the ACTN3 R577X genotype in 253 Japanese athletes (144 men and 109 women). Each athlete performed a 30-second WAnT with a resistance equal to 7.5% of his or her body weight. Genotyping for the ACTN3 R577X (rs1815739) polymorphism was performed using the TaqMan approach. The ACTN3 R577X genotypes exhibited a Hardy-Weinberg equilibrium distribution in our population. The relative and absolute mean power results of the 30-second WAnT did not differ significantly among the genotypes. However, the relative peak power result of the WAnT was significantly higher in the R-allele-dominant model groups than in the XX group in male but not female athletes. These results suggest that the ACTN3 R allele is associated with the relative peak power during the WAnT in male Japanese collegiate athletes.

  11. Effects of self-selected dehydration and meaningful rehydration on anaerobic power and heart rate recovery of elite wrestlers.

    PubMed

    Cengiz, Asim

    2015-05-01

    [Purpose] This study aimed to verify the effects of self-directed weight loss on lower- and upper-body power, fatigue index, and heart rate recovery immediately before a meaningful competition (12 hours of recovery). In addition, this study tested the hypothesis that weight loss provides advantages in strength and power, as the relative power of the wrestlers is higher than that of opponents in the same weight class who do not reduce weight. [Subjects and Methods] Eleven well-trained wrestlers volunteered for the study. At baseline, their mean ± SD age, body mass, and height were 20.45 ± 2.69 years, 74.36 ± 9.22 kg, and 177 ± 5.71 cm, respectively. Repeated-measures one-way analysis of variance was performed to analyze differences. [Results] Rapid weight loss achieved by restriction of energy and fluid intake resulted in exercise-impaired decreases in peak power and increased fatigue index. Moreover, weight loss by dehydration negatively affected cardiovascular stability. [Conclusion] Most of the negative effects of rapid weight loss disappear after a 12-hour recovery period, and relative peak power increases after weight loss.

  12. Numerical simulation of mechanical mixing in high solid anaerobic digester.

    PubMed

    Yu, Liang; Ma, Jingwei; Chen, Shulin

    2011-01-01

    Computational fluid dynamics (CFD) was employed to study mixing performance in high solid anaerobic digester (HSAD) with A-310 impeller and helical ribbon. A mathematical model was constructed to assess flow fields. Good agreement of the model results with experimental data was obtained for the A-310 impeller. A systematic comparison for the interrelationship of power number, flow number and Reynolds number was simulated in a digester with less than 5% TS and 10% TS (total solids). The simulation results suggested a great potential for using the helical ribbon mixer in the mixing of high solids digester. The results also provided quantitative confirmation for minimum power consumption in HSAD and the effect of share rate on bio-structure. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Nutrition and Supplements for Elite Open-Weight Rowing.

    PubMed

    Boegman, Susan; Dziedzic, Christine E

    2016-01-01

    Competitive rowing events are raced over 2,000 m requiring athletes to have highly developed aerobic and anaerobic systems. Elite rowers therefore undertake training sessions focused on lactate tolerance, strength and power as well as aerobic and anaerobic capacity development, that can amount to a 24-h training week. The training stimuli and consequent metabolic demands of each session in a rowing training program differ depending on type, length, and intensity. Nutrition guidelines for endurance- and power-based sports should be drawn upon; however, individualized and flexible nutrition plans are critical to successfully meet the daily, weekly, and cyclic nutrient requirements of a rower. This review will provide an overview of key nutritional strategies to optimize training and enhance adaptation, and briefly discuss supplement strategies that may support health and enhance performance in elite rowing.

  14. Study of thermal pre-treatment on anaerobic digestion of slaughterhouse waste by TGA-MS and FTIR spectroscopy.

    PubMed

    Rodríguez-Abalde, Ángela; Gómez, Xiomar; Blanco, Daniel; Cuetos, María José; Fernández, Belén; Flotats, Xavier

    2013-12-01

    Thermogravimetric analysis coupled to mass spectrometry (TGA-MS) and Fourier-transform infrared spectroscopy (FTIR) were used to describe the effect of pasteurization as a hygienic pre-treatment of animal by-products over biogas production. Piggery and poultry meat wastes were used as substrates for assessing the anaerobic digestion under batch conditions at mesophilic range. Poultry waste was characterized by high protein and carbohydrate content, while piggery waste presented a major fraction of fat and lower carbohydrate content. Results from anaerobic digestion tests showed a lower methane yield for the pre-treated poultry sample. TGA-MS and FTIR spectroscopy allowed the qualitative identification of recalcitrant nitrogen-containing compounds in the pre-treated poultry sample, produced by Maillard reactions. In the case of piggery waste, the recalcitrant compounds were not detected and its biodegradability test reported higher methane yield and production rates. TGA-MS and FTIR spectroscopy were demonstrated to be useful tools for explaining results obtained by anaerobic biodegradability test and in describing the presence of inhibitory problems.

  15. Releasing characteristics and fate of heavy metals from phytoremediation crop residues during anaerobic digestion.

    PubMed

    Lee, Jongkeun; Park, Ki Young; Cho, Jinwoo; Kim, Jae Young

    2018-01-01

    In this study, lab-scale batch tests were conducted to investigate releasing characteristics of heavy metals according to degradation of heavy metal containing biomass. The fate of heavy metals after released from biomass was also determined through adsorption tests and Visual MINTEQ simulation. According to the anaerobic batch test results as well as volatile solids and carbon balance analyses, maximum of 60% by wt. of biomass was degraded. During the anaerobic biodegradation, among Cd, Cu, Ni, Pb, and Zn, only Cu and Zn were observed in soluble form (approximately 40% by wt. of input mass). The discrepancy between degradation ratio of biomass and ratio of released heavy metals mass from biomass was observed. It seems that this discordance was caused by the fate (i.e., precipitated with sulfur/hydroxide or adsorbed onto sorbents) of each heavy metal types in solution after being released from biomass. Thus, releasing characteristics and fate of heavy metal should be considered carefully to predict stability of anaerobic digestion process for heavy metal-containing biomass. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Fungal fermentation on anaerobic digestate for lipid-based biofuel production.

    PubMed

    Zhong, Yuan; Liu, Zhiguo; Isaguirre, Christine; Liu, Yan; Liao, Wei

    2016-01-01

    Anaerobic digestate is the effluent from anaerobic digestion of organic wastes. It contains a significant amount of nutrients and lignocellulosic materials, even though anaerobic digestion consumed a large portion of organic matters in the wastes. Utilizing the nutrients and lignocellulosic materials in the digestate is critical to significantly improve efficiency of anaerobic digestion technology and generate value-added chemical and fuel products from the organic wastes. Therefore, this study focused on developing an integrated process that uses biogas energy to power fungal fermentation and converts remaining carbon sources, nutrients, and water in the digestate into biofuel precursor-lipid. The process contains two unit operations of anaerobic digestion and digestate utilization. The digestate utilization includes alkali treatment of the mixture feed of solid and liquid digestates, enzymatic hydrolysis for mono-sugar release, overliming detoxification, and fungal fermentation for lipid accumulation. The experimental results conclude that 5 h and 30 °C were the preferred conditions for the overliming detoxification regarding lipid accumulation of the following fungal cultivation. The repeated-batch fungal fermentation enhanced lipid accumulation, which led to a final lipid concentration of 3.16 g/L on the digestate with 10% dry matter. The mass and energy balance analysis further indicates that the digestate had enough water for the process uses and the biogas energy was able to balance the needs of individual unit operations. A fresh-water-free and energy-positive process of lipid production from anaerobic digestate was achieved by integrating anaerobic digestion and fungal fermentation. The integration addresses the issues that both biofuel industry and waste management encounter-high water and energy demand of biofuel precursor production and few digestate utilization approaches of organic waste treatment.

  17. Multi-centre evaluation of mass spectrometric identification of anaerobic bacteria using the VITEK® MS system.

    PubMed

    Garner, O; Mochon, A; Branda, J; Burnham, C-A; Bythrow, M; Ferraro, M; Ginocchio, C; Jennemann, R; Manji, R; Procop, G W; Richter, S; Rychert, J; Sercia, L; Westblade, L; Lewinski, M

    2014-04-01

    Accurate and timely identification of anaerobic bacteria is critical to successful treatment. Classic phenotypic methods for identification require long turnaround times and can exhibit poor species level identification. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an identification method that can provide rapid identification of anaerobes. We present a multi-centre study assessing the clinical performance of the VITEK(®) MS in the identification of anaerobic bacteria. Five different test sites analysed a collection of 651 unique anaerobic isolates comprising 11 different genera. Multiple species were included for several of the genera. Briefly, anaerobic isolates were applied directly to a well of a target plate. Matrix solution (α-cyano-4-hydroxycinnamic acid) was added and allowed to dry. Mass spectra results were generated with the VITEK(®) MS, and the comparative spectral analysis and organism identification were determined using the VITEK(®) MS database 2.0. Results were confirmed by 16S rRNA gene sequencing. Of the 651 isolates analysed, 91.2% (594/651) exhibited the correct species identification. An additional eight isolates were correctly identified to genus level, raising the rate of identification to 92.5%. Genus-level identification consisted of Actinomyces, Bacteroides and Prevotella species. Fusobacterium nucleatum, Actinomyces neuii and Bacteroides uniformis were notable for an increased percentage of no-identification results compared with the other anaerobes tested. VITEK(®) MS identification of clinically relevant anaerobes is highly accurate and represents a dramatic improvement over other phenotypic methods in accuracy and turnaround time. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  18. Estimation of the anaerobic threshold from heart rate variability in an incremental swimming test.

    PubMed

    Di Michele, Rocco; Gatta, Giorgio; Di Leo, Antonino; Cortesi, Matteo; Andina, Francesca; Tam, Enrico; Da Boit, Mariasole; Merni, Franco

    2012-11-01

    This study aimed to evaluate, in swimming, the agreement between the anaerobic threshold (AT) as determined from the analysis of blood lactate concentration ([La]) and from a new method based on the heart rate (HR) variability (HRV). Fourteen high-level swimmers completed an incremental 7 × 200-m front crawl test, during which the HRV was measured continuously and [La] was collected after each step. To individuate the AT, the trends of the high-frequency HRV spectral power (HFPOW) and of the fraction of HFPOW relative to the respiratory sinus arrhythmia (HFPOW-RSA) were analyzed. In all the subjects, an abrupt increase of both HFPOW and HFPOW-RSA was observed and associated with the AT. The AT parameters determined, respectively, from [La] and HFPOW-RSA were similar (p > 0.05) and highly correlated (HR: 182.0 ± 8.1 vs. 181.1 ± 8.2 b·min, r = 0.93, 95% limits of agreement [LoA]: -6.7 to 4.9 b·min; velocity: 1.47 ± 0.11 vs. 1.47 ± 0.11 m·s, r = 0.98, 95% LoA: -0.05 to 0.05 m·s). Instead, the AT HR and velocity obtained from HFPOW (179.2 ± 8.4 b·min; 1.45 ± 0.11 m·s) were correlated to the corresponding parameters determined from [La] (HR: r = 0.84; velocity: r = 0.94) but underestimated them slightly (95% LoA: -11.9 to 6.3 b·min and -0.11 to 0.05 m·s). These results demonstrate that the AT can be assessed from the HRV in swimming, providing an important testing tool for coaches. Furthermore, using the actual respiratory spectral component, rather than the total HF spectral power, allows us to obtain a more accurate estimate of AT parameters.

  19. An active principle of Nigella sativa L., thymoquinone, showing significant antimicrobial activity against anaerobic bacteria.

    PubMed

    Randhawa, Mohammad Akram; Alenazy, Awwad Khalaf; Alrowaili, Majed Gorayan; Basha, Jamith

    2017-01-01

    Thymoquinone (TQ) is the major active principle of Nigella sativa seed (black seed) and is known to control many fungi, bacteria, and some viruses. However, the activity of TQ against anaerobic bacteria is not well demonstrated. Anaerobic bacteria can cause severe infections, including diarrhea, aspiration pneumonia, and brain abscess, particularly in immunodeficient individuals. The present study aimed to investigate the in vitro antimicrobial activity of TQ against some anaerobic pathogens in comparison to metronidazole. Standard, ATCC, strains of four anaerobic bacteria ( Clostridium difficile , Clostridium perfringens , Bacteroides fragilis , and Bacteroides thetaiotaomicron ), were initially isolated on special Brucella agar base (with hemin and vitamin K). Then, minimum inhibitory concentrations (MICs) of TQ and metronidazole were determined against these anaerobes when grown in Brucella agar, using serial agar dilution method according to the recommended guidelines for anaerobic organisms instructed by the Clinical and Laboratory Standards Institute. TQ showed a significant antimicrobial activity against anaerobic bacteria although much weaker than metronidazole. MICs of TQ and metronidazole against various anaerobic human pathogens tested were found to be between 10-160 mg/L and 0.19-6.25 mg/L, respectively. TQ controlled the anaerobic human pathogenic bacteria, which supports the use of N. sativa in the treatment of diarrhea in folk medicine. Further investigations are in need for determination of the synergistic effect of TQ in combination with metronidazole and the activity of derivatives of TQ against anaerobic infections.

  20. An integrated approach to energy recovery from biomass and waste: Anaerobic digestion-gasification-water treatment.

    PubMed

    Milani, M; Montorsi, L; Stefani, M

    2014-07-01

    The article investigates the performance of an integrated system for the energy recovery from biomass and waste based on anaerobic digestion, gasification and water treatment. In the proposed system, the organic fraction of waste of the digestible biomass is fed into an anaerobic digester, while a part of the combustible fraction of the municipal solid waste is gasified. Thus, the obtained biogas and syngas are used as a fuel for running a cogeneration system based on an internal combustion engine to produce electric and thermal power. The waste water produced by the integrated plant is recovered by means of both forward and inverse osmosis. The different processes, as well as the main components of the system, are modelled by means of a lumped and distributed parameter approach and the main outputs of the integrated plant such as the electric and thermal power and the amount of purified water are calculated. Finally, the implementation of the proposed system is evaluated for urban areas with a different number of inhabitants and the relating performance is estimated in terms of the main outputs of the system. © The Author(s) 2014.

  1. Effects of mini trampoline exercise on male gymnasts' physiological parameters: a pilot study.

    PubMed

    Karakollukçu, M; Aslan, C S; Paoli, A; Bianco, A; Sahin, F N

    2015-01-01

    There are limited studies that indicate the effects of trampoline exercise on strength and other physiological parameters. This study aims to determine whether twelve weeks of trampoline exercise would have any effects on the physical and physiological parameters of male gymnasts. A number of 20 intercollegiate competitive male gymnasts (as experimental group) and 20 non-athlete male (as control group) participated voluntarily. Their anthropometric characteristics and the anaerobic power were measured and their back strength, vertical jump, standing long jump and 20 meter sprint performances were measured. As a result; whereas 12 weeks of trampoline exercise improved standing long jump (before 242.35±3.40 cm; after 251.70±2.95 cm) and also vertical jump, 20 meter sprint speed and anaerobic power of subjects. We did not observe significant changes on back strength performances (before 148.32±5.73 kg; after 148.10±5.71). The trampoline exercise protocol improved significantly speed, jump and anaerobic performances of the experimental group, while did not induced any changes on back strength performances. More studies are necessary to confirm the interesting results coming from this pilot intervention.

  2. Aerobic and Anaerobic Swimming Force Evaluation in One Single Test Session for Young Swimmers.

    PubMed

    de Barros Sousa, Filipe Antônio; Rodrigues, Natalia Almeida; Messias, Leonardo Henrique Dalcheco; Queiroz, Jair Borges; Manchado-Gobatto, Fulvia Barros; Gobatto, Claudio Alexandre

    2017-05-01

    This study aims to propose and validate the tethered swimming lactate minimum test (TSLacmin) estimating aerobic and anaerobic capacity in one single test session, using force as measurement parameter. 6 male and 6 female young swimmers (age=15.7±1.1 years; height=173.3±9.5 cm; weight=66.1±9.5 kg) performed 4 sessions comprising i) an all-out 30 s test and incremental test (TSLacmin); ii) 30 min of tethered swimming at constant intensity (2 sessions); iii) free-swimming time trials used to calculate critical velocity. Tethered swimming sessions used an acquisition system enabling maximum (Fmax) and mean (Fmean) force measurement and intensity variation. The tethered all-out test lasting 30 s resulted in hyperlactatemia of 7.9±2.0 mmol·l -1 . TSLacmin presented a 100% success applicability rate, which is equivalent to aerobic capacity in 75% of cases. TSLacmin intensity was 37.7±7.3 N, while maximum force in the all-out test was 105±27 N. Aerobic and anaerobic TSLacmin parameters were significantly related to free-swimming performance (r=-0.67 for 100 m and r=-0.80 for 200 m) and critical velocity (r=0.80). TSLacmin estimates aerobic capacity in most cases, and both aerobic and anaerobic force parameters are well related to critical velocity and free swimming performance. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Modified Anaerobic Digestion Model No.1 for dry and semi-dry anaerobic digestion of solid organic waste.

    PubMed

    Liotta, Flavia; Chatellier, Patrice; Esposito, Giovanni; Fabbricino, Massimiliano; Frunzo, Luigi; van Hullebusch, Eric D; Lens, Piet N L; Pirozzi, Francesco

    2015-01-01

    The role of total solids (TS) content in anaerobic digestion of selected complex organic matter, e.g. rice straw and food waste, was investigated. A range of TS from wet (4.5%) to dry (23%) was evaluated. A modified version of the Anaerobic Digestion Model No.1 for a complex organic substrate is proposed to take into account the effect of the TS content on anaerobic digestion. A linear function that correlates the kinetic constants of three specific processes (i.e. disintegration, acetate and propionate up-take) was included in the model. Results of biomethanation and volatile fatty acids production tests were used to calibrate the proposed model. Model simulations showed a good agreement between numerical and observed data.

  4. Evaluation of the RapID-ANA system for identification of anaerobic bacteria of veterinary origin.

    PubMed

    Adney, W S; Jones, R L

    1985-12-01

    This study evaluated the ability of the RapID-ANA system (Innovative Diagnostic Systems, Inc., Atlanta, Ga.) to accurately identify a spectrum of freshly isolated veterinary anaerobes. A total of 183 isolates were tested and included 7 Actinomyces spp., 53 Bacteroides spp., 32 Clostridium spp., 2 Eubacterium spp., 65 Fusobacterium spp., 1 Peptococcus spp., 22 Peptostreptococcus spp., and 1 Propionibacterium spp. All isolates were initially identified by conventional biochemical testing and gas-liquid chromatography of short-chain fatty acid metabolites. Additional tests were performed as required by the RapID-ANA system. Of these isolates, 81.4% were correctly identified to the genus level, including 59.6% to the species level, 14.2% were incorrectly identified at the genus level, and 4.4% were not identified. Initially, 20.2% of the strains were not identified because the microcodes were not in the code book. The majority of the incorrect identifications were caused by the misidentification of Fusobacterium spp. as Bacteroides spp. Errors also occurred when veterinary anaerobes not included in the data base were assigned an identification from the existing data base. The RapID-ANA system appears to be a promising new method for rapid identification of veterinary anaerobes; however, further evaluation with an extended data base is needed before the system can accurately identify all clinically significant anaerobes.

  5. Lower Wingate Test Power Outcomes From "All-Out" Pretest Pedaling Cadence Compared With Moderate Cadence.

    PubMed

    Lunn, William R; Zenoni, Maria A; Crandall, Ian H; Dress, Ashley E; Berglund, Michelle L

    2015-08-01

    The aim of the present study was to determine the effect of different pretest pedaling cadences on power outcomes obtained during the Wingate Anaerobic Test (WAnT). Vigorously exercising adult men (n = 14, 24.9 ± 1.2 years) and women (n = 14, 20.4 ± 0.6 years) participated in a randomized crossover study during which they performed the 30-second WAnT on a mechanically braked cycle ergometer (0.075 kg·kg(-1) body weight) under 2 conditions. Participants pedaled maximally with an unloaded flywheel during 5 seconds before resistance was applied and the test began (FAST). In another trial, participants maintained a moderate cadence (80 revolutions per minute [rpm]) during 5 seconds before the test began (MOD). All other components of the WAnT were identical. Peak power (PP), mean power (MP), minimum power (MinP), fatigue index (%FAT), and maximum cadence during test were recorded. Comparisons were made using a 2 × 2 factorial repeated-measures analysis of variance. Regardless of gender, the FAST condition resulted in 22.2% lower PP (612.6 ± 33.0 W vs. 788.3 ± 43.5 W), 13.3% lower MP (448.4 ± 22.2 W vs. 517.2 ± 26.4 W), 11.7% lower MinP (280.9 ± 14.8 W vs. 318.3 ± 17.2 W), and 9.0% lower %FAT (53.5 ± 1.3% vs. 58.8 ± 1.5%) than MOD condition (p < 0.01; mean ± SD). Similar outcomes were observed within gender. The authors conclude that practitioners of the WAnT should instruct participants to maintain a moderate pedal cadence (∼80 rpm) during 5 seconds before the test commences to avoid bias from software sampling and peripheral fatigue. Standardizing the pretest pedal cadence will be important to exercise testing professionals who compare data with norms or generate norms for specific populations.

  6. Evaluation of the new Vitek 2 ANC card for identification of medically relevant anaerobic bacteria.

    PubMed

    Mory, Francine; Alauzet, Corentine; Matuszeswski, Céline; Riegel, Philippe; Lozniewski, Alain

    2009-06-01

    Of 261 anaerobic clinical isolates tested with the new Vitek 2 ANC card, 257 (98.5%) were correctly identified at the genus level. Among the 251 strains for which identification at the species level is possible with regard to the ANC database, 217 (86.5%) were correctly identified at the species level. Two strains (0.8%) were not identified, and eight were misidentified (3.1%). Of the 21 strains (8.1%) with low-level discrimination results, 14 were correctly identified at the species level by using the recommended additional tests. This system is a satisfactory new automated tool for the rapid identification of most anaerobic bacteria isolated in clinical laboratories.

  7. The Physiological Profile of Junior Soccer Players at SSBB Surabaya Bhakti

    NASA Astrophysics Data System (ADS)

    Nashirudin, M.; Kusnanik, N. W.

    2018-01-01

    Soccer players are required to have good physical fitness in order to achieve optimum accomplishment; physical fitness stands as the foundation of technical and tactical proficiency as well as the mental maturity during the matches. The purpose of this study was to identify the physiological profile of junior soccer players of SSB Surabaya Bhakti age 16-17. The research was conducted at 20 junior soccer players. This research was quantitative with descriptive analysis. Data were collected by testing of physiological (anaerobic power and capacity including explosive leg power, speed, agility; aerobic capacity: cardiovascular endurance). Data was analyzed using percentage. The result showed that the percentage of explosive leg power of junior soccer players were 30% (good category), speed was 85% (average category), right agility was 90% (average category), left agility was 75% (average category). On the other hand, the aerobic power and capacity of the junior soccer players in this study was 50% (average category). The conclusion of this research is that the physiological profile of junior soccer players at SSB Surabaya Bhakti age 16-17 was majority in average category.

  8. The relationship between body composition and preseason performance tests of collegiate male lacrosse players.

    PubMed

    Collins, Sean M; Silberlicht, Max; Perzinski, Chris; Smith, Stephen P; Davidson, Patrick W

    2014-09-01

    Numerous studies have examined the effects that body composition has on performance in football, soccer, and ice hockey; yet, there are no similar studies examining this relationship in men's lacrosse. The purpose of the study was to examine the physiological profiles and the relationship between body composition and performance in aerobic and anaerobic tests. Fifty-four (19.63 ± 1.21 years; 178.53 ± 6.17 cm; 81.66 ± 14.96 kg) Division III intercollegiate athletes participated. Performance tests, including a 1 repetition maximum power clean (PC), body weight (lbs), bench press repetitions, parallel bar triceps dips to fatigue (DR), two 300-yard shuttles, and a 1-mile run (MT), were completed after the completion of fall preseason practices. Body composition was estimated using air-displacement plethysmography. Correlation coefficients determined relationships between percent body fat (%BF), fat-free mass (FFM), and testing variables. Increased %BF was negatively correlated to DR (r = -0.36, p = 0.01) whereas positively correlated to each 300-yard shuttle time (T1 and T2), total 300-yard shuttle time (TT), and MT (r = 0.64, p = 0.00; r = 0.68, p = 0.00; r = 0.69, p = 0.00; and r = 0.44, p = 0.00, respectively). Increased FFM was positively correlated with PC (r = 0.58, p = 0.00) yet not correlated (p ≥ 0.05) with other variables. Results indicated that increased %BF might be a detriment to the repetitive anaerobic performance and aerobic capacity vital to on-field lacrosse performance. Body composition also demonstrated a significant relationship to moving internal vs. external resistances.

  9. Ischemic preconditioning of the muscle improves maximal exercise performance but not maximal oxygen uptake in humans.

    PubMed

    Crisafulli, Antonio; Tangianu, Flavio; Tocco, Filippo; Concu, Alberto; Mameli, Ombretta; Mulliri, Gabriele; Caria, Marcello A

    2011-08-01

    Brief episodes of nonlethal ischemia, commonly known as "ischemic preconditioning" (IP), are protective against cell injury induced by infarction. Moreover, muscle IP has been found capable of improving exercise performance. The aim of the study was the comparison of standard exercise performances carried out in normal conditions with those carried out following IP, achieved by brief muscle ischemia at rest (RIP) and after exercise (EIP). Seventeen physically active, healthy male subjects performed three incremental, randomly assigned maximal exercise tests on a cycle ergometer up to exhaustion. One was the reference (REF) test, whereas the others were performed after the RIP and EIP sessions. Total exercise time (TET), total work (TW), and maximal power output (W(max)), oxygen uptake (VO(2max)), and pulmonary ventilation (VE(max)) were assessed. Furthermore, impedance cardiography was used to measure maximal heart rate (HR(max)), stroke volume (SV(max)), and cardiac output (CO(max)). A subgroup of volunteers (n = 10) performed all-out tests to assess their anaerobic capacity. We found that both RIP and EIP protocols increased in a similar fashion TET, TW, W(max), VE(max), and HR(max) with respect to the REF test. In particular, W(max) increased by ∼ 4% in both preconditioning procedures. However, preconditioning sessions failed to increase traditionally measured variables such as VO(2max), SV(max,) CO(max), and anaerobic capacity(.) It was concluded that muscle IP improves performance without any difference between RIP and EIP procedures. The mechanism of this effect could be related to changes in fatigue perception.

  10. Denitrifying sulfur conversion-associated EBPR: The effect of pH on anaerobic metabolism and performance.

    PubMed

    Guo, Gang; Wu, Di; Hao, Tianwei; Mackey, Hamish Robert; Wei, Li; Chen, Guanghao

    2017-10-15

    The performance of the denitrifying sulfur conversion-associated enhanced biological phosphorus removal (DS-EBPR) process tends to be unstable and requires further study and development. This in turn requires extensive study of the anaerobic metabolism in terms of its stoichiometry and kinetics. This study evaluates the corresponding responses of DS-EBPR to pH, as it significantly influences both stoichiometry and biochemical kinetics. The impacts of five representative pH values ranging between 6.5 and 8.5 on the anaerobic metabolism were investigated, followed by identification of the optimal pH for performance optimization. A mature DS-EBPR sludge was used in the study, enriched with approximately 30% sulfate-reducing bacteria (SRB) and 33% sulfide-oxidizing bacteria (SOB). Through a series of batch tests, the optimal pH range was determined as 7.0-7.5. In this pH range, the anaerobic stoichiometry of phosphorus released/volatile fatty acid (VFA) uptake ratio, sulfate reduction, and internal polymer production (including poly-β-hydroxyalkanoates and polysulfide and/or elemental sulfur) all increased along with the anaerobic kinetics of the VFA uptake ratio. Consequently, phosphorus removal was maximized at this pH range (≥95% vs. 84-93% at other pH values), as was sulfur conversion (16 mg S/L vs. 10-13 mg S/L). This pH range therefore favors the activity and synergy of the key functional bacteria (i.e. SRB and SOB). Anaerobic maintenance tests showed these bacteria required 38-61% less energy for maintenance than that reported for GAOs regardless of pH changes, improving their ability to cope with anaerobic starvation. Adversely, both bacteria showed much lower VFA uptake rates than that of GAOs at all tested pH values (0.03-0.06 vs. 0.2-0.24 mol-C/C-mol biomass/h), possibly revealing the primary cause of frequent instability in the DS-EBPR process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Association Between Anaerobic Metabolic Demands During Simulated Brazilian Jiu-Jitsu Combat and Specific Jiu-Jitsu Anaerobic Performance Test.

    PubMed

    Villar, Rodrigo; Gillis, Jason; Santana, Givanildo; Pinheiro, Daniel S; Almeida, André L R A

    2018-02-01

    Villar, R, Gillis, J, Santana, G, Pinheiro, DS, and Almeida, ALRA. Association between anaerobic metabolic demands during simulated Brazilian jiu-jitsu combat and specific jiu-jitsu anaerobic performance test. J Strength Cond Res 32(2): 432-440, 2018-The aims of this study were to design a specific Jiu-Jitsu anaerobic performance test (JJAPT) and investigate the relationship between blood lactate ([La]), heart rate (HR), and rating of perceived exertion (RPE) during simulated Brazilian Jiu-Jitsu combat (SBJJC) and JJAPT. Nine male elite Brazilian medium heavy weight athletes performed a 10-minute SBJJC and JJAPT that required performance of a common BJJ technique for 5 consecutive bouts of 1-minute with 45-second rest between bouts. [La] was measured by a lactate analyzer, HR by an HR monitor, and RPE using Borg's scale, and the number of repetitions of butterfly lifts (NBL) was recorded. During JJAPT, NBL decreased in the fourth and fifth bouts (p ≤ 0.05) with increases in [La], HR, and RPE (p ≤ 0.05), indicating that the JJAPT measured anaerobic performance. [La] during SBJJC was not different than [La] at the third and fourth bouts, but was significantly different than the fifth bout (p ≤ 0.05). [La] showed strong correlation between SBJJC and JJAPT for the third (r = 0.80, p ≤ 0.05), fourth (r = 0.83, p ≤ 0.05), and fifth (r = 0.82, p ≤ 0.05) bouts, but not between the HR and RPE. The JJAPT with 4 bouts presented the best combination of stimulus and highest correlation with SBJJC, supporting its use to assess anaerobic performance of BJJ athletes. These data will aid coaches and athletes to better understand the demands of their sport and may help to monitor adaptation in sport-specific performance across periodized training plans.

  12. Biogas production from anaerobic digestion of food waste and relevant air quality implications.

    PubMed

    Kuo, Jeff; Dow, Jason

    2017-09-01

    Biopower can diversify energy supply and improve energy resiliency. Increases in biopower production from sustainable biomass can provide many economic and environmental benefits. For example, increasing biogas production through anaerobic digestion of food waste would increase the use of renewable fuels throughout California and add to its renewables portfolio. Although a biopower project will produce renewable energy, the process of producing bioenergy should harmonize with the goal of protecting public health. Meeting air emission requirements is paramount to the successful implementation of any biopower project. A case study was conducted by collecting field data from a wastewater treatment plant that employs anaerobic codigestion of fats, oils, and grease (FOG), food waste, and wastewater sludge, and also uses an internal combustion (IC) engine to generate biopower using the biogas. This research project generated scientific information on (a) quality and quantity of biogas from anaerobic codigestion of food waste and municipal wastewater sludge, (b) levels of contaminants in raw biogas that may affect beneficial uses of the biogas, (c) removal of the contaminants by the biogas conditioning systems, (d) emissions of NO x , SO 2 , CO, CO 2 , and methane, and (e) types and levels of air toxics present in the exhausts of the IC engine fueled by the biogas. The information is valuable to those who consider similar operations (i.e., co-digestion of food waste with municipal wastewater sludge and power generation using the produced biogas) and to support rulemaking decisions with regards to air quality issues for such applications. Full-scale operation of anaerobic codigestion of food waste with municipal sludge is viable, but it is still new. There is a lack of readily available scientific information on the quality of raw biogas, as well as on potential emissions from power generation using this biogas. This research developed scientific information with regard to quality and quantity of biogas from anaerobic co-digestion of food waste and municipal wastewater sludge, as well as impacts on air quality from biopower generation using this biogas. The need and performance of conditioning/pretreatment systems for biopower generation were also assessed.

  13. Exercise may cause myocardial ischemia at the anaerobic threshold in cardiac rehabilitation programs.

    PubMed

    Fuchs, A R C N; Meneghelo, R S; Stefanini, E; De Paola, A V; Smanio, P E P; Mastrocolla, L E; Ferraz, A S; Buglia, S; Piegas, L S; Carvalho, A A C

    2009-03-01

    Myocardial ischemia may occur during an exercise session in cardiac rehabilitation programs. However, it has not been established whether it is elicited when exercise prescription is based on heart rate corresponding to the anaerobic threshold as measured by cardiopulmonary exercise testing. Our objective was to determine the incidence of myocardial ischemia in cardiac rehabilitation programs according to myocardial perfusion SPECT in exercise programs based on the anaerobic threshold. Thirty-nine patients (35 men and 4 women) diagnosed with coronary artery disease by coronary angiography and stress technetium-99m-sestamibi gated SPECT associated with a baseline cardiopulmonary exercise test were assessed. Ages ranged from 45 to 75 years. A second cardiopulmonary exercise test determined training intensity at the anaerobic threshold. Repeat gated-SPECT was obtained after a third cardiopulmonary exercise test at the prescribed workload and heart rate. Myocardial perfusion images were analyzed using a score system of 6.4 at rest, 13.9 at peak stress, and 10.7 during the prescribed exercise (P < 0.05). The presence of myocardial ischemia during exercise was defined as a difference > or = 2 between the summed stress score and summed rest score. Accordingly, 25 (64%) patients were classified as ischemic and 14 (36%) as nonischemic. MIBI-SPECT showed myocardial ischemia during exercise within the anaerobic threshold. The 64% prevalence of ischemia observed in the study should not be looked on as representative of the whole population of patients undergoing exercise programs. Changes in patient care and exercise programs were implemented as a result of our finding of ischemia during the prescribed exercise.

  14. Antimicrobial activity of four root canal sealers against endodontic pathogens.

    PubMed

    Lai, C C; Huang, F M; Yang, H W; Chan, Y; Huang, M S; Chou, M Y; Chang, Y C

    2001-12-01

    The antibacterial effects of various types of widely used endodontic sealers have not been compared systematically on facultative or obligate anaerobic endodontic pathogens. The aim of this study was to evaluate the antimicrobial properties of four commonly used endodontic sealers: two epoxy-resin-based sealers (AH26, AH plus), one zinc-oxide eugenol-based sealer (N2), and one calcium hydroxide-based sealer (Sealapex). The testing microbes were four facultative anaerobic species (Streptococcus mutans, Streptococcus sanguis, Escherichia coli, and Staphylococcus aureus) and four obligate anaerobic species (Porphyromonas gingivalis, Porphyromonas endodontalis, Fusobacterium nucleatum, and Prevotella intermedia). The freshly mixed sealers were placed into the prepared wells of agar plates inoculated with the test microorganisms. After varying periods of incubation (2 days for facultative anaerobic species and 7 days for obligate anaerobic species), the zones of growth inhibition were observed and measured. All the sealers were distinctly different from each other in their antimicrobial activity. The sealers showed different inhibitory effects depending on the types and bacterial strains. N2 containing formaldehyde and eugenol proved to be the most effective against the microorganisms. The extreme antimicrobial potency of this root canal sealer must be weighted against its pronounced tissue toxic effect.

  15. Musculoskeletal, biomechanical, and physiological gender differences in the US military.

    PubMed

    Allison, Katelyn F; Keenan, Karen A; Sell, Timothy C; Abt, John P; Nagai, Takashi; Deluzio, Jennifer; McGrail, Mark; Lephart, Scott M

    2015-01-01

    The repeal of the Direct Ground Combat Assignment Rule has renewed focus on examining performance capabilities of female military personnel and their ability to occupy previously restricted military occupational specialties. Previous research has revealed female Soldiers suffer a greater proportion of musculoskeletal injuries compared to males, including a significantly higher proportion of lower extremity, knee, and overuse injuries. Potential differences may also exist in musculoskeletal, biomechanical, and physiological characteristics between male and female Soldiers requiring implementation of gender-specific training in order to mitigate injury risk and enhance performance. To examine differences in musculoskeletal, biomechanical, and physiological characteristics in male and female Soldiers. A total of 406 101st Airborne Division (Air Assault) Soldiers (348 male; 58 female) participated. Subjects underwent testing for flexibility, isokinetic and isometric strength (percent body weight), single-leg balance, lower body biomechanics during a stop jump and drop landing, body composition, anaerobic power/capacity, and aerobic capacity. Independent t tests assessed between-group comparisons. Women demonstrated significantly greater flexibility (P<.01-P<.001) and better balance (P≤.001) than men. Men demonstrated significantly greater strength (P≤.001), aerobic capacity (47.5±7.6 vs 40.3±5.4 ml/kg/min, P<.001), anaerobic power (13.3±2.1 vs 9.5±1.7 W/kg, P<.001), and anaerobic capacity (7.8±1.0 vs 6.1±0.8 W/kg, P<.001) and lower body fat (20.1±7.5 vs 26.7±5.7 (%BF), P<.001). Women demonstrated significantly greater hip flexion and knee valgus at initial contact during both the stop jump and drop landing tasks and greater knee flexion at initial contact during the drop landing task (P<.05-P<.001). Gender differences exist in biomechanical, musculoskeletal, and physiological characteristics. Sex-specific interventions may aid in improving such characteristics to optimize physical readiness and decrease the injury risk during gender-neutral training, and decreasing between-sex variability in performance characteristics may result in enhanced overall unit readiness. Identification of sex-specific differences in injury patterns and characteristics should facilitate adjustments in training in order for both sexes to meet the gender-neutral occupational demands for physically demanding military occupational specialties.

  16. The effect of pre-test carbohydrate ingestion on the anaerobic threshold, as determined by the lactate-minimum test.

    PubMed

    Rotstein, Arie; Dotan, Raffy; Zigel, Levana; Greenberg, Tally; Benyamini, Yael; Falk, Bareket

    2007-12-01

    The purpose of this study was to investigate the effect of pre-test carbohydrate (CHO) ingestion on anaerobic-threshold assessment using the lactate-minimum test (LMT). Fifteen competitive male distance runners capable of running 10 km in 33.5-43 min were used as subjects. LMT was performed following CHO (2x300 mL, 7% solution) or comparable placebo (Pl) ingestion, in a double-blind, randomized order. The LMT consisted of two high-intensity 1 min treadmill runs (17-21 km.h(-1)), followed by an 8 min recovery period. Subsequently, subjects performed 5 min running stages, incremented by 0.6 km.h(-1) and separated by 1 min blood-sampling intervals. Tests were terminated after 3 consecutive increases in blood-lactate concentration ([La]) had been observed. Finger-tip capillary blood was sampled for [La] and blood-glucose determination 30 min before the test's onset, during the recovery phase following the 2 high-intensity runs, and following each of the subsequent 5 min stages. Heart rate (HR) and rating of perceived exertion (RPE) were recorded after each stage. The lactate-minimum speed (LMS) was determined from the individual [La]-velocity plots and was considered reflective of the anaerobic threshold. Pre-test CHO ingestion had no effect on LMS (13.19+/-1.12 km.h(-1) vs. 13.17+/-1.08 km.h(-1) in CHO and Pl, respectively), nor on [La] and glucose concentration at that speed, or on HR and RPE responses. Pre-test CHO ingestion therefore does not affect LMS or the LMT-estimated anaerobic threshold.

  17. Retesting The Validity Of A Specific Field Test For Judo Training

    PubMed Central

    Santos, Luis; González, Vicente; Iscar, Marta; Brime, Juan I.; Fernández-Río, Javier; Rodríguez, Blanca; Montoliu, Mª Ángeles

    2011-01-01

    The main goal of this research project was to retest the validity of a specifically designed judo field test (Santos Test) in a different group of judokas. Eight (n=8) national-level male judokas underwent laboratory and field testing. The mean data (mean +/− SD) obtained in the laboratory tests was: HRmax: 200 ± 4.0 beats × min−1, VO2 max: 52.8 ± 7.9 ± ml × kg−1 × min−1, lactate max: 12 ± 2.5 mmol × l−1, HR at the anaerobic threshold: 174.2 ± 9.4 beats × min−1, percentage of maximum heart rate at which the anaerobic threshold appears: 87 ± 3.6 %, lactate threshold: 4.0 ± 0.2 mmol × l−1, and RPE: 17.2 ± 1.0. The mean data obtained in the field test (Santos) was: HRmax: 201.3 ± 4.1 beats × min−1, VO2 max: 55.6 ± 5.8 ml × kg−1 × min−1, lactate max: 15.6 ± 2.8 mmol × l−1, HR at the anaerobic threshold: 173.2 ± 4.3 beats × min−1, percentage of maximum heart rate at which the anaerobic threshold appears: 86 ± 2.5 %, lactate threshold: 4.0 ± 0.2 mmol × l−1, and RPE: 16.7 ± 1.0. There were no significant differences between the data obtained on both tests in any of the parameters, except for maximum lactate concentration. Therefore, the Santos test can be considered a valid tool specific for judo training. PMID:23486994

  18. The influence of incubation time, sample preparation and exposure to oxygen on the quality of the MALDI-TOF MS spectrum of anaerobic bacteria.

    PubMed

    Veloo, A C M; Elgersma, P E; Friedrich, A W; Nagy, E; van Winkelhoff, A J

    2014-12-01

    With matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), bacteria can be identified quickly and reliably. This accounts especially for anaerobic bacteria. Because growth rate and oxygen sensitivity differ among anaerobic bacteria, we aimed to study the influence of incubation time, exposure to oxygen and sample preparation on the quality of the spectrum using the Bruker system. Also, reproducibility and inter-examiner variability were determined. Twenty-six anaerobic species, representing 17 genera, were selected based on gram-stain characteristics, growth rate and colony morphology. Inter-examiner variation showed that experience in the preparation of the targets can be a significant variable. The influence of incubation time was determined between 24 and 96 h of incubation. Reliable species identification was obtained after 48 h of incubation for gram-negative anaerobes and after 72 h for gram-positive anaerobes. Exposure of the cultures to oxygen did not influence the results of the MALDI-TOF MS identifications of all tested gram-positive species. Fusobacterium necrophorum and Prevotella intermedia could not be identified after >24 h and 48 h of exposure to oxygen, respectively. Other tested gram-negative bacteria could be identified after 48 h of exposure to oxygen. Most of the tested species could be identified using the direct spotting method. Bifidobacterium longum and Finegoldia magna needed on-target extraction with 70% formic acid in order to obtain reliable species identification and Peptoniphilus ivorii a full extraction. Spectrum quality was influenced by the amount of bacteria spotted on the target, the homogeneity of the smear and the experience of the examiner. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  19. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    PubMed

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P < .01) pCO2 (40.5 ± 2.8 vs 22.5 ± 1.6 mm Hg) and HCO3 - (25.5 ± 1.7 vs 22.7 ± 1.6 mmol/L) and increased (all P < .01) pH (7.41 ± 0.01 vs 7.61 ± 0.03) and actual base excess (1.4 ± 1.4 vs 3.2 ± 1.6 mmol/L) pre-WAnT with an ergogenic effect on WAnT average power (681 ± 41 vs 714 ± 44 W) and total metabolic energy (138 ± 12 vs. 144 ± 13 kJ) based on an increase in glycolytic energy (81 ± 13 vs 88 ± 13 kJ). Hyperventilation-induced respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  20. High-Intensity Interval Training with Vibration as Rest Intervals Attenuates Fiber Atrophy and Prevents Decreases in Anaerobic Performance

    PubMed Central

    Mueller, Sandro Manuel; Aguayo, David; Zuercher, Matthias; Fleischmann, Oliver; Boutellier, Urs; Auer, Maria; Jung, Hans H.; Toigo, Marco

    2015-01-01

    Aerobic high-intensity interval training (HIT) improves cardiovascular capacity but may reduce the finite work capacity above critical power (W′) and lead to atrophy of myosin heavy chain (MyHC)-2 fibers. Since whole-body vibration may enhance indices of anaerobic performance, we examined whether side-alternating whole-body vibration as a replacement for the active rest intervals during a 4x4 min HIT prevents decreases in anaerobic performance and capacity without compromising gains in aerobic function. Thirty-three young recreationally active men were randomly assigned to conduct either conventional 4x4 min HIT, HIT with 3 min of WBV at 18 Hz (HIT+VIB18) or 30 Hz (HIT+VIB30) in lieu of conventional rest intervals, or WBV at 30 Hz (VIB30). Pre and post training, critical power (CP), W′, cellular muscle characteristics, as well as cardiovascular and neuromuscular variables were determined. W′ (−14.3%, P = 0.013), maximal voluntary torque (−8.6%, P = 0.001), rate of force development (−10.5%, P = 0.018), maximal jumping power (−6.3%, P = 0.007) and cross-sectional areas of MyHC-2A fibers (−6.4%, P = 0.044) were reduced only after conventional HIT. CP, V̇O2peak, peak cardiac output, and overall capillary-to-fiber ratio were increased after HIT, HIT+VIB18, and HIT+VIB30 without differences between groups. HIT-specific reductions in anaerobic performance and capacity were prevented by replacing active rest intervals with side-alternating whole-body vibration, notably without compromising aerobic adaptations. Therefore, competitive cyclists (and potentially other endurance-oriented athletes) may benefit from replacing the active rest intervals during aerobic HIT with side-alternating whole-body vibration. Trial Registration ClinicalTrials.gov Identifier: NCT01875146 PMID:25679998

  1. Physiological and nutritional profile of elite female beach handball players from Brazil.

    PubMed

    Silva, Alexandre S; Coeli Seabra Marques, Rossana; DE Azevedo Lago, Silvio; Guedes Santos, Débora A; Lacerda, Lavoisiana M; Silva, Douglas C; Soares, Ytalo M

    2016-05-01

    This study evaluated the anthropometric, physiological and nutritional profiles of elite beach handball athletes. Additionally, the cardiometabolic demands of matches were characterized. Six players (24.7±2 years old, 168±0.08 cm, 63.8±7.1 kg) from Brazilian selection, which ranks first in the world, were characterized in terms of aerobic capacities, speeds, anaerobic capacities, muscle power and dietetic profiles. In an official match, heart rate and lactate production were measured. The athletes exhibited a VO2 max of 44.5±4.7 mL/kg/min, a 20-m speed of 3.214±0.43 seconds, a maximal anaerobic power of 337.3±126.3 watts and a long jump muscle power of 210.1±16.6 cm). The athletes had a mean body fat percentage of 24.9±3.0% and balanced macronutrient intakes. During the match, the lactate concentrations were 13.8 mM and 14.1 mM in the middle and at the end of the first set, respectively, and 11.7 mM and 12.0 mM in the middle and end of the second set, respectively. All players, with the exception of the goalkeeper, maintained a median heart rate of at least 123 bpm and no more than 196 bpm. The athletes exhibited only moderate aerobic capacities and better anaerobic and force capacities and high lactate production during the match.

  2. Antianaerobic Antimicrobials: Spectrum and Susceptibility Testing

    PubMed Central

    Wexler, Hannah M.; Goldstein, Ellie J. C.

    2013-01-01

    SUMMARY Susceptibility testing of anaerobic bacteria recovered from selected cases can influence the choice of antimicrobial therapy. The Clinical and Laboratory Standards Institute (CLSI) has standardized many laboratory procedures, including anaerobic susceptibility testing (AST), and has published documents for AST. The standardization of testing methods by the CLSI allows comparisons of resistance trends among various laboratories. Susceptibility testing should be performed on organisms recovered from sterile body sites, those that are isolated in pure culture, or those that are clinically important and have variable or unique susceptibility patterns. Organisms that should be considered for individual isolate testing include highly virulent pathogens for which susceptibility cannot be predicted, such as Bacteroides, Prevotella, Fusobacterium, and Clostridium spp.; Bilophila wadsworthia; and Sutterella wadsworthensis. This review describes the current methods for AST in research and reference laboratories. These methods include the use of agar dilution, broth microdilution, Etest, and the spiral gradient endpoint system. The antimicrobials potentially effective against anaerobic bacteria include beta-lactams, combinations of beta-lactams and beta-lactamase inhibitors, metronidazole, chloramphenicol, clindamycin, macrolides, tetracyclines, and fluoroquinolones. The spectrum of efficacy, antimicrobial resistance mechanisms, and resistance patterns against these agents are described. PMID:23824372

  3. Mathematical analysis of running performance and world running records.

    PubMed

    Péronnet, F; Thibault, G

    1989-07-01

    The objective of this study was to develop an empirical model relating human running performance to some characteristics of metabolic energy-yielding processes using A, the capacity of anaerobic metabolism (J/kg); MAP, the maximal aerobic power (W/kg); and E, the reduction in peak aerobic power with the natural logarithm of race duration T, when T greater than TMAP = 420 s. Accordingly, the model developed describes the average power output PT (W/kg) sustained over any T as PT = [S/T(1 - e-T/k2)] + 1/T integral of T O [BMR + B(1 - e-t/k1)]dt where S = A and B = MAP - BMR (basal metabolic rate) when T less than TMAP; and S = A + [Af ln(T/TMAP)] and B = (MAP - BMR) + [E ln(T/TMAP)] when T greater than TMAP; k1 = 30 s and k2 = 20 s are time constants describing the kinetics of aerobic and anaerobic metabolism, respectively, at the beginning of exercise; f is a constant describing the reduction in the amount of energy provided from anaerobic metabolism with increasing T; and t is the time from the onset of the race. This model accurately estimates actual power outputs sustained over a wide range of events, e.g., average absolute error between actual and estimated T for men's 1987 world records from 60 m to the marathon = 0.73%. In addition, satisfactory estimations of the metabolic characteristics of world-class male runners were made as follows: A = 1,658 J/kg; MAP = 83.5 ml O2.kg-1.min-1; 83.5% MAP sustained over the marathon distance. Application of the model to analysis of the evolution of A, MAP, and E, and of the progression of men's and women's world records over the years, is presented.

  4. Experimental continuous sludge microwave system to enhance dehydration ability and hydrogen production from anaerobic digestion of sludge.

    PubMed

    Zhou, Cuihong; Huang, Xintong; Zeng, Meng

    2018-05-01

    Dehydrating large amounts of sludge produced by sewage treatment plants is difficult. Microwave pretreatment can effectively and significantly improve the dewaterability and hydrogen production of sludge subjected to anaerobic digestion. The aim of this study was to investigate the effects of different microwave conditions on hydrogen production from anaerobic digestion and dewaterability of sludge. Based on an analysis of the electric field distribution, a spiral reactor was designed and a continuous microwave system was built to conduct intermittent and continuous experiments under different conditions. Settling Volume, Capillary Suction Time, particle size, and moisture content of the sludge were measured. The results show that sludge pretreatment in continuous experiments has equally remarkable dehydration performance as in intermittent experiments; the minimum moisture content was 77.29% in the intermittent experiment under a microwave power of 300W and an exposure time of 60sec, and that in the continuous experiment was 77.56% under a microwave power of 400W and an exposure time of 60sec. The peak measured by Differential Scanning Calorimeter appeared earliest under a microwave power of 600W and an exposure time of 180sec. The heat flux at the peak was 4.343W/g, which is relatively small. This indicates that microwave pretreatment induced desirable effects. The maximum yield of hydrogen production was 7.967% under the conditions of microwave power of 500W, exposure time of 120sec, and water bath at 55°C. This research provides a theoretical and experimental basis for the development of a continuous microwave sludge-conditioning system. Copyright © 2017. Published by Elsevier B.V.

  5. A comparison of methods to estimate anaerobic capacity: Accumulated oxygen deficit and W' during constant and all-out work-rate profiles.

    PubMed

    Muniz-Pumares, Daniel; Pedlar, Charles; Godfrey, Richard; Glaister, Mark

    2017-12-01

    This study investigated (i) whether the accumulated oxygen deficit (AOD) and curvature constant of the power-duration relationship (W') are different during constant work-rate to exhaustion (CWR) and 3-min all-out (3MT) tests and (ii) the relationship between AOD and W' during CWR and 3MT. Twenty-one male cyclists (age: 40 ± 6 years; maximal oxygen uptake [V̇O 2max ]: 58 ± 7 ml · kg -1 · min -1 ) completed preliminary tests to determine the V̇O 2 -power output relationship and V̇O 2max . Subsequently, AOD and W' were determined as the difference between oxygen demand and oxygen uptake and work completed above critical power, respectively, in CWR and 3MT. There were no differences between tests for duration, work, or average power output (P ≥ 0.05). AOD was greater in the CWR test (4.18 ± 0.95 vs. 3.68 ± 0.98 L; P = 0.004), whereas W' was greater in 3MT (9.55 ± 4.00 vs. 11.37 ± 3.84 kJ; P = 0.010). AOD and W' were significantly correlated in both CWR (P < 0.001, r = 0.654) and 3MT (P < 0.001, r = 0.654). In conclusion, despite positive correlations between AOD and W' in CWR and 3MT, between-test differences in the magnitude of AOD and W', suggest that both measures have different underpinning mechanisms.

  6. Assessment of the anaerobic degradation of six active pharmaceutical ingredients.

    PubMed

    Musson, Stephen E; Campo, Pablo; Tolaymat, Thabet; Suidan, Makram; Townsend, Timothy G

    2010-04-01

    Research examined the anaerobic degradation of 17 alpha-ethynylestradiol, acetaminophen, acetylsalicylic acid, ibuprofen, metoprolol tartrate, and progesterone by methanogenic bacteria. Using direct sample analysis and respirometric testing, anaerobic degradation was examined with (a) each compound as the sole organic carbon source and (b) each compound at a lower concentration (250 microg/L) and cellulose serving as the primary organic carbon source. The change in pharmaceutical concentration was determined following 7, 28, 56, and 112 days of anaerobic incubation at 37 degrees C. Only acetylsalicylic acid demonstrated significant degradation; the remaining compounds showed a mixture of degradation and abiotic removal mechanisms. Experimental results were compared with BIOWIN, an anaerobic degradation prediction model of the US Environmental Protection Agency. The BIOWIN model predicted anaerobic biodegradability of the compounds in the order: acetylsalicylic acid > metoprolol tartrate > ibuprofen > acetaminophen > 17 alpha-ethinylestradiol >progesterone. This corresponded well with the experimental findings which found degradability in the order: acetylsalicylic acid > metoprolol tartrate > acetaminophen > ibuprofen. (c) 2010 Elsevier B.V. All rights reserved.

  7. The inhibitory effects of free ammonia on ammonia oxidizing bacteria and nitrite oxidizing bacteria under anaerobic condition.

    PubMed

    Qian, Wenting; Peng, Yongzhen; Li, Xiyao; Zhang, Qiong; Ma, Bin

    2017-11-01

    The free ammonia (FA) inhibition on ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) under anaerobic condition was investigated in this study. The results indicated that NOB was more sensitive to the FA anaerobic treatment than AOB. The FA anaerobic inhibition on nitrifier gradually heightened with the increase of FA concentration. Accompanied with FA concentration increase from 0 to 16.82mgNH 3 -N·L -1 (the highest concentration adopted in this study), the activity of AOB reduced by 15.9%, while NOB decreased by 29.2%. After FA anaerobic treatment, nitrite was accumulated during nitrification. However, the nitrite accumulation disappeared on the sixth cycle of activity recovery tests with excessive aeration. Based on this result, a novel strategy for achieving nitritation is proposed, which involves recirculating a portion of the activated sludge through a side-line sludge treatment unit, where the sludge is subjected to treatment with FA under anaerobic condition. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Anaerobic biodegradability of Category 2 animal by-products: methane potential and inoculum source.

    PubMed

    Pozdniakova, Tatiana A; Costa, José C; Santos, Ricardo J; Alves, M M; Boaventura, Rui A R

    2012-11-01

    Category 2 animal by-products that need to be sterilized with steam pressure according Regulation (EC) 1774/2002 are studied. In this work, 2 sets of experiments were performed in mesophilic conditions: (i) biomethane potential determination testing 0.5%, 2.0% and 5.0% total solids (TS), using sludge from the anaerobic digester of a wastewater treatment plant as inoculum; (ii) biodegradability tests at a constant TS concentration of 2.0% and different inoculum sources (digested sludge from a wastewater treatment plant; granular sludge from an upflow anaerobic sludge blanket reactor; leachate from a municipal solid waste landfill; and sludge from the slaughterhouse wastewater treatment anaerobic lagoon) to select the more adapted inoculum to the substrate in study. The higher specific methane production was of 317 mL CH(4)g(-1) VS(substrate) for 2.0% TS. The digested sludge from the wastewater treatment plant led to the lowest lag-phase period and higher methane potential rate. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Laboratory-scale anaerobic sequencing batch reactor for treatment of stillage from fruit distillation.

    PubMed

    Rada, Elena Cristina; Ragazzi, Marco; Torretta, Vincenzo

    2013-01-01

    This work describes batch anaerobic digestion tests carried out on stillages, the residue of the distillation process on fruit, in order to contribute to the setting of design parameters for a planned plant. The experimental apparatus was characterized by three reactors, each with a useful volume of 5 L. The different phases of the work carried out were: determining the basic components of the chemical oxygen demand (COD) of the stillages; determining the specific production of biogas; and estimating the rapidly biodegradable COD contained in the stillages. In particular, the main goal of the anaerobic digestion tests on stillages was to measure the parameters of specific gas production (SGP) and gas production rate (GPR) in reactors in which stillages were being digested using ASBR (anaerobic sequencing batch reactor) technology. Runs were developed with increasing concentrations of the feed. The optimal loads for obtaining the maximum SGP and GPR values were 8-9 gCOD L(-1) and 0.9 gCOD g(-1) volatile solids.

  10. Toluene inhibition on an anaerobic reactor sludge in terms of potential activity and composition of acetoclastic methanogens.

    PubMed

    Ince, Orhan; Kolukirik, Mustafa; Cetecioglu, Zeynep; Eyice, Ozge; Inceoglu, Ozgul; Ince, Bahar

    2009-12-01

    The aim of this study was to determine the effect of toluene on an anaerobic sludge taken from a full-scale upflow anaerobic sludge blanket (UASB) reactor in terms of potential activity and composition of acetoclastic methanogens. Specific methanogenic activity (SMA) test results showed that 5%, 9.5%, 14%, 24%, 29%, 38% and 62% inhibition occurred in the potential methane production (PMP) rate of the sludge at toluene concentrations of 0.1 mM, 0.2 mM, 0.3 mM, 0.4 mM, 0.5 mM, 0.6 mM and 1 mM, respectively. Fluorescence in situ hybridization (FISH) results showed that relative abundance of archaeal cells was approx. 19% throughout the SMA tests. The anaerobic sludge was dominated by acetoclastic genus Methanosaeta which were slightly affected by increasing toluene concentrations do not have any effect on relative abundance of Methanosaeta spp., which was between 73% +/- 1.6 and 68% +/- 2.1 of the archaeal population.

  11. Oxygen requirements of yeasts. [Saccharomyces cerevisiae; Candida tropicalis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Visser, W.; Scheffers, W.A.; Batenburg-Van Der Vegte, W.H.

    1990-12-01

    Type species of 75 yeast genera were examined for their ability to grow anaerobically in complex and mineral media. To define anaerobic conditions, we added a redox indicator, resazurin, to the media to determine low redox potentials. All strains tested were capable of fermenting glucose to ethanol in oxygen-limited shake-flask cultures, even those of species generally regarded as nonfermentative. However, only 23% of the yeast species tested grew under anaerobic conditions. A comparative study with a number of selected strains revealed that Saccharomyces cerevisiae stands out as a yeast capable of rapid growth at low redox potentials. Other yeasts, suchmore » as Torulaspora delbrueckii and Candida tropicalis, grew poorly ({mu}{sub max}, 0.03 and 0.05 h{sup {minus}1}, respectively) under anaerobic conditions in mineral medium supplemented with Tween 80 and ergosterol. The latter organisms grew rapidly under oxygen limitation and then displayed a high rate of alcoholic fermentation. It can be concluded that these yeasts have hitherto-unidentified oxygen requirements for growth.« less

  12. Reduced Bacterial Colony Count of Anaerobic Bacteria Is Associated with a Worsening in Lung Clearance Index and Inflammation in Cystic Fibrosis

    PubMed Central

    Bradley, Judy M.; Johnston, Elinor; McGrath, Stephanie; McIlreavey, Leanne; Rowan, Stephen; Reid, Alastair; Bradbury, Ian; Einarsson, Gisli

    2015-01-01

    Anaerobic bacteria have been identified in abundance in the airways of cystic fibrosis (CF) subjects. The impact their presence and abundance has on lung function and inflammation is unclear. The aim of this study was to investigate the relationship between the colony count of aerobic and anaerobic bacteria, lung clearance index (LCI), spirometry and C-Reactive Protein (CRP) in patients with CF. Sputum and blood were collected from CF patients at a single cross-sectional visit when clinically stable. Community composition and bacterial colony counts were analysed using extended aerobic and anaerobic culture. Patients completed spirometry and a multiple breath washout (MBW) test to obtain LCI. An inverse correlation between colony count of aerobic bacteria (n = 41, r = -0.35; p = 0.02), anaerobic bacteria (n = 41, r = -0.44, p = 0.004) and LCI was observed. There was an inverse correlation between colony count of anaerobic bacteria and CRP (n = 25, r = -0.44, p = 0.03) only. The results of this study demonstrate that a lower colony count of aerobic and anaerobic bacteria correlated with a worse LCI. A lower colony count of anaerobic bacteria also correlated with higher CRP levels. These results indicate that lower abundance of aerobic and anaerobic bacteria may reflect microbiota disruption and disease progression in the CF lung. PMID:25992575

  13. Reduced bacterial colony count of anaerobic bacteria is associated with a worsening in lung clearance index and inflammation in cystic fibrosis.

    PubMed

    O'Neill, Katherine; Bradley, Judy M; Johnston, Elinor; McGrath, Stephanie; McIlreavey, Leanne; Rowan, Stephen; Reid, Alastair; Bradbury, Ian; Einarsson, Gisli; Elborn, J Stuart; Tunney, Michael M

    2015-01-01

    Anaerobic bacteria have been identified in abundance in the airways of cystic fibrosis (CF) subjects. The impact their presence and abundance has on lung function and inflammation is unclear. The aim of this study was to investigate the relationship between the colony count of aerobic and anaerobic bacteria, lung clearance index (LCI), spirometry and C-Reactive Protein (CRP) in patients with CF. Sputum and blood were collected from CF patients at a single cross-sectional visit when clinically stable. Community composition and bacterial colony counts were analysed using extended aerobic and anaerobic culture. Patients completed spirometry and a multiple breath washout (MBW) test to obtain LCI. An inverse correlation between colony count of aerobic bacteria (n = 41, r = -0.35; p = 0.02), anaerobic bacteria (n = 41, r = -0.44, p = 0.004) and LCI was observed. There was an inverse correlation between colony count of anaerobic bacteria and CRP (n = 25, r = -0.44, p = 0.03) only. The results of this study demonstrate that a lower colony count of aerobic and anaerobic bacteria correlated with a worse LCI. A lower colony count of anaerobic bacteria also correlated with higher CRP levels. These results indicate that lower abundance of aerobic and anaerobic bacteria may reflect microbiota disruption and disease progression in the CF lung.

  14. Anaerobic Work Capacity derived from isokinetic and isoinertial cycling.

    PubMed

    Wiedemann, M S F; Bosquet, L

    2010-02-01

    The purpose of this study was to compare Anaerobic Work Capacity (AWC) measured on an isoinertial or an isokinetic bicycle ergometer. Twelve male participants completed two randomly ordered exercise testing sessions including a torque-velocity test followed by a 30-s all-out test on an isokinetic ergometer, or a force-velocity test followed by a Wingate Anaerobic Test on an isoinertial ergometer. Optimal load measured during the force-velocity test on the isoinertial ergometer was 1.13+/-0.11 N.kg(-1). Optimal cadence measured during the torque-velocity test on the isokinetic ergometer was 107+/-13 rpm. Although P(peak) measures were significantly correlated (r=0.77), we found a large difference between them (effect size=2.85) together with wide limits of agreement (bias+/-95%LOA=24+/-12%). The same observation was made with P(mean), but with a smaller magnitude of difference (bias+/-95%LOA=4.2+/-12%; effect size=0.51; r=0.73). This lack of agreement led us to the conclusion that AWC measures obtained during 30-s all-out tests performed on an isoinertial or an isokinetic bicycle ergometer are not necessarily similar and cannot be used interchangeably.

  15. Effect of ultrasonication on anaerobic degradability of solid waste digestate.

    PubMed

    Boni, M R; D'Amato, E; Polettini, A; Pomi, R; Rossi, A

    2016-02-01

    This paper evaluates the effect of ultrasonication on anaerobic biodegradability of lignocellulosic residues. While ultrasonication has been commonly applied as a pre-treatment of the feed substrate, in the present study a non-conventional process configuration based on recirculation of sonicated digestate to the biological reactor was evaluated at the lab-scale. Sonication tests were carried out at different applied energies ranging between 500 and 50,000kJ/kg TS. Batch anaerobic digestion tests were performed on samples prepared by mixing sonicated and untreated substrate at two different ratios (25:75 and 75:25 w/w). The results showed that when applied as a post-treatment of digestate, ultrasonication can positively affect the yield of anaerobic digestion, mainly due to the dissolution effect of complex organic molecules that have not been hydrolyzed by biological degradation. A good correlation was found between the CH4 production yield and the amount of soluble organic matter at the start of digestion tests. The maximum gain in biogas production was 30% compared to that attained with the unsonicated substrate, which was tentatively related to the type and concentration of the metabolic products. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Combined bioaugmentation with anaerobic ruminal fungi and fermentative bacteria to enhance biogas production from wheat straw and mushroom spent straw.

    PubMed

    Ferraro, Alberto; Dottorini, Giulia; Massini, Giulia; Mazzurco Miritana, Valentina; Signorini, Antonella; Lembo, Giuseppe; Fabbricino, Massimiliano

    2018-07-01

    Bioaugmentation with anaerobic ruminal fungi and a pool of hydrogen-producing fermenting bacteria was tested on wheat straw (WS) and mushroom spent straw (MSS) with the aim of improving anaerobic digestion performance. Batch tests were set up to simulate a Bioaugmentation Anaerobic Digestion (BAD) treatment comparing single- (I-BAD) and two-stage (II-BAD) process configurations, at two reactor scales, 120 and 1200 ml (×10). In both cases, higher CH 4 cumulative production was obtained in the II-BAD configuration on WS (65.1 ± 8.9 Nml and 922 ± 73.8 Nml respectively). The II-BADx10 tests allowed increasing CH 4 production (≃290% and ≃330% on WS and MSS, respectively) when compared to the unaugmented condition. Final results highlighted the achievable advantages of the two stage configuration in terms of CH 4 production enhancement. Microbial community investigations confirmed the efficiency of the bioaugmentation treatment and revealed that such a result was mainly related to the Methanosarcinales increase, mostly composed by Methanosaeta. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. [A Polish multicenter survey of antimicrobial susceptibility and prevalence of beta-lactamase production among bacterial pathogens isolated from hospitalized and ambulatory patients].

    PubMed

    Zwolska, Z; Jezierska-Anczuków, A; Filczak, K; Basta, M; Dworzyński, A; Rogala-Zawada, D; Samet, A

    1998-05-01

    The aim of the study was to establish the frequency of occurrence of bacterial pathogens with beta-lactamase activity, and pattern of resistance among aerobic and anaerobic strains isolated from: respiratory tract, urinary tract, skin and soft tissues (hospitalized patients) and throat swabs (ambulatory patients). The study was conducted in 1994 year in 6 bacteriological laboratories in four Polish towns (Warszawa, Kraków, Katowice, Gdańsk) according to the protocol. Sensitivity of bacteria was tested by the disc method on the Müeller-Hinton agar or chocolate agar according to NCCLS, activity of beta-lactamase was tested with nitrocephin. A total 2038 clinical strains--1869 aerobic and 169 anaerobic was well-defined and tested for susceptibility to ten antibiotics--amoxicilin, augmentin, ofloxacin, gentamycin, cefradin, erythromycin, cefuroxim, kotrimoxazol, cefalexin and cefaclor. Among the isolated aerobes Staphylococcus aureus (25.1%), E. coli (23.2%) and Haemophilus influenzae (14.0%) were most frequent, and in the group of anaerobes the most frequent were Bacteroides spp (40.8%) We have found 45.8% of all tested aerobic strains with beta-lactamase production, the highest proportion in pathogens isolated from respiratory tract--51.4%, 46.6% from urinary tract, and 48.4% from skin and soft tissues. Among the isolated anaerobic--68.8% of Bacteroides and 28.6% others produced beta-lactamase. Forty percentage of all strains were sensitive to amoxicilin, 70-90% of aerobic bacteria were sensitive to augmentin. Augmentin had a high activity against anaerobic bacteria too. Only a small proportion of the tested aerobic bacteria (12.2%) were resistant to ofloxacin, gentamycin showed a sufficient activity against tested strains (24.4% were resistant). The most frequent pathogen--Staphylococcus aureus was resistant to amoxicilin in 83.1% hospitalized patients, and in 73.9% in ambulatory patients.

  18. Methanogenic activity tests by Infrared Tunable Diode Laser Absorption Spectroscopy.

    PubMed

    Martinez-Cruz, Karla; Sepulveda-Jauregui, Armando; Escobar-Orozco, Nayeli; Thalasso, Frederic

    2012-10-01

    Methanogenic activity (MA) tests are commonly carried out to estimate the capability of anaerobic biomass to treat effluents, to evaluate anaerobic activity in bioreactors or natural ecosystems, or to quantify inhibitory effects on methanogenic activity. These activity tests are usually based on the measurement of the volume of biogas produced by volumetric, pressure increase or gas chromatography (GC) methods. In this study, we present an alternative method for non-invasive measurement of methane produced during activity tests in closed vials, based on Infrared Tunable Diode Laser Absorption Spectroscopy (MA-TDLAS). This new method was tested during model acetoclastic and hydrogenotrophic methanogenic activity tests and was compared to a more traditional method based on gas chromatography. From the results obtained, the CH(4) detection limit of the method was estimated to 60 ppm and the minimum measurable methane production rate was estimated to 1.09(.)10(-3) mg l(-1) h(-1), which is below CH(4) production rate usually reported in both anaerobic reactors and natural ecosystems. Additionally to sensitivity, the method has several potential interests compared to more traditional methods among which short measurements time allowing the measurement of a large number of MA test vials, non-invasive measurements avoiding leakage or external interferences and similar cost to GC based methods. It is concluded that MA-TDLAS is a promising method that could be of interest not only in the field of anaerobic digestion but also, in the field of environmental ecology where CH(4) production rates are usually very low. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. The Effects of Low Dose Buccal Administered Caffeine on RPE and Pain during an Upper Body Muscle Endurance Test and Lower Body Anaerobic Test

    ERIC Educational Resources Information Center

    Bellar, David M.; Judge, Lawrence W.; Kamimori, Gary H.; Glickman, Ellen L.

    2012-01-01

    To date there have been a number of studies that have assessed the effects of caffeine on Rated Perceived Exertion (RPE) and Pain Scale scores during continuous exercise. Presently there is little information about the effects of caffeine on RPE and Pain Scale scores during short term, anaerobic and muscle endurance activity. The purpose of the…

  20. Renewable Biochemical Methane Potential through Anaerobic Co-digestion from Selective Feed Stocks

    NASA Astrophysics Data System (ADS)

    Thara, K.; Navis Karthika, Ignatius; Dheenadayalan, M. S., Dr

    2017-08-01

    Biochemical Methane Potential (BMP) analysis provides a measure of the anaerobic biodegradability of a given substrate. BMP test is also used to evaluate the potential biogas (methane) production between various Co-digestion substrates. This test is also used to determine the amount of organic carbon in a given material that can be an aerobically converted to methane-Biogas. Studies were carried out for the production of biogas from the leather solid waste. Co-digestion (simultaneous digestion of two or more substrates) studies were carried out in batch reactor using the fleshing (a solid waste generated during the processing of raw hides or skins into finished leather) along with the fruit and vegetable waste at mesophilic condition 35° C). The anaerobic methanogenic seed sludge prepared separately followed by standard BMP test, which was used as the seed inoculums. Recent research on this topic is reviewed in this current paper.

  1. Bioelectrochemically-assisted anaerobic composting process enhancing compost maturity of dewatered sludge with synchronous electricity generation.

    PubMed

    Yu, Hang; Jiang, Junqiu; Zhao, Qingliang; Wang, Kun; Zhang, Yunshu; Zheng, Zhen; Hao, Xiaodi

    2015-10-01

    Bioelectrochemically-assisted anaerobic composting process (AnCBE) with dewatered sludge as the anode fuel was constructed to accelerate composting of dewatered sludge, which could increase the quality of the compost and harvest electric energy in comparison with the traditional anaerobic composting (AnC). Results revealed that the AnCBE yielded a voltage of 0.60 ± 0.02 V, and total COD (TCOD) removal reached 19.8 ± 0.2% at the end of 35 d. The maximum power density was 5.6 W/m(3). At the end of composting, organic matter content (OM) reduction rate increased to 19.5 ± 0.2% in AnCBE and to 12.9 ± 0.1% in AnC. The fuzzy comprehensive assessment (FCA) result indicated that the membership degree of class I of AnCBE compost (0.64) was higher than that of AnC compost (0.44). It was demonstrated that electrogenesis in the AnCBE could improve the sludge stabilization degree, accelerate anaerobic composting process and enhance composting maturity with bioelectricity generation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Muscle contractile characteristics: relationship to high-intensity exercise.

    PubMed

    Morris, Martyn G; Dawes, Helen; Howells, Ken; Scott, Oona M; Cramp, Mary; Izadi, Hooshang

    2010-09-01

    We investigated the relationship between muscle contractile characteristics, collected using percutaneous electrical stimulation, and high-intensity exercise performance. Seventeen participants performed a muscle performance test for the calculation of rate of torque development (RTD), rate of relaxation (RR(1/2)), rate of fatigue and fatigue resistance. On a second visit the participants completed a Wingate cycle ergometer test with peak power, mean power, fatigue index and fatigue rate calculated. The muscle fatigue index related significantly to the WAnT fatigue index and fatigue rate (p < 0.01). The change in rate of torque development (%DeltaRTD) was also related significantly to the fatigue rate (W/s) during the WAnT. Subjects displaying the greatest reduction in RTD had the greatest fatigue rate during the WAnT and greater fatigue during the electrical stimulation protocol. There were no significant relationships between peak (r 0.36; p > 0.01) or mean power (r -0.11, p > 0.01) with any of the muscle performance measures. These findings demonstrate that muscle contractile characteristics, elicited during standardised in vivo electrical stimulation, relate to performance during a Wingate anaerobic test. They suggest that muscle contraction characteristics play an important role in high-intensity exercise performance and indicate that electrical stimulation protocols can be a useful additional tool to explore muscle contraction characteristics in relation to exercise performance and trainability.

  3. TREATMENT OF CERCLA (COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION, AND LIABILITY ACT) LEACHATES BY CARBON-ASSISTED ANAEROBIC FLUIDIZED BEDS (Journal)

    EPA Science Inventory

    Two anaerobic granular activated carbon (GAC) expanded-bed bioreactors were tested as pretreatment units for the decontamination of hazardous leachates containing volatile and semivolatile synthetic organic chemicals (SOCs). The different characteristics of the two leachate feed...

  4. Repeated sprint ability related to recovery time in young soccer players.

    PubMed

    Padulo, J; Tabben, M; Ardigò, L P; Ionel, M; Popa, C; Gevat, C; Zagatto, A M; Dello Iacono, A

    2015-01-01

    This study aimed to describe the influence of recovery duration during a repeated sprint ability (RSA) test (6 × 40 m) by investigating a number of variables, such as general performance, metabolic demand, and muscular stretch-shortening performance. Seventeen male soccer outfield players (16 ± 0 years, 66 ± 10 kg) performed three field shuttle-running tests with 15, 20, and 25-sec recoveries. In addition to specific shuttle test's variables, blood lactate concentration and vertical jump height were assessed. Resulting measures were highly reliable (intra-class correlation coefficient up to 0.86). 25-sec recovery improved test performance (-3% total time from 15-sec to 25-sec recovery), vertical jump height (+7% post-test height from 15-sec to 25-sec recovery), and decreased blood lactate accumulation (-33% post-test from 15-sec to 25-sec recovery). Study findings suggest that metabolic acidosis plays a role in worsening performance and fatigue development during the shuttle test. A 25-sec recovery duration maximized performance, containing metabolic-anaerobic power involvement and muscular stretch-shortening performance deterioration during a RSA test.

  5. Transposon Mutagenesis Identified Chromosomal and Plasmid Genes Essential for Adaptation of the Marine Bacterium Dinoroseobacter shibae to Anaerobic Conditions

    PubMed Central

    Ebert, Matthias; Laaß, Sebastian; Burghartz, Melanie; Petersen, Jörn; Koßmehl, Sebastian; Wöhlbrand, Lars; Rabus, Ralf; Wittmann, Christoph; Jahn, Dieter

    2013-01-01

    Anaerobic growth and survival are integral parts of the life cycle of many marine bacteria. To identify genes essential for the anoxic life of Dinoroseobacter shibae, a transposon library was screened for strains impaired in anaerobic denitrifying growth. Transposon insertions in 35 chromosomal and 18 plasmid genes were detected. The essential contribution of plasmid genes to anaerobic growth was confirmed with plasmid-cured D. shibae strains. A combined transcriptome and proteome approach identified oxygen tension-regulated genes. Transposon insertion sites of a total of 1,527 mutants without an anaerobic growth phenotype were determined to identify anaerobically induced but not essential genes. A surprisingly small overlap of only three genes (napA, phaA, and the Na+/Pi antiporter gene Dshi_0543) between anaerobically essential and induced genes was found. Interestingly, transposon mutations in genes involved in dissimilatory and assimilatory nitrate reduction (napA, nasA) and corresponding cofactor biosynthesis (genomic moaB, moeB, and dsbC and plasmid-carried dsbD and ccmH) were found to cause anaerobic growth defects. In contrast, mutation of anaerobically induced genes encoding proteins required for the later denitrification steps (nirS, nirJ, nosD), dimethyl sulfoxide reduction (dmsA1), and fermentation (pdhB1, arcA, aceE, pta, acs) did not result in decreased anaerobic growth under the conditions tested. Additional essential components (ferredoxin, cccA) of the anaerobic electron transfer chain and central metabolism (pdhB) were identified. Another surprise was the importance of sodium gradient-dependent membrane processes and genomic rearrangements via viruses, transposons, and insertion sequence elements for anaerobic growth. These processes and the observed contributions of cell envelope restructuring (lysM, mipA, fadK), C4-dicarboxylate transport (dctM1, dctM3), and protease functions to anaerobic growth require further investigation to unravel the novel underlying adaptation strategies. PMID:23974024

  6. Assessment of Maximum Aerobic Capacity and Anaerobic Threshold of Elite Ballet Dancers.

    PubMed

    Wyon, Matthew A; Allen, Nick; Cloak, Ross; Beck, Sarah; Davies, Paul; Clarke, Frances

    2016-09-01

    An athlete's cardiorespiratory profile, maximal aerobic capacity, and anaerobic threshold is affected by training regimen and competition demands. The present study aimed to ascertain whether there are company rank differences in maximal aerobic capacity and anaerobic threshold in elite classical ballet dancers. Seventy-four volunteers (M 34, F 40) were recruited from two full-time professional classical ballet companies. All participants completed a continuous incremental treadmill protocol with a 1-km/hr speed increase at the end of each 1-min stage until termination criteria had been achieved (e.g., voluntary cessation, respiratory exchange ratio <1.15, HR ±5 bpm of estimated HRmax). Peak VO2 (5-breathe smooth) was recorded and anaerobic threshold calculated using ventilatory curve and ventilatory equivalents methods. Statistical analysis reported between-subject effects for gender (F1,67=35.18, p<0.001) and rank (F1,67=8.67, p<0.001); post hoc tests reported soloists (39.5±5.15 mL/kg/min) as having significantly lower VO2 peak than artists (45.9±5.75 mL/kg/min, p<0.001) and principal dancers (48.07±3.24 mL/kg/min, p<0.001). Significant differences in anaerobic threshold were reported for age (F1,67=7.68, p=0.008) and rank (F1,67=3.56, p=0.034); post hoc tests reported artists (75.8±5.45%) having significantly lower anaerobic threshold than soloists (80.9±5.71, p<0.01) and principals (84.1±4.84%, p<0.001). The observed differences in VO2 peak and anaerobic threshold between the ranks in ballet companies are probably due to the different rehearsal and performance demands.

  7. Anaerobic Digestion Model No. 1 Simulation of High Solids Anaerobic Digestion with Feasibility Study for El Gabal El Asfar Water Resource Recovery Facility.

    PubMed

    Aboulfotoh, Ahmed M

    2018-03-01

      Performance of continuous mesophilic high solids anaerobic digestion (HSAD) was simulated using Anaerobic Digestion Model No. 1 (ADM1), under different conditions (solids concentrations, sludge retention time (SRT), organic loading rate (OLR), and type of sludge). Implementation of ADM1, using the proposed biochemical parameters, proved to be a useful tool for the prediction and control of HSAD as the model predicted the behavior of the tested sets of data with considerable accuracy, especially for SRT more than 13 days. The model was then used to investigate the possibility of changing the existing conventional anaerobic digestion (CAD) units in Gabal El Asfar water resource recovery facility into HSAD, instead of establishing new CAD units, and results show that the system will be feasible. HSAD will produce the same bioenergy combined with a decrease in capital, operational, and maintenance costs.

  8. Total Protein of Whole Saliva as a Biomarker of Anaerobic Threshold

    ERIC Educational Resources Information Center

    Bortolini, Miguel Junior Sordi; De Agostini, Guilherme Gularte; Reis, Ismair Teodoro; Lamounier, Romeu Paulo Martins Silva; Blumberg, Jeffrey B.; Espindola, Foued Salmen

    2009-01-01

    Saliva provides a convenient and noninvasive matrix for assessing specific physiological parameters, including some biomarkers of exercise. We investigated whether the total protein concentration of whole saliva (TPWS) would reflect the anaerobic threshold during an incremental exercise test. After a warm-up period, 13 nonsmoking men performed a…

  9. In Vitro Activity of Penicillins Against Anaerobes

    PubMed Central

    Tally, Francis P.; Jacobus, Nilda V.; Bartlett, John G.; Gorbach, Sherwood L.

    1975-01-01

    The in vitro susceptibility of 162 anaerobic isolates from clinical material were tested to pencillin G, BL-P1654, and carbenicillin. Penicillin G and BL-P1654 showed good activity against Bacteroides fragilis, but only 60% of strains were susceptible to carbenicillin at achievable blood levels (128 μg/ml). PMID:1041215

  10. Continuous treatment of N-Methyl-p-nitro aniline (MNA) in an Upflow Anaerobic Sludge Blanket (UASB) bioreactor

    PubMed Central

    Olivares, Christopher I.; Wang, Junqin; Silva Luna, Carlos D.; Field, Jim A.; Abrell, Leif; Sierra-Alvarez, Reyes

    2017-01-01

    N-methyl-p-nitroaniline (MNA) is an ingredient of insensitive munitions (IM) compounds that serves as a plasticizer and helps reduce unwanted detonations. As its use becomes widespread, MNA waste streams will be generated, necessitating viable treatment options. We studied MNA biodegradation and its inhibition potential to, a representative anaerobic microbial population in wastewater treatment, methanogens. Anaerobic biodegradation and toxicity assays were performed and an up-flow anaerobic sludge blanket reactor (UASB) was operated to test continuous degradation of MNA. MNA was transformed almost stoichiometrically to N-methyl-p-phenylenediamine (MPD). MPD was not mineralized, however, it was readily autoxidized and polymerized extensively upon aeration at pH = 9. In the UASB reactor, MNA was fully degraded up to a loading rate of 297.5 μM MNA d-1). Regarding toxicity, MNA was very inhibitory to acetoclastic methanogens (IC50 = 103 μM) whereas MPD was much less toxic, causing only 13.9% inhibition at the highest concentration tested (1025 μM). The results taken as a whole indicate that anaerobic sludge can transform MNA to MPD continuously, and that the transformation decreases the cytotoxicity of the parent pollutant. MPD can be removed through extensive polymerization. These insights could help define efficient treatment options for waste streams polluted with MNA. PMID:26454121

  11. An in vitro time-kill assessment of linezolid and anaerobic bacteria.

    PubMed

    Yagi, Betty H; Zurenko, Gary E

    2003-02-01

    Linezolid is a novel oxazolidinone antibacterial agent active against staphylococci (including methicillin-resistant strains), enterococci (including vancomycin-resistant strains), streptococci (including penicillin-intermediate and -resistant Streptococcus pneumoniae), and other aerobic and facultative bacteria. The agent has also demonstrated activity against a broad spectrum of Gram-positive and Gram-negative anaerobic bacteria. Previous time-kill assessments have shown linezolid to be generally bacteriostatic against staphylococci and enterococci, and bactericidal against streptococci. In this study, an anaerobic glovebox technique was employed to conduct time-kill assessments for four strains of anaerobic Gram-positive, and seven strains of anaerobic Gram-negative bacteria. The time-kill experiment was performed using Anaerobe Broth medium. The drugs were tested at four-fold the minimum inhibitory concentration (MIC), or at the higher concentration of 8mg/L for linezolid, 2mg/L for clindamycin, and 8mg/L for metronidazole. Samples for viable count were taken at 0, 6, and 24h, and plated using the Bioscience International Autospiral DW. Exposure of samples to the aerobic environment during plating was held to less than 30min. Plates were counted after a 48h anaerobic incubation (37 degrees C). The species tested included Bacteroides fragilis (2), B. distasonis, B. thetaiotaomicron, Fusobacterium nucleatum, F. varium, Prevotella melaninogenica, Clostridium perfringens, Eubacterium lentum and Peptostreptococcus anaerobius (2). The activity of linezolid was compared to that of metronidazole and clindamycin, two standard anti-anaerobe agents. As expected, the control agents were very active in these assays. Metronidazole yielded log(10)CFU/mL reductions of 3.0 or greater for nine of ten strains; clindamycin yielded log(10)CFU/mL reductions of 2.0 or greater for six of 11 strains, and 3.0 or greater for three strains. Linezolid also produced significant in vitro killing in this model achieving log(10)CFU/mL reductions of 2.0 or greater for six of 11 strains, and 3.0 or greater for four strains. The profile of activity was similar to that of clindamycin indicating that additional developmental studies of linezolid with anaerobic bacteria are warranted.

  12. Anaerobic digestion of Chinese cabbage waste silage with swine manure for biogas production: batch and continuous study.

    PubMed

    Kafle, Gopi Krishna; Bhattarai, Sujala; Kim, Sang Hun; Chen, Lide

    2014-01-01

    The aim of this study was to investigate the potential for anaerobic co-digestion of Chinese cabbage waste silage (CCWS) with swine manure (SM). Batch and continuous experiments were carried out under mesophilic anaerobic conditions (36-38°C). The batch test evaluated the effect of CCWS co-digestion with SM (SM: CCWS=100:0; 25:75; 33:67; 0:100, % volatile solids (VS) basis). The continuous test evaluated the performance of a single stage completely stirred tank reactor with SM alone and with a mixture of SM and CCWS. Batch test results showed no significant difference in biogas yield up to 25-33% of CCWS; however, biogas yield was significantly decreased when CCWS contents in feed increased to 67% and 100%. When testing continuous digestion, the biogas yield at organic loading rate (OLR) of 2.0 g VSL⁻¹ d⁻¹ increased by 17% with a mixture of SM and CCWS (SM:CCWS=75:25) (423 mL g⁻¹ VS) than with SM alone (361 mL g⁻¹ VS). The continuous anaerobic digestion process (biogas production, pH, total volatile fatty acids (TVFA) and TVFA/total alkalinity ratios) was stable when co-digesting SM and CCWS (75:25) at OLR of 2.0 g VSL⁻¹ d⁻¹ and hydraulic retention time of 20 days under mesophilic conditions.

  13. O2-Dependent Efficacy of Novel Piperidine- and Piperazine-Based Chalcones against the Human Parasite Giardia intestinalis

    PubMed Central

    Bahadur, Vijay; Mastronicola, Daniela; Tiwari, Hemandra Kumar; Kumar, Yogesh; Falabella, Micol; Pucillo, Leopoldo Paolo; Sarti, Paolo

    2014-01-01

    Giardia intestinalis is the most frequent protozoan agent of intestinal diseases worldwide. Though commonly regarded as an anaerobic pathogen, it preferentially colonizes the fairly oxygen-rich mucosa of the proximal small intestine. Therefore, when testing new potential antigiardial drugs, O2 should be taken into account, since it also reduces the efficacy of metronidazole, the gold standard drug against giardiasis. In this study, 46 novel chalcones were synthesized by microwave-assisted Claisen-Schmidt condensation, purified, characterized by high-resolution mass spectrometry, 1H and 13C nuclear magnetic resonance, and infrared spectroscopy, and tested for their toxicity against G. intestinalis under standard anaerobic conditions. As a novel approach, compounds showing antigiardial activity under anaerobiosis were also assayed under microaerobic conditions, and their selectivity against parasitic cells was assessed in a counterscreen on human epithelial colorectal adenocarcinoma cells. Among the tested compounds, three [30(a), 31(e), and 33] were more effective in the presence of O2 than under anaerobic conditions and killed the parasite 2 to 4 times more efficiently than metronidazole under anaerobiosis. Two of them [30(a) and 31(e)] proved to be selective against parasitic cells, thus representing potential candidates for the design of novel antigiardial drugs. This study highlights the importance of testing new potential antigiardial agents not only under anaerobic conditions but also at low, more physiological O2 concentrations. PMID:24217695

  14. The relationship of maximal alactacid anaerobic power to somatotype in trained subjects.

    PubMed Central

    Ergen, E; Sardella, F; Dal Monte, A

    1985-01-01

    The purpose of the present study was to investigate the relationship between somatotype components and maximal alactacid anaerobic power (MAAP) in trained subjects. The somatotype components (endomorphy: means = 2.66, S.D. = +/- 0.78; mesomorphy: means = 5.45, S.D. = +/- 1.12; ectomorphy: means = 2.46, S.D. = +/- 0.88) and total MAAP were measured in 40 male fencers (aged, means 21.79, S.D. = +/- 3.97) in order to determine the correlations. The results did not show any correlations between the parameters. It can be concluded that the MAAP of an individual does not depend on the somatotype; but it may also be assumed that MAAP show changes with the percentage of fibre type, enzymatic activity in these fibres involved by large muscle groups which are relatively related to musculo-skeletal development (second component of somatotype) and neuro-muscular properties of the subjects, all having a genetic basis. PMID:4092145

  15. Analysis of problems with dry fermentation process for biogas production

    NASA Astrophysics Data System (ADS)

    Pilát, Peter; Patsch, Marek; Jandačka, Jozef

    2012-04-01

    The technology of dry anaerobic fermentation is still meeting with some scepticism, and therefore in most biogas plants are used wet fermentation technology. Fermentation process would be not complete without an optimal controlled condition: dry matter content, density, pH, and in particular the reaction temperature. If is distrust of dry fermentation eligible it was on the workplace of the Department of Power Engineering at University of Zilina built an experimental small-scale biogas station that allows analysis of optimal parameters of the dry anaerobic fermentation, in particular, however, affect the reaction temperature on yield and quality of biogas.

  16. Visual Impairment does not Limit Training Effects in Development of Aerobic and Anaerobic Capacity in Tandem Cyclists

    PubMed Central

    Malwina, Kamelska Anna; Krzysztof, Mazurek; Piotr, Zmijewski

    2015-01-01

    The study aimed to investigate the differences in the effects of 7-month training on aerobic and anaerobic capacity in tandem cycling athletes with and without visual impairment. In this study, Polish elite (n=13) and sub-elite (n=13) visually impaired (VI) (n=13; 40.8 ±12.8 years) and properly sighted (PS) (n=13; 36.7 ±12.2 years) tandem-cycling athletes participated voluntarily in 7-month routine training. The following pre-/post-training measurements were conducted on separate days: maximal oxygen uptake (VO2max) was estimated with age correction using the Physical Working Capacity test on a bicycle ergometer according to the Astrand-Ryhming method. Maximal power output (Pmax) was evaluated using the Quebec test on a bicycle ergometer. At baseline, VO2max (47.8 ±14.1 vs 42.0 ±8.3 ml/kg/min, respectively) and Pmax (11.5 ±1.5 vs 11.5 ±1.0 W/kg) did not differ significantly between PS and VI cyclists. However, differences in aerobic capacity were considered as clinically significant. Two-way ANOVA revealed that after 7 month training, there were statistically significant increases in VO2max (p=0.003) and Pmax (p=0.009) among VI (VO2max, +9.1%; Pmax, +6.3%) and PS (VO2max, +9.1%; Pmax, +11.7%) cyclists, however, no time × visual impairment interaction effect was found (VO2max, p=0.467; Pmax, p=0.364). After training, VO2max (p=0.03), but not Pmax (p=0.13), was significantly greater in elite compared to sub-elite tandem cyclists. VI and PS tandem cyclists showed similar rates of improvement in VO2max and Pmax after 7-month training. VO2max was a significant determinant of success in tandem cycling. This is one of the first studies providing reference values for aerobic and anaerobic capacity in visually impaired cyclists. PMID:26834877

  17. Effect of voluntary hypocapnic hyperventilation on the metabolic response during Wingate anaerobic test.

    PubMed

    Fujii, Naoto; Tsuchiya, Sho-Ichiro; Tsuji, Bun; Watanabe, Kazuhito; Sasaki, Yosuke; Nishiyasu, Takeshi

    2015-09-01

    We evaluated whether hypocapnia achieved through voluntary hyperventilation diminishes the increases in oxygen uptake elicited by short-term (e.g., ~30 s) all-out exercise without affecting exercise performance. Nine subjects performed 30-s Wingate anaerobic tests (WAnT) in control and hypocapnia trials on separate days in a counterbalanced manner. During the 20-min rest prior to the 30-s WAnT, the subjects in the hypocapnia trial performed voluntary hyperventilation (minute ventilation = 31 L min(-1)), while the subjects in the control trial continued breathing spontaneously (minute ventilation = 14 L min(-1)). The hyperventilation in the hypocapnia trial reduced end-tidal CO2 pressure from 34.8 ± 2.5 mmHg at baseline rest to 19.3 ± 1.0 mmHg immediately before the 30-s WAnT. In the control trial, end-tidal CO2 pressure at baseline rest (35.9 ± 2.5 mmHg) did not differ from that measured immediately before the 30-s WAnT (35.9 ± 3.3 mmHg). Oxygen uptake during the 30-s WAnT was lower in the hypocapnia than the control trial (1.55 ± 0.52 vs. 1.95 ± 0.44 L min(-1)), while the postexercise peak blood lactate concentration was higher in the hypocapnia than control trial (10.4 ± 1.9 vs. 9.6 ± 1.9 mmol L(-1)). In contrast, there was no difference in the 5-s peak (842 ± 111 vs. 850 ± 107 W) or mean (626 ± 74 vs. 639 ± 80 W) power achieved during the 30-s WAnT between the control and hypocapnia trials. These results suggest that during short-period all-out exercise (e.g., 30-s WAnT), hypocapnia induced by voluntary hyperventilation reduces the aerobic metabolic rate without affecting exercise performance. This implies a compensatory elevation in the anaerobic metabolic rate.

  18. A life cycle approach to the management of household food waste - A Swedish full-scale case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstad, A., E-mail: anna.bernstad@chemeng.lth.se; Cour Jansen, J. la

    2011-08-15

    Research Highlights: > The comparison of three different methods for management of household food waste show that anaerobic digestion provides greater environmental benefits in relation to global warming potential, acidification and ozone depilation compared to incineration and composting of food waste. Use of produced biogas as car fuel provides larger environmental benefits compared to a use of biogas for heat and power production. > The use of produced digestate from the anaerobic digestion as substitution for chemical fertilizer on farmland provides avoidance of environmental burdens in the same ratio as the substitution of fossil fuels with produced biogas. > Sensitivitymore » analyses show that results are highly sensitive to assumptions regarding the environmental burdens connected to heat and energy supposedly substituted by the waste treatment. - Abstract: Environmental impacts from incineration, decentralised composting and centralised anaerobic digestion of solid organic household waste are compared using the EASEWASTE LCA-tool. The comparison is based on a full scale case study in southern Sweden and used input-data related to aspects such as source-separation behaviour, transport distances, etc. are site-specific. Results show that biological treatment methods - both anaerobic and aerobic, result in net avoidance of GHG-emissions, but give a larger contribution both to nutrient enrichment and acidification when compared to incineration. Results are to a high degree dependent on energy substitution and emissions during biological processes. It was seen that if it is assumed that produced biogas substitute electricity based on Danish coal power, this is preferable before use of biogas as car fuel. Use of biogas for Danish electricity substitution was also determined to be more beneficial compared to incineration of organic household waste. This is a result mainly of the use of plastic bags in the incineration alternative (compared to paper bags in the anaerobic) and the use of biofertiliser (digestate) from anaerobic treatment as substitution of chemical fertilisers used in an incineration alternative. Net impact related to GWP from the management chain varies from a contribution of 2.6 kg CO{sub 2}-eq/household and year if incineration is utilised, to an avoidance of 5.6 kg CO{sub 2}-eq/household and year if choosing anaerobic digestion and using produced biogas as car fuel. Impacts are often dependent on processes allocated far from the control of local decision-makers, indicating the importance of a holistic approach and extended collaboration between agents in the waste management chain.« less

  19. Does increasing active warm-up duration affect afternoon short-term maximal performance during Ramadan?

    PubMed

    Baklouti, Hana; Aloui, Asma; Chtourou, Hamdi; Briki, Walid; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    The purpose of this study was to examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the afternoon. Twelve healthy active men took part in the study. The experimental design consisted of four test sessions conducted at 5 p.m., before and during Ramadan, either with a 5-minute or a 15-minute warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. During each session, the subjects performed two vertical jump tests (squat jump and counter movement jump) for measurement of vertical jump height followed by a 30-second Wingate test for measurement of peak and mean power. Oral temperature was recorded at rest and after warming-up. Moreover, ratings of perceived exertion were obtained immediately after the Wingate test. Oral temperature was higher before Ramadan than during Ramadan at rest, and was higher after the 15-minute warm-up than the 5-minute warm-up both before and during Ramadan. In addition, vertical jump heights were not significantly different between the two warm-up conditions before and during Ramadan, and were lower during Ramadan than before Ramadan after both warm-up conditions. Peak and mean power were not significantly different between the two warm-up durations before Ramadan, but were significantly higher after the 5-minute warm-up than the 15-minute warm-up during Ramadan. Moreover, peak and mean power were lower during Ramadan than before Ramadan after both warm-up conditions. Furthermore, ratings of perceived exertion were higher after the 15-minute warm-up than the 5-minute warm-up only during Ramadan. The prolonged active warm-up has no effect on vertical jump height but impairs anaerobic power assessed during Ramadan in the afternoon.

  20. Does Increasing Active Warm-Up Duration Affect Afternoon Short-Term Maximal Performance during Ramadan?

    PubMed Central

    Baklouti, Hana; Aloui, Asma; Chtourou, Hamdi; Briki, Walid; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    Aim The purpose of this study was to examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the afternoon. Methods Twelve healthy active men took part in the study. The experimental design consisted of four test sessions conducted at 5 p.m., before and during Ramadan, either with a 5-minute or a 15-minute warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. During each session, the subjects performed two vertical jump tests (squat jump and counter movement jump) for measurement of vertical jump height followed by a 30-second Wingate test for measurement of peak and mean power. Oral temperature was recorded at rest and after warming-up. Moreover, ratings of perceived exertion were obtained immediately after the Wingate test. Results Oral temperature was higher before Ramadan than during Ramadan at rest, and was higher after the 15-minute warm-up than the 5-minute warm-up both before and during Ramadan. In addition, vertical jump heights were not significantly different between the two warm-up conditions before and during Ramadan, and were lower during Ramadan than before Ramadan after both warm-up conditions. Peak and mean power were not significantly different between the two warm-up durations before Ramadan, but were significantly higher after the 5-minute warm-up than the 15-minute warm-up during Ramadan. Moreover, peak and mean power were lower during Ramadan than before Ramadan after both warm-up conditions. Furthermore, ratings of perceived exertion were higher after the 15-minute warm-up than the 5-minute warm-up only during Ramadan. Conclusion The prolonged active warm-up has no effect on vertical jump height but impairs anaerobic power assessed during Ramadan in the afternoon. PMID:25646955

  1. Implementation of the anaerobic digestion model (ADM1) in the PHREEQC chemistry engine.

    PubMed

    Huber, Patrick; Neyret, Christophe; Fourest, Eric

    2017-09-01

    Anaerobic digestion is state-of-the-art technology to treat sludge and effluents from various industries. Modelling and optimisation of digestion operations can be advantageously performed using the anaerobic digestion model (ADM1) from the International Water Association. The ADM1, however, lacks a proper physico-chemical framework, which makes it difficult to consider wastewater of complex ionic composition and supersaturation phenomena. In this work, we present a direct implementation of the ADM1 within the PHREEQC chemistry engine. This makes it possible to handle ionic strength effects and ion-pairing. Thus, multiple mineral precipitation phenomena can be handled while resolving the ADM1. All these features can be accessed with very little programming effort, while retaining the full power and flexibility of PHREEQC. The distributed PHREEQC code can be easily interfaced with process simulation software for future plant-wide simulation of both wastewater and sludge treatment.

  2. Improving anaerobic and aerobic degradation by ultrasonic disintegration of biomass.

    PubMed

    Neis, Uwe; Nickel, Klaus; Lundén, Anna

    2008-11-01

    Biological cell lysis is known to be the rate-limiting step of anaerobic biosolids degradation. Due to the slow pace by which this reaction occurs, it is necessary to equip treatment plants with large digesters or alternatively incorporate technological aids. High-power ultrasound used to disintegrate bacterial cells has been utilized as a pre-treatment process prior to anaerobic digestion. Through this application, as seen on pilot- and full-scales, it is possible to attain up to 30% more biogas, an increase in VS-destruction of up to 30% and a reduced sludge mass for disposal. Utilizing ultrasound technology in aerobic applications is a new and innovative approach. Improved denitrification through a more readily available internal carbon source, and less excess sludge mass can be traced to the positive effects that sonication of sludge has on the overall biological wastewater treatment process. Reference full-scale installations suggest that the technology is both technically feasible and economically sound.

  3. The effects of polyethylene glycosylated creatine supplementation on anaerobic performance measures and body composition.

    PubMed

    Camic, Clayton L; Housh, Terry J; Zuniga, Jorge M; Traylor, Daniel A; Bergstrom, Haley C; Schmidt, Richard J; Johnson, Glen O; Housh, Dona J

    2014-03-01

    The purpose of this study was to examine the effects of 28 days of polyethylene glycosylated creatine (PEG-creatine) supplementation (1.25 and 2.50 g·d) on anaerobic performance measures (vertical and broad jumps, 40-yard dash, 20-yard shuttle run, and 3-cone drill), upper- and lower-body muscular strength and endurance (bench press and leg extension), and body composition. This study used a randomized, double-blind, placebo-controlled parallel design. Seventy-seven adult men (mean age ± SD, 22.1 ± 2.5 years; body mass, 81.7 ± 10.8 kg) volunteered to participate and were randomly assigned to a placebo (n = 23), 1.25 g·d of PEG-creatine (n = 27), or 2.50 g·d of PEG-creatine (n = 27) group. The subjects performed anaerobic performance measures, muscular strength (one-repetition maximum [1RM]), and endurance (80% 1RM) tests for bench press and leg extension, and underwater weighing for the determination of body composition at day 0 (baseline), day 14, and day 28. The results indicated that there were improvements (p < 0.0167) in vertical jump, 20-yard shuttle run, 3-cone drill, muscular endurance for bench press, and body mass for at least one of the PEG-creatine groups without changes for the placebo group. Thus, the present results demonstrated that PEG-creatine supplementation at 1.25 or 2.50 g·d had an ergogenic effect on lower-body vertical power, agility, change-of-direction ability, upper-body muscular endurance, and body mass.

  4. Resource recovery and epidemiology of anaerobic wastewater treatment process in a controlled ecological life support system

    NASA Technical Reports Server (NTRS)

    Li, Ku-Yen; Hunt, Madelyn D.

    1995-01-01

    The results of work accomplished under two different areas: (1) Resource Recovery of an Anaerobic Wastewater Treatment process, and (2) Epidemiological Study of an Anaerobic Wastewater Treatment Process are documented. The first part of the work was to set up and test three anaerobic digesters and then run these three digesters with a NASA-simulated wastewater. The second part of the work was to use a multi-drug resistant strain of Salmonella choleraesuis as the indicator bacteria for the epidemiological study. Details of these two parts can be found in two master's theses and are described in Sections 3 and 4 of this report. Several important results condensed from these two parts are summarized in Section 2.

  5. Effect of heating strategy on power consumption and performance of a pilot plant anaerobic digester.

    PubMed

    Espinosa-Solares, Teodoro; Valle-Guadarrama, Salvador; Bombardiere, John; Domaschko, Max; Easter, Michael

    2009-05-01

    The effect of heating strategy on power consumption and performance of a pilot plant anaerobic digester treating chicken litter, under thermophilic conditions, has been studied. Heating strategy was evaluated using three different spans (0.2 degrees C, 0.6 degrees C, and 1.0 degree C) for triggering the temperature control system from target temperature (56.7 degrees C). The hydraulic retention time in the pilot plant digester was in the range of 32 to 37 days, varying the total solids concentration fed from 5% to 6%. The results showed that under the experimental conditions, heating was the most energy-demanding process with 95.5% of the energy used. Increments up to 7.5% and 3.8%, respectively, on mechanical and heating power consumption, were observed as the span, for triggering the temperature control system from target temperature, was increased. Under the experimental conditions studied here, an increment of 30.6% on the global biodigester performance index was observed when a span of 1.0 degree C was compared to the one of 0.2 degrees C.

  6. Effects of phase vector and history extension on prediction power of adaptive-network based fuzzy inference system (ANFIS) model for a real scale anaerobic wastewater treatment plant operating under unsteady state.

    PubMed

    Perendeci, Altinay; Arslan, Sever; Tanyolaç, Abdurrahman; Celebi, Serdar S

    2009-10-01

    A conceptual neural fuzzy model based on adaptive-network based fuzzy inference system, ANFIS, was proposed using available input on-line and off-line operational variables for a sugar factory anaerobic wastewater treatment plant operating under unsteady state to estimate the effluent chemical oxygen demand, COD. The predictive power of the developed model was improved as a new approach by adding the phase vector and the recent values of COD up to 5-10 days, longer than overall retention time of wastewater in the system. History of last 10 days for COD effluent with two-valued phase vector in the input variable matrix including all parameters had more predictive power. History of 7 days with two-valued phase vector in the matrix comprised of only on-line variables yielded fairly well estimations. The developed ANFIS model with phase vector and history extension has been able to adequately represent the behavior of the treatment system.

  7. Determination of Anaerobic Threshold by Heart Rate or Heart Rate Variability using Discontinuous Cycle Ergometry.

    PubMed

    Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan

    The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.

  8. Sense of rhythm does not differentiate professional hurdlers from non-athletes.

    PubMed

    Skowronek, Tomasz; Słomka, Kajetan; Juras, Grzegorz; Szade, Bartlomiej

    2013-08-01

    The importance of rhythm and specific endurance capabilities were examined in the technical skill and performance of hurdle runners. Additionally, interaction effects among rhythm, anaerobic fitness, and body constitution were analyzed. Seven 18-year-old members of the Polish Junior National Team in 110 m hurdles and 8 age-matched controls who were non-athletes participated. Movement coordination tests (rhythm and differentiation tests) and an anaerobic fitness test were performed. There were no statistically significant differences between the athletes and the control group on the coordination or rhythm test variables. No support was found for the hypothesis that a hurdler's timing ability influences performance.

  9. Efficient Anaerobic Digestion of Microalgae Biomass: Proteins as a Key Macromolecule.

    PubMed

    Magdalena, Jose Antonio; Ballesteros, Mercedes; González-Fernandez, Cristina

    2018-05-06

    Biogas generation is the least complex technology to transform microalgae biomass into bioenergy. Since hydrolysis has been pointed out as the rate limiting stage of anaerobic digestion, the main challenge for an efficient biogas production is the optimization of cell wall disruption/hydrolysis. Among all tested pretreatments, enzymatic treatments were demonstrated not only very effective in disruption/hydrolysis but they also revealed the impact of microalgae macromolecular composition in the anaerobic process. Although carbohydrates have been traditionally recognized as the polymers responsible for the low microalgae digestibility, protease addition resulted in the highest organic matter solubilization and the highest methane production. However, protein solubilization during the pretreatment can result in anaerobic digestion inhibition due to the release of large amounts of ammonium nitrogen. The possible solutions to overcome these negative effects include the reduction of protein biomass levels by culturing the microalgae in low nitrogen media and the use of ammonia tolerant anaerobic inocula. Overall, this review is intended to evidence the relevance of microalgae proteins in different stages of anaerobic digestion, namely hydrolysis and methanogenesis.

  10. High-Intensity Intermittent Training Positively Affects Aerobic and Anaerobic Performance in Judo Athletes Independently of Exercise Mode

    PubMed Central

    Franchini, Emerson; Julio, Ursula F.; Panissa, Valéria L. G.; Lira, Fábio S.; Gerosa-Neto, José; Branco, Braulio H. M.

    2016-01-01

    Purpose: The present study investigated the effects of high-intensity intermittent training (HIIT) on lower- and upper-body graded exercise and high-intensity intermittent exercise (HIIE, four Wingate bouts) performance, and on physiological and muscle damage markers responses in judo athletes. Methods: Thirty-five subjects were randomly allocated to a control group (n = 8) or to one of the following HIIT groups (n = 9 for each) and tested pre- and post-four weeks (2 training d·wk−1): (1) lower-body cycle-ergometer; (2) upper-body cycle-ergometer; (3) uchi-komi (judo technique entrance). All HIIT were constituted by two blocks of 10 sets of 20 s of all out effort interspersed by 10 s set intervals and 5-min between blocks. Results: For the upper-body group there was an increase in maximal aerobic power in graded upper-body exercise test (12.3%). The lower-body group increased power at onset blood lactate in graded upper-body exercise test (22.1%). The uchi-komi group increased peak power in upper- (16.7%) and lower-body (8.5%), while the lower-body group increased lower-body mean power (14.2%) during the HIIE. There was a decrease in the delta blood lactate for the uchi-komi training group and in the third and fourth bouts for the upper-body training group. Training induced testosterone-cortisol ratio increased in the lower-body HIIE for the lower-body (14.9%) and uchi-komi (61.4%) training groups. Conclusion: Thus, short-duration low-volume HIIT added to regular judo training was able to increase upper-body aerobic power, lower- and upper-body HIIE performance. PMID:27445856

  11. Changes in selected physical, motor performance and anthropometric components of university-level rugby players after one microcycle of a combined rugby conditioning and plyometric training program.

    PubMed

    Pienaar, Cindy; Coetzee, Ben

    2013-02-01

    The purpose of this study was to determine the effects of a microcycle (4 weeks) combined rugby conditioning plyometric compared with a nonplyometric rugby conditioning program on selected physical and motor performance components and anthropometric measurements of university-level rugby players. Players (18.94 ± 0.40 years) were assigned to either a control (n = 16) or experimental group (n = 19) from the U/19 rugby teams of the North-West University (South Africa). Twenty-six direct and indirect anthropometric measurements were taken, and the players performed a battery of 5 physical and motor performance tests before and after a microcycle (4 week) combined rugby conditioning plyometric (experimental group) and a nonplyometric rugby conditioning program (control group). The dependent t-test results showed that the control group's upper-body explosive power decreased significantly, whereas the stature, skeletal mass, and femur breadth increased significantly from pre- to posttesting. The experimental group showed significant increases in wrist breadth, speed over 20 m, agility, and power and work measurements of the Wingate anaerobic test (WAnT). Despite these results, the independent t-test revealed that speed over 20 m, average power output at 20 seconds, relative work of the WAnT, and agility were the only components of the experimental group that improved significantly more than the control group. A microcycle combined rugby conditioning plyometric program therefore leads to significantly bigger changes in selected physical and motor performance components of university-level rugby players than a nonplyometric rugby conditioning program alone. Based on these findings, coaches and sport scientists should implement 3 weekly combined rugby conditioning plyometric programs in rugby players' training regimens to improve the players' speed, agility, and power.

  12. Dissociating external power from intramuscular exercise intensity during intermittent bilateral knee‐extension in humans

    PubMed Central

    Davies, Matthew J.; Benson, Alan P.; Cannon, Daniel T.; Marwood, Simon; Kemp, Graham J.; Rossiter, Harry B.

    2017-01-01

    Key points Continuous high‐intensity constant‐power exercise is unsustainable, with maximal oxygen uptake (V˙O2 max ) and the limit of tolerance attained after only a few minutes.Performing the same power intermittently reduces the O2 cost of exercise and increases tolerance. The extent to which this dissociation is reflected in the intramuscular bioenergetics is unknown.We used pulmonary gas exchange and 31P magnetic resonance spectroscopy to measure whole‐body V˙O2, quadriceps phosphate metabolism and pH during continuous and intermittent exercise of different work:recovery durations.Shortening the work:recovery durations (16:32 s vs. 32:64 s vs. 64:128 s vs. continuous) at a work rate estimated to require 110% peak aerobic power reduced V˙O2, muscle phosphocreatine breakdown and muscle acidification, eliminated the glycolytic‐associated contribution to ATP synthesis, and increased exercise tolerance.Exercise intensity (i.e. magnitude of intramuscular metabolic perturbations) can be dissociated from the external power using intermittent exercise with short work:recovery durations. Abstract Compared with work‐matched high‐intensity continuous exercise, intermittent exercise dissociates pulmonary oxygen uptake (V˙O2) from the accumulated work. The extent to which this reflects differences in O2 storage fluctuations and/or contributions from oxidative and substrate‐level bioenergetics is unknown. Using pulmonary gas‐exchange and intramuscular 31P magnetic resonance spectroscopy, we tested the hypotheses that, at the same power: ATP synthesis rates are similar, whereas peak V˙O2 amplitude is lower in intermittent vs. continuous exercise. Thus, we expected that: intermittent exercise relies less upon anaerobic glycolysis for ATP provision than continuous exercise; shorter intervals would require relatively greater fluctuations in intramuscular bioenergetics than in V˙O2 compared to longer intervals. Six men performed bilateral knee‐extensor exercise (estimated to require 110% peak aerobic power) continuously and with three different intermittent work:recovery durations (16:32, 32:64 and 64:128 s). Target work duration (576 s) was achieved in all intermittent protocols; greater than continuous (252 ± 174 s; P < 0.05). Mean ATP turnover rate was not different between protocols (∼43 mm min−1 on average). However, the intramuscular phosphocreatine (PCr) component of ATP generation was greatest (∼30 mm min−1), and oxidative (∼10 mm min−1) and anaerobic glycolytic (∼1 mm min−1) components were lowest for 16:32 and 32:64 s intermittent protocols, compared to 64:128 s (18 ± 6, 21 ± 10 and 10 ± 4 mm min−1, respectively) and continuous protocols (8 ± 6, 20 ± 9 and 16 ± 14 mm min−1, respectively). As intermittent work duration increased towards continuous exercise, ATP production relied proportionally more upon anaerobic glycolysis and oxidative phosphorylation, and less upon PCr breakdown. However, performing the same high‐intensity power intermittently vs. continuously reduced the amplitude of fluctuations in V˙O2 and intramuscular metabolism, dissociating exercise intensity from the power output and work done. PMID:28776675

  13. Fate of estradiol and testosterone in anaerobic lagoon digestors

    USDA-ARS?s Scientific Manuscript database

    Laboratory-scale lagoon digestors were constructed, and the fate of 14C-labelled 17ß-estradiol (E2) and testosterone (Test) were monitored for 42 d anaerobically under biological and sterile conditions. Hormone levels decreased in the liquid layer and increased in the sludge with time. At 42 d, 16-2...

  14. Treatment of melanoidin wastewater by anaerobic digestion and coagulation.

    PubMed

    Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe

    2015-01-01

    Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.

  15. [Distribution of anaerobes in periodontal abscess and its resistance to antibiotics].

    PubMed

    He, Jun-lin; Yu, Li-ying; Chen, Jia-zhen

    2012-12-01

    To isolate and culture the predominant anaerobes from the periodontal abscesses, and to test the antibiotic susceptibility and drug resistant genes of the strains. The isolated strains were identified by both API20A biochemical method and polymerase chain reaction (PCR) method. The antibiotic susceptibility test was performed by agar dilution method. The resistant genes of the drug-resistant strains obtained were screened by PCR. The anaerobes were detected in 48% (28/58) of the samples and Prevotella melaninogenica (Pm) was mostly identified in 43% (12/28). API20A biochemical method had 82% (23/28) agreement with the 16SrRNA method in identification rate. Anaerobes were resistant to metronidazole, clindamycin and cefmetazole. The erythromycin-resistant methylase genes F (ermF) gene was detected in three of eight clindamycin resistant strains. None of them was found coded on bacterial plasmids. However, no metronidazole resistant gene was detected on drug resistant strains. Pm was the predominant species dectected in the periodontal abscess of the patients. The antibiotic agents should be used based on the genotypes and general condition of the patients.

  16. Techno-economic evaluation of stillage treatment with anaerobic digestion in a softwood-to-ethanol process.

    PubMed

    Barta, Zsolt; Reczey, Kati; Zacchi, Guido

    2010-09-15

    Replacing the energy-intensive evaporation of stillage by anaerobic digestion is one way of decreasing the energy demand of the lignocellulosic biomass to the ethanol process. The biogas can be upgraded and sold as transportation fuel, injected directly into the gas grid or be incinerated on-site for combined heat and power generation. A techno-economic evaluation of the spruce-to-ethanol process, based on SO2-catalysed steam pretreatment followed by simultaneous saccharification and fermentation, has been performed using the commercial flow-sheeting program Aspen Plus™. Various process configurations of anaerobic digestion of the stillage, with different combinations of co-products, have been evaluated in terms of energy efficiency and ethanol production cost versus the reference case of evaporation. Anaerobic digestion of the stillage showed a significantly higher overall energy efficiency (87-92%), based on the lower heating values, than the reference case (81%). Although the amount of ethanol produced was the same in all scenarios, the production cost varied between 4.00 and 5.27 Swedish kronor per litre (0.38-0.50 euro/L), including the reference case. Higher energy efficiency options did not necessarily result in lower ethanol production costs. Anaerobic digestion of the stillage with biogas upgrading was demonstrated to be a favourable option for both energy efficiency and ethanol production cost. The difference in the production cost of ethanol between using the whole stillage or only the liquid fraction in anaerobic digestion was negligible for the combination of co-products including upgraded biogas, electricity and district heat.

  17. Techno-economic evaluation of stillage treatment with anaerobic digestion in a softwood-to-ethanol process

    PubMed Central

    2010-01-01

    Background Replacing the energy-intensive evaporation of stillage by anaerobic digestion is one way of decreasing the energy demand of the lignocellulosic biomass to the ethanol process. The biogas can be upgraded and sold as transportation fuel, injected directly into the gas grid or be incinerated on-site for combined heat and power generation. A techno-economic evaluation of the spruce-to-ethanol process, based on SO2-catalysed steam pretreatment followed by simultaneous saccharification and fermentation, has been performed using the commercial flow-sheeting program Aspen Plus™. Various process configurations of anaerobic digestion of the stillage, with different combinations of co-products, have been evaluated in terms of energy efficiency and ethanol production cost versus the reference case of evaporation. Results Anaerobic digestion of the stillage showed a significantly higher overall energy efficiency (87-92%), based on the lower heating values, than the reference case (81%). Although the amount of ethanol produced was the same in all scenarios, the production cost varied between 4.00 and 5.27 Swedish kronor per litre (0.38-0.50 euro/L), including the reference case. Conclusions Higher energy efficiency options did not necessarily result in lower ethanol production costs. Anaerobic digestion of the stillage with biogas upgrading was demonstrated to be a favourable option for both energy efficiency and ethanol production cost. The difference in the production cost of ethanol between using the whole stillage or only the liquid fraction in anaerobic digestion was negligible for the combination of co-products including upgraded biogas, electricity and district heat. PMID:20843330

  18. Anaerobic-aerobic treatment of purified terephthalic acid (PTA) effluent; a techno-economic alternative to two-stage aerobic process.

    PubMed

    Pophali, G R; Khan, R; Dhodapkar, R S; Nandy, T; Devotta, S

    2007-12-01

    This paper addresses the treatment of purified terephthalic acid (PTA) effluent using anaerobic and aerobic processes. Laboratory studies were carried out on flow proportionate composite wastewater generated from the manufacturing of PTA. An activated sludge process (ASP-two stage and single stage) and an upflow anaerobic fixed film fixed bed reactor (AFFFBR) were used, individually and in combination. The performance of a full-scale ETP under existing operating conditions was also studied. Full scale ETP studies revealed that the treatment of PTA effluent using a two-stage ASP alone does not meet treated effluent quality within the prescribed Indian Standards. The biomass produced in the two stage ASP was very viscous and fluffy and the sludge volume index (SVI) was very high (200-450 ml/g). However, pretreatment of PTA effluent using an upflow AFFFBR ensured substantial reduction in BOD (63%) and COD (62%) with recovery of biogas at 1.8-1.96 l/l effluent treated at a volumetric loading rate (VLR) 4-5 kg COD/m(3) d. The methane content in the biogas varied between 55% and 60%. The pretreated effluent from the upflow AFFFBR was then treated through a single stage ASP. The biomass produced in the ASP after anaerobic treatment had very good settlability (SVI: 75-90 ml/g) as compared to the two stage ASP and the treated effluent quality with respect to BOD, COD and SS was within the prescribed Indian Standards. The alternative treatment process comprising an upflow AFFFBR and a single stage ASP ensured net power saving of 257 kW and in addition generated 442 kW of power through the AFFFBR.

  19. Predicting High-Power Performance in Professional Cyclists.

    PubMed

    Sanders, Dajo; Heijboer, Mathieu; Akubat, Ibrahim; Meijer, Kenneth; Hesselink, Matthijs K

    2017-03-01

    To assess if short-duration (5 to ~300 s) high-power performance can accurately be predicted using the anaerobic power reserve (APR) model in professional cyclists. Data from 4 professional cyclists from a World Tour cycling team were used. Using the maximal aerobic power, sprint peak power output, and an exponential constant describing the decrement in power over time, a power-duration relationship was established for each participant. To test the predictive accuracy of the model, several all-out field trials of different durations were performed by each cyclist. The power output achieved during the all-out trials was compared with the predicted power output by the APR model. The power output predicted by the model showed very large to nearly perfect correlations to the actual power output obtained during the all-out trials for each cyclist (r = .88 ± .21, .92 ± .17, .95 ± .13, and .97 ± .09). Power output during the all-out trials remained within an average of 6.6% (53 W) of the predicted power output by the model. This preliminary pilot study presents 4 case studies on the applicability of the APR model in professional cyclists using a field-based approach. The decrement in all-out performance during high-intensity exercise seems to conform to a general relationship with a single exponential-decay model describing the decrement in power vs increasing duration. These results are in line with previous studies using the APR model to predict performance during brief all-out trials. Future research should evaluate the APR model with a larger sample size of elite cyclists.

  20. Effects of substrate to inoculum ratio on the biochemical methane potential of piggery slaughterhouse wastes.

    PubMed

    Yoon, Young-Man; Kim, Seung-Hwan; Shin, Kook-Sik; Kim, Chang-Hyun

    2014-04-01

    The aim of this study was to assess the effect of substrate to inoculum ratio (S/I ratio) on the biochemical methane potential (BMP) and anaerobic biodegradability (Ddeg) of different piggery slaughterhouse wastes, such as piggery blood, intestine residue, and digestive tract content. These wastes were sampled from a piggery slaughterhouse located in Kimje, South Korea. Cumulative methane production curves for the wastes were obtained from the anaerobic batch fermentation having different S/I ratios of 0.1, 0.5, 1.0, and 1.5. BMP and anaerobic biodegradabilities (Ddeg) of the wastes were calculated from cumulative methane production data for the tested conditions. At the lowest S/I ration of 0.1, BMPs of piggery blood, intestine residue, and digestive tract content were determined to be 0.799, 0.848, and 1.076 Nm(3) kg(-1)-VSadded, respectively, which were above the theoretical methane potentials of 0.539, 0.644, and 0.517 Nm(3) kg(-1)-VSadded for blood, intestine residue, and digestive tract content, respectively. However, BMPs obtained from the higher S/I ratios of 0.5, 1.0, and 1.5 were within the theoretical range for all three types of waste and were not significantly different for the different S/I ratios tested. Anaerobic biodegradabilities calculated from BMP data showed a similar tendency. These results imply that, for BMP assay in an anaerobic reactor, the S/I ratio of anaerobic reactor should be above 0.1 and the inoculum should be sufficiently stabilized to avoid further degradation during the assay.

  1. Effects of Substrate to Inoculum Ratio on the Biochemical Methane Potential of Piggery Slaughterhouse Wastes

    PubMed Central

    Yoon, Young-Man; Kim, Seung-Hwan; Shin, Kook-Sik; Kim, Chang-Hyun

    2014-01-01

    The aim of this study was to assess the effect of substrate to inoculum ratio (S/I ratio) on the biochemical methane potential (BMP) and anaerobic biodegradability (Ddeg) of different piggery slaughterhouse wastes, such as piggery blood, intestine residue, and digestive tract content. These wastes were sampled from a piggery slaughterhouse located in Kimje, South Korea. Cumulative methane production curves for the wastes were obtained from the anaerobic batch fermentation having different S/I ratios of 0.1, 0.5, 1.0, and 1.5. BMP and anaerobic biodegradabilities (Ddeg) of the wastes were calculated from cumulative methane production data for the tested conditions. At the lowest S/I ration of 0.1, BMPs of piggery blood, intestine residue, and digestive tract content were determined to be 0.799, 0.848, and 1.076 Nm3 kg−1-VSadded, respectively, which were above the theoretical methane potentials of 0.539, 0.644, and 0.517 Nm3 kg−1-VSadded for blood, intestine residue, and digestive tract content, respectively. However, BMPs obtained from the higher S/I ratios of 0.5, 1.0, and 1.5 were within the theoretical range for all three types of waste and were not significantly different for the different S/I ratios tested. Anaerobic biodegradabilities calculated from BMP data showed a similar tendency. These results imply that, for BMP assay in an anaerobic reactor, the S/I ratio of anaerobic reactor should be above 0.1 and the inoculum should be sufficiently stabilized to avoid further degradation during the assay. PMID:25049994

  2. Performance of Healthy Braced Participants During Aerobic and Anaerobic Capacity Tasks

    PubMed Central

    Rishiraj, Neetu; Taunton, Jack E.; Niven, Brian; Lloyd-Smith, Robert; Regan, William; Woollard, Robert

    2011-01-01

    Context: Knee braces were introduced in sports approximately 30 years ago. However, the effects of a functional knee brace (FKB) on aerobic and anaerobic performance after fatigue are unknown. Objective: To investigate whether FKB use in noninjured participants hindered performance during aerobic (Léger beep test) and anaerobic (repeated high-intensity shuttle test [RHIST]) tasks. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Twenty-seven healthy male provincial and national basketball and field hockey athletes (age = 19.4 ± 3.0 years, range, 17–26 years; height = 182.6 ± 6.8 cm, range, 168–196 cm; mass = 80.0 ± 9.1 kg, range, 66–108 kg). Interventions : Each participant was provided a custom-fitted FKB and performed 5 nonbraced (NBR) testing sessions over 3 days, followed by 5 braced (BR) testing sessions over 3 days, for a total of 17.5 hours of testing per condition. During each testing session, participants performed 1 trial of the Léger beep test and 1 trial of the RHIST in each condition. Main Outcome Measure(s): Predicted maximal oxygen consumption (V˙o2max) and time performance measures were recorded for each NBR and BR trial. Results: Initial performance levels were lower for BR than NBR for both the Léger beep test (BR = 44.3 mL/kg/min, NBR = 47.3 mL/kg/min; F1,26 = 8.726; P = .007) and the RHIST (BR = 16.5 seconds, NBR = 16.2 seconds; F1,26 = 13.98, P = .001). However, with continued FKB use, the aerobic performance measure remained higher for only the first 2 BR testing sessions (NBR = 46.9 mL/kg/min, BR = 42.4 mL/kg/min; F3.0,79.8 = 4.95, P = .003). For the anaerobic test, no performance difference was noted between the testing conditions (NBR = 16.2 seconds, BR = 16.4 seconds; P = .7), whereas fatigue levels were lower during BR testing sessions (NBR = 33%, BR = 31%). After 14.0 hours of FKB use, performance levels were almost equal between the testing conditions (NBR = 47.6 mL/kg/min, BR = 46.1 mL/kg/min). Conclusions: We found an initial decrement in performance when the FKB was used during an aerobic or anaerobic task. However, after 14.0 hours of FKB use, accommodation to the FKB was possible. PMID:21944071

  3. Stress hormone epinephrine (adrenaline) and norepinephrine (noradrenaline) effects on the anaerobic bacteria.

    PubMed

    Boyanova, Lyudmila

    2017-04-01

    Microbial endocrinology is a relatively new research area that already encompasses the anaerobes. Stress hormones, epinephrine and norepinephrine, can affect the growth of anaerobic bacteria such as Fusobacterium nucleatum, Prevotella spp., Porhyromonas spp., Tanerella forsythia and Propionibacterium acnes and can increase virulence gene expression, iron acquisition and many virulence factors of some anaerobic species such as Clostridium perfringens, Porphyromonas gingivalis and Brachyspira pilosicoli. Epinephrine and norepinephrine effects can lead to a growth increase or decrease, or no effect on the growth of the anaerobes. The effects are species-specific and perhaps strain-specific. Discrepancies in the results of some studies can be due to the different methods and media used, catecholamine concentrations, measurement techniques and the low number of strains tested. Biological effects of the stress hormones on the anaerobes may range from halitosis and a worsening of periodontal diseases to tissue damages and atherosclerotic plaque ruptures. Optimizations of the research methods and a detailed assessment of the catecholamine effects in conditions mimicking those in affected organs and tissues, as well as the effects on the quorum sensing and virulence of the anaerobes and the full spectrum of biological consequences of the effects are interesting topics for further evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Time to Exhaustion at the VO2max Velocity in Swimming: A Review

    PubMed Central

    Fernandes, Ricardo J.; Vilas-Boas, J. Paulo

    2012-01-01

    The aim of this study was to present a review on the time to exhaustion at the minimum swimming velocity corresponding to maximal oxygen consumption (TLim-vVO2max). This parameter is critical both for the aerobic power and the lactate tolerance bioenergetical training intensity zones, being fundamental to characterize it, and to point out its main determinants. The few number of studies conducted in this topic observed that swimmers were able to maintain an exercise intensity corresponding to maximal aerobic power during 215 to 260 s (elite swimmers), 230 to 260 s (high level swimmers) and 310 to 325 s (low level swimmers), and no differences between genders were reported. TLim-vVO2max main bioenergetic and functional determinants were swimming economy and VO2 slow component (direct relationship), and vVO2max, velocity at anaerobic threshold and blood lactate production (inverse relationship); when more homogeneous groups of swimmers were analysed, the inverse correlation value between TLim-vVO2max and vVO2max was not so evident. In general, TLim-vVO2max was not related to VO2max. TLim-vVO2max seems also to be influenced by stroking parameters, with a direct relationship to stroke length and stroke index, and an inverse correlation with stroke rate. Assessing TLim-vVO2max, together with the anaerobic threshold and the biomechanical general parameters, will allow a larger spectrum of testing protocols application, helping to build more objective and efficient training programs. PMID:23486651

  5. Antimicrobial susceptibility of clinically isolated anaerobic bacteria in a University Hospital Centre Split, Croatia in 2013.

    PubMed

    Novak, Anita; Rubic, Zana; Dogas, Varja; Goic-Barisic, Ivana; Radic, Marina; Tonkic, Marija

    2015-02-01

    Anaerobic bacteria play a significant role in many endogenous polymicrobial infections. Since antimicrobial resistance among anaerobes has increased worldwide, it is useful to provide local susceptibility data to guide empirical therapy. The present study reports recent data on the susceptibility of clinically relevant anaerobes in a University Hospital Centre (UHC) Split, Croatia. A total of 63 Gram-negative and 59 Gram-positive anaerobic clinical isolates from various body sites were consecutively collected from January to December 2013. Antimicrobial susceptibility testing was performed using standardized methods and interpreted using EUCAST criteria. Patient's clinical and demographic data were recorded by clinical microbiologist. Among 35 isolates of Bacteroides spp., 97.1% were resistant to penicillin (PCN), 5.7% to amoxicillin/clavulanic acid (AMC), 8.6% to piperacillin/tazobactam (TZP), 29.0% to clindamycin (CLI) and 2.9% to metronidazole (MZ). Percentages of susceptible strains to imipenem (IPM), meropenem (MEM) and ertapenem (ETP) were 94.3. Resistance of other Gram-negative bacilli was 76.0% to PCN, 8.0% to AMC, 12.0% to TZP, 28.0% to CLI and 8% to MZ. All other Gram-negative strains were fully susceptible to MEM and ETP, while 96.0% were susceptible to IPM. Clostridium spp. isolates were 100% susceptible to all tested antibiotics except to CLI (two of four tested isolates were resistant). Propionibacterium spp. showed resistance to CLI in 4.3%, while 100% were resistant to MZ. Among other Gram-positive bacilli, 18.2% were resistant to PCN, 9.1% to CLI and 54.5% to MZ, while 81.8% of isolates were susceptible to carbapenems. Gram-positive cocci were 100% susceptible to all tested antimicrobials except to MZ, where 28.6% of resistant strains were recorded. Abdomen was the most common source of isolates (82.5%). The most prevalent types of infection were abscess (22.1%), sepsis (14.8%), appendicitis (13.9%) and peritonitis (6.6%). Twenty four patients (19.7%) received empiric antimicrobial therapy. One hundred and one patients (82.8%) had polymicrobial aerobic/anaerobic isolates cultivated from the same specimens. Almost all aerobic bacteria were of endogenous origin and showed fully susceptible antimicrobial profile; only 8.7% (9/104) were multiresistant and considered as hospital acquired. Based on our findings, β-lactam/β-lactamase inhibitor combinations and metronidazole remain useful antimicrobials for empiric treatment of anaerobic infections, while carbapenems should be reserved for situations were multidrug resistant, aerobic or facultative Gram-negative bacteria are expected. However, a certain percentage of resistant isolates were observed for each of these agents. Therefore, periodic resistance surveillance in anaerobes is highly recommended in order to guide empirical therapy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Ultrasonic waste activated sludge disintegration for improving anaerobic stabilization.

    PubMed

    Tiehm, A; Nickel, K; Zellhorn, M; Neis, U

    2001-06-01

    The pretreatment of waste activated sludge by ultrasonic disintegration was studied in order to improve the anaerobic sludge stabilization. The ultrasound frequency was varied within a range from 41 to 3217 kHz. The impact of different ultrasound intensities and treatment times was examined. Sludge disintegration was most significant at low frequencies. Low-frequency ultrasound creates large cavitation bubbles which upon collapse initiate powerful jet streams exerting strong shear forces in the liquid. The decreasing sludge disintegration efficiency observed at higher frequencies was attributed to smaller cavitation bubbles which do not allow the initiation of such strong shear forces. Short sonication times resulted in sludge floc deagglomeration without the destruction of bacteria cells. Longer sonication brought about the break-up of cell walls, the sludge solids were distintegrated and dissolved organic compounds were released. The anaerobic digestion of waste activated sludge following ultrasonic pretreatment causing microbial cell lysis was significantly improved. There was an increase in the volatile solids degradation as well as an increase in the biogas production. The increase in digestion efficiency was proportional to the degree of sludge disintegration. To a lesser degree the deagglomeration of sludge flocs also augmented the anaerobic volatile solids degradation.

  7. Energy self-sufficient sewage wastewater treatment plants: is optimized anaerobic sludge digestion the key?

    PubMed

    Jenicek, P; Kutil, J; Benes, O; Todt, V; Zabranska, J; Dohanyos, M

    2013-01-01

    The anaerobic digestion of primary and waste activated sludge generates biogas that can be converted into energy to power the operation of a sewage wastewater treatment plant (WWTP). But can the biogas generated by anaerobic sludge digestion ever completely satisfy the electricity requirements of a WWTP with 'standard' energy consumption (i.e. industrial pollution not treated, no external organic substrate added)? With this question in mind, we optimized biogas production at Prague's Central Wastewater Treatment Plant in the following ways: enhanced primary sludge separation; thickened waste activated sludge; implemented a lysate centrifuge; increased operational temperature; improved digester mixing. With these optimizations, biogas production increased significantly to 12.5 m(3) per population equivalent per year. In turn, this led to an equally significant increase in specific energy production from approximately 15 to 23.5 kWh per population equivalent per year. We compared these full-scale results with those obtained from WWTPs that are already energy self-sufficient, but have exceptionally low energy consumption. Both our results and our analysis suggest that, with the correct optimization of anaerobic digestion technology, even WWTPs with 'standard' energy consumption can either attain or come close to attaining energy self-sufficiency.

  8. Toxicity of nonylphenol diethoxylate in lab-scale anaerobic digesters.

    PubMed

    Bozkurt, Hande; Sanin, F Dilek

    2014-06-01

    Nonylphenol compounds have high commercial, industrial and domestic uses owing to their surface active properties. In addition to their toxic, carcinogenic and persistent characteristics; they have drawn the attention of scientists lately due to their endocrine disrupting properties. Their widespread use and disposal cause them to enter wastewater treatment systems at high concentrations. Since they are highly persistent and hydrophobic, they accumulate mostly on sludge. In this study using Anaerobic Toxicity Assay (ATA) tests, the toxicity of a model nonylphenol compound, nonylphenol diethoxylate (NP2EO), for anaerobic digestion of sludge was determined. The test bottles were dosed with NP2EO in acetone, with concentrations ranging from 1 mg L(-1) to 30 mg L(-1). During the tests, gas productions and compositions in terms of methane and carbon dioxide were monitored. To be able to judge about the fate, the target compounds were extracted from water and sludge and analyzed using GC/MS. The sludge samples used for assembling the reactors were found to contain NP and NP1EO but no NP2EO. After the assay was completed, all the NP2EO spiked into the live reactors was found to disappear. The increase seen in NP1EO and NP and further accumulation of NP in the system, indicated the conversion of NP2EO to these metabolites. On the other hand, no conversion was observed in abiotic reactors. Inhibition of NP2EO for anaerobic microorganisms was not observed throughout the tests considering the biogas production of the test reactors in comparison to the control reactors. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Transport, fate, and long-term impacts of metal oxide nanoparticles on the stability of an anaerobic methanogenic system with anaerobic granular sludge.

    PubMed

    Li, Huiting; Cui, Fuyi; Liu, Zhiquan; Li, Dapeng

    2017-06-01

    The fate and long-term effect of different metal oxide (TiO 2 , CuO and ZnO) nanoparticles (NPs) on anaerobic granular sludge (AGS) was evaluated in an anaerobic methanogenic system. Operation stability and structural characteristics of the granules were compared, the metabolism changes in the microbial community were quantified, and NPs fate were investigated. CuO NPs had greatest toxic effect on AGS after extended exposure, whereas ZnO NPs benefited methanogenesis temporarily (no more than 5d). The inhibition on AGS caused by NPs varied due to the unique structure of AGS and different toxic mechanism. Structural changes of AGS provided new evidence that tested NPs have different toxicity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Metabolic Power in Team Sports - Part 2: Aerobic and Anaerobic Energy Yields.

    PubMed

    Osgnach, Cristian; di Prampero, Pietro Enrico

    2018-06-14

    A previous approach to estimate the time course of instantaneous metabolic power and O 2 consumption in team sports has been updated to assess also energy expenditure against air resistance and to identify walking and running separately. Whole match energy expenditure turned out ≈14% smaller than previously obtained, the fraction against the air resistance amounting to ≈2% of the total. Estimated net O 2 consumption and overall energy expenditure are fairly close to those measured by means of a portable metabolic cart; the average difference, after a 45 min exercise period of variable intensity and mode, amounting to ≈10%. Aerobic and anaerobic energy yields, metabolic power, energy expenditure and duration of High (HI) and Low (LI) intensity bouts can also be estimated. Indeed, data on 497 soccer players during the 2014/2015 Italian "Serie A" show that the number of HI efforts decreased from the first to the last 15-min periods of the match, without substantial changes in mean metabolic power (≈22 W·kg -1 ) and duration (≈6.5 s). On the contrary, mean metabolic power of the LI decreased (5.8 to 4.8 W·kg -1 ), mainly because of a longer duration thereof, thus underscoring the need for longer recovery periods between HI. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Effect of low dose, short-term creatine supplementation on muscle power output in elite youth soccer players.

    PubMed

    Yáñez-Silva, Aquiles; Buzzachera, Cosme F; Piçarro, Ivan Da C; Januario, Renata S B; Ferreira, Luis H B; McAnulty, Steven R; Utter, Alan C; Souza-Junior, Tacito P

    2017-01-01

    To determine the effects of a low dose, short-term Creatine monohydrate (Cr) supplementation (0.03 g.kg.d -1 during 14 d) on muscle power output in elite youth soccer players. Using a two-group matched, double blind, placebo-controlled design, nineteen male soccer players (mean age = 17.0 ± 0.5 years) were randomly assigned to either Cr ( N  = 9) or placebo ( N  = 10) group. Before and after supplementation, participants performed a 30s Wingate Anaerobic Test (WAnT) to assess peak power output (PPO), mean power output (MPO), fatigue index (FI), and total work. There were significant increases in both PPO and MPO after the Cr supplementation period ( P  ≤ 0.05) but not the placebo period. There were also significant increases in total work, but not FI, after the Cr supplementation and placebo periods ( P  ≤ 0.05). Notably, there were differences in total work between the Cr and placebo groups after ( P  ≤ 0.05) but not before the 14 d supplementation period. There is substantial evidence to indicate that a low-dose, short-term oral Cr supplementation beneficially affected muscle power output in elite youth soccer players.

  12. Effect of hydrothermal pre-treatment (HTP) on poultry slaughterhouse waste (PSW) sludge for the enhancement of the solubilization, physical properties, and biogas production through anaerobic digestion.

    PubMed

    Park, Seyong; Yoon, Young-Man; Han, Seong Kuk; Kim, Daegi; Kim, Ho

    2017-06-01

    This study is an assessment of the hydrothermal pre-treatment (HTP) of poultry slaughterhouse waste (PSW) sludge for the enhancement of the solubilization, physical properties, and biogas production through anaerobic digestion. This assessment was carried out to ascertain the optimal HTP temperature. The solubilization and physical properties efficacy was investigated by capillary suction time (CST), time to filter (TTF), and particle size. In addition, the anaerobic digestion was investigated through biochemical methane potential (BMP) tests and subsequent statistical analysis using the modified Gompertz model. HTP was found to have improved the solubilization of the PSW sludge with increasing HTP temperature. In addition, the results of the CST, TTF, and particle size decreased with increasing HTP temperature. These results of the assessment that was conducted in this study confirm that the HTP process indeed modifies the physical properties of PSWs to enhance the solubilization of organic solids. Nevertheless, the results of the BMP tests and the modified Gompertz model analysis show that the optimal HTP temperature of PSWs for anaerobic digestion is 190°C. These findings show that to achieve high conversion efficiency, an accurately designed pre-treatment step must be included in the overall anaerobic digestion process for wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Continuous treatment of the insensitive munitions compound N-methyl-p-nitro aniline (MNA) in an upflow anaerobic sludge blanket (UASB) bioreactor.

    PubMed

    Olivares, Christopher I; Wang, Junqin; Luna, Carlos D Silva; Field, Jim A; Abrell, Leif; Sierra-Alvarez, Reyes

    2016-02-01

    N-methyl-p-nitroaniline (MNA) is an ingredient of insensitive munitions (IM) compounds that serves as a plasticizer and helps reduce unwanted detonations. As its use becomes widespread, MNA waste streams will be generated, necessitating viable treatment options. We studied MNA biodegradation and its inhibition potential to a representative anaerobic microbial population in wastewater treatment, methanogens. Anaerobic biodegradation and toxicity assays were performed and an up-flow anaerobic sludge blanket reactor (UASB) was operated to test continuous degradation of MNA. MNA was transformed almost stoichiometrically to N-methyl-p-phenylenediamine (MPD). MPD was not mineralized; however, it was readily autoxidized and polymerized extensively upon aeration at pH = 9. In the UASB reactor, MNA was fully degraded up to a loading rate of 297.5 μM MNA d(-1). Regarding toxicity, MNA was very inhibitory to acetoclastic methanogens (IC50 = 103 μM) whereas MPD was much less toxic, causing only 13.9% inhibition at the highest concentration tested (1025 μM). The results taken as a whole indicate that anaerobic sludge can transform MNA to MPD continuously, and that the transformation decreases the cytotoxicity of the parent pollutant. MPD can be removed through extensive polymerization. These insights could help define efficient treatment options for waste streams polluted with MNA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Comparison of aerobic granulation and anaerobic membrane bioreactor technologies for winery wastewater treatment.

    PubMed

    Basset, N; López-Palau, S; Dosta, J; Mata-Álvarez, J

    2014-01-01

    An anaerobic membrane bioreactor and aerobic granulation technologies were tested at laboratory scale to treat winery wastewater, which is characterised by a high and variable biodegradable organic load. Both technologies have already been tested for alcohol fermentation wastewaters, but there is a lack of data relating to their application to winery wastewater treatment. The anaerobic membrane bioreactor, with an external microfiltration module, was started up for 230 days, achieving a biogas production of up to 0.35 L CH4L(-1)d(-1) when 1.5 kg COD m(-3)d(-1) was applied. Average flux was 10.5 L m(-2) h(-1) (LMH), obtaining a treated effluent free of suspended solids and a chemical oxygen demand (COD) concentration lower than 100 mg COD L(-1). In contrast, the aerobic granular sequencing batch reactor coped with 15 kg COD m(-3)d(-1), but effluent quality was slightly worse. Aerobic granulation was identified as a suitable technique to treat this kind of wastewater due to excellent settleability, high biomass retention and a good ability to handle high organic loads and seasonal fluctuations. However, energy generation from anaerobic digestion plays an important role, favouring anaerobic membrane bioreactor application, although it was observed to be sensitive to sudden load fluctuations, which led to a thorough pH control and alkali addition.

  15. Selection of suitable fertilizer draw solute for a novel fertilizer-drawn forward osmosis-anaerobic membrane bioreactor hybrid system.

    PubMed

    Kim, Youngjin; Chekli, Laura; Shim, Wang-Geun; Phuntsho, Sherub; Li, Sheng; Ghaffour, Noreddine; Leiknes, TorOve; Shon, Ho Kyong

    2016-06-01

    In this study, a protocol for selecting suitable fertilizer draw solute for anaerobic fertilizer-drawn forward osmosis membrane bioreactor (AnFDFOMBR) was proposed. Among eleven commercial fertilizer candidates, six fertilizers were screened further for their FO performance tests and evaluated in terms of water flux and reverse salt flux. Using selected fertilizers, bio-methane potential experiments were conducted to examine the effect of fertilizers on anaerobic activity due to reverse diffusion. Mono-ammonium phosphate (MAP) showed the highest biogas production while other fertilizers exhibited an inhibition effect on anaerobic activity with solute accumulation. Salt accumulation in the bioreactor was also simulated using mass balance simulation models. Results showed that ammonium sulfate and MAP were the most appropriate for AnFDFOMBR since they demonstrated less salt accumulation, relatively higher water flux, and higher dilution capacity of draw solution. Given toxicity of sulfate to anaerobic microorganisms, MAP appears to be the most suitable draw solution for AnFDFOMBR. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Low-temperature limitation of bioreactor sludge in anaerobic treatment of domestic wastewater.

    PubMed

    Bowen, Emma J; Dolfing, Jan; Davenport, Russell J; Read, Fiona L; Curtis, Thomas P

    2014-01-01

    Two strategies exist for seeding low-temperature anaerobic reactors: the use of specialist psychrophilic biomass or mesophilic bioreactor sludge acclimated to low temperature. We sought to determine the low-temperature limitation of anaerobic sludge from a bioreactor acclimated to UK temperatures (<15 °C). Anaerobic incubation tests using low-strength real domestic wastewater (DWW) and various alternative soluble COD sources were conducted at 4, 8 and 15 °C; methanogenesis and acidogenesis were monitored separately. Production of methane and acetate was observed; decreasing temperature resulted in decreased yields and increased 'start-up' times. At 4 °C methanogenesis not hydrolysis/acidogenesis was rate-limiting. The final methane yields at 4 °C were less than 35% of the theoretical potential whilst at 8 and 15 °C more than 75 and 100% of the theoretical yield was achieved respectively. We propose that the lower temperature limit for DWW treatment with anaerobic bioreactor sludge lies between 8 and 4 °C and that 8 °C is the threshold for reliable operation.

  17. Response of anaerobic carbon cycling to water table manipulation in an Alaskan rich fen

    Treesearch

    E.S. Kane; M.R. Chivers; M.S. Turetsky; C.C. Treat; D.G. Petersen; M. Waldrop; J.W. Harden; A.D. McGuire

    2013-01-01

    To test the effects of altered hydrology on organic soil decomposition, we investigated CO2 and CH4 production potential of rich-fen peat (mean surface pH = 6.3) collected from a field water table manipulation experiment including control, raised and lowered water table treatments. Mean anaerobic CO2...

  18. Anaerobically digested bovine biofiber as a source of fiber for particleboard manufacturing : an economic analysis

    Treesearch

    Henry Spelter; Jerrold Winandy; Timothy Zauche

    2008-01-01

    This paper explores the physical and economic potential to substitute anaerobically digested bovine biofiber (ADBF) for wood in the making of particleboard. Laboratory tests indicated that replacement of one-half the wood in particleboard with ADBF produced panels that compared favorably to the requirements for commercial particleboard performance (specified by ANSI...

  19. Active Female Maximal and Anaerobic Threshold Cardiorespiratory Responses to Six Different Water Aerobics Exercises

    ERIC Educational Resources Information Center

    Antunes, Amanda H.; Alberton, Cristine L.; Finatto, Paula; Pinto, Stephanie S.; Cadore, Eduardo L.; Zaffari, Paula; Kruel, Luiz F. M.

    2015-01-01

    Purpose: Maximal tests conducted on land are not suitable for the prescription of aquatic exercises, which makes it difficult to optimize the intensity of water aerobics classes. The aim of the present study was to evaluate the maximal and anaerobic threshold cardiorespiratory responses to 6 water aerobics exercises. Volunteers performed 3 of the…

  20. APPLICATIONS OF THE PLASTIC FILM TECHNIQUE IN THE ISOLATION AND STUDY OF ANAEROBIC BACTERIA

    PubMed Central

    Shank, J. L.

    1963-01-01

    Shank, J. L. (Swift & Co., Chicago, Ill.). Applications of the plastic film technique in the isolation and study of anaerobic bacteria. J. Bacteriol. 86:95–100. 1963.—The use of plastic films as oxygen barriers on the surface of agar pour plates, in conjunction with thioglycolate and other selective and differential agents, allows the primary isolation and enumeration of clostridia and other anaerobes. Quantitative studies reveal little if any inhibition of the test organisms under these conditions, and toxin production, where it occurs, is shown to be virtually unimpaired. Images PMID:14051828

  1. Anaerobic bacteria colonizing the lower airways in lung cancer patients.

    PubMed

    Rybojad, Pawel; Los, Renata; Sawicki, Marek; Tabarkiewicz, Jacek; Malm, Anna

    2011-01-01

    Anaerobes comprise most of the endogenous oropharyngeal microflora, and can cause infections of airways in lung cancer patients who are at high risk for respiratory tract infections. The aim of this study was to determine the frequency and species diversity of anaerobes in specimens from the lower airways of lung cancer patients. Sensitivity of the isolates to conventional antimicrobial agents used in anaerobe therapy was assessed. Respiratory secretions obtained by bronchoscopy from 30 lung cancer patients were cultured onto Wilkins-Chalgren agar in anaerobic conditions at 37°C for 72-96 hours. The isolates were identified using microtest Api 20A. The minimal inhibitory concentrations for penicillin G, amoxicillin/clavulanate, piperacillin/tazobactam, cefoxitin, imipenem, clindamycin, and metronidazole were determined by E-test. A total of 47 isolates of anaerobic bacteria were detected in 22 (73.3%) specimens. More than one species of anaerobe was found in 16 (53.3%) samples. The most frequently isolated were Actinomyces spp. and Peptostreptococcus spp., followed by Eubacterium lentum, Veillonella parvula, Prevotella spp., Bacteroides spp., Lactobacillus jensenii. Among antibiotics used in the study amoxicillin/clavulanate and imipenem were the most active in vitro (0% and 2% resistant strains, respectively). The highest resistance rate was found for penicillin G and metronidazole (36% and 38% resistant strains, respectively). The results obtained confirm the need to conduct analyses of anaerobic microflora colonizing the lower respiratory tract in patients with lung cancer to monitor potential etiologic factors of airways infections, as well as to propose efficient, empirical therapy.

  2. Leachate properties as indicators of methane production process in MSW anaerobic digestion bioreactor landfill

    NASA Astrophysics Data System (ADS)

    Zeng, Yunmin; Wang, Li'ao; Xu, Tengtun; Li, Jiaxiang; Song, Xue; Hu, Chaochao

    2018-03-01

    In this paper, bioreactor was used to simulate the municipal solid waste (MSW) biodegradation process of landfill, tracing and testing trash methanogenic process and characteristics of leachate during anaerobic digestion, exploring the relationship between the two processes, aiming to screen out the indicators that can predict the methane production process of anaerobic digestion, which provides the support for real-time adjustment of technological parameters of MSW anaerobic digestion system and ensures the efficient operation of bioreactor landfill. The results showed that MSW digestion gas production rate constant is 0.0259 1/d, biogas production potential is 61.93 L/kg. The concentration of TN in leachate continued to increase, showing the trend of nitrogen accumulation. "Ammonia poisoning" was an important factor inhibiting waste anaerobic digestion gas production. In the anaerobic digestion system, although pH values of leachate can indicate methane production process to some degree, there are obvious lagging behind, so it cannot be used as indicator alone. The TOC/TN value of leachate has a certain indication on the stability of the methane production system. When TOC/TN value was larger than12, anaerobic digestion system was stable along with normal production of biogas. However, when TOC/TN value was lower than 12, the digestive system is unstable and the gas production is small. In the process of anaerobic digestion, the synthesis and transformation of valeric acid is more active. HAc/HVa changed greatly and had obvious inflection points, from which methane production period can be predicted.

  3. Relationship between Nutrition Knowledge and Physical Fitness in Semiprofessional Soccer Players

    PubMed Central

    Nikolaidis, P. T.; Theodoropoulou, E.

    2014-01-01

    Whereas nutrition has a crucial role on sport performance, it is not clear to what extent nutrition knowledge is associated with physical fitness. The aim of this study was to examine the current level of nutrition knowledge of soccer players and whether this level is associated with physical fitness. Soccer players (n = 185, aged 21.3 ± 4.9 yr, weight 72.3 ± 8.4 kg, and height 177.5 ± 6.4 cm) performed a battery of physical fitness tests (sit-and-reach test, SAR; physical working capacity in heart rate 170, PWC170; and Wingate anaerobic test, WAnT) and completed an 11-item nutrition knowledge questionnaire (NKQ). Low to moderate Pearson correlations (0.15 < r < 0.34, p < 0.05) of NKQ with age, weight, height, fat free mass (FFM), SAR, peak power, and mean power of WAnT were observed. Soccer players with high score in NKQ were older (4.4 yr (2.2; 6.6), mean difference (95% confidence intervals)) and heavier (4.5 kg (0.6; 8.3)) with higher FFM (4.0 kg (1.1; 6.8)) and peak power (59 W (2; 116)) than their counterparts with low score. The moderate score in the NKQ suggests that soccer players should be targeted for nutrition education. Although the association between NKQ and physical fitness was low to moderate, there were indications that better nutrition knowledge might result in higher physical fitness and, consequently, soccer performance. PMID:25140277

  4. Relationship between Nutrition Knowledge and Physical Fitness in Semiprofessional Soccer Players.

    PubMed

    Nikolaidis, P T; Theodoropoulou, E

    2014-01-01

    Whereas nutrition has a crucial role on sport performance, it is not clear to what extent nutrition knowledge is associated with physical fitness. The aim of this study was to examine the current level of nutrition knowledge of soccer players and whether this level is associated with physical fitness. Soccer players (n = 185, aged 21.3 ± 4.9 yr, weight 72.3 ± 8.4 kg, and height 177.5 ± 6.4 cm) performed a battery of physical fitness tests (sit-and-reach test, SAR; physical working capacity in heart rate 170, PWC170; and Wingate anaerobic test, WAnT) and completed an 11-item nutrition knowledge questionnaire (NKQ). Low to moderate Pearson correlations (0.15 < r < 0.34, p < 0.05) of NKQ with age, weight, height, fat free mass (FFM), SAR, peak power, and mean power of WAnT were observed. Soccer players with high score in NKQ were older (4.4 yr (2.2; 6.6), mean difference (95% confidence intervals)) and heavier (4.5 kg (0.6; 8.3)) with higher FFM (4.0 kg (1.1; 6.8)) and peak power (59 W (2; 116)) than their counterparts with low score. The moderate score in the NKQ suggests that soccer players should be targeted for nutrition education. Although the association between NKQ and physical fitness was low to moderate, there were indications that better nutrition knowledge might result in higher physical fitness and, consequently, soccer performance.

  5. Anaerobic digestion of amine-oxide-based surfactants: biodegradation kinetics and inhibitory effects.

    PubMed

    Ríos, Francisco; Lechuga, Manuela; Fernández-Arteaga, Alejandro; Jurado, Encarnación; Fernández-Serrano, Mercedes

    2017-08-01

    Recently, anaerobic degradation has become a prevalent alternative for the treatment of wastewater and activated sludge. Consequently, the anaerobic biodegradability of recalcitrant compounds such as some surfactants require a thorough study to avoid their presence in the environment. In this work, the anaerobic biodegradation of amine-oxide-based surfactants, which are toxic to several organisms, was studied by measuring of the biogas production in digested sludge. Three amine-oxide-based surfactants with structural differences in their hydrophobic alkyl chain were tested: Lauramine oxide (AO-R 12 ), Myristamine oxide (AO-R 14 ) and Cocamidopropylamine oxide (AO-cocoamido). Results show that AO-R 12 and AO-R 14 inhibit biogas production, inhibition percentages were around 90%. AO-cocoamido did not cause inhibition and it was biodegraded until reaching a percentage of 60.8%. Otherwise, we fitted the production of biogas to two kinetic models, to a pseudo first-order model and to a logistic model. Production of biogas during the anaerobic biodegradation of AO-cocoamido was pretty good adjusted to the logistics model. Kinetic parameters were also determined. This modelling is useful to predict their behaviour in wastewater treatment plants and under anaerobic conditions in the environment.

  6. The Effect of a 12-Week Beta-hydroxy-beta-methylbutyrate (HMB) Supplementation on Highly-Trained Combat Sports Athletes: A Randomised, Double-Blind, Placebo-Controlled Crossover Study

    PubMed Central

    Jeszka, Jan; Podgórski, Tomasz

    2017-01-01

    The aim of this study was to verify the effect of beta-hydroxy-beta-methylbutyrate (HMB) supplementation on physical capacity, body composition and the value of biochemical parameters in highly-trained combat sports athletes. Forty-two males highly-trained in combat sports were subjected to 12 weeks of supplementation with HMB and a placebo in a randomized, placebo controlled, double-blind crossover manner. Over the course of the experiment, aerobic and anaerobic capacity was determined, while analyses were conducted on body composition and levels of creatine kinase, lactate dehydrogenase, testosterone, cortisol and lactate. Following HMB supplementation, fat-free mass increased (p = 0.049) with a simultaneous reduction of fat mass (p = 0.016) in comparison to placebo. In turn, after HMB supplementation, the following indicators increased significantly in comparison to the placebo: the time to reach ventilatory threshold (p < 0.0001), threshold load (p = 0.017) and the threshold HR (p < 0.0001), as well as anaerobic peak power (p = 0.005), average power (p = 0.029), maximum speed (p < 0.001) and post-exercise lactate concentrations (p < 0.0001). However, when compared to the placebo, no differences were observed in blood marker levels. The results indicate that supplying HMB promotes advantageous changes in body composition and stimulates an increase in aerobic and anaerobic capacity in combat sports athletes. PMID:28708126

  7. The Effect of a 12-Week Beta-hydroxy-beta-methylbutyrate (HMB) Supplementation on Highly-Trained Combat Sports Athletes: A Randomised, Double-Blind, Placebo-Controlled Crossover Study.

    PubMed

    Durkalec-Michalski, Krzysztof; Jeszka, Jan; Podgórski, Tomasz

    2017-07-14

    The aim of this study was to verify the effect of beta-hydroxy-beta-methylbutyrate (HMB) supplementation on physical capacity, body composition and the value of biochemical parameters in highly-trained combat sports athletes. Forty-two males highly-trained in combat sports were subjected to 12 weeks of supplementation with HMB and a placebo in a randomized, placebo controlled, double-blind crossover manner. Over the course of the experiment, aerobic and anaerobic capacity was determined, while analyses were conducted on body composition and levels of creatine kinase, lactate dehydrogenase, testosterone, cortisol and lactate. Following HMB supplementation, fat-free mass increased ( p = 0.049) with a simultaneous reduction of fat mass ( p = 0.016) in comparison to placebo. In turn, after HMB supplementation, the following indicators increased significantly in comparison to the placebo: the time to reach ventilatory threshold ( p < 0.0001), threshold load ( p = 0.017) and the threshold HR ( p < 0.0001), as well as anaerobic peak power ( p = 0.005), average power ( p = 0.029), maximum speed ( p < 0.001) and post-exercise lactate concentrations ( p < 0.0001). However, when compared to the placebo, no differences were observed in blood marker levels. The results indicate that supplying HMB promotes advantageous changes in body composition and stimulates an increase in aerobic and anaerobic capacity in combat sports athletes.

  8. Metagenomic Evidence for H2 Oxidation and H2 Production by Serpentinite-Hosted Subsurface Microbial Communities

    PubMed Central

    Brazelton, William J.; Nelson, Bridget; Schrenk, Matthew O.

    2012-01-01

    Ultramafic rocks in the Earth’s mantle represent a tremendous reservoir of carbon and reducing power. Upon tectonic uplift and exposure to fluid flow, serpentinization of these materials generates copious energy, sustains abiogenic synthesis of organic molecules, and releases hydrogen gas (H2). In order to assess the potential for microbial H2 utilization fueled by serpentinization, we conducted metagenomic surveys of a marine serpentinite-hosted hydrothermal chimney (at the Lost City hydrothermal field) and two continental serpentinite-hosted alkaline seeps (at the Tablelands Ophiolite, Newfoundland). Novel [NiFe]-hydrogenase sequences were identified at both the marine and continental sites, and in both cases, phylogenetic analyses indicated aerobic, potentially autotrophic Betaproteobacteria belonging to order Burkholderiales as the most likely H2-oxidizers. Both sites also yielded metagenomic evidence for microbial H2 production catalyzed by [FeFe]-hydrogenases in anaerobic Gram-positive bacteria belonging to order Clostridiales. In addition, we present metagenomic evidence at both sites for aerobic carbon monoxide utilization and anaerobic carbon fixation via the Wood–Ljungdahl pathway. In general, our results point to H2-oxidizing Betaproteobacteria thriving in shallow, oxic–anoxic transition zones and the anaerobic Clostridia thriving in anoxic, deep subsurface habitats. These data demonstrate the feasibility of metagenomic investigations into novel subsurface habitats via surface-exposed seeps and indicate the potential for H2-powered primary production in serpentinite-hosted subsurface habitats. PMID:22232619

  9. Metagenomic evidence for h(2) oxidation and h(2) production by serpentinite-hosted subsurface microbial communities.

    PubMed

    Brazelton, William J; Nelson, Bridget; Schrenk, Matthew O

    2012-01-01

    Ultramafic rocks in the Earth's mantle represent a tremendous reservoir of carbon and reducing power. Upon tectonic uplift and exposure to fluid flow, serpentinization of these materials generates copious energy, sustains abiogenic synthesis of organic molecules, and releases hydrogen gas (H(2)). In order to assess the potential for microbial H(2) utilization fueled by serpentinization, we conducted metagenomic surveys of a marine serpentinite-hosted hydrothermal chimney (at the Lost City hydrothermal field) and two continental serpentinite-hosted alkaline seeps (at the Tablelands Ophiolite, Newfoundland). Novel [NiFe]-hydrogenase sequences were identified at both the marine and continental sites, and in both cases, phylogenetic analyses indicated aerobic, potentially autotrophic Betaproteobacteria belonging to order Burkholderiales as the most likely H(2)-oxidizers. Both sites also yielded metagenomic evidence for microbial H(2) production catalyzed by [FeFe]-hydrogenases in anaerobic Gram-positive bacteria belonging to order Clostridiales. In addition, we present metagenomic evidence at both sites for aerobic carbon monoxide utilization and anaerobic carbon fixation via the Wood-Ljungdahl pathway. In general, our results point to H(2)-oxidizing Betaproteobacteria thriving in shallow, oxic-anoxic transition zones and the anaerobic Clostridia thriving in anoxic, deep subsurface habitats. These data demonstrate the feasibility of metagenomic investigations into novel subsurface habitats via surface-exposed seeps and indicate the potential for H(2)-powered primary production in serpentinite-hosted subsurface habitats.

  10. Ecotoxicological assessment of grey water treatment systems with Daphnia magna and Chironomus riparius.

    PubMed

    Hernández Leal, L; Soeter, A M; Kools, S A E; Kraak, M H S; Parsons, J R; Temmink, H; Zeeman, G; Buisman, C J N

    2012-03-15

    In order to meet environmental quality criteria, grey water was treated in four different ways: 1) aerobic 2) anaerobic+aerobic 3) aerobic+activated carbon 4) aerobic+ozone. Since each treatment has its own specific advantages and disadvantages, the aim of this study was to compare the ecotoxicity of differently treated grey water using Chironomus riparius (96 h test) and Daphnia magna (48 h and 21d test) as test organisms. Grey water exhibited acute toxicity to both test organisms. The aerobic and combined anaerobic+aerobic treatment eliminated mortality in the acute tests, but growth of C. riparius was still affected by these two effluents. Post-treatment by ozone and activated carbon completely removed the acute toxicity from grey water. In the chronic toxicity test the combined anaerobic+aerobic treatment strongly affected D. magna population growth rate (47%), while the aerobic treatment had a small (9%) but significant effect. Hence, aerobic treatment is the best option for biological treatment of grey water, removing most of the toxic effects of grey water. If advanced treatment is required, the treatment with either ozone or GAC were shown to be very effective in complete removal of toxicity from grey water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. In Vitro Activities of ABT-492, a New Fluoroquinolone, against 155 Aerobic and 171 Anaerobic Pathogens Isolated from Antral Sinus Puncture Specimens from Patients with Sinusitis

    PubMed Central

    Goldstein, Ellie J. C.; Citron, Diane M.; Merriam, C. Vreni; Warren, Yumi A.; Tyrrell, Kerin L.; Fernandez, Helen T.

    2003-01-01

    ABT-492 exhibited excellent in vitro activities against all 326 aerobic and anaerobic antral puncture sinus isolates tested with MICs (in micrograms per milliliter) at which 90% of the isolates tested were inhibited as follows: Haemophilus influenzae, 0.001; Moraxella catarrhalis, 0.008; and Streptococcus pneumoniae, 0.015. It was four- to sixfold more active than other fluoroquinolones, including against levofloxacin-resistant strains of S. pneumoniae, methicillin-resistant Staphylococcus aureus, and Prevotella species. PMID:12937015

  12. In vitro activities of ABT-492, a new fluoroquinolone, against 155 aerobic and 171 anaerobic pathogens isolated from antral sinus puncture specimens from patients with sinusitis.

    PubMed

    Goldstein, Ellie J C; Citron, Diane M; Merriam, C Vreni; Warren, Yumi A; Tyrrell, Kerin L; Fernandez, Helen T

    2003-09-01

    ABT-492 exhibited excellent in vitro activities against all 326 aerobic and anaerobic antral puncture sinus isolates tested with MICs (in micrograms per milliliter) at which 90% of the isolates tested were inhibited as follows: Haemophilus influenzae, 0.001; Moraxella catarrhalis, 0.008; and Streptococcus pneumoniae, 0.015. It was four- to sixfold more active than other fluoroquinolones, including against levofloxacin-resistant strains of S. pneumoniae, methicillin-resistant Staphylococcus aureus, and Prevotella species.

  13. Ability to work in anaerobic condition is associated with physical performance on the six-minute walk test in older patients receiving cardiac rehabilitation.

    PubMed

    Pasquini, Guido; Vannetti, Federica; Molino-Lova, Raffaele

    2015-05-01

    During maximal incremental exercise, the ability to work in the anaerobic condition, expressed by the respiratory exchange ratio, is associated with physical performance. Further, peak respiratory exchange ratio is regarded as the best non-invasive measure of a patient's actual exercise effort. This study examined whether ability to work in the anaerobic condition is also associated with physical performance in submaximal constant work rate exercise. A total of 75 older patients (51 men, 24 women), mean age 71.1 years (standard deviation 6.7 years), who had recently undergone cardiac surgery, performed cardiopulmonary exercise testing in a 6-min walk test before and after rehabilitation. The distance walked, steady-state oxygen uptake, carbon dioxide output and respiratory exchange ratio increased significantly after rehabilitation (p < 0.001 for all). In multivariable models predicting the distance walked before and after rehabilitation, higher steady-state respiratory exchange ratio was independently associated with longer distance (p < 0.001 for both). In older patients receiving post-acute cardiac rehabilitation the ability to work in the anaerobic condition is associated with physical performance in submaximal constant work rate exercises. Thus the steady-state respiratory exchange ratio might be regarded as a measure of the patient's actual exercise effort. This information may prove useful in customizing exercise prescription and assessing the effects of rehabilitation.

  14. Kinetics and methane gas yields of selected C1 to C5 organic acids in anaerobic digestion.

    PubMed

    Yang, Yu; Chen, Qian; Guo, Jialiang; Hu, Zhiqiang

    2015-12-15

    Volatile fatty acids (VFAs) and other short-chain organic acids such as lactic and pyruvic acids are intermediates in anaerobic organic degradation. In this study, anaerobic degradation of seven organic acids in salt form was investigated, including formate (C1), acetate (C2), propionate (C3), pyruvate (C3), lactate (C3), butyrate (C4), and valerate (C5). Microbial growth kinetics on these organic acids were determined individually at 37 °C through batch anaerobic digestion tests by varying substrate concentrations from 250 to 4000 mg COD/L. The cumulative methane generation volume was determined real-time by respirometry coupled with gas chromatographic analysis while methane yield and related kinetics were calculated. The methane gas yields (fe, mg CH4 COD/mg substrate COD) from anaerobic degradation of formate, acetate, propionate, pyruvate, lactate, butyrate, and valerate were 0.44 ± 0.27, 0.58 ± 0.05, 0.53 ± 0.18, 0.24 ± 0.05, 0.17 ± 0.05, 0.43 ± 0.15, 0.49 ± 0.11, respectively. Anaerobic degradation of formate showed self-substrate inhibition at the concentrations above 3250 mg COD/L. Acetate, propionate, pyruvate, butyrate, lactate, and valerate did not inhibit methane production at the highest concentrations tested (i.e., 4000 mg COD/L). Microbes growing on acetate had the highest overall specific growth rate (0.30 d(-1)) in methane production. For comparison, the specific microbial growth rates on formate, propionate, pyruvate, butyrate, lactate, and valerate for methane production were 0.10, 0.06, 0.08, 0.07, 0.05, 0.15 d(-1), respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. ANAEROBIC SOIL DISINFESTATION IN MICROCOSMS OF TWO SANDY SOILS.

    PubMed

    Stremińska, M A; Runia, W T; Termorshuizen, A J; Feil, H; Van Der Wurff, A W G

    2014-01-01

    In recent years, anaerobic soil disinfestation (ASD) has been proposed as an alternative control method of soil-borne plant pathogens. It involves adding a labile carbon source, irrigating the soil to stimulate decomposition of organic material and then covering the soil with air-tight plastic to limit gas exchange. During the ASD process, soil microorganisms switch from aerobic to anaerobic metabolism. As a result, by-products of anaerobic metabolism are released into the soil environment such as various organic acids and gases. These by-products are reported to have a negative effect on survival of soil-borne plant pathogens. However, the efficacy of ASD to reduce soil-borne pathogens in practice may vary significantly. Therefore, we studied the efficacy of the ASD process in two different soils. In addition, it was investigated whether a pre-treatment with an anaerobic bacterial inoculum prior to ASD affected the efficacy of the process. Two sandy soils (dune sand and glacial sand) were inoculated in 2 L soil microcosms. We tested the efficacy of ASD treatment against the potato cyst nematode Globodera pallida. For each soil, three treatments were used: control treatment (no Herbie addition, aerobic incubation), ASD 1 (organic substrate addition, anaerobic incubation) and ASD 2 (organic substrate and anaerobic bacterial inoculum addition, anaerobic incubation). Soil microcosms were incubated in the dark at 20°C for two weeks. We observed that anaerobic soil disinfestation treatments were highly effective against Potato Cyst Nematode (PCN), with pathogen being eradicated totally in all but one ASD treatment (glacial sand ASD2) within two weeks. The relative abundance of Firmicutes (spore-forming bacteria, often fermentative) in total bacteria increased significantly in ASD treated soils. Numbers of these bacteria correlated positively with increased concentrations of acetic and butyric acids in soil water phase in ASD treatments.

  16. EVALUATION OF THE TEA TREE OIL ACTIVITY TO ANAEROBIC BACTERIA--IN VITRO STUDY.

    PubMed

    Ziółkowska-Klinkosz, Marta; Kedzia, Anna; Meissner, Hhenry O; Kedzia, Andrzej W

    2016-01-01

    The study of the sensitivity to tea tree oil (Australian Company TTD International Pty. Ltd. Sydney) was carried out on 193 strains of anaerobic bacteria isolated from patients with various infections within the oral cavity and respiratory tracts. The susceptibility (MIC) of anaerobes was determined by means of plate dilution technique in Brucella agar supplemented with 5% defibrinated sheep blood, menadione and hemin. Inoculum contained 10(5) CFU per spot was cultured with Steers replicator upon the surface of agar with various tea tree oil concentrations or without oil (anaerobes growth control). Incubation the plates was performed in anaerobic jars under anaerobic conditions at 37 degrees C for 48 h. MIC was defined as the lowest concentrations of the essential oil completely inhibiting growth of anaerobic bacteria. Test results indicate, that among Gram-negative bacteria the most sensitive to essential oil were strains of Veillonella and Porphyromonas species. Essential oil in low concentrations (MIC in the range of = 0.12 - 0.5 mg/mL) inhibited growth of accordingly 80% and 68% strains. The least sensitive were strains of the genus Tannerella, Parabacteroides and Dialister (MIC 1.0 - 2.0 mg/mL). In the case of Gram-positive anaerobic bacteria the tea tree oil was the most active to strains of cocci of the genus Anaerococcus and Ruminococcus (MIC in range = 0.12 - 0.5 mg/mL) or strains of rods of the genus Eubacterium and Eggerthella (MIC = 0.25 mg/mL). Among Gram-positive rods the least sensitive were the strains of the genus Bifidobacterium ( MIC = 2.0 mg/mL). The tea tree oil was more active to Gram-positive than to Gram-negative anaerobic bacteria.

  17. Site-Specific Management of Miscanthus Genotypes for Combustion and Anaerobic Digestion: A Comparison of Energy Yields.

    PubMed

    Kiesel, Andreas; Nunn, Christopher; Iqbal, Yasir; Van der Weijde, Tim; Wagner, Moritz; Özgüven, Mensure; Tarakanov, Ivan; Kalinina, Olena; Trindade, Luisa M; Clifton-Brown, John; Lewandowski, Iris

    2017-01-01

    In Europe, the perennial C 4 grass miscanthus is currently mainly cultivated for energy generation via combustion. In recent years, anaerobic digestion has been identified as a promising alternative utilization pathway. Anaerobic digestion produces a higher-value intermediate (biogas), which can be upgraded to biomethane, stored in the existing natural gas infrastructure and further utilized as a transport fuel or in combined heat and power plants. However, the upgrading of the solid biomass into gaseous fuel leads to conversion-related energy losses, the level of which depends on the cultivation parameters genotype, location, and harvest date. Thus, site-specific crop management needs to be adapted to the intended utilization pathway. The objectives of this paper are to quantify (i) the impact of genotype, location and harvest date on energy yields of anaerobic digestion and combustion and (ii) the conversion losses of upgrading solid biomass into biogas. For this purpose, five miscanthus genotypes (OPM 3, 6, 9, 11, 14), three cultivation locations (Adana, Moscow, Stuttgart), and up to six harvest dates (August-March) were assessed. Anaerobic digestion yielded, on average, 35% less energy than combustion. Genotype, location, and harvest date all had significant impacts on the energy yield. For both, this is determined by dry matter yield and ash content and additionally by substrate-specific methane yield for anaerobic digestion and moisture content for combustion. Averaged over all locations and genotypes, an early harvest in August led to 25% and a late harvest to 45% conversion losses. However, each utilization option has its own optimal harvest date, determined by biomass yield, biomass quality, and cutting tolerance. By applying an autumn green harvest for anaerobic digestion and a delayed harvest for combustion, the conversion-related energy loss was reduced to an average of 18%. This clearly shows that the delayed harvest required to maintain biomass quality for combustion is accompanied by high energy losses through yield reduction over winter. The pre-winter harvest applied in the biogas utilization pathway avoids these yield losses and largely compensates for the conversion-related energy losses of anaerobic digestion.

  18. Site-Specific Management of Miscanthus Genotypes for Combustion and Anaerobic Digestion: A Comparison of Energy Yields

    PubMed Central

    Kiesel, Andreas; Nunn, Christopher; Iqbal, Yasir; Van der Weijde, Tim; Wagner, Moritz; Özgüven, Mensure; Tarakanov, Ivan; Kalinina, Olena; Trindade, Luisa M.; Clifton-Brown, John; Lewandowski, Iris

    2017-01-01

    In Europe, the perennial C4 grass miscanthus is currently mainly cultivated for energy generation via combustion. In recent years, anaerobic digestion has been identified as a promising alternative utilization pathway. Anaerobic digestion produces a higher-value intermediate (biogas), which can be upgraded to biomethane, stored in the existing natural gas infrastructure and further utilized as a transport fuel or in combined heat and power plants. However, the upgrading of the solid biomass into gaseous fuel leads to conversion-related energy losses, the level of which depends on the cultivation parameters genotype, location, and harvest date. Thus, site-specific crop management needs to be adapted to the intended utilization pathway. The objectives of this paper are to quantify (i) the impact of genotype, location and harvest date on energy yields of anaerobic digestion and combustion and (ii) the conversion losses of upgrading solid biomass into biogas. For this purpose, five miscanthus genotypes (OPM 3, 6, 9, 11, 14), three cultivation locations (Adana, Moscow, Stuttgart), and up to six harvest dates (August–March) were assessed. Anaerobic digestion yielded, on average, 35% less energy than combustion. Genotype, location, and harvest date all had significant impacts on the energy yield. For both, this is determined by dry matter yield and ash content and additionally by substrate-specific methane yield for anaerobic digestion and moisture content for combustion. Averaged over all locations and genotypes, an early harvest in August led to 25% and a late harvest to 45% conversion losses. However, each utilization option has its own optimal harvest date, determined by biomass yield, biomass quality, and cutting tolerance. By applying an autumn green harvest for anaerobic digestion and a delayed harvest for combustion, the conversion-related energy loss was reduced to an average of 18%. This clearly shows that the delayed harvest required to maintain biomass quality for combustion is accompanied by high energy losses through yield reduction over winter. The pre-winter harvest applied in the biogas utilization pathway avoids these yield losses and largely compensates for the conversion-related energy losses of anaerobic digestion. PMID:28367151

  19. A fuzzy logic approach to control anaerobic digestion.

    PubMed

    Domnanovich, A M; Strik, D P; Zani, L; Pfeiffer, B; Karlovits, M; Braun, R; Holubar, P

    2003-01-01

    One of the goals of the EU-Project AMONCO (Advanced Prediction, Monitoring and Controlling of Anaerobic Digestion Process Behaviour towards Biogas Usage in Fuel Cells) is to create a control tool for the anaerobic digestion process, which predicts the volumetric organic loading rate (Bv) for the next day, to obtain a high biogas quality and production. The biogas should contain a high methane concentration (over 50%) and a low concentration of components toxic for fuel cells, e.g. hydrogen sulphide, siloxanes, ammonia and mercaptanes. For producing data to test the control tool, four 20 l anaerobic Continuously Stirred Tank Reactors (CSTR) are operated. For controlling two systems were investigated: a pure fuzzy logic system and a hybrid-system which contains a fuzzy based reactor condition calculation and a hierachial neural net in a cascade of optimisation algorithms.

  20. Case Study: Unfavorable But Transient Physiological Changes During Contest Preparation in a Drug-Free Male Bodybuilder.

    PubMed

    Pardue, Andrew; Trexler, Eric T; Sprod, Lisa K

    2017-12-01

    Extreme body composition demands of competitive bodybuilding have been associated with unfavorable physiological changes, including alterations in metabolic rate and endocrine profile. The current case study evaluated the effects of contest preparation (8 months), followed by recovery (5 months), on a competitive drug-free male bodybuilder over 13 months (M1-M13). Serum testosterone, triiodothyronine (T 3 ), thyroxine (T 4 ), cortisol, leptin, and ghrelin were measured throughout the study. Body composition (BodPod, dualenergy x-ray absorptiometry [DXA]), anaerobic power (Wingate test), and resting metabolic rate (RMR) were assessed monthly. Sleep was assessed monthly via the Pittsburgh Sleep Quality Index (PSQI) and actigraphy. From M1 to M8, testosterone (623-173 ng∙dL -1 ), T 3 (123-40 ng∙dL -1 ), and T 4 (5.8-4.1 mg∙dL -1 ) decreased, while cortisol (25.2-26.5 mg∙dL -1 ) and ghrelin (383-822 pg∙mL -1 ) increased. The participant lost 9.1 kg before competition as typical energy intake dropped from 3,860 to 1,724 kcal∙day -1 ; BodPod estimates of body fat percentage were 13.4% at M1, 9.6% at M8, and 14.9% at M13; DXA estimates were 13.8%, 5.1%, and 13.8%, respectively. Peak anaerobic power (753.0 to 536.5 Watts) and RMR (107.2% of predicted to 81.2% of predicted) also decreased throughout preparation. Subjective sleep quality decreased from M1 to M8, but objective measures indicated minimal change. By M13, physiological changes were largely, but not entirely, reversed. Contest preparation may yield transient, unfavorable changes in endocrine profile, power output, RMR, and subjective sleep outcomes. Research with larger samples must identify strategies that minimize unfavorable adaptations and facilitate recovery following competition.

  1. Sequential anaerobic/aerobic digestion of waste activated sludge: analysis of the process performance and kinetic study.

    PubMed

    Tomei, M Concetta; Rita, Sara; Mininni, Giuseppe

    2011-12-15

    Sequential anaerobic-aerobic digestion was applied to waste activated sludge (WAS) of a full scale wastewater treatment plant. The study was performed with the objective of testing the sequential digestion process on WAS, which is characterized by worse digestibility in comparison with the mixed sludge. Process performance was evaluated in terms of biogas production, volatile solids (VS) and COD reduction, and patterns of biopolymers (proteins and polysaccharides) in the subsequent digestion stages. VS removal efficiency of 40%, in the anaerobic phase, and an additional removal of 26%, in the aerobic one, were observed. For total COD removal efficiencies of 35% and 25% for anaerobic and aerobic stage respectively, were obtained. Kinetics of VS degradation process was analyzed by assuming a first order equation with respect to VS concentration. Evaluated kinetic parameters were 0.44 ± 0.20 d(-1) and 0.25 ± 0.15 d(-1) for the anaerobic stage and aerobic stage, respectively. With regard to biopolymers, in the anaerobic phase the content of proteins and polysaccharides increased to 50% and 69%, respectively, whereas in the subsequent aerobic phase, a decrease of 71% for proteins and 67% for polysaccharides was observed. The average specific biogas production 0.74 m(3)/(kg VS destroyed), was in the range of values reported in the specialized literature for conventional anaerobic mesophilic WAS digestion. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Anaerobic electron acceptor chemotaxis in Shewanella putrefaciens

    NASA Technical Reports Server (NTRS)

    Nealson, K. H.; Moser, D. P.; Saffarini, D. A.

    1995-01-01

    Shewanella putrefaciens MR-1 can grow either aerobically or anaerobically at the expense of many different electron acceptors and is often found in abundance at redox interfaces in nature. Such redox interfaces are often characterized by very strong gradients of electron acceptors resulting from rapid microbial metabolism. The coincidence of S. putrefaciens abundance with environmental gradients prompted an examination of the ability of MR-1 to sense and respond to electron acceptor gradients in the laboratory. In these experiments, taxis to the majority of the electron acceptors that S. putrefaciens utilizes for anaerobic growth was seen. All anaerobic electron acceptor taxis was eliminated by the presence of oxygen, nitrate, nitrite, elemental sulfur, or dimethyl sulfoxide, even though taxis to the latter was very weak and nitrate and nitrite respiration was normal in the presence of dimethyl sulfoxide. Studies with respiratory mutants of MR-1 revealed that several electron acceptors that could not be used for anaerobic growth nevertheless elicited normal anaerobic taxis. Mutant M56, which was unable to respire nitrite, showed normal taxis to nitrite, as well as the inhibition of taxis to other electron acceptors by nitrite. These results indicate that electron acceptor taxis in S. putrefaciens does not conform to the paradigm established for Escherichia coli and several other bacteria. Carbon chemo-taxis was also unusual in this organism: of all carbon compounds tested, the only positive response observed was to formate under anaerobic conditions.

  3. Vaginal lactobacilli inhibiting growth of Gardnerella vaginalis, Mobiluncus and other bacterial species cultured from vaginal content of women with bacterial vaginosis.

    PubMed

    Skarin, A; Sylwan, J

    1986-12-01

    On a solid agar medium the growth-inhibitory effect of 9 Lactobacillus strains cultured from vaginal content was tested on bacteria cultured from vaginal content of women with bacterial vaginosis: Mobiluncus, Gardnerella vaginalis, Bacteroides and anaerobic cocci. Inhibition zones were observed in the growth of all of the strains isolated from women with bacterial vaginosis around all lactobacilli. The inhibitory effect of the lactobacilli was further tested on various anaerobic and facultatively anaerobic species, both type strains and fresh extragenitally cultured strains. Four Bacteroides fragilis strains as well as 2 out of 4 Staphylococcus aureus strains were clearly inhibited by the lactobacilli. The inhibition zones were generally wider at pH 5.5 than at 6.0. For all inhibited strains, (the S. aureus excepted) a low pH on the agar around the lactobacilli correlated to wider growth-inhibition zones.

  4. Anaerobic biodegradation of BTEX using Mn(IV) and Fe(III) as alternative electron acceptors.

    PubMed

    Villatoro-Monzón, W R; Mesta-Howard, A M; Razo-Flores, E

    2003-01-01

    Anaerobic BTEX biodegradation was tested in batch experiments using an anaerobic sediment as inoculum under Fe(III) and Mn(IV) reducing conditions. All BTEX were degraded under the conditions tested, specially under Mn(IV) reducing conditions, where benzene was degraded at a rate of 0.8 micromol l(-1) d(-1), significantly much faster than Fe(III) reducing conditions. Under Fe(III) reducing conditions, ethylbenzene was the compound that degraded at the faster rate of 0.19 micromol l(-1) d(-1). Mn(IV) reducing conditions are energetically more favourable than Fe(III), therefore, BTEX were more rapidly degraded under Mn(IV) reducing conditions. These results represent the first report of the degradation of benzene with Mn(IV) as the final electron acceptor. Amorphous manganese oxide is a natural widely distributed metal in groundwater, where it can be microbiologically reduced, leading to the degradation of monoaromatic compounds.

  5. The influence of somatotype on anaerobic performance

    PubMed Central

    Faulkner, James; Jobson, Simon

    2018-01-01

    The link between athlete physique and performance in sports is well established. However, a direct link between somatotype three-numeral rating and anaerobic performance has not yet been reported. The purpose of this study was to assess the relations between somatotype and anaerobic performance using both singular and multivariate analyses. Thirty-six physically active males (mean ± standard deviation age 26.0 ± 9.8 years; body mass 79.5 ± 12.9 kg; height 1.82 ± 0.07 m) were somatotype-rated using the Heath-Carter method. Subjects were assessed for 3 repetition maximum (3 RM) bench press and back squat, and completed a 30-second maximal sprint cycle test. Positive correlations were observed between mesomorphy and 3 RM bench press (r = 0.560, p < 0.001), mesomorphy and 3 RM back squat (r = 0.550, p = 0.001) and between mesomorphy and minimum power output (r = 0.357, p = 0.033). Negative correlations were observed between ectomorphy and 3 RM bench press (r = -0.381, p = 0.022), and ectomorphy and 3 RM back squat (r = -0.336, p = 0.045). Individual regression analysis indicated that mesomorphy was the best predictor of 3 RM bench press performance, with 31.4% of variance in 3 RM bench press performance accounted for by the mesomorphy rating (p < 0.001). A combination of mesomorphy and ectomorphy best predicted 3 RM back squat performance (R2 = 0.388, p < 0.04). Around one third of strength performance is predicted by somatotype-assessed physique in physically active males. This could have important implications for the identification of those predisposed to perform well in sports containing strength-based movements and prescription of training programmes. PMID:29787610

  6. The influence of somatotype on anaerobic performance.

    PubMed

    Ryan-Stewart, Helen; Faulkner, James; Jobson, Simon

    2018-01-01

    The link between athlete physique and performance in sports is well established. However, a direct link between somatotype three-numeral rating and anaerobic performance has not yet been reported. The purpose of this study was to assess the relations between somatotype and anaerobic performance using both singular and multivariate analyses. Thirty-six physically active males (mean ± standard deviation age 26.0 ± 9.8 years; body mass 79.5 ± 12.9 kg; height 1.82 ± 0.07 m) were somatotype-rated using the Heath-Carter method. Subjects were assessed for 3 repetition maximum (3 RM) bench press and back squat, and completed a 30-second maximal sprint cycle test. Positive correlations were observed between mesomorphy and 3 RM bench press (r = 0.560, p < 0.001), mesomorphy and 3 RM back squat (r = 0.550, p = 0.001) and between mesomorphy and minimum power output (r = 0.357, p = 0.033). Negative correlations were observed between ectomorphy and 3 RM bench press (r = -0.381, p = 0.022), and ectomorphy and 3 RM back squat (r = -0.336, p = 0.045). Individual regression analysis indicated that mesomorphy was the best predictor of 3 RM bench press performance, with 31.4% of variance in 3 RM bench press performance accounted for by the mesomorphy rating (p < 0.001). A combination of mesomorphy and ectomorphy best predicted 3 RM back squat performance (R2 = 0.388, p < 0.04). Around one third of strength performance is predicted by somatotype-assessed physique in physically active males. This could have important implications for the identification of those predisposed to perform well in sports containing strength-based movements and prescription of training programmes.

  7. Impact of physical pre-treatment of source-sorted organic fraction of municipal solid waste on greenhouse-gas emissions and the economy in a Swedish anaerobic digestion system.

    PubMed

    Carlsson, My; Holmström, David; Bohn, Irene; Bisaillon, Mattias; Morgan-Sagastume, Fernando; Lagerkvist, Anders

    2015-04-01

    Several methods for physical pre-treatments of source sorted organic fraction of municipal solid waste (SSOFMSW) before for anaerobic digestion (AD) are available, with the common feature that they generate a homogeneous slurry for AD and a dry refuse fraction for incineration. The selection of efficient methods relies on improved understanding of how the pre-treatment impacts on the separation and on the slurry's AD. The aim of this study was to evaluate the impact of the performance of physical pre-treatment of SSOFMSW on greenhouse-gas (GHG) emissions and on the economy of an AD system including a biogas plant with supplementary systems for heat and power production in Sweden. Based on the performance of selected Swedish facilities, as well as chemical analyses and BMP tests of slurry and refuse, the computer-based evaluation tool ORWARE was improved as to accurately describe mass flows through the physical pre-treatment and anaerobic degradation. The environmental and economic performance of the evaluated system was influenced by the TS concentration in the slurry, as well as the distribution of incoming solids between slurry and refuse. The focus to improve the efficiency of these systems should primarily be directed towards minimising the water addition in the pre-treatment provided that this slurry can still be efficiently digested. Second, the amount of refuse should be minimised, while keeping a good quality of the slurry. Electricity use/generation has high impact on GHG emissions and the results of the study are sensitive to assumptions of marginal electricity and of electricity use in the pre-treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Improvement of anaerobic digestion of sewage sludge through microwave pre-treatment.

    PubMed

    Serrano, A; Siles, J A; Martín, M A; Chica, A F; Estévez-Pastor, F S; Toro-Baptista, E

    2016-07-15

    Sewage sludge generated in the activated sludge process is a polluting waste that must be treated adequately to avoid important environmental impacts. Traditional management methods, such as landfill disposal or incineration, are being ruled out due to the high content in heavy metal, pathogens, micropolluting compounds of the sewage sludge and the lack of use of resources. Anaerobic digestion could be an interesting treatment, but must be improved since the biomethanisation of sewage sludge entails low biodegradability and low methane production. A microwave pre-treatment at pilot scale is proposed to increase the organic matter solubilisation of sewage sludge and enhance the biomethanisation yield. The operational variables of microwave pre-treatment (power and specific energy applied) were optimised by analysing the physicochemical characteristics of sewage sludge (both total and soluble fraction) under different pre-treatment conditions. According to the variation in the sCOD and TN concentration, the optimal operation variables of the pre-treatment were fixed at 20,000 J/g TS and 700 W. A subsequent anaerobic digestion test was carried out with raw and pre-treated sewage sludge under different conditions (20,000 J/g TS and 700 W; 20,000 J/g TS and 400 W; and 30,000 J/g TS and 400 W). Although stability was maintained throughout the process, the enhancement in the total methane yield was not high (up to 17%). Nevertheless, very promising improvements were determined for the kinetics of the process, where the rG and the OLR increased by 43% and 39%, respectively, after carrying out a pre-treatment at 20,000 J/g TS and 700 W. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Bioelectricity Generation and Bioremediation of an Azo-Dye in a Microbial Fuel Cell Coupled Activated Sludge Process

    PubMed Central

    Khan, Mohammad Danish; Abdulateif, Huda; Ismail, Iqbal M.; Sabir, Suhail; Khan, Mohammad Zain

    2015-01-01

    Simultaneous bioelectricity generation and dye degradation was achieved in the present study by using a combined anaerobic-aerobic process. The anaerobic system was a typical single chambered microbial fuel cell (SMFC) which utilizes acid navy blue r (ANB) dye along with glucose as growth substrate to generate electricity. Four different concentrations of ANB (50, 100, 200 and 400 ppm) were tested in the SMFC and the degradation products were further treated in an activated sludge post treatment process. The dye decolorization followed pseudo first order kinetics while the negative values of the thermodynamic parameter ∆G (change in Gibbs free energy) shows that the reaction proceeds with a net decrease in the free energy of the system. The coulombic efficiency (CE) and power density (PD) attained peak values at 10.36% and 2,236 mW/m2 respectively for 200 ppm of ANB. A further increase in ANB concentrations results in lowering of cell potential (and PD) values owing to microbial inhibition at higher concentrations of toxic substrates. Cyclic voltammetry studies revealed a perfect redox reaction was taking place in the SMFC. The pH, temperature and conductivity remain 7.5–8.0, 27(±2°C and 10.6–18.2 mS/cm throughout the operation. The biodegradation pathway was studied by the gas chromatography coupled with mass spectroscopy technique, suggested the preferential cleavage of the azo bond as the initial step resulting in to aromatic amines. Thus, a combined anaerobic-aerobic process using SMFC coupled with activated sludge process can be a viable option for effective degradation of complex dye substrates along with energy (bioelectricity) recovery. PMID:26496083

  10. Bioelectricity Generation and Bioremediation of an Azo-Dye in a Microbial Fuel Cell Coupled Activated Sludge Process.

    PubMed

    Khan, Mohammad Danish; Abdulateif, Huda; Ismail, Iqbal M; Sabir, Suhail; Khan, Mohammad Zain

    2015-01-01

    Simultaneous bioelectricity generation and dye degradation was achieved in the present study by using a combined anaerobic-aerobic process. The anaerobic system was a typical single chambered microbial fuel cell (SMFC) which utilizes acid navy blue r (ANB) dye along with glucose as growth substrate to generate electricity. Four different concentrations of ANB (50, 100, 200 and 400 ppm) were tested in the SMFC and the degradation products were further treated in an activated sludge post treatment process. The dye decolorization followed pseudo first order kinetics while the negative values of the thermodynamic parameter ∆G (change in Gibbs free energy) shows that the reaction proceeds with a net decrease in the free energy of the system. The coulombic efficiency (CE) and power density (PD) attained peak values at 10.36% and 2,236 mW/m2 respectively for 200 ppm of ANB. A further increase in ANB concentrations results in lowering of cell potential (and PD) values owing to microbial inhibition at higher concentrations of toxic substrates. Cyclic voltammetry studies revealed a perfect redox reaction was taking place in the SMFC. The pH, temperature and conductivity remain 7.5-8.0, 27(±2°C and 10.6-18.2 mS/cm throughout the operation. The biodegradation pathway was studied by the gas chromatography coupled with mass spectroscopy technique, suggested the preferential cleavage of the azo bond as the initial step resulting in to aromatic amines. Thus, a combined anaerobic-aerobic process using SMFC coupled with activated sludge process can be a viable option for effective degradation of complex dye substrates along with energy (bioelectricity) recovery.

  11. The influence of the Tribulus terrestris extract on the parameters of the functional preparedness and athletes' organism homeostasis.

    PubMed

    Milasius, K; Dadeliene, R; Skernevicius, Ju

    2009-01-01

    The influence of the Tribulus terrestris extract on the parameters of the functional preparadness and athletes' organism homeostase was investigated. It was established the positive impact of dietary supplement "Tribulus" (Optimum Nutrition, U.S.A.) using per 1 capsule 3 times a day during 20 days on athletes' physical power in various energy producing zones: anaerobic alactic muscular power and anaerobic alactic glycolytic power statistically reliable increased. Tribulus terrestris extract, after 20 days of consuming it, did not have essential effect on erythrocytes, haemoglobin and thrombocytes indices. During the experimental period statistically importantly increased percentage of granulocytes and decreased percentage of leucocytes show negative impact of this food supplement on changes of leucocytes formula in athletes' blood. Creatinkinase concentration in athletes' blood statistically importantly has increased and creatinine amount has had a tendency to decline during 20 days period of consuming Tribulus terrestris extract. The declining tendency of urea, cholesterol and bilirubin concentrations has appeared. The concentration of blood testosterone increased statistically reliable during the first half (10 days) of the experiment; it did not grow during the next 10 days while consuming Tribulus still.

  12. The influence of SRT on phosphorus removal and sludge characteristics in the HA-A/A-MCO sludge reduction process

    NASA Astrophysics Data System (ADS)

    Zuo, N.; Ji, F. Y.

    2013-02-01

    By researching the influence of sludge age (SRT) on phosphorous removal and sludge characteristics in the HA-A/A-MCO (hydrolysis-acidification-anaerobic/anoxic-multistep continuous oxic tank) process, which has the effect of simultaneous phosphorous and nitrogen removal and sludge reduction, it is found that extended SRT is helpful for improving the ability of anaerobic phosphorous release and chemical recovery of phosphate, but the hosphorous removal efficiency is not affected. Extended SRT causes the system to have even more active sludge; it can also lead to the system having a powerful ability of biochemical reaction by using superiority of concentration. Meanwhile, extended SRT can still reduce sludge yield. Extended SRT cannot make soluble metabolic product (SMP) accumulate in the reactor, so that the pollutant removal power is reduced; it also cannot affect the activity of the sludge. However, extended SRT is able to make the coagulation of the sludge hard, and cause the sludge volume index value increase, but cannot cause sludge bulking.

  13. Metformin improves performance in high-intensity exercise, but not anaerobic capacity in healthy male subjects.

    PubMed

    Learsi, S K; Bastos-Silva, V J; Lima-Silva, A E; Bertuzzi, R; De Araujo, G G

    2015-10-01

    The aim of this study was to determine the ergogenic effects of metformin in high-intensity exercise, as well as its effects on anaerobic capacity, in healthy and physically active men. Ten subjects (mean (± standard deviation) maximal oxygen uptake (V˙O2max ) 38.6 ± 4.5 mL/kg per min) performed the following tests in a cycle ergometer: (i) an incremental test; (ii) six submaximal constant workload tests at 40%-90% (V˙O2max ); and (iii) two supramaximal tests (110% (V˙O2max ). Metformin (500 mg) or placebo was ingested 60 min before the supramaximal test. There were no significant differences between the placebo and metformin groups in terms of maximum accumulated oxygen deficit (2.8 ± 0.6 vs 3.0 ± 0.8 L, respectively; P = 0.08), lactate concentrations (7.8 ± 2.6 vs 7.5 ± 3.0 mmol/L, respectively; P = 0.75) or O2 consumed in either the last 30 s of exercise (40.4 ± 4.4 vs 39.9 ± 4.0 mL/kg per min, respectively; P = 0.35) or the first 110 s of exercise (29.0 ± 2.5 vs 29.5 ± 3.0 mL/kg per min, respectively; P = 0.42). Time to exhaustion was significantly higher after metformin than placebo ingestion (191 ± 33 vs 167 ± 32 s, respectively; P = 0.001). The fast component of V˙O2 recovery was higher in the metformin than placebo group (12.71 vs 12.18 mL/kg per min, respectively; P = 0.025). Metformin improved performance and anaerobic alactic contribution during high-intensity exercise, but had no effect on overall anaerobic capacity in healthy subjects. © 2015 Wiley Publishing Asia Pty Ltd.

  14. In Vitro Activities of Faropenem against 579 Strains of Anaerobic Bacteria

    PubMed Central

    Wexler, Hannah M.; Molitoris, Denise; St. John, Shahera; Vu, Ann; Read, Erik K.; Finegold, Sydney M.

    2002-01-01

    The activity of faropenem, a new oral penem, was tested against 579 strains of anaerobic bacteria by using the NCCLS-approved reference method. Drugs tested included amoxicillin-clavulanate, cefoxitin, clindamycin, faropenem, imipenem, and metronidazole. Of the 176 strains of Bacteroides fragilis group isolates tested, two isolates had faropenem MICs of 64 μg/ml and imipenem MICs of >32 μg/ml. Faropenem had an MIC of 16 μg/ml for an additional isolate of B. fragilis; this strain was sensitive to imipenem (MIC of 1 μg/ml). Both faropenem and imipenem had MICs of ≤4 μg/ml for all isolates of Bacteroides capillosus (10 isolates), Bacteroides splanchnicus (13 isolates), Bacteroides ureolyticus (11 isolates), Bilophila wadsworthia (11 isolates), Porphyromonas species (42 isolates), Prevotella species (78 isolates), Campylobacter species (25 isolates), Sutterella wadsworthensis (11 isolates), Fusobacterium nucleatum (19 isolates), Fusobacterium mortiferum/varium (20 isolates), and other Fusobacterium species (9 isolates). Faropenem and imipenem had MICs of 16 to 32 μg/ml for two strains of Clostridium difficile; the MICs for all other strains of Clostridium tested (69 isolates) were ≤4 μg/ml. Faropenem had MICs of 8 and 16 μg/ml, respectively, for two strains of Peptostreptococcus anaerobius (MICs of imipenem were 2 μg/ml). MICs were ≤4 μg/ml for all other strains of gram-positive anaerobic cocci (53 isolates) and non-spore-forming gram-positive rods (28 isolates). Other results were as expected and reported in previous studies. No metronidazole resistance was seen in gram-negative anaerobes other than S. wadsworthensis (18% resistant); 63% of gram-positive non-spore-forming rods were resistant. Some degree of clindamycin resistance was seen in most of the groups tested. PMID:12384389

  15. Cardiovascular testing in Fabry disease: exercise capacity reduction, chronotropic incompetence and improved anaerobic threshold after enzyme replacement.

    PubMed

    Lobo, T; Morgan, J; Bjorksten, A; Nicholls, K; Grigg, L; Centra, E; Becker, G

    2008-06-01

    The aim of this study was to document exercise capacity and serial electrocardiogram and echocardiograph findings in a cohort of Australian patients with Fabry disease, in relation to their history of enzyme replacement therapy (ERT). Fabry disease has multifactorial effects on the cardiovascular system. Most previous studies have focused on electrocardiographic and echocardiographic parameters. Exercise capacity can be used as an integrated measure of cardiovascular function and allows the effects of treatment to be monitored. A total of 38 patients (30 men and 8 women) with Fabry disease were monitored by 12-lead electrocardiograms every 6-12 months, and by annual standardized-protocol echocardiograms. Bicycle stress tests with VO(2) max measurement and once-only 6 minutes' walk tests were also carried out in subsets of patients whose general health status allowed testing. Seventy per cent of patients met electrocardiogram criteria for left ventricular hypertrophy. Left ventricular hypertrophy on echocardiograph was present in 64% of patients (80% of men). Exercise capacity was reduced in patients with Fabry disease compared with that predicted from normative population data. Mild improvement in anaerobic threshold was seen in the first year of ERT (14.1 +/- 3.0 to 15.8 +/- 3.0, P = 0.02), but no consistent further increase was seen beyond the first year. Most patients had resting bradycardia, with impaired ability to increase heart rate during exercise. Serial testing on ERT showed an improvement in anaerobic threshold but no significant change in VO(2) max. Male patients with Fabry disease were unable to attain predicted maximal heart rate on exercise or to achieve normal exercise levels. ERT was associated with a small improvement in anaerobic threshold over the first year.

  16. Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women.

    PubMed

    Higa, M N; Silva, E; Neves, V F C; Catai, A M; Gallo, L; Silva de Sá, M F

    2007-04-01

    Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 +/- 2.63 years old) and 16 postmenopausal (57 +/- 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg(-1) min(-1)), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg(-1) min(-1)) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (rs = 0.75) and VCO2 (rs = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.

  17. Effect of alkaline microwaving pretreatment on anaerobic digestion and biogas production of swine manure.

    PubMed

    Yu, Tao; Deng, Yihuan; Liu, Hongyu; Yang, Chunping; Wu, Bingwen; Zeng, Guangming; Lu, Li; Nishimura, Fumitake

    2017-05-10

    Microwave assisted with alkaline (MW-A) condition was applied in the pretreatment of swine manure, and the effect of the pretreatment on anaerobic treatment and biogas production was evaluated in this study. The two main microwaving (MW) parameters, microwaving power and reaction time, were optimized for the pretreatment. Response surface methodology (RSM) was used to investigate the effect of alkaline microwaving process for manure pretreatment at various values of pH and energy input. Results showed that the manure disintegration degree was maximized of 63.91% at energy input of 54 J/g and pH of 12.0, and variance analysis indicated that pH value played a more important role in the pretreatment than in energy input. Anaerobic digestion results demonstrated that MW-A pretreatment not only significantly increased cumulative biogas production, but also shortened the duration for a stable biogas production rate. Therefore, the alkaline microwaving pretreatment could become an alternative process for effective treatment of swine manure.

  18. Simultaneous degradation of toxic refractory organic pesticide and bioelectricity generation using a soil microbial fuel cell.

    PubMed

    Cao, Xian; Song, Hai-Liang; Yu, Chun-Yan; Li, Xian-Ning

    2015-01-01

    In this study, the soil microbial fuel cells (MFCs) were constructed in the topsoil contaminated with toxic refractory organic pesticide, hexachlorobenzene (HCB). The performance of electricity generation and HCB degradation in the soil-MFCs were investigated. The HCB degradation pathway was analyzed based on the determination of degradation products and intermediates. Experimental results showed that the HCB removal efficiencies in the three groups (soil MFCs group, open circuit control group and no adding anaerobic sludge blank group) were 71.15%, 52.49% and 38.92%, respectively. The highest detected power density was 77.5 mW/m(2) at the external resistance of 1000 Ω. HCB was degraded via the reductive dechlorination pathway in the soil MFC under anaerobic condition. The existence of the anode promoted electrogenic bacteria to provide more electrons to increase the metabolic reactions rates of anaerobic bacteria was the main way which could promote the removal efficiencies of HCB in soil MFC. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Knee and ankle strength and lower extremity power in adolescent female ballet dancers.

    PubMed

    Kenne, Ellinor; Unnithan, Viswanath B

    2008-01-01

    The aims of this study were twofold: (1) to compare the strength of four muscle groups of the lower limb (quadriceps [Q], hamstrings [H], plantar flexors [PF], and dorsiflexors [DF]) between female adolescent ballet dancers (BALs) and basketball players (BBs) over three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) and two types of contraction (eccentric and concentric); and (2) to compare peak and mean power between the BALs and BBs. Eleven BALs (age: 15.8 +/- 1.2 years; stature: 163.9 +/- 6.2 cm; body mass: 56.3 +/- 5.7 kg; Tanner stage 4: N=10, stage 5: N=1) and ten BBs (age: 15.8 +/- 1.0 years; stature: 172.5 +/- 5.8 cm; body mass: 63.2 +/- 10.0 kg; Tanner stage 4: N=7, stage 5: N=3) volunteered to participate. Each participant performed one habituation session and one testing session on a Biodex isokinetic dynamometer to determine peak torque. Three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) were used for each muscle group. To determine absolute and relative peak and mean power, participants performed a 30 second anaerobic Wingate test on a cycle ergometer. There were no significant differences in peak torque for Q, H, PF, and DF between the groups. Basketball players produced greater absolute peak power [569.7 +/- 82.2 vs. 454.6 +/- 79.3 W (p < .05)], relative peak power [9.1 +/- 1.3 vs. 8.1 +/- 1.0 W/kg body mass (p < .05)], absolute mean power [428.4 +/- 53.9 vs. 333.7 +/- 68.2 W (p < .05)] and relative mean power [6.83 +/- 0.7 vs. 5.9 +/- 0.7 W/kg (p < .05)] than BALs. Ballet dancers and BBs had similar isokinetically measured lower extremity muscular strength, but BALs generated lower levels of peak power and mean power compared to BBs.

  20. Post-prandial carbohydrate ingestion during 1-h of moderate-intensity, intermittent cycling does not improve mood, perceived exertion, or subsequent power output in recreationally-active exercisers

    PubMed Central

    2013-01-01

    Background This study compared the effects of ingesting water (W), a flavored carbohydrate-electrolyte (CE) or a flavored non-caloric electrolyte (NCE) beverage on mood, ratings of perceived exertion (RPE), and sprint power during cycling in recreational exercisers. Methods Men (n = 23) and women (n = 13) consumed a 24–h standardized diet and reported 2–4 h post-prandial for all test sessions. After a familiarization session, participants completed 50 min of stationary cycling in a warm environment (wet bulb globe temperature = 25.0°C) at ~ 60-65% of heart rate reserve (146 ± 4 bpm) interspersed with 5 rest periods of 2 min each. During exercise, participants consumed W, CE, or NCE, served in a counterbalanced cross-over design. Beverage volume was served in 3 aliquots equaling each individual’s sweat losses (mean 847 ± 368 mL) during the familiarization session. Profiles of Mood States questionnaires (POMS) were administered and blood glucose levels were determined pre- and post- sub-maximal cycling. Following sub-maximal exercise, participants completed 3 30–s Wingate anaerobic tests (WAnT) with 2.5 min rest between tests to assess performance. Results Blood glucose was higher (p <  0.05) after 50 min of submaximal cycling just prior to the WAnT for CE (6.1 ± 1.7 mmol/L) compared to W (4.9 ± 1.5 mmol/L) and NCE (4.6 ± 1.2 mmol/L). Nonetheless, there were no differences among treatments in peak (642 ± 153, 635 ± 143, 650 ± 141 watts for W, NCE, and CE, respectively; p  =  0.44) or mean (455 ± 100, 458 ± 95, 454 ± 95 watts for W, NCE, and CE, respectively; p = 0.62) power for the first WAnT or mean (414 ± 92, 425 ± 85, 423 ± 82 watts, respectively; p = 0.13) power output averaged across all 3 WAnT. Likewise, RPE during submaximal exercise, session RPE, and fatigue and vigor assessed by POMS did not differ among beverage treatments (p > 0.05). Conclusions Carbohydrate ingestion consumed by recreational exercisers during a 1–h, moderate-intensity aerobic workout did not alter mood or perceived exertion, nor did it affect subsequent anaerobic performance under the conditions of this study. Drinking caloric sport beverages does not benefit recreational exercisers in a non-fasted state. PMID:23347391

  1. Kinetic modelling of anaerobic hydrolysis of solid wastes, including disintegration processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Gen, Santiago; Sousbie, Philippe; Rangaraj, Ganesh

    2015-01-15

    Highlights: • Fractionation of solid wastes into readily and slowly biodegradable fractions. • Kinetic coefficients estimation from mono-digestion batch assays. • Validation of kinetic coefficients with a co-digestion continuous experiment. • Simulation of batch and continuous experiments with an ADM1-based model. - Abstract: A methodology to estimate disintegration and hydrolysis kinetic parameters of solid wastes and validate an ADM1-based anaerobic co-digestion model is presented. Kinetic parameters of the model were calibrated from batch reactor experiments treating individually fruit and vegetable wastes (among other residues) following a new protocol for batch tests. In addition, decoupled disintegration kinetics for readily and slowlymore » biodegradable fractions of solid wastes was considered. Calibrated parameters from batch assays of individual substrates were used to validate the model for a semi-continuous co-digestion operation treating simultaneously 5 fruit and vegetable wastes. The semi-continuous experiment was carried out in a lab-scale CSTR reactor for 15 weeks at organic loading rate ranging between 2.0 and 4.7 g VS/L d. The model (built in Matlab/Simulink) fit to a large extent the experimental results in both batch and semi-continuous mode and served as a powerful tool to simulate the digestion or co-digestion of solid wastes.« less

  2. Photodynamic therapy to treat periimplantitis.

    PubMed

    Bombeccari, Gian Paolo; Guzzi, Gianpaolo; Gualini, Federico; Gualini, Sara; Santoro, Franco; Spadari, Francesco

    2013-12-01

    : Periimplantitis is a bacterial complication after dental implants implantation. Photodynamic therapy (PDT) implies the use of low-power laser in combination with appropriate photosensitizer to increase the detoxification of the implant surfaces. Little information exists about PDT in the treatment of periimplantitis. A randomized comparative case-control study has been conducted with 20 patients and 20 controls to compare the efficacy of antimicrobial PDT versus surgical therapy in patients with periimplantitis, who have received dental implants with rough surfaces. In the surgery group, mucoperiosteal flap surgery was used with scaling on implant surfaces and debridement of granulation tissue. Microbiologic testing was evaluated before and after intervention treatment, at 12 and 24 weeks in the study subjects. Total anaerobic counts of bacteria did not differ significantly between patients assigned to receive PDT and those assigned to receive surgical therapy (mean, 95.2% and 80.85%, respectively). PDT was associated with a significant decrease in bleeding scores (P = 0.02) as well as inflammatory exudation (P = 0.001). Treatment with PDT in patients with periimplantitis was not associated with major reduction of total anaerobic bacteria on the rough surfaces of dental implants as compared with surgical therapy. A significantly lower proinflammatory index of periimplantitis was observed in the PDT group at 24 weeks of follow-up.

  3. Prevalence and antimicrobial susceptibilities of anaerobic bacteria isolated from perforated corneal ulcers by culture and multiplex PCR: an evaluation in cases with keratitis and endophthalmitis.

    PubMed

    Tokman, Hrisi Bahar; İskeleli, Güzin; Dalar, Zeynep Güngördü; Kangaba, Achille Aime; Demirci, Mehmet; Akay, Hatice K; Borsa, Bariş Ata; Algingil, Reyhan Çalişkan; Kocazeybek, Bekir S; Torun, Müzeyyen Mamal; Kiraz, Nuri

    2014-01-01

    Anaerobic bacteria play an important role in eye infections; however, there is limited epidemiologic data based on the the role of these bacteria in the etiology of keratitis and endophthalmitis. The aim of this re- search is to determine the prevalence of anaerobic bacteria in perforated corneal ulcers of patients with keratitis and endophthalmitis and to evaluate their antimicrobial susceptibilities. Corneal scrapings were taken by the ophthalmologist using sterile needles. For the isolation of anaerobic bacteria, samples were inoculated on specific media and were incubated under anaerobic conditions obtained with Anaero-Gen (Oxoid & Mitsubishi Gas Company) in anaerobic jars (Oxoid USA, Inc. Columbia, MD, USA). The molecular identification of anaerobic bacteria was performed by multiplex PCR and the susceptibilities of an- aerobic bacteria to penicillin, chloramphenicol, and clindamycin were determined with the E test (bioMerieux). 51 strains of anaerobic bacteria belonging to four different genuses were detected by multiplex PCR and only 46 strains were isolated by culture. All of them were found susceptible to chloramphenicol whereas penicillin resistance was found in 13.3% of P.anaerobius strains, clindamycin resistance was found in 34.8% of P.acnes and 13.3% of P. anaerobius strains. Additionnaly, one strain of P. granulosum was found resistant to clindamycin, one strain of B. fragilis and one strain of P.melaninogenica were found resistant to penicillin and clindamycin. Routine analyses of anaerobes in perforated corneal ulcers is inevitable and usage of appropriate molecular methods, for the detection of bacteria responsible from severe infections which might not be deter- mined by cultivation, may serve for the early decision of the appropriate treatment. Taking into account the in- creasing antimicrobial resistance of anaerobic bacteria, alternative eye specific antibiotics effective against anaer- obes are needed to achieve a successful treatment.

  4. Comparison of Leachate Quality from Aerobic and Anaerobic Municipal Solid Waste Bioreactors

    NASA Astrophysics Data System (ADS)

    Borglin, S. E.; Hazen, T. C.; Oldenburg, C. M.

    2002-12-01

    Municipal solid waste landfills are becoming a drain on the resources of local municipalities as the requirements for stabilization and containment become increasingly stringent. Current regulations limit the moisture in the landfill to minimize leachate production and lower the potential for release of leachate to the environment. Recent research has shown that addition and recycling of moisture in the waste optimizes the biodegradation of stabilization and also provides a means for leachate treatment. This study compares the characteristics of leachate produced from aerobic and anaerobic laboratory bioreactors, and leachate collected from a full-scale anaerobic bioreactor. The laboratory reactors consisted of 200-liter tanks filled with fresh waste materials with the following conditions: (a) aerobic (air injection with leachate recirculation), (b) anaerobic (leachate recirculation). The leachate from the reactors was monitored for metals, nutrients, organic carbon, and microbiological activity for up to 500 days. Leachate from the aerobic tank had significantly lower concentrations of all potential contaminants, both organic and metal, after only a few weeks of operation. Metals leaching was low throughout the test period for the aerobic tanks, and decreased over time for the anaerobic tanks. Organic carbon as measured by BOD, COD, TOC, and COD were an order of magnitude higher in the leachate from the anaerobic system. Microbiological assessment by lipid analysis, enzyme activity assays, and cell counts showed high biomass and diversity in both the aerobic and anaerobic bioreactors, with higher activity in the anaerobic leachate. Results from the full-scale anaerobic bioreactor were not significantly different from those of the laboratory anaerobic bioreactor. The reduction in noxious odors was a significant advantage of the aerobic system. These results suggest that aerobic management of landfills could reduce or eliminate the need for leachate treatment systems, reduce odor, and reduce the need for extensive containment strategies. This work was supported by Laboratory Directed Research and Development Funds at Lawrence Berkeley National Laboratory under Department of Energy Contract No. DE-AC03-76SF00098.

  5. Partitioning the metabolic scope: the importance of anaerobic metabolism and implications for the oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis

    PubMed Central

    Ejbye-Ernst, Rasmus; Michaelsen, Thomas Y.; Tirsgaard, Bjørn; Wilson, Jonathan M.; Jensen, Lasse F.; Steffensen, John F.; Pertoldi, Cino; Aarestrup, Kim; Svendsen, Jon C.

    2016-01-01

    Ongoing climate change is predicted to affect the distribution and abundance of aquatic ectotherms owing to increasing constraints on organismal physiology, in particular involving the metabolic scope (MS) available for performance and fitness. The oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis prescribes MS as an overarching benchmark for fitness-related performance and assumes that any anaerobic contribution within the MS is insignificant. The MS is typically derived from respirometry by subtracting standard metabolic rate from the maximal metabolic rate; however, the methodology rarely accounts for anaerobic metabolism within the MS. Using gilthead sea bream (Sparus aurata) and Trinidadian guppy (Poecilia reticulata), this study tested for trade-offs (i) between aerobic and anaerobic components of locomotor performance; and (ii) between the corresponding components of the MS. Data collection involved measuring oxygen consumption rate at increasing swimming speeds, using the gait transition from steady to unsteady (burst-assisted) swimming to detect the onset of anaerobic metabolism. Results provided evidence of the locomotor performance trade-off, but only in S. aurata. In contrast, both species revealed significant negative correlations between aerobic and anaerobic components of the MS, indicating a trade-off where both components of the MS cannot be optimized simultaneously. Importantly, the fraction of the MS influenced by anaerobic metabolism was on average 24.3 and 26.1% in S. aurata and P. reticulata, respectively. These data highlight the importance of taking anaerobic metabolism into account when assessing effects of environmental variation on the MS, because the fraction where anaerobic metabolism occurs is a poor indicator of sustainable aerobic performance. Our results suggest that without accounting for anaerobic metabolism within the MS, studies involving the OCLTT hypothesis could overestimate the metabolic scope available for sustainable activities and the ability of individuals and species to cope with climate change. PMID:27293766

  6. Short-term germ-killing effect of sugar-sweetened cinnamon chewing gum on salivary anaerobes associated with halitosis.

    PubMed

    Zhu, Min; Carvalho, Regina; Scher, Aubrey; Wu, Christine D

    2011-01-01

    The present study investigated the short-term germ-killing effect of sugar-sweetened cinnamon chewing gum on total and H2S-producing salivary anaerobes. Fifteen healthy adult subjects were recruited in the double-blind, crossover clinical study. The three test chewing gums included: 1) sugared chewing gum containing cinnamic aldehyde and natural flavors (CinA+); 2) sugared chewing gum without cinnamic aldehyde but with natural flavors (CinA-); and 3) non-sugared chewing gum base (GB) without any flavors and without cinnamic aldehyde. A three-day "washout" period followed each treatment. Each subject chewed gum under supervision for 20 minutes at 60 chews/minute. Unstimulated whole saliva samples were collected before the subjects chewed the gum and at 20 minutes after expectoration of the gum. All saliva samples were serially diluted, plated on blood agar or agar plates that select for bacteria producing H2S, incubated anaerobically for three days, and enumerated for viable colony counts of total and H2S-producing salivary anaerobes. Significant reductions in total salivary anaerobes (p < 0.01) and H2S-producing salivary anaerobes (p < 0.01) were observed 20 minutes after subjects chewed the CinA+ gum. The chewing of CinA- gum also significantly reduced total salivary anaerobes (p < 0.05) and H2S-producing salivary anaerobes (p < 0.05). However, no statistically significant difference in germ-killing effect was detected between the CinA+ and CinA- gums, although there was a numeric difference. The chewing of a gum base (GB) alone did not result in a significant reduction in the total or H2S-producing salivary anaerobes (p > 0.05). The commercially available sugar-sweetened cinnamon chewing gum may benefit halitosis by reducing volatile sulfur compounds producing anaerobes in the oral cavity.

  7. Potential use of the organic fraction of municipal solid waste in anaerobic co-digestion with wastewater in submerged anaerobic membrane technology.

    PubMed

    Moñino, P; Jiménez, E; Barat, R; Aguado, D; Seco, A; Ferrer, J

    2016-10-01

    Food waste was characterized for its potential use as substrate for anaerobic co-digestion in a submerged anaerobic membrane bioreactor pilot plant that treats urban wastewater (WW). 90% of the particles had sizes under 0.5mm after grinding the food waste in a commercial food waste disposer. COD, nitrogen and phosphorus concentrations were 100, 2 and 20 times higher in food waste than their average concentrations in WW, but the relative flow contribution of both streams made COD the only pollutant that increased significantly when both substrates were mixed. As sulphate concentration in food waste was in the same range as WW, co-digestion of both substrates would increase the COD/SO4-S ratio and favour methanogenic activity in anaerobic treatments. The average methane potential of the food waste was 421±15mLCH4g(-1)VS, achieving 73% anaerobic biodegradability. The anaerobic co-digestion of food waste with WW is expected to increase methane production 2.9-fold. The settleable solids tests and the particle size distribution analyses confirmed that both treatment lines of a conventional WWTP (water and sludge lines) would be clearly impacted by the incorporation of food waste into its influent. Anaerobic processes are therefore preferred over their aerobic counterparts due to their ability to valorise the high COD content to produce biogas (a renewable energy) instead of increasing the energetic costs associated with the aeration process for aerobic COD oxidation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Heterologous production of Pseudomonas aeruginosa rhamnolipid under anaerobic conditions for microbial enhanced oil recovery.

    PubMed

    Zhao, F; Shi, R; Zhao, J; Li, G; Bai, X; Han, S; Zhang, Y

    2015-02-01

    The ex situ application of rhamnolipid to enhance oil recovery is costly and complex in terms of rhamnolipid production and transportation, while in situ production of rhamnolipid is restricted by the oxygen-deficient environments of oil reservoirs. To overcome the oxygen-limiting conditions and to circumvent the complex regulation of rhamnolipid biosynthesis in Pseudomonas aeruginosa, an engineered strain Pseudomonas stutzeri Rhl was constructed for heterologous production of rhamnolipid under anaerobic conditions. The rhlABRI genes for rhamnolipid biosynthesis were cloned into a facultative anaerobic strain Ps. stutzeri DQ1 to construct the engineered strain Rhl. Anaerobic production of rhamnolipid was confirmed by thin layer chromatography and Fourier transform infrared analysis. Rhamnolipid product reduced the air-water surface tension to 30.3 mN m(-1) and the oil-water interfacial tension to 0.169 mN m(-1). Rhl produced rhamnolipid of 1.61 g l(-1) using glycerol as the carbon source. Rhl anaerobic culture emulsified crude oil up to EI24 ≈ 74. An extra 9.8% of original crude oil was displaced by Rhl in the core flooding test. Strain Rhl achieved anaerobic production of rhamnolipid and worked well for enhanced oil recovery in the core flooding model. The rhamnolipid produced by Rhl was similar to that of the donor strain SQ6. This is the first study to achieve anaerobic and heterologous production of rhamnolipid. Results demonstrated the potential feasibility of Rhl as a promising strain to enhance oil recovery through anaerobic production of rhamnolipid. © 2014 The Society for Applied Microbiology.

  9. A multi-criteria ranking of different technologies for the anaerobic digestion for energy recovery of the organic fraction of municipal solid wastes.

    PubMed

    Karagiannidis, A; Perkoulidis, G

    2009-04-01

    This paper describes a conceptual framework and methodological tool developed for the evaluation of different anaerobic digestion technologies suitable for treating the organic fraction of municipal solid waste, by introducing the multi-criteria decision support method Electre III and demonstrating its related applicability via a test application. Several anaerobic digestion technologies have been proposed over the last years; when compared to biogas recovery from landfills, their advantage is the stability in biogas production and the stabilization of waste prior to final disposal. Anaerobic digestion technologies also show great adaptability to a broad spectrum of different input material beside the organic fraction of municipal solid waste (e.g. agricultural and animal wastes, sewage sludge) and can also be used in remote and isolated communities, either stand-alone or in conjunction to other renewable energy sources. Main driver for this work was the preliminary screening of such methods for potential application in Hellenic islands in the municipal solid waste management sector. Anaerobic digestion technologies follow different approaches to the anaerobic digestion process and also can include production of compost. In the presented multi-criteria analysis exercise, Electre III is implemented for comparing and ranking 5 selected alternative anaerobic digestion technologies. The results of a performed sensitivity analysis are then discussed. In conclusion, the performed multi-criteria approach was found to be a practical and feasible method for the integrated assessment and ranking of anaerobic digestion technologies by also considering different viewpoints and other uncertainties of the decision-making process.

  10. Pilot plant experience on anaerobic codigestion of source selected OFMSW and sewage sludge.

    PubMed

    Cabbai, Valentina; De Bortoli, Nicola; Goi, Daniele

    2016-03-01

    Anaerobic codigestion of source selected organic fraction of municipal solid waste (SS-OFMSW) and sewage sludge may be one of the most viable solutions to optimize oversized digesters efficiency in wastewater treatment plants. Based on results of BMP tests obtained for sewage sludge and SS-OFMSW, pilot plant tests were carried out by 3.4 m(3) CSTR reactor at mesophilic temperature. A mix of fruit and vegetable waste from wholesale market and canteen waste was used as SS-OFMSW substrate. Tests were conducted applying an OLR (organic loading rate) ramp with 6 different phases until a value of 3.2 kgVS/m(3) d. Feedstock and digestate characteristics, efficiency and process parameters were monitored. The anaerobic codigestion development was stable in each phase: early indicators like VFA (volatile fatty acids) and FOS/TAC ratio were always below instability threshold values. The maximum OLR tested determined a GPR (gas production rate) of 0.95 N m(3)/m(3) d and SGP (specific gas production) of 0.49 N m(3)/kgVS with a VS abatement of 67.3%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Effects of exercise continued until anaerobic threshold on balance performance in male basketball players.

    PubMed

    Erkmen, Nurtekin; Suveren, Sibel; Göktepe, Ahmet Salim

    2012-06-01

    The objective of the present study was to determine the effects of exercise continued until the anaerobic threshold on balance performance in basketball players. Twelve male basketball players (age = 20.92 ± 2.81 years, body height = 192.72 ± 7.61 cm, body mass = 88.09 ± 8.41 kg, training experience = 7.17 ± 3.10 years) volunteered to participate in this study. A Kinesthetic Ability Trainer (KAT 2000 stabilometer) was used to measure the balance performance. Balance tests consisted of static tests on dominant, nondominant and double leg stance. The Bruce Protocol was performed by means of a treadmill. The exercise protocol was terminated when the subject passed the anaerobic threshold. After the exercise protocol, balance measurements were immediately repeated. Statistical differences between pre and post-exercise for dominant, nondominant and double leg stance were determined by the paired samples t-test according to the results of the test of normality. The post-exercise balance score on the dominant leg was significantly higher than pre-exercise (t = -2.758, p < 0.05). No differences existed between pre- and post-exercise in the balance scores of the nondominant leg after the exercise protocol (t = 0.428, p > 0.05). A significant difference was found between pre and post-exercise balance scores in the double leg stance (t = -2.354, p < 0.05). The main finding of this study was that an incremental exercise continued until the anaerobic threshold decreased balance performance on the dominant leg in basketball players, but did not alter it in the nondominant leg.

  12. Chemical structure-based predictive model for methanogenic anaerobic biodegradation potential.

    PubMed

    Meylan, William; Boethling, Robert; Aronson, Dallas; Howard, Philip; Tunkel, Jay

    2007-09-01

    Many screening-level models exist for predicting aerobic biodegradation potential from chemical structure, but anaerobic biodegradation generally has been ignored by modelers. We used a fragment contribution approach to develop a model for predicting biodegradation potential under methanogenic anaerobic conditions. The new model has 37 fragments (substructures) and classifies a substance as either fast or slow, relative to the potential to be biodegraded in the "serum bottle" anaerobic biodegradation screening test (Organization for Economic Cooperation and Development Guideline 311). The model correctly classified 90, 77, and 91% of the chemicals in the training set (n = 169) and two independent validation sets (n = 35 and 23), respectively. Accuracy of predictions of fast and slow degradation was equal for training-set chemicals, but fast-degradation predictions were less accurate than slow-degradation predictions for the validation sets. Analysis of the signs of the fragment coefficients for this and the other (aerobic) Biowin models suggests that in the context of simple group contribution models, the majority of positive and negative structural influences on ultimate degradation are the same for aerobic and methanogenic anaerobic biodegradation.

  13. Decolorization and biogas production by an anaerobic consortium: effect of different azo dyes and quinoid redox mediators.

    PubMed

    Alvarez, L H; Valdez-Espinoza, R; García-Reyes, R B; Olivo-Alanis, D; Garza-González, M T; Meza-Escalante, E R; Gortáres-Moroyoqui, P

    2015-01-01

    The inhibitory effect of azo dyes and quinoid compounds on an anaerobic consortium was evaluated during a decolorization process and biogas production. In addition, the impact of quinoid compounds such as lawsone (LAW) and anthraquinone-2,6-disulfonate (AQDS) on the rate of decolorization of Direct Blue 71 (DB71) was assessed. The anaerobic consortium was not completely inhibited under all tested dye concentrations (0.1-2 mmol l(-1)), evidenced by an active decolorization process and biogas production. The presence of quinoid compounds at different concentrations (4, 8, and 12 mmol l(-1)) also inhibited biogas production compared to the control incubated without the quinoid compounds. In summary, the anaerobic consortium was affected to a greater extent by increasing the quantity of azo dyes or quinoid compounds. Nevertheless, at a lower concentration (1 mmol l(-1)) of quinoid compounds, the anaerobic consortium effectively decolorized 2 mmol l(-1) of DB71, increasing up to 5.2- and 20.4-fold the rate of decolorization with AQDS and LAW, respectively, compared to the control lacking quinoid compounds.

  14. Biosorption of Cu(II) by powdered anaerobic granular sludge from aqueous medium.

    PubMed

    Zhou, Xu; Chen, Chuan; Wang, Aijie; Jiang, Guangming; Liu, Lihong; Xu, Xijun; Yuan, Ye; Lee, Duu-Jung; Ren, Nanqi

    2013-01-01

    Copper(II) biosorption processes by two pre-treated powdered anaerobic granular sludges (PAGS) (original sludges were methanogenic anaerobic granules and denitrifying sulfide removal (DSR) anaerobic granules) were investigated through batch tests. Factors affecting the biosorption process, such as pH, temperature and initial copper concentrations, were examined. Also, the physico-chemical characteristics of the anaerobic sludge were analyzed by Fourier transform infrared spectroscopy, scanning electron microscopy image, surface area and elemental analysis. A second-order kinetic model was applied to describe the biosorption process, and the model could fit the biosorption process. The Freundlich model was used for describing the adsorption equilibrium data and could fit the equilibrium data well. It was found that the methanogenic PAGS was more effective in Copper(II) biosorption process than the DSR PAGS, whose maximum biosorption capacity was 39.6% lower. The mechanisms of the biosorption capacities for different PAGS were discussed, and the conclusion suggested that the environment and biochemical reactions during the growth of biomass may have affected the structure of the PAGS. The methanogenic PAGS had larger specific surface area and more biosorption capacity than the DSR PAGS.

  15. Real-time PCR assays for monitoring anaerobic fungal biomass and population size in the rumen.

    PubMed

    Lwin, Khin Ohnmar; Hayakawa, Mika; Ban-Tokuda, Tomomi; Matsui, Hiroki

    2011-04-01

    The relationship between copy numbers of internal transcribed spacer 1 (ITS1) and biomass or zoospore count of anaerobic fungi was studied to develop a quantitative real-time PCR-based monitoring method for fungal biomass or population in the rumen. Nine fungal strains were used to determine the relationship between ITS1 copy number and fungal biomass. Rumen fluid from three sheep and a cow were used to determine the relationship between ITS1 copy number and fungal population. ITS1 copy number was determined by real-time PCR with a specific primer set for anaerobic fungi. Freeze-dried fungal cells were weighed for fungal biomass. Zoospore counts were determined by the roll-tube method. A positive correlation was observed between both ITS1 copy number and dry weight and ITS1 copy number and zoospore counts, suggesting that the use of ITS1 copy numbers is effective for estimating fungal biomass and population density. On the basis of ITS1 copy numbers, fluctuations in the fungal population in sheep rumen showed that although the values varied among individual animals, the fungal population tended to decrease after feeding. In the present study, a culture-independent method was established that will provide a powerful tool for understanding the ecology of anaerobic fungi in the rumen.

  16. ELECTRICITY GENERATION FROM ANAEROBIC WASTEWATER TREATMENT IN MICROBIAL FUEL CELLS (MFCS) - PHASE I

    EPA Science Inventory

    Municipal wastewater treatment plants represent a huge energy ‘sink’ in the United States. Estimates are that these plants consume up to 3 percent of the total amount of power consumed annually. Ironically, the wastewater is concentrated with materials (carbohydrates) which ...

  17. Cow Power: A Case Study of Renewable Compressed Natural Gas as a Transportation Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mintz, Marianne; Tomich, Matthew

    This case study explores the production and use of renewable compressed natural gas (R-CNG)—derived from the anaerobic digestion (AD) of dairy manure—to fuel 42 heavy-duty milk tanker trucks operating in Indiana, Michigan, Tennessee, and Kentucky.

  18. Anti-anaerobic activity of levofloxacin alone and combined with clindamycin and metronidazole.

    PubMed

    Credito, K L; Jacobs, M R; Appelbaum, P C

    2000-11-01

    Microdilution MICs of levofloxacin against twelve anaerobes ranged between 0.5-8.0 microg/ml and those of clindamycin and metronidazole between 0.008-2.0 and 0.25->16.0 microg/ml, respectively. Combination of levofloxacin with clindamycin and/or metronidazole in time-kill tests led to synergy at levofloxacin concentrations at or below the MIC in 7/12 strains.

  19. A scanning electron microscopic evaluation of in vitro dentinal tubules penetration by selected anaerobic bacteria.

    PubMed

    Siqueira, J F; De Uzeda, M; Fonseca, M E

    1996-06-01

    In vitro root canal dentinal tubule invasion by selected anaerobic bacteria commonly isolated from endodontic infections was evaluated. Dentinal cylinders obtained from bovine incisors were inoculated with bacteria, and microbial penetration into tubules was demonstrated by scanning electron microscopy. The results indicated that all bacterial strains tested were able to penetrate into dentinal tubules, but to different extents.

  20. Effect of initial bulk density on high-solids anaerobic digestion of MSW: General mechanism.

    PubMed

    Caicedo, Luis M; Wang, Hongtao; Lu, Wenjing; De Clercq, Djavan; Liu, Yanjun; Xu, Sai; Ni, Zhe

    2017-06-01

    Initial bulk density (IBD) is an important variable in anaerobic digestion since it defines and optimizes the treatment capacity of a system. This study reveals the mechanism on how IBD might affect anaerobic digestion of waste. Four different IBD values: D 1 (500-700kgm -3 ), D 2 (900-1000kgm -3 ), D 3 (1100-1200kgm -3 ) and D 4 (1200-1400kgm -3 ) were set and tested over a period of 90days in simulated landfill reactors. The main variables affected by the IBD are the methane generation, saturation degree, extraction of organic matter, and the total population of methanogens. The study identified that IBD >1000kgm -3 may have significant effect on methane generation, either prolonging the lag time or completely inhibiting the process. This study provides a new understanding of the anaerobic digestion process in saturated high-solids systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Identification of anaerobic bacteria by Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometry with on-plate formic acid preparation.

    PubMed

    Schmitt, Bryan H; Cunningham, Scott A; Dailey, Aaron L; Gustafson, Daniel R; Patel, Robin

    2013-03-01

    Identification of anaerobic bacteria using phenotypic methods is often time-consuming; methods such as 16S rRNA gene sequencing are costly and may not be readily available. We evaluated 253 clinical isolates of anaerobic bacteria using the Bruker MALDI Biotyper (Bruker Daltonics, Billerica, MA) matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) system with a user-supplemented database and an on-plate formic acid-based preparation method and compared results to those of conventional identification using biochemical testing or 16S rRNA gene sequencing. A total of 179 (70.8%) and 232 (91.7%) isolates were correctly identified to the species and genus levels, respectively, using manufacturer-recommended score cutoffs. MALDI-TOF MS offers a rapid, inexpensive method for identification of anaerobic bacteria.

  2. [Diagnosis and treatment of suppurative processes caused by non-clostridial anaerobic microflora].

    PubMed

    Ofanesian, S S

    1989-06-01

    One hundred and fifty patients suffering from various purulent diseases (60 persons) and postoperative purulent complications (90 persons) caused by nonclostridial anaerobes were examined. Nonclostridial anaerobic bacteria were isolated most frequently in acute mastitis, paraproctitis, and postinfectious abscesses among patients of the first group and after appendectomy and resection of the large intestine among those of the second group. The character of the wound discharge, the location of the focus of infection, the tendency of the purulent process to form a great number of cavities and fistules, bacterioscopy of the native material, etc. help in establishing the diagnosis (before the results of bacteriological tests are obtained). Purulent processes caused by a combination of anaerobic cocci and aerobic flora take a particularly unfavourable course. Antibiotic therapy should consists of high doses of one or two antibiotics combined with metronidazole and nystatin.

  3. Determination of moxifloxacin anaerobic susceptibility breakpoints according to the Clinical and Laboratory Standards Institute guidelines.

    PubMed

    Ambler, Jane; Rennie, Robert; Poupard, James; Koeth, Laura; Stass, Heino; Endermann, Rainer; Choudhri, Shurjeel

    2008-05-01

    A summary of the key data presented to Clinical and Laboratory Standards Institute (CLSI, formerly National Committee for Clinical and Laboratory Standards) in determination of moxifloxacin anaerobic breakpoints is presented. The breakpoint analysis required review of a variety of data, including bacteriologic and clinical outcomes by MIC of anaerobic isolates from prospective clinical trials in patients with complicated intra-abdominal infections, human and animal pharmacokinetic/pharmacodynamic (PK/PD) information and in vitro models, MIC distributions of indicated organisms, and animal model efficacy data for strains with MIC values around prospective breakpoints. The compilation of the various components of this breakpoint analysis supports the US Food and Drug Administration (FDA) and CLSI moxifloxacin anaerobic breakpoints of < or =2 mg/L (susceptible), 4 mg/L (intermediate), and > or =8 mg/L (resistant), and provides information to European investigators for interpretation of MICs prior to establishment of the European Committee on Antimicrobial Susceptibility Testing breakpoints.

  4. Comparison of different liquid anaerobic digestion effluents as inocula and nitrogen sources for solid-state batch anaerobic digestion of corn stover.

    PubMed

    Xu, Fuqing; Shi, Jian; Lv, Wen; Yu, Zhongtang; Li, Yebo

    2013-01-01

    Effluents from three liquid anaerobic digesters, fed with municipal sewage sludge, food waste, or dairy waste, were evaluated as inocula and nitrogen sources for solid-state batch anaerobic digestion of corn stover in mesophilic reactors. Three feedstock-to-effluent (F/E) ratios (i.e., 2, 4, and 6) were tested for each effluent. At an F/E ratio of 2, the reactor inoculated by dairy waste effluent achieved the highest methane yield of 238.5L/kg VS(feed), while at an F/E ratio of 4, the reactor inoculated by food waste effluent achieved the highest methane yield of 199.6L/kg VS(feed). The microbial population and chemical composition of the three effluents were substantially different. Food waste effluent had the largest population of acetoclastic methanogens, while dairy waste effluent had the largest populations of cellulolytic and xylanolytic bacteria. Dairy waste also had the highest C/N ratio of 8.5 and the highest alkalinity of 19.3g CaCO(3)/kg. The performance of solid-state batch anaerobic digestion reactors was closely related to the microbial status in the liquid anaerobic digestion effluents. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Comparative performance evaluation of full-scale anaerobic and aerobic wastewater treatment processes in Brazil.

    PubMed

    von Sperling, M; Oliveira, S C

    2009-01-01

    This article evaluates and compares the actual behavior of 166 full-scale anaerobic and aerobic wastewater treatment plants in operation in Brazil, providing information on the performance of the processes in terms of the quality of the generated effluent and the removal efficiency achieved. The observed results of effluent concentrations and removal efficiencies of the constituents BOD, COD, TSS (total suspended solids), TN (total nitrogen), TP (total phosphorus) and FC (faecal or thermotolerant coliforms) have been compared with the typical expected performance reported in the literature. The treatment technologies selected for study were: (a) predominantly anaerobic: (i) septic tank + anaerobic filter (ST + AF), (ii) UASB reactor without post-treatment (UASB) and (iii) UASB reactor followed by several post-treatment processes (UASB + POST); (b) predominantly aerobic: (iv) facultative pond (FP), (v) anaerobic pond followed by facultative pond (AP + FP) and (vi) activated sludge (AS). The results, confirmed by statistical tests, showed that, in general, the best performance was achieved by AS, but closely followed by UASB reactor, when operating with any kind of post-treatment. The effluent quality of the anaerobic processes ST + AF and UASB reactor without post-treatment was very similar to the one presented by facultative pond, a simpler aerobic process, regarding organic matter.

  6. The anaerobic threshold: over-valued or under-utilized? A novel concept to enhance lipid optimization!

    PubMed

    Connolly, Declan A J

    2012-09-01

    The purpose of this article is to assess the value of the anaerobic threshold for use in clinical populations with the intent to improve exercise adaptations and outcomes. The anaerobic threshold is generally poorly understood, improperly used, and poorly measured. It is rarely used in clinical settings and often reserved for athletic performance testing. Increased exercise participation within both clinical and other less healthy populations has increased our attention to optimizing exercise outcomes. Of particular interest is the optimization of lipid metabolism during exercise in order to improve numerous conditions such as blood lipid profile, insulin sensitivity and secretion, and weight loss. Numerous authors report on the benefits of appropriate exercise intensity in optimizing outcomes even though regulation of intensity has proved difficult for many. Despite limited use, selected exercise physiology markers have considerable merit in exercise-intensity regulation. The anaerobic threshold, and other markers such as heart rate, may well provide a simple and valuable mechanism for regulating exercising intensity. The use of the anaerobic threshold and accurate target heart rate to regulate exercise intensity is a valuable approach that is under-utilized across populations. The measurement of the anaerobic threshold can be simplified to allow clients to use nonlaboratory measures, for example heart rate, in order to self-regulate exercise intensity and improve outcomes.

  7. Feasibility tests for treating shampoo and hair colorant wastewaters using anaerobic processes.

    PubMed

    Ahammad, Shaikh Z; Yakubu, A; Dolfing, J; Mota, C; Graham, D W

    2012-01-01

    Wastes from the personal care product (PCP) industry are often high in biodegradable carbon, which makes them amenable to aerobic biological treatment, although process costs are usually high due to aeration inefficiencies, high electricity demand and production of large amounts of sludge. As such, anaerobic treatment technologies are being considered to lower net energy costs by reducing air use and increasing methane production. To assess the amenability of PCP wastes to anaerobic treatment, methane yields and rates were quantified in different anaerobic reactors treating typical PCP wastes, including wastes from shampoo and hair colorant products. Overall, shampoo wastes were more amenable to methanogenesis with almost double the methane yields compared with colour wastes. To assess relevant microbial guilds, qPCR was performed on reactor biomass samples. Methanosaetaceae abundances were always significantly higher than Methanosarcinaceae and Methanomicrobiales abundances (P < 0.05), and did not differ significantly between waste types. Although colour wastes were less amenable to anaerobic treatment than shampoo wastes, differences cannot be explained by relative microbial abundances and probably result from the presence of inhibiting compounds in hair colorants (e.g., oxidants) at higher levels. Results showed that anaerobic technologies have great potential for treating PCP wastes, but additional work is needed to establish the basis of elevated methane yields and inhibition, especially when colorant wastes are present.

  8. High-intensity interval training has positive effects on performance in ice hockey players.

    PubMed

    Naimo, M A; de Souza, E O; Wilson, J M; Carpenter, A L; Gilchrist, P; Lowery, R P; Averbuch, B; White, T M; Joy, J

    2015-01-01

    In spite of the well-known benefits that have been shown, few studies have looked at the practical applications of high-intensity interval training (HIIT) on athletic performance. This study investigated the effects of a HIIT program compared to traditional continuous endurance exercise training. 24 hockey players were randomly assigned to either a continuous or high-intensity interval group during a 4-week training program. The interval group (IG) was involved in a periodized HIIT program. The continuous group (CG) performed moderate intensity cycling for 45-60 min at an intensity that was 65% of their calculated heart rate reserve. Body composition, muscle thickness, anaerobic power, and on-ice measures were assessed pre- and post-training. Muscle thickness was significantly greater in IG (p=0.01) when compared to CG. The IG had greater values for both ∆ peak power (p<0.003) and ∆ mean power (p<0.02). Additionally, IG demonstrated a faster ∆ sprint (p<0.02) and a trend (p=0.08) for faster ∆ endurance test time to completion for IG. These results indicate that hockey players may utilize short-term HIIT to elicit positive effects in muscle thickness, power and on-ice performance. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Optimal pacing strategy: from theoretical modelling to reality in 1500-m speed skating.

    PubMed

    Hettinga, F J; De Koning, J J; Schmidt, L J I; Wind, N A C; Macintosh, B R; Foster, C

    2011-01-01

    Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing profile. Seven national-level speed-skaters performed a SP 1500-m which was analysed by obtaining velocity (every 100 m) and body position (every 200 m) with video to calculate total mechanical power output. Together with gross efficiency and aerobic kinetics, obtained in separate trials, data were used to calculate aerobic and anaerobic power output profiles. An energy flow model was applied to SP, simulating a range of pacing strategies, and a theoretically optimal pacing profile was imposed in a second race (IM). Final time for IM was ∼2 s slower than SP. Total power distribution per lap differed, with a higher power over the first 300 m for IM (637.0 (49.4) vs 612.5 (50.0) W). Anaerobic parameters did not differ. The faster first lap resulted in a higher aerodynamic drag coefficient and perhaps a less effective push-off. Experienced athletes have a well-developed performance template, and changing pacing strategy towards a theoretically optimal fast start protocol had negative consequences on speed-skating technique and did not result in better performance.

  10. Time-to-positivity, type of culture media and oxidase test performed on positive blood culture vials to predict Pseudomonas aeruginosa in patients with Gram-negative bacilli bacteraemia.

    PubMed

    Cobos-Triguero, N; Zboromyrska, Y; Morata, L; Alejo, I; De La Calle, C; Vergara, A; Cardozo, C; Arcas, M P; Soriano, A; Marco, F; Mensa, J; Almela, M; Martínez, J A

    2017-02-01

    The aim of this study was to determine the usefulness of oxidase test and time-to-positivity (TTP) in aerobic and anaerobic blood culture vials to detect the presence of Pseudomonas aeruginosa in patients with Gram-negative bacilli (GNB) bacteraemia. TTP was recorded for each aerobic and anaerobic blood culture vial of monomicrobial bacteraemia due to GNB. Oxidase test was performed in a pellet of the centrifuged content of the positive blood culture. An algorithm was developed in order to perform the oxidase test efficiently taking into account TTP and type of vial. A total of 341 episodes of GNB bacteraemia were analysed. Sensitivity, specificity, positive predictive value and negative predictive value of the oxidase test performed on positive vials with GNB to predict P. aeruginosa were 95%, 99%, 91%, and 99%, respectively. When growth was first or exclusively detected in anaerobic vials, P. aeruginosa was never identified hence the performance of the oxidase test could be avoided. When growth was only or first detected in aerobic vials, a TTP≥8h predicted P. aeruginosa in 37% or cases (63 of 169), therefore oxidase test is highly recommended. Oxidase test performed onto positive blood culture vials previously selected by TTP and type of vials is an easy and inexpensive way to predict P. aeruginosa. In most cases, this can lead to optimization of treatment in less than 24 hours.

  11. Evaluation of a pilot-scale sewage biogas powered 2.8 kWe Solid Oxide Fuel Cell: Assessment of heat-to-power ratio and influence of oxygen content

    NASA Astrophysics Data System (ADS)

    de Arespacochaga, N.; Valderrama, C.; Peregrina, C.; Mesa, C.; Bouchy, L.; Cortina, J. L.

    2015-12-01

    Biogas from anaerobic digestion of organic matter is a promising renewable energy source and fuel cells appear as a breakthrough technology to improve the performance of the biogas-to-energy valorisation chain. The vast majority of studies addressing biogas energy recovery through Solid Oxide Fuel Cells published in recent years correspond to simulations and lab-scale performance with synthetic biogas. This paper assesses the pilot performance of a 2.8 kWe SOFC unit powered with cleaned sewage biogas for around 700 h in a Wastewater Treatment Plant. The biogas thorough treatment consisting of a biological desulphurisation with a biotrickling filter followed by a deep cleaning step based on adsorption is successful for removing sulphur compounds, siloxanes and hydrocarbons. The influence of the heat-to-power ratio on fuel cell performance is investigated operating the system at O/C ratio of 2, reforming temperature of 550 °C, stack temperature of 800 °C and at a constant voltage of 43 V. At optimized conditions for electrical production satisfying heat demand in the WWTP, system electrical and thermal efficiencies account for 34% and 28%. Cogeneration efficiency remains constant at around 59-62% for all the heat-to-power ratios tested. Furthermore, the impact of the oxygen content in the biogas is also studied.

  12. Integrating microbial fuel cells with anaerobic acidification and forward osmosis membrane for enhancing bio-electricity and water recovery from low-strength wastewater.

    PubMed

    Liu, Jinmeng; Wang, Xinhua; Wang, Zhiwei; Lu, Yuqin; Li, Xiufen; Ren, Yueping

    2017-03-01

    Microbial fuel cells (MFCs) and forward osmosis (FO) are two emerging technologies with great potential for energy-efficient wastewater treatment. In this study, anaerobic acidification and FO membrane were simultaneously integrated into an air-cathode MFC (AAFO-MFC) for enhancing bio-electricity and water recovery from low-strength wastewater. During a long-term operation of approximately 40 days, the AAFO-MFC system achieved a continuous and relatively stable power generation, and the maximum power density reached 4.38 W/m 3 . The higher bio-electricity production in the AAFO-MFC system was mainly due to the accumulation of ethanol resulted from anaerobic acidification process and the rejection of FO membrane. In addition, a proper salinity environment in the system controlled by the addition of MF membrane enhanced the electricity production. Furthermore, the AAFO-MFC system produced a high quality effluent, with the removal rates of organic matters and total phosphorus of more than 97%. However, the nitrogen removal was limited for the lower rejection of FO membrane. The combined biofouling and inorganic fouling were responsible for the lower water flux of FO membrane, and the Desulfuromonas sp. utilized the ethanol for bio-electricity production was observed in the anode. These results substantially improve the prospects for simultaneous wastewater treatment and energy recovery, and further studies are needed to optimize the system integration and operating parameters. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Identification and antimicrobial susceptibility of obligate anaerobic bacteria from clinical samples of animal origin.

    PubMed

    Mayorga, Melissa; Rodríguez-Cavallini, Evelyn; López-Ureña, Diana; Barquero-Calvo, Elías; Quesada-Gómez, Carlos

    2015-12-01

    The etiology of veterinary infectious diseases has been the focus of considerable research, yet relatively little is known about the causative agents of anaerobic infections. Susceptibility studies have documented the emergence of antimicrobial resistance and indicate distinct differences in resistance patterns related to veterinary hospitals, geographic regions, and antibiotic-prescribing regimens. The aim of the present study was to identify the obligate anaerobic bacteria from veterinary clinical samples and to determinate the in vitro susceptibility to eight antimicrobials and their resistance-associated genes. 81 clinical specimens obtained from food-producing animals, pets and wild animals were examined to determine the relative prevalence of obligate anaerobic bacteria, and the species represented. Bacteroides spp, Prevotella spp and Clostridium spp represented approximately 80% of all anaerobic isolates. Resistance to metronidazole, clindamycin, tetracycline and fluoroquinolones was found in strains isolated from food-producing animals. Ciprofloxacin, enrofloxacin and cephalotin showed the highest resistance in all isolates. In 17%, 4% and 14% of tetracycline-resistant isolates, the resistance genes tetL, tetM and tetW were respectively amplified by PCR whereas in 4% of clindamycin-resistant strains the ermG gene was detected. 26% of the isolates were positive for cepA, while only 6% harbored the cfxA (resistance-conferring genes to beta-lactams). In this study, the obligate anaerobic bacteria from Costa Rica showed a high degree of resistance to most antimicrobials tested. Nevertheless, in the majority of cases this resistance was not related to the resistance acquired genes usually described in anaerobes. It is important to address and regulate the use of antimicrobials in the agricultural industry and the empirical therapy in anaerobic bacterial infections in veterinary medicine, especially since antibiotics and resistant bacteria can persist in the environment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Prognostic value of indeterminable anaerobic threshold in heart failure.

    PubMed

    Agostoni, Piergiuseppe; Corrà, Ugo; Cattadori, Gaia; Veglia, Fabrizio; Battaia, Elisa; La Gioia, Rocco; Scardovi, Angela B; Emdin, Michele; Metra, Marco; Sinagra, Gianfranco; Limongelli, Giuseppe; Raimondo, Rosa; Re, Federica; Guazzi, Marco; Belardinelli, Romualdo; Parati, Gianfranco; Magrì, Damiano; Fiorentini, Cesare; Cicoira, Mariantonietta; Salvioni, Elisabetta; Giovannardi, Marta; Mezzani, Alessandro; Scrutinio, Domenico; Di Lenarda, Andrea; Mantegazza, Valentina; Ricci, Roberto; Apostolo, Anna; Iorio, Annamaria; Paolillo, Stefania; Palermo, Pietro; Contini, Mauro; Vassanelli, Corrado; Passino, Claudio; Piepoli, Massimo F

    2013-09-01

    In patients with heart failure (HF), during maximal cardiopulmonary exercise test, anaerobic threshold (AT) is not always identified. We evaluated whether this finding has a prognostic meaning. We recruited and prospectively followed up, in 14 dedicated HF units, 3058 patients with systolic (left ventricular ejection fraction <40%) HF in stable clinical conditions, New York Heart Association class I to III, who underwent clinical, laboratory, echocardiographic, and cardiopulmonary exercise test investigations at study enrollment. We excluded 921 patients who did not perform a maximal exercise, based on lack of achievement of anaerobic metabolism (peak respiratory quotient ≤1.05). Primary study end point was a composite of cardiovascular death and urgent cardiac transplant, and secondary end point was all-cause death. Median follow-up was 3.01 (1.39-4.98) years. AT was identified in 1935 out of 2137 patients (90.54%). At multivariable logistic analysis, failure in detecting AT resulted significantly in reduced peak oxygen uptake and higher metabolic exercise and cardiac and kidney index score value, a powerful prognostic composite HF index (P<0.001). At multivariable analysis, the following variables were significantly associated with primary study end point: peak oxygen uptake (% pred; P<0.001; hazard ratio [HR]=0.977; confidence interval [CI]=0.97-0.98), ventilatory efficiency slope (P=0.01; HR=1.02; CI=1.01-1.03), hemoglobin (P<0.05; HR=0.931; CI=0.87-1.00), left ventricular ejection fraction (P<0.001; HR=0.948; CI=0.94-0.96), renal function (modification of diet in renal disease; P<0.001; HR=0.990; CI=0.98-0.99), sodium (P<0.05; HR=0.967; CI=0.94-0.99), and AT nonidentification (P<0.05; HR=1.41; CI=1.06-1.89). Nonidentification of AT remained associated to prognosis also when compared with metabolic exercise and cardiac and kidney index score (P<0.01; HR=1.459; CI=1.09-1.10). Similar results were obtained for the secondary study end point. The inability to identify AT most often occurs in patients with severe HF, and it has an independent prognostic role in HF.

  15. Rapid spot test for the determination of esculin hydrolysis.

    PubMed

    Edberg, S C; Gam, K; Bottenbley, C J; Singer, J M

    1976-08-01

    Esculin hydrolysis is a useful test in the differentiation of both gram-positive and gram-negative bacteria covering a wide spectrum of aerobes, facultative anaerobes, and anaerobes. Commonly utilized methods require a minimum of 18 h of incubation in broth or agar medium and utilize the production of a brown-black compound, due to the combination of ferric ions with the hydrolysis product esculetin, as indicator. A procedure is presented that requires 15 to 30 min for completion and utilizes fluorescence loss as the indicator of hydrolysis. Esculin fluoresces at 366 nm, whereas the hydrolysis product esculetin does not. Over 1,400 strains of gram-positive and gram-negative bacteria were tested. There was 98.4% of correlation between the spot test and esculin broth and 97% correlation with the bile-esculin agar.

  16. A Novel Electrophototrophic Bacterium Rhodopseudomonas palustris Strain RP2, Exhibits Hydrocarbonoclastic Potential in Anaerobic Environments

    PubMed Central

    Venkidusamy, Krishnaveni; Megharaj, Mallavarapu

    2016-01-01

    An electrophototrophic, hydrocarbonoclastic bacterium Rhodopseudomonas palustris stain RP2 was isolated from the anodic biofilms of hydrocarbon fed microbial electrochemical remediation systems (MERS). Salient properties of the strain RP2 were direct electrode respiration, dissimilatory metal oxide reduction, spore formation, anaerobic nitrate reduction, free living diazotrophy and the ability to degrade n-alkane components of petroleum hydrocarbons (PH) in anoxic, photic environments. In acetate fed microbial electrochemical cells, a maximum current density of 305 ± 10 mA/m2 (1000Ω) was generated (power density 131.65 ± 10 mW/m2) by strain RP2 with a coulombic efficiency of 46.7 ± 1.3%. Cyclic voltammetry studies showed that anaerobically grown cells of strain RP2 is electrochemically active and likely to transfer electrons extracellularly to solid electron acceptors through membrane bound compounds, however, aerobically grown cells lacked the electrochemical activity. The ability of strain RP2 to produce current (maximum current density 21 ± 3 mA/m2; power density 720 ± 7 μW/m2, 1000 Ω) using PH as a sole energy source was also examined using an initial concentration of 800 mg l-1 of diesel range hydrocarbons (C9-C36) with a concomitant removal of 47.4 ± 2.7% hydrocarbons in MERS. Here, we also report the first study that shows an initial evidence for the existence of a hydrocarbonoclastic behavior in the strain RP2 when grown in different electron accepting and illuminated conditions (anaerobic and MERS degradation). Such observations reveal the importance of photoorganotrophic growth in the utilization of hydrocarbons from contaminated environments. Identification of such novel petrochemical hydrocarbon degrading electricigens, not only expands the knowledge on the range of bacteria known for the hydrocarbon bioremediation but also shows a biotechnological potential that goes well beyond its applications to MERS. PMID:27462307

  17. Activity of OPT-80, a novel macrocycle, compared with those of eight other agents against selected anaerobic species.

    PubMed

    Credito, Kim L; Appelbaum, Peter C

    2004-11-01

    Agar dilution MIC was used to compare activities of OPT-80, linezolid, vancomycin, teicoplanin, quinupristin/dalfopristin, amoxicillin/clavulanate, imipenem, clindamycin, and metronidazole against 350 gram-positive and -negative anaerobes. OPT-80 was active against gram-positive strains only, especially Clostridium spp. (85 strains tested, including 21 strains of C. difficile), with MICs ranging between

  18. Evaluation of Upland Disposal of Richmond Harbor, California, Sediment from Santa Fe Channel

    DTIC Science & Technology

    1993-07-01

    15 concern were salt, metals, tributyltin ( TBT ), pesticides (particularly DDT and its derivatives), and polycyclic aromatic hydrocarbons (PAHs). Test...Battelle Northwest for tetrabutyltin (TETBT), tributyltin ( TBT ), dibutyltin (DBT), monobutyltin (MBT), naphthalene, acenaphthylene, acenaphthene...RANK TBT D1-1 t Richmond, Anaerobic, Kinetic, Tributyltin , day 1, Rep 1 RANS PAN D5-3 : Richmond, Anaerobic, Sequential, PAHs, day 5, Rep 3. RO-14-5

  19. Effects of movement and work load in patients with congenital central hypoventilation syndrome.

    PubMed

    Hager, Alfred; Koch, Walter; Stenzel, Heike; Hess, John; Schöber, Johannes

    2007-04-01

    Patients with congenital central hypoventilation syndrome lack ventilatory chemosensitivity and depend at least in part on the ergoreceptor function during exercise. In these patients a substantial increase of ventilation has been reported for passive movement during sleep as well as active movement on a treadmill. The aim of the study was to investigate ventilatory response to an increasing work load with constant movement. Eighteen patients and 17 healthy volunteers performed a cardiopulmonary exercise test on a bicycle pedaling at a constant rate of about 60 revolutions per minute throughout the entire test. The patients were able to exercise adequately and showed normal peak oxygen uptake. There was a steep rise in minute ventilation in both groups at the start of exercise, yet there was only a minor increase in both groups during the increase of workload up to the anaerobic threshold. After the anaerobic threshold, there was again an increase in ventilation in both groups, but the increase was less prominent in the patient group. Ventilation in patients with congenital central hypoventilation syndrome is increased during exercise caused both by movement (mechanoreceptors) and by anaerobic workload. This facilitates a normal ventilatory drive up to the anaerobic threshold and a normal exercise capacity in these patients.

  20. Improvement in exercise capacity and delayed anaerobic metabolism induced by far-infrared-emitting garments in active healthy subjects: A pilot study.

    PubMed

    Mantegazza, Valentina; Contini, Mauro; Botti, Maurizia; Ferri, Ada; Dotti, Francesca; Berardi, Pierluigi; Agostoni, Piergiuseppe

    2018-01-01

    Background Far-infrared-emitting garments have several biological properties including the capability to increase blood perfusion in irradiated tissues. Design The aim of the study was to evaluate whether far-infrared radiation increases exercise capacity and delays anaerobic metabolism in healthy subjects. Methods With a double-blind, crossover protocol, a maximal cardiopulmonary exercise test was performed in 20 volunteers, wearing far-infrared or common sport clothes, identical in texture and colour. Results Comparing far-infrared with placebo garments, higher oxygen uptake at peak of exercise and longer endurance time were observed (peak oxygen uptake 38.0 ± 8.9 vs. 36.2 ± 8.5 ml/kg/min, endurance time 592 ± 85 vs. 570 ± 71 seconds; P < 0.01); the anaerobic threshold was significantly delayed (anaerobic threshold time 461 ± 93 vs. 417 ± 103 seconds) and anaerobic threshold oxygen uptake and anaerobic threshold oxygen pulse were significantly higher (25.3 ± 6.4 vs. 20.9 ± 5.4 ml/kg/min and 13.3 ± 3.8 vs. 12.4 ± 3.3 ml/beat, respectively). In 10 subjects the blood lactate concentration was measured every 2 minutes during exercise and at peak; lower values were observed with far-infrared fabrics compared to placebo from the eighth minute of exercise, reaching a significant difference at 10 minutes (3.6 ± 0.83 vs. 4.4 ± 0.96 mmol/l; P = 0.02). Conclusions In healthy subjects, exercising with a far-infrared outfit is associated with an improvement in exercise performance and a delay in anaerobic metabolism. In consideration of the acknowledged non-thermic properties of functionalised clothes, these effects could be mediated by an increase in oxygen peripheral delivery secondary to muscular vasodilation. These data suggest the need for testing far-infrared-emitting garments in patients with exercise limitation or in chronic cardiovascular and respiratory patients engaged in rehabilitation programmes.

Top